WorldWideScience

Sample records for acetabular labral tear

  1. Acetabular labral tears in patients with sports injury.

    Science.gov (United States)

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  2. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  3. Acetabular labral tears: contrast-enhanced MR imaging under continuous leg traction

    Energy Technology Data Exchange (ETDEWEB)

    Nishii, T. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Nakanishi, K. [Dept. of Radiology, Osaka Univ. Medical School, Suita (Japan); Sugano, N. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan); Naito, H. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Tamura, S. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Ochi, T. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan)

    1996-05-01

    The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning. (orig./MG)

  4. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  5. The preliminary application of magnetic resonance arthrography in the diagnosis of acetabular labrale tears

    International Nuclear Information System (INIS)

    Hong Wen; Zhang Xuezhe; Wang Wu; Yue Debo; Wang Weiguo

    2010-01-01

    Objective: To investigate the application value of MR arthrography (MRA) in the diagnosis of acetabular lab ral tears. Methods: Fifteen patients with a high degree of suspected acetabular lab ral tears received fluoroscope-guided injection of the contrast media into the hip joint (hip arthrography) and fat-saturated spin-echo T 1 -weighted images were obtained in the coronal, sagittal, oblique-axial and radial planes. Hip arthroscopy was performed on 12 of them. Results: Lab ral tears which were diagnosed in 11 patients by hip MRA were confirmed at hip arthroscopy. One patient showed no MRA indication of lab ral tear, also showed normal on arthroscopy. Tear in the anterior-superior quadrant 10 cases of 12 joints (12/13), posterior-superior quadrant 1 case of a joint (1/13). In 11 patients who underwent arthroscopy, hip MRA diagnosed 3 (3/13) joints labrale tears in coronal planes, 10 (10/13) joints in sagittal planes and 13 (13/13) labrale tears in axial-oblique and radial planes. In 15 patients with 20 hip joints, 5 cases 6 joints (6/20) with normal acetabular sublabral sulcus were performed. Conclusions: MR arthrography of hip is a reliable method in the diagnosis of acetabular labrale tears. Scanning method should be included fat-saturated spin-echo T 1 -weighted images in sagittal and oblique-axial planes or sagittal plus radial planes. The diagnosis of torn posterior-inferior quadrant should pay attention to the existence of a normal variation. (authors)

  6. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  7. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    Science.gov (United States)

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Acetabular labral tears with underlying chondromalacia: a possible association with high-level running.

    Science.gov (United States)

    Guanche, Carlos A; Sikka, Robby S

    2005-05-01

    The use of hip arthroscopy has helped delineate intra-articular pathology and has enabled clinicians to further elucidate the factors responsible for injuries, such as running. The subtle development of degenerative changes may be a result of repetitive impact loading associated with this sport. This study presents a population of runners with common pathologic acetabular changes. Case series. Eight high-level runners with an average age of 36 years (range, 19 to 45 years) were seen for complaints of increasing hip pain with running without any history of macrotrauma. All of the patients had either run several marathons (4), were triathletes (1), Olympic middle distance runners (1), or had run more than 10 miles per week for longer than 5 years (2). Plain radiographic analysis revealed no degenerative changes and an average center-edge (CE) angle of 36.7 degrees (range, 28 degrees to 44 degrees). All patients underwent hip arthroscopy with labral debridement. In 6 patients (75%), a chondral injury of the acetabular cartilage underlying the labral tear was noted. In addition, 3 patients had ligamentum teres disruptions. It is possible that the development of these tears is the result of subtle instability, which may be exacerbated by running, eventually leading to labral tearing and possible ligamentum teres disruption. While perhaps concurrently, subtle acetabular dysplasia may play a role. Although this study does not confirm an association between running and the development of labral tears or chondral lesions in the hip, it certainly questions whether there is an injury pattern common to this population, a "runner's hip." Level IV.

  9. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  10. Magnetic resonance arthrography and the prevalence of acetabular labral tears in patients 50 years of age and older

    International Nuclear Information System (INIS)

    Jayakar, Rohit; Merz, Alexa; Wang, Dean; Hame, Sharon L.; Plotkin, Benjamin; Seeger, Leanne

    2016-01-01

    Arthroscopy for acetabular labral tears has minimal impact on pain and function in older patients, especially in the setting of concomitant osteoarthritis. Still, many physicians seek this diagnosis with MR arthrography. Our purpose is to assess the frequency of acetabular labral tears in older patients with hip pain and correlate likelihood of labral pathology with severity of osteoarthritis as visualized on conventional radiograph. From 2004 to 2013, 208 hip MRI arthrograms and corresponding radiographs on patients aged 50 years and older were identified. Age, gender, grade and location of labral tear, alpha angle, Toennis grade, and joint space width were documented. Labral tears and alpha angle were identified and measured on MR arthrogram. Toennis grade and joint space width were measured on radiographs. On MR arthrography, true labral tearing was identified in 73 % of patients. There was some degree of labral pathology in 93.3 % of patients, and this increased to 100 % in patients with moderate to severe osteoarthritis, as defined by Toennis grade 2-3 or joint space width ≤ 2 mm. There were no statistically significant correlations between labral tear grade and Toennis grade or joint space width. Given the high frequency of labral pathology and the questionable efficacy of arthroscopic surgical intervention in older patients, MR arthrography should be primarily for those with minimal arthritis on radiograph and potential to benefit from surgery. If further imaging beyond radiographs is necessary in these patients, standard MRI may be a more appropriate imaging tool. (orig.)

  11. Similar Prevalence of Acetabular Labral Tear in Professional Ballet Dancers and Sporting Participants.

    Science.gov (United States)

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2016-07-01

    To compare the prevalence of acetabular labral tear in male and female professional ballet dancers with age-matched and sex-matched sporting participants and to determine the relationship to clinical findings and cartilage defects. Case-control study. Clinical and radiology practices. Forty-nine (98 hips) male and female professional ballet dancers (current and retired) with median age 30 years (range: 19-64 years) and 49 (98 hips) age-matched and sex-matched sporting participants. Group (ballet or sports), sex, age, hip cartilage defects, history of hip pain, Hip and Groin Outcome Score, passive hip internal rotation (IR), and external rotation range of movement (ROM). Labral tear identified with 3T magnetic resonance imaging (MRI). Labral tears were identified in 51% of all 196 hips. The prevalence did not differ significantly between the ballet and sporting participants (P = 0.41) or between sexes (P = 0.34). Labral tear was not significantly associated with clinical measures, such as pain and function scores or rotation ROM (P > 0.01 for all). Pain provocation test using IR at 90° of hip flexion had excellent specificity [96%, 95% confidence intervals (CIs), 0.77%-0.998%] but poor sensitivity (50%, 95% CI, 0.26%-0.74%) for identifying labral tear in participants reporting hip pain. Older age and cartilage defect presence were independently associated with an increased risk of labral tear (both P ballet dancers was similar to a sporting population. Labral tears were not associated with clinical findings but were related to cartilage defects, independent of aging. Caution is required when interpreting MRI findings as labral tear may not be the source of the ballet dancer's symptoms.

  12. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    International Nuclear Information System (INIS)

    Aly, Abdel Rahman; Rajasekaran, Sathish; Obaid, Haron

    2013-01-01

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  13. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Abdel Rahman [University of Saskatchewan, Department of Physical Medicine and Rehabilitation, Saskatoon, SK (Canada); Saskatoon City Hospital, Saskatoon, SK (Canada); Rajasekaran, Sathish [HealthPointe, Pain, Spine and Sport Medicine, Alberta (Canada); Obaid, Haron [Royal University Hospital, University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada)

    2013-09-15

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  14. Classification and localization of acetabular labral tears

    International Nuclear Information System (INIS)

    Blankenbaker, D.G.; De Smet, A.A.; Keene, J.S.; Fine, J.P.

    2007-01-01

    The purpose of this study was to compare the findings on hip MR arthrography (MRA) with the published MRA and arthroscopic classifications of hip labral tears and to evaluate a clock-face method for localizing hip labral tears. We retrospectively reviewed 65 hip MRA studies with correlative hip arthroscopies. Each labrum was evaluated on MRA using the classification system of Czerny and an MRA modification of the Lage arthroscopic classification. In addition, each tear was localized on MRA by using a clock-face description where 6 o'clock was the transverse ligament and 3 o'clock was anterior. These MRA findings were then correlated with the arthroscopic findings using the clock-face method of localization and the Lage arthroscopic classification of labral tears. At MRA, there were 42 Czerny grade 2 and 23 grade 3 labral tears and 22 MRA Lage type 1, 11 type 2, 22 type 3 and 10 type 4 tears. At arthroscopy, there were 10 Lage type 1 flap tears, 20 Lage type 2 fibrillated tears, 18 Lage type 3 longitudinal peripheral tears and 17 Lage type 4 unstable tears. The Czerny MRA classification and the modified MRA Lage classification had borderline correlation with the arthroscopic Lage classification. Localization of the tears using a clock-face description was within 1 o'clock of the arthroscopic localization of the tears in 85% of the patients. The Lage classification, which is the only published arthroscopic classification system for hip labral tears, does not correlate well with the Czerny MRA or an MRA modification of the Lage classification. Using a clock-face description to localize tears provides a way to accurately localize a labral tear and define its extent. (orig.)

  15. The diagnostic value of direct CT arthrography using MDCT in the evaluation of acetabular labral tear: with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yong-Chan; Kim, Jae Yoon [Chung-Ang University College of Medicine, Department of Orthopaedic Surgery, Seoul (Korea, Republic of); Choi, Jung-Ah; Lee, Guen Young; Kang, Heung Sik [Seoul National University Bundang Hospital, Departments of Radiology, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam (Korea, Republic of); Lee, Young-Kyun; Koo, Kyung-Hoi [Seoul National University Bundang Hospital, Orthopaedic Surgery, Seoul National University College of Medicine, Seongnam (Korea, Republic of)

    2013-05-15

    The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization. Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons. Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p = 0.013). Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear. (orig.)

  16. Hip flexor muscle size, strength and recruitment pattern in patients with acetabular labral tears compared to healthy controls.

    Science.gov (United States)

    Mendis, M Dilani; Wilson, Stephen J; Hayes, David A; Watts, Mark C; Hides, Julie A

    2014-10-01

    Acetabular labral tears are a source of hip pain and are considered to be a precursor to hip osteoarthritis. Hip flexor muscles contribute to hip joint stability and function but it is unknown if their size and function is altered in the presence of labral pathology. This study aimed to investigate hip flexor muscle size, strength and recruitment pattern in patients with hip labral pathology compared to control subjects. 12 subjects diagnosed with an unilateral acetabular labral tear were compared to 12 control subjects matched for age and gender. All subjects underwent magnetic resonance imaging (MRI) of their lumbo-pelvic region. Average muscle cross-sectional area (CSA) of the iliacus, psoas, iliopsoas, sartorius, tensor fascia latae and rectus femoris muscles were measured. Hip flexion strength was measured by an externally fixed dynamometer. Individual muscle recruitment pattern during a resisted hip flexion exercise task was measured by muscle functional MRI. Hip flexor muscle strength was found to be decreased in patients with labral pathology compared to control subjects (p muscle size (all p > 0.17) and recruitment pattern (all p > 0.53). Decreased hip flexor muscle strength may affect physical function in patients with hip labral pathology by contributing to altered gait patterns and functional tasks. Clinical rehabilitation of these patients may need to include strengthening exercises for the hip flexor muscles. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Diagnostic accuracy of clinical tests for the diagnosis of hip femoroacetabular impingement/labral tear

    DEFF Research Database (Denmark)

    Reiman, M P; Goode, A P; Cook, C E

    2015-01-01

    BACKGROUND: Surgery for hip femoroacetabular impingement/acetabular labral tear (FAI/ALT) is exponentially increasing despite lacking investigation of the accuracy of various diagnostic measures. Useful clinical utility of these measures is necessary to support diagnostic imaging and subsequent...

  18. The hip fluid seal--Part II: The effect of an acetabular labral tear, repair, resection, and reconstruction on hip stability to distraction.

    Science.gov (United States)

    Nepple, Jeffrey J; Philippon, Marc J; Campbell, Kevin J; Dornan, Grant J; Jansson, Kyle S; LaPrade, Robert F; Wijdicks, Coen A

    2014-04-01

    The acetabular labrum is theorized to be important to normal hip function by providing stability to distraction forces through the suction effect of the hip fluid seal. The purpose of this study was to determine the relative contributions of the hip capsule and labrum to the distractive stability of the hip, and to characterize hip stability to distraction forces in six labral conditions: intact labrum, labral tear, labral repair (looped vs. through sutures), partial resection, labral reconstruction with iliotibial band, and complete resection. Eight cadaveric hips with a mean age of 47.8 years (SD 4.3, range 41-51 years) were included. For each condition, the hip seal was broken by distracting the hip at a rate of 0.33 mm/s while the required force, energy, and negative intra-articular pressure were measured. For comparisons between labral conditions, measurements were normalized to the intact labral state (percent of intact). The relative contribution of the labrum to distractive stability was greatest at 1 and 2 mm of displacement, where it was significantly greater than the role of the capsule and accounted for 77 % (SD 27 %, p = 0.006) and 70 % (SD 7 %, p = 0.009) of total distractive stability, respectively. The relative contribution of the capsule to distractive stability increased with progressive displacement, providing 41 % (SD 49 %) and 52 % (SD 53 %) of distractive stability at 3 and 5 mm of distraction, respectively. The maximal distraction force required to break the hip seal in the intact labral state (capsule removed) varied from 124 to 150 N. Labral tear, partial resection, and complete resection resulted in average maximal distraction forces of 76 % (SD 34 %), 29 % (SD 26 %), and 27 % (SD 22 %), respectively, compared to the intact state. Through type labral repairs resulted in significantly greater improvements (from the labral tear state) in maximal negative pressure generated, compared to looped type repairs (median increase; +32 vs. -9 %, p

  19. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear

    DEFF Research Database (Denmark)

    Reiman, Michael P.; Thorborg, Kristian; Goode, Adam P.

    2017-01-01

    Background: Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Purpose: Summarize and evaluate the diagnostic...... probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings...... decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Clinical Relevance: Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis...

  20. Hip Labral Tear

    Science.gov (United States)

    ... that joint in the future. Prevention Hip labral tears are often associated with sports participation. If your sport puts a lot of strain on your hips, condition the surrounding muscles with strength and flexibility exercises. Try to avoid ...

  1. Achados em ressonância magnética artrográfica de indivíduos com lesão do labrum acetabular Magnetic resonance arthrographic findings in subjects with acetabular labral tears

    Directory of Open Access Journals (Sweden)

    André Luiz Almeida Pizzolatti

    2011-01-01

    Full Text Available OBJETIVO: Descrever os achados em artro RM de sujeitos com suspeita de lesão do labrum acetabular. MÉTODO: Foram analisadas 108 artro RM de quadris em 2007/2008. Dois radiologistas independentemente analisaram as imagens e foi considerada a resposta comum entre eles. Com base em seus pareceres observou-se o local e estadiamento das lesões labrais e condrais, as alterações anatômicas, e a presença de tendinite e bursite trocantérica. RESULTADO: As lesões labrais grau I ocorreram em 41% dos casos, grau II em 31%, e grau III em 29%. O IFA tipo cam foi frequente em 36% dos casos, tipo pincer em 11%, e IFA misto em 13%, nestes casos 57% apresentaram lesão labral grau III, A lesão condral grau I foi observada em 51% acetábulos, as de grau II em 13%, e grau III em 18%. CONCLUSÃO: As alterações morfológicas que provocam IFA do tipo cam foram as mais prevalentes. Em relação ao grau de lesão labral e condral foram predominantes as lesões grau I independente da presença ou do tipo de IFA, exceto em IFAs mistos onde houve predomínio de lesão labral grau III. Não foi observada uma relação entre o grau de lesão labral e condral.OBJECTIVE: To describe the MR arthrographic findings in subjects with suspected acetabular labral tears of the hip. METHOD: 108 hip MRa results were analyzed in 2007-2008. Two radiologists independently interpreted the images, and the consensual answers between them were considered for analysis. Based on their opinions, information was obtained on the location, staging of the chondral and labral lesions, anatomic alterations, and the presence of trochanteric bursitis and tendonitis. RESULTS: 1st degree labral lesions occurred in 41% of cases, 2nd degree in 31%, and 3rd degree in 29%. The cam type FAI was common in 36% of cases, pincer FAI in 11%, and mixed cam-pincer FAI in 13%; in these cases 57% had grade III labral lesions. 1st degree chondral lesions were observed in 51% of acetabulum, 2nd degree in 13

  2. MR imaging appearance of 180-360 labral tears of the shoulder

    International Nuclear Information System (INIS)

    Lindauer, Kelly R.; Major, Nancy M.; Rougier-Chapman, Duncan P.; Helms, Clyde A.

    2005-01-01

    Glenoid labral tears exceeding 180 are an uncommon entity in which characteristic clinical and MR imaging features can lead to a more accurate preoperative diagnosis. We provide a description of glenoid labral tears that exceed 180 , and their characteristic magnetic resonance imaging features. In the young, heavily muscled male athlete, the identification of multiple sites of labral pathology and isolated, extensive posterior labral injuries are features that should raise suspicion for labral tears that exceed 180 . (orig.)

  3. Acetabular paralabral cyst: an uncommon cause of sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, P.M.; Sanders, T.G. [Department of Radiology, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States); Matchette, M.W. [University of Texas Medical School, 7703 Floyd Curl Drive, San Antonio, TX 78229-3900 (United States); Parsons, T.W. [Department of Orthopedic Surgery, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States)

    2003-02-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  4. Acetabular paralabral cyst: an uncommon cause of sciatica

    International Nuclear Information System (INIS)

    Sherman, P.M.; Sanders, T.G.; Matchette, M.W.; Parsons, T.W.

    2003-01-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  5. Evaluation of Labral Pathology and Hip Articular Cartilage in Patients with Femoroacetabular Impingement (FAI): Comparison of Multidetector CT Arthrography and MR Arthrography

    International Nuclear Information System (INIS)

    Sahin, Murat; Calisir, Cuneyt; Omeroglu, Hakan; Inan, Ulukan; Mutlu, Fezan; Kaya, Tamer

    2014-01-01

    To compare the multidetector computed tomography (MDCT) arthrography (CTa) and magnetic resonance (MR) arthrography (MRa) findings with surgical findings in patients with femoroacetabular impingement (FAI) and to evaluate the diagnostic performance of these methods. Labral pathology and articular cartilage were prospectively evaluated with MRa and CTa in 14 hips of 14 patients. The findings were evaluated by two musculoskeletal radiologists with 10 and 20 years of experience, respectively. Sensitivity, specificity, accuracy, and positive predictive value were determined using surgical findings as the standard of reference. While the disagreement between observers was recorded in two cases of labral tearing with MRa, there was a complete consensus with CTa. Disagreement between observers was found in four cases of femoral cartilage loss with both MRa and CTa. Disagreement was also recorded in only one case of acetabular cartilage loss with both methods. The percent sensitivity, specificity, and accuracy for correctly assessing the labral tearing were as follows for MRa/CTa, respectively: 100/100, 50/100, 86/100 (p<0.05). The same values for acetabular cartilage assessment were 89/56, 40/60, 71/71 (p>0.05) and for femoral cartilage assessment were 100/75, 90/70, 86/71 (p>0.05). Inter-observer reliability value showed excellent agreement for labral tearing with CTa (κ=1.0). Inter-observer agreement was substantial to excellent with regard to acetabular cartilage assessment with MRa and CTa (κ=0.76 for MRa and κ=0.86 for CTa) Inter-observer reliability with CTa is excellent for labral tearing assessment. CTa seems to have an equal sensitivity and a higher specificity than MRa for the detection of labral pathology. MRa is better, but not statistically significantly, in demonstrating acetabular and femoral cartilage pathology

  6. recurrent traumatic posterior hip dislocation in labral avulsion

    African Journals Online (AJOL)

    2003; 54(3):520-529. 5. Dameron, T.B Jr. Bucket-handle tear of acetabular labrum accompanying posterior dislocation of the hip. J Bone Joint Surg Am. 1959; 41(1): 131-134. 6. Lieberman, J.R., Altchek, D.W. and Salvati,. E.A. Recurrent dislocation of a hip with a labral lesion: treatment with a modified Bankart-type repair.

  7. Anterior labral tear: diagnostic value of MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Yoon, Yeong Cheol; Ryu, Kyung Nam; Rhee, Yong Girl

    2001-01-01

    To assess the accuracy of magnetic resonance(MR) arthrography in the diagnosis of anterior labral tear of the shoulder Between september 1996 and February 2000, MR arthrography of the shoulder was performed in 281 patients with a history of shoulder pain or instability. Among this total, only 157 shoulders in 154 patients who underwent arthroscopy or open surgery 0 to 230 (average, 20.9) days after MR arthrography were included in this study; the subjects comprised of 150 males and 4 females with an average age of 23.3 years. MR arthrographs of these 154 patients were analyzed for the presence of anterior labral tears, and the findings were correlated with the arthroscopic and surgical findings. Anterior labral tear was classified as A to D according to its location, as determined by arthroscopy and surgery. (A=4 to 6 o'clock direction, anteroinferior; B=2 to 4 o'clock direction, central; C=12 to 2 o'clock direction, anterosuperior; D= SLAP lesion). The retrospective analysis of MR arthrographs showing false-positive and negative findings was also underthken.. In the diagnosis of anterior labral tear, MR arthrography showed a sensitivity of 94%, a specificity of 90% and an accuracy of 91%. Anterior labral tears were confirmed by arthroscopy or surgery in 62 of the 157 shoulders (39%). Among 62 lesion, two (3%) were observed in area A, 32(52%) in area A+B, nine (15%) in area A+B+C, one(2%) in area A+B+D,13(21%) in area A+B+C+D, two (3%) in area B+C, one(2%) in area B+D, and two(3%) in area C. Among ten false-positive cases, seven were focal lessions (two, three and two lesions in area A, B and C, respectively), and in the remaining three cases, lacated in area A+B, MR arthrography revealed thickening and deformation. All four false negatives were focal lesions (two in area A and two in area C). Other than in focal lesions, in which accuracy was relatively low, MR arthrography showed high sensitivity, specificity and accuracy in the diagnosis of anterior labral tear

  8. Diagnosis of lesions of the acetabular labrum, of the labral-chondral transition zone, and of the cartilage in femoroacetabular impingement: Correlation between direct magnetic resonance arthrography and hip arthroscopy.

