WorldWideScience

Sample records for air conditioning

  1. REACH. Air Conditioning Units.

    Science.gov (United States)

    Garrison, Joe; And Others

    As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of air conditioning. The instructional units focus on air conditioning fundamentals, window air conditioning, system and installation, troubleshooting and…

  2. Air Conditioning Does Reduce Air Pollution Indoors

    Science.gov (United States)

    Healy, Bud

    1970-01-01

    Report of the winter meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. Subjects covered are--(1) title subject, (2) predictions for the human habitat in 1994, (3) fans, and (4) fire safety in buildings. (JW)

  3. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  4. Flow in air conditioned rooms

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    1974-01-01

    Flow in air conditioned r ooms is examined by means of model experiments . The different gearnetries giving unsteady, steady three- dimensional and steady twodimensional flow are determined . Velacity profiles and temperature profiles are measured in some of the geometries. A numerical solution...... of the flow equations is demonstrated and the flow in air conditioned rooms in case of steady two dimensional flow is predi cted. Compari son with measured results is shown i n the case of small Archimedes numbers, and predictions are shown at high Archimedes numbers. A numerical prediction of f low and heat...

  5. Ventilation-air conditioning system

    International Nuclear Information System (INIS)

    Heretofore, in ventilation-air conditioning systems in a nuclear power plant, exhaust gases from each of the ventilation-air conditioning systems of a reactor building, a turbine building, a waste processing building are joined and they are released into atmosphere from the top of a high main exhaustion stack. In order to build such a high main exhaustion stack, a considerable construction cost is required and, in addition, there is a worry of lacking balance with surrounding scenery. Then, in the present invention, exhaust gases are heated by waste heat in a turbine during their introduction from the ventilation-air conditioning facility in the building of a power plant to the main exhaust stack. With such a constitution, since the exhaust gases are heated and their temperature is elevated, they uprise by natural convection when they are released from the top of the main exhaustion stack to the atmosphere. Accordingly, they are released to a level higher than the conventional case in view of the volume of the blower which sends the exhaust gases under pressure, to diffuse them to the atmosphere more sufficiently compared with a conventional case. Further, the height of the main exhaustion stack can be reduced, enabling to minimize the cost for moving the blower. (T.M.)

  6. Solar air-conditioning. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    Within the 3rd International Conference on solar air-conditioning in Palermo (Italy) at 30th September to 2nd October, 2009 the following lectures were held: (1) Removal of non-technological barriers to solar cooling technology across Southern European islands (Stefano Rugginenti); (2) The added economic and environmental value of solar thermal systems in microgrids with combined heat and power (Chris Marney); (3) Australian solar cooling interest group (Paul Kohlenbach); (4) Designing of a technology roadmap for solar assisted air conditioning in Austria (Hilbert Focke); (5) Solar cooling in the new context of renewable policies at European level (Raffaele Piria); (6) Prototype of a solar driven steam jet ejector chiller (Clemens Pollerberg); (7) New integrated solar air conditioning system (Joan Carlos Bruno); (8) Primary energy optimised operation of solar driven desiccant evaporative cooling systems through innovative control strategies; (9) Green chiller association (Uli Jakob); (10) Climate Well {sup registered} (Olof Hallstrom); (11) Low capacity absorption chillers for solar cooling applications (Gregor Weidner); (12) Solar cooling in residential, small scale commercial and industrial applications with adsorption technology (Walter Mittelbach); (13) French solar heating and cooling development programme based on energy performance (Daniel Mugnier); (14) Mirrox fresnel process heat collectors for industrial applications and solar cooling (Christian Zahler); (15) Modelling and analyzing solar cooling systems in polysun (Seyen Hossein Rezaei); (16) Solar cooling application in Valle Susa Italy (Sufia Jung); (17) Virtual case study on small solar cooling systems within the SolarCombi+Project (Bjoern Nienborg); (18) Design of solar cooling plants under uncertainty (Fernando Dominguez-Munoz); (19) Fast pre-design of systems using solar thermally driven chillers (Hans-Martin Henning); (20) Design of a high fraction solar heating and cooling plant in southern

  7. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  8. HEATING AND AIR CONDITIONING EDUCATIONAL PROGRAM.

    Science.gov (United States)

    Lennox Industries, Inc., Marshalltown, IA.

    INCREASED MOTIVATION, INCREASED INITIAL COMPREHENSION, AND INCREASED RETENTION ARE THE PRIME GOALS OF THE LENNOX HEATING AND AIR CONDITIONING EDUCATION PROGRAM. IT IS A COMPLETE PROGRAM WITH ALL THE TEACHING TOOLS REQUIRED TO PRODUCE A KNOWLEDGEABLE HEATING AND AIR-CONDITIONING INSTALLER OR SERVICE MAN. THIS INSTRUCTIONAL PROGRAM IS DESIGNED…

  9. Air Conditioning. Performance Objectives. Intermediate Course.

    Science.gov (United States)

    Long, William

    Several intermediate performance objectives and corresponding criterion measures are listed for each of seven terminal objectives for an intermediate air conditioning course. The titles of the seven terminal objectives are Refrigeration Cycle, Job Requirement Skills, Air Conditioning, Trouble Shooting, Performance Test, Shop Management, and S.I.E.…

  10. Carbon Emissions from air-Conditioning

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2013-01-01

    Full Text Available This paper explores electricity consumption and carbon emissions associated with air-conditioning. The total heat load of a room fitted with air conditioner of 1.5 ton capacity has been calculated by calculating conduction and ventilation losses. Solar heat gain and internal gain were taken as the other two parameters for the total heat calculation.

  11. Air conditioning for data processing system areas

    Directory of Open Access Journals (Sweden)

    Hernando Camacho García

    2011-06-01

    Full Text Available The appropiate selection of air conditioners for data processing system areas requires the knowledge of the environmental desing conditions, the air conditioning systems succssfully used computer and the cooling loads to handle. This work contains information about a wide variety of systems designed for computer room applications. a complete example of calculation to determine the amount of heat to be removed for satisfactory operation, is also included.

  12. Reduced bleed air extraction for DC-10 cabin air conditioning

    Science.gov (United States)

    Newman, W. H.; Viele, M. R.; Hrach, F. J.

    1980-01-01

    It is noted that a significant fuel savings can be achieved by reducing bleed air used for cabin air conditioning. Air in the cabin can be recirculated to maintain comfortable ventilation rates but the quality of the air tends to decrease due to entrainment of smoke and odors. Attention is given to a development system designed and fabricated under the NASA Engine Component Improvement Program to define the recirculation limit for the DC-10. It is shown that with the system, a wide range of bleed air reductions and recirculation rates is possible. A goal of 0.8% fuel savings has been achieved which results from a 50% reduction in bleed extraction from the engine.

  13. Heating, ventilation and air conditioning system modelling

    Energy Technology Data Exchange (ETDEWEB)

    Whalley, R.; Abdul-Ameer, A. [British University in Dubai (United Arab Emirates)

    2011-03-15

    Heating, ventilation and air conditioning modelling methods, for large scale, spatially dispersed systems are considered. Existing techniques are discussed and proposals for the application of novel analysis approaches are outlined. The use of distributed-lumped parameter procedures enabling the incorporation of the relatively concentrated and significantly dispersed, system element characteristics, is advocated. A dynamic model for a heating, ventilation and air conditioning system comprising inlet and exhaust fans, with air recirculation, heating/cooling and filtration units is presented. Pressure, airflow and temperature predictions within the system are computed following input, disturbance changes and purging operations. The generalised modelling advancements adopted and the applicability of the model for heating, ventilation and air conditioning system simulation, re-configuration and diagnostics is emphasised. The employment of the model for automatic, multivariable controller design purposes is commented upon. (author)

  14. Smart Sensors Enable Smart Air Conditioning Control

    OpenAIRE

    Chin-Chi Cheng; Dasheng Lee

    2014-01-01

    In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants’ information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans’ intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be contr...

  15. Thermal analysis of car air conditioning

    Science.gov (United States)

    Trzebiński, Daniel; Szczygieł, Ireneusz

    2010-10-01

    Thermodynamic analysis of car air cooler is presented in this paper. Typical refrigerator cycles are studied. The first: with uncontrolled orifice and non controlled compressor and the second one with the thermostatic controlled expansion valve and externally controlled compressor. The influence of the refrigerant decrease and the change of the air temperature which gets to exchangers on the refrigeration efficiency of the system; was analysed. Also, its effectiveness and the power required to drive the compressor were investigated. The impact of improper refrigerant charge on the performance of air conditioning systems was also checked.

  16. ALTERNATIVE TECHNOLOGIES FOR REFRIGERATION AND AIR-CONDITIONING APPLICATIONS

    Science.gov (United States)

    The report gives results of an assessment of refrigeration technologies that are alternatives to vapor compression refrigeration for use in five application categories: domestic air conditioning, commercial air conditioning, mobile air conditioning, domestic refrigeration, and co...

  17. Air Conditioning and Refrigeration Book IV.

    Science.gov (United States)

    Eckes, William; Fulkerson, Dan

    This publication is the concluding text in a four-part curriculum for air conditioning and refrigeration. Materials in Book 4 are designed to complement theoretical and functional elements in Books 1-3. Instructional materials in this publication are written in terms of student performance using measurable objectives. The course includes six…

  18. Fundamentals of Air Conditioning and Refrigeration.

    Science.gov (United States)

    Clemons, Mark

    This set of instructional materials provides secondary and postsecondary students with a state-of-the-art curriculum for the air conditioning and refrigeration industry that includes the many changes brought by new Environmental Protection Agency (EPA) regulations. Introductory materials explain the use of this publication and provide the…

  19. Air Conditioning and Refrigeration Supplementary Units.

    Science.gov (United States)

    Winston, Del; And Others

    This document contains supplemental materials for special needs high school students intended to facilitate their mainstreaming in regular air conditioning and refrigeration courses. Teacher's materials precede the materials for students and include general notes for the instructor, additional suggestions, two references, a questionnaire on the…

  20. Air Conditioning and Refrigeration. Book Two.

    Science.gov (United States)

    Wantiez, Gary W.

    This curriculum guide (book II), along with book I, is designed to provide students with the basic skills for an occupation in air conditioning and refrigeration. Six major areas are included, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Electricity (fundamentals of electricity,…

  1. Readings in Air Conditioning and Refrigeration.

    Science.gov (United States)

    Uberto, Jeffrey A.

    Designed to encourage vocational high school students to read by offering reading materials relevant to their vocational goals, this document contains thirty-seven articles related to air conditioning and refrigeration which have been selected from trade journals, magazines, and newspapers and adapted to the students' reading capabilities. A…

  2. Air Conditioning and Refrigeration. Book One.

    Science.gov (United States)

    Wantiez, Gary W.

    Designed to provide students with the basic skills for an occupation in air conditioning and refrigeration, this curriculum guide includes seven major areas, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Orientation (history and development, and job opportunities), Safety…

  3. Thermal conditions and perceived air quality in an air-conditioned auditorium

    Science.gov (United States)

    Polednik, Bernard; Guz, Łukasz; Skwarczyński, Mariusz; Dudzińska, Marzenna R.

    2016-07-01

    The study reports measurements of indoor air temperature (T) and relative humidity (RH), perceived air quality (PAQ) and CO2, fine aerosol particle number (PN) and mass (PM1) concentrations in an air conditioned auditorium. The measurements of these air physical parameters have been carried out in the unoccupied auditorium with the air conditioning system switched off (AC off mode) and in the unoccupied and occupied auditorium with the air conditioning system switched off during the night and switched on during the day (AC on/off mode). The average indoor air thermal parameters, CO2 concentration and the PAQ value (in decipols) were elevated, while average PM1 concentration was lower in the AC on/off mode. A statistically significant (p r = 0.66 and r = 0.59, respectively) in that AC mode. A significant negative correlation has been observed between T and PN and PM1 concentrations (r = -0.38 and r = -0.49, respectively). In the AC off mode the above relations between T and the particle concentrations were not that unequivocal. These findings may be of importance as they indicate that in certain AC operation modes the indoor air quality deteriorates along with the variation of the indoor air microclimate and room occupation. This, in turn, may adversely affect the comfort and productivity of the users of air conditioned premises.

  4. Smart sensors enable smart air conditioning control.

    Science.gov (United States)

    Cheng, Chin-Chi; Lee, Dasheng

    2014-01-01

    In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants' information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans' intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be controlled accurately with errors of less than ±0.1 °C. Rapid cool down can be achieved within 2 min to the optimized indoor capacity after occupants enter a room. It's also noted that within two-hour operation the total compressor output of the smart air conditioner is 48.4% less than that of the one using On-Off control. The smart air conditioner with wearable devices could detect the human temperature and activity during sleep to determine the sleeping state and adjusting the sleeping function flexibly. The sleeping function optimized by the smart air conditioner with wearable devices could reduce the energy consumption up to 46.9% and keep the human health. The presented smart air conditioner could provide a comfortable environment and achieve the goals of energy conservation and environmental protection. PMID:24961213

  5. Smart Sensors Enable Smart Air Conditioning Control

    Directory of Open Access Journals (Sweden)

    Chin-Chi Cheng

    2014-06-01

    Full Text Available In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants’ information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans’ intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be controlled accurately with errors of less than ±0.1 °C. Rapid cool down can be achieved within 2 min to the optimized indoor capacity after occupants enter a room. It’s also noted that within two-hour operation the total compressor output of the smart air conditioner is 48.4% less than that of the one using On-Off control. The smart air conditioner with wearable devices could detect the human temperature and activity during sleep to determine the sleeping state and adjusting the sleeping function flexibly. The sleeping function optimized by the smart air conditioner with wearable devices could reduce the energy consumption up to 46.9% and keep the human health. The presented smart air conditioner could provide a comfortable environment and achieve the goals of energy conservation and environmental protection.

  6. Air Conditioning System using Rankine Cycle

    Science.gov (United States)

    Nagatomo, Shigemi; Yamaguchi, Hiroichi; Hattori, Hitoshi; Futamura, Motonori

    Natural gas is used as the energy source to cope with the recent situation of increasing demand for electricity especially in summer. In this paper, the performance of a Rankine cycle air conditioning system driven by natural gas was studied. The following results were obtained : (1) Basic equations of performance, refrigerant mass flow rate and expander volume were developed by using the values of heating efficiency, regeneration efficiency, expander efficiency and compressor efficiency. (2) R134a refrigerant has been considered to be suitable for the Rankine cycle air conditioning system, compared with other refrigerants. (3)A Rankine cycle cooling system using R134a refrigerant as a single working fluid was developed. System COP of 0.47 was attained at typical operating condition.

  7. Evaporative Condensers in Comfortable Air Conditioning System

    Institute of Scientific and Technical Information of China (English)

    YIN Ying-de; ZHU Dong-sheng; DU Gui-mei; LI Yuan-xi; SUN He-jing; LIU Qing-ming

    2009-01-01

    The operating theory of an evaporative condenser was expatiated.The difference between an e-vaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative con-densers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative con-densing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected.

  8. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    OpenAIRE

    Pookongchai Kritsada; Nakornrat Prasit; Sookananta Bongkoj; Buasri Panhathai

    2015-01-01

    This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point...

  9. Innovative Air Conditioning and Climate Control

    Science.gov (United States)

    Graf, John

    2015-01-01

    NASA needed to develop a desiccant wheel based humidity removal system to enable the long term testing of the Orion CO2 scrubber on the International Space Station. In the course of developing that system, we learned three things that are relevant to energy efficient air conditioning of office towers. NASA developed a conceptual design for a humidity removal system for an office tower environment. We are looking for interested partners to prototype and field test this concept.

  10. Low Energy Air Conditioning for Hot Climates

    OpenAIRE

    Almutairi, Hamad Hhn

    2012-01-01

    Fossil fuels are the major sources of electrical power generation in the world. Among all fossil fuels, oil is considered as the most sought-after fuel. The burden on countries that provide subsidized electricity produced from oil-fired power plants is noteworthy. Kuwait is a notable example of these countries. Electricity in Kuwait is heavily consumed by residential air conditioning, which comprises 60% of the total electricity generated at peak times on a hot summer day. From this perspecti...

  11. Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.

    2013-02-01

    This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

  12. Alternative non-CFC mobile air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Mei, V.C.; Chen, F.C.; Kyle, D.M.

    1992-09-01

    Concern about the destruction of the global environment by chlorofluorocarbon (CFC) fluids has become an impetus in the search for alternative, non-CFC refrigerants and cooling methods for mobile air conditioning (MAC). While some alternative refrigerants have been identified, they are not considered a lasting solution because of their high global warming potential, which could result in their eventual phaseout. In view of this dilemma, environmentally acceptable alternative cooling methods have become important. This report, therefore, is aimed mainly at the study of alternative automotive cooling methodologies, although it briefly discusses the current status of alternative refrigerants. The alternative MACs can be divided into work-actuated and heat-actuated systems. Work-actuated systems include conventional MAC, reversed Brayton air cycle, rotary vane compressor air cycle, Stirling cycle, thermoelectric (TE) cooling, etc. Heat-actuated MACs include metal hydride cooling, adsorption cooling, ejector cooling, absorption cycle, etc. While we are better experienced with some work-actuated cycle systems, heat-actuated cycle systems have a high potential for energy savings with possible waste heat applications. In this study, each altemative cooling method is discussed for its advantages and its limits.

  13. Air cleaning system isolation during tornado conditions

    International Nuclear Information System (INIS)

    The occurrence of a tornado at the site of an operating nuclear power generating station creates unstable atmospheric conditions which can be detrimental to the proper operation of the plant air cleaning system. One means of mitigating or preventing this hazard is isolation of the system from the unstable environment by closure of the system openings during the unstable conditions. For maximum system protection the closure should be an automatic response to the adverse conditions themselves, without reliance on manual or remote sensing or signals. The interaction of tornado characteristics with velocity/pressure sensitive isolation devices is modeled. Force and time relationships are investigated to evaluate and predict the interaction. Laboratory test apparatus is developed for simulating the flows and pressures induced by the tornado at system openings. Several isolation devices of various sizes are subjected to a range of simulated tornado conditions for observation and evaluation of response time, sensitivity, and dyamic closing forces. The model, apparatus, experimentation, and results are presented

  14. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

    International Nuclear Information System (INIS)

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO2) and sulfur dioxide (SO2). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM10, TBC, CO and NO2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM10 and TBC. The elevated PM10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m3, and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m3, which was above the HKIAQO standard of 1000 CFU/m3. The bacteria levels at other three stalls were all below the HKIAQO standard. Statistical

  15. Refrigeration, Heating & Air Conditioning. Post Secondary Curriculum Guide.

    Science.gov (United States)

    Garrison, Joe C.; And Others

    This curriculum guide was designed for use in postsecondary refrigeration, heating and air conditioning education programs in Georgia. Its purpose is to provide for the development of entry level skills in refrigeration, heating, and air conditioning in the areas of air conditioning knowledge, theoretical structure, tool usage, diagnostic ability,…

  16. Computer Model to Estimate Reliability Engineering for Air Conditioning Systems

    International Nuclear Information System (INIS)

    Reliability engineering is used to predict the performance and optimize design and maintenance of air conditioning systems. Air conditioning systems are expose to a number of failures. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely can be due to a variety of problems with one or more components of an air conditioner or air conditioning system. Forecasting for system failure rates are very important for maintenance. This paper focused on the reliability of the air conditioning systems. Statistical distributions that were commonly applied in reliability settings: the standard (2 parameter) Weibull and Gamma distributions. After distributions parameters had been estimated, reliability estimations and predictions were used for evaluations. To evaluate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several The company's departments. This air conditioning system is divided into two, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40-45 degree F (4-7 degree C). The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, this is due to the Weibull and Gamma distributions indicated that the reliability for the systems equal to 86.012% and 77.7% respectively. A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families was studied. It was found that Weibull method performed for decision making.

  17. On the history of air conditioning; Zur Geschichte der Raumklimatechnik

    Energy Technology Data Exchange (ETDEWEB)

    Fitzner, Klaus; Finke, Ulrich [Klimakonzept Ingenieurgesellschaft, Berlin (Germany)

    2010-01-15

    The theoretical bases of indoor air conditioning originates from the time of enlightenment (Lavoisier 1792). For the first time air conditioning is applied 1836 in the House of Commons in London. Wide application begins in the USA in the 1930s, in Germany due to the war after the 1950s. Starting from 1970 there are advancements in Germany and Northern Europe, which make it possible not to only air-condition but to fulfil thermally comfortable conditions. (orig.)

  18. PROSPECTS FOR THE DEVELOPMENT OF TECHNOLOGY AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    O. V. Chernyshova

    2008-03-01

    Full Text Available In the article the evaporation cooling and spray (aqueous and air-to-water types of the air-conditioning systems are considered, their merits and demerits are analyzed; the new scheme of a conditioner is offered.

  19. Air Conditioner Charging. Automotive Mechanics. Air Conditioning. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automobile air conditioning, consists of a student guide and an instructor guide dealing with air conditioning charging. Covered in the module are checking the air conditioning system for leaks, checking and adding refrigerant oil as needed, evacuating the system,…

  20. Siamese twins. [Relationship between lighting and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Bauschke, P.

    1981-01-01

    The paper investigates the connection between lighting and air-conditioning technics. For the engineer planning an air-conditioning plant it is a must to find out the heat produced by the lighting in a room and to include it in his calculation of the air-conditioning plant. This means cooling in summer and using the thermal energy of lighting for heating purposes in winter.

  1. DESIGN a solar hybrid air conditioning compressor system

    OpenAIRE

    Khalaji Assadi M.; Gilani S. I.; Jun Yen T. C.

    2016-01-01

    To develop and integrate solar hybrid system into conventional air conditioning system which provides the same cooling load with considerably less electricity demand. Solar evacuated tube and DC compressor are used for compressing the refrigerant in an air conditioning system, thus effectively reducing the air conditioning electricity consumption by up to 45%. For the flow through type selected geometry of the designed evacuated U-tube collector, a three dimensional simulation and analysis of...

  2. Vibration Analysis of Air Condition Unit on Subway

    Directory of Open Access Journals (Sweden)

    Yan Liu

    2013-06-01

    Full Text Available Subway system has many merits including large passenger carrying ability, high speed, strong controllability and reliability of driving. Nevertheless, subways also have brought many disadvantages for human. In many subway systems, noisy environments are clearly observed and passengers are exposed to higher noise levels than permissible limit. This study presents a study of noise and vibration of subway air condition system, so as to grasp the vibration distribution laws of the air condition system. By the tested of noise and vibration, the researcher find the sound distribution rule of air condition is very important Based on the consequence of the testing, the acceleration of air condition has little to do with the subway speed and more to do with the vibration of fan; When the train driving on the viaduct bridge, the acceleration of air condition is biggish in 125 Hz and In 50-1000 Hz the vibration of air condition is obviously. When the train running underground line, as a result of the resonance of body, air condition’s vibration is biggish in 630 Hz and the vibration is obviously in 125-1250 Hz. With the increase of the speed, the influence of the ground’s second radiation on body vibration is enhanced. The superfine gross wool which is used to air condition can achieve good results for noise reduction. This research has higher reference for the vibration and noise reduction of the subway air condition system.

  3. 2014 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    The proceedings of the 2014 German refrigeration and air conditioning meeting contain contributions on the following topics: cryotechnology, fundamentals and materials for the refrigeration and heat pump technology, devices and components for the refrigeration and heat pump technology, applications of refrigeration technologies, air conditioning technology and heat pump applications, cryotechnology in biology and medicine, heat transfer and ventilation, guidelines and legal topics, refrigerant fluid - oil mixtures, control and surveillance, simulation and control, ambient air.

  4. 2013 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    These proceedings cover the following main topics: cryoengineering - superconduction / energy storage; cryoapplications in biology and medicine; metrology; adsorption processes; condensation/evaporation; working fluids / simulation; ice production; plants and compressors; expansion and ejectors or recooling; use of cooling (passenger car air conditioning, supermarket); refrigerants; plant efficiency; emissions and legislation; air conditioning and use of heat pumps; air quality and control; building technology and block-type thermal power stations.

  5. 2015 German refrigeration and air conditioning meeting. Abstracts

    International Nuclear Information System (INIS)

    The volume contains the abstracts of the 2015 German refrigeration and air conditioning meeting in 5 chapters: cryo-technology, fundamentals of materials for refrigeration engineering and heat pump technology, facilities and components for the refrigeration and heat pump technology; application of refrigeration engineering; air conditioning technology and heat pump application.

  6. DEVELOPMENT OF NEURO FUZZY CONTROLLER ALGORITHM FOR AIR CONDITIONING SYSTEM

    OpenAIRE

    AMRIT KAUR; ARSHDEEP KAUR

    2012-01-01

    The paper presents the neuro-fuzzy controller algorithm for air conditioning system. Neuro-fuzzy control combines the learning capabilities of neural networks and control capabilities of fuzzy logic control. The neurofuzzy controller for air conditioning system takes two inputs from temperature and humidity sensors and controls the compressor speed. The experimental results of the developed system are also shown.

  7. DEVELOPMENT OF NEURO FUZZY CONTROLLER ALGORITHM FOR AIR CONDITIONING SYSTEM

    Directory of Open Access Journals (Sweden)

    AMRIT KAUR

    2012-04-01

    Full Text Available The paper presents the neuro-fuzzy controller algorithm for air conditioning system. Neuro-fuzzy control combines the learning capabilities of neural networks and control capabilities of fuzzy logic control. The neurofuzzy controller for air conditioning system takes two inputs from temperature and humidity sensors and controls the compressor speed. The experimental results of the developed system are also shown.

  8. Thermal Environment for Classrooms. Central System Approach to Air Conditioning.

    Science.gov (United States)

    Triechler, Walter W.

    This speech compares the air conditioning requirements of high-rise office buildings with those of large centralized school complexes. A description of one particular air conditioning system provides information about the system's arrangement, functions, performance efficiency, and cost effectiveness. (MLF)

  9. Air Conditioning and Refrigeration Program Articulation, 1981-1982.

    Science.gov (United States)

    Dallas County Community Coll. District, TX.

    Based on a survey of high school programs and courses in the Dallas County Community College District (DCCCD), this articulated program is designed to prepare students for entry-level employment in the air conditioning and refrigeration industry, including residential and commercial air conditioning and commercial refrigeration. The skills and…

  10. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  11. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.

  12. Air conditioning system with supplemental ice storing and cooling capacity

    Science.gov (United States)

    Weng, Kuo-Lianq; Weng, Kuo-Liang

    1998-01-01

    The present air conditioning system with ice storing and cooling capacity can generate and store ice in its pipe assembly or in an ice storage tank particularly equipped for the system, depending on the type of the air conditioning system. The system is characterized in particular in that ice can be produced and stored in the air conditioning system whereby the time of supplying cooled air can be effectively extended with the merit that the operation cycle of the on and off of the compressor can be prolonged, extending the operation lifespan of the compressor in one aspect. In another aspect, ice production and storage in great amount can be performed in an off-peak period of the electrical power consumption and the stored ice can be utilized in the peak period of the power consumption so as to provide supplemental cooling capacity for the compressor of the air conditioning system whereby the shift of peak and off-peak power consumption can be effected with ease. The present air conditioning system can lower the installation expense for an ice-storing air conditioning system and can also be applied to an old conventional air conditioning system.

  13. Energy consumption in air-conditioning; Improvement and Reduction

    Directory of Open Access Journals (Sweden)

    Yacoub Yousef Ahmad Alotaibi

    2015-06-01

    Full Text Available Anew technique to reduce latent heat to improve energy consumption in air-conditioning is by using Desiccant . The aim of dehumidification process is to remove the water vapor from the processed air to liquid desiccants. Dehumidification is considered as a key feature of HVAC systems for thermal comfort. Chemical dehumidification is remove the water vapour from the air by transferring it towards a desiccant material (adsorption or absorption. Results illustrate that the application of liquid desiccant in air conditioning can improve indoor air quality, reduce energy consumption and bring environmentally friendly products, also. Lewis number increased rapidly with the increase of solution concentration Therefore liquid desiccant air conditioning systems are drawing more and more attention in recent years.

  14. Air Conditioning Compressor Air Leak Detection by Image Processing Techniques for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Pookongchai Kritsada

    2015-01-01

    Full Text Available This paper presents method to detect air leakage of an air conditioning compressor using image processing techniques. Quality of air conditioning compressor should not have air leakage. To test an air conditioning compressor leak, air is pumped into a compressor and then submerged into the water tank. If air bubble occurs at surface of the air conditioning compressor, that leakage compressor must be returned for maintenance. In this work a new method to detect leakage and search leakage point with high accuracy, fast, and precise processes was proposed. In a preprocessing procedure to detect the air bubbles, threshold and median filter techniques have been used. Connected component labeling technique is used to detect the air bubbles while blob analysis is searching technique to analyze group of the air bubbles in sequential images. The experiments are tested with proposed algorithm to determine the leakage point of an air conditioning compressor. The location of the leakage point was presented as coordinated point. The results demonstrated that leakage point during process could be accurately detected. The estimation point had error less than 5% compared to the real leakage point.

  15. Sea Water Air Conditioning [SWAC]: A Cost Effective Alternative

    Directory of Open Access Journals (Sweden)

    A.F. Elsafty

    2009-09-01

    Full Text Available The energy demand for air conditioning is quite extensive due to the hot and humid summer climate in Egypt. The rapid increase in non industrial electricity consumption is due to the rural electrification and the presence of many buildings that are air conditioned in summer using electricity. Deep cold ocean and sea water is a valuable natural resource that can be used for energy production, cooling, desalination, aquaculture and agriculture. The most economic viable use of this deep water is to air-condition buildings through a sea water air conditioning system (SWAC. This study reports the results of a technical and economical assessment of the potential use of sea water air conditioning (SWAC other than the conventional vapor compression systems used to air condition hotels at a new tourists resort called “Sahl-Hasheesh”,18km south of Hurghada, Egypt. This study analyzed and sized the major components of the Sea water Air Conditioning (SWAC system, determined the operational performance, and estimated the probable costs. The economic analysis was based on two different methods, the simple pay back and the net present value (NPV method. The results showed that the SWAC system is the preferred option for its short payback period as well as the minimum net present value when being applied at Sahl-Hasheesh area. Large energy savings approaching 80% compared to the conventional ones. This is in addition to the low green house gas emissions.

  16. DESIGN a solar hybrid air conditioning compressor system

    Directory of Open Access Journals (Sweden)

    Khalaji Assadi M.

    2016-01-01

    Full Text Available To develop and integrate solar hybrid system into conventional air conditioning system which provides the same cooling load with considerably less electricity demand. Solar evacuated tube and DC compressor are used for compressing the refrigerant in an air conditioning system, thus effectively reducing the air conditioning electricity consumption by up to 45%. For the flow through type selected geometry of the designed evacuated U-tube collector, a three dimensional simulation and analysis of the thermal performance was done, using the solar ray-tracing model provided by the ANSYS-FLUENT software.

  17. Simulation technology for refrigeration and air conditioning appliances

    Institute of Scientific and Technical Information of China (English)

    DING Guoliang

    2006-01-01

    Simulation technology has been widely used for performance prediction and optimal design of refrigeration and air conditioning appliances. A brief history of simulation technology for refrigeration and air conditioning appliances is reviewed. The models for evaporator, condenser, compressor, capillary tube and thermal insulation layer are summarized, and a fast calculation method for thermodynamic properties of refrigerant is introduced in this paper. The model-based intelligent simulation technology and the simulation technology based on graph theory are also illustrated. Finally, an updated trend of simulation technology development for refrigeration and air conditioning appliances is discussed.

  18. Performance and evaluation of desiccant based air conditioning system.

    Directory of Open Access Journals (Sweden)

    Gaurav S. Wani

    2014-12-01

    Full Text Available This Project work presents study and experimental analysis of Desiccant based air conditioning system.The main purpose of this project is to increase the efficency of air conditioning system.In the convenstional air conditioning system cooling coli has two load latent load and sensible load. Cooling has to cool the air and simultaneously to dehumidify it.It increases load on cooling coil and affects performance to the system. To increase the efficiency the air conditioning system desiccant materials are used at the inlet of the air conditioning test rig. Desiccant materials attract moisture based on differences in vapor pressure. Due to their enormous affinity to absorb water and considerable ability to hold water. Due to use of desiccant material load on the cooling coil reduces since moisture is absorbed by desiccant; cooling coil has to take only sensible load. Analysis is done using different desiccant materials and based on the observation, power consumption before and after desiccant is calculated. From this conclusion is made that desiccant material improves the efficiency of air conditioning test rig

  19. MARANGONI CONVECTION AROUND A VENTILATED AIR BUBBLE UNDER MICROGRAVITY CONDITIONS

    NARCIS (Netherlands)

    HOEFSLOOT, HCJ; JANSSEN, LPBM; HOOGSTRATEN, HW

    1994-01-01

    Under microgravity conditions in both parabolic and sounding rocket flights, the mass-transfer-induced Marangoni convection around an air bubble was studied. To prevent the bubble from becoming saturated, the bubble was ventilated. It turned out that the flow rate of the air through the bubble deter

  20. The microbiological quality of air improves when using air conditioning systems in cars

    OpenAIRE

    Holdack-Janssen Hinrich; Kenneweg Björn; Gastmeier Petra; Vonberg Ralf-Peter; Sohr Dorit; Chaberny Iris F

    2010-01-01

    Abstract Background Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle - and by this its impact on the risk of an allergic reaction - is yet unknown. Methods Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system...

  1. Extreme conditions in a dissolving air nanobubble.

    Science.gov (United States)

    Yasui, Kyuichi; Tuziuti, Toru; Kanematsu, Wataru

    2016-07-01

    Numerical simulations of the dissolution of an air nanobubble in water have been performed taking into account the effect of bubble dynamics (inertia of the surrounding liquid). The presence of stable bulk nanobubbles is not assumed in the present study because the bubble radius inevitably passes the nanoscale in the complete dissolution of a bubble. The bubble surface is assumed to be clean because attachment of hydrophobic materials on the bubble surface could considerably change the gas diffusion rate. The speed of the bubble collapse (the bubble wall speed) increases to about 90 m/s or less. The shape of a bubble is kept nearly spherical because the amplitude of the nonspherical component of the bubble shape is negligible compared to the instantaneous bubble radius. In other words, a bubble never disintegrates into daughter bubbles during the dissolution. At the final moment of the dissolution, the temperature inside a bubble increases to about 3000 K due to the quasiadiabatic compression. The bubble temperature is higher than 1000 K only for the final 19 ps. However, the Knudsen number is more than 0.2 for this moment, and the error associated with the continuum model should be considerable. In the final 2.3 ns, only nitrogen molecules are present inside a bubble as the solubility of nitrogen is the lowest among the gas species. The radical formation inside a bubble is negligible because the probability of nitrogen dissociation is only on the order of 10^{-15}. The pressure inside a bubble, as well as the liquid pressure at the bubble wall, increases to about 5 GPa at the final moment of dissolution. The pressure is higher than 1 GPa for the final 0.7 ns inside a bubble and for the final 0.6 ns in the liquid at the bubble wall. The liquid temperature at the bubble wall increases to about 360 K from 293 K at the final stage of the complete dissolution. PMID:27575216

  2. Measurement of Vehicle Air Conditioning Pull-Down Period

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, John F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Huff, Shean P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Moore, Larry G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); West, Brian H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-07-01

    Air conditioner usage was characterized for high heat-load summer conditions during short driving trips using a 2009 Ford Explorer and a 2009 Toyota Corolla. Vehicles were parked in the sun with windows closed to allow the cabin to become hot. Experiments were conducted by entering the instrumented vehicles in this heated condition and driving on-road with the windows up and the air conditioning set to maximum cooling, maximum fan speed and the air flow setting to recirculate cabin air rather than pull in outside humid air. The main purpose was to determine the length of time the air conditioner system would remain at or very near maximum cooling power under these severe-duty conditions. Because of the variable and somewhat uncontrolled nature of the experiments, they serve only to show that for short vehicle trips, air conditioning can remain near or at full cooling capacity for 10-minutes or significantly longer and the cabin may be uncomfortably warm during much of this time.

  3. RESOURCES MECHANISM OF REFRIGERATION AND AIR CONDITIONING TECHNOLOGY

    OpenAIRE

    Eugenio A. Ermac, Ph.D.

    2016-01-01

    This paper is an extensive analytical addendum of the research data utilized in a published research. This study determined the resources mechanism in refrigeration and air conditioning technology at CTU systems. It was conducted for the purpose of providing the administrators and its constituents the basic information on the present status of the refrigeration and air conditioning technology of the Cebu Technological University System Further, it can be inferred that insufficiency is paralle...

  4. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  5. Performance of desiccant air conditioning system with geothermal energy under different climatic conditions

    International Nuclear Information System (INIS)

    Highlights: • The performance of the hybrid air conditioning system is studied. • The influence of important operating parameters are estimated. • The ventilation, makeup and mix cycles are investigated at different climate. • The highest COP of the hybrid air conditioning system is 1.03. • The hybrid system provides a human thermal comfort at different climates. - Abstract: Energy saving still and continue a major seek in our life, due to the continuous increase in energy consumptions. So, a desiccant air conditioning system with geothermal energy is conducted in the current study. The thermal analysis of air conditioning system with its different components desiccant wheel, solar collector, heat exchanger, ground heat exchanger and water spray evaporative cooler is presented. Three different air conditioning cycles are simulated in the current study for different zones like: hot-dry zone, warm-dry zone, hot-humid zone and the warm-humid zone. The results show that the desiccant air conditioning system successfully provides a better thermal comfort condition in different climates. This hybrid system significantly decreases the supplied air temperature from 12.7 to 21.7 °C at different climate zones. When ωin,air and TReg increasing, COP decreases and the ventilation cycle provides the better COP. The highest COP value of the desiccant air conditioning system is about 1.03 while the lowest value is about 0.15. The SHR of makeup cycle is higher than that ventilation cycle at warm and hot-humid zone and vice versa at warm and hot-dry zone. The highest SHR value of the desiccant air conditioning system is about 0.99 while the lowest value is about 0.2. The Tsup,air, ωsup,air, COP and SHR isolines may easily be used for pre-evaluating of various cooling cycles in different climates. The hybrid system provides a human thermal comfort at different climates

  6. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Directory of Open Access Journals (Sweden)

    Mohamed M. El-Awad

    2011-03-01

    Full Text Available The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  7. Applicability of sewage heat pump air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    陈金华; 刘猛; 刘勇; 靳鸣; 陈洁

    2009-01-01

    A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.

  8. Monitoring and analysis of an absorption air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Perez de Vinaspre, M.; Bourouis, M.; Coronas, A. [Centro de Innovacion Tecnologica en Revalorizacion Energetica y Refrigeracion, Tarragona (Spain); Garcia, A.; Soto, V.; Pinazo, J.M. [E.T.S. Ingenieros Industriales, Valencia (Spain)

    2004-09-01

    In the last few years, high-energy consumption due to air-conditioning has led to a growing interest in the efficient use of energy in buildings. Although simulation programs have always been the main tools for analyzing energy in buildings, the reliability of their results is often compromised by a lack of certainty to reflect real conditions. The aim of this work is to monitorize and analyze the thermal behavior of an absorption-based air-conditioning installation of a university building in Tarragona, Spain. The existing monitoring system of the installation has been improved by implementing additional sensors and flow meters. The data has been stored during summer 2002 and used to assess the energy balance of the air-conditioning installation and the operational regime of the absorption chiller. [Author].

  9. Alternative air-conditioning with the use of solar energy

    International Nuclear Information System (INIS)

    The paper concerns the investigation of the alternative air condition systems on the basis of the open absorbtion cycle with the use of solar energy as a heat source. Schematic solution of systems has been carried. The design analysis of working characteristics was performed for a wide rang of initial parameters (teperature and humidity of ambient air, the type and concentration of liquid sorbents, etc.) and construction features of heat and mass transfer.(Author)

  10. Air Conditioning Systems from a 2nd Law Perspective

    OpenAIRE

    Luigi Marletta

    2010-01-01

    In this paper exergy analysis is used to assess the performance of the three most common air conditioning plant schemes: all-air, dual-duct and fan-coil systems. The results are presented in terms of flow diagrams to provide a clear picture of the exergy flow across the systems. The most relevant outcomes are that the air cooling and dehumidification is the process most responsible for the exergy loss and that the exergy efficiency of the overall systems is rather low; thus the quest for more...

  11. Intelligent Control System of Textile Mill's Air-conditioning

    Institute of Scientific and Technical Information of China (English)

    WU Fu-zhuan; ZHAO Fang

    2009-01-01

    This paper briefly analyzes the present situation of textile mill's air-conditioning system. Since it is difficult to establish detailed math model to control a textile mill's air-conditioning system because of the influence of various factors such as the differences in seasons, regions, etc., most air-conditioning equipment can not he controlled automatically. This paper suggests utilizing multi-function data acquisition card to collect the data about the temperature and humidity of a workshop, processing the data on a PC, comparing them with the expert database, and then using the 485 serial port expanding module to output the parameters, which are used to control the inverter, so that the purpose of adjusting the temperature and humidity of the workshop is achieved.

  12. Non-CFC air conditioning for transit buses

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A.A.; Parent, Y.O.; Bharathan, D.

    1992-11-01

    In the United Sates, more than 80% of transit city buses are air conditioned. Vapor compression refrigeration systems are standard for air conditioning buses and account for up to 25% of fuel consumption in the cooling season. Vapor compression devices use chlorofluorocarbons (CFCs), chemicals that contributes to Earths`s ozone depletion and to global warming. Currently, evaporative cooling is an economical alternative to CFC vapor compression refrigeration for air conditioning buses. It does not use CFCs but is restricted in use to arid climates. This limitation can be eliminated by dehumidifying the supply air using desiccants. We studied desiccant systems for cooling transit buses and found that the use of a desiccant-assisted evaporative cooling system is feasible and can deliver the required cooling. The weight and the size of the desiccant system though larger than vapor compression systems, can be easily accommodated within a bus. Fuel consumption for naming desiccant systems was about 70% less than CFC refrigeration system, resulting in payback periods of less than 2.5 years under most circumstances. This preliminary study indicated that desiccant systems combined with evaporative cooling is a CFC-free option to vapor compression refrigeration for air conditioning of transit buses. The concept is ready to be tested in a fun prototype scale in a commercial bus.

  13. Non-CFC air conditioning for transit buses

    Energy Technology Data Exchange (ETDEWEB)

    Pesaran, A.A.; Parent, Y.O.; Bharathan, D.

    1992-11-01

    In the United Sates, more than 80% of transit city buses are air conditioned. Vapor compression refrigeration systems are standard for air conditioning buses and account for up to 25% of fuel consumption in the cooling season. Vapor compression devices use chlorofluorocarbons (CFCs), chemicals that contributes to Earths's ozone depletion and to global warming. Currently, evaporative cooling is an economical alternative to CFC vapor compression refrigeration for air conditioning buses. It does not use CFCs but is restricted in use to arid climates. This limitation can be eliminated by dehumidifying the supply air using desiccants. We studied desiccant systems for cooling transit buses and found that the use of a desiccant-assisted evaporative cooling system is feasible and can deliver the required cooling. The weight and the size of the desiccant system though larger than vapor compression systems, can be easily accommodated within a bus. Fuel consumption for naming desiccant systems was about 70% less than CFC refrigeration system, resulting in payback periods of less than 2.5 years under most circumstances. This preliminary study indicated that desiccant systems combined with evaporative cooling is a CFC-free option to vapor compression refrigeration for air conditioning of transit buses. The concept is ready to be tested in a fun prototype scale in a commercial bus.

  14. Refrigerating and air conditioning systems: dilemmas in the future development

    International Nuclear Information System (INIS)

    harmful influence of CFC fluids, depletion on the ozone layer and global warming of Earth. Survey on the most applied refrigerants and their potentials for harmful influence on the ozone layer and global warming. Montreal protocol and additional regulations (amendments). Measures for a phase-out of CFCs in Republic of Macedonia, projects, forming of training centers, training courses for good maintenance and servicing of refrigerating and air conditioning systems, equipment for recovery and recycling of refrigerants. The newest alternative refrigerants and their properties. Specifics in application of the new HFC fluids. Natural refrigerants: ammonia, carbon-hydrogen's, carbon-dioxide, water, air. Failing (toxicity and flammability) and advantages in their appliance. New concepts of refrigerating and air conditioning systems. Cross way in the future development of refrigerating and air conditioning systems. Crossing of opposite views and interest on the international level. Missing of strategy in Republic of Macedonia in the field of refrigeration and air conditioning. paradox in R. Macedonia: ammonia refrigerating systems go out of use. (Author)

  15. Breakthrough for greener air-conditioning in cars

    International Nuclear Information System (INIS)

    Alter more than a decade of research and development work at SINTEF and NTNU, a patented CO2-based car air-conditioning system is now being adopted by the automotive industry. The Japanese company Denso Corporation has acquired a licence for the use of the CO2-technology in air conditioning and heat pump systems for cars. The new system offers improved energy efficiency, eliminates the emission of greenhouse gas refrigerants, and can be operated in the heat-pump mode for rapid heating in the winter season. (author)

  16. The Impact of Air Exchange Effectiveness on Thermal Comfort in an Air-Conditioned Office

    Directory of Open Access Journals (Sweden)

    Roonak Daghigh

    2009-01-01

    Full Text Available Problem statement: Impact of air exchange effectiveness on thermal comfort has not been investigated and, therefore, not well understood .Therefore, the influence of air exchange effectiveness on thermal comfort is investigated in this study. Approach: The main objective of this research is to investigate the thermal comfort level of an air-conditioned office room under 14 windows-door opening arrangements as a function of maximum, minimum and mean Air Exchange Effectiveness (AEE, as has not been inquired into already. The tracer gas decay method has been applied during the experimental procedures to estimate air exchange effectiveness, on the basis of room average and local mean age of air. Simultaneously, thermal comfort variables were measured and through these data, the thermal comforts Fanger's indices (PMV and PPD were calculated. Staff answered a survey on their sensation of the indoor climate. Results: Results of 60 survey responses to thermal comfort questions in office and indoor air quality are presented. This study has shown that there are relationship between AEE and thermal comfort and three linear regression equations of PMV versus AEE can be derived for this air-conditioned office. Conclusion: Studies on the effect of air exchange effectiveness on thermal comfort in an office have shown that Thermal comfort is influenced by AEE, which go beyond the six factors which have been taken into account in PMV modeling.

  17. Air conditioning: Low-cost autonomous air conditioning systems for bionic buildings; Klimatechnik: Bezahlbare, autarke Klimatisierung von bionischen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, H. [ARCADIS, Maastricht (Netherlands); Kutzker, A. [RUBITHERM GmbH, Hamburg (Germany)

    2005-05-01

    Termites in Africa construct buildings that are respectfully referred to as ''cathedrals'' by experts. Millions of insects inhabit these structures that are efficiently air conditioned: While the outside temperatures vary from 10 C at night to 45 C in daytime, the air inside has a constant temperature of 29 C +/- 1 C. The contribution presents a low-cost solution for human buildings. (orig.)

  18. Thermal stratification level of low sidewall air supply with air-conditioning system in large space

    Institute of Scientific and Technical Information of China (English)

    黄晨; 蔡宁; 高雪垒

    2009-01-01

    The thermal stratification level of low sidewall air supply system in large space was defined. Depending on the experiment of low sidewall air supply in summer 2008,the thermal stratification level was studied by simulation. Based on the simulation of experiment condition,the air velocity and vertical temperature distribution in a large space were simulated at different air-outlet velocities,and then the thermal stratification level line was obtained. The simulation results well match with the experimental ones and the average relative error is 3.4%. The thermal stratification level is heightened by increasing the air-outlet velocity with low sidewall air supply mode. It is concluded that when air-outlet velocity is 0.29 m/s,which is the experimental case,a uniform thermal environment in the higher occupied zone and a stable stratification level are formed. When the air-outlet velocity is low,such as 0.05 m/s,the thermal stratification level is too low and the air velocity is too small to meet the human thermal comfort in the occupied zone. So,it would be reasonable that the air-outlet velocity may be designed as 0.31 m/s if the height of the occupied zone is 2 m.

  19. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1999-01-01

    : better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; small amounts of clean air should be served gently, close to the breathing zone of each individual; individual......Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from Sick Building Syndrome (SBS) symptoms......, even though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence...

  20. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    in the built environment: better indoor air quality increases productivity and decreases SBS symptoms; unnecessary indoor pollution sources should be avoided; the air should be served cool and dry to the occupants; personalized ventilation, i.e. small amounts of clean air, should be provided gently......Air-conditioning of buildings has played a very positive role for economic development in warm climates. Still its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from SBS symptoms, even...... though existing standards and guidelines are met. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in buildings in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence...

  1. Hospital-acquired infections associated with poor air quality in air-conditioned environments

    Directory of Open Access Journals (Sweden)

    Daniela Pinheiro da Silva

    2014-04-01

    Full Text Available Backgound and Objectives: Individuals living in cities increasingly spend more time indoors in air-conditioned environments. Air conditioner contamination can be caused by the presence of aerosols from the external or internal environment, which may be associated with disease manifestations in patients present in this type of environment. Therefore, the aim of this review was to assess the air quality in air-conditioned hospital environments as a risk factor for hospital-acquired infections – HAI – as the air can be a potential source of infection, as well as assess the exposure of professionals and patients to different pollutants. Material and Methods: A literature review was performed in the LILACS, MEDLINE, SCIELO, SCIENCE DIRECT databases, CAPES thesis database and Ministry of Health – Brazil, including studies published between 1982 and 2008. The literature search was grouped according to the thematic focus, as follows: ventilation, maintenance and cleaning of systems that comprehend the environmental quality standard. Discussion and Conclusion: Outbreaks of hospital-acquired infections associated with Aspergillus, Acinetobacter, Legionella, and other genera such as Clostridium and Nocardia, which were found in air conditioners, were observed, thus indicating the need for air-conditioning quality control in these environments.

  2. Advanced Print Reading. Heating, Ventilation and Air Conditioning.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem.

    This is a workbook for students learning advanced blueprint reading for heating, ventilation, and air conditioning applications. The workbook contains eight units covering the following material: architectural working drawings; architectural symbols and dimensions; basic architectural electrical symbols; wiring symbols; basic piping symbols;…

  3. Solar air conditioning researches and demonstrations in China

    Institute of Scientific and Technical Information of China (English)

    Wang Ruzhu

    2009-01-01

    This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.

  4. Energy performance of supermarket refrigeration and air conditioning integrated systems

    OpenAIRE

    Cecchinato, Luca; Corradi, Marco; Minetto, Silvia

    2008-01-01

    Abstract The electricity consumption for air conditioning and refrigerated cases in large supermarkets represents a substantial share of the total electricity consumption. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrige...

  5. State Skill Standards: Heating, Ventilation, Air Conditioning, and Refrigeration

    Science.gov (United States)

    Ball, Larry; Soukup, Dennis

    2006-01-01

    The Department of Education has undertaken an ambitious effort to develop statewide career and technical education skill standards. The standards in this document are for Heating, Ventilation, Air Conditioning and Refrigeration (HVAC&R) programs and are designed to clearly state what the student should know and be able to do upon completion of an…

  6. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2002-01-01

    Air-conditioning of buildings has played a very positive role for economic development in warm climates. Still its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from SBS symptoms, even...

  7. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    1999-01-01

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from Sick Building Syndrome (SBS) symptoms...

  8. Human requirements in future air-conditioned environments

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2001-01-01

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from Sick Building Syndrome (SBS) symptoms...

  9. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  10. Step response and frequency response of an air conditioning system

    NARCIS (Netherlands)

    Crommelin, R.D.; Jackman, P.J.

    1978-01-01

    A system of induction units of an existing air conditioning system has been analyzed with respect to its dynamic properties. Time constants were calculated and measured by analogue models. Comparison with measurements at the installation itself showed a reasonable agreement. Frequency responses were

  11. Heating, Air-Conditioning, and Refrigeration Technician. National Skill Standards.

    Science.gov (United States)

    Vocational Technical Education Consortium of States, Decatur, GA.

    This guide contains information on the knowledge and skills identified by industry as essential to the job performance of heating, air-conditioning, and refrigeration technicians. It is intended to assist training providers in public and private institutions, as well as in industry, to develop and implement training that will provide workers with…

  12. Air Conditioning, Heating, and Refrigeration: Scope and Sequence.

    Science.gov (United States)

    Nashville - Davidson County Metropolitan Public Schools, TN.

    This scope and sequence guide, developed for an air conditioning, heating, and refrigeration vocational education program, represents an initial step in the development of a systemwide articulated curriculum sequence for all vocational programs within the Metropolitan Nashville Public School System. It was developed as a result of needs expressed…

  13. Air Conditioning, Heating, and Refrigeration. Competency-Based Curriculum Manual.

    Science.gov (United States)

    Gourley, Frank A., Jr.

    This manual was developed to serve as an aid to administrators and instructors involved with postsecondary air conditioning, heating, and refrigeration programs. The first of six chapters contains general information on program implementation, the curriculum design, facilities and equipment requirements, and textbooks and references. Chapter 2…

  14. Modelling and simulation of air-conditioning cycles

    Science.gov (United States)

    Rais, Sandi; Kadono, Yoshinori; Murayama, Katsunori; Minakuchi, Kazuya; Takeuchi, Hisae; Hasegawa, Tatsuya

    2016-05-01

    The heat-pump cycle for air conditioning was investigated both numerically and experimentally by evaluating the coefficient of performance (COP) under Japanese Industrial Standard (JIS B 8619:1999) and ANSI/AHRI standard 750-2007 operating conditions. We used two expansion valve coefficients Cv_{(\\varphi )} = 0.12 for standard operating conditions (Case 1) approaching 1.3 MPa at high pressure and 0.2 MPa at low pressure, and Cv_{(\\varphi )} = 0.06 namely poor operating conditions (Case 2). To improve the performance of the air conditioner, we compared the performance for two outside air temperatures, 35 and 40 °C (Case 3). The simulation and experiment comparison resulted the decreasing of the COP for standard operating condition is equal to 14 %, from 3.47 to 2.95 and a decrease of the cooling capacity is equal to 18 %, from 309.72 to 253.53 W. This result was also occurred in poor operating condition which the COP was superior at 35 °C temperature.

