WorldWideScience

Sample records for acetabular reinforcement ring

  1. [Effects of Surgically Treated Pelvic Ring and Acetabular Fractures on Postural Control].

    Science.gov (United States)

    Lang, P; Schnegelberger, A; Riesner, H-J; Stuby, F; Friemert, B; Palm, H-G

    2016-04-01

    The aim of surgical treatment of pelvic ring and acetabular fractures is to allow rapid mobilisation of patients in order to restore stance and gait stability (postural control), as this significantly correlates with a positive outcome. The regulation of postural stability is mainly controlled by transmission of proprioceptive stimuli. In addition, the pelvis serves as a connection between the legs and the spine and thus is also of great importance for mechanical stabilisation. It remains unclear whether surgical treatment of pelvic ring and acetabular fractures affects the regulation of postural control. Therefore, the aim of this study was to examine the impact of surgically treated pelvic ring and acetabular fractures on postural stability by means of computerised dynamic posturography (CDP) after a mean of 35 months and to compare the results with a healthy control group. A retrospective case control study of 38 patients with surgically treated pelvic ring and acetabular fractures and 38 healthy volunteers was carried out using CDP. The average time of follow-up was 35 (12-78) months. The most important outcome parameter in this investigation was the overall stability index (OSI). Hip joint mobility, the health-related quality of life (SF-12) and pain were supplementary outcome parameters. It was found that surgically treated pelvic ring and acetabular fractures had no influence on postural stability. The OSI was 2.1 ° in the patient group and 1.9 ° in the control group. There was no significant difference between the groups in hip joint mobility. A total of 52 % of patients showed no or only mild pain. Mean health-related quality of life was the same as in the total population. Surgically treated pelvic ring and acetabular fractures do not lead to deterioration in postural control in the mid term. This is of high prognostic importance for rapid mobilisation of the patients. Therefore no increase in the risk of falling is expected after successfully

  2. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    LENUS (Irish Health Repository)

    Banks, Louisa N

    2012-02-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient\\'s weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  3. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    Science.gov (United States)

    Banks, Louisa N; McElwain, John P

    2010-04-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  4. Importance of preoperative imaging in acetabular revision surgery - a case report.

    Science.gov (United States)

    Schmitz, Hc; Egidy, Cc; Al-Khateeb, H; Cárdenas, G; Gehrke, T; Kendoff, D

    2012-01-01

    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures.In our case, a major bony defect of the acetabulum was a result of the protrusion of an implanted reinforcement ring. A preoperative, contrast-enhanced CT scan showed that the urethra was in close proximity to the hook of the reinforcement ring.The preoperative imaging aided in identifying and understanding the potential complications that could occur intraoperatively. Additionally, it delineated the intact anatomic structures prior to surgery, which could have medico-legal implications.The importance of preoperative imaging and the existing literature is discussed within this case description.

  5. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  6. Loosening After Acetabular Revision

    DEFF Research Database (Denmark)

    Beckmann, Nicholas A.; Weiss, Stefan; Klotz, Matthias C.M.

    2014-01-01

    The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years...

  7. Mechanical improvement of metal reinforcement rings for a finite ring-shaped superconducting bulk

    Science.gov (United States)

    Huang, Chen-Guang; Zhou, You-He

    2018-03-01

    As a key technique, reinforcement of type-II superconducting bulks with metal rings can efficiently improve their mechanical properties to enhance the maximum trapped field. In this paper, we study the magnetostrictive and fracture behaviors of a finite superconducting ring bulk reinforced by three typical reinforcing structures composed of metal rings during the magnetizing process by means of the minimization of magnetic energy and the finite element method. After a field-dependent critical current density is adopted, the magnetostriction, pinning-induced stress, and crack tip stress intensity factor are calculated considering the demagnetization effects. The results show that the mechanical properties of the ring bulk are strongly dependent on the reinforcing structure and the material and geometrical parameters of the metal rings. Introducing the metal ring can significantly reduce the hoop stress, and the reduction effect by internal reinforcement is much improved relative to external reinforcement. By comparison, bilateral reinforcement seems to be the best candidate structure. Only when the metal rings have particular Young's modulus and radial thickness will they contribute to improve the mechanical properties the most. In addition, if an edge crack is pre-existing in the ring bulk, the presence of metal rings can effectively avoid crack propagation since it reduces the crack tip stress intensity factor by nearly one order of magnitude.

  8. Acetabular reconstruction with human and bovine freeze-dried bone grafts and a reinforcement device

    Directory of Open Access Journals (Sweden)

    Ricardo Rosito

    2008-01-01

    Full Text Available BACKGROUND: This is a cohort trial (1997-2005 of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG and a reinforcement device. OBJECTIVE: To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS: There were two groups: I (n=26 receiving human grafts and II (n=25 receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d'Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn's et al. criteria for radiographic bone incorporation. RESULTS: No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424. CONCLUSION: The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty.

  9. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    Full Text Available History of present illness: A 77-year-old female presented to her primary care physician (PCP with right hip pain after a mechanical fall. She did not lose consciousness or have any other traumatic injuries. She was unable to ambulate post-fall, so X-rays were ordered by her PCP. Her X-rays were concerning for a right acetabular fracture (see purple arrows, so the patient was referred to the emergency department where a computed tomography (CT scan was ordered. Significant findings: The non-contrast CT images show a minimally displaced comminuted fracture of the right acetabulum involving the acetabular roof, medial and anterior walls (red arrows, with associated obturator muscle hematoma (blue oval. Discussion: Acetabular fractures are quite rare. There are 37 pelvic fractures per 100,000 people in the United States annually, and only 10% of these involve the acetabulum. They occur more frequently in the elderly totaling an estimated 4,000 per year. High-energy trauma is the primary cause of acetabular fractures in younger individuals and these fractures are commonly associated with other fractures and pelvic ring disruptions. Fractures secondary to moderate or minimal trauma are increasingly of concern in patients of advanced age.1 Classification of acetabular fractures can be challenging. However, the approach can be simplified by remembering the three basic types of acetabular fractures (column, transverse, and wall and their corresponding radiologic views. First, column fractures should be evaluated with coronally oriented CT images. This type of fracture demonstrates a coronal fracture line running caudad to craniad, essentially breaking the acetabulum into two halves: a front half and a back half. Secondly, transverse fractures should be evaluated by sagittally oriented CT images. By definition, a transverse fracture separates the acetabulum into superior and inferior halves with the fracture line extending from anterior to posterior

  10. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    International Nuclear Information System (INIS)

    Werner, Clement M.L.; Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H.; Ruckstuhl, Thomas; Bouaicha, Samy

    2011-01-01

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE ( 12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  11. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  12. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  13. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Clement M.L. [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland); University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H. [University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Ruckstuhl, Thomas; Bouaicha, Samy [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland)

    2011-11-15

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE (<20 ) or the AI (>12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  14. Orientation factor and number of fibers at failure plane in ring-type steel fiber reinforced concrete

    International Nuclear Information System (INIS)

    Lee, C.; Kim, H.

    2010-01-01

    Considering the probabilistic distributions of fibers in ring-type steel fiber reinforced concrete, the orientation factor and the number of ring-type steel fibers crossing the failure plane were theoretically derived as a function of fiber geometry, specimen dimensions, and fiber volume fraction. A total number of 24 specimens were tested incorporating different fiber types, specimen geometry, and fiber volume fractions of 0.2% and 0.4%: 5 beams and 5 panels containing straight steel fibers; and 6 beams and 8 panels containing ring-type steel fibers. Measurements were made to assess the number of fibers at fractured surfaces of steel fiber reinforced concrete. The developed theoretical expressions reasonably predicted the orientation factor and the number of ring-type steel fibers at failure plane: the average and the standard deviation for the ratios of the test to theory were 1.03 and 0.26, respectively. Theoretical investigations and comparisons were made for the values of orientation factor and the number of fibers at failure plane for straight steel fibers and ring-type steel fibers.

  15. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  16. Rapid Hip Osteoarthritis Development in a Patient with Anterior Acetabular Cyst with Sagittal Alignment Change

    Directory of Open Access Journals (Sweden)

    Yasuhiro Homma

    2014-01-01

    Full Text Available Rapidly destructive coxarthrosis (RDC is rare and develops unusual clinical course. Recent studies suggest multiple possible mechanisms of the development of RDC. However the exact mechanism of RDC is still not clear. The difficulty of the study on RDC is attributed to its rareness and the fact that the data before the onset of RDC is normally unavailable. In this report, we presented the patient having the radiographic data before the onset who had rapid osteoarthritis (OA development after contralateral THA, which meets the current criteria of RDC. We thought that the increased posterior tilt of the pelvis after THA reinforced the stress concentration at pre-existed anterior acetabular cyst, thereby the destruction of the cyst was occurred. As a result the rapid OA was developed. We think that there is the case of rapid osteoarthritis developing due to alternating load concentration by posterior pelvic tilt on preexisting anterior acetabular cyst such as our patient among the cases diagnosed as RDC without any identifiable etiology. The recognition of sagittal alignment changes and anterior acetabular cyst may play important role in prediction and prevention of the rapid hip osteoarthritis development similar to RDC.

  17. Acetabular fractures: anatomic and clinical considerations.

    Science.gov (United States)

    Lawrence, David A; Menn, Kirsten; Baumgaertner, Michael; Haims, Andrew H

    2013-09-01

    Classifying acetabular fractures can be an intimidating topic. However, it is helpful to remember that there are only three basic types of acetabular fractures: column fractures, transverse fractures, and wall fractures. Within this framework, acetabular fractures are classified into two broad categories: elementary or associated fractures. We will review the osseous anatomy of the pelvis and provide systematic approaches for reviewing both radiographs and CT scans to effectively evaluate the acetabulum. Although acetabular fracture classification may seem intimidating, the descriptions and distinctions discussed and shown in this article hopefully make the topic simpler to understand. Approach the task by recalling that there are only three basic types of acetabular fractures: column fractures (coronally oriented on CT images), transverse fractures (sagittally oriented on CT images), and wall fractures (obliquely oriented on CT images). We have provided systematic approaches for reviewing both conventional radiographs and CT scans to effectively assess the acetabulum. The clinical implications of the different fracture patterns have also been reviewed because it is critically important to include pertinent information for our clinical colleagues to provide the most efficient and timely clinical care.

  18. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  19. Total hip reconstruction in acetabular dysplasia : a finite element study

    NARCIS (Netherlands)

    Schüller, H.M.; Dalstra, M.; Huiskes, H.W.J.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  20. Revision of migrated pelvic acetabular components in THA with or without vascular involvement

    Directory of Open Access Journals (Sweden)

    Ștefan Cristea

    2016-05-01

    Full Text Available Purpose. The literature describes a high rate of mortality in cases of intrapelvic acetabular component migration, which is a rare but serious complication. Our aim is to establish and propose a treatment protocol according to our results and experience. Material and Methods. We performed eight (8 total hip revisions with acetabular cup migration between 2006 and 2012. A vascular graft was needed in four (4 of these cases. Two (2 cases were revisions after a spacer for infected arthroplasties. The protocol included the following: X-Ray examination (frontal and lateral views, CT angiography, a biological evaluation, a suitable pre-operative plan, at least six (6 units of blood stock, an experienced anesthesiologist, an experienced surgical team that included a vascular surgeon and a versatile arsenal of revision prostheses, bone grafts and vascular grafts. The anterolateral approach was generally used for hip revisions and the retroperitoneal approach in the dorsal decubitus position was used when vascular risk was involved. Results: The acetabular defect was reconstructed using bone grafts and tantalum revision cups in 4 cases, Burch-Schneider cages in 2 cases, a Kerboull ring in 1 case and a cementless oblong cup (Cotyle Espace in 1 case. In 4 cases, an iliac vessel graft procedure was conducted by the vascular surgeon. All patients survived the revision procedures and returned regularly for subsequent check-ups, during which they did not show any septic complications. Conclusions: Intrapelvic acetabular cup migration is a rare but serious complication that can occur after total hip arthroplasty in either septic or aseptic cases. An experienced, multidisciplinary team of surgeons should be involved in planning and conducting such complicated revisions.

  1. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  2. Efficient radiologic diagnosis of pelvic and acetabular trauma

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Mildenberger, P.; Thelen, M.; Rommens, P.M.

    2000-01-01

    In spite of the widespread availability of CT scanners, conventional X-ray radiographs remain the basic imaging modality in patients with pelvic and/or acetabular trauma. However, the extent of their use will depend on local utilities (e.g., availability of CT scanners) and on the patient's clinical condition. Regarding the inaccuracy of conventional radiography in the diagnosis of injuries of the dorsal pelvic ring and of the acetabulum, computed tomography represents the most important imaging modality in the clinically stable patient. CT provides an exact staging of the extent of trauma and allows for differentiation of pelvic instabilities. CT clearly demonstrates the severity of acetabular trauma and is superior in the detection of local complicating factors, i.e., impressions fractures and (sub-)luxations of the femoral head as well as free intraarticular fragments. CT findings provide the basis for definite treatment regimens of the injured patient. By extension of the examination, all relevant organs and systems (craniospinal, cardiovascular, gastrointestinal, respiratory, genitourinary) can be imaged during one session. The speed of spiral CT scanners and their diagnostic accuracy will play a major role in the management of, especially, polytraumatized patients. The indication for angiography with the option of therapeutic embolization exists if a pelvic bleeding persists even after reposition and operative fixation of the injury. (orig.) [de

  3. Acetabular Dysplasia and Surgical Approaches Other Than Direct Anterior Increases Risk for Malpositioning of the Acetabular Component in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Gromov, Kirill; Greene, Meridith E; Huddleston, James I

    2016-01-01

    BACKGROUND: Persistent acetabular dysplasia (AD) after periacetabular osteotomy has been hypothesized to increase the risk for malpositioning of the acetabular component. In this study, we investigate whether AD is an independent risk factor for cup malpositioning during primary total hip...... arthroplasty (THA). METHODS: Patient demographics, surgical approach, presence of AD assessed using the lateral center-edge angle, and acetabular cup positioning determined using Martell Hip Analysis Suite were investigated in 836 primary THA patients enrolled in a prospective multicenter study. RESULTS: We...

  4. [Quantification of acetabular coverage in normal adult].

    Science.gov (United States)

    Lin, R M; Yang, C Y; Yu, C Y; Yang, C R; Chang, G L; Chou, Y L

    1991-03-01

    Quantification of acetabular coverage is important and can be expressed by superimposition of cartilage tracings on the maximum cross-sectional area of the femoral head. A practical Autolisp program on PC AutoCAD has been developed by us to quantify the acetabular coverage through numerical expression of the images of computed tomography. Thirty adults (60 hips) with normal center-edge angle and acetabular index in plain X ray were randomly selected for serial drops. These slices were prepared with a fixed coordination and in continuous sections of 5 mm in thickness. The contours of the cartilage of each section were digitized into a PC computer and processed by AutoCAD programs to quantify and characterize the acetabular coverage of normal and dysplastic adult hips. We found that a total coverage ratio of greater than 80%, an anterior coverage ratio of greater than 75% and a posterior coverage ratio of greater than 80% can be categorized in a normal group. Polar edge distance is a good indicator for the evaluation of preoperative and postoperative coverage conditions. For standardization and evaluation of acetabular coverage, the most suitable parameters are the total coverage ratio, anterior coverage ratio, posterior coverage ratio and polar edge distance. However, medial coverage and lateral coverage ratios are indispensable in cases of dysplastic hip because variations between them are so great that acetabuloplasty may be impossible. This program can also be used to classify precisely the type of dysplastic hip.

  5. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  6. Modified Harrington Procedure for Acetabular Insuficiency Due to Metastatic Malignant Disease

    Directory of Open Access Journals (Sweden)

    WI Faisham

    2009-05-01

    Full Text Available Extensive peri-acetabular osteolysis caused by malignant disease process is a major surgical challenge as conventional hip arthroplasty is not adequate. We describe a modified use of the Harrington procedure for acetabular insufficiency secondary to metastatic disease in twelve patients. The procedures include application of multiple threaded pins to bridge the acetabular columns, anti-protrusio cage and cemented acetabular cup. Eleven patients were able to walk pain free and achieved a mean Musculoskeletal Tumour Society Functional Score of 80 (range, 68 to 86.

  7. MR imaging findings of acetabular dysplasia in adults

    Energy Technology Data Exchange (ETDEWEB)

    James, Steven; Connell, David [The Royal National Orthopaedic Hospital, Radiology Department, London, Middlesex (United Kingdom); Miocevic, Miranda; Malara, Frank; Pike, Jonathan [Victoria House Hospital, Radiology Department, Melbourne (Australia); Young, David [Melbourne Orthopaedic Group, Orthopaedic Surgery, Melbourne (Australia)

    2006-06-15

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  8. MR imaging findings of acetabular dysplasia in adults

    International Nuclear Information System (INIS)

    James, Steven; Connell, David; Miocevic, Miranda; Malara, Frank; Pike, Jonathan; Young, David

    2006-01-01

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  9. Image research on acetabular teardrop shadow by X-ray plain-film and CT

    International Nuclear Information System (INIS)

    Wang Xiaoxuan; Zhai Yuejie; Yu Hongguang; Yang Yijun; Zhang Daiwei; Chen Aili; Song Quanjun

    2001-01-01

    Objective: To evaluate the anatomical structure of bone in the formation of acetabular teardrop shadow. Methods: The acetabular teardrop shadow of the X-ray plain-film in 100 children and 300 adults, and of CT in 43 cases were analysed, measured and compared. Results: In children, teardrop shadow appeared 'U' in 80.00%, 14.00% in teardrop, 6.00% in line. In adult teardrop shadow appeared 'U' in 41.33%, 53.33% in teardrop, 5.34% in line. There were significant differences between children and adult in the frequency of 'U' and teardrop (x 2 = 43.34, P 2 = 45.62, P < 0.01). In children, inpeduncle of teardrop shadow was formed of middle 1/3 substantia-line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 substantia-line of bottom of acetabular. In adult, inpeduncle was formed of middle 1/3 or back 1/3 substantia line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 or back 1/3 substantia-line of bottom of acetabular. Conclusion: In children, acetabular teardrop shadow was mainly formed of middle 1/3 bone of acetabular concavity. In adult, middle 1/3 or back 1/3 bone of acetabular concavity contribute to the shadow. The ahead 1/3 bone of acetabular concavity is not involved

  10. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  11. Development of high-speed reactive processing system for carbon fiber-reinforced polyamide-6 composite: In-situ anionic ring-opening polymerization

    International Nuclear Information System (INIS)

    Kim, Sang-Woo; Seong, Dong Gi; Yi, Jin-Woo; Um, Moon-Kwang

    2016-01-01

    In order to manufacture carbon fiber-reinforced polyamide-6 (PA-6) composite, we optimized the reactive processing system. The in-situ anionic ring-opening polymerization of ε-caprolactam was utilized with proper catalyst and initiator for PA-6 matrix. The mechanical properties such as tensile strength, inter-laminar shear strength and compressive strength of the produced carbon fiber-reinforced PA-6 composite were measured, which were compared with the corresponding scanning electron microscope (SEM) images to investigate the polymer properties as well as the interfacial interaction between fiber and polymer matrix. Furthermore, kinetics of in-situ anionic ring-opening polymerization of ε-caprolactam will be discussed in the viewpoint of increasing manufacturing speed and interfacial bonding between PA-6 matrix and carbon fiber during polymerization.

  12. Development of high-speed reactive processing system for carbon fiber-reinforced polyamide-6 composite: In-situ anionic ring-opening polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang-Woo; Seong, Dong Gi; Yi, Jin-Woo; Um, Moon-Kwang [Composites Research Division, Korea Institute of Materials Science (KIMS), Changwon, Gyeongnam, 642–831 (Korea, Republic of)

    2016-05-18

    In order to manufacture carbon fiber-reinforced polyamide-6 (PA-6) composite, we optimized the reactive processing system. The in-situ anionic ring-opening polymerization of ε-caprolactam was utilized with proper catalyst and initiator for PA-6 matrix. The mechanical properties such as tensile strength, inter-laminar shear strength and compressive strength of the produced carbon fiber-reinforced PA-6 composite were measured, which were compared with the corresponding scanning electron microscope (SEM) images to investigate the polymer properties as well as the interfacial interaction between fiber and polymer matrix. Furthermore, kinetics of in-situ anionic ring-opening polymerization of ε-caprolactam will be discussed in the viewpoint of increasing manufacturing speed and interfacial bonding between PA-6 matrix and carbon fiber during polymerization.

  13. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  14. Acetabular labral tears in patients with sports injury.

    Science.gov (United States)

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  15. Plain film analysis of acetabular fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik Hospital, Pusan (Korea, Republic of)

    1986-02-15

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%)

  16. Plain film analysis of acetabular fracture

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1986-01-01

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%).

  17. STUDY ON ANTI-CRACKING PERFORMANCE EVALUATION METHOD OF STEEL FIBER REINFORCED CERAMSITE CONCRETE (SFRCC BASED ON PARTLY-RESTRAINED SHRINKAGE RING

    Directory of Open Access Journals (Sweden)

    Zhang Yi-fan

    2017-12-01

    Full Text Available In the study of crack resistance of steel fiber reinforced concrete in steel fiber on concrete deformation ability and prevent the Angle of the micro cracks, and the lack of overall evaluation on the performance of steel fiber reinforced concrete crack. By tinder barrier-free restrain some experimental research on steel fiber ceramsite concrete shrinkage ring crack resistance, and use the test results within the definition of steel ring strain from expansion to contraction cut-off age for early and late ages, and the ages of the cut-off point for the early and the late steel fiber ceramsite concrete anti-cracking performance evaluation. The results show that the anti-cracking properties of the steel fiber ceramic concrete are improved with the increase of steel fiber content.

  18. The nerve endings of the acetabular labrum.

    Science.gov (United States)

    Kim, Y T; Azuma, H

    1995-11-01

    The nerve endings of the human acetabular labrum were investigated. Twenty-three acetabular labra were obtained from 24 fresh human cadavers, stained with Suzuki's silver impregnation and an immunohistochemical technique for neurogenic specific protein S-100, and examined by light and electron microscopy. Ramified free nerve endings were seen in all specimens by silver staining, and also were observed by the immunohistochemical technique for S-100 protein. Sensory nerve end organs, such as a Vater-Pacini corpuscle, Golgi-Mazzoni corpuscle, Ruffini corpuscle, and articular corpuscle (Krause corpuscle), were observed by silver staining. Collagen fibers were scattered sparsely in the superficial layer of the labrum, and nerve endings were observed mostly in this region. Collagen fibers were sparse, and nerve endings also were observed in some regions among the collagen fiber bundles in the inner layer. Innervation of the acetabular labrum was confirmed in this study, suggesting that nerve endings in the labrum may be involved in nociceptive and proprioceptive mechanisms.

  19. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  20. Acetabular paralabral cyst causing compression of the sciatic nerve

    Directory of Open Access Journals (Sweden)

    Caoimhe Byrne, MB BCh BAO

    2017-12-01

    Full Text Available Acetabular paralabral cysts are common. They vary in their clinical presentation and may be asymptomatic or cause pain and restriction at the hip joint. In rare instances they may cause symptoms by compressing local neurovascular structures. We report a case of symptomatic compression of the sciatic nerve by a posteriorly displaced acetabular paralabral cyst.

  1. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  2. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  3. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  4. Acetabular paralabral cyst: an uncommon cause of sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, P.M.; Sanders, T.G. [Department of Radiology, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States); Matchette, M.W. [University of Texas Medical School, 7703 Floyd Curl Drive, San Antonio, TX 78229-3900 (United States); Parsons, T.W. [Department of Orthopedic Surgery, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States)

    2003-02-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  5. Acetabular paralabral cyst: an uncommon cause of sciatica

    International Nuclear Information System (INIS)

    Sherman, P.M.; Sanders, T.G.; Matchette, M.W.; Parsons, T.W.

    2003-01-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  6. CUSTOM TRIFLANGE ACETABULAR COMPONENTS IN REVISION HIP REPLACEMENT (EXPERIENCE REVIEW

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2017-01-01

    Full Text Available Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months. 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.

  7. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro [Asahikawa Medical College, Department of Orthopaedic Surgery, Asahikawa (Japan); Minami, Akio [Hokkaido University School of Medicine, Department of Orthopaedic Surgery, Sapporo (Japan)

    2009-02-15

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  8. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro; Minami, Akio

    2009-01-01

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  9. Acetabular fractures: what radiologists should know and how 3D CT can aid classification.

    Science.gov (United States)

    Scheinfeld, Meir H; Dym, Akiva A; Spektor, Michael; Avery, Laura L; Dym, R Joshua; Amanatullah, Derek F

    2015-01-01

    Correct recognition, description, and classification of acetabular fractures is essential for efficient patient triage and treatment. Acetabular fractures may result from high-energy trauma or low-energy trauma in the elderly. The most widely used acetabular fracture classification system among radiologists and orthopedic surgeons is the system of Judet and Letournel, which includes five elementary (or elemental) and five associated fractures. The elementary fractures are anterior wall, posterior wall, anterior column, posterior column, and transverse. The associated fractures are all combinations or partial combinations of the elementary fractures and include transverse with posterior wall, T-shaped, associated both column, anterior column or wall with posterior hemitransverse, and posterior column with posterior wall. The most unique fracture is the associated both column fracture, which completely dissociates the acetabular articular surface from the sciatic buttress. Accurate categorization of acetabular fractures is challenging because of the complex three-dimensional (3D) anatomy of the pelvis, the rarity of certain acetabular fracture variants, and confusing nomenclature. Comparing a 3D image of the fractured acetabulum with a standard diagram containing the 10 Judet and Letournel categories of acetabular fracture and using a flowchart algorithm are effective ways of arriving at the correct fracture classification. Online supplemental material is available for this article. (©)RSNA, 2015.

  10. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  11. Optimization of technique for insertion of implants at the supra-acetabular corridor in pelvis and acetabular surgery.

    Science.gov (United States)

    Tosounidis, Theodoros H; Mauffrey, Cyril; Giannoudis, Peter V

    2018-01-01

    The technique for application of implants at the sciatic buttress has been well described in the pelvic and acetabular fracture reconstruction literature. We described a new use of the inlet-obturator oblique view for the identification of the anterior inferior iliac spine, which is the entry point of implants, and we provide a detailed fluoroscopic and radiographic description of this view. A small series of 15 patients who underwent an application of an anterior inferior pelvic external (supra-acetabular) fixator via this technique is presented. We consider the use of the obturator oblique for the identification of the entry point unnecessary, and we advocate for the use of only the inlet-obturator oblique and iliac oblique views when implants are applied to the sciatic buttress.

  12. Numerical analysis on seismic behavior of reinforced concrete beam to concrete filled steel tubular column connections with ring-beam

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yi., E-mail: zhaoyi091218@163.com [School of Civil and Architectural Engineering, Zhongyuan University of Technology,Zhengzhou 450000 (China); Xu, Li. Hua. [School of Civil Engineering, Wuhan University, No.8, Donghu Road, WuHan 430072 (China)

    2016-06-08

    This paper presents numerical study of the seismic behavior of reinforced concrete beam to concrete filled steel tube column connections with ring-beam. The material stress-strain relations, element type and boundary condition are selected, which are consistent with actual situation. Then the seismic behavior of this type of joint are researched by ABAQUS, and finite element analyses are conducted under cyclic loading. Its parameters are discussed including thickness of steel tubular column wall, sectional dimension of the ring-beam and strength of the core concrete. The results show that the ultimate capacity of the connections is improved with sectional dimension of the ring-beam increased. In the meanwhile, the influence on skeleton curve of the joints is slight of which included thickness of steel tubular column wall and strength of the core concrete.

  13. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  14. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    Science.gov (United States)

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum.

  15. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  16. The Use of a Supra-Acetabular Antibiotic-Loaded Cement Shelf to Improve Hip Stability in First-Stage Infected Total Hip Arthroplasty.

    Science.gov (United States)

    Drexler, Michael; Kuzyk, Paul R T; Koo, Kevin; Gross, Allan E; Kosashvili, Yona; Reischl, Nickola; Rutenberg, Tal Frenkel; Safir, Oleg

    2016-11-01

    Antibiotic-loaded cement spacers in first-stage revision total hip arthroplasty (THA) for managing infection are associated with high dislocation and fracture rates. The aim of this study was to report the use of an antibiotic-loaded cemented supra-acetabular roof augmentation to reinforce hip stability after cement spacer insertion for first-stage total hip revision in the treatment of infected THA. We retrospectively reviewed a consecutive series of 50 THAs involving 47 patients with an infected hip requiring staged revisions of THA. We documented dislocation, reinfection, and time for revision and outcome. There were no cases of hip dislocation, cement fractures, or any other technical complications associated with the use of the roof augmentation lip. Thirteen cases (26%) had a cemented spacer for longer than 120 days. Seven (14%) cases had recurrent infection after staged revision THA. The antibiotic-loaded cemented supra-acetabular roof augment improved femoral head spacer coverage for patients requiring a staged revision THA for infection. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    Science.gov (United States)

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  18. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  19. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    International Nuclear Information System (INIS)

    Aly, Abdel Rahman; Rajasekaran, Sathish; Obaid, Haron

    2013-01-01

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  20. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Abdel Rahman [University of Saskatchewan, Department of Physical Medicine and Rehabilitation, Saskatoon, SK (Canada); Saskatoon City Hospital, Saskatoon, SK (Canada); Rajasekaran, Sathish [HealthPointe, Pain, Spine and Sport Medicine, Alberta (Canada); Obaid, Haron [Royal University Hospital, University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada)

    2013-09-15

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  1. Acetabular roof stress fracture: a rare cause of hip pain in children ...

    African Journals Online (AJOL)

    Stress fracture of acetabular roof is an unusual cause of hip pain. It is considered as an underdiagnosed entity. People who are more susceptible to experience this fracture are athletes, soldiers and dancers. We present the case of an 11 year old girl with a roof acetabular stress fracture for which the diagnosis and ...

  2. Cement-in-cement acetabular revision with a constrained tripolar component.

    Science.gov (United States)

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  3. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Christophe Boulay

    2014-01-01

    Full Text Available Acetabular cup orientation (inclination and anteversion is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter could determine the safe range of pelvis tilt (positional parameter for an individual and not a group.

  4. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects.

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. IV.

  5. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  6. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    Science.gov (United States)

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  7. Measurement of acetabular morphology under three-dimensional reconstruction of CT and significance

    International Nuclear Information System (INIS)

    Han Yingying; Yang Qiwei; Lai Ying; Hao Shuang; Ma Hecheng; Xiao Chengshuang; Li Youqiong

    2011-01-01

    Objective: To measure the acetabular morphology of Chinese on CT three-dimensional (3D) reconstruction image, and provide the evidence on the prevention and treatment of hip disease. Methods: 96 cases (192 sides) of adult hip CT scans were reconstructed, the acetabular index (AA), center-edge (CE), ACE angle, anteversion angle (AVA), abduction angle (ABA), and vertical diameter (SID) were measured. Results: The total acetabular index was (8.78±5.34)°, of which male was (7.84±5.55)° and female was (9.60±5.06)°. The total CE was (33.59±5.91)°, of which male was (34.55±6.03)° and female was (32.78±5.70)°. The total ACE angle was (29.01±5.65)°, of which male was (28.02±5.94)° and female was (29.80±5.30)°. The total AVA was (20.92±5.55)°, of which male was (20.48±5.08)° and female was (21.25±5.89)°. The total ABA was (51.27±4.16)°, of which male was (51.71±4.37)° and female was (50.89±3.96)°. The total SID was (53.79±3.92) mm, of which male was (56.55±2.64) mm and female was (51.46±3.25) mm. Of the above data, there were statistical differences in the acetabular index, CE angle, ACE angle and acetabular diameter between men and women (P<0.05), Chinese and foreigners (P<0.05). While there was no statistical difference between the left and right sides (P>0.05). Conclusion: There are differences in acetabular morphology between men and women, Chinese and foreigners. Compared with simply using overseas data, it is better to study morphological parameters of native acetabula to instruct the preoperative preparation and operation of national total hip arthroplasty surgery. And it is meaningful to design national parameters. (authors)

  8. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Summary Background Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Materials and methods Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. Results FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. Conclusion FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. Level of evidence IV. PMID:29264339

  9. Digestive Fistula Due to Acetabular Protrusion: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Carlos Marqués

    2017-12-01

    Full Text Available Intrapelvic migration of the acetabular component after primary or revision hip arthroplasty is a rare complication. We present a case of an intrapelvic migration of the acetabular component after a revision hip arthroplasty which led to an enteric fistula to the hip joint as well as to a sigmoid colon perforation.

  10. Surgical Site Infection Following Fixation of Acetabular Fractures.

    Science.gov (United States)

    Iqbal, Faizan; Younus, Sajid; Asmatullah; Zia, Osama Bin; Khan, Naveed

    2017-09-01

    Acetabular fractures are mainly caused by high energy trauma. Surgical fixation of these fractures requires extensive surgical exposure which increases the length of operation and blood loss as well. This may increase the risk of surgical site infection. Our aim is to evaluate the prevalence of surgical site infections and the risk factors associated with it so as to minimize its chances. A total of 261 patients who underwent acetabular fracture surgery were retrospectively reviewed. Patients were divided into 2 groups, with or without surgical site infection. Factors examined include patients' gender, age, body mass index (BMI), time between injury and surgery, operative time, estimated blood loss, number of packed red blood cell transfused, length of total intensive care unit (ICU) stay, fracture type, surgical approach, smoking status, patients' comorbids and associated injuries. Fourteen patients (5.4%) developed surgical site infection. Out of 14 infections, 4 were superficial and 10 were deep. The factors that were found to be associated with surgical site infection following acetabular fracture fixation were prolonged operation time, increased BMI, prolonged ICU stay, larger amount of packed red blood cell transfused and associated genitourinary and abdominal trauma. In our study, we conclude that measures should be undertaken to attenuate the chances of surgical site infection in this major surgery by considering the risk factors significantly associated with it.

  11. Surgical Stabilization of Pelvic and Acetabular Fractures: A Review on the Determinants of Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    SS Sathappan

    2010-03-01

    Full Text Available AIM: Pelvic and acetabular fractures are associated with high-energy trauma. The aim of this study was to identify factors that are associated with specific clinical outcomes following treatment for these fractures. METHODS: A consecutive series of 30 patients who had surgical intervention for either pelvic or acetabular fractures formed the sample for this study. Clinical variables reviewed were: age, associated injuries, number of surgical procedures, time to surgery and post-operative complications. Clinical outcomes were assessed using Matta’s grading of post- operative fracture reduction alignment, and functional outcomes were graded using D'Aubigne & Postel’s Hip scoring system. RESULTS: Study subjects included twelve pelvic fractures and eighteen acetabular fractures. Patients older than 50 years of age had poorer hip scores despite surgery. Earlier fracture fixation (within five days was associated with better hip scores. Patients with acetabular fractures generally had better functional outcomes than patients with pelvic fractures (mean hip score 15.0 vs. 13.5. Closer anatomical reduction of acetabular fractures was associated with better functional outcome. CONCLUSION: Improved clinical outcomes are associated with younger age, fewer concomitant injuries, shorter time interval to surgery and more closely approximated anatomical fracture reduction.

  12. Assessment of trochanteric osteotomy fragment union after acetabular fracture surgery.

    Science.gov (United States)

    Dubina, Andrew G; Wickramaratne, Niluka; O'Toole, Robert V; Manson, Theodore T

    2017-02-01

    Trochanteric osteotomies are performed in conjunction with standard approaches to improve surgical exposure during open reduction and internal fixation (ORIF) of acetabular fractures. The literature on total hip arthroplasty reports nonunion rates as high as 30% associated with trochanteric osteotomies; however, few data exist regarding the outcomes of trochanteric osteotomies for acetabular fracture surgery. Our hypotheses were 1) patients receiving trochanteric osteotomies during ORIF of acetabular fractures have a low rate of nonunion of the osteotomy fragment, and 2) hip abduction precautions are not necessary with digastric type osteotomies. A retrospective review was conducted to identify patients with acetabular fractures between July 2002 and June 2010 (n=734 fractures) who required trochanteric osteotomies (n=64, 9% of fractures). Forty-seven met inclusion criteria of adequate follow-up (>56days). No excluded patient experienced a complication. Fractures were classified using the Letournel-Judet classification system. Only seven (20%) of 35 patients who received digastric osteotomies had hip abduction precautions applied during the postoperative period. All study patients were shown to have radiographic union at the trochanteric osteotomy site (100% union rate, n=47). Hip abduction precautions intended to protect the osteotomy site and reduce the risk of nonunion and fixation failure were infrequently applied to patients with digastric osteotomies (20%) in this cohort. Multiple protective factors against nonunion were present in this study population compared with previous arthroplasty studies from other institutions. Trochanteric osteotomies are not associated with a significant nonunion rate, and digastric osteotomies might be safely managed without hip abduction precautions. Copyright © 2016. Published by Elsevier Ltd.

  13. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  14. Cemented total hip replacement cable debris and acetabular construct durability.

    Science.gov (United States)

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  15. Radiological landmarks for the safe extra-capsular placement of supra-acetabular half pins for external fixation.

    Science.gov (United States)

    Lidder, Surjit; Heidari, Nima; Gänsslen, Axel; Grechenig, Wolfgang

    2013-03-01

    Low anterior external fixators are constructed by placing half pins in the dense bone tunnel of the supra-acetabular region in an anterior to posterior direction. Although the placement of these pins is extra-articular, they may still breach the hip capsule on the anterior inferior iliac spine and thus be intra-capsular. We aim to provide radiological markers for the most superior fibres of the capsule to allow safe extra-capsular pin placement within the supra-acetabular bone tunnel. Thirteen cadaveric pelves were used for this study. The supra-acetabular bone tunnel was visualised with an image intensifier. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images. Once all images were acquired they were calibrated and analysed to estimate the dimensions of the supra-acetabular bone tunnel and the reflection of the hip capsule. The median height of the bone tunnel was 23.6 mm (18.9-33.2) and maximum width was 11.4 mm (7.6-16.3). The inferior margin of the bone tunnel was 6.7 mm (1.1-14.5) superior to the acetabular dome, and the most proximal fibres of the capsule were 9.3 mm (4.7-6.1) superior to the acetabular dome. The inferior portion of the tunnel was 3.7 mm (0.3-8.9) within the joint. Half pins for the construction of a pelvic external fixator should be placed in the upper half of the supra-acetabular bone corridor to minimise the risk of intra-capsular placement.

  16. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  17. Minimum ten-year follow-up of acetabular fracture fixation from the Irish tertiary referral centre.

    LENUS (Irish Health Repository)

    Magill, Paul

    2012-04-01

    Successful outcome from acetabular fracture fixation is multi-factorial. Long-term results are not frequently reported. Pooling such data from high output centres will help progress acetabular fixation. This paper presents the first ten-year data from the Irish tertiary referral centre.

  18. Acetabular labrum of hip joint in osteoarthritis: A qualitative original study and short review of the literature.

    Science.gov (United States)

    Kapetanakis, S; Dermon, A; Gkantsinikoudis, N; Kommata, V; Soukakos, P; Dermon, C R

    2017-01-01

    Histological architecture of normal acetabular labrum regarding free nerve endings (FNEs) and mechanoreceptors (MRs) has been satisfactorily described in the literature. However, the presence of FNEs and MRs in acetabular labrum of hip joint has been analyzed only once in patients with osteoarthritis (OA). Aim of this article is to report histological distribution pattern of FNEs and MRs in acetabular labrum of patients with severe OA, at the same time conducting a comparison with normal acetabular labrum described in the literature. Seven patients with severe hip OA were enrolled in this study. Patient selection was assisted by the utilization of specific clinical scales delineated by the American College of Rheumatology. After successful total hip arthroplasty, tissue samples of acetabular labra of seven patients were histologically processed and stained with the gold standard chloride method, which was subsequently examined under a compound microscope. FNEs and MRs constituted the major histological structures. Identified MRs included Pacini corpuscles, Ruffini corpuscles, and Golgi-Mazzoni corpuscles. The presence of FNEs was predominant in the middle part of the acetabular labrum, featuring a remarkable decrease in peripheral parts. In contrast, MRs were detected basically in peripheral parts and less in the middle part. Differentiation of the distribution pattern of MRs and FNEs in acetabular labrum of hip joint is remarkable between normal patients and patients with severe OA. The abundance of FNEs in the middle part of the pathologic labrum is mainly responsible for the observed discrimination. A "conversion" of MRs to FNEs may occur during OA progression, modulating therefore this pattern as well as the upcoming clinical manifestations.

  19. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    Science.gov (United States)

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  20. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Fischer, U.; Vosshenrich, R.

    1993-01-01

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.) [de

  1. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    Science.gov (United States)

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  2. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    Science.gov (United States)

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Posterior trochanteric osteotomy in acetabular fractures for 32 cases.

    Science.gov (United States)

    Niu, Yunfei; An, Xiaofei; Xu, Shuogui; Wu, Dajiang; Zhang, Chuncai; Li, Ming

    2014-11-01

    The aim of this study is to explore the method and clinical outcome of posterior trochanteric osteotomy in acetabular fractures. From January 2000 to January 2008, 32 cases of acetabular fractures involving the dome of acetabulum underwent posterior trochanteric osteotomy for a better exposure and internal fixation with acetabular tridimensional memory fixation system. 28 cases (16 men and 12 women, mean age 39.9 years, range 16-73 years) were followed up with an average of 48.9 months (range of 19-95 months) and four were lost during follow up. Of 28 cases, 19 were fresh fractures and 9 were old fractures. The reduction was evaluated with Matta criteria. Clinical evaluation was based on modified Merle d'Aubigne and Postel scoring. Motor strength of the abductors was evaluated according to the Medical Research Council grading system. Ectopic ossification was classified according to Brooker criteria. Anatomical reduction was achieved in 17 cases and satisfied reduction in 10 patients. Poor reduction happened in an old fracture. All acetabular fractures got a direct bone union and no displacement and deep infection occurred. All osteotomies healed within 3.5 months without any nonunion, proximal migration of the greater trochanter, loosing or broken of instrumentation, and deep infection. Two superficial infections were healed with a regular dressing. Two patients underwent removal of implants from greater trochanter because of irritation. The strength of the abductors was of Grade 3/5 in two patients, Grade 4/5 in five patients, and normal in the rest. Clinical scoring was excellent to good in 84 %. Ectopic ossification occurred in five patients, grade 1 in two patients, grade 2 in two, and grade 3 in one. But function of hip joint was not seriously affected. Posterior trochanteric osteotomy can provide an adequate exposure of the dome of acetabulum without the associated complications like nonunion, proximal replacement, and weak of the abductors which often occur

  4. Does Increased Coefficient of Friction of Highly Porous Metal Increase Initial Stability at the Acetabular Interface?

    Science.gov (United States)

    Goldman, Ashton H; Armstrong, Lucas C; Owen, John R; Wayne, Jennifer S; Jiranek, William A

    2016-03-01

    Highly porous metal acetabular components illustrate a decreased rate of aseptic loosening in short-term follow-up compared with previous registry data. This study compared the effect of component surface roughness at the bone-implant interface and the quality of the bone on initial pressfit stability. The null hypothesis is that a standard porous coated acetabular cup would show no difference in initial stability as compared with a highly porous acetabular cup when subjected to a bending moment. Second, would bone mineral density (BMD) be a significant variable under these test conditions. In a cadaveric model, acetabular cup micromotion was measured during a 1-time cantilever bending moment applied to 2 generations of pressfit acetabular components. BMD data were also obtained from the femoral necks available for associated specimen. The mean bending moment at 150 μm was not found to be significantly different for Gription (24.6 ± 14.0 N m) cups vs Porocoat (25 ± 10.2 N m; P > .84). The peak bending moment tolerated by Gription cups (33.9 ± 20.3 N m) was not found to be significantly different from Porocoat (33.5 ± 12.2 N m; P > .92). No correlation between BMD and bending moment at 150 μm of displacement could be identified. The coefficient of friction provided by highly porous metal acetabular shells used in this study did not provide better resistance to migration under bending load when compared with a standard porous coated component. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  6. Increased Mortality in Elderly Patients with Sarcopenia and Acetabular Fractures.

    Science.gov (United States)

    Deren, Matthew E; Babu, Jacob; Cohen, Eric M; Machan, Jason; Born, Christopher T; Hayda, Roman

    2017-02-01

    Sarcopenia is a condition of clinically relevant loss of muscle mass and function. Acetabular fractures in elderly patients are common and difficult to treat. This study aimed to determine if sarcopenia is common in elderly patients with acetabular fractures and correlates with lower-energy mechanisms of injury, higher rates of complications, and higher mortality than patients with normal muscle mass. The Rhode Island Hospital Trauma Database was queried for patients who were ≥60 years of age from 2005 to 2014 using the International Classification of Diseases, Ninth Revision, code for closed acetabular fracture, 808.0. Charts were retrospectively reviewed for demographic data, operative intervention, mechanism of injury, mortality, comorbidities, and other factors. Computed tomography (CT) was used to determine the muscle cross-sectional area and to calculate the skeletal muscle index. The database revealed 192 patients coded for acetabular fracture; of these, 181 were correctly diagnosed. Ninety-nine patients had recorded body mass index (BMI) and adequate CT scans to measure the skeletal muscle index. Forty-two patients (42.4%) had sarcopenia, and 57 patients (57.6%) did not have sarcopenia. There were no significant differences in demographic characteristics between the groups with the exception of BMI and sex. BMI was higher in patients who did not have sarcopenia (31.7 kg/m) than it was in patients with sarcopenia (23.6 kg/m) (p sarcopenia at 76.2% (32 of 42 patients) than in patients without sarcopenia at 50.9% (29 of 57 patients). Fractures in patients without sarcopenia were associated with a higher-energy mechanism of injury in 78.9% of cases compared with 52.4% of cases of patients with sarcopenia (p = 0.005). Sarcopenia was significantly associated (p = 0.0419) with increased 1-year mortality (28.6%) compared with the absence of sarcopenia (12.3%). This association was even stronger if in-hospital mortality was excluded (p = 0.00074). Finally

  7. Acetabular fractures following rugby tackles: a case series

    LENUS (Irish Health Repository)

    Good, Daniel W

    2011-10-05

    Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old) who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting \\'the tackle\\' to only two players may well reduce the likelihood of this life-altering injury.

  8. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  9. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular...

  10. Cranial acetabular retroversion is common in developmental dysplasia of the hip as assessed by the weight bearing position

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mikkelsen, Lone Rømer; Jacobsen, Steffen

    2010-01-01

    The appearance of acetabular version differs between the supine and weight bearing positions in developmental dysplasia of the hip. Weight bearing radiographic evaluation has been recommended to ensure the best coherence between symptoms, functional appearance, and hip deformities. Previous...... prevalence estimates of acetabular retroversion in dysplastic hips have been established in radiographs recorded with the patient supine and with inclusion only if pelvic tilt met standardized criteria. We assessed the prevalence and the extent of acetabular retroversion in dysplastic hip joints in weight...

  11. [Pelvic reconstructions after bone tumor resection].

    Science.gov (United States)

    Anract, Philippe; Biau, David; Babinet, Antoine; Tomeno, Bernard

    2014-02-01

    The three more frequent primitive malignant bone tumour which concerned the iliac bone are chondrosarcoma, following Ewing sarcoma and osteosarcoma. Wide resection remains the most important part of the treatment associated with chemotherapy for osteosarcoma and the Ewing sarcoma. Iliac wing resections and obdurate ring don't required reconstruction. However, acetabular resections and iliac wing resection with disruption of the pelvic ring required reconstruction to provide acceptable functional result. Acetabular reconstruction remains high technical demanding challenge. After isolated acetabular resection or associated to obdurate ring, our usual method of reconstruction is homolateral proximal femoral autograft and total hip prosthesis but it is possible to also used : saddle prosthesis, Mac Minn prosthesis with auto or allograft, modular prosthesis or custom made prosthesis, massive allograft with or without prosthesis and femoro-ilac arthrodesis. After resection of the iliac wing plus acetabulum, reconstruction can be performed by femoro-obturatrice and femora-sacral arthrodesis, homolateral proximal femoral autograft and prosthesis, femoral medialisation, massive allograft and massive allograft. Carcinological results are lesser than resection for distal limb tumor, local recurrence rate range 17 to 45%. Functional results after Iliac wing and obdurate ring are good. However, acetabular reconstruction provide uncertain functional results. The lesser results arrive after hemipelvic or acetabular and iliac wing resection-reconstruction, especially when gluteus muscles were also resected. The most favourable results arrive after isolated acetabular or acetabular plus obturateur ring resection-reconstruction.