    Science.gov (United States)

    Crespo Rodríguez, A M; de Lucas Villarrubia, J C; Pastrana Ledesma, M A; Millán Santos, I; Padrón, M

    2015-01-01

    To determine the sensitivity and accuracy of direct MR arthrography in the diagnosis of intra-articular lesions associated with femoroacetabular impingement. We used direct MR arthrography to study 51 patients with femoroacetabular impingement who underwent arthroscopic hip surgery. Surgery demonstrated 37 labral tears, 44 lesions in the labral-chondral transitional zone, and 40 lesions of the articular cartilage. We correlated the findings at preoperative direct MR arthrography with those of hip arthroscopy and calculated the sensitivity, specificity, positive predictive value, negative predictive value, and validity index for direct MR arthrography. The sensitivity and specificity of MR arthrography were 94.5% and 100%, respectively, for diagnosing labral tears, 100% and 87.5%, respectively, for diagnosing lesions of the labral-chondral transition zone, and 92.5% and 54.5%, respectively, for diagnosing lesions of the articular cartilage. The negative predictive value of MR arthrography for lesions of the labral-chondral transitional zone was 100%. MR arthrography accurately defined extensive lesions of the cartilage and the secondary osseous changes (the main factor in poor prognosis), although its diagnostic performance was not so good in small chondral lesions. In patients with femoroacetabular impingement, direct MR arthrography can adequately detect and characterize lesions of the acetabular labrum and of the labral-chondral transitional zone as well as extensive lesions of the articular cartilage and secondary osseous changes. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  9. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Jessica K.; Vinson, Emily N. [Duke University Hospital, Department of Radiology, Durham, NC (United States); Taylor, Dean C. [Duke University Hospital, Department of Orthopaedic Surgery, Durham, NC (United States)

    2017-08-15

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  10. Magnetic resonance imaging and clinical features of glenoid labral flap tears

    International Nuclear Information System (INIS)

    Stewart, Jessica K.; Vinson, Emily N.; Taylor, Dean C.

    2017-01-01

    Displaced flaps of glenoid labral tissue are an uncommonly encountered finding on MRI of the shoulder, and are of unclear clinical significance. The purpose of this study is to describe the imaging characteristics of displaced glenoid labral flaps, evaluate for any common concomitant injuries, and identify the typical clinical presentation and management of patients with this lesion. This retrospective, observational study was approved by the institutional review board. Nineteen patients with flap-type tears of the labrum on preoperative MRI were identified. Each examination was retrospectively reviewed by two radiologists for size, location, and signal intensity of the displaced flap of tissue, in addition to any co-existing labrum or cartilage pathological conditions and clinical information. All displaced flaps extended from the inferior margin of the glenoid into the axillary recess. The average size of the visualized flap was 10.9 by 6.0 by 2.6 mm. Seventy percent of the flaps had signal intensity isointense to labrum and hypointense to hyaline cartilage on T2-weighted images. All 19 patients had concomitant labral pathological conditions and 63% had cartilage defects, visualized on MRI. Clinical evidence of shoulder instability was seen in 83% of patients, and 67% were managed surgically. Glenoid labral flap tears have distinct imaging characteristics that may aid in their identification. Their presence should prompt careful evaluation of the glenoid articular cartilage. Recognition of a labral flap tear may have clinical importance, as 83% of patients with this finding demonstrated clinical evidence of shoulder instability, often requiring surgical intervention. (orig.)

  11. Effect of centre-edge angle on clinical and quality of life outcomes after arthroscopic acetabular labral debridement.

    Science.gov (United States)

    Wu, Ziying; Chen, Shiyi; Li, Yunxia; Li, Hong; Chen, Jiwu

    2016-07-01

    The aim of this study was to compare clinical and quality of life outcomes following arthroscopic acetabular labral debridement between patients with different centre-edge (CE) angle. A total of 79 patients who underwent hip labral debridement were enrolled in this study. Radiographic measurements of CE angle were collected, and patients were assigned into a normal group (25°  0.05). Additionally, there was a greater improvement in clinical scores post-operatively in the normal group compared with the dysplasia group (P 25° compared with patients with CE angle < 20°.

  12. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan; Lee, Sung Ah

    2007-01-01

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US

  13. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan [Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Sung Ah [Seoul Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US.

  14. Three-dimensional magnetic resonance imaging analysis of hip morphology in the assessment of femoral acetabular impingement

    International Nuclear Information System (INIS)

    Kavanagh, E.C.; Read, P.; Carty, F.; Zoga, A.C.; Parvizi, J.; Morrison, W.B.

    2011-01-01

    Aim: To determine a possible association between femoral-acetabular impingement (FAI) volume and the development of labral tear using a three-dimensional (3D) model reconstruction of the acetabulum and the femoral head. Materials and methods: Magnetic resonance arthrography images of the hip in 42 patients with pain and suspected labral tear were acquired using a 1.5 T MRI machine. Using 3D analysis software, outlines of the acetabular cup and femoral head were drawn and 3D reconstruction obtained. To control for differences in patient size, ratios of acetabulum : femoral head volume (AFV) and acetabulum : femoral head surface area (AFA) were used for analysis. The association between volume of acetabulum : femoral head and FAI was investigated using ANOVA analysis. Results: There were 19 men and 23 women with a mean age of 39 years (range 18-78 years). The average AFV was 0.64 (range 0.37-1.05, SD 0.16) and AFA was 0.73 (range 0.36-1.26, SD 0.23). Herniation pit was significantly associated with a small AFV. Conclusion: Femoral neck herniation pits are associated with a low AFV. Gross volume and surface area ratios do not appear to correlate with labral tears or cartilage loss. This technique will enable more advanced analysis of morphological variations associated with FAI.

  15. Reliability and diagnostic accuracy of history and physical examination for diagnosing glenoid labral tears.

    Science.gov (United States)

    Walsworth, Matthew K; Doukas, William C; Murphy, Kevin P; Mielcarek, Billie J; Michener, Lori A

    2008-01-01

    Glenoid labral tears provide a diagnostic challenge. Combinations of items in the patient history and physical examination will provide stronger diagnostic accuracy to suggest the presence or absence of glenoid labral tear than will individual items. Cohort study (diagnosis); Level of evidence, 1. History and examination findings in patients with shoulder pain (N = 55) were compared with arthroscopic findings to determine diagnostic accuracy and intertester reliability. The intertester reliability of the crank, anterior slide, and active compression tests was 0.20 to 0.24. A combined history of popping or catching and positive crank or anterior slide results yielded specificities of 0.91 and 1.00 and positive likelihood ratios of 3.0 and infinity, respectively. A positive anterior slide result combined with either a positive active compression or crank result yielded specificities of 0.91 and positive likelihood ratio of 2.75 and 3.75, respectively. Requiring only a single positive finding in the combination of popping or catching and the anterior slide or crank yielded sensitivities of 0.82 and 0.89 and negative likelihood ratios of 0.31 and 0.33, respectively. The diagnostic accuracy of individual tests in previous studies is quite variable, which may be explained in part by the modest reliability of these tests. The combination of popping or catching with a positive crank or anterior slide result or a positive anterior slide result with a positive active compression or crank test result suggests the presence of a labral tear. The combined absence of popping or catching and a negative anterior slide or crank result suggests the absence of a labral tear.

  16. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    International Nuclear Information System (INIS)

    Jakanani, G.C.; Botchu, R.; Rennie, W.J.

    2012-01-01

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p ≤ 0.04) and also between a type 2 attachment and SLAP tears (p ≤ 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  17. The MR arthrographic anatomy of the biceps labral insertion and its morphological significance with labral tears in patients with shoulder instability

    Energy Technology Data Exchange (ETDEWEB)

    Jakanani, G.C., E-mail: gcjakanani@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Botchu, R., E-mail: drrajeshb@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom); Rennie, W.J., E-mail: winston.rennie@gmail.com [Leicester Royal Infirmary, Leicester (United Kingdom)

    2012-11-15

    Introduction: Most of the fibres of the long head of biceps tendon attach on the superior labrum just posterior to the supraglenoid tubercle. Aim: Our hypothesis was that posteriorly attached biceps tendons predispose to posterior superior labral tears and SLAP lesions. Methods and materials: A prospective analysis of all MR shoulder arthrograms for shoulder instability referred from the shoulder specialist clinics, performed during a one year period were reviewed by two independent observers who were blinded to clinical history. The biceps attachment was classified into four groups according to the method described in an earlier cadaveric study into four groups; posterior-type 1, predominantly posterior-type 2, equal contributions to both anterior and posterior labrum-type 3 and predominantly anterior labral attachment-type 4. Data was analysed using Kappa statistics and Fischer's exact test. Results: 48 patients (33 males and 15 females) were included in this study with a mean age of 32 years. Majority, 22 patients (46%) had a type 1 attachment of the biceps on the superior labrum. There was moderate intra-observer and good interobserver agreement with a Kappa of 0.58 and 0.63 respectively. There was a significant association between a type 2 attachment and posterior tears (p {<=} 0.04) and also between a type 2 attachment and SLAP tears (p {<=} 0.04). Conclusion: Our results suggest that variation in anatomy of biceps origin influences the type of labral tears that occur in patients with shoulder instability. The importance of these findings could influence selection of individuals in throwing sports like cricket and baseball.

  18. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    Science.gov (United States)

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  19. Magnetic resonance imaging evaluation of meniscoid superior labrum: normal variant or superior labral tear

    Directory of Open Access Journals (Sweden)

    Marcelo Novelino Simão

    Full Text Available Abstract Objective: The objective of this study was to determine the incidence of a "meniscoid" superior labrum. Materials and Methods: This was a retrospective analysis of 582 magnetic resonance imaging examinations of shoulders. Of those 582 examinations, 110 were excluded, for a variety of reasons, and the final analysis therefore included 472 cases. Consensus readings were performed by three musculoskeletal radiologists using specific criteria to diagnose meniscoid labra. Results: A meniscoid superior labrum was identified in 48 (10.2% of the 472 cases evaluated. Arthroscopic proof was available in 21 cases (43.8%. In 10 (47.6% of those 21 cases, the operative report did not include the mention a superior labral tear, thus suggesting the presence of a meniscoid labrum. In only one of those cases were there specific comments about a mobile superior labrum (i.e., meniscoid labrum. In the remaining 11 (52.4%, surgical correlation demonstrated superior labral tears. Conclusion: A meniscoid superior labrum is not an infrequent finding. Depending upon assumptions and the requirement of surgical proof, the prevalence of a meniscoid superior labrum in this study was between 2.1% (surgically proven and 4.8% (projected. However, superior labral tears are just as common and are often confused with meniscoid labra.

  20. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear: A Systematic Review With Meta-analysis.

    Science.gov (United States)

    Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per

    2017-09-01

    Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US

  1. The role of the acetabular labrum in hip dysplasia

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Søballe, Kjeld; Troelsen, Anders

    2013-01-01

    A periacetabular osteotomy (PAO) is the preferred joint preserving treatment for young adults with symptomatic hip dysplasia and no osteoarthritis. In symptomatic dysplasia of the hip, there is labral pathology in up to 90% of cases. However, no consensus exists as to whether a labral tear should...... be treated before the periacetabular osteotomy (PAO), treated simultaneously with the PAO, or left alone and only treated if symptoms persist after the PAO. This review is an update of aspects of labral anatomy and function, the etiology of labral tears in hip dysplasia, and diagnostic assessment of labral...... tears, and we discuss treatment strategies for coexisting labral tears and hip dysplasia....

  2. Diagnosis of glenoid labral tears using 3-tesla MRI vs. 3-tesla MRA: a systematic review and meta-analysis.

    Science.gov (United States)

    Ajuied, Adil; McGarvey, Ciaran P; Harb, Ziad; Smith, Christian C; Houghton, Russell P; Corbett, Steven A

    2018-05-01

    Various protocols exist for magnetic resonance arthrogram (MRA) of the shoulder, including 3D isotropic scanning and positioning in neutral (2D neutral MRA), or abduction-external-rotation (ABER). MRA does not improve diagnostic accuracy for labral tears when compared to magnetic resonance imaging (MRI) performed using 3-Tesla (3T) magnets. Systematic review of the Cochrane, MEDLINE, and PubMed databases according to PRISMA guidelines. Included studies compared 3T MRI or 3T MRA (index tests) to arthroscopic findings (reference test). Methodological appraisal performed using QUADAS-2. Pooled sensitivity and specificity were calculated. Ten studies including 929 patients were included. Index test bias and applicability were a concern in the majority of studies. The use of arthroscopy as the reference test raised concern of verification bias in all studies. For anterior labral lesions, 3T MRI was less sensitive (0.83 vs. 0.87 p = 0.083) than 3T 2D neutral MRA. Compared to 3T 2D neutral MRA, both 3T 3D Isotropic MRA and 3T ABER MRA significantly improved sensitivity (0.87 vs. 0.95 vs. 0.94). For SLAP lesions, 3T 2D neutral MRA was of similar sensitivity to 3T MRI (0.84 vs. 0.83, p = 0.575), but less specific (0.99 vs. 0.92 p < 0.0001). For posterior labral lesions, 3T 2D neutral MRA had greater sensitivity than 3T 3D Isotropic MRA and 3T MRI (0.90 vs. 0.83 vs. 0.83). At 3-T, MRA improved sensitivity for diagnosis of anterior and posterior labral lesions, but reduced specificity in diagnosis of SLAP tears. 3T MRA with ABER positioning further improved sensitivity in diagnosis of anterior labral tears. IV.

  3. How often do surgeons intervene on shoulder labral lesions detected at MR examination? A retrospective review of MR examinations correlated with arthroscopy

    Science.gov (United States)

    2014-01-01

    Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320

  4. Comparison between 3D isotropic and 2D conventional MR arthrography for diagnosing rotator cuff tear and labral lesions: A meta-analysis.

    Science.gov (United States)

    Lee, Sun Hwa; Yun, Seong Jong; Jin, Wook; Park, So Young; Park, Ji Seon; Ryu, Kyung Nam

    2018-03-30

    Although 3D-isotropic MR arthrography has been characterized as a substitute imaging tool for rotator cuff tear (RCT) and labral lesions, it has not been commonly used in clinical practice because of controversy related to image blurring and indistinctness of structural edges. To perform a comparison of the diagnostic performance of 3D-isotropic MR arthrography and 2D-conventional MR arthrography for diagnosis of RCT (solely RCT, full/partial-thickness supraspinatus [SST]-infraspinatus [IST] tear, or subscapularis [SSc] tear) and labral lesions. Meta-analysis. Patients with shoulder pain. 3D-isotropic and 2D-conventional MR arthrography at 3.0T or 1.5T. PubMed and EMBASE were searched following the PRISMA guidelines. Bivariate modeling and hierarchical summary receiver operating characteristic modeling were performed to compare the overall diagnostic performance of 3D-isotropic and 2D-conventional MR arthrography. Multiple-subgroup analyses were performed for diagnosing RCT, full/partial-thickness SST-IST tear, SSc tear, and labral lesions. Meta-regression analyses were performed according to subject, study, and MR arthrography characteristics including 3D-isotropic sequences (turbo spine echo [TSE] vs. gradient echo [GRE]). Eleven studies (825 patients) were included. Overall, 3D-isotropic MR arthrography had similar pooled sensitivity (0.90 [95% CI, 0.87-0.93]) (P = 0.95) and specificity (0.92 [95% CI, 0.87-0.95]) (P = 0.99), relative to 2D-conventional MR arthrography (sensitivity, 0.91 [95% CI, 0.86-0.94]); specificity, 0.92 [95% CI, 0.87-0.95]). Multiple-subgroup analyses showed that sensitivities (P = 0.13-0.91) and specificities (P = 0.26-0.99) on 3D-isotropic MR arthrography for diagnosing RCT, full/partial-thickness SST-IST tear, SSC tear, and labral lesions were not significantly different from 2D-conventional MR arthrography. On meta-regression analysis, 3D-TSE sequence demonstrated higher sensitivity (P 3D-GRE for RCT and labral

  5. MR imaging findings of acetabular dysplasia in adults

    Energy Technology Data Exchange (ETDEWEB)

    James, Steven; Connell, David [The Royal National Orthopaedic Hospital, Radiology Department, London, Middlesex (United Kingdom); Miocevic, Miranda; Malara, Frank; Pike, Jonathan [Victoria House Hospital, Radiology Department, Melbourne (Australia); Young, David [Melbourne Orthopaedic Group, Orthopaedic Surgery, Melbourne (Australia)

    2006-06-15

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  6. MR imaging findings of acetabular dysplasia in adults

    International Nuclear Information System (INIS)

    James, Steven; Connell, David; Miocevic, Miranda; Malara, Frank; Pike, Jonathan; Young, David

    2006-01-01

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  7. Magnetic resonance imaging of labral cysts of the hip

    International Nuclear Information System (INIS)

    Schnarkowski, P.; Steinbach, L.S.; Tirman, P.F.J.; Peterfy, C.G.; Genant, H.K.

    1996-01-01

    Objective. To present the magnetic resonance (MR) imaging findings in patients with labral cysts adjacent to the acetabulum and to examine their association with hip pathology. Design. MR images and conventional radiographs of seven patients with paralabral cysts were retrospectively reviewed by three musculoskeletal radiologists. Patients. The patients included three men and four women with hip pain, ranging in age from 29 to 82 years. Two patients had developmental dysplasia of the hip and six had a history of remote trauma/dislocation. Clinical history and follow-up were obtained in all patients. Surgery was performed on one patient. Results and conclusions. Paralabral cysts were located in the posterosuperior aspect of the hip joint in five patients and in the anterior aspect in two patients. A tear of the adjacent acetabular labrum was confirmed surgically in one patient, and in all patients the MR features suggested the presence of an abnormal labrum. Osteoarthritis was observed in three patients and there was associated subchondral cyst formation in the acetabulum adjacent to the cyst in three patients. The paralabral cyst of the hip is well visualized on MR imaging and is seen in patients with a predisposition to labral pathology. (orig.). With 3 figs., 1 tab

  8. Magnetic resonance imaging of labral cysts of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Schnarkowski, P. [Department of Radiology, University of California, San Francisco, CA (United States)]|[Department of Radiology, Ludwig-Maximilians-University, Munich (Germany); Steinbach, L.S. [Department of Radiology, University of California, San Francisco, CA (United States); Tirman, P.F.J. [Department of Radiology, University of California, San Francisco, CA (United States)]|[San Francisco Magnetic Resonance Center, San Francisco, CA (United States); Peterfy, C.G. [Department of Radiology, University of California, San Francisco, CA (United States); Genant, H.K. [Department of Radiology, University of California, San Francisco, CA (United States)

    1996-11-01

    Objective. To present the magnetic resonance (MR) imaging findings in patients with labral cysts adjacent to the acetabulum and to examine their association with hip pathology. Design. MR images and conventional radiographs of seven patients with paralabral cysts were retrospectively reviewed by three musculoskeletal radiologists. Patients. The patients included three men and four women with hip pain, ranging in age from 29 to 82 years. Two patients had developmental dysplasia of the hip and six had a history of remote trauma/dislocation. Clinical history and follow-up were obtained in all patients. Surgery was performed on one patient. Results and conclusions. Paralabral cysts were located in the posterosuperior aspect of the hip joint in five patients and in the anterior aspect in two patients. A tear of the adjacent acetabular labrum was confirmed surgically in one patient, and in all patients the MR features suggested the presence of an abnormal labrum. Osteoarthritis was observed in three patients and there was associated subchondral cyst formation in the acetabulum adjacent to the cyst in three patients. The paralabral cyst of the hip is well visualized on MR imaging and is seen in patients with a predisposition to labral pathology. (orig.). With 3 figs., 1 tab.