  15. Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers

    OpenAIRE

    Kalenik Marek

    2015-01-01

    Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers. The paper presents the analysis of results of the investigations concerning the influence of various constructive solutions of the air-water mixers on hydraulic operating conditions of the air lift pump. The scope of the investigations encompassed the determination of characteristics of delivery head and delivery rate for three types of air-water mixers applied in the constructed air lift p...

  16. Hollow Fiber Membrane Dehumidification Device for Air Conditioning System

    Science.gov (United States)

    Zhao, Baiwang; Peng, Na; Liang, Canzeng; Yong, Wai Fen; Chung, Tai-Shung

    2015-01-01

    In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18–22 g/m3 to a range of 13.5–18.3 g/m3. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process. PMID:26580660

  17. Hollow Fiber Membrane Dehumidification Device for Air Conditioning System.

    Science.gov (United States)

    Zhao, Baiwang; Peng, Na; Liang, Canzeng; Yong, Wai Fen; Chung, Tai-Shung

    2015-01-01

    In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18-22 g/m³ to a range of 13.5-18.3 g/m³. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process. PMID:26580660

  18. Hollow Fiber Membrane Dehumidification Device for Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Baiwang Zhao

    2015-11-01

    Full Text Available In order to provide a comfortable living and working environment indoors in tropical countries, the outdoor air often needs to be cooled and dehumidified before it enters the rooms. Membrane separation is an emerging technology for air dehumidification and it is based on the solution diffusion mechanism. Water molecules are preferentially permeating through the membranes due to its smaller kinetic diameter and higher condensability than the other gases. Compared to other dehumidification technologies such as direct cooling or desiccation, there is no phase transition involved in membrane dehumidification, neither the contact between the fresh air stream and the desiccants. Hence, membrane dehumidification would not only require less energy consumption but also avoid cross-contamination problems. A pilot scale air dehumidification system is built in this study which comprises nine pieces of one-inch PAN/PDMS hollow fiber membrane modules. A 150 h long-term test shows that the membrane modules has good water vapor transport properties by using a low vacuum force of only 0.78 bar absolute pressure at the lumen side. The water vapor concentration of the feed humid air decreases dramatically from a range of 18–22 g/m3 to a range of 13.5–18.3 g/m3. Most importantly, the total energy saving is up to 26.2% compared with the conventional air conditioning process.

  19. Efficient air conditioning. Part 2. Air quality; Effiziente Klimatisierung - Teil 2. Luftqualitaet

    Energy Technology Data Exchange (ETDEWEB)

    Haser, Herbert [Paul Wurth S.A., Luxembourg (Luxembourg)

    2002-05-01

    Like other air conditioning systems, solar air conditioners should provide 'dry cool air', i.e. hygienically acceptable air at a comfortable temperature. In the summer season and in big cities, this is not possible without air filtering and dehumidification. [German] Im Herbst vergangenen Jahres wurden in dieser Zeitschrift am Markt vorhandene Systeme fuer eine solargestuetzte Klimatisierung verglichen.In dem Artikel fordern die Verfasser 'trockene kuehle Luft fuer die Nutzer'. Diese Forderung sollte eigentlich lauten 'schadstoff- und staubarme Luft im Aufenthaltsbereiche mit Temperatur und Feuchte innerhalb des Behaglichkeitsfeldes' oder kurz gesagt: 'hygienisch einwandrei und angenehm temperiert'. Diese Forderung ist allerdings ohne eine Luftfilterung und ohne Entfeuchtung in den Innenstaedten im Sommer nicht realisierbar. (orig.)

  20. Design and Implementation of Air Conditioning System in Operating Room

    Directory of Open Access Journals (Sweden)

    Htet Htet Aung

    2014-10-01

    Full Text Available The system is air conditioning system in operating room. The main objective of the system was implemented to provide air balance and temperature necessary conditions and to control airflow system for ventilation units in operating room. The operation room can be controlled with fuzzy expert system and describes the desired outputs. Input parameters such as temperature, humidity, oxygen and particle are used and output parameters are chosen as air conditioning motor speed and exhaust motor speed. Input parameters of the system are taken into account optimal conditions based on oxygen as medium and other parameters are chosen minimum condition for operating room. The airflow control system is determined the two components: the airflow block and the thermal block for ventilation units in operating room. The mathematical modeling of each such system based on a computational procedure and to combine them together in an efficient manner. Whether it supports to the most suitable control for the system prototype was determined by simulating the operation with varying the number of personnel and duration of time. Finally, according to the combination of temperature and airflow regulations with PI controller, the results of simulation of the entire ventilation unit control system is obtained.

  1. TEWI Evaluation for Household Refrigeration and Air-Conditioning Systems

    Science.gov (United States)

    Sobue, Atsushi; Watanabe, Koichi

    In the present study, we have quantitatively evaluated the global warming impact by household refrigerator and air-conditioning systems on the basis of reliable TEWI information. In TEWI evaluation of household refrigerators, the percentage of the impact by refrigerant released to the atmosphere (direct effect) is less than 18.6% in TEWI. In case of room air-conditioners, however, the percentage of direct effect is less than 5.4% in TEWI. Therefore, it was confirmed that impact by CO2 released as a result of the energy consumed to drive the refrigeration or air-conditioning systems throughout their lifetime (indirect effect) is far larger than direct effect by the entire system. A reduction of indirect effect by energy saving is the most effective measure in reducing the global warming impact by refrigeration and air-conditioning systems, For a realization of the energy saving, not only the advanced improvement in energy efficiency by household appliance manufacturers but also the improvement of consumer's mind in selecting the systems and a way of using are concluded important.

  2. Application of Computer Model to Estimate the Consistency of Air Conditioning Systems Engineering

    OpenAIRE

    Amal El-Berry; Afrah Al-Bossly

    2013-01-01

    Reliability engineering is utilized to predict the performance and optimization of the design and maintenance of air conditioning systems. There are a number of failures associated with the conditioning systems. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely are mainly due to a variety of problems with one or more components of an air conditioner o...

  3. Hybrid liquid desiccant air-conditioning system: Experiments and simulations

    International Nuclear Information System (INIS)

    This study focuses on a hybrid liquid desiccant air-conditioning system consisting of a conventional liquid desiccant system and a vapour compression heat pump. The hybrid liquid desiccant air-conditioning system is expected to enhance the system efficiency of a conventional liquid desiccant system. In this study, the liquid desiccant is aqueous solution of lithium chloride and the refrigerant of the vapour compression heat pump is R407C. The main feature of this system is that the absorber and regenerator are integrated with the evaporator and condenser respectively. The performance evaluation test is conducted to obtain the primary data. Additionally, the improvement method for the system efficiency is discussed by the mathematical calculations. As a result, the system can dehumidify 5.9 g/kg(DA) under the conditions of summer in Tokyo, Japan. Then, the calculation results show that COPs can become higher by improving the compressor isentropic efficiency and the temperature efficiency of solution heat exchanger. - Highlights: → We focus on a hybrid liquid desiccant air-conditioning system. → The feature of the system is that the absorber is integrated with the evaporator. → We develop a mathematical model considering heat and mass transfer in the absorber. → The simulation and experiment are carried out to reveal the system performance. → COP becomes higher by improving the compressor and the solution heat exchanger.

  4. Solar air-conditioning-active, hybrid and passive

    Energy Technology Data Exchange (ETDEWEB)

    Yellott, J. I.

    1981-04-01

    After a discussion of summer air conditioning requirements in the United States, active, hybrid, and passive cooling systems are defined. Active processes and systems include absorption, Rankine cycle, and a small variety of miscellaneous systems. The hybrid solar cooling and dehumidification technology of desiccation is covered as well as evaporative cooling. The passive solar cooling processes covered include convective, radiative and evaporative cooling. Federal and state involvement in solar cooling is then discussed. (LEW)

  5. Novel Reduced GWP Refrigerant Compositions for Stationary Air Conditioning

    OpenAIRE

    Leck, Thomas J.; Naicker, Pavan K.; Hughes, Joshua; Hydutsky, Bianca

    2014-01-01

    The current fluids most widely used for small and mid-sized air conditioning systems globally are R-410A and R-22. While these fluids have many positive attributes for cooling, they are the subject of valid criticisms regarding their high direct global warming potential (GWP) and, in the case of R-22, ozone depletion potential (ODP) also. In the interest of improved environmental sustainability, a new class of refrigerant molecule has been developed, the hydrofluoroolefin, or HFO. While the v...

  6. Analysis on a hybrid desiccant air-conditioning system

    International Nuclear Information System (INIS)

    Hybrid desiccant-assisted preconditioner and split cooling coil system, which combines the merits of moisture removal by desiccant and cooling coil for sensible heat removal, is a potential alternative to conventional vapor compression cooling systems. In this paper, experiments on a hybrid desiccant air-conditioning system, which is actually an integration of a rotary solid desiccant dehumidification and a vapor compression air-conditioning unit, had been carried out. It is found that, compared with the conventional VC (vapor compression) system, the hybrid desiccant cooling system economizes 37.5% electricity powers when the process air temperature and relative humidity are maintained at 30 oC, and 55% respectively. The reason why the hybrid desiccant cooling system features better performance relative to the VC system lies in the improvement brought about in the performance of the evaporator in VC unit due to desiccant dehumidification. A thermodynamic model of the hybrid desiccant system with R-22 as the refrigerant has been developed and the impact of operating parameters on the sensible heat ratio of the evaporator and the electric power saving rate has been analyzed. It is found that a majority of evaporators can operate in the dry condition even if the regeneration temperature is lower (i.e. 80 oC)

  7. An energy impact assessment of indoor air quality acceptance for air-conditioned offices

    International Nuclear Information System (INIS)

    Treatment of fresh air in ventilation systems for the air-conditioning consumes a considerable amount of energy and affects the indoor air quality (IAQ). The ventilation demand is primarily related to the occupant load. In this study, the ventilation demands due to occupant load variations and occupant acceptability were examined against certain IAQ objectives using the mass balance of carbon dioxide (CO2) concentrations in an air-conditioned office. In particular, this study proposed a ventilation model for the consideration of the occupant load variations and occupant acceptability based on the regional survey of typical offices (422 samples) in Hong Kong. The model was applied to evaluate the relative energy performance of different IAQ objectives in ventilation systems for typical office buildings in Hong Kong. The results showed that the energy consumption of a ventilation system would be correlated with the occupant load and acceptability in the air-conditioned office. Indicative CO2 levels of 800 ppmv, 1000 ppmv and 1200 ppmv corresponding to 83%, 97% and 99.7% survey samples were shown, corresponding to the thermal energy consumptions of 1500 MJ m-2 yr-1, 960 MJ m-2 yr-1and 670 MJ m-2 yr-1, respectively. In regards to the monetary issue, an annual value of HK$ 762 million per year in electrical consumption could be saved in all office buildings in Hong Kong when the indoor target CO2 concentration is increased from 1000 ppmv to 1200 ppmv. To achieve an excellent IAQ following the existing design standard, i.e. to decrease the CO2 level from 1000 ppmv to 800 ppmv, 56% additional energy would be consumed, corresponding to an annual value of HK$ 1,419 million, even though the occupant acceptability is only improved from 81% to 86%. The development of the models in this study would be useful for the energy performance evaluation of ventilation systems in air-conditioned offices

  8. Report of study 7.3: cooling and air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.

    2000-07-01

    This report describes the results of the study carried out by the study group 7.3 in the triennium 1997-2000. The study was focused on industrial refrigeration and air conditioning for the large building utilising natural gas. The goal of this study, carried out in collaboration of the members of study group 7.3, was to analyse the markets of industrial refrigeration and air conditioning for large buildings to identify possibilities to increase the natural gas share in these sectors. The available technology in the two sectors of the market are described in a single section, i.e. the 'State of the art of the technology'. In this section, technical characteristics, applications, performances, new developments and others topics are discussed for absorbers, gas engines, gas turbines and fuel cells. In the 'Industrial Refrigeration' section an analysis of the present global market for the industrial sector is presented. Economics, advantages and barriers to gas units compared with the electrical units are discussed. Information on existing industrial plants, possible application options and new technology developments are described as well. The 'Air conditioning for the large building' section deals with offices, hotels, commercial buildings, hospitals and shopping centres with a cooling capacity of 350 kW or higher. It appears that the use of natural gas for cooling of large buildings has been increasing during the last decade, thanks to the greater availability of natural gas and the development of new technologies. A marketing survey of gas air-conditioning was carried out in cooperation with a group of Intergas Marketing. Based on the survey, the report describes the market position of natural gas relative to electricity. It provides the strategic prospects for further developing natural gas as a competitive option for air-conditioning of large buildings using a combination of state-of-the-art technologies. It is important to highlight

  9. Response of continuous air monitors in simulated conditions

    International Nuclear Information System (INIS)

    Continuous air monitors (CAM) are widely used in nuclear industry for checking airborne activity in radioactive areas. Mathematical equations related to response of CAM's in assessing airborne activities are derived and presented in this paper. A case study is carried out for a model with necessary inputs. Assumed model is similar to areas in nuclear power plants. Graphical simulation results are used to analyze the conditions and its radiological significance. The response predictions can also be used to calculate alarm set points that correspond to appropriate limits on the concentration of airborne radioactivity in the sampled air. Equations can be modified further to find the response for different scenarios. Using these we can predict the escape rate of activity from the system even in minute levels. (author)

  10. Particulate composition characteristics under different ambient air quality conditions.

    Science.gov (United States)

    Tsai, Jiun-Horng; Chang, Lisa Tzu-Chi; Huang, Yao-Sheng; Chiang, Hung-Lung

    2011-07-01

    Particulate compositions including elemental carbon (EC), organic carbon (OC), water-soluble ionic species, and elemental compositions were investigated during the period from 2004 to 2006 in southern Taiwan. The correlation between the pollutant standard index (PSI) of ambient air quality and the various particle compositions was also addressed in this study. PSI revealed a correlation with fine (r = 0.74) and coarse (r = 0.80) particulate matter (PM). PSI manifested a significant correlation with the amount of analyzed ionic species (r approximately 0.80) in coarse and fine particles and a moderate correlation with carbon content (r = 0.63) in fine particles; however, it showed no correlation with elemental content. Although the ambient air quality ranged from good to moderate, the ionic species including chloride (Cl-), nitrate (NO3-), sulfate (SO4(2-)), sodium (Na+), ammonium (NH4+), magnesium (Mg2+), and calcium (Ca2+) increased significantly (1.5-3.7 times for Daliao and 1.8-6.9 times for Tzouying) in coarse PM. For fine particles, NO3-, SO4(2-), NH4+, and potassium (K+) also increased significantly (1.3-2.4 times for Daliao and 2.8-9.6 times for Tzouying) when the air quality went from good to moderate. For meteorological parameters, temperature evidenced a slightly negative correlation with PM concentration and PSI value, which implied a high PM concentration in the low-temperature condition. This reflects the high frequency of PM episodes in winter and spring in southern Taiwan. In addition, the mixing height increase from 980 to 1450 m corresponds to the air quality condition changing from unhealthy to good. PMID:21850835

  11. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air-conditioning....... Binary Ice as secondary refrigerant for air-conditioning purposes is an economical and technically feasible solution in any climate. Whatever chilled water can do in an air-conditioning installation ? Binary Ice can do it better....

  12. Risk assessment for radon in an air-conditioned workplace

    International Nuclear Information System (INIS)

    The International Commission on Radiological Protection (ICRP) has proposed a conversion of 5mSv/WLM for risk assessment from workplace exposure to radon progeny. Currently the new ICRP Respiratory Tract Model leads to dose conversion factors (DCF) that are higher by at least a factor of 2.5 and the ICRP Model has not been recommended for assessment of risk for inhalation of radon progeny. However the model can he used to investigate the dependency of the DCF values on the atmospheric conditions. This paper describes measurements made using wire screen diffusion batteries of the radon progeny activity size distributions in the air-conditioned basement of a scientific laboratory. The results show that during work hours with the air-conditioning operating the average radon equilibrium factor was 0.11 while the average unattached fraction was ∼28%. The average radon progeny-based DCF values were found to be more than a factor of two greater than the conversion convention. Also it was found that a DCF value derived in terms of radon exposure (Bq m-3 h) had a range of a factor of 6 over the two week period of the measurements, suggesting that radon levels are not an adequate indicator of inhalation risk in these circumstances. 10 refs., 1 tab., 4 figs

  13. Proposal for energy saving in air conditioning equipment; Propuesta para ahorro energetico en acondicionadores de aire

    Energy Technology Data Exchange (ETDEWEB)

    Solis Recendez, Daniel H [Division de Ingenieria Electrica, Universidad Nacional Autonoma de Mexico (Mexico)

    2008-10-15

    In the last decades, the air conditioning systems have become a crucial part in the search from comfort in extreme climates. Nevertheless, they have also become one of the greatest energy consumers. In this article it is proposed that the final conditions that the air conditioning equipment looks for not to be fixed, but variable in respect to a certain comfort zone. This zone is a variation of the used one in the bio-climatic chart of Olgyay that considers the rapidity whereupon the reached conditions tend to leave the comfort zone. It is analyzed how to choose the point on the zone that costs less energy in arriving to it. [Spanish] En las ultimas decadas, los sistemas de aire acondicionado se han vuelto una parte crucial en la busqueda de confort en climas extremosos. Sin embargo, tambien se han vuelto de los mayores consumidores de energia. En este articulo se propone que las condiciones finales que busquen lograr los acondicionadores no sean fijas, si no variables respecto a una determinada zona de confort. Dicha zona es una variacion de la utilizada en la carta bioclimatica de Olgyay, que considera la rapidez con que las condiciones alcanzadas tienden a abandonar la zona de confort. Se discute como elegir el punto sobre la zona que cueste menos energia en llegara el.

  14. Engine-driven hybrid air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    Chaokui QIN; Hongmei LU; Xiong LIU; Gerhard SCHMITZ

    2009-01-01

    A hybrid air-conditioning system that com-bines an engine-driven chiller with desiccant dehumidifi-cation was configured and experimentally tested to provide reliable data for energy consumption and operation cost. The engine performance and the desiccant wheel perfor-mance were measured and a numeric model previously set up for dehumidification capacity prediction was validated. For a reference building, the results based upon measured data show that under present electricity/gas price ratio, more than 40% of operation cost can be saved by the hybrid system.

  15. Do-It-Yourself Additives Recharge Auto Air Conditioning

    Science.gov (United States)

    2010-01-01

    In planning for a return mission to the Moon, NASA aimed to improve the thermal control systems that keep astronauts comfortable and cool while inside a spacecraft. Goddard Space Flight Center awarded a Small Business Innovation Research (SBIR) contract to Mainstream Engineering Corporation, of Rockledge, Florida, to develop a chemical/mechanical heat pump. IDQ Inc., of Garland, Texas, exclusively licensed the technology and incorporates it into its line of Arctic Freeze products for automotive air conditioning applications. While working on the design, Mainstream Engineering came up with a unique liquid additive called QwikBoost to enhance the performance of the advanced heat pump design.

  16. Investigation of air cleaning system response to accident conditions

    International Nuclear Information System (INIS)

    Air cleaning system response to the stress of accident conditions are being investigated. A program overview and hghlight recent results of our investigation are presented. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. The test facilities used to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components are described. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported

  17. Investigation of air cleaning system response to accident conditions

    International Nuclear Information System (INIS)

    We are investigating air cleaning system response to the stress of accident conditions. In this paper we present a program overview and highlight recent results of our investigations. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. We also describe the test facilities we use to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported

  18. Control of Computer Room Air Conditioning using IT Equipment Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Bell, Geoffrey C.; Storey, Bill; Patterson, Michael K.

    2009-09-30

    The goal of this demonstration was to show how sensors in IT equipment could be accessed and used to directly control computer room air conditioning. The data provided from the sensors is available on the IT network and the challenge for this project was to connect this information to the computer room air handler's control system. A control strategy was developed to enable separate control of the chilled water flow and the fans in the computer room air handlers. By using these existing sensors in the IT equipment, an additional control system is eliminated (or could be redundant) and optimal cooling can be provided saving significant energy. Using onboard server temperature sensors will yield significant energy reductions in data centers. Intel hosted the demonstration in its Santa Clara, CA data center. Intel collaborated with IBM, HP, Emerson, Wunderlich-Malec Engineers, FieldServer Technologies, and LBNL to install the necessary components and develop the new control scheme. LBNL also validated the results of the demonstration.

  19. On the impact of entrapped air in infiltration under ponding conditions. Part a: Preferential air flow path effects on infiltration

    Science.gov (United States)

    Mizrahi, Guy; Weisbrod, Noam; Furman, Alex

    2015-04-01

    Entrapped air effects on infiltration under ponding conditions could be important for massive infiltration of managed aquifer recharge (MAR) or soil aquifer treatment (SAT) of treated wastewater. Earlier studies found that under ponding conditions, air is being entrapped and compressed until it reaches a pressure which will enable the air to escape (unstable air flow). They also found that entrapped air could reduce infiltration by 70-90%. Most studies have dealt with entrapped air effects when soil surface topography is flat. The objective of this study is to investigate, under ponding conditions, the effects of: (1) irregular surface topography on preferential air flow path development (stable air flow); (2) preferential air flow path on infiltration; and (3) hydraulic head on infiltration when air is trapped. Column experiments were used to investigate these particular effects. A 140 cm deep and 30 cm wide column packed with silica sand was used under two boundary conditions: in the first, air can only escape vertically upward through the soil surface; in the second, air is free to escape through 20 ports installed along the column perimeter. The surface was flooded with 13 liters of water, with ponding depth decreasing with time. Two soil surface conditions were tested: flat surface and irregular surface (high and low surface zones). Additionally, Helle-show experiments were conducted in order to obtain a visual observation of preferential air flow path development. The measurements were carried out using a tension meter, air pressure transducers, TDR and video cameras. It was found that in irregular surfaces, stable air flow through preferential paths was developed in the high altitude zones. Flat surface topography caused unstable air flow through random paths. Comparison between irregular and flat surface topography showed that the entrapped air pressure was lower and the infiltration rate was about 40% higher in the irregular surface topography than in the

  20. 40 CFR 86.161-00 - Air conditioning environmental test facility ambient requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Air conditioning environmental test... conditioning environmental test facility ambient requirements. The goal of an air conditioning test facility is..., within the test cell, during all phases of the air conditioning test sequence to 95 ±2 °F on average...

  1. Performance enhancement of a subcooled cold storage air conditioning system

    International Nuclear Information System (INIS)

    This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.

  2. Voltage controller design for air conditioning; Diseno de controlador de voltaje para aire acondicionado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Andrade, R; Lopez Villalobos, J.J; Valderrama Chairez, J; Ramirez, R.L. [Instituto Tecnologico de Nuevo Leon, Guadalupe, Nuevo Leon (Mexico)]. E-mails: roxana_garciaandrade@yahoo.com; xe2n@yahoo.com.mx; jose.valderrama@ieee.org

    2013-03-15

    This paper discusses the design of a voltage controller for an air conditioning system in order to generate additional power in activation or startup of the system, for which as a first stage is presented the modeling power generation of electric current through alternative means, such as solar energy. The results of this study will be the basis for development of the physical prototype of this system controller. [Spanish] El presente trabajo trata sobre el diseno de un controlador de voltaje para un sistema de aire acondicionado con el fin de generar energia adicional en la activacion o arranque de dicho sistema, para lo cual como primer fase se presenta el modelado de la generacion de corriente electrica mediante medios alternos, como lo es la energia solar. Los resultados de este trabajo seran la base para desarrollo del prototipo fisico de este sistema controlador.

  3. Energy performance of supermarket refrigeration and air conditioning integrated systems

    International Nuclear Information System (INIS)

    The electricity consumption for air conditioning and refrigerated cases in large supermarkets represents a substantial share of the total electricity consumption. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low-temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study is aimed at investigating the performance of different lay-out and technological solutions and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis chillers and heat pumps working with R410A, medium temperature systems working with R404A and low-temperature systems working both with R404A and R744 were considered. The investigated solutions enable an annual energy saving higher than 15% with respect to the baseline solution for the considered climates.

  4. Experimental Research on Liquid Desiccant Air-conditioning Unit

    Directory of Open Access Journals (Sweden)

    Feng Yueyan

    2016-01-01

    Full Text Available An experimental device of liquid desiccant air conditioning system is established. Experimental tests about the temperature difference between diluted solution of inlet and concentrated solution of exit in the solution heat exchanger are carried on, and CaCl2 solution is used as desiccant. Results show that: the fluctuation range in the day at different times of the basic difference of the measured temperature does not exceed 1°C, and the temperature difference between diluted solution of inlet and concentrated solution of exit in solution heat exchanger appears the minimum value of 2.7°C and the maximum value of 10.2°C. Also, the percent of the additional load and the ratio of additional load to the evaporator load are analyzed.

  5. 8th International Symposium on Heating, Ventilation and Air Conditioning

    CERN Document Server

    Zhu, Yingxin; Li, Yuguo; Vol.1 Indoor and Outdoor Environment; Vol.2 HVAC&R Component and Energy System; Vol.3 Building Simulation and Information Management

    2014-01-01

    Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning is based on the 8th International Symposium of the same name (ISHVAC2013), which took place in Xi’an on October 19-21, 2013. The conference series was initiated at Tsinghua University in 1991 and has since become the premier international HVAC conference initiated in China, playing a significant part in the development of HVAC and indoor environmental research and industry around the world. This international conference provided an exclusive opportunity for policy-makers, designers, researchers, engineers and managers to share their experience. Considering the recent attention on building energy consumption and indoor environments, ISHVAC2013 provided a global platform for discussing recent research on and developments in different aspects of HVAC systems and components, with a focus on building energy consumption, energy efficiency and indoor environments. These categories span a broad range of topics, and the proce...

  6. Prediction of Air Conditioning Load Response for Providing Spinning Reserve - ORNL Report

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Ally, Moonis Raza [ORNL; Rice, C Keith [ORNL

    2009-02-01

    This report assesses the use of air conditioning load for providing spinning reserve and discusses the barriers and opportunities. Air conditioning load is well suited for this service because it often increases during heavy load periods and can be curtailed for short periods with little impact to the customer. The report also provides an appendix describing the ambient temperature effect on air conditioning load.

  7. 40 CFR 86.1832-01 - Optional equipment and air conditioning for test vehicles.

    Science.gov (United States)

    2010-07-01

    ... Optional equipment and air conditioning for test vehicles. For test vehicles selected under §§ 86.1822-01... be expected to influence emissions include, but are not limited to: air conditioning, power steering...) Except for air conditioning, where it is expected that 33 percent or less of a car line, within a...

  8. 77 FR 33315 - Protection of Stratospheric Ozone: Alternative for the Motor Vehicle Air Conditioning Sector...

    Science.gov (United States)

    2012-06-06

    ... Air Conditioning Sector Under the Significant New Alternatives Policy (SNAP) Program AGENCY...) within the refrigeration and air-conditioning sector. This final rule only concerns the use of CO 2 in... their suppliers with a refrigerant option subject to use conditions for motor vehicle air...

  9. 40 CFR 86.162-03 - Approval of alternative air conditioning test simulations.

    Science.gov (United States)

    2010-07-01

    ... alternative air conditioning test simulations. (a) Upon petition from a manufacturer or upon the Agency's own initiative, the Administrator will approve a simulation of the environmental cell for air conditioning test... the tailpipe emissions, air conditioning compressor load, and fuel economy. (2) For any...

  10. 40 CFR 86.166-12 - Method for calculating emissions due to air conditioning leakage.

    Science.gov (United States)

    2010-07-01

    ... to air conditioning leakage. 86.166-12 Section 86.166-12 Protection of Environment ENVIRONMENTAL... for calculating emissions due to air conditioning leakage. This section describes procedures used to determine a refrigerant leakage rate in grams per year from vehicle-based air conditioning units....

  11. 40 CFR 86.165-12 - Air conditioning idle test procedure.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Air conditioning idle test procedure... Complete Heavy-Duty Vehicles; Test Procedures § 86.165-12 Air conditioning idle test procedure. (a) Applicability. This section describes procedures for determining air conditioning-related CO2 emissions...

  12. 76 FR 17487 - Protection of Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector...

    Science.gov (United States)

    2011-03-29

    ...: New Substitute in the Motor Vehicle Air Conditioning Sector Under the Significant New Alternatives... Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector Under the Significant New... expanding the list of acceptable substitutes for use in the motor vehicle air conditioning end-use as...

  13. CFD SIMULATION OF AIR ION REGIME IN WORK AREAS AT CONDITION OF ARTIFICIAL AIR IONIZATION

    Directory of Open Access Journals (Sweden)

    M. M. Biliaiev

    2016-04-01

    sources and ions of different polarity; physical processes affecting the formation of ions concentration field. Practical value. The obtained 2D CFD model for calculating the air ions regime in working areas allow to calculate the concentration of ions at the location of the respiratory organs, taking into account the basic physical factors determining the formation of ions concentration fields. It will allow rationally arranged the ionizers in the working premises to create the comfortable working conditions for staff.

  14. Understanding the Dehumidification Performance of Air-Conditioning Equipment at Part-Load Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Don B. Shirey III; Hugh I. Henderson Jr; Richard A. Raustad

    2006-01-01

    Air conditioner cooling coils typically provide both sensible cooling and moisture removal. Data from a limited number of field studies (Khattar et al. 1985; Henderson and Rengarajan 1996; Henderson 1998) have demonstrated that the moisture removal capacity of a cooling coil degrades at part-load conditions--especially when the supply fan operates continuously while the cooling coil cycles on and off. Degradation occurs because moisture that condenses on the coil surfaces during the cooling cycle evaporates back into air stream when the coil is off. This degradation affects the ability of cooling equipment to maintain proper indoor humidity levels and may negatively impact indoor air quality. This report summarizes the results of a comprehensive project to better understand and quantify the moisture removal (dehumidification) performance of cooling coils at part-load conditions. A review of the open literature was initially conducted to learn from previous research on this topic. Detailed performance measurements were then collected for eight cooling coils in a controlled laboratory setting to understand the impact of coil geometry and operating conditions on transient moisture condensation and evaporation by the coils. Measurements of cooling coil dehumidification performance and space humidity levels were also collected at seven field test sites. Finally, an existing engineering model to predict dehumidification performance degradation for single-stage cooling equipment at part-load conditions (Henderson and Rengarajan 1996) was enhanced to include a broader range of fan control strategies and an improved theoretical basis for modeling off-cycle moisture evaporation from cooling coils. The improved model was validated with the laboratory measurements, and this report provides guidance for users regarding proper model inputs. The model is suitable for use in computerized calculation procedures such as hourly or sub-hourly building energy simulation programs (e

  15. Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers

    Directory of Open Access Journals (Sweden)

    Kalenik Marek

    2015-03-01

    Full Text Available Investigations of hydraulic operating conditions of air lift pump with three types of air-water mixers. The paper presents the analysis of results of the investigations concerning the influence of various constructive solutions of the air-water mixers on hydraulic operating conditions of the air lift pump. The scope of the investigations encompassed the determination of characteristics of delivery head and delivery rate for three types of air-water mixers applied in the constructed air lift pump. Using the obtained results, the efficiency of the three types of air-water mixers applied in this air lift pump was determined. The analysis was carried out and there was checked whether the improved analytical Stenning-Martin model can be used to design air lift pumps with the air-water mixers of these types. The highest capacity in the water transport was reached by the air lift pump with the 1st type air-water mixer, the lowest one – with the 3rd type air-water mixer. The water flow in the air lift pump increases along with the rise in the air flow. The lower are the hydraulic losses generated during flow of the air flux by the air-water mixer, the higher is the air lift pump capacity. Along with the rise in the water delivery head, the capacity of the air lift pump decreases. The highest efficiency is reached by the air lift pump with the 1st type air-water mixer, the lowest – with the 3st type air-water mixer. The efficiency of the air lift pump for the three investigated types of air-water mixers decreases along with the rise in air flow rate and water delivery head. The values of submergence ratio (h/L of the delivery pipe, calculated with the use of the improved analytical Stenning-Martin model, coincide quite well with the values of h/L determined from the measurements.

  16. On the impact of entrapped air in infiltration under ponding conditions: Part a: Preferential air flow path effects on infiltration

    Science.gov (United States)

    Weisbord, N.; Mizrahi, G.; Furman, A.

    2015-12-01

    Entrapped air effects on infiltration under ponding conditions could be important for massive infiltration of managed aquifer recharge or soil aquifer treatment. Earlier studies found that under ponding conditions air could reduce infiltration by 70-90%. Most studies have dealt with entrapped air effects when soil surface topography is flat. The objective of this study is to investigate the effects of: (1) irregular surface topography on preferential air flow path development; (2) preferential air flow path on infiltration; and (3) hydraulic head on infiltration when air is trapped. Column experiments were used to investigate these particular effects. A 140 cm deep and 30 cm wide column packed with silica sand was used under two boundary conditions: in the first, air can only escape vertically upward through the soil surface; in the second, air is free to escape. The surface was flooded with 13 liters of water, with ponding depth decreasing with time. Two soil surface conditions were tested: flat surface and irregular. It was found that in irregular surfaces, stable air flow through preferential paths was developed in the high altitude zones. Flat surface topography caused unstable air flow through random paths. Comparison between irregular and flat surface topography showed that the entrapped air pressure was lower and the infiltration rate was about 40% higher in the irregular surface topography than in the flat surface topography. No difference of infiltration rate between flat and irregular surface topography was observed when air was free to escape along the infiltration path. It was also found that at the first stage of infiltration, higher hydraulic heads caused higher entrapped air pressures and lower infiltration rates. In contrast, higher hydraulic head results in higher infiltration rate, when air was free to escape. Our results suggest that during ponding conditions: (1) preferential air flow paths develop at high surface zones of irregular topography

  17. Indoor Air quality related to occupancy at an air-conditioned public building

    Directory of Open Access Journals (Sweden)

    Karina Ponsoni

    2010-02-01

    Full Text Available To characterize the influence of occupancy on the indoor air quality, a public office building with air-conditioning system was selected for this study. The indoor parameters included total bacteria count, total fungal count, temperature, relative humidity, and carbon dioxide concentration. The number of occupants, which varied throughout the day, was recorded in each sample. The samples were taken before the beginning of the working day and during 3 h, at an interval of 30 min between each sampling, and continued for five working days during a week. Correlation analysis demonstrated that occupancy rates were positively correlated with airborne bacteria, CO2, and temperature. No significant association between the number of occupants and fungus was observed. The results of this study provided information on the variability of indoor air parameters during the time-varying occupancy over the course of the day in at air-conditioned buildings where occupancy was quite dynamic.Com o objetivo de caracterizar a influência da ocupação na qualidade do ar interior, um edifício público com sistema de ar condicionado foi selecionado. As variáveis ambientais consideradas incluíram contagem total de bactérias e fungos, temperatura, umidade relativa e concentração de dióxido de carbono. O número de ocupantes, que variou durante todo o dia, foi estimado em cada amostragem. As amostras foram coletadas antes do início do expediente de trabalho e durante 3 horas, em intervalos de 30 minutos, por 5 dias úteis consecutivos. A análise de correlação demonstrou que a taxa de ocupação foi correlacionada positivamente com a concentração de bactérias, dióxido de carbono e temperatura. Nenhuma associação significativa foi observada entre o número de ocupantes e concentração de fungos. Os resultados deste estudo fornecem informações quanto à variabilidade nos parâmetros do ar interior no decorrer do dia em um edifício onde a ocupação

  18. Does urban vegetation mitigate air pollution in northern conditions?

    International Nuclear Information System (INIS)

    It is generally accepted that urban vegetation improves air quality and thereby enhances the well-being of citizens. However, empirical evidence on the potential of urban trees to mitigate air pollution is meager, particularly in northern climates with a short growing season. We studied the ability of urban park/forest vegetation to remove air pollutants (NO2, anthropogenic VOCs and particle deposition) using passive samplers in two Finnish cities. Concentrations of each pollutant in August (summer; leaf-period) and March (winter, leaf-free period) were slightly but often insignificantly lower under tree canopies than in adjacent open areas, suggesting that the role of foliage in removing air pollutants is insignificant. Furthermore, vegetation-related environmental variables (canopy closure, number and size of trees, density of understorey vegetation) did not explain the variation in pollution concentrations. Our results suggest that the ability of urban vegetation to remove air pollutants is minor in northern climates. -- Highlights: ► The ability of northern urban vegetation to remove air pollutants is minor. ► Vegetation-related environmental variables had no effect on air pollution levels. ► The ability of vegetation to clean air did not differ between summer and winter. ► Dry deposition passive samplers proved applicable in urban air pollution study. -- The ability of urban vegetation to remove air pollutants seems to be minor in northern climates

  19. Central air conditioning based on adsorption and solar energy

    International Nuclear Information System (INIS)

    This paper presents the characterization and the pre-dimensioning of an adsorption chiller as part of a 20 kW air conditioning central unit for cooling a set of rooms that comprises an area of 110 m2. The system is basically made up of a cold water storage tank supplied by an activated carbon-methanol adsorption chiller, a hot water storage tank, fed by solar energy and natural gas, and a fan-coil. During an acclimatization of 8 h (9-17 h), the following parameters were obtained for dimensioning the cooling system: 504 kg of activated carbon, 180 L of methanol, 7000 L of hot water, 10,300 L of cold water with its temperature varying in the fan-coil from 1 deg. C to 14 C. Considering the mean value of the total daily irradiation in Joao Pessoa (7o8'S, 34o50'WG), and a cover of regenerating heat supplied by solar energy equivalent to 70%, the adsorption chiller's expected coefficient of performance (COP) was found to be around 0.6.

  20. Thermoeconomic evaluation of air conditioning system with chilled water storage

    International Nuclear Information System (INIS)

    Highlights: • A new thermoeconomic evaluation methodology has been presented. • The relationship between thermodynamic and economic performances has been revealed. • A key point for thermal storage technology further application is discovered. • A system has been analyzed via the new method and EUD method. - Abstract: As a good load shifting technology for power grid, chilled energy storage has been paid more and more attention, but it always consumes more energy than traditional air conditioning system, and the performance analysis is mostly from the viewpoint of peak-valley power price to get cost saving. The paper presents a thermoeconomic evaluation methodology for the system with chilled energy storage, by which thermodynamic performance influence on cost saving has been revealed. And a system with chilled storage has been analyzed, which can save more than 15% of power cost with no energy consumption increment, and just certain difference between peak and valley power prices can make the technology for good economic application. The results show that difference between peak and valley power prices is not the only factor on economic performance, thermodynamic performance of the storage system is the more important factor, and too big price difference is a barrier for its application, instead of for more cost saving. All of these give a new direction for thermal storage technology application

  1. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    H. Mirinejad

    2008-01-01

    Full Text Available Problem statement: Heating, Ventilating and Air Conditioning (HVAC systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort field is introduced, followed by a review and comparison of the main existing control techniques used in HVAC systems to date. Results: The present overview shows that intelligent controllers which are based on the human sensation of thermal comfort have a better performance in providing thermal comfort as well as energy saving than the traditional controllers and those based on a model of the HVAC system. Conclusion: Such an overview provides an insight into current control methods in HVAC systems and can help scholars and HVAC learners to have the comprehensive information about a variety of control techniques in the field of HVAC and therefore to better design a proper controller for their work

  2. Assessing summertime urban air conditioning consumption in a semiarid environment

    Science.gov (United States)

    Salamanca, F.; Georgescu, M.; Mahalov, A.; Moustaoui, M.; Wang, M.; Svoma, B. M.

    2013-09-01

    Evaluation of built environment energy demand is necessary in light of global projections of urban expansion. Of particular concern are rapidly expanding urban areas in environments where consumption requirements for cooling are excessive. Here, we simulate urban air conditioning (AC) electric consumption for several extreme heat events during summertime over a semiarid metropolitan area with the Weather Research and Forecasting (WRF) model coupled to a multilayer building energy scheme. Observed total load values obtained from an electric utility company were split into two parts, one linked to meteorology (i.e., AC consumption) which was compared to WRF simulations, and another to human behavior. WRF-simulated non-dimensional AC consumption profiles compared favorably to diurnal observations in terms of both amplitude and timing. The hourly ratio of AC to total electricity consumption accounted for ˜53% of diurnally averaged total electric demand, ranging from ˜35% during early morning to ˜65% during evening hours. Our work highlights the importance of modeling AC electricity consumption and its role for the sustainable planning of future urban energy needs. Finally, the methodology presented in this article establishes a new energy consumption-modeling framework that can be applied to any urban environment where the use of AC systems is prevalent.

  3. Assessing summertime urban air conditioning consumption in a semiarid environment

    International Nuclear Information System (INIS)

    Evaluation of built environment energy demand is necessary in light of global projections of urban expansion. Of particular concern are rapidly expanding urban areas in environments where consumption requirements for cooling are excessive. Here, we simulate urban air conditioning (AC) electric consumption for several extreme heat events during summertime over a semiarid metropolitan area with the Weather Research and Forecasting (WRF) model coupled to a multilayer building energy scheme. Observed total load values obtained from an electric utility company were split into two parts, one linked to meteorology (i.e., AC consumption) which was compared to WRF simulations, and another to human behavior. WRF-simulated non-dimensional AC consumption profiles compared favorably to diurnal observations in terms of both amplitude and timing. The hourly ratio of AC to total electricity consumption accounted for ∼53% of diurnally averaged total electric demand, ranging from ∼35% during early morning to ∼65% during evening hours. Our work highlights the importance of modeling AC electricity consumption and its role for the sustainable planning of future urban energy needs. Finally, the methodology presented in this article establishes a new energy consumption-modeling framework that can be applied to any urban environment where the use of AC systems is prevalent. (letter)

  4. The system of thermoelectric air conditioning based on permeable thermoelements

    OpenAIRE

    Cherkez R. G.

    2009-01-01

    There is thermoelectric air conditioner unit on the basis of permeable cooling thermoelements presented. In thermoelectric air conditioner unit the thermoelectric effects and the Joule–Thomson effect have been used for the air stream cooling. There have been described the method of temperature distribution analysis, the determinations of energy conversion power characteristics and design style of permeable thermoelement with maximum coefficient of performance described. The results of compute...

  5. Application of Computer Model to Estimate the Consistency of Air Conditioning Systems Engineering

    Directory of Open Access Journals (Sweden)

    Amal El-Berry

    2013-04-01

    Full Text Available Reliability engineering is utilized to predict the performance and optimization of the design and maintenance of air conditioning systems. There are a number of failures associated with the conditioning systems. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely are mainly due to a variety of problems with one or more components of an air conditioner or air conditioning system. To maintain the system forecasting for system failure rates are very important. The focus of this paper is the reliability of the air conditioning systems. The most common applied statistical distributions in reliability settings are the standard (2 parameter Weibull and Gamma distributions. Reliability estimations and predictions are used to evaluate, when the estimation of distributionsparameters is done. To estimate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several companies’ departments is checked. This air conditioning system is divided into two systems, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40 - 45oF (4 - 7oC. The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, with the application of the Weibull and Gamma distributions it is indicated that the reliability for the systems equal to 86.012% and 77.7% respectively . A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families is studied. It is found that Weibull method has performed well for decision making .

  6. COP Evaluation for a Membrane Liquid Desiccant Air Conditioning System Using Four Different Heating Equipment

    OpenAIRE

    Abdel-Salam, Ahmed; Simonson, Carey

    2015-01-01

    Liquid desiccant air conditioning (LDAC) is a promising technology in terms of energy efficiency, comfort and indoor air quality. The major components of a LDAC system are the dehumidifier and regenerator. The most commonly used design of dehumidifiers/regenerators is the packed-bed, which might result in the entrainment of desiccant droplets in air streams. A promising solution for the entrainment of desiccant droplets in air streams is to use a liquid-to-air membrane energy exchanger (LAMEE...

  7. Reconciling Indoor Air Quality and Energy Efficiency in Air-Conditioned Classrooms: Case Studies for Portugal and Macao

    OpenAIRE

    Rogério Duarte; Ingride Beltrão-Coelho

    2013-01-01

    Growing awareness on the subject of classroom’s indoor air quality and concerns regarding the probable link between indoor air quality, student’s attendance and academic performance, support recent legislation limiting classroom’s indoor pollutant concentrations. A consequence of this legislation is the generalized shift towards air-conditioned classrooms and increased budgets for schools energy running costs. According to the scientific literature, demand control ventilation systems are suit...

  8. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    International Nuclear Information System (INIS)

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  9. Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving

    International Nuclear Information System (INIS)

    The variable refrigerant flow (VRF) and variable air volume (VAV) combined air conditioning system can solve the problem of the VRF system in outdoor air ventilation while taking advantage of its high part load energy efficiency. Energy performance of the combined air conditioning system can also be optimized by joint control of both the VRF and the VAV parts. A model-based online optimal control strategy for the combined air conditioning system is presented. Simplified adaptive models of major components of the combined air conditioning system are firstly developed for predicting system performances. And a cost function in terms of energy consumption and thermal comfort is constructed. Genetic algorithm is used to search for the optimal control sets. The optimal control strategy is tested and evaluated through two case studies based on the simulation platform. Results show that the optimal strategy can effectively reduce energy consumption of the combined air conditioning system while maintaining acceptable thermal comfort. - Highlights: • A VRF and VAV combined system is proposed. • A model-based online optimal control strategy is proposed for the combined system. • The strategy can reduce energy consumption without sacrificing thermal comfort. • Novel simplified adaptive models are firstly developed for the VRF system

  10. Influences of the Indoor Environment on Heat, Air and Moisture Conditions in The Building Component: Boundary Conditions Modeling

    DEFF Research Database (Denmark)

    Steskens, Paul Wilhelmus Maria Hermanus; Rode, Carsten; Janssen, Hans

    Current models to predict heat, air and moisture (HAM) conditions in building components assume uniform boundary conditions, both for the temperature and relative humidity of the air in an indoor space as well as for the surface transfer coefficients. Such models cannot accurately predict the HAM...... conditions in the component and on the surface of the component with non-uniform air temperature or relative humidity distributions in an indoor space. Moreover, the heat and moisture surface transfer coefficients strongly depend on the local air velocity, local temperature, water-material interactions and...... used to investigate this influence. The research showed that the indoor environmental conditions and local airflow velocity have a relatively large influence on the predicted HAM conditions in a building component. The influence of the convective surface heat transfer coefficient on the HAM performance...

  11. COMPOSITION CHANGES IN REFRIGERANT BLENDS FOR AUTOMOTIVE AIR CONDITIONING

    Science.gov (United States)

    Three refrigerant blends used to replace CFC-12 in automotive air conditioners were evaluated for composition changes due to typical servicing and leakage. When recommended service procedures were followed, changes in blend compositions were relatively small. Small changes in b...

  12. Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation

    Directory of Open Access Journals (Sweden)

    Haslinda Mohamed Kamar

    2012-03-01

    Full Text Available A semi-empirical model for simulating thermal and energy performance of an automotive air-conditioning (AAC system in passenger vehicles has been developed. The model consists of two sections, namely empirical evaporator correlations and dynamic load simulation. The correlations used consider sensible and latent heat transfer performance of the evaporator coil. The correlations were obtained from the experimental data of actual air conditioning system for a compact size passenger car. The sensible heat transfer correlation relates the evaporator air off dry-bulb temperature to inlet air dry-bulb temperature, humidity ratio, evaporator air velocity, condenser inlet air dry-bulb temperature, condenser air velocity and compressor speed. The latent heat transfer correlation relates the coil air-off humidity ratio to the same six independent variables. The dynamic load simulation model was developed based on the z-transfer function method with a one-minute time step. The cooling load calculations were performed using heat gain weighting factors. Heat extraction rate and cabin air dry-bulb temperature calculations were carried out using air temperature weighting factors. The empirical evaporator sensible and latent heat transfer correlations were embedded in the loads calculation program to enable the determination of evaporator inlet and outlet air conditions, the cabin air temperature and relative humidity. Comparisons with road test data indicated that the program was capable of predicting the performance of the automotive air-conditioning system with reasonable accuracy.

  13. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source of ...

  14. Cooling Performance Characteristics on Mobile Air-Conditioning System for Hybrid Electric Vehicles

    OpenAIRE

    Ho-Seong Lee; Moo-Yeon Lee

    2013-01-01

    This study investigates the cooling performance characteristics of the mobile air-conditioning system using R744 (CO2) for the hybrid electric vehicle as an alternative to both the R-134a and the conventional air-conditioning system. The developed air-conditioning system is operated with an electric driven compressor in the battery driving mode and a belt driven compressor in the engine driving mode. The cooling performance characteristics of the developed system have been analyzed by experim...

  15. Application of an Integrated Heat Recovery Technology for Domestic Hot Water Supply System and Air Conditioning

    OpenAIRE

    Chen Yan; Zhang Yufeng

    2013-01-01

    This study is to design an integrated heat recovery and air conditioner system and to investigate the feasibility and the potential performance of this system in changing conditions. Different season conditions and operating modes are studied based on the items of one hotel. In winter, heat recovered from wastewater is used on water heating and air condition and the surplus energy of air conditioner system is used on hot water system in summer. Dynamic energy ...

  16. MAGNETOHYDRODYNAMICS: A METHOD FOR PERFORMANCE ENHANCEMENT IN AIR CONDITIONING AND REFRIGERATION

    OpenAIRE

    N.S.Mane; , H.M.Dange; P. P. Awate

    2015-01-01

    The refrigeration and air conditioning system having low energy consumption and environment friendliness is the main focus of the research department Refrigeration and Air conditioning industry and technical institutes. Efficiency of the refrigeration or air conditioning system working on vapour compression refrigeration cycle can be increased by using the Magneto hydrodynamic principles. Many researchers indicated that the behavior of the refrigerant flowing through vapour compre...

  17. Performance advancement of solar air-conditioning through integrated system design for building

    International Nuclear Information System (INIS)

    This study is to advance the energy performance of solar air-conditioning system through appropriate component integration from the absorption refrigeration cycle and proper high-temperature cooling. In the previous studies, the solar absorption air-conditioning using the working pair of water – lithium bromide (H2O–LiBr) is found to have prominent primary energy saving than the conventional compression air-conditioning for buildings in the hot-humid climate. In this study, three integration strategies have been generated for solar cooling, namely integrated absorption air-conditioning; integrated absorption-desiccant air-conditioning; and integrated absorption-desiccant air-conditioning for radiant cooling. To realize these ideas, the working pair of ammonia – water (NH3–H2O) was used in the absorption cycle, rather than H2O–LiBr. As such, the evaporator and the condenser can be separate from the absorption refrigeration cycle for the new configuration of various integrated design alternatives. Through dynamic simulation, the year-round primary energy saving of the proposed integration strategies for solar NH3–H2O absorption air-conditioning systems could be up to 50.6% and 25.5%, as compared to the conventional compression air-conditioning and the basic solar H2O–LiBr absorption air-conditioning respectively. Consequently, carbon reduction of building air-conditioning can be achieved more effectively through the integrated system design in the hot and humid cities. - Highlights: • Three integration strategies, IAAU, IADAU and IADAU-RC, are proposed to advance solar air-conditioning. • NH3–H2O is adopted for absorption refrigeration instead of H2O–LiBr. • Separate evaporator and condenser, desiccant cooling and radiant cooling are designed for IADAU-RC. • IADAU-RC can have 50.6% primary energy saving against the conventional air-conditioning

  18. Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions

    International Nuclear Information System (INIS)

    The vertical open refrigerated display cabinets suffer alterations of their thermal performance and energy efficiency due to variations of ambient air conditions. The air curtain provides an aerothermodynamics insulation effect that can be evaluated by the thermal entrainment factor calculation as an engineering approximation or by the calculus of all sensible and latent thermal loads. This study presents the variation of heat transfer rate and thermal entrainment factor obtained through experimental tests carried out for different ambient air conditions, varying air temperature, relative humidity, velocity and its direction relatively to the display cabinet frontal opening. The thermal entrainment factor are analysed and compared with the total sensible and latent heats results for the experimental tests. From an engineering point of view, it is concluded that thermal entrainment factor cannot be used indiscriminately, although its use is suitable to design better cabinet under the same climate class condition.

  19. The system of thermoelectric air conditioning based on permeable thermoelements

    Directory of Open Access Journals (Sweden)

    Cherkez R. G.

    2009-04-01

    Full Text Available There is thermoelectric air conditioner unit on the basis of permeable cooling thermoelements presented. In thermoelectric air conditioner unit the thermoelectric effects and the Joule–Thomson effect have been used for the air stream cooling. There have been described the method of temperature distribution analysis, the determinations of energy conversion power characteristics and design style of permeable thermoelement with maximum coefficient of performance described. The results of computer analysis concerning the application of the thermoelement legs material on the basis of Bi2Te3 have shown the possibility of coefficient of performance increase by a factor of 1,6—1,7 as compared with conventional thermoelectric systems.