  12. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    Science.gov (United States)

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    Science.gov (United States)

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  15. Acetabular retroversion as a rare cause of chronic hip pain: recognition of the ''figure-eight'' sign

    Energy Technology Data Exchange (ETDEWEB)

    Banks, Kevin P. [Brooke Army Medical Center, Department of Radiology, Fort Sam Houston, TX (United States); Grayson, David E. [Wilford Hall Medical Center, Department of Radiology, Lackland Air Force Base, TX (United States)

    2007-06-15

    While well-recognized in the orthopedic literature as a cause of chronic hip pain, acetabular retroversion has not been specifically described in the radiologic literature. Acetabular retroversion represents a particular form of hip dysplasia characterized by abnormal posterolateral orientation of the acetabulum. This pathophysiology predisposes the individual to subsequent anterior impingement of the femoral neck upon the anterior acetabular margin and fibrous labrum. Without treatment, cases may progress to damage of the anterior labrum and cartilage, with eventual early onset of osteoarthritic disease. This impinging condition has been described as occurring in isolation or as part of a complex dysplasia. We describe two cases of acetabular retroversion diagnosed by conventional radiographic evaluation of the pelvis, one in isolation and one occurring in the setting of a larger congenital syndrome. These cases illustrate the utility of the ''figure-eight'' sign in identifying abnormalities of acetabular version and thus assisting clinicians in properly identifying these individuals so that appropriate therapy may be instituted. (orig.)

  16. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    International Nuclear Information System (INIS)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide

    2012-01-01

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  17. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan)

    2012-11-15

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  18. Determinación del desgaste del componente acetabular en prótesis totales de cadera. // Wear determination of acetabular component in total hip prosthesis.

    Directory of Open Access Journals (Sweden)

    G. García del Pino

    2002-01-01

    Full Text Available En este trabajo se realiza un estudio a través del Método de los Elementos Finitos “MEF” sobre el desgaste del componenteacetabular durante el ciclo de marcha y considerando algunos casos extremos de cargas como subir y bajar escaleras,levantarse de una silla, etc. Utilizando el MEF fueron modelados independientemente los componentes acetabular yfemoral de la prótesis total de cadera y puestos en contacto posteriormente. Fueron estudiadas varias posiciones delacetábulo así como diferentes casos de carga simulando pacientes con diferente peso corporal y actividades físicas. Paraevaluar los resultados se crearon rutinas en lenguaje C que organizaron los mismos para un tratamiento estadísticoposterior.Palabras claves: biomecánica, ortopedia, elementos finitos, modelación, desgaste, prótesis de cadera.___________________________________________________________________________Abstract.A wear study of acetabular component during the marching cycle, considering some extreme loads cases as: ascend anddescend stairways, get up from a seat, etc , by means of Finite Elements Method ( FEM , is carried out. The acetabular andfemoral component of the total hip prosthesis were independently modeled and placed in contact lastly. Several acetabulpositions were studied as well as different load cases, simulating patients with different body weight and different physicalactivities. To evaluate the results routines in C language were created in order to organized the same ones for a laterstatistical treatment.Key words. biomechanics, ortophedy, finite elements, modelation, wear, hip bone prosthesis.

  19. Prophylactic post-operative radiotherapy prevents heterotopic ossification following traumatic acetabular fracture

    International Nuclear Information System (INIS)

    Meyer, Joseph T.; Hixson, William C.; Jennelle, Richard L. S.; Alonso, Jorge E.; Raben, David; Spencer, Sharon S.; Kim, Robert Y.

    1996-01-01

    Purpose/Objective: To determine the effect of post-operative radiation on the incidence of heterotopic ossification following traumatic acetabular fracture. Materials and Methods: A retrospective analysis was performed of the medical records and radiographs of all patients who received prophylactic radiotherapy to prevent heterotopic ossification. These results were compared to a similar group of patients receiving no prophylactic radiotherapy following traumatic acetabular fracture. Between 1987 and 1994, sixty-six patients received prophylactic radiotherapy to prevent heterotopic ossification. Results: Thirty-six patients (55%) received radiotherapy following operative repair of a traumatic acetabular fracture (median follow-up: 210 days). Three dose schedules were utilized: (28(36)) (77.8%) received 700 cGy/1 fx, (2(36)) (5.5%) 800 cGy/1 fx, and (6(36)) (16.7%) 1000 cGy/5 fxs. These patients were retrospectively compared with thirty-four patients who received similar operative management of traumatic acetabular fractures without post-operative radiotherapy (median follow-up: 378 days). Of the patients with heterotopic ossification, 96% developed it within 180 days. Complications and delayed wound healing rates were not significantly different in patients treated with or without post-operative radiotherapy, 6.4% and 6.3% respectively (p=0.49). The incidence of heterotopic ossification at last follow-up in patients treated with and without post-operative radiotherapy was (5(36)) (13.9%) and (19(34)) (55.9%), respectively (p=0.000332). For all patients, type of surgical approach was associated with development of heterotopic ossification: posterior, (7(38)) (18.4%), ilio-inguinal (1(3)) (33.3%), tri-radiate (13(19)) (68.4%), p=.000511. In patients receiving post-operative radiotherapy, variables associated with heterotopic ossification included dose (p=.00962), injury-to-radiation interval (p=.0038), and surgery-to-radiation interval (p=.0238). Fifty percent ((3

  20. MR-arthrography of the acetabular labrum - radiologic-pathologic correlation in 20 cadaveric hip joints; MR-Arthrographie des Labrum acetabulare - Radiologisch-anatomische Korrelation an 20 Leichenhueften

    Energy Technology Data Exchange (ETDEWEB)

    Brossmann, J.; Steffens, J.C.; Heller, M. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie; Ploetz, G.M.J.; Hassenpflug, J. [Kiel Univ. (Germany). Klinik fuer Orthopadie

    1999-08-01

    Purpose: To investigate frequency of acetabular labral lesions in elderly hip joints, and to determine sensitivity and specificity of MR arthrography (MRa) for the detection of these abnormalities. Materials and Methods: Twenty cadaveric hip joints were examined by MRa. For MRa, 15 ml of a solution of iodinated contrast solution (Solutrast 300) and Gd-DTPA (100:1) were injected under fluoroscopic guidance. MR imaging was performed on a 1.5 TM scanner (Vision, Siemens; FOV 16 cm, matrix 256x256, fat-suppressed 3D-FLASH). Multiplanar image reconstructions were done perpendicular to the acetabulum in the oblique-coronal, oblique-axial, and radial planes. The labral specimens were examined macroscopically. Results: In 12/20 hips (60%), a labral lesion was found on pathologic examination. In 7 specimens, the labrum was partially or completely detached in the weight-bearing superior region. One flap-like variant of the labrum was seen; in 4 hip joints, the labrum was degenerated (one cystic degeneration). Pathologic findings were confirmed by MRa in 8/12 specimens (sensitivity 67%). All degenerated labra were correctly diagnosed on MRa. Three small labral detachments and the flap-like variant were misinterpreted as being normal. There were no false positive findings (specificity 100%). The accuracy was 80%. Labral lesions were seen in 6/8 and in 6/12 of hips with and without osteoarthritis, respectively. Conclusion: MRa is well suited to delineate the acetabular labrum and to diagnose labral abnormalities. Detection of small labral detachments and anatomic variants is difficult and requires some experience. Labral lesions are correlated to osteoarthritis of the hip, but may be frequently seen in the elderly without underlying osteoarthritis. (orig.) [German] Ziel: Feststellung der Haeufigkeit von Laesionen des Labrum acetabulare bei aelteren Hueftgelenkspraeparaten und Untersuchung der Sensitivitaet und Spezifitaet der MR-Arthrographie (MRa) fuer die Darstellung dieser

  1. Acetabular fractures following rugby tackles: a case series

    Directory of Open Access Journals (Sweden)

    Morris Seamus

    2011-10-01

    Full Text Available Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting 'the tackle' to only two players may well reduce the likelihood of this life-altering injury.

  2. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    Energy Technology Data Exchange (ETDEWEB)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong (Second Hospital Affiliated to the Medical College of Xi' an Jiaotong Univ., Xi' an Shaanxi (China))

    2009-08-15

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8+-2.1 mm and 7.1+-3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  3. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    International Nuclear Information System (INIS)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong

    2009-01-01

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8±2.1 mm and 7.1±3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  4. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion

  5. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  6. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  7. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    Science.gov (United States)

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Para-acetabular peritendinitis calcarea; its radiographic manifestations

    International Nuclear Information System (INIS)

    Kawashima, Akira; Murayama, Sadayuki; Ohuchida, Toshiyuki; Russell, W.J.

    1987-02-01

    Peritendinitis calcarea and os acetabuli have long been confused during interpretations of hip-joint radiographs. Such confusion is reflected in the medical literature. The present study differentiated these two entities according to their interval radiographic progression and regression. There were 137 instances of para-acetabular calcifications among 110 subjects (59 men and 51 women), whose mean age was 46.8 years at the time of their initial detection. Twenty-six of the subjects had lumbago, which was probably unrelated. Other abnormalities including narrowed intervertebral spaces, scoliosis, and spondylolysis were observed in 21 of the subjects. These could have been responsible for any symptoms they had had, but none of the subjects complained of local hip-joint pain when the radiographs in question were made. Ninety-three of these instances of calcification were reviewed by means of serial radiographs. Interval changes in the sizes and shapes of the calcifications occurred among 90 of them, indicative of the latent type of peritendinitis calcarea. No interval changes were noted in the remaining three cases, indicating they were secondary ossification centers; namely, os acetabuli. This study showed that in asymptomatic adults, most para-acetabular calcifications were really not os acetabuli, but actually peritendinitis calcarea. (author)

  9. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  10. The preliminary application of magnetic resonance arthrography in the diagnosis of acetabular labrale tears

    International Nuclear Information System (INIS)

    Hong Wen; Zhang Xuezhe; Wang Wu; Yue Debo; Wang Weiguo

    2010-01-01

    Objective: To investigate the application value of MR arthrography (MRA) in the diagnosis of acetabular lab ral tears. Methods: Fifteen patients with a high degree of suspected acetabular lab ral tears received fluoroscope-guided injection of the contrast media into the hip joint (hip arthrography) and fat-saturated spin-echo T 1 -weighted images were obtained in the coronal, sagittal, oblique-axial and radial planes. Hip arthroscopy was performed on 12 of them. Results: Lab ral tears which were diagnosed in 11 patients by hip MRA were confirmed at hip arthroscopy. One patient showed no MRA indication of lab ral tear, also showed normal on arthroscopy. Tear in the anterior-superior quadrant 10 cases of 12 joints (12/13), posterior-superior quadrant 1 case of a joint (1/13). In 11 patients who underwent arthroscopy, hip MRA diagnosed 3 (3/13) joints labrale tears in coronal planes, 10 (10/13) joints in sagittal planes and 13 (13/13) labrale tears in axial-oblique and radial planes. In 15 patients with 20 hip joints, 5 cases 6 joints (6/20) with normal acetabular sublabral sulcus were performed. Conclusions: MR arthrography of hip is a reliable method in the diagnosis of acetabular labrale tears. Scanning method should be included fat-saturated spin-echo T 1 -weighted images in sagittal and oblique-axial planes or sagittal plus radial planes. The diagnosis of torn posterior-inferior quadrant should pay attention to the existence of a normal variation. (authors)

  11. early experience of operative treatment of pelvic and acetabular

    African Journals Online (AJOL)

    Objective: To review early post-operative results of pelvic and acetabular fracture intern al fixation. Design: ... 600 needing operative treatment annually. ... Infection was controlled with debridement and antibiotics. All the patients in the study returned to their work except one who has yet to do so 5 months after his injury.

  12. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    Science.gov (United States)

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  13. Visual reinforcement in the female Siamese fighting fish, Betta splendens.

    Science.gov (United States)

    Elcoro, Mirari; Silva, Stephanie P; Lattal, Kennon A

    2008-07-01

    Operant conditioning with Betta splendens (Bettas) has been investigated extensively using males of the species. Ethological studies of female Bettas have revealed aggressive interactions that qualitatively parallel those between male Bettas. Given these similarities, four experiments were conducted with female Bettas to examine the generality of a widely reported finding with males: mirror-image reinforcement. Swimming through a ring was reinforced by a 10-s mirror presentation. As with males, ring swimming was acquired and maintained when mirror presentations were immediate (Experiments 1, 2, and 3) and delayed (Experiment 4). The failure of conventional extinction (Experiments 1 and 2) and response-independent mirror presentations (Experiment 3) to maintain responding confirmed the reinforcing properties of mirror presentation. These results extend previous findings of mirror images as reinforcers in males of the same species and illustrate a complementarity between behavioral ecology and the experimental analysis of behavior.

  14. Clinical and Radiological Results over the Medium Term of Isolated Acetabular Revision

    Directory of Open Access Journals (Sweden)

    Nicola Piolanti

    2014-01-01

    Full Text Available Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60 of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32. 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1% showed thigh pain and only 4 hips (12.11% presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.

  15. Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study.

    Directory of Open Access Journals (Sweden)

    Zhenfei Huang

    Full Text Available Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D details and tactile feedback of real fractures. Virtual reality (VR and 3D printing (3DP techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM, VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.

  16. Early Versus Late Weight-Bearing Protocols for Surgically Managed Posterior Wall Acetabular Fractures.

    Science.gov (United States)

    Heare, Austin; Kramer, Nicholas; Salib, Christopher; Mauffrey, Cyril

    2017-07-01

    Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematically reviewed the current literature to determine if a difference in outcome exists between early and late postoperative weight-bearing protocols for surgically managed posterior wall acetabular fractures. PubMed and MEDLINE were searched for posterior wall acetabular fracture studies that included weight-bearing protocols and Merle d'Aubigné functional scores. Twelve studies were identified. Each study was classified as either early or late weight bearing. Early weight bearing was defined as full, unrestricted weight bearing at or before 12 weeks postoperatively. Late weight bearing was defined as restricted weight bearing for greater than 12 weeks postoperatively. The 2 categories were then compared by functional score using a 2-tailed t test and by complication rate using chi-square analysis. Six studies (152 fractures) were placed in the early weight-bearing category. Six studies (302 fractures) were placed in the late weight-bearing category. No significant difference in Merle d'Aubigné functional scores was found between the 2 groups. No difference was found regarding heterotopic ossification, avascular necrosis, superficial infections, total infections, or osteoarthritis. This systematic review found no difference in functional outcome scores or complication rates between early and late weight-bearing protocols for surgically treated posterior wall fractures. [Orthopedics. 2017: 40(4):e652-e657.]. Copyright 2017, SLACK Incorporated.

  17. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  18. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    Energy Technology Data Exchange (ETDEWEB)

    Chun, K.A. [The Catholic University of Korea Uijongbu St. Mary' s Hospital, Department of Radiology, Uijongbu, Kyunggi-Do 480-130 (Korea); University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States); Morcuende, J. [University of Iowa Hospitals and Clinics, Department of Orthopaedic Surgery, Iowa City (United States); El-Khoury, G.Y. [University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States)

    2004-12-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  19. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    International Nuclear Information System (INIS)

    Chun, K.A.; Morcuende, J.; El-Khoury, G.Y.

    2004-01-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  20. [Posterior partial trochanteric osteotomy for the treatment of the roof involved acetabular fractures].

    Science.gov (United States)

    Wang, Pan-Feng; Xu, Shuo-Gui; Zhang, Chun-Cai; Fu, Qing-Ge; Zhang, Yun-Tong; Liu, Xin-Wei; Niu, Yun-Fei; Tang, Yang

    2013-11-01

    To introduce a new trochanteric osteotomy,and evaluate the outcome of the procedure combined a posterior lateral approach in treating acetabular fractures which involving the roof. Between March 2007 and Novmber 2010,30 patients with displaced acetabular fractures involving the dome need trochanteric osteotomy were retrospectively reviewed. There were 21 males and 9 females,ranging in age from 18 to 70 years with an average of 35.2 years at the time of injury. According to Letournel-Judet classification, there were 10 posterior wall fractures,7 posterior column fractures,5 transverse fractures, 2 T-shape fractures, 1 transverse associated with posterior wall fracture, 3 posterior column and wall fractures and 2 bicolumn fractures. The standards of Matta,the modified Merle d'Aubigne-Postel, Medical Research Council were respectively used to evaluate the reduction result, function of hip joint and the strength of hip abduction. All patients were followed up with an average time of 25 months (18 to 40) and all osteotomy sites obtained bone union with an average time of 8.4 weeks (6 to 12). No bone non-union, bone block displaceing, internal fixation looseing and breaking,infection of deep part were found. Seventeen patients got anatomic reduction, 12 got satisfied reduction, and 1 got unsatisfied result according to the criteria of Matta. At final follow-up, function of hip joint obtained excellent results in 11 cases, good in 15, fair in 3 and poor in 1. The strength of the abductors of 3 patients were grade 4 and 27 patients were grade 5. Posterior partial great trochanteric osteotomy can enhance the exposure and provide a more accurate reduction and degrade the difficulty of acetabular fracture fixation without increasing the risk of complications. The method provide a new way for the treatment of the roof involved acetabular fractures.

  1. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures

    Directory of Open Access Journals (Sweden)

    Sandeep Gupta

    2017-06-01

    Conclusion: Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way.

  2. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  3. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  4. Cam deformity and acetabular dysplasia as risk factors for hip osteoarthritis

    NARCIS (Netherlands)

    Hosnijeh, Fatemeh Saberi; Zuiderwijk, Maria E; Versteeg, Mathijs; Smeele, Hieronymus T W; Hofman, Albert; Uitterlinden, André G; Agricola, Rintje; Oei, Edwin H G; Waarsing, Jan H; Bierma-Zeinstra, Sita M; van Meurs, Joyce B J

    2017-01-01

    Objective: Cam deformity and acetabular dysplasia have been recognized as relevant risk factors for hip osteoarthritis (OA) in a few prospective studies with limited sample sizes. To date, however, no evidence is available from prospective studies regarding whether the magnitude of these

  5. Femoro-acetabular impingement and hip pain with conventionally normal x-rays.

    LENUS (Irish Health Repository)

    Baker, J F

    2010-06-01

    There has in recent years been a fundamental change in the understanding of hip pain in the young adult and hip pain without plain radiographic findings of arthritis. Pain in these groups has long represented a diagnostic and therapeutic challenge. With new appreciation of hip biomechanics, pathological processes and the arrival of modern imaging modalities we now have a greater understanding of non-arthritic hip pathology. One of the commonest yet least well recognized \\'new\\' diagnoses around the hip is femoro-acetabular impingement (FAI). FAI is a developmental condition of the hip joint that is associated with abnormal anatomical configuration and thus joint mechanics on either the femoral or acetabular sides or both. It is hypothesized to have a variety of precipitants and may ultimately lead to labral and chondral injury and what has previously been referred to as \\'primary\\' or \\'idiopathic\\' hip osteoarthritis.

  6. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    Science.gov (United States)

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  7. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  8. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  9. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    Science.gov (United States)

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  10. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    Science.gov (United States)

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case

  11. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Absence or interruption of the supra-acetabular line: a subtle plain film indicator of hip pathology

    International Nuclear Information System (INIS)

    Major, N.M.; Helms, C.A.

    1996-01-01

    Objective. To show that absence or interruption of the supraacetabular line is a subtle plain film indicator of pathology in the acetabulum. Design. Nineteen hips from 17 patients with known disease processes involving the acetabulum as demonstrated by subsequent magnetic resonance imaging, bone scan or plain film follow-up were evaluated with antero-posterior (AP) plain films of the pelvis. Three additional cases were diagnosed prospectively using interruption of the supra-acetabular line as the criterion for inclusion. Fifty AP plain films of the pelvis in patients without hip pain were examined prospectively to determine normal imaging criteria. Results and conclusions. The normal supra-acetabular line measures 2-3 mm in thickness superiorly and is a thin sclerotic line in the medial aspect. In all 22 hips (with pathology) in this series, the line was interrupted or absent. Loss or interruption of the supra-acetabular line may thus be a subtle pain film indicator of a disease process involving the acetabulum. This plain film sign has not previously been reported. (orig.). With 8 figs., 1 tab

  13. Acetabular osteotomy for double boarding in lateral decubitus. Anatomical bases and surgical technique

    International Nuclear Information System (INIS)

    Lazennec, J Y; Del Vecchio, R; Saillant, G

    2001-01-01

    The periacetabular osteotomies of reorientation of the eotilo have a reputation of being difficult from the technical point of view. The authors present a technique of juxta acetabular osteotomy that respects the posterior column of the acetabulo the same as the GANZ technique. The osteotomy is of simpler realization thanks to an installation that allows carrying out two simultaneous boarding. The osteotomy lines, their rectilinear and controllable in permanency through of images intensificator and they don't constitute any risk for the essential vascular contribution of the obturatriz artery and their branches. Their other interest comes represented by the possibility of correcting easily the parasitic retroversion associated to the descent of the whole eotilo, that it allows to avoid the bad positions that they affect the center of the articulation and the widths acetabular

  14. Should total hip arthroplasty be performed acutely in the treatment of acetabular fractures in elderly or used as a salvage procedure only?

    Directory of Open Access Journals (Sweden)

    Katharine Hamlin

    2017-01-01

    Full Text Available Background: Total hip arthroplasty (THA is now an increasingly common procedure for people sustaining acetabular fractures. The incidence of acetabular fractures among the elderly population is increasing, and contemporary treatment aims to avoid the risks of prolonged incumbency associated with poor bone stock for fixation or inability to comply with limited weightbearing in this patient group. The concept of acute hip arthroplasty as a treatment for acetabular fracture is, therefore, becoming more topical and relevant. Our systematic review investigates whether THAs for acetabular fractures should be performed acutely, with a short delay, or as a late procedure for posttraumatic osteoarthritis (PTOA if it develops. Materials and Methods: Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines were followed when undertaking this systematic review. Detailed searches were performed on three different databases, using keywords, such as “acetabular fracture,” “acetabular trauma,” “total hip arthroplasty,” “hip arthroplasty,” and “hip prosthesis.” Studies from 1975 to September 2016 were included in the study. All studies included in the review were independently critically appraised by two of the authors. Results: Forty three studies were included in this review. Only two of them actually compared acute and delayed THAs for acetabular fractures with the rest focusing on one or the other. Results were comparable between acute and late THAs in terms of aseptic loosening, operative time, blood loss, Harris Hip Score, and ability to mobilize postoperatively without aid. Complication rates, however, were much higher in the acute group. Conclusion: Evidence based on this topic is scarce and therefore we have to be cautious about drawing a definitive conclusion. The findings of this systematic review do suggest, however, that acute THAs should be considered in elderly patients, where fixation is not possible, or

  15. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    Science.gov (United States)

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Revisión acetabular con conservación del componente metálico osteointegrado y cementado de un componente de poliestireno. Reporte de una serie de 40 casos. [Acetabular revision cementing a liner into a stable acetabular shell

    Directory of Open Access Journals (Sweden)

    Fernando Manuel Bidolegui

    2013-12-01

    Full Text Available In­tro­duc­ción: Un escenario cada vez más frecuente en la cirugía de revisión protésica de la cadera es hallar un cotilo no cementado fijo con una falla del componente modular de polietileno. Una completa revisión acetabular se presenta como demasiado agresiva cuando el componente metálico es salvable. Cementar un nuevo inserto de polietileno dentro del componente acetabular metálico os-teointegrado es una alternativa. Comunicamos los resultados con esta técnica, y sus indicaciones, el modo de realización y las posibles limitaciones. Materiales­y­Métodos: Entre 2001 y 2011, se cementaron 40 componentes de polietileno dentro de copas no cementadas. Se evaluó radiológicamente y clínicamente a todos los pacientes. El motivo por el que se cementó un inserto fue falla o rotura de mecanismo de captura (11 casos; 27,5%, ganar estabilidad (18 casos; 45% y falta de disponibilidad del inserto correspondiente (11 casos, 27,5%. Resultados:­ La tasa de duración del implante sin reoperación a 46 meses de seguimiento fue del 92%. Un paciente (2,4% sufrió una infección, y dos presentaron inestabilidad (4,8%. No se presentaron aflojamientos hasta el último seguimiento. El puntaje preoperatorio y posoperatorio en la escala de Harris fue de 59 y 80, respectivamente. Conclusiones: Los datos técnicos por considerar para tener éxito son: utilizar un inserto de menor tamaño que el de la copa, cementar insertos texturizados y dejar siempre como mínimo un manto de cemento uniforme de 2 mm. Nuestros resultados preliminares cementando un inserto de polietileno dentro de una copa acetabular osteointegrada parecerían justificar esta técnica de revisión en pos de prevenir la pérdida de capital óseo asociada a la necesidad de recambio de copas osteointegradas.

  17. Copas de metal trabecular y aloinjertos óseos impactados en defectos acetabulares graves. Resultados a los 2-4 años. [Impacted bone allografts and trabecular metal cups in severe acetabular bone defects: 2 to 4-year results.

    Directory of Open Access Journals (Sweden)

    Martín Buttaro

    2014-06-01

    Full Text Available In­tro­duc­ción: El objetivo principal es presentar la supervivencia del componente acetabular en pacientes con defectos graves reconstruidos con copas de metal trabecular combinadas con aloinjertos óseos impactados. Como objetivo secundario, se compararon estos resultados con los previamente obtenidos por los autores en defectos de similar gravedad utilizando anillos de reconstrucción y aloinjertos óseos. Materiales­ y­ Métodos:­ Se realizaron 20 cirugías de revisión en 19 pacientes (edad promedio 65 años, controlados, de forma prospectiva, con defectos acetabulares graves tipos 3A o 3B de Paprosky, por falla mecánica o infecciosa. El puntaje funcional promedio preoperatorio fue de 6,2 puntos, según la escala de Merle D ́Aubigne. Siempre se utilizaron copas de metal trabecular y aloinjertos óseos impactados. Resultados:­ A los 30 meses de seguimiento promedio (rango 24-48 meses, la supervivencia del componente acetabular fue del 95% (IC = 75%-98%. Un paciente presentó un aflojamiento acetabular por infección profunda a las 16 semanas de la revisión y fue tratado con una artroplastia de resección. El puntaje funcional promedio, excluido el caso con aflojamiento posoperatorio, fue de 16,2 puntos. Se observó la incorporación de los aloinjertos óseos en todos los pacientes, salvo el caso con infección profunda. La comparación con nuestras series históricas reconstruidas con anillos de Kerboull o con anillos GAP arrojó resultados altamente favorables a favor de las copas de metal trabecular.  Conclusiones: Las copas de metal trabecular asociadas a aloinjertos óseos impactados ofrecen una alternativa válida en cirugía de revisión acetabular con defectos graves del capital óseo. Este método se asocia a resultados más favorables que los obtenidos antes con anillos de reconstrucción.

  18. Human bone ingrowth into a porous tantalum acetabular cup

    Directory of Open Access Journals (Sweden)

    Gregory N. Haidemenopoulos

    2017-11-01

    Full Text Available Porous Tantalum is increasingly used as a structural scaffold in orthopaedic applications. Information on the mechanisms of human bone ingrowth into trabecular metal implants is rather limited. In this work we have studied, qualitatively, human bone ingrowth into a retrieved porous tantalum monoblock acetabular cup using optical microscopy, scanning electron microscopy and energy dispersive X-ray analysis. According to the results and taking into account the short operational life (4 years of the implant, bone ingrowth on the acetabular cup took place in the first two-rows of porous tantalum cells to an estimated depth of 1.5 to 2 mm. The bone material, grown inside the first raw of cells, had almost identical composition with the attached bone on the cup surface, as verified by the same Ca:P ratio. Bone ingrowth has been a gradual process starting with Ca deposition on the tantalum struts, followed by bone formation into the tantalum cells, with gradual densification of the bone tissue into hydroxyapatite. A critical step in this process has been the attachment of bone material to the tantalum struts following the topology of the porous tantalum scaffold. These results provide insight to the human bone ingrowth process into porous tantalum implants.

  19. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty

    International Nuclear Information System (INIS)

    White, S.P.; Blom, A.W.; Lee, M.; Smith, E.J.

    2005-01-01

    To study whether there was a common pattern of clinical symptoms, signs and radiographic features for the dissociation of the polyethylene liner from an acetabular component and to postulate reasons for these features. Retrospective study of notes and radiographs of cases of revision hip arthroplasty for polyethylene liner dissociation of the cementless Harris-Galante I porous-coated acetabular component (Zimmer Inc, Warsaw, IN) at the Avon Orthopaedic Centre, Bristol, UK and St. Mary's Hospital, Bristol, UK between 1995 and 2004. Patients were contacted to confirm preoperative symptoms. Nine cases of late polyethylene liner dissociation of this prosthesis have been revised in these institutions. All patients presented with a reduction in mobility, groin pain and limp. Eight patients reported an audible noise on hip movement. In all cases, radiographs showed radiolucency medial to the femoral neck in association with an eccentrically placed femoral head showing contact with the acetabular metal shell, which we have termed the ''crescent sign.'' There is a typical clinical presentation in this study. The diagnosis can be made from a single anteroposterior pelvic radiograph without the need for previous films for comparison, or the need for arthrography. Clinicians should look specifically for the crescent sign when an eccentrically placed femoral head has been noted, in order to differentiate the more unusual diagnosis of dissociation from that of polyethylene wear. Early revision surgery can prevent damage to the femoral head and metal acetabular shell, thus reducing the complexity of revision surgery. (orig.)

  20. Difficult acetabular revision. A preliminary report.

    Science.gov (United States)

    Newport, M L; Stuchin, S A; Frankel, V H; Zuckerman, J

    1986-01-01

    Thirteen patients (14 hips) underwent revision from conventional cemented total hip arthroplasty to uncemented acetabular threaded screw-in components and cementless femoral press-fit stems by means of the Autophor, Biofit, and Ti-Thread designs. The patients suffered from all forms of primary hip disease except rheumatoid arthritis; their average age was 34 years. The average preoperative Harris hip score was 39.4; the average postoperative score was 71.2 at six months, 90.6 at one year, and 91.6 at two years. Complications included two femoral shaft fractures, one femoral nerve palsy, and one dislocation. No signs have been observed of loosening or migration as of an early (6-24 months) follow-up.

  1. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    Science.gov (United States)

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  2. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  3. Acetabular QCT in Total Hip Arthroplasty - a reliability study using porcine hips

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    and reliability of bone mineral density measurements (BMD) in close proximity of the acetabular cup using SECT and DECT images and 3D segmentation software. Materials and methods 22 acetabular cups (12 cemented, 10 un-cemented) were inserted in porcine hip specimens ex vivo. A femoral stem was attached to each...... difference between the double measurements in SECT was 8 mg/cm3 (p=0.64) and 2 mg/cm3 in DECT (p=0.6). In the cemented concept the differences were 33 mg/cm3 (p=0.054) and 11 mg/cm3 (p=0.014), respectively. ICC was >0.90 regardless of scan mode and cup type. In both cup types the Bland-Altman limits...... of agreement were wider in SECT (uncemented: -95 to 111; cemented: -86 to 153) compared with DECT (uncemented: -28 to 23; cemented: -21 to 44). Conclusion There were no statistically significant reliability differences between SECT and DECT, but results suggest that the agreement of DECT is better than...

  4. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup

    Directory of Open Access Journals (Sweden)

    Guillermo Urriolagoitia-Calderón

    2008-01-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.

  5. T2* Mapping Provides Information That Is Statistically Comparable to an Arthroscopic Evaluation of Acetabular Cartilage.

    Science.gov (United States)

    Morgan, Patrick; Nissi, Mikko J; Hughes, John; Mortazavi, Shabnam; Ellerman, Jutta

    2017-07-01

    Objectives The purpose of this study was to validate T2* mapping as an objective, noninvasive method for the prediction of acetabular cartilage damage. Methods This is the second step in the validation of T2*. In a previous study, we established a quantitative predictive model for identifying and grading acetabular cartilage damage. In this study, the model was applied to a second cohort of 27 consecutive hips to validate the model. A clinical 3.0-T imaging protocol with T2* mapping was used. Acetabular regions of interest (ROI) were identified on magnetic resonance and graded using the previously established model. Each ROI was then graded in a blinded fashion by arthroscopy. Accurate surgical location of ROIs was facilitated with a 2-dimensional map projection of the acetabulum. A total of 459 ROIs were studied. Results When T2* mapping and arthroscopic assessment were compared, 82% of ROIs were within 1 Beck group (of a total 6 possible) and 32% of ROIs were classified identically. Disease prediction based on receiver operating characteristic curve analysis demonstrated a sensitivity of 0.713 and a specificity of 0.804. Model stability evaluation required no significant changes to the predictive model produced in the initial study. Conclusions These results validate that T2* mapping provides statistically comparable information regarding acetabular cartilage when compared to arthroscopy. In contrast to arthroscopy, T2* mapping is quantitative, noninvasive, and can be used in follow-up. Unlike research quantitative magnetic resonance protocols, T2* takes little time and does not require a contrast agent. This may facilitate its use in the clinical sphere.

  6. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    Science.gov (United States)

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  7. Use of iPhone technology in improving acetabular component position in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Xiau Wei Tay, MBBS

    2017-09-01

    Full Text Available Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1 free hand, (2 alignment jig (Sputnik, and (3 iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section. Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant (F[2,51] = 4.17, P = .02 in the “untrained group”. There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.

  8. Lumbosacral plexopathies associated with acetabular fracture

    Directory of Open Access Journals (Sweden)

    Patpiya Sirasaporn

    2017-01-01

    Full Text Available Lumbosacral plexopathies are of considerably less epidemiologic common prevalence than brachial plexus. The most common form of trauma resulting in lesions affecting the lumbosacral plexus is injuries to sacroiliac region. The symptoms which are caused by compressing lumbosacral plexus are sensory disturbance and weakness in an affected leg. The author reports a case of a 65-year-old male with a history of right acetabular fracture status post open reduction and internal fixation by plate and screw who complained weakness and numbness in the right leg. Four months later, he still had difficulty in walking and felt paresthesia at the right lateral thigh and entire of the right foot. His further investigation which was electrodiagnostic study was diagnosed as right lumbosacral plexopathies.

  9. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    Science.gov (United States)

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    Science.gov (United States)

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Acetabular labral tears with underlying chondromalacia: a possible association with high-level running.

    Science.gov (United States)

    Guanche, Carlos A; Sikka, Robby S

    2005-05-01

    The use of hip arthroscopy has helped delineate intra-articular pathology and has enabled clinicians to further elucidate the factors responsible for injuries, such as running. The subtle development of degenerative changes may be a result of repetitive impact loading associated with this sport. This study presents a population of runners with common pathologic acetabular changes. Case series. Eight high-level runners with an average age of 36 years (range, 19 to 45 years) were seen for complaints of increasing hip pain with running without any history of macrotrauma. All of the patients had either run several marathons (4), were triathletes (1), Olympic middle distance runners (1), or had run more than 10 miles per week for longer than 5 years (2). Plain radiographic analysis revealed no degenerative changes and an average center-edge (CE) angle of 36.7 degrees (range, 28 degrees to 44 degrees). All patients underwent hip arthroscopy with labral debridement. In 6 patients (75%), a chondral injury of the acetabular cartilage underlying the labral tear was noted. In addition, 3 patients had ligamentum teres disruptions. It is possible that the development of these tears is the result of subtle instability, which may be exacerbated by running, eventually leading to labral tearing and possible ligamentum teres disruption. While perhaps concurrently, subtle acetabular dysplasia may play a role. Although this study does not confirm an association between running and the development of labral tears or chondral lesions in the hip, it certainly questions whether there is an injury pattern common to this population, a "runner's hip." Level IV.

  12. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  13. Lubrication of ceramics in ring/cylinder applications

    International Nuclear Information System (INIS)

    Gaydos, P.A.; Dufrane, K.F.

    1989-01-01

    In support of efforts to apply ceramics to advanced heat engines, a study was performed of the wear mechanisms of ceramics at the ring/cylinder interface. A laboratory apparatus was constructed to reproduce most of the conditions of an actual engine but used easily prepared ring and cylinder specimens to facilitate their fabrication. Plasma-sprayed coatings of Cr 2 O 3 and hypersonic flame-sprayed coatings of cobalt-bonded WC performed particularly well as ring coatings. Similar performance was obtained with these coatings operating against SiC, Si 3 N 4 , SiC whisker-reinforced Al 2 O 3 and Cr 2 O 2 coatings. The study demonstrated the critical need for lubrication and evaluated the performance of two available lubricants

  14. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  15. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures.

    Science.gov (United States)

    Gupta, Sandeep; Singh, Jagdeep; Virk, Jagandeep Singh

    2017-06-01

    Complete visualization of certain acetabular fractures of posterior wall or column with cranial extension involving superior dome from standard surgical exposures is a challenge. Osteotomy of the greater trochanter has been used to enhance fracture visualization, especially the dome, in posterior and lateral exposures of the acetabulum. It also decreases the need for excessive muscle retraction. The purpose of the study was to investigate the outcome associated with trochanteric flip osteotomy in the management of certain acetabulum fractures. From January 2011 to December 2013, 25 displaced acetabular fractures were treated by open reduction and internal fixation. The fractures were managed using a Kocher-Langenbeck approach along with trochanteric flip osteotomy. At 3rd, 6th and 24th month follow-up, all patients had radiographic examination and underwent a final clinical evaluation based on the modified Merle d'Aubigne and Postel score. The strength of the abductors was assessed according to the Medical Research Council (MRC) grading system. Congruent reduction was achieved in all patients and all osteotomies healed within an average period of 3.8 months. All our patients were allowed full weight bearing at the end of 3 months and with no abductor lurch at the end of 6 months follow-up. There were no cases of avascular necrosis of femoral head. None of the patients had any neurovascular complication or infection by the end of the follow-up period. Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  16. The development and nature of femoral head cam lesions following acetabular fractures.

    Science.gov (United States)

    Berber, Onur; Foote, Julian; Sabharwal, Sanjeeve; Datta, Gorav; Bircher, Martin D

    2014-01-01

    The aim of acetabular fracture fixation is to restore joint congruity with restoration of the articular surface. Poor outcomes are seen where this has not been achieved. Letournel reported a collarette osteophyte seen postoperatively in a proportion of patients, which he suggested was an early precursor to the development of osteoarthritis. This is a retrospective study of patients treated at a tertiary referral unit who developed this lesion. The triangular index was measured in 48 of these patients and then correlated with their clinical findings, Oxford Hip Score and the presence of osteoarthritis. Length of follow-up, fracture classification, and joint congruency were also recorded. Results showed a statistically significant relationship between cam lesion size and the development of osteoarthritis (P = 0.008), cam lesion size and length of follow-up (P = 0.01), and between groin pain and postoperative joint congruency (LR = 0.035). These findings suggest that the appearance of a cam lesion is a poor long-term prognostic marker for the development of osteoarthritis in patients with an acetabular fracture.

  17. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  18. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  19. Abordagem cirúrgica inédita para denervação acetabular em cães A new surgical approach to acetabular denervation in dogs

    Directory of Open Access Journals (Sweden)

    Cássio R.A. Ferrigno

    2007-02-01

    Full Text Available Este artigo tem por objetivo demonstrar nova abordagem cirúrgica para denervação seletiva das fibras sensitivas do periósteo acetabular, para tratamento da displasia coxo femoral em cães, conduzidas em 189 articulações. Para tanto, é descrita abordagem da região cranial e dorso-lateral do acetábulo de cães por incisão em forma de meia lua de aproximadamente de três centímetros de extensão, iniciando trocânter maior do fêmur e em direção ao corpo do ílio. Após rebatimento dorsal do músculo glúteo médio, secciona-se parcialmente a inserção do m. glúteo profundo para acesso às regiões citadas. Com auxílio de cureta foi removido, em todos os pacientes, periósteo na margem acetabular cranial e dorso lateral, até a exposição da cortical óssea. Em todos os animais foi possível a abordagem, tanto da face cranial como também acesso para a curetagem da face dorsal do acetábulo, com a técnica descrita, com incisão de pele de aproximadamente 3,2cm. A curetagem da porção cranial do acetábulo foi, em todos os casos realizados, sem visualização do osso, mas de fácil confecção e sem intercorrências de lesão de nervos ou músculos. Em todas as abordagens foi possível visualizar a cápsula articular da articulação coxo femoral, e em nenhum dos animais esta estrutura foi incisada por erro de técnica. Conclui-se que a abordagem cirúrgica descrita no presente trabalho é factível para este tipo de procedimento cirúrgico em cães, promovendo acesso adequado, com mínima invasão e sem complicações de qualquer natureza.The purpose of this study is to demonstrate a new surgical approach for the selective denervation of the sensitive fibers of the acetabular periosteum, for the treatment of hip dysplasia in dogs, conducted in 189 joints.The surgical approach of the cranial and dorso-lateral regions of the acetabular joint in dogs, by moon-shaped incision of approximately 3cm in extension, starting from the

  20. Single-stage Acetabular Revision During Two-stage THA Revision for Infection is Effective in Selected Patients.

    Science.gov (United States)

    Fink, Bernd; Schlumberger, Michael; Oremek, Damian

    2017-08-01

    The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All

  1. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study.

    Science.gov (United States)

    Gurgel, Henrique M C; Croci, Alberto T; Cabrita, Henrique A B A; Vicente, José Ricardo N; Leonhardt, Marcos C; Rodrigues, João Carlos

    2014-01-01

    In a study of the acetabular component in total hip arthroplasty, 20 hips were operated on using imageless navigation and 20 hips were operated on using the conventional method. The correct position of the acetabular component was evaluated with computed tomography, measuring the operative anteversion and the operative inclination and determining the cases inside Lewinnek's safe zone. The results were similar in all the analyses: a mean anteversion of 17.4° in the navigated group and 14.5° in the control group (P=.215); a mean inclination of 41.7° and 42.2° (P=.633); a mean deviation from the desired anteversion (15°) of 5.5° and 6.6° (P=.429); a mean deviation from the desired inclination of 3° and 3.2° (P=.783); and location inside the safe zone of 90% and 80% (P=.661). The acetabular component position's tomography analyses were similar whether using the imageless navigation or performing it conventionally. Published by Elsevier Inc.

  2. Clinical outcome of pedestal cup endoprosthetic reconstruction after resection of a peri-acetabular tumour

    NARCIS (Netherlands)

    Bus, M. P. A.; Boerhout, E. J.; Bramer, J. A. M.; Dijkstra, P. D. S.

    2014-01-01

    Peri-acetabular tumour resections and their subsequent reconstruction are among the most challenging procedures in orthopaedic oncology. Despite the fact that a number of different pelvic endoprostheses have been introduced, rates of complication remain high and long-term results are mostly lacking.

  3. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  4. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  5. Computer-aided designed, three dimensional-printed hemipelvic prosthesis for peri-acetabular malignant bone tumour.

    Science.gov (United States)

    Wang, Baichuan; Hao, Yongqiang; Pu, Feifei; Jiang, Wenbo; Shao, Zengwu

    2018-03-01

    Prosthetic reconstruction may be a promising treatment for peri-acetabular malignant bone tumour; however, it is associated with a high complication rate. Therefore, prosthetic design and approach of prosthetic reconstruction after tumour resection warrant study. We retrospectively analyzed 11 patients with peri-acetabular malignant bone tumours treated by personalized 3D-printed hemipelvic prostheses after en bloc resection between 2015 and 2016. Pre-operative and post-operative pain at rest was assessed according to a 10-cm VAS score. The results of functional improvement were evaluated using the MSTS-93 score at the final follow-up. We also analyzed tumour recurrence, metastases, and complications associated with the reconstruction procedure. All patients were observed for six to 24 months with an average follow-up of 15.5 months. One patient had occasional pain of the involved hip at the final follow-up (VAS, pre vs. post 8 months: 3 vs. 2). The mean MSTS-93 score was 19.2 (range, 13-25). Hip dislocation was detected in two patients, while delayed wound healing occurred in one patient. One patient with mesenchymal chondrosarcoma had a left iliac bone metastasis. Local tumour recurrence was not observed. Reconstruction of bony defect after tumour resection using personalized 3D-printed hemipelvic prostheses can obtain acceptable functional results without severe complications. Based on previous reports and our results, we believe that reconstruction arthroplasty using 3D-printed hemipelvic prostheses will provide a promising alternative for those patients with peri-acetabular malignant bone tumours. Level IV, therapeutic study.

  6. Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis.

    Science.gov (United States)

    Wang, Xuyi; Peng, Jianping; Li, De; Zhang, Linlin; Wang, Hui; Jiang, Leisheng; Chen, Xiaodong

    2016-10-04

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the "normal" range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the "normal" range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the "normal" range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological "normal" range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the "normal" range, within the "normal" range, and less than the lower limit of the "normal" range, respectively.

  7. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    2017-01-01

    in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT).PurposeTo test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed...... with single-energy CT (SECT) and DECT in cemented and cementless cups.Material and Methods: Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed.......Results: BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found...

  8. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  9. Migration measurement of acetabular components in cementless total hip arthroplasty; Messung der Pfannenwanderung bei zementfreien Hueftimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, A.; Karbowski, A.; Schwitalle, M.; Vogel, J.; Boden, F.; Seeleitner, C. [Mainz Univ. (Germany). Orthopaedische Klinik und Poliklinik; Schunk, K. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Mayrhofer, P. [Innsbruck Univ. (Austria). Inst. fuer Mathematik und Geometrie

    1998-08-01

    Migration measurements of acetabular components using a special computer aided method (EBRA = abbrevation for the German term ``Ein-Bild-Roentgenanalyse``) were performed to evaluate early results of the implants and predict aseptic loosening. Methods: Standard ap-radiographs of the pelvis were marked, specific points were digitised. Simulating the spatial situation the programme computes lengitudinal and vertical migration of the cup. 74 acetabular components in 71 patients could be studied by migration measurements. Results: 14 patients showed migration of more than 1 mm, which is the confidence limit of this method. Each of these patients showed diverse reasons for the migration, i.e. osteoporosis of the acetabular bone stock or problems concerning the surgical technique which means malposition of the cup or insufficient reaming of the bone. There were some patients with severe congenital dysplasia of the hip and in some cases the inclination angle of the cup was too great. Conclusion: The technique applied for measuring migration of acetabular components can be useful for evaluating early instability of the implant and can be helpful in detecting problems concerning the surgical technique. (orig.) [Deutsch] Mittels der Ein-Bild-Roentgenanalyse wurden Pfannenwanderungen nach Implantation von zementfreien, sphaerischen Hueftgelenkspfannen erfasst, um Praediktoren fuer die langfristige Prognose der Implantate zu evaluieren. Methoden: Nach Markierung von Referenzpunkten in den Beckenuebersichtsaufnahmen wurden diese digitalisiert, vom Programm verrechnet und die Wanderung des Implantats im Verlauf angegeben. Bei 71 Patienten wurden von 74 Pfannen ueber einen Mindestnachuntersuchungszeitraum von 12 Monaten Migrationsmessungen durchgefuehrt. Das Konfidenzintervall der Methode liegt bei <1 mm. Bei jedem dieser Patienten fanden sich Hinweise entweder auf ein schlechtes Knochenlager, auf operationsbedingte Probleme, wenn keine ausreichende Primaerstabilitaet der Pfanne

  10. Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

    Directory of Open Access Journals (Sweden)

    Reza Firoozabadi

    2015-09-01

    Full Text Available Purpose: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnormalities to aid surgeons in detecting these abnormalities preoperatively and coordinating a surgical plan with a general surgeon.Methods: Clinical study- Retrospective review of treated acetabular fractures through an ilioinguinal approach. Incidence of inguinal canal and spermatic cord abnormalities requiring general surgery consultation were identified. Corresponding CT scans were reviewed and radiographic characteristics of the spermatic cord abnormalities and/or hernias were noted.Cadaveric study- 18 male cadavers dissected bilaterally using an ilioinguinal exposure. The inguinal canal and the contents of the spermatic cord were identified and characterized.Results: Clinical Study- 5.7% (5/87 of patients had spermatic cord lesion and/or inguinal hernia requiring general surgical intervention. Preoperative pelvic CT scan review identified abnormalities noted intraoperatively in four of the five patients. Cord lipomas visualized as enlargements of the spermatic cord with homogeneous density. Hernias visualized as enlarged spermatic cords with heterogeneous density. Cadaver Study- 31% (11/36 of cadavers studied had spermatic cord and/or inguinal canal abnormalities. Average cord diameter in those with abnormalities was 24.9 mm (15-28 compared to 16 mm (11-22 in normal cords, which was statistically significant.Conclusion: The clinical and cadaveric findings emphasize the importance of understanding inguinal abnormalities and the value of detecting them preoperatively. The preoperative pelvic CT scans were highly sensitive in detecting inguinal abnormalities.

  11. [Stress analysis on the acetabular side of bipolar hemiarthroplasty by the two-dimensional finite element method incorporating the boundary friction layer].

    Science.gov (United States)

    Ichihashi, K; Imura, S; Oomori, H; Gesso, H

    1994-11-01

    We compared the biomechanical characteristics of bipolar and unipolar hemiarthroplasty on the proximal migration of the outer head by determining the von Mises stress distribution and acetabular (outer head) displacement with clinical assessment of hemiarthroplasty in 75 patients. This analysis used the two-dimensional finite element method, which incorporated boundary friction layers on both the inner and outer bearings of the prosthesis. Acetabular reaming increased stress within the pelvic bone and migration of the outer head. A combination of the acetabular reaming and bone transplantation increased the stress within the pelvic bone and grafted bone, and caused outer head migration. These findings were supported by clinical results. Although the bipolar endoprosthesis was biomechanically superior to the unipolar endoprosthesis, migration of the outer head still occurred. The bipolar endoprosthesis appeared to be indicated in cases of a femoral neck fracture or of avascular necrosis in the femoral head, but its use in cases of osteoarthritis in the hip required caution.

  12. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study

    DEFF Research Database (Denmark)

    Baad-Hansen, Thomas; Kold, Søren; Kaptein, Bart L

    2007-01-01

    BACKGROUND: In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years...