  9. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    Science.gov (United States)

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  10. MR-arthrography of the acetabular labrum - radiologic-pathologic correlation in 20 cadaveric hip joints; MR-Arthrographie des Labrum acetabulare - Radiologisch-anatomische Korrelation an 20 Leichenhueften

    Energy Technology Data Exchange (ETDEWEB)

    Brossmann, J.; Steffens, J.C.; Heller, M. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie; Ploetz, G.M.J.; Hassenpflug, J. [Kiel Univ. (Germany). Klinik fuer Orthopadie

    1999-08-01

    Purpose: To investigate frequency of acetabular labral lesions in elderly hip joints, and to determine sensitivity and specificity of MR arthrography (MRa) for the detection of these abnormalities. Materials and Methods: Twenty cadaveric hip joints were examined by MRa. For MRa, 15 ml of a solution of iodinated contrast solution (Solutrast 300) and Gd-DTPA (100:1) were injected under fluoroscopic guidance. MR imaging was performed on a 1.5 TM scanner (Vision, Siemens; FOV 16 cm, matrix 256x256, fat-suppressed 3D-FLASH). Multiplanar image reconstructions were done perpendicular to the acetabulum in the oblique-coronal, oblique-axial, and radial planes. The labral specimens were examined macroscopically. Results: In 12/20 hips (60%), a labral lesion was found on pathologic examination. In 7 specimens, the labrum was partially or completely detached in the weight-bearing superior region. One flap-like variant of the labrum was seen; in 4 hip joints, the labrum was degenerated (one cystic degeneration). Pathologic findings were confirmed by MRa in 8/12 specimens (sensitivity 67%). All degenerated labra were correctly diagnosed on MRa. Three small labral detachments and the flap-like variant were misinterpreted as being normal. There were no false positive findings (specificity 100%). The accuracy was 80%. Labral lesions were seen in 6/8 and in 6/12 of hips with and without osteoarthritis, respectively. Conclusion: MRa is well suited to delineate the acetabular labrum and to diagnose labral abnormalities. Detection of small labral detachments and anatomic variants is difficult and requires some experience. Labral lesions are correlated to osteoarthritis of the hip, but may be frequently seen in the elderly without underlying osteoarthritis. (orig.) [German] Ziel: Feststellung der Haeufigkeit von Laesionen des Labrum acetabulare bei aelteren Hueftgelenkspraeparaten und Untersuchung der Sensitivitaet und Spezifitaet der MR-Arthrographie (MRa) fuer die Darstellung dieser

  11. Labral and cartilage abnormalities in young patients with hip pain: accuracy of 3-Tesla indirect MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Petchprapa, Catherine N.; Rybak, Leon D. [NYU Langone Medical Center-Hospital for Joint Diseases, Department of Radiology, New York, NY (United States); Dunham, Kevin S.; Recht, Michael P. [NYU Langone Medical Center, Department of Radiology, New York, NY (United States); Lattanzi, Riccardo [NYU Langone Medical Center, The Bernard and Irene Schwartz Center for Biomedical Imaging, New York, NY (United States)

    2015-01-15

    Assess the diagnostic accuracy of 3-T indirect magnetic resonance arthrography (iMRA) for hip cartilage and labral pathology detection using arthroscopy as the reference standard and compare it to the published performance of direct magnetic resonance arthrography (dMRA). Between 2009 and 2011, 290 patients suspected of having femoroacetabular impingement underwent iMRA. Our study group consisted of 41 of these patients (17 males, mean age 35 years; 24 females, mean age 33 years) who did not have a prior history of hip surgery and who subsequently underwent arthroscopy. Two experienced musculoskeletal radiologists separately evaluated the randomized and anonymized studies for the presence and quadrant location of labral and cartilage pathology. These recorded data were compared to arthroscopic reports. Forty-one patients had labral pathology, 34 patients had acetabular and 5 patients had femoral cartilage pathology at arthroscopy. Sensitivity, specificity, accuracy, negative- and positive-predictive values for labral lesion detection were respectively 98, 99, 99, 99 and 98 %; for acetabular cartilage lesion detection they were 69, 98, 89, 87 and 95 %; for femoral cartilage lesion detection they were 69, 95, 93 and 39 %. Sensitivities of iMRA by quadrant (anteroinferior, anterosuperior, posteroinferior, posterosuperior) for the labrum were 100.0, 95.0, NA and 85.7 %, for acetabular cartilage were NA, 58.8, NA and 39.5 % and for femoral cartilage were 50.0, 33.3, 75.0 and 75.0 %. NA indicates results not available because of the absence of findings in those quadrants. Specificities of iMRA by quadrant (anteroinferior, anterosuperior, posteroinferior, posterosuperior) for the labrum (95.0, 100.0, 95.1, 67.5 %), acetabular (100.0, 85.7, 92.6, 79.5 %) and femoral cartilage (100.0, 94.7, 96.2, 85.9 %). iMRA at 3 T is accurate in detecting labral pathology suggesting that it is a viable alternative to dMRA. (orig.)

  12. Hip Arthroscopy for Femoral-Acetabular Impingement: Do Active Claims Affect Outcomes?

    Science.gov (United States)

    Gigi, Roy; Rath, Ehud; Sharfman, Zachary T; Shimonovich, Shachar; Ronen, Itai; Amar, Eyal

    2016-04-01

    To compare outcomes of 3 patient groups undergoing hip arthroscopy. This study included 138 consecutive hip arthroscopies (106 analyzed) for femoral-acetabular impingement (FAI) with or without labral tear in patients with a minimum 1-year follow-up. Inclusion criteria included patients older than 18 with clinical or radiologic manifestation of FAI with or without labral tear. Exclusion criteria included previous hip surgery and various hip pathologies. Patients were classified into 3 study groups. Group 1 included work-related injuries with active claims ACs (n = 33); mean age, 32 (range, 19 to 63); group 2 included sports injuries with no ACs (n = 35); mean age, 32 (range, 18 to 69); and group 3 included non-sports-related injuries without pending ACs (NAS; n = 38); mean age, 45 (range, 20 to 68). Outcomes were assessed using modified Harris hip scores (mHHS) and hip outcome scores (HOS) preoperatively and during the final evaluation. Baseline score for all groups did not significantly differ (P = .210 for mHHS, P = .176 for HOS). All groups significantly improved from preoperative to final evaluation (group 1: mHHS P = .42, HOS P = .001; group 2: mHHS P arthroscopy. Hip arthroscopy as an intervention in patients with ACs provided positive outcomes, corroborating that an AC is not a contraindication for this procedure. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Atraumatic tears of the ligamentum teres are more frequent in professional ballet dancers than a sporting population.

    Science.gov (United States)

    Mayes, Susan; Ferris, April-Rose; Smith, Peter; Garnham, Andrew; Cook, Jill

    2016-07-01

    To compare the frequency of atraumatic ligamentum teres (LT) tear in professional ballet dancers with that of athletes, and to determine the relationship with clinical and imaging findings. Forty-nine male and female professional ballet dancers (98 hips) and 49 age and sex-matched non-dancing athletes (98 hips) completed questionnaires on hip symptoms and physical activity levels, underwent hip rotation range of movement (ROM) and hypermobility testing, and 3.0-Tesla magnetic resonance imaging (3 T MRI) on both hips to detect LT tears, acetabular labral tears, and articular cartilage defects, and to measure the lateral centre edge angles (LCE). A higher frequency of LT tear was found in dancers (55 %) compared with athletes (22 %, P = 0.001). The frequency and severity of LT tears in dancers increased with older age (P = 0.004, P = 0.006, respectively). The Hip and Groin Outcome Score (HAGOS) pain scores or hip rotation ROM did not differ significantly among participants with normal, partial, or complete tears of LT (P > 0.01 for all). Neither the frequency of generalised joint hypermobility (P = 0.09) nor the LCE angles (P = 0.32, P = 0.16, left and right hips respectively) differed between those with and those without LT tear. In most hips, LT tear co-existed with either a labral tear or a cartilage defect, or both. The higher frequency of atraumatic LT tears in professional ballet dancers suggests that the LT might be abnormally loaded in ballet, and caution is required when evaluating MRI, as LT tears may be asymptomatic. A longitudinal study of this cohort is required to determine if LT tear predisposes the hip joint to osteoarthritis.

  14. Hip arthroscopy in patients with recurrent pain following Bernese periacetabular osteotomy for acetabular dysplasia: operative findings and clinical outcomes

    Science.gov (United States)

    Cvetanovich, Gregory L.; Heyworth, Benton E.; Murray, Kerri; Yen, Yi-Meng; Kocher, Mininder S.; Millis, Michael B.

    2015-01-01

    To report the operative findings and outcomes of hip arthroscopy for recurrent pain following periacetabular osteotomy (PAO) for acetabular dysplasia. A departmental database was used to identify patients who underwent hip arthroscopy following PAO between 2000 and 2009. Demographic data, arthroscopic findings, functional outcome scores and patient satisfaction were analysed. Of 556 PAO patients, 17 hips in 16 patients (3.1%) underwent post-PAO hip arthroscopy. Mean age at PAO was 23.8 years, and mean age at arthroscopy was 27.0 years. Common hip arthroscopy findings included labral tears (13 hips, 81.3%), significant (≥grade 2) chondral changes (12 hips, 75%), cam impingement (7 hips, 43.8%) and pincer impingement (6 hips, 37.5%). At mean follow-up 2.8 years after arthroscopy, additional procedures had been performed in six hips (37.5%), including total hip arthroplasty in one hip. Post-PAO arthroscopy questionnaire revealed 85.7% of patients with improved hip pain, 57.1% improved hip stiffness and 57.1% improved hip function. There was no significant difference in functional outcome measures. Common post-PAO hip arthroscopy findings include labral tears, chondral changes and femoroacetabular impingement. Many patients reported subjective hip improvement from post-PAO arthroscopy, but hip outcome scores were unchanged and one-third of patients had further surgery. PMID:27011852

  15. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Fallahi, Farshid [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom); North Cumbria University Hospitals, Department of Radiology, Carlisle (United Kingdom); Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon [North Cumbria University Hospitals NHS Trust, Carlisle (United Kingdom)

    2013-09-15

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  16. Indirect magnetic resonance arthrography of the shoulder; a reliable diagnostic tool for investigation of suspected labral pathology

    International Nuclear Information System (INIS)

    Fallahi, Farshid; Green, Nick; Gadde, Sarat; Jeavons, Lisa; Armstrong, Patrick; Jonker, Leon

    2013-01-01

    Indirect magnetic resonance arthrography (I-MRA) confers significant logistical advantages over direct MRA and does not require articular injection. In this study, we determined the diagnostic performance of I-MRA in relation to conventional MRI and arthroscopy or surgery in detecting tears of the glenoid labrum, including Bankart lesions and superior labral antero-posterior (SLAP) tears in a standard clinical setting. Ninety-one symptomatic patients underwent conventional MRI and I-MRA of the affected shoulder, followed by either arthroscopy or open surgery. The scans were interpreted independently by two experienced radiology consultants with a special interest in musculoskeletal radiology. Using the surgical findings as the standard of reference, sensitivity, specificity, and diagnostic accuracy of conventional non-contrast MRI and I-MRA in the detection of labral tears were calculated. The sensitivity of I-MRA was 95 and 97 %, respectively, for two radiologists as opposed to 79 and 83 % for conventional MRI. For both radiologists, the specificity of I-MRA, as well as MRI, was 91 % for detection of labral tears of all types. Accuracy of diagnosis was 93 and 95 %, respectively, for two radiologists with indirect MRA, compared to 84 and 86 % with non-contrast MRI. This retrospective study shows that I-MRA is a highly accurate and sensitive method for the detection of labral tears. The data obtained supports the use of I-MRA as standard practice in patients with shoulder instability due to suspected labral pathology where further investigative imaging is indicated. (orig.)

  17. Comparison of shoulder positions at MR arthrography: change of labroligamentous complex shape and diagnosis of labral tears

    International Nuclear Information System (INIS)

    Kwak, Jin Young; Ha, Doo Hoe; Kim, Jeung Sook; Lee, Young Soo

    2001-01-01

    To compare the neutral, internal, and external rotation positions of the glenohumeral joint during magnetic resonance (MR) arthrography performed to assess changes in the shape of the labroligamentous complex (LLC) and in the labral tear. MR arthrography of the shoulder was retrospectively evaluated in 36 patients aged 14-66 (mean, 40) years. Fourteen cases were confirmed by arthroscopic surgery (7 SLAP lesions, 2 Bankart lesions, 1 both SLAP and Bankart lesions). Axial fat-suppressed T1-weighted spin-echo images were acquired with each shoulder in the neutral position, and with internal and external rotations. In each position, we measured the angle of rotation between the perpendicular line on the glenoid fossa and the long axis of the humeral head, analyzing the relationship between the rotational angle and changes in the shape of the LLC at each internal and external rotation, relative to the neutral position. In addition, labral tears in 14 arthroscopically confirmed joints were evaluated in each position. Mean angles of rotation relative to the neutral position were 44.1 and 45.3 degrees in internal and external rotation, respectively. Changes in the anterior LLC occurred in 25 and 24 cases of internal and external rotation, respectively. There was a significantly meaningful relationship between rotational angle and changes in the shape of the anterior LLC during external rotation, and when this changes was noticed, the rotational angle was wider (p<0.05). The posterior LLC changed in shape in 13 and 16 cases of internal and external rotation, respectively, but changes according to the angle of rotation were not statistically significant. In arthroscopically confirmed joints, diagnosis of the eight SLAP lesions at external rotation tended to become more accurate, but no statistically significant differences were noted (p=0.07). Two Bankart lesions were interpreted as a tear in all three positions, and one other such lesion was interpreted as a tear in the

  18. SLAP tears of the glenoid labrum in contact athletes.

    Science.gov (United States)

    Funk, Lennard; Snow, Martyn

    2007-01-01

    To describe the distribution and clinical presentation of labral injuries in rugby players and the time taken for them to return to sports. Retrospective cohort study. Busy shoulder practice in the North West of England, treating a large number of professional athletes. A review of 51 shoulder arthroscopies performed on professional rugby players over a 35 month period. All patients diagnosed with a SLAP lesion at arthroscopy were identified. Eighteen patients had a documented SLAP tear; this group represented our study population. Arthroscopic debridement and/or stabilization was carried out for all labral injuries using Panaloc anchors and No. 2 PDS via a 2 portal technique. Classification of injury, Satisfaction, Time to return to play. The incidence of SLAP tears in our study population was 35%. There were 11 isolated SLAP tears (61%), 3 SLAP tears associated with a Bankart lesion (17%), 2 SLAP tears associated with a posterior labral lesion (11%), and 2 SLAP tears associated with an anterior and posterior labral injuries (11%). Of the 18 SLAP tears, 14 (78%) were type 2, 3 (17%) were type 3, and 1 (5%) was type 4. None of the patients with a SLAP tear presented with symptoms of instability. MR Arthrogram had a 76% sensitivity for detecting SLAP tears. By 6 months postsurgery, 89% of patients were satisfied. Patients with isolated SLAP tears were the quickest to return to sports, at an average of 2.6 months postsurgery. SLAP tears are a common injury in rugby players. These can often be diagnosed with MR arthrography. Arthroscopic repair is associated with excellent results and early return to sports.

  19. Endoscopic Gluteus Medius Repair With Concomitant Arthroscopy for Labral Tears: A Case Series With Minimum 5-Year Outcomes.

    Science.gov (United States)

    Perets, Itay; Mansor, Yosif; Yuen, Leslie C; Chen, Austin W; Chaharbakhshi, Edwin O; Domb, Benjamin G

    2017-12-01

    To report the minimum 5-year outcomes of endoscopic gluteus medius repair for partial- and full-thickness tears with concomitant hip arthroscopy. Data for all patients who underwent hip arthroscopy between February 2009 and September 2011 were prospectively collected. We included patients who underwent endoscopic gluteus medius repair with concomitant arthroscopic labral treatment and for whom the following measures were obtained preoperatively and at a minimum of 5 years' follow-up: modified Harris Hip Score, Non-Arthritic Hip Score, Hip Outcome Score-Sports Specific Subscale, and visual analog scale score for pain. For included patients, the International Hip Outcome Tool-12 (iHOT-12) score and satisfaction rating were also available at latest follow-up. Patients with at least 1 of the following criteria were excluded: preoperative Tönnis osteoarthritis grade of 2 or greater, previous hip conditions, severe dysplasia, and Workers' Compensation claims. There were 16 patients eligible for inclusion, 14 (87.5%) of whom had minimum 5-year follow-up, with a mean of 68.8 months (range, 60.1-79.6 months). The study group consisted of 13 women (92.9%) and 1 man (7.1%) with a mean age at surgery of 57.4 years (range, 46.3-74.8 years). Outcome scores improved as follows: modified Harris Hip Score, from 52.4 to 81.2 (P = .004); Non-Arthritic Hip Score, from 48.0 to 82.5 (P = .002); Hip Outcome Score-Sports Specific Subscale, from 30.1 to 66.4 (P arthroscopy for labral tears is safe and shows favorable outcomes at minimum 5-year follow-up. Patient outcomes were as favorable at 5 years as they were at 2 years postoperatively. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Magnetic resonance appearance of posterosuperior labral peel back during humeral abduction and external rotation.

    Science.gov (United States)

    Borrero, Camilo G; Casagranda, Bethany U; Towers, Jeffrey D; Bradley, James P

    2010-01-01

    To describe the magnetic resonance appearance of posterosuperior labral peel back and determine the reliability of MR in the abducted and externally rotated (ABER) position for the prospective diagnosis of arthroscopically proven cases of posterosuperior labral peel back. After approval by the institutional review board (IRB) of the University of Pittsburgh Medical Center, USA, databases of patients who underwent arthroscopy over a 2-year period for one of three clinical diagnoses [suspected type 2 superior labrum anterior to posterior (SLAP) tears, posterior instability, or multidirectional instability] were reviewed after anonymization by an honest broker. Sixty-three cases were selected by the following inclusion criteria: operative report documenting labral peel back in the ABER position, age position (n=34). Inclusion criteria for the control group differed from those for the case group insofar as the operative note documented the absence of posterosuperior labral peel back (n=29). Cases and controls were randomized in one list and evaluated independently by two fellowship-trained musculoskeletal radiologists unaware of the surgical results and using a three-point grading system (0 = posterosuperior labrum normally positioned lateral/craniad to glenoid articular plane in ABER; 1 = posterosuperior labral tissue flush with the glenoid articular plane in ABER; 2 = posterosuperior labral tissue identified medial/caudal to glenoid articular plane in ABER). Only one image in ABER showing abnormal posterosuperior labral position was required for a grade of 1 or 2 to be assigned. Sensitivity, specificity, and positive and negative predictive value were calculated as well as the level of agreement between readers (kappa). Both readers assigned a grade of 2 to 25 of 34 patients with surgically proven labral peel back. Of the patients with surgically proven SLAP tears with peel back in ABER, reader A assigned a grade of 1 to seven patients and a grade of 0 to two

  1. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    International Nuclear Information System (INIS)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin; Kogler, Michael; Schmaranzer, Ehrenfried; Forstner, Thomas; Reichkendler, Markus

    2015-01-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  2. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    Energy Technology Data Exchange (ETDEWEB)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin [Medical University Innsbruck, Department of Radiology, Innsbruck (Austria); Kogler, Michael; Schmaranzer, Ehrenfried [District Hospital St. Johann in Tyrol, Department of Radiology, St. Johann in Tyrol (Austria); Forstner, Thomas [Johannes Keppler University, Department for Applied Systems Research and Statistics, Linz (Austria); Reichkendler, Markus [District Hospital St. Johann in Tyrol, Department of Orthopedic Surgery, St. Johann in Tyrol (Austria)

    2015-06-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  3. Magnetic resonance appearance of posterosuperior labral peel back during humeral abduction and external rotation

    Energy Technology Data Exchange (ETDEWEB)

    Borrero, Camilo G.; Casagranda, Bethany U.; Towers, Jeffrey D. [Department of Radiology, Pittsburgh, PA (United States); Bradley, James P. [Department of Orthopedics, Pittsburgh, PA (United States)

    2010-01-15

    To describe the magnetic resonance appearance of posterosuperior labral peel back and determine the reliability of MR in the abducted and externally rotated (ABER) position for the prospective diagnosis of arthroscopically proven cases of posterosuperior labral peel back. After approval by the institutional review board (IRB) of the University of Pittsburgh Medical Center, USA, databases of patients who underwent arthroscopy over a 2-year period for one of three clinical diagnoses [suspected type 2 superior labrum anterior to posterior (SLAP) tears, posterior instability, or multidirectional instability] were reviewed after anonymization by an honest broker. Sixty-three cases were selected by the following inclusion criteria: operative report documenting labral peel back in the ABER position, age <40 years, and preceding MR arthrogram evaluations with images in the ABER position (n = 34). Inclusion criteria for the control group differed from those for the case group insofar as the operative note documented the absence of posterosuperior labral peel back (n = 29). Cases and controls were randomized in one list and evaluated independently by two fellowship-trained musculoskeletal radiologists unaware of the surgical results and using a three-point grading system (0 = posterosuperior labrum normally positioned lateral/craniad to glenoid articular plane in ABER; 1 = posterosuperior labral tissue flush with the glenoid articular plane in ABER; 2 = posterosuperior labral tissue identified medial/caudal to glenoid articular plane in ABER). Only one image in ABER showing abnormal posterosuperior labral position was required for a grade of 1 or 2 to be assigned. Sensitivity, specificity, and positive and negative predictive value were calculated as well as the level of agreement between readers (kappa). Both readers assigned a grade of 2 to 25 of 34 patients with surgically proven labral peel back. Of the patients with surgically proven SLAP tears with peel back in ABER

  4. Magnetic resonance appearance of posterosuperior labral peel back during humeral abduction and external rotation

    International Nuclear Information System (INIS)

    Borrero, Camilo G.; Casagranda, Bethany U.; Towers, Jeffrey D.; Bradley, James P.

    2010-01-01

    To describe the magnetic resonance appearance of posterosuperior labral peel back and determine the reliability of MR in the abducted and externally rotated (ABER) position for the prospective diagnosis of arthroscopically proven cases of posterosuperior labral peel back. After approval by the institutional review board (IRB) of the University of Pittsburgh Medical Center, USA, databases of patients who underwent arthroscopy over a 2-year period for one of three clinical diagnoses [suspected type 2 superior labrum anterior to posterior (SLAP) tears, posterior instability, or multidirectional instability] were reviewed after anonymization by an honest broker. Sixty-three cases were selected by the following inclusion criteria: operative report documenting labral peel back in the ABER position, age <40 years, and preceding MR arthrogram evaluations with images in the ABER position (n = 34). Inclusion criteria for the control group differed from those for the case group insofar as the operative note documented the absence of posterosuperior labral peel back (n = 29). Cases and controls were randomized in one list and evaluated independently by two fellowship-trained musculoskeletal radiologists unaware of the surgical results and using a three-point grading system (0 = posterosuperior labrum normally positioned lateral/craniad to glenoid articular plane in ABER; 1 = posterosuperior labral tissue flush with the glenoid articular plane in ABER; 2 = posterosuperior labral tissue identified medial/caudal to glenoid articular plane in ABER). Only one image in ABER showing abnormal posterosuperior labral position was required for a grade of 1 or 2 to be assigned. Sensitivity, specificity, and positive and negative predictive value were calculated as well as the level of agreement between readers (kappa). Both readers assigned a grade of 2 to 25 of 34 patients with surgically proven labral peel back. Of the patients with surgically proven SLAP tears with peel back in ABER

  5. Magnetic resonance imaging evaluation of capsulolabral tears after traumatic primary anterior shoulder dislocation. A prospective comparison with arthroscopy of 25 cases

    DEFF Research Database (Denmark)

    Suder, P.A.; Frich, Lars Henrik; Hougaard, K.