  20. The effects of air stoichiometry and air excess ratio on the transient response of a PEMFC under load change conditions

    International Nuclear Information System (INIS)

    Highlights: • Effects of controlling parameters on the transient response of a PEMFC are studied. • The transient response is measured by varying air stoichiometry and air excess ratio. • Voltage drop, undershoot, and voltage fluctuation are analyzed under the load change. • Optimal air stoichiometry and air excess ratio are suggested for stable operation. - Abstract: The transient response of a proton exchange membrane fuel cell (PEMFC) is an important issue for transportation applications. The objective of this study is to investigate the effects of operating and controlling parameters on the transient response of a PEMFC for achieving more stable cell performance under load change conditions. The transient response of a PEMFC was measured and analyzed by varying air stoichiometry, air humidity, and air excess ratio (AER). The optimal air stoichiometry and AER were determined to minimize the voltage drop, undershoot, and voltage fluctuation under the load change, while maintaining high cell performance. Based on the present data, the optimal air stoichiometry was determined to be between 2.0 and 2.5, and the optimal AER was suggested to be between 1.65 and 2.0

  1. New principle of organization of working process of air conditioning systems at railway and sea transport

    OpenAIRE

    Andrey KRAJNIUK; Aleksander KRAJNIUK

    2008-01-01

    An indispensable component of ensuring safe control of railway and sea transport in conditions of hot climate is maintenance of comfortable temperature of air in control cabins and living spaces. Now the interest is restored to use the Air Refrigerating Plants (ARP) as they have a wide potential of low-temperature cooling without use of ozone-destructive cooling agents prohibited by decision of the Montreal meeting. At the same time, air conditioning installations on the basis of turbo-expand...

  2. Simulation of Solar Air-Conditioning System with Salinity Gradient Solar Pond

    OpenAIRE

    Safwan Kanan, Jonathan Dewsbury, Gregory Lane-Serff

    2015-01-01

    In hot dry climates, due to the high demand for space air conditioning during summer and the abundance of solar radiation, solar air conditioning is a promising approach to reduce the energy consumption and negative environmental impact of buildings. Solar cooling systems have used various types of collectors to drive chillers. In this paper, a salinity gradient solar pond is suggested as a collector to drive an absorption chiller, to provide cool air for a house during hot and dry weather. A...

  3. 24 CFR 3280.813 - Outdoor outlets, fixtures, air-conditioning equipment, etc.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Outdoor outlets, fixtures, air-conditioning equipment, etc. 3280.813 Section 3280.813 Housing and Urban Development Regulations Relating to... Electrical Systems § 3280.813 Outdoor outlets, fixtures, air-conditioning equipment, etc. (a)...

  4. Automotive Air Conditioning and Heating; Automotive Mechanics (Advanced): 9047.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to provide the student with all the foundations necessary to become employable in the automotive air conditioning and heating trade. The course of study includes an orientation to the world of work, the elementary physics of air conditioning and heating, and laboratory experiments…

  5. Criterion-Referenced Test (CRT) Items for Air Conditioning, Heating and Refrigeration.

    Science.gov (United States)

    Davis, Diane, Ed.

    These criterion-referenced test (CRT) items for air conditioning, heating, and refrigeration are keyed to the Missouri Air Conditioning, Heating, and Refrigeration Competency Profile. The items are designed to work with both the Vocational Instructional Management System and Vocational Administrative Management System. For word processing and…

  6. Application of Fuzzy Comprehensive Evaluation to Air-conditioning Competitive Power Analysis

    Institute of Scientific and Technical Information of China (English)

    LU Congda; LIU Gaojin; JIANG Shaofei; LV Chaoqun

    2006-01-01

    As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD), customer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product designing. Lots of information in the process of this research is fuzzy and uncertain, but traditional QFD can not deal with it well. Fuzzy theory can solve the problem. So a fuzzy model for analyzing product competitive power is formulated in this paper to improve traditional QFD, after that it is applied to analyze air-conditioning competitive power. When air-conditioning competitive power is analyzed using this model, firstly the importance weight of the customer requirements of air-conditioning is determined using the Analytic Hierarchy Process (AHP) weighting process, then air-conditioning competitive power is evaluated using fuzzy comprehensive evaluation. It is proved that the model is feasible and has good applicability.

  7. Opportunities to Reduce Air-Conditioning Loads Through Lower Cabin Soak Temperatures

    International Nuclear Information System (INIS)

    Air-conditioning loads can significantly reduce electric vehicle (EV) range and hybrid electric vehicle (HEV) fuel economy. In addition, a new U. S. emissions procedure, called the Supplemental Federal Test Procedure (SFTP), has provided the motivation for reducing the size of vehicle air-conditioning systems in the United States. The SFTP will measure tailpipe emissions with the air-conditioning system operating. If the size of the air-conditioning system is reduced, the cabin soak temperature must also be reduced, with no penalty in terms of passenger thermal comfort. This paper presents the impact of air-conditioning on EV range and HEV fuel economy, and compares the effectiveness of advanced glazing and cabin ventilation. Experimental and modeled results are presented

  8. Reduction of air ion mobility to standard conditions

    Science.gov (United States)

    Tammet, H.

    1998-06-01

    The Langevin rule of the reduction of air ion mobility is adequate in case of zero-size ions. An alternative is the Stokes-Millikan equation that is adequate in the limit of macroscopic charged particles. The temperature variation of air ion mobility predicted by the Stokes-Millikan equation radically contradicts the Langevin rule. The temperature and pressure variation of air ion mobility is examined by using a new semiempirical model that describes the transition from the kinetic theory to the Stokes-Millikan equation. The model is valid in full mobility range. It allows to calculate at first the size of an ion according to the measured mobility and then the standard mobility according to the size. The ascent of the temperature-mobility curve on a logarithmic chart approaches the Langevin value of 1 only at very high mobilities not found in the atmosphere. The value of the ascent is 0.6 in the case of small ions of the mobility of 1.5 cm2 V-1 s-1 which brings about a considerable error when using the Langevin rule. It is recommended to store the natural values of the mobility in databases together with the values of temperature and pressure and to definitely indicate the method when the reduced mobilities are presented in publications.

  9. Influence of Cooling to Heating Load Ratio on Optimal Supply Water and Air Temperatures in an Air Conditioning System

    Science.gov (United States)

    Karino, Naoki; Shiba, Takashi; Yokoyama, Ryohei; Ito, Koichi

    In planning an air conditioning system, supply water and air temperatures are important factors from the viewpoint of energy saving and cost reduction. For example, lower temperature supply water and air for space cooling reduce the coefficient of performance of a refrigeration machine, and increase the thickness of heat insulation material. However, they enable larger temperature differences, and reduce equipment sizes and power demand. It is also an important subject to evaluate the effect of the supply water and air temperatures on energy saving and cost reduction on the annual basis by considering not only cooling but also heating loads. The purposes of this paper are to propose an optimal planning method for an air conditioning system with large temperature difference, and to analyze the effect of supply water and air temperatures on the long-term economics through a numerical study for an office building. As a result, it is shown that the proposed method effectively determines supply water and air temperatures, and the influence of the cooling to heating load ratio on the long-term economics is clarified.

  10. Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

    2014-09-01

    Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

  11. Calculation of the Chilling Requirement for Air Conditioning in the Excavation Roadway

    Directory of Open Access Journals (Sweden)

    Yueping Qin

    2015-10-01

    Full Text Available To effectively improve the climate conditions of the excavation roadway in coal mine, the calculation of the chilling requirement taking air conditioning measures is extremely necessary. The temperature field of the surrounding rock with moving boundary in the excavation roadway was numerically simulated by using finite volume method. The unstable heat transfer coefficient between the surrounding rock and air flow was obtained via the previous calculation. According to the coupling effects of the air flow inside and outside air duct, the differential calculation mathematical model of air flow temperature in the excavation roadway was established. The chilling requirement was calculated with the selfdeveloped computer program for forecasting the required cooling capacity of the excavation roadway. A good air conditioning effect had been observed after applying the calculated results to field trial, which indicated that the prediction method and calculation procedure were reliable.

  12. The Design of Research Laboratories. Part I: A General Assessment. Part II: Air Conditioning and Conditioned Rooms.

    Science.gov (United States)

    Legget, R. F.; Hutcheon, N. B.

    Design factors in the planning of research laboratories are described which include--(1) location, (2) future expansion, (3) internal flexibility, (4) provision of services, (5) laboratory furnishing, (6) internal traffic, (7) space requirements, and (8) building costs. A second part discusses air-conditioning and conditioned rooms--(1)…

  13. A simulation Model of the Reactor Hall Ventilation and air Conditioning Systems of ETRR-2

    International Nuclear Information System (INIS)

    Although the conceptual design for any system differs from one designer to another. each of them aims to achieve the function of the system required. the ventilation and air conditioning system of reactors hall is one of those systems that really differs but always dose its function for which it is designed. thus, ventilation and air conditioning in some reactor hall constitute only one system whereas in some other ones, they are separate systems. the Egypt Research Reactor-2 (ETRR-2)represents the second type. most studies conducted on ventilation and air conditioning simulation models either in traditional building or for research rectors show that those models were not designed similarly to the model of the hall of ETRR-2 in which ventilation and air conditioning constitute two separate systems.besides, those studies experimented on ventilation and air conditioning simulation models of reactor building predict the temperature and humidity inside these buildings at certain outside condition and it is difficult to predict when the outside conditions are changed . also those studies do not discuss the influences of reactor power changes. therefore, the present work deals with a computational study backed by infield experimental measurements of the performance of the ventilation and air conditioning systems of reactor hall during normal operation at different outside conditions as well as at different levels of reactor power

  14. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo.

    Science.gov (United States)

    Nishimura, Takeshi; Mori, Futoshi; Hanida, Sho; Kumahata, Kiyoshi; Ishikawa, Shigeru; Samarat, Kaouthar; Miyabe-Nishiwaki, Takako; Hayashi, Misato; Tomonaga, Masaki; Suzuki, Juri; Matsuzawa, Tetsuro; Matsuzawa, Teruo

    2016-03-01

    We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD) with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved "Out of Africa" to explore the more severe climates of

  15. Impaired Air Conditioning within the Nasal Cavity in Flat-Faced Homo.

    Directory of Open Access Journals (Sweden)

    Takeshi Nishimura

    2016-03-01

    Full Text Available We are flat-faced hominins with an external nose that protrudes from the face. This feature was derived in the genus Homo, along with facial flattening and reorientation to form a high nasal cavity. The nasal passage conditions the inhaled air in terms of temperature and humidity to match the conditions required in the lung, and its anatomical variation is believed to be evolutionarily sensitive to the ambient atmospheric conditions of a given habitat. In this study, we used computational fluid dynamics (CFD with three-dimensional topology models of the nasal passage under the same simulation conditions, to investigate air-conditioning performance in humans, chimpanzees, and macaques. The CFD simulation showed a horizontal straight flow of inhaled air in chimpanzees and macaques, contrasting with the upward and curved flow in humans. The inhaled air is conditioned poorly in humans compared with nonhuman primates. Virtual modifications to the human external nose topology, in which the nasal vestibule and valve are modified to resemble those of chimpanzees, change the airflow to be horizontal, but have little influence on the air-conditioning performance in humans. These findings suggest that morphological variation of the nasal passage topology was only weakly sensitive to the ambient atmosphere conditions; rather, the high nasal cavity in humans was formed simply by evolutionary facial reorganization in the divergence of Homo from the other hominin lineages, impairing the air-conditioning performance. Even though the inhaled air is not adjusted well within the nasal cavity in humans, it can be fully conditioned subsequently in the pharyngeal cavity, which is lengthened in the flat-faced Homo. Thus, the air-conditioning faculty in the nasal passages was probably impaired in early Homo members, although they have survived successfully under the fluctuating climate of the Plio-Pleistocene, and then they moved "Out of Africa" to explore the more

  16. DESIGN OF A VRF AIR CONDITIONING SYSTEM WITH ENERGY CONSERVATION ON COMMERCIAL BUILDING

    Directory of Open Access Journals (Sweden)

    Shaik Gulam Abul Hasan*

    2015-07-01

    Full Text Available Today, the field if air conditioning design is more technologically challenging than ever before. While design innovations and product improvements promise sleeker, more versatile, more powerful and more energy – efficient air conditioners, the challenge today lies identifying the most appropriate product, or mix of products, for the application at hand. Indeed, today the emphasis is no more on understanding air conditioning products but on creating solutions and not just solutions, but customized solutions that suit specific cooling need of specific business and establishments. The consultant or designer who understands the dynamics of those clients business is more likely to offer better long term cooling solutions than who does not. Every air conditioning application has its own special needs and provided its own challenges. Airports, hotels, shopping malls, office complexes and banks need uniform comfort cooling in every corner of their sprawling spaces and activities involving computers, electronics, aircraft products, precision manufacturing, communication networks and operation in hospitals, infect many areas of programming will come to a halt, so air conditioning is no longer a luxury but an essential part of modern living. There are various stages in the complete design of an air conditioning system. One of the important modules in the process is the duct design. The efficient duct design process enables the proper supply of air quantity, equal distribution of air at every corner of the Air conditioned space. Further the proper designing ensures minimum losses and hence energy conservation is obtained. In the present paper design of Air conditioning is done by using VRF (Variable Refrigerant Flow for a commercial building. The main aim of his project is to conserve the energy by using VRF techniques when compared to conventional chille

  17. Analysis and simulation of mobile air conditioning system coupled with engine cooling system

    International Nuclear Information System (INIS)

    Many components of the mobile air conditioning system and engine cooling system are closely interrelated and make up the vehicle climate control system. In the present paper, a vehicle climate control system model including air conditioning system and engine cooling system has been proposed under different operational conditions. All the components have been modeled on the basis of experimental data. Based on the commercial software, a computer simulation procedure of the vehicle climate control system has been developed. The performance of the vehicle climate control system is simulated, and the calculational data have good agreement with experimental data. Furthermore, the vehicle climate control simulation results have been compared with an individual air conditioning system and engine cooling system. The influences between the mobile air conditioning system and the engine cooling system are discussed

  18. Desiccant Enhanced Evaporative Air-Conditioning (DEVap): Evaluation of a New Concept in Ultra Efficient Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Woods, J.; Burch, J.; Boranian, A.; Merrigan, T.

    2011-01-01

    NREL has developed the novel concept of a desiccant enhanced evaporative air conditioner (DEVap) with the objective of combining the benefits of liquid desiccant and evaporative cooling technologies into an innovative 'cooling core.' Liquid desiccant technologies have extraordinary dehumidification potential, but require an efficient cooling sink. DEVap's thermodynamic potential overcomes many shortcomings of standard refrigeration-based direct expansion cooling. DEVap decouples cooling and dehumidification performance, which results in independent temperature and humidity control. The energy input is largely switched away from electricity to low-grade thermal energy that can be sourced from fuels such as natural gas, waste heat, solar, or biofuels.

  19. A packed bed dehumidifier/regenerator for solar air conditioning with liquid desiccants

    Science.gov (United States)

    Factor, H. M.; Grossman, G.

    1980-01-01

    A packed column air-liquid contactor has been studied in application to air dehumidification and regeneration in solar air conditioning with liquid desiccants. A theoretical model has been developed to predict the performance of the device under various operating conditions. Computer simulations based on the model are presented which indicate the practical range of air to liquid flux ratios and associated changes in air humidity and desiccant concentration. An experimental apparatus has been constructed and experiments performed with Monoethylene Glycol (MEG) and Lithium Bromide as desiccants. MEG experiments have yielded inaccurate results and have pointed out some practical problems associated with the use of Glycols. LiBr experiments show very good agreement with the theoretical model. Preheating of the air is shown to greatly enhance desiccant regeneration. The packed column yields good results as a dehumidifier/regenerator, provided pressure drop can be reduced with the use of suitable packing.

  20. Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

    Directory of Open Access Journals (Sweden)

    Haslinda Mohamed Kamar

    2013-01-01

    Full Text Available This paper presents results of a parametric study performed on an automotive air-conditioning (AAC system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA, on the dry-bulb temperature and specific humidity of the air inside the passengers cabin, and on the evaporator coil cooling load of the AAC system. Results of the parametric study show that increasing the supply air flow rate reduces the dry-bulb temperature of the cabin air, increases both the specific humidity of the air and the evaporator coil load. Increasing the number of occupants in the passenger cabin causes the cabin air temperature, specific humidity and the evaporator coil load to increase. Increasing the vehicle speed causes the specific humidity of the cabin air and the evaporator coil cooling load to increase but the dry-bulb temperature of the air is not significantly affected. Increasing the fractional fresh air intake (XOA also increases the cabin air specific humidity and the evaporator coil cooling load.

  1. System and method for conditioning intake air to an internal combustion engine

    Energy Technology Data Exchange (ETDEWEB)

    Sellnau, Mark C.

    2015-08-04

    A system for conditioning the intake air to an internal combustion engine includes a means to boost the pressure of the intake air to the engine and a liquid cooled charge air cooler disposed between the output of the boost means and the charge air intake of the engine. Valves in the coolant system can be actuated so as to define a first configuration in which engine cooling is performed by coolant circulating in a first coolant loop at one temperature, and charge air cooling is performed by coolant flowing in a second coolant loop at a lower temperature. The valves can be actuated so as to define a second configuration in which coolant that has flowed through the engine can be routed through the charge air cooler. The temperature of intake air to the engine can be controlled over a wide range of engine operation.

  2. An analysis of asthma hospitalizations, air pollution, and weather conditions in Los Angeles County, California

    OpenAIRE

    Delamater, Paul L.; Andrew O. Finley; Banerjee, Sudipto

    2012-01-01

    There is now a large body of literature supporting a linkage between exposure to air pollutants and asthma morbidity. However, the extent and significance of this relationship varies considerably between pollutants, location, scale of analysis, and analysis methods. Our primary goal is to evaluate the relationship between asthma hospitalizations, levels of ambient air pollution, and weather conditions in Los Angeles (LA) County, California, an area with a historical record of heavy air pollut...

  3. Air conditioning in a tropical climate: Impacts upon European residents in Darwin, Australia

    Science.gov (United States)

    Auliciems, A.; Dedear, R.

    1986-09-01

    The efficacy of current practices in air conditioning is investigated in the two monsoonal seasons in Darwin. Assessment is made of atmospheric parameters, clothing, metabolic rate. Some 1000 questionnaires are applied dealing with adaptations, health perceptions and preferences as related to air cooling and ventilation. The findings are discussed with reference to energy balance calculations and current models of psychological control in thermoregulation. The results indicate that Darwin's population is considerably overcooled, and contrary to assumptions and practice, air conditioning is not desired in office buildings during the “Dry”. In the home, air conditioning is not regarded as essential. The indications are that a rationalization of air cooling to comply with natural variability in warmth would lead to a significant reduction in energy consumption, and an overall enhancement to the health and comfort of the population through the greater ventilation rates that would be economically feasible were design temperatures lifted.

  4. Optimal heat rejection pressure in transcritical carbon dioxide air conditioning and heat pump systems

    DEFF Research Database (Denmark)

    Liao, Shengming; Jakobsen, Arne

    1998-01-01

    Due to the urgent need for environmentally benign refrigerants, the use of the natural substance carbon dioxide in refrigeration systems has gained more and more attention. In systems such as automobile air-conditioners and heat pumps, owing to the relatively high heat rejection temperatures, the...... dioxide air conditioning or heat pump systems and for intelligent controlling such systems....

  5. Temperature and Humidity Independent Control Research on Ground Source Heat Pump Air Conditioning System

    Science.gov (United States)

    Chen, G.; Wang, L. L.

    Taking green demonstration center building air conditioning system as an example, this paper presents the temperature and humidity independent control system combined with ground source heat pump system, emphasis on the design of dry terminal device system, fresh air system and ground source heat pump system.

  6. Method for acquiring part load distribution coefficient of air conditioning system

    Institute of Scientific and Technical Information of China (English)

    丁勇; 李百战; 谭颖

    2009-01-01

    This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizing monthly energy consumption data of the entire year as the analysis object,this paper identifies data distribution,verifies distribution characteristics and analyzes distribution probability density for the issue of running time distribution ratio of air conditioning system in part load zones in the whole operation period,thus providing a basic calculation basis for an overall analysis of energy efficiency of air conditioning system. In view of the general survey of public building energy consumption carried by the government of Chongqing,this paper takes the governmental office building as an example,the part load ratio coefficient corresponding to practical running of air conditioning system of governmental office building in Chongqing is obtained by utilizing the above probability analysis and the solving method of probability density function. By utilizing the ratio coefficient obtained using this method,the part load coefficient with any running ratio of air conditioning system can be obtained according to the requirement of analysis,which can be used in any load ratio for analyzing running energy efficiency of air conditioning system.

  7. Intelligent energy management control of vehicle air conditioning system coupled with engine

    International Nuclear Information System (INIS)

    Vehicle Air Conditioning (AC) systems consist of an engine powered compressor activated by an electrical clutch. The AC system imposes an extra load to the vehicle's engine increasing the vehicle fuel consumption and emissions. Energy management control of the vehicle air conditioning is a nonlinear dynamic system, influenced by uncertain disturbances. In addition, the vehicle energy management control system interacts with different complex systems, such as engine, air conditioning system, environment, and driver, to deliver fuel consumption improvements. In this paper, we describe the energy management control of vehicle AC system coupled with vehicle engine through an intelligent control design. The Intelligent Energy Management Control (IEMC) system presented in this paper includes an intelligent algorithm which uses five exterior units and three integrated fuzzy controllers to produce desirable internal temperature and air quality, improved fuel consumption, low emission, and smooth driving. The three fuzzy controllers include: (i) a fuzzy cruise controller to adapt vehicle cruise speed via prediction of the road ahead using a Look-Ahead system, (ii) a fuzzy air conditioning controller to produce desirable temperature and air quality inside vehicle cabin room via a road information system, and (iii) a fuzzy engine controller to generate the required engine torque to move the vehicle smoothly on the road. We optimised the integrated operation of the air conditioning and the engine under various driving patterns and performed three simulations. Results show that the proposed IEMC system developed based on Fuzzy Air Conditioning Controller with Look-Ahead (FAC-LA) method is a more efficient controller for vehicle air conditioning system than the previously developed Coordinated Energy Management Systems (CEMS). - Highlights: ► AC interacts: vehicle, environment, driver components, and the interrelationships between them. ► Intelligent AC algorithm which uses

  8. The new exchangers in refrigeration and air, conditioning applications

    Energy Technology Data Exchange (ETDEWEB)

    Marvillet, Ch. [CEA, 38 - Grenoble (France). GRETh

    1997-12-31

    The investigation carried out by the `heat exchangers` network has revealed a number of points which should be noted here at the beginning of this presentation. It has been observed that most of today`s products (fin and tube heat exchangers) are designed along traditional lines. However despite this `conservatism`, a lot of attention is found on the technical and innovative techniques used in other areas of the world (particularly in Japan). Moreover, some of these innovative techniques (micro fin tubes, louvered fins) tend to be more frequently applied than others, and their gradual introduction into products which are `made in the EEC` is to be expected. The purpose of this paper is to respond, at least partially, to the interest shown by the industries contacted. during this investigation in these new techniques. In the first chapter, an overview of the information available today on high performance thermal heat exchange surfaces will be given. Micro-fin tubes and louvered fins will be the two surfaces considered in the first part of this document. According to this investigation, the fin and tube heat exchanger remains the only product available today for evaporating and condensing refrigerant applications using air as the fluid to be treated. Other technological solutions exist, however; brazed fin and plate heat exchangers commonly used in applications where compactness is an essential quality will be examined in the second part of this document. Moreover, the use of fluids which will replace CFCS in the years to come, and the possible comeback of ammonia will certainly have consequences on the design of evaporators and condensers. In the third part of this document the effects of these changes on fin and tube heat exchangers will be evaluated, and the first published results of the use of substitution fluids will be discussed. (author) 16 refs.

  9. hermetically sealed compressor unit, temperature level, mathematical model, marine air conditioning syste

    OpenAIRE

    Lytosh, Olena V.; Dorosh, Vadym S.

    2014-01-01

    The mathematical model and calculation method of the temperature level of the hermetically sealed compressor unit for the marine self-contained air conditioners taking into account the operating conditions and machine design parameters have been given.

  10. Evaluating Membrane Processes for Air Conditioning; Highlights in Research and Development, NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-06-01

    This NREL Highlight discusses a recent state-of-the-art review of membrane processes for air conditioning that identifies future research opportunities. This highlight is being developed for the June 2015 S&T Alliance Board meeting.

  11. Temperature and humidity independent control (THIC) of air-conditioning system

    CERN Document Server

    Liu, Xiaohua; Zhang, Tao

    2014-01-01

    This book presents the main components of the Temperature and Humidity Independent Control (THIC) of air-conditioning systems, including dehumidification devices, high-temperature cooling devices and indoor terminal devices.

  12. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    OpenAIRE

    Silvia Cocchi; Sonia Castellucci; Andrea Tucci

    2013-01-01

    The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling), through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP) uses the shallow ground a...

  13. Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System

    OpenAIRE

    Jing-Nang Lee; Tsung-Min Lin; Chien-Chih Chen

    2014-01-01

    This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for con...

  14. Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation

    OpenAIRE

    Haslinda Mohamed Kamar; Mohd Yusoff Senawi; Nazri Kamsah

    2012-01-01

    A semi-empirical model for simulating thermal and energy performance of an automotive air-conditioning (AAC) system in passenger vehicles has been developed. The model consists of two sections, namely empirical evaporator correlations and dynamic load simulation. The correlations used consider sensible and latent heat transfer performance of the evaporator coil. The correlations were obtained from the experimental data of actual air conditioning system for a compact size passenger car. The se...

  15. Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature

    OpenAIRE

    Jing-Nang Lee; Chien-Chih Chen; Chen-Ching Ting

    2014-01-01

    The article presents numerical analysis of exergy for air-conditioning influenced by ambient temperature. The model of numerical simulation uses an integrated air conditioning system exposed in varied ambient temperature to observe change of the four main devices, the compressor, the condenser, the capillary, and the evaporator in correspondence to ambient temperature. The analysis devices of the four devices’s exergy influenced by the varied ambient temperature and found that the...

  16. New Energy-Efficient Electromagnetic Clutch for Automotive Air Conditioning Compressors

    OpenAIRE

    Baumgart, Rico; van der Seylberg, Frank; Aurich, Joerg; von Unwerth, Thomas

    2012-01-01

    Even if the air conditioning is switched off, the internal combustion engine in today’s cars continues to drive the common compressor. To avoid resulting power losses, the automotive industry aspires to apply electromagnetic clutches. When the air conditioning is used, however, CO2-emission increases significantly because the electromag-netic coil consumes electricity. The CO2-reduction per year is consequently very low, which is why new compressor clutches were developed that do not require ...

  17. Solar technology assessment project. Volume 4: Solar air conditioning: Active, hybrid and passive

    Science.gov (United States)

    Yellott, J. I.

    1981-04-01

    The status of absorption cycle solar air conditioning and the Rankine cycle solar cooling system is reviewed. Vapor jet ejector chillers, solar pond based cooling, and photovoltaic compression air conditioning are also briefly discussed. Hybrid solar cooling by direct and indirect evaporative cooling, and dehumidification by desiccation are described and discussed. Passive solar cooling by convective and radiative processes, evaporative cooling by passive processes, and cooling with roof ponds and movable insulation are reviewed. Federal and state involvement in solar cooling is discussed.

  18. Exergy and Thermoeconomic Analysis for an Underground Train Station Air-Conditioning Cooling System

    OpenAIRE

    Ke Yang Liao; Yew Khoy Chuah

    2016-01-01

    The necessity of air-conditioning causes the enormous energy use of underground train stations. Exergy and thermoeconomic analysis is applied to the annual operation of the air-conditioning system of a large underground train station in Taiwan. The current installation and the monitored data are taken to be the base case, which is then compared to three different optimized designs. The total revenue requirement levelized cost rate and the total exergy destruction rate are used to evaluate the...

  19. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor;

    2014-01-01

    evaluated as deodorant materials neutralising ammonia in air. The deodorant material efficiency was tested in a special experimental set-up consisting of a straight pipe section, an ammonia gas generator, a fan and a textile frame. The deodorant materials, placed in the pipe, were exposed to a flow of air......Unpleasant odor is a serious problem in hospitals and elderly facilities. One of the unpleasant odors is ammonia originating from human urine and sweat. The air cleaning efficiency of porous activated carbon fiber fabric which has been treated with acid, and porous activated carbon fiber fabric was...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity...

  20. Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

    OpenAIRE

    Haslinda Mohamed Kamar; Nazri Kamsah; Mohd Yusoff Senawi

    2013-01-01

    This paper presents results of a parametric study performed on an automotive air-conditioning (AAC) system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA), on the dry-bulb temperature and specific humidity of the air inside the passengers cabin, and on the evaporator coil cooling load of the AAC system. Results of the parametric study show that increas...

  1. Solar energy contribution to the energy demand for air conditioning system in an office building under Tripoli climate conditions

    OpenAIRE

    Musbah Mohamed H.; Živković Branislav D.; Kosi Franc F.; Abdulgalil Mohamed M.; Sretenović Aleksandra A.

    2014-01-01

    The feasibility of solar assisted air conditioning in an office building under Tripoli weather conditions is investigated in this paper. A single-effect lithium bromide absorption cycle powered by means of flat-plate solar collectors was modeled in order to predict the potential of the solar energy share. The cooling load profile was generated by using an detailed hourly based program and Typical meteorological year for Tripoli. System performance and solar...

  2. Ice Storage Air-Conditioning System Simulation with Dynamic Electricity Pricing: A Demand Response Study

    Directory of Open Access Journals (Sweden)

    Chi-Chun Lo

    2016-02-01

    Full Text Available This paper presents an optimal dispatch model of an ice storage air-conditioning system for participants to quickly and accurately perform energy saving and demand response, and to avoid the over contact with electricity price peak. The schedule planning for an ice storage air-conditioning system of demand response is mainly to transfer energy consumption from the peak load to the partial-peak or off-peak load. Least Squares Regression (LSR is used to obtain the polynomial function for the cooling capacity and the cost of power consumption with a real ice storage air-conditioning system. Based on the dynamic electricity pricing, the requirements of cooling loads, and all technical constraints, the dispatch model of the ice-storage air-conditioning system is formulated to minimize the operation cost. The Improved Ripple Bee Swarm Optimization (IRBSO algorithm is proposed to solve the dispatch model of the ice storage air-conditioning system in a daily schedule on summer. Simulation results indicate that reasonable solutions provide a practical and flexible framework allowing the demand response of ice storage air-conditioning systems to demonstrate the optimization of its energy savings and operational efficiency and offering greater energy efficiency.

  3. Sustainability Challenges from Climate Change and Air Conditioning Use in Urban Areas

    Directory of Open Access Journals (Sweden)

    Karin Lundgren

    2013-07-01

    Full Text Available Global climate change increases heat loads in urban areas causing health and productivity risks for millions of people. Inhabitants in tropical and subtropical urban areas are at especial risk due to high population density, already high temperatures, and temperature increases due to climate change. Air conditioning is growing rapidly, especially in South and South-East Asia due to income growth and the need to protect from high heat exposures. Studies have linked increased total hourly electricity use to outdoor temperatures and humidity; modeled future predictions when facing additional heat due to climate change, related air conditioning with increased street level heat and estimated future air conditioning use in major urban areas. However, global and localized studies linking climate variables with air conditioning alone are lacking. More research and detailed data is needed looking at the effects of increasing air conditioning use, electricity consumption, climate change and interactions with the urban heat island effect. Climate change mitigation, for example using renewable energy sources, particularly photovoltaic electricity generation, to power air conditioning, and other sustainable methods to reduce heat exposure are needed to make future urban areas more climate resilient.

  4. Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System

    Institute of Scientific and Technical Information of China (English)

    SU Shun-yu; ZHANG Chun-zhi; CHEN Jian

    2009-01-01

    This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-con-ditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of dif-ferent refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-eonditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump-The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.

  5. Fault-tolerant supervisory control of VAV air-conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.-F.; Dexter, A. [Department of Engineering Science, University of Oxford, Oxford (United Kingdom)

    2001-07-01

    The paper describes a supervisory control scheme that adapts to the presence of degradation faults and minimises any resulting increase in energy consumption or deterioration in occupant comfort. Since there is a high degree of uncertainty associated with the results of any fault identification scheme in information-poor systems of this type, the supervisory control scheme uses fuzzy models to predict the control performance and a computationally undemanding optimisation scheme to determine the most appropriate set-points. The fault-tolerant control scheme is developed and evaluated using a detailed computer simulation of a multi-zone, variable-air-volume (VAV), air-conditioning system. The fuzzy models relate the performance of the terminal-boxes, the air-handling unit and the chiller to fuzzy descriptions of the cooling load, the supply air and chilled water temperature set-points, and the amount of air-side and water-side fouling. Results are presented that demonstrate the ability of the fuzzy models to predict the performance and show how the power consumption of the air-conditioning system varies with set-point changes and the presence of both water-side and air-side fouling. The main factors that determine the suitability of a particular air-conditioning system for fault-tolerant control are also discussed. (author)

  6. Ventilation and air conditioning facility turbine building in nuclear power plant

    International Nuclear Information System (INIS)

    In the facility of the present invention, the exhaustion capacity of an exhaustion blower, an exhaustion duct or a main exhaustion stack are decreased to reduce cost for buildings and running cost. That is, the facility of the present invention has an exhaustion port at a position higher than an air supply port disposed to the outer wall of an operation floor of a turbine building. During usual operation, ventilation and air conditioning are conducted for the operation floor by natural circulating ventilation in which air is supplied from the air supply port and exhausted from the exhaustion port. Upon periodical inspection, ventilation and air conditioning are conducted for the operation floor by supplying air from the air supply port and exhausting it from the main exhaustion stack. When air is exhausted from the main exhaustion stack, a means for disposing an exhaustion system exclusively used for the operation floor having a separately disposed exhaustion blower connected to the main exhaustion stack is used or a means capable of selectively communicating the operation floor with a contamination area exhaustion system in the turbine building is used. With such a constitution, the capacity of the exhaustion system is reduced during both of the usual operation and periodical inspection. Further, upon periodical inspections, if air is exhausted from the main exhaustion stack by way of the exhaustion system exclusively used for the turbine building operation floor, the balance for the total amount of airflow is not lost. (I.S.)

  7. Investigation on regeneration and energy storage characteristics of a solar liquid desiccant air-conditioning system

    Institute of Scientific and Technical Information of China (English)

    SHI Mingheng; DU Bin; ZHAO Yun

    2007-01-01

    Solar liquid desiccant air-conditioner is a new air-conditioning system in which liquid desiccant can be regenerated by solar energy and energy can be stored in the form of chemical energy in the liquid desiccant.In this paper regeneration and energy storage characteristics were studied theoretically and experimentally.Two criterion equations for heat and mass transfer in the regeneration process were obtained.The main factors that influence the regeneration process were analyzed.A principal solar liquid desiccant air-conditioning system under energy storage operating mode is proposed.

  8. Energy-smart calculation of thermal loads in mobile and stationary heating, ventilation, air conditioning, and refrigeration systems

    OpenAIRE

    Fayazbakhsh, Mohammad Ali

    2015-01-01

    The energy consumption by heating, ventilation, air conditioning, and refrigeration systems forms a large portion of the total energy usage in buildings. Vehicle fuel consumption and emissions are also significantly affected by air conditioning. Air conditioning is also a critical system for hybrid electric vehicles and electric vehicles as the second most energy consuming system after the electric motor. Proper design and efficient operation of air conditioning systems require accurate calcu...

  9. Effective Ventilation Parameters and Thermal Comfort Study of Air-conditioned Offices

    Directory of Open Access Journals (Sweden)

    Roonak Daghigh

    2009-01-01

    Full Text Available The study presents objective and subjective studies of thermal comfort levels and ventilation characteristics of two air-conditioned postgraduate study offices. The observations were performed at the offices of Department of Electrical and Electronic Engineering, in University Putra Malaysia. Thermal comfort variables were measured while the students answered a survey on their sensation of the indoor climate. Concurrently, tracer gas analysis, based on concentration decay method, is employed to determine air exchange rate, age of air and air exchange effectiveness. During the air conditioner is working, the study offices had not conditions within the comfort zone, of ASHRAE standard 55 causing occupants to report cold thermal sensations and the objective data analysis showed that the offices were uncomfortable. The thermal neutralities were significantly higher that proposed by ASHRAE Standard 55:1992. The monitored air exchange rates are indicated that the provisions of outside air for ventilation based on design occupancy are adequate for these two study offices. In addition, questionnaires were completed by the students in order to provide a subjective assessment of thermal comfort and indoor air quality. Finally, the outcomes of over 30 surveys for each office responses to the thermal comfort questions are presented and discussed.

  10. HUMAN RESOURCE MANAGEMENT PRACTICES IN REFRIGERATION AND AIR CONDITIONING INDUSTRY IN INDIA

    Directory of Open Access Journals (Sweden)

    Dr.Nisar Ahamad Nalband

    2010-11-01

    Full Text Available Over the last 150 years or so, refrigeration’s great strides offered us ways to preserve and cool food, other substances and ourselves. Refrigeration brought distant production centers. It tore down the barriers of climates and seasons. And while it helped to rev up industrial process, it became an industry itself It is understood that the refrigeration and air conditioning industry has been a promising industry for the development of Indian economy and one of the old industry in India too. Indian refrigeration and air conditioning Industry has been playing a very vital role in the growth of Indian economy. The employees of refrigeration and airconditioning Industry are mostly knowledge workers. Knowledge workers are skilled, use intuition and past experience, as well as creating the new knowledge which resides in their heads and which is also evident in their commitment, attitude and relationship. However, the projected growth of Indian refrigeration and air conditioning industry will largely depend upon the Industries’ ability to manage its human resources Though research has been done on HRD/HRM in refrigeration and air conditioning industry, a considerable study has yet to be made on Indian refrigeration and air conditioning industry. The literature on Indian refrigeration and air conditioning industry consists mainly in the form of Books, Annual Reports, and other web based reports. The Technical, Engineering and Management journals also published articles on the subject. A great amount of research work has to be carried on in the country. There is a promising and potential scope for the researchers to investigate more and inform more to Indian air conditioning and refrigeration industry to adapt to new techniques of HRM/HRD.

  11. 75 FR 6338 - Protection of Stratospheric Ozone: New Substitute in the Motor Vehicle Air Conditioning Sector...

    Science.gov (United States)

    2010-02-09

    ...EPA issued a proposed rule in the Federal Register of October 19, 2009, proposing to find HFO-1234yf acceptable, subject to use conditions as a substitute for CFC-12 in motor vehicle air conditioning. The proposed substitute is a non-ozone-depleting substance and consequently does not contribute to stratospheric ozone depletion. In response to requests from several stakeholders and to allow......

  12. An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices

    International Nuclear Information System (INIS)

    Maintaining an acceptable indoor environmental quality (IEQ) for air-conditioned office buildings consumes a considerable amount of thermal energy. This study correlates thermal energy consumption with the overall occupant acceptance of IEQ in some air-conditioned offices. An empirical expression of an IEQ index associated with thermal comfort, indoor air quality, aural and visual comfort is used to benchmark the offices. Employing input parameters obtained from the building stocks of Hong Kong, the office portfolios regarding the thermal energy consumption and the IEQ index are determined by Monte Carlo simulations. In particular, an energy-to-acceptance ratio and an energy-to-IEQ improvement ratio are proposed to measure the performance of energy consumption for the IEQ in the air-conditioned offices. The ratios give the thermal energy consumption corresponding to a desirable percentage of IEQ acceptances and to an IEQ upgrade, respectively. The results showed a non-linear increasing trend of annual thermal energy consumption for IEQ improvement at the offices of higher IEQ benchmarks. The thermal energy consumption for visual comfort and indoor air quality would also be significant in these offices. This study provides useful information that incorporates the IEQ in air-conditioned offices into the development of performance evaluation measures for thermal energy consumption.

  13. Improving Forecast Skill by Assimilation of Quality-controlled AIRS Temperature Retrievals under Partially Cloudy Conditions

    Science.gov (United States)

    Reale, O.; Susskind, J.; Rosenberg, R.; Brin, E.; Riishojgaard, L.; Liu, E.; Terry, J.; Jusem, J. C.

    2007-01-01

    The National Aeronautics and Space Administration (NASA) Atmospheric Infrared Sounder (AIRS) on board the Aqua satellite has been long recognized as an important contributor towards the improvement of weather forecasts. At this time only a small fraction of the total data produced by AIRS is being used by operational weather systems. In fact, in addition to effects of thinning and quality control, the only AIRS data assimilated are radiance observations of channels unaffected by clouds. Observations in mid-lower tropospheric sounding AIRS channels are assimilated primarily under completely clear-sky conditions, thus imposing a very severe limitation on the horizontal distribution of the AIRS-derived information. In this work it is shown that the ability to derive accurate temperature profiles from AIRS observations in partially cloud-contaminated areas can be utilized to further improve the impact of AIRS observations in a global model and forecasting system. The analyses produced by assimilating AIRS temperature profiles obtained under partial cloud cover result in a substantially colder representation of the northern hemisphere lower midtroposphere at higher latitudes. This temperature difference has a strong impact, through hydrostatic adjustment, in the midtropospheric geopotential heights, which causes a different representation of the polar vortex especially over northeastern Siberia and Alaska. The AIRS-induced anomaly propagates through the model's dynamics producing improved 5-day forecasts.

  14. Effect of Air Relative Humidity Harvest on Soil Moisture Content under Moroccan Climatic Conditions

    Directory of Open Access Journals (Sweden)

    El Khadir Lakhal

    2015-04-01

    Full Text Available In this work, we aim to analyse the effect of the harvest of air relative humidity on soil water content. Some experiments were conducted on hilly areas with various hypsographic and microclimatic conditions greatly affecting daily fluctuations of air relative humidity. The metrological data’s were obtained by using a Campbell Scientific equipments station recorder on data loggers every half hour. Time Domain Reflectometers (TDR is used for calculating water content at different soil layers. The effect of many parameters such as: minimal and maximal air atmospheric humidity, potential of soil water and minimal temperature of air on harvesting air relative humidity is also discussed. The experimental results indicate that soil moisture content in the upper soil layer fluctuates with the same manner to diurnal fluctuation of relative air humidity. These fluctuations due to the harvest of relative air humidity decreased with increasing soil depth and daily amplitude of relative air humidity. The water adsorbed according to this phenomenon increased with increasing maximal relative and decreasing minimal temperature. The contribution of this soil water collected is about 40% of losses due to evaporation process. The correlation between principal climatic data and soil water adsorption by harvest relative air humidity is presented in this paper in order to incorporate it in the total water balance during water infiltration.

  15. Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station

    Institute of Scientific and Technical Information of China (English)

    LI Wei; NA Yanling

    2007-01-01

    Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer.

  16. Development of a Ventilation and Air-conditioning System using Fixed Bed Desiccant Units

    Science.gov (United States)

    Miyazaki, Takahiko; Akisawa, Atsushi; Shindoh, Shinji; Masazumi, Godo; Takeshi, Takatsuka; Hamamoto, Yoshinori; Mori, Hideo

    The study investigated fixed bed desiccant units for ventilation and air-conditioning. The system mainly dehumidifies the outdoor fresh air to be supplied to an air-conditioned room. Hence, the airconditioning load of the air-conditioner in the room can be mitigated. Several adsorbents were compared from the viewpoints of humidity ratio at the outlet of the desiccant unit, dehumidified quantity per unit volume, and dehumidified quantity per unit adsorbent mass. The performance of the desiccant unit was predicted by simulation which was validated by comparison with experiment. The results revealed the most suitable adsorbent to reduce the desiccant unit size. It was also found that the humidity ratio at the outlet of the desiccant unit could be lowered by shortening the dimensionless switching time.

  17. OPTIMIZATION OF MICROWAVE AND AIR DRYING CONDITIONS OF QUINCE (CYDONIA OBLONGA, MILLER USING RESPONSE SURFACE METHODOLOGY

    Directory of Open Access Journals (Sweden)

    Cem Baltacioglu

    2015-03-01

    Full Text Available Effects of slice thickness of quince (Cydonia oblonga Miller , microwave incident power and air drying temperature on antioxidant activity and total phenolic content of quince were investigated during drying in microwave and air drying. Optimum conditions were found to be: i for microwave drying, 285 W and 4.14 mm thick (maximum antioxidant activity and 285 W and 6.85 mm thick (maximum total phenolic content, and ii for air drying, 75 ºC and 1.2 mm thick (both maximum antioxidant activity and total phenolic content. Drying conditions were optimized by using the response surface methodology. 13 experiments were carried out considering incident microwave powers from 285 to 795 W, air temperature from 46 to 74 ºC and slice thickness from 1.2 to 6.8 mm.

  18. The analysis and improvement of the humidity problem on air-condition system of SSRF

    International Nuclear Information System (INIS)

    In this work, efforts were made to solve the problem of high relative humidity in some areas of the Shanghai Synchrotron Radiation Facility (SSRF). Based on data analysis, theoretical demonstration and field tests, we found that the problem of high humidity was caused by two factors. The high humidity problem was solved by appropriate measures of keeping the actual operation load match to the design load of the air-conditioning systems and minimizing the outdoor air infiltration. (authors)

  19. Preliminary thermodynamic design of a stirling cooler for mobile air conditioning systems : Technical report

    OpenAIRE

    Kaufmann, André; Ylinen, Hannu

    2015-01-01

    The present discussion on refrigerants used in mobile air conditioning (MAC) units leads to the question whether a stirling cycle based heat pump could replace the present technology. An experimental and simulative study is carried out to determine the design parameters of such a heat pump. It is found that the targeted power density cannot be reached with air as a working fluid. The power require-ments would lead to machine sizes too large for a passenger vehicle.

  20. Simulation and Optimization of a Solar Driven Air Conditioning System for Indian Cities

    OpenAIRE

    Sharma, Dev

    2013-01-01

    Simulation and Optimization of a Solar Driven Air Conditioning System for Indian Cities Conventional air-conditioners need high grade energy i.e. electricity, which in India, is primarily produced from fossil fuels. In spite of several emission restraints exercised by many countries under Kyoto protocol, energy consumption and pollution levels are higher than ever. Therefore, an assessment from the ecological point of view needs to be implemented as the greenhouse gases effect remains a threa...

  1. Ventilation conditions and air-borne bacteria and particles in operating theatres: proposed safe economies.

    OpenAIRE

    Clark, R. P.; Reed, P. J.; Seal, D V; Stephenson, M. L.

    1985-01-01

    Concentrations of air-borne bacteria and particles have been measured in turbulently ventilated operating theatres in full flow, half flow and zero flow conditions. Increased air-borne challenge produced by human activity and by mechanical cleaning procedures is demonstrated: die-away of this contamination is shown to be related to the ventilation rate. Ventilation can be reduced or turned off at night and during weekends, and cleaning can also be carried out, without increased risk of infect...

  2. OPTIMIZATION OF MICROWAVE AND AIR DRYING CONDITIONS OF QUINCE (CYDONIA OBLONGA, MILLER) USING RESPONSE SURFACE METHODOLOGY

    OpenAIRE

    Cem Baltacioglu

    2015-01-01

    Effects of slice thickness of quince (Cydonia oblonga Miller) , microwave incident power and air drying temperature on antioxidant activity and total phenolic content of quince were investigated during drying in microwave and air drying. Optimum conditions were found to be: i) for microwave drying, 285 W and 4.14 mm thick (maximum antioxidant activity) and 285 W and 6.85 mm thick (maximum total phenolic content), and ii) for air drying, 75 ºC and 1.2 mm thick (both maximum antioxidant activit...

  3. Simulation and analysis of a novel liquid desiccant air-conditioning system

    International Nuclear Information System (INIS)

    In this work a novel energy efficient air-conditioning system utilizing lithium chloride (LiCl) solution as liquid desiccant has been proposed and simulated. The simulation of this system is mainly formulated with two packed columns, one for regenerating the weak desiccant and the other for the dehumidification of ambient air. The air is first dehumidified in the dehumidifier and then sensibly cooled in the indirect and direct evaporative coolers. First and second laws of thermodynamics have been used to analyze the effect of five key variables on the performance of the system. High efficiency could be achieved if proper values of these variables are selected.

  4. Fast simulation of temperature distribution in air conditioned rooms by using proper orthogonal decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Sempey, A.; Inard, C.; Allery, C. [Laboratoire d' etude des phenomenes de transfert appliques au batiment (LEPTAB), Universite de La Rochelle, pole sciences et technologie, avenue Michel Crepeau, 17042 La Rochelle cedex 1 (France); Ghiaus, C. [Centre Thermique de Lyon (CETHIL) UMR 5008, INSA Lyon, 9, rue de la Physique, 69621 Villeurbanne cedex (France)

    2009-02-15

    Real-time control of air conditioning needs dynamic models of temperature distribution and air velocity field in rooms. Complete models, based on computational fluid dynamics (CFD), give this information, but they are too time-consuming for real-time applications. Therefore, a reduced model is needed. In mixed convection, when the air temperature has negligible variations, the velocity field may be considered fixed. In this case, the size of a CFD model may be reduced by solving only the energy balance equation, then putting this equation in the form of state-space and finally by reducing its order by proper orthogonal decomposition (POD). This algorithm was applied to a room equipped with a fan coil. Four fixed airflow fields, corresponding to negligible air temperature variation, were considered, resulting in four airflow patterns: the air jet sticks to the ceiling and reaches the opposite wall, the air jet falls before reaching the opposite wall, the air jet reaches the ceiling without extending along it, and the air jet falls before reaching the ceiling. The reduced model obtained from these airflow patterns was validated by comparing with CFD results for step variation of inlet temperature. As the order of the reduced model is always lower than seven, it may be used for real-time control applications. (author)

  5. Solar air conditioning: introduction and basics; Solare Klimatisierung Einfuehrung und Grundlagen

    Energy Technology Data Exchange (ETDEWEB)

    Albers, J. [Inst. fuer Erhaltung und Modernisierung von Bauwerken e.V. an der Technische Univ. Berlin (Germany)

    2005-07-01

    A considerable increase of the cold energy demand is expected world-wide in the coming years. Electrically operated cold compression plants are currently used at the most in order to meet the cold energy demand resulting also in a rising electric current and primary energy demand. This can have an effect on the supply security as well as on the change of the world climate. Therefore more alternative methods of cold generation are supposed to be applied in the future. The following contribution describes that plant systems for solar air conditioning (SAC-systems) are an attractive and feasible technology that demands engineering but can also be further developed and can make an important contribution to the target mentioned above. First an overview is provided of conventional air conditioning technology and of the expected development tendencies with regard to cold demand. Afterwards the currently available solar air conditioning methods and their possible applications are explained. (orig.)

  6. Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-07-01

    Full Text Available The article presents numerical analysis of exergy for air-conditioning influenced by ambient temperature. The model of numerical simulation uses an integrated air conditioning system exposed in varied ambient temperature to observe change of the four main devices, the compressor, the condenser, the capillary, and the evaporator in correspondence to ambient temperature. The analysis devices of the four devices’s exergy influenced by the varied ambient temperature and found that the capillary has unusual increasing exergy loss vs. increasing ambient temperature in comparison to the other devices. The result shows that reducing exergy loss of the capillary influenced by the ambient temperature is the key for improving working efficiency of an air-conditioning system when influence of the ambient temperature is considered. The higher ambient temperature causes the larger pressure drop of capillary and more exergy loss.

  7. An Expert Fault Diagnosis System for Vehicle Air Conditioning Product Development

    Science.gov (United States)

    Tan, C. F.; Tee, B. T.; Khalil, S. N.; Chen, W.; Rauterberg, G. W. M.

    2015-09-01

    The paper describes the development of the vehicle air-conditioning fault diagnosis system in automotive industries with expert system shell. The main aim of the research is to diagnose the problem of new vehicle air-conditioning system development process and select the most suitable solution to the problems. In the vehicle air-conditioning manufacturing industry, process can be very costly where an expert and experience personnel needed in certain circumstances. The expert of in the industry will retire or resign from time to time. When the expert is absent, their experience and knowledge is difficult to retrieve or lost forever. Expert system is a convenient method to replace expert. By replacing the expert with expert system, the accuracy of the processes will be increased compared to the conventional way. Therefore, the quality of product services that are produced will be finer and better. The inputs for the fault diagnosis are based on design data and experience of the engineer.

  8. Prediction of thermal sensation in non-air-conditioned buildings in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  9. Impact of the electric compressor for automotive air conditioning system on fuel consumption and performance analysis

    Science.gov (United States)

    Zulkifli, A. A.; Dahlan, A. A.; Zulkifli, A. H.; Nasution, H.; Aziz, A. A.; Perang, M. R. M.; Jamil, H. M.; Misseri, M. N.

    2015-12-01

    Air conditioning system is the biggest auxiliary load in a vehicle where the compressor consumed the largest. Problem with conventional compressor is the cooling capacity cannot be control directly to fulfill the demand of thermal load inside vehicle cabin. This study is conducted experimentally to analyze the difference of fuel usage and air conditioning performance between conventional compressor and electric compressor of the air conditioning system in automobile. The electric compressor is powered by the car battery in non-electric vehicle which the alternator will recharge the battery. The car is setup on a roller dynamometer and the vehicle speed is varied at 0, 30, 60, 90 and 110 km/h at cabin temperature of 25°C and internal heat load of 100 and 400 Watt. The results shows electric compressor has better fuel consumption and coefficient of performance compared to the conventional compressor.

  10. Extension of the PMV model to non-air-conditioned building in warm climates

    DEFF Research Database (Denmark)

    Fanger, Povl Ole; Toftum, Jørn

    2002-01-01

    The PMV model agrees well with high-quality field studies in buildings with HVAC systems, situated in cold, temperate and warm climates, studied during both summer and winter. In non-air-conditioned buildings in warm climates, occupants may sense the warmth as being less severe than the PMV...... predicts. The main reason is low expectations, but a metabolic rate that is estimated too high can also contribute to explaining the difference. An extension of the PMV model that includes an expectancy factor is introduced for use in non-air-conditioned buildings in warm climates. The extended PMV model...... agrees well with quality field studies in non-air-conditioned buildings of three continents....

  11. SUMMARY OF ELECTRIC SERVICE COSTS FOR TOTALLY AIR CONDITIONED SCHOOLS PREPARED FOR HOUSTON INDEPENDENT SCHOOL DISTRICT, MAY 31, 1967.

    Science.gov (United States)

    WHITESIDES, M.M.