  13. Surgical treatment of acetabular fractures: clinical and radiological results and its complications

    International Nuclear Information System (INIS)

    Martinez, C; Rey, R.

    2011-01-01

    The objective of this work is to analyse a serie of consecutive cases of surigically treated acetabular fractures, evaluating middle-term clinical and radiological results. A retrospective analysis of clinical histories, surgical forms and X-rays was performed for 42 patients who underwent surgery in two centers (Instituto Nacional de Ortopedia y Traumatologia [INOT] and Banco de Protesis), from July 2001 through August 2007

  14. Fluorocarbon seal replaces metal piston ring in low density gas environment

    Science.gov (United States)

    Morath, W. D.; Morgan, N. E.

    1967-01-01

    Reinforced fluorocarbon cupseal, which provides an integral lip-type seal, replaces the metal piston rings in piston-cylinder configurations used in the compression of low density gases. The fluorocarbon seal may be used as cryogenic compressor piston seals.

  15. Is radiation superior to indomethacin to prevent heterotopic ossification in acetabular fractures?: a systematic review.

    NARCIS (Netherlands)

    Blokhuis, T.J.; Frolke, J.P.M.

    2009-01-01

    Heterotopic ossification is a well-known complication after fixation of an acetabular fracture. Indomethacin and radiation therapy are used as prophylaxis to prevent heterotopic ossification. It is unclear, however, whether either is superior, although this may relate to lack of power in individual

  16. Direct and indirect costs of surgically treated pelvic fractures.

    Science.gov (United States)

    Aprato, Alessandro; Joeris, Alexander; Tosto, Ferdinando; Kalampoki, Vasiliki; Stucchi, Alessandro; Massè, Alessandro

    2016-03-01

    Pelvic fractures requiring surgical fixation are rare injuries but present a great societal impact in terms of disability, as well as economic resources. In the literature, there is no description of these costs. Main aim of this study is to describe the direct and indirect costs of these fractures. Secondary aims were to test if the type of fracture (pelvic ring injury or acetabular fracture) influences these costs (hospitalization, consultation, medication, physiotherapy sessions, job absenteeism). We performed a retrospective study on patients with surgically treated acetabular fractures or pelvic ring injuries. Medical records were reviewed in terms of demographic data, follow-up, diagnosis (according to Letournel and Tile classifications for acetabular and pelvic fractures, respectively) and type of surgical treatment. Patients were interviewed about hospitalization length, consultations after discharge, medications, physiotherapy sessions and absenteeism. The study comprised 203 patients, with a mean age of 49.1 ± 15.6 years, who had undergone surgery for an acetabular fracture or pelvic ring injury. The median treatment costs were 29.425 Euros per patient. Sixty percent of the total costs were attributed to health-related work absence. Median costs (in Euros) were 2.767 for hospitalization from trauma to definitive surgery, 4.530 for surgery, 3.018 for hospitalization in the surgical unit, 1.693 for hospitalization in the rehabilitation unit, 1.920 for physiotherapy after discharge and 402 for consultations after discharge. Total costs for treating pelvic ring injuries were higher than for acetabular fractures, mainly due to the significant higher costs of pelvic injuries regarding hospitalization from trauma to definitive surgery (p fractures are associated with both high direct costs and substantial productivity loss.

  17. [Acetabular anteversion angle of the hip in the Mexican adult population measured with computed tomography].

    Science.gov (United States)

    Rubalcava, J; Gómez-García, F; Ríos-Reina, J L

    2012-01-01

    Knowledge of the radiogrametric characteristics of a specific skeletal segment in a healthy population is of the utmost clinical importance. The main justification for this study is that there is no published description of the radiogrametric parameter of acetabular anteversion in a healthy Mexican adult population. A prospective, descriptive and cross-sectional study was conducted. Individuals of both genders older than 18 years and orthopedically healthy were included. They underwent a two-dimensional axial tomographic study of both hips to measure the acetabular anteversion angles. The statistical analysis consisted of obtaining central trend and scatter measurements. A multivariate analysis of variance (ANOVA) and statistical significance were performed. 118 individuals were studied, 60 males and 58 females, with a mean age of 47.7 +/- 16.7, and a range of 18-85 years. The anteversion of the entire group was 18.6 degrees + 4.1 degrees. Anteversion in males was 17.3 degrees +/- 3.5 degrees (10 degrees - 25 degrees) and in females 19.8 degrees +/- 4.7 degrees (10 degrees - 31 degrees). There were no statistically significant differences (p right and left anteversion in the entire group. However, there were statistically significant differences (p > or = 0.005) both in the right and left sides when males and females were compared. Our study showed that there are great variations in the anteversion ranges of a healthy population. When our results are compared with those published by other authors the mean of most measurements exceeds 15 degrees. This should be useful to make therapeutic decisions that involve acetabular anteversion.

  18. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2014-01-01

    Full Text Available Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC. Twenty-nine patients (32 implants died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years. There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years, with Paprosky IIIA (27 cases and IIIB (38 cases acetabular bone defects. Nine cages required rerevision because of infection (3, aseptic loosening (5, and flange breakage (1. The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P<0.001. Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival.

  19. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    Science.gov (United States)

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  20. LABORATORY EVALUATION ON PERFORMANCE OF GLASS FIBER REINFORCED PLASTIC MORTAR PIPE CULVERTS

    OpenAIRE

    Huawang Shi; Lianyu Wei

    2018-01-01

    This paper investigated the performance and behaviour of glass fiber reinforced plastic mortar (FRPM) pipes under different loading conditions. FRPM pipes with inner diameter of 1500 mm were prefabricated in factory. Mechanics performance testing (ring and axial compressive strength and elastic modulus), stiffness and fatigue test were carried out in laboratory. Ring stiffness test provided pipe stiffness (PS) which is a function of geometry and material type of pipe through parallel plate lo...

  1. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    Science.gov (United States)

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  2. Efficient radiologic diagnosis of pelvic and acetabular trauma; Rationelle bildgebende Diagnostik von Becken- und Azetabulumverletzungen

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F.; Mildenberger, P.; Thelen, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Rommens, P.M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2000-01-01

    In spite of the widespread availability of CT scanners, conventional X-ray radiographs remain the basic imaging modality in patients with pelvic and/or acetabular trauma. However, the extent of their use will depend on local utilities (e.g., availability of CT scanners) and on the patient's clinical condition. Regarding the inaccuracy of conventional radiography in the diagnosis of injuries of the dorsal pelvic ring and of the acetabulum, computed tomography represents the most important imaging modality in the clinically stable patient. CT provides an exact staging of the extent of trauma and allows for differentiation of pelvic instabilities. CT clearly demonstrates the severity of acetabular trauma and is superior in the detection of local complicating factors, i.e., impressions fractures and (sub-)luxations of the femoral head as well as free intraarticular fragments. CT findings provide the basis for definite treatment regimens of the injured patient. By extension of the examination, all relevant organs and systems (craniospinal, cardiovascular, gastrointestinal, respiratory, genitourinary) can be imaged during one session. The speed of spiral CT scanners and their diagnostic accuracy will play a major role in the management of, especially, polytraumatized patients. The indication for angiography with the option of therapeutic embolization exists if a pelvic bleeding persists even after reposition and operative fixation of the injury. (orig.) [German] Bei der Klaerung einer Verletzung des Beckens oder des Azetabulums stellen konventionelle Uebersichtsaufnahmen weiterhin die Basis der bildgebenden Diagnostik dar. Art und Umfang werden bestimmt von lokalen Gegebenheiten (z.B. Verfuegbarkeit von CT-Geraeten) sowie vom klinischen Zustand des Patienten. Aufgrund der diagnostischen Ungenauigkeit der konventionellen Roentgendiagnostik gerade im Bereich des stabilitaetsbedeutsamen dorsalen Beckenringes und des Azetabulums schliesst sich beim klinisch stabilen

  3. Acetabular labral tears: contrast-enhanced MR imaging under continuous leg traction

    Energy Technology Data Exchange (ETDEWEB)

    Nishii, T. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Nakanishi, K. [Dept. of Radiology, Osaka Univ. Medical School, Suita (Japan); Sugano, N. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan); Naito, H. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Tamura, S. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Ochi, T. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan)

    1996-05-01

    The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning. (orig./MG)

  4. Surgical treatment of isolated aseptic acetabular loosening of the hip joint

    Directory of Open Access Journals (Sweden)

    Zvereva К.Р.

    2017-09-01

    Full Text Available Aseptic acetabular loosening is one of the most common complications of primary hip arthroplasty Its treatment is possible in the volume of replacement of only the endoprosthesis cup with the preservation of a stable correctly oriented femoral component. The sequence of actions consists of provision of access to the acetabulum component and its replacement, after which the necessary offset is selected by changing the size of the head and installing a new pair of friction. Currently, the vast majority of the installed heads during the primary and revision hip replacement have a standard size forthe cone of the femoral component 12/14mm. According to the observations, in 3% of cases, there are femoral components with non-standard cone sizes 11/13 mm, usually established 7-8 years ago. The absence of heads forthe necessary cone leads to the need to replace the stable correctly oriented femoral component, which is accompanied by an increase in the time of intervention, the volume of intraoperative blood loss and the risk of intraopera-tive peri-prosthetic fracture. We represent the clinical case of a 75-year-old patient with a dislocation of the acetabular component and a stable correctly oriented femoral component, which during the audit intervention due to the lack of heads for an irregular cone size, total replacement of the components was made.

  5. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    Science.gov (United States)

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  6. Reinforced seal component

    International Nuclear Information System (INIS)

    Jeanson, G.M.; Odent, R.P.

    1980-01-01

    The invention concerns a seal component of the kind comprising a soft sheath and a flexible reinforcement housed throughout the entire length of the sheath. The invention enables O ring seals to be made capable of providing a radial seal, that is to say between two sides or flat collars of two cylindrical mechanical parts, or an axial seal, that is to say between two co-axial axisymmetrical areas. The seal so ensured is relative, but it remains adequately sufficient for many uses, for instance, to ensure the separation of two successive fixed blading compartments of axial compressors used in gas diffusion isotope concentration facilities [fr

  7. Percutaneous Fixation of Anterior Column Acetabular Fracture in a Renal Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Halil Ceylan

    2013-01-01

    Full Text Available Renal transplantation, performed per million population, ranges from 30 to 60 in developed countries. The transplanted kidney is generally placed in iliac fossa; therefore the treatment procedure of the pelvic trauma in these patients should be selected carefully. The gold standard technique for the treatment of displaced acetabulum fractures is open reduction and internal fixation. Our patient had received a living-related-donor renal transplant due to chronic renal failure. In the second year of transplantation, she had been injured in a motor-vehicle accident, and radiographs showed a right acetabular anterior column fracture and left pubic rami fractures. The patient was treated with percutaneous fixation techniques and at one year of postoperative period there was no evidence of degenerative signs and the clinical outcome was good. Beside having the advantage of avoiding dissection through the iliac fossa by the standard ilioinguinal approach, percutaneous techniques, with shorter surgical time, decreasing soft tissue disruption, and the potential for early discharge from hospital might be ideal for a renal transplant recipient carrying a higher risk of infection. Percutaneous fixation of selected acetabular fractures in a renal transplant recipient would presumably have the potential to decrease the morbidity associated with traditional open surgical procedures.

  8. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    Science.gov (United States)

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  9. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    Science.gov (United States)

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.

  10. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    Science.gov (United States)

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  11. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    LENUS (Irish Health Repository)

    Kelly, M E

    2013-03-13

    BACKGROUND: Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. AIM: To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. METHODS: Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. RESULTS: 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. CONCLUSION: Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient".

  12. Effects of Titanium Mesh Surfaces-Coated with Hydroxyapatite/β-Tricalcium Phosphate Nanotubes on Acetabular Bone Defects in Rabbits

    Directory of Open Access Journals (Sweden)

    Thuy-Duong Thi Nguyen

    2017-07-01

    Full Text Available The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05. CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo.

  13. Profundization of acetabular cup uncemented in total substitution of hip in-patient with acetabular dysplasia - Experience university hospital - Clinica San Rafael

    International Nuclear Information System (INIS)

    Dimian Mayorga, Omar David; Sandoval Daza, Alejandro; Vargas Turriago, Marcela; Perez Torres, Javier

    2005-01-01

    14 patients with acetabular dysplasia were treated at Hospital Universitario Clinica San Rafael with total hip arthroplasty with uncemented cup internization. According to Crowe classification, one was type 1, eight were type 2 and five were type 3. The average follow up was twenty-four months. The Harris hip score was used for the clinical evaluation with a pre operative average of 35 points and 37 points post operative. The average cup internization was four millimeters, with an average cup protrutio of 47% and an average of cup coverage of 81%. The average internization of the femoral head's center was 26mm. screws for cup fixation were used in 3 patients. We did not have complications nor implant revision at the time of follow up

  14. Pelvic and acetabular trauma care in Ireland: the past, present and future

    LENUS (Irish Health Repository)

    Queally, JM

    2017-08-01

    Pelvic injuries involve injury to the osseo-ligamentous ring structure of the pelvis or the acetabulum of either hip joint. They are typically caused by high-energy trauma and may be associated with significant morbidity or mortality at the time of injury due to excessive haemorrhage and associated abdominal, chest or head injuries with mortality rates of 8.6% to 19.1% reported for closed injuries and rates of up to 50% reported for open injuries1. Despite the severity of these injuries and the potential for poor long term outcomes, these injuries were managed with non-surgical treatment until the middle of the 20th century. Treatment typically involved prolonged bed rest, traction or compression devices, pelvic slings and spica casts with poor outcomes due to persistent pelvic deformity in pelvic injures and early osteoarthritis in acetabular fractures2,3. In the 1930’s, with the advent of radiography, significant progress was made in terms of understanding injury patterns, subsequent displacement and the significance of pelvic instability and deformity post injury. Along with the improved definitive management of pelvic injuries, similar progress was made with the immediate management of life-threatening haemodynamic instability and resuscitation with a significant improvement in mortality rate achieved over the past 50 years3,4. In contemporary trauma care, to ensure optimal outcomes, pelvic trauma is now considered a subspecialty practised in tertiary centres by fellowship trained specialists. Herein we describe the evolution of pelvic trauma care in Ireland over the past 30 years in an overall context of improved international paradigms of care and discuss potential future developments

  15. New proposal of mechanical reinforcement structures to annular REBaCuO bulk magnet for compact and cryogen-free NMR spectrometer

    Science.gov (United States)

    Fujishiro, H.; Takahashi, K.; Naito, T.; Yanagi, Y.; Itoh, Y.; Nakamura, T.

    2018-07-01

    We have proposed new reinforcement structures using an aluminum alloy ring to the annular REBaCuO bulks applicable to compact and cryogen-free 400 MHz (9.4 T) nuclear magnetic resonance (NMR) spectrometer using a numerical simulation of mechanical stress. The thermal compressive stress, σθcool, which was applied to the annular bulks during cooling due to the difference of thermal expansion coefficient between bulk and aluminum alloy, became fairly enhanced at the surface of the uppermost bulk for the new reinforcement structures, compared to the conventional reinforcement with the same height as the annular bulk, in which the compressive σθcool value was reduced. During field-cooled magnetization (FCM), the electromagnetic hoop stress, σθFCM, became the maximum at the innermost edge of the uppermost ring bulk at intermediate time step. The actual total hoop stress, σθ (= σθcool + σθFCM), due to both cooling and FCM processes was also analyzed and the new ring structures are fairly effective to reduce the σθ value and became lower than the fracture strength of the bulk. The new reinforcement structures have a possibility to avoid the fracture of the bulks and to realize a 400 MHz NMR spectrometer.

  16. Porous metal revision shells for management of contained acetabular bone defects at a mean follow-up of six years: a comparison between up to 50% bleeding host bone contact and more than 50% contact.

    Science.gov (United States)

    Sternheim, A; Backstein, D; Kuzyk, P R T; Goshua, G; Berkovich, Y; Safir, O; Gross, A E

    2012-02-01

    We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years' follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth.

  17. Experimental buckling investigation of ring-stiffened cyclindrical shells under unsymmetrical axial loads

    International Nuclear Information System (INIS)

    Baker, W.E.; Bennett, J.G.; Babcock, C.D.

    1983-01-01

    Six steel shells having nuclear containment-like features were fabricated and loaded to failure with an offset axial load. The shells of R/t = 500 buckled plastically. Four of the shells had reinforced circular cutouts. These penetrations were sized to cut no ring-stiffener, a single, two- or three-ring stiffeners. Reinforcing and framing around the penetrations were based upon the area-replacement rule of the applicable portion of the American Society for Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and were of a design to simulate actual practice for nuclear steel containments. Prior to testing, imperfections were measured and strain gages were applied to determine information on load distribution at the ends of the cylinder and strain fields at areas likely to buckle. Buckling loads were determined for an axial load applied with an eccentricity of R/2 where R is the cylinder radius

  18. Electronic properties of superlattices on quantum rings.

    Science.gov (United States)

    da Costa, D R; Chaves, A; Ferreira, W P; Farias, G A; Ferreira, R

    2017-04-26

    We present a theoretical study of the one-electron states of a semiconductor-made quantum ring (QR) containing a series of piecewise-constant wells and barriers distributed along the ring circumference. The single quantum well and the superlattice cases are considered in detail. We also investigate how such confining potentials affect the Aharonov-Bohm like oscillations of the energy spectrum and current in the presence of a magnetic field. The model is simple enough so as to allow obtaining various analytical or quasi-analytical results. We show that the well-in-a-ring structure presents enhanced localization features, as well as specific geometrical resonances in its above-barrier spectrum. We stress that the superlattice-in-a-ring structure allows giving a physical meaning to the often used but usually artificial Born-von-Karman periodic conditions, and discuss in detail the formation of energy minibands and minigaps for the circumferential motion, as well as several properties of the superlattice eigenstates in the presence of the magnetic field. We obtain that the Aharonov-Bohm oscillations of below-barrier miniband states are reinforced, owing to the important tunnel coupling between neighbour wells of the superlattice, which permits the electron to move in the ring. Additionally, we analysis a superlattice-like structure made of a regular distribution of ionized impurities placed around the QR, a system that may implement the superlattice in a ring idea. Finally, we consider several random disorder models, in order to study roughness disorder and to tackle the robustness of some results against deviations from the ideally nanostructured ring system.

  19. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  20. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    Directory of Open Access Journals (Sweden)

    Xuezhi Lin

    2018-01-01

    Full Text Available Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM but the biocompatibility of these three-dimensional printing (3D-printed plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  1. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup Análisis del desgaste de la articulación cabeza femoral–copa acetabular mediante simulación experimental con máquina perno-disco

    Directory of Open Access Journals (Sweden)

    Beltrán-Fernandez Juan Alfonso

    2008-07-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.Este trabajo presenta un estudio que permite establecer la vida útil esperada de un sistema prostético de cadera para el caso del fenotipo mexicano. En primera instancia se determinó la distancia total equivalente de deslizamiento y las condiciones de carga entre el componente femoral y la copa acetabular bajo condiciones normales de carga. Posteriormente, se desarrolló una simulación experimental para la realización de un ensayo tribológico en una máquina de desgaste del tipo Perno sobre Disco (Pin on Disk, POD. Este ensayo sometió al conjunto fabricado en acero inoxidable AISI

  2. Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs

    OpenAIRE

    Kneif, D.; Downing, M.; Ashcroft, G. P.; Gibson, P.; Knight, D.; Ledingham, W.; Hutchison, J.

    2005-01-01

    Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreem...

  3. [Biomechanical significance of the acetabular roof and its reaction to mechanical injury].

    Science.gov (United States)

    Domazet, N; Starović, D; Nedeljković, R

    1999-01-01

    The introduction of morphometry into the quantitative analysis of the bone system and functional adaptation of acetabulum to mechanical damages and injuries enabled a relatively simple and acceptable examination of morphological acetabular changes in patients with damaged hip joints. Measurements of the depth and form of acetabulum can be done by radiological methods, computerized tomography and ultrasound (1-9). The aim of the study was to obtain data on the behaviour of acetabular roof, the so-called "eyebrow", by morphometric analyses during different mechanical injuries. Clinical studies of the effect of different loads on acetabular roof were carried out in 741 patients. Radiographic findings of 400 men and 341 women were analysed. The control group was composed of 148 patients with normal hip joints. Average age of the patients was 54.7 years and that of control subjects 52.0 years. Data processing was done for all examined patients. On the basis of our measurements the average size of female "eyebrow" ranged from 24.8 mm to 31.5 mm with standard deviation of 0.93 and in men from 29.4 mm to 40.3 mm with standard deviation of 1.54. The average size in the whole population was 32.1 mm with standard deviation of 15.61. Statistical analyses revealed high correlation coefficients between the age and "eyebrow" size in men (r = 0.124; p 0.05). The examination of the size of collodiaphysial angle and length of "eyebrow" revealed that "eyebrow" length was in inverse proportion to the size of collodiaphysial angle (r = 0.113; p 0.05) and female (r = 0.005; p > 0.05) patients. The "eyebrow" length was proportionally dependent on the size of the shortened extremity in all examined subjects. This dependence was statistically significant both in female (r = 0.208; p < 0.05) and male (r = 0.193; p < 0.05) patients. The study revealed that fossa acetabuli was forward and downward laterally directed. The size, form and cross-section of acetabulum changed during different

  4. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    Science.gov (United States)

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (Pcup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Application research of ferrous matrix composites in roller ring used in high-speed wire/bar rolling mill

    International Nuclear Information System (INIS)

    Song Yanpei; Li Xiuqing; Bi Shuangxu

    2010-01-01

    Research highlights: → A composite structure roller rings was fabricated by centrifugal casting. → The roller rings consisted of outer WCP/Fe-C composites layer and inner Fe-C alloy matrix. → Hardness attained to HRA80-85 in the composites layer, and HRA73-76 in inner Fe-C alloy matrix where the toughness was over 8 J/cm 2 . → The wear resistance of the roller rings excelled that of high-speed steel, and approached to that of the WC hard alloy roll. → The production cost of the WCP/Fe-C composites roller ring decreased by 50%. - Abstract: Tungsten carbide particle (WC P ) reinforced ferrous matrix composites roller rings were fabricated by centrifugal casting. The microstructures, properties and application effect of the composites roller rings were investigated by SEM, TEM and various property testers. The experimental results show that the WC P were uniformly distributed in outer reinforced-layer (working-layer) of 20-50 mm in thickness and their volume fraction reached 60-80 vol.%; there was a good interface bonding between WC P and Fe-C alloy without any reaction products; hardness attained to HRA80-85 in working-layer, and HRA73-76 in inner ferrous matrix where the toughness was over 8 J/cm 2 ; the wear resistance of the composites roller rings excels that of high-speed steel; service life of the composites parts approached to that of the WC hard alloy roll when the same WC P -volume-fraction in working-layer were obtained for both of them, but the production cost of the WC P /Fe-C composites roller ring decreased by 50%.

  6. Initial stability of a highly porous titanium cup in an acetabular bone defect model.

    Science.gov (United States)

    Yoshimoto, Kensei; Nakashima, Yasuharu; Wakiyama, Miyo; Hara, Daisuke; Nakamura, Akihiro; Iwamoto, Mikio

    2018-04-12

    The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. The maximum torque of a highly porous titanium cup, with a pore size of 640 μm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects. Copyright © 2018. Published by Elsevier B.V.

  7. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    Science.gov (United States)

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  8. Experimental buckling investigation of ring-stiffened cylindrical shells under unsymmetrical axial loads

    International Nuclear Information System (INIS)

    Baker, W.E.; Babock, C.D.; Bennett, J.G.

    1983-01-01

    Six steel shells having nuclear containment-like features were fabricated and loaded to failure with an offset axial load. The shells of R/t = 500 buckled plastically. Four of the shells had reinforced circular cutouts. These penetrations were sized to cut no ring-stiffener, a single, two- or three-ring stiffeners. Reinforcing and framing around the penetrations were based upon the area-replacement rule of the applicable portion of the American Society for Mechanical Engineers (ASME) Boiler and Pressure Vessel Code and were of a design to stimulate actual practice for nuclear steel containments. Prior to testing, imperfections were measured and strain gages were applied to determine information on load distribution at the ends of the cylinder and strain fields at areas likely to buckle. Buckling loads were determined for an axial load applied with an eccentricity of R/2 where R is the cylinder radius. The results showed that the buckling load and mode for the shell having a penetration that did not cut a ring stiffener were essentially the same as those for the unpenetrated shell. The buckling loads for the penetrated shells in which stiffeners were interrupted were less than that for the unpenetrated shells. Results of all tests are compared to numerical solutions carried out using a nonlinear collapse analysis and to the predictions of ASME Code Case N-284

  9. The acetabular fossa hot spot on {sup 18}F-FDG PET/CT: epidemiology, natural history, and proposed etiology

    Energy Technology Data Exchange (ETDEWEB)

    Kubicki, Shelby L. [Trinity University, San Antonio, TX (United States); Richardson, Michael L. [University of Washington, Department of Radiology, Seattle, WA (United States); Martin, Thomas [X-Ray Associates of New Mexico, Department of Radiology, Albuquerque, NM (United States); Rohren, Eric [The University of Texas M.D. Anderson Cancer Center, Department of Diagnostic Radiology, Division of Nuclear Medicine, Houston, TX (United States); Wei, Wei [The University of Texas M.D. Anderson Cancer Center, Department of Biostatistics, Houston, TX (United States); Amini, Behrang [The University of Texas M.D. Anderson Cancer Center, Department of Diagnostic Radiology, Division of Musculoskeletal Radiology, Houston, TX (United States)

    2015-01-15

    To describe a benign focus of increased activity in the acetabular fossa (the acetabular fossa hot spot, AFHS) on {sup 18}F-FDG PET/CT that can mimic a neoplasm. {sup 18}F-FDG PET/CT images from four patient populations were examined. Group 1 (n = 13) was collected from a search of radiology reports and used to define the AFHS and for hypothesis generation. Group 2 (n = 1,150) was used for prevalence of AFHS. Group 3 (n = 1,213) had PET/CT and MRI pelvis within a week of each other and was used to correlate metabolic and anatomic findings. Group 4 (n = 100) was used to generate the control group. Data were collected on demographics, common comorbidities, underlying cancer diagnosis and status, and hip symptoms. Prevalence of AFHS was 0.36 % (95 % CI 0.10-0.91 %). None progressed to malignancy or was associated with cancer status. The majority (71 %) were on the left, and 6 % were bilateral. Mean SUV{sub max} of the AFHS was 4.8 (range, 2.7-7.8). Male patients were more likely to have the AFHS (OR = 8.69, 95 % CI 1.88-40.13). There was no difference with respect to other collected data, including hip symptoms. Average minimum duration of AFHS was 346 days (range, 50-1,010 days). Readers did not detect corresponding hip abnormalities on MRIs. AFHS is a benign finding that may be caused by subclinical ligamentum teres injury, focal synovitis, or degeneration of acetabular fossa fat. Despite uncertainty regarding its etiology, recognition of AFHS as a benign finding can prevent morbidity associated with unnecessary biopsy or initiation of therapy. (orig.)

  10. Radiologic analysis of femoral acetabular impingement: from radiography to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dwek, Jerry R. [University of California at San Diego, Department of Radiology, Rady Children' s Hospital and Health Center, San Diego, CA (United States); San Diego Imaging, San Diego, CA (United States); Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Chung, Christine B. [University of California at San Diego, Department of Radiology, San Diego, CA (United States)

    2013-03-15

    Femoral acetabular impingement is a set of morphologic abnormalities that are considered to be a major cause of degenerative disease in the hip joint. Early changes are already present in adolescence when it is the pediatric radiologist who must assess current damage with the aim of averting progression to more severe and debilitating osteoarthritis. A multimodality approach is used for diagnosis, that includes conventional radiography and CT to assess the osseous structures. MR arthrography is the primary advanced imaging modality for assessment of morphologic changes as well as injuries of the labrum and articular cartilage. Details of radiologic imaging are offered to guide the radiologist and provide an avenue for the accurate description of the osseous and articular alterations and injury. (orig.)

  11. A new technique for radiographic measurement of acetabular cup orientation.

    Science.gov (United States)

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  12. Long-term results of uncemented alumina acetabular implants.

    Science.gov (United States)

    Boehler, M; Knahr, K; Plenk, H; Walter, A; Salzer, M; Schreiber, V

    1994-01-01

    We report the clinical and tribological performance of 67 ceramic acetabular prostheses implanted between 1976 and 1979 without bone cement. They articulated with ceramic femoral heads mounted on mental femoral stems. After a mean elapsed period of 144 months, 59 sockets were radiographically stable but two showed early signs and six showed late signs of loosening. Four of the loose sockets have been revised. Histological analysis of the retrieved tissue showed a fibrous membrane around all the implants, with fibrocartilage in some. There was no bone ingrowth, and the fibrous membrane was up to 6 mm thick and infiltrated with lymphocytes, plasma cells, and macrophages. Intra- and extracellular birefringent wear particles were seen. Tribological analysis showed total wear rates in two retrieved alumina-on-alumina joints of 2.6 microns per year in a stable implant and 68 microns in a loose implant. Survival analysis showed a revision rate of 12.4% at 136 months.

  13. Delayed cementless total hip arthroplasty for neglected dislocation of hip combined with complex acetabular fracture and deficient bone stock

    Directory of Open Access Journals (Sweden)

    Gavaskar Ashok S

    2012-12-01

    Full Text Available 【Abstract】Total hip arthroplasty (THA for an un-treated acetabular fracture is technically challenging and the long-term result is not so favorable. A 45-year-old fe-male patient with untreated column and comminuted poste-rior wall fracture of the acetabulum was treated in our insti-tution by reconstruction of the posterior wall using iliac strut autograft and plate stabilization of the posterior col-umn with cancellous grafting and cementless THA in a single stage. At 3 years’ follow-up, the patient was independently mobile without limb length discrepancy. Radiological evalu-ation showed well integrated components and bone grafts. No evidence of aseptic loosening or osteolysis was found. This report aims to emphasize that bony acetabular recon-struction allows the use of primary hip components, which improves prosthesis longevity and preserves bone stock for a future revision. Key words: Acetabulum; Fractures, bone; Hip dislocation; Arthroplasty, replacement, hip

  14. A structural design of the multi-ringed seismic support for PCPV

    International Nuclear Information System (INIS)

    Muto, Kiyoshi; Ujiie, Koji.

    1979-01-01

    This report describes the multi-ringed cylindrical support newly developed as the supporting structure for a Prestressed Concrete Pressure Vessel. This support is composed of several thin cylinders of concentric circles, which are made of reinforced concrete or steel reinforced concrete. The characteristics of the support is such that it can allow two contradictory conditions to occur. That is, it can follow smoothly the radial displacement of PCPV induced by inner pressure, inner heat and etc. At the same time, it has enough rigidity to bear the earthquake forces from PCPV and to transmit them to the ground with certainty. The shape, characteristics and structural design of the support are described hereunder. (author)

  15. Influence of soft tissue in the assessment of the primary fixation of acetabular cup implants using impact analyses.

    Science.gov (United States)

    Bosc, Romain; Tijou, Antoine; Rosi, Giuseppe; Nguyen, Vu-Hieu; Meningaud, Jean-Paul; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Haiat, Guillaume

    2018-06-01

    The acetabular cup (AC) implant primary stability is an important determinant for the success of cementless hip surgery but it remains difficult to assess the AC implant fixation in the clinic. A method based on the analysis of the impact produced by an instrumented hammer on the ancillary has been developed by our group (Michel et al., 2016a). However, the soft tissue thickness present around the acetabulum may affect the impact response, which may hamper the robustness of the method. The aim of this study is to evaluate the influence of the soft tissue thickness (STT) on the acetabular cup implant primary fixation evaluation using impact analyses. To do so, different AC implants were inserted in five bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the AC implant was impacted 25 times with 10 and 30 mm of soft tissues positioned underneath the sample. The averaged indicator I m was determined based on the amplitude of the signal for each configuration and each STT and the pull-out force was measured. The results show that the resonance frequency of the system increases when the value of the soft tissue thickness decreases. Moreover, an ANOVA analysis shows that there was no significant effect of the value of soft tissue thickness on the values of the indicator I m (F = 2.33; p-value = 0.13). This study shows that soft tissue thickness does not appear to alter the prediction of the acetabular cup implant primary fixation obtained using the impact analysis approach, opening the path towards future clinical trials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Pelvic reconstructions following peri-acetabular bone tumour resections using a cementless ice-cream cone prosthesis with dual mobility cup.

    Science.gov (United States)

    Issa, Samir-Pierre; Biau, David; Babinet, Antoine; Dumaine, Valérie; Le Hanneur, Malo; Anract, Philippe

    2018-01-27

    Despite numerous reconstructive techniques and prosthetic devices, pelvic reconstructions following peri-acetabular malignant tumours resections are highly challenging. In the present study, we describe our experience with the Integra® (Lépine, Genay, France) ice-cream cone prosthesis in such indications. The objective was to assess the mid-term outcomes of this device. Twenty-four patients' chart with peri-acetabular malignant tumours, who underwent types II or II + III peri-acetabular resections according to Enneking and Dunham with subsequent reconstruction using the Integra® prosthesis between February 2009 and February 2015, were reviewed. Seventeen cases were primary surgeries and seven cases were revisions (i.e., failures of previous reconstructions for pelvic tumours). All living patients with the prosthesis implanted were functionally assessed, using the musculoskeletal tumour society (MSTS) and Postel-Merle d'Aubigné (PMA) scores. After a mean follow-up of 49 ± 26 months (range, 8 to 94 months), 21 patients were alive (88%), including 15 patients continuously disease-free (63%). MSTS and PMA scores averaged 72 ± 13% (range, 43 to 87%) and 14.6 ± 2.6 (range, 9 to 18), respectively. Fourteen patients (58%) presented at least one complication during follow-up, including four cases of deep infection (17%), four cases of dislocation (17%), and two mechanical failures (8%). At 5 years, the implant survival rate was 75%. In comparison to previous reconstructive techniques that we used in similar indications, functional and oncologic outcomes were improved with the Integra® implant. However, as commonly observed in pelvic bone tumour surgery, complication rates remain significant. Therapeutic, Level IV-Retrospective Cases Series.

  17. Post-operative observation of ilio-apophyseal transplants on the basis of radiography, computed tomography, autoradiography and histological assessment

    International Nuclear Information System (INIS)

    Klatt, U.

    1987-01-01

    A study in 25 rabbits, in which the acetabular roof was reinforced by inserting a wedge-shaped autologous tissue fragment of the apophysis, led to the following conclusions: That complete healing and ossification of the implant took place within the observation period; that radiography, computed tomography, autoradiography and histology consistently provided evidence in confirmation of ossification; that a wedge-shaped fragment of apophyseal cartilage is a suitable material for plastic surgery in the acetabular roof. (TRV) [de

  18. Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty.

    Science.gov (United States)

    Ozden, Vahit Emre; Dikmen, Goksel; Beksac, Burak; Tozun, Ismail Remzi

    2018-05-01

    Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage. Copyright © 2018 The Japanese

  19. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  20. Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rader, Kevin; Palm, Henrik

    2015-01-01

    segment to measure wear and acetabular cup stability. The standard deviation multiplied by the critical value (from a t distribution) established the precision of each method. Results - Due to the imprecision of the automated edge detection, the shell-only method was least desirable. The shell + liner...

  1. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    Science.gov (United States)

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  2. Failure mechanisms and closed reduction of a constrained tripolar acetabular liner.

    Science.gov (United States)

    Robertson, William J; Mattern, Christopher J; Hur, John; Su, Edwin P; Pellicci, Paul M

    2009-02-01

    Unlike traditional bipolar constrained liners, the Osteonics Omnifit constrained acetabular insert is a tripolar device, consisting of an inner bipolar bearing articulating within an outer, true liner. Every reported failure of the Omnifit tripolar implant has been by failure at the shell-bone interface (Type I failure), failure at the shell-liner interface (Type II failure), or failure of the locking mechanism resulting in dislocation of the bipolar-liner interface (Type III failure). In this report we present two cases of failure of the Omnifit tripolar at the bipolar-femoral head interface. To our knowledge, these are the first reported cases of failure at the bipolar-femoral head interface (Type IV failure). In addition, we described the first successful closed reduction of a Type IV failure.

  3. Status of PF-ring commissioning after the reconstruction for the straight-sections upgrade

    International Nuclear Information System (INIS)

    Tanimoto, Yasunori; Miyauchi, Hiroshi; Honda, Tohru; Kobayashi, Yukinori

    2006-01-01

    The upgrade project of the straight sections at the PF-ring enables the reinforcement of insertion devices and their beamlines. As a main part of this project, a large-scale reconstruction of the storage ring was carried out from March to September in 2005. The lattice configuration was modified to create short straight sections of 1.4 m and to extend the existing straight sections. Optical functions of the short sections were optimized for short-gap mini-pole undulators as X-ray sources. The first mini-pole undulator SGU no.17 has been operated for a protein crystallography. A recommissioning of the ring was conducted for about one month, and user experiments were restarted on 18th October 2005 according to schedule. The recovery of the beam lifetime due to the process of the vacuum scrubbing has been favorably progressed. (author)

  4. High proximal migration in cemented acetabular revisions operated with bone impaction grafting; 47 revision cups followed with RSA for 17 years.

    Science.gov (United States)

    Mohaddes, Maziar; Herberts, Peter; Malchau, Henrik; Johanson, Per-Erik; Kärrholm, Johan

    2017-05-12

    Bone impaction grafting is a biologically and mechanically appealing option in acetabular revision surgery, allowing restitution of the bone stock and restoration of the biomechanics. We analysed differences in proximal migration of the revision acetabular components when bone impaction grafting is used together with a cemented or an uncemented cup. 43 patients (47 hips), revised due to acetabular loosening and judged to have less than 50% host bone-implant contact were included. The hips were randomised to either an uncemented (n = 20) or a cemented (n = 27) revision cup. Radiostereometry and radiography was performed postoperatively, at 3 and 6 months, 1, 2, 3, 5, 7, 10 and 13 and 17 years postoperatively. Clinical follow-up was performed at 1, 2 and 5 years postoperatively and thereafter at the same interval as in the radiographic follow-up. There were no differences in the base line demographic data between the 2 groups. At the last follow-up (17 years) 14 hips (10 cemented, 4 uncemented) had been re-revised due to loosening. 3 additional cups (1 uncemented and 2 cemented) were radiographically loose. There was a higher early proximal migration in the cemented cups. Cups operated on with cement showed a higher early migration measured with RSA and also a higher number of late revisions. The reason for this is not known, but factors such as inclusion of cases with severe bone defects, use of smaller bone chips and issues related to the impaction technique might have had various degrees of influence.

  5. Modifications to the application of pressure to a quarter of the circumference of panel rings (tests 54 and 55)

    Energy Technology Data Exchange (ETDEWEB)

    Van Duyse, H [INIEX

    1978-01-01

    Tests 54 and 55 were carried out on rings made up of the usual type of panel. Test 54 involved panels manufactured at Zolder and Test 55 involved those manufactured at Beringen. Both types of ring are 20 cm thick, 64 cm wide and have an internal diameter of 4.20 m. The tests involved application of pressure to one quarter of the circumference, the remainder of the ring being subject to restraint against the steel testing frame. Timber chocks were inserted between the ring and the frame. The reinforcements tested were those used with the normal type of panel. An account of deformation of the ring, cracking of the panels, and deformation of the concrete is given. Tables and figures summarizing the results achieved are included. Maximum load prior to breaking was 292 t in the case of the Zolder ring and 293 t in the case of the Beringen ring; initial cracking occurred at 35 and 30 t, respectively. (In French and in Dutch)

  6. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Schedel, H.; Stoeckle, U.; Wellmann, A.; Beier, J.; Wicht, L.; Hoffmann, R.; Felix, R.

    1996-01-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [de

  7. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

    Science.gov (United States)

    Zhang, Yuan Z; Chen, Bin; Lu, Sheng; Yang, Yong; Zhao, Jian M; Liu, Rui; Li, Yan B; Pei, Guo X

    2011-12-01

    The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05). The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate

  8. Supra-Acetabular Brown Tumor due to Primary Hyperparathyroidism Associated with Chronic Renal Failure

    Directory of Open Access Journals (Sweden)

    Rosaria M. Ruggeri

    2010-01-01

    Full Text Available A 63-year-old woman presented to the Orthopedic Unit of our hospital complaining of right hip pain of 6 months'duration associated with a worsening limp. Her past medical history included chronic renal insufficiency. Physical examination revealed deep pain in the iliac region and severe restriction of the right hip's articular function in the maximum degrees of range of motion. X-rays and CT scan detected an osteolytic and expansive lesion of the right supra-acetabular region with structural reabsorption of the right iliac wing. 99mTc-MDP whole-body bone scan showed an abnormal uptake in the right iliac region. Bone biopsy revealed an osteolytic lesion with multinucleated giant cells, indicating a brown tumor. Serum intact PTH was elevated (1020 pg/ml; normal values, 12 62 pg/ml, but her serum calcium was normal (total = 9.4 mg/dl, nv 8.5–10.5; ionized = 5.0 mg/dl, nv 4.2–5.4 due to the coexistence of chronic renal failure. 99mTc-MIBI scintigraphy revealed a single focus of sestamibi accumulation in the left retrosternal location, which turned out to be an intrathoracic parathyroid adenoma at surgical exploration. After surgical removal of the parathyroid adenoma, PTH levels decreased to 212 pg/ml. Three months after parathyroidectomy, the imaging studies showed complete recovery of the osteolytic lesion, thus avoiding any orthopedic surgery. This case is noteworthy because (1 primary hyperparathyroidism was not suspected due to the normocalcemia, likely attributable to the coexistence of chronic renal failure; and (2 it was associated with a brown tumor of unusual location (right supra-acetabular region.

  9. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    Science.gov (United States)

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Accessing 3D Location of Standing Pelvis: Relative Position of Sacral Plateau and Acetabular Cavities versus Pelvis

    International Nuclear Information System (INIS)

    Berthonnaud, E.; Hilmi, R.; Berthonnaud, E.; Berthonnaud, E.; Dimnet, J.

    2012-01-01

    The goal of this paper is to access to pelvis position and morphology in standing posture and to determine the relative locations of their articular surfaces. This is obtained from coupling bi planar radiography and bone modeling. The technique involves different successive steps. Punctual landmarks are first reconstructed, in space, from their projected images, identified on two orthogonal standing X-rays. Geometric models, of global pelvis and articular surfaces, are determined from punctual landmarks. The global pelvis is represented as a triangle of summits: the two femoral head centers and the sacral plateau center. The two acetabular cavities are modeled as hemispheres. The anterior sacral plateau edge is represented by an hemi-ellipsis. The modeled articular surfaces are projected on each X-ray. Their optimal location is obtained when the projected contours of their models best fit real outlines identified from landmark images. Linear and angular parameters characterizing the position of global pelvis and articular surfaces are calculated from the corresponding sets of axis. Relative positions of sacral plateau, and acetabular cavities, are then calculated. Two hundred standing pelvis, of subjects and scoliotic patients, have been studied. Examples are presented. They focus upon pelvis orientations, relative positions of articular surfaces, and pelvis asymmetries.

  11. UV curing silicon-containing epoxy resin and its glass cloth reinforced composites

    International Nuclear Information System (INIS)

    Yang Guang; Tang Zhuo; Huang Pengcheng

    2007-01-01

    A UV-curable cationic silicon-containing epoxy resin formulation was developed. The gel conversion of the cured resin after 10-min UV irradiation reached 80% in the presence of 5% diaryliodonium salt photoinitiator and 5.5% polyol chain transfer agent by cationic ring-opening polymerization. The glass cloth-reinforced composites were fabricated with the silicon-containing epoxy resin using the wet lay-up technique and UV irradiation. The mechanical properties of the composites were evaluated. Compared with glass cloth reinforced bisphenol A epoxy resin matrix composites, the silicon-containing epoxy resin matrix composites possessed higher tensile strength and interlayer shear strength which was 158.5MPa and 9.9MPa respectively while other mechanical properties such as flexural property and tensile modulus were similar. (authors)

  12. Behavior of reinforced concrete beams reinforced with GFRP bars

    Directory of Open Access Journals (Sweden)

    D. H. Tavares

    Full Text Available The use of fiber reinforced polymer (FRP bars is one of the alternatives presented in recent studies to prevent the drawbacks related to the steel reinforcement in specific reinforced concrete members. In this work, six reinforced concrete beams were submitted to four point bending tests. One beam was reinforced with CA-50 steel bars and five with glass fiber reinforced polymer (GFRP bars. The tests were carried out in the Department of Structural Engineering in São Carlos Engineering School, São Paulo University. The objective of the test program was to compare strength, reinforcement deformation, displacement, and some anchorage aspects between the GFRP-reinforced concrete beams and the steel-reinforced concrete beam. The results show that, even though four GFRP-reinforced concrete beams were designed with the same internal tension force as that with steel reinforcement, their capacity was lower than that of the steel-reinforced beam. The results also show that similar flexural capacity can be achieved for the steel- and for the GFRP-reinforced concrete beams by controlling the stiffness (reinforcement modulus of elasticity multiplied by the bar cross-sectional area - EA and the tension force of the GFRP bars.

  13. Three-dimensional magnetic resonance imaging analysis of hip morphology in the assessment of femoral acetabular impingement

    International Nuclear Information System (INIS)

    Kavanagh, E.C.; Read, P.; Carty, F.; Zoga, A.C.; Parvizi, J.; Morrison, W.B.

    2011-01-01

    Aim: To determine a possible association between femoral-acetabular impingement (FAI) volume and the development of labral tear using a three-dimensional (3D) model reconstruction of the acetabulum and the femoral head. Materials and methods: Magnetic resonance arthrography images of the hip in 42 patients with pain and suspected labral tear were acquired using a 1.5 T MRI machine. Using 3D analysis software, outlines of the acetabular cup and femoral head were drawn and 3D reconstruction obtained. To control for differences in patient size, ratios of acetabulum : femoral head volume (AFV) and acetabulum : femoral head surface area (AFA) were used for analysis. The association between volume of acetabulum : femoral head and FAI was investigated using ANOVA analysis. Results: There were 19 men and 23 women with a mean age of 39 years (range 18-78 years). The average AFV was 0.64 (range 0.37-1.05, SD 0.16) and AFA was 0.73 (range 0.36-1.26, SD 0.23). Herniation pit was significantly associated with a small AFV. Conclusion: Femoral neck herniation pits are associated with a low AFV. Gross volume and surface area ratios do not appear to correlate with labral tears or cartilage loss. This technique will enable more advanced analysis of morphological variations associated with FAI.

  14. Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components.

    Science.gov (United States)

    Kurtz, S M; Siskey, R; Reitman, M

    2010-05-01

    The objectives of this study were three-fold: (1) to determine the applicability of the small punch test to characterize Bionate 80A polycarbonate urethane (PCU) acetabular implants; (2) to evaluate the susceptibility of PCU acetabular implants to exhibit degradation of mechanical behavior following gamma irradiation in air and accelerated aging; and (3) to compare the oxidation of gamma-air sterilized PCU following accelerated aging and 5 years of natural shelf aging. In addition to attenuated total reflectance-Fourier transform infrared spectroscopy, we also adapted a miniature specimen mechanical test, the small punch test, for the deformable PCU cups. Accelerated aging was performed using ASTM F2003, a standard test that represents a severe oxidative challenge. The results of this study suggest that the small punch test is sufficiently sensitive and reproducible to discriminate slight differences in the large-deformation mechanical behavior of Bionate 80A following accelerated aging. The gamma-air sterilized PCU had a reduction of 9% in ultimate load after aging. Five years of shelf aging had little effect on the mechanical properties of the PCU. Overall, our findings suggest that the Bionate 80A material has greater oxidative stability than ultra-high molecular weight polyethylene following gamma irradiation in air and exposure to a severe oxidative challenge. (c) 2010 Wiley Periodicals, Inc.

  15. Utility of radiation in the prevention of heterotopic ossification following repair of traumatic acetabular fracture

    International Nuclear Information System (INIS)

    Haas, Michael L.; Kennedy, Andrew S.; Copeland, Carol C.; Ames, John W.; Scarboro, Mark; Slawson, Robert G.

    1999-01-01

    Purpose: Heterotopic ossification (HO) is a common problem following surgical repair of traumatic acetabular fracture (TAF), potentially causing severe pain and decreased range of motion. This report analyzes the role of radiation therapy for prevention of HO in TAF. Methods and Materials: The charts of all patients who received RT to the hip following TAF repair between July 1988 and January 1998 were reviewed. Sixty-six patients were identified. RT was given in 5 fractions of 2 Gy in 45 patients, 1 fraction of 8 Gy in 17 patients, and other doses in 4 patients. Treatment fields encompassed peri acetabular tissues at highest risk for HO. Time to RT was ≤ 24 hours for 46 patients. Results: Radiographic follow-up at least 6 months following RT was available in 47/66 (71%) patients to permit Brooker classification, revealing 6 cases (13%) of Grade III HO, compared to historical incidence in this population of 50%. No Grade IV HO was found. Mean follow-up was 18 months. Four of the Grade III patients had received 10 Gy/5 fractions, and 2 received 8 Gy/1 fraction. Postoperative wound infection occurred in 6 patients, and osteonecrosis of the femoral head was found in 13. Conclusions: RT following surgical repair of TAF provides effective prophylaxis against formation of clinically significant HO. We recommend a single fraction of 7-8 Gy within 24 hours of surgery to prevent HO formation and minimize patient discomfort

  16. LABORATORY EVALUATION ON PERFORMANCE OF GLASS FIBER REINFORCED PLASTIC MORTAR PIPE CULVERTS

    Directory of Open Access Journals (Sweden)

    Huawang Shi

    2018-04-01

    Full Text Available This paper investigated the performance and behaviour of glass fiber reinforced plastic mortar (FRPM pipes under different loading conditions. FRPM pipes with inner diameter of 1500 mm were prefabricated in factory. Mechanics performance testing (ring and axial compressive strength and elastic modulus, stiffness and fatigue test were carried out in laboratory. Ring stiffness test provided pipe stiffness (PS which is a function of geometry and material type of pipe through parallel plate loading test (PPLT. The fatigue test and micro-structure measure method were used to evaluate the durability effects of FRPM under repeated compression load. Results indicated that FRPM pipes had better mechanic performances as the road culverts under soils. It may be helpful for the design and construction of FRPM culverts.