    1995-01-01

    . Subacute MRI evaluation identified 15 labral tears, 12 Hill-Sachs lesions, 1 total rotator cuff lesion, 1 partial joint side rotator cuff lesion, and 1 partial rupture of the biceps tendon. Arthroscopic examination revealed 22 labral tears, 15 Hill-Sachs lesions, 1 total rotator cuff lesion, 1 partial...... joint side rotator cuff tear, 1 partial rupture of the biceps tendon, and 1 osseous Bankart lesion. Anterior capsulolabral tears and Hill-Sachs lesions appeared with a high incidence after acute anterior primary shoulder dislocation. Conventional MRI was only moderately reliable in the preoperative...... evaluation of labral tears and Hill-Sachs lesions, and it failed to give an accurate, differentiated preoperative diagnosis of the capsulolabral lesions....

  6. The use of ultrasound in the assessment of the glenoid labrum of the glenohumeral joint. Part II: Examples of labral pathologies

    Directory of Open Access Journals (Sweden)

    Wojciech Krzyżanowski

    2012-09-01

    Full Text Available Labral pathologies of the glenohumeral joint are most commonly caused by trauma. The majority of lesions affect the anterior part of labrum, resulting from much higher frequency of anterior shoulder dislocations over posterior ones. Another subgroup of labral lesions, not directly related to joint instability, are SLAP tears. Other findings include degenerative changes of labrum and paralabral cysts. Diagnostic imaging is crucial for making a decision regarding operative treatment. Apart from a standard X-ray examination, the imaging mainly relies on magnetic resonance or computed tomography arthrography. Based on their own experience, the authors propose the use of ultrasound in the assessment of labral tears of the glenohumeral joint. Different signs indicating labral pathology may be discovered and assessed during ultrasound examination. They include permanent displacement of the labrum onto the glenoid, labral instability during dynamic examination, lack of the labrum in the anatomical position, hypoechoic zone at the base of the labrum >2 mm in width, residual or swollen labrum as well as paralabral cyst(s. The most frequent appearance of labral pathology is displacement of the anteroinferior labrum onto the external aspect of the glenoid typically seen after anterior shoulder dislocation. The another most important US feature is labral instability while dynamically examined. The swelling or reduced size of the labrum usually indicates degeneration. This article presents sonographic images of selected labral pathologies.

  7. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    Energy Technology Data Exchange (ETDEWEB)

    Chun, K.A. [The Catholic University of Korea Uijongbu St. Mary' s Hospital, Department of Radiology, Uijongbu, Kyunggi-Do 480-130 (Korea); University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States); Morcuende, J. [University of Iowa Hospitals and Clinics, Department of Orthopaedic Surgery, Iowa City (United States); El-Khoury, G.Y. [University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States)

    2004-12-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  8. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    International Nuclear Information System (INIS)

    Chun, K.A.; Morcuende, J.; El-Khoury, G.Y.

    2004-01-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  9. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    International Nuclear Information System (INIS)

    Zbojniewicz, Andrew M.; Emery, Kathleen H.; Maeder, Matthew E.; Salisbury, Shelia R.

    2014-01-01

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  10. Rotator cuff tears in children and adolescents: experience at a large pediatric hospital

    Energy Technology Data Exchange (ETDEWEB)

    Zbojniewicz, Andrew M.; Emery, Kathleen H. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Maeder, Matthew E. [University of Cincinnati College of Medicine, Department of Radiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States); Lenox Hill Hospital, Department of Radiology, New York, NY (United States); Salisbury, Shelia R. [University of Cincinnati College of Medicine, Division of Biostatistics and Epidemiology, Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2014-06-15

    Prior literature, limited to small case series and case reports, suggests that rotator cuff tears are rare in adolescents. However, we have identified rotator cuff tears in numerous children and adolescents who have undergone shoulder MRI evaluation. The purpose of this study is to describe the prevalence and characteristics of rotator cuff tears in children and adolescents referred for MRI evaluation of the shoulder at a large pediatric hospital and to correlate the presence of rotator cuff tears with concurrent labral pathology, skeletal maturity and patient activity and outcomes. We reviewed reports from 455 consecutive non-contrast MRI and magnetic resonance arthrogram examinations of the shoulder performed during a 2-year period, and following exclusions we yielded 205 examinations in 201 patients (ages 8-18 years; 75 girls, 126 boys). Rotator cuff tears were classified by tendon involved, tear thickness (partial or full), surface and location of tear (when partial) and presence of delamination. We recorded concurrent labral pathology when present. Physeal patency of the proximal humerus was considered open, closing or closed. Statistical analysis was performed to evaluate for a relationship between rotator cuff tears and degree of physeal patency. We obtained patient activity at the time of injury, surgical reports and outcomes from clinical records when available. Twenty-five (12.2%) rotator cuff tears were identified in 17 boys and 7 girls (ages 10-18 years; one patient had bilateral tears). The supraspinatus tendon was most frequently involved (56%). There were 2 full-thickness and 23 partial-thickness tears with articular-side partial-thickness tears most frequent (78%). Insertional partial-thickness tears were more common (78%) than critical zone tears (22%) and 10 (43%) partial-thickness tears were delamination tears. Nine (36%) patients with rotator cuff tears had concurrent labral pathology. There was no statistically significant relationship between

  11. Conservative management of an elite ice hockey goaltender with femoroacetabular impingement (FAI): a case report

    Science.gov (United States)

    MacIntyre, Kyle; Gomes, Brendan; MacKenzie, Steven; D’Angelo, Kevin

    2015-01-01

    Objective: To detail the presentation of an elite male ice hockey goaltender with cam-type femoroacetabular impingement (FAI) and acetabular labral tears. This case will outline the prevalence, clinical presentation, imaging criteria, pathomechanics, and management of FAI, with specific emphasis on the ice hockey goaltender. Clinical Features: A 22-year old retired ice hockey goaltender presented to a chiropractor after being diagnosed by an orthopaedic surgeon with MRI confirmed left longitudinal and chondral flap acetabular labral tears and cam-type femoroacetabular impingement (FAI). As the patient was not a candidate for surgical intervention, a multimodal conservative treatment approach including manual therapy, electroacupuncture and rehabilitation exercises were implemented. Summary: FAI is prevalent in ice hockey players, particularly with goaltenders. Both skating and position-dependent hip joint mechanics involved in ice hockey may exacerbate or contribute to acquired and congenital forms of symptomatic FAI. As such, practitioners managing this population must address sport-specific demands in manual therapy, rehabilitation and physical training, to improve functional outcomes and prevent future injury. PMID:26816416

  12. Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement

    Energy Technology Data Exchange (ETDEWEB)

    Linda, Dorota D. [University of Toronto, Department of Medical Imaging, Joint Department of Medical Imaging, Division of Musculoskeletal Imaging, Toronto (Canada); Mount Sinai Hospital, Toronto, ON (Canada); Naraghi, Ali; White, Lawrence M. [University of Toronto, Department of Medical Imaging, Joint Department of Medical Imaging, Division of Musculoskeletal Imaging, Toronto (Canada); Murnaghan, Lucas; Whelan, Daniel [University of Toronto, Department of Surgery, Division of Orthopedics, Toronto (Canada)

    2017-03-15

    To investigate the accuracy of non-arthrographic 3-T MRI compared to hip arthroscopy in the assessment of labral and cartilaginous pathology in patients with suspected FAI. Following IRB approval and waived consent, 42 consecutive cases of suspected FAI with non-arthrographic 3-T MRI and arthroscopy of the hip were reviewed. High-resolution TSE MR imaging was evaluated in consensus by two musculoskeletal radiologists, blinded to arthroscopic findings, for the presence of labral tears and articular cartilage lesions. Acetabular cartilage was categorized as normal, degeneration/fissuring, delamination, or denudation. MRI findings were compared to arthroscopy. Sensitivity, specificity, accuracy, and predictive values for MRI were calculated using arthroscopy as the standard of reference. Forty-two hips in 38 patients with a mean age of 29 (range 13-45 years) were assessed. Mean interval between MRI and arthroscopy was 154 days (range 27-472 days). MRI depicted 41 cases with labral tears (sensitivity 100%, specificity 50%, accuracy 98%, PPV 98%, NPV 100%), 11 cases with femoral cartilage abnormalities (sensitivity 85%, specificity 100%, accuracy 95%, PPV 100%, NPV 94%), and 36 cases with acetabular cartilage lesions (sensitivity 94% specificity 67%, accuracy 90%, PPV 94%, NPV 67%). Of the 36 cases with acetabular cartilage lesions on MRI, 7 were characterized as degeneration/fissuring, 26 as delamination, and 3 as denudation, with discordant results between MRI and arthroscopy for grading of articular cartilage in ten cases. Non-arthrographic 3-T MR imaging is a highly accurate technique for evaluation of the labrum and cartilage in patients with clinically suspected FAI. (orig.)

  13. Accuracy of non-arthrographic 3T MR imaging in evaluation of intra-articular pathology of the hip in femoroacetabular impingement

    International Nuclear Information System (INIS)

    Linda, Dorota D.; Naraghi, Ali; White, Lawrence M.; Murnaghan, Lucas; Whelan, Daniel

    2017-01-01

    To investigate the accuracy of non-arthrographic 3-T MRI compared to hip arthroscopy in the assessment of labral and cartilaginous pathology in patients with suspected FAI. Following IRB approval and waived consent, 42 consecutive cases of suspected FAI with non-arthrographic 3-T MRI and arthroscopy of the hip were reviewed. High-resolution TSE MR imaging was evaluated in consensus by two musculoskeletal radiologists, blinded to arthroscopic findings, for the presence of labral tears and articular cartilage lesions. Acetabular cartilage was categorized as normal, degeneration/fissuring, delamination, or denudation. MRI findings were compared to arthroscopy. Sensitivity, specificity, accuracy, and predictive values for MRI were calculated using arthroscopy as the standard of reference. Forty-two hips in 38 patients with a mean age of 29 (range 13-45 years) were assessed. Mean interval between MRI and arthroscopy was 154 days (range 27-472 days). MRI depicted 41 cases with labral tears (sensitivity 100%, specificity 50%, accuracy 98%, PPV 98%, NPV 100%), 11 cases with femoral cartilage abnormalities (sensitivity 85%, specificity 100%, accuracy 95%, PPV 100%, NPV 94%), and 36 cases with acetabular cartilage lesions (sensitivity 94% specificity 67%, accuracy 90%, PPV 94%, NPV 67%). Of the 36 cases with acetabular cartilage lesions on MRI, 7 were characterized as degeneration/fissuring, 26 as delamination, and 3 as denudation, with discordant results between MRI and arthroscopy for grading of articular cartilage in ten cases. Non-arthrographic 3-T MR imaging is a highly accurate technique for evaluation of the labrum and cartilage in patients with clinically suspected FAI. (orig.)

  14. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  15. Prevalence of the acetabular sublabral sulcus at MR arthrography in patients under 17 years of age: does it exist?

    Energy Technology Data Exchange (ETDEWEB)

    Magerkurth, Olaf [University of Michigan, Department of Radiology, Ann Arbor, MI (United States); Hospital Baden, Department of Radiology, Baden (Switzerland); Jacobson, Jon A.; Morag, Yoav; Fessell, David [University of Michigan, Department of Radiology, Ann Arbor, MI (United States); Bedi, Asheesh; Sekiya, Jon K. [University of Michigan, Department of Orthopedic Surgery, Ann Arbor, MI (United States)

    2015-04-18

    To retrospectively determine characteristics of contrast-filled acetabular labral clefts in patients under the age of 17 years at MR arthrography (Mra) correlated with arthroscopy, which may impact the thinking regarding the existence of a sublabral sulcus. After IRB approval, 41 patients under the age of 17 who had MRa were identified. The following observations of contrast-filled clefts were assessed: (1) presence/absence, (2) location, (3) depth, (4) abnormal signal within the labrum and (5) shape (linear, gaping, complex). Fisher's exact and the Wilcoxon matched-pairs signed-rank test were performed. Interreader agreement was calculated with Cohen's k. Reader 1 found clefts in 41 %. Depth was less than half in 6 %, more than half in 65 % and full thickness in 29 %. Shape was linear in 53 %, gaping in 18 % and complex in 29 %. Signal changes occurred in 88 %. Reader 2 found clefts in 29 %. Depth was less than half in 17 %, more than half in 58 % and full thickness in 25 %. Shape was linear in 50 %, gaping in 42 % and complex in 17 %. Signal changes occurred in 50 %. None of the clefts fulfilled the criteria for a sublabral sulcus at MRa and arthroscopy. None of the clefts found in our subjects under the age of 17 years met the MRa and arthroscopy criteria for a sublabral sulcus, which supports the theory that such clefts represent labral tears. (orig.)

  16. Risk factors for the need of hip arthroscopy following periacetabular osteotomy

    Science.gov (United States)

    Hartig-Andreasen, Charlotte; Troelsen, Anders; Thillemann, Theis M.; Gelineck, John; Søballe, Kjeld

    2015-01-01

    Despite the frequency of labral tears in symptomatic developmental dysplasia of the hip, no consensus exists regarding the treatment of coexisting dysplasia of the hip and tearing of the acetabular labrum. The purpose of this prospective, MR arthrography (MRA) based 2-year follow-up study was to identify risk factors predicting the need for a hip arthroscopy (HA) after periacetabular osteotomy (PAO). Ninety-nine patients (104 hips) scheduled for PAO were evaluated preoperatively and at 2-year follow-up. MRA was performed in all patients prior to PAO. At follow-up, patients were divided into a non-arthroscopy and arthroscopy group. The two groups were compared clinical and radiological, and risk factors for HA after PAO were calculated. Patient reported outcome measures (WOMAC, Oxford Hip and SF36) were filled out before PAO and at follow-up. Ninety-five hips (91.3%) were evaluated. Twenty-six hips (27%) required an arthroscopy within 2 years of the PAO. Risk factors were preoperative borderline dysplasia, acetabular retroversion and complete labral detachment. Labral tearing, degeneration or hypertrophy did not negatively affect the outcome of PAO. Patients not requiring an arthroscopy had a statistically significant better outcome measured by patients reported outcome measures. After PAO, 27% of the hips needed intra-articular assessment. Conventional radiographs and MRA analysis can be used to identify predictors for patients requiring HA after PAO. At 2-year follow-up, the clinical outcome improved in all patients. However, those patients who had no need of a HA after their PAO had superior results. PMID:27011862

  17. Magnetic resonance evaluation of the labral capsular ligamentous complex: a pictorial review

    International Nuclear Information System (INIS)

    Connell, D.A.; Potter, H.G.

    1999-01-01

    Magnetic resonance imaging of the shoulder is a common imaging test, and in the course of routine evaluation it can provide accurate information regarding the labral capsular ligamentous complex (LCLC). Common patterns of labral injury include fraying, flap tears and labral distraction, which can be readily identified on both coronal and axial planes by paying attention to signal and morphological characteristics. Capsular and ligamentous pathology may be subtle, but is recognizable using a high-resolution technique that has differential contrast between native intra-articular fluid and the adjacent labrum and capsular restraints. Common patterns of capsular injury include a thickened, hyperintense capsule, sometimes with disruption and retraction. The inferior glenohumeral ligament is the primary stabilizer of the shoulder joint, and although failure of this structure is uncommon, the injury is easily identified. Shoulder instability is a common presentation, the diagnosis of which is dependent upon recognising various injury patterns including Bankart lesions, reverse Bankart lesions, anterior labroligamentous periosteal sleeve avulsion (ALPSA) and failure of the inferior glenohumeral ligament. Copyright (1999) Blackwell Science Pty Ltd

  18. Femoro-acetabular impingement and hip pain with conventionally normal x-rays.

    LENUS (Irish Health Repository)

    Baker, J F

    2010-06-01

    There has in recent years been a fundamental change in the understanding of hip pain in the young adult and hip pain without plain radiographic findings of arthritis. Pain in these groups has long represented a diagnostic and therapeutic challenge. With new appreciation of hip biomechanics, pathological processes and the arrival of modern imaging modalities we now have a greater understanding of non-arthritic hip pathology. One of the commonest yet least well recognized \\'new\\' diagnoses around the hip is femoro-acetabular impingement (FAI). FAI is a developmental condition of the hip joint that is associated with abnormal anatomical configuration and thus joint mechanics on either the femoral or acetabular sides or both. It is hypothesized to have a variety of precipitants and may ultimately lead to labral and chondral injury and what has previously been referred to as \\'primary\\' or \\'idiopathic\\' hip osteoarthritis.

  19. Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Chopra, A. [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Grainger, A.J.; Robinson, Philip [Chapel Allerton Hospital, Radiology Department, Leeds Teaching Hospitals, Leeds (United Kingdom); Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Dube, B.; Evans, R.; Hodgson, R. [Chapel Allerton Hospital, University of Leeds and NHIR Leeds Musculoskeletal Biomedical Research Centre, Leeds (United Kingdom); Conroy, J. [Harrogate and District NHS Trust, Trauma and Orthopaedics Department, Harrogate (United Kingdom); Macdonald, D. [Chapel Allerton Hospital, Trauma and Orthopaedics Department, Leeds Teaching Hospitals, Leeds (United Kingdom)

    2018-03-15

    To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI. circle Conventional 3T MRI is equivalent to 1.5T MRA for diagnosing labral tears. (orig.)

  20. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  1. Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: Focus on isotropic fat-suppressed proton density and VIBE sequences

    International Nuclear Information System (INIS)

    Park, S.Y.; Lee, I.S.; Park, S.K.; Cheon, S.J.; Ahn, J.M.; Song, J.W.

    2014-01-01

    Aim: To compare the diagnostic accuracies of three-dimensional (3D) isotropic magnetic resonance arthrography (MRA) using fat-suppressed proton density (PD) or volume interpolated breath-hold examination (VIBE) sequences with that of conventional MRA for the diagnosis of rotator cuff and labral lesions. Materials and methods: Eighty-six patients who underwent arthroscopic surgery were included. 3D isotropic sequences were performed in the axial plane using fat-suppressed PD (group A) in 53 patients and using VIBE (group B) in 33 patients. Reformatted images were obtained corresponding to conventional images, and evaluated for the presence of labral and rotator cuff lesions using conventional and 3D isotropic sequences. The diagnostic performances of each sequence were determined using arthroscopic findings as the standard. Results: Good to excellent interobserver agreements were obtained for both 3D isotropic sequences for the evaluation of rotator cuff and labral lesions. Excellent agreement was found between two-dimensional (2D) and 3D isotropic MRA, except for supraspinatus tendon (SST) tears by both readers and for subscapularis tendon (SCT) tears by reader 2 in group B. 2D MRA and 3D isotropic sequences had high diagnostic performances for rotator and labral tears, and the difference between the two imaging methods was insignificant. Conclusions: The diagnostic performances of 3D isotropic VIBE and PD sequences were similar to those of 2D MRA

  2. Labral Reattachment in Femoroacetabular Impingement Surgery Results in Increased 10-year Survivorship Compared With Resection.

    Science.gov (United States)

    Anwander, Helen; Siebenrock, Klaus A; Tannast, Moritz; Steppacher, Simon D

    2017-04-01

    Since the importance of an intact labrum for normal hip function has been shown, labral reattachment has become the standard method for open or arthroscopic treatment of hips with femoroacetabular impingement (FAI). However, no long-term clinical results exist evaluating the effect of labral reattachment. A 2-year followup comparing open surgical treatment of FAI with labral resection versus reattachment was previously performed at our clinic. The goal of this study was to report a concise followup of these patients at a minimum of 10 years. We asked if patients undergoing surgical hip dislocation for the treatment of mixed-type FAI with labral reattachment compared with labral resection had (1) improved hip pain and function based on the Merle d'Aubigné-Postel score; and (2) improved survival at 10-year followup. Between June 1999 and July 2002, we performed surgical hip dislocation with femoral neck osteoplasty and acetabular rim trimming in 52 patients (60 hips) with mixed-type FAI. In the first 20 patients (25 hips) until June 2001, a torn labrum or a detached labrum in the area of acetabular rim resection was resected. In the next 32 patients (35 hips), reattachment of the labrum was performed. The same indications were used to perform both procedures during the periods in question. Of the 20 patients (25 hips) in the first group, 19 patients (95%) (24 hips [96%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 13 years; range, 12-14 years). Of the 32 patients (35 hips) in the second group, 29 patients (91%) (32 hips [91%]) were available for clinical and/or radiographic followup at a minimum of 10 years (mean, 12 years; range, 10-13 years). We used the anterior impingement test to assess pain. Function was assessed using the Merle d'Aubigné- Postel score and ROM. Survivorship calculation was performed using the method of Kaplan-Meier with failure defined as conversion to THA, progression of osteoarthritis (of one

  3. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex.

    Science.gov (United States)

    Taylor, Samuel A; Khair, M Michael; Gulotta, Lawrence V; Pearle, Andrew D; Baret, Nikolas J; Newman, Ashley M; Dy, Christopher J; O'Brien, Stephen J

    2015-02-01

    The purpose of this study was to define the limits of diagnostic glenohumeral arthroscopy and determine the prevalence and frequency of hidden extra-articular "bicipital tunnel" lesions among chronically symptomatic patients. Eight fresh-frozen cadaveric specimens underwent diagnostic glenohumeral arthroscopy with percutaneous tagging of the long head of the biceps tendon (LHBT) during maximal tendon excursion. The percentage of visualized LHBT was calculated relative to the distal margin of subscapularis tendon and the proximal margin of the pectoralis major tendon. Then, a retrospective review of 277 patients who underwent subdeltoid transfer of the LHBT to the conjoint tendon were retrospectively analyzed for lesions of the biceps-labral complex. Lesions were categorized by anatomic location (inside, junctional, or bicipital tunnel). Inside lesions were labral tears. Junctional lesions were LHBT tears visualized during glenohumeral arthroscopy. Bicipital tunnel lesions were extra-articular lesions hidden from view during standard glenohumeral arthroscopy. Seventy-eight percent of LHBT were visualized relative to the distal margin of the subscapularis tendon and only 55% relative to the proximal margin of the pectoralis major tendon. No portion of the LHBT inferior to the subscapularis tendon was visualized. Forty-seven percent of patients had hidden bicipital tunnel lesions. Scarring was most common and accounted for 48% of all such lesions. Thirty-seven percent of patients had multiple lesion locations. Forty-five percent of patients with junctional lesions also had hidden bicipital tunnel lesions. The only offending lesion was in the bicipital tunnel for 18% of patients. Diagnostic glenohumeral arthroscopy fails to fully evaluate the biceps-labral complex because it visualizes only 55% of the LHBT relative to the proximal margin of the pectoralis major tendon and did not identify extra-articular bicipital tunnel lesions present in 47% of chronically

  4. [Rotator cuff tear athropathy prevalence].