    THIS REPORT IS A COMPILATION OF DATA ON ELECTRIC AIR CONDITIONING COSTS, OPERATIONS AND MAINTENANCE. AIR CONDITIONING UNITS ARE COMPARED IN TERMS OF ELECTRIC VERSUS NON-ELECTRIC, AUTOMATIC VERSUS OPERATED, AIR COOLED VERSUS WATER COOLED, RECIPROCATING VERSUS CENTRIFUGAL COMPRESSORS, SPACE AND NOISE, REHEAT, MAINTENANCE AND ORIGINAL COST. DATA ARE…

  12. Proposed energy-efficient air-conditioning system using liquid desiccant

    Energy Technology Data Exchange (ETDEWEB)

    Kinsara, Adnan A.; Al-Rabghi, Omar M. [King Abdulaziz Univ., Thermal Engineering Dept., Jeddah (Saudi Arabia); Elsayed, Moustafa M. [Kuwait Univ., Mechanical Engineering Dept., Safat (Kuwait)

    1996-10-01

    In this work, an energy-efficient system is proposed to reduce energy consumption in air-conditioning (A/C) systems using CaCl{sub 2} solution as a liquid desiccant. The proposed system consists mainly of two packed beds, a heat pump, air washers and a cooling coil. Mathematical modeling of various components and fluid properties of the proposed system was undertaken. A computer program was prepared to study the system performance under different conditions. The proposed system was found to be more energy-efficient than a conventional A/C system. (author)

  13. Ice Storage Air-Conditioning System Simulation with Dynamic Electricity Pricing: A Demand Response Study

    OpenAIRE

    Chi-Chun Lo; Shang-Ho Tsai; Bor-Shyh Lin

    2016-01-01

    This paper presents an optimal dispatch model of an ice storage air-conditioning system for participants to quickly and accurately perform energy saving and demand response, and to avoid the over contact with electricity price peak. The schedule planning for an ice storage air-conditioning system of demand response is mainly to transfer energy consumption from the peak load to the partial-peak or off-peak load. Least Squares Regression (LSR) is used to obtain the polynomial function for the c...

  14. Energy savings potential of a hybrid desiccant dehumidification air conditioning system in Beirut

    International Nuclear Information System (INIS)

    In this work, the transient performance of a hybrid desiccant vapor compression air conditioning system is numerically simulated for the ambient conditions of Beirut. The main feature of this hybrid system is that the regenerative heat needed by the desiccant wheel is partly supplied by the condenser dissipated heat while the rest is supplied by an auxiliary gas heater. The hybrid air conditioning system of the present study replaces a 23 kW vapor compression unit for a typical office in Beirut characterized by a high latent load. The vapor compression subsystem size in the hybrid air conditioning system is reduced to 15 kW at the peak load when the regeneration temperature was fixed at 75 deg. C. Also the sensible heat ratio of the combined hybrid system increased from 0.47 to 0.73. Based on hour by hour simulation studies for a wide range of recorded ambient conditions of Beirut city, this paper predicts the annual energy consumption of the hybrid system in comparison with the conventional vapor compression system for the entire cooling season. The annual running costs savings for the hybrid system is 418.39 USD for a gas cost price of 0.141 USD/kg. The pay back period of the hybrid system is less than five years when the initial cost of the hybrid air conditioning system priced an additional 1712.00 USD. Hence, for a 20-year life cycle, the life cycle savings of the hybrid air conditioning system are 4295.19 USD

  15. Operational experience of air washer based ventilation system for power conditioning system of Indus-2

    International Nuclear Information System (INIS)

    Indus-2 Synchrotron Accelerator requires high quality conditioned uninterrupted AC mains power for their smooth and reliable operation. Three units of 1670 kVA and one unit of 1100 kVA capacity rotary uninterruptible power conditioning systems (UPS) were installed and commissioned. These UPS units require dust free and cool ambient conditions for smooth operation. In order to meet the ventilation requirements, an evaporative cooling system of 80000 cubic meter/hour capacity with filtration units was designed, installed and commissioned in February 2011 and is operational on round-the-clock basis. Evaporative cooling scheme was chosen as has various advantages over a refrigerated system like lower initial capital costs, lower energy usage, lower running costs, less greenhouse gas and it does not contribute to ozone depletion. The ventilation system filters the environment air in stages up to 5 micron level and being conditioned with an automatic controlled soft water circulating system with cooling pads. An instrumentation and control scheme is included in the system to provide the automation requirements for operating 24 x 7 through the year. All the mechanical, hydraulic and electrical devices are maintained by providing preventive maintenance work without affecting the accelerator machine operation. Availability and reliability of the system was analysed based on the failure data. In Year 2014, the ventilation system was upgraded to accommodate standby blower unit, coupling unit and improved quality of supply air with new air conditioning devices. The control panel monitors the condition of air in the UPS hall and maintainsup to 28°C air temperature and 85% maximum relative humidity in round-the clock shift with more than 98% operational reliability. In this paper, we present design philosophy, installation, instrumentation, testing, operation experience and availability of the ventilation system for Power Conditioning System, Indus complex. (author)

  16. Preliminary verification of instantaneous air temperature estimation for clear sky conditions based on SEBAL

    Science.gov (United States)

    Zhu, Shanyou; Zhou, Chuxuan; Zhang, Guixin; Zhang, Hailong; Hua, Junwei

    2016-03-01

    Spatially distributed near surface air temperature at the height of 2 m is an important input parameter for the land surface models. It is of great significance in both theoretical research and practical applications to retrieve instantaneous air temperature data from remote sensing observations. An approach based on Surface Energy Balance Algorithm for Land (SEBAL) to retrieve air temperature under clear sky conditions is presented. Taking the meteorological measurement data at one station as the reference and remotely sensed data as the model input, the research estimates the air temperature by using an iterative computation. The method was applied to the area of Jiangsu province for nine scenes by using MODIS data products, as well as part of Fujian province, China based on four scenes of Landsat 8 imagery. Comparing the air temperature estimated from the proposed method with that of the meteorological station measurement, results show that the root mean square error is 1.7 and 2.6 °C at 1000 and 30 m spatial resolution respectively. Sensitivity analysis of influencing factors reveals that land surface temperature is the most sensitive to the estimation precision. Research results indicate that the method has great potentiality to be used to estimate instantaneous air temperature distribution under clear sky conditions.

  17. Optimization of microwave-assisted hot air drying conditions of okra using response surface methodology.

    Science.gov (United States)

    Kumar, Deepak; Prasad, Suresh; Murthy, Ganti S

    2014-02-01

    Okra (Abelmoschus esculentus) was dried to a moisture level of 0.1 g water/g dry matter using a microwave-assisted hot air dryer. Response surface methodology was used to optimize the drying conditions based on specific energy consumption and quality of dried okra. The drying experiments were performed using a central composite rotatable design for three variables: air temperature (40-70 °C), air velocity (1-2 m/s) and microwave power level (0.5-2.5 W/g). The quality of dried okra was determined in terms of color change, rehydration ratio and hardness of texture. A second-order polynomial model was well fitted to all responses and high R(2) values (>0.8) were observed in all cases. The color change of dried okra was found higher at high microwave power and air temperatures. Rehydration properties were better for okra samples dried at higher microwave power levels. Specific energy consumption decreased with increase in microwave power due to decrease in drying time. The drying conditions of 1.51 m/s air velocity, 52.09 °C air temperature and 2.41 W/g microwave power were found optimum for product quality and minimum energy consumption for microwave-convective drying of okra. PMID:24493879

  18. Air-conditioning and antibiotics: Demand management insights from problematic health and household cooling practices

    International Nuclear Information System (INIS)

    Air-conditioners and antibiotics are two technologies that have both been traditionally framed around individual health and comfort needs, despite aspects of their use contributing to social health problems. The imprudent use of antibiotics is threatening the capacity of the healthcare system internationally. Similarly, in Australia the increasing reliance on air-conditioning to maintain thermal comfort is contributing to rising peak demand and electricity prices, and is placing an inequitable health and financial burden on vulnerable heat-stressed households. This paper analyses policy responses to these problems through the lens of social practice theory. In the health sector, campaigns are attempting to emphasise the social health implications of antibiotic use. In considering this approach in relation to the problem of air-conditioned cooling and how to change the ways in which people keep cool during peak times, our analysis draws on interviews with 80 Australian households. We find that the problem of peak electricity demand may be reduced through attention to the social health implications of air-conditioned cooling on very hot days. We conclude that social practice theory offers a fruitful analytical route for identifying new avenues for research and informing policy responses to emerging health and environmental problems. - Highlights: • Over-use of antibiotics and air-conditioning has social health implications. • Focusing on financial incentives limits the potential of demand management programs. • Explaining peak demand to households shifts the meanings of cooling practices. • Emphasising the social health implications of antibiotics and air-conditioning may resurrect alternative practices. • Analysing policy with social practice theory offers insights into policy approaches

  19. A dynamic model for air-based photovoltaic thermal systems working under real operating conditions

    International Nuclear Information System (INIS)

    Highlights: • A dynamic model suitable for air-based photovoltaic thermal (PVT) systems is presented. • The model is validated with PVT data from two unique buildings. • The simulated output variables match very well with the experimental data. • The performance of the PVT system under changing working condition is analysed. - Abstract: In this paper a dynamic model suitable for simulating real operating conditions of air-based photovoltaic thermal (PVT) systems is presented. The performance of the model is validated by using the operational data collected from the building integrated photovoltaic (PVT) systems installed in two unique buildings. The modelled air outlet temperature and electrical power match very well with the experimental data. In Solar Decathlon house PVT, the average (RMS) error in air outlet temperatures was 4.2%. The average (RMS) error in electrical power was also 4.2%. In the Sustainable Buildings Research Centre PVT, the average errors (RMS) of PV and air temperatures were 3.8% and 2.2%, respectively. The performance of the PVT system under changing working condition is also analysed in this paper. The analysis includes the effect of ambient air temperature, air inlet temperature, air flow rate and solar irradiation on thermal, electrical, first law and second law efficiencies. Both the thermal and the 1st law efficiencies almost linearly increased with the increase of the ambient temperature. However, the PVT electrical efficiency and the second law efficiency decreased with the increase of the ambient temperature. All efficiencies expect the second law efficiency decreased with increase of the PVT air inlet temperature. The second law efficiency first increased and then reduced. With increasing the air flow rate all the efficiencies increased. The electrical and second law efficiencies become less sensitive when the air flow rate exceeded 300 l/s. Both the thermal and the 1st law efficiencies decreased while the electrical

  20. Sulfate Attack Resistance of Air-entrained Silica Fume Concrete under Dry-Wet Cycle Condition

    Institute of Scientific and Technical Information of China (English)

    YANG Jiansen; WANG Peiming; LI Haoxin; YANG Xu

    2016-01-01

    Based on the erosion resistant coefficient, the effects of water-cement ratio, air-entrained, silica fume content and sand ratio on the sulfate attack resistance of air-entrained silica fume concrete were studied by orthogonal experiments in order to explore its sulfate attack resistance under dry-wet condition. A more signiifcant model of concrete resistance to sulfate attack was also established, thus this work provided a strategy reference for quantitative design of sulfate attack resistant concrete. The experimental results show that dry-wet cycle deteriorates the concrete resistance to the sulfate attack, and leads to the remarkable declines of concrete strength and sulfate resistance. Air bubbles in the air-entrained silica fume concrete lower and delay the damage resulted from the crystallization sulfate salt. However this delay gradually disappears when most of the close bubbles are breached by the alternative running of the sulfate salt crystallization and the permeating pressure, and then the air bubbles are iflled with sulfate salt crystallization. The concrete is provided with the strongest sulfate resistance when it is prepared with the 0.47 water-binder ratio, 6.0% air-entrained, 5% silica fume and 30% sand ratio. The erosion resistant coefifcientsK80 andK150 of this concrete are increased by 9%, 7%, 9%, and 5% respectively as compared with those of concretes without silica fume and air entraining.

  1. Energy and Greenhouse Gas Emission Assessment of Conventional and Solar Assisted Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    Xiaofeng Li

    2015-11-01

    Full Text Available Energy consumption in the buildings is responsible for 26% of Australia’s greenhouse gas emissions where cooling typically accounts for over 50% of the total building energy use. The aim of this study was to investigate the potential for reducing the cooling systems’ environmental footprint with applications of alternative renewable energy source. Three types of cooling systems, water cooled, air cooled and a hybrid solar-based air-conditioning system, with a total of six scenarios were designed in this work. The scenarios accounted for the types of power supply to the air-conditioning systems with electricity from the grid and with a solar power from highly integrated building photovoltaics (BIPV. Within and between these scenarios, systems’ energy performances were compared based on energy modelling while the harvesting potential of the renewable energy source was further predicted based on building’s detailed geometrical model. The results showed that renewable energy obtained via BIPV scenario could cover building’s annual electricity consumption for cooling and reduce 140 tonnes of greenhouse gas emissions each year. The hybrid solar air-conditioning system has higher energy efficiency than the air cooled chiller system but lower than the water cooled system.

  2. Residential solar air conditioning: Energy and exergy analyses of an ammonia–water absorption cooling system

    International Nuclear Information System (INIS)

    Large scale heat-driven absorption cooling systems are available in the marketplace for industrial applications but the concept of a solar driven absorption chiller for air-conditioning applications is relatively new. Absorption chillers have a lower efficiency than compression refrigeration systems, when used for small scale applications and this restrains the absorption cooling system from air conditioning applications in residential buildings. The potential of a solar driven ammonia–water absorption chiller for residential air conditioning application is discussed and analyzed in this paper. A thermodynamic model has been developed based on a 10 kW air cooled ammonia–water absorption chiller driven by solar thermal energy. Both energy and exergy analyses have been conducted to evaluate the performance of this residential scale cooling system. The analyses uncovered that the absorber is where the most exergy loss occurs (63%) followed by the generator (13%) and the condenser (11%). Furthermore, the exergy loss of the condenser and absorber greatly increase with temperature, the generator less so, and the exergy loss in the evaporator is the least sensitive to increasing temperature. -- Highlights: • 10 kW solar thermal driven ammonia–water air cooled absorption chiller is investigated. • Energy and exergy analyses have been done to enhance the thermal performance. • Low driving temperature heat sources have been optimized. • The efficiencies of the major components have been evaluated

  3. Cleaning and air conditioning device for atmosphere in thermonuclear reactor chamber

    International Nuclear Information System (INIS)

    The device of the present invention removes tritium efficiently and attains ventilation and conditioning of a great amount of air flow. That is, there are disposed a humidity separator, a filter, a heater, a catalyst filled layer, a water jetting type humidifying heat insulation cooler and a cooler in this order from an inlet side (upstream) of contaminated room atmospheric gases. The catalyst filled layer, etc. are incorporated integrally into the ventilation air conditioning facility for ventilating air in the chamber of the thermonuclear reactor, to clean a tritium atmosphere at the same time. Accordingly, the device is made compact as a whole. A limit for the air flow rate owing to the use of the conventional catalyst tower and adsorbing tower is eliminated. Then a ventilating air conditioning for a great flow rate can be attained. Tritium is removed by cooling and dehumidification without using any adsorbent. Accordingly, an adsorbing tower is no more necessary and conventional regeneration operation is not required. As a result, space for installation is reduced, the system is simplified and the cost for construction and facility can be reduced. (I.S.)

  4. Droplets spectrum of air-assisted boom sprayers under different environmental and operational conditions

    Directory of Open Access Journals (Sweden)

    Robson S. Sasaki

    2016-01-01

    Full Text Available ABSTRACT During pesticide spraying, the psychrometric conditions of the air may cause evaporation of the droplets along their trajectory from the nozzle to the target. Thus, this study aimed to evaluate the effect of air psychrometric conditions and operating pressure on the droplet spectrum of air-assisted boom sprayers. The test was performed using a prototype equipped with an axial fan, a flow homogenizer, temperature and relative air humidity sensors, a spray nozzle and a gas-heating system to warm up the airflow. With the assembled system and the aid of a particle analyser, the JSF 11002 spray nozzle was evaluated with respect to droplet spectrum in four air psychrometric conditions (7, 14, 21 and 28 hPa and at four operating pressures (200, 300, 400 and 500 kPa. At the end, evaporation losses were observed during the sprayings. For a given operating pressure and for each increment of 1 hPa in vapor pressure deficit, there was a diameter reduction of approximately 0.0759, 0.518 and 1.514 μm for the parameters DV0.1, DV0.5 and DV0.9, respectively. The diameter of the droplets decreased as the operating pressure increased.

  5. Prediction of air temperature in the aircraft cabin under different operational conditions

    Directory of Open Access Journals (Sweden)

    Fišer J.

    2013-04-01

    Full Text Available This paper deals with the prediction of the air temperature in the aircraft cabin by means of Computational Fluid Dynamics. The simulations are performed on the CFD model which is based on geometry and cabin interior arrangement of the Flight Test Facility (FTF located at Fraunhofer IBP, Germany. The experimental test flights under three different cabin temperatures were done in FTF and the various data were gathered during these flights. Air temperature in the cabin was measured on probes located near feet, torso and head of each passenger and also surface temperature and air temperature distributed from inlets were measured. The data were firstly analysed in order to obtain boundary conditions for cabin surfaces and inlets. Then the results of air temperature from the simulations were compared with measured data. The suitability and accuracy of the CFD approach for temperature prediction is discussed.

  6. Prediction of air temperature in the aircraft cabin under different operational conditions

    Science.gov (United States)

    Volavý, F.; Fišer, J.; Nöske, I.

    2013-04-01

    This paper deals with the prediction of the air temperature in the aircraft cabin by means of Computational Fluid Dynamics. The simulations are performed on the CFD model which is based on geometry and cabin interior arrangement of the Flight Test Facility (FTF) located at Fraunhofer IBP, Germany. The experimental test flights under three different cabin temperatures were done in FTF and the various data were gathered during these flights. Air temperature in the cabin was measured on probes located near feet, torso and head of each passenger and also surface temperature and air temperature distributed from inlets were measured. The data were firstly analysed in order to obtain boundary conditions for cabin surfaces and inlets. Then the results of air temperature from the simulations were compared with measured data. The suitability and accuracy of the CFD approach for temperature prediction is discussed.

  7. 2013 German refrigeration and air conditioning meeting. Proceedings; Deutsche Kaelte- und Klimatagung 2013. Tagungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    These proceedings cover the following main topics: cryoengineering - superconduction / energy storage; cryoapplications in biology and medicine; metrology; adsorption processes; condensation/evaporation; working fluids / simulation; ice production; plants and compressors; expansion and ejectors or recooling; use of cooling (passenger car air conditioning, supermarket); refrigerants; plant efficiency; emissions and legislation; air conditioning and use of heat pumps; air quality and control; building technology and block-type thermal power stations. [German] Dieser Tagungsbericht enthaelt folgende Themenschwerpunkte: Kryotechnik - Supraleitung/Energiespeicher; Kryoanwendungen in der Biologie und Medizin; Messtechnik; Adsorptionsprozesse; Kondensation/Verdampfung; Arbeitsfluide/Simulation; Eiserzeugung; Anlagen und Verdichter; Expansion und Ejektoren bzw. Rueckkuehlung; Kaelteanwendung (PKW-Klimatisierung; Supermarkt); Kaeltemittel; Anlageneffizienz; Emissionen und Gesetzgebung; Klimatechnik und Waermepumpenanwendung; Luftqualitaet und Regelung; Gebaeudetechnik und BHKW.

  8. Solar energy contribution to the energy demand for air conditioning system in an office building under Tripoli climate conditions

    Directory of Open Access Journals (Sweden)

    Musbah Mohamed H.

    2014-01-01

    Full Text Available The feasibility of solar assisted air conditioning in an office building under Tripoli weather conditions is investigated in this paper. A single-effect lithium bromide absorption cycle powered by means of flat-plate solar collectors was modeled in order to predict the potential of the solar energy share. The cooling load profile was generated by using an detailed hourly based program and Typical meteorological year for Tripoli. System performance and solar energy fraction were calculated by varying two major parameters (collector’s slope angle and collector area. The maximum solar fraction of 48% was obtained by means of 1400 m2 of collector surface area. Analysis of results showed that, besides the collector surface area, the main factors affecting the solar fraction were the local weather conditions (intensity of incident solar radiation and the time of day when the plant was operated.

  9. Heat pump air conditioning system for pure electric vehicle at ultra-low temperature

    OpenAIRE

    Li Hai-Jun; Zhou Guang-Hui; Li An-Gui; Li Xu-Ge; Li Ya-Nan; Chen Jie

    2014-01-01

    When the ordinary heat pump air conditioning system of a pure electric vehicle runs at ultra-low temperature, the discharge temperature of compressor will be too high and the heating capacity of the system will decay seriously, it will lead to inactivity of the heating system. In order to solve this problem, a modification is put forward, and an experiment is also designed. The experimental results show that in the same conditions, this new heating system i...

  10. Respiratory learning and somatic complaints: A conditioning approach using CO2-enriched air inhalation

    OpenAIRE

    Van den Bergh, Omer; Kempynck, Pj; Van de Woestijne, K; Baeyens, Frank; Eelen, Paul

    1995-01-01

    In a differential respiratory conditioning paradigm with normal Ss two odors (fresh smelling niaouli and bad smelling ammonia) were used as conditioned stimuli (CS+ or CS-) and 7.4% CO2-enriched air was used as the unconditioned stimulus (US). Three CS+ and three CS- trials were run during acquisition, followed on the next day by the same number of CS+ and CS- only trials. Respiratory frequency, minute ventilation, end-tidal fractional concentration of CO2 and subjective complaints were measu...

  11. Simulation based energy consumption calculation of an office building using solar-assisted air conditioning

    OpenAIRE

    Thomas, Sébastien; Andre, Philippe

    2008-01-01

    To minimize environmental impact and CO2 production associated with air-conditioning system operation, it is reasonable to evaluate the prospects of a clean energy source. The targets of the study are to evaluate cooling energy consumption to maintain thermal comfort in an office building and to point out solar energy to satisfy these cooling needs. Simulations were carried out with three different cooling systems in the same operating conditions to determine as accurately as possible the pot...

  12. Evaluation of the AIRS and CrIS relative radiometric calibration under cloudy conditions

    Science.gov (United States)

    Aumann, Hartmut H.; Manning, Evan M.

    2014-09-01

    The validation of the radiometric calibration of virtually all infrared radiometers has previously been carried out under carefully selected, generally spatially uniform conditions, with the assumption that the radiometric accuracy of the data may be dependent on scene brightness temperature, but is independent of other scene unique conditions, such as scene spatial uniformity. The availability of AIRS and CrIS observations from polar orbits with the identical ascending node presents an opportunity to evaluate the validity of this assumption. For each day between May 2012 and January 2014 we collected 22,000 Random Nadir Spectra (RNS). We then analyzed the time series of the daily differences between AIRS and CrIS Probability Density Function in the 900 cm-1 atmospheric window channel. Under polar conditions the PDF differences between AIRS and CrIS are typically less than 50 mK for the 10%tile, the mean and the 90%tiles values of the PDF. Under area representative global conditions day and night CrIS is about 0.2K colder than AIRS at the 10%tile and mean values. These differences are well within the limits of the instrument requirements specification. However, the difference between AIRS and CrIS have a complicated zonal distribution, particular for the tropical zone. For day tropical land CrIS is 0.3 K warmer in the mean, 1K warmer in the 10%tile value (cold tails of the PDF) than AIRS. The reasons for these differences are still under investigation. A number of modifications to the CrIS radiometric calibration algorithms have been proposed.

  13. Research on performance of mixed absorption refrigeration for solar air-conditioning

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A novel lithium bromide/water mixed absorption refrigeration cycle that is suitable for the utilization of solar air-conditioning and can overcome the drawbacks of low system overall efficiency of traditional solar absorption refrigeration air-condition systems is presented.The accessorial high pressure generator was added in the cycle.The lithium bromide solution flowing out from the high pressure generator was mixed with the solution from the low pressure absorber to increase lithium bromide solution concentration and decrease pressure in the high pressure absorber.The performance of a mixed absorption refrigeration cycle was analyzed.The theoretical analysis shows that the highest COP is 0.61,while the highest available temperature difference of heat resource is 33.2℃.The whole coefficient of performance of the solar air-conditioning using mixed absorption cycle is 94.5% higher than that of two-stage absorption.The advantages of solar air-conditioning can be markedly made use of by the cycle.

  14. PIC (PRODUCTS OF INCOMPLETE COMBUSTION) FORMATION UNDER PYROLYTIC AND STARVED AIR CONDITIONS

    Science.gov (United States)

    A comprehensive program of laboratory studies based on the non-flame mode of thermal decomposition produced much data on PIC (Products of Incomplete Combustion) formation, primarily under pyrolytic and starved air conditions. Most significantly, laboratory results from non-flame ...

  15. Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air conditioning technology workshop

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    Sessions included: HFC blown polyurethanes, carbon dioxide blown foam and extruded polystyrenes, plastic foam insulations, evacuated panel insulation, refrigeration and air conditioning, absorption and adsorption and stirling cycle refrigeration, innovative cooling technologies, and natural refrigerants. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  16. Human requirements in future air-conditioned environments: a search for excellence

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from SBS symptoms, even though existing st...

  17. Application of Dual Throttling Air-Conditioning System to Explosion-Proof Frequency Converter

    Institute of Scientific and Technical Information of China (English)

    张于峰; 高岩; 盛颖

    2015-01-01

    An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inves-tigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning sys-tem was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrig-eration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experi-mental data.

  18. Off-gas and air cleaning systems for accident conditions in nuclear power plants

    International Nuclear Information System (INIS)

    This report surveys the design principles and strategies for mitigating the consequences of abnormal events in nuclear power plants by the use of air cleaning systems. Equipment intended for use in design basis accident and severe accident conditions is reviewed, with reference to designs used in IAEA Member States. 93 refs, 48 figs, 23 tabs

  19. Performance of residential air-conditioning systems with flow maldistribution in fin-and-tube evaporators

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Refrigerant and airflow maldistribution in fin-and-tube evaporators for residential air-conditioning was investigated with numerical modeling. Fin-and-tube heat exchangers usually have a pre-defined circuitry. However, the objective in this study was to perform a generic investigation of each...

  20. Human requirements in future air-conditioned environments: a search for excellence

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2000-01-01

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from SBS symptoms, even though existing...

  1. Geothermal as a heat sink application for raising air conditioning efficency

    Science.gov (United States)

    Ibrahim, Hesham Safwat Osman Mohamed

    2016-04-01

    Objective: Geothermal applications in heating, ventilation, air-conditioning is a US technology for more than 30 years old ,which saves more than 30% average energy cost than the traditional air-conditioning systems systems. Applying this technology in Middle East and African countries would be very feasible specially in Egypt specially as it suffers Electric crisis --The temperature of the condensers and the heat rejecting equipment is much higher than the Egyptian land at different depth which is a great advantages, and must be measured, recorded, and studied accurately -The Far goal of the proposal is to construct from soil analysis a temperature gradient map for Egypt and , African countries on different depth till 100 m which is still unclear nowadays and must be measured and recorded in databases through researches - The main model of the research is to study the heat transfer gradient through the ground earth borehole,grout,high density polyethylene pipes , and water inlet temperature which affect the electric efficiency of the ground source heat pump air conditioning unit Impact on the Region: Such research result will contribute widely in Energy saving sector specially the air conditioning sector in Egypt and the African countries which consumes more than 30% of the electric consumption of the total consumption . and encouraging Green systems such Geothermal to be applied

  2. Air-conditioning in the 21st century: impact on human productivity and energy consumption

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2000-01-01

    Although air-conditioning has played a positive role for economic development in warm climates, its image is globally mixed. Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from Sick Building Syndrome (SBS) symptoms...

  3. Refrigeration and Air Conditioning Mechanic: Apprenticeship Course Outline. Apprenticeship and Industry Training. 1411.2

    Science.gov (United States)

    Alberta Advanced Education and Technology, 2011

    2011-01-01

    The graduate of the Refrigeration and Air Conditioning Mechanic apprenticeship training is a journeyman who will: (1) supervise, train and coach apprentices; (2) use and maintain hand and power tools to the standards of competency and safety required in the trade; (3) have a thorough knowledge of the principle components of refrigeration systems,…

  4. Compensation of flow maldistribution in fin-and-tube evaporators for residential air-conditioning

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Brix, Wiebke; Elmegaard, Brian;

    2011-01-01

    Compensation of flow maldistribution in multi-channel fin-and-tube evaporators for residential air-conditioning is investigated by numerical modeling. The considered sources of maldistribution are distribution of the liquid and vapor phases in the distributor and non-uniform airflow distribution...

  5. Urban air quality assessment using monitoring data of fractionized aerosol samples, chemometrics and meteorological conditions.

    Science.gov (United States)

    Yotova, Galina I; Tsitouridou, Roxani; Tsakovski, Stefan L; Simeonov, Vasil D

    2016-06-01

    The present article deals with assessment of urban air by using monitoring data for 10 different aerosol fractions (0.015-16 μm) collected at a typical urban site in City of Thessaloniki, Greece. The data set was subject to multivariate statistical analysis (cluster analysis and principal components analysis) and, additionally, to HYSPLIT back trajectory modeling in order to assess in a better way the impact of the weather conditions on the pollution sources identified. A specific element of the study is the effort to clarify the role of outliers in the data set. The reason for the appearance of outliers is strongly related to the atmospheric condition on the particular sampling days leading to enhanced concentration of pollutants (secondary emissions, sea sprays, road and soil dust, combustion processes) especially for ultra fine and coarse particles. It is also shown that three major sources affect the urban air quality of the location studied-sea sprays, mineral dust and anthropogenic influences (agricultural activity, combustion processes, and industrial sources). The level of impact is related to certain extent to the aerosol fraction size. The assessment of the meteorological conditions leads to defining of four downwind patterns affecting the air quality (Pelagic, Western and Central Europe, Eastern and Northeastern Europe and Africa and Southern Europe). Thus, the present study offers a complete urban air assessment taking into account the weather conditions, pollution sources and aerosol fractioning. PMID:26942452

  6. Heating, Air Conditioning and Refrigeration. Vocational Education Curriculum Guide. Industrial and Technical Education.

    Science.gov (United States)

    West Virginia State Vocational Curriculum Lab., Cedar Lakes.

    This curriculum guide contains 17 units that provides the basic curriculum components required to develop lesson plans for the heating, air conditioning, and refrigeration curriculum. The guide is not intended to be a complete, self-contained curriculum, but instead provides the teacher with a number of informational items related to the learning…

  7. Instructional Guide for Air Conditioning and Refrigeration. V & TECC Curriculum Guide.

    Science.gov (United States)

    Duenk, Lester G.; And Others

    This trade and industrial curriculum guide is intended for use in vocational programs that prepare students to enter the air conditioning/refrigeration field. The introductory section provides a statement of philosophy, objectives, block time schedule, and recommended facilities and equipment. Following the introductory section, eighteen blocks of…

  8. Refrigeration and Air Conditioning Equipment, 11-9. Military Curriculum Materials for Vocational and Technical Education.

    Science.gov (United States)

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text consists of three blocks of instructional materials for use by those studying to become refrigeration and air conditioning specialists. Covered in the individual course blocks are the following topics: refrigeration and trouble analysis, thermodynamics, and principles of refrigeration; major components and domestic and…

  9. Non-Print Instructional Materials for the Air Conditioning and Refrigeration Maintenance Field.

    Science.gov (United States)

    Golitko, Raymond L., Ed.; And Others

    This catalog contains a listing of air conditioning/refrigeration maintenance audiovisual training materials from the Houston Community College System library media collection. The material is organized by subject heading. The media titles are listed in alphabetical order by title under each subject heading in the catalog. The citation for each…

  10. Impact of climate change on commercial sector air conditioning energy consumption in subtropical Hong Kong

    International Nuclear Information System (INIS)

    Past and future trend of electricity use for air conditioning in the entire commercial sector in subtropical climates using 1979-2008 measured meteorological data as well as predictions for 2009-2100 from a general circulation model (MIROC3.2-H) was investigated. Air conditioning consumption showed an increasing trend over the past 30 years from 1979 to 2008. Principal component analysis (PCA) of measured and predicted monthly mean dry-bulb temperature, wet-bulb temperature and global solar radiation was conducted to determine a new climatic index Z for 1979-2008 and future 92 years (2009-2100) based on two emissions scenarios B1 and A1B (low and medium forcing). Through regression analysis, electricity use in air conditioning for the 92-year period was estimated. For low forcing, average consumption in 2009-2038, 2039-2068 and 2069-2100 would be, respectively, 5.7%, 12.8% and 18.4% more than the 1979-2008 average, with a mean 12.5% increase for the entire 92-year period. Medium forcing showed a similar increasing trend, but 1-4% more. Standard deviations of the monthly air conditioning consumption were found to be smaller suggesting possible reduction in seasonal variations in future years.

  11. Performance and evaluation of gas engine driven rooftop air conditioning equipment at the Willow Grove (PA) Naval Air Station

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Conover, D.R.

    1993-05-01

    In a field evaluation conducted for the US Department of Energy (DOE) Office of Federal Energy Management Program (FEMP), the Pacific Northwest Laboratory (PNL) examined the performance of a new US energy-related technology under the FEMP Test Bed Demonstration Program. The technology was a 15-ton natural gas engine driven roof top air conditioning unit. Two such units were installed on a naval retail building to provide space conditioning to the building. Under the Test Bed Demonstration Program, private and public sector interests are focused to support the installation and evaluation of new US technologies in the federal sector. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) with DOE were the American Gas Cooling Center, Philadelphia Electric Company, Thermo King Corporation, and the US Naval Air Station at Willow Grove, Pennsylvania. Equipment operating and service data as well as building interior and exterior conditions were secured for the 1992 cooling season. Based on a computer assessment of the building using standard weather data, a comparison was made with the energy and operating costs associated with the previous space conditioning system. Based on performance during the 1992 cooling season and adjusted to a normal weather year, the technology will save the site $6,000/yr in purchased energy costs. An additional $9,000 in savings due to electricity demand ratchet charge reductions will also be realized. Detailed information on the technology, the installation, and the results of the technology test are provided to illustrate the advantages to the federal sector of using this technology. A history of the CRADA development process is also reported.

  12. Saving 50% of energy in air conditioning and refrigeration; 50% de ahorro de energia en aire acondicionado y refrigeracion

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez De la Fuente, Rodolfo Javier [Instituto para la Proteccion Ambiental de Nuevo Leon-CAINTRA, Nuevo Leon (Mexico); Bolado Tamez, Jaime Antonio [Industrias AlEn S. A. de C. V., Monterrey (Mexico)

    1998-12-31

    Due to the fact that the air conditioning systems represent up to 70% of the energy consumption in our buildings, to the constant raise of the electric tariffs and to the increment of temperatures in Nuevo Leon State, as well as the restrictions on the use of some refrigerant fluids because of its potential damage to the ozone layer (Montreal Protocol) and the preferential use of refrigerants with low global heating potential (Kioto Protocol). The Camara de la Industria de la Transformacion de Nuevo Leon (Nuevo Leon`s Transformation Industry Chamber) through the Instituto para la Proteccion Ambiental de Nuevo Leon (Nuevo Leon`s Institute for Environmental Protection), create the program ECO-REFRIGERATION whose three missions are: Increase the efficiency of air conditioning and refrigeration equipment, promote the substitution of refrigerants and extend the benefits of these projects to the community in general. [Espanol] Debido a que los sistemas de climatizacion representan hasta el 70% de consumo energetico en nuestros inmuebles, al constante incremento de las tarifas electricas, el incremento de las temperaturas en Nuevo Leon, asi como la restriccion del uso de algunos refrigerantes por su potencial de dano de la capa de ozono (Protocolo de Montreal) y el uso preferente de refrigerantes con bajo potencial de calentamiento global (Protocolo de Kioto), la Camara de la Industria de la Transformacion de Nuevo Leon a traves del Instituto para la Proteccion Ambiental de Nuevo Leon crean el Programa ECO-REFRIGERACION cuyas tres misiones son: Incrementar la eficiencia de los equipos de aire acondicionado y refrigeracion, promover la sustitucion de refrigerantes y extender los beneficios de este proyecto a la comunidad en general.

  13. Air-conditioning Australian households: The impact of dynamic peak pricing

    Energy Technology Data Exchange (ETDEWEB)

    Strengers, Yolande, E-mail: yolande.strengers@rmit.edu.a [Centre for Design, RMIT University, GPO Box 2476, Melbourne VIC 3001 (Australia)

    2010-11-15

    International mandates for smart metering are enabling variable and real-time pricing regimes such as dynamic peak pricing (DPP), which charges 10-40 times the off-peak rate for electricity during short periods. This regime aims to reduce peak electricity demand (predominantly due to increase in residential air-conditioning usage) and curb greenhouse gas emissions. Although trials indicate that DPP can achieve significant demand reductions, particularly in summer, little is known about how or why households change their cooling practices in response to this strategy. This paper discusses the outcomes of a small qualitative study assessing the impact of a DPP trial on household cooling practices in the Australian state of New South Wales. The study challenges common assumptions about the necessity of air-conditioning and impact of price signals. It finds that DPP engages households as co-managers of their cooling practices through a series of notification signals (SMS, phone, in-home display, email, etc.). Further, by linking the price signal to air-conditioning, some householders consider this practice discretionary for short periods of time. The paper concludes by warning that policy makers and utilities may serve to legitimise air-conditioning usage and/or negate demand reductions by failing to acknowledge the non-rational dynamics of DPP and household cooling practices. - Research highlights: {yields}Most householders consider air-conditioning discretionary during DPP events {yields}DPP engages householders as co-managers of their demand {yields}Notification of an upcoming DPP event is significant to the response {yields}Householders feel obligated to respond to DPP for a range of non-financial reasons

  14. Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems

    International Nuclear Information System (INIS)

    The performance of an air-conditioning unit with evaporately-cooled condenser coil is studied experimentally and numerically. An experimental setup is fabricated by retrofitting a commercially available air-conditioning unit and installing comprehensive measuring sensors and controllers. Experimental result shows that the COP (Coefficient of Performance) of the evaporately-cooled air-conditioning unit increases by about 28% compared to the conventional air cooled air-conditioning unit. To analyze the heat and mass transfer processes involved in the evaporately-cooled condenser, a detailed theoretical model has been developed based on the fluid flow characteristics of the falling film and the thermodynamic aspect of the evaporation process. Simulated results agree well with experimental data. The numerical model provides new insights into the intrinsic links between operating variables and heat transfer characteristics of water film in evaluating the performance of evaporatively-cooled condenser system. Two heat transfer coefficients, namely, wall to bulk and bulk to interface are introduced and computed from the simulation results under different operating conditions. Finally, the overall heat transfer coefficient for the water film is computed and presented as a function of dimensionless variables which can conveniently be employed by engineers to design and analyze high performance evaporatively-cooled heat exchangers. - Highlights: • Performance of evaporatively-cooled condenser is investigated. • Local convective heat transfer coefficients of water film are determined. • Thermal resistance of water film is negligible. • Heat transfer with evaporated vapor plays significant role on performance. • Better condenser performance translates to an improvement in COP

  15. Air-conditioning Australian households: The impact of dynamic peak pricing

    International Nuclear Information System (INIS)

    International mandates for smart metering are enabling variable and real-time pricing regimes such as dynamic peak pricing (DPP), which charges 10-40 times the off-peak rate for electricity during short periods. This regime aims to reduce peak electricity demand (predominantly due to increase in residential air-conditioning usage) and curb greenhouse gas emissions. Although trials indicate that DPP can achieve significant demand reductions, particularly in summer, little is known about how or why households change their cooling practices in response to this strategy. This paper discusses the outcomes of a small qualitative study assessing the impact of a DPP trial on household cooling practices in the Australian state of New South Wales. The study challenges common assumptions about the necessity of air-conditioning and impact of price signals. It finds that DPP engages households as co-managers of their cooling practices through a series of notification signals (SMS, phone, in-home display, email, etc.). Further, by linking the price signal to air-conditioning, some householders consider this practice discretionary for short periods of time. The paper concludes by warning that policy makers and utilities may serve to legitimise air-conditioning usage and/or negate demand reductions by failing to acknowledge the non-rational dynamics of DPP and household cooling practices. - Research highlights: →Most householders consider air-conditioning discretionary during DPP events →DPP engages householders as co-managers of their demand →Notification of an upcoming DPP event is significant to the response →Householders feel obligated to respond to DPP for a range of non-financial reasons

  16. Thermal comfort in air-conditioned mosques in the dry desert climate

    Energy Technology Data Exchange (ETDEWEB)

    Al-ajmi, Farraj F. [Department of Civil Engineering, College of Technological Studies, Shuwaikh 70654 (Kuwait)

    2010-11-15

    In Kuwait, as in most countries with a typical dry desert climate, the summer season is long with a mean daily maximum temperature of 45 C. Centralized air-conditioning, which is generally deployed from the beginning of April to the end of October, can have tremendous impact on the amount of electrical energy utilized to mechanically control the internal environment in mosque buildings. The indoor air temperature settings for all types of air-conditioned buildings and mosque buildings in particular, are often calculated based on the analytical model of ASHRAE 55-2004 and ISO 7730. However, a field study was conducted in six air-conditioned mosque buildings during the summers of 2007 to investigate indoor climate and prayers thermal comfort in state of Kuwait. The paper presents statistical data about the indoor environmental conditions in Kuwait mosque buildings, together with an analysis of prayer thermal comfort sensations for a total of 140 subjects providing 140 sets of physical measurements and subjective questionnaires were used to collect data. Results show that the neutral temperature (T{sub n}) of the prayers is found to be 26.1 C, while that for PMV is 23.3 C. Discrepancy of these values is in fact about 2.8 C higher than those predicted by PMV model. Therefore, thermal comfort temperature in Kuwait cannot directly correlate with ISO 7730 and ASHRAE 55-2004 standards. Findings from this study should be considered when designing air conditioning for mosque buildings. This knowledge can contribute towards the development of future energy-related design codes for Kuwait. (author)

  17. Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System

    Institute of Scientific and Technical Information of China (English)

    WANG Jiangjiang; AN Dawei; ZHANG Chunfa; JING Youyin

    2009-01-01

    Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multi-variable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified l0 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control.

  18. Air-lift pumps characteristics under two-phase flow conditions

    International Nuclear Information System (INIS)

    Air-lift pumps are finding increasing use where pump reliability and low maintenance are required, where corrosive, abrasive, or radioactive fluids in nuclear applications must be handled and when a compressed air is readily available as a source of a renewable energy for water pumping applications. The objective of the present study is to evaluate the performance of a pump under predetermined operating conditions and to optimize the related parameters. For this purpose, an air-lift pump was designed and tested. Experiments were performed for nine submergence ratios, and three risers of different lengths with different air injection pressures. Moreover, the pump was tested under different two-phase flow patterns. A theoretical model is proposed in this study taking into account the flow patterns at the best efficiency range where the pump is operated. The present results showed that the pump capacity and efficiency are functions of the air mass flow rate, submergence ratio, and riser pipe length. The best efficiency range of the air-lift pumps operation was found to be in the slug and slug-churn flow regimes. The proposed model has been compared with experimental data and the most cited models available. The proposed model is in good agreement with experimental results and found to predict the liquid volumetric flux for different flow patterns including bubbly, slug and churn flow patterns

  19. Open absorption system for cooling and air conditioning using membrane contactors - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Conde-Petit, M. [M. Conde Engineering, Zuerich (Switzerland); Weber, R.; Dorer, V. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland)

    2008-07-01

    Air conditioning systems based upon the open absorption principle, essentially an absorption device operating at atmospheric pressure, have been proposed and investigated at many instances in the past eighty years. Their potential for improving energy efficiency is clearly recognized in the earliest research reports. By the mid 1950ies, solar thermal energy was being applied to drive open absorption-based air conditioning systems. For several reasons, however, the open absorption technology was not mature enough to take place in the mainstream. In the past two decades, vigorous efforts have been undertaken to reverse this situation, but success continued to elude, despite the fact that the main problems, such as corrosion, aerosols in the supply air, etc., have been identified. This report details the work and the main results from the MemProDEC Project. In this project innovative solutions were proposed, and successfully investigated, for the corrosion problem and the improvement of efficiency of the absorption process, in particular a new method to cool a very compact absorber. The practically uniform flow distribution for all three streams in the absorber (air, water and desiccant) warrants the contact of the air to be dehumidified with the desiccant over the whole surface of exchange (across a porous membrane). This, together with the cooling with water in counter flow to the air, are the key factors for the excellent effectiveness of the absorber. As the results show, the dehydration effectiveness of the prototype absorber is up to 150 % higher than that previously obtained by others. The solutions developed for compactness and modularity represent an important step in the way to flexible manufacturing, i.e. using a single element size to assemble autonomous air handling units of various nominal capacities. And although the manufacturing methods of the individual elements require improvement, namely by avoiding adhesive bonding, the choice of materials and the

  20. Dust deposition in ventilation and air-conditioning duct bend flows

    International Nuclear Information System (INIS)

    Highlights: ► We study particle deposition on the four inner surface of the duct bend. ► We analyse the effect of five ways of placements of the bend on particle deposition. ► Gravity and inertia force enhance the deposition as relaxation time rises. ► Deposition coefficient increases as air velocity or particle diameter increases. - Abstract: Particles carried by airflows in ventilation and air-conditioning systems have adverse effects on the quality of air in buildings and hence the health of building occupants. Gaining insight on particle deposition onto ventilation and air-conditioning duct bends is important for controlling pollutant dispersion. Based on the Reynolds stress transport model (RSM), this paper has taken into account the effects of drag, lift force, gravity, inertia force, turbulent diffusions, particle size and air velocity on the dimensionless deposition velocity of particles in smooth duct bends using fully developed velocity profiles. At two different air velocities of 3.0 m/s and 7.0 m/s, the aforementioned effects were predicted by Reynolds-averaged Navier–Stokes (RANS)-Lagrangian simulation on square shaped duct bends with different ways of placement. Preliminary results suggest that gravity and inertia force enhance the dimensionless deposition as dimensionless relaxation time rises. Change tendency of the dimensionless particle deposition velocity on different surfaces of bend duct agrees well with previous studies. As air velocity and particle diameter increase, a significant increase of particle deposition coefficient in the duct bends is observed. Particle deposition to intrados can be intensified by the combined action of gravity and inertia force in different direction.

  1. Research on frequency conversion technology of metro station's ventilation and air-conditioning system

    International Nuclear Information System (INIS)

    Ventilation and air-conditioning system (VAC) is the most energy-saving potential system in the metro. This paper analyzes the passenger traffic, air-conditioning load and station air supply on the initial, recent and long-term phase of metro station. And it proposes that it is necessary to run chilled-water pumps, air handing unit (AHU) fans and back/exhaust fans with frequency conversion technology (FCT). Then it uses the thermodynamic method to analyze the impact of running chilled-water pumps with FCT. The results show that running chilled-water pumps with FCT can reduce the total power consumption of system, although increases chiller energy consumption. Then the temperature and velocity fields of the platform and station hall are simulated by CFD software according to the variable air volume. And the results show that under the condition of running the VAC system with FCT, temperature and velocity fields distribution are both in the comfortable range. Finally, by taking a typical summer day for example, this paper analyzes the energy savings of chilled-water pumps, AHU fans and back/exhaust fans on the initial, recent and long-term phase, and the calculation results show that the respective total energy savings are 1103.4 kWh, 1064.3 kWh and 926.2 kWh, and the respective total power saving ratio is 73.4%, 71.2% and 59.5%. - Highlights: •Use the FCT to reduce energy consumption of metro VAC is necessary and possible. •Analyze the influence of running the chilled-water pumps with FCT. •Results show that variable air volume of station public area is feasible. •Calculations indicate that energy-saving effect of using the FCT is considerable

  2. New principle of organization of working process of air conditioning systems at railway and sea transport

    Directory of Open Access Journals (Sweden)

    Andrey KRAJNIUK

    2008-01-01

    Full Text Available An indispensable component of ensuring safe control of railway and sea transport in conditions of hot climate is maintenance of comfortable temperature of air in control cabins and living spaces. Now the interest is restored to use the Air Refrigerating Plants (ARP as they have a wide potential of low-temperature cooling without use of ozone-destructive cooling agents prohibited by decision of the Montreal meeting. At the same time, air conditioning installations on the basis of turbo-expanders have low refrigerating factor, they are very expensive in manufacturing and require a high level of maintenance service.Alternative trend of perfection of air refrigeration units is connected with a new principle of organization of working process, based on the use as expander and compressor of aggregates of cascade exchanger of pressure (CPE. Besides of unsurpassed efficiency of exchange processes, CPE is characterized by simplicity of design and high reliability, including, due to low frequency of rotation (2000-3000 min-1 with practically absence of consumption of mechanical energy on the drive of the rotor. The attractive aspect of application of equipment of conditioning with CPE is the opportunity of organization of working process only due to thermal energy including the utilization in the heat-power installation of transport vehicle.

  3. Solar Absorption Refrigeration System for Air-Conditioning of a Classroom Building in Northern India

    Science.gov (United States)

    Agrawal, Tanmay; Varun; Kumar, Anoop

    2015-10-01

    Air-conditioning is a basic tool to provide human thermal comfort in a building space. The primary aim of the present work is to design an air-conditioning system based on vapour absorption cycle that utilizes a renewable energy source for its operation. The building under consideration is a classroom of dimensions 18.5 m × 13 m × 4.5 m located in Hamirpur district of Himachal Pradesh in India. For this purpose, cooling load of the building was calculated first by using cooling load temperature difference method to estimate cooling capacity of the air-conditioning system. Coefficient of performance of the refrigeration system was computed for various values of strong and weak solution concentration. In this work, a solar collector is also designed to provide required amount of heat energy by the absorption system. This heat energy is taken from solar energy which makes this system eco-friendly and sustainable. A computer program was written in MATLAB to calculate the design parameters. Results were obtained for various values of solution concentrations throughout the year. Cost analysis has also been carried out to compare absorption refrigeration system with conventional vapour compression cycle based air-conditioners.

  4. Design guides for solar assisted air conditioning; Auslegungshinweise fuer die Solargestuetzte Klimatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Franzke, U.; Seifert, C. [Institut fuer Luft- und Kaeltetechnik gGmbH, Dresden (Germany)

    2005-10-01

    The design of solar assisted air conditioning systems required a detailed consideration of the whole system, which consist of the building, the use, the air handling unit and the solar energy production. The decision about the application of solar energy is necessary in an earlier phase of the design process of the building. But at this moment, the necessary information are not available. With help of the simulation tool SOLAC it's possible to define an optimised system on a low level of information input. (orig.)

  5. Talaromyces rubrifaciens, a new species discovered from heating, ventilation and air conditioning systems in China.

    Science.gov (United States)

    Luo, Yi; Lu, Xiaohong; Bi, Wu; Liu, Fan; Gao, Weiwei

    2016-01-01

    A new Talaromyces species, T. rubrifaciens, was isolated from supply air outlets of heating, ventilation and air conditioning (HVAC) systems in three kinds of public building in Beijing and Nanjing, China. Morphologically it exhibits many characters of section Trachyspermi but is distinguished from other species of this section by restricted growth and broad and strictly biverticillate conidiophores. Phylogenetic analyses based on the internal transcribed spacer rDNA (ITS), β-tubulin (BenA), calmodulin (CaM) and RNA polymerase second largest subunit (RPB2) genes reveal that T. rubrifaciens is a distinct species in section Trachyspermi. PMID:27055570

  6. The effects of ambient conditions on the calibration of air flow plate standards

    Directory of Open Access Journals (Sweden)

    Miao Qian

    2013-01-01

    Full Text Available The volume flow rate measured by air flow plate is influenced by the ambient conditions during the calibration. A series of numerical examples are conducted for the relationship and the outcomes demonstrated that the calibration is quite sensitive to the atmospheric pressure and the ambient temperature, but insensitive to relative humidity. The experiment model has been applied to calibration results with wide ranging ambient conditions. In conclusion, the results of this study demonstrate the benefits to calibration data of minimizing the effects of ambient conditions.

  7. Development and analysis of an economizer control strategy algorithm to promote an opportunity for energy savings in air conditioning installations

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M.; Azevedo, Walter L. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefetmg.br

    2000-07-01

    This work presents an algorithm control strategy denominated enthalpy economizer. The objective of this algorithm strategy is to determine the adequate fractions of outside and return air flowrates entering a cooling coil based on the analysis of the outside, return and supply air enthalpies, rather than on the analysis of the dry bulb temperatures. The proposed algorithm predicts the actual opening position of the outside and return air dampers in order to provide the lower mixing air enthalpy. First, the psychometrics properties of the outside and return air are calculated from actual measurements of the dry and wet bulb temperatures. Then, three distinct cases are analyzed: the enthalpy of the outside air is lower than the enthalpy of the supply air (free cooling); the enthalpy of the outside air is higher than the enthalpy of the return air; the enthalpy of the outside air is lower than the enthalpy of the return air and higher than the temperature of the supply air. Different outside air conditions were selected in order to represent typical weather data of Brazilians cities, as well as typical return air conditions. It was found that the enthalpy control strategy could promote an opportunity for energy savings mainly during mild nights and wintertime periods as well as during warm afternoons and summertime periods, depending on the outside air relative humidity. The proposed algorithm works well and can be integrated in some commercial automation software to reduce energy consumption and electricity demand. (author)

  8. Air Pollution modifies the association between successful and pathological aging throughout the frailty condition.

    Science.gov (United States)

    Fougère, Bertrand; Vellas, Bruno; Billet, Sylvain; Martin, Perrine J; Gallucci, Maurizio; Cesari, Matteo

    2015-11-01

    The rapid growth in the number of older adults has many implications for public health, including the need to better understand the risks posed by environmental exposures. Aging leads to a decline and deterioration of functional properties at the cellular, tissue and organ level. This loss of functional properties yields to a loss of homeostasis and decreased adaptability to internal and external stress. Frailty is a geriatric syndrome characterized by weakness, weight loss, and low activity that is associated with adverse health outcomes. Frailty manifests as an age-related, biological vulnerability to stressors and decreased physiological reserves. Ambient air pollution exposure affects human health, and elderly people appear to be particularly susceptible to its adverse effects. The aim of this paper is to discuss the role of air pollution in the modulation of several biological mechanisms involved in aging. Evidence is presented on how air pollution can modify the bidirectional association between successful and pathological aging throughout the frailty conditions. PMID:26462883

  9. The effects of outdoor air supply rate and supply air filter condition in classrooms on the performance of schoolwork by children (RP-1257)

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David Peter

    2007-01-01

    Two independent field intervention experiments were carried out in mechanically ventilated classrooms receiving 100% outdoor air. Outdoor air supply rate and filter condition were manipulated to modify indoor air quality, and the performance of schoolwork was measured The conditions were establis......Two independent field intervention experiments were carried out in mechanically ventilated classrooms receiving 100% outdoor air. Outdoor air supply rate and filter condition were manipulated to modify indoor air quality, and the performance of schoolwork was measured The conditions were...... scales to indicate their environmental perceptions and the intensity of any symptoms. The children indicated that the air was fresher but otherwise perceived little difference when the outdoor air supply rate increased from 3.0 to 8.5 L/s (6.4-18 cfm) per person, while the speed at which they performed...... classrooms as judged by a sensory panel of adults blind to conditions, as perceived by children, and as indicated by the reduction in the average CO2 concentration from 1300 to 900 ppm, taking this as a marker of reduced bioeffluent concentration. It was not possible to test the effect of replacing a soiled...