  17. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    Science.gov (United States)

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Ring Theory

    CERN Document Server

    Jara, Pascual; Torrecillas, Blas

    1988-01-01

    The papers in this proceedings volume are selected research papers in different areas of ring theory, including graded rings, differential operator rings, K-theory of noetherian rings, torsion theory, regular rings, cohomology of algebras, local cohomology of noncommutative rings. The book will be important for mathematicians active in research in ring theory.

  19. Braided reinforced composite rods for the internal reinforcement of concrete

    Science.gov (United States)

    Gonilho Pereira, C.; Fangueiro, R.; Jalali, S.; Araujo, M.; Marques, P.

    2008-05-01

    This paper reports on the development of braided reinforced composite rods as a substitute for the steel reinforcement in concrete. The research work aims at understanding the mechanical behaviour of core-reinforced braided fabrics and braided reinforced composite rods, namely concerning the influence of the braiding angle, the type of core reinforcement fibre, and preloading and postloading conditions. The core-reinforced braided fabrics were made from polyester fibres for producing braided structures, and E-glass, carbon, HT polyethylene, and sisal fibres were used for the core reinforcement. The braided reinforced composite rods were obtained by impregnating the core-reinforced braided fabric with a vinyl ester resin. The preloading of the core-reinforced braided fabrics and the postloading of the braided reinforced composite rods were performed in three and two stages, respectively. The results of tensile tests carried out on different samples of core-reinforced braided fabrics are presented and discussed. The tensile and bending properties of the braided reinforced composite rods have been evaluated, and the results obtained are presented, discussed, and compared with those of conventional materials, such as steel.

  20. Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Saverio Affatato

    2017-03-01

    Full Text Available Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations.

  1. Computerized tomography in evaluation of decreased acetabular and femoral anteversion

    International Nuclear Information System (INIS)

    Toennis, D.; Skamel, H.J.

    2003-01-01

    Computerized tomography has received a new importance. It has been shown that decreased anteversion of femur and acetabulum, when both have decreased angles, are causing pain and osteoarthritis of the hip joint. Operative treatment should be performed before osteoarthritis develops. Exact measurements therefore are necessary. The investigation should be performed in prone position to have the pelvis lying in a defined and normal position. Femoral torsion is measured between the transverse axis of the knee and the femoral neck. The transverse axis for measurement of the femoral anteversion is defined by a rectangular line to the sagittal plane. For evaluation of the femoral anteversion in total the angle of the condyles has to be added to the femoral neck angle when the knee is found in internal rotation. Acetabular anteversion should be measured at the level where the femoral head is still in full contact and congruence with the anterior margin of the acetabulum. (orig.) [de

  2. Flexural reinforced concrete member with FRP reinforcement

    OpenAIRE

    Putzolu, Mariana

    2017-01-01

    One of the most problematic point in construction is the durability of the concrete especially related to corrosion of the steel reinforcement. Due to this problem the construction sector, introduced the use of Fiber Reinforced Polymer, the main fibers used in construction are Glass, Carbon and Aramid. In this study, the author aim to analyse the flexural behaviour of concrete beams reinforced with FRP. This aim is achieved by the analysis of specimens reinforced with GFRP bars, with theoreti...

  3. Report of the eRHIC Ring-Ring Working Group

    Energy Technology Data Exchange (ETDEWEB)

    Aschenauer, E. C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Berg, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brennan, M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fedotov, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Litvinenko, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Montag, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Palmer, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Parker, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Peggs, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ranjbar, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tepikian, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Trbojevic, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Willeke, F. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-10-13

    This report evaluates the ring-ring option for eRHIC as a lower risk alternative to the linac-ring option. The reduced risk goes along with a reduced initial luminosity performance. However, a luminosity upgrade path is kept open. This upgrade path consists of two branches, with the ultimate upgrade being either a ring-ring or a linac-ring scheme. The linac-ring upgrade could be almost identical to the proposed linac-ring scheme, which is based on an ERL in the RHIC tunnel. This linac-ring version has been studied in great detail over the past ten years, and its significant risks are known. On the other hand, no detailed work on an ultimate performance ring-ring scenario has been performed yet, other than the development of a consistent parameter set. Pursuing the ring-ring upgrade path introduces high risks and requires significant design work that is beyond the scope of this report.

  4. Conventional versus virtual radiographs of the injured pelvis and acetabulum

    Energy Technology Data Exchange (ETDEWEB)

    Bishop, Julius A.; Rao, Allison J.; Pouliot, Michael A.; Bellino, Michael [Stanford University School of Medicine, Department of Orthopaedic Surgery, Stanford, CA (United States); Beaulieu, Christopher [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2015-09-15

    Evaluation of the fractured pelvis or acetabulum requires both standard radiographic evaluation as well as computed tomography (CT) imaging. The standard anterior-posterior (AP), Judet, and inlet and outlet views can now be simulated using data acquired during CT, decreasing patient discomfort, radiation exposure, and cost to the healthcare system. The purpose of this study is to compare the image quality of conventional radiographic views of the traumatized pelvis to virtual radiographs created from pelvic CT scans. Five patients with acetabular fractures and ten patients with pelvic ring injuries were identified using the orthopedic trauma database at our institution. These fractures were evaluated with both conventional radiographs as well as virtual radiographs generated from a CT scan. A web-based survey was created to query overall image quality and visibility of relevant anatomic structures. This survey was then administered to members of the Orthopaedic Trauma Association (OTA). Ninety-seven surgeons completed the acetabular fracture survey and 87 completed the pelvic fracture survey. Overall image quality was judged to be statistically superior for the virtual as compared to conventional images for acetabular fractures (3.15 vs. 2.98, p = 0.02), as well as pelvic ring injuries (2.21 vs. 1.45, p = 0.0001). Visibility ratings for each anatomic landmark were statistically superior with virtual images as well. Virtual radiographs of pelvic and acetabular fractures offer superior image quality, improved comfort, decreased radiation exposure, and a more cost-effective alternative to conventional radiographs. (orig.)

  5. The Use of a 3D Printer in Pre-operative Planning for a Patient Requiring Acetabular Reconstructive Surgery.

    Science.gov (United States)

    Duncan, James M; Nahas, Samuel; Akhtar, Kashif; Daurka, Jasvinder

    2015-01-01

    Surgical management of acetabular fractures is often highly complex, and a successful outcome depends upon an appreciation of the fracture pattern and the most appropriate approach to reduce and hold it. Currently, computed tomography (CT) images are used in conjunction with plain x-rays to identify the main fracture components and their spatial relationship to one another, and as such surgeons still have to make decisions based upon their ability to visualise the fracture from the images available. 3D printers have now become widely available and inexpensive, and can be used to rapidly produce life-size models based on CT scans of an individual patient. The availability of patient specific, accurate and detailed models of complex acetabular fractures can aid planning of surgical management on a patient specific basis. This report describes the use of a 3D printer to create a life-size model reconstruction of the pelvis of a 48 year old male patient who sustained a left sided associated both column acetabular fracture following a motorbike accident in the Sahara Desert. The model allowed visualisation of the multiple fracture fragments and their relative displacements. The tactile feedback allowed assessment of the different fracture fragments. The relative displacement of the quadrilateral plate and posterior column fragments could be assessed and the surgeon felt that these would be amenable to reduction from an ilioinguinal approach. An anatomic reduction was achieved and was held with the application of a pelvic brim plate with 2 screws lagging the posterior column/quadrilateral plate fragment. There are previous examples of 3D models being used in orthopaedic surgery through the use of rapid prototyping, however this method is usually expensive and time consuming. Advances in 3D printer technology offer surgeons a number of advantages when treating these complex fractures. With the ever-increasing economy, ease of use and speed of additive processing, the

  6. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

    Science.gov (United States)

    Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H

    2017-03-01

    To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.

  7. Study on reinforced concrete beams with helical transverse reinforcement

    Science.gov (United States)

    Kaarthik Krishna, N.; Sandeep, S.; Mini, K. M.

    2018-02-01

    In a Reinforced Concrete (R.C) structure, major reinforcement is used for taking up tensile stresses acting on the structure due to applied loading. The present paper reports the behavior of reinforced concrete beams with helical reinforcement (transverse reinforcement) subjected to monotonous loading by 3-point flexure test. The results were compared with identically similar reinforced concrete beams with rectangular stirrups. During the test crack evolution, load carrying capacity and deflection of the beams were monitored, analyzed and compared. Test results indicate that the use of helical reinforcement provides enhanced load carrying capacity and a lower deflection proving to be more ductile, clearly indicating the advantage in carrying horizontal loads. An analysis was also carried out using ANSYS software in order to compare the test results of both the beams.

  8. ASSOCIATIVE RINGS SOLVED AS LIE RINGS

    Directory of Open Access Journals (Sweden)

    M. B. Smirnov

    2011-01-01

    Full Text Available The paper has proved that an associative ring which is solvable of a n- class as a Lie ring has a nilpotent ideal of the nilpotent class not more than 3×10n–2  and a corresponding quotient ring satisfies an identity [[x1, x2, [x3, x4

  9. REINFORCED COMPOSITE PANEL

    DEFF Research Database (Denmark)

    2003-01-01

    A composite panel having front and back faces, the panel comprising facing reinforcement, backing reinforcement and matrix material binding to the facing and backing reinforcements, the facing and backing reinforcements each independently comprising one or more reinforcing sheets, the facing rein...... by matrix material, the facing and backing reinforcements being interconnected to resist out-of-plane relative movement. The reinforced composite panel is useful as a barrier element for shielding structures, equipment and personnel from blast and/or ballistic impact damage....

  10. Outcome of periacetabular osteotomy for the management of acetabular dysplasia: experience in an academic centre.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2011-02-01

    Periacetabular osteotomy (PAO) is a very effective reconstructive procedure for treatment of acetabular dysplasia. An orthopaedic paediatric surgeon and a reconstructive hip arthroplasty surgeon performed this procedure together in the early phase of their learning curve and then performed it individually. The early clinical and radiographic results of 85 consecutive PAOs performed in this academic orthopaedic unit were reviewed. The mean Merle-d\\'Aubigné score increased from 12.4 preoperatively to 16 at follow-up. Pre-operatively 73 hips were anteverted and 12 were neutral or retroverted. The mean angle of Wiberg improved from 5 degrees to 21 degrees (p < 0.0001) in anteverted hips, and from 9 degrees to 30 degrees in neutral or retroverted hips. The mean angle of Lequesne and de Sèze improved from 6 degrees to 35 degrees (p < 0.0001) in anteverted hips, and in neutral or retroverted hips from 9 degrees to 30 degrees (p < 0.0001). The acetabular index improved from 26 degrees to 8 degrees (p < 0.0001) in anteverted hips, and from 21 degrees to 7 degrees (p < 0.0001) in neutral or retroverted hips. Over the 7 year period the blood loss and operative time improved from 2000 ml to 900 ml and 4 hours to 2 hours respectively. Four hips (four patients) required conversion to total hip replacement. The radiographic correction and improved clinical scores are similar to those in previous studies. This study shows a survival rate of 94% at 58 months following periacetabular osteotomy. The learning curve and the early results of this procedure performed in our academic unit are encouraging.

  11. Internal Fixation of Complicated Acetabular Fractures Directed by Preoperative Surgery with 3D Printing Models.

    Science.gov (United States)

    Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng

    2017-05-01

    The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  12. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

    Science.gov (United States)

    Craiovan, B; Weber, M; Worlicek, M; Schneider, M; Springorum, H R; Zeman, F; Grifka, J; Renkawitz, T

    2016-06-01

    The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane. The mean difference between the radiographic and the 3D-CT measurements was - 1.4° ± 3.9° for inclination and 0.8°± 7.9° for anteversion with excellent correlation for inclination (r = 0.81, p cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future. • Measuring acetabular cup orientation on anteroposterior radiographs of the hip after THA is a helpful procedure in everyday clinical practice as a first-line imaging modality• CT remains the golden standard to accurately determine acetabular cup position.• Future measuring on radiographs for cup orientation after THA should account for integration of the pelvic tilt in order to maximize the measurement accuracy. Citation Format: • Craiovan B, Weber M, Worlicek M et al. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?. Fortschr Röntgenstr 2016; 188: 574 - 581. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Influence of pelvic position on radiographic measurements of the prosthetic acetabular component

    International Nuclear Information System (INIS)

    Thoren, B.; Sahlstedt, B.; Uppsala Univ.

    1990-01-01

    A change in the position of a prosthetic acetabular component between two different radiographic examinations indicates loosening, and may be observed as tilting or migration of the socket. To determine the apparent changes in socket position caused by improper positioning of the pelvis, a full-scale model of a pelvis with attached prosthetic sockets was examined radiographically in different positions. The projected alignment of the Charnley socket indicator wire against the inter-tuberosity line was markedly influenced by the positioning of the pelvis. An alternative way of measuring the alignment is to use the long axis of the projected ellipse of the outer circumferential groove in the socket polyethylene. The thus defined socket alignment was not influenced by the positioning of the pelvis within the investigated range. No apparent socket migration was recorded within the range of pelvic rotation and inclination studied. (orig.)

  14. Mapping Ring Particle Cooling across Saturn's Rings with Cassini CIRS

    Science.gov (United States)

    Brooks, Shawn M.; Spilker, L. J.; Edgington, S. G.; Pilorz, S. H.; Deau, E.

    2010-10-01

    Previous studies have shown that the rings' thermal inertia, a measure of their response to changes in the thermal environment, varies from ring to ring. Thermal inertia can provide insight into the physical structure of Saturn's ring particles and their regoliths. Low thermal inertia and quick temperature responses are suggestive of ring particles that have more porous or fluffy regoliths or that are riddled with cracks. Solid, coherent particles can be expected to have higher thermal inertias (Ferrari et al. 2005). Cassini's Composite Infrared Spectrometer has recorded millions of spectra of Saturn's rings since its arrival at Saturn in 2004 (personal communication, M. Segura). CIRS records far infrared radiation between 10 and 600 cm-1 (16.7 and 1000 µm) at focal plane 1 (FP1), which has a field of view of 3.9 mrad. Thermal emission from Saturn's rings peaks in this wavelength range. FP1 spectra can be used to infer ring temperatures. By tracking how ring temperatures vary, we can determine the thermal inertia of the rings. In this work we focus on CIRS observations of the shadowed portion of Saturn's rings. The thermal budget of the rings is dominated by the solar radiation absorbed by its constituent particles. When ring particles enter Saturn's shadow this source of energy is abruptly cut off. As a result, ring particles cool as they traverse Saturn's shadow. From these shadow observations we can create cooling curves at specific locations across the rings. We will show that the rings' cooling curves and thus their thermal inertia vary not only from ring to ring, but by location within the individual rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2010 California Institute of Technology. Government sponsorship acknowledged.

  15. Effect of centre-edge angle on clinical and quality of life outcomes after arthroscopic acetabular labral debridement.

    Science.gov (United States)

    Wu, Ziying; Chen, Shiyi; Li, Yunxia; Li, Hong; Chen, Jiwu

    2016-07-01

    The aim of this study was to compare clinical and quality of life outcomes following arthroscopic acetabular labral debridement between patients with different centre-edge (CE) angle. A total of 79 patients who underwent hip labral debridement were enrolled in this study. Radiographic measurements of CE angle were collected, and patients were assigned into a normal group (25°  0.05). Additionally, there was a greater improvement in clinical scores post-operatively in the normal group compared with the dysplasia group (P 25° compared with patients with CE angle < 20°.

  16. Effectiveness of Fiber Reinforcement on the Mechanical Properties and Shrinkage Cracking of Recycled Fine Aggregate Concrete

    Science.gov (United States)

    Nam, Jeongsoo; Kim, Gyuyong; Yoo, Jaechul; Choe, Gyeongcheol; Kim, Hongseop; Choi, Hyeonggil; Kim, Youngduck

    2016-01-01

    This paper presents an experimental study conducted to investigate the effect of fiber reinforcement on the mechanical properties and shrinkage cracking of recycled fine aggregate concrete (RFAC) with two types of fiber—polyvinyl alcohol (PVA) and nylon. A small fiber volume fraction, such as 0.05% or 0.1%, in RFAC with polyvinyl alcohol or nylon fibers was used for optimum efficiency in minimum quantity. Additionally, to make a comparative evaluation of the mechanical properties and shrinkage cracking, we examined natural fine aggregate concrete as well. The test results revealed that the addition of fibers and fine aggregates plays an important role in improving the mechanical performance of the investigated concrete specimens as well as controlling their cracking behavior. The mechanical properties such as compressive strength, splitting tensile strength, and flexural strength of fiber-reinforced RFAC were slightly better than those of non-fiber-reinforced RFAC. The shrinkage cracking behavior was examined using plat-ring-type and slab-type tests. The fiber-reinforced RFAC showed a greater reduction in the surface cracks than non-fiber-reinforced concrete. The addition of fibers at a small volume fraction in RFAC is more effective for drying shrinkage cracks than for improving mechanical performance. PMID:28773256

  17. Effectiveness of Fiber Reinforcement on the Mechanical Properties and Shrinkage Cracking of Recycled Fine Aggregate Concrete.

    Science.gov (United States)

    Nam, Jeongsoo; Kim, Gyuyong; Yoo, Jaechul; Choe, Gyeongcheol; Kim, Hongseop; Choi, Hyeonggil; Kim, Youngduck

    2016-02-26

    This paper presents an experimental study conducted to investigate the effect of fiber reinforcement on the mechanical properties and shrinkage cracking of recycled fine aggregate concrete (RFAC) with two types of fiber-polyvinyl alcohol (PVA) and nylon. A small fiber volume fraction, such as 0.05% or 0.1%, in RFAC with polyvinyl alcohol or nylon fibers was used for optimum efficiency in minimum quantity. Additionally, to make a comparative evaluation of the mechanical properties and shrinkage cracking, we examined natural fine aggregate concrete as well. The test results revealed that the addition of fibers and fine aggregates plays an important role in improving the mechanical performance of the investigated concrete specimens as well as controlling their cracking behavior. The mechanical properties such as compressive strength, splitting tensile strength, and flexural strength of fiber-reinforced RFAC were slightly better than those of non-fiber-reinforced RFAC. The shrinkage cracking behavior was examined using plat-ring-type and slab-type tests. The fiber-reinforced RFAC showed a greater reduction in the surface cracks than non-fiber-reinforced concrete. The addition of fibers at a small volume fraction in RFAC is more effective for drying shrinkage cracks than for improving mechanical performance.

  18. A thermal active restrained shrinkage ring test to study the early age concrete behaviour of massive structures

    International Nuclear Information System (INIS)

    Briffaut, M.; Benboudjema, F.; Torrenti, J.M.; Nahas, G.

    2011-01-01

    In massive concrete structures, cracking may occur during hardening, especially if autogenous and thermal strains are restrained. The concrete permeability due to this cracking may rise significantly and thus increase leakage (in tank, nuclear containment...) and reduce the durability. The restrained shrinkage ring test is used to study the early age concrete behaviour (delayed strains evolution and cracking). This test shows, at 20 o C and without drying, for a concrete mix which is representative of a French nuclear power plant containment vessel (w/c ratio equal to 0.57), that the amplitude of autogenous shrinkage (about 40 μm/m for the studied concrete mix) is not high enough to cause cracking. Indeed, in this configuration, thermal shrinkage is not significant, whereas this is a major concern for massive structures. Therefore, an active test has been developed to study cracking due to restrained thermal shrinkage. This test is an evolution of the classical restrained shrinkage ring test. It allows to take into account both autogenous and thermal shrinkages. Its principle is to create the thermal strain effects by increasing the temperature of the brass ring (by a fluid circulation) in order to expand it. With this test, the early age cracking due to restrained shrinkage, the influence of reinforcement and construction joints have been experimentally studied. It shows that, as expected, reinforcement leads to an increase of the number of cracks but a decrease of crack widths. Moreover, cracking occurs preferentially at the construction joint.

  19. Reinforcement Magnitude: An Evaluation of Preference and Reinforcer Efficacy

    OpenAIRE

    Trosclair-Lasserre, Nicole M; Lerman, Dorothea C; Call, Nathan A; Addison, Laura R; Kodak, Tiffany

    2008-01-01

    Consideration of reinforcer magnitude may be important for maximizing the efficacy of treatment for problem behavior. Nonetheless, relatively little is known about children's preferences for different magnitudes of social reinforcement or the extent to which preference is related to differences in reinforcer efficacy. The purpose of the current study was to evaluate the relations among reinforcer magnitude, preference, and efficacy by drawing on the procedures and results of basic experimenta...

  20. Open reduction and internal fixation of osteoporotic acetabular fractures through the ilio-inguinal approach: use of buttress plates to control medial displacement of the quadrilateral surface.

    Science.gov (United States)

    Peter, Robin E

    2015-01-01

    The number of acetabular fractures in the geriatric population requiring open reduction and internal fixation is increasing. Fractures with medial or anterior displacement are the most frequent types, and via the ilio-inguinal approach buttress plates have proved helpful to maintain the quadrilateral surface or medial acetabular wall. Seven to ten hole 3.5 mm reconstruction plates may be used as buttress plates, placed underneath the usual pelvic brim plate. This retrospective study presents our results with this technique in 13 patients at a minimum follow-up of 12 months (average, 31 months). 85% of the patients had a good result. The early onset of post-traumatic osteoarthritis necessitated total hip arthroplasty in two patients (15%) at 12 and 18 months follow-up, respectively. This treatment option should be considered in the surgeon's armamentarium when fixing these challenging cases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Reinforced sulphur concrete

    NARCIS (Netherlands)

    2014-01-01

    Reinforced sulphur concrete wherein one or more metal reinforcing members are in contact with sulphur concrete is disclosed. The reinforced sulphur concrete comprises an adhesion promoter that enhances the interaction between the sulphur and the one or more metal reinforcing members.

  2. Hip flexor muscle size, strength and recruitment pattern in patients with acetabular labral tears compared to healthy controls.

    Science.gov (United States)

    Mendis, M Dilani; Wilson, Stephen J; Hayes, David A; Watts, Mark C; Hides, Julie A

    2014-10-01

    Acetabular labral tears are a source of hip pain and are considered to be a precursor to hip osteoarthritis. Hip flexor muscles contribute to hip joint stability and function but it is unknown if their size and function is altered in the presence of labral pathology. This study aimed to investigate hip flexor muscle size, strength and recruitment pattern in patients with hip labral pathology compared to control subjects. 12 subjects diagnosed with an unilateral acetabular labral tear were compared to 12 control subjects matched for age and gender. All subjects underwent magnetic resonance imaging (MRI) of their lumbo-pelvic region. Average muscle cross-sectional area (CSA) of the iliacus, psoas, iliopsoas, sartorius, tensor fascia latae and rectus femoris muscles were measured. Hip flexion strength was measured by an externally fixed dynamometer. Individual muscle recruitment pattern during a resisted hip flexion exercise task was measured by muscle functional MRI. Hip flexor muscle strength was found to be decreased in patients with labral pathology compared to control subjects (p muscle size (all p > 0.17) and recruitment pattern (all p > 0.53). Decreased hip flexor muscle strength may affect physical function in patients with hip labral pathology by contributing to altered gait patterns and functional tasks. Clinical rehabilitation of these patients may need to include strengthening exercises for the hip flexor muscles. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Magnetic resonance arthrography and the prevalence of acetabular labral tears in patients 50 years of age and older

    International Nuclear Information System (INIS)

    Jayakar, Rohit; Merz, Alexa; Wang, Dean; Hame, Sharon L.; Plotkin, Benjamin; Seeger, Leanne

    2016-01-01

    Arthroscopy for acetabular labral tears has minimal impact on pain and function in older patients, especially in the setting of concomitant osteoarthritis. Still, many physicians seek this diagnosis with MR arthrography. Our purpose is to assess the frequency of acetabular labral tears in older patients with hip pain and correlate likelihood of labral pathology with severity of osteoarthritis as visualized on conventional radiograph. From 2004 to 2013, 208 hip MRI arthrograms and corresponding radiographs on patients aged 50 years and older were identified. Age, gender, grade and location of labral tear, alpha angle, Toennis grade, and joint space width were documented. Labral tears and alpha angle were identified and measured on MR arthrogram. Toennis grade and joint space width were measured on radiographs. On MR arthrography, true labral tearing was identified in 73 % of patients. There was some degree of labral pathology in 93.3 % of patients, and this increased to 100 % in patients with moderate to severe osteoarthritis, as defined by Toennis grade 2-3 or joint space width ≤ 2 mm. There were no statistically significant correlations between labral tear grade and Toennis grade or joint space width. Given the high frequency of labral pathology and the questionable efficacy of arthroscopic surgical intervention in older patients, MR arthrography should be primarily for those with minimal arthritis on radiograph and potential to benefit from surgery. If further imaging beyond radiographs is necessary in these patients, standard MRI may be a more appropriate imaging tool. (orig.)

  4. Percutaneous acetabuloplasty for metastatic acetabular lesions

    Directory of Open Access Journals (Sweden)

    Logroscino Giandomenico

    2008-05-01

    Full Text Available Abstract Background Osteolytic metastases around the acetabulum are frequent in tumour patients, and may cause intense and drug-resistant pain of the hip. These lesions also cause structural weakening of the pelvis, limping, and poor quality of life. Percutaneous acetabuloplasty is a mini-invasive procedure for the management of metastatic lesions due to carcinoma of the acetabulum performed in patients who cannot tolerate major surgery, or in patients towards whom radiotherapy had already proved ineffective. Methods We report a retrospective study in 25 such patients (30 acetabuli who were evaluated before and after percutaneous acetabuloplasty, with regard to pain, mobility of the hip joint, use of analgesics, by means of evaluation forms: Visual Analog Scale, Harris Hip Score, Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC, Eastern Cooperative Oncology Group (ECOG. The results obtained were analysed using the χ2 Test and Fisher's exact test. Significance was sent at P Results Marked clinical improvement was observed in all patients during the first six post-operative months, with gradual a worsening thereafter from deterioration of their general condition. Complete pain relief was achieved in 15 of our 25 (59% of patients, and pain reduction was achieved in the remaining 10 (41% patients. The mean duration of pain relief was 7.3 months. Pain recurred in three patients (12% between 2 weeks to 3 months. No major complications occurred. There was transient local pain in most cases, and 2 cases of venous injection of cement without clinical consequences. Conclusion Percutaneous acetabuloplasty is effective in improving the quality of life of patients with osteolytic bone tumours, even though the improvement is observed during the first 6 months only. It can be an effective aid to chemo- and radiotherapy in the management of acetabular metastases.

  5. Evaluation of articular cartilage following rotational acetabular osteotomy for hip dysplasia using T2 mapping MRI.

    Science.gov (United States)

    Shoji, Takeshi; Yamasaki, Takuma; Izumi, Soutaro; Sawa, Mikiya; Akiyama, Yuji; Yasunaga, Yuji; Adachi, Nobuo

    2018-04-27

    Rotational acetabular osteotomy (RAO) is one of the surgical treatments for acetabular dysplasia, and satisfactory results have been reported. We evaluated the postoperative changes of articular cartilage and whether the pre-operative condition of the articular cartilage influences the clinical results using T2 mapping MRI. We reviewed 31 hips with early stage osteoarthritis in 31 patients (mean age, 39.6 years), including three men and 28 women who underwent RAO for hip dysplasia. Clinical evaluations including Japanese Orthopedic Association (JOA) score and Japanese Orthopedic Association Hip Disease Evaluation Questionnaire (JHEQ), and radiographical evaluations on X-ray were performed. Longitudinal qualitative assessment of articular cartilage was also performed using 3.0-T MRI with T2 mapping technique preoperatively, 6 months, and at 1 and 2 years postoperatively. There was no case with progression of osteoarthritis. The mean JOA score improved from 70.1 to 93.4 points, the mean postoperative JHEQ score was 68.8 points, and radiographical data also improved postoperatively. We found that the T2 values of the cartilage at both femoral head and acetabulum increased at 6 months on coronal and sagittal views. However, they significantly decreased 1 and 2 years postoperatively. The T2 values of the center to anterolateral region of acetabulum negatively correlated with postoperative JHEQ score, particularly in pain score. This study suggests that biomechanical and anatomical changes could apparently cause decreased T2 values 1-2 years postoperatively compared with those preoperatively. Furthermore, preoperative T2 values of the acetabulum can be prognostic factors for the clinical results of RAO.

  6. The use of customized cages in revision total hip arthroplasty for Paprosky type III acetabular bone defects.

    Science.gov (United States)

    Mao, Yuanqing; Xu, Chen; Xu, Jiawei; Li, Huiwu; Liu, Fengxiang; Yu, Degang; Zhu, Zhenan

    2015-10-01

    Revision total hip arthroplasty (THA) is challenging if severe periacetabular bone loss is present. Here we describe a method that uses a customised cage to reconstruct an acetabulum with a massive bone defect. Designed with the aid of the rapid prototyping technique, a customised cage with a hook, crest and flange or braids was made, and then utilized to reconstruct severe compromised acetabulum in revision THA since 2001. Twenty-two patients (23 hips) were included in this study. The mean patient age at the time of surgery was 60.9 years (range, 38-80 years). Three hips had massive acetabular bone defects of Paprosky type IIIA and 20 of type IIIB. The Harris hip score was used to evaluate hip function. Radiographs were taken to evaluate loosening of the cage and resorption of allograft bone. The average follow up was 81.6 ± 24.9 months. The mean Harris hip score improved from 39.6 pre-operatively to 80.9 at the final follow-up. There were no instances of deep infection, severe venous thrombosis, and nerve palsy. One patient who had an intra-operative rupture of the superior acetabular artery was successfully treated using the haemostatic suturing technique. Two patients experienced dislocation at post-operative days four and six, respectively, and both were treated with closed reduction and skin traction for three weeks. The present study demonstrates that a customised cage may be a promising option for THA revision of severely compromised acetabula. Extended follow-up is necessary to evaluate the long-term performance of this approach.

  7. Black rings

    International Nuclear Information System (INIS)

    Emparan, Roberto; Reall, Harvey S

    2006-01-01

    A black ring is a five-dimensional black hole with an event horizon of topology S 1 x S 2 . We provide an introduction to the description of black rings in general relativity and string theory. Novel aspects of the presentation include a new approach to constructing black ring coordinates and a critical review of black ring microscopics. (topical review)

  8. Reinforcement Magnitude: An Evaluation of Preference and Reinforcer Efficacy

    Science.gov (United States)

    Trosclair-Lasserre, Nicole M.; Lerman, Dorothea C.; Call, Nathan A.; Addison, Laura R.; Kodak, Tiffany

    2008-01-01

    Consideration of reinforcer magnitude may be important for maximizing the efficacy of treatment for problem behavior. Nonetheless, relatively little is known about children's preferences for different magnitudes of social reinforcement or the extent to which preference is related to differences in reinforcer efficacy. The purpose of the current…

  9. Autoshaping Chicks with Heat Reinforcement: The Role of Stimulus-Reinforcer and Response-Reinforcer Relations

    Science.gov (United States)

    Wasserman, Edward A.; And Others

    1975-01-01

    The present series of experiments attempted to analyze more fully the contributions of stimulus-reinforcer and response-reinforcer relations to autoshaping within a single conditioning situation. (Author)

  10. To the problem of reinforced concrete reactor vessel design and calculation

    International Nuclear Information System (INIS)

    Kirillov, A.P.; Artem'ev, V.P.; Bogopol'skij, V.G.; Nikolaev, Yu.B.; Paushkin, A.G.

    1980-01-01

    Modern methods for calculating reactor vessels of prestressed reinforced concrete are analyzed. It is shown that during the stage of technical and economical substantiation of reactor vessel structure for determining its stressed-deformed state engineering methods of calculation must be used, in particular, fragmentation method, method of rings and plates, and during the stages of contract and detail designs - method of finite elements and dynamic relaxation method. It is concluded that when solving cyclic symmetrical problems as well as asymmetrical problems, calculational algorithms for axis-symmetrical distributions of stresses in the vessel with provision for elastic properties of structural material may be used

  11. Variations in Ring Particle Cooling across Saturn's Rings with Cassini CIRS

    Science.gov (United States)

    Brooks, S. M.; Spilker, L. J.; Pilorz, S.; Edgington, S. G.; Déau, E.; Altobelli, N.

    2010-12-01

    Cassini's Composite Infrared Spectrometer has recorded over two million of spectra of Saturn's rings in the far infrared since arriving at Saturn in 2004. CIRS records far infrared radiation between 10 and 600 cm-1 ( 16.7 and 1000 μ {m} ) at focal plane 1 (FP1), which has a field of view of 3.9 mrad. Thermal emission from Saturn’s rings peaks in this wavelength range. Ring temperatures can be inferred from FP1 data. By tracking how ring temperatures vary, we can determine the thermal inertia of the rings. Previous studies have shown that the rings' thermal inertia, a measure of their response to changes in the thermal environment, varies from ring to ring. Thermal inertia can provide insight into the physical structure of Saturn's ring particles and their regoliths. Low thermal inertia and rapidly changing temperatures are suggestive of ring particles that have more porous or fluffy regoliths or that are riddled with cracks. Solid particles can be expected to have higher thermal inertias. Ferrari et al. (2005) fit thermal inertia values of 5218 {Jm)-2 {K}-1 {s}-1/2 to their B ring data and 6412 {Jm)-2 {K}-1 {s}-1/2 to their C ring data. In this work we focus on CIRS observations of the shadowed portion of Saturn's rings. The rings’ thermal budget is dominated by its absorption of solar radiation. As a result, ring particles abruptly cool as they traverse Saturn's shadow. From these shadow observations we can create cooling curves at specific locations across the rings. We will show that the rings' cooling curves and thus their thermal inertia vary not only from ring to ring, but by location within the individual rings. This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under contract with NASA. Copyright 2010 California Institute of Technology. Government sponsorship acknowledged.

  12. Alternative loop rings

    CERN Document Server

    Goodaire, EG; Polcino Milies, C

    1996-01-01

    For the past ten years, alternative loop rings have intrigued mathematicians from a wide cross-section of modern algebra. As a consequence, the theory of alternative loop rings has grown tremendously. One of the main developments is the complete characterization of loops which have an alternative but not associative, loop ring. Furthermore, there is a very close relationship between the algebraic structures of loop rings and of group rings over 2-groups. Another major topic of research is the study of the unit loop of the integral loop ring. Here the interaction between loop rings and group ri

  13. Primitivity and weak distributivity in near rings and matrix near rings

    International Nuclear Information System (INIS)

    Abbasi, S.J.

    1993-08-01

    This paper shows the structure of matrix near ring constructed over a weakly distributive and primative near ring. It is proved that a weakly distributive primitive near ring is a ring and the matrix near rings constructed over it is also a bag. (author). 14 refs

  14. Genomic Signatures of Reinforcement

    Directory of Open Access Journals (Sweden)

    Austin G. Garner

    2018-04-01

    Full Text Available Reinforcement is the process by which selection against hybridization increases reproductive isolation between taxa. Much research has focused on demonstrating the existence of reinforcement, yet relatively little is known about the genetic basis of reinforcement or the evolutionary conditions under which reinforcement can occur. Inspired by reinforcement’s characteristic phenotypic pattern of reproductive trait divergence in sympatry but not in allopatry, we discuss whether reinforcement also leaves a distinct genomic pattern. First, we describe three patterns of genetic variation we expect as a consequence of reinforcement. Then, we discuss a set of alternative processes and complicating factors that may make the identification of reinforcement at the genomic level difficult. Finally, we consider how genomic analyses can be leveraged to inform if and to what extent reinforcement evolved in the face of gene flow between sympatric lineages and between allopatric and sympatric populations of the same lineage. Our major goals are to understand if genome scans for particular patterns of genetic variation could identify reinforcement, isolate the genetic basis of reinforcement, or infer the conditions under which reinforcement evolved.

  15. Genomic Signatures of Reinforcement

    Science.gov (United States)

    Goulet, Benjamin E.

    2018-01-01

    Reinforcement is the process by which selection against hybridization increases reproductive isolation between taxa. Much research has focused on demonstrating the existence of reinforcement, yet relatively little is known about the genetic basis of reinforcement or the evolutionary conditions under which reinforcement can occur. Inspired by reinforcement’s characteristic phenotypic pattern of reproductive trait divergence in sympatry but not in allopatry, we discuss whether reinforcement also leaves a distinct genomic pattern. First, we describe three patterns of genetic variation we expect as a consequence of reinforcement. Then, we discuss a set of alternative processes and complicating factors that may make the identification of reinforcement at the genomic level difficult. Finally, we consider how genomic analyses can be leveraged to inform if and to what extent reinforcement evolved in the face of gene flow between sympatric lineages and between allopatric and sympatric populations of the same lineage. Our major goals are to understand if genome scans for particular patterns of genetic variation could identify reinforcement, isolate the genetic basis of reinforcement, or infer the conditions under which reinforcement evolved. PMID:29614048

  16. Radiographic evaluation of 19 patients with Paprosky 3A and 3B submitted to acetabular review with trabecular metal wedge

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Benvindo Rosal da Fonseca Neto

    Full Text Available ABSTRACT Objective: This study is aimed at evaluating the fixation of trabecular metal wedges in patients who underwent revision of total hip arthroplasty with large acetabular bone defects. Methods: The radiographs of 19 patients (21 hips, who underwent revision of total hip arthroplasty using trabecular metal wedges from September 2010 to December 2014 were evaluated. This study included only cases of Paprosky 3A and 3B. Preoperative and postoperative images were analyzed. Non-fixation of the implant was defined by the presence of angular variation of the component higher 10 degrees or displacement greater than 6 mm. Patients with follow-up times of less than 24 months or who did not attend the last two appointments were excluded from the study. Results: The mean follow-up time was 39.4 months (25-61. Fixation was achieved in all cases despite its complexity. There was only one case of dislocation that was treated with open reduction. One case developed infection, and was surgically approached on two occasions, with extensive debridement and intravenous antibiotics following protocol, with good evolution. Conclusion: The implanted trabecular metal wedges showed excellent results in the short- and medium-term and may represent another option in the reconstruction of large acetabular defects, sometimes replacing bone reconstruction that uses bone tissue banks or autologous graft.

  17. Habituation of reinforcer effectiveness

    OpenAIRE

    David R Lloyd; David R Lloyd; Douglas J Medina; Larry W Hawk; Whitney D Fosco; Jerry B Richards

    2014-01-01

    In this paper we propose an integrative model of habituation of reinforcer effectiveness (HRE) that links behavioral and neural based explanations of reinforcement. We argue that habituation of reinforcer effectiveness (HRE) is a fundamental property of reinforcing stimuli. Most reinforcement models implicitly suggest that the effectiveness of a reinforcer is stable across repeated presentations. In contrast, an HRE approach predicts decreased effectiveness due to repeated presentation. We ar...

  18. Structural Behavior of Concrete Beams Reinforced with Basalt Fiber Reinforced Polymer (BFRP) Bars

    Science.gov (United States)

    Ovitigala, Thilan

    The main challenge for civil engineers is to provide sustainable, environmentally friendly and financially feasible structures to the society. Finding new materials such as fiber reinforced polymer (FRP) material that can fulfill the above requirements is a must. FRP material was expensive and it was limited to niche markets such as space shuttles and air industry in the 1960s. Over the time, it became cheaper and spread to other industries such as sporting goods in the 1980-1990, and then towards the infrastructure industry. Design and construction guidelines are available for carbon fiber reinforced polymer (CFRP), aramid fiber reinforced polymer (AFRP) and glass fiber reinforced polymer (GFRP) and they are currently used in structural applications. Since FRP is linear elastic brittle material, design guidelines for the steel reinforcement are not valid for FRP materials. Corrosion of steel reinforcement affects the durability of the concrete structures. FRP reinforcement is identified as an alternative to steel reinforcement in corrosive environments. Although basalt fiber reinforced polymer (BFRP) has many advantages over other FRP materials, but limited studies have been done. These studies didn't include larger BFRP bar diameters that are mostly used in practice. Therefore, larger beam sizes with larger BFRP reinforcement bar diameters are needed to investigate the flexural and shear behavior of BFRP reinforced concrete beams. Also, shear behavior of BFRP reinforced concrete beams was not yet studied. Experimental testing of mechanical properties and bond strength of BFRP bars and flexural and shear behavior of BFRP reinforced concrete beams are needed to include BFRP reinforcement bars in the design codes. This study mainly focuses on the use of BFRP bars as internal reinforcement. The test results of the mechanical properties of BFRP reinforcement bars, the bond strength of BFRP reinforcement bars, and the flexural and shear behavior of concrete beams

  19. Interaction of ring dark solitons with ring impurities in Bose-Einstein condensates

    International Nuclear Information System (INIS)

    Xue Jukui

    2005-01-01

    The interaction of ring dark solitons/vortexes with the ring-shaped repulsive and attractive impurities in two-dimensional Bose-Einstein condensates is investigated numerically. Very rich interaction phenomena are obtained, i.e., not only the interaction between the ring soliton and the impurity, but also the interaction between vortexes and the impurity. The interaction characters, i.e., snaking of ring soliton, quasitrapping or reflection of ring soliton and vortexes by the impurity, strongly depend on initial ring soliton velocity, impurity strength, initial position of ring soliton and impurity. The numerical results also reveal that ring dark solitons/vortexes can be trapped and dragged by an adiabatically moving attractive ring impurity

  20. Adapting without reinforcement.

    Science.gov (United States)

    Kheifets, Aaron; Gallistel, C Randy

    2012-11-01

    Our data rule out a broad class of behavioral models in which behavioral change is guided by differential reinforcement. To demonstrate this, we showed that the number of reinforcers missed before the subject shifted its behavior was not sufficient to drive behavioral change. What's more, many subjects shifted their behavior to a more optimal strategy even when they had not yet missed a single reinforcer. Naturally, differential reinforcement cannot be said to drive a process that shifts to accommodate to new conditions so adeptly that it doesn't miss a single reinforcer: it would have no input on which to base this shift.

  1. Storage Rings

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10 -6 eV to 3.5 x 10 12 eV (LHC, 7 x 10 12 eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams

  2. Investigations of timing during the schedule and reinforcement intervals with wheel-running reinforcement.

    Science.gov (United States)

    Belke, Terry W; Christie-Fougere, Melissa M

    2006-11-01

    Across two experiments, a peak procedure was used to assess the timing of the onset and offset of an opportunity to run as a reinforcer. The first experiment investigated the effect of reinforcer duration on temporal discrimination of the onset of the reinforcement interval. Three male Wistar rats were exposed to fixed-interval (FI) 30-s schedules of wheel-running reinforcement and the duration of the opportunity to run was varied across values of 15, 30, and 60s. Each session consisted of 50 reinforcers and 10 probe trials. Results showed that as reinforcer duration increased, the percentage of postreinforcement pauses longer than the 30-s schedule interval increased. On probe trials, peak response rates occurred near the time of reinforcer delivery and peak times varied with reinforcer duration. In a second experiment, seven female Long-Evans rats were exposed to FI 30-s schedules leading to 30-s opportunities to run. Timing of the onset and offset of the reinforcement period was assessed by probe trials during the schedule interval and during the reinforcement interval in separate conditions. The results provided evidence of timing of the onset, but not the offset of the wheel-running reinforcement period. Further research is required to assess if timing occurs during a wheel-running reinforcement period.

  3. A novel technique for impaction bone grafting in acetabular reconstruction of revision total hip arthroplasty using an ex vivo compaction device

    International Nuclear Information System (INIS)

    Akiyama, Haruhiko; Takemoto, Mitsuru; Morishima, Takkan

    2011-01-01

    Impaction bone grafting allows restoration of the acetabular bone stock in revision hip arthroplasty. The success of this technique depends largely on achieving adequate initial stability of the component. To obtain well-compacted, well-graded allograft aggregates, we developed an ex vivo compaction device to apply it in revision total hip arthroplasty on the acetabular side, and characterized mechanical properties and putative osteoconductivity of allograft aggregates. Morselized allograft bone chips were compacted ex vivo using the creep technique and subsequent impaction technique to form the bone aggregates. Impaction allograft reconstruction of the acetabulum using an ex vivo compaction device was performed on eight hips. The mechanical properties and three-dimensional micro-CT-based structural characteristics of the bone aggregates were investigated. In clinical practice, this technique offered good reproducibility in reconstructing the cavity and the segmental defects of the acetabulum, with no migration and no loosening of the component. In vitro analysis showed that the aggregates generated from 25 g fresh-frozen bone chips gained compression stiffness of 13.5-15.4 MPa under uniaxial consolidation strain. The recoil of the aggregates after compaction was 2.6-3.9%. The compression stiffness and the recoil did not differ significantly from those measured using a variety of proportions of large- and small-sized bone chips. Micro-CT-based structural analysis revealed average pore sizes of 268-299 μm and average throat diameter of pores in the bone aggregates of more than 100 μm. These sizes are desirable for osteoconduction, although large interconnected pores of more than 500 μm were detectable in association with the proportion of large-sized bone chips. Cement penetration into the aggregates was related to the proportion of large-sized bone chips. This study introduces the value of an ex vivo compaction device in bone graft compaction in clinical

  4. Habituation of reinforcer effectiveness

    Directory of Open Access Journals (Sweden)

    David R Lloyd

    2014-01-01

    Full Text Available In this paper we propose an integrative model of habituation of reinforcer effectiveness (HRE that links behavioral and neural based explanations of reinforcement. We argue that habituation of reinforcer effectiveness (HRE is a fundamental property of reinforcing stimuli. Most reinforcement models implicitly suggest that the effectiveness of a reinforcer is stable across repeated presentations. In contrast, an HRE approach predicts decreased effectiveness due to repeated presentation. We argue that repeated presentation of reinforcing stimuli decreases their effectiveness and that these decreases are described by the behavioral characteristics of habituation (McSweeney and Murphy, 2009;Rankin et al., 2009. We describe a neural model that postulates a positive association between dopamine neurotransmission and HRE. We present evidence that stimulant drugs, which artificially increase dopamine neurotransmission, disrupt (slow normally occurring HRE and also provide evidence that stimulant drugs have differential effects on operant responding maintained by reinforcers with rapid vs. slow HRE rates. We hypothesize that abnormal HRE due to genetic and/or environmental factors may underlie some behavioral disorders. For example, recent research indicates that slow-HRE is predictive of obesity. In contrast ADHD may reflect ‘accelerated-HRE’. Consideration of HRE is important for the development of effective reinforcement based treatments. Finally, we point out that most of the reinforcing stimuli that regulate daily behavior are non-consumable environmental/social reinforcers which have rapid-HRE. The almost exclusive use of consumable reinforcers with slow-HRE in pre-clinical studies with animals may have caused the importance of HRE to be overlooked. Further study of reinforcing stimuli with rapid-HRE is needed in order to understand how habituation and reinforcement interact and regulate behavior.

  5. Enhancing corrosion resistance of reinforced concrete structures with hybrid fiber reinforced concrete

    International Nuclear Information System (INIS)

    Blunt, J.; Jen, G.; Ostertag, C.P.

    2015-01-01

    Highlights: • Reinforced concrete beams were subjected to cyclic flexural loading. • Hybrid fiber reinforced composites were effective in reducing corrosion rates. • Crack resistance due to fibers increased corrosion resistance of steel rebar. • Galvanic corrosion measurements underestimated corrosion rates. • Polarization resistance measurements predicted mass loss more accurately. - Abstract: Service loads well below the yield strength of steel reinforcing bars lead to cracking of reinforced concrete. This paper investigates whether the crack resistance of Hybrid Fiber Reinforced Concrete (HyFRC) reduces the corrosion rate of steel reinforcing bars in concrete after cyclic flexural loading. The reinforcing bars were extracted to examine their surface for corrosion and compare microcell and macrocell corrosion mass loss estimates against direct gravimetric measurements. A delay in corrosion initiation and lower active corrosion rates were observed in the HyFRC beam specimens when compared to reinforced specimens containing plain concrete matrices cycled at the same flexural load

  6. Change in the structure and properties of carbon fiber-reinforced plastic with a polysulfone matrix under the effect of gamma irradiation

    International Nuclear Information System (INIS)

    Arkhipov, A.A.; Korkhov, V.P.; Pudnik, V.V.; Rodin, Yu.P.