    Science.gov (United States)

    Guerra-Soriano, F; Encalada-Díaz, M I; Ruiz-Suárez, M; Valero-González, F S

    2017-01-01

    Glenohumeral arthritis secondary to massive rotator cuff tear presents with a superior displacement and femoralization of the humeral head with coracoacromial arch acetabularization. The purpose of this study was to establish prevalence of rotator cuff tear artropathy (CTA) at our institution. Four hundred electronic records were reviewed from which we identified 136 patients with rotator cuff tears. A second group was composed with patients with massive cuff tears that were analized and staged by the Seebauer cuff tear arthropathy classification. Thirty four patients with massive rotator cuff tears were identified, 8 male and 26 female (age 60.1 ± 10.26 years). Massive rotator cuff tear prevalence was 25%. CTA prevalence found in the rotator cuff group was 19 and 76% in the massive cuff tears group. Patients were staged according to the classification with 32% in stage 1a, 11% 1b, 32% 2a and 0% 2b. CTA prevalence in patients with rotator cuff tears and massive cuff tears is higher than the one reported in American population. We consider that a revision of the Seebauer classification to be appropriate to determine its reliability.

  5. Labral reconstruction: when to perform and how

    Directory of Open Access Journals (Sweden)

    Brian J White

    2015-07-01

    Full Text Available Over the past decade, the understanding of the anatomy and function of the hip joint has continuously evolved, and surgical treatment options for the hip have significantly progressed. Originally, surgical treatment of the hip primarily involved resection of damaged tissue. Procedures that maintain and preserve proper hip anatomy, such as labral repair and femoroacetabular impingement (FAI correction, have shown superior results, in terms of pain reduction, increased function, and ability to return to activities. Labral reconstruction is a treatment option that uses a graft to reconstruct the native labrum. The technique and outcomes of labral reconstruction have been described relatively recently, and labral reconstruction is a cutting edge procedure that has shown promising early outcomes. The aim of this article is to review the current literature on hip labral reconstruction. We will review the indications for labral reconstruction, surgical technique and graft options, and surgical outcomes that have been described to date. Labral reconstruction provides an alternative treatment option for challenging intra-articular hip problems. Labral reconstruction restores the original anatomy of the hip and has the potential to preserve the longevity of the hip joint. This technique is an important tool in the orthopaedic surgeon’s arsenal for hip joint treatment and preservation.

  6. Arthroscopic Hip Labral Repair: The Iberian Suture Technique

    OpenAIRE

    Stubbs, Allston J.; Andersen, Jason S.; Mannava, Sandeep; Wooster, Benjamin M.; Howse, Elizabeth A.; Winter, S. Bradley

    2014-01-01

    Arthroscopic hip labral repair has beneficial short-term outcomes; however, debate exists regarding ideal surgical labral repair technique. This technical note presents an arthroscopic repair technique that uses intrasubstance labral suture passage to restore the chondrolabral interface. This “Iberian suture technique” allows for an anatomic repair while posing minimal risk of damage to the labral and chondral tissues.

  7. Labral reconstruction with iliotibial band autografts and semitendinosus allografts improves hip joint contact area and contact pressure: an in vitro analysis.

    Science.gov (United States)

    Lee, Simon; Wuerz, Thomas H; Shewman, Elizabeth; McCormick, Frank M; Salata, Michael J; Philippon, Marc J; Nho, Shane J

    2015-01-01

    .2%, P=.0014) and contact pressure (at 20°: 97.1%±3.18%, P=.0017; at 60°: 97.4%±4.39%, P=.0027) from the resected state. Comparative analysis demonstrated no statistically significant differences between either graft reconstruction in relation to contact area, contact pressure, or peak force. Segmental anterosuperior labral resection results in significantly decreased contact areas and increased contact pressures, while labral reconstruction partially restores time-zero acetabular contact areas and pressures as compared with the resected state. Although labral reconstruction improved the measured biomechanical properties as compared with the resected state, some of these properties remained significantly different compared with the native intact labrum. Labral reconstruction appears to improve femoroacetabular joint biomechanics as compared with the labrum-resected state; these improved biomechanics may translate into increased joint function clinically. © 2014 The Author(s).

  8. Anteroinferior tears of the glenoid labrum: fat-suppressed fast spin-echo T2 versus gradient-recalled echo MR images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); De Smet, A A [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); Norris, M A [Department of Radiology, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States); Orwin, J F [Department of Orthopedic Surgery, University of Wisconsin Hospital and Clinics, 600 Highland Avenue, Madison, WI 53792 (United States)

    1997-05-01

    Objective. To compare fat-suppressed fast spin-echo (FSE) T2-weighted images with gradient-recalled echo (GRE) T2*-weighted images in the evaluation of anteroinferior labral tears. Design. MR images were retrospectively reviewed by two radiologists masked to the history and arthroscopic findings. They separately interpreted the anteroinferior labrum as torn or intact, first on one pulse sequence and then, 4 weeks later, on the other sequence. The MR interpretations were correlated with the arthroscopic findings. Patients. Nine patients with anteroinferior labral tears, and nine similarly-aged patients with normal, labra were studied. Results and conclusions. Observer 1 had a sensitivity of 0.56 on the GRE images and 0.67 on the FSE images (P>0.5), with a specificity of 1.0 for both sequences. Observer 2 had a sensitivity of 0.78 and a specificity of 0.89 for both sequences. In this small study there is no significant difference between GRE and fat-suppressed FSE images in their ability to diagnose anteroinferior labral tears. When evaluating the labrum with conventional MRI, axial fat-suppressed FSE T2-weighted images can be used in place of GRE images without a loss of accuracy. (orig.). With 3 figs., 1 tab.

  9. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  10. Risk factors for the need of hip arthroscopy following periacetabular osteotomy

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Troelsen, Anders; Thillemann, Theis M

    2015-01-01

    was to identify risk factors predicting the need for a hip arthroscopy (HA) after periacetabular osteotomy (PAO). Ninety-nine patients (104 hips) scheduled for PAO were evaluated preoperatively and at 2-year follow-up. MRA was performed in all patients prior to PAO. At follow-up, patients were divided into a non-arthroscopy...... and arthroscopy group. The two groups were compared clinical and radiological, and risk factors for HA after PAO were calculated. Patient reported outcome measures (WOMAC, Oxford Hip and SF36) were filled out before PAO and at follow-up. Ninety-five hips (91.3%) were evaluated. Twenty-six hips (27%) required...... an arthroscopy within 2 years of the PAO. Risk factors were preoperative borderline dysplasia, acetabular retroversion and complete labral detachment. Labral tearing, degeneration or hypertrophy did not negatively affect the outcome of PAO. Patients not requiring an arthroscopy had a statistically significant...

  11. Posterior labral injury in contact athletes.

    Science.gov (United States)

    Mair, S D; Zarzour, R H; Speer, K P

    1998-01-01

    Nine athletes (seven football offensive linemen, one defensive lineman, and one lacrosse player) were found at arthroscopy to have posterior labral detachment from the glenoid. In our series, this lesion is specific to contact athletes who engage their opponents with arms in front of the body. All patients had pain with bench pressing and while participating in their sport, diminishing their ability to play effectively. Conservative measures were ineffective in relieving their symptoms. Examination under anesthesia revealed symmetric glenohumeral translation bilaterally, without evidence of posterior instability. Treatment consisted of glenoid rim abradement and posterior labral repair with a bioabsorbable tack. All patients returned to complete at least one full season of contact sports and weightlifting without pain (minimum follow-up, > or = 2 years). Although many injuries leading to subluxation of the glenohumeral joint occur when an unanticipated force is applied, contact athletes ready their shoulder muscles in anticipation of impact with opponents. This leads to a compressive force at the glenohumeral joint. We hypothesize that, in combination with a posteriorly directed force at impact, the resultant vector is a shearing force to the posterior labrum and articular surface. Repeated exposure leads to posterior labral detachment without capsular injury. Posterior labral reattachment provides consistently good results, allowing the athlete to return to competition.

  12. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Llopis, Eva; Schwartz, Richard B.; Bencardino, Jenny T.

    2009-01-01

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  13. Obturator externus bursa: prevalence of communication with the hip joint and associated intra-articular findings in 200 consecutive hip MR arthrograms

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara [Corades, S.L., Majadahonda-Madrid (Spain); Massachusetts General Hospital, Division of Musculoksleletal Radiology, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Alzira (Valencia) (Spain); Schwartz, Richard B. [Longwood MRI Specialists, Brookline, MA (United States); Bencardino, Jenny T. [NYU Department of Radiology, New York, NY (United States)

    2009-11-15

    The purpose of the study was to demonstrate the prevalence of communication between the hip joint and the obturator externus bursa on hip MR arthrography. Following institutional review board approval, 200 hip MR arthrograms in 196 subjects were independently reviewed by two musculoskeletal radiologists. Discrepancies were resolved by adjudication. The presence or absence of communication between the hip joint and the obturator externus bursa was recorded. Associated lesions involving the acetabular labrum and articular cartilage were recorded. The obturator externus bursa was shown to communicate with the hip joint in 11 of the 200 (5.5%) hip MR arthrograms. Of these, six were in men and five were in women. The age range was 15-63 years with a mean age of 34 years. All 11 patients had labral tears. Eight of the 11 had cartilage lesions. The obturator externus bursa can be seen to communicate with the hip joint in 5.5% of hip MR arthrograms. Associated labral and cartilage lesions are common. (orig.)

  14. Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum

    International Nuclear Information System (INIS)

    Lee, Marc J.; Motamedi, Kambiz; Chow, Kira; Seeger, Leanne L.

    2008-01-01

    The purpose of this study was to determine the utility of fat-suppressed gradient-recalled echo (GRE) compared with conventional spin echo T1-weighted (T1W) sequences in direct shoulder MR arthrography for evaluating labral tears. Three musculoskeletal radiologists retrospectively reviewed MR arthrograms performed over a 12-month period for which surgical correlation was available. Of 180 serial arthrograms, 31 patients had surgery with a mean of 48 days following imaging. Paired coronal oblique and axial T1W or GRE sequences were analyzed by consensus for labral tear (coronal oblique two-dimensional multi-echo data image combination, 2D MEDIC; and axial three-dimensional double-echo steady-state, 3D DESS; Siemens MAGNETOM Sonata 1.5-T MR system). Interpretations were correlated with operative reports. Of 31 shoulders, 25 had labral tears at surgery. The GRE sequences depicted labral tears in 22, while T1W images depicted tears in 16 (sensitivity 88% versus 64%; p 0.7). Specificities were somewhat lower for GRE. Thin section GRE sequences are more sensitive than T1W for the detection of anterior and posterior labral tears. As the specificity of GRE was lower, it should be considered as an adjunctive imaging sequence that may improve depiction of labral tears, particularly smaller tears, in routine MR arthrography protocols. (orig.)

  15. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    International Nuclear Information System (INIS)

    Werner, Clement M.L.; Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H.; Ruckstuhl, Thomas; Bouaicha, Samy

    2011-01-01

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE ( 12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  16. Hip arthroscopy: prevalence of intra-articular pathologic findings after traumatic injury of the hip.

    Science.gov (United States)

    Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H

    2014-03-01

    The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when

  17. Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Jung, Jee Young; Yoon, Young Cheol; Yi, Sang-Kyu; Yoo, Jaechul; Choe, Bong-Keun

    2009-01-01

    To compare the diagnostic value of indirect magnetic resonance arthrography (I-MRA) with that of direct MR arthrography (D-MRA) for labral tears, rotator cuff tears, and long head of biceps tendon (LHBT) tears using a 3-T MR unit. Institutional review board approval was given; written informed consent was obtained from all patients. From November 2005 to June 2006, 19 patients (eight men and 11 women; mean age, 51 years) who had undergone both I-MRA and D-MRA underwent arthroscopic surgery. Both methods were performed in fat-saturated axial, coronal oblique, and sagittal oblique T1-weighted sequences, as well as axial and coronal oblique T2-weighted sequences. Two radiologists independently and retrospectively evaluated two sets of MRA for the diagnosis of superior and anterior labral tears, subscapularis tendon (SSC), and supraspinatus-infraspinatus tendon (SSP-ISP) tears, and LHBT tears. With the arthroscopic finding as a gold standard, we analyzed statistical differences of sensitivities and specificities between two sets of MRA and inter-observer agreement was evaluated using the kappa value. The sensitivity and specificity of I-MRA and D-MRA for reader 1 were 79/80% and 71/80%, respectively, for superior labral tears; 100/100% and 100/100%, respectively, for anterior labral tears; 64/75% and 64/100%, respectively, for SSC tears; 100/86% and 100/100%, respectively, for SSP-ISP tears; and 67/100% and 78/100%, respectively, for LHBT tears. Those of I-MRA and D-MRA for reader 2 were 86/80% and 71/100%, respectively, for superior labral tears; 100/83% and 100/100%, respectively, for anterior labral tears; 64/88% and 82/100%, respectively, for SSC tears; 92/86% and 100/100%, respectively, for SSP-ISP tears; and 78/90% and 89/100%, respectively, for LHBT tears. No significant differences were found between the methods. Inter-observer agreements were higher than moderate (κ > 0.41) with both methods. Based on a relatively small number of patients, no significant

  18. Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jee Young; Yoon, Young Cheol [Sungkyunkwan University, Department of Radiology, Samsung Medical Center, School of Medicine, Seoul (Korea); Yi, Sang-Kyu [Sungkyunkwan University, Department of Radiology, Samsung Medical Center, School of Medicine, Seoul (Korea); Sekye Radiologic Clinic, Daejeon (Korea); Yoo, Jaechul [Sungkyunkwan University, Department of Orthopedic Surgery, School of Medicine, Seoul (Korea); Choe, Bong-Keun [Kyung Hee University, Department of Preventive Medicine, School of Medicine, Seoul (Korea)

    2009-07-15

    To compare the diagnostic value of indirect magnetic resonance arthrography (I-MRA) with that of direct MR arthrography (D-MRA) for labral tears, rotator cuff tears, and long head of biceps tendon (LHBT) tears using a 3-T MR unit. Institutional review board approval was given; written informed consent was obtained from all patients. From November 2005 to June 2006, 19 patients (eight men and 11 women; mean age, 51 years) who had undergone both I-MRA and D-MRA underwent arthroscopic surgery. Both methods were performed in fat-saturated axial, coronal oblique, and sagittal oblique T1-weighted sequences, as well as axial and coronal oblique T2-weighted sequences. Two radiologists independently and retrospectively evaluated two sets of MRA for the diagnosis of superior and anterior labral tears, subscapularis tendon (SSC), and supraspinatus-infraspinatus tendon (SSP-ISP) tears, and LHBT tears. With the arthroscopic finding as a gold standard, we analyzed statistical differences of sensitivities and specificities between two sets of MRA and inter-observer agreement was evaluated using the kappa value. The sensitivity and specificity of I-MRA and D-MRA for reader 1 were 79/80% and 71/80%, respectively, for superior labral tears; 100/100% and 100/100%, respectively, for anterior labral tears; 64/75% and 64/100%, respectively, for SSC tears; 100/86% and 100/100%, respectively, for SSP-ISP tears; and 67/100% and 78/100%, respectively, for LHBT tears. Those of I-MRA and D-MRA for reader 2 were 86/80% and 71/100%, respectively, for superior labral tears; 100/83% and 100/100%, respectively, for anterior labral tears; 64/88% and 82/100%, respectively, for SSC tears; 92/86% and 100/100%, respectively, for SSP-ISP tears; and 78/90% and 89/100%, respectively, for LHBT tears. No significant differences were found between the methods. Inter-observer agreements were higher than moderate ({kappa} > 0.41) with both methods. Based on a relatively small number of patients, no significant

  19. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  20. Hip arthroscopy with labral repair for femoroacetabular impingement

    DEFF Research Database (Denmark)

    Dippmann, Christian; Thorborg, Kristian; Kraemer, Otto

    2014-01-01

    PURPOSE: The purpose of this study was to examine the progression of clinical outcomes 3, 6 and 12 months after hip arthroscopy with labral repair for femoroacetabular impingement (FAI). METHODS: From May 2009 to December 2011, 87 consecutive patients [55 females (median age 38, range 17-63) and 32...... males (median age 38, range 15-59)] underwent hip arthroscopy and labral repair, by the same experienced surgeon. Standardised, but unstructured, post-operative rehabilitation instructions were provided. Function and pain were evaluated using modified Harris Hip Score (mHHS) and visual analogue scale...... months with no additional changes from 6 to 12 months [22.6 (2.6)-27.9 (2.6), (n.s.)]. CONCLUSIONS: Improvements in function (mHHS) and pain (VAS) were seen in patients after hip arthroscopy with labral repair for FAI at 3, 6, and 12 months. While significant improvements occurred from 3 to 6 months...

  1. Synovial plicae of the hip: evaluation using MR arthrography in patients with hip pain

    International Nuclear Information System (INIS)

    Bencardino, Jenny T.; La Rocca Vieira, Renata; Kassarjian, Ara; Schwartz, Richard; Mellado, Jose M.; Kocher, Mininder

    2011-01-01

    The appearance and distribution of the intra-articular plicae of the hip have been addressed in few reports in the anatomic and radiological literature. This study aims to determine the prevalence of visible synovial hip plicae using MR arthrography and to measure the association of visible synovial hip plicae with MR arthrographic diagnosis of labral tears, femoroacetabular impingement, and osteoarthritis. Following institutional review board approval, 63 direct MR arthrographic examinations of the hip in 61 patients with a clinical history of hip pain were retrospectively reviewed by two experienced musculoskeletal radiologists in consensus. The following variables were measured using a binary system (0 = absent; 1 = present): labral plica, neck plica, ligamental plica, labral tear, femoroacetabular impingement, and osteoarthritis. The surgical reports and arthroscopic images of 10 patients were reviewed. Statistical analysis was performed using the Fisher's exact test. In all 63 cases at least one plica was visualized on MR-arthrographic images. Labral, neck, and ligamental plicae were found with a prevalence of 76, 97, and 78%, respectively. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis among patients with visible labral, neck, and ligamental plicae. The prevalence of labral tears, femoroacetabular impingement, and osteoarthritis in our patient population was 79, 28, and 28%, respectively. The presence of intra-articular plicae was the only MR-arthrographic finding in 5 of our 63 symptomatic cases. Visible labral, neck, and/or ligamental plicae are highly prevalent on MR-arthrographic images of the hip performed in the setting of hip pain. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis and visible labral, neck, and ligamental plicae. (orig.)

  2. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  3. Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Marc J.; Motamedi, Kambiz; Chow, Kira; Seeger, Leanne L. [David Geffen School of Medicine at UCLA, Department of Radiology, 200 UCLA Medical Plaza, Suite 165-59, Box 956952, Los Angeles, CA (United States)

    2008-01-15

    The purpose of this study was to determine the utility of fat-suppressed gradient-recalled echo (GRE) compared with conventional spin echo T1-weighted (T1W) sequences in direct shoulder MR arthrography for evaluating labral tears. Three musculoskeletal radiologists retrospectively reviewed MR arthrograms performed over a 12-month period for which surgical correlation was available. Of 180 serial arthrograms, 31 patients had surgery with a mean of 48 days following imaging. Paired coronal oblique and axial T1W or GRE sequences were analyzed by consensus for labral tear (coronal oblique two-dimensional multi-echo data image combination, 2D MEDIC; and axial three-dimensional double-echo steady-state, 3D DESS; Siemens MAGNETOM Sonata 1.5-T MR system). Interpretations were correlated with operative reports. Of 31 shoulders, 25 had labral tears at surgery. The GRE sequences depicted labral tears in 22, while T1W images depicted tears in 16 (sensitivity 88% versus 64%; p < 0.05). Subdividing the labrum, GRE was significantly more sensitive for the posterior labrum (75% versus 25%; p < 0.05) with a trend toward greater sensitivity at the anterior labrum (78% versus 56%; p = 0.157) but not significantly different for the superior labrum (50% versus 57%; p > 0.7). Specificities were somewhat lower for GRE. Thin section GRE sequences are more sensitive than T1W for the detection of anterior and posterior labral tears. As the specificity of GRE was lower, it should be considered as an adjunctive imaging sequence that may improve depiction of labral tears, particularly smaller tears, in routine MR arthrography protocols. (orig.)

  4. Loosening After Acetabular Revision

    DEFF Research Database (Denmark)

    Beckmann, Nicholas A.; Weiss, Stefan; Klotz, Matthias C.M.

    2014-01-01

    The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years...