  10. Development of Temperature-Humidity Independent Control Air-Conditioning Unit for Residential Buildings

    Institute of Scientific and Technical Information of China (English)

    HAN Xing; ZHANG Xu; LIU Jin-tao; GA Si-yun; KANG yue

    2009-01-01

    Cooling panels are increasingly used in domestic residential buildings.To provide medium temper-ature cold water for the cooling panel,and dehumidify the indoor air simultaneously,a new kind of temperature-humidity independent control air-conditioning unit was developed for single residential house by utilizing multi-variable technology.First,the supply air temperature was studied to determine the proper supply air flow rate for the humidity control.Then,the energy consumption of different temperature-humidity independent eontrol systems was studied.The analysis indicates that unity evaporating temperature can be used to handle the mois-ture load and sensible heat load in two evaporators.So the unit scheme was put forward.Two evaporators were used to produce medium temperature water and dry air separately,and electric expansion valves were used to control the refrigerant distribution between the two evaporators.Then, experimental work was carried out to in-vestigate the influence of compressor frequency,refrigerant distribution on the dehumidification capacity,energy efficiency and refrigeration capacity.In the end,the paper concludes that both compressor frequency and refrig-erant distribution can control the dehumidification capacity,but the former influences the EER more than the latter.while the latter influences the refrigeration capacity more than the former.We can find a proper running point at certain sensible and latent cooling load by adjusting both compressor frequency and electric expansion.valve.The energy consumption of this kind of unit was estimated and compared with present room air condition-ers,which shows that it can save about 41% cooling energy consumption.

  11. Children's well-being at schools: Impact of climatic conditions and air pollution.

    Science.gov (United States)

    Salthammer, Tunga; Uhde, Erik; Schripp, Tobias; Schieweck, Alexandra; Morawska, Lidia; Mazaheri, Mandana; Clifford, Sam; He, Congrong; Buonanno, Giorgio; Querol, Xavier; Viana, Mar; Kumar, Prashant

    2016-09-01

    Human civilization is currently facing two particular challenges: population growth with a strong trend towards urbanization and climate change. The latter is now no longer seriously questioned. The primary concern is to limit anthropogenic climate change and to adapt our societies to its effects. Schools are a key part of the structure of our societies. If future generations are to take control of the manifold global problems, we have to offer our children the best possible infrastructure for their education: not only in terms of the didactic concepts, but also with regard to the climatic conditions in the school environment. Between the ages of 6 and 19, children spend up to 8h a day in classrooms. The conditions are, however, often inacceptable and regardless of the geographic situation, all the current studies report similar problems: classrooms being too small for the high number of school children, poor ventilation concepts, considerable outdoor air pollution and strong sources of indoor air pollution. There have been discussions about a beneficial and healthy air quality in classrooms for many years now and in recent years extensive studies have been carried out worldwide. The problems have been clearly outlined on a scientific level and there are prudent and feasible concepts to improve the situation. The growing number of publications also highlights the importance of this subject. High carbon dioxide concentrations in classrooms, which indicate poor ventilation conditions, and the increasing particle matter in urban outdoor air have, in particular, been identified as primary causes of poor indoor air quality in schools. Despite this, the conditions in most schools continue to be in need of improvement. There are many reasons for this. In some cases, the local administrative bodies do not have the budgets required to address such concerns, in other cases regulations and laws stand in contradiction to the demands for better indoor air quality, and sometimes

  12. Heat recovery in air conditioning systems in frost-free season with using adiabatic cooling. Capacities overview

    Directory of Open Access Journals (Sweden)

    S.V. Chuduk

    2011-01-01

    Full Text Available In article the review of the information on possibilities of use of recuperators of heat is presented for the warm period of year for air-conditioning system. Aim of heat exchanger work in frost-free season is indirect cooling of incoming air before its input into maintainable premises. It is possible if exhaust air is cooled before its input into heat exchanger . In the article the operational principle of air conditioning system with using of adiabatic air cooling is considered. The data concerned system functioning depending on parameters of microclimate in maintainable premises are given.

  13. Radon mitigation in schools utilising heating, ventilating and air conditioning systems

    International Nuclear Information System (INIS)

    As part of a continuing radon in schools technology development effort, EPA's School Evaluation Team has performed radon mitigation in schools by the method of ventilation/pressurisation control technology. Ventilation rates were increased, at a minimum, to meet the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) standard, Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1989). This paper presents the results and the preliminary evaluations which led to the team's decision to implement this technology. Factors considered include energy penalties, comfort, indoor air quality (IAQ), building shell tightness, and equipment costs. Cost benefit of heat recovery ventilation was also considered. Earlier results of the SEP team's efforts have indicated a severe ventilation problem within the schools of the United States. Two case studies are presented where HVAC technology was implemented for controlling radon concentrations. One involved the installation of a heat recovery ventilator to depressurise a crawl space and provide ventilation to the classrooms which previously had no mechanical ventilation. The other involved the restoration of a variable air volume system in a two-storey building. The HVAC system's controls were restored and modified to provide a constant building pressure differential to control the entry of radon. Pre-mitigation and post-mitigation indoor air pollutant measurements were taken, including radon, carbon dioxide (CO2), particulates, and bio-aerosols. Long-term monitoring of radon, CO2, building pressure differentials, and indoor/outdoor temperature and relative humidity is presented. (author)

  14. Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.; Lowenstein, A.

    2014-09-01

    Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

  15. Acoustics of motor car air conditioning systems; Akustik der Kfz-Klimaanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Matthes, M.; Martini, J.; Cucuz, S. [Visteon Deutschland GmbH, VTZ Kerpen (Germany)

    2002-07-01

    Air conditioning systems in motor cars provide thermal comfort but the noise level may increase to an extent that makes the driver shut off the air conditioning system altogether. The contribution presents an introduction to acoustics. The human ear is described, and typical acoustic parameters like sound pressure, sound intensity, acoustic power and level definitions are introduced. Measuring systems and techniques are described, and typical problems and solutions in air conditioner acoustics are gone into. Finally, empirical estimates are made for the sound pressure level of ventilation nozzles and air conditioners. [German] Gestiegene Komfortansprueche der Kfz-Insassen haben in Europa waehrend der letzten Dekade die Kfz-Klimaanlage zu einem Standard-Ausstattungsmerkmal in der oberen Mittelklasse werden lassen, und auch kleinere Fahrzeugklassen (B- und C-Segment) folgen dieser Entwicklung auf dem Fusse. Die Hauptaufgabe der Kfz-Klimaanlage - die Bereitstellung des thermischen Komforts - wird aber mit akustischen Belastungen der Fahrzeuginsassen erkauft. Die akustische Belastung kann dabei so gross werden, dass die Insassen von einem optimalen Gebrauch der Klimaanlage absehen - einfach weil sie zu laut ist. Um einen moeglichst umfassenden Einblick in die Akustik zu gewaehren, wird zunaechst das menschliche Gehoer vorgestellt. Danach werden typische Kenngroessen der Akustik wie Schalldruck, Schallintensitaet und Schallleistung und die entsprechenden Pegeldefinitionen eingefuehrt. Im zweiten Abschnitt werden Messraeume und Messverfahren vorgestellt, um dann auf typische Probleme und Loesungsmoeglichkeiten in der Klimageraeteakustik einzugehen. Schliesslich werden empirische Abschaetzungen fuer den Schalldruckpegel von Belueftungsduesen und Klimageraeten vorgestellt. (orig.)

  16. Effect of green roofs on air temperature; measurement study of well-watered and dry conditions

    Science.gov (United States)

    Solcerova, Anna; van de Ven, Frans; Wang, Mengyu; van de Giesen, Nick

    2016-04-01

    Rapid urbanization and increasing number and duration of heat waves poses a need for understanding urban climate and ways to mitigate extremely high temperatures. One of repeatedly suggested and often investigated methods to moderate the so called urban heat island are green roofs. This study investigates several extensive green roofs in Utrecht (NL) and their effect on air temperature right above the roof surface. Air temperature was measured 15 and 30 cm above the roof surface and also in the substrate. We show that under normal condition is air above green roof, compared to white gravel roof, colder at night and warmer during day. This suggest that green roofs might help decrease air temperatures at night, when the urban heat island is strongest, but possibly contribute to high temperatures during daytime. We also measured situation when the green roofs wilted and dried out. Under such conditions green roof exhibits more similar behavior to conventional white gravel roof. Interestingly, pattern of soil temperature remains almost the same for both dry and well-prospering green roof, colder during day and warmer at night. As such, green roof works as a buffer of diurnal temperature changes.

  17. Impact of summer office set air-conditioning temperature on energy consumption and thermal comfort

    Institute of Scientific and Technical Information of China (English)

    刘红; 马小磊; 高亚峰

    2009-01-01

    To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.

  18. Containment vessel, its auxiliary system and plant air conditioning system of advanced thermal reactor Fugen

    International Nuclear Information System (INIS)

    The functional requirement for, the design and the construction of, and the functional test on the containment vessel, its auxiliary system, the plant air conditioning and ventilation system of the advanced thermal reactor, Fugen, are described in detail. The main specifications of the containment vessel are as follows: The type enclosed cylinder, the maximum operating pressure 1.35 kg/cm2g, the maximum operating temperature 100 deg C, the leak rate 0.4%/day, the inner diameter 36 m. The height 64 m, the volume 40,900 m3, and the material JIS G3118, SGV-49. The containment vessel is provided with an hatch of 5 m diameter for carrying equipments in two air locks, many high and low voltage cable penetrations, pipe penetrations, a transfer shoot and isolation values. The functions and the specifications of the containment vessel and its auxiliary equipments are explained. The relating auxiliary systems are composed of the containment vessel spray system, the pool facility for steam blow-down, the recirculation system for the air in the vessel, the annulus evacuation system and its pressure control devices, the pressure measuring instruments and pressure relief valves and the temperature measuring devices for the containment vessel, and the object, function, layout and installation of these systems are explained. Concerning the air conditioning system, each main building has the special subsystem, and they are introduced. The progress stage of construction works and the procedure and results of the functional test at the site are described. (Nakai, Y.)

  19. Modeling solar-driven ejector refrigeration system offering air conditioning for office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Guo, J.; Shen, H.G. [School of Environmental Science and Engineering, Donghua University, 2999 North Renmin Road, Shanghai 201620 (China)

    2009-02-15

    A lumped method combined with dynamic model is proposed for use in investigating the performance and solar fraction of a solar-driven ejector refrigeration system (SERS) using R134a, for office air conditioning application for buildings in Shanghai, China. Classical hourly outdoor temperature and solar radiation model were used to provide basic data for accurate analysis of the system performance. Results indicate that during the office working-time, i.e., from 9:00 to 17:00, the average COP and the average solar fraction of the system were 0.48 and 0.82 respectively when the operating conditions were: generator temperature (85 C), evaporator temperature (8 C) and condenser temperature varying with ambient temperature. Compared with traditional compressor based air conditioner, the system can save upto 80% electric energy when providing the same cooling capacity for office buildings. Hence, the system offers a good energy conservation method for office buildings. (author)

  20. Optimization of Selecting Air Conditioning Cold/Heat Sources with Grey Relation Analysis

    Institute of Scientific and Technical Information of China (English)

    CAO Guoqing; TU Guangbei

    2006-01-01

    Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems.Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information.It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management.Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible.Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sources.

  1. Private air conditioning systems - just a matter of conscience?; Ist eine private Klimaanlage nur eine Gewissensfrage?

    Energy Technology Data Exchange (ETDEWEB)

    Rogg, W. [NOK-Energieanwendung, Baden (Switzerland)

    1996-08-01

    Until recently, air conditioning systems in private buildings and single office rooms were an exception in this country rather than the rule, but it seems that the hot summer of 1995 brought about a change in this field. Confronted with the choice of raising their energy consumption and having to face the extreme heat, many house owners decided to install an air conditioning system. (orig.) [Deutsch] Bis vor kurzem bildeten Raumkuehlgeraete in Privathaushalten und Einzelbueros hierzulande eher die Ausnahme. Dies scheint seit dem letzten Sommer der Vergangenheit anzugehoeren, will man den Verkaufszahlen des Handels Glauben schenken. Im Gewissenskonflikt zwischen Energiesparen und Hitzekollaps moegen sich so manche schweissgeplagten Mitbuerger beim Kauf eines solchen Geraets in thermischer Notwehr befunden haben. (orig.)

  2. Ant-nest corrosion of copper tubing in air-conditioning units

    International Nuclear Information System (INIS)

    Ant-nest corrosion is a specific type of premature failure (2-3 months) of copper tubes used in air-conditioning units causing the loss of refrigerant liquid and the consequent environment pollution. It is known that attack requires the simultaneous presence of moisture, oxygen and a corrodent, usually an organic acid, such as formic, acetic propionic or butyric acid or other volatile organic substances like methanol, ethanol, formaldehyde or aceto aldehyde. Approximately 10% of all premature failures of copper tubes used in the heating, ventilation and air-conditioning (HVAC) industry are the results of ant-nest corrosion. This type of corrosion usually occurs in thin-wall copper pipes, especially when copper is de-sulphurised, and is known by several names: formicary corrosion, unusual corrosion, branched pits,pinhole corrosion, etc. (Author) 91 refs

  3. Characterization of Francisella species isolated from the cooling water of an air conditioning system.

    Science.gov (United States)

    Gu, Quan; Li, Xunde; Qu, Pinghua; Hou, Shuiping; Li, Juntao; Atwill, Edward R; Chen, Shouyi

    2015-01-01

    Strains of Francisella spp. were isolated from cooling water from an air conditioning system in Guangzhou, China. These strains are Gram negative, coccobacilli, non-motile, oxidase negative, catalase negative, esterase and lipid esterase positive. In addition, these bacteria grow on cysteine-supplemented media at 20 °C to 40 °C with an optimal growth temperature of 30 °C. Analysis of 16S rRNA gene sequences revealed that these strains belong to the genus Francisella. Biochemical tests and phylogenetic and BLAST analyses of 16S rRNA, rpoB and sdhA genes indicated that one strain was very similar to Francisella philomiragia and that the other strains were identical or highly similar to the Francisella guangzhouensis sp. nov. strain 08HL01032 we previously described. Biochemical and molecular characteristics of these strains demonstrated that multiple Francisella species exist in air conditioning systems. PMID:26413079

  4. Modeling of an Air Conditioning System with Geothermal Heat Pump for a Residential Building

    Directory of Open Access Journals (Sweden)

    Silvia Cocchi

    2013-01-01

    Full Text Available The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling, through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.

  5. Decoupling dehumidification and cooling for energy saving and desirable space air conditions in hot and humid Hong Kong

    International Nuclear Information System (INIS)

    Highlights: ► The combined use of dedicated ventilation and dry cooling (DCDV) system was investigated. ► Investigations were based actual equipment performance data and realistic building and system characteristics. ► DCDV system could save 54% of the annual energy use for air-conditioning. ► DCDV system could better achieve the desired space air conditions. ► DCDV system could decouple dehumidification and cooling. - Abstract: The combined use of dedicated outdoor air ventilation (DV) and dry cooling (DC) air-conditioning system to decouple sensible and latent cooling for desirable space air conditions, better indoor air quality, and energy efficiency is proposed for hot and humid climates like Hong Kong. In this study, the performance and energy saving potential of DCDV system in comparison to conventional systems (constant air volume (CAV) system with and without reheat) for air conditioning of a typical office building in Hong Kong are evaluated. Through hour-by-hour simulations, using actual equipment performance data and realistic building and system characteristics, the cooling load profile, resultant indoor air conditions, condensation at the DC coil, and energy consumptions are calculated and analyzed. The results indicate that with the use of DCDV system, the desirable indoor conditions could be achieved and the annual energy use could be reduced by 54% over CAV system with reheat. The condensate-free characteristic at the DC coil to reduce risk of catching disease could also be realized.

  6. Sustainability Challenges from Climate Change and Air Conditioning Use in Urban Areas

    OpenAIRE

    Karin Lundgren; Tord Kjellstrom

    2013-01-01

    Global climate change increases heat loads in urban areas causing health and productivity risks for millions of people. Inhabitants in tropical and subtropical urban areas are at especial risk due to high population density, already high temperatures, and temperature increases due to climate change. Air conditioning is growing rapidly, especially in South and South-East Asia due to income growth and the need to protect from high heat exposures. Studies have linked increased total hourly elect...

  7. Review on Conventional Air Conditioning, Alternative Refrigerants, and CO2 Heat Pumps for Vehicles

    OpenAIRE

    Moo-Yeon Lee; Dong-Yeon Lee

    2013-01-01

    With the reinforced ODP and GWP regulations, clean refrigerants including CO2, energy saving technology for fuel economy, especially focused on development and control strategy for the effective air conditioning system, and heat pump for vehicles have been widely investigated. Recently, the automotive CO2 heat pump for the next generation vehicles as an alternative to that of internal combustion engines has been evaluated and studied as a good option. In this paper, first part is reviewed on ...

  8. Performance Evaluation of an Air-Conditioning Compressor Part I: Measurement and Design Modeling

    OpenAIRE

    Thomas W. Bein; Yu-Tai Lee

    1999-01-01

    In order to comply with legislation to eliminate the use of refrigerants that damage the ozone layer, it is necessary to redesign centrifugal compressors, used by the US Navy for shipboard air-conditioning systems, to use an environmentally acceptable refrigerant. This paper describes an evaluation of a 125-ton compressor designed to use HCFC-124 as the refrigerant. The objectives are not only conducting the performance evaluation, but also pinpointing the design problems for achieving a high...

  9. R32 Compressor for Air conditioning and Refrigeration applications in China

    OpenAIRE

    Guo, Weihua; Ji, GaoFeng; Zhan, Honghong; Wang, Dan

    2012-01-01

    This paper evaluates the compressor performance and reliability impact by using R32 refrigerant for air conditioning (residential and commercial system); Performance and reliability impacts are compared with different popular refrigerants used in China, for example, R410A & R22 for AC. The design improvement on the scroll compressor will be discussed in order to reach required efficiency and reliability; these improvements include lubrication, internal heat management, motor design, and vapor...

  10. Using Vibration Analysis to Determine Refrigerant Levels In an Automotive Air Conditioning System

    OpenAIRE

    Stasiunas, Eric Carl

    2002-01-01

    Presently, auto manufacturers do not have do not have efficient or accurate methods to determine the amount of refrigerant (R-134a) in an air conditioning system of an automobile. In the research presented, vibration analysis is examined as a possible method to determine this R-134a amount. Initial laboratory tests were completed and experimental modal analysis methods were investigated. This approach is based on the hypothesis that the natural frequency of the accumulator bott...

  11. Performance Evaluation of an Air-Conditioning Compressor Part II: Volute Flow Predictions

    OpenAIRE

    Yu-Tai Lee; Thomas W. Bein

    1999-01-01

    A numerical method that solves the Reynolds-averaged Navier-Stokes equations is used to study an inefficient component of a shipboard air-conditioning HCFC-124 compressor system. This high-loss component of the centrifugal compressor was identified as the volute through a series of measurements given in Part I of the paper. The predictions were made using three grid topologies. The first grid closes the connection between the cutwater and the discharge diffuser. The other two grids connect th...

  12. A novel air-conditioning system for proactive power demand response to smart grid

    International Nuclear Information System (INIS)

    Highlights: • A novel air-conditioning system with proactive demand response is proposed. • The system can significantly reduce the storage volume of the chilled water tank. • Demand side bidding and demand as frequency controlled reserve can be implemented. • No impact on occupants when demand response is used in the proposed system. - Abstract: Power demand response is considered as one of the most promising solutions in relieving the power imbalance of an electrical grid that results a series of critical problems to the gird and end-users. In order to effectively make use of the demand response potentials of buildings, this paper presents a novel air-conditioning system with proactive demand control for daily load shifting and real time power balance in the developing smart grid. This system consists of a chilled water storage system (CWS) and a temperature and humidity independent control (THIC) air-conditioning system, which can significantly reduce the storage volume of the chilled water tank and effectively enable a building with more flexibility in changing its electricity usage patterns. The power demand of the proposed air-conditioning system can be flexibly controlled as desired by implementing two types of demand response strategies: demand side bidding (DSB) strategy and demand as frequency controlled reserve (DFR) strategy, in respond to the day-ahead and hour-ahead power change requirements of the grid, respectively. Considerable benefits (e.g., energy and cost savings) can be achieved for both the electricity utilities and building owners under incentive pricing or tariffs. A case study is conducted in a simulation platform to demonstrate the application of the proposed system in an office building

  13. Combination of experimental and simulated small scale solar air-conditioning system

    OpenAIRE

    Thomas, Sébastien; Hennaut, Samuel; Andre, Philippe

    2010-01-01

    It is now clearly assumed that solar assisted air conditioning is able to decrease CO2 production of building operation. One way to evaluate the energy savings potential is the simulation of airconditioning systems. On the other hand, it is also crucial to assess system performance by experimentations. The operation of a solar cooling system in its real environment is considered here. The objective is to evaluate if sun radiation in our region (Western Europe – Belgium) in summ...

  14. Ant-nest corrosion of copper tubing in air-conditioning units

    OpenAIRE

    Bastidas, D. M.; Cayuela, I.; Bastidas, J. M.

    2006-01-01

    Ant-nest corrosion is a specific type of premature failure (2-3 months) of copper tubes used in air-conditioning units causing the loss of refrigerant liquid and the consequent environment pollution. It is known that attack requires the simultaneous presence of moisture, oxygen and a corrodent, usually an organic acid, such as formic, acetic, propionic or butyric acid or other volatile organic substances like methanol, ethanol, formaldehyde or acetoaldehyde. Approximately 10% of all premature...

  15. Is fumigation enough for air conditioning units in operation theatres and Intensive care units?

    OpenAIRE

    Anasua Deb; Sharmila Raut; Sunita Gajbhiye; Priyanka Patil; Sanjay Raut

    2016-01-01

    Background: Strict asepsis is necessary in operating theatres (OT) and intensive care units (ICU) as the patients undergo invasive procedures. The filters of contaminated air conditioning (AC) units provide a niche for proliferation of fungi and production of fungal spores. Methods: The routine procedure for maintenance of sterile atmosphere in our hospital, i.e. fumigation and mopping walls with disinfectants often fail to address these fungal spores of the AC filters. We therefore carri...

  16. HUMAN RESOURCE MANAGEMENT PRACTICES IN REFRIGERATION AND AIR CONDITIONING INDUSTRY IN INDIA

    OpenAIRE

    Dr.Nisar Ahamad Nalband

    2010-01-01

    Over the last 150 years or so, refrigeration’s great strides offered us ways to preserve and cool food, other substances and ourselves. Refrigeration brought distant production centers. It tore down the barriers of climates and seasons. And while it helped to rev up industrial process, it became an industry itself It is understood that the refrigeration and air conditioning industry has been a promising industry for the development of Indian economy and one of the old industry in India too. I...

  17. Clean heating surfaces - a condition for a fuel consumption decrease (air heaters)

    International Nuclear Information System (INIS)

    Unclean heating surface from the water and the flame side has an influence on the exit gas temperature after combustion. That can be noticed from the gas temperature increase, which is a basic indication of the heating surface condition. Unavoidable, the heating surface has to be clean to get a more economical work of the unit. In this paper the means of cleaning air heater heating surfaces from the flame side are given. (author). 2 tabs., 1 fig

  18. An Investigation Into Operating Strategy of Panasonic and LG Electronic in Chinas Air Conditioning Market

    OpenAIRE

    Kong, Wenzhou

    2006-01-01

    Abstract The dissertation investigates into operating strategy of Panasonic and LG Electronic in Chinas air conditioning market. It focuses on studying their entry modes, competitive strategy, and marketing strategy. Due to the characteristics of the study, qualitative research was chosen as research method. Data was collected mainly from published literature, textbooks, company annual report, interviews, and selected cases. The results of the research indicate both Panasonic and LG ...

  19. Indirect Evaporative Pre-Cooled Compressor Cooling System Performance under Various Outdoor Air Humidity Conditions

    OpenAIRE

    Brahmanis, A; Lešinskis, A

    2013-01-01

    The present study is devoted to efficiency evaluation of a combined indirect evaporative – compressor cooling system under various outdoor air humidity conditions of temperate climate. The investigated system is located in the recently restored historical building, The Art Museum Riga Bourse, which was initially built in the middle of the 19th century. The indirect adiabatic chiller supplies cooled fluid to the conventional cooling system, consisting of ventilation cooling coils and fan-coil ...

  20. Air conditioning using an air-cooled single effect lithium bromide absorption chiller: results of a trial conducted in Madrid in August 2005

    OpenAIRE

    Izquierdo, M.; Lizarte, R.; Marcos, J.D.; Gutiérrez, G.

    2008-01-01

    Air conditioning using an air-cooled single effect lithium bromide absorption chiller: results of a trial conducted in Madrid in August 2005 correspondence: Corresponding author. Tel.: + 34 91 871 32 48; fax: + 34 91 871 32 48. (Izquierdo, M.) (Izquierdo, M.) Instituto de Ciencias de la Construccion Eduardo Torroja (CSIC) c/Serrano Galvache 4 - 28033 Madrid--> - SPAIN (Izquierdo, M.) SPAIN (Izquierdo, M.)...

  1. Auditing the European room air-conditioning systems and potential energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Bory, Daniela; Adnot, Jerome; Greco, Carmelo; Marchio, Dominique [Ecole des Mines de Paris, Center for Energy and Processes (France)

    2007-07-01

    Nowadays, the European Community promotes the energy improvement of the air-conditioning (AC) systems through the compulsory inspection of these facilities in the frame of the Energy Performance of Buildings Directive [EPBD, 2002]. Inspection itself is just a motivating mean for the AC actors to improve the energy efficiency of the systems and reduce energy. Therefore, the aim of the inspection is to follow periodically the correct management of the facility through a quick visit of the plant and a study of the available documentation while the aim of the audit is the research of best efficiency improvements which requires further investigations to evaluate and quantify the savings. Audit differs from the common maintenance activities of the facilities, the aim of which is limited to guarantee the basic operation of the plant. There is an overall lack of methodologies specific for air-conditioning and the improvements proposed are seldom proven with scientific rigour. For room air conditioning systems, the impacts of defect during operation due to ageing and neglected maintenance are considered: fouled condenser, charge leaks, compressor performances reduced, fans degradation, filter fouling and additional pressure drop in liquid line are explored. The over consumption due to these defects is evaluated for different building types and French climates. The results allow to define simple methods that can be used by the auditors to estimate the energy savings due to the correction of the defects.

  2. Tourists’ attitudes towards ban on smoking in air-conditioned hotel lobbies in Thailand

    Science.gov (United States)

    Viriyachaiyo, V; Lim, A

    2009-01-01

    Background: Thailand is internationally renowned for its stringent tobacco control measures. In Thailand, a regulation banning smoking in air-conditioned hotel lobbies was issued in late 2006, causing substantial apprehension within the hospitality industry. A survey of tourists’ attitudes toward the ban was conducted. Methods: A cross-sectional survey of 5550 travellers staying in various hotels in Bangkok, Surat Thani, Phuket, Krabi and Songkhla provinces, October 2005 to December 2006. Travellers aged 15 years or older with a check-in duration of at least one day and willing to complete the questionnaire were requested by hotel staff to fill in the 5-minute questionnaire at check-in or later at their convenience. Results: Secondhand cigarette smoke was recognised as harmful to health by 89.7% of respondents. 47.8% of travellers were aware of the Thai regulation banning smoking in air-conditioned restaurants. 80.9% of the respondents agreed with the ban, particularly female non-smokers. 38.6% of survey respondents indicated that they would be more likely to visit Thailand again because of the regulation, 53.4% that the regulation would not affect their decision and 7.9% that they would be less likely to visit Thailand again. Conclusion: Banning smoking in air-conditioned hotel lobbies in Thailand is widely supported by tourists. Enforcement of the regulation is more likely to attract tourists than dissuade them from holidaying in Thailand. PMID:19364754

  3. Possible schemes for solar-powered air-conditioning in 2-storey terrace houses

    International Nuclear Information System (INIS)

    Space cooling is required all year round in the tropics, and probably accounts for a considerable proportion of the cost of electricity. Solar radiation can be channeled into cooling by photovoltaic powered systems and through the relatively new adsorption cycle technology. Two-storey terrace housing appear to have the greatest potential of introducing solar-powered cooling to residential homes. There are two schemes to cool a two-storey terrace housing: 1) By spraying water down the roof a tank, circulated by a pump powered by PV panels on the roof or 2) By replacing the roof with solar hot water collectors and use adsorption cooling chillers to produce air-conditioning for the entire block of terrace houses. In scheme number 1, a preliminary, rough technical evaluation showed that it is possible to pump water to the roof to flow down as a thin film and cool the roof by evaporation to about 40 degree C from about 70 degree C if without water evaporation at the highest insolation rate of the day. Scheme number 2, which uses adsorption chilling technology, requires communal sharing of the air-conditioning facility. The effect of collecting solar heat using the roof is two fold: to absorb solar energy for producing hot water and reducing excess heat input to the house. Preliminary costing demonstrates that solar-powered air-conditioning is within reach of commercialisation, bearing in mind that bulk purchases will dramatically lower the price of a product

  4. Optimal Energy Reduction Schedules for Ice Storage Air-Conditioning Systems

    Directory of Open Access Journals (Sweden)

    Whei-Min Lin

    2015-09-01

    Full Text Available This paper proposes a hybrid algorithm to solve the optimal energy dispatch of an ice storage air-conditioning system. Based on a real air-conditioning system, the data, including the return temperature of chilled water, the supply temperature of chilled water, the return temperature of ice storage water, and the supply temperature of ice storage water, are measured. The least-squares regression (LSR is used to obtain the input-output (I/O curve for the cooling load and power consumption of chillers and ice storage tank. The objective is to minimize overall cost in a daily schedule while satisfying all constraints, including cooling loading under the time-of-use (TOU rate. Based on the Radial Basis Function Network (RBFN and Ant Colony Optimization, an Ant-Based Radial Basis Function Network (ARBFN is constructed in the searching process. Simulation results indicate that reasonable solutions provide a practical and flexible framework allowing the economic dispatch of ice storage air-conditioning systems, and offering greater energy efficiency in dispatching chillers.

  5. Experimental Study of Air Conditioning Unit of Evaporative Cooling Assisted Mechanical Refrigeration

    Institute of Scientific and Technical Information of China (English)

    HUANG Xiang; XU Fang-cheng; WU Jun-mei

    2009-01-01

    The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was con-ducted and analyzed.The test shows that making full use of the evaporative cooling"free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the ener-gY efficiency ratio of the Unit(EER) is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the newwind ratio up to 50 percent.more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.

  6. A basic condition-based maintenance strategy for air-cooled turbine generators

    Energy Technology Data Exchange (ETDEWEB)

    Laird, T; Griffith, G [Mechanical Dynamics and Analysis LLC, Generator Repair Services, Sunset Hills, MO (United States); Hoof, M. [Univ. of Applied Sciences, High Voltage and Power Systems Lab, Kaiserslautern (Germany)

    2005-07-01

    Generator components require regular maintenance to prevent failures. It is important to detect degradation of critical generator components such as stator windings, stator core, rotor windings, rotor retaining rings, generator bearings and high voltage bushings which are all exposed to high stresses. The methods of using condition-based maintenance (CBM) for turbine generators was discussed with particular focus on the maintenance strategy for air-cooled generators. Higher unit rated air-cooled machines typically designed as hydrogen-cooled machines are being used more frequently by the power industry to reduce costs. Since more compact machines are being built to reduce material costs, thermal and electrical design stresses have increased, resulting in higher utilization of the machines and reduced long-term reliability in service. It was noted that CBM will not completely eliminate all forced outage situations, but will greatly reduce their occurrence and will help avoid catastrophic machine situations. This paper outlined basic maintenance strategies for nuclear power plants, major utilities including fossil-fuel power plants, and minor utilities including industrial power plant producers. The economic strategy for air-cooled turbine generators was outlined with reference to unit condition assessment, trending assessed condition of major generator components, and unknown component weaknesses. The CBM maintenance can be applied to all types of power producers that can benefit from an improved, low cost maintenance strategy. Detailed knowledge of the unit design, operational weakness, cost of maintenance and operational capabilities is needed in order to conduct a reliable assessment. 19 refs., 2 figs.

  7. 'TEWI' concept for estimation of the global warming from the refrigerating and air conditioning systems

    International Nuclear Information System (INIS)

    The most applied CFC refrigerants and their HFC alternatives. values of ODP (Ozone Depletion Potential) and GWP (Global Warming Potential) of the most used refrigerants. natural working fluids and their properties. Montreal Protocol and Kyoto Protocol, illogical relations between them concerning to the HFC fluids. Confusion and polemics on the international level about the appliance of HFCs which, by the Kyoto Protocol, are liable to reduction. Introduction of the TEWI concept as a method for estimating the overall influence of refrigerating and air conditioning systems on the greenhouse effect: the direct emission (refrigerant leakage in the atmosphere) and indirect emission as a result of the electrical energy consumption. A demonstration of the TEWI concept on the concrete example in several variants. A discussion about the appliance of the TEWI concept. Meaning of the energy efficiency of the refrigerating systems (indirect CO2 emission). One of the main measures: prevention of refrigerant leakage (direct CO2 emission). A need of permanent education and training courses of the people who work on refrigerating and air conditioning systems. A necessity for constitution of an expert body in the country, preparation of a strategy to lay obligations on the new changes of the Kyoto Protocol and news on the world market. Introduction of country regulations, certification of the companies and people involved in refrigeration and air conditioning. (Author)

  8. Heat pump air conditioning system for pure electric vehicle at ultra-low temperature

    Directory of Open Access Journals (Sweden)

    Li Hai-Jun

    2014-01-01

    Full Text Available When the ordinary heat pump air conditioning system of a pure electric vehicle runs at ultra-low temperature, the discharge temperature of compressor will be too high and the heating capacity of the system will decay seriously, it will lead to inactivity of the heating system. In order to solve this problem, a modification is put forward, and an experiment is also designed. The experimental results show that in the same conditions, this new heating system increases more than 20% of the heating capacity; when the outside environment temperature is negative 20 degrees, the discharge temperature of compressor is below 60 degrees.

  9. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    Science.gov (United States)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  10. An Investigation of Refrigerant Oil Retention in an Air Conditioning System with Two Inverter Compressors in Parallel

    OpenAIRE

    Kuo, Cheng-Shu; Cheng, Wei-Yueh; Hsieh, Wen-Der; Liu, Yangguang

    2012-01-01

    A VRF (variable refrigerant flow) air conditioning, having a number of air handling units connected to an external condensing unit, commonly uses two or more compressors in the system. The complicated piping system of the VRF air conditioning causes difficulties for refrigerant oils to return back to each compressor, especially for compressors operating in different frequencies. Compressors need lubrication in operation process, otherwise the compressor will burn out because of wearing and ov...

  11. The natural gas air-conditioning; La climatisation au gaz naturel. Un avenir prometteur, une technique confirmee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The natural gas air-conditioning market is in growth (it will cover 10% of the market in 2002).To illustrate the possibilities of this energy source, this paper presents three examples of the natural gas air-conditioning in France. The technical aspects, the cost and the advantages of such systems are discussed. (A.L.B.)

  12. Heating, ventilating, and air conditioning deactivation thermal analysis of PUREX Plant

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.W.; Gregonis, R.A. [Westinghouse Hanford Company, Richland, WA (United States)

    1997-08-01

    Thermal analysis was performed for the proposed Plutonium Uranium Extraction Plant exhaust system after deactivation. The purpose of the analysis was to determine if enough condensation will occur to plug or damage the filtration components. A heat transfer and fluid flow analysis was performed to evaluate the thermal characteristics of the underground duct system, the deep-bed glass fiber filter No. 2, and the high-efficiency particulate air filters in the fourth filter building. The analysis is based on extreme variations of air temperature, relative humidity, and dew point temperature using 15 years of Hanford Site weather data as a basis. The results will be used to evaluate the need for the electric heaters proposed for the canyon exhaust to prevent condensation. Results of the analysis indicate that a condition may exist in the underground ductwork where the duct temperature can lead or lag changes in the ambient air temperature. This condition may contribute to condensation on the inside surfaces of the underground exhaust duct. A worst case conservative analysis was performed assuming that all of the water is removed from the moist air over the inside surface of the concrete duct area in the fully developed turbulent boundary layer while the moist air in the free stream will not condense. The total moisture accumulated in 24 hours is negligible. Water puddling would not be expected. The results of the analyses agree with plant operating experiences. The filters were designed to resist high humidity and direct wetting, filter plugging caused by slight condensation in the upstream duct is not a concern. 19 refs., 2 figs.

  13. Sterilization efficacy of ultraviolet irradiation on microbial aerosols under dynamic airflow by experimental air conditioning systems

    International Nuclear Information System (INIS)

    In order to know the sterilization efficacy of ultraviolet irradiation on microbial aerosols, the size and the weight of the aerosol particles were evaluated, and these were irradiated under dynamic air flow created by an experimental air conditioning system. The experimental apparatus consisted of a high efficiency particulate air (HEPA) filter, an aerosol generator, spiral UV lamps placed around a quart glass tube, an Andersen air sampler and a vacuum pump. They were connected serially by stainless steel ducts (85 mm in diameter, 8 m in length). Six types of microbial aerosols generated from an ultrasonic nebulizer were irradiated by UV rays (wavelength 254 nm, mean density 9400 μW/cm2). Their irradiation time ranged from 1.0 to 0.0625 seconds. The microbial aerosols were collected onto the trypticase soy agar (TSA) medium in the Andersen air sampler. After incubation, the number of colony forming units (CFU) were counted, and converted to particle counts. The diameter of microbial aerosol particles calculated by their log normal distribution were found to match the diameter of a single bacteria cell measured by a microscope. The sterilization efficacy of UV in standard airflow conditions (0.5 sec. irradiation) were found to be over 99.5 % in Staphylococcus aureus, Staphylococcus epidermidis, Serratia marcescens, Bacillus subtilis (vegetative cell) and Bacillus subtilis (spore) and 67 % in Aspergillus niger (conidium). In A. niger, which was the most resistant microbe to UV irradiation, the efficacy rose up to 79 % when irradiated for 1.0 sec., and it was observed that the growth speed of the colonies was slower than that of the controls. It was thought that UV rays caused some damage to the proliferation of A. niger cells. (author)

  14. Greenhouse effect: an issue for the refrigeration and air conditioning sector; Effet de serre: quelle problematique pour le froid et le conditionnement de l`air?

    Energy Technology Data Exchange (ETDEWEB)

    Billiard, F. [Institut International du Froid, 75 - Paris (France)

    1997-12-31

    The principles of greenhouse effect and the greenhouse gas main direct and indirect emission sources due to refrigeration and air conditioning systems are first reviewed. Evolution scenarios from 1992 to 2020 and 2100 for the emissions of CFC, HCFC and HFC are presented and related to the Kyoto protocol project limitations; technical improvements in refrigerating and air conditioning systems (lower refrigerant utilization, fluid confinement, alternative technologies, natural refrigerant utilization, etc.) could lead to substantial diminutions of these greenhouse gases

  15. Performance of R-410A Alternative Refrigerants in a Reciprocating Compressor Designed for Air Conditioning Applications

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Vineyard, Edward Allan [ORNL; Mumpower, Kevin [Bristol Compressors International, Inc.

    2016-01-01

    In response to environmental concerns raised by the use of refrigerants with high Global Warming Potential (GWP), the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) has launched an industry-wide cooperative research program, referred to as the Low-GWP Alternative Refrigerants Evaluation Program (AREP), to identify and evaluate promising alternative refrigerants for major product categories. After successfully completing the first phase of the program in December 2013, AHRI launched a second phase of the Low-GWP AREP in 2014 to continue research in areas that were not previously addressed, including refrigerants in high ambient conditions, refrigerants in applications not tested in the first phase, and new refrigerants identified since testing for the program began. Although the Ozone Depletion Potential of R-410A is zero, this refrigerant is under scrutiny due to its high GWP. Several candidate alternative refrigerants have already demonstrated low global warming potential. Performance of these low-GWP alternative refrigerants is being evaluated for Air conditioning and heat pump applications to ensure acceptable system capacity and efficiency. This paper reports the results of a series of compressor calorimeter tests conducted for the second phase of the AREP to evaluate the performance of R-410A alternative refrigerants in a reciprocating compressor designed for air conditioning systems. It compares performance of alternative refrigerants ARM-71A, L41-1, DR-5A, D2Y-60, and R-32 to that of R-410A over a wide range of operating conditions. The tests showed that, in general, cooling capacities were slightly lower (except for the R-32), but energy efficiency ratios (EER) of the alternative refrigerants were comparable to that of R-410A.

  16. Solar desiccant air-conditioning. Practical experience regarding operation and performance

    Energy Technology Data Exchange (ETDEWEB)

    Haller, A.; Trinkl, C.; Wittmann, R.; Zoerner, W. [Ingolstadt Univ. of Applied Sciences (Germany). Kompetenzzentrum Solartechnik; Hanby, V. [De Montfort Univ., Leicester (GB). Inst. of Energy and Sustainable Development (IESD)

    2007-07-01

    The Kompetenzzentrum Solartechnik of Ingolstadt University of Applied Sciences (Centre of Excellence for Solar Engineering) investigates the renewable-only based HVAC system of a multipurpose building. The 10.000 m{sup 2} gross floor area building is part of the biggest logistic-centre in the region serving the AUDI automobile production facilities. On the one hand, the investigation is supposed to demonstrate the potential of solar-assisted cooling, on the other hand, the monitoring, financed by the Bavarian Ministry of Environmental Affairs, focuses on the total energy balance of the building and the various innovative building technologies. Next to a ground source heat pump plant for base-load heating and cooling, the building is equipped with two arrays of solar-thermal flat-plate collectors (100 m{sup 2} of Conergy, Germany, and 180 m{sup 2} of Solahart, Australia) and a desiccant air-conditioning system (DEC, WOLF Anlagen-Technik, Germany). This consists of two plants with an air flow of 8.000 m{sup 3}/h and a nominal cooling capacity of 42 kW each. One of the two plants is monitored. The plant itself is considered a black box in a first approach, i.e. all incoming and outgoing energy flows and the air condition are measured. Apart from the investigation of the performance of the solar-assisted air-conditioning system, the feasibility of DEC-operation using flat-plate collectors available on the market is investigated. (orig.)

  17. Thermodynamic model of a thermal storage air conditioning system with dynamic behavior

    International Nuclear Information System (INIS)

    Highlights: • We developed an automotive thermal storage air conditioning system model. • The thermal storage unit utilizes phase change materials. • We use semi-analytic solution to the coupled phase change and forced convection. • We model the airside heat exchange using the NTU method. • The system model can incorporate dynamic inputs, e.g. variable inlet airflow. - Abstract: A thermodynamic model was developed to predict transient behavior of a thermal storage system, using phase change materials (PCMs), for a novel electric vehicle climate conditioning application. The main objectives of the paper are to consider the system’s dynamic behavior, such as a dynamic air flow rate into the vehicle’s cabin, and to characterize the transient heat transfer process between the thermal storage unit and the vehicle’s cabin, while still maintaining accurate solution to the complex phase change heat transfer. The system studied consists of a heat transfer fluid circulating between either of the on-board hot and cold thermal storage units, which we refer to as thermal batteries, and a liquid–air heat exchanger that provides heat exchange with the incoming air to the vehicle cabin. Each thermal battery is a shell-and-tube configuration where a heat transfer fluid flows through parallel tubes, which are surrounded by PCM within a larger shell. The system model incorporates computationally inexpensive semi-analytic solution to the conjugated laminar forced convection and phase change problem within the battery and accounts for airside heat exchange using the Number of Transfer Units (NTUs) method for the liquid–air heat exchanger. Using this approach, we are able to obtain an accurate solution to the complex heat transfer problem within the battery while also incorporating the impact of the airside heat transfer on the overall system performance. The implemented model was benchmarked against a numerical study for a melting process and against full system

  18. TECNAIRE winter field campaign: turbulent characteristics and their influence on air quality conditions

    Science.gov (United States)

    Yagüe, Carlos; Román Cascón, Carlos; Maqueda, Gregorio; Sastre, Mariano; Arrillaga, Jon A.; Artíñano, Begoña; Diaz-Ramiro, Elías; Gómez-Moreno, Francisco J.; Borge, Rafael; Narros, Adolfo; Pérez, Javier

    2016-04-01

    An urban field campaign was conducted at an air pollution hot spot in Madrid city (Spain) during winter 2015 (from 16th February to 2nd March). The zone selected for the study is a square (Plaza Fernández Ladreda) located in the southern part of the city. This area is an important intersection of several principal routes, and therefore a significant impact in the air quality of the area is found due to the high traffic density. Meteorological data (wind speed and direction, air temperature, relative humidity, pressure, precipitation and global solar radiation) were daily recorded as well as micrometeorological measurements obtained from two sonic anemometers. To characterize this urban atmospheric boundary layer (uABL), micrometeorological parameters (turbulent kinetic energy -TKE-, friction velocity -u∗- and sensible heat flux -H-) are calculated, considering 5-minute average for variance and covariance evaluations. Furthermore, synoptic atmospheric features were analyzed. As a whole, a predominant influence of high pressure systems was found over the Atlantic Ocean and western Spain, affecting Madrid, but during a couple of days (17th and 21st February) some atmospheric instability played a role. The influence of the synoptic situation and specially the evolution of the micrometeorological conditions along the day on air quality characteristics (Particulate Matter concentrations: PM10, PM2.5 and PM1, and NOx concentrations) are analyzed and shown in detail. This work has been financed by Madrid Regional Research Plan through TECNAIRE (P2013/MAE-2972).

  19. Development of a dynamic model for a DX VAV air conditioning system

    International Nuclear Information System (INIS)

    A direct expansion (DX) variable air volume (VAV) air conditioning (A/C) system consists of a VAV air distribution subsystem and a DX refrigeration plant. This paper reports on the development of a representative and complete dynamic mathematical model for the DX VAV A/C system having a variable speed compressor and pressure independent VAV terminals. The model is component based and takes into account the dynamic behaviors of both the DX refrigeration plant and the VAV air distribution subsystem simultaneously. The dynamic model has been developed based on the principles of mass and energy conservation and using correlations describing the operational performance of some of the system's components, which are either field tested or available from manufacturers. An experimental rig has been set up for the DX VAV A/C system, and experimental work has been conducted to obtain the system's responses to the step change of compressor speed. The dynamic model developed was then validated using the experimental data obtained. Steady state and transient responses for five major operating parameters obtained from both the model and the experiment were compared and found to be in good agreement

  20. DISAIN SISTEM KENDALI MESIN AIR LEAK TEST MENGGUNAKAN SISTEM KENDALI PLC OMRON CJ2M DI HVAC (HEATING, VENTILATING, AND AIR CONDITIONING LINE 6

    Directory of Open Access Journals (Sweden)

    Syahril Ardi

    2015-03-01

    Full Text Available Pada proses produksi pembuatan komponen HVAC (Heating, Ventilating, and Air Conditioning dari perusahaan manufaktur di Indonesia, memerlukan proses pengecekan kebocoran pada bagian HVAC. Proses pengecekan ini dilakukan untuk memastikan tidak ada komponen HVAC yang bocor sebelum dikirim ke pihak pelanggan. Penelitian ini dilakukan untuk membuat system dan alat air leak test. Mesin air leak test ini menggunakan prinsip kerja differential pressure air leak test, yaitu metode yang membandingkan antara tekanan udara yang diberikan ke produk dan master produk. Pada penelitian ini, kami membuat disain mesin air leak test menggunakan sistem kendali berupa air leak tester, PLC, dan HMI. Berdasarkan kondisi dengan kapasitas produksi yang meningkat karena bertambahnya permintaan dari customer, dapat ditanggulangi dengan adanya share loading produksi dari HVAC line 4 ke line baru, yaitu HVAC line 6. Hasil yang didapat dari pengujian deteksi kebocoran produk,didapat nilai parameter kebocoran produk sebesar 2.23 ml/min.

  1. Estimating the effects of ambient conditions on the performance of UVGI air cleaners

    Energy Technology Data Exchange (ETDEWEB)

    Lau, Josephine; Bahnfleth, William; Freihaut, James [Indoor Environment Center, Department of Architectural Engineering, The Pennsylvania State University, University Park, PA (United States)

    2009-07-15

    Ultraviolet germicidal irradiation (UVGI) uses UVC radiation produced by low pressure mercury vapor lamps to control biological air contaminants. Ambient air velocity and temperature have a strong effect on lamp output by influencing the lamp surface cold spot temperature. In-duct UVGI systems are particularly susceptible to ambient effects due to the range of velocity and temperature conditions they may experience. An analytical model of the effect of ambient conditions on lamp surface temperature was developed for three common lamp types in cross flow from a convective-radiative energy balance assuming constant surface temperature. For one lamp type, a single tube standard output lamp, UVC output and cold spot temperature data were obtained under typical in-duct operating conditions. Over an ambient temperature range of 10-32.2 C and an air velocity range of 0-3.25 m/s, measured cold spot temperature varied from 12.7 to 41.9 C and measured lamp output varied by 68% of maximum. Surface temperatures predicted by the heat transfer model were 6-17 C higher than corresponding measured cold spot temperatures, but were found to correlate well with cold spot temperature via a two-variable linear regression. When corrected using this relationship, the simple model predicted the cold spot temperature within 1 C and lamp UVC output within {+-}5%. To illustrate its practical use, the calibrated lamp model was employed in a simulation of the control of a contaminant in a single-zone ventilation system by an in-duct UVGI device. In this example, failure to account for the impact of ambient condition effects resulted in under-prediction of average space concentration by approximately 20% relative to a constant output system operating at maximum UVC output. (author)

  2. An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry

    Energy Technology Data Exchange (ETDEWEB)

    Dale, Larry; Millstein, Dev; Coughlin, Katie; Van Buskirk, Robert; Rosenquist, Gregory; Lekov, Alex; Bhuyan, Sanjib

    2004-01-30

    In this report we calculate the change in final consumer prices due to minimum efficiency standards, focusing on a standard economic model of the air-conditioning and heating equipment (ACHE) wholesale industry. The model examines the relationship between the marginal cost to distribute and sell equipment and the final consumer price in this industry. The model predicts that the impact of a standard on the final consumer price is conditioned by its impact on marginal distribution costs. For example, if a standard raises the marginal cost to distribute and sell equipment a small amount, the model predicts that the standard will raise the final consumer price a small amount as well. Statistical analysis suggest that standards do not increase the amount of labor needed to distribute equipment the same employees needed to sell lower efficiency equipment can sell high efficiency equipment. Labor is a large component of the total marginal cost to distribute and sell air-conditioning and heating equipment. We infer from this that standards have a relatively small impact on ACHE marginal distribution and sale costs. Thus, our model predicts that a standard will have a relatively small impact on final ACHE consumer prices. Our statistical analysis of U.S. Census Bureau wholesale revenue tends to confirm this model prediction. Generalizing, we find that the ratio of manufacturer price to final consumer price prior to a standard tends to exceed the ratio of the change in manufacturer price to the change in final consumer price resulting from a standard. The appendix expands our analysis through a typical distribution chain for commercial and residential air-conditioning and heating equipment.