    1993-01-01

    This article presents the results of studying the change in the structure and properties of carbon fiber-reinforced plastic with a thermoplastic matrix -- aromatic polysulfone -- as a function of the absorbed dose of gamma radiation. In view of the presence in the polysulfone macromolecules and in carbon fibers of a large number of aromatic rings and double bonds providing high radiation resistance of the composite, irradiation was carried out up to large values of absorbed doses (10 9 rad). Specimens of orthogonally reinforced composite KTMU-1 with a thickness of 1.3 mm made from aromatic polysulfone PSF-150 and carbon ribbon that absorbed various gamma radiation dosages were used. It was found that structural transformations under the effect of gamma radiation did not have a substantial effect on the mechanical properties of carbon fiber-reinforced plastic. 2 refs., 3 figs., 3 tabs

  7. Rings in drugs.

    Science.gov (United States)

    Taylor, Richard D; MacCoss, Malcolm; Lawson, Alastair D G

    2014-07-24

    We have analyzed the rings, ring systems, and frameworks in drugs listed in the FDA Orange Book to understand the frequency, timelines, molecular property space, and the application of these rings in different therapeutic areas and target classes. This analysis shows that there are only 351 ring systems and 1197 frameworks in drugs that came onto the market before 2013. Furthermore, on average six new ring systems enter drug space each year and approximately 28% of new drugs contain a new ring system. Moreover, it is very unusual for a drug to contain more than one new ring system and the majority of the most frequently used ring systems (83%) were first used in drugs developed prior to 1983. These observations give insight into the chemical novelty of drugs and potentially efficient ways to assess compound libraries and develop compounds from hit identification to lead optimization and beyond.

  8. Prestressed Ring Beam in the Church of St. Peter’s and Paul’s in Bodzanow, Design and Realization

    Science.gov (United States)

    Szydlowski, Rafal; Labuzek, Barbara; Turcza, Monika

    2017-10-01

    The present trend in architecture is designing thin. slender and spacious architectural forms. It has become the reason for searching for new solutions and finding new ways of use of the existing construction ones. Recently, the first time in Poland, the post-tensioning has been used in realization of church building. In the Church of St. Peter’s and Paul’s in Bodzanow (near Cracow) was designed circumferential ring beam post-tensioned with 4 unbounded tendons to transfer peripheral tensile forces from the roof. Thanks to the use of a prestressed ring beam hidden in the wall, large cross-section of roof girders was possible to be avoided, as well as a massive reinforced concrete ring or additional steel tie-rods. The paper presents the applied solutions in details with the theoretical calculated results as well as the results of prestressing measured in site during tensioning of tendons. Based on presented results some conclusions have been drawn.

  9. Theoretical and numerical analysis of reinforced concrete beams with confinement reinforcement

    Directory of Open Access Journals (Sweden)

    R. G. Delalibera

    Full Text Available This paper discusses the use of confinement in over-reinforced concrete beams. This reinforcement consists of square stirrups, placed in the compression zone of the beam cross-section, in order to improve its ductility. A parametric numerical study is initially performed, using a finite element computational program that considers the material nonlinearities and the confinement effect. To investigate the influence of the transverse reinforcing ratio on the beam ductility, an experimental program was also conducted. Four over-reinforced beams were tested; three beam specimens with additional transverse reinforcement to confine the beams, and one without it. All specimens were fabricated with a concrete designed for a compressive strength of 25 MPa. The experimental results show that the post-peak ductility factor is proportional to the confining reinforcement ratio, however the same is not observed for the pre-peak ductility factor, which varied randomly with changes in the confining reinforcement ratio. It was also observed from the experiments that the confinement effect tends to be smaller close to the beam neutral axis.

  10. A study of tribological behaviors of the phenolic composite coating reinforced with carbon fibers

    International Nuclear Information System (INIS)

    Song Haojie; Zhang Zhaozhu; Luo Zhuangzhu

    2007-01-01

    The nitric acid treatment was used as a method to bind acidic oxygen functional groups on carbon fiber surfaces, thereafter these fibers (CFO) and unmodified carbon fibers (CF) were incorporated into the phenolic composite coating for wear investigations. Surface analyses of the carbon fibers before and after treatments were performed by FTIR, X-ray photoelectron spectrometer (XPS). Tribological behaviors of carbon fibers filled phenolic coatings were investigated using a ring on block wear tests under dry friction condition, and the worn surfaces and the transfer films formed on the surface of counterpart ring were, respectively, studied by SEM and optical microscope. The results show that the additions of carbon fibers were able to reduce the friction coefficient of the phenolic coating and enhance the wear life of it, especially, the wear life of the phenolic coating was the best when content of carbon fibers is at 10 wt.%. Moreover, we found that the friction and wear behaviors of the phenolic coating reinforced with 10 wt.% CFO were better than those of the coating reinforced with 10 wt.% CF. FTIR and XPS analyses indicated that the oxygen functional groups, such as -OH, O-C=O, C=O, and C-O, were attached on the carbon fiber surfaces after the oxidated treatment. In both cases, appropriate treatments could effectively improve the mechanical and tribological properties in the phenolic composite coating due to the enhanced fiber-matrix interfacial bonding

  11. Positive effect of removal of subchondral bone plate for cemented acetabular component fixation in total hip arthroplasty: a randomised RSA study with ten-year follow-up.

    Science.gov (United States)

    Flivik, G; Kristiansson, I; Ryd, L

    2015-01-01

    We hypothesised that the removal of the subchondral bone plate (SCBP) for cemented acetabular component fixation in total hip arthroplasty (THA) offers advantages over retention by improving the cement-bone interface, without jeopardising implant stability. We have previously published two-year follow-up data of a randomised controlled trial (RCT), in which 50 patients with primary osteoarthritis were randomised to either retention or removal of the SCBP. The mean age of the retention group (n = 25, 13 males) was 70.0 years (sd 6.8). The mean age in the removal group (n = 25, 16 males) was 70.3 years (sd 7.9). Now we have followed up the patients at six (retention group, n = 21; removal group, n = 20) and ten years (retention group: n = 17, removal group: n = 18), administering clinical outcome questionnaires and radiostereometric analysis (RSA), and determining the presence of radiolucent lines (RLLs) on conventional radiographs. RSA demonstrated similar translation and rotation patterns up to six years. Between six and ten years, proximal acetabular component migration and changes of inclination were larger in the retention group, although the mean differences did not reach statistical significance. Differences in migration were driven by two patients in the SCBP retention group with extensive migration versus none in the SCBP removal group. The significant difference (p < 0.001) in the development of radiolucent lines in the retention group, previously observed at two years, increased even further during the course of follow-up (p < 0.001). While recognising SCBP removal is a more demanding technique, we conclude that, wherever possible, the SCBP should be removed to improve the cement-bone interface in order to maximise acetabular component stability and longevity. ©2015 The British Editorial Society of Bone & Joint Surgery.

  12. Habituation of reinforcer effectiveness.

    Science.gov (United States)

    Lloyd, David R; Medina, Douglas J; Hawk, Larry W; Fosco, Whitney D; Richards, Jerry B

    2014-01-09

    In this paper we propose an integrative model of habituation of reinforcer effectiveness (HRE) that links behavioral- and neural-based explanations of reinforcement. We argue that HRE is a fundamental property of reinforcing stimuli. Most reinforcement models implicitly suggest that the effectiveness of a reinforcer is stable across repeated presentations. In contrast, an HRE approach predicts decreased effectiveness due to repeated presentation. We argue that repeated presentation of reinforcing stimuli decreases their effectiveness and that these decreases are described by the behavioral characteristics of habituation (McSweeney and Murphy, 2009; Rankin etal., 2009). We describe a neural model that postulates a positive association between dopamine neurotransmission and HRE. We present evidence that stimulant drugs, which artificially increase dopamine neurotransmission, disrupt (slow) normally occurring HRE and also provide evidence that stimulant drugs have differential effects on operant responding maintained by reinforcers with rapid vs. slow HRE rates. We hypothesize that abnormal HRE due to genetic and/or environmental factors may underlie some behavioral disorders. For example, recent research indicates that slow-HRE is predictive of obesity. In contrast ADHD may reflect "accelerated-HRE." Consideration of HRE is important for the development of effective reinforcement-based treatments. Finally, we point out that most of the reinforcing stimuli that regulate daily behavior are non-consumable environmental/social reinforcers which have rapid-HRE. The almost exclusive use of consumable reinforcers with slow-HRE in pre-clinical studies with animals may have caused the importance of HRE to be overlooked. Further study of reinforcing stimuli with rapid-HRE is needed in order to understand how habituation and reinforcement interact and regulate behavior.

  13. Axial Compression Tests on Corroded Reinforced Concrete Columns Consolidated with Fibre Reinforced Polymers

    Directory of Open Access Journals (Sweden)

    Bin Ding

    2017-06-01

    Full Text Available Reinforced concrete structure featured by strong bearing capacity, high rigidity, good integrity, good fire resistance, and extensive applicability occupies a mainstream position in contemporary architecture. However, with the development of social economy, people need higher requirements on architectural structure; durability, especially, has been extensively researched. Because of the higher requirement on building material, ordinary reinforced concrete structure has not been able to satisfy the demand. As a result, some new materials and structures have emerged, for example, fibre reinforced polymers. Compared to steel reinforcement, fibre reinforced polymers have many advantages, such as high tensile strength, good durability, good shock absorption, low weight, and simple construction. The application of fibre reinforced polymers in architectural structure can effectively improve the durability of the concrete structure and lower the maintenance, reinforcement, and construction costs in severe environments. Based on the concepts of steel tube concrete, fibre reinforced composite material confined concrete, and fibre reinforced composite material tubed concrete, this study proposes a novel composite structure, i.e., fibre reinforced composite material and steel tube concrete composite structure. The structure was developed by pasting fibre around steel tube concrete and restraining core concrete using fibre reinforced composite material and steel tubes. The bearing capacity and ultimate deformation capacity of the structure was tested using column axial compression test.

  14. White Ring; White ring

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, H.; Yuzawa, H. [Nikken Sekkei Ltd., Osaka (Japan)

    1998-01-05

    White Ring is a citizen`s gymnasium used for figure skating and short track speed skating games of 18th Winter Olympic Games in 1998. White Ring is composed of a main-arena and a sub-arena. For the main-arena with an area 41mtimes66m, an ice link can be made by disengaging the potable floor and by flowing brine in the bridged polystyrene pipes embedded in the concrete floor. Due to the fortunate groundwater in this site, well water is used for the outside air treatment energy in 63% during heating and in 35% during cooling. Ammonia is used as a cooling medium for refrigerating facility. For the heating of audience area in the large space, heat load from the outside is reduced by enhancing the heat insulation performance of the roof of arena. The audience seats are locally heated using heaters. For the White Ring, high quality environment is realized for games through various functions of the large-scale roof of the large space. Success of the big event was expected. 15 figs., 4 tabs.

  15. Token Ring Project

    Directory of Open Access Journals (Sweden)

    Adela Ionescu

    2007-01-01

    Full Text Available Ring topology is a simple configuration used to connect processes that communicate among themselves. A number of network standards such as token ring, token bus, and FDDI are based on the ring connectivity. This article will develop an implementation of a ring of processes that communicate among themselves via pipe links. The processes are nodes in the ring. Each process reads from its standard input and writes in its standard output. N-1 process redirects the its standard output to a standard input of the process through a pipe. When the ring-structure is designed, the project can be extended to simulate networks or to implement algorithms for mutual exclusion

  16. Semi-algebraic function rings and reflectors of partially ordered rings

    CERN Document Server

    Schwartz, Niels

    1999-01-01

    The book lays algebraic foundations for real geometry through a systematic investigation of partially ordered rings of semi-algebraic functions. Real spectra serve as primary geometric objects, the maps between them are determined by rings of functions associated with the spectra. The many different possible choices for these rings of functions are studied via reflections of partially ordered rings. Readers should feel comfortable using basic algebraic and categorical concepts. As motivational background some familiarity with real geometry will be helpful. The book aims at researchers and graduate students with an interest in real algebra and geometry, ordered algebraic structures, topology and rings of continuous functions.

  17. Rotating ring-ring electrode theory and experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kellyb, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  18. The choice of surgical approach in the treatment of two-column acetabular fractures

    Directory of Open Access Journals (Sweden)

    A. A. Grin’

    2014-01-01

    Full Text Available The study aimed a comparison of treatment results in patients with two-column acetabular fractures (AO, Type C when using different operative approaches: ilioinguinal (12, Y-type (16 and a combination of posterior-lateral and ilioinguinal approaches (3. Surgical treatment was carried out not later than 3 weeks after injury. The joint congruence was reached in all the cases. The operative time, blood loss, complications, long-term results of treatment were evaluated. The study showed the effectiveness of ilioinguinal approach in case of the simple two-column fractures. When treating patients with complex fractures of the anterior column, the authors found no significant difference in operative time and intraoperative blood loss between the cases of V-type and combined approaches. In patients with two-column fractures accompanied with posterior wall lesion the time of surgery was significantly lower when using the Y-shaped approach as against the two different approaches.

  19. The diagnostic value of direct CT arthrography using MDCT in the evaluation of acetabular labral tear: with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yong-Chan; Kim, Jae Yoon [Chung-Ang University College of Medicine, Department of Orthopaedic Surgery, Seoul (Korea, Republic of); Choi, Jung-Ah; Lee, Guen Young; Kang, Heung Sik [Seoul National University Bundang Hospital, Departments of Radiology, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam (Korea, Republic of); Lee, Young-Kyun; Koo, Kyung-Hoi [Seoul National University Bundang Hospital, Orthopaedic Surgery, Seoul National University College of Medicine, Seongnam (Korea, Republic of)

    2013-05-15

    The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization. Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons. Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p = 0.013). Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear. (orig.)

  20. Topological ring currents in the "empty" ring of benzo-annelated perylenes.

    Science.gov (United States)

    Dickens, Timothy K; Mallion, Roger B

    2011-01-27

    Cyclic conjugation in benzo-annelated perylenes is examined by means of the topological π-electron ring currents calculated for each of their constituent rings, in a study that is an exact analogy of a recent investigation by Gutman et al. based on energy-effect values for the corresponding rings in each of these structures. "Classical" approaches, such as Kekulé structures, Clar "sextet" formulas, and circuits of conjugation, predict that the central ring in perylene is "empty" and thus contributes negligibly to cyclic conjugation. However, conclusions from the present calculations of topological ring currents agree remarkably with those arising from the earlier study involving energy-effect values in that, contrary to what would be predicted from the classical approaches, rings annelated in an angular fashion relative to the central ring of these perylene structures materially increase the extent of that ring's involvement in cyclic conjugation. It is suggested that such close quantitative agreement between the predictions of these two superficially very different indices (energy effect and topological ring current) might be due to the fact that, ultimately, both depend, albeit in ostensibly quite different ways, only on an adjacency matrix that contains information about the carbon-carbon connectivity of the conjugated system in question.

  1. Flexural strength using Steel Plate, Carbon Fiber Reinforced Polymer (CFRP) and Glass Fiber Reinforced Polymer (GFRP) on reinforced concrete beam in building technology

    Science.gov (United States)

    Tarigan, Johannes; Patra, Fadel Muhammad; Sitorus, Torang

    2018-03-01

    Reinforced concrete structures are very commonly used in buildings because they are cheaper than the steel structures. But in reality, many concrete structures are damaged, so there are several ways to overcome this problem, by providing reinforcement with Fiber Reinforced Polymer (FRP) and reinforcement with steel plates. Each type of reinforcements has its advantages and disadvantages. In this study, researchers discuss the comparison between flexural strength of reinforced concrete beam using steel plates and Fiber Reinforced Polymer (FRP). In this case, the researchers use Carbon Fiber Reinforced Polymer (CFRP) and Glass Fiber Reinforced Polymer (GFRP) as external reinforcements. The dimension of the beams is 15 x 25 cm with the length of 320 cm. Based on the analytical results, the strength of the beam with CFRP is 1.991 times its initial, GFRP is 1.877 times while with the steel plate is 1.646 times. Based on test results, the strength of the beam with CFRP is 1.444 times its initial, GFRP is 1.333 times while the steel plate is 1.167 times. Based on these test results, the authors conclude that beam with CFRP is the best choice for external reinforcement in building technology than the others.

  2. Kayser-Fleischer Rings

    Science.gov (United States)

    ... Support Contacts Lab Tracker/Copper Calculator Stories Programs & Research ... About Everything you need to know about Wilson Disease Kayser-Fleischer Rings Definition Kayser-Fleischer Ring: Clinical sign. Brownish-yellow ring visible around the corneo- ...

  3. Planetary Rings

    Science.gov (United States)

    Nicholson, P. D.

    2001-11-01

    A revolution in the studies in planetary rings studies occurred in the period 1977--1981, with the serendipitous discovery of the narrow, dark rings of Uranus, the first Voyager images of the tenuous jovian ring system, and the many spectacular images returned during the twin Voyager flybys of Saturn. In subsequent years, ground-based stellar occultations, HST observations, and the Voyager flybys of Uranus (1986) and Neptune (1989), as well as a handful of Galileo images, provided much additional information. Along with the completely unsuspected wealth of detail these observations revealed came an unwelcome problem: are the rings ancient or are we privileged to live at a special time in history? The answer to this still-vexing question may lie in the complex gravitational interactions recent studies have revealed between the rings and their retinues of attendant satellites. Among the four known ring systems, we see elegant examples of Lindblad and corotation resonances (first invoked in the context of galactic disks), electromagnetic resonances, spiral density waves and bending waves, narrow ringlets which exhibit internal modes due to collective instabilities, sharp-edged gaps maintained via tidal torques from embedded moonlets, and tenuous dust belts created by meteoroid impact onto parent bodies. Perhaps most puzzling is Saturn's multi-stranded, clumpy F ring, which continues to defy a simple explanation 20 years after it was first glimpsed in grainy images taken by Pioneer 11. Voyager and HST images reveal a complex, probably chaotic, dynamical interaction between unseen parent bodies within this ring and its two shepherd satellites, Pandora and Prometheus. The work described here reflects contributions by Joe Burns, Jeff Cuzzi, Luke Dones, Dick French, Peter Goldreich, Colleen McGhee, Carolyn Porco, Mark Showalter, and Bruno Sicardy, as well as those of the author. This research has been supported by NASA's Planetary Geology and Geophysics program and the

  4. Numerical Modeling of Local Penetration of Chloride-Containing Medium into Construction Elements Made of Reinforced Concrete

    Science.gov (United States)

    Ovchinnikov, I. I.; Snezhkina, O. V.; Ovchinnikov, I. G.

    2017-11-01

    The task of modeling the kinetics of chloride-containing medium penetration into construction elements out of reinforced concrete that have partially damaged anti-corrosion protective coatings is being discussed. As a result, chlorides penetrate the construction element via local surface areas which leads to irregularities between chloride dispersion volumes. The kinetics of chloride penetration is described by the equation of diffusion to solve which the CONDUCT software complex by professor S. Patankar was used. The methodology used to solve the diffusional equation is described. The results of the evaluation of concentration field in the axial section of a cylindrical construction element, which was centrally reinforced, are given. The chloride diffusion was symmetrical to the axis, the medium was applied through the central ring area equal to one third of the side surface area while the rest of the surface was isolated. It was shown that the methodology of evaluation and its algorithm allow one to evaluate the concentration field of chlorides in reinforced concrete structural elements under local or asymmetrical action of the chloride - containing medium. The example given illustrates that after a certain time interval critical the concentration of chlorides develops even in protected areas which are located far from the initial damaged area. This means that the corrosion destruction of reinforced elements develops not only in the immediate damage area, but also further away from it.

  5. Preparation for electron ring - plasma ring merging experiments in RECE-MERGE

    International Nuclear Information System (INIS)

    Taggart, D.; Sekiguchi, A.; Fleischmann, H.H.

    1986-01-01

    The formation of a mixed-CT using relativistic electron rings and gun-produced plasma rings by MERGE-ing them axially is simulated. This process is similar to the axial stacking of relativistic electron rings in RECE-Christa. The results of their first plasm production experiment are reported here. After study of the gun-produced plasma's properties is completed, the gun will be mounted at the downstream end of the vacuum tank and the source of relativistic electron rings will be at the upstream end. The two rings, formed at opposite ends of the tank, will be translated axially and merged

  6. Experimental analysis of reinforced concrete beams strengthened in bending with carbon fiber reinforced polymer

    Directory of Open Access Journals (Sweden)

    M. M. VIEIRA

    Full Text Available The use of carbon fiber reinforced polymer (CFRP has been widely used for the reinforcement of concrete structures due to its practicality and versatility in application, low weight, high tensile strength and corrosion resistance. Some construction companies use CFRP in flexural strengthening of reinforced concrete beams, but without anchor systems. Therefore, the aim of this study is analyze, through an experimental program, the structural behavior of reinforced concrete beams flexural strengthened by CFRP without anchor fibers, varying steel reinforcement and the amount of carbon fibers reinforcement layers. Thus, two groups of reinforced concrete beams were produced with the same geometric feature but with different steel reinforcement. Each group had five beams: one that is not reinforced with CFRP (reference and other reinforced with two, three, four and five layers of carbon fibers. Beams were designed using a computational routine developed in MAPLE software and subsequently tested in 4-point points flexural test up to collapse. Experimental tests have confirmed the effectiveness of the reinforcement, ratifying that beams collapse at higher loads and lower deformation as the amount of fibers in the reinforcing layers increased. However, the increase in the number of layers did not provide a significant increase in the performance of strengthened beams, indicating that it was not possible to take full advantage of strengthening applied due to the occurrence of premature failure mode in the strengthened beams for pullout of the cover that could have been avoided through the use of a suitable anchoring system for CFRP.

  7. Reinforcement Schedules in a Verbal Reinforcement Combination and Renection-Impulsivity

    OpenAIRE

    TAMASE, Koji; UEDA, Masako

    1986-01-01

    It was predicted that higher proportion of the negative reinforcement "Wrong" than that of the positive reinforcement "Right" in a reinforcement combination will produce higher proportion of the correct response and this trend will be greater in reflective children than in impulsive children. From 140 kindergarten children 30 reflective and 30 impulsive children were selected and they were given a two-hole marble-dropping task. The best performance in the ratio of correct responses was obtain...

  8. Ring faults and ring dikes around the Orientale basin on the Moon.

    Science.gov (United States)

    Andrews-Hanna, Jeffrey C; Head, James W; Johnson, Brandon; Keane, James T; Kiefer, Walter S; McGovern, Patrick J; Neumann, Gregory A; Wieczorek, Mark A; Zuber, Maria T

    2018-08-01

    The Orientale basin is the youngest and best-preserved multiring impact basin on the Moon, having experienced only modest modification by subsequent impacts and volcanism. Orientale is often treated as the type example of a multiring basin, with three prominent rings outside of the inner depression: the Inner Rook Montes, the Outer Rook Montes, and the Cordillera. Here we use gravity data from NASA's Gravity Recovery and Interior Laboratory (GRAIL) mission to reveal the subsurface structure of Orientale and its ring system. Gradients of the gravity data reveal a continuous ring dike intruded into the Outer Rook along the plane of the fault associated with the ring scarp. The volume of this ring dike is ~18 times greater than the volume of all extrusive mare deposits associated with the basin. The gravity gradient signature of the Cordillera ring indicates an offset along the fault across a shallow density interface, interpreted to be the base of the low-density ejecta blanket. Both gravity gradients and crustal thickness models indicate that the edge of the central cavity is shifted inward relative to the equivalent Inner Rook ring at the surface. Models of the deep basin structure show inflections along the crust-mantle interface at both the Outer Rook and Cordillera rings, indicating that the basin ring faults extend from the surface to at least the base of the crust. Fault dips range from 13-22° for the Cordillera fault in the northeastern quadrant, to 90° for the Outer Rook in the northwestern quadrant. The fault dips for both outer rings are lowest in the northeast, possibly due to the effects of either the direction of projectile motion or regional gradients in pre-impact crustal thickness. Similar ring dikes and ring faults are observed around the majority of lunar basins.

  9. Groups, rings, modules

    CERN Document Server

    Auslander, Maurice

    2014-01-01

    This classic monograph is geared toward advanced undergraduates and graduate students. The treatment presupposes some familiarity with sets, groups, rings, and vector spaces. The four-part approach begins with examinations of sets and maps, monoids and groups, categories, and rings. The second part explores unique factorization domains, general module theory, semisimple rings and modules, and Artinian rings. Part three's topics include localization and tensor products, principal ideal domains, and applications of fundamental theorem. The fourth and final part covers algebraic field extensions

  10. Saturn's Rings Edge-on

    Science.gov (United States)

    1995-01-01

    In one of nature's most dramatic examples of 'now-you see-them, now-you-don't', NASA's Hubble Space Telescope captured Saturn on May 22, 1995 as the planet's magnificent ring system turned edge-on. This ring-plane crossing occurs approximately every 15 years when the Earth passes through Saturn's ring plane.For comparison, the top picture was taken by Hubble on December 1, 1994 and shows the rings in a more familiar configuration for Earth observers.The bottom picture was taken shortly before the ring plane crossing. The rings do not disappear completely because the edge of the rings reflects sunlight. The dark band across the middle of Saturn is the shadow of the rings cast on the planet (the Sun is almost 3 degrees above the ring plane.) The bright stripe directly above the ring shadow is caused by sunlight reflected off the rings onto Saturn's atmosphere. Two of Saturn's icy moons are visible as tiny starlike objects in or near the ring plane. They are, from left to right, Tethys (slightly above the ring plane) and Dione.This observation will be used to determine the time of ring-plane crossing and the thickness of the main rings and to search for as yet undiscovered satellites. Knowledge of the exact time of ring-plane crossing will lead to an improved determination of the rate at which Saturn 'wobbles' about its axis (polar precession).Both pictures were taken with Hubble's Wide Field Planetary Camera 2. The top image was taken in visible light. Saturn's disk appears different in the bottom image because a narrowband filter (which only lets through light that is not absorbed by methane gas in Saturn's atmosphere) was used to reduce the bright glare of the planet. Though Saturn is approximately 900 million miles away, Hubble can see details as small as 450 miles across.The Wide Field/Planetary Camera 2 was developed by the Jet Propulsion Laboratory and managed by the Goddard Spaced Flight Center for NASA's Office of Space Science.This image and other images and

  11. The Rotating Ring-Ring Electrode. Theory and Experiment

    NARCIS (Netherlands)

    Kuiken, H.K.; Bakkers, E.P.A.M.; Ligthart, H.; Kelly, J.J.

    2000-01-01

    A model is presented for the rotating ring-ring electrode. Although the electrode is defined by four characteristic lengths, it is shown that the collection efficiency depends on only two dimensionless parameters. A simple relationship between these and the corresponding parameters for the rotating

  12. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  13. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  14. Management of Reinforcement Corrosion

    DEFF Research Database (Denmark)

    Küter, André; Geiker, Mette Rica; Møller, Per

    Reinforcement corrosion is the most important cause for deterioration of reinforced concrete structures, both with regard to costs and consequences. Thermodynamically consistent descriptions of corrosion mechanisms are expected to allow the development of innovative concepts for the management...... of reinforcement corrosion....

  15. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study.

    Science.gov (United States)

    Liu, Feng; Chen, Zhefeng; Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin

    2012-01-01

    Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

  16. Wear Analysis of Top Piston Ring to Reduce Top Ring Reversal Bore Wear

    Directory of Open Access Journals (Sweden)

    P. Ilanthirayan

    2017-12-01

    Full Text Available The piston rings are the most important part in engine which controls the lubricating oil consumption and blowby of the gases. The lubricating film of oil is provided to seal of gases towards crankcase and also to give smooth friction free translatory motion between rings and liner. Of the three rings present top ring is more crucial as it does the main work of restricting gases downwards the crankcase. Boundary lubrication is present at the Top dead centre (TDC and Bottom dead centre (BDC of the liner surface. In addition to this, top ring is exposed to high temperature gases which makes the oil present near the top ring to get evaporated and decreasing its viscosity, making metal-metal contact most of the time. Due to this at TDC, excess wear happens on the liner which is termed as Top ring reversal bore wear. The wear rate depends upon many parameters such as lubrication condition, viscosity index, contact type, normal forces acting on ring, geometry of ring face, surface roughness, material property. The present work explores the wear depth for different geometries of barrel ring using Finite Element model with the help of Archard wear law and the same is validated through experimentation. The study reveals that Asymmetric barrel rings have less contact pressure which in turn reduces the wear at Top dead centre.

  17. PREFACE: Special section on vortex rings Special section on vortex rings

    Science.gov (United States)

    Fukumoto, Yasuhide

    2009-10-01

    This special section of Fluid Dynamics Research includes five articles on vortex rings in both classical and quantum fluids. The leading scientists of the field describe the trends in and the state-of-the-art development of experiments, theories and numerical simulations of vortex rings. The year 2008 was the 150th anniversary of 'vortex motion' since Hermann von Helmholtz opened up this field. In 1858, Helmholtz published a paper in Crelle's Journal which put forward the concept of 'vorticity' and made the first analysis of vortex motion. Fluid mechanics before that was limited to irrotational motion. In the absence of vorticity, the motion of an incompressible homogeneous fluid is virtually equivalent to a rigid-body motion in the sense that the fluid motion is determined once the boundary configuration is specified. Helmholtz proved, among other things, that, without viscosity, a vortex line is frozen into the fluid. This Helmholtz's law immediately implies the preservation of knots and links of vortex lines and its implication is enormous. One of the major trends of fluid mechanics since the latter half of the 20th century is to clarify the topological meaning of Helmholtz's law and to exploit it to develop theoretical and numerical methods to find the solutions of the Euler equations and to develop experimental techniques to gain an insight into fluid motion. Vortex rings are prominent coherent structures in a variety of fluid motions from the microscopic scale, through human and mesoscale to astrophysical scales, and have attracted people's interest. The late professor Philip G Saffman (1981) emphasized the significance of studies on vortex rings. One particular motion exemplifies the whole range of problems of vortex motion and is also a commonly known phenomenon, namely the vortex ring or smoke ring. Vortex rings are easily produced by dropping drops of one liquid into another, or by puffing fluid out of a hole, or by exhaling smoke if one has the skill

  18. Vortex rings

    CERN Document Server

    Akhmetov, D G

    2009-01-01

    This text on vortex rings covers their theoretical foundation, systematic investigations, and practical applications such as the extinction of fires at gushing oil wells. It pays special attention to the formation and motion of turbulent vortex rings.

  19. A very rare case with neglected hip dislocation coexisted with posterior acetabular lip fracture

    Directory of Open Access Journals (Sweden)

    Samet Karabulut

    2011-06-01

    Full Text Available Neglected hip dislocation is a rare situation among children. The coexistence of acetabulum fracture is less common. The result of treatment depends on the time of diagnosis. Early treatment is mandatory in such cases. Seven years old female brought to our outpatient clinic with the complaints of right hip pain and walking difficulty. Her parents said that she had fallen from a horse one month ago. X-ray and CT showed a posterior dislocation of her right hip and a fracture on her right posterior acetabular lip. We performed an open reduction via posterior approach. Because the hip was unstable we fixed the femoral head to the acetabulum by a Kirshner wire. Pelvipedal cast was applied after the operation for 6 weeks. After 6 months avascular necrosis (AVN developed on her right femoral head, the range of motion (ROM of the hip was restricted and she had minimal pain on her right hip. J Clin Exp Invest 2011;2(2:228-31

  20. FUZZY RINGS AND ITS PROPERTIES

    Directory of Open Access Journals (Sweden)

    Karyati Karyati

    2017-01-01

      One of algebraic structure that involves a binary operation is a group that is defined  an un empty set (classical with an associative binary operation, it has identity elements and each element has an inverse. In the structure of the group known as the term subgroup, normal subgroup, subgroup and factor group homomorphism and its properties. Classical algebraic structure is developed to algebraic structure fuzzy by the researchers as an example semi group fuzzy and fuzzy group after fuzzy sets is introduced by L. A. Zadeh at 1965. It is inspired of writing about semi group fuzzy and group of fuzzy, a research on the algebraic structure of the ring is held with reviewing ring fuzzy, ideal ring fuzzy, homomorphism ring fuzzy and quotient ring fuzzy with its properties. The results of this study are obtained fuzzy properties of the ring, ring ideal properties fuzzy, properties of fuzzy ring homomorphism and properties of fuzzy quotient ring by utilizing a subset of a subset level  and strong level  as well as image and pre-image homomorphism fuzzy ring.   Keywords: fuzzy ring, subset level, homomorphism fuzzy ring, fuzzy quotient ring

  1. Effects of partial reinforcement and time between reinforced trials on terminal response rate in pigeon autoshaping.

    Science.gov (United States)

    Gottlieb, Daniel A

    2006-03-01

    Partial reinforcement often leads to asymptotically higher rates of responding and number of trials with a response than does continuous reinforcement in pigeon autoshaping. However, comparisons typically involve a partial reinforcement schedule that differs from the continuous reinforcement schedule in both time between reinforced trials and probability of reinforcement. Two experiments examined the relative contributions of these two manipulations to asymptotic response rate. Results suggest that the greater responding previously seen with partial reinforcement is primarily due to differential probability of reinforcement and not differential time between reinforced trials. Further, once established, differences in responding are resistant to a change in stimulus and contingency. Secondary response theories of autoshaped responding (theories that posit additional response-augmenting or response-attenuating mechanisms specific to partial or continuous reinforcement) cannot fully accommodate the current body of data. It is suggested that researchers who study pigeon autoshaping train animals on a common task prior to training them under different conditions.

  2. Bioinspired Interfacial Chelating-like Reinforcement Strategy toward Mechanically Enhanced Lamellar Materials.

    Science.gov (United States)

    Chen, Ke; Zhang, Shuhao; Li, Anran; Tang, Xuke; Li, Lidong; Guo, Lin

    2018-05-22

    Many biological organisms usually derived from the ordered assembly of heterogeneous, hierarchical inorganic/organic constituents exhibit outstanding mechanical integration, but have proven to be difficult to produce the combination of excellent mechanical properties, such as strength, toughness, and light weight, by merely mimicking their component and structural characteristics. Herein, inspired by biologically strong chelating interactions of phytic acid (PA) or IP6 in many biomaterials, we present a biologically interfacial chelating-like reinforcement (BICR) strategy for fabrication of a highly dense ordered "brick-and-mortar" microstructure by incorporating tiny amounts of a natural chelating agent ( e. g., PA) into the interface or the interlamination of a material ( e. g., graphene oxide (GO)), which shows joint improvement in hardness (∼41.0%), strength (∼124.1%), maximum Young's modulus (∼134.7%), and toughness (∼118.5%) in the natural environment. Besides, for different composite matrix systems and artificial chelating agents, the BICR strategy has been proven successful for greatly enhancing their mechanical properties, which is superior to many previous reinforcing approaches. This point can be mainly attributed to the stronger noncovalent cross-linking interactions such as dense hydrogen bonds between the richer phosphate (hydroxyl) groups on its cyclohexanehexol ring and active sites of GO, giving rise to the larger energy dissipation at its hybrid interfaces. It is also simple and environmentally friendly for further scale-up fabrication and can be readily extended to other material systems, which opens an advanced reinforcement route to construct structural materials with high mechanical performance in an efficient way for practical applications.

  3. Influence of transverse reinforcement on perforation resistance of reinforced concrete slabs under hard missile impact

    International Nuclear Information System (INIS)

    Orbovic, Nebojsa; Sagals, Genadijs; Blahoianu, Andrei

    2015-01-01

    This paper describes the work conducted by the Canadian Nuclear Safety Commission (CNSC) related to the influence of transverse reinforcement on perforation capacity of reinforced concrete (RC) slabs under “hard” missile impact (impact with negligible missile deformations). The paper presents the results of three tests on reinforced concrete slabs conducted at VTT Technical Research Centre (Finland), along with the numerical simulations as well as a discussion of the current code provisions related to impactive loading. Transverse reinforcement is widely used for improving the shear and punching strength of concrete structures. However, the effect of this reinforcement on the perforation resistance under localized missile impact is still unclear. The goal of this paper is to fill the gap in the current literature related to this topic. Based on similar tests designed by the authors with missile velocity below perforation velocity, it was expected that transverse reinforcement would improve the perforation resistance. Three slabs were tested under almost identical conditions with the only difference being the transverse reinforcement. One slab was designed without transverse reinforcement, the second one with the transverse reinforcement in form of conventional stirrups with hooks and the third one with the transverse reinforcement in form of T-headed bars. Although the transverse reinforcement reduced the overall damage of the slabs (the rear face scabbing), the conclusion from the tests is that the transverse reinforcement does not have important influence on perforation capacity of concrete slabs under rigid missile impact. The slab with T-headed bars presented a slight improvement compared to the baseline specimen without transverse reinforcement. The slab with conventional stirrups presented slightly lower perforation capacity (higher residual missile velocity) than the slab without transverse reinforcement. In conclusion, the performed tests show slightly

  4. Polarization Insensitivity in Double-Split Ring and Triple-Split Ring Terahertz Resonators

    International Nuclear Information System (INIS)

    Wu Qian-Nan; Lan Feng; Tang Xiao-Pin; Yang Zi-Qiang

    2015-01-01

    A modified double-split ring resonator and a modified triple-split ring resonator, which offer polarization-insensitive performance, are investigated, designed and fabricated. By displacing the two gaps of the conventional double-split ring resonator away from the center, the second resonant frequency for the 0° polarized wave and the resonant frequency for the 90° polarized wave become increasingly close to each other until they are finally identical. Theoretical and experimental results show that the modified double-split ring resonator and the modified triple-split ring resonator are insensitive to different polarized waves and show strong resonant frequency dips near 433 and 444 GHz, respectively. The results of this work suggest new opportunities for the investigation and design of polarization-dependent terahertz devices based on split ring resonators. (paper)

  5. Transfer of metallic debris from the metal surface of an acetabular cup to artificial femoral heads by scraping: comparison between alumina and cobalt-chrome heads.

    Science.gov (United States)

    Chang, Chong Bum; Yoo, Jeong Joon; Song, Won Seok; Kim, Deug Joong; Koo, Kyung-Hoi; Kim, Hee Joong

    2008-04-01

    We aimed to investigate the transfer of metal to both ceramic (alumina) and metal (cobalt-chrome) heads that were scraped by a titanium alloy surface under different load conditions. The ceramic and metal heads for total hip arthroplasties were scraped by an acetabular metal shell under various loads using a creep tester. Microstructural changes in the scraped area were visualized with a scanning electron microscope, and chemical element changes were assessed using an energy dispersive X-ray spectrometry. Changes in the roughness of the scraped surface were evaluated by a three-dimensional surface profiling system. Metal transfer to the ceramic and metal heads began to be detectable at a 10 kg load, which could be exerted by one-handed force. The surface roughness values significantly increased with increasing test loads in both heads. When the contact force increased, scratching of the head surface occurred in addition to the transfer of metal. The results documented that metallic debris was transferred from the titanium alloy acetabular shell to both ceramic and metal heads by minor scraping. This study suggests that the greatest possible effort should be made to protect femoral heads, regardless of material, from contact with metallic surfaces during total hip arthroplasty.

  6. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    Science.gov (United States)

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  7. Finite element modelling of concrete beams reinforced with hybrid fiber reinforced bars

    Science.gov (United States)

    Smring, Santa binti; Salleh, Norhafizah; Hamid, NoorAzlina Abdul; Majid, Masni A.

    2017-11-01

    Concrete is a heterogeneous composite material made up of cement, sand, coarse aggregate and water mixed in a desired proportion to obtain the required strength. Plain concrete does not with stand tension as compared to compression. In order to compensate this drawback steel reinforcement are provided in concrete. Now a day, for improving the properties of concrete and also to take up tension combination of steel and glass fibre-reinforced polymer (GFRP) bars promises favourable strength, serviceability, and durability. To verify its promise and support design concrete structures with hybrid type of reinforcement, this study have investigated the load-deflection behaviour of concrete beams reinforced with hybrid GFRP and steel bars by using ATENA software. Fourteen beams, including six control beams reinforced with only steel or only GFRP bars, were analysed. The ratio and the ordinate of GFRP to steel were the main parameters investigated. The behaviour of these beams was investigated via the load-deflection characteristics, cracking behaviour and mode of failure. Hybrid GFRP-Steel reinforced concrete beam showed the improvement in both ultimate capacity and deflection concomitant to the steel reinforced concrete beam. On the other hand, finite element (FE) modelling which is ATENA were validated with previous experiment and promising the good result to be used for further analyses and development in the field of present study.

  8. RINGED ACCRETION DISKS: EQUILIBRIUM CONFIGURATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, D.; Stuchlík, Z., E-mail: d.pugliese.physics@gmail.com, E-mail: zdenek.stuchlik@physics.cz [Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Faculty of Philosophy and Science, Silesian University in Opava, Bezručovo náměstí 13, CZ-74601 Opava (Czech Republic)

    2015-12-15

    We investigate a model of a ringed accretion disk, made up by several rings rotating around a supermassive Kerr black hole attractor. Each toroid of the ringed disk is governed by the general relativity hydrodynamic Boyer condition of equilibrium configurations of rotating perfect fluids. Properties of the tori can then be determined by an appropriately defined effective potential reflecting the background Kerr geometry and the centrifugal effects. The ringed disks could be created in various regimes during the evolution of matter configurations around supermassive black holes. Therefore, both corotating and counterrotating rings have to be considered as being a constituent of the ringed disk. We provide constraints on the model parameters for the existence and stability of various ringed configurations and discuss occurrence of accretion onto the Kerr black hole and possible launching of jets from the ringed disk. We demonstrate that various ringed disks can be characterized by a maximum number of rings. We present also a perturbation analysis based on evolution of the oscillating components of the ringed disk. The dynamics of the unstable phases of the ringed disk evolution seems to be promising in relation to high-energy phenomena demonstrated in active galactic nuclei.

  9. Stirling engine piston ring

    Science.gov (United States)

    Howarth, Roy B.

    1983-01-01

    A piston ring design for a Stirling engine wherein the contact pressure between the piston and the cylinder is maintained at a uniform level, independent of engine conditions through a balancing of the pressure exerted upon the ring's surface and thereby allowing the contact pressure on the ring to be predetermined through the use of a preloaded expander ring.

  10. Physics of quantum rings

    International Nuclear Information System (INIS)

    Fomin, Vladimir M.

    2014-01-01

    Presents the new class of materials of quantum rings. Provides an elemental basis for low-cost high-performance devices promising for electronics, optoelectronics, spintronics and quantum information processing. Explains the physical properties of quantum rings to cover a gap in scientific literature. Presents the application of most advanced nanoengineering and nanocharacterization techniques. This book deals with a new class of materials, quantum rings. Innovative recent advances in experimental and theoretical physics of quantum rings are based on the most advanced state-of-the-art fabrication and characterization techniques as well as theoretical methods. The experimental efforts allow to obtain a new class of semiconductor quantum rings formed by capping self-organized quantum dots grown by molecular beam epitaxy. Novel optical and magnetic properties of quantum rings are associated with non-trivial topologies at the nanoscale. An adequate characterization of quantum rings is possible on the basis of modern characterization methods of nanostructures, such as Scanning Tunneling Microscopy. A high level of complexity is demonstrated to be needed for a dedicated theoretical model to adequately represent the specific features of quantum rings. The findings presented in this book contribute to develop low-cost high-performance electronic, spintronic, optoelectronic and information processing devices based on quantum rings.

  11. How does the blue-ringed octopus (Hapalochlaena lunulata) flash its blue rings?

    Science.gov (United States)

    Mäthger, Lydia M; Bell, George R R; Kuzirian, Alan M; Allen, Justine J; Hanlon, Roger T

    2012-11-01

    The blue-ringed octopus (Hapalochlaena lunulata), one of the world's most venomous animals, has long captivated and endangered a large audience: children playing at the beach, divers turning over rocks, and biologists researching neurotoxins. These small animals spend much of their time in hiding, showing effective camouflage patterns. When disturbed, the octopus will flash around 60 iridescent blue rings and, when strongly harassed, bite and deliver a neurotoxin that can kill a human. Here, we describe the flashing mechanism and optical properties of these rings. The rings contain physiologically inert multilayer reflectors, arranged to reflect blue-green light in a broad viewing direction. Dark pigmented chromatophores are found beneath and around each ring to enhance contrast. No chromatophores are above the ring; this is unusual for cephalopods, which typically use chromatophores to cover or spectrally modify iridescence. The fast flashes are achieved using muscles under direct neural control. The ring is hidden by contraction of muscles above the iridophores; relaxation of these muscles and contraction of muscles outside the ring expose the iridescence. This mechanism of producing iridescent signals has not previously been reported in cephalopods and we suggest that it is an exceptionally effective way to create a fast and conspicuous warning display.

  12. Repeated self-healing of microvascular carbon fibre reinforced polymer composites

    International Nuclear Information System (INIS)

    Coope, T S; Trask, R S; Bond, I P; Wass, D F

    2014-01-01

    A self-healing, high performance, carbon fibre reinforced polymer (CFRP) composite is demonstrated by embedding a Lewis-acid catalytic curing agent within a laminate, manufactured using out of autoclave (OOA) composite manufacturing methods. Two configurations of healing agent delivery, pre-mixed and autonomous mixing, are investigated via injection of a healing agent through bio-inspired microvascular channels exposed on Mode I fractured crack planes. Healing is effected when an epoxy resin-solvent healing agent mixture reaches the boundary of embedded solid-state scandium(III) triflate (Sc(OTf) 3 ) catalyst, located on the crack plane, to initiate the ring-opening polymerisation (ROP) of epoxides. Tailored self-healing agents confer high healing efficiency values after multiple healing cycles (69–108%) to successfully mitigate against crack propagation within the composite microstructure. (paper)

  13. α-Skew π-McCoy Rings

    Directory of Open Access Journals (Sweden)

    Areej M. Abduldaim

    2013-01-01

    Full Text Available As a generalization of α-skew McCoy rings, we introduce the concept of α-skew π-McCoy rings, and we study the relationships with another two new generalizations, α-skew π1-McCoy rings and α-skew π2-McCoy rings, observing the relations with α-skew McCoy rings, π-McCoy rings, α-skew Armendariz rings, π-regular rings, and other kinds of rings. Also, we investigate conditions such that α-skew π1-McCoy rings imply α-skew π-McCoy rings and α-skew π2-McCoy rings. We show that in the case where R is a nonreduced ring, if R is 2-primal, then R is an α-skew π-McCoy ring. And, let R be a weak (α,δ-compatible ring; if R is an α-skew π1-McCoy ring, then R is α-skew π2-McCoy.

  14. A Feasibility Study into the Use of Three-Dimensional Printer Modelling in Acetabular Fracture Surgery

    Directory of Open Access Journals (Sweden)

    A. W. Yu

    2015-01-01

    Full Text Available There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient’s unique anatomy can only lead to improved outcomes.

  15. VUV optical ring resonator for Duke storage ring free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Park, S.H.; Litvinenko, V.N.; Madey, J.M.J. [Duke Univ., Durham, NC (United States)] [and others

    1995-12-31

    The conceptual design of the multifaceted-mirror ring resonator for Duke storage ring VUV FEL is presented. The expected performance of the OK-4 FEL with ring resonator is described. We discuss in this paper our plans to study reflectivity of VUV mirrors and their resistivity to soft X-ray spontaneous radiation from OK-4 undulator.

  16. Methods for producing reinforced carbon nanotubes

    Science.gov (United States)

    Ren, Zhifen [Newton, MA; Wen, Jian Guo [Newton, MA; Lao, Jing Y [Chestnut Hill, MA; Li, Wenzhi [Brookline, MA

    2008-10-28

    Methods for producing reinforced carbon nanotubes having a plurality of microparticulate carbide or oxide materials formed substantially on the surface of such reinforced carbon nanotubes composite materials are disclosed. In particular, the present invention provides reinforced carbon nanotubes (CNTs) having a plurality of boron carbide nanolumps formed substantially on a surface of the reinforced CNTs that provide a reinforcing effect on CNTs, enabling their use as effective reinforcing fillers for matrix materials to give high-strength composites. The present invention also provides methods for producing such carbide reinforced CNTs.

  17. Interaction Region Design for a Ring-Ring LHeC

    CERN Document Server

    Thompson, L N S; Bernard, N R; Fitterer, M; Holzer, B; Klein, M; Kostka, P

    2011-01-01

    tively low energy and moderately high intensity provides high luminosity TeV-scale e-p collisions at one of the LHC interaction points, running simultaneously with existing experiments. Two designs are studied; an electron ring situated in the LHC tunnel, and an electron linac. The focus of this paper is on the ring design. Designing an e-p machine presents interesting accelerator physics and design challenges, particularly when considering the interaction region. These include coupled optics, beam separation and unconventional mini-beta focusing schemes. Designs are constrained by an array of interdependent factors, including beam-beam interaction, detector dimensions and acceptance, luminosity and synchrotron radiation. Methods of addressing these complex issues are discussed. The current designs for the LHeC Ring-Ring interaction region and long straight section are presented and discussed, in the context of the project goals and design challenges encountered. Future developments and work are also discusse...

  18. Analysis of 18 F-FDG uptake patterns in PET for diagnosis of septic and aseptic loosening after total hip arthroplasty

    International Nuclear Information System (INIS)

    Cremerius, U.; Niethard, F.U.; Mumme, T.; Reinartz, P.; Wirtz, D.; Buell, U.