  5. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    Full Text Available History of present illness: A 77-year-old female presented to her primary care physician (PCP with right hip pain after a mechanical fall. She did not lose consciousness or have any other traumatic injuries. She was unable to ambulate post-fall, so X-rays were ordered by her PCP. Her X-rays were concerning for a right acetabular fracture (see purple arrows, so the patient was referred to the emergency department where a computed tomography (CT scan was ordered. Significant findings: The non-contrast CT images show a minimally displaced comminuted fracture of the right acetabulum involving the acetabular roof, medial and anterior walls (red arrows, with associated obturator muscle hematoma (blue oval. Discussion: Acetabular fractures are quite rare. There are 37 pelvic fractures per 100,000 people in the United States annually, and only 10% of these involve the acetabulum. They occur more frequently in the elderly totaling an estimated 4,000 per year. High-energy trauma is the primary cause of acetabular fractures in younger individuals and these fractures are commonly associated with other fractures and pelvic ring disruptions. Fractures secondary to moderate or minimal trauma are increasingly of concern in patients of advanced age.1 Classification of acetabular fractures can be challenging. However, the approach can be simplified by remembering the three basic types of acetabular fractures (column, transverse, and wall and their corresponding radiologic views. First, column fractures should be evaluated with coronally oriented CT images. This type of fracture demonstrates a coronal fracture line running caudad to craniad, essentially breaking the acetabulum into two halves: a front half and a back half. Secondly, transverse fractures should be evaluated by sagittally oriented CT images. By definition, a transverse fracture separates the acetabulum into superior and inferior halves with the fracture line extending from anterior to posterior

  6. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Clement M.L. [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland); University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H. [University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Ruckstuhl, Thomas; Bouaicha, Samy [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland)

    2011-11-15

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE (<20 ) or the AI (>12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  7. Reverse Total Shoulder Arthroplasty as Treatment for Rotator Cuff-Tear Arthropathy and Shoulder Dislocations in an Elderly Male with Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    John G. Skedros

    2017-01-01

    Full Text Available We report the case of a 70-year-old male with Parkinson’s disease (PD and recurrent traumatic left shoulder dislocations. This case is rare because (1 he had a massive irreparable rotator cuff tear and end-stage arthritis (i.e., rotator cuff-tear arthropathy of the same shoulder and (2 his shoulder was ultimately reconstructed with a reverse total shoulder arthroplasty (RTSA. His first dislocation occurred after a fall. Recurrent shoulder dislocations occurred despite successful closed reduction and physical therapy. Initial surgical treatment included an open capsular-labral reconstruction; RTSA was not an ideal option because of the presumed risk of failure from PD-related dyskinesias. However, the capsular-labral reconstruction failed after he lost balance and stumbled but did not fall. A RTSA was then done which restored the patient’s shoulder stability and greatly improved his pain. At final follow-up two years later, he reported pain relief and improved function. This was partially attributed to the fact that he had moved to an assisted living center. He also began using an electric wheelchair one year after the RTSA. We report this case because of the unusual set of conditions and circumstances, namely, the implantation of a RTSA in a patient with PD and shoulder instability.

  8. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  9. Labral-Ligamentous Complex of the Shoulder. Evaluation with double oblique axial MR arthrography. Technical Note

    International Nuclear Information System (INIS)

    Sasaki, Taisuke; Saito, Y.; Yodono, H.; Prado, G.L.M.; Miura, H.; Itabashi, Y.; Ishibashi, Y.

    2003-01-01

    Purpose: To assess the ability of double oblique axial (DOA) MR arthrography in evaluating labral-ligamentous complex compared with conventional axial (CA) MR arthrography. Material and Methods: MR arthrography of 51 shoulders, subsequently examined with arthroscopy, were retrospectively reviewed. DOA imaging was performed in all 51 shoulders and both DOA and CA imaging in 37 using a 1.5 T unit with gradient recalled-echo T2*-weighted sequences. DOA imaging was performed using perpendicular planes to the long axis of the glenoid fossa obtained by an oblique sagittal scout image. We compared the ability of DOA with that of CA MR arthrography to assess labral injuries and to demonstrate the whole length of the anterior band of the inferior glenohumeral ligament (AIGHL), which were shown to be intact by arthroscopy. Results: For anterior labral injuries, sensitivity and specificity were 87% and 93% with CA, and 94% and 100% with DOA imaging, respectively. For posterior labral injuries, sensitivity and specificity were 47% and 100% with CA, and 79% and 96% with DOA imaging, respectively. There were no statistically significant differences between CA and DOA images, except for the ability to diagnose posterior labral injuries, where DOA imaging had a significant superior sensitivity (p = 0.0327). DOA images also demonstrated the whole length of the intact AIGHL in 10 of 11 shoulders, while CA imaging showed this in only 3 of 11. Conclusion: DOA imaging was equal or better than CA imaging for evaluating the labral-ligamentous complex

  10. Acetabular fractures: anatomic and clinical considerations.

    Science.gov (United States)

    Lawrence, David A; Menn, Kirsten; Baumgaertner, Michael; Haims, Andrew H

    2013-09-01

    Classifying acetabular fractures can be an intimidating topic. However, it is helpful to remember that there are only three basic types of acetabular fractures: column fractures, transverse fractures, and wall fractures. Within this framework, acetabular fractures are classified into two broad categories: elementary or associated fractures. We will review the osseous anatomy of the pelvis and provide systematic approaches for reviewing both radiographs and CT scans to effectively evaluate the acetabulum. Although acetabular fracture classification may seem intimidating, the descriptions and distinctions discussed and shown in this article hopefully make the topic simpler to understand. Approach the task by recalling that there are only three basic types of acetabular fractures: column fractures (coronally oriented on CT images), transverse fractures (sagittally oriented on CT images), and wall fractures (obliquely oriented on CT images). We have provided systematic approaches for reviewing both conventional radiographs and CT scans to effectively assess the acetabulum. The clinical implications of the different fracture patterns have also been reviewed because it is critically important to include pertinent information for our clinical colleagues to provide the most efficient and timely clinical care.

  11. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  12. Total hip reconstruction in acetabular dysplasia : a finite element study

    NARCIS (Netherlands)

    Schüller, H.M.; Dalstra, M.; Huiskes, H.W.J.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  13. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  14. The role of arthroscopy in the dysplastic hip—a systematic review of the intra-articular findings, and the outcomes utilizing hip arthroscopic surgery

    Science.gov (United States)

    Jo, Suenghwan; Lee, Sang Hong; Wang, Sung Il; Smith, Bjorn; O’Donnell, John

    2016-01-01

    Acetabular dysplasia is one of the most common sources of hip arthritis. With the recent innovation in hip arthroscopy, the question has been raised whether arthroscopy can be used to treat dysplastic hip conditions. The purposes of this systematic review are (i) describe the prevalence of intra-articular pathologies and (ii) report the outcomes of dysplastic hip treatment with hip arthroscopy as a sole treatment. Medical databases were searched for articles including arthroscopic findings and treatment of dysplastic hip with predetermined criteria. PubMed, Ovid database and CINAHL (Cumulative Index to Nursing and Allied Health Literature) were searched up until 7 January 2015. Two reviewers independently assess the eligibility of retrieved studies using titles, abstracts and full-text articles. Thirteen studies were eligible to be included for the systematic review. Overall, labral tear was the most common pathology with a prevalence rate of 77.3%. All of the four studies describing arthroscopic treatment for only borderline dysplasia reported favorable outcome. With regard to more severely dysplastic hips, two out of three studies reported acceptable outcomes while one study reported negative results. This review indicates that intra-articular pathology is commonly observed in symptomatic dysplastic hips with a labral tear being the most common pathology. Arthroscopic treatment of borderline dysplasia could provide benefits whereas treatment of more dysplastic hips is controversial. Nevertheless, there is a lack of evidence for using arthroscopy alone in hips with a center edge angle <20°. Level IV, systematic review of Level IV studies. PMID:27583155

  15. Technical innovation: digital tomosynthesis of the hip following intra-articular administration of contrast

    International Nuclear Information System (INIS)

    Gazaille, Roland E.; Flynn, Michael J.; Page, Walter; Finley, Sonia; Holsbeeck, Marnix van

    2011-01-01

    To demonstrate the clinical use of digital tomosynthesis in the depiction of labral and chondral pathology in the setting of post-operative CAM-type impingement of the hip following intra-articular administration of dilute iodinated contrast. We present images from a 46 year-old African American female with suspected CAM-type femoroacetabular impingement (FAI) following percutaneous pinning of the right hip for slipped capital femoral epiphysis (SCFE). A partial tear of the labrum and clinically significant acetabular chondral abnormalities were demonstrated with the use of digital tomosynthesis with superb anatomic detail. Digital tomosynthesis can be of great clinical utility and can depict pathology in superb anatomic detail, particularly in situations in which MRI is not available as well as under circumstances in which artifact due to orthopedic hardware is of concern as shown in this case. (orig.)

  16. The Diagnostic Value of the Vacuum Phenomenon during Hip Arthroscopy

    Science.gov (United States)

    Rath, Ehud; Gortzak, Yair; Schwarzkopf, Ran; Benkovich, Vadim; Cohen, Eugene; Atar, Dan

    2011-01-01

    The diagnostic value of the vacuum phenomenon between the femoral head and the acetabulum, and time frame of its occurrence after application of traction is an important clinical question. The resulting arthrogram may outline the shape, location, and extent of cartilage lesions prior to arthroscopy of the hip joint. The presence, duration, and diagnostic information of the vacuum phenomenon were evaluated in 24 hips that underwent arthroscopy. The operative diagnosis was compared to the results of imaging studies and to findings obtained during a traction trial prior to arthroscopy. Indications for arthroscopy included avascular necrosis, labral tears, loose bodies, osteoarthrosis, and intractable hip pain. In 22 hips the vacuum phenomenon developed within 30 seconds after application of traction. The most important data obtained from the vacuum phenomenon was the location and extent of femoral head articular cartilage detachment and the presence of nonossified loose bodies. The vacuum phenomenon did not reveal labral or acetabular cartilage pathology in any of these patients. The vacuum phenomenon obtained during the trial of traction can add valuable information prior to hip arthroscopy. Femoral head articular cartilage detachment was best documented by this method. The hip arthroscopist should utilize this diagnostic window routinely prior to hip arthroscopy. PMID:24977068

  17. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    Energy Technology Data Exchange (ETDEWEB)

    Crespo-Rodríguez, Ana M., E-mail: anacresporodriguez@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); De Lucas-Villarrubia, Jose C., E-mail: jclucasv@hotmail.com [Department of Orthopaedics and Traumatology at the Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Pastrana-Ledesma, Miguel, E-mail: m.pastrana@telefonica.net [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Hualde-Juvera, Ana, E-mail: ana.hualdej@salud.madrid.org [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Méndez-Alonso, Santiago, E-mail: smendez.sma@gmail.com [Department of Radiology, Hospital Universitario Puerta de Hierro Majadahonda, c/ Joaquín Rodrigo 2, Majadahonda 28222, Madrid (Spain); Padron, Mario, E-mail: mario.padron@clinicacemtro.com [Department of Radiology, Clínica Cemtro, Avda Ventisquero de la Condesa 42 Madrid 28035, Madrid (Spain)

    2017-03-15

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  18. The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement

    International Nuclear Information System (INIS)

    Crespo-Rodríguez, Ana M.; De Lucas-Villarrubia, Jose C.; Pastrana-Ledesma, Miguel; Hualde-Juvera, Ana; Méndez-Alonso, Santiago; Padron, Mario

    2017-01-01

    Highlights: • High resolution sequences at 3-T MRI extend accuracy in hip assessment without any need for intra-articular injection of contrast media. • As compared to 1.5-T MRA, 3-T non-contrast MRI of the hip improves the patient experience and avoids the potential risks of an invasive procedure and contrast media. • Avoiding the need for arthrographic procedures in the Radiology Department improves patient throughput and reduces costs. - Abstract: Objective: The aim of this study was to evaluate the diagnostic accuracy of 3-T non-contrast MRI versus 1.5-T MRA for assessing labrum and articular cartilage lesions in patients with clinical suspicion of femoro-acetabular impingement (FAI). Subjects and methods: Fifty patients (thirty men and twenty women, mean age 42.5 years) underwent 1.5-T MRA, 3-T MRI and arthroscopy on the same hip. An optimized high-resolution proton density spin echo pulse sequence was included in the 3-T non-contrast MRI protocol. Results: The 3-T non-contrast MRI identified forty-two of the forty-three arthroscopically proven tears at the labral-chondral transitional zone (sensitivity, 97.7%; specificity, 100%; positive predictive value (PPV), 100%; negative predictive value (NPV), 87.5%; accuracy 98%). With 1.5-T MRA, forty-four tears were diagnosed. However, there was one false positive (sensitivity, 100%; specificity, 85.7%; PPV, 97.7%; NPV, 100%; accuracy 98%). Agreement between arthroscopy and MRI, whether 3-T non-contrast MRI or 1.5-T MRA, as to the degree of chondral lesion in the acetabulum was reached in half of the patients and in the femur in 76% of patients. Conclusion: Non-invasive assessment of the hip is possible with 3-T MR magnet. 3-T non-contrast MRI could replace MRA as the workhorse technique for assessing hip internal damage. MRA would then be reserved for young adults with a strong clinical suspicion of FAI but normal findings on 3-T non-contrast MRI. When compared with 1.5-T MRA, optimized sequences with 3-T non

  19. Acetabular Dysplasia and Surgical Approaches Other Than Direct Anterior Increases Risk for Malpositioning of the Acetabular Component in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Gromov, Kirill; Greene, Meridith E; Huddleston, James I

    2016-01-01

    BACKGROUND: Persistent acetabular dysplasia (AD) after periacetabular osteotomy has been hypothesized to increase the risk for malpositioning of the acetabular component. In this study, we investigate whether AD is an independent risk factor for cup malpositioning during primary total hip...... arthroplasty (THA). METHODS: Patient demographics, surgical approach, presence of AD assessed using the lateral center-edge angle, and acetabular cup positioning determined using Martell Hip Analysis Suite were investigated in 836 primary THA patients enrolled in a prospective multicenter study. RESULTS: We...

  20. [Quantification of acetabular coverage in normal adult].

    Science.gov (United States)

    Lin, R M; Yang, C Y; Yu, C Y; Yang, C R; Chang, G L; Chou, Y L

    1991-03-01

    Quantification of acetabular coverage is important and can be expressed by superimposition of cartilage tracings on the maximum cross-sectional area of the femoral head. A practical Autolisp program on PC AutoCAD has been developed by us to quantify the acetabular coverage through numerical expression of the images of computed tomography. Thirty adults (60 hips) with normal center-edge angle and acetabular index in plain X ray were randomly selected for serial drops. These slices were prepared with a fixed coordination and in continuous sections of 5 mm in thickness. The contours of the cartilage of each section were digitized into a PC computer and processed by AutoCAD programs to quantify and characterize the acetabular coverage of normal and dysplastic adult hips. We found that a total coverage ratio of greater than 80%, an anterior coverage ratio of greater than 75% and a posterior coverage ratio of greater than 80% can be categorized in a normal group. Polar edge distance is a good indicator for the evaluation of preoperative and postoperative coverage conditions. For standardization and evaluation of acetabular coverage, the most suitable parameters are the total coverage ratio, anterior coverage ratio, posterior coverage ratio and polar edge distance. However, medial coverage and lateral coverage ratios are indispensable in cases of dysplastic hip because variations between them are so great that acetabuloplasty may be impossible. This program can also be used to classify precisely the type of dysplastic hip.

  1. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  2. Modified Harrington Procedure for Acetabular Insuficiency Due to Metastatic Malignant Disease

    Directory of Open Access Journals (Sweden)

    WI Faisham

    2009-05-01

    Full Text Available Extensive peri-acetabular osteolysis caused by malignant disease process is a major surgical challenge as conventional hip arthroplasty is not adequate. We describe a modified use of the Harrington procedure for acetabular insufficiency secondary to metastatic disease in twelve patients. The procedures include application of multiple threaded pins to bridge the acetabular columns, anti-protrusio cage and cemented acetabular cup. Eleven patients were able to walk pain free and achieved a mean Musculoskeletal Tumour Society Functional Score of 80 (range, 68 to 86.

  3. Validation of a Dry Model for Assessing the Performance of Arthroscopic Hip Labral Repair.

    Science.gov (United States)

    Phillips, Lisa; Cheung, Jeffrey J H; Whelan, Daniel B; Murnaghan, Michael Lucas; Chahal, Jas; Theodoropoulos, John; Ogilvie-Harris, Darrell; Macniven, Ian; Dwyer, Tim

    2017-07-01

    Arthroscopic hip labral repair is a technically challenging and demanding surgical technique with a steep learning curve. Arthroscopic simulation allows trainees to develop these skills in a safe environment. The purpose of this study was to evaluate the use of a combination of assessment ratings for the performance of arthroscopic hip labral repair on a dry model. Cross-sectional study; Level of evidence, 3. A total of 47 participants including orthopaedic surgery residents (n = 37), sports medicine fellows (n = 5), and staff surgeons (n = 5) performed arthroscopic hip labral repair on a dry model. Prior arthroscopic experience was noted. Participants were evaluated by 2 orthopaedic surgeons using a task-specific checklist, the Arthroscopic Surgical Skill Evaluation Tool (ASSET), task completion time, and a final global rating scale. All procedures were video-recorded and scored by an orthopaedic fellow blinded to the level of training of each participant. The internal consistency/reliability (Cronbach alpha) using the total ASSET score for the procedure was high (intraclass correlation coefficient > 0.9). One-way analysis of variance for the total ASSET score demonstrated a difference between participants based on the level of training ( F 3,43 = 27.8, P 0.9). The results of this study demonstrate that the use of dry models to assess the performance of arthroscopic hip labral repair by trainees is both valid and reliable. Further research will be required to demonstrate a correlation with performance on cadaveric specimens or in the operating room.

  4. Image research on acetabular teardrop shadow by X-ray plain-film and CT

    International Nuclear Information System (INIS)

    Wang Xiaoxuan; Zhai Yuejie; Yu Hongguang; Yang Yijun; Zhang Daiwei; Chen Aili; Song Quanjun

    2001-01-01

    Objective: To evaluate the anatomical structure of bone in the formation of acetabular teardrop shadow. Methods: The acetabular teardrop shadow of the X-ray plain-film in 100 children and 300 adults, and of CT in 43 cases were analysed, measured and compared. Results: In children, teardrop shadow appeared 'U' in 80.00%, 14.00% in teardrop, 6.00% in line. In adult teardrop shadow appeared 'U' in 41.33%, 53.33% in teardrop, 5.34% in line. There were significant differences between children and adult in the frequency of 'U' and teardrop (x 2 = 43.34, P 2 = 45.62, P < 0.01). In children, inpeduncle of teardrop shadow was formed of middle 1/3 substantia-line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 substantia-line of bottom of acetabular. In adult, inpeduncle was formed of middle 1/3 or back 1/3 substantia line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 or back 1/3 substantia-line of bottom of acetabular. Conclusion: In children, acetabular teardrop shadow was mainly formed of middle 1/3 bone of acetabular concavity. In adult, middle 1/3 or back 1/3 bone of acetabular concavity contribute to the shadow. The ahead 1/3 bone of acetabular concavity is not involved

  5. Diagnosis of superior labral lesions: comparison of noncontrast MRI with indirect MR arthrography in unexercised shoulders

    International Nuclear Information System (INIS)

    Dinauer, Philip A.; Flemming, Donald J.; Murphy, Kevin P.; Doukas, William C.

    2007-01-01

    To prospectively compare the accuracy of noncontrast magnetic resonance imaging (MRI) with indirect MR arthrography (I-MRa) of unexercised shoulders for diagnosis of superior glenoid labral lesions. Institutional Review Board approval and patient informed consent were obtained for this prospective study. Superior labral findings on shoulder MRI and unexercised I-MRa studies of 104 patients were correlated with findings at arthroscopic shoulder surgery. Two musculoskeletal radiologists independently reviewed the two sets of MR images while blinded to arthroscopic results. For each radiologist, the McNemar test was used to detect statistically significant differences between techniques. The superior labrum was intact in 24 and abnormal in 80 subjects. For detection of superior labral lesions by each radiologist, I-MRa was more sensitive (84-91%) than MRI (66-85%), with statistically significant improvement in sensitivity for one reader (p = 0.003). However, I-MRa was less specific (58-71%) than MRI (75-83%). Overall, accuracy was slightly improved on I-MRa (78-86%) compared with MRI (70-83%), but this difference was not statistically significant for either reader. Compared with noncontrast MRI, I-MRa was more sensitive for diagnosis of superior glenoid labral lesions. However, the diagnostic value of I-MRa in shoulders remaining at rest is potentially limited by decreased specificity of the technique. (orig.)

  6. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  7. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  8. Plain film analysis of acetabular fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik Hospital, Pusan (Korea, Republic of)

    1986-02-15

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%)

  9. Plain film analysis of acetabular fracture

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1986-01-01

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%).

  10. The nerve endings of the acetabular labrum.

    Science.gov (United States)

    Kim, Y T; Azuma, H

    1995-11-01

    The nerve endings of the human acetabular labrum were investigated. Twenty-three acetabular labra were obtained from 24 fresh human cadavers, stained with Suzuki's silver impregnation and an immunohistochemical technique for neurogenic specific protein S-100, and examined by light and electron microscopy. Ramified free nerve endings were seen in all specimens by silver staining, and also were observed by the immunohistochemical technique for S-100 protein. Sensory nerve end organs, such as a Vater-Pacini corpuscle, Golgi-Mazzoni corpuscle, Ruffini corpuscle, and articular corpuscle (Krause corpuscle), were observed by silver staining. Collagen fibers were scattered sparsely in the superficial layer of the labrum, and nerve endings were observed mostly in this region. Collagen fibers were sparse, and nerve endings also were observed in some regions among the collagen fiber bundles in the inner layer. Innervation of the acetabular labrum was confirmed in this study, suggesting that nerve endings in the labrum may be involved in nociceptive and proprioceptive mechanisms.