  3. Application of a solar refrigeration system by absorption for the air conditioning of buildings

    Energy Technology Data Exchange (ETDEWEB)

    Machielsen, Cees H. M [Delft University of Technology, Mekelweg (Netherlands); Hagendijk, Andre E [Consultancy and Research (Netherlands)

    2000-07-01

    This paper describes the Sofri project, a cooperation between Ceeran Ltd and The Delft University of Technology. The main objective of this project is to develop the necessary knowledge and experience to commercialize solar-assisted air conditioning and dehumidification systems in the Dutch Caribbean. The project is motivated by the present needs of the Dutch Caribbean for renewable energy sources and the fact that the Caribbean has a high and uniform insolation throughout the year. Furthermore, hotels and offices in this area use more than 40% of their energy for air-conditioning purposes. Therefore solar-assisted air conditioning systems are a logic approach in reducing the energy demand and to lower the peak electricity reducing the energy demands for the local power station. Ceeran Ltd has the objective to reach full commercialization of the proposed technologies in the Dutch Caribbean. The research is concentrated on liquid absorption machines and solar collection systems such as flat plates with selective surfaces, heat pipe evacuated tubes flat plate collectors, and Compound Parabolic Concentrators. The first demonstration unit is planned to be installed in an office building in Curacao. The installation consists of a 35 kW LiBr/H{sub 2}O absorption machine driven by 100 m{sup 2} flat pate collectors with a gas backup system. The system will provide comfort air-conditioning for this these type of office buildings during daytime. [Spanish] Este documento describe el proyecto SOFRI, una cooperacion entre Ceeran, Ltd, y la Universidad Tecnologica del Delft. El principal objetivo de este proyecto es el de desarrollar el conocimiento necesario y la experiencia para comercializar los sistemas de aire acondicionado y deshumidificacion ayudados por la energia solar en el Caribe Holandes. Este proyecto ha sido motivado por las actuales necesidades del Caribe Holandes de fuentes de energia renovable y por el hecho de que el Caribe tiene una alta y uniforme insolacion

  4. Life cycle assessment of a conventional and plastic solar collector in alternative air-conditioning

    International Nuclear Information System (INIS)

    Alternative solar systems include a large number of heat-and mass exchange apparatus (HMTA) with considerable size surfaces. Prequired for realization of the work processes. This result in the increase in the overall dimentions. and cost of the system. The possibility of using the principle of combining the working and auxiliary processes within the (HMTA) has been considred, and the calculation proving the working ability of the alternative system for solving the task of air-condition, obtaining comfort parameters by employing evaporative air-cooling methods only, and a solar system with flat solar collectors to provide for the absorbent regeneration, have been performed. The study shows the importance in using Live Cycle Assessment, study for renewable energy, technologies, where environmental performance is especially important.(Author)

  5. Data mining based sensor fault diagnosis and validation for building air conditioning system

    International Nuclear Information System (INIS)

    A strategy based on the data mining (DM) method is developed to detect and diagnose sensor faults based on the past running performance data in heating, ventilating and air conditioning (HVAC) systems, combining a rough set approach and an artificial neural network (ANN). The reduced information is used to develop classification rules and train the neural network to infer appropriate parameters. The differences between measured thermodynamic states and predicted states obtained from models for normal performance (residuals) are used as performance indices for sensor fault detection and diagnosis. Real test results from a real HVAC system show that only the temperature and humidity measurements of many air handling units (AHU) can work very well as the measurements to distinguish simultaneous temperature sensor faults of the supply chilled water (SCW) and return chilled water (RCW)

  6. Gas Dispersion in Granular Porous Media under Air-Dry and Wet Conditions

    DEFF Research Database (Denmark)

    Naveed, Muhammad; Hamamoto, S; Kawamoto, K;

    2012-01-01

    dispersion and soil physical characteristics. In this study, a series of advection–dispersion experiments was performed on granular porous media to identify the effects of soil column dimensions (length and diameter), particle size and shape, dry bulk density, and moisture content on the magnitude of gas...... dispersion. Glass beads and various sands of different shapes (angular and rounded) with mean particle diameters (d50) ranging from 0.19 to 1.51 mm at both air-dry and variable moisture contents were used as granular porous media. Gas dispersion coefficients and gas dispersivities (a = DH/v, where v is the...... pore-gas velocity) were determined by fitting the advection–dispersion equation to the measured breakthrough curves. For all test conditions, DH increased linearly with v. The test results showed that neither soil column length nor diameter had significant effect on gas dispersivity. Under air...

  7. Influences of the Indoor Environment on Heat, Air, and Moisture Conditions in the Component

    DEFF Research Database (Denmark)

    Steskens, Paul Wilhelmus Maria Hermanus; Rode, Carsten; Janssen, Hans

    2008-01-01

    transfer coefficients strongly depend on the local air velocity, local temperature, water-material interactions, water content at the material surface, and the surface texture of the material. Moreover, due to local heat and moisture sources, imperfect mixing and microclimatic effects, temperature and...... variations of the surface transfer coefficients near the surface of a building component on the HAM conditions in the component. A parameter study has been used to investigate this influence. The research showed that the surface transfer coefficients have a relatively large influence on the redicted HAM...... conditions in a building component. Building researchers and designers should be aware that the ppropriate indoor environmental conditions are applied, when performing a HAM component simulation and analysis....

  8. The Histoty of Ventilation and Air Conditioning is CERN Up to Date with the latest Technological Developments?

    CERN Document Server

    Kühnl-Kinel, J

    2000-01-01

    The invention of ventilation cannot be ascribed to a certain date. It started with simple aeration when man brought fire into his abode and continued through different stages including air cooling using ice to finally arrive at the time when ventilation and air conditioning has become an essential part of our life and plays an important role in human evolution. This paper presents the history of ventilation and air conditioning, explains the key constraints over the centuries, and shows its influence on everyday life. Some examples of previous air-conditioning plants are described and different approaches to the way of calculation of ventilation systems discussed. It gives an overview of the Heating, Ventilation and Air Conditioning (HVAC) installations at CERN and points out their particularities. It also compares them with the latest technological developments in the field as well as showing the new trends that are being applied at CERN.

  9. Air conditioning in the region of Madrid, Spain: an approach to electricity consumption, economics and CO₂emissions

    OpenAIRE

    Izquierdo, Marcelo; Moreno-Rodríguez, A.; González-Gil, A.; García-Hernando, Néstor

    2011-01-01

    An understanding of electricity consumption due to residential air conditioning (AC) may improve production and environmental impact strategy design. This article reports on a study of peak and seasonal electricity consumption for residential air conditioning in the region of Madrid, Spain. Consumption was assessed by simulating the operation of AC units at the outdoor summer temperature characteristics of central Spain. AC unit performance when operating under part load conditions in keep...

  10. Performance Analysis of Air-to-Water Heat Pump in Latvian Climate Conditions

    Science.gov (United States)

    Kazjonovs, Janis; Sipkevics, Andrejs; Jakovics, Andris; Dancigs, Andris; Bajare, Diana; Dancigs, Leonards

    2014-12-01

    Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being -20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the

  11. Commentary: Air-conditioning as a risk for increased use of healthservices

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.

    2004-06-01

    In this issue of the journal, Preziosi et al. [2004] report the first study to assess differences in the utilization of health care related to the presence of air-conditioning in office workplaces. Although the study was simple and cross-sectional, the data variables from questionnaires, and the findings subject to a variety of questions, the findings are striking enough to deserve clarification. The study used a large random national sample of French women assembled for another purpose (to study antioxidant nutrients and prevention of cancer and cardiovascular disease). Participants reported health services and health events in monthly questionnaires over 1 year, and in one questionnaire in the middle of that period also reported whether air-conditioning was in use at their workplace. Fifteen percent of participants reported air-conditioning at work. Analyses adjusting for age and smoking status of participants found increases in most outcomes assessed: use of specific kinds of physicians, sickness absence, and hospital stays. While the increases in odds ratios (OR) and 95% confidence intervals (CI) were statistically significant for only otorhinolaryngology [OR (95% CI) = 2.33 (1.35-4.04)] and sickness absence [1.70 (1.13-2.58)], other increases were notable--dermatology [1.6 (0.98-2.65)]; hospital stay [1.51 (0.92-2.45)], and pneumonology [2.10 (0.65-6.82)]. The least elevated outcomes were for general practice medicine [0.99 (0.65-1.48)] and global medical visits [1.18 (0.67-2.07)]. [Preziosi et al., 2004 ,(Table 2)] Odds ratios for relatively common health outcomes often lie farther from the null than the risk ratios most useful for quantifying the increase in risk. Risk ratios, or prevalence ratios (PRs, the equivalent measure of effect for cross-sectional data), have seldom been used because of the convenience and availability of logistic regression models that estimate odds ratios. With baseline prevalences ranging up to 85.7% in the data from Preziosi et

  12. Vibro-acoustic characterization of flexible hose in CO2 car air conditioning systems

    Science.gov (United States)

    Angelini, F.; Bergami, A.; Martarelli, M.; Tomasini, E. P.

    2008-06-01

    Following the EU directive 2006/40/EC proscribing from 2011 that refrigerant fluids must have a global warming potential not higher than 150, it will not be allowed anymore to employ the current R134a on car air conditioning systems. Maflow s.p.a (automotive hose maker) is developing products for each possible new refrigerant. This paper is focused on hoses for CO2 refrigerants operating in the worst conditions because of the high pressures and temperatures at which they are working (with R134a the high pressure is 18 bar and low pressure is 3 bar; with CO2 the high pressure is 100 bar and low pressure is 35 bar). Therefore the noise emission control of the CO2 air conditioning systems is very important. The aim of this study is to develop a standard measurement method for the vibro - acoustic characterization of High Pressure (HP - Shark F4) and Low Pressure (LP - ULEV) hoses to reduce noise emission and raise car passenger comfort; in particular deep research on high pressure hose. The method is based on the measurement of the vibration level of the hoses in a standard test bench by means of a Laser Doppler Vibrometer (LDV) and its acoustic emission by a sound intensity probe.

  13. Automobile air-conditioning its energy and environmental impact; La climatisation automobile impact energetique et environnemental

    Energy Technology Data Exchange (ETDEWEB)

    Barbusse, St.; Gagnepain, L.

    2003-05-01

    Over the last three decades, automobile manufacturers have made a lot of progress in specific fuel consumption and engine emissions of pollutants. Yet the impact of these improvements on vehicle consumption has been limited by increased dynamic performances (maxi-mum speed, torque), increased safety (power steering and power brakes) and increased comfort (noise and vibration reduction, electric windows and thermal comfort). Because of this, the real CO{sub 2}-emission levels in vehicles is still high in a context where road transport is a major factor in the balance sheet of greenhouse gas emissions, thus in complying with the inter-national climate convention. Although European, Japanese and Korean manufacturers signed an important agreement with the European Commission for voluntarily reducing CO{sub 2} emissions from their vehicles, with a weighted average emission goal by sales of 140 grams per km on the MVEG approval cycle by 2008, it has to be noted that the European procedures for measuring fuel consumption and CO{sub 2} emissions do not take accessories into account, especially air-condition ng (A/C). The big dissemination of this equipment recognized as a big energy consumer and as using a refrigerant with a high global warming potential ed ADEME to implement a set of assessments of A/C's energy and environmental impact. In particular these assessments include studies of vehicle equipment rates, analyses of impact on fuel consumption as well as regulated pollutant emissions in the exhaust, a characterization of the refrigerant leakage levels and an estimate of greenhouse gas emissions for all air-conditioned vehicles. This leaflet summarizes the results of these actions. All of these studies and additional data are presented in greater detail in the document,-'Automobile Air-conditioning' (ADEME reference no. 4985). (author)

  14. Home air-conditioning, traffic exposure, and asthma and allergic symptoms among preschool children.

    Science.gov (United States)

    Zuraimi, Mohamed Sultan; Tham, Kwok-Wai; Chew, Fook-Tim; Ooi, Peng-Lim; Koh, David

    2011-02-01

    Epidemiological data suggest that traffic exposures can influence asthma and allergic symptoms among preschool children; however, there is no information on risk reduction via home air-conditioning (AC). The aim of this study is to evaluate the associations of self-reported traffic densities with asthma and allergic symptoms among preschool children and determine whether AC is an effect modifier. A cross-sectional study adopting an expanded and modified ISAAC--International Study of Asthma and Allergies in Childhood conducted on randomly selected 2994 children living in homes without any indoor risk factors. Specific information on demographics, indoor home risk factors, and traffic variables were obtained. Adjusted prevalence ratios (PR) and 95% confidence interval (CI) were determined by Cox proportional hazard regression model with assumption of a constant risk period controlled for covariates. We found dose-response significant relationships between validated self-reported traffic densities and asthma and rhinitis symptoms. Among children sleeping in non-air-conditioned homes, there were stronger associations between asthma and rhinitis symptoms studied. PRs for heavy traffic density were 2.06 for wheeze (95% CI 0.97-4.38), 2.89 for asthma (1.14-7.32), 1.73 for rhinitis (1.00-2.99), and 3.39 for rhinoconjunctivitis (1.24-9.27). There were no associations found for children sleeping in air-conditioned homes. Our results suggest that AC in the bedroom modifies the health effects of traffic among preschool children. This finding suggests that attention should also be paid to ventilation characteristics of the homes to remediate health-related traffic pollution problems. PMID:20561230

  15. Inspection and auditing of air-conditioning facilities in Europe - A new efficiency target

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, Maxime; Adnot, Jerome [Ecole des Mines de Paris (France).Center for Energy and Processes

    2005-07-01

    In coming years, the European stock of air conditioning equipment in use will partly become obsolete. In 2012, 50% of the Air-Conditioning market of EU-15 will be used to replace existing obsolete equipment (more than 15 years of operation) so that an opportunity exists to introduce higher efficiency systems. Indeed, the EPBD (European Energy Performance of Building Directive) introduced the technical obsolescence as a possible cause of replacement in addition to simple failure. A regular inspection of buildings equipped with Air-Conditioning systems is now obligatory. First of all, the paper details the EPBD Article 9 (European Parliament 2003) on the inspection and explains its scope, objectives and stakes. Indeed, too costly or too frequent inspections could create market distortions by leading building owners to prefer low capacity equipment that can be less energy-efficient. The paper focuses on the definition and the relevance of the 12-kilowatt limit and then on the type of installations included in the scope of that inspection. Despite problems, stakes are important in terms of energy savings because there is a strong link between the inspection and the audit, which is the first step toward Energy-Efficiency. After that first phase, we model inspection and audit markets in the European Union, especially in the five biggest markets. The model shows that the Air-Conditioning market will increase a lot in the future and that present stock will become obsolete very soon. Inspection and audit markets are therefore enormous and Member States have to prepare the transposition as quickly as possible. Last of all, standardisation is one way to accelerate the adoption process for this regulation. The draft standard (CEN 2004) developed by CEN (European Committee of Standardization) is a step in that direction but seems to be imperfect and several questions remain. However, facing with the quantity of buildings and the lack of time, several Member States could adopt

  16. Multi-variable Extremum Seeking Control for Mini-split Air-conditioning System

    OpenAIRE

    Xiao, Yan; Li, Yaoyu; Seem, John E.

    2014-01-01

    In this study, a multi-variable extremum seeking control (ESC) scheme is proposed for a variable-speed mini-split air-conditioning system. The control inputs are the evaporator and condenser fan speeds, respectively, while the total power consumption is used as the feedback. As accurate model is hard and expensive to obtain for the AC system of interest in real time, nearly model-free self-optimizing control methods such as ESC is considered a more feasible solution to practical deployment. R...

  17. Energy saving measures for automotive air conditioning (AC) system in the tropics

    OpenAIRE

    Subiantoro, Alison; Ooi, Kim Tiow; Stimming, Ulrich

    2014-01-01

    Air conditioning (AC) is an integral component of modern cars in the tropics. However, AC usage in this region consumes a large amount of energy. In conventional internal combustion engine cars, it consumes up to 30% of the fuel, while in battery electric cars, AC may reduce the battery range by up to 40%. Fortunately, there are various ways to improve the efficiency of automotive ACs in the tropics. In this paper, three energy saving measures are discussed. These include a higher indoor temp...

  18. Disqualifying Medical Conditions of Flying Personnel in Chinese Army and Air Force

    Institute of Scientific and Technical Information of China (English)

    Chun-wei Wang; Shu-xuan Xu; Xian-rong Xu; Tong-xin Chen

    2008-01-01

    @@ After inpatient aircrews of Chinese Army and Air Force are treated at local hospitals,their health status will be evaluated.If it is aeronantieally adaptable,the conclusion would be flying qualification;if it may impact the flight safety or the flight environment may aggravate the illness,the conclusion would be flight suspension,and then the patient should be forwarded from local hospital to our hospital.After detailed examination,if the conditions of flying personnel are considered not qualified for flight,the conclusion of flying disqualification should be made finally.

  19. Adsorption cold storage system with zeolite-water working pair used for locomotive air conditioning

    International Nuclear Information System (INIS)

    Adsorption cold storage has lately attracted attention for its large storage capacity and zero cold energy loss during the storing process. Thermodynamic and experimental studies on the cold storage capacity and the cold discharging process, in which the adsorber is either air cooled or adiabatic, have been presented. An adsorption cold storage system with zeolite-water working pair has been developed, and some operating results are summarized. This system is used for providing air conditioning for the driver's cab of an internal combustion locomotive. Unlike a normal adsorption air conditioner, the system starts running with the adsorption process, during which the cold energy stored is discharged, and ends running with the generation process. The adsorbent temperature decreases during the cold storing period between two runs. The refrigeration power output for the whole running cycle is about 4.1 kW. It appears that such a system is quite energetically efficient and is comparatively suitable for providing discontinuous refrigeration capacity when powered by low grade thermal energy, such as industrial exhausted heat or solar energy

  20. Thermal properties in phase change wallboard room based on air conditioning cold storage

    Institute of Scientific and Technical Information of China (English)

    陈其针; 刘鑫; 牛润萍; 王琳

    2009-01-01

    By comparing the thermal performance parameters of an ordinary wall room with a phase change wall (PCW) room,the effect of phase change wallboard on the fluctuation of temperature in air-conditioning room in summer was studied. And PCW room and an ordinary wall room,which are cooled by air-conditioner,were built up. Differential scanning calorimetry (DSC) was used to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested,it is found that the mean temperature of PCW is lower than that of ordinary wall room by 1-2 ℃,and PCW can lower the heat flow by 4.6 W/m2. Combining phase change material to building envelope can lower the indoor temperature,make the room thermal comfortable,and cut down the turn-on-and-off frequency of air-conditioner,the primary investment and operating costs. It alleviates urgent need of the electric power. Building envelope which contains phase change wallboard can improve the indoor thermal environment,and decrease energy consumption in buildings. Phase change wallboard can make impressive effect on energy efficiency of buildings.

  1. Experimental study on frosting control of mobile air conditioning system with microchannel evaporator

    International Nuclear Information System (INIS)

    In this paper, a newly developed frost control system is proposed. System bench tests and vehicle test in wind tunnel have been carried out to explore the anti-frosting performance of automotive air conditioning system with microchannel evaporator. The experimental results are compared with the baseline conventional laminated evaporator system. The test results show that the installation position of temperature sensor can dramatically affect the anti-frosting performance. The clutch switching on/off temperature range of the microchannel evaporator is also experimentally studied. The test results show that, with a proper installation position and on/off temperature range, the system COP can be improved, and meanwhile the panel vents' air off temperature can be reduced, and temperature swing can be reduced. - Highlights: → The frost control systems were tested with microchannel and laminated evaporators separately. → The installation position of temperature sensor affects the anti-frosting performance. → Temperature control range affects the anti-frosting performance. → The panel vents' air off temperature and swing can be reduced by proper control parameters. → The system COP can be improved by proper control parameters.

  2. Estimating the risks of smoking, air pollution, and passive smoke on acute respiratory conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ostro, B.D. (California Public Health Foundation, Berkeley (USA))

    1989-06-01

    Five years of the annual Health Interview Survey, conducted by the National Center for Health Statistics, are used to estimate the effects of air pollution, smoking, and environmental tobacco smoke on respiratory restrictions in activity for adults, and bed disability for children. After adjusting for several socioeconomic factors, the multiple regression estimates indicate that an independent and statistically significant association exists between these three forms of air pollution and respiratory morbidity. The comparative risks of these exposures are computed and the plausibility of the relative risks is examined by comparing the equivalent doses with actual measurements of exposure taken in the homes of smokers. The results indicate that: (1) smokers will have a 55-75% excess in days with respiratory conditions severe enough to cause reductions in normal activity; (2) a 1 microgram increase in fine particulate matter air pollution is associated with a 3% excess in acute respiratory disease; and (3) a pack-a-day smoker will increase respiratory restricted days for a nonsmoking spouse by 20% and increase the number of bed disability days for young children living in the household by 20%. The results also indicate that the estimates of the effects of secondhand smoking on children are improved when the mother's work status is known and incorporated into the exposure estimate.

  3. A Closed-Loop Control Strategy for Air Conditioning Loads to Participate in Demand Response

    Directory of Open Access Journals (Sweden)

    Xiaoqing Hu

    2015-08-01

    Full Text Available Thermostatically controlled loads (TCLs, such as air conditioners (ACs, are important demand response resources—they have a certain heat storage capacity. A change in the operating status of an air conditioner in a small range will not noticeably affect the users’ comfort level. Load control of TCLs is considered to be equivalent to a power plant of the same capacity in effect, and it can significantly reduce the system pressure to peak load shift. The thermodynamic model of air conditioning can be used to study the aggregate power of a number of ACs that respond to the step signal of a temperature set point. This paper analyzes the influence of the parameters of each AC in the group to the indoor temperature and the total load, and derives a simplified control model based on the two order linear time invariant transfer function. Then, the stability of the model and designs its Proportional-Integral-Differential (PID controller based on the particle swarm optimization (PSO algorithm is also studied. The case study presented in this paper simulates both scenarios of constant ambient temperature and changing ambient temperature to verify the proposed transfer function model and control strategy can closely track the reference peak load shifting curves. The study also demonstrates minimal changes in the indoor temperature and the users’ comfort level.

  4. PRINCIPLES OF IMPROVEMENT OF AIR TRAFFIC FLOW AND CAPACITY MANAGEMENT IN TERMINAL CONTROL AREAS UNDER UNCERTAINTY CONDITIONS

    OpenAIRE

    Kharchenko, Volodymyr; National Aviation University, Kyiv, Ukraine; Ningbo University of Technology, Ningbo, Zhejiang, China; Chynchenko, Yuriy; National Aviation University, Kyiv

    2013-01-01

    The article deals with the analysis of the researches conducted in the field of the air traffic flow and capacity management in terminal control areas under uncertainty conditions. Traffic flows indicators, uncertainty factors and air traffic flow management in terminal control areas have been reviewed. Principles of improvement of air traffic flow and capacity management in terminal control areas have been analysed and conclusions regarding Ukrainian aeronautical system have been proposed

  5. Comparison of boundary conditions from Global Chemistry Model (GCM) for regional air quality application

    Science.gov (United States)

    Lam, Yun Fat; Cheung, Hung Ming; Fu, Joshua; Huang, Kan

    2015-04-01

    Applying Global Chemistry Model (GCM) for regional Boundary Conditions (BC) has become a common practice to account for long-range transport of air pollutants in the regional air quality modeling. The limited domain model such as CMAQ and CAMx requires a global BC to prescribe the real-time chemical flux at the boundary grids, in order to give a realistic estimate of boundary impacts. Several GCMs have become available recently for use in regional air quality studies. In this study, three GCM models (i.e., GEOS-chem, CHASER and IFS-CB05 MACC provided by Seoul National University, Nagoya University and ECWMF, respectively) for the year of 2010 were applied in CMAQ for the East Asia domain under the framework of Model Inter-comparison Study Asia Phase III (MISC-Asia III) and task force on Hemispheric Transport of Air Pollution (HTAP) jointed experiments. Model performance evaluations on vertical profile and spatial distribution of O3 and PM2.5 have been made on those three models to better understand the model uncertainties from the boundary conditions. Individual analyses on various mega-cities (i.e., Hong Kong, Guangzhou, Taipei, Chongqing, Shanghai, Beijing, Tianjin, Seoul and Tokyo) were also performed. Our analysis found that the monthly estimates of O3 for CHASER were a bit higher than GEOS-Chem and IFS-CB05 MACC, particularly in the northern part of China in the winter and spring, while the monthly averages of PM2.5 in GEOS-Chem were the lowest among the three models. The hourly maximum values of PM2.5 from those three models (GEOS-Chem, CHASER and IFS-CB05 MACC are 450, 321, 331 μg/m3, while the maximum O3 are 158, 212, 380 ppbv, respectively. Cross-comparison of CMAQ results from the 45 km resolution were also made to investigate the boundary impacts from the global GCMs. The results presented here provide insight on how global GCM selection influences the regional air quality simulation in East Asia.

  6. Arduino-based control system for measuring ammonia in air using conditionally-deployed diffusive samplers

    Science.gov (United States)

    Ham, J. M.; Williams, C.; Shonkwiler, K. B.

    2012-12-01

    Arduino microcontrollers, wireless modules, and other low-cost hardware were used to develop a new type of air sampler for monitoring ammonia at strong areal sources like dairies, cattle feedlots, and waste treatment facilities. Ammonia was sampled at multiple locations on the periphery of an operation using Radiello diffusive passive samplers (Cod. RAD168- and RAD1201-Sigma-Aldrich). However, the samplers were not continuously exposed to the air. Instead, each sampling station included two diffusive samplers housed in specialized tubes that sealed the cartridges from the atmosphere. If a user-defined set of wind and weather conditions were met, the Radiellos were deployed into the air using a micro linear actuator. Each station was solar-powered and controlled by Arduinos that were linked to a central weather station using Xbee wireless modules (Digi International Inc.). The Arduinos also measured the total time of exposure using hall-effect sensors to verify the position of the cartridge (i.e., deployed or retracted). The decision to expose or retract the samplers was made every five minutes based on wind direction, wind speed, and time of day. Typically, the diffusive samplers were replaced with fresh cartridges every two weeks and the used samplers were analyzed in the laboratory using ion chromatography. Initial studies were conducted at a commercial dairy in northern Colorado. Ammonia emissions along the Front Range of Colorado can be transported into the mountains where atmospheric deposition of nitrogen can impact alpine ecosystems. Therefore, low-cost air quality monitoring equipment is needed that can be widely deployed in the region. Initial work at the dairy showed that ammonia concentrations ranged between 600 to 1200 ppb during the summer; the highest concentrations were downwind of a large anaerobic lagoon. Time-averaged ammonia concentrations were also used to approximate emissions using inverse dispersion models. This methodology provides a

  7. Aspects Related to the Control of the Secondary Flow of Water in Centralized Air Conditioning

    Directory of Open Access Journals (Sweden)

    Hechavarría-Hernández J.R.

    2012-07-01

    Full Text Available In this paper the tuning of the proportional integral controller, incorporated in the variable frequency drive implemented on the secondary variable flow system of cold water of the centralized air conditioning system of a Hotel is carried out. The proportional gain and the time of integration that guarantee a minimum error of one kPa in the control of pressure were defined. A focus multi-variable of the system is presented. It is defined the structure of artificial neural network that better it predicts the behaviour of the pressure, the power and return temperature with an adjustment of 94%. It is determined that there is a saving of 13% of electric power, in similar operation conditions, when using a control for closed loop with respect to a control for open loop.

  8. Experimental investigation on steam condensation in the presence of air and helium: forced convection conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bucci, M., E-mail: matteo.bucci@cea.fr [Univ. of Pisa, DIMNP, Pisa (Italy); CEA Saclay, CEA/DEN/DANS/DM2S/SFME/LETR (France); Ambrosini, W.; Forgione, N. [Univ. of Pisa, DIMNP, Pisa (Italy); Lioce, D [Univ. of Pisa, DIMNP, Pisa (Italy); Westinghouse Electric Belguim, Nivelles (Belgium)

    2011-07-01

    This paper discusses the results obtained from recent experimental investigations devoted to the study of steam condensation in the presence of air and a light noncondensable gas. The experiments are intended to provide data for the validation of engineering models and CFD codes. The original experimental data herein discussed focus on forced convection turbulent boundary layer conditions and involve atmospheric pressure, different conditions for mixture velocity (from 1.5 to 3.5 m/s), mixture composition (form 0 to 75 per cent of the light species in the overall amount of noncondensable gases) and two nominal electrical power supply of the steam generator. The experimental data are qualified against correlations based on the heat and mass transfer analogy and to the predictions obtained by an in house condensation model implemented in a commercial CFD code. (author)

  9. Experimental investigation on steam condensation in the presence of air and helium: forced convection conditions

    International Nuclear Information System (INIS)

    This paper discusses the results obtained from recent experimental investigations devoted to the study of steam condensation in the presence of air and a light noncondensable gas. The experiments are intended to provide data for the validation of engineering models and CFD codes. The original experimental data herein discussed focus on forced convection turbulent boundary layer conditions and involve atmospheric pressure, different conditions for mixture velocity (from 1.5 to 3.5 m/s), mixture composition (form 0 to 75 per cent of the light species in the overall amount of noncondensable gases) and two nominal electrical power supply of the steam generator. The experimental data are qualified against correlations based on the heat and mass transfer analogy and to the predictions obtained by an in house condensation model implemented in a commercial CFD code. (author)

  10. Air conditioning of operating theatres - new strategies; OP-Klimatisierung im Umbruch

    Energy Technology Data Exchange (ETDEWEB)

    Teuber, M. [Ebert-Ingenieure, Nuernberg (Germany)

    2004-04-01

    New air conditioning strategies ensure more hygienic conditions, so that the 'protected area' becomes larger to include the whole inner working area. The result is a clean room of 3.2 x 3.2 m with a H14 filter, tissue outlet and lateral shielding which ensures laminar, low-turbulence displacement flow. (orig.) [German] Die lange bekannten Maengel bei der OP-Klimatisierung koennen nun mit Zustimmung der Hygiene beseitigt werden. Das logische System welches sich daraus ergibt, ist, dass der 'Schutzbereich', in dem operiert wird, wesentlich vergroessert wird, und damit den gesamten inneren Arbeitsbereich erfasst. Es wird ein Reinraumbereich von 3,20 x 3,20 m mit endstaendigem Flaechenfilter Klasse H14, Gewebeauslass und seitlicher Abschirmung geschaffen, welcher eine laminare turbulenzarme Verdraengungsstroemung gewaehrleistet. (orig.)

  11. A thermodynamic evaluation of chilled water central air conditioning systems using artificial intelligence tools

    Directory of Open Access Journals (Sweden)

    Juan Carlos Armas

    2011-05-01

    Full Text Available  An analysis of a chilled water central air conditioning system is presented. The object was to calculate main cycle component irreversibility, as well as evaluating this indicator’s sensitivity to operational variations. Artificial neural networks (ANN, genetic algorithms (GA and Matlab tools were used to calculate refrigerant thermodynamic properties during each cycle stage. These tools interacted with equations describing the system’s thermodynamic behaviour. Refrigerant temperature, when released from the compressor, was determined by a hybrid model combining the neural model with a simple genetic algorithm used as optimisation tool; the cycle’s components which were most sensitive to changes in working conditions were identified. It was concluded that the compressor, evaporator and expansion mechanism (in that order represented significant exergy losses reaching 85.62% of total system irreversibility. A very useful tool was thus developed for evaluating these systems. 

  12. 下送风空调房间的数值模拟%Numerical Simulation of a under Floor Air Supply Air-conditioned Room

    Institute of Scientific and Technical Information of China (English)

    刘行安; 张国强; 何雪强

    2012-01-01

    A design method for under floor supply air conditioning system is introduced,and an air-conditioned room designed by the method was analyzed through numerical simulation with software Airpak.Three conclusions are drawn from the results: air in the under floor air supply air-conditioned room shows clear temperature stratification in the vertical direction with lower temperature in the working area beneath,which makes it possible to save more energy than conventional whole room air conditioning system;human thermal comfort is improved in the working area beneath;air quality in the working area is improved as a result of lower air age.Simulation results prove that this design method is efficient and reliable.%介绍了一种下送风空调系统的设计方法,利用Airpak软件对该设计方法下的空调房间进行数值模拟分析。通过模拟结果得到,下送风空调房间在垂直方向出现温度分层现象,下部工作区温度较低,这使得下送风空调比传统全室性空调系统节能;下送风空调在下部工作区具有较好的热舒适性;下部工作区空气龄较小,能够改善工作区的空气品质。模拟结果证实了该设计方法可靠有效。

  13. Statistical framework to simulate daily rainfall series conditional on upper-air predictor variables

    Science.gov (United States)

    Langousis, Andreas; Kaleris, Vassilios

    2014-05-01

    We propose a statistical framework to generate synthetic rainfall time series at daily resolution, conditional on predictor variables indicative of the atmospheric circulation at the mesoscale. We do so by first introducing a dimensionless measure to assess the relative influence of upper-air variables at different pressure levels on ground-level rainfall statistics, and then simulating rainfall occurrence and amount by proper conditioning on the selected atmospheric predictors. The proposed scheme for conditional rainfall simulation operates at a daily time step (avoiding discrete approaches for identification of weather states), can incorporate any possible number and combination of predictor variables, while it is capable of reproducing rainfall seasonality directly from the variation of upper-air variables, without any type of seasonal analysis or modeling. The suggested downscaling approach is tested using atmospheric data from the ERA-Interim archive and daily rainfall measurements from western Greece. The model is found to accurately reproduce several statistics of actual rainfall time series, at both annual and seasonal levels, including wet day fractions, the alternation of wet and dry intervals, the distributions of dry and wet spell lengths, the distribution of rainfall intensities in wet days, short-range dependencies present in historical rainfall records, the distribution of yearly rainfall maxima, dependencies of rainfall statistics on the observation scale, and long-term climatic features present in historical rainfall records. The suggested approach is expected to serve as a useful tool for stochastic rainfall simulation conditional on climate model outputs at a regional level, where climate change impacts and risks are assessed.

  14. Theoretical energy saving analysis of air conditioning system using heat pipe heat exchanger for Indian climatic zones

    Directory of Open Access Journals (Sweden)

    T.S. Jadhav

    2015-12-01

    Full Text Available Heat pipe heat exchanger (HPHX is an excellent device used for heat recovery in air conditioning systems. The Energy Conservation Building Code (ECBC – Bureau of Energy Efficiency (BEE India classifies Indian climatic zones into five categories viz., Hot and Dry (e.g. Ahmedabad, Jodhpur etc, Warm and Humid (e.g. Mumbai, Chennai etc, Composite (e.g. Nagpur, Jaipur etc, Cold (e.g. Guwahati etc and Temperate (e.g. Bengaluru etc. The literature review indicated that very limited information is available on annual energy saving analysis of air conditioning system with HPHX for Indian climatic zones. The paper investigates the possible energy savings using HPHX for heat recovery in air conditioning system for Indian climatic zones. The analysis is carried out for total 25 Indian cities representing different climatic zones. The analysis is performed for a 6 row HPHX and assuming outdoor air quantity as 1 m3/s, return air dry bulb temperature as 23 °C and compressor power as 1 kW/TR. This paper discusses the use of HPHX only for the heat recovery application (exchange of sensible heat between fresh outdoor air and conditioned return air. The annual energy savings with HPHX for a particular city is calculated for number of hours when outdoor air dry bulb temperature exceeds 25 °C. The maximum energy saving potential is revealed for hot and dry, warm and humid and composite Indian climatic zones.

  15. Visibility characteristics and the impacts of air pollutants and meteorological conditions over Shanghai, China.

    Science.gov (United States)

    Xue, Dan; Li, Chengfan; Liu, Qian

    2015-06-01

    In China, visibility condition has become an important issue that concerns both society and the scientific community. In order to study visibility characteristics and its influencing factors, visibility data, air pollutants, and meteorological data during the year 2013 were obtained over Shanghai. The temporal variation of atmospheric visibility was analyzed. The mean value of daily visibility of Shanghai was 19.1 km. Visibility exhibited an obvious seasonal cycle. The maximum and minimum visibility occurred in September and December with the values of 27.5 and 7.7 km, respectively. The relationships between the visibility and air pollutant data were calculated. The visibility had negative correlation with NO2, CO, PM2.5, PM10, and SO2 and weak positive correlation with O3. Meteorological data were clustered into four groups to reveal the joint contribution of meteorological variables to the daily average visibility. Usually, under the meteorological condition of high temperature and wind speed, the visibility of Shanghai reached about 25 km, while visibility decreased to 16 km under the weather type of low wind speed and temperature and high relative humid. Principle component analysis was also applied to identify the main cause of visibility variance. The results showed that the low visibility over Shanghai was mainly due to the high air pollution concentrations associated with low wind speed, which explained the total variance of 44.99 %. These results provide new knowledge for better understanding the variations of visibility and have direct implications to supply sound policy on visibility improvement in Shanghai. PMID:25980729

  16. Characteristic Evaluation on the Cooling Performance of an Electrical Air Conditioning System Using R744 for a Fuel Cell Electric Vehicle

    OpenAIRE

    Moo-Yeon Lee; Hong-Phil Won; Ho-Seong Lee

    2012-01-01

    The objective of this study was to investigate the cooling performance characteristics of an electrical air conditioning system using R744 as an alternative of R-134a for a fuel cell electric vehicle. In order to analyze the cooling performance characteristics of the air conditioning system using R744 for a fuel cell electric vehicle, an electrical air conditioning system using R744 was developed and tested under various operating conditions according to both inlet air conditions of the gas c...

  17. Gas Engine-Driven Heat Pump Chiller for Air-Conditioning and Hot Water Supply Systems

    Science.gov (United States)

    Fujita, Toshihiko; Mita, Nobuhiro; Moriyama, Tadashi; Hoshino, Norimasa; Kimura, Yoshihisa

    In Part 1 of this study, the performance characteristics of a 457kW gas engine-driven heat pump (GHP) chiller have been obtained from a simulation model analysis for both cooling and heating modes and it has been found that the part-load characteristics of the GHP chiller are fairly well. On the back of Part 1, a computer simulation program has been developed for the evaluation of GHP chiller systems to compare with the other types of heat source systems for air-conditioning and hot water supply applications. The simulation program can be used to estimate annual energy consumption, annual CO2 emission, etc. of the systems with the data of monthly and hourly thermal loads on various buildings, outdoor air conditions, and characteristics of various components comprising the systems. By applying this to some cases of medium-scale hotel, office, shop, and hospital buildings, it has been found that the GHP chiller systems have advantages particularly in the cases of hotels and hospitals where a lot of hot water demand exists. It has also been found that the combination of a GHP chiller and a direct-fired absorption water chiller boiler (hot and chilled water generator) appears promising.

  18. Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nihar K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wei, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Letschert, Virginie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Phadke, Amol A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-10-01

    Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere,1 mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel.

  19. Investigation on solar desiccant dehumidification process for energy conservation of central air-conditioning systems

    International Nuclear Information System (INIS)

    This paper presents the numerical simulation results of an open cycle liquid desiccant dehumidification system, attempts to obtain the best configurations of the solar assisted air-conditioning system and to validate the feasibility of using a liquid desiccant dehumidification system to handle the latent load and improve the energy efficiency of HVAC systems. Firstly, based on the steady state simulation model of a solar collector/regenerator (C/R) system, the energy performance for using exhaust air to regenerate the weak desiccant solution and heating the solution to a temperature higher than the equilibrium value were tested and discussed for different lengths of the collector/regenerator panels. It was found that the thermodynamic performance was significantly improved and it was possible to shorten the length of the solar C/R without degrading the performance greatly. Secondly, the transient performance of the open cycle liquid desiccant dehumidification system was simulated for the weather conditions of Hong Kong. The energy saving, compared with a conventional vapor compression system, is in the range of 25-50%. The higher the portion of latent load in the total ventilation load, the more the energy saving

  20. Research on phase-change material building mass applied in the air-conditioning field

    Institute of Scientific and Technical Information of China (English)

    YANQuanying

    2003-01-01

    Phase-change material building mass contains phase-change matenals. It can decrease air-conditioning load and indoor temperature fluctuations, and improve comfort degree in summer because of thermal storage property of phase-change material. Thereby, the scale, initial investment and operational cost of air-conditioning system decrease effectively. The indoor surroundings improve. In this paper, suitable phase-change material used in architecture and combination mode between phase change material and architectural material were studied. By considering the properties of materials, such as phase-change temperature, phase-change latent heat, thermal conductivity and expansion coefficient, phase-change materials were selected and evaluated. Combination mode between phase-change material and architectural material were provided. The influence of phase-change material structure on thermal performance in room and energy-saving effect were analyzed and compared with traditional structure without phase-change material. It is proved that phase-change material structure is feasible in the practical engineenng. These provide the basis for developing phase-change material building mass.

  1. Experimental verification of a condenser with liquid–vapor separation in an air conditioning system

    International Nuclear Information System (INIS)

    Three liquid–vapor separation condensers (LSC) were tested to evaluate their ability to automatically separate the liquid and vapor during condensation. Each was used in a split-type air conditioner to investigate the performance. The performance of the LSC system having the greatest cooling capacity and energy efficiency ratio (EER) was then compared with that of the system having a baseline fin-and-tube condenser for various ambient temperatures from 29 °C to 43 °C. The results showed that both the cooling capacity and EER of the two systems were almost the same at the three standard conditions in the Chinese standard GB/T 7725-2004, with the LSC having just 67% of the heat transfer area of the baseline condenser. In addition, the LSC system was charged with only 80% of the refrigerant in the baseline system. -- Highlights: ► We tested three liquid–vapor separation condensers in an air conditioning system. ► The best system had the most uniform wall temperature and the smallest pressure drop. ► The LSC system performance with only 67% condenser area was as good as the baseline system. ► LSC system operations are compared for various outdoor temperatures

  2. Burnout behaviour of bituminous coals in air-staged combustion conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kluger, F.; Spliethoff, H.; Hein, K.R.G. [University of Stuttgart, Stuttgart (Germany). Inst. of Process Engineering and Power Plant (IVD)

    2001-07-01

    In order to determine the influence on burnout by the combustion conditions and the coal preparation, three bituminous coals sold on the world market, from three different locations in Poland, South Africa, and Australia, were studied more closely. For this purpose, the coals were ground in two different particle size ranges, which, besides the influence of the combustion conditions, such a temperature, residence time, and stoichiometry, made it possible to also investigate the impact on burnout by the coal preparation. The experiments were carried out in an electrically heated entrained-flow reactor with a thermal input of 8.5 kW. The parameters for the experiments are wall temperature (1000-1350{degree}C), air ratio (0.6-1.15) and two particle sizes (70% {lt} 75 {mu}m, 90% {lt} 75 {mu}m). The results show that in general, for increasing temperatures, the burnout quality will improve. For the Australian Illawara coal, another outcome is increased NOx emissions. Lowering the air ratio in the reduction zone leads to less NOx emission but to increased unburnt matter in ash. For the smaller particle size fraction, the analysis of the different particle sizes shows an improvement of the burnout without a change in NOx emissions. 10 refs., 10 figs., 2 tabs.

  3. Energy performance and optimal control of air-conditioned buildings with envelopes enhanced by phase change materials

    International Nuclear Information System (INIS)

    Highlights: → Impact of PCM on the energy consumption and peak load demand as well as electricity cost of air-conditioned buildings. → Impact of load shifting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Impact of demand limiting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Energy/cost effects of different control strategies and use of PCM in energy-plus-demand-based pricing policy. → Energy/cost effects of different control strategies and use of PCM in time-based pricing policy. - Abstract: Studies are conducted to investigate the impacts of shape-stabilized phase change material (SSPCM) and different control strategies on the energy consumption and peak load demand as well as electricity cost of building air-conditioning systems at typical summer conditions in two climates (subtropical and dry continental climates). An office building using a typical variable air volume (VAV) air-conditioning system was selected and simulated as the reference building in this study. Its envelopes were enhanced by integrating the SSPCM layers into its walls while the air-conditioning system and other configurations of the building remained unchanged. The building system was tested under two typical weather conditions and two typical electricity pricing policies (i.e. time-based pricing and energy-plus-demand-based pricing). Test results show that the use of SSPCM in the building could reduce the building electricity cost significantly (over 11% in electricity cost reduction and over 20% in peak load reduction), under two pricing policies by using load shifting control and demand limiting control respectively. This paper presents the test results and the evaluation on the energy performance and the optimal control strategies of air-conditioned commercial buildings with envelopes enhanced by SSPCM.

  4. Effect of Refrigerant Charge, Compressor Speed and Air Flow Through the Evaporator on the Performance of an Automotive Air Conditioning System

    OpenAIRE

    Datta, Santanu Prasad; Das, Prasanta Kumar; Mukhopadhyay, Siddhartha

    2014-01-01

    During last few decades research on Automotive Air Conditioning System (AACS) reached a milestone in terms of comfort, safety and economy. However investigation on system performance due to AACS’s variable operating conditions is limited. The performance of any AACS mostly depends on compressor speed, blower speed, refrigerant charge level and ambient condition. However, the combined effect of these parameters on the performance of AACS could be non-intuitive. Reduction in compressor speed an...

  5. Energy problems of the central systems of air conditioning; Problemas energeticos de los sistemas centrales de climatizacion

    Energy Technology Data Exchange (ETDEWEB)

    Cardero Corria, Gaspar [Cubanacan, S.A., Varadero (Cuba)

    2003-07-01

    The central systems of air conditioning are widely used in air conditioning production for several reasons among which excel: 1) Better aesthetic of the building, 2) Less noise in the air conditioning premises and 3) Greater yield of the consumed energy. This is indeed the third reason in which this paper will try to contribute with elements that will allow reveal the problem and to identify some possible causes that originate it. The centralized systems of air conditioning must produce conditioned air with lesser power cost than the individual systems, it is that saving which allows to recover an investment that normally surpasses them in 3 to 5 times. Nevertheless, the real numbers do not demonstrate that. [Spanish] Los sistemas centrales de climatizacion son ampliamente usados en la produccion de aire acondicionado por varias razones entre las que sobresalen: 1) Mejor estetica del edificio, 2) Menor ruido en los locales climatizados y 3) Mayor rendimiento de la energia consumida. Es precisamente la tercera razon en la cual este trabajo intentara aportar elementos que permitan develar el problema e identificar algunas posibles causas que lo originan. Los sistemas centralizados de climatizacion deben producir aire acondicionado con un menor gasto energetico que los sistemas individuales, es precisamente ese ahorro lo que permite recuperar una inversion que normalmente los supera en 3 a 5 veces. Sin embargo, los numeros reales no demuestran eso.

  6. Air conditioning on turbo-generator input using waste heat of pyrolysis technology of solid domestic waste utilization

    OpenAIRE

    Ryzhkov, Serhiy S.; Markina, Liudmyla M.; Serbin, Serhii I.; Radchenko, Mykola I.

    2014-01-01

    The efficiency is studied of using waste heat of condensation of utilization technology of solid domestic waste by means of pyrolysis for air conditioning (cooling with drying) on the input of the turbo-generator which works at pyrolysis gas.

  7. Numerical simulation and performance assessment of an absorption solar air-conditioning system coupled with an office building

    OpenAIRE

    Thomas, Sébastien; Andre, Philippe

    2010-01-01

    To minimize environmental impact and CO2 production associated with air-conditioning, it is reasonable to evaluate the prospects of a clean energy source. Solar energy, via thermal collectors can provide a part of the heating needs. Moreover, it can drive absorption chiller in order to satisfy the cooling needs of buildings. The objective of the work is to evaluate accurately the energy consumption of an air conditioning system including a solar driven absorption chiller. The c...

  8. Comparison and Evaluation of a New Innovative Drive Concept for the Air Conditioning Compressor of Electric Vehicles

    OpenAIRE

    Aurich, Joerg; Baumgart, Rico; Danzer, Christoph; Ackermann, Jan

    2014-01-01

    The development of an energy efficient air conditioning system for electric vehicles is an ever increasing challenge, because the cooling as well as the heating of the passenger cell reduces the cruising range dramatically. Almost always the compressor of the air conditioning system in electric cars is a scroll compressor with a separate electric motor and appropriate power electronics. However, this solution is critical in terms of the installation space, the weight and also the costs. There...

  9. COP Prediction of an ejector refrigeration cycle combined with a vapour compression cycle for automotive air conditioning

    OpenAIRE

    Nat Suvarnakuta; Nutthanun Keerlatiyadatanapat; Thanarath Sriveerakul

    2014-01-01

    This paper presents the COP prediction of an ejector refrigeration cycle combined with a vapour compression cycle for automotive air conditioning. Using computational fluid dynamics (CFD) technique, the performance of an ejector was analyzed in term of the entrainment ratio (Rm) and critical back pressure (CBP). The results from this study were compared with a previous study of combined ejector refrigeration system for automotive air conditioning application [1] which the entrainment ratio (R...

  10. Influence of operating conditions on the air gasification of dry refinery sludge in updraft gasifier

    Science.gov (United States)

    Ahmed, R.; Sinnathambi, C. M.

    2013-06-01

    In the present work, details of the equilibrium modeling of dry refinery sludge (DRS) are presented using ASPEN PLUS Simulator in updraft gasifier. Due to lack of available information in the open journal on refinery sludge gasification using updraft gasifier, an evaluate for its optimum conditions on gasification is presented in this paper. For this purpose a Taguchi Orthogonal array design, statistical software is applied to find optimum conditions for DRS gasification. The goal is to identify the most significant process variable in DRS gasification conditions. The process variables include; oxidation zone temperature, equivalent ratio, operating pressure will be simulated and examined. Attention was focused on the effect of optimum operating conditions on the gas composition of H2 and CO (desirable) and CO2 (undesirable) in terms of mass fraction. From our results and finding it can be concluded that the syngas (H2 & CO) yield in term of mass fraction favors high oxidation zone temperature and at atmospheric pressure while CO2 acid gas favor at a high level of equivalent ratio as well as air flow rate favoring towards complete combustion.

  11. The effect of simulated air conditions on N95 filtering facepiece respirators performance.

    Science.gov (United States)

    Ramirez, Joel A; O'Shaughnessy, Patrick T

    2016-07-01

    The objective of this study was to determine the effect of several simulated air environmental conditions on the particle penetration and the breathing resistance of two N95 filtering facepiece respirator (FFR) models. The particle penetration and breathing resistance of the respirators were evaluated in a test system developed to mimic inhalation and exhalation breathing while relative humidity and temperature were modified. Breathing resistance was measured over 120 min using a calibrated pressure transducer under four different temperature and relative humidity conditions without aerosol loading. Particle penetration was evaluated before and after the breathing resistance test at room conditions using a sodium chloride aerosol measured with a scanning mobility particle sizer. Results demonstrated that increasing relative humidity and lowering external temperature caused significant increases in breathing resistance (p < 0.001). However, these same conditions did not influence the penetration or most penetrating particle size of the tested FFRs. The increase in breathing resistance varied by FFR model suggesting that some FFR media are less influenced by high relative humidity. PMID:26861653

  12. Risk Assessment of Heating, Ventilating, and Air-Conditioning Strategies in Low-Load Homes

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2016-02-17

    "Modern, energy efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

  13. Ant-nest corrosion of copper tubing in air-conditioning units

    Directory of Open Access Journals (Sweden)

    Bastidas, D. M.

    2006-10-01

    Full Text Available Ant-nest corrosion is a specific type of premature failure (2-3 months of copper tubes used in air-conditioning units causing the loss of refrigerant liquid and the consequent environment pollution. It is known that attack requires the simultaneous presence of moisture, oxygen and a corrodent, usually an organic acid, such as formic, acetic, propionic or butyric acid or other volatile organic substances like methanol, ethanol, formaldehyde or acetoaldehyde. Approximately 10% of all premature failures of copper tubes used in the heating, ventilation and air-conditioning (HVAC industry are the result of ant-nest corrosion. This type of corrosion usually occurs in thin-wall copper pipes, especially when copper is de-sulphurised, and is known by several names: formicary corrosion, unusual corrosion, branched pits, pinhole corrosion, etc.

    Corrosión por “nido de hormigas” es un tipo específico de fallo prematuro (2-3 meses que tiene lugar en tubos de cobre utilizados en sistemas de aire acondicionado originando la pérdida de líquido refrigerante y la consecuente contaminación ambiental. Es conocido que este tipo de ataque requiere la presencia simultánea de humedad, oxígeno y un medio agresivo, habitualmente un ácido orgánico, como fórmico, acético  propiónico o butírico u otras sustancias orgánicas volátiles tales como metanol, etanol, formaldehido o acetoaldehido. Aproximadamente el 10% de los fallos prematuros en tubos de cobre utilizados en calefacción, ventilación y en la industria de aire acondicionado son el resultado de corrosión por nido de hormigas. Frecuentemente, este tipo de corrosión tiene lugar en tubos de cobre de pared delgada, especialmente cuando el cobre es del tipo desulfurizado, y se conoce con varios nombres: corrosión por ácido fórmico, corrosión no habitual, picaduras ramificadas, corrosión con forma de alfiler, etc.

  14. Experimental investigation on the photovoltaic-thermal solar heat pump air-conditioning system on water-heating mode

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Guiyin; Hu, Hainan; Liu, Xu [Department of Physics, Nanjing University, Nanjing 210093 (China)

    2010-09-15

    An experimental study on operation performance of photovoltaic-thermal solar heat pump air-conditioning system was conducted in this paper. The experimental system of photovoltaic-thermal solar heat pump air-conditioning system was set up. The performance parameters such as the evaporation pressure, the condensation pressure and the coefficient of performance (COP) of heat pump air-conditioning system, the water temperature and receiving heat capacity in water heater, the photovoltaic (PV) module temperature and the photovoltaic efficiency were investigated. The experimental results show that the mean photovoltaic efficiency of photovoltaic-thermal (PV/T) solar heat pump air-conditioning system reaches 10.4%, and can improve 23.8% in comparison with that of the conventional photovoltaic module, the mean COP of heat pump air-conditioning system may attain 2.88 and the water temperature in water heater can increase to 42 C. These results indicate that the photovoltaic-thermal solar heat pump air-conditioning system has better performances and can stably work. (author)

  15. Interaction of temperature, humidity, driver preferences, and refrigerant type on air conditioning compressor usage.

    Science.gov (United States)

    Levine, C; Younglove, T; Barth, M

    2000-10-01

    Recent studies have shown large increases in vehicle emissions when the air conditioner (AC) compressor is engaged. Factors that affect the compressor-on percentage can have a significant impact on vehicle emissions and can also lead to prediction errors in current emissions models if not accounted for properly. During 1996 and 1997, the University of California, Riverside, College of Engineering-Center for Environmental Research and Technology (CE-CERT) conducted a vehicle activity study for the California Air Resources Board (CARB) in the Sacramento, CA, region. The vehicles were randomly selected from all registered vehicles in the region. As part of this study, ten vehicles were instrumented to collect AC compressor on/off data on a second-by-second basis in the summer of 1997. Temperature and humidity data were obtained and averaged on an hourly basis. The ten drivers were asked to complete a short survey about AC operational preferences. This paper examines the effects of temperature, humidity, refrigerant type, and driver preferences on air conditioning compressor activity. Overall, AC was in use in 69.1% of the trips monitored. The compressor was on an average of 64% of the time during the trips. The personal preference settings had a significant effect on the AC compressor-on percentage but did not interact with temperature. The refrigerant types, however, exhibited a differential response across temperature, which may necessitate separate modeling of the R12 refrigerant-equipped vehicles from the R134A-equipped vehicles. It should be noted that some older vehicles do get retrofitted with new compressors that use R134A; however, none of the vehicles in this study had been retrofitted. PMID:11288304

  16. Variation of atmospheric air pollution under conditions of rapid economic change—Estonia 1994-1999

    Science.gov (United States)

    Kimmel, V.; Tammet, H.; Truuts, T.