    2003-01-01

    Aim: Identification of typical patterns for fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET) to detect aseptic loosening of hip prosthesis (acetabular and/or femoral component) and prosthetic infection. Methods: 18 patients with painful hip prosthesis underwent PET using a dedicated full ring scanner after application of 200-300 MBq FDG. The interface between bone and surrounding soft tissue or bone as displayed on coronal slices was divided into 12 segments in accordance with the classifications of Delee and Gruen. FDG uptake in each of the segments was scored (0-3) by two independent observers. Intraoperative findings were regarded as the gold standard. Results: After surgical revision 14 acetabular components and 9 femoral components were found to be loose and prosthetic infection was present in 7 prostheses. Loosening of the acetabular component was correlated to enhanced uptake in the middle of the acetabular interface, while loosening of the femoral component was correlated to enhanced uptake in the proximal and middle segment of the lateral femoral interface and the proximal segment of the medial femoral interface. A similar pattern was found in prosthetic infection with high uptake along the middle portion of the lateral femoral interface. In 6 of 7 infected prostheses loosening of the acetabular and of the femoral component was present. Taking the typical uptake patterns as criteria for loosening and grade 3 uptake as an additional criterion for septic loosening the accuracy of PET imaging in the detection of loosening of the acetabular or the femoral component and of prosthetic infection was 72, 78 and 89%, respectively. Conclusion: This pilot study presents FDG-PET as a promising diagnostic tool for patients with painful hip prostheses. Its clinical value should be evaluated in a larger patient population. (orig.) [de

  19. Discrete element analysis is a valid method for computing joint contact stress in the hip before and after acetabular fracture.

    Science.gov (United States)

    Townsend, Kevin C; Thomas-Aitken, Holly D; Rudert, M James; Kern, Andrew M; Willey, Michael C; Anderson, Donald D; Goetz, Jessica E

    2018-01-23

    Evaluation of abnormalities in joint contact stress that develop after inaccurate reduction of an acetabular fracture may provide a potential means for predicting the risk of developing post-traumatic osteoarthritis. Discrete element analysis (DEA) is a computational technique for calculating intra-articular contact stress distributions in a fraction of the time required to obtain the same information using the more commonly employed finite element analysis technique. The goal of this work was to validate the accuracy of DEA-computed contact stress against physical measurements of contact stress made in cadaveric hips using Tekscan sensors. Four static loading tests in a variety of poses from heel-strike to toe-off were performed in two different cadaveric hip specimens with the acetabulum intact and again with an intentionally malreduced posterior wall acetabular fracture. DEA-computed contact stress was compared on a point-by-point basis to stress measured from the physical experiments. There was good agreement between computed and measured contact stress over the entire contact area (correlation coefficients ranged from 0.88 to 0.99). DEA-computed peak contact stress was within an average of 0.5 MPa (range 0.2-0.8 MPa) of the Tekscan peak stress for intact hips, and within an average of 0.6 MPa (range 0-1.6 MPa) for fractured cases. DEA-computed contact areas were within an average of 33% of the Tekscan-measured areas (range: 1.4-60%). These results indicate that the DEA methodology is a valid method for accurately estimating contact stress in both intact and fractured hips. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Uniquely Strongly Clean Group Rings

    Institute of Scientific and Technical Information of China (English)

    WANG XIU-LAN

    2012-01-01

    A ring R is called clean if every element is the sum of an idempotent and a unit,and R is called uniquely strongly clean (USC for short) if every element is uniquely the sum of an idempotent and a unit that commute.In this article,some conditions on a ring R and a group G such that RG is clean are given.It is also shown that if G is a locally finite group,then the group ring RG is USC if and only if R is USC,and G is a 2-group.The left uniquely exchange group ring,as a middle ring of the uniquely clean ring and the USC ring,does not possess this property,and so does the uniquely exchange group ring.

  1. Tribological behavior of the carbon fiber reinforced polyphenylene sulfide (PPS) composite coating under dry sliding and water lubrication

    International Nuclear Information System (INIS)

    Xu Haiyan; Feng Zhizhong; Chen Jianmin; Zhou Huidi

    2006-01-01

    Carbon fiber reinforced polyphenylene sulphide (PPS) composite coatings (the mass fraction of the carbon fiber varied from 1 to 5 wt%) were prepared by flame spraying. The microstructure and physical properties of the composite coating were studied. The friction and wear characteristics of the PPS coating and carbon fiber reinforced PPS composite coating under dry- and water-lubricated sliding against stainless steel were comparatively investigated using a block-ring tester. The composite coatings showed lower friction coefficient and higher wear rate than pure PPS coatings under dry sliding. Under water-lubricated condition, the composite coatings showed better wear resistance than under dry. Under water-lubricated condition the tribological behaviors of the 3 wt% carbon fiber reinforced composite coating also were investigated under different sliding speed and load. The result showed that the sliding speed had little effect on the tribological properties, but the load affected greatly on that of the composite coatings. The morphologies of the worn surfaces of the composite coatings and the counterpart steel were analyzed by means of scanning electron microscopy (SEM), coupled with an energy-dispersive X-ray spectrometer (EDS) for compositional analysis

  2. Carbon Fiber Reinforced Polymer Grids for Shear and End Zone Reinforcement in Bridge Beams

    Science.gov (United States)

    2018-01-01

    Corrosion of reinforcing steel reduces life spans of bridges throughout the United States; therefore, using non-corroding carbon fiber reinforced polymer (CFRP) reinforcement is seen as a way to increase service life. The use of CFRP as the flexural ...

  3. Influence of ring growth rate on damage development in hot ring rolling

    NARCIS (Netherlands)

    Wang, C.; Geijselaers, H. J.M.; Omerspahic, E.; Recina, V.; van den Boogaard, A. H.

    2015-01-01

    As an incremental forming process of bulk metal, ring rolling provides a cost effective process route to manufacture seamless rings. In the production of hot rolled rings, defects such as porosity can sometimes be found in high alloyed steel, manufactured from ingots having macro-segregation. For

  4. Ring rotational speed trend analysis by FEM approach in a Ring Rolling process

    Science.gov (United States)

    Allegri, G.; Giorleo, L.; Ceretti, E.

    2018-05-01

    Ring Rolling is an advanced local incremental forming technology to fabricate directly precise seamless ring-shape parts with various dimensions and materials. In this process two different deformations occur in order to reduce the width and the height of a preform hollow ring; as results a diameter expansion is obtained. In order to guarantee a uniform deformation, the preform is forced toward the Driver Roll whose aim is to transmit the rotation to the ring. The ring rotational speed selection is fundamental because the higher is the speed the higher will be the axial symmetry of the deformation process. However, it is important to underline that the rotational speed will affect not only the final ring geometry but also the loads and energy needed to produce it. Despite this importance in industrial environment, usually, a constant value for the Driver Roll angular velocity is set so to result in a decreasing trend law for the ring rotational speed. The main risk due to this approach is not fulfilling the axial symmetric constrain (due to the diameter expansion) and to generate a high localized ring section deformation. In order to improve the knowledge about this topic in the present paper three different ring rotational speed trends (constant, linearly increasing and linearly decreasing) were investigated by FEM approach. Results were compared in terms of geometrical and dimensional analysis, loads and energies required.

  5. Ring correlations in random networks.

    Science.gov (United States)

    Sadjadi, Mahdi; Thorpe, M F

    2016-12-01

    We examine the correlations between rings in random network glasses in two dimensions as a function of their separation. Initially, we use the topological separation (measured by the number of intervening rings), but this leads to pseudo-long-range correlations due to a lack of topological charge neutrality in the shells surrounding a central ring. This effect is associated with the noncircular nature of the shells. It is, therefore, necessary to use the geometrical distance between ring centers. Hence we find a generalization of the Aboav-Weaire law out to larger distances, with the correlations between rings decaying away when two rings are more than about three rings apart.

  6. Alpha - Skew Pi - Armendariz Rings

    Directory of Open Access Journals (Sweden)

    Areej M Abduldaim

    2018-03-01

    Full Text Available In this article we introduce a new concept called Alpha-skew Pi-Armendariz rings (Alpha - S Pi - ARas a generalization of the notion of Alpha-skew Armendariz rings.Another important goal behind studying this class of rings is to employ it in order to design a modern algorithm of an identification scheme according to the evolution of using modern algebra in the applications of the field of cryptography.We investigate general properties of this concept and give examples for illustration. Furthermore, this paperstudy the relationship between this concept and some previous notions related to Alpha-skew Armendariz rings. It clearly presents that every weak Alpha-skew Armendariz ring is Alpha-skew Pi-Armendariz (Alpha-S Pi-AR. Also, thisarticle showsthat the concepts of Alpha-skew Armendariz rings and Alpha-skew Pi- Armendariz rings are equivalent in case R is 2-primal and semiprime ring.Moreover, this paper proves for a semicommutative Alpha-compatible ringR that if R[x;Alpha] is nil-Armendariz, thenR is an Alpha-S Pi-AR. In addition, if R is an Alpha - S Pi -AR, 2-primal and semiprime ring, then N(R[x;Alpha]=N(R[x;Alpha]. Finally, we look forwardthat Alpha-skew Pi-Armendariz rings (Alpha-S Pi-ARbe more effect (due to their properties in the field of cryptography than Pi-Armendariz rings, weak Armendariz rings and others.For these properties and characterizations of the introduced concept Alpha-S Pi-AR, we aspire to design a novel algorithm of an identification scheme.

  7. 3D printing utility for surgical treatment of acetabular fractures.

    Science.gov (United States)

    Chana Rodríguez, F; Pérez Mañanes, R; Narbona Cárceles, F J; Gil Martínez, P

    2018-05-25

    Preoperative 3D modelling enables more effective diagnosis and simulates the surgical procedure. We report twenty cases of acetabular fractures with preoperative planning performed by pre-contouring synthesis plates on a 3D printed mould obtained from a computarized tomography (CT) scan. The mould impression was made with the DaVinci 1.0 printer model (XYZ Printing). After obtaining the printed hemipelvis, we proceeded to select the implant size (pelvic Matta system, Stryker ® ) that matched the characteristics of the fracture and the approach to be used. Printing the moulds took a mean of 385minutes (322-539), and 238grams of plastic were used to print the model (180-410). In all cases, anatomic reduction was obtained and intra-operative changes were not required in the initial contouring of the plates. The time needed to perform the full osteosynthesis, once the fracture had been reduced was 16.9minutes (10-24). In one case fixed with two plates, a postoperative CT scan showed partial contact of the implant with the surface of the quadrilateral plate. In the remaining cases, the contact was complete. In conclusion, our results suggest that the use of preoperative planning, by printing 3D mirror imaging models of the opposite hemipelvis and pre-contouring plates over the mould, might effectively achieve a predefined surgical objective and reduce the inherent risks in these difficult procedures. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  8. Combining noncontingent reinforcement and differential reinforcement schedules as treatment for aberrant behavior.

    OpenAIRE

    Marcus, B A; Vollmer, T R

    1996-01-01

    Research has shown that noncontingent reinforcement (NCR) can be an effective behavior-reduction procedure when based on a functional analysis. The effects of NCR may be a result of elimination of the contingency between aberrant behavior and reinforcing consequences (extinction) or frequent and free access to reinforcers that may reduce the participant's motivation to engage in aberrant behaviors or mands. If motivation is momentarily reduced, behavior such as mands may not be sensitive to p...

  9. Plasma-ring, fast-opening switch

    International Nuclear Information System (INIS)

    Hartman, C.W.; Eddleman, J.; Hammer, J.H.

    1986-01-01

    The authors discuss a fast-opening switch concept based on magnetically confined plasma rings, PROS (for Plasma Ring Opening Switch). In PROS, the plasma ring, confined by Bθ /sub and B/poloidal /sub fields of a compact torus, provide a low mass, localized conduction path between coaxial electrodes. To operate the switch, driver current is passed across the electrodes through the ring, storing inductive energy in external inductance and between the electrodes on the driver side of the ring. The ring is accelerated away from the driver by the field of the driver current and passes over a load gap transferring the current to the load. The authors distinguish two configurations in PROS, straight PROS where the electrodes are coaxial cylinders, and cone PROS with conical electrodes. In straight PROS ring acceleration takes place during the inductive store period as in foil switches, but with the localized ring providing the current path. Increased performance is predicted for the cone PROS (see figure) which employs compression of the ring in the cone during the inductive store period. Here, the B/θ /sub field of the driver forces the ring towards the apex of the cone but the force is in near balance with the opposing component of the radial equilibrium force of the ring along the cone. As a result, the ring undergoes a slow, quasistatic compression limited only by resistive decay of the ring field. Slow compression allows inductive storage with low-power drivers (homopoloar, magneto cumulative generators, high C-low V capacitor banks, etc.). Near the apex of the cone, near peak compression, the ring is allowed to enter a straight coaxial section where, because of low-mass, it rapidly accelerates to high velocity and crosses the load gap

  10. Degradation of Waterfront Reinforced Concrete Structures

    African Journals Online (AJOL)

    Key words: Degradation, reinforced concrete, Dar es Salaam port. Abstract—One of the ... especially corrosion of the reinforcement. ... Corrosion of steel reinforcement contributes .... cracks along the line of reinforcement bars and most of the ...

  11. Fusion Rings for Quantum Groups

    DEFF Research Database (Denmark)

    Andersen, Henning Haahr; Stroppel, Catharina

    2014-01-01

    We study the fusion rings of tilting modules for a quantum group at a root of unity modulo the tensor ideal of negligible tilting modules. We identify them in type A with the combinatorial rings from Korff, C., Stroppel, C.: The sl(ˆn)k-WZNW fusion ring: a combinato-rial construction...... and a realisation as quotient of quantum cohomology. Adv. Math. 225(1), 200–268, (2010) and give a similar description of the sp2n-fusion ring in terms of non-commutative symmetric functions. Moreover we give a presentation of all fusion rings in classical types as quotients of polynomial rings. Finally we also...... compute the fusion rings for type G2....

  12. The LSU Electron Storage Ring, the first commercially-built storage ring

    International Nuclear Information System (INIS)

    Sah, R.

    1990-01-01

    The Brobeck Division of Maxwell Laboratories, Inc., is building the first industrially-produced storage ring. It will be located at Louisiana State University (LSU) at the Center for Advanced Microstructures and Devices (CAMD) in Baton Rouge. The purpose of this electron storage ring is to provide intense beams of x-rays to advance the state-of-the-art in lithography and to permit research in a broad area. This facility consists of a 1.2 GeV, 400 mA electron storage ring with a 200 MeV linac injector. The magnet lattice is a Chasman-Green design (double-bend achromat), and the ring circumference is 55.2 meters. There are four 3.0 meter, dispersion-free straight sections, one for injection, one for the 500 MHz RF cavity, and two for possible future insertion devices. The storge ring construction project is in the detailed-design stage, and many systems are in the initial stages of fabrication. 4 figs., 1 tab

  13. Fusion rings and fusion ideals

    DEFF Research Database (Denmark)

    Andersen, Troels Bak

    by the so-called fusion ideals. The fusion rings of Wess-Zumino-Witten models have been widely studied and are well understood in terms of precise combinatorial descriptions and explicit generating sets of the fusion ideals. They also appear in another, more general, setting via tilting modules for quantum......This dissertation investigates fusion rings, which are Grothendieck groups of rigid, monoidal, semisimple, abelian categories. Special interest is in rational fusion rings, i.e., fusion rings which admit a finite basis, for as commutative rings they may be presented as quotients of polynomial rings...

  14. Confinement of Reinforced-Concrete Columns with Non-Code Compliant Confining Reinforcement plus Supplemental Pen-Binder

    Directory of Open Access Journals (Sweden)

    Anang Kristianto

    2012-11-01

    Full Text Available One of the important requirements for earthquake resistant building related to confinement is the use of seismic hooks in the hoop or confining reinforcement of reinforced-concrete column elements. However, installation of a confining reinforcement with a 135-degree hook is not easy. Therefore, in practice, many construction workers apply a confining reinforcement with a 90-degreehook (non-code compliant. Based on research and records of recent earthquakes in Indonesia, the use of a non-code compliant confining reinforcement for concrete columns produces structures with poor seismic performance. This paper presents a study that introduces an additional element that is expected to improve the effectiveness of concrete columns confined with a non-code compliant confining reinforcement. The additional element, named a pen-binder, is used to keep the non-code compliant confining reinforcement in place. The effectiveness of this element under pure axial concentric loading was investigatedcomprehensively.The specimens tested in this study were 18 concrete columns,with a cross-section of 170 mm x 170 mm and a height of 480 mm. The main test variables were the material type of the pen-binder, the angle of the hook, and the confining reinforcement configuration.The test results indicate that adding pen-binders can effectively improve the strength and ductility of the column specimens confined with a non-code compliant confining reinforcement

  15. [Recostruction of Extensive Acetabular Defects by Bioactive Glass Ceramics in Re-operations of Total Endoprostheses.].

    Science.gov (United States)

    Urban, K; Sponer, P

    1998-01-01

    The authors made 37 revisions on account of aseptic loosening of total endoprostheses of the hip joint using bioactive glass ceramics BAS-0 of Lasak Co. Prague. For reconstruction of large defects of the acetabulum they used a combination of different types of anti-protrusion metal baskets and granules from this material. In some instances the glass ceramic material was combined with autologous spongiosa. The longest follow-up period is over 4 years. In no instance loosening of the glass ceramic material occurred or its expulsion. All reconstructed sockets of hip joints were burdened by the patients from the third month after surgery. Harris Hip Score before operation was on average 52. During the last checkups of the patients it reached the level of 86. The authors mention complications associated with the procedure. The advantages and disadvantages of the procedure are discussed. Key words: bioactive glass ceramics, reconstruction of acetabular defect, aseptic loosening of endoprosthesis.

  16. Influence of reinforcement's corrosion into hyperstatic reinforced concrete beams: a probabilistic failure scenarios analysis

    Directory of Open Access Journals (Sweden)

    G. P. PELLIZZER

    Full Text Available AbstractThis work aims to study the mechanical effects of reinforcement's corrosion in hyperstatic reinforced concrete beams. The focus is the probabilistic determination of individual failure scenarios change as well as global failure change along time. The limit state functions assumed describe analytically bending and shear resistance of reinforced concrete rectangular cross sections as a function of steel and concrete resistance and section dimensions. It was incorporated empirical laws that penalize the steel yield stress and the reinforcement's area along time in addition to Fick's law, which models the chloride penetration into concrete pores. The reliability theory was applied based on Monte Carlo simulation method, which assesses each individual probability of failure. The probability of global structural failure was determined based in the concept of failure tree. The results of a hyperstatic reinforced concrete beam showed that reinforcements corrosion make change into the failure scenarios modes. Therefore, unimportant failure modes in design phase become important after corrosion start.

  17. USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

  18. Evaluation of ring impedance of the Photon Factory storage ring

    International Nuclear Information System (INIS)

    Kiuchi, T.; Izawa, M.; Tokumoto, S.; Hori, Y.; Sakanaka, S.; Kobayashi, M.; Kobayakawa, H.

    1992-05-01

    The loss parameters of the ducts in the Photon Factory (PF) storage ring were evaluated using the wire method and the code TBCI. Both the measurement and the calculation were done for a different bunch length (σ) ranging from 23 to 80 ps. The PF ring impedance was estimated to be |Z/n|=3.2 Ω using the broadband impedance model. The major contribution to the impedance comes from the bellows and the gate valve sections. Improvements of these components will lower the ring impedance by half. (author)

  19. Tree Rings: Timekeepers of the Past.

    Science.gov (United States)

    Phipps, R. L.; McGowan, J.

    One of a series of general interest publications on science issues, this booklet describes the uses of tree rings in historical and biological recordkeeping. Separate sections cover the following topics: dating of tree rings, dating with tree rings, tree ring formation, tree ring identification, sample collections, tree ring cross dating, tree…

  20. Finite element modeling of reinforced concrete beams with a hybrid combination of steel and aramid reinforcement

    International Nuclear Information System (INIS)

    Hawileh, R.A.

    2015-01-01

    Highlights: • Modeling of concrete beams reinforced steel and FRP bars. • Developed finite element models achieved good results. • The models are validated via comparison with experimental results. • Parametric studies are performed. - Abstract: Corrosion of steel bars has an adverse effect on the life-span of reinforced concrete (RC) members and is usually associated with crack development in RC beams. Fiber reinforced polymer (FRP) bars have been recently used to reinforce concrete members in flexure due to their high tensile strength and superior corrosion resistance properties. However, FRP materials are brittle in nature, thus RC beams reinforced with such materials would exhibit a less ductile behavior when compared to similar members reinforced with conventional steel reinforcement. Recently, researchers investigated the performance of concrete beams reinforced with a hybrid combination of steel and Aramid Fiber Reinforced Polymer (AFRP) reinforcement to maintain a reasonable level of ductility in such members. The function of the AFRP bars is to increase the load-carrying capacity, while the function of the steel bars is to ensure ductility of the flexural member upon yielding in tension. This paper presents a three-dimensional (3D) finite element (FE) model that predicted the load versus mid-span deflection response of tested RC beams conducted by other researchers with a hybrid combination of steel and AFRP bars. The developed FE models account for the constituent material nonlinearities and bond–slip behavior between the reinforcing bars and adjacent concrete surfaces. It was concluded that the developed models can accurately capture the behavior and predicts the load-carrying capacity of such RC members. In addition, a parametric study is conducted using the validated models to investigate the effect of AFRP bar size, FRP material type, bond–slip action, and concrete compressive strength on the performance of concrete beams when reinforced

  1. Health monitoring of precast bridge deck panels reinforced with glass fiber reinforced polymer (GFRP) bars.

    Science.gov (United States)

    2012-03-01

    The present research project investigates monitoring concrete precast panels for bridge decks that are reinforced with Glass Fiber Reinforced Polymer (GFRP) bars. Due to the lack of long term research on concrete members reinforced with GFRP bars, lo...

  2. Some Aspects of Ring Theory

    CERN Document Server

    Herstein, IN

    2011-01-01

    S. Amitsur: Associative rings with identities.- I.N. Herstein: Topics in ring theory.- N. Jacobson: Representation theory of Jordan algebras.- I. Kaplansky: The theory of homological dimension.- D. Buchsbaum: Complexes in local ring theory.- P.H. Cohn: Two topics in ring theory.- A.W. Goldie: Non-commutative localisation.

  3. Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes

    Directory of Open Access Journals (Sweden)

    Oleksandr Makeyev

    2016-06-01

    Full Text Available Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1-polar electrode with n rings using the (4n + 1-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2 and quadripolar (n = 3 electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected.

  4. Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes

    Science.gov (United States)

    Makeyev, Oleksandr; Besio, Walter G.

    2016-01-01

    Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected. PMID:27294933

  5. Caregiver preference for reinforcement-based interventions for problem behavior maintained by positive reinforcement.

    Science.gov (United States)

    Gabor, Anne M; Fritz, Jennifer N; Roath, Christopher T; Rothe, Brittany R; Gourley, Denise A

    2016-06-01

    Social validity of behavioral interventions typically is assessed with indirect methods or by determining preferences of the individuals who receive treatment, and direct observation of caregiver preference rarely is described. In this study, preferences of 5 caregivers were determined via a concurrent-chains procedure. Caregivers were neurotypical, and children had been diagnosed with developmental disabilities and engaged in problem behavior maintained by positive reinforcement. Caregivers were taught to implement noncontingent reinforcement (NCR), differential reinforcement of alternative behavior (DRA), and differential reinforcement of other behavior (DRO), and the caregivers selected interventions to implement during sessions with the child after they had demonstrated proficiency in implementing the interventions. Three caregivers preferred DRA, 1 caregiver preferred differential reinforcement procedures, and 1 caregiver did not exhibit a preference. Direct observation of implementation in concurrent-chains procedures may allow the identification of interventions that are implemented with sufficient integrity and preferred by caregivers. © 2016 Society for the Experimental Analysis of Behavior.

  6. Radar imaging of Saturn's rings

    Science.gov (United States)

    Nicholson, Philip D.; French, Richard G.; Campbell, Donald B.; Margot, Jean-Luc; Nolan, Michael C.; Black, Gregory J.; Salo, Heikki J.

    2005-09-01

    We present delay-Doppler images of Saturn's rings based on radar observations made at Arecibo Observatory between 1999 and 2003, at a wavelength of 12.6 cm and at ring opening angles of 20.1°⩽|B|⩽26.7°. The average radar cross-section of the A ring is ˜77% relative to that of the B ring, while a stringent upper limit of 3% is placed on the cross-section of the C ring and 9% on that of the Cassini Division. These results are consistent with those obtained by Ostro et al. [1982, Icarus 49, 367-381] from radar observations at |B|=21.4°, but provide higher resolution maps of the rings' reflectivity profile. The average cross-section of the A and B rings, normalized by their projected unblocked area, is found to have decreased from 1.25±0.31 to 0.74±0.19 as the rings have opened up, while the circular polarization ratio has increased from 0.64±0.06 to 0.77±0.06. The steep decrease in cross-section is at variance with previous radar measurements [Ostro et al., 1980, Icarus 41, 381-388], and neither this nor the polarization variations are easily understood within the framework of either classical, many-particle-thick or monolayer ring models. One possible explanation involves vertical size segregation in the rings, whereby observations at larger elevation angles which see deeper into the rings preferentially see the larger particles concentrated near the rings' mid-plane. These larger particles may be less reflective and/or rougher and thus more depolarizing than the smaller ones. Images from all four years show a strong m=2 azimuthal asymmetry in the reflectivity of the A ring, with an amplitude of ±20% and minima at longitudes of 67±4° and 247±4° from the sub-Earth point. We attribute the asymmetry to the presence of gravitational wakes in the A ring as invoked by Colombo et al. [1976, Nature 264, 344-345] to explain the similar asymmetry long seen at optical wavelengths. A simple radiative transfer model suggests that the enhancement of the azimuthal

  7. Study of improvement in 1st ring`s gas-seal; Top ring no gas seal seino kojo no kento

    Energy Technology Data Exchange (ETDEWEB)

    Ando, H; Tateishi, Y; Fujimura, K; Hitosugi, H [Nippon Piston Ring Co. Ltd., Tokyo (Japan)

    1997-10-01

    The authors studied the effect of an angle of 1st ring twist on the amount of blow-by concerning higher speed/higher output engines for motorcycles. As a result, the authors found the twist made the ring restrained in a ring groove of piston , and confirmed its suitable range for blow-by. By means of the developed optimization method, the authors have achieved significant reduction in blow-by at high engine speed. 1 ref., 9 figs., 2 tabs.

  8. Effects of reinforcer magnitude on responding under differential-reinforcement-of-low-rate schedules of rats and pigeons.

    Science.gov (United States)

    Doughty, Adam H; Richards, Jerry B

    2002-07-01

    Experiment I investigated the effects of reinforcer magnitude on differential-reinforcement-of-low-rate (DRL) schedule performance in three phases. In Phase 1, two groups of rats (n = 6 and 5) responded under a DRI. 72-s schedule with reinforcer magnitudes of either 30 or 300 microl of water. After acquisition, the water amounts were reversed for each rat. In Phase 2, the effects of the same reinforcer magnitudes on DRL 18-s schedule performance were examined across conditions. In Phase 3, each rat responded unider a DR1. 18-s schedule in which the water amotnts alternated between 30 and 300 microl daily. Throughout each phase of Experiment 1, the larger reinforcer magnitude resulted in higher response rates and lower reinforcement rates. The peak of the interresponse-time distributions was at a lower value tinder the larger reinforcer magnitude. In Experiment 2, 3 pigeons responded under a DRL 20-s schedule in which reinforcer magnitude (1-s or 6-s access to grain) varied iron session to session. Higher response rates and lower reinforcement rates occurred tinder the longer hopper duration. These results demonstrate that larger reinforcer magnitudes engender less efficient DRL schedule performance in both rats and pigeons, and when reinforcer magnitude was held constant between sessions or was varied daily. The present results are consistent with previous research demonstrating a decrease in efficiency as a function of increased reinforcer magnituide tinder procedures that require a period of time without a specified response. These findings also support the claim that DRI. schedule performance is not governed solely by a timing process.

  9. Viscosity of ring polymer melts

    KAUST Repository

    Pasquino, Rossana

    2013-10-15

    We have measured the linear rheology of critically purified ring polyisoprenes, polystyrenes, and polyethyleneoxides of different molar masses. The ratio of the zero-shear viscosities of linear polymer melts η0,linear to their ring counterparts η0,ring at isofrictional conditions is discussed as a function of the number of entanglements Z. In the unentangled regime η0,linear/η 0,ring is virtually constant, consistent with the earlier data, atomistic simulations, and the theoretical expectation η0,linear/ η0,ring = 2. In the entanglement regime, the Z-dependence of ring viscosity is much weaker than that of linear polymers, in qualitative agreement with predictions from scaling theory and simulations. The power-law extracted from the available experimental data in the rather limited range 1 < Z < 20, η0,linear/η0,ring ∼ Z 1.2±0.3, is weaker than the scaling prediction (η0,linear/η0,ring ∼ Z 1.6±0.3) and the simulations (η0,linear/ η0,ring ∼ Z2.0±0.3). Nevertheless, the present collection of state-of-the-art experimental data unambiguously demonstrates that rings exhibit a universal trend clearly departing from that of their linear counterparts, and hence it represents a major step toward resolving a 30-year-old problem. © 2013 American Chemical Society.

  10. Viscosity of ring polymer melts

    KAUST Repository

    Pasquino, Rossana; Vasilakopoulos, Thodoris C.; Jeong, Youncheol; Lee, Hyojoon; Rogers, Simon A.; Sakellariou, Georgios; Allgaier, Jü rgen B.; Takano, Atsushi; Brá s, Ana Rita E; Chang, Taihyun; Gooß en, Sebastian; Pyckhout-Hintzen, Wim; Wischnewski, Andreas; Hadjichristidis, Nikolaos; Richter, Dieter R.; Rubinstein, Michael H.; Vlassopoulos, Dimitris

    2013-01-01

    We have measured the linear rheology of critically purified ring polyisoprenes, polystyrenes, and polyethyleneoxides of different molar masses. The ratio of the zero-shear viscosities of linear polymer melts η0,linear to their ring counterparts η0,ring at isofrictional conditions is discussed as a function of the number of entanglements Z. In the unentangled regime η0,linear/η 0,ring is virtually constant, consistent with the earlier data, atomistic simulations, and the theoretical expectation η0,linear/ η0,ring = 2. In the entanglement regime, the Z-dependence of ring viscosity is much weaker than that of linear polymers, in qualitative agreement with predictions from scaling theory and simulations. The power-law extracted from the available experimental data in the rather limited range 1 < Z < 20, η0,linear/η0,ring ∼ Z 1.2±0.3, is weaker than the scaling prediction (η0,linear/η0,ring ∼ Z 1.6±0.3) and the simulations (η0,linear/ η0,ring ∼ Z2.0±0.3). Nevertheless, the present collection of state-of-the-art experimental data unambiguously demonstrates that rings exhibit a universal trend clearly departing from that of their linear counterparts, and hence it represents a major step toward resolving a 30-year-old problem. © 2013 American Chemical Society.

  11. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study.

    Directory of Open Access Journals (Sweden)

    Feng Liu

    Full Text Available BACKGROUND: Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM total hips in simulators. METHODS: Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC wear test in simulators. RESULTS: The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3/MC and 0.89 ± 0.04 mm(3/MC (t = 48.43, p = 0.000. The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS: This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE: This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

  12. Short-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery.

    Science.gov (United States)

    Mohaddes, Maziar; Rolfson, Ola; Kärrholm, Johan

    2015-02-01

    The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were performed using a TM cup. We compared the risk of reoperation and re-revision for TM cups and the 2 other most frequently used cup designs in acetabular revisions reported to the SHAR. The hypothesis was that the performance of TM cups is as good as that of established designs in the short term. The study population consisted of 2,384 patients who underwent 2,460 revisions during the period 2006 through 2012. The most commonly used cup designs were the press-fit porous-coated cup (n = 870), the trabecular metal cup (n = 805), and the cemented all-polyethylene cup (n = 785). 54% of the patients were female, and the median age at index revision was 72 (19-95) years. Reoperation was defined as a second surgical intervention, and re-revision-meaning exchange or removal of the cup-was used as endpoint. The mean follow-up time was 3.3 (0-7) years. There were 215 reoperations, 132 of which were re-revisions. The unadjusted and adjusted risk of reoperation or re-revision was not significantly different for the TM cup and the other 2 cup designs. Our data support continued use of TM cups in acetabular revisions. Further follow-up is necessary to determine whether trabecular metal cups can reduce the re-revision rate in the long term, compared to the less costly porous press-fit and cemented designs.

  13. ring og refleksion

    DEFF Research Database (Denmark)

    Wahlgren, B.; Rattleff, Pernille; Høyrup, S.

    State of the art inden for forskning om læring på arbejdspladsen samt gennemgang af læringsteori og refleksionsbegrebet hos Dewey, Dreyfus, Schön, Argyris, Kolb, Jarvis, Mezirow og Brookfield. Afsluttes med diskussion af syntetiseret model for læring på arbejdspladsen.......State of the art inden for forskning om læring på arbejdspladsen samt gennemgang af læringsteori og refleksionsbegrebet hos Dewey, Dreyfus, Schön, Argyris, Kolb, Jarvis, Mezirow og Brookfield. Afsluttes med diskussion af syntetiseret model for læring på arbejdspladsen....

  14. Birth Control Ring

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Ring KidsHealth / For Teens / Birth Control Ring What's ...

  15. From coffee ring to spherulites ring of poly(ethylene oxide) film from drying droplet

    Science.gov (United States)

    Hu, Yinchun; Zhang, Xuerong; Qiu, Maibo; Wei, Yan; Zhou, Qiong; Huang, Di

    2018-03-01

    We discuss how the "spherulites ring" morphology and "coffee ring" profile of PEO film formed by the drying droplet at glass substrate with different heating rate. Upon increasing the heating rate of substrate, it is found that deposited PEO film from drying droplet shows the unusually observed "coffee ring" profile and "spherulites ring" morphology. The main mechanism for this phenomenon is proposed to be an enhanced Marangoni convection which is induced by the increased solute concentration gradient and reduced viscous force above 70 °C. A simple formation mechanism of the unusually observed "coffee ring" profile and "spherulites ring" morphology is proposed. These findings can be exploited to trace the center of Marangoni convection, with potential applications in designing the spherulite patterns of crystalline polymer films in ink-jet printing and self-assembly fields.

  16. Systematic Search for Rings around Kepler Planet Candidates: Constraints on Ring Size and Occurrence Rate

    Science.gov (United States)

    Aizawa, Masataka; Masuda, Kento; Kawahara, Hajime; Suto, Yasushi

    2018-05-01

    We perform a systematic search for rings around 168 Kepler planet candidates with sufficient signal-to-noise ratios that are selected from all of the short-cadence data. We fit ringed and ringless models to their light curves and compare the fitting results to search for the signatures of planetary rings. First, we identify 29 tentative systems, for which the ringed models exhibit statistically significant improvement over the ringless models. The light curves of those systems are individually examined, but we are not able to identify any candidate that indicates evidence for rings. In turn, we find several mechanisms of false positives that would produce ringlike signals, and the null detection enables us to place upper limits on the size of the rings. Furthermore, assuming the tidal alignment between axes of the planetary rings and orbits, we conclude that the occurrence rate of rings larger than twice the planetary radius is less than 15%. Even though the majority of our targets are short-period planets, our null detection provides statistical and quantitative constraints on largely uncertain theoretical models of the origin, formation, and evolution of planetary rings.

  17. The usage of carbon fiber reinforcement polymer and glass fiber reinforcement polymer for retrofit technology building

    Science.gov (United States)

    Tarigan, Johannes; Meka, Randi; Nursyamsi

    2018-03-01

    Fiber Reinforcement Polymer has been used as a material technology since the 1970s in Europe. Fiber Reinforcement Polymer can reinforce the structure externally, and used in many types of buildings like beams, columns, and slabs. It has high tensile strength. Fiber Reinforcement Polymer also has high rigidity and strength. The profile of Fiber Reinforcement Polymer is thin and light, installation is simple to conduct. One of Fiber Reinforcement Polymer material is Carbon Fiber Reinforcement Polymer and Glass Fiber Reinforcement Polymer. These materials is tested when it is installed on concrete cylinders, to obtain the comparison of compressive strength CFRP and GFRP. The dimension of concrete is diameter of 15 cm and height of 30 cm. It is amounted to 15 and divided into three groups. The test is performed until it collapsed to obtain maximum load. The results of research using CFRP and GFRP have shown the significant enhancement in compressive strength. CFRP can increase the compressive strength of 26.89%, and GFRP of 14.89%. For the comparison of two materials, CFRP is more strengthening than GFRP regarding increasing compressive strength. The usage of CFRP and GFRP can increase the loading capacity.

  18. Structure and dynamics of ringed galaxies

    International Nuclear Information System (INIS)

    Buta, R.J.

    1984-01-01

    In many spiral and SO galaxies, single or multiple ring structures are visible in the disk. These inner rings (r), outer rings (R), and nuclear rings (nr) were investigated by means of morphology, photometry, and spectroscopy in order to provide basic data on a long neglected phenomenon. The metric properties of each ring are investigated and found to correlate with the structure of the parent galaxy. When properly calibrated, inner rings in barred (SB) systems can be used as geometric extragalactic distance indicators to distances in excess of 100 Mpc. Other statistics are presented that confirm previous indications that the rings have preferred shapes, relative sizes, and orientations with respect to bars. A survey is made of the less homogeneous non-barred (SA) ringed systems, and the causes of the inhomogeneity are isolated. It is shown that rings can be identified in multiple-ring SA systems that are exactly analogous to those in barred spirals

  19. Reinforced concrete tomography

    International Nuclear Information System (INIS)

    Mariscotti, M.A.J.; Morixe, M.; Tarela, P.A.; Thieberger, P.

    1997-01-01

    In this paper we describe the technique of reinforced concrete tomography, its historical background, recent technological developments and main applications. Gamma radiation sensitive plates are imprinted with radiation going through the concrete sample under study, and then processed to reveal the presence of reinforcement and defects in the material density. The three dimensional reconstruction, or tomography, of the reinforcement out of a single gammagraphy is an original development alternative to conventional methods. Re-bar diameters and positions may be determined with an accuracy of ± 1 mm 0.5-1 cm, respectively. The non-destructive character of this technique makes it particularly attractive in cases of inhabited buildings and diagnoses of balconies. (author) [es

  20. Multiplicative Structure and Hecke Rings of Generator Matrices for Codes over Quotient Rings of Euclidean Domains

    Directory of Open Access Journals (Sweden)

    Hajime Matsui

    2017-12-01

    Full Text Available In this study, we consider codes over Euclidean domains modulo their ideals. In the first half of the study, we deal with arbitrary Euclidean domains. We show that the product of generator matrices of codes over the rings mod a and mod b produces generator matrices of all codes over the ring mod a b , i.e., this correspondence is onto. Moreover, we show that if a and b are coprime, then this correspondence is one-to-one, i.e., there exist unique codes over the rings mod a and mod b that produce any given code over the ring mod a b through the product of their generator matrices. In the second half of the study, we focus on the typical Euclidean domains such as the rational integer ring, one-variable polynomial rings, rings of Gaussian and Eisenstein integers, p-adic integer rings and rings of one-variable formal power series. We define the reduced generator matrices of codes over Euclidean domains modulo their ideals and show their uniqueness. Finally, we apply our theory of reduced generator matrices to the Hecke rings of matrices over these Euclidean domains.

  1. Binomial Rings: Axiomatisation, Transfer and Classification

    OpenAIRE

    Xantcha, Qimh Richey

    2011-01-01

    Hall's binomial rings, rings with binomial coefficients, are given an axiomatisation and proved identical to the numerical rings studied by Ekedahl. The Binomial Transfer Principle is established, enabling combinatorial proofs of algebraical identities. The finitely generated binomial rings are completely classified. An application to modules over binomial rings is given.

  2. AN N-BODY INTEGRATOR FOR GRAVITATING PLANETARY RINGS, AND THE OUTER EDGE OF SATURN'S B RING

    International Nuclear Information System (INIS)

    Hahn, Joseph M.; Spitale, Joseph N.

    2013-01-01

    A new symplectic N-body integrator is introduced, one designed to calculate the global 360° evolution of a self-gravitating planetary ring that is in orbit about an oblate planet. This freely available code is called epi i nt, and it is distinct from other such codes in its use of streamlines to calculate the effects of ring self-gravity. The great advantage of this approach is that the perturbing forces arise from smooth wires of ring matter rather than discreet particles, so there is very little gravitational scattering and so only a modest number of particles are needed to simulate, say, the scalloped edge of a resonantly confined ring or the propagation of spiral density waves. The code is applied to the outer edge of Saturn's B ring, and a comparison of Cassini measurements of the ring's forced response to simulations of Mimas's resonant perturbations reveals that the B ring's surface density at its outer edge is σ 0 = 195 ± 60 g cm –2 , which, if the same everywhere across the ring, would mean that the B ring's mass is about 90% of Mimas's mass. Cassini observations show that the B ring-edge has several free normal modes, which are long-lived disturbances of the ring-edge that are not driven by any known satellite resonances. Although the mechanism that excites or sustains these normal modes is unknown, we can plant such a disturbance at a simulated ring's edge and find that these modes persist without any damping for more than ∼10 5 orbits or ∼100 yr despite the simulated ring's viscosity ν s = 100 cm 2 s –1 . These simulations also indicate that impulsive disturbances at a ring can excite long-lived normal modes, which suggests that an impact in the recent past by perhaps a cloud of cometary debris might have excited these disturbances, which are quite common to many of Saturn's sharp-edged rings

  3. Prediction of reinforcement corrosion using corrosion induced cracks width in corroded reinforced concrete beams

    International Nuclear Information System (INIS)

    Khan, Inamullah; François, Raoul; Castel, Arnaud

    2014-01-01

    This paper studies the evolution of reinforcement corrosion in comparison to corrosion crack width in a highly corroded reinforced concrete beam. Cracking and corrosion maps of the beam were drawn and steel reinforcement was recovered from the beam to observe the corrosion pattern and to measure the loss of mass of steel reinforcement. Maximum steel cross-section loss of the main reinforcement and average steel cross-section loss between stirrups were plotted against the crack width. The experimental results were compared with existing models proposed by Rodriguez et al., Vidal et al. and Zhang et al. Time prediction models for a given opening threshold are also compared to experimental results. Steel cross-section loss for stirrups was also measured and was plotted against the crack width. It was observed that steel cross-section loss in the stirrups had no relationship with the crack width of longitudinal corrosion cracks. -- Highlights: •Relationship between crack and corrosion of reinforcement was investigated. •Corrosion results of natural process and then corresponds to in-situ conditions. •Comparison with time predicting model is provided. •Prediction of load-bearing capacity from crack pattern was studied

  4. Study of the internal confinement of concrete reinforced (in civil engineering) with woven reinforcement

    Science.gov (United States)

    Dalal, M.; Goumairi, O.; El Malik, A.

    2017-10-01

    Concrete is generally the most used material in the field of construction. Despite its extensive use in structures, it represents some drawbacks related to its properties including its low tensile strength and low ductility. To solve this problem, the use of steel reinforcement in concrete structures is possible. Another possibility is the introduction of different types of continuous fibre / staple in the concrete, such as steel fibres or synthetic fibres, to obtain ″Concretes bundles″. Many types of fibre concrete, which have been developed and for many of them, the gain provided by the fibre was rather low and no significant improvement in tensile strength was really reaching. By cons, the ductility was higher than that of ordinary concrete. The objective of this study is to examine concrete reinforcement by inserting reinforcements woven polyester. These are either woven bidirectional (2D) or three-dimensional woven (3D). So we will report the properties of each type of reinforcement and the influence of the method of weaving on the strength reinforcements and on the strength of concrete in which they are incorporated. Such influence should contribute to improving the sustainability and enhancement of reinforcement

  5. Press fit shape femoral heads for acetabular reconstruction - 5 to 8 years results

    International Nuclear Information System (INIS)

    Obenous, C.; Girtler, R.; Schwoger, W.; Winkler, H.

    1999-01-01

    Filling of acetabular defects with allograft bone is a favourable method in revision-THR provided that primary stability and load bearing capability can be achieved. Since 1990 we perform structural allografting in the acetabular area using a special technique. Defects are prepared with hemispherical reamers (male) in order to obtain a smooth concave surface. Deep-frozen femoral heads are then prepared using female shapers of a diameter 0-4mm larger, thus obtaining a convex surface fitting precisely into the prepared bed. In ideal cases a press-fit can be obtained granting primary stability without additional implants, otherwise we secure the grafts against rotation with one or two traction screws in loading-direction. Implantation of the cup is performed like in primary THR, care is taken to place the implant exactly at the anatomically correct position. Weight bearing is performed as soon as after primary THR; due to the technique loads are distributed evenly over the entire contact area to host bone, pressing the graft firmly into its bed. From 1990 to 1993 this method has been used in 179 cases. 104 cases could be followed between 60 and 95 months (average 71,5 months). Mean age at operation was 66,5 years (39-87 vears). Defects were classified according to Gross as cavitary in 15, minor column in 50 and major column in 39 cases. 85x the cup has been cemented, 19x cementless. One uncemented and 7 cemented cups loosened, all within the first 2 years. 6 meanwhile have been revised a second time. Those usually were cases, where the cup was placed in a non-anatomical position and / or the graft was not secured against rotatory forces. In 17 cases we observed slight condensation of the grafts with consequent migration of the implants. Migration usually did not exceed 5mm and no other signs of implant loosening have been associated. Radiographs indicated a unifon-n pattern of rapid graft-incorporation. Remodelling seemed to be completed after the second year, from

  6. Galactic rings revisited - I. CVRHS classifications of 3962 ringed galaxies from the Galaxy Zoo 2 Database

    Science.gov (United States)

    Buta, Ronald J.

    2017-11-01

    Rings are important and characteristic features of disc-shaped galaxies. This paper is the first in a series that re-visits galactic rings with the goals of further understanding the nature of the features and for examining their role in the secular evolution of galaxy structure. The series begins with a new sample of 3962 galaxies drawn from the Galaxy Zoo 2 citizen science data base, selected because zoo volunteers recognized a ring-shaped pattern in the morphology as seen in Sloan Digital Sky Survey colour images. The galaxies are classified within the framework of the Comprehensive de Vaucouleurs revised Hubble-Sandage system. It is found that zoo volunteers cued on the same kinds of ring-like features that were recognized in the 1995 Catalogue of Southern Ringed Galaxies. This paper presents the full catalogue of morphological classifications, comparisons with other sources of classifications and some histograms designed mainly to highlight the content of the catalogue. The advantages of the sample are its large size and the generally good quality of the images; the main disadvantage is the low physical resolution that limits the detectability of linearly small rings such as nuclear rings. The catalogue includes mainly inner and outer disc rings and lenses. Cataclysmic (`encounter-driven') rings (such as ring and polar ring galaxies) are recognized in less than 1 per cent of the sample.

  7. Quantum Fourier Transform Over Galois Rings

    OpenAIRE

    Zhang, Yong

    2009-01-01

    Galois rings are regarded as "building blocks" of a finite commutative ring with identity. There have been many papers on classical error correction codes over Galois rings published. As an important warm-up before exploring quantum algorithms and quantum error correction codes over Galois rings, we study the quantum Fourier transform (QFT) over Galois rings and prove it can be efficiently preformed on a quantum computer. The properties of the QFT over Galois rings lead to the quantum algorit...

  8. Novel manifestations of the Aharonov-Bohm effect in quantum rings and Moebius rings

    International Nuclear Information System (INIS)

    Fomin, Vladimir M.

    2013-01-01

    - An overview is given on the recent experimental and theoretical advancements in studies of novel manifestations of the Aharonov-Bohm quantum-interference effect for excitons confined to self assembled quantum rings and other semiconductor nanostructures with ring-like states of charge carriers as well as for electrons in Moebius rings at the micro- and nanoscale. The exciton Aharonov-Bohm effect can be effectively controlled by an out-of-plane magnetic field, a vertical electric field, a spin disorder. A 'delocalization-to-localization' transition for the electron ground state occurs in a Moebius ring as it is made more inhomogeneous. (authors)

  9. Ring closure in actin polymers

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Supurna, E-mail: supurna@rri.res.in [Raman Research Institute, Bangalore 560080 (India); Chattopadhyay, Sebanti [Doon University, Dehradun 248001 (India)

    2017-03-18

    We present an analysis for the ring closure probability of semiflexible polymers within the pure bend Worm Like Chain (WLC) model. The ring closure probability predicted from our analysis can be tested against fluorescent actin cyclization experiments. We also discuss the effect of ring closure on bend angle fluctuations in actin polymers. - Highlights: • Ring closure of biopolymers. • Worm like chain model. • Predictions for experiments.

  10. On P-coherent endomorphism rings

    Indian Academy of Sciences (India)

    A ring is called right -coherent if every principal right ideal is finitely presented. Let M R be a right -module. We study the -coherence of the endomorphism ring of M R . It is shown that is a right -coherent ring if and only if every endomorphism of M R has a pseudokernel in add M R ; S is a left -coherent ring if and ...

  11. The Reinforcing Event (RE) Menu

    Science.gov (United States)

    Addison, Roger M.; Homme, Lloyd E.