  11. SLAP lesions: Anatomy, clinical presentation, MR imaging diagnosis and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Debra [University of California San Diego, Department of Radiology, 200 W. Arbor Drive, San Diego, CA 92103 (United States); VA Healthcare System San Diego, Department of Radiology, 3350 La Jolla Village Drive, La Jolla, CA 92161 (United States); MedRay Imaging and Fraser Health Authority, Vancouver, BC (Canada)], E-mail: cbchung@ucsd.edu; Mohana-Borges, Aurea; Borso, Maya; Chung, Christine B. [University of California San Diego, Department of Radiology, 200 W. Arbor Drive, San Diego, CA 92103 (United States); VA Healthcare System San Diego, Department of Radiology, 3350 La Jolla Village Drive, La Jolla, CA 92161 (United States)

    2008-10-15

    ABSTRACT: Superior labral anterior posterior (SLAP) tears are an abnormality of the superior labrum usually centered on the attachment of the long head of the biceps tendon. Tears are commonly caused by repetitive overhead motion or fall on an outstretched arm. SLAP lesions can lead to shoulder pain and instability. Clinical diagnosis is difficult thus imaging plays a key diagnostic role. The normal anatomic variability of the capsulolabral complex can make SLAP lesions a diagnostic challenge. Concurrent shoulder injuries are often present including rotator cuff tears, cystic changes or marrow edema in the humeral head, capsular laxity, Hill-Sachs or Bankart lesion. The relevant anatomy, capsulolabral anatomic variants, primary and secondary findings of SLAP tears including MR arthrography findings, types of SLAP lesions and a practical approach to labral lesions are reviewed.

  12. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  13. Axillary arthrotomography of the glenoid labrum

    International Nuclear Information System (INIS)

    Kleinman, P.K.; Kanzaria, P.K.; Goss, T.P.; Pappas, A.M.

    1984-01-01

    In a study of 67 shoulders evaluated by axillary arthrotomography, tears of the glenoid labrum were accurately detected in all 26 surgically confirmed cases. One false-positive case was identified in the five patients without labral tears; there were no false-negative cases. Only 40% of the patients had clinical evidence of subluxation or dislocation. Axillary arthrotomography provides important information about the integrity of the labrum that may be helpful in planning surgery for patients without clinical subluxation or dislocation but with pain, clicking, or vague shoulder discomfort secondary to labral pathology (functional instability)

  14. Acetabular paralabral cyst causing compression of the sciatic nerve

    Directory of Open Access Journals (Sweden)

    Caoimhe Byrne, MB BCh BAO

    2017-12-01

    Full Text Available Acetabular paralabral cysts are common. They vary in their clinical presentation and may be asymptomatic or cause pain and restriction at the hip joint. In rare instances they may cause symptoms by compressing local neurovascular structures. We report a case of symptomatic compression of the sciatic nerve by a posteriorly displaced acetabular paralabral cyst.

  15. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    International Nuclear Information System (INIS)

    Jung, Jin Young; Yoon, Young Cheol; Cha, Dong Ik; Yoo, Jae-Chul; Jung, Jee Young

    2013-01-01

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of the SSC tendon and anterior portion of the SSP tendon were 81.0%, 100%, and 86

  16. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  17. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  18. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  19. Distal clavicular osteolysis: MR evidence for subchondral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kassarjian, Ara; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Radiology, Yawkey Center, Boston, MA (United States); Llopis, Eva [Hospital de la Ribera, Department of Radiology, Valencia (Spain)

    2007-01-15

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  20. Distal clavicular osteolysis: MR evidence for subchondral fracture

    International Nuclear Information System (INIS)

    Kassarjian, Ara; Palmer, William E.; Llopis, Eva

    2007-01-01

    To investigate the association between distal clavicular osteolysis and subchondral fractures of the distal clavicle at MRI. This study was approved by the hospital human research committee, which waived the need for informed consent. Three radiologists retrospectively analyzed 36 shoulder MR examinations in 36 patients with imaging findings of distal clavicular osteolysis. The presence of a subchondral fracture of the distal clavicle, abnormalities of the acromioclavicular joint, rotator cuff tears and labral tears were assessed by MRI. These cases were then compared with 36 age-matched controls. At MRI, 31 of 36 patients (86%) had a subchondral line within the distal clavicular edema, consistent with a subchondral fracture. Of the 36 patients, 32 (89%) had fluid in the acromioclavicular joint, while 27 of 36 patients (75%) had cysts or erosions in the distal clavicle. There were 13 patients (36%) with associated labral tears, while eight patients (22%) had partial-thickness rotator cuff tears. In the control group one of 36 (3%) had a subchondral line (P<0.05), while ten of 36 (28%) had rotator cuff tears and 13 of 36 (36%) had labral tears. These latter two were not statistically significant between the groups. A distal clavicular subchondral fracture is a common finding in patients with imaging evidence of distal clavicular osteolysis. These subchondral fractures may be responsible for the propensity of findings occurring on the clavicular side of the acromioclavicular joint. (orig.)

  1. CUSTOM TRIFLANGE ACETABULAR COMPONENTS IN REVISION HIP REPLACEMENT (EXPERIENCE REVIEW

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2017-01-01

    Full Text Available Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months. 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.

  2. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro [Asahikawa Medical College, Department of Orthopaedic Surgery, Asahikawa (Japan); Minami, Akio [Hokkaido University School of Medicine, Department of Orthopaedic Surgery, Sapporo (Japan)

    2009-02-15

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  3. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro; Minami, Akio

    2009-01-01

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  4. Sham surgery versus labral repair or biceps tenodesis for type II SLAP lesions of the shoulder: a three-armed randomised clinical trial.

    Science.gov (United States)

    Schrøder, Cecilie Piene; Skare, Øystein; Reikerås, Olav; Mowinckel, Petter; Brox, Jens Ivar

    2017-12-01

    Labral repair and biceps tenodesis are routine operations for superior labrum anterior posterior (SLAP) lesion of the shoulder, but evidence of their efficacy is lacking. We evaluated the effect of labral repair, biceps tenodesis and sham surgery on SLAP lesions. A double-blind, sham-controlled trial was conducted with 118 surgical candidates (mean age 40 years), with patient history, clinical symptoms and MRI arthrography indicating an isolated type II SLAP lesion. Patients were randomly assigned to either labral repair (n=40), biceps tenodesis (n=39) or sham surgery (n=39) if arthroscopy revealed an isolated SLAP II lesion. Primary outcomes at 6 and 24 months were clinical Rowe score ranging from 0 to 100 (best possible) and Western Ontario Shoulder Instability Index (WOSI) ranging from 0 (best possible) to 2100. Secondary outcomes were Oxford Instability Shoulder Score, change in main symptoms, EuroQol (EQ-5D and EQ-VAS), patient satisfaction and complications. There were no significant between-group differences at any follow-up in any outcome. Between-group differences in Rowe scores at 2 years were: biceps tenodesis versus labral repair: 1.0 (95% CI -5.4 to 7.4), p=0.76; biceps tenodesis versus sham surgery: 1.6 (95% CI -5.0 to 8.1), p=0.64; and labral repair versus sham surgery: 0.6 (95% CI -5.9 to 7.0), p=0.86. Similar results-no differences between groups-were found for WOSI scores. Postoperative stiffness occurred in five patients after labral repair and in four patients after tenodesis. Neither labral repair nor biceps tenodesis had any significant clinical benefit over sham surgery for patients with SLAP II lesions in the population studied. ClinicalTrials.gov identifier: NCT00586742. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Correlation of clinical and magnetic resonance imaging findings in hips of elite female ballet dancers.

    Science.gov (United States)

    Duthon, Victoria B; Charbonnier, Caecilia; Kolo, Frank C; Magnenat-Thalmann, Nadia; Becker, Christophe D; Bouvet, Cindy; Coppens, Elia; Hoffmeyer, Pierre; Menetrey, Jacques

    2013-03-01

    To understand why professional female ballet dancers often complain of inguinal pain and experience early hip osteoarthritis (OA). Goals were to examine clinical and advanced imaging findings in the hips of dancers compared with those in a matched cohort of nondancers and to assess the femoral head translation in the forward split position using magnetic resonance imaging (MRI). Twenty professional female ballet dancers and 14 active healthy female individuals matched for age (control group) completed a questionnaire on hip pain and underwent hip examination with impingement tests and measurement of passive hip range of motion (ROM). All had a pelvic 1.5 T MRI in the back-lying position to assess femoroacetabular morphologic features and lesions. For the dancers, additional MR images were acquired in the split position to evaluate femoroacetabular congruency. Twelve of 20 dancers complained of groin pain only while dancing; controls were asymptomatic. Dancers' passive hip ROM was normal. No differences in α neck angle, acetabular depth, acetabular version, and femoral neck anteversion were found between dancers and controls. MRI of dancers while performing splits showed a mean femoral head subluxation of 2.05 mm. MRI of dancers' hips showed labral tears, cartilage thinning, and herniation pits, located in superior and posterosuperior positions. Lesions were the same for symptomatic and asymptomatic dancers. Controls had proportionally the same number of labral lesions but in an anterosuperior position. They also had 2 to 3 times fewer cartilage lesions and pits than did dancers. The results of our study are consistent with our hypothesis that repetitive extreme movements can cause femoral head subluxations and femoroacetabular abutments in female ballet dancers with normal hip morphologic features, which could result in early OA. Pathologic changes seen on MRI were symptomatic in less than two thirds of the dancers. Level IV, therapeutic case series. Copyright

  6. Functional evaluation of repairs to circumferential labral lesions of the glenoid - Case series

    Directory of Open Access Journals (Sweden)

    Alexandre Tadeu do Nascimento

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results among patients undergoing arthroscopic repair of circumferential labral lesions. METHODS: This was a retrospective study on 10 patients who underwent arthroscopic repair to circumferential labral lesions of the shoulder, between September 2012 and September 2015. The patients were evaluated by means of the Carter-Rowe score, DASH score, UCLA score, visual analog scale (VAS for pain and Short-Form 36 (SF36. The average age at surgery was 29.6 years. The mean follow-up was 27.44 months (range: 12-41.3. RESULTS: The mean score was 16 points for DASH; 32 points for UCLA, among which six patients (60% had excellent results, three (30% good and one (10% poor; 1.8 points for VAS, among which nine patients (90% had minor pain and one (10% moderate pain; 79.47 for SF-36; and 92.5 for Carter-Rowe, among which nine patients (90% had excellent results and one (10% good. Joint degeneration was present in one case (10%, of grade 1. We did not observe any significant complications, except for grade 1 glenohumeral arthrosis, which one patient developed after the operation. CONCLUSION: Arthroscopic repair of circumferential labral lesions of the shoulder through use of absorbable anchors is effective, with improvements in all scores applied, and it presents low complication rates. Cases associated with glenohumeral dislocation have lower long-term residual pain.

  7. Acetabular fractures: what radiologists should know and how 3D CT can aid classification.

    Science.gov (United States)

    Scheinfeld, Meir H; Dym, Akiva A; Spektor, Michael; Avery, Laura L; Dym, R Joshua; Amanatullah, Derek F

    2015-01-01

    Correct recognition, description, and classification of acetabular fractures is essential for efficient patient triage and treatment. Acetabular fractures may result from high-energy trauma or low-energy trauma in the elderly. The most widely used acetabular fracture classification system among radiologists and orthopedic surgeons is the system of Judet and Letournel, which includes five elementary (or elemental) and five associated fractures. The elementary fractures are anterior wall, posterior wall, anterior column, posterior column, and transverse. The associated fractures are all combinations or partial combinations of the elementary fractures and include transverse with posterior wall, T-shaped, associated both column, anterior column or wall with posterior hemitransverse, and posterior column with posterior wall. The most unique fracture is the associated both column fracture, which completely dissociates the acetabular articular surface from the sciatic buttress. Accurate categorization of acetabular fractures is challenging because of the complex three-dimensional (3D) anatomy of the pelvis, the rarity of certain acetabular fracture variants, and confusing nomenclature. Comparing a 3D image of the fractured acetabulum with a standard diagram containing the 10 Judet and Letournel categories of acetabular fracture and using a flowchart algorithm are effective ways of arriving at the correct fracture classification. Online supplemental material is available for this article. (©)RSNA, 2015.

  8. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  9. Optimization of technique for insertion of implants at the supra-acetabular corridor in pelvis and acetabular surgery.

    Science.gov (United States)

    Tosounidis, Theodoros H; Mauffrey, Cyril; Giannoudis, Peter V

    2018-01-01

    The technique for application of implants at the sciatic buttress has been well described in the pelvic and acetabular fracture reconstruction literature. We described a new use of the inlet-obturator oblique view for the identification of the anterior inferior iliac spine, which is the entry point of implants, and we provide a detailed fluoroscopic and radiographic description of this view. A small series of 15 patients who underwent an application of an anterior inferior pelvic external (supra-acetabular) fixator via this technique is presented. We consider the use of the obturator oblique for the identification of the entry point unnecessary, and we advocate for the use of only the inlet-obturator oblique and iliac oblique views when implants are applied to the sciatic buttress.

  10. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  11. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  12. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    Science.gov (United States)

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum.

  13. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  14. Imaging findings of femoroacetabular impingement syndrome

    International Nuclear Information System (INIS)

    Beall, Douglas P.; Sweet, Clifford F.; Martin, Hal D.; Lastine, Craig L.; Grayson, David E.; Ly, Justin Q.; Fish, Jon R.

    2005-01-01

    Femoroacetabular impingement syndrome (FAI) is a pathologic entity which can lead to chronic symptoms of pain, reduced range of motion in flexion and internal rotation, and has been shown to correlate with degenerative arthritis of the hip. History, physical examination, and supportive radiographic findings such as evidence of articular cartilage damage, acetabular labral tearing, and early-onset degenerative changes can help physicians diagnose this entity. Several pathologic changes of the femur and acetabulum are known to predispose patients to develop FAI and recognition of these findings can ultimately lead to therapeutic interventions. The two basic mechanisms of impingement - cam impingement and pincer impingement - are based on the type of anatomic anomaly contributing to the impingement process. These changes can be found on conventional radiography, MR imaging, and CT examinations. However, the radiographic findings of this entity are not widely discussed and recognized by physicians. In this paper, we will introduce these risk factors, the proposed supportive imaging criteria, and the ultimate interventions that can help alleviate patients' symptoms. (orig.)

  15. Imaging findings of femoroacetabular impingement syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Beall, Douglas P.; Sweet, Clifford F.; Martin, Hal D.; Lastine, Craig L.; Grayson, David E.; Ly, Justin Q.; Fish, Jon R. [University of Oklahoma Health Sciences Center, Department of Radiologal Sciences, Oklahoma City (United States)

    2005-11-01

    Femoroacetabular impingement syndrome (FAI) is a pathologic entity which can lead to chronic symptoms of pain, reduced range of motion in flexion and internal rotation, and has been shown to correlate with degenerative arthritis of the hip. History, physical examination, and supportive radiographic findings such as evidence of articular cartilage damage, acetabular labral tearing, and early-onset degenerative changes can help physicians diagnose this entity. Several pathologic changes of the femur and acetabulum are known to predispose patients to develop FAI and recognition of these findings can ultimately lead to therapeutic interventions. The two basic mechanisms of impingement - cam impingement and pincer impingement - are based on the type of anatomic anomaly contributing to the impingement process. These changes can be found on conventional radiography, MR imaging, and CT examinations. However, the radiographic findings of this entity are not widely discussed and recognized by physicians. In this paper, we will introduce these risk factors, the proposed supportive imaging criteria, and the ultimate interventions that can help alleviate patients' symptoms. (orig.)

  16. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    Science.gov (United States)

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  17. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  18. High frequency of labral pathology in dysplastic hips with a CE angle between 20-25

    DEFF Research Database (Denmark)

    Jakobsen, Stig Storgaard; Hartig-Andreasen, Charlotte; Mikkelsen, Lone Rømer

    Background: Hip dysplasia becomes symptomatic due to labral pathology and secondary muscular pain. A CE angle dysplasia in PAO centres in Denmark. However, it is debated whether a CE angle between 20 and 25 is borderline. Purpose / Aim of Study: We aimed...... to investigate the degree of labral pathology in symptomatic patients with CE between 20 and 25 compared with patients with CE hips) with a mean age 34.1 years (range 14.5- 58.9 years) consecutively scheduled for PAO due to symptomatic DDH were enrolled...... in the study. Five patients were excluded from the study and four patients failed to show up at follow- up, hence 90 patients were evaluated. Indication for PAO were persisting hip pain, a center-edge angle of Wiberg 15, hip flexion

  19. Extreme hip motion in professional ballet dancers: dynamic and morphological evaluation based on magnetic resonance imaging.

    Science.gov (United States)

    Kolo, Frank C; Charbonnier, Caecilia; Pfirrmann, Christian W A; Duc, Sylvain R; Lubbeke, Anne; Duthon, Victoria B; Magnenat-Thalmann, Nadia; Hoffmeyer, Pierre; Menetrey, Jacques; Becker, Christoph D

    2013-05-01

    To determine the prevalence of femoroacetabular impingement (FAI) of the cam or pincer type based on magnetic resonance imaging (MRI) in a group of adult female professional ballet dancers, and to quantify, in vivo, the range of motion (ROM) and congruence of the hip joint in the splits position. Institutional review board approval and informed consent from each volunteer were obtained. Thirty symptomatic or asymptomatic adult female professional ballet dancers (59 hips) and 14 asymptomatic non-dancer adult women (28 hips, control group) were included in the present study. All subjects underwent MRI in the supine position, while, for the dancers, additional images were acquired in the splits position. Labral abnormalities, cartilage lesions, and osseous abnormalities of the acetabular rim were assessed at six positions around the acetabulum. A morphological analysis, consisting of the measurement of the α angle, acetabular depth, and acetabular version, was performed. For the dancers, ROM and congruency of the hip joint in the splits position were measured. Acetabular cartilage lesions greater than 5 mm were significantly more frequent in dancer's hips than in control hips (28.8 vs 7.1%, p = 0.026), and were mostly present at the superior position in dancers. Distribution of labral lesions between the dancers and the control group showed substantially more pronounced labral lesions at the superior, posterosuperior, and anterosuperior positions in dancers (54 lesions in 28 dancer's hips vs 10 lesions in 8 control hips). Herniation pits were found significantly more often (p = 0.002) in dancer's hips (n = 31, 52.5%), 25 of them being located in a superior position. A cam-type morphology was found for one dancer and a retroverted hip was noted for one control. Femoroacetabular subluxations were observed in the splits position (mean: 2.05 mm). The prevalence of typical FAI of the cam or pincer type was low in this selected population of professional ballet

  20. The 'bridging sign', a MR finding for combined full-thickness tears of the subscapularis tendon and the supraspinatus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Young [Dept. of Radiology, Saint Paul' s Hospital, The Catholic Univ. of Korea, Seoul (Korea, Republic of); Yoon, Young Cheol; Cha, Dong Ik [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ, School of Medicine, Seoul (Korea, Republic of)], e-mail: ycyoon@skku.edu; Yoo, Jae-Chul [Dept. of Orthopedic Surgery, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of); Jung, Jee Young [Dept. of Radiology, School of Medicine, Chung-Ang Univ., Seoul (Korea, Republic of)

    2013-02-15

    Background: In daily practice, we discovered one of the secondary magnetic resonance (MR) findings of the subscapularis (SSC) tendon tear, the 'bridging sign', which has not been previously described. Purpose: To describe the 'bridging sign' on shoulder MR imaging and its radiological and clinical significance in patients with SSC tendon tear. Material and Methods: Twenty-nine patients who had undergone shoulder arthroscopy and had full-thickness tear of the subscapularis tendon were enrolled. The medical records of the 29 patients were retrospectively reviewed for the duration of shoulder pain, rotator cuff tears, and associated arthroscopic findings: biceps tendon abnormality and superior glenoid labral tear. Then, preoperative shoulder MR images were retrospectively reviewed for the presence or absence of the 'bridging sign' and associated MR findings: periarticular fluid and fatty atrophy of the supraspinatus and subscapularis muscles. The type of rotator cuff tear associated with the 'bridging sign' was assessed and the sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of a certain type of rotator cuff tear were calculated. Associated arthroscopic and MR findings and mean duration of the shoulder pain between the patients with and without the 'bridging sign' were compared. Results: The 'bridging sign' was seen in 17 of 29 patients and corresponded to a complex of the torn and superomedially retracted subscapularis tendon, coracohumeral ligament, and superior glenohumeral ligament, adhered to the anterior margin of the torn supraspinatus (SSP) tendon on arthroscopy. All patients with the 'bridging sign' had combined full-thickness tear (FTT) of the cranial 1/2 portion of the subscapularis tendon and anterior 1/2 portion of the SSP tendon. The sensitivity, specificity, and accuracy of the 'bridging sign' for the diagnosis of combined FTTs of

  1. Comparison between conventional MR arthrograhphy and abduction and external rotation MR arthrography in revealing tears of the antero-inferior glenoid labrum

    International Nuclear Information System (INIS)

    Choi, Jung Ah; Suh, Sang Il; Kim, Baek Hyun; Cha, Sang Hoon; Kim, Myung Gyu; Lee, Ki Yeol; Lee, Chang Hee

    2001-01-01

    To compare, in terms of their demonstration of tears of the anterior glenoid labrum, oblique axial MR arthrography obtained with the patient's shoulder in the abduction and external rotation (ABER) position, with conventional axial MR arthrography obtained with the patient's arm in the neutral position. MR arthrography of the shoulder, including additional oblique axial sequences with the patient in the ABER position, was performed in 30 patients with a clinical history of recurrent anterior shoulder dislocation. The degree of anterior glenoid labral tear or defect was evaluated in both the conventional axial and the ABER position by two radiologists. Decisions were reached by consensus, and a three-point scale was used: grade 1=normal; grade 2=probable tear, diagnosed when subtle increased signal intensity in the labrum was apparent; grade 3=definite tear/defect, when a contrast material-filled gap between the labrum and the glenoid rim or deficient labrum was present. The scores for each imaging sequence were averaged and to compare conventional axial and ABER position scans, Student's t test was performed. In 21 (70%) of 30 patients, the same degree of anterior instability was revealed by both imaging sequences. Eight (27%) had a lower grade in the axial position than in the ABER position, while one (3%) had a higher grade in the axial position. Three whose axial scan was grade 1 showed only equivocal evidence of tearing, but their ABER-position scan, in which a contrast material-filled gap between the labrum and the glenoid rim was present, was grade 3. The average grade was 2.5 (SD=0.73) for axial scans and 2.8 (SD=0.46) for the ABER position. The difference between axial and ABER-position scans was statistically significant (p<0.05). MR arthrography with the patient's shoulder in the ABER position is more efficient than conventional axial scanning in revealing the degree of tear or defect of the anterior glenoid labrum. When equivocal features are seen at

  2. Acetabular roof stress fracture: a rare cause of hip pain in children ...

    African Journals Online (AJOL)

    Stress fracture of acetabular roof is an unusual cause of hip pain. It is considered as an underdiagnosed entity. People who are more susceptible to experience this fracture are athletes, soldiers and dancers. We present the case of an 11 year old girl with a roof acetabular stress fracture for which the diagnosis and ...