    Estonia is an example of a country with economy in transition whose atmospheric air pollution has been remarkably influenced by economic changes. During the period of 1994-1999 GDP increased by one-fourth, while agricultural production, electricity and heat production dropped by one-sixths during the studied period. These processes are reflected in the quantity of emissions and structure of air pollution. The study is based on the measurements of concentrations of pollutants at six Estonian Euroairnet monitoring stations—at three sites in the capital city and at three sites in remote areas. The pollutants concerned are the first-priority pollutants in the European Union legislation—nitrogen oxides, SO 2, O 3, particulate matter, and additionally CO. The study reveals that concentrations of gaseous pollutants in Estonia remain within the EU limit values except for ozone in remote areas. The main trend during the studied period was a significant, up to several times, decrease in concentrations of SO 2 and CO while the decrease of nitrogen oxides was less remarkable. The paper propose ratio of NO x/SO 2 as an index describing increasing transport loads and drop in use of sulphur-rich fuels—thus of structure of economy. The annual variation of pollutants is explained by seasonal variations of anthropogenic activity in conditions where local fuels are widely used for heating during winter. Air pollution in Estonian rural stations mostly originated from transboundary fluxes. The 1-3 day delay of the weekly minimum of pollutant concentrations and the wind roses allow to conclude that essential part of pollutants is imported from West Europe.

  17. Variation of atmospheric air pollution under conditions of rapid economic change - Estonia 1994-1999

    Energy Technology Data Exchange (ETDEWEB)

    Kimmel, V.; Tammet, H. [University of Tartu (Estonia). Institute of Environmental Physics; Truuts, T. [Estonian Environmental Research Centre, Tallinn (Estonia)

    2002-09-01

    Estonia is an example of a country with economy in transition whose atmospheric air pollution has been remarkably influenced by economic changes. During the period of 1994-1999 GDP increased by one-fourth, while agricultural production, electricity and heat production dropped by one-sixths during the studied period. These processes are reflected in the quantity of emissions and structure of air pollution. The study is based on the measurements of concentrations of pollutants at six Estonian Euroairnet monitoring stations - at three sites in the capital city and at three sites in remote areas. The pollutants concerned are the first-priority pollutants in the European Union legislation-nitrogen oxides, SO{sub 2}, O{sub 3}, particulate matter, and additionally CO. The study reveals that concentrations of gaseous pollutants in Estonia remain within the EU limit values except for ozone in remote areas. The main trend during the studied period was a significant, up to several times, decrease in concentrations of SO{sub 2} and CO while the decrease of nitrogen oxides was less remarkable. The paper propose ratio of NO{sub x}/SO{sub 2} as an index describing increasing transport loads and drop in use of sulphur-rich fuels - thus of structure of economy. The annual variation of pollutants is explained by seasonal variations of anthropogenic activity in conditions where local fuels are widely used for heating during winter. Air pollution in Estonian rural stations mostly originated from transboundary fluxes. The 1-3 day delay of the weekly minimum of pollutant concentrations and the wind roses allow to conclude that essential part of pollutants is imported from West Europe. (author)

  18. High Efficiency Liquid-Desiccant Regenerator for Air Conditioning and Industrial Drying

    Energy Technology Data Exchange (ETDEWEB)

    Andrew Lowenstein

    2005-12-19

    Over 2 quads of fossil fuels are used each year for moisture removal. This includes industrial and agricultural processes where feedstocks and final products must be dried, as well as comfort conditioning of indoor spaces where the control of humidity is essential to maintaining healthy, productive and comfortable working conditions. Desiccants, materials that have a high affinity for water vapor, can greatly reduce energy use for both drying and dehumidification. An opportunity exists to greatly improve the competitiveness of advanced liquid-desiccant systems by increasing the efficiency of their regenerators. It is common practice within the chemical process industry to use multiple stage boilers to improve the efficiency of thermal separation processes. The energy needed to regenerate a liquid desiccant, which is a thermal separation process, can also be reduced by using a multiple stage boiler. In this project, a two-stage regenerator was developed in which the first stage is a boiler and the second stage is a scavenging-air regenerator. The only energy input to this regenerator is the natural gas that fires the boiler. The steam produced in the boiler provides the thermal energy to run the second-stage scavenging-air regenerator. This two-stage regenerator is referred to as a 1?-effect regenerator. A model of the high-temperature stage of a 1?-effect regenerator for liquid desiccants was designed, built and successfully tested. At nominal operating conditions (i.e., 2.35 gpm of 36% lithium chloride solution, 307,000 Btu/h firing rate), the boiler removed 153 lb/h of water from the desiccant at a gas-based efficiency of 52.9 % (which corresponds to a COP of 0.95 when a scavenging-air regenerator is added). The steam leaving the boiler, when condensed, had a solids concentration of less than 10 ppm. This low level of solids in the condensate places an upper bound of about 6 lb per year for desiccant loss from the regenerator. This low loss will not create

  19. Effectiveness and humidification capacity investigation of liquid-to-air membrane energy exchanger under low heat capacity ratios at winter air conditions

    Science.gov (United States)

    Kassai, Miklos

    2015-06-01

    In this research, a novel small-scale single-panel liquid-to-air membrane energy exchanger has been used to numerically investigate the effect of given number of heat transfer units (4.5), different cold inlet air temperature (1.7, 5.0, 10.0 °C) and different low heat capacity ratio (0.4, 0.5, 0.6, 0.7, 0.8, 0.9) on the steady-state performance of the energy exchanger. This small-scale energy exchanger represents the full-scale prototypes well, saving manufacturing costs and time. Lithium chloride is used as a salt solution in the system and the steady-state total effectiveness of the exchanger is evaluated for winter inlet air conditions. The results show that total effectiveness of the energy exchanger decreases with heat capacity ratio in the mentioned range. Maximum numerical total effectiveness of 97% is achieved for the energy exchanger. Increasing the heat capacity ratio values on given inlet air temperature, the humidification capacity of energy exhanger is also investigated in this paper. The humidification performance increases with heat capacity ratio. The highest humidification performance (4.53 g/kg) can be reached when inlet air temperature is 1.7 °C, and heat capacity ratio is 1.0 in winter inlet air conditions in the range of low heat capacity ratio.

  20. Air pollution and hospital admissions for respiratory conditions in Rome, Italy.

    Science.gov (United States)

    Fusco, D; Forastiere, F; Michelozzi, P; Spadea, T; Ostro, B; Arcà, M; Perucci, C A

    2001-06-01

    Most of the evidence regarding the association between particulate air pollution and emergency room visits or hospital admissions for respiratory conditions and asthma comes from the USA. European time-series analyses have suggested that gaseous air pollutants are important determinants of acute hospitalization for respiratory conditions, at least as important as particulate mass. The association between daily mean levels of suspended particles and gaseous pollutants (sulphur dioxide, nitrogen dioxide, carbon monoxide, ozone) was examined. The daily emergency hospital admissions for respiratory conditions in the metropolitan area of Rome during 1995-1997 were also recorded. Daily counts of hospital admissions for total respiratory conditions (43 admissions day(-1)), acute respiratory infections including pneumonia (18 day(-1)), chronic obstructive pulmonary disease (COPD) (13 day(-1)), and asthma (4.5 day(-1)) among residents of all ages and among children (0-14 yrs) were analysed. The generalized additive models included spline smooth functions of the day of study, mean temperature, mean humidity, influenza epidemics, and indicator variables for day of the week and holidays. Total respiratory admissions were significantly associated with same-day level of NO2 (2.5% increase per interquartile range (IQR) change, 22.3 microg x m(-3)) and CO (2.8% increase per IQR, 1.5 mg x m(-3)). No effect was found for particulate matter and SO2, whereas O3 was associated with admissions only among children (lag 1, 5.5% increase per IQR, 23.9 microg x m3). The effect of NO2 was stronger on acute respiratory infections (lag 0, 4.0% increase) and on asthma among children (lag 1, 10.7% increase). The admissions for all ages for asthma and COPD were associated only with same-day level of CO (5.5% and 4.3% increase, respectively). Multipollutant models confirmed the role of CO on all respiratory admissions, including asthma and COPD, and that of NO2 on acute respiratory infections

  1. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  2. Fuzzy logic controller implementation for a solar air-conditioning system

    International Nuclear Information System (INIS)

    The implementation of a variable structure fuzzy logic controller for a solar powered air conditioning system and its advantages are investigated in this paper. Two DC motors are used to drive the generator pump and the feed pump of the solar air-conditioner. Two different control schemes for the DC motors rotational speed adjustment are implemented and tested: the first one is a pure fuzzy controller, its output being the control signal for the DC motor driver. A 7 x 7 fuzzy matrix assigns the controller output with respect to the error value and the derivative of the error. The second scheme is a two-level controller. The lower level is a conventional PID controller, and the higher level is a fuzzy controller acting over the parameters of the low level controller. Step response of the two control loops are presented as experimental results. The contribution of this design is that in the control system, the fuzzy logic is implemented through software in a common, inexpensive, 16-bit microcontroller, which does not have special abilities for fuzzy control

  3. The performance of a mobile air conditioning system with a water cooled condenser

    Science.gov (United States)

    Di Battista, Davide; Cipollone, Roberto

    2015-11-01

    Vehicle technological evolution lived, in recent years, a strong acceleration due to the increased awareness of environmental issues related to pollutants and climate altering emissions. This resulted in a series of international regulations on automotive sector which put technical challenges that must consider the engine and the vehicle as a global system, in order to improve the overall efficiency of the system. The air conditioning system of the cabin, for instance, is the one of the most important auxiliaries in a vehicle and requires significant powers. Its performances can be significantly improved if it is integrated within the engine cooling circuit, eventually modified with more temperature levels. In this paper, the Authors present a mathematical model of the A/C system, starting from its single components: compressors, condenser, flush valve and evaporator and a comparison between different refrigerant fluid. In particular, it is introduced the opportunity to have an A/C condenser cooled by a water circuit instead of the external air linked to the vehicle speed, as in the actual traditional configuration. The A/C condenser, in fact, could be housed on a low temperature water circuit, reducing the condensing temperature of the refrigeration cycle with a considerable efficiency increase.

  4. Removal of polycyclic aromatic hydrocarbons (PAHs) from industrial sludges in the ambient air conditions: automotive industry.

    Science.gov (United States)

    Karaca, Gizem; Tasdemir, Yucel

    2013-01-01

    Removal of polycyclic aromatic hydrocarbons (PAHs) existed in automotive industry treatment sludge was examined by considering the effects of temperature, UV, titanium dioxide (TiO2) and diethyl amine (DEA) in different dosages (i.e., 5% and 20%) in this study. Application of TiO2 and DEA to the sludge samples in ambient environment was studied. Ten PAH (Σ10 PAH) compounds were targeted and their average value in the sludge was found to be 4480 ± 1450 ng/g dry matter (DM). Total PAH content of the sludge was reduced by 25% in the ambient air environment. Meteorological conditions, atmospheric deposition, evaporation and sunlight irradiation played an effective role in the variations in PAH levels during the tests carried out in ambient air environment. Moreover, it was observed that when the ring numbers of PAHs increased, their removal rates also increased. Total PAH level did not change with the addition of 5% DEA and only 10% decreased with 5% TiO2 addition. PAH removal ratios were 8% and 32% when DEA (20%) and TiO2 (20%) were added, respectively. It was concluded that DEA was a weak photo-sensitizer yet TiO2 was effective only at 20% dosage. PMID:23485234

  5. Analysis of the Impact of Urban Microclimate on Air Conditioning Load Control

    Directory of Open Access Journals (Sweden)

    Hu Xiaoqing

    2016-01-01

    Full Text Available Due to the presence of urban heat island effect (UHIE, high humidity and other urban microclimate, temperature of city central area rises. This causes that the actual air-conditioning energy consumption (ACEC in the urban central area is much higher than that in the suburbs. Load control of air-conditioners (ACs is considered to be equivalent to a power plant of the same capacity, and it can greatly reduce the system pressure to peak load shift. In this paper, a simplified second order transfer function control model of ACs is presented, and its parameters will be influenced by the ambient temperature and urban microclimate. The temperature is obtained by using the temperature inversion algorithm of the heat island effect. Then, the heat index is calculated by combining temperature and humidity. The ambient temperature index of urban central area is modified based on the above microclimate, and the second order linear time invariant model of aggregated ACs is upgraded to the linear time varying model. Furthermore, the consequent parameter changes of the second order transfer function model are studied and the influence of urban microclimate on AC load control is analyzed. The proposed method is verified on numerical examples

  6. The effect of the atmospheric condition on the extensive air shower analysis at the Telescope Array experiment

    International Nuclear Information System (INIS)

    The accuracies in determination of air shower parameters such as longitudinal profiles or primary energies with the fluorescence detection technique are strongly dependent on atmospheric conditions of the molecular and aerosol components. Moreover, air fluorescence photon yield depends on the atmospheric density, and the transparency of the air for fluorescence photons depends on the atmospheric conditions from EAS to FDs. In this paper, we describe the atmospheric monitoring system in the Telescope Array (TA experiment), and the impact of the atmospheric conditions in air shower reconstructions. The systematic uncertainties of the determination of the primary cosmic ray energies and of the measurement of depth of maximum development (Xmax) of EASs due to atmospheric variance are evaluated by Monte Carlo simulation.

  7. A review on the recent development of solar absorption and vapour compression based hybrid air conditioning with low temperature storage

    Directory of Open Access Journals (Sweden)

    Noor D. N.

    2016-01-01

    Full Text Available Conventional air conditioners or vapour compression systems are main contributors to energy consumption in modern buildings. There are common environmental issues emanating from vapour compression system such as greenhouse gas emission and heat wastage. These problems can be reduced by adaptation of solar energy components to vapour compression system. However, intermittence input of daily solar radiation was the main issue of solar energy system. This paper presents the recent studies on hybrid air conditioning system. In addition, the basic vapour compression system and components involved in the solar air conditioning system are discussed. Introduction of low temperature storage can be an interactive solution and improved economically which portray different modes of operating strategies. Yet, very few studies have examined on optimal operating strategies of the hybrid system. Finally, the findings of this review will help suggest optimization of solar absorption and vapour compression based hybrid air conditioning system for future work while considering both economic and environmental factors.

  8. Development of High Speed Inverter Rotary Compressor for the Air-conditioning System

    Science.gov (United States)

    Kang, Seoung-Min; Yang, Eun-soo; Shin, Jin-Ung; Park, Joon-Hong; Lee, Se-Dong; Ha, Jong-Hun; Son, Young-Boo; Lee, Byeong-Chul

    2015-08-01

    In order to meet the various operating loads of an air-conditioning system, an inverter compressor with a wide operational range is necessary. One of the ways to achieve a wide operation range is to drive a small capacity compressor at high speed. Moreover, it is possible to maximize the efficiency in part-load operation condition close to actual operating conditions and to reduce the cost by compact design of a small capacity compressor. In addition, the shortage of maximum capacity, due to the small rated capacity, is covered through high speed operation. However, in general, if the compressor operates at high speed, problems occurs such as reduced efficiency due to friction, increased noise, increased amount of oil discharge and decreased durability of the main components. In order to solve these problems the following have been investigated: optimized dimension parameters of the compression chamber, enhanced shaft design and the structure for the reduction of oil discharge and noise at high speed operation. Finally the high speed inverter rotary compressor with high efficiency and more compact size has been developed as compared with the conventional rotary compressor.

  9. Applicability of thermal energy storage recycled ceramics to high temperature and compressed air operating conditions

    International Nuclear Information System (INIS)

    Highlights: • ACW ceramics have been successfully tested under ACAES operating conditions. • ACW ceramics have been successfully tested under gas turbine based CSP conditions. • Under 600 °C-30 bars of air, ACW ceramics Cp is slightly lowered by 5%. • Thermal conductivity of ACW ceramics is advantageously enhanced by 30%. - Abstract: Recycled ceramics made of inertized asbestos containing wastes have been submitted to high pressure/temperature cycling tests in the operating range of ACAES and CSP applications. Ten successive cycles between room conditions and 610 °C/30 bars for a cumulated duration of 2500 h lead to a validation of the ability of the material to resist to those constrains. The Wollastonite/Augite initial structure is gradually transformed in a unique Augite containing material. While mechanical parameters and density are unchanged, thermal capacity is reduced by 5% and thermal conductivity increased by 30%. This last result offers an advantageous way to enhance the thermal conductivity of those recycled ceramics, a key parameter to control the charge/discharge power in TES systems

  10. Introduction Analysis of Refrigerating and Air-Conditioning Technologies in Micro Grid Type Food Industrial Park

    Science.gov (United States)

    Shimazaki, Yoichi

    The aim of this study was to evaluate the refrigerating and air-conditioning technologies in cases of introducing both cogeneration system and energy network in food industrial park. The energy data of 14 factories were classified into steam, hot water, heating, cooling, refrigerating, freezing and electric power by interviews. The author developed a micro grid model based on linear programming so as to minimize the total system costs. The industrial park was divided into the 2,500 square meter mesh in order to take steam transport into consideration. Four cases were investigated. It was found that the electric power driven freezer was introduced compared with the ammonia absorption freezer. The ammonia absorption freezer was introduced in the factory that there is a little steam demand and large freezing demand at the same time.

  11. Geomagnetic effects on cosmic ray propagation under different conditions for Buenos Aires and Marambio, Argentina

    CERN Document Server

    Masías-Meza, Jimmy J

    2014-01-01

    The geomagnetic field (Bgeo) sets a lower cutoff rigidity (Rc) to the entry of cosmic particles to Earth which depends on the geomagnetic activity. From numerical simulations of the trajectory of a proton using different models for Bgeo (performed with the MAGCOS code), we use backtracking to analyze particles arriving at the location of two nodes of the net LAGO (Large Aperture Gamma ray burst Observatory) that will be built in the near future: Buenos Aires and Marambio (Antarctica), Argentina. We determine the asymptotic trajectories and the values of Rc for different incidence directions, for each node. Simulations were done using several models for Bgeo that emulate different geomagnetic conditions. The presented results will help to make analysis of future observations of the flux of cosmic rays done at these two LAGO nodes.

  12. Study on air formation to ground attack-defends decision making in fuzzy condition

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    With the development of modern military technology, uncertain decision-making problems become more and more exigent to be solved in military command and control. Based on game theory, and taking air formation to ground attack-defends campaign as the background, this paper established an opposed dynamic decision-making model. As to the problems in military decision-making in fuzzy condition in uncertainty, this paper put forward a fuzzy-influence-factor, which reflects the fuzzy influence on battle units, and establishes a fuzzy opposed decision-making model in anticipant value and in correlative chance way farther to get strategy equilibrium. It can be seen from the simulating results that the model disposes the fuzzy status in battlefield reasonably, analyzes the fighting results objectively, and offers a powerful decision-making support for military operation. The method is practically and effectively.

  13. Comparative study of air conditioning systems with vapor compression chillers using the concept of green buildings

    Directory of Open Access Journals (Sweden)

    Gutenberg da Silva Pereira

    2015-10-01

    Full Text Available This paper sets out to compare two different cooling systems that use vapor compression chillers for air conditioning environments. It was proposed to compare different operations in isolated and combined action operations. These operations are evaluated in the concepts of green buildings. A mathematical model was developed based on the principles of mass and energy conservation and complemented by various functions so as to determine the thermophysical properties and efficiencies of the compressors. The equations of the model were solved by the EES (Engineering Equation Solver program. The model evaluates the influence of the main HVAC operating parameters of the chilled water system when operating under three different configurations. The results showed that the system with a differentiated compression presents a COP equal to that of the system with screw chillers in the range  0-300 RTs, and a COP hat is on average 9% higher in the range 400-800 RTs.

  14. Preventive maintenance plan of the air-conditioning duct using the ACM-sensor

    International Nuclear Information System (INIS)

    Air-conditioning duct is difficult to predict the date to occur of corrosion such as affect the function. Therefore, the current conservation method is mostly corrective maintenance. Therefore, we used the test pieces of six types and ACM-sensor in order to solve the corrosion speed from corrosion environment and relationship of corrosion quantity of test pieces. In addition, was used the duct molded articles various in order to check the corrosion degree of when processed the duct. As a result, we were selected crust body constituting a duct and optimal combination of the flange by solve the corrosion speed of the test pieces various. Thus, it performs preventive disposal before to occur of corrosion such as affect the function by predicting the duct life from corrosion speed, and lead to stability and safe operating by appropriate maintenance of equipment. (author)

  15. Parametric study of an energy efficient air conditioning system using liquid desiccant

    Energy Technology Data Exchange (ETDEWEB)

    Kinsara, Adnan A.; Al-Rabghi, Omar M. [King Abdulaziz Univ., Mechanical Engineering Dept., Jeddah (Saudi Arabia); Elsayed, Moustafa M. [Kuwait Univ., Mechanical Engineering Dept., Safat (Kuwait)

    1998-05-01

    Liquid desiccant can be used effectively to reduce energy consumed in air conditioning (AC). Unlike conventional AC, the latent part of the cooling load is overcome using liquid desiccant. In a previous article, an energy efficient system utilizing CaCl{sub 2} as liquid desiccant was proposed. This study is an extension of that work. The effect of key variables on the performance of the proposed system is undertaken. The inlet temperature of the liquid desiccant to the dehumidifier, space sensible heat ratio, and heat exchanger effectivenesses are the variables studied. Variations of these parameters and their effects on system performance are presented. Good system performance and energy saving could be achieved if proper values of these variables are selected. (Author)

  16. Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application

    Directory of Open Access Journals (Sweden)

    Mohammed A. Atiya

    2014-09-01

    Full Text Available This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP and the coefficient of performance (COP are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

  17. Japanese power electronics inverter technology and its impact on the American air conditioning industry

    Energy Technology Data Exchange (ETDEWEB)

    Ushimaru, Kenji.

    1990-08-01

    Since 1983, technological advances and market growth of inverter- driven variable-speed heat pumps in Japan have been dramatic. The high level of market penetration was promoted by a combination of political, economic, and trade policies in Japan. A unique environment was created in which the leading domestic industries-- microprocessor manufacturing, compressors for air conditioning and refrigerators, and power electronic devices--were able to direct the development and market success of inverter-driven heat pumps. As a result, leading US variable-speed heat pump manufacturers should expect a challenge from the Japanese producers of power devices and microprocessors. Because of the vertically-integrated production structure in Japan, in contrast to the out-sourcing culture of the United States, price competition at the component level (such as inverters, sensors, and controls) may impact the structure of the industry more severely than final product sales. 54 refs., 47 figs., 1 tab.

  18. Distributed Air-Conditioning Energy Management System within the Smart Grid Context

    Institute of Scientific and Technical Information of China (English)

    A.H.Osman; A.R.Al-Ali; Haroon Khalil; Kiran Prem; Mursalin Haider; Mishal Eskander

    2014-01-01

    Air-conditioning (AC) systems are the major energy consumption units in residential and commercial buildings. In the context of smart grid, optimizing AC operations leads to substantial saving in energy consumption, reducing the consumer’s bill and contributing to the environment by minimizing carbon emissions from generating stations. This paper presents a distributed AC energy management system for buildings by using networked master-slaves controller architecture. The proposed system was designed, simulated, and experimentally tested by using real AC units in a students’ residence hall. Based on the students’ class schedules, several operational scenarios were implemented and tested. The proposed system implementation leads to a 40% to 60% saving of the consumed energy by the tested units. The same energy management scheme can be applied and implemented in other commercial and residential buildings.

  19. Development of air conditioning technologies to reduce CO2 emissions in the commercial sector

    Directory of Open Access Journals (Sweden)

    Yoshida Yukiko

    2006-10-01

    Full Text Available Abstract Background Architectural methods that take into account global environmental conservation generally concentrate on mitigating the heat load of buildings. Here, we evaluate the reduction of carbon dioxide (CO2 emissions that can be achieved by improving heating, ventilating, and air conditioning (HVAC technologies. Results The Climate Change Research Hall (CCRH of the National Institute for Environmental Studies (NIES is used as a case study. CCRH was built in line with the "Green Government Buildings" program of the Government Buildings Department at the Ministry of Land, Infrastructure and Transport in Japan. We have assessed the technology used in this building, and found that there is a possibility to reduce energy consumption in the HVAC system by 30%. Conclusion Saving energy reduces CO2 emissions in the commercial sector, although emission factors depend on the country or region. Consequently, energy savings potential may serve as a criterion in selecting HVAC technologies with respect to emission reduction targets.

  20. Thermal design of a modern, air-conditioned, single-floor, solar-powered desert house

    KAUST Repository

    Serag-Eldin, M. A.

    2011-12-01

    The paper presents a thermal analysis of a single-floor, solar-powered desert house. The house is air-conditioned and provides all modern comforts and facilities. Electrical power, which drives the entire energy system, is generated by roof-mounted photovoltaic modules. The modules are fixed on special cradles which fold at night to expose the roof to the night sky, thereby enhancing night-time cooling, which is substantial in the desert environment. A detailed dynamic heat transfer analysis is conducted for the building envelope, coupled with a solar radiation model. Application to a typical Middle-Eastern desert site reveals that indeed such a design is feasible with present-day technology; and should be even more attractive with future advances in technology. © 2011 Copyright Taylor and Francis Group, LLC.

  1. Influence of Urban Microclimate on Air-Conditioning Energy Needs and Indoor Thermal Comfort in Houses

    Directory of Open Access Journals (Sweden)

    Feng-Chi Liao

    2015-01-01

    Full Text Available A long-term climate measurement was implemented in the third largest city of Taiwan, for the check of accuracy of morphing approach on generating the hourly data of urban local climate. Based on observed and morphed meteorological data, building energy simulation software EnergyPlus was used to simulate the cooling energy consumption of an air-conditioned typical flat and the thermal comfort level of a naturally ventilated typical flat. The simulated results were used to quantitatively discuss the effect of urban microclimate on the energy consumption as well as thermal comfort of residential buildings. The findings of this study can serve as a reference for city planning and energy management divisions to study urban sustainability strategies in the future.

  2. HVAC (heating, ventilation, air conditioning) literature in Japan: A critical review

    Energy Technology Data Exchange (ETDEWEB)

    Hane, G.J.

    1988-02-01

    Japanese businessmen in the heating, ventilation, air conditioning, and refrigeration (HVACandR) industry consider the monitoring of technical and market developments in the United States to be a normal part of their business. In contrast, efforts by US businessmen to monitor Japanese HVAC and R developments are poorly developed. To begin to redress this imbalance, this report establishes the groundwork for a more effective system for use in monitoring Japanese HVAC and R literature. Discussions of a review of the principal HVAC and R publications in Japan and descriptions of the type of information contained in each of those publications are included in this report. Since the Japanese HVAC and R literature is abundant, this report also provides practical suggestions on how a researcher or research manager can limit the monitoring effort to the publications and type of information that would most likely be of greatest value.

  3. Selection of Weather Parameters for Air-Conditioning System Design for Buildings with Long Thermal Lag

    Institute of Scientific and Technical Information of China (English)

    GE Lian-feng; LEI Ming; CHEN You-ming

    2009-01-01

    Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-con-ditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irra-diance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the de-sign weather data for the three different constructions is not kept constant.

  4. Study and Development of an Air Conditioning System Operating on a Magnetic Heat Pump Cycle

    Science.gov (United States)

    Wang, Pao-Lien

    1991-01-01

    This report describes the design of a laboratory scale demonstration prototype of an air conditioning system operating on a magnetic heat pump cycle. Design parameters were selected through studies performed by a Kennedy Space Center (KSC) System Simulation Computer Model. The heat pump consists of a rotor turning through four magnetic fields that are created by permanent magnets. Gadolinium was selected as the working material for this demonstration prototype. The rotor was designed to be constructed of flat parallel disks of gadolinium with very little space in between. The rotor rotates in an aluminum housing. The laboratory scale demonstration prototype is designed to provide a theoretical Carnot Cycle efficiency of 62 percent and a Coefficient of Performance of 16.55.

  5. Evaluation Framework and Analyses for Thermal Energy Storage Integrated with Packaged Air Conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Kung, F.; Deru, M.; Bonnema, E.

    2013-10-01

    Few third-party guidance documents or tools are available for evaluating thermal energy storage (TES) integrated with packaged air conditioning (AC), as this type of TES is relatively new compared to TES integrated with chillers or hot water systems. To address this gap, researchers at the National Renewable Energy Laboratory conducted a project to improve the ability of potential technology adopters to evaluate TES technologies. Major project outcomes included: development of an evaluation framework to describe key metrics, methodologies, and issues to consider when assessing the performance of TES systems integrated with packaged AC; application of multiple concepts from the evaluation framework to analyze performance data from four demonstration sites; and production of a new simulation capability that enables modeling of TES integrated with packaged AC in EnergyPlus. This report includes the evaluation framework and analysis results from the project.

  6. Experimental evaluation of a direct air-cooled lithium bromide-water absorption prototype for solar air conditioning

    OpenAIRE

    González-Gil, A.; Izquierdo, M.; Marcos, J.D.; Palacios, E.

    2011-01-01

    Abstract A new direct air-cooled single-effect LiBr-H2O absorption prototype is described and proposed for use in solar cooling. As distinguishing aspects, it presents: an adiabatic absorber using flat-fan sheets; an air-cooling system that directly refrigerates both the condenser and the absorber and; the possibility of being operated also as a double-effect unit. A solar facility comprising a 48m2 field of flat-plate collectors was used to test the single-effect operation mode of...

  7. A Mobile Air Conditioning System Operated by the Engine Waste Heat

    Energy Technology Data Exchange (ETDEWEB)

    Magnetto, D. [Centro Ricerche FIAT, Turin (Italy); De Boer, R. [ECN Efficiency and Infrastructure, Petten (Netherlands); Taklanti, A. [Valeo Systemes Thermiques SAS, Paris (France)

    2011-04-12

    This paper describes the development of a Mobile Air Conditioning (MAC) system with a very small impact on the environment. The system based on adsorption cooling is powered by the waste heat recovered from the engine coolant. The advantages of such a system are: a drastic reduction of the fuel overconsumption and the CO2 emission associated to the MAC usage, and the use of water as the refrigerant, which is a no Global Warming Potential (GWP) fluid compliant with the new EU regulation and naturally available. In addition the system being based on thermal compression and not on mechanical compression, is decoupled from the engine operation and has no impact on the vehicle handling. Finally, coupled with a small fuel burner or with a solar panel it can provide air conditioning when the vehicle engine is stop. Thus the system can provide the cabin preconditioning and allows the cabin cooling for those vehicles which are also used for rest or sleeping (truck, camper). The core of the system is an adsorption chiller that has been designed, manufactured and tested at first at the ECN laboratory. It produces 2 kW of chilling power with a COP of 0,4. The on board overall MAC system has been designed, manufactured and installed on a Fiat Grande Punto at CRF. The tests demonstrate the potential of such device to replace conventional vapor compression system. Following this experimental work a system redesign and car integration study was done and showed the potential to further reduce the volume and weight of the adsorption cooling system to the extent that the system can be integrated fully in the engine compartment.

  8. Performance evaluation of solar-assisted air-conditioning system with chilled water storage (CIESOL building)

    International Nuclear Information System (INIS)

    Highlights: ► We present a new solar-assisted air-conditioning system’s operation sequence. ► This mode considers the chilled water tanks action with variable-speed pump. ► It permits to save about 20% and 30% of energy and water consumption, respectively. ► It allows storing the excess cooling capacity of the absorption chiller. ► It prevents the sudden start/stop (on/off cycles) of the absorption chiller. - Abstract: This study presents the performance of solar-assisted air-conditioning system with two chilled water storage tanks installed in the Solar Energy Research Center building. The system consists mainly of solar collectors’ array, a hot-water driven absorption chiller, a cooling tower, two hot storage tanks, an auxiliary heater as well as two chilled storage tanks. The chilled water storage tank circuit was further investigated in order to find the optimum solar system’s operation sequence while providing the best energy performance. Firstly, we carried out a study about the dynamics of building’s cooling load and the necessity of the integration of chilled water storage tanks to solar system. Subsequently, the new system’s operation mode was proposed to reduce the energy consumption. The results demonstrate that we can save about 20% of the total energy consumption and about 30% of water consumption applying the new operation sequence, which takes into account the chilled water tanks action. Moreover, it was demonstrated that the integration of chilled water storage tanks allows to reduce the sudden absorption chiller on/off cycles, thereby improving the efficiency of the solar-assisted system.

  9. Emissions of halocarbons from mobile vehicle air conditioning system in Hong Kong

    Energy Technology Data Exchange (ETDEWEB)

    Yan, H.H.; Guo, H., E-mail: ceguohai@polyu.edu.hk; Ou, J.M.

    2014-08-15

    Highlights: • Halocarbon emissions from MVACS were characterized using bottom up approach. • Quantification of emission inventory was revealed using AUV Tools. • Potential emission reduction was estimated under 3 possible mitigation scenarios. • The results are useful for the policy makers to formulate and implement future phase-out schedule. - Abstract: During the implementation of Montreal Protocol, emission inventories of halocarbons in different sectors at regional scale are fundamental to the formulation of relevant management strategy and inspection of the implementation efficiency. This study investigated the emission profile of halocarbons used in the mobile vehicle air conditioning system, the leading sector of refrigeration industry in terms of the refrigerant bank, market and emission, in the Hong Kong Special Administrative Region, using a bottom-up approach developed by 2006 IPCC Good Practice Guidance. The results showed that emissions of CFC-12 peaked at 53 tons ODP (Ozone Depletion Potential) in 1992 and then gradually diminished, whereas HFC-134a presented an increasing emission trend since 1990s and the emissions of HFC-134a reached 65,000 tons CO{sub 2}-equivelant (CO{sub 2}-eq) by the end of 2011. Uncertainty analysis revealed relatively high levels of uncertainties for special-purpose vehicles and government vehicles. Moreover, greenhouse gas (GHG) abatements under different scenarios indicated that potential emission reduction of HFC-134a ranged from 4.1 to 8.4 × 10{sup 5} tons CO{sub 2}-eq. The findings in this study advance our knowledge of halocarbon emissions from mobile vehicle air conditioning system in Hong Kong.

  10. Changes in the blood parameters of an air-breathing fish during different respiratory conditions.

    Science.gov (United States)

    Singh, B R; Thakur, R N; Yadav, A N

    1976-01-01

    Some of the blood parameters recorded in an air-breathing eel, Amphipnous cuchia under normal respiratory condition during non-breeding period (September-April) are haemoglobin (Hb) concentration 19.26%, haematocrit value 56.16%, RBC number 1.71 million/mm3, RBC size 18.86 X 9.70 mum, mean corpuscular haemoglobin (MCH) 113.4 ng, mean corpuscular haemoglobin concentration (MCHC) 34.2%, blood sugar 77 mg% and ascorbic acid 0.435 mg%. The higher concentration of haemoglobin (19.26%) appears to be related to its obligatory air breathing habit and habitat in a water of low oxygen content. Though a definite trend of increase in the haemoglobin and haematocrit concentration with an increase in the body weight of the fish was lacking, variations were clearly marked related to intrinsic activity of the fish connected with different respiratory conditions. Asphyxiation in a submerged but continuous flow of water (liter/h) for 5 1/2 h resulted in an increase in the above-mentioned parameters to an appreciable extent. These increases were 0.23 million/mm3 in the number of erythrocytes, 6.16% in haemoglobin concentration, 10% in haematocrit value, 20% in blood sugar and 35% in ascorbic acid content. The mean corpuscular haemoglobin showed a decline of 6.2%. Exclusive aerial breathing for 5 1/2 h also caused 7.4% increase in haemoglobin concentration, 9.4% in haematocrit value, 0.14 million/mm3 in RBC number, 20% in blood sugar level, 9% in ascorbic acid content but almost no change in mean corpuscular haemoglobin. The average surface area for diffusion of gases appeared to have reduced by 6.8 mum2 per RBC. PMID:61915

  11. Disease relapses in multiple sclerosis can be influenced by air pollution and climate seasonal conditions

    Directory of Open Access Journals (Sweden)

    Vojinović Slobodan

    2015-01-01

    Full Text Available Background/Aim. Environmental factors may influence the disease activity in patients with relapsing-remitting multiple sclerosis (MS. The aim of this study was to evaluate the influence of air pollution and seasonal climate factors of any on number of relapses in MS patients during a consecutive 5 years of observation. Methods. We retrospectively analyzed data of MS patients from the town of Niš, hospitalized at the Clinic of Neurology, Clinical Center Niš, Serbia, from 2005 to 2009. Climate data: mean daily sun shining; mean monthly sun shining, mean whole daily cloudiness, daily cloudiness at 7 a.m, 2 p.m. and 9 p.m. and air pollution expressed by NSR (New Source Review were obtained from the Meteorology Observatory Niš. Results. During a 5-year of observation there were 260 relapses in 101 MS patients. The number of relapses showed a significantly negative correlation with the number of days with NSR < 2 (ρ = -0.31; p < 0.01 and a positive correlation with the mean whole daily cloudiness (p < 0.05, mean daily cloudiness at 7 a.m. (p < 0.05 and 2 p.m. (p < 0.01. We found a significantly positive correlation (p < 0.05 between the reduced number of relapses during the period of high vitamin D season, i.e. July-October. There was a statistically significant increase (p < 0.01 of the number of relapses during spring (ґ = 6.53; SD = 3.98 compared to the other three seasons. The joint presence of lower number of days with NSR < 2 during low vitamin D season (January-April correlated with a statistically significant increase of the number of relapses in MS patients (F = 5.06, p < 0.01. Conclusion. The obtained results confirmed the influence of air pollution and climate seasonal conditions on disease relapses in MS patients based on a long-term observation. Lower numbers of days with low air pollution during the periods with low vitamin D (January-April, especially with increased cloudiness at 2 p.m, induce a higher risk of MS relapses in

  12. 40 CFR 86.162-00 - Approval of alternative air conditioning test simulations and descriptions of AC1 and AC2.

    Science.gov (United States)

    2010-07-01

    ... Procedures § 86.162-00 Approval of alternative air conditioning test simulations and descriptions of AC1 and AC2. The alternative air conditioning test procedures AC1 and AC2 are approved by the Administrator... requirements of paragraph (a) of this section and meet the requirements of § 86.163-00. Air conditioning...

  13. A study of energy use for ventilation and air-conditioning systems in Hong Kong

    Science.gov (United States)

    Yu, Chung Hoi Philip

    Most of the local modern buildings are high-rise with enclosed structure. Mechanical ventilation and air conditioning (MVAC) systems are installed for thermal comfort. Various types of MVAC systems found in Hong Kong were critically reviewed with comments on their characteristics in energy efficiency as well as application. The major design considerations were also discussed. Besides MVAC, other energy-consuming components in commercial buildings were also identified, such as lighting, lifts and escalators, office equipment, information technology facilities, etc. A practical approach has been adopted throughout this study in order that the end results will have pragmatic value to the heating, ventilating and air-conditioning (HVAC) industry in Hong Kong. Indoor Air Quality (IAQ) has become a major issue in commercial buildings worldwide including Hong Kong. Ventilation rate is no doubt a critical element in the design of HVAC systems, which can be realized more obviously in railway train compartments where the carbon dioxide level will be built up quickly when the compartments are crowded during rush hours. A study was carried out based on a simplified model using a train compartment that is equipped with an MVAC system. Overall Thermal Transfer Value (OTTV) is a single-value parameter for controlling building energy use and is relatively simple to implement legislatively. The local government has taken a first step in reacting to the worldwide concern of energy conservation and environmental protection since 1995. Different methods of OTTV calculation were studied and the computation results were compared. It gives a clear picture of the advantages and limitations for each method to the building designers. However, due to the limitations of using OTTV as the only parameter for building energy control, some new approaches to a total control of building energy use were discussed and they might be considered for future revision of the building energy codes in Hong

  14. Improving design factors of air diffuser systems based on field conditions of dam reservoirs: CFD simulation approach.

    Science.gov (United States)

    Shin, Sangmin; Lee, Seungjae; Lee, Sangeun; Yum, Kyungtaek; Park, Heekyung

    2012-01-01

    This study aims to improve the design factors of air diffuser systems that have been analyzed in laboratory experiments, with consideration of the field conditions of dam reservoirs. In this study, the destratification number (D(N)), destratification radius, and efficiency are considered as design factors. The computational fluid dynamics (CFD) simulation experiment is performed in diverse field conditions in order to analyze these factors. The results illustrate the wider range of D(N) values in field conditions and the relationship of the destratification radius and efficiency to D(N). The results can lead to better performance of air diffuser systems and water quality management in dam reservoir sites. PMID:22678200

  15. Phase equilibrium condition measurements in nitrogen and air clathrate hydrate forming systems at temperatures below freezing point of water

    International Nuclear Information System (INIS)

    Highlights: • Phase equilibrium conditions in the nitrogen and modelled air hydrate forming systems are measured. • Measurements are conducted at temperatures below the freezing point of water. • Results have relevance to the air hydrate formation in the ice sheets. • Measured data are quantitatively compared with the previously reported values. • Range of the equilibrium measurements was from (242 to 268) K. -- Abstract: Contained in this paper are the three phase equilibrium conditions of the (ice + clathrate hydrate + guest-rich) vapour in the (nitrogen + water) and the modelled (air + water) systems at temperatures below the freezing point of water. The precise determination of the equilibrium conditions in those systems are of importance for the analysis of the past climate change using the cored samples from the ice sheets at Antarctica and Greenland because the air hydrates keep the ancient climate signals. The mole ratio of the modelled air composed of nitrogen and oxygen is 0.790:0.210. The equilibrium conditions were measured by the batch, isochoric procedure. The temperature range of the measurements in the nitrogen hydrate forming system is (244.05 < T < 266.55) K and the corresponding equilibrium pressure range is (7.151 < p < 12.613) MPa. The temperature range of the measurements in the modelled air hydrate forming system is (242.55 < T < 267.85) K, and the corresponding equilibrium pressure range is (6.294 < p < 12.144) MPa. The data obtained quantitatively compared with the previously reported data

  16. Comparison of Fuel-Nox Formation Characteristics in Conventional Air and Oxy fuel Combustion Conditions

    International Nuclear Information System (INIS)

    Nitric oxide (NOx) formation characteristics in non-premixed diffusion flames of methane fuels have been investigated experimentally and numerically by adding 10% ammonia to the fuel stream, according to the variation of the oxygen ratio in the oxidizer with oxygen/carbon dioxide and oxygen/nitrogen mixtures. In an experiment of co flow jet flames, in the case of an oxidizer with oxygen/carbon dioxide, the NOx emission increased slightly as the oxygen ratio increased. On the other hand, in case of an oxygen/nitrogen oxidizer, the NOx emission was the maximum at an oxygen ratio of 0.7, and it exhibited non-monotonic behavior according to the oxygen ratio. Consequently, the NOx emission in the condition of oxy fuel combustion was overestimated as compared to that in the condition of conventional air combustion. To elucidate the characteristics of NOx formation for various oxidizer compositions, 1a and 2a numerical simulations have been conducted by adopting one kinetic mechanism. The result of 2 simulation for an oxidizer with oxygen/nitrogen well predicted the trend of experimentally measured NOx emissions

  17. Comparison of Fuel-Nox Formation Characteristics in Conventional Air and Oxy fuel Combustion Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Mino [Kyungwon Engineering and Communication, Seongnam (Korea, Republic of); Park, Kweon Ha [Korea Maritime Univ., Busan (Korea, Republic of); Choi, Byung Chul [Korean Register of Shipping, Busan (Korea, Republic of)

    2013-05-15

    Nitric oxide (NO{sub x}) formation characteristics in non-premixed diffusion flames of methane fuels have been investigated experimentally and numerically by adding 10% ammonia to the fuel stream, according to the variation of the oxygen ratio in the oxidizer with oxygen/carbon dioxide and oxygen/nitrogen mixtures. In an experiment of co flow jet flames, in the case of an oxidizer with oxygen/carbon dioxide, the NO{sub x} emission increased slightly as the oxygen ratio increased. On the other hand, in case of an oxygen/nitrogen oxidizer, the NO{sub x} emission was the maximum at an oxygen ratio of 0.7, and it exhibited non-monotonic behavior according to the oxygen ratio. Consequently, the NO{sub x} emission in the condition of oxy fuel combustion was overestimated as compared to that in the condition of conventional air combustion. To elucidate the characteristics of NO{sub x} formation for various oxidizer compositions, 1a and 2a numerical simulations have been conducted by adopting one kinetic mechanism. The result of 2 simulation for an oxidizer with oxygen/nitrogen well predicted the trend of experimentally measured NO{sub x} emissions.

  18. Simulating The Air-Condition Controlling In Operating Room And Improvement

    Directory of Open Access Journals (Sweden)

    Fereshteh Mohammadi

    2012-06-01

    Full Text Available In this study we have tried necessary condition and suitable for air balance and temperature in the operating room, using a fuzzy expert controller system and thermal cameras are designed. Condition for implementation and simulation of this system has been studied to see if it can be true or not performed in hospitals. This is a completely new method, all the operating room by a fuzzy controller with thermal picture environment has been properly balanced to ventilation system work properly. Therefore, the operating room is simulated using MATLAB software so fuzzy control system is supposed to be shown the benefits of this control system. Input parameters of the system are important factors in determining the balance temperature and ambient temperature. The publication of these parameters is considered as an output parameter. By the expert system, an account statement with the membership functions for input parameters were defined. After classification of ventilation systems and related information, using a concept designed interface that with MATLAB software has been simulated, transferred to the computer and also whole system operation in the operating room during hundred minutes is shown. The results revealed by this controller showed that in terms of economic and reliability and other has more advantages than the previous single-phase system.

  19. Simulating The Air-Condition Controlling In Operating Room And Improvement

    Directory of Open Access Journals (Sweden)

    Fereshteh Mohammadi

    2012-06-01

    Full Text Available In this study we have tried necessary condition and suitable for air balance and temperature inthe operating room, using a fuzzy expert controller system and thermal cameras are designed.Condition for implementation and simulation of this system has been studied to see if it can betrue or not performed in hospitals. This is a completely new method, all the operating room by afuzzy controller with thermal picture environment has been properly balanced to ventilationsystem work properly. Therefore, the operating room is simulated using MATLAB software sofuzzy control system is supposed to be shown the benefits of this control system. Inputparameters of the system are important factors in determining the balance temperature andambient temperature. The publication of these parameters is considered as an output parameter.By the expert system, an account statement with the membership functions for input parameterswere defined. After classification of ventilation systems and related information, using a conceptdesigned interface that with MATLAB software has been simulated, transferred to the computerand also whole system operation in the operating room during hundred minutes is shown. Theresults revealed by this controller showed that in terms of economic and reliability and other hasmore advantages than the previous single-phase system.

  20. Analyses of an air conditioning system with entropy generation minimization and entransy theory

    Science.gov (United States)

    Yan-Qiu, Wu; Li, Cai; Hong-Juan, Wu

    2016-06-01

    In this paper, based on the generalized heat transfer law, an air conditioning system is analyzed with the entropy generation minimization and the entransy theory. Taking the coefficient of performance (denoted as COP) and heat flow rate Q out which is released into the room as the optimization objectives, we discuss the applicabilities of the entropy generation minimization and entransy theory to the optimizations. Five numerical cases are presented. Combining the numerical results and theoretical analyses, we can conclude that the optimization applicabilities of the two theories are conditional. If Q out is the optimization objective, larger entransy increase rate always leads to larger Q out, while smaller entropy generation rate does not. If we take COP as the optimization objective, neither the entropy generation minimization nor the concept of entransy increase is always applicable. Furthermore, we find that the concept of entransy dissipation is not applicable for the discussed cases. Project supported by the Youth Programs of Chongqing Three Gorges University, China (Grant No. 13QN18).

  1. Silicagel-water adsorption cooling prototype system for mobile air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    De Boer, R.; Smeding, S.F.; Mola, S. [ECN Efficiency and Infrastructure, Petten (Netherlands)

    2009-09-15

    A prototype adsorption cooling system was developed for the purpose of on-board test of mobile air conditioning driven by waste heat from the engine. The system was designed, constructed and first tested in the laboratory of ECN. The performance under various static operating conditions was determined in the laboratory. The system can produce 2 kW of chilling power with a COP of 0.4. The prototype was afterward installed in the Fiat Grande Punto demonstration car by CRF. The system was connected to the heating and cooling systems of the car and tested. The performance in the car was comparable to the performance in the lab, indicating that system integration was successful. A waste heat driven adsorption cooling system can be applied for comfort cooling purposes in a car. The amount of waste heat that is freely available in the engine coolant circuit as well as its temperature level is sufficient to drive the adsorption cooling system and to produce enough cold to keep comfortable interior temperatures.

  2. Air

    Science.gov (United States)

    ... house) Industrial emissions (like smoke and chemicals from factories) Household cleaners (spray cleaners, air fresheners) Car emissions (like carbon monoxide) *All of these things make up “particle pollution.” They mostly come from cars, trucks, buses, and ...

  3. Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment

    International Nuclear Information System (INIS)

    From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other standards for radon in the workplace. (author)

  4. Controlled environment laboratory for the energy certification of refrigeration and air conditioning systems; Laboratorio de ambiente controlado para la certificacion energetica de sistemas de refrigeracion y aire acondicionado

    Energy Technology Data Exchange (ETDEWEB)

    Ambriz, Juan Jose; Romero Paredes, Hernando; Dorantes, Ruben [Universidad Autonoma Metropolitana, Mexico, D.F. (Mexico)

    1999-07-01

    In this paper the general characteristics of the Controlled Environment Laboratory (CELAB) are described and some of the possible tests that could be performed in this device to evaluate the energy efficiency in air conditioning systems, domestic refrigeration and industrial refrigeration, as well as tests to evaluate the hydrothermal comfort in national populations, are presented. [Spanish] En este trabajo se describen las caracteristicas generales del Laboratorio de Ambiente Controlado (LAB), y se presentan algunas de las posibles pruebas que podran ser desarrolladas en este dispositivo para evaluar la eficiencia energetica en sistemas de aire acondicionado, refrigeracion domestica y refrigeracion industrial, asi como para pruebas para evaluar el confort hidrotermico en poblaciones nacionales.

  5. Deriving realistic source boundary conditions for a CFD simulation of concentrations in workroom air.

    Science.gov (United States)

    Feigley, Charles E; Do, Thanh H; Khan, Jamil; Lee, Emily; Schnaufer, Nicholas D; Salzberg, Deborah C

    2011-05-01

    Computational fluid dynamics (CFD) is used increasingly to simulate the distribution of airborne contaminants in enclosed spaces for exposure assessment and control, but the importance of realistic boundary conditions is often not fully appreciated. In a workroom for manufacturing capacitors, full-shift samples for isoamyl acetate (IAA) were collected for 3 days at 16 locations, and velocities were measured at supply grills and at various points near the source. Then, velocity and concentration fields were simulated by 3-dimensional steady-state CFD using 295K tetrahedral cells, the k-ε turbulence model, standard wall function, and convergence criteria of 10(-6) for all scalars. Here, we demonstrate the need to represent boundary conditions accurately, especially emission characteristics at the contaminant source, and to obtain good agreement between observations and CFD results. Emission rates for each day were determined from six concentrations measured in the near field and one upwind using an IAA mass balance. The emission was initially represented as undiluted IAA vapor, but the concentrations estimated using CFD differed greatly from the measured concentrations. A second set of simulations was performed using the same IAA emission rates but a more realistic representation of the source. This yielded good agreement with measured values. Paying particular attention to the region with highest worker exposure potential-within 1.3 m of the source center-the air speed and IAA concentrations estimated by CFD were not significantly different from the measured values (P = 0.92 and P = 0.67, respectively). Thus, careful consideration of source boundary conditions greatly improved agreement with the measured values. PMID:21422277

  6. Photocatalytic TiO2 thin films for air cleaning : Effect of facet orientation, chemical functionalization, and reaction conditions

    OpenAIRE

    Stefanov, Bozhidar

    2015-01-01

    Poor indoor air quality is a source of adverse health effects. TiO2 coatings deposited on well-illuminated surfaces, such as window panes, can be used to fully mineralize indoor air pollutants by photocatalysis. In such applications it is important to ensure stable photocatalytic activity for a wide range of operating conditions, such as relative humidity and temperature, and to avoid deactivation of the catalyst. In this thesis photocatalytic removal of the indoor-pollutant acetaldehyde (CH3...

  7. The use of chained two-point clusters for the examination of associations of air pollution with health conditions

    OpenAIRE

    Mieczysław Szyszkowicz; Wesley S. Burr

    2016-01-01

    Objectives: There are a few accepted and intensively applied statistical methods used to study associations of ambient air pollution with health conditions. Among the most popular methods applied to assess short term air health effects are case-crossover (using events) and time-series methodologies (using counts). A few other techniques for studying counts of events have been proposed, including the Generalized Linear Mixed Models (GLMM). One suggested GLMM technique uses cluster structures b...

  8. Modelling of cooled-ceiling air-conditioning systems: Influences on indoor environment and energy consumption. Doctoral thesis

    Energy Technology Data Exchange (ETDEWEB)

    Niu, J.