    1973-01-01

    A motivational system, the Contingency Management System, uses contracts in which some amount of defined task behavior is demanded for some interval of reinforcing event. The Reinforcing Event Menu, a list of high probability reinforcing behaviors, is used in the system as a prompting device for the learner and as an aid for the administrator in…

  12. Acetabular anteversion is associated with gluteal tendinopathy at MRI

    Energy Technology Data Exchange (ETDEWEB)

    Moulton, Kyle M. [University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada); Royal University Hospital, Department of Medical Imaging, Saskatoon, SK (Canada); Aly, Abdel-Rahman [University of Saskatchewan, Department of Physical Medicine and Rehabilitation, Saskatoon, SK (Canada); Rajasekaran, Sathish [Health Pointe - Pain, Spine and Sport Medicine, Edmonton, AB (Canada); Shepel, Michael; Obaid, Haron [University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada)

    2015-01-15

    Gluteal tendinopathy and greater trochanteric pain syndrome (GTPS) remain incompletely understood despite their pervasiveness in clinical practice. To date, no study has analyzed the morphometric characteristics of the hip on magnetic resonance imaging (MRI) that may predispose to gluteal tendinopathy. This study aimed to evaluate whether acetabular anteversion (AA), femoral neck anteversion (FNA), and femoral neck-shaft angle (FNSA) are associated with MRI features of gluteal tendinopathy. A total of 203 MRI examinations of the hip met our inclusion and exclusion criteria. A single blinded investigator measured AA, FNA, and FNSA according to validated MRI techniques. Two blinded subspecialty-trained musculoskeletal radiologists then independently evaluated the presence of gluteal tendinosis, trochanteric bursitis, and subgluteal bursitis. Statistical analysis was performed using a one-way analysis of variance (ANOVA; post-hoc Tukey's range test). At MRI, 57 patients had gluteal tendinosis with or without bursitis, 26 had isolated trochanteric bursitis, and 11 had isolated subgluteal bursitis. AA was significantly (p = 0.01) increased in patients with MRI evidence of gluteal tendinosis with or without bursitis [mean: 18.4 , 95 % confidence interval (CI): 17.2 -19.6 ] compared with normal controls (mean: 15.7 , 95 % CI: 14.7 -16.8 ). Similarly, AA was significantly (p = 0.04) increased in patients with isolated trochanteric bursitis (mean: 18.8 , 95 % CI: 16.2 -21.6 ). No association was found between FNA or FNSA and the presence of gluteal tendinopathy. Interobserver agreement for the presence and categorization of gluteal tendinopathy was very good (kappa = 0.859, 95 % CI: 0.815-0.903). Our MRI study suggests that there is an association between increased AA and gluteal tendinopathy, which supports a growing body of evidence implicating abnormal biomechanics in the development of this condition. (orig.)

  13. Acetabular anteversion is associated with gluteal tendinopathy at MRI

    International Nuclear Information System (INIS)

    Moulton, Kyle M.; Aly, Abdel-Rahman; Rajasekaran, Sathish; Shepel, Michael; Obaid, Haron

    2015-01-01

    Gluteal tendinopathy and greater trochanteric pain syndrome (GTPS) remain incompletely understood despite their pervasiveness in clinical practice. To date, no study has analyzed the morphometric characteristics of the hip on magnetic resonance imaging (MRI) that may predispose to gluteal tendinopathy. This study aimed to evaluate whether acetabular anteversion (AA), femoral neck anteversion (FNA), and femoral neck-shaft angle (FNSA) are associated with MRI features of gluteal tendinopathy. A total of 203 MRI examinations of the hip met our inclusion and exclusion criteria. A single blinded investigator measured AA, FNA, and FNSA according to validated MRI techniques. Two blinded subspecialty-trained musculoskeletal radiologists then independently evaluated the presence of gluteal tendinosis, trochanteric bursitis, and subgluteal bursitis. Statistical analysis was performed using a one-way analysis of variance (ANOVA; post-hoc Tukey's range test). At MRI, 57 patients had gluteal tendinosis with or without bursitis, 26 had isolated trochanteric bursitis, and 11 had isolated subgluteal bursitis. AA was significantly (p = 0.01) increased in patients with MRI evidence of gluteal tendinosis with or without bursitis [mean: 18.4 , 95 % confidence interval (CI): 17.2 -19.6 ] compared with normal controls (mean: 15.7 , 95 % CI: 14.7 -16.8 ). Similarly, AA was significantly (p = 0.04) increased in patients with isolated trochanteric bursitis (mean: 18.8 , 95 % CI: 16.2 -21.6 ). No association was found between FNA or FNSA and the presence of gluteal tendinopathy. Interobserver agreement for the presence and categorization of gluteal tendinopathy was very good (kappa = 0.859, 95 % CI: 0.815-0.903). Our MRI study suggests that there is an association between increased AA and gluteal tendinopathy, which supports a growing body of evidence implicating abnormal biomechanics in the development of this condition. (orig.)

  14. Faithfully quadratic rings

    CERN Document Server

    Dickmann, M

    2015-01-01

    In this monograph the authors extend the classical algebraic theory of quadratic forms over fields to diagonal quadratic forms with invertible entries over broad classes of commutative, unitary rings where -1 is not a sum of squares and 2 is invertible. They accomplish this by: (1) Extending the classical notion of matrix isometry of forms to a suitable notion of T-isometry, where T is a preorder of the given ring, A, or T = A^2. (2) Introducing in this context three axioms expressing simple properties of (value) representation of elements of the ring by quadratic forms, well-known to hold in

  15. BERKELEY: ALS ring

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1993-06-15

    Everybody at Lawrence Berkeley Laboratory's Center for Beam Physics is pleased with the rapid progress in commissioning LBL's Advanced Light Source (ALS) electron storage ring, the foundation for this third-generation synchrotron radiation facility. Designed for a maximum current of 400 mA, the ALS storage ring reached 407 mA just 24 days after storing the first beam on 16 March. ALS construction as a US Department of Energy (DOE) national user facility to provide high-brightness vacuum ultra-violet and soft x-ray radiation began in October 1987. One technical requirement marking project completion was to accumulate a 50-mA current in the storage ring. The ALS passed this milestone on 24 March, a week ahead of the official deadline. Once injected, the electron beam decays quasi-exponentially primarily because of interactions with residual gas molecules in the storage-ring vacuum chamber. Eventually, when the pressure in the vacuum chamber with beam decreases toward the expected operating level of 1 nano Torr, it will only be necessary to refill the storage ring at intervals of four to eight hours. At present the vacuum is improving rapidly as surfaces are irradiated (scrubbed) by the synchrotron radiation itself. At 100 mA, beam lifetime was about one hour (9 April)

  16. Compressible Vortex Ring

    Science.gov (United States)

    Elavarasan, Ramasamy; Arakeri, Jayawant; Krothapalli, Anjaneyulu

    1999-11-01

    The interaction of a high-speed vortex ring with a shock wave is one of the fundamental issues as it is a source of sound in supersonic jets. The complex flow field induced by the vortex alters the propagation of the shock wave greatly. In order to understand the process, a compressible vortex ring is studied in detail using Particle Image Velocimetry (PIV) and shadowgraphic techniques. The high-speed vortex ring is generated from a shock tube and the shock wave, which precedes the vortex, is reflected back by a plate and made to interact with the vortex. The shadowgraph images indicate that the reflected shock front is influenced by the non-uniform flow induced by the vortex and is decelerated while passing through the vortex. It appears that after the interaction the shock is "split" into two. The PIV measurements provided clear picture about the evolution of the vortex at different time interval. The centerline velocity traces show the maximum velocity to be around 350 m/s. The velocity field, unlike in incompressible rings, contains contributions from both the shock and the vortex ring. The velocity distribution across the vortex core, core diameter and circulation are also calculated from the PIV data.

  17. BERKELEY: ALS ring

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Everybody at Lawrence Berkeley Laboratory's Center for Beam Physics is pleased with the rapid progress in commissioning LBL's Advanced Light Source (ALS) electron storage ring, the foundation for this third-generation synchrotron radiation facility. Designed for a maximum current of 400 mA, the ALS storage ring reached 407 mA just 24 days after storing the first beam on 16 March. ALS construction as a US Department of Energy (DOE) national user facility to provide high-brightness vacuum ultra-violet and soft x-ray radiation began in October 1987. One technical requirement marking project completion was to accumulate a 50-mA current in the storage ring. The ALS passed this milestone on 24 March, a week ahead of the official deadline. Once injected, the electron beam decays quasi-exponentially primarily because of interactions with residual gas molecules in the storage-ring vacuum chamber. Eventually, when the pressure in the vacuum chamber with beam decreases toward the expected operating level of 1 nano Torr, it will only be necessary to refill the storage ring at intervals of four to eight hours. At present the vacuum is improving rapidly as surfaces are irradiated (scrubbed) by the synchrotron radiation itself. At 100 mA, beam lifetime was about one hour (9 April)

  18. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    Science.gov (United States)

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of step of step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as measured on CT scans are both related to long-term hip survivorship, but step displacement (1 mm) is tolerated less than gap displacement (5 mm). Of the 2 types of displacement, only a large gap displacement (≥5 mm) was independently associated with conversion to total hip arthroplasty. In younger patients who had less articular impaction with smaller residual

  19. Accidental ingestion of BiTine ring and a note on inefficient ring separation forceps

    Directory of Open Access Journals (Sweden)

    Baghele ON

    2011-05-01

    Full Text Available Om Nemichand Baghele1, Mangala Om Baghele21Department of Periodontology, SMBT Dental College and Hospital, Sangamner, Ahmednagar, Maharashtra, India; 2Private General Dental Practice, Mumbai, IndiaBackground: Accidental ingestion of medium-to-large instruments is relatively uncommon during dental treatment but can be potentially dangerous. A case of BiTine ring ingestion is presented with a note on inefficient ring separation forceps.Case description: A 28-year-old male patient accidentally ingested the BiTine ring (2 cm diameter, 0.5 cm outward projections while it was being applied to a distoproximal cavity in tooth # 19. The ring placement forceps were excessively flexible; bending of the beaks towards the ring combined with a poor no-slippage mechanism led to sudden disengagement of the ring and accelerated movement towards the pharynx. We followed the patient with bulk forming agents and radiographs. Fortunately the ring passed out without any complications.Clinical implications: Checking equipment and methods is as important as taking precautions against any preventable medical emergency. It is the responsibility of the clinician to check, verify and then use any instrument/equipment.Keywords: foreign bodies/radiography, foreign bodies/complications, equipment failure, dental instrument, accidental ingestion

  20. Steel fiber reinforced concrete

    International Nuclear Information System (INIS)

    Baloch, S.U.

    2005-01-01

    Steel-Fiber Reinforced Concrete is constructed by adding short fibers of small cross-sectional size .to the fresh concrete. These fibers reinforce the concrete in all directions, as they are randomly oriented. The improved mechanical properties of concrete include ductility, impact-resistance, compressive, tensile and flexural strength and abrasion-resistance. These uniqlte properties of the fiber- reinforcement can be exploited to great advantage in concrete structural members containing both conventional bar-reinforcement and steel fibers. The improvements in mechanical properties of cementitious materials resulting from steel-fiber reinforcement depend on the type, geometry, volume fraction and material-properties of fibers, the matrix mix proportions and the fiber-matrix interfacial bond characteristics. Effects of steel fibers on the mechanical properties of concrete have been investigated in this paper through a comprehensive testing-programme, by varying the fiber volume fraction and the aspect-ratio (Lid) of fibers. Significant improvements are observed in compressive, tensile, flexural strength and impact-resistance of concrete, accompanied by marked improvement in ductility. optimum fiber-volume fraction and aspect-ratio of steel fibers is identified. Test results are analyzed in details and relevant conclusions drawn. The research is finally concluded with future research needs. (author)

  1. On the Laurent polynomial rings

    International Nuclear Information System (INIS)

    Stefanescu, D.

    1985-02-01

    We describe some properties of the Laurent polynomial rings in a finite number of indeterminates over a commutative unitary ring. We study some subrings of the Laurent polynomial rings. We finally obtain two cancellation properties. (author)

  2. Corrosion of reinforcement bars in steel ibre reinforced concrete structures

    DEFF Research Database (Denmark)

    Solgaard, Anders Ole Stubbe

    and the influence of steel fibres on initiation and propagation of cracks in concrete. Moreover, the impact of fibres on corrosion-induced cover cracking was covered. The impact of steel fibres on propagation of reinforcement corrosion was investigated through studies of their impact on the electrical resistivity...... of concrete, which is known to affect the corrosion process of embedded reinforcement. The work concerning the impact of steel fibres on initiation and propagation of cracks was linked to corrosion initiation and propagation of embedded reinforcement bars via additional studies. Cracks in the concrete cover...... are known to alter the ingress rate of depassivating substances and thereby influence the corrosion process. The Ph.D. study covered numerical as well as experimental studies. Electrochemically passive steel fibres are electrically isolating thus not changing the electrical resistivity of concrete, whereas...

  3. The Hi-Ring DCN Architecture

    DEFF Research Database (Denmark)

    Galili, Michael; Kamchevska, Valerija; Ding, Yunhong

    2016-01-01

    We will review recent work on the proposed hierarchical ring-based architecture (HiRing) proposed for data center networks. We will discuss the architecture and initial demonstrations of optical switching performance and time-domain synchronization......We will review recent work on the proposed hierarchical ring-based architecture (HiRing) proposed for data center networks. We will discuss the architecture and initial demonstrations of optical switching performance and time-domain synchronization...

  4. Hip Arthroscopy for Femoral-Acetabular Impingement: Do Active Claims Affect Outcomes?

    Science.gov (United States)

    Gigi, Roy; Rath, Ehud; Sharfman, Zachary T; Shimonovich, Shachar; Ronen, Itai; Amar, Eyal

    2016-04-01

    To compare outcomes of 3 patient groups undergoing hip arthroscopy. This study included 138 consecutive hip arthroscopies (106 analyzed) for femoral-acetabular impingement (FAI) with or without labral tear in patients with a minimum 1-year follow-up. Inclusion criteria included patients older than 18 with clinical or radiologic manifestation of FAI with or without labral tear. Exclusion criteria included previous hip surgery and various hip pathologies. Patients were classified into 3 study groups. Group 1 included work-related injuries with active claims ACs (n = 33); mean age, 32 (range, 19 to 63); group 2 included sports injuries with no ACs (n = 35); mean age, 32 (range, 18 to 69); and group 3 included non-sports-related injuries without pending ACs (NAS; n = 38); mean age, 45 (range, 20 to 68). Outcomes were assessed using modified Harris hip scores (mHHS) and hip outcome scores (HOS) preoperatively and during the final evaluation. Baseline score for all groups did not significantly differ (P = .210 for mHHS, P = .176 for HOS). All groups significantly improved from preoperative to final evaluation (group 1: mHHS P = .42, HOS P = .001; group 2: mHHS P arthroscopy. Hip arthroscopy as an intervention in patients with ACs provided positive outcomes, corroborating that an AC is not a contraindication for this procedure. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. EBT ring physics

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1980-04-01

    This workshop attempted to evaluate the status of the current experimental and theoretical understanding of hot electron ring properties. The dominant physical processes that influence ring formation, scaling, and their optimal behavior are also studied. Separate abstracts were prepared for each of the 27 included papers

  6. Algorithms for Reinforcement Learning

    CERN Document Server

    Szepesvari, Csaba

    2010-01-01

    Reinforcement learning is a learning paradigm concerned with learning to control a system so as to maximize a numerical performance measure that expresses a long-term objective. What distinguishes reinforcement learning from supervised learning is that only partial feedback is given to the learner about the learner's predictions. Further, the predictions may have long term effects through influencing the future state of the controlled system. Thus, time plays a special role. The goal in reinforcement learning is to develop efficient learning algorithms, as well as to understand the algorithms'

  7. Ground Movement in SSRL Ring

    International Nuclear Information System (INIS)

    Sunikumar, Nikita

    2011-01-01

    Users of the Stanford Synchrotron Radiation Lightsource (SSRL) are being affected by diurnal motion of the synchrotron's storage ring, which undergoes structural changes due to outdoor temperature fluctuations. In order to minimize the effects of diurnal temperature fluctuations, especially on the vertical motion of the ring floor, scientists at SSRL tried three approaches: painting the storage ring white, covering the asphalt in the middle of the ring with highly reflective Mylar and installing Mylar on a portion of the ring roof and walls. Vertical motion in the storage ring is measured by a Hydrostatic Leveling System (HLS), which calculates the relative height of water in a pipe that extends around the ring. The 24-hr amplitude of the floor motion was determined using spectral analysis of HLS data, and the ratio of this amplitude before and after each experiment was used to quantitatively determine the efficacy of each approach. The results of this analysis showed that the Mylar did not have any significant effect on floor motion, although the whitewash project did yield a reduction in overall HLS variation of 15 percent. However, further analysis showed that the reduction can largely be attributed to a few local changes rather than an overall reduction in floor motion around the ring. Future work will consist of identifying and selectively insulating these local regions in order to find the driving force behind diurnal floor motion in the storage ring.

  8. Token ring technology report

    CERN Document Server

    2013-01-01

    Please note this is a Short Discount publication. This report provides an overview of the IBM Token-Ring technology and products built by IBM and compatible vendors. It consists of two sections: 1. A summary of the design trade-offs for the IBM Token-Ring. 2. A summary of the products of the major token-ring compatible vendors broken down by adapters and components, wiring systems, testing, and new chip technology.

  9. BIOMECHANICAL JUSTIFICATION OF THE THREADED ELEMENT’S FORM OF THE TOTAL HIP ENDOPROSTHESIS’ ACETABULAR COMPONENT

    Directory of Open Access Journals (Sweden)

    PANCHENKO S. P.

    2017-03-01

    Full Text Available Abstract. Formulation of the problem. Total hip replacement (THR remains to be responsible for the markable clinical achievements of contemporal orthopaedic surgery [1; 2; 4]. It should be noted, that numerous efforts to create an “ideal” uncemented hip endoprosthesis’ construction were failed, but led into wide diversity of implants. Such a diversity allowes to individualize implant type selection and to improve implant’s survival and total THR’s clinical outcomes [1; 4]. Outcomes mentioned above determine successful application of total hip replacement as a treatment method. Consequently, development of new and improvement of existing hip endoprosthesis’ constructions seems to be of current interest for contemporal orthopaedic surgery. Purpose. To determine optimal parametres of threaded element’s geometry of total hip endoprosthesis’ threaded acetabular component. Conclusion. There were revealed that threaded element model with right-angled triangle transverse section shape seems to be the most effective considering hardness, while the triangle is leaned on the bone massive with its cathetus. At the same time, results of calculations represent pelvic bone stress-strain state during THR quantitavely and stipulate further research.

  10. Prototype moving-ring reactor

    International Nuclear Information System (INIS)

    Smith, A.C. Jr.; Ashworth, C.P.; Abreu, K.E.

    1982-01-01

    We have completed a design of the Prototype Moving-Ring Reactor. The fusion fuel is confined in current-carrying rings of magnetically-field-reversed plasma (Compact Toroids). The plasma rings, formed by a coaxial plasma gun, undergo adiabatic magnetic compression to ignition temperature while they are being injected into the reactor's burner section. The cylindrical burner chamber is divided into three burn stations. Separator coils and a slight axial guide field gradient are used to shuttle the ignited toroids rapidly from one burn station to the next, pausing for 1/3 of the total burn time at each station. D-T- 3 He ice pellets refuel the rings at a rate which maintains constant radiated power

  11. Continuous Reinforced Concrete Beams

    DEFF Research Database (Denmark)

    Hoang, Cao Linh; Nielsen, Mogens Peter

    1996-01-01

    This report deals with stress and stiffness estimates of continuous reinforced concrete beams with different stiffnesses for negative and positive moments e.g. corresponding to different reinforcement areas in top and bottom. Such conditions are often met in practice.The moment distribution...

  12. Polycomb Group Proteins RING1A and RING1B Regulate the Vegetative Phase Transition in Arabidopsis

    Directory of Open Access Journals (Sweden)

    Jian Li

    2017-05-01

    Full Text Available Polycomb group (PcG protein-mediated gene silencing is a major regulatory mechanism in higher eukaryotes that affects gene expression at the transcriptional level. Here, we report that two conserved homologous PcG proteins, RING1A and RING1B (RING1A/B, are required for global H2A monoubiquitination (H2Aub in Arabidopsis. The mutation of RING1A/B increased the expression of members of the SQUAMOSA PROMOTER BINDING PROTEIN-LIKE (SPL gene family and caused an early vegetative phase transition. The early vegetative phase transition observed in ring1a ring1b double mutant plants was dependent on an SPL family gene, and the H2Aub status of the chromatin at SPL locus was dependent on RING1A/B. Moreover, mutation in RING1A/B affected the miRNA156a-mediated vegetative phase transition, and RING1A/B and the AGO7-miR390-TAS3 pathway were found to additively regulate this transition in Arabidopsis. Together, our results demonstrate that RING1A/B regulates the vegetative phase transition in Arabidopsis through the repression of SPL family genes.

  13. Researches on the Piston Ring

    Science.gov (United States)

    Ehihara, Keikiti

    1944-01-01

    In internal combustion engines, steam engines, air compressors, and so forth, the piston ring plays an important role. Especially, the recent development of Diesel engines which require a high compression pressure for their working, makes, nowadays, the packing action of the piston ring far more important than ever. Though a number of papers have been published in regard to researches on the problem of the piston ring, none has yet dealt with an exact measurement of pressure exerted on the cylinder wall at any given point of the ring. The only paper that can be traced on this subject so far is Mr. Nakagawa's report on the determination of the relative distribution of pressure on the cylinder wall, but the measuring method adopted therein appears to need further consideration. No exact idea has yet been obtained as to how the obturation of gas between the piston and cylinder, the frictional resistance of the piston, and the wear of the cylinder wall are affected by the intensity and the distribution of the radial pressure of the piston ring. Consequently, the author has endeavored, by employing an apparatus of his own invention, to get an exact determination of the pressure distribution of the piston ring. By means of a newly devised ring tester, to which piezoelectricity of quartz was applied, the distribution of the radial pressure of many sample rings on the market was accurately determined. Since many famous piston rings show very irregular pressure distribution, the author investigated and achieved a manufacturing process of the piston ring which will exert uniform pressure on the cylinder wall. Temperature effects on the configuration and on the mean spring power have also been studied. Further, the tests were performed to ascertain how the gas tightness of the piston ring may be affected by the number or spring power. The researches as to the frictional resistance between the piston ring and the cylinder wall were carried out, too. The procedure of study, and

  14. Modelling reinforcement corrosion in concrete

    DEFF Research Database (Denmark)

    Michel, Alexander; Geiker, Mette Rica; Stang, Henrik

    2012-01-01

    A physio-chemical model for the simulation of reinforcement corrosion in concrete struc-tures was developed. The model allows for simulation of initiation and subsequent propaga-tion of reinforcement corrosion. Corrosion is assumed to be initiated once a defined critical chloride threshold......, a numerical example is pre-sented, that illustrates the formation of corrosion cells as well as propagation of corrosion in a reinforced concrete structure....

  15. The Reinforcement Learning Competition 2014

    OpenAIRE

    Dimitrakakis, Christos; Li, Guangliang; Tziortziotis, Nikoalos

    2014-01-01

    Reinforcement learning is one of the most general problems in artificial intelligence. It has been used to model problems in automated experiment design, control, economics, game playing, scheduling and telecommunications. The aim of the reinforcement learning competition is to encourage the development of very general learning agents for arbitrary reinforcement learning problems and to provide a test-bed for the unbiased evaluation of algorithms.

  16. Generation of stable mixed-compact-toroid rings by inducing plasma currents in strong E rings

    International Nuclear Information System (INIS)

    Jayakumar, R.; Taggart, D.P.; Parker, M.R.; Fleischmann, H.H.

    1989-01-01

    In the RECE-Christa device, hybrid-type compact toroid rings are generated by inducing large toroidal plasma currents I rho in strong electron rings using a thin induction coil positioned along the ring axis. Starting from field-reversal values δ ο = 50 - 120 percent of the original pure fast-electron ring, the induced plasma current I rho raises δ to a maximum value of up to 240 percent with I rho contributing more than 50 percent of the total ring current. Quite interestingly, the generated hybrid compact toroid configurations appear gross-stable during the full I rho pulse length (half-amplitude width about 100 μs)

  17. Magnetization of two coupled rings

    International Nuclear Information System (INIS)

    Avishai, Y; Luck, J M

    2009-01-01

    We investigate the persistent currents and magnetization of a mesoscopic system consisting of two clean metallic rings sharing a single contact point in a magnetic field. Many novel features with respect to the single-ring geometry are underlined, including the explicit dependence of wavefunctions on the Aharonov-Bohm fluxes, the complex pattern of two-fold and three-fold degeneracies, the key role of length and flux commensurability, and in the case of commensurate ring lengths the occurrence of idle levels which do not carry any current. Spin-orbit interactions, induced by the electric fields of charged wires threading the rings, give rise to a peculiar version of the Aharonov-Casher effect where, unlike for a single ring, spin is not conserved. Remarkably enough, this can only be realized when the Aharonov-Bohm fluxes in both rings are neither integer nor half-integer multiples of the flux quantum

  18. Determination of the buckling safety of reinforced concrete shells considering the nonlinear material-behavior

    International Nuclear Information System (INIS)

    Zerna, W.; Mungan, I.; Steffen, W.

    1980-01-01

    The equations of the bending and stability theories for the orthotropic shell are solved using the FEM. A biaxial material law for concrete and a nearly bilinear stress-strain diagram for reinforcing steel were considered. Taking a layered ring element the influence of bending moments together with the membrane forces can be followed under increasing load up to failure of concrete or steel. At each level the bucking factor can be calculated considering the stress dependent buckling stiffness. The method of calculation is applied to a cooling tower shell under dead load acting simultaneously with an axi-symmetric loading to compensate for the wind effect. Due to orthotropy and descending tangent modulus at the ultimate load the buckling load factor drops to the half of the value obtained assuming a linear elastic behaviour. Additional parametric studies demonstrate the effect of some hypothetic cracks of different position and depth of the bifurcation results. The variation of the safety factors against buckling and ultimate load is obtained by changing the shell thickness. For the shell investigated it turns out that the buckling safety is influenced much more than the safety against material failure if the wall thickness is varied. It is recommended to split the buckling analysis of reinforced concrete shells in two parts. For shells of parts of a shell under only slightly disturbed membrane stress state the buckling analysis governs, otherwise the ultimate state considering the geometric and material nonlinearities is decisive to obtain not only the wall thickness but also the amount of reinforced necessary. (orig./HP) [de

  19. Radioactive gold ring dermatitis

    International Nuclear Information System (INIS)

    Miller, R.A.; Aldrich, J.E.

    1990-01-01

    A superficial squamous cell carcinoma developed in a woman who wore a radioactive gold ring for more than 30 years. Only part of the ring was radioactive. Radiation dose measurements indicated that the dose to basal skin layer was 2.4 Gy (240 rad) per week. If it is assumed that the woman continually wore her wedding ring for 37 years since purchase, she would have received a maximum dose of approximately 4600 Gy

  20. Analytical model for double split ring resonators with arbitrary ring width

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Jensen, Thomas; Krozer, Viktor

    2008-01-01

    For the first time, the analytical model for a double split ring resonator with unequal width rings is developed. The proposed models for the resonators with equal and unequal widths are based on an impedance matrix representation and provide the prediction of performance in a wide frequency range...

  1. Pure subrings of the rings

    International Nuclear Information System (INIS)

    Tsarev, Andrei V

    2009-01-01

    Pure subrings of finite rank in the Z-adic completion of the ring of integers and in its homomorphic images are considered. Certain properties of these rings are studied (existence of an identity element, decomposability into a direct sum of essentially indecomposable ideals, condition for embeddability into a csp-ring, etc.). Additive groups of these rings and conditions under which these rings are subrings of algebraic number fields are described. Bibliography: 12 titles.

  2. Achados em ressonância magnética artrográfica de indivíduos com lesão do labrum acetabular Magnetic resonance arthrographic findings in subjects with acetabular labral tears

    Directory of Open Access Journals (Sweden)

    André Luiz Almeida Pizzolatti

    2011-01-01

    Full Text Available OBJETIVO: Descrever os achados em artro RM de sujeitos com suspeita de lesão do labrum acetabular. MÉTODO: Foram analisadas 108 artro RM de quadris em 2007/2008. Dois radiologistas independentemente analisaram as imagens e foi considerada a resposta comum entre eles. Com base em seus pareceres observou-se o local e estadiamento das lesões labrais e condrais, as alterações anatômicas, e a presença de tendinite e bursite trocantérica. RESULTADO: As lesões labrais grau I ocorreram em 41% dos casos, grau II em 31%, e grau III em 29%. O IFA tipo cam foi frequente em 36% dos casos, tipo pincer em 11%, e IFA misto em 13%, nestes casos 57% apresentaram lesão labral grau III, A lesão condral grau I foi observada em 51% acetábulos, as de grau II em 13%, e grau III em 18%. CONCLUSÃO: As alterações morfológicas que provocam IFA do tipo cam foram as mais prevalentes. Em relação ao grau de lesão labral e condral foram predominantes as lesões grau I independente da presença ou do tipo de IFA, exceto em IFAs mistos onde houve predomínio de lesão labral grau III. Não foi observada uma relação entre o grau de lesão labral e condral.OBJECTIVE: To describe the MR arthrographic findings in subjects with suspected acetabular labral tears of the hip. METHOD: 108 hip MRa results were analyzed in 2007-2008. Two radiologists independently interpreted the images, and the consensual answers between them were considered for analysis. Based on their opinions, information was obtained on the location, staging of the chondral and labral lesions, anatomic alterations, and the presence of trochanteric bursitis and tendonitis. RESULTS: 1st degree labral lesions occurred in 41% of cases, 2nd degree in 31%, and 3rd degree in 29%. The cam type FAI was common in 36% of cases, pincer FAI in 11%, and mixed cam-pincer FAI in 13%; in these cases 57% had grade III labral lesions. 1st degree chondral lesions were observed in 51% of acetabulum, 2nd degree in 13

  3. Origins of food reinforcement in infants12345

    Science.gov (United States)

    Kong, Kai Ling; Feda, Denise M; Eiden, Rina D; Epstein, Leonard H

    2015-01-01

    Background: Rapid weight gain in infancy is associated with a higher risk of obesity in children and adults. A high relative reinforcing value of food is cross-sectionally related to obesity; lean children find nonfood alternatives more reinforcing than do overweight/obese children. However, to our knowledge, there is no research on how and when food reinforcement develops. Objective: This study was designed to assess whether the reinforcing value of food and nonfood alternatives could be tested in 9- to 18-mo-old infants and whether the reinforcing value of food and nonfood alternatives is differentially related to infant weight status. Design: Reinforcing values were assessed by using absolute progressive ratio schedules of reinforcement, with presentation of food and nonfood alternatives counterbalanced in 2 separate studies. Two nonfood reinforcers [Baby Einstein–Baby MacDonald shows (study 1, n = 27) or bubbles (study 2, n = 30)] were tested against the baby’s favorite food. Food reinforcing ratio (FRR) was quantified by measuring the reinforcing value of food (Food Pmax) in proportion to the total reinforcing value of food and a nonfood alternative (DVD Pmax or BUB Pmax). Results: Greater weight-for-length z score was associated with a greater FRR of a favorite food in study 1 (FRR-DVD) (r = 0.60, P positively associated with FRR-DVD (r = 0.57, P = 0.009) and FRR-BUB (r = 0.37, P = 0.047). Conclusions: Our newly developed paradigm, which tested 2 different nonfood alternatives, demonstrated that lean infants find nonfood alternatives more reinforcing than do overweight/obese infants. This observation suggests that strengthening the alternative reinforcers may have a protective effect against childhood obesity. This research was registered at clinicaltrials.gov as NCT02229552. PMID:25733636

  4. Ring accelerators

    International Nuclear Information System (INIS)

    Gisler, G.; Faehl, R.

    1983-01-01

    We present two-dimensional simulations in (r-z) and r-theta) cylinderical geometries of imploding-liner-driven accelerators of rings of charged particles. We address issues of azimuthal and longitudinal stability of the rings. We discuss self-trapping designs in which beam injection and extraction is aided by means of external cusp fields. Our simulations are done with the 2-1/2-D particle-in-cell plasma simulation code CLINER, which combines collisionless, electromagnetic PIC capabilities with a quasi-MHD finite element package

  5. Manipulation of vortex rings for flow control

    International Nuclear Information System (INIS)

    Toyoda, Kuniaki; Hiramoto, Riho

    2009-01-01

    This paper reviews the dynamics of vortex rings and the control of flow by the manipulation of vortex rings. Vortex rings play key roles in many flows; hence, the understanding of the dynamics of vortex rings is crucial for scientists and engineers dealing with flow phenomena. We describe the structures and motions of vortex rings in circular and noncircular jets, which are typical examples of flows evolving into vortex rings. For circular jets the mechanism of evolving, merging and breakdown of vortex rings is described, and for noncircular jets the dynamics of three-dimensional deformation and interaction of noncircular vortex rings under the effect of self- and mutual induction is discussed. The application of vortex-ring manipulation to the control of various flows is reviewed with successful examples, based on the relationship between the vortex ring dynamics and the flow properties. (invited paper)

  6. The Rings of Saturn

    Science.gov (United States)

    Cuzzi, J. N.; Filacchione, G.; Marouf, E. A.

    2018-03-01

    One could become an expert on Saturn's iconic rings pretty easily in the early 1970s, as very little was known about them beyond the distinction between the A, B, and C rings, and the Cassini Division or "gap" between rings A and B (Alexander, 1962; Bobrov, 1970). Water ice was discovered spectroscopically on the ring particle surfaces, and radar and microwave emission observations proved that the particles must be centimeters to meters in size, consisting primarily, not just superficially, of water ice (Pollack, 1975). While a 2:1 orbital resonance with Mimas had long been suspected of having something to do with the Cassini Division, computers of the time were unable to model the subtle dynamical effects that we now know to dominate ring structure. This innocent state of affairs was exploded by the Voyager 1 and 2 encounters in 1980 and 1981. Spectacular images revealed filigree structure and odd regional color variations, and exquisitely detailed radial profiles of fluctuating particle abundance were obtained from the first stellar and radio occultations, having resolution almost at the scale of single particles. Voyager-era understanding was reviewed by Cuzzi et al. (1984) and Esposito et al. (1984). While the Voyager data kept ring scientists busy for decades, planning which led to the monumentally successful NASA-ESA-ASI Cassini mission, which arrived in 2004, had been under way even before Voyager got to Saturn. A review of pre-Cassini knowledge of Saturn's Rings can be found in Orton et al. (2009). This chapter will build on recent topical and process-specific reviews that treat the gamut of ring phenomena and its underlying physics in considerable detail (Colwell et al., 2009; Cuzzi et al., 2009; Horányi et al., 2009; Schmidt et al., 2009; Esposito, 2010; Tiscareno, 2013b; Esposito, 2014). We will follow and extend the general organization of Cuzzi et al. (2010), the most recent general discussion of Saturn's rings. For brevity and the benefit of the

  7. Examination techniques for non-magnetic rings

    International Nuclear Information System (INIS)

    Metala, M.J.; Kilpatrick, N.L.; Frank, W.W.

    1990-01-01

    Until the introduction of 18Mn18Cr rings a few years ago, most non-magnetic steel rings for generator rotors were made from 18Mn5Cr alloy steel, which is highly susceptible to stress corrosion cracking in the presence of water. This, the latest in a series of papers on the subject of non-magnetic rings by the authors' company, provides a discussion of nondestructive examination of 18Mn5Cr rings for stress corrosion distress. With rings on the rotor, fluorescent penetrant, ultrasonic and special visual techniques are applied. With rings off the rotor, the fluorescent penetrant technique is used, with and without stress enhancement

  8. Ionization cooling ring for muons

    Directory of Open Access Journals (Sweden)

    R. Palmer

    2005-06-01

    Full Text Available Practical ionization cooling rings could lead to lower cost or improved performance in neutrino factory or muon collider designs. The ring modeled here uses realistic three-dimensional fields. The performance of the ring compares favorably with the linear cooling channel used in the second U.S. Neutrino Factory Study. The normalized 6D emittance of an ideal ring is decreased by a factor of approximately 240, compared with a factor of only 15 for the linear channel. We also examine such real-world effects as windows on the absorbers and rf cavities and leaving empty lattice cells for injection and extraction. For realistic conditions the ring decreases the normalized 6D emittance by a factor of 49.

  9. Effect of hybrid fiber reinforcement on the cracking process in fiber reinforced cementitious composites

    DEFF Research Database (Denmark)

    Pereira, Eduardo B.; Fischer, Gregor; Barros, Joaquim A.O.

    2012-01-01

    The simultaneous use of different types of fibers as reinforcement in cementitious matrix composites is typically motivated by the underlying principle of a multi-scale nature of the cracking processes in fiber reinforced cementitious composites. It has been hypothesized that while undergoing...... tensile deformations in the composite, the fibers with different geometrical and mechanical properties restrain the propagation and further development of cracking at different scales from the micro- to the macro-scale. The optimized design of the fiber reinforcing systems requires the objective...... materials is carried out by assessing directly their tensile stress-crack opening behavior. The efficiency of hybrid fiber reinforcements and the multi-scale nature of cracking processes are discussed based on the experimental results obtained, as well as the micro-mechanisms underlying the contribution...

  10. Determination of hoop direction effective elastic moduli of non-circular profile, fiber reinforced polymer composite sewer liner pipes from lateral ring compression tests

    International Nuclear Information System (INIS)

    Czél, Gergely; Takács, Dénes

    2015-01-01

    A new material property determination method is presented for the calculation of effective elastic moduli of non-circular ring specimens cut from filament wound oval profile polymer composite sewer liner pipes. The hoop direction elastic moduli was determined using the test results obtained from ring compression tests, which is a very basic setup, and requires no special equipment. Calculations were executed for many different oval profiles, and diagrams were constructed, from which the cross section dependent C_e_f_f constants can be taken. The new method was validated by the comparison of tests and finite element analysis results. The calculation method and the diagrams are essential design tools for engineers, and a big step forward in sizing non-circular profile liner pipes. - Highlights: • A simple modulus measurement method is presented for non-circular ring specimens. • The evaluation method is validated against a finite element model. • Profile shape dependent constants are presented for a wide range of cross-sections. • A set of charts with the constants are provided to aid design engineers.

  11. Self-gravitation in Saturn's rings

    International Nuclear Information System (INIS)

    Salo, H.; Lukkari, J.

    1982-01-01

    In a ring-shaped collisional system self-gravitation reduces the equilibrium values of the geometric and optical thickness. In Saturn's rings both effects are appreciable. The previously found discrepancy between the calculated profile and the observed profile of the rings is chiefly caused by the omission of self-gravitation. (Auth.)

  12. Saturn’s ring temperatures at equinox

    Science.gov (United States)

    Spilker, Linda J.; Ferrari, C.; Morishima, R.

    2013-10-01

    Modeling the thermal emission of Saturn's rings is challenging due to the numerous heating sources as well as the structural properties of the disk and of the particles that are closely related. At equinox, however, the main rings are externally heated by Saturn alone and the problem is somewhat simplified. We test the abilities of our current models to reproduce the temperatures observed with the Cassini CIRS instrument around equinox in August 2009. A simple semi-analytic model which includes mutual shadowing effects can mostly explain the radial profile of the equinox ring temperatures, except the model predicts lower temperatures than those observed for the A ring. The temperature variation at a given saturnocentric radius is primarily caused by observational geometry variations relative to Saturn. The observed temperature increases with decreasing Saturn-ring-observer angle. In addition, we found evidence that the leading hemispheres of particles are warmer than the trailing hemispheres at least for the C ring and probably for the A and B rings as well. This is explained if some fraction of particles has spin rates lower than the synchronous rotation rate as predicted by N-body simulations. The spin model for a monolayer ring (Ferrari, C., Leyrat, C., 2006, Astron. Astrophys. 447, 745-760) can fit the temperature variations with spacecraft longitude observed in the C ring with currently known thermal properties and a mixing of slow and fast rotators. The multilayer model (Morishima, R., Salo, H., Ohtsuki, K., 2009, Icarus 201, 634-654) can reproduce the temperatures of the B and C rings but gives A ring temperatures that are significantly lower than those observed as does the simple semi-analytic model. More advanced models which take into account self-gravity wakes may explain the A ring temperature behavior.

  13. Split ring containment attachment device

    International Nuclear Information System (INIS)

    Sammel, A.G.

    1996-01-01

    A containment attachment device is described for operatively connecting a glovebag to plastic sheeting covering hazardous material. The device includes an inner split ring member connected on one end to a middle ring member wherein the free end of the split ring member is inserted through a slit in the plastic sheeting to captively engage a generally circular portion of the plastic sheeting. A collar potion having an outer ring portion is provided with fastening means for securing the device together wherein the glovebag is operatively connected to the collar portion. 5 figs

  14. An N-body Integrator for Planetary Rings

    Science.gov (United States)

    Hahn, Joseph M.

    2011-04-01

    A planetary ring that is disturbed by a satellite's resonant perturbation can respond in an organized way. When the resonance lies in the ring's interior, the ring responds via an m-armed spiral wave, while a ring whose edge is confined by the resonance exhibits an m-lobed scalloping along the ring-edge. The amplitude of these disturbances are sensitive to ring surface density and viscosity, so modelling these phenomena can provide estimates of the ring's properties. However a brute force attempt to simulate a ring's full azimuthal extent with an N-body code will likely fail because of the large number of particles needed to resolve the ring's behavior. Another impediment is the gravitational stirring that occurs among the simulated particles, which can wash out the ring's organized response. However it is possible to adapt an N-body integrator so that it can simulate a ring's collective response to resonant perturbations. The code developed here uses a few thousand massless particles to trace streamlines within the ring. Particles are close in a radial sense to these streamlines, which allows streamlines to be treated as straight wires of constant linear density. Consequently, gravity due to these streamline is a simple function of the particle's radial distance to all streamlines. And because particles are responding to smooth gravitating streamlines, rather than discrete particles, this method eliminates the stirring that ordinarily occurs in brute force N-body calculations. Note also that ring surface density is now a simple function of streamline separations, so effects due to ring pressure and viscosity are easily accounted for, too. A poster will describe this N-body method in greater detail. Simulations of spiral density waves and scalloped ring-edges are executed in typically ten minutes on a desktop PC, and results for Saturn's A and B rings will be presented at conference time.

  15. Minimal Gromov-Witten rings

    International Nuclear Information System (INIS)

    Przyjalkowski, V V

    2008-01-01

    We construct an abstract theory of Gromov-Witten invariants of genus 0 for quantum minimal Fano varieties (a minimal class of varieties which is natural from the quantum cohomological viewpoint). Namely, we consider the minimal Gromov-Witten ring: a commutative algebra whose generators and relations are of the form used in the Gromov-Witten theory of Fano varieties (of unspecified dimension). The Gromov-Witten theory of any quantum minimal variety is a homomorphism from this ring to C. We prove an abstract reconstruction theorem which says that this ring is isomorphic to the free commutative ring generated by 'prime two-pointed invariants'. We also find solutions of the differential equation of type DN for a Fano variety of dimension N in terms of the generating series of one-pointed Gromov-Witten invariants

  16. Electro-optical hybrid slip ring

    Science.gov (United States)

    Hong, En

    2005-11-01

    The slip ring is a rotary electrical interface, collector, swivel or rotary joint. It is a physical system that can perform continuous data transfer and data exchange between a stationary and a rotating structure. A slip ring is generally used to transfer data or power from an unrestrained, continuously rotating electro-mechanical system in real-time, thereby simplifying operations and eliminating damage-prone wires dangling from moving joints. Slip rings are widely used for testing, evaluating, developing and improving various technical equipment and facilities with rotating parts. They are widely used in industry, especially in manufacturing industries employing turbo machinery, as in aviation, shipbuilding, aerospace, defense, and in precise facilities having rotating parts such as medical Computerized Tomography (CT) and MRI scanners and so forth. Therefore, any improvement in slip ring technology can impact large markets. Research and development in this field will have broad prospects long into the future. The goal in developing the current slip ring technology is to improve and increase the reliability, stability, anti-interference, and high data fidelity between rotating and stationary structures. Up to now, there have been numerous approaches used for signal and data transfer utilizing a slip ring such as metal contacts, wires, radio transmission, and even liquid media. However, all suffer from drawbacks such as data transfer speed limitations, reliability, stability, electro-magnetic interference and durability. The purpose of the current research is to break through these basic limitations using an optical solution, thereby improving performance in current slip ring applications. This dissertation introduces a novel Electro-Optical Hybrid Slip Ring technology, which makes "through the air" digital-optical communication between stationary and rotating systems a reality with high data transfer speed, better reliability and low interference susceptibility

  17. Double acting stirling engine piston ring

    Science.gov (United States)

    Howarth, Roy B.

    1986-01-01

    A piston ring design for a Stirling engine wherein the contact pressure between the piston and the cylinder is maintained at a uniform level, independent of engine conditions through a balancing of the pressure exerted upon the ring's surface and thereby allowing the contact pressure on the ring to be predetermined through the use of a preloaded expander ring.

  18. Seismic Retrofitting: Reinforced Concrete (RC shear wall versus Reinforcement of RC element by Carbon Fiber Reinforced Polymer (CFRP using PUSHOVER analysis

    Directory of Open Access Journals (Sweden)

    Yahya RIYAD

    2016-12-01

    Full Text Available Seismic retrofitting of constructions vulnerable to earthquakes is a current problem of great political and social relevance. During the last sixty years, moderate to severe earthquakes have occurred in Morocco (specifically in Agadir 1960 and Hoceima 2004. Such events have clearly shown the vulnerability of the building stock in particular and of the built environment in general. Hence, it is very much essential to retrofit the vulnerable building to cope up for the next damaging earthquake. In this paper, the focus will be on a comparative study between two techniques of seismic retrofitting, the first one is a reinforcement using carbon fiber reinforced polymer (CFRP applied to RC elements by bonding , and the second one is a reinforcement with a shear wall. For this study, we will use a non-linear static analysis -also known as Pushover analysis - on a reinforced concrete structure consisting of beams and columns, and composed from eight storey with a gross area of 240 m², designed conforming to the Moroccan Seismic code[1].

  19. Fusion Rings for Quantum Groups

    DEFF Research Database (Denmark)

    Andersen, Henning Haahr; Stroppel, Catharina

    2012-01-01

    We study the fusion rings of tilting modules for a quantum group at a root of unity modulo the tensor ideal of negligible tilting modules. We identify them in type A with the combinatorial rings from [12] and give a similar description of the sp2n-fusion ring in terms of noncommutative symmetric...

  20. Topological rings

    CERN Document Server

    Warner, S

    1993-01-01

    This text brings the reader to the frontiers of current research in topological rings. The exercises illustrate many results and theorems while a comprehensive bibliography is also included. The book is aimed at those readers acquainted with some very basic point-set topology and algebra, as normally presented in semester courses at the beginning graduate level or even at the advanced undergraduate level. Familiarity with Hausdorff, metric, compact and locally compact spaces and basic properties of continuous functions, also with groups, rings, fields, vector spaces and modules, and with Zorn''s Lemma, is also expected.

  1. Energy spectra of quantum rings.

    Science.gov (United States)

    Fuhrer, A; Lüscher, S; Ihn, T; Heinzel, T; Ensslin, K; Wegscheider, W; Bichler, M

    2001-10-25

    Quantum mechanical experiments in ring geometries have long fascinated physicists. Open rings connected to leads, for example, allow the observation of the Aharonov-Bohm effect, one of the best examples of quantum mechanical phase coherence. The phase coherence of electrons travelling through a quantum dot embedded in one arm of an open ring has also been demonstrated. The energy spectra of closed rings have only recently been studied by optical spectroscopy. The prediction that they allow persistent current has been explored in various experiments. Here we report magnetotransport experiments on closed rings in the Coulomb blockade regime. Our experiments show that a microscopic understanding of energy levels, so far limited to few-electron quantum dots, can be extended to a many-electron system. A semiclassical interpretation of our results indicates that electron motion in the rings is governed by regular rather than chaotic motion, an unexplored regime in many-electron quantum dots. This opens a way to experiments where even more complex structures can be investigated at a quantum mechanical level.

  2. Forandringslæring med autismediagnoser?

    DEFF Research Database (Denmark)

    Gustafson, Kari Ingrid; Mørck, Line Lerche

    2013-01-01

    Artiklen drøfter en række aktuelle spørgsmål omkring læring hos børn og unge med autisme-spektrum-forstyrrelses diagnoser. Der introduceres til en social praksisteoretisk forståelse af forandringslæring, der diskuterer forandring ikke kun i relation til en persons identitet, men også aktuelle og...... potentielle forandringer, når det gælder overskridelse af binær logik i autisme versus normalitet, samt i relation til at overskride individualiserede og dualistiske problem-forståelser af fejl og mangler ved det autistiske barn. Det illustreres, hvordan disse former for dualistisk tænkning er forankret i et...... Rasmus’ ændringer i læring, selvforståelse og tilhørsforhold perspektiveres med andre ASF-diagnostiseredes læring udforsket bl.a. gennem gruppeinterviews i regi af Asperger-foreningen. Artiklen byder således på et alternativ i form af at forstå forandringslæring som overskridende læring, med langt større...