    1994-06-14

    The contents presented in this thesis consist of four principal parts: (1) the critical review of turbulence CFD (Computational Fluid Dynamics) techniques and their application in building air flow study, and the experimental evaluation of the widely used k-epsilon turbulence model for in-room air flow situations; (2) the development of a thermodynamic mathematical model for cooled-ceiling air-conditioning systems, and the enhancement of an existing computer code ACCURACY, and the experimental validation of the convective parameters involved in the models; (3) the combined use of building dynamic simulation and CFD technique for the investigation of thermal comfort and ventilation effectiveness performance of three typical air-conditioning systems, the air-panel type cooled-ceiling (ACC) system, and the water-panel type cooled ceiling (CC) system; and (4) the use of the dynamic model coupled with air-handling-unit (AHU) and primary equipment models to simulate the annual energy consumption of CC systems and all-air systems and to estimate thermal performances of some passive cooling schemes, especially the evaporative free-cooling scheme. The review of the state-of-the-art of turbulence modeling shows that the k-epsilon turbulence model still remains the most-widely used engineering model.

  9. IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Danish participation 2007-2010. Appendix; IEA SHC Task 38 'Solar air-conditioning and refrigeration'. Dansk deltagelse 2007-2010. Bilag

    Energy Technology Data Exchange (ETDEWEB)

    Ellehauge, K. (Ellehauge og Kildemoes, Aarhus (Denmark)); Muenster, E. (PlanEnergi, Skoerping (Denmark)); Reinholdt, L. (Teknologisk Institut, Aarhus (Denmark)); Munds, S. (AC-Sun Aps, Horsens (Denmark))

    2011-03-15

    IEA SHC Task 38 'Solar Air-Conditioning and Refrigeration' ran from October 2006 to December 2010. Denmark was represented in the task from January 2007 to December 2010. The aim of the task was to encourage use of solar powered refrigeration and air conditioning systems in particular at residential, commercial and industrial sectors. Furthermore, the aim was to contribute to new research and development activities on new systems and concepts. The appendix contains the publications prepared by the Danish project group.(LN)

  10. Effect of operating conditions and particle properties on performance of vertical air-lift

    OpenAIRE

    Chladek, Jana; Enstad, Gisle; Melaaen, Morten Christian

    2011-01-01

    The effect of the fluidization air flow rate and the transport air velocity on the solids mass flow rate and the pressure drop along the transport pipe was investigated in a vertical air-lift. The use of two different materials, glass (150 μm) and zirconium oxide (260 μm) particles (Geldart’s B class), enabled to estimate the effect of particle properties on the air-lift performance. Different levels of the solids mass flow rate were obtained by varying the fluidization air flow rate while ke...

  11. Energy efficient hybrid nanocomposite-based cool thermal storage air conditioning system for sustainable buildings

    International Nuclear Information System (INIS)

    The quest towards energy conservative building design is increasingly popular in recent years, which has triggered greater interests in developing energy efficient systems for space cooling in buildings. In this work, energy efficient silver–titania HiTES (hybrid nanocomposites-based cool thermal energy storage) system combined with building A/C (air conditioning) system was experimentally investigated for summer and winter design conditions. HiNPCM (hybrid nanocomposite particles embedded PCM) used as the heat storage material has exhibited 7.3–58.4% of improved thermal conductivity than at its purest state. The complete freezing time for HiNPCM was reduced by 15% which was attributed to its improved thermophysical characteristics. Experimental results suggest that the effective energy redistribution capability of HiTES system has contributed for reduction in the chiller nominal cooling capacity by 46.3% and 39.6% respectively, under part load and on-peak load operating conditions. The HiTES A/C system achieved 27.3% and 32.5% of on-peak energy savings potential in summer and winter respectively compared to the conventional A/C system. For the same operating conditions, this system yield 8.3%, 12.2% and 7.2% and 10.2% of per day average and yearly energy conservation respectively. This system can be applied for year-round space conditioning application without sacrificing energy efficiency in buildings. - Highlights: • Energy storage is acquired by HiTES (hybrid nanocomposites-thermal storage) system. • Thermal conductivity of HiNPCM (hybrid nanocomposites-PCM) was improved by 58.4%. • Freezing time of HiNPCM was reduced by 15% that enabled improved energy efficiency. • Chiller nominal capacity was reduced by 46.3% and 39.6% in on-peak and part load respectively. • HiTES A/C system achieved appreciable energy savings in the range of 8.3–12.2%

  12. Energy and exergy analysis of a geothermal heat pump air conditioning system

    International Nuclear Information System (INIS)

    This paper considers the energy analysis of a heat pump system coupled to the ground by means of vertical exchangers, to verify which thermodynamic boundary conditions, in terms of thermal conductivity and diffusivity of the ground and the grout, make it competitive in comparison with other technologies harnessing atmospheric air as the heat source. The comparison is based on the maximum theoretical efficiency available in correspondence to the temperature effectively assumed by the thermal energy reservoirs in contact with the evaporator and the condenser during the operating conditions. The comparison of the two sources/sinks of heat, i.e. the ground and atmospheric air, represents the comparison between the time trend of the exergy of the two reservoirs required by an ideal GSHP and ASHP respectively. A fully transient heat transfer model able to handle on a time scale of a year or more and with a refinement of less than an hour is considered, since short term variations have significant effects on the overall performance of GSHP. In this paper the borehole heat transfer problem in the Laplace domain is solved for any trend and duration of thermal loads, taking into account an existing analytical approximation model of the full solution proposed by Lamarche and Beauchamp. A numerical inversion using the Inverse Discrete Fourier Transform is then applied to obtain the time domain solution. The method combines the flexibility and accuracy of the analytical model with the superior efficiency of the computational time offered by the numerical inversion if compared with that of methods based on the convolution scheme. - Highlights: • The energy and exergy analysis of a GSHP versus a ASHP system is considered. • The model works on a time scale of a year, with a refinement of less than an hour. • Flexibility and efficiency are combined by an analytical model and numerical inversion. • For which order of λ and α the GSHP is not competitive respect to ASHP is

  13. IMPACT OF HEATING AND AIR CONDITIONING SYSTEM OPERATION AND LEAKAGE ON VENTILATION AND INTERCOMPARTMENT TRANSPORT: STUDIES IN UNOCCUPIED AND OCCUPIED TENNESSEE VALLEY HOMES

    Science.gov (United States)

    Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay In 39 occupied houses. An average Increase in air infiltration rate of 0...

  14. Potential energy savings and environmental impacts of energy efficiency standards for vapor compression central air conditioning units in China

    Energy Technology Data Exchange (ETDEWEB)

    Lu Wei [Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Tsinghua University, Beijing 100084 (China)]. E-mail: tjluwei@163.com

    2007-03-15

    Owing to the rapid development of economy and the stable improvement of people's living standard, central air conditioning units are broadly used in China. This not only consumes large energy, but also results in adverse energy-related environmental issues. Energy efficiency standards are accepted effective policy tools to reduce energy consumption and pollutant emissions. Recently, China issued two national energy efficiency standards, GB19577-2004 and GB19576-2004, for vapor compression central air conditioning units for the first time. This paper first reviews the two standards, and then establishes a mathematic model to evaluate the potential energy savings and environmental impacts of the standards. The estimated results indicate implementing these standards will save massive energy, as well as benefit greatly to the environment. Obviously, it is significant to implement energy efficiency standards for central air conditioning units in China.

  15. Air

    International Nuclear Information System (INIS)

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  16. Energy performance assessment on central air-conditioning system of commercial building:A case study in China

    Institute of Scientific and Technical Information of China (English)

    周璇; 练斯甄; 闫军威; 康英姿

    2015-01-01

    Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity.A “holistic” approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP (coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.

  17. Carbon-ammonia pairs for adsorption refrigeration applications: ice making, air conditioning and heat pumping

    Energy Technology Data Exchange (ETDEWEB)

    Tamainot-Telto, Z.; Metcalf, S.J.; Critoph, R.E.; Zhong, Y.; Thorpe, R. [School of Engineering, University of Warwick, Gibbet Hall Road, Coventry CV4 7AL (United Kingdom)

    2009-09-15

    A thermodynamic cycle model is used to select an optimum adsorbent-refrigerant pair in respect of a chosen figure of merit that could be the cooling production (MJ m{sup -3}), the heating production (MJ m{sup -3}) or the coefficient of performance (COP). This model is based mainly on the adsorption equilibrium equations of the adsorbent-refrigerant pair and heat flows. The simulation results of 26 various activated carbon-ammonia pairs for three cycles (single bed, two-bed and infinite number of beds) are presented at typical conditions for ice making, air conditioning and heat pumping applications. The driving temperature varies from 80 C to 200 C. The carbon absorbents investigated are mainly coconut shell and coal based types in multiple forms: monolithic, granular, compacted granular, fibre, compacted fibre, cloth, compacted cloth and powder. Considering a two-bed cycle, the best thermal performances based on power density are obtained with the monolithic carbon KOH-AC, with a driving temperature of 100 C; the cooling production is about 66 MJ m{sup -3} (COP = 0.45) and 151 MJ m{sup -3} (COP = 0.61) for ice making and air conditioning respectively; the heating production is about 236 MJ m{sup -3} (COP = 1.50). (author) [French] Un modele du cycle thermodynamique est utilise pour selectionner le meilleur couple adsorbant-ammoniac sur la base de la production frigorifique (MJ m{sup -3}), la production de chaleur (MJ m{sup -3}) ou bien le coefficient de performance (COP). Ce modele est essentiellement base sur les equations d'etat de l'adsorption (adsorbant-ammoniac). Les resultats de simulation de 26 differents couples charbon actif-ammoniac sont presentes pour des conditions typiques de fabrication de la glace, de climatisation et de pompe a chaleur. La temperature de generation varie de 80 C a 200 C. Les simulations sont effectuees pour trois types de cycle: lit unique, deux-lits et un nombre infini de lits. Les charbons actifs etudies sont

  18. Energy Savings and Economics of Advanced Control Strategies for Packaged Air-Conditioning Units with Gas Heat

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2011-12-31

    Pacific Northwest National Laboratory (PNNL) with funding from the U.S. Department of Energy's Building Technologies Program (BTP) evaluated a number of control strategies that can be implemented in a controller, to improve the operational efficiency of the packaged air conditioning units. The two primary objectives of this research project are: (1) determine the magnitude of energy savings achievable by retrofitting existing packaged air conditioning units with advanced control strategies not ordinarily used for packaged units and (2) estimating what the installed cost of a replacement control with the desired features should be in various regions of the U.S. This document reports results of the study.

  19. Selection and performance assessment of Phase Change Materials for heating, ventilation and air-conditioning applications

    International Nuclear Information System (INIS)

    Highlights: • Performance evaluation of commercialized Phase Change Materials for building applications. • Selection and assessment by Multiple Criteria Decision Making (MCDM) approach. • Ranking of the commercialized Phase Change Materials (PCMs). • Simulation of top performing PCM using PCMExpress Valentin Energy Software. - Abstract: The rapid commercialization of Phase Change Materials (PCMs) for heating, ventilation and air-conditioning (HVAC) applications, has paved way for effective utilization of ambient thermal fluctuations. However, given a long list of contemporary candidates, it is crucial to select the best material to obtain maximum efficiency for any given application. This article attempts to extend Multiple Criteria Decision Making (MCDM) approach for ranking and selecting PCMs for domestic HVAC application. Firstly, Ashby approach has been employed for determining two novel figure of merits (FOM) to grade PCMs performance. The FOMs thus obtained were subjected to Pareto Optimality test. The graded materials were ranked using Technique for Order Preference by Similarity to Ideal Solution (TOPSIS). The relative weights for the different attributes were calculated using Shannon’s entropy method. In order to justify the rankings obtained, the top materials were subjected to a standard simulation study to evaluate their relative performance using PCMExpress with the aim of maintaining human comfort temperature. It was observed that the results obtained by simulation are in good agreement with those obtained using MCDM approach. The candidates with the best ranks showed significant improvement in ameliorating the temperature conditions. Thus it can be concluded that integration of MCDM approach for PCMs selection would prove to an economical and swift alternative technique for ranking and screening of materials

  20. New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink

    Energy Technology Data Exchange (ETDEWEB)

    Kiss, T.; Chaney, L.; Meyer, J.

    2013-07-01

    Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic system simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.

  1. Exergy analysis of a novel configuration of desiccant based evaporative air conditioning system

    International Nuclear Information System (INIS)

    Highlights: • A procedure is developed for exergy analyses of the system. • The exergy transports between the components are determined. • The exergy efficiency of the whole system is 40.7% at 15 °C reference temperature. - Abstract: In this work, a process is developed for exergy analyses of a novel configuration of desiccant based an evaporative air conditioning system. The exergy transfer and destruction between the components of the system are defined for the average measured variables obtained from the experimental results. The exergy formulations are carried out to the experimental system using the data collected during a typical operation of the system. The exergy output, specific flow exergy, exergy destruction, exergy input and exergy efficiency are determined. Furthermore, the sustainability assessment and relative irreversibility of components are obtained. It is found that the exergy efficiency of the entire experimental unit is 40.7% at a reference temperature of 15 °C. It is also observed that the exergy efficiencies of the entire system varies between 56% and 25% for reference temperature of 0–30 °C, respectively. The effects of reference temperature on the performance of the studied system are investigated. Based on the investigation, it is seen that an exergy analysis can provide beneficial knowledge with respect to the theoretical upper limit of the system performance

  2. Effect of oxygen enrichment in air on acid gas combustion under Claus conditions

    KAUST Repository

    Ibrahim, Salisu

    2013-09-01

    Results are presented to examine the combustion of acid gas (H2S and CO2) in hydrogen-fueled flames using a mixture of oxygen and nitrogen under Claus conditions (Φ = 3). Specifically the effect of oxygen enrichment in the above flames is examined. The compositions of acid gas examined are100% H2S and 50% H2S/50% CO2 with different percentages of oxygen enrichment (0%, 19.3% and 69.3%) in the oxygen/nitrogen mixtures. The results revealed that combustion of acid gas formed SO2 wherein the mole fraction of SO2 increased to an asymptotic value at all the oxygen concentrations examined. In addition, increase in oxygen enrichment of the air resulted in increased amounts of SO2 rather than the formation of more desirable elemental sulfur. In case of 50% H2S/50% CO2 acid gas, carbon monoxide mole fraction increased with oxygen enrichment which is an indicator to the availability of additional amounts of oxygen into the reaction pool. This gas mixture resulted in the formation of other sulfurous–carbonaceous compounds (COS and CS2) due to the presence of carbon monoxide. The results showed that the rate of COS formation increased with oxygen enrichment due to the availability of higher amounts of CO while that of CS2 reduced. The global reactions responsible for this observed phenomenon are presented.

  3. Experimental evaluation of automotive air-conditioning using HFC-134a and HC-134a

    Science.gov (United States)

    Nasution, Henry; Zainudin, Muhammad Amir; Aziz, Azhar Abdul; Latiff, Zulkarnain Abdul; Perang, Mohd Rozi Mohd; Rahman, Abd Halim Abdul

    2012-06-01

    An experimental study to evaluate the energy consumption of an automotive air conditioning is presented. In this study, these refrigerants will be tested using the experimental rig which simulated the actual cars as a cabin complete with a cooling system component of the actual car that is as the blower, evaporator, condenser, radiators, electric motor, which acts as a vehicle engine, and then the electric motor will operate the compressor using a belt and pulley system, as well as to the alternator will recharge the battery. The compressor working with the fluids HFC-134a and HC-134a and has been tested varying the speed in the range 1000, 1500, 2000 and 2500 rpm. The measurements taken during the one hour experimental periods at 2-minutes interval times for temperature setpoint of 20°C with internal heat loads 0, 500, 700 and 1000 W. The final results of this study show an overall better energy consumption of the HFC-134a compared with the HC-134a.

  4. Passive cooling for air-conditioning energy savings with new radiative low-cost coatings

    Energy Technology Data Exchange (ETDEWEB)

    Muselli, Marc [University of Corsica - UMR CNRS 6134, Vignola, Route des Sanguinaires, F-20000 Ajaccio (France)

    2010-06-15

    Passive cooling is considered as an alternative technology to avoid unwanted heat gains, to reduce urban heat islands and to generate cooling potential for buildings (limiting air-conditioning energy). According to materials and surface treatments, the roof can represent to be a major heat gain source from opaque elements of the building fabric, heating up the outer surface and increasing heat flow by conduction. This paper presents low-cost new radiative materials (1 Euro /m{sup 2}) allowing to limit heat gains during diurnal cycle for hot seasons. To evaluate the relevance of these new substrates, their reflective UV-VIS-IR behavior are studied and compared to classical roofed materials available in industrial and developing countries. A 48 m{sup 2} experimental roof having different surfaces (plate steel sheets, fiber cement, terra cotta tiles and corrugated sheets) allows to determine the temperature ratio {delta} between uncoated and coated materials. Up to 34% surface temperature gains are obtained for white coated CS, 25% for FC and {approx}18% for TCT and PSS. According to uncoated materials for a surface temperature T{sub 0} = 60 C, simulations showed that the low-cost white opaque reflective roofs (50 m{sup 2}) presented in this study would reduce cooling energy consumption by 26-49%. (author)

  5. Modeling and simulation of a solar powered two bed adsorption air conditioning system

    International Nuclear Information System (INIS)

    A simple lumped parameter model is established to investigate the performance of a solar powered adsorption air conditioning system driven by flat-type solar collectors with three different configurations of glazes: (i) single glazed cover; (ii) double glazed cover and (iii) transparent insulation material (TIM) cover. The dynamic performance of a continuous adsorption cycle using a double adsorber along with heat recovery is measured in terms of the temperature histories, gross solar coefficient of performance and specific cooling power. Also, the influences of some important design and operational parameters on the performance of the system are studied. It is found that the chosen three types of collector configurations make no big difference on the performance, but the adsorbent mass and lumped capacitance have significant effects on the system performance as well as on the system size. Simulation results indicate that the effect of overall heat transfer coefficient is not predominant if the cycle duration is longer. Also, there exists an optimum time to initiate the heating of the adsorbent bed in a day's operation

  6. Metal hydride work pair development and its application on automobile air conditioning systems

    Institute of Scientific and Technical Information of China (English)

    QIN Feng; CHEN Jiang-ping; ZHANG Wen-feng; CHEN Zhi-jiu

    2007-01-01

    Aiming at developing exhaust gas driving automobile air conditioning systems, a hydride pair LaNi4.61Mn0.26A10.13/La0.6Y0.4Ni4.8Mn0.2 was developed working at 393~473 K/293~323 K/263~273 K. Property tests showed that both alloys have flat plateau slopes and small hystereses; system theoretical coefficient of performance (COP) is 0.711. Based on this work pair, a function proving automobile metal hydride refrigeration system was constructed. The equivalent thermal conductivities of the activated reaction beds were merely 1.1~1.6 W/(m·K), which had not met practical requirement. Intermittent refrigeration cycles were achieved and the average cooling power was 84.6 W at 423 K/303 K/273 K with COP being 0.26. By altering cycling parameters, experiment data showed that cooling power and system COP increase with the growth of heat source temperature as well as pre-heating and regeneration time while decrease with heat sink temperature increment. This study confirms the feasibility of automobile metal hydride refrigeration systems, while heat transfer properties of reaction beds still need to be improved for better performance.

  7. Online Air-Conditioning Energy Management under Coalitional Game Framework in Smart Community

    Directory of Open Access Journals (Sweden)

    Wei Fan

    2016-08-01

    Full Text Available Motivated by the potential ability of air conditioning (A/C units in demand response, this paper explores how to utilize A/C units to increase the profit of a smart community. A coalitional game between the households and the load serving entity (LSE in a smart community is studied, where the LSE joins by selling renewable energy to householders and providing an energy saving service to them through an A/C controller. The A/C controller is designed to reduce the amount of electricity purchased from the main grid by controlling A/C units. An online A/C energy management algorithm is developed, based on Lyapunov optimization, that considers both the A/C energy consumption and the thermal comfort level of consumers. In order to quantify the contribution of A/C units, the Shapley value is adopted for distribution of the reward among the participating householders and the LSE, based on their contribution. The simulation result verifies the effectiveness of the proposed coalitional game for a smart community and the algorithm for A/C.

  8. Limit strength of rectangular air ventilation ducts under-seismic design condition

    International Nuclear Information System (INIS)

    The precise estimation of the limiting strength of heating, ventilating, and air conditioning ducts used in nuclear power plants is a key to the safe and economical design of the seismic supports. The formula for estimating the strength of ducts used up to this time, was derived from test results from small size ducts less than 500mm square. This data was extrapolated to obtain the strength of large ducts and therefore big margins had to be used. Consequently the seismic support spans of rectangular ducts are short and a large bulk volume of seismic support spans rectangular ducts are short and a large bulk volume of seismic support material is used in nuclear power plants. Accordingly, the authors carried out overall pure bending moment tests, shearing load tests, and local buckling load tests using large size rectangular ducts. In this paper the authors present the results of these tests and a method of designing seismic supports safely and economically by using the duct limiting strength estimation formula obtained from these tests

  9. Rainforest air-conditioning: the moderating influence of epiphytes on the microclimate in tropical tree crowns

    Science.gov (United States)

    Stuntz, Sabine; Simon, Ulrich; Zotz, Gerhard

    2002-05-01

    Epiphytes are often assumed to influence the microclimatic conditions of the tree crowns that they inhabit. In order to quantify this notion, we measured the parameters "temperature" (of the substrate surface and the boundary layer of air above it), "evaporative drying rate" and "evapotranspiration" at various locations within tree crowns with differing epiphyte assemblages. The host tree species was Annona glabra, which was either populated by one of three epiphyte species ( Dimerandra emarginata, Tillandsia fasciculata, or Vriesea sanguinolenta) or was epiphyte-free. We found that during the hottest and driest time of day, microsites in the immediate proximity of epiphytes had significantly lower temperatures than epiphyte-bare locations within the same tree crown, even though the latter were also shaded by host tree foliage or branches. Moreover, water loss through evaporative drying at microsites adjacent to epiphytes was almost 20% lower than at exposed microsites. We also found that, over the course of several weeks, the evapotranspiration in tree crowns bearing epiphytes was significantly lower than in trees without epiphytes. Although the influence of epiphytes on temperature extremes and evaporation rates is relatively subtle, their mitigating effect could be of importance for small animals like arthropods inhabiting an environment as harsh and extreme as the tropical forest canopy.

  10. Energy-Efficient Supermarket Heating, Ventilation, and Air Conditioning in Humid Climates in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Clark, J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    Supermarkets are energy-intensive buildings that consume the greatest amount of electricity per square foot of building of any building type in the United States and represent 5% of total U.S. commercial building primary energy use (EIA 2005). Refrigeration and heating, ventilation, and air-conditioning (HVAC) systems are responsible for a large proportion of supermarkets’ total energy use. These two systems sometimes work together and sometimes compete, but the performance of one system always affects the performance of the other. To better understand these challenges and opportunities, the Commercial Buildings team at the National Renewable Energy Laboratory investigated several of the most promising strategies for providing energy-efficient HVAC for supermarkets and quantified the resulting energy use and costs using detailed simulations. This research effort was conducted on behalf of the U.S. Department of Energy (DOE) Commercial Building Partnerships (CBP) (Baechler et al. 2012; Parrish et al. 2013; Antonopoulos et al. 2014; Hirsch et al. 2014). The goal of CBP was to reduce energy use in the commercial building sector by creating, testing, and validating design concepts on the pathway to net zero energy commercial buildings. Several CBP partners owned or operated buildings containing supermarkets and were interested in optimizing the energy efficiency of supermarket HVAC systems in hot-humid climates. These partners included Walmart, Target, Whole Foods Market, SUPERVALU, and the Defense Commissary Agency.

  11. Thermodynamic study of the effects of ambient air conditions on the thermal performance characteristics of a closed wet cooling tower

    International Nuclear Information System (INIS)

    A thermodynamic model was developed and used to assess the sensitivity of thermal performance characteristics of a closed wet cooling tower to inlet air conditions. In the present study, three cases of different ambient conditions are considered: In the first case, the average mid-winter and mid-summer conditions as well as the extreme case of high temperature and relative humidity, in Athens (Greece) during summer are considered according to the Greek Regulation for Buildings Energy Performance. In the second case, the varied inlet air relative humidity while the inlet air dry bulb temperature remains constant were taken into account. In the last case, the effects on cooling tower thermal behaviour when the inlet air wet bulb temperature remains constant were examined. The proposed model is capable of predicting the variation of air thermodynamic properties, sprayed water and serpentine water temperature inside the closed wet cooling tower along its height. The reliability of simulations was tested against experimental data, which were obtained from literature. Thus, the proposed model could be used for the design of industrial and domestic applications of conventional air-conditioning systems as well as for sorption cooling systems with solid and liquid desiccants where closed wet cooling towers are used for precooling the liquid solutions. The most important result of this theoretical investigation is that the highest fall of serpentine water temperature and losses of sprayed water are observed for the lowest value of inlet wet bulb temperature. Hence, the thermal effectiveness, which is associated with the temperature reduction of serpentine water as well as the operational cost, which is related to the sprayed water loss due to evaporation, of a closed wet cooling tower depend predominantly on the degree of saturation of inlet air.

  12. Performance of a hydrogen burner to simulate air entering scramjet combustors. [simulation of total temperature, total pressure, and volume fraction of oxygen of air at flight conditions

    Science.gov (United States)

    Russin, W. R.

    1974-01-01

    Tests were conducted to determine the performance of a hydrogen burner used to produce a test gas that simulates air entering a scramjet combustor at various flight conditions. The test gas simulates air in that it duplicates the total temperature, total pressure, and the volume fraction of oxygen of air at flight conditions. The main objective of the tests was to determine the performance of the burner as a function of the effective exhaust port area. The conclusions were: (1) pressure oscillations of the chugging type were reduced in amplitude to plus or minus 2 percent of the mean pressure level by proper sizing of hydrogen, oxygen, and air injector flow areas; (2) combustion efficiency remained essentially constant as the exhaust port area was increased by a factor of 3.4; (3) the mean total temperature determined from integrating the exit radial gas property profiles was within plus or minus 5 percent of the theoretical bulk total temperature; (4) the measured exit total temperature profile had a local peak temperature more than 30 percent greater than the theoretical bulk total temperature; and (5) measured heat transfer to the burner liner was 75 percent of that predicted by theory based on a flat radial temperature profile.

  13. Hot-wire air flow meter for gasoline fuel-injection system. Calculation of air mass in cylinder during transient condition; Gasoline funsha system yo no netsusenshiki kuki ryuryokei. Kato untenji no cylinder juten kukiryo no keisan

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y. [Hitachi Car Engineering, Ltd., Tokyo (Japan); Nishimura, Y.; Osuga, M.; Yamauchi, T. [Hitachi, Ltd., Tokyo (Japan)

    1997-10-01

    Air flow characteristics of hot-wire air flow meters for gasoline fuel-injection systems with supercharging and exhaust gas recycle during transient conditions were investigated to analyze a simple method for calculating air mass in cylinder. It was clarified that the air mass in cylinder could be calculated by compensating for the change of air mass in intake system by using aerodynamic models of intake system. 3 refs., 6 figs., 1 tab.

  14. AIR CONDITIONING IN OPERATING ROOMS AND INFECTION CONTROL – A REVIEW

    OpenAIRE

    May Socorro Martinez Afonso; Adenicia Custodia Silva e Souza; Anaclara Ferreira Veiga Tipple; Eliene Aparecida Machado; Eliane Alves Lucas

    2006-01-01

    ABSTRACT: This bibliographic survey in data banks such as MEDLINE, LILACS, SCIELO, Ministry of Health, among others aims at identifying what makes air conditioners a source of environmental contamination. The air is contaminated by particles which transport microorganisms. The sources of particles include patients and surgical staff. The control of the temperature, relative humidity, pressure, number of changes of air accomplished per hour, clothes, traffic, number of people in the rooms, mai...

  15. Variability and Risk Analysis of Hong Kong Air Quality Based on Monsoon and El Ni(n)o Conditions

    Institute of Scientific and Technical Information of China (English)

    Jong-Suk KIM; ZHOU Wen; Ho Nam CHEUNG; Chak Hang CHOW

    2013-01-01

    This study presents an exploratory analysis aimed at improving understanding of the variability of Hong Kong air quality associated with different climate conditions.Significantly negative correlations were found when Nifio 3 led particulate matter ≤10 μm PM10) and NO2 by 2-3 months over the Hong Kong territory,while the other pollutants (e.g.,O3,SO2) showed modest correlations.A significant decreasing trend in visibility was observed during the autumn and winter,which has potential implications for the air-quality degradation and the endangerment of human health in Hong Kong.In an El Ni(n)o summer,the visibility was relatively better,while visibility in other seasons was diminished.On the other hand,in La Ni(n)a events,significant changes occurred in visibility in winter and autumn.Air pollution indices were less sensitive to the South China Summer Monsoon (SCSM),but a relatively high correlation existed between the East Asian Winter Monsoon (EAWM) and air pollutants.Rainfall was lower during most of the strong EAWM years compared to the weak years.This result suggests that the pollutants that accumulate in Hong Kong are not easy to wash out,so concentrations remain at a higher level.Finally,based on the conditional Air Pollution Index (API) risk assessment,site-specific vulnerabilities were analyzed to facilitate the development of the air-quality warning systems in Hong Kong.

  16. Experimental Research of Variable Operating Performance on Water Source Multi-Connected Air-Conditioning System with Digital Scroll Compressor

    Directory of Open Access Journals (Sweden)

    Xingwang Zhu

    2013-05-01

    Full Text Available In this study, we study the water source heat pump and digital scroll compressor and experimentally in the multi-connected air-conditioning system. Variable performance is developed when the unit operates in refrigerating and heating mode. The maximum of refrigerating capacity is 36519.95W when inlet water temperature of the condenser is 30°C and dry-bulb temperature of indoor air is 32°C, at the same time the maximum of EER is 4.33 when inlet water temperature of the condenser is 20°C and dry-bulb temperature of indoor air is 27°C. The unit operates in heating mode, the maximum of heating capacity and EER is 33275.73W and 3.86 when inlet water temperature of the condenser is 30°C and dry-bulb temperature of indoor air is 20°C.

  17. Experimental Assessment of residential split type air-conditioning systems using alternative refrigerants to R-22 at high ambient temperatures

    International Nuclear Information System (INIS)

    Highlights: • R290, R407C and R410A in residential split A/C units at high ambient. • 1 and 2 TR residential air conditioners with R22 alternatives at high ambient. • Residential split unit performance at ambients up to 55 °C with R22 alternatives. - Abstract: Steady state performance of residential air conditioning systems using R22 and alternatives R290, R407C, R410A, at high ambient temperatures, have been investigated experimentally. System performance parameters such as optimum refrigerant charge, coefficient of performance, cooling capacity, power consumption, pressure ratio, power per ton of refrigeration and TEWI environmental factor have been determined. All refrigerants were tested in the cooling mode operation under high ambient air temperatures, up to 55 °C, to determine their suitability. Two split type air conditioner of 1 and 2 TR capacities were used. A psychrometric test facility was constructed consisting of a conditioned cool compartment and an environmental duct serving the condenser. Air inside the conditioned compartment was maintained at 25 °C dry bulb and 19 °C wet bulb for all tests. In the environmental duct, the ambient air temperature was varied from 35 °C to 55 °C in 5 °C increments. The study showed that R290 is the better candidate to replace R22 under high ambient air temperatures. It has lower TEWI values and a better coefficient of performance than the other refrigerants tested. It is suitable as a drop-in refrigerant. R407C has the closest performance to R22, followed by R410A

  18. Conditions for using outdoor-air inlet filter for removing UFP in residential buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Ardkapan, Siamak Rahimi; Bergsøe, Niels Christian;

    2012-01-01

    The purpose of this project is to study the possibility of achieving a reduction of ultrafine particles in the indoor air by placing a filter at the outdoor-air inlet in residential buildings with exhaust ventilation or natural ventilation. This paper presents field measurements of airflow rates ...

  19. Contents of nitrogen and phosphorus in leaves of woody plants under conditions of air contamination with industrial wastes

    Energy Technology Data Exchange (ETDEWEB)

    Tarabrin, V.P.; Shatskaya, R.M.; Chernyshova, L.V.

    1971-01-01

    A study of nitrogen and phosphorus contents in leaves of woody plants was conducted against a background of different air and soil contamination with wastes of metallurgic and coke-chemical plants. It is found that content of total protein nitrogen and phosphorus in leaves of woody plants decreases with aging of the leaves (from spring to autumn) in all the plants under study. Air contamination causes at the beginning of the vegetation period an increase and then, under conditions of great contamination a drop in the content of total nitrogen in comparison with control. The drought resistant plants - Quercus robur L. and Robinia pseudoacacia L. under conditions of air contamination with industrial wastes preserve exchange of nitrogen protein and phosphorus at a higher level in comparison with less resistant Aesculus hippocastanum L. and Tilia parviflora Ehrh.

  20. Relationship between the merit factor of thermoelectric materials and the air conditioning unit of urban electric cars

    International Nuclear Information System (INIS)

    The main benefit of electric cars is to reduce air pollution in cities that is thus desirable to equip them with non polluting air conditioning units and this rules out frigorific compressors operating with CFC. The planned replacement of CFC by HFC is at best an interim solution. The best solution is certainly to use thermoelectric air conditioning units, which are inherently pollution-free. However, these have a fairly low COPF when compared to traditional compressor units. We study the relationship between the cooling of the interior of urban electric cars and the merit factor of the thermoelectric material in their Peltier unit. This should help provide concrete target properties of future T E materials. copyright 1995 American Institute of Physics

  1. Effectiveness of photocatalytic filter for removing volatile organic compounds in the heating, ventilation, and air conditioning system.

    Science.gov (United States)

    Yu, Kuo-Pin; Lee, Grace Whei-May; Huang, Wei-Ming; Wu, Chih-Cheng; Lou, Chia-ling; Yang, Shinhao

    2006-05-01

    Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters. PMID:16739804

  2. Differential Responses in Two Varieties of Winter Wheat to Elevated Ozone Concentration Under Fully Open-air Field Conditions

    Science.gov (United States)

    Two modern cultivars (Yangmai16 (Y16) and Yangfumai 2 (Y2)) of winter wheat (Triticum aestivum L.) of almost identical phenology were investigated for impacts of elevated ozone concentration (E-O3) on physiological characters related to photosynthesis under fully open-air field conditions in China. ...

  3. Competency Index for Air Conditioning and Refrigeration Programs in Missouri. A Crosswalk of Selected Instructional Materials against Missouri's Competency Profile.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This index was developed to help air conditioning and refrigeration instructors in Missouri use existing instructional materials and keep track of student progress on the VAMS system. The list was compiled by a committee of instructors who selected appropriate references and identified areas that pertained to Missouri competencies. The index lists…

  4. Craft-joule project: air-cooled water LiBr absorption cooling machine of low capacity for air conditioning (ACABMA)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, A; Castro, J; Perez Segarra, C.D [Universitat Politecnica de Catalunya, Barcelona (Spain); Lucena, M.A [Instituto Nacional de Tecnica Aeroespecial (Spain)] (and others)

    2000-07-01

    The ACABMA (Air-Cooled water-LiBr Absorption cooling Machine of low capacity for Air- conditioning) project is a Craft-Joule Project within the framework of the Non Nuclear Energy Programme Joule III coordinated by the Centre Technologic de Transferencia de Calor (CTTC). The basic objective of this project is the development of a new air-cooled absorption cooling machine for air-conditioning, in the low power sector market. Making use of water-LiBr technology together with the air-cooling feature, it is possible to reach a better relationship between quality (in terms of performance, ecology, etc.) and price of such absorption machines, than the ones existing on the market. Air-cooling instead of water cooling saves installation costs specially in small systems and removes the demand for cooling water (an important aspect in Southern-European countries), thus increasing the possible application range. The main interest for the SME proposers is to take advantage of the increasing cooling demand in Europe, specially in southern countries. Another point of interest for the SME proposers is the development of a cheaper cooling and heating system in terms of energy and installation costs. In this moment the solar cooling systems are approx. 30% more expensive than the conventional ones. A cheaper absorption machine due to the air-cooling feature together with the possibility of energy savings due to low generator temperatures, that allow the absorption machine for solar applications or waste heat, will lead to solar cooling and heating systems more competitive to the conventional ones. In order to achieve the above mentioned goal, the following step are necessary and will be carried out in this project: i)solution of the air-cooling of the water-LiBr machine, the main problem that up to now has not allowed commercialization, ii)reduction of the size of the air-cooled elements of the machine in order to reduce the machine costs, iii)development of an efficient control

  5. Earth, Wind and Fire. Natural air conditioning; Earth, Wind and Fire. Natuurlijke airconditioning

    Energy Technology Data Exchange (ETDEWEB)

    Bronsema, B.

    2013-06-07

    Starting point for the Earth, Wind and Fire research, of which the sub-concepts of Ventec roof, Climate Cascade and Solar Chimney are an integral part of the (Architectural) building design, are the following hypotheses: (1) An integrated approach of Architecture / Constructions and Climate Design is capable of using the available ambient energy in the form of earth mass, wind, and sun, to condition the air mainly naturally in a building; (2) The sub-concepts can be modeled and validated, in order to be able to reliably support the design process in practice; and (3) The sub-concepts can individually or in combination contribute to the realization of zero energy buildings [Dutch] Airconditioning van gebouwen kan volledig met natuurlijke middelen, zonder mechanische ventilatie. Dat stelt de auteur in zijn proefschrift. Hij wil met vallend water, zon en wind een energiepositief kantoor realiseren. Bronsema is nu op zoek naar een gebouw voor een grootschalige praktijkproef met zijn Earth, Wind and Fire-concept. Het systeem bestaat uit drie hoofdonderdelen: het Ventecdak, de Klimaatcascade en de Zonneschoorsteen. Het Ventecdak zorgt voor aanvoer van verse en afvoer van vuile lucht door gebruikmaking van over- en onderdrukken. Die lucht wordt via de klimaatcascade toegevoerd en via een Zonneschoorsteen afgevoerd. Een mock-up van de Zonneschoorsteen is gerealiseerd als een elf meter hoge toren, die met opgevangen warmte van invallend zonlicht ventilatielucht verwarmt. Het op gang brengen van de luchtstroom gebeurt in de Klimaatcascade. Dit is een bouwkundige schacht waarin van bovenaf waterdruppels worden gesproeid waarmee de lucht kan worden gekoeld of verwarmd.

  6. Anatomical Details of the Rabbit Nasal Passages and Their Implications in Breathing, Air Conditioning, and Olfaction.

    Science.gov (United States)

    Xi, Jinxiang; Si, Xiuhua A; Kim, Jongwon; Zhang, Yu; Jacob, Richard E; Kabilan, Senthil; Corley, Richard A

    2016-07-01

    The rabbit is commonly used as a laboratory animal for inhalation toxicology tests and detail knowledge of the rabbit airway morphometry is needed for outcome analysis or theoretical modeling. The objective of this study is to quantify the morphometric dimension of the nasal airway of a New Zealand white rabbit and to relate the morphology and functions through analytical and computational methods. Images of high-resolution MRI scans of the rabbit were processed to measure the axial distribution of the cross-sectional areas, perimeter, and complexity level. The lateral recess, which has functions other than respiration or olfaction, was isolated from the nasal airway and its dimension was quantified separately. A low Reynolds number turbulence model was implemented to simulate the airflow, heat transfer, vapor transport, and wall shear stress. Results of this study provide detailed morphological information of the rabbit that can be used in the studies of olfaction, inhalation toxicology, drug delivery, and physiology-based pharmacokinetics modeling. For the first time, we reported a spiral nasal vestibule that splits into three paths leading to the dorsal meatus, maxilloturbinate, and ventral meatus, respectively. Both non-dimensional functional analysis and CFD simulations suggested that the airflow in the rabbit nose is laminar and the unsteady effect is only significantly during sniffing. Due to the large surface-to-volume ratio, the maxilloturbinate is highly effective in warming and moistening the inhaled air to body conditions. The unique anatomical structure and respiratory airflow pattern may have important implications for designing new odorant detectors or electronic noses. Anat Rec, 299:853-868, 2016. © 2016 Wiley Periodicals, Inc. PMID:27145450

  7. SESSA: Expert system for the selection of air conditioning equipment; SESEAA: Sistema experto para la seleccion de equipos de aire acondicionado

    Energy Technology Data Exchange (ETDEWEB)

    Kemper Valverde, Nicolas; Cardenas Perez, Edgar [Laboratorio de Sistemas Inteligentes, Centro de Instrumentos de la Universidad Nacional Autonoma de Mexico (UNAM), Mexico, D. F. (Mexico)

    1998-12-31

    The problem of selecting air conditioning and refrigeration equipment is quite wide and complex, since it encompasses from the application of the basic principles of physics and of thermodynamics up to the classic engineering design problems; these in turn can be numberless since they vary from place to place depending on multiple factors such as the region geographic and economic conditions. On the other hand, account most be taken of several elements such as windows, walls, and its specific geographical orientation, roofs, floors, partitions, equipment, lighting, etc., all this exerts influence in the complexity that represents the selection process. This paper describes a useful informatics tool to make it easy the selection process in air conditioning installations, taking into account multiple saving and efficient use of energy criteria, reflected in the operation process of these installations. [Espanol] El problema de seleccion de sistemas de aire acondicionado y de refrigeracion es bastante amplio y complejo, ya que abarca desde la aplicacion de los principios basicos de la fisica y la termodinamica hasta los problemas clasicos de diseno de ingenieria; estos a la vez pueden ser innumerables ya que varian de un lugar a otro y de un proyecto a otro, dependiendo de multiples factores tales como las condiciones geograficas y economicas de la region. Por otra parte se deben tomar en cuenta diversos elementos como son: ventanas, muros y sus orientaciones especificas, techos, pisos, particiones, equipos, iluminacion, etc., todo esto influye en la complejidad que representa el proceso de seleccion. En el presente trabajo se describe una herramienta informatica para facilitar el proceso de seleccion de instalaciones de aire acondicionado, tomando en cuenta multiples criterios de ahorro y uso eficiente de energia que se reflejan durante el proceso de operacion de estas instalaciones.

  8. Cold Vacuum Drying facility heating, ventilation, and Air Conditioning system design description

    International Nuclear Information System (INIS)

    This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), electrical power distribution system (including standby power), compressed air system, Chilled Water (CHW) system, drainage system, and other Cold Vacuum Drying (CVD) control systems not addressed in this SDD

  9. Air conditioning systems of Porsche Panamera; Das Klimatisierungssystem des Porsche Panamera

    Energy Technology Data Exchange (ETDEWEB)

    Mall, Gernot; Deyhle, Hagen [Porsche AG, Stuttgart (Germany); Engelhardt, Martin [Behr GmbH und Co. KG, Stuttgart (Germany); Gremme, Johannes [BehrHella Thermocontrol GmbH, Lippstadt (Germany)

    2010-07-01

    The Porsche Panama, an innovative Gran Turismo is the newest edition to the Porsche sportscar family. The Panamera climate control system is a major contributor in achieving the goal of premium driver comfort. In addition to excellent performance and comfort requirements on the system and package and an uncompromising lightweight design, premium comfort for the rear seat passengers was of special emphasis. These targets were achieved through a newly developed 2- respective 4-zone climate control system. The climatic comfort from the passenger's point of view is enhanced due to the ability to individually set temperature, air distribution and air volume for every passenger. The system incorporates a model based ''air volume control'' and uses a distinguishing feature, a dashboard integrated air distribution field. (orig.)

  10. Onset conditions for positive direct current corona discharges in air under the action of photoionization

    Science.gov (United States)

    Zheng, Yuesheng; Zhang, Bo; He, Jinliang

    2011-12-01

    This paper presents a numerical model for the inception of positive dc corona discharges in air near cylindrical anodes, which plays a bridge role between the classic positive corona onset criterion and the photoionization model considering the effective radiation wavelength. The predicted onset voltages agree well with Peek's experimental data in a wide range of conductor radii and relative air densities. The influence of the collisional quenching of emitting excited states on the surface onset field is significant with low air density or small conductor radius. Within the effective radiation wavelength, numerical expressions for the photon absorption coefficient in air and Townsend's second coefficient due to photoionization are deduced on the basis of the new model. A different perspective on the classic coefficients is given.

  11. Study of Air Ingress Across the Duct During the Accident Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Yassin [Texas A & M Univ., College Station, TX (United States)

    2013-05-06

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  12. Study of Air Ingress Across the Duct During the Accident Conditions

    International Nuclear Information System (INIS)

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  13. ASME N511-19XX, Standard for periodic in-service testing of nuclear air treatment, heating, ventilating and air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    A draft version of the Standard is presented in this document. The Standard covers the requirements for periodic in-service testing of nuclear safety-related air treatment, heating, ventilating, and air conditioning systems in nuclear facilities. The Standard provides a basis for the development of test programs and does not include acceptance criteria, except in cases where the results of one test influence the performance of other tests. The Standard covers general inspection and test requirements, reference values, inspection and test requirements, generic tests, acceptance criteria, in-service test requirements, testing following an abnormal incident, corrective action requirements, and quality assurance. Mandatory appendices provide a visual inspection checklist and four test procedures. Non-mandatory appendices provide additional information and guidance on mounting frame pressure leak test procedure, corrective action, challenge gas substitute selection criteria, and test program development. 8 refs., 10 tabs.

  14. Experimental Research of Variable Operating Performance on Water Source Multi-Connected Air-Conditioning System with Digital Scroll Compressor

    OpenAIRE

    Xingwang Zhu; Xueli Nie; Yanli Lv; Chaoxin Wang; Yugui Su

    2013-01-01

    In this study, we study the water source heat pump and digital scroll compressor and experimentally in the multi-connected air-conditioning system. Variable performance is developed when the unit operates in refrigerating and heating mode. The maximum of refrigerating capacity is 36519.95W when inlet water temperature of the condenser is 30°C and dry-bulb temperature of indoor air is 32°C, at the same time the maximum of EER is 4.33 when inlet water temperature of the condenser is 20°C and dr...

  15. Shelf life of air and modified atmosphere-packaged fresh tilapia (Oreochromis niloticus) fillets stored under chilled and superchilled conditions

    OpenAIRE

    Cyprian, Odoli; Lauzon, Hélène L; Jóhannsson, Ragnar; Sveinsdóttir, Kolbrún; Arason, Sigurjón; Martinsdóttir, Emilía

    2012-01-01

    Optimal packaging and storage conditions for fresh tilapia fillets were established by evaluating sensory and microbiological changes, as well as monitoring physicochemical properties. Nile tilapia (Oreochromis niloticus) farmed in recirculation aquaculture system was filleted, deskinned, and packaged in air and 50% CO2/50% N2 prior to chilling and superchilling storage at 1°C and −1°C. Sensory analysis of cooked samples revealed a shelf life of 13–15 days for air-packaged fillets during stor...

  16. Turbulent Boundary Layer on a Finely Perforated Surface Under Conditions of Air Injection at the Expense of External Flow Resources

    Science.gov (United States)

    Kornilov, V. I.; Boiko, A. V.; Kavun, I. N.

    2015-11-01

    The characteristics of an incompressible turbulent boundary layer on a flat plate with air blown in though a finely perforated surface from an external confined flow through an input device, located on the "idle" side of the plate, have been investigated experimentally and numerically. A stable decrease in the local values of the coefficient of surface friction along the plate length that attains 85% at the end of the perforated portion is shown. The experimental and calculated data obtained point to the possibility of modeling, under earth conditions, the process of controlling a turbulent boundary layer with air injection by using the resources of an external confined flow.

  17. Environmental impact of the programs of substitution of room type air conditioning equipment; Impacto ambiental de los programas de sustitucion de equipos de aire tipo cuarto

    Energy Technology Data Exchange (ETDEWEB)

    Alarcon Aleman, Jose Mauricio [OLADE, Quito (Ecuador)

    2002-09-01

    The present article approaches in a general way the relation that exists between the environment and the saving of electrical energy, especially in the Programs of Demand Side Management (DSM). In particular form the potential environmental impacts are described, derived of the use and the discard of the room type air conditioning equipment, goes deep into the characteristics of their cooling fluids, as well as in the relation that these keep with the protocols of Montreal and Kyoto. Finally, this article comments the incidence which have, the manufacturers as the institutions that implement DSM programs, on the environmental part of the programs of substitution of room type air conditioning equipment. In addition it is briefly described, the pilot program developed by Fideicomiso para el Ahorro de Energia Electrica (FIDE) as a successful case. [Spanish] En forma general, el presente articulo aborda la relacion que existe entre el medio ambiente y el ahorro de energia electrica, especialmente en los Programas de Administracion por el Lado de la Demanda (ALD). En forma particular se describen los impactos ambientales potenciales, derivados del uso y desecho de los equipos de aire acondicionado tipo cuarto, se ahonda en las caracteristicas de sus refrigerantes, asi como en la relacion que estos guardan con los protocolos de Montreal y Kioto. Finalmente, se comenta la incidencia que tienen, tanto los fabricantes como las instituciones que implementan programas de ALD, sobre la parte ambiental de los programas de sustitucion de equipos de aire acondicionado tipo cuarto. Ademas se describe brevemente, el programa piloto desarrollado por el Fideicomiso para el Ahorro de Energia Electrica (FIDE) como un caso exitoso.

  18. Characteristic Evaluation on the Cooling Performance of an Electrical Air Conditioning System Using R744 for a Fuel Cell Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-05-01

    Full Text Available The objective of this study was to investigate the cooling performance characteristics of an electrical air conditioning system using R744 as an alternative of R-134a for a fuel cell electric vehicle. In order to analyze the cooling performance characteristics of the air conditioning system using R744 for a fuel cell electric vehicle, an electrical air conditioning system using R744 was developed and tested under various operating conditions according to both inlet air conditions of the gas cooler and evaporator and compressor speed. The cooling capacity and coefficient of performance (COP forcooling of the tested air conditioning system were up to 6.4 kW and 2.5, respectively. In addition, the electrical air conditioning system with R744 using an inverter driven compressor showed better performance than the conventional air conditioning system with R-134a under the same operating conditions. The observed cooling performance of the developed electrical air conditioning system was found to be sufficient for cooling loads under various real driving conditions for a fuel cell electric vehicle.

  19. Dynamic Adjustment of Climatological Ozone Boundary Conditions for Air-Quality Forecasts

    Directory of Open Access Journals (Sweden)

    P. A. Makar

    2010-06-01

    Full Text Available Ten different approaches for applying lateral and top climatological boundary conditions for ozone have been evaluated using the off-line regional air-quality model AURAMS. All ten approaches employ the same climatological ozone profiles, but differ in the manner in which they are applied, via the inclusion or exclusion of (i a dynamic adjustment of the climatological ozone profile in response to the model-predicted tropopause height, (ii a sponge zone for ozone on the model top, (iii upward extrapolation of the climatological ozone profile, and (iv different mass consistency corrections. The model performance for each approach was evaluated against North American surface ozone and ozonesonde observations from the BAQS-Met field study period in the summer of 2007. The original daily one-hour maximum surface ozone biases of about +15 ppbv were greatly reduced (halved in some simulations using alternative methodologies. However, comparisons to ozonesonde observations showed that the reduction in surface ozone bias sometimes came at the cost of significant positive biases in ozone concentrations in the free troposphere and upper troposphere. The best overall performance throughout the troposphere was achieved using a methodology that included dynamic tropopause height adjustment, no sponge zone at the model top, extrapolation of ozone when required above the limit of the climatology, and no mass consistency corrections (global mass conservation was still enforced. The simulation using this model version had a one-hour daily maximum surface ozone bias of +8.6 ppbv, with small reductions in model correlation, and the best comparison to ozonesonde profiles. This recommended and original methodologies were compared for two further case studies: a high-resolution simulation of the BAQS-Met measurement intensive, and a study of the downwind region of the Canadian Rockies. Significant improvements were noted for the high resolution simulations during the

  20. Effect of conditions of air-lift type reactor work on cadmium adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Filipkowska, Urszula; Szymczyk, Paula Szymczyk; Kuczajowska-Zadrozna, Malgorzata; Joezwiak, Tomasz [University of Warmia and Mazury in Olsztyn, Warszawska (Poland)

    2015-10-15

    We investigated cadmium sorption by activated sludge immobilized in 1.5% sodium alginate with 0.5% polyvinyl alcohol. Experiments were conducted in an air-lift type reactor at the constant concentration of biosorbent reaching 5 d.m./dm{sup 3}, at three flow rates: 0.1, 0.25 and 0.5 V/h, and at three concentrations of the inflowing cadmium solution: 10, 25 and 50mg/dm{sup 3}. Analyses determined adsorption capacity of activated sludge immobilized in alginate as well as reactor's work time depending on flow rate and initial concentration of the solution. Results achieved were described with the use of Thomas model. The highest adsorption capacity of the sorbent (determined from the Thomas model), i.e., 200.2mg/g d.m. was obtained at inflowing solution concentration of 50mg/dm{sup 3} and flow rate of 0.1V/h, whereas the lowest one reached 53.69mg/g d.m. at the respective values of 10mg/dm{sup 3} and 0.1 V/h. Analyses were also carried out to determine the degree of biosorbent adsorption capacity utilization at the assumed effectiveness of cadmium removal - at the breakthrough point (C=0.05*C{sub 0}) and at adsorption capacity depletion point (C−0.9*C0). The study demonstrated that the effectiveness of adsorption capacity utilization was influenced by both the concentration and flow rate of the inflowing solution. The highest degree of sorbent capacity utilization was noted at inflowing solution concentration of 50mg/dm{sup 3} and flow rate of 0.1 V/h, whereas the lowest one at the respective values of 10mg/dm{sup 3} and 0.1 V/h. The course of the process under dynamic conditions was evaluated using coefficients of tangent inclination - a, at point C/C{sub 0}=1/2. A distinct tendency was demonstrated in changes of tangent slope a as affected by the initial concentration of cadmium and flow rate of the solution. The highest values of a coefficient were achieved at the flow rate of 0.1 V/h and initial cadmium concentration of 50mg/dm{sup 3}.