  3. The Lord of Rings - the mysterious case of the stolen rings: a critical analysis

    Science.gov (United States)

    Sandrelli, S.

    The Lord of Rings - the mysterious case of the stolen rings: a critical analysis S. Sandrelli INAF - Osservatorio Astronomico di Brera, Milano, Italy (stefano.sandrelli@brera.inaf.it / Fax: 02 72001600 / Phone: +39 02 72320337) "The Lord of Rings - the mysterious case of the stolen rings" is a live astronomical role-playing game for kids aged 10 -13. Its goal is to introduce them to some of the main topics of the Solar System: a) the role of gravity; b) the distribution of mass & light; c) the effects of rotation; d) the distribution of water. The game was held both at the Perugia (2004) and the Genova Science Festival (2005), obtaining great success. Teams of about 6-8 members are introduced to Mr Schioppanelli, the astro-detective of the town (the name is a pun: it reminds Schiaparelli, the famous italian astronomer, and it is a slang expression meaning "ring-breaker"). Mr Schioppanelli has his office in an "gastronomical astronomical observatory", known as The Red Giant Pizzeria. Schioppanelli informs the kids that a mysterious Centaur succeded in stealing the rings of Saturn. The partecipants are appointed astro-detectives in-charge and asked to find the rings by browsing around the Solar System, which is scaled so as to fit the town historical centre or a pedestrian area, going from the Sun to Saturn or beyond, depending on the actual area at disposal. Great care must be taken allowing children playing only in a car-free area of the town. At the right scaled distances, the partecipants meet characters playing as the various planets. The kids can talk to them after solving a riddle, obtaining useful informations. A special characters play as a comet, timely going in and out of the inner solar system. The teams can also talk to some shepherd-moons of the rings. They easily discover that the rings were totally destroyed by the Centaur: a real disaster! They are also suggested to gather the necessary ingredients (gravity, light, rotation, inclination, dust and

  4. Vortex rings in classical and quantum systems

    International Nuclear Information System (INIS)

    Barenghi, C F; Donnelly, R J

    2009-01-01

    The study of vortex rings has been pursued for decades and is a particularly difficult subject. However, the discovery of quantized vortex rings in superfluid helium has greatly increased interest in vortex rings with very thin cores. While rapid progress has been made in the simulation of quantized vortex rings, there has not been comparable progress in laboratory studies of vortex rings in a viscous fluid such as water. This article overviews the history and current frontiers of classical and quantum vortex rings. After introducing the classical results, this review discusses thin-cored vortex rings in superfluid helium in section 2, and recent progress in understanding vortex rings of very thin cores propagating in water in section 3. (invited paper)

  5. Laparoscopic appendicectomy using endo-ring applicator and fallope rings

    International Nuclear Information System (INIS)

    Ali, Iyoob V; Maliekkal, Joji I

    2009-01-01

    Wider adoption of laparoscopic appendicectomy (LA) is limited by problems in securing the appendiceal base as well as the cost and the duration compared with the open procedure. The objective of this study was to assess the feasibility and efficacy of a new method for securing the appendiceal base in LA, so as to make the entire procedure simpler and cheaper, and hence, more popular. Twenty-five patients who were candidates for appendicectomy (emergency as well as elective) and willing for the laparoscopic procedure were selected for this study. Ports used were 10 mm at the umbilicus, 5 mm at the lower right iliac fossa, and 10 mm at the left iliac fossa. Extremely friable, ruptured, or turgid organs of diameters larger than 8 mm were excluded from the study. The mesoappendix was divided close to the appendix by diathermy. Fallope rings were applied to the appendiceal base using a special ring applicator, and the appendix was divided and extracted through the lumen of the applicator. The procedure was successful in 23 (92%) cases, and the mean duration of the procedure was 20 minutes (15-32 minutes). There were no procedural complications seen during a median follow-up of two weeks. The equipment and rings were cheaper when compared with that of the standard methods of securing the base of the appendix. LA using fallope rings is a safe, simple, easy-to-learn, and economically viable method. (author)

  6. SMARANDACHE NON-ASSOCIATIVE RINGS

    OpenAIRE

    Vasantha, Kandasamy

    2002-01-01

    An associative ring is just realized or built using reals or complex; finite or infinite by defining two binary operations on it. But on the contrary when we want to define or study or even introduce a non-associative ring we need two separate algebraic structures say a commutative ring with 1 (or a field) together with a loop or a groupoid or a vector space or a linear algebra. The two non-associative well-known algebras viz. Lie algebras and Jordan algebras are mainly built using a vecto...

  7. Heavy ion storage rings

    International Nuclear Information System (INIS)

    Schuch, R.

    1987-01-01

    A brief overview of synchrotron storage rings for heavy ions, which are presently under construction in different accelerator laboratories is given. Ions ranging from protons up to uranium ions at MeV/nucleon energies will be injected into these rings using multiturn injection from the accelerators available or being built in these laboratories. After injection, it is planned to cool the phase space distribution of the ions by merging them with cold electron beams or laser beams, or by using stochastic cooling. Some atomic physics experiments planned for these rings are presented. 35 refs

  8. FOAM CONCRETE REINFORCEMENT BY BASALT FIBRES

    Directory of Open Access Journals (Sweden)

    Zhukov Aleksey Dmitrievich

    2012-10-01

    Full Text Available The authors demonstrate that the foam concrete performance can be improved by dispersed reinforcement, including methods that involve basalt fibres. They address the results of the foam concrete modeling technology and assess the importance of technology-related parameters. Reinforcement efficiency criteria are also provided in the article. Dispersed reinforcement improves the plasticity of the concrete mix and reduces the settlement crack formation rate. Conventional reinforcement that involves metal laths and rods demonstrates its limited application in the production of concrete used for thermal insulation and structural purposes. Dispersed reinforcement is preferable. This technology contemplates the infusion of fibres into porous mixes. Metal, polymeric, basalt and glass fibres are used as reinforcing components. It has been identified that products reinforced by polypropylene fibres demonstrate substantial abradability and deformability rates even under the influence of minor tensile stresses due to the low adhesion strength of polypropylene in the cement matrix. The objective of the research was to develop the type of polypropylene of D500 grade that would demonstrate the operating properties similar to those of Hebel and Ytong polypropylenes. Dispersed reinforcement was performed by the basalt fibre. This project contemplates an autoclave-free technology to optimize the consumption of electricity. Dispersed reinforcement is aimed at the reduction of the block settlement in the course of hardening at early stages of their operation, the improvement of their strength and other operating properties. Reduction in the humidity rate of the mix is based on the plasticizing properties of fibres, as well as the application of the dry mineralization method. Selection of optimal parameters of the process-related technology was performed with the help of G-BAT-2011 Software, developed at Moscow State University of Civil Engineering. The authors also

  9. Moving ring reactor 'Karin-1'

    International Nuclear Information System (INIS)

    1983-12-01

    The conceptual design of a moving ring reactor ''Karin-1'' has been carried out to advance fusion system design, to clarify the research and development problems, and to decide their priority. In order to attain these objectives, a D-T reactor with tritium breeding blanket is designed, a commercial reactor with net power output of 500 MWe is designed, the compatibility of plasma physics with fusion engineering is demonstrated, and some other guideline is indicated. A moving ring reactor is composed mainly of three parts. In the first formation section, a plasma ring is formed and heated up to ignition temperature. The plasma ring of compact torus is transported from the formation section through the next burning section to generate fusion power. Then the plasma ring moves into the last recovery section, and the energy and particles of the plasma ring are recovered. The outline of a moving ring reactor ''Karin-1'' is described. As a candidate material for the first wall, SiC was adopted to reduce the MHD effect and to minimize the interaction with neutrons and charged particles. The thin metal lining was applied to the SiC surface to solve the problem of the compatibility with lithium blanket. Plasma physics, the engineering aspect and the items of research and development are described. (Kako, I.)

  10. Tinkering at the main-ring lattice

    Energy Technology Data Exchange (ETDEWEB)

    Ohnuma, S.

    1982-08-23

    To improve production of usable antiprotons using the proton beam from the main ring and the lossless injection of cooled antiprotons into the main ring, modifications of the main ring lattice are recommended.

  11. The ring plus project: safety and acceptability of vaginal rings that protect women from unintended pregnancy

    OpenAIRE

    Schurmans, C?line; De Baetselier, Irith; Kestelyn, Evelyne; Jespers, Vicky; Delvaux, Th?r?se; Agaba, Stephen K; van Loen, Harry; Menten, Joris; van de Wijgert, Janneke; Crucitti, Tania

    2015-01-01

    Background Research is ongoing to develop multipurpose vaginal rings to be used continuously for contraception and to prevent Human Immunodeficiency Virus (HIV) infection. Contraceptive vaginal rings (CVRs) are available in a number of countries and are most of the time used intermittently i.e. three weeks out of a 4-week cycle. Efficacy trials with a dapivirine-containing vaginal ring for HIV prevention are ongoing and plans to develop multi-purpose vaginal rings for prevention of both HIV a...

  12. Pyrimidine-pyridine ring interconversion

    NARCIS (Netherlands)

    Plas, van der H.C.

    2003-01-01

    This chapter discusses the pyrimidine-to-pyridine ring transformation and pyridine-to-pyrimidine ring transformation. In nucleophile-induced pyrimidine-to-pyridine rearrangements, two types of reactions can be distinguished depending on the structure of the nucleophile: (1) reactions in which the

  13. Electron beam cooling at a magnetic storage ring, TARN II, and an electrostatic storage ring

    International Nuclear Information System (INIS)

    Tanabe, Tetsumi

    2006-01-01

    At the High Energy Accelerator Research Organization (KEK), a magnetic storage ring, TARN II, with an electron cooler was operated from 1989 to 1999, while an electrostatic storage ring with a small electron cooler has been operational since 2000. In this paper, the electron cooling at TARN II and the electrostatic storage ring is described. (author)

  14. Leapfrogging of multiple coaxial viscous vortex rings

    International Nuclear Information System (INIS)

    Cheng, M.; Lou, J.; Lim, T. T.

    2015-01-01

    A recent theoretical study [Borisov, Kilin, and Mamaev, “The dynamics of vortex rings: Leapfrogging, choreographies and the stability problem,” Regular Chaotic Dyn. 18, 33 (2013); Borisov et al., “The dynamics of vortex rings: Leapfrogging in an ideal and viscous fluid,” Fluid Dyn. Res. 46, 031415 (2014)] shows that when three coaxial vortex rings travel in the same direction in an incompressible ideal fluid, each of the vortex rings alternately slips through (or leapfrogs) the other two ahead. Here, we use a lattice Boltzmann method to simulate viscous vortex rings with an identical initial circulation, radius, and separation distance with the aim of studying how viscous effect influences the outcomes of the leapfrogging process. For the case of two identical vortex rings, our computation shows that leapfrogging can be achieved only under certain favorable conditions, which depend on Reynolds number, vortex core size, and initial separation distance between the two rings. For the case of three coaxial vortex rings, the result differs from the inviscid model and shows that the second vortex ring always slips through the leading ring first, followed by the third ring slipping through the other two ahead. A simple physical model is proposed to explain the observed behavior

  15. The possibility of using high strength reinforced concrete

    International Nuclear Information System (INIS)

    Miura, Nobuaki

    1991-01-01

    There is recently much research about and developments in reinforced concrete using high strength concrete and reinforcement. As a result, some high-rise buildings and nuclear buildings have been constructed with such concrete. Reinforced concrete will be stronger in the future, but there is a limit to its strength defined by the character of the materials and also by the character of the reinforced concrete members made of the concrete and reinforcement. This report describes the merits and demerits of using high strength reinforced concrete. (author)

  16. Reinforced concrete wall under hydrogen detonation

    International Nuclear Information System (INIS)

    Saarenheimo, A.

    2000-11-01

    The structural integrity of a reinforced concrete wall in the BWR reactor building under hydrogen detonation conditions has been analysed. Of particular interest is whether the containment integrity can be jeopardised by an external hydrogen detonation. The load carrying capacity of a reinforced concrete wall was studied. The detonation pressure loads were estimated with computerised hand calculations assuming a direct initiation of detonation and applying the strong explosion theory. The results can be considered as rough and conservative estimates for the first shock pressure impact induced by a reflecting detonation wave. Structural integrity may be endangered due to slow pressurisation or dynamic impulse loads associated with local detonations. The static pressure following the passage of a shock front may be relatively high, thus this static or slowly decreasing pressure after a detonation may damage the structure severely. The mitigating effects of the opening of a door on pressure history and structural response were also studied. The non-linear behaviour of the wall was studied under detonations corresponding a detonable hydrogen mass of 0.5 kg and 1.428 kg. Non-linear finite element analyses of the reinforced concrete structure were carried out by the ABAQUS/Explicit program. The reinforcement and its non-linear material behaviour and the tensile cracking of concrete were modelled. Reinforcement was defined as layers of uniformly spaced reinforcing bars in shell elements. In these studies the surrounding structures of the non-linearly modelled reinforced concrete wall were modelled using idealised boundary conditions. Especially concrete cracking and yielding of the reinforcement was monitored during the numerical simulation. (au)

  17. Redox shuttles having an aromatic ring fused to a 1,1,4,4-tetrasubstituted cyclohexane ring

    Science.gov (United States)

    Weng, Wei; Zhang, Zhengcheng; Amine, Khalil

    2015-12-01

    An electrolyte includes an alkali metal salt; an aprotic solvent; and a redox shuttle additive including an aromatic compound having at least one aromatic ring fused with at least one non-aromatic ring, the aromatic ring having two or more oxygen or phosphorus-containing substituents.

  18. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  19. Reinforcement Learning State-of-the-Art

    CERN Document Server

    Wiering, Marco

    2012-01-01

    Reinforcement learning encompasses both a science of adaptive behavior of rational beings in uncertain environments and a computational methodology for finding optimal behaviors for challenging problems in control, optimization and adaptive behavior of intelligent agents. As a field, reinforcement learning has progressed tremendously in the past decade. The main goal of this book is to present an up-to-date series of survey articles on the main contemporary sub-fields of reinforcement learning. This includes surveys on partially observable environments, hierarchical task decompositions, relational knowledge representation and predictive state representations. Furthermore, topics such as transfer, evolutionary methods and continuous spaces in reinforcement learning are surveyed. In addition, several chapters review reinforcement learning methods in robotics, in games, and in computational neuroscience. In total seventeen different subfields are presented by mostly young experts in those areas, and together the...

  20. Interaction of Vortex Ring with Cutting Plate

    Science.gov (United States)

    Musta, Mustafa

    2015-11-01

    The interaction of a vortex ring impinging on a thin cutting plate was made experimentally using Volumetric 3-component Velocitmetry (v3v) technique. The vortex rings were generated with piston-cylinder vortex ring generator using piston stroke-to-diameter ratios and Re at 2-3 and 1500 - 3000, respectively. The cutting of vortex rings below center line leads to the formation of secondary vortices on each side of the plate which is look like two vortex rings, and a third vortex ring propagates further downstream in the direction of the initial vortex ring, which is previously showed by flow visualization study of Weigand (1993) and called ``trifurcation''. Trifurcation is very sensitive to the initial Reynolds number and the position of the plate with respect to the vortex ring generator pipe. The present work seeks more detailed investigation on the trifurcation using V3V technique. Conditions for the formation of trifurcation is analyzed and compared with Weigand (1993). The formed secondary vortex rings and the propagation of initial vortex ring in the downstream of the plate are analyzed by calculating their circulation, energy and trajectories.

  1. Reinforced aortic root reconstruction for acute type A aortic dissection involving the aortic root

    Directory of Open Access Journals (Sweden)

    Han Qing-qi

    2013-06-01

    Full Text Available OBJECTIVE: There are debates regarding the optimal approach for AAAD involving the aortic root. We described a modified reinforced aortic root reconstruction approach for treating AAAD involving the aortic root. METHODS: A total of 161 patients with AAAD involving the aortic root were treated by our modified reinforced aortic root reconstruction approach from January 1998 to December 2008. Key features of our modified approach were placement of an autologous pericardial patch in the false lumen, lining of the sinotubular junction lumen with a polyester vascular ring, and wrapping of the vessel with Teflon strips. Outcome measures included post-operative mortality, survival, complications, and level of aortic regurgitation. RESULTS: A total of 161 patients were included in the study (mean age: 43.3 1 15.5 years. The mean duration of follow-up was 5.1 1 2.96 years (2-12 years. A total of 10 (6.2% and 11 (6.8% patients died during hospitalization and during follow-up, respectively. Thirty-one (19.3% patients experienced postoperative complications. The 1-, 3-, 5-, and 10-year survival rates were 99.3%, 98%, 93.8%, and 75.5%, respectively. There were no instances of recurrent aortic dissection, aortic aneurysm, or pseudoaneurysm during the entire study period. The severity of aortic regurgitation dramatically decreased immediately after surgery (from 28.6% to 0% grade 3-4 and thereafter slightly increased (from 0% to 7.2% at 5 years and 9.1% at 10 years. CONCLUSION: This modified reinforced aortic root reconstruction was feasible, safe and durable/effective, as indicated by its low mortality, low postoperative complications and high survival rate.

  2. Magnetic ring for stripping enhancement

    International Nuclear Information System (INIS)

    Selph, F.

    1992-10-01

    A ring designed to recycle ions through a stripping medium offers the possibility for increasing output of the desired charge state by up to 4x. This could be a very important component of a Radioactive Nuclear Beam Facility. In order for such a ring to work effectively it must satisfy certain design conditions. These include achromaticity at the stripper, a dispersed region for an extraction magnet, and a number of first and higher order optics constraints which are necessary to insure that the beam emittance is not degraded unduly by the ring. An example is given of a candidate design of a stripping ring

  3. Acceleration of magnetized plasma rings

    International Nuclear Information System (INIS)

    Hartman, D.; Eddleman, J.; Hammer, J.H.

    1982-01-01

    One scheme is considered, acceleration of a ring between coaxial electrodes by a B/sub theta/ field as in a coaxial rail-gun. If the electrodes are conical, a ring accelerated towards the apex of the cone undergoes self-similar compression (focussing) during acceleration. Because the allowable acceleration force F/sub a/ = kappa U/sub m//R (kappa - 2 , the accelerating distance for conical electrodes is considerably shortened over that required for coaxial electrodes. In either case however, since the accelerating flux can expand as the ring moves, most of the accelerating field energy can be converted into kinetic energy of the ring leading to high efficiency

  4. Facilitating tolerance of delayed reinforcement during functional communication training.

    Science.gov (United States)

    Fisher, W W; Thompson, R H; Hagopian, L P; Bowman, L G; Krug, A

    2000-01-01

    Few clinical investigations have addressed the problem of delayed reinforcement. In this investigation, three individuals whose destructive behavior was maintained by positive reinforcement were treated using functional communication training (FCT) with extinction (EXT). Next, procedures used in the basic literature on delayed reinforcement and self-control (reinforcer delay fading, punishment of impulsive responding, and provision of an alternative activity during reinforcer delay) were used to teach participants to tolerate delayed reinforcement. With the first case, reinforcer delay fading alone was effective at maintaining low rates of destructive behavior while introducing delayed reinforcement. In the second case, the addition of a punishment component reduced destructive behavior to near-zero levels and facilitated reinforcer delay fading. With the third case, reinforcer delay fading was associated with increases in masturbation and head rolling, but prompting and praising the individual for completing work during the delay interval reduced all problem behaviors and facilitated reinforcer delay fading.

  5. Reinforced Conductive Polyaniline-Paper Composites

    Directory of Open Access Journals (Sweden)

    Jinhua Yan

    2015-05-01

    Full Text Available A method for direct aniline interfacial polymerization on polyamideamine-epichlorohydrin (PAE-reinforced paper substrate is introduced in this paper. Cellulose-based papers with and without reinforcement were considered. The polyaniline (PANI-paper composites had surface resistivity lower than 100 Ω/sq after more than 3 polymerizations. Their mechanical strength and thermal stability were analyzed by tensile tests and thermogravimetric analysis (TGA. Fourier transform infrared (FTIR results revealed that there was strong interaction between NH groups in aniline monomers and OH groups in fibers, which did not disappear until after 3 polymerizations. Scanning electron microscopy (SEM and field emission (FE SEM images showed morphological differences between composites using reinforced and untreated base papers. Conductive composites made with PAE-reinforced base paper had both good thermal stability and good mechanical strength, with high conductivity and a smaller PANI amount.

  6. A first course in noncommutative rings

    CERN Document Server

    Lam, T Y

    2001-01-01

    A First Course in Noncommutative Rings, an outgrowth of the author's lectures at the University of California at Berkeley, is intended as a textbook for a one-semester course in basic ring theory. The material covered includes the Wedderburn-Artin theory of semisimple rings, Jacobson's theory of the radical, representation theory of groups and algebras, prime and semiprime rings, local and semilocal rings, perfect and semiperfect rings, etc. By aiming the level of writing at the novice rather than the connoisseur and by stressing th the role of examples and motivation, the author has produced a text that is suitable not only for use in a graduate course, but also for self- study in the subject by interested graduate students. More than 400 exercises testing the understanding of the general theory in the text are included in this new edition.

  7. Superelastic SMA–FRP composite reinforcement for concrete structures

    International Nuclear Information System (INIS)

    Wierschem, Nicholas; Andrawes, Bassem

    2010-01-01

    For many years there has been interest in using fiber-reinforced polymers (FRPs) as reinforcement in concrete structures. Unfortunately, due to their linear elastic behavior, FRP reinforcing bars are never considered for structural damping or dynamic applications. With the aim of improving the ductility and damping capability of concrete structures reinforced with FRP reinforcement, this paper studies the application of SMA–FRP, a relatively novel type of composite reinforced with superelastic shape memory alloy (SMA) wires. The cyclic tensile behavior of SMA–FRP composites are studied experimentally and analytically. Tests of SMA–FRP composite coupons are conducted to determine their constitutive behavior. The experimental results are used to develop and calibrate a uniaxial SMA–FRP analytical model. Parametric and case studies are performed to determine the efficacy of the SMA–FRP reinforcement in concrete structures and the key factors governing its behavior. The results show significant potential for SMA–FRP reinforcement to improve the ductility and damping of concrete structures while still maintaining its elastic characteristic, typical of FRP reinforcement

  8. Positive behavioral contrast across food and alcohol reinforcers.

    OpenAIRE

    McSweeney, F K; Melville, C L; Higa, J

    1988-01-01

    The present study examined behavioral contrast during concurrent and multiple schedules that provided food and alcohol reinforcers. Concurrent-schedule contrast occurred in the responding reinforced by food when alcohol reinforcers were removed. It also occurred in the responding reinforced by alcohol when food was removed. Multiple-schedule contrast appeared for food when alcohol reinforcers were removed, but not for alcohol when food was removed. These results show that behavioral contrast ...

  9. Design of Piston Ring Friction Tester Apparatus

    DEFF Research Database (Denmark)

    Klit, Peder

    2006-01-01

    One of the major prerequisites for calculating piston ring friction is a good description of the tribological situation. Piston rings operate in three different lubrication regimes and the theoretical models should be capable to describe this. A very important condition for describing the frictio......One of the major prerequisites for calculating piston ring friction is a good description of the tribological situation. Piston rings operate in three different lubrication regimes and the theoretical models should be capable to describe this. A very important condition for describing...... the frictional behavior of a piston ring correctly is knowledge about the amount of lubricant present. For piston rings the external load may be established by measuring the pressure distribution, i.e. the pressure drop in the piston ring package. Speed and temperature may also be established. The amount...... available is reflected in the friction absorbed in the bearing. The following properties will be measured: Oil fillm thickness - along liner (axial variation), oil film thickness - along piston ring (circumferential variation), piston tilt, temperature of piston rings and liner, pressure at piston lands...

  10. Study for ILC Damping Ring at KEKB

    Energy Technology Data Exchange (ETDEWEB)

    Flanagan, J.W.; Fukuma, H.; Kanazawa, K.I.; Koiso, H.; Masuzawa, M.; Ohmi, Kazuhito; Ohnishi, Y.; Oide, Katsunobu; Suetsugu, Y.; Tobiyama, M.; /KEK, Tsukuba; Pivi, M.; /SLAC

    2011-11-04

    ILC damping ring consists of very low emittance electron and positron storage rings. It is necessary for ILC damping ring to study electron cloud effects in such low emittance positron ring. We propose a low emittance operation of KEKB to study the effects.

  11. Planetary ring systems properties, structures, and evolution

    CERN Document Server

    Murray, Carl D

    2018-01-01

    Planetary rings are among the most intriguing structures of our solar system and have fascinated generations of astronomers. Collating emerging knowledge in the field, this volume reviews our current understanding of ring systems with reference to the rings of Saturn, Uranus, Neptune, and more. Written by leading experts, the history of ring research and the basics of ring–particle orbits is followed by a review of the known planetary ring systems. All aspects of ring system science are described in detail, including specific dynamical processes, types of structures, thermal properties and their origins, and investigations using computer simulations and laboratory experiments. The concluding chapters discuss the prospects of future missions to planetary rings, the ways in which ring science informs and is informed by the study of other astrophysical disks, and a perspective on the field's future. Researchers of all levels will benefit from this thorough and engaging presentation.

  12. Longitudinal beam instability due to the ring impedance at KEK's accelerator test facility damping ring

    International Nuclear Information System (INIS)

    Kim, Eun-San

    2003-01-01

    This paper shows the results of a numerical study of the impedance in the Accelerator Test Facility damping ring. The longitudinal impedance in the damping ring is shown to be inductive. It is shown that the total impedance |Z || /n| is 0.23 Ω and the inductance is L = 14 nH. In the extremely low emittance beam of the damping ring, bunch lengthening is caused by both the effects of potential-well distortion and intra-beam scattering. In this paper, the bunch-lengthening due to the ring impedance is numerically investigated, and the result shows qualitative agreement with the result of an analysis performed using the bunch-length measurement. With the calculated longitudinal impedance, the instability threshold in the damping ring is estimated to be a bunch population of 3.3 x 10 10 by using both a Vlasov equation approach and a multi-particle tracking method.

  13. Learning to trade via direct reinforcement.

    Science.gov (United States)

    Moody, J; Saffell, M

    2001-01-01

    We present methods for optimizing portfolios, asset allocations, and trading systems based on direct reinforcement (DR). In this approach, investment decision-making is viewed as a stochastic control problem, and strategies are discovered directly. We present an adaptive algorithm called recurrent reinforcement learning (RRL) for discovering investment policies. The need to build forecasting models is eliminated, and better trading performance is obtained. The direct reinforcement approach differs from dynamic programming and reinforcement algorithms such as TD-learning and Q-learning, which attempt to estimate a value function for the control problem. We find that the RRL direct reinforcement framework enables a simpler problem representation, avoids Bellman's curse of dimensionality and offers compelling advantages in efficiency. We demonstrate how direct reinforcement can be used to optimize risk-adjusted investment returns (including the differential Sharpe ratio), while accounting for the effects of transaction costs. In extensive simulation work using real financial data, we find that our approach based on RRL produces better trading strategies than systems utilizing Q-learning (a value function method). Real-world applications include an intra-daily currency trader and a monthly asset allocation system for the S&P 500 Stock Index and T-Bills.

  14. Enhanced thermal and mechanical properties of PLA/MoS2 nanocomposites synthesized via the in-situ ring-opening polymerization

    Science.gov (United States)

    Chen, Pengpeng; Liang, Xiao; Xu, Ying; Zhou, Yifeng; Nie, Wangyan

    2018-05-01

    In this work, MoS2 nanosheets were employed to reinforce PLA. In order to promote the homogeneous dispersion of MoS2 in PLA and form a strong interface between MoS2 and PLA, the MoS2 nanosheets were firstly modified by mercapto-ethylamine, and then functionalized with PLA chains through ring-opening polymerization of poly(L-lactide). The XRD, XPS, TGA and 1H NMR characterizations confirmed the successful amino and PLA functionalization of MoS2 nanosheets. The obtained MoS2-g-PLA nanosheets were then introduced to reinforce PLA. SEM images displayed that the MoS2-g-PLA nanosheets were dispersed in PLA matrix uniformly. TGA results showed that initial decomposition temperature was improved from 275.6 °C to 334.8 °C with 0.5 wt% of MoS2-g-PLA nanosheets. The storage modulus of PLA/MoS2-g-PLA-0.5 wt% in the glass state and rubber state were both greatly enhanced compared with neat PLA.

  15. Enhancement of shear strength and ductility for reinforced concrete wide beams due to web reinforcement

    Directory of Open Access Journals (Sweden)

    M. Said

    2013-12-01

    Full Text Available The shear behavior of reinforced concrete wide beams was investigated. The experimental program consisted of nine beams of 29 MPa concrete strength tested with a shear span-depth ratio equal to 3.0. One of the tested beams had no web reinforcement as a control specimen. The flexure mode of failure was secured for all of the specimens to allow for shear mode of failure. The key parameters covered in this investigation are the effect of the existence, spacing, amount and yield stress of the vertical stirrups on the shear capacity and ductility of the tested wide beams. The study shows that the contribution of web reinforcement to the shear capacity is significant and directly proportional to the amount and spacing of the shear reinforcement. The increase in the shear capacity ranged from 32% to 132% for the range of the tested beams compared with the control beam. High grade steel was more effective in the contribution of the shear strength of wide beams. Also, test results demonstrate that the shear reinforcement significantly enhances the ductility of the wide beams. In addition, shear resistances at failure recorded in this study are compared to the analytical strengths calculated according to the current Egyptian Code and the available international codes. The current study highlights the need to include the contribution of shear reinforcement in the Egyptian Code requirements for shear capacity of wide beams.

  16. Fibre Reinforced Polymer Composites as Internal and External Reinforcements for Building Elements

    Directory of Open Access Journals (Sweden)

    Cătălin Banu

    2008-01-01

    Full Text Available During the latest decades fibre reinforced polymer (FRP composite materials have proven valuable properties and suitable to be used in construction of new buildings and in upgrading the existing ones. These materials have covered the road from research laboratory and demonstration projects to implementation in actual structures. Nowadays the civil and structural engineering communities are about to commence the stage in which the use of FRP composites is becoming a routine similar to that of traditional material such as concrete, masonry and wood. Two main issues are presented in this paper, the use of FRP composite materials for new structural members (internal reinforcements and strengthening of existing members (externally bonded reinforcements. The advantages and disadvantages as well as the problems and constraints associated with both issues are discussed in detail mainly related to concrete members.

  17. Accretion in Saturn's F Ring

    Science.gov (United States)

    Meinke, B. K.; Esposito, L. W.; Stewart, G.

    2012-12-01

    Saturn's F ring is the solar system's principal natural laboratory for direct observation of accretion and disruption processes. The ring resides in the Roche zone, where tidal disruption competes with self-gravity, which allows us to observe the lifecycle of moonlets. Just as nearby moons create structure at the B ring edge (Esposito et al. 2012) and the Keeler gap (Murray 2007), the F ring "shepherding" moons Prometheus and Pandora stir up ring material and create observably changing structures on timescales of days to decades. In fact, Beurle et al (2010) show that Prometheus makes it possible for "distended, yet gravitationally coherent clumps" to form in the F ring, and Barbara and Esposito (2002) predicted a population of ~1 km bodies in the ring. In addition to the observations over the last three decades, the Cassini Ultraviolet Imaging Spectrograph (UVIS) has detected 27 statistically significant features in 101 occultations by Saturn's F ring since July 2004. Seventeen of those 27 features are associated with clumps of ring material. Two features are opaque in occultation, which makes them candidates for solid objects, which we refer to as Moonlets. The 15 other features partially block stellar signal for 22 m to just over 3.7 km along the radial expanse of the occultation. Upon visual inspection of the occultation profile, these features resemble Icicles, thus we will refer to them as such here. The density enhancements responsible for such signal attenuations are likely due to transient clumping of material, evidence that aggregations of material are ubiquitous in the F ring. Our lengthy observing campaign reveals that Icicles are likely transient clumps, while Moonlets are possible solid objects. Optical depth is an indicator of clumping because more-densely aggregated material blocks more light; therefore, it is natural to imagine moonlets as later evolutionary stage of icicle, when looser clumps of material compact to form a feature that appears

  18. Strength Characteristics of Reinforced Sandy Soil

    OpenAIRE

    S. N. Bannikov; Mahamed Al Fayez

    2005-01-01

    Laboratory tests on determination of reinforced sandy soil strength characteristics (angle of internal friction, specific cohesive force) have been carried out with the help of a specially designed instrument and proposed methodology. Analysis of the obtained results has revealed that cohesive forces are brought about in reinforced sandy soil and an angle of internal soil friction becomes larger in comparison with non-reinforced soil.

  19. Nonlinear analysis of ring oscillator circuits

    KAUST Repository

    Ge, Xiaoqing

    2010-06-01

    Using nonlinear systems techniques, we analyze the stability properties and synchronization conditions for ring oscillator circuits, which are essential building blocks in digital systems. By making use of its cyclic structure, we investigate local and global stability properties of an n-stage ring oscillator. We present a sufficient condition for global asymptotic stability of the origin and obtain necessity if the ring oscillator consists of identical inverter elements. We then give a synchronization condition for identical interconnected ring oscillators.

  20. Nonlinear analysis of ring oscillator circuits

    KAUST Repository

    Ge, Xiaoqing; Arcak, Murat; Salama, Khaled N.

    2010-01-01

    Using nonlinear systems techniques, we analyze the stability properties and synchronization conditions for ring oscillator circuits, which are essential building blocks in digital systems. By making use of its cyclic structure, we investigate local and global stability properties of an n-stage ring oscillator. We present a sufficient condition for global asymptotic stability of the origin and obtain necessity if the ring oscillator consists of identical inverter elements. We then give a synchronization condition for identical interconnected ring oscillators.

  1. Quality Assurance Project Plan for Verification of Sediment Ecotoxicity Assessment Ring(SEA Ring)

    Science.gov (United States)

    The objective of the verification is to test the efficacy and ability of the Sediment Ecotoxicity Assessment Ring (SEA Ring) to evaluate the toxicity of contaminants in the sediment, at the sediment-water interface, and WC to organisms that live in those respective environments.

  2. Dynamical Evolution of Ring-Satellite Systems

    Science.gov (United States)

    Ohtsuki, Keiji

    2005-01-01

    The goal of this research was to understand dynamical processes related to the evolution of size distribution of particles in planetary rings and application of theoretical results to explain features in the present rings of giant planets. We studied velocity evolution and accretion rates of ring particles in the Roche zone. We developed a new numerical code for the evolution of ring particle size distribution, which takes into account the above results for particle velocity evolution and accretion rates. We also studied radial diffusion rate of ring particles due to inelastic collisions and gravitational encounters. Many of these results can be also applied to dynamical evolution of a planetesimal disk. Finally, we studied rotation rates of moonlets and particles in planetary rings, which would influence the accretional evolution of these bodies. We describe our key accomplishments during the past three years in more detail in the following.

  3. Analytical, Numerical and Experimental Examination of Reinforced Composites Beams Covered with Carbon Fiber Reinforced Plastic

    Science.gov (United States)

    Kasimzade, A. A.; Tuhta, S.

    2012-03-01

    In the article, analytical, numerical (Finite Element Method) and experimental investigation results of beam that was strengthened with fiber reinforced plastic-FRP composite has been given as comparative, the effect of FRP wrapping number to the maximum load and moment capacity has been evaluated depending on this results. Carbon FRP qualitative dependences have been occurred between wrapping number and beam load and moment capacity for repair-strengthen the reinforced concrete beams with carbon fiber. Shown possibilities of application traditional known analysis programs, for the analysis of Carbon Fiber Reinforced Plastic (CFRP) strengthened structures.

  4. Propellers in Saturn's rings

    Science.gov (United States)

    Sremcevic, M.; Stewart, G. R.; Albers, N.; Esposito, L. W.

    2013-12-01

    Theoretical studies and simulations have demonstrated the effects caused by objects embedded in planetary rings. Even if the objects are too small to be directly observed, each creates a much larger gravitational imprint on the surrounding ring material. These strongly depend on the mass of the object and range from "S" like propeller-shaped structures for about 100m-sized icy bodies to the opening of circumferential gaps as in the case of the embedded moons Pan and Daphnis and their corresponding Encke and Keeler Gaps. Since the beginning of the Cassini mission many of these smaller objects (~data from Cassini Ultraviolet Imaging Spectrograph (UVIS) and Imaging Science Subsystem (ISS) experiments. We show evidence that B ring seems to harbor two distinct populations of propellers: "big" propellers covering tens of degrees in azimuth situated in the densest part of B ring, and "small" propellers in less dense inner B ring that are similar in size and shape to known A ring propellers. The population of "big" propellers is exemplified with a single object which is observed for 5 years of Cassini data. The object is seen as a very elongated bright stripe (40 degrees wide) in unlit Cassini images, and dark stripe in lit geometries. In total we report observing the feature in images at 18 different epochs between 2005 and 2010. In UVIS occultations we observe this feature as an optical depth depletion in 14 out of 93 occultation cuts at corrotating longitudes compatible with imaging data. Combining the available Cassini data we infer that the object is a partial gap located at r=112,921km embedded in the high optical depth region of the B ring. The gap moves at Kepler speed appropriate for its radial location. Radial offsets of the gap locations in UVIS occultations are consistent with an asymmetric propeller shape. The asymmetry of the observed shape is most likely a consequence of the strong surface mass density gradient, as the feature is located at an edge between

  5. Cosmic rings from colliding galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Mitton, S

    1976-11-18

    Research on two ring galaxies has led to the proposal of an interaction model to account for the rings. It is envisaged that this class of galaxy is created when a compact galaxy crashes through the disc of a spiral galaxy. The results of a spectroscopic investigation of the galaxy known as the Cartwheel and of another ring galaxy 11 NZ 4 are discussed. The general picture of ring galaxies which emerges from these studies of a massive starry nucleus with a necklace of emitting gas and some spokes and along the spin axis of the wheel a small companion galaxy that is devoid of interstellar gas. An explanation of these properties is considered.

  6. Producing Durable Continuously Reinforced Concrete Pavement using Glass-ceramic Coated Reinforcing Steel

    Science.gov (United States)

    2010-02-01

    reinforcement if the enamel is broken  Embedded cement grains hydrate if enamel is cracked to self-heal with the formation of calcium silicate hydrate Goal...Reinforced Concrete Pavement The 600% volume change in the iron to iron oxide formation put the concrete in tension and it cracks an spalls BUILDING...corrodes prematurely and delaminates the pavement  Moisture and chlorides can move through the natural porosity of concrete and the cracks in the

  7. Constitutive model for reinforced concrete

    NARCIS (Netherlands)

    Feenstra, P.H.; Borst, de R.

    1995-01-01

    A numerical model is proposed for reinforced-concrete behavior that combines the commonly accepted ideas from modeling plain concrete, reinforcement, and interaction behavior in a consistent manner. The behavior of plain concrete is govern by fracture-energy-level-based formulation both in tension

  8. Tangible Reinforcers: Bonuses or Bribes?

    Science.gov (United States)

    O'Leary, K. Daniel; And Others

    1972-01-01

    Objections to the use of tangible reinforcers, such as prizes, candy, cigarettes, and money, are discussed. Treatment programs using tangible reinforcers are recommended as powerful modifers of behavior to be implemented only after less powerful means of modification have been tried. (Author)

  9. Determination of corrosion rate of reinforcement with a modulated guard ring electrode; analysis of errors due to lateral current distribution

    International Nuclear Information System (INIS)

    Wojtas, H.

    2004-01-01

    The main source of errors in measuring the corrosion rate of rebars on site is a non-uniform current distribution between the small counter electrode (CE) on the concrete surface and the large rebar network. Guard ring electrodes (GEs) are used in an attempt to confine the excitation current within a defined area. In order to better understand the functioning of modulated guard ring electrode and to assess its effectiveness in eliminating errors due to lateral spread of current signal from the small CE, measurements of the polarisation resistance performed on a concrete beam have been numerically simulated. Effect of parameters such as rebar corrosion activity, concrete resistivity, concrete cover depth and size of the corroding area on errors in the estimation of polarisation resistance of a single rebar has been examined. The results indicate that modulated GE arrangement fails to confine the lateral spread of the CE current within a constant area. Using the constant diameter of confinement for the calculation of corrosion rate may lead to serious errors when test conditions change. When high corrosion activity of rebar and/or local corrosion occur, the use of the modulated GE confinement may lead to significant underestimation of the corrosion rate

  10. TEACHING SELF-CONTROL WITH QUALITATIVELY DIFFERENT REINFORCERS

    OpenAIRE

    Passage, Michael; Tincani, Matt; Hantula, Donald A.

    2012-01-01

    This study examined the effectiveness of using qualitatively different reinforcers to teach self-control to an adolescent boy who had been diagnosed with an intellectual disability. First, he was instructed to engage in an activity without programmed reinforcement. Next, he was instructed to engage in the activity under a two-choice fixed-duration schedule of reinforcement. Finally, he was exposed to self-control training, during which the delay to a more preferred reinforcer was initially sh...

  11. On Semiprime Noetherian PI-Rings

    OpenAIRE

    Chiba, Katsuo

    2000-01-01

    Let R be a semiprime Noetherian PI-ring and Q(R) the semisimple Artinian ring of fractions of R. We shall prove the following conditions are equivalent: (1) the Krull dimention of R is at most one, (2) Any ring between R and Q(R) is again right Noetherian, (3) Let a, b be central regular elements of Q(R). Then the subring R + aR[b] of Q(R) is right Noetherian.

  12. PARTIAL REINFORCEMENT (ACQUISITION) EFFECTS WITHIN SUBJECTS.

    Science.gov (United States)

    AMSEL, A; MACKINNON, J R; RASHOTTE, M E; SURRIDGE, C T

    1964-03-01

    Acquisition performance of 22 rats in a straight alley runway was examined. The animals were subjected to partial reinforcement when the alley was black (B+/-) and continuous reinforcement when it was white (W+). The results indicated (a) higher terminal performance, for partial as against continuous reinforcement conditions, for starting-time and running-time measures, and (b) lower terminal performance under partial conditions for a goal-entry-time measure. These results confirm within subjects an effect previously demonstrated, in the runway, only in between-groups tests, where one group is run under partial reinforcement and a separate group is run under continuous reinforcement in the presence of the same external stimuli. Differences between the runway situation, employing a discrete-trial procedure and performance measures at three points in the response chain, and the Skinner box situation, used in its free-operant mode with a single performance measure, are discussed in relation to the present findings.

  13. On zero divisor graph of unique product monoid rings over Noetherian reversible ring

    Directory of Open Access Journals (Sweden)

    Ebrahim Hashemi

    2016-02-01

    Full Text Available Let $R$ be an associative ring with identity and $Z^*(R$ be its set of non-zero zero divisors.  The zero-divisor graph of $R$, denoted by $Gamma(R$, is the graph whose vertices are the non-zero  zero-divisors of  $R$, and two distinct vertices $r$ and $s$ are adjacent if and only if $rs=0$ or $sr=0$.  In this paper, we bring some results about undirected zero-divisor graph of a monoid ring over reversible right (or left Noetherian ring $R$. We essentially classify the diameter-structure of this graph and show that $0leq mbox{diam}(Gamma(Rleq mbox{diam}(Gamma(R[M]leq 3$. Moreover, we give a characterization for the possible diam$(Gamma(R$ and diam$(Gamma(R[M]$, when $R$ is a reversible Noetherian ring and $M$ is a u.p.-monoid. Also, we study relations between the girth of $Gamma(R$ and that of $Gamma(R[M]$.

  14. Imidazolopiperazines (IPZ) kill both rings and dormant rings in wild type and K13 artemisinin resistant Plasmodium falciparum in vitro.

    Science.gov (United States)

    Dembele, Laurent; Gupta, Devendra Kumar; Lim, Michelle Yi-Xiu; Ang, Xiaoman; Selva, Jeremy J; Chotivanich, Kesinee; Nguon, Chea; Dondorp, Arjen M; Bonamy, Ghislain M C; Diagana, Thierry T; Bifani, Pablo

    2018-03-12

    Artemisinin (ART) resistance has spread through Southeast Asia, posing serious threat to the control and elimination of malaria. ART resistance has been associated with mutations in the Plasmodium falciparum kelch-13 ( Pfk13 ) propeller domain. Phenotypically, ART resistance is defined as delayed parasite clearance in patients' due to the reduced susceptibility of early ring-stage parasites to the active metabolite of ART dihydroartemisinin (DHA). Early rings can enter a state of quiescence upon DHA exposure and resume growth in its absence. These quiescent rings are referred to as dormant rings or DHA-pretreated rings (called here dormant rings). The imidazolopiperazine (IPZ) is a novel class of antimalarial drugs, which has demonstrated efficacy in early clinical trials. Here, we characterized the stage of action of IPZ GNF179 and evaluated its activity against rings and dormant rings in wild type and ART resistant parasites. Unlike DHA, GNF179 does not induce dormancy. We show that GNF179 is more rapidly cidal against schizonts than ring and trophozoite stages. However, with 12 hours exposure, the compound effectively kills rings and dormant rings of both susceptible and ART resistant parasites within 72 hours. We further demonstrate that in combination with ART, GNF179 effectively prevent recrudescence of dormant rings including those bearing pfk13 propeller mutations. Copyright © 2018 Dembele et al.

  15. Reinforcement Learning in Repeated Portfolio Decisions

    OpenAIRE

    Diao, Linan; Rieskamp, Jörg

    2011-01-01

    How do people make investment decisions when they receive outcome feedback? We examined how well the standard mean-variance model and two reinforcement models predict people's portfolio decisions. The basic reinforcement model predicts a learning process that relies solely on the portfolio's overall return, whereas the proposed extended reinforcement model also takes the risk and covariance of the investments into account. The experimental results illustrate that people reacted sensitively to...

  16. Complete snake and rotator schemes for spin polarization in proton rings and large electron rings

    International Nuclear Information System (INIS)

    Steffen, K.

    1983-11-01

    In order to maintain spin polarization in proton rings and large electron rings, some generalized Siberian Snake scheme may be required to make the spin tune almost independent of energy and thus avoid depolarizing resonances. The practical problem of finding such schemes that, at reasonable technical effort, can be made to work over large energy ranges has been addressed before and is here revisited in a broadened view and with added new suggestions. As a result, possibly optimum schemes for electron rings (LEP) and proton rings are described. In the proposed LEP scheme, spin rotation is devised such that, at the interaction points, the spin direction is longitudinal as required for experiments. (orig.)

  17. Responding for sucrose and wheel-running reinforcement: effects of sucrose concentration and wheel-running reinforcer duration.

    Science.gov (United States)

    Belke, Terry W; Hancock, Stephanie D

    2003-03-01

    Six male albino rats were placed in running wheels and exposed to a fixed-interval 30-s schedule of lever pressing that produced either a drop of sucrose solution or the opportunity to run for a fixed duration as reinforcers. Each reinforcer type was signaled by a different stimulus. In Experiment 1, the duration of running was held constant at 15 s while the concentration of sucrose solution was varied across values of 0, 2.5. 5, 10, and 15%. As concentration decreased, postreinforcement pause duration increased and local rates decreased in the presence of the stimulus signaling sucrose. Consequently, the difference between responding in the presence of stimuli signaling wheel-running and sucrose reinforcers diminished, and at 2.5%, response functions for the two reinforcers were similar. In Experiment 2, the concentration of sucrose solution was held constant at 15% while the duration of the opportunity to run was first varied across values of 15, 45, and 90 s then subsequently across values of 5, 10, and 15 s. As run duration increased, postreinforcement pause duration in the presence of the wheel-running stimulus increased and local rates increased then decreased. In summary, inhibitory aftereffects of previous reinforcers occurred when both sucrose concentration and run duration varied; changes in responding were attributable to changes in the excitatory value of the stimuli signaling the two reinforcers.

  18. Koffka's Ring Effect Depends on Thickness, Not Continuity

    OpenAIRE

    Abigail E. Huang; Alice J. Hon; Eric L. Altschuler

    2007-01-01

    More than 70 years ago Gestalt psychologist Kurt Koffka described a fascinating effect1,2: When a contiguous grey ring is placed on a background half of one shade of grey (different from the ring) and half of another shade of grey, the ring appears to be a homogenous. However, if the ring is slightly divided, now the two halves of the ring appear different shades of grey with the half of the ring on the darker background appearing lighter than the half of the ring on the darker background. Th...

  19. Rational and Mechanistic Perspectives on Reinforcement Learning

    Science.gov (United States)

    Chater, Nick

    2009-01-01

    This special issue describes important recent developments in applying reinforcement learning models to capture neural and cognitive function. But reinforcement learning, as a theoretical framework, can apply at two very different levels of description: "mechanistic" and "rational." Reinforcement learning is often viewed in mechanistic terms--as…

  20. Conditioned Reinforcement Value and Resistance to Change

    Science.gov (United States)

    Shahan, Timothy A.; Podlesnik, Christopher A.

    2008-01-01

    Three experiments examined the effects of conditioned reinforcement value and primary reinforcement rate on resistance to change using a multiple schedule of observing-response procedures with pigeons. In the absence of observing responses in both components, unsignaled periods of variable-interval (VI) schedule food reinforcement alternated with…