  3. Cement-in-cement acetabular revision with a constrained tripolar component.

    Science.gov (United States)

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  4. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Christophe Boulay

    2014-01-01

    Full Text Available Acetabular cup orientation (inclination and anteversion is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter could determine the safe range of pelvis tilt (positional parameter for an individual and not a group.

  5. As tears go by : Baby tears trigger more brain activity than adult tears in nulliparous women

    NARCIS (Netherlands)

    Hendricx-Riem, M.M.E.; De Carli, P.; van IJzendoorn, M.H.; Vingerhoets, A.J.J.M.; Bakermans-Kranenburg, M.J.

    2017-01-01

    The current functional magnetic resonance imaging study examines brain activity during the perception of infant and adult tears. Infant tears evoke stronger responses in the visual cortex than adult tears, indicating that infant tears are highly salient. In addition, our study shows that infant

  6. Paralabral cysts in the hip joint: findings at MR arthrography

    International Nuclear Information System (INIS)

    Magerkurth, Olaf; Jacobson, Jon A.; Girish, Gandikota; Kalume Brigido, Monica; Fessell, David; Bedi, Asheesh

    2012-01-01

    The purpose of this research was to retrospectively characterize paralabral cysts of the hip as seen at MR arthrography. After Institutional Review Board approval, 704 patients who had MR arthrography were identified over a 3-year period and 40 patients were identified as having a cyst or fluid collection at the hip by MR report. MR images from these 40 patients were retrospectively reviewed by three radiologists where 18 were found to have a paralabral cyst, which were characterized as follows: location, configuration, contrast filling, size of the cyst, extent, direction, and whether associated osseous changes were present. In addition, the acetabular labrum was assessed for tears and, if present, the location and pattern were characterized. Paralabral cysts were located anterosuperiorly in 56%, anteriorly in 22%, posterosuperiorly in 17%, and anteroinferiorly in 6% of cases. The vast majority (94%) were multilocular and filled with intra-articular contrast medium. The average dimensions were 8 x 7 x 11 mm. The paralabral cyst demonstrated extracapsular extension in 72% of cases, with 39% located between the ilium and gluteus minimus, and 22% between the ilium and iliopsoas. Remodeling of the ilium adjacent to the cyst was observed in 50% of these cases. A labral tear was at the base of the labrum adjacent to the cyst in 78% of cases, while the tear was isolated to the body of the labrum in 22%. Tears were most commonly anterosuperior (55%) or anterior (28%) in location. Our results show that paralabral cysts of the hip are most commonly located anterosuperiorly, are multilocular, fill with intra-articular contrast medium, have average dimensions up to 11 mm, and often extend extracapsularly between muscle and bone where they may remodel the adjacent ilium. (orig.)

  7. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects.

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. IV.

  8. Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR.

    Science.gov (United States)

    Park, H J; Lee, S Y; Kim, M S; Choi, S H; Chung, E C; Kook, S H; Kim, E

    2015-03-01

    To evaluate the diagnostic accuracy of three-dimensional (3D) enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) shoulder MR for the detection of rotator cuff tears, labral lesions and calcific tendonitis of the rotator cuff in comparison with two-dimensional (2D) fast spin echo T2 fat saturation (FS) MR. This retrospective study included 73 patients who underwent shoulder MRI using the eTHRIVE technique. Shoulder MR images were interpreted separately by two radiologists. They evaluated anatomic identification and image quality of the shoulder joint on routine MRI sequences (axial and oblique coronal T2 FS images) and compared them with the reformatted eTHRIVE images. The images were scored on a four-point scale (0, poor; 1, questionable; 2, adequate; 3, excellent) according to the degree of homogeneous and sufficient fat saturation to penetrate bone and soft tissue, visualization of the glenoid labrum and distinction of the supraspinatus tendon (SST). The diagnostic accuracy of eTHRIVE images compared with routine MRI sequences was evaluated in the setting of rotator cuff tears, glenoid labral injuries and calcific tendonitis of the SST. Fat saturation scores for eTHRIVE were significantly higher than those of the T2 FS for both radiologists. The sensitivity and accuracy of the T2 FS in diagnosing rotor cuff tears were >90%, whereas sensitivity and accuracy of the eTHRIVE method were significantly lower. The sensitivity, specificity and accuracy of both images in diagnosing labral injuries and calcific tendonitis were similar and showed no significant differences. The specificity of both images for the diagnosis of labral injuries and calcific tendonitis was higher than the sensitivities. The accuracy of 3D eTHRIVE imaging was comparable to that of 2D FSE T2 FS for the diagnosis of glenoid labral injury and calcific tendonitis of SST. The 3D eTHRIVE technique was superior to 2D FSE T2 FS in terms of fat saturation. Overall, 3D eTHRIVE was inferior

  9. Variability and Comprehensiveness of North American Online Available Physical Therapy Protocols Following Hip Arthroscopy for Femoroacetabular Impingement and Labral Repair.

    Science.gov (United States)

    Cvetanovich, Gregory L; Lizzio, Vincent; Meta, Fabien; Chan, Derek; Zaltz, Ira; Nho, Shane J; Makhni, Eric C

    2017-11-01

    To assess comprehensiveness and variability of postoperative physical therapy protocols published online following hip arthroscopy for femoroacetabular impingement (FAI) and/or labral repair. Surgeons were identified by the International Society for Hip Arthroscopy "Find a Surgeon" feature in North America (http://www.isha.net/members/, search August 10, 2016). Exclusion criteria included nonsurgeons and protocols for conditions other than hip arthroscopy for FAI and/or labral tear. Protocols were identified by review of surgeons' personal and departmental websites and evaluated for postoperative restrictions, rehabilitation components, and the time points for ending restrictions and initiating activities. Of 111 surgeons available online, 31 (27.9%) had postoperative hip arthroscopy physical therapy protocols available online. Bracing was used in 54.8% (17/31) of protocols for median 2-week duration (range, 1-6 weeks). Most protocols specified the initial postoperative weight-bearing status (29/31, 93.5%), most frequently partial weight-bearing with 20 pounds foot flat (20/29, 69.0%). The duration of weight-bearing restriction was median 3 weeks (range, 2-6) for FAI and median 6 weeks (range, 3-8) for microfracture. The majority of protocols specified initial range of motion limitations (26/31, 83.9%) for median 3 weeks (range, 1.5-12). There was substantial variation in the rehabilitation activities and time points for initiating activities. Time to return to running was specified by 20/31 (64.5%) protocols at median 12 weeks (range, 6-19), and return to sport timing was specified by 13/31 (41.9%) protocols at median 15.5 weeks (range, 9-23). There is considerable variability in postoperative physical therapy protocols available online following hip arthroscopy for FAI, including postoperative restrictions, rehabilitation activities, and time points for activities. This information offers residents, fellows, and established hip arthroscopists a centralized

  10. [Effects of Surgically Treated Pelvic Ring and Acetabular Fractures on Postural Control].

    Science.gov (United States)

    Lang, P; Schnegelberger, A; Riesner, H-J; Stuby, F; Friemert, B; Palm, H-G

    2016-04-01

    The aim of surgical treatment of pelvic ring and acetabular fractures is to allow rapid mobilisation of patients in order to restore stance and gait stability (postural control), as this significantly correlates with a positive outcome. The regulation of postural stability is mainly controlled by transmission of proprioceptive stimuli. In addition, the pelvis serves as a connection between the legs and the spine and thus is also of great importance for mechanical stabilisation. It remains unclear whether surgical treatment of pelvic ring and acetabular fractures affects the regulation of postural control. Therefore, the aim of this study was to examine the impact of surgically treated pelvic ring and acetabular fractures on postural stability by means of computerised dynamic posturography (CDP) after a mean of 35 months and to compare the results with a healthy control group. A retrospective case control study of 38 patients with surgically treated pelvic ring and acetabular fractures and 38 healthy volunteers was carried out using CDP. The average time of follow-up was 35 (12-78) months. The most important outcome parameter in this investigation was the overall stability index (OSI). Hip joint mobility, the health-related quality of life (SF-12) and pain were supplementary outcome parameters. It was found that surgically treated pelvic ring and acetabular fractures had no influence on postural stability. The OSI was 2.1 ° in the patient group and 1.9 ° in the control group. There was no significant difference between the groups in hip joint mobility. A total of 52 % of patients showed no or only mild pain. Mean health-related quality of life was the same as in the total population. Surgically treated pelvic ring and acetabular fractures do not lead to deterioration in postural control in the mid term. This is of high prognostic importance for rapid mobilisation of the patients. Therefore no increase in the risk of falling is expected after successfully

  11. Measurement of acetabular morphology under three-dimensional reconstruction of CT and significance

    International Nuclear Information System (INIS)

    Han Yingying; Yang Qiwei; Lai Ying; Hao Shuang; Ma Hecheng; Xiao Chengshuang; Li Youqiong

    2011-01-01

    Objective: To measure the acetabular morphology of Chinese on CT three-dimensional (3D) reconstruction image, and provide the evidence on the prevention and treatment of hip disease. Methods: 96 cases (192 sides) of adult hip CT scans were reconstructed, the acetabular index (AA), center-edge (CE), ACE angle, anteversion angle (AVA), abduction angle (ABA), and vertical diameter (SID) were measured. Results: The total acetabular index was (8.78±5.34)°, of which male was (7.84±5.55)° and female was (9.60±5.06)°. The total CE was (33.59±5.91)°, of which male was (34.55±6.03)° and female was (32.78±5.70)°. The total ACE angle was (29.01±5.65)°, of which male was (28.02±5.94)° and female was (29.80±5.30)°. The total AVA was (20.92±5.55)°, of which male was (20.48±5.08)° and female was (21.25±5.89)°. The total ABA was (51.27±4.16)°, of which male was (51.71±4.37)° and female was (50.89±3.96)°. The total SID was (53.79±3.92) mm, of which male was (56.55±2.64) mm and female was (51.46±3.25) mm. Of the above data, there were statistical differences in the acetabular index, CE angle, ACE angle and acetabular diameter between men and women (P<0.05), Chinese and foreigners (P<0.05). While there was no statistical difference between the left and right sides (P>0.05). Conclusion: There are differences in acetabular morphology between men and women, Chinese and foreigners. Compared with simply using overseas data, it is better to study morphological parameters of native acetabula to instruct the preoperative preparation and operation of national total hip arthroplasty surgery. And it is meaningful to design national parameters. (authors)

  12. 3D double-echo steady-state sequence assessment of hip joint cartilage and labrum at 3 Tesla: comparative analysis of magnetic resonance imaging and intraoperative data

    Energy Technology Data Exchange (ETDEWEB)

    Schleich, Christoph; Antoch, Gerald [University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Medical Faculty, Duesseldorf (Germany); Hesper, Tobias; Rettegi, Fanni; Zilkens, Christoph; Krauspe, Ruediger; Bittersohl, Bernd [University of Dusseldorf, Department of Orthopedic Surgery, Medical Faculty, Duesseldorf (Germany); Hosalkar, Harish S. [Paradise Valley Hospital, Joint Preservation and Deformity Correction, San Diego, CA (United States); Tri-city Medical Center, Hip Preservation, San Diego, CA (United States)

    2017-10-15

    To assess the diagnostic accuracy of a high-resolution, three-dimensional (3D) double-echo steady-state (DESS) sequence with radial imaging at 3 Tesla (T) for evaluating cartilage and labral alterations in the hip. Magnetic resonance imaging (MRI) data obtained at 3 T, including radially reformatted DESS images and intraoperative data of 45 patients (mean age 42 ± 13.7 years) who underwent hip arthroscopy, were compared. The acetabular cartilage and labrum of the upper hemisphere of the acetabulum and the central femoral head cartilage were evaluated. Sensitivity, specificity, accuracy, and negative and positive predictive values were determined. Sensitivity, specificity and accuracy of the DESS technique were 96.7%, 75% and 93.7% for detecting cartilage lesions and 98%, 76.2% and 95.9% for detecting labral lesions. The positive and negative predictive values for detecting or ruling out cartilage lesions were 96% and 78.9%. For labral lesions, the positive and negative predictive values were 97.5% and 80%. A high-resolution, 3D DESS technique with radial imaging at 3 T demonstrated high accuracy for detecting hip cartilage and labral lesions with excellent interobserver agreement and moderate correlation between MRI and intraoperative assessment. (orig.)

  13. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Summary Background Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Materials and methods Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. Results FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. Conclusion FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. Level of evidence IV. PMID:29264339

  14. Digestive Fistula Due to Acetabular Protrusion: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Carlos Marqués

    2017-12-01

    Full Text Available Intrapelvic migration of the acetabular component after primary or revision hip arthroplasty is a rare complication. We present a case of an intrapelvic migration of the acetabular component after a revision hip arthroplasty which led to an enteric fistula to the hip joint as well as to a sigmoid colon perforation.

  15. Surgical Site Infection Following Fixation of Acetabular Fractures.

    Science.gov (United States)

    Iqbal, Faizan; Younus, Sajid; Asmatullah; Zia, Osama Bin; Khan, Naveed

    2017-09-01

    Acetabular fractures are mainly caused by high energy trauma. Surgical fixation of these fractures requires extensive surgical exposure which increases the length of operation and blood loss as well. This may increase the risk of surgical site infection. Our aim is to evaluate the prevalence of surgical site infections and the risk factors associated with it so as to minimize its chances. A total of 261 patients who underwent acetabular fracture surgery were retrospectively reviewed. Patients were divided into 2 groups, with or without surgical site infection. Factors examined include patients' gender, age, body mass index (BMI), time between injury and surgery, operative time, estimated blood loss, number of packed red blood cell transfused, length of total intensive care unit (ICU) stay, fracture type, surgical approach, smoking status, patients' comorbids and associated injuries. Fourteen patients (5.4%) developed surgical site infection. Out of 14 infections, 4 were superficial and 10 were deep. The factors that were found to be associated with surgical site infection following acetabular fracture fixation were prolonged operation time, increased BMI, prolonged ICU stay, larger amount of packed red blood cell transfused and associated genitourinary and abdominal trauma. In our study, we conclude that measures should be undertaken to attenuate the chances of surgical site infection in this major surgery by considering the risk factors significantly associated with it.

  16. Anterior cruciate ligament tear: comparison of MR features between complete and partial tear

    International Nuclear Information System (INIS)

    Song, Ki Young; Lee, Joo Hyuk; Park, Jin Hee; Lee, Yu Jin; Rho, Eun Jin; Kim, Young Hoon; Yi, Jeong Geun; Ahn, Joong Mo

    1997-01-01

    To determine the MRI features which distinguish complete and partial tear of the anterior cruciate ligament(ACL) and to thus improve MRI interpretation. In 80 patients, we analyzed MR findings of direct and indirect signs of ACL tear (complete tear, 61 cases, partial tear, 19 cases) confirmed by arthroscopy or surgery, and compared the relative incidence of each sign in cases of complete and partial tear. Direct and indirect signs were found in 61 (100%) and 60 cases (98.4%), respectively, in complete tears, but in 16 (84.2%) and 15 cases (78.9%), respectively, in partial tears. Poor visualization, discontinuity and hyperintensity were seen in all complete tears but in only nine cases (47.4%) of partial tear. A wavy or abnormal contour was seen in 53 cases (86.9%) of complete tear and 14 (73.7%) of partial tear. A wavy contour without other direct signs was seen in only five cases (26.3%) of partial tear. Three cases (15.8%) of partial tear showed normal MR finding. Indirect signs, i.e. abnormal ACL angle, abnormal ACL-Blumensaat line angle, abnormal posterior cruciate ligament (PCL) line, abnormal PCL angle, PCL buckling, anterior displacement of tibia, posterior displacement of lateral meniscus, bone bruise, Segond fracture, tear of collateral ligaments, PCL, and tear of meniscus were commoner in complete than in partial tears. Two cases of O'Donoghue's triad and two of popliteus injury were seen only in complete tears. Direct and indirect signs of ACL tear were more commonly noted in complete than in partial tears. The latter showed MR features varying from normal to almost complete tear. We suggest that a wavy contour without other direct signs is indicative of a partial tear, and that O'Donoghue's triad and popliteus muscle injury are indirect signs of a complete tear

  17. Streaming tearing mode

    Science.gov (United States)

    Shigeta, M.; Sato, T.; Dasgupta, B.

    1985-01-01

    The magnetohydrodynamic stability of streaming tearing mode is investigated numerically. A bulk plasma flow parallel to the antiparallel magnetic field lines and localized in the neutral sheet excites a streaming tearing mode more strongly than the usual tearing mode, particularly for the wavelength of the order of the neutral sheet width (or smaller), which is stable for the usual tearing mode. Interestingly, examination of the eigenfunctions of the velocity perturbation and the magnetic field perturbation indicates that the streaming tearing mode carries more energy in terms of the kinetic energy rather than the magnetic energy. This suggests that the streaming tearing mode instability can be a more feasible mechanism of plasma acceleration than the usual tearing mode instability.

  18. Imaging of sports-related hip and groin injuries.

    Science.gov (United States)

    Lischuk, Andrew W; Dorantes, Thomas M; Wong, William; Haims, Andrew H

    2010-05-01

    A normally functioning hip joint is imperative for athletes who use their lower extremities with running, jumping, or kicking activities. Sports-related injuries of the hip and groin are far less frequent than injuries to the more distal aspect of the extremity, accounting for less than 10% of lower extremity injuries. Despite the lower incidence, hip and groin injuries can lead to significant clinical and diagnostic challenges related to the complex anatomy and biomechanical considerations of this region. Loads up to 8 times normal body weight have been documented in the joint in common daily activities, such as jogging, with significantly greater force expected during competitive athletics. Additionally, treatment for hip and groin injuries can obviate the participation of medical and surgical specialties, with a multidisciplinary approach frequently required. Delay in diagnosis and triage of these injuries may cause loss of time from competition and, potentially, early onset of degenerative changes. Magnetic resonance imaging (MRI) of the hip has proven to be the gold standard for the diagnosis of sports-related hip and groin injuries in the setting of negative radiographs. With its exquisite soft tissue contrast, multiplanar capabilities, and lack of ionizing radiation, MRI is unmatched in the noninvasive diagnosis of intra-articular and extra-articular pathology, as well as intraosseous processes. This review focuses on MRI of common athletic injuries of the hip and groin, including acetabular labral tears, femoral acetabular impingement syndrome, muscle injuries around the hip and groin (including athletic pubalgia), and athletic osseous injuries.

  19. Surgical Stabilization of Pelvic and Acetabular Fractures: A Review on the Determinants of Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    SS Sathappan

    2010-03-01

    Full Text Available AIM: Pelvic and acetabular fractures are associated with high-energy trauma. The aim of this study was to identify factors that are associated with specific clinical outcomes following treatment for these fractures. METHODS: A consecutive series of 30 patients who had surgical intervention for either pelvic or acetabular fractures formed the sample for this study. Clinical variables reviewed were: age, associated injuries, number of surgical procedures, time to surgery and post-operative complications. Clinical outcomes were assessed using Matta’s grading of post- operative fracture reduction alignment, and functional outcomes were graded using D'Aubigne & Postel’s Hip scoring system. RESULTS: Study subjects included twelve pelvic fractures and eighteen acetabular fractures. Patients older than 50 years of age had poorer hip scores despite surgery. Earlier fracture fixation (within five days was associated with better hip scores. Patients with acetabular fractures generally had better functional outcomes than patients with pelvic fractures (mean hip score 15.0 vs. 13.5. Closer anatomical reduction of acetabular fractures was associated with better functional outcome. CONCLUSION: Improved clinical outcomes are associated with younger age, fewer concomitant injuries, shorter time interval to surgery and more closely approximated anatomical fracture reduction.

  20. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    Science.gov (United States)

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  1. Assessment of trochanteric osteotomy fragment union after acetabular fracture surgery.

    Science.gov (United States)

    Dubina, Andrew G; Wickramaratne, Niluka; O'Toole, Robert V; Manson, Theodore T

    2017-02-01

    Trochanteric osteotomies are performed in conjunction with standard approaches to improve surgical exposure during open reduction and internal fixation (ORIF) of acetabular fractures. The literature on total hip arthroplasty reports nonunion rates as high as 30% associated with trochanteric osteotomies; however, few data exist regarding the outcomes of trochanteric osteotomies for acetabular fracture surgery. Our hypotheses were 1) patients receiving trochanteric osteotomies during ORIF of acetabular fractures have a low rate of nonunion of the osteotomy fragment, and 2) hip abduction precautions are not necessary with digastric type osteotomies. A retrospective review was conducted to identify patients with acetabular fractures between July 2002 and June 2010 (n=734 fractures) who required trochanteric osteotomies (n=64, 9% of fractures). Forty-seven met inclusion criteria of adequate follow-up (>56days). No excluded patient experienced a complication. Fractures were classified using the Letournel-Judet classification system. Only seven (20%) of 35 patients who received digastric osteotomies had hip abduction precautions applied during the postoperative period. All study patients were shown to have radiographic union at the trochanteric osteotomy site (100% union rate, n=47). Hip abduction precautions intended to protect the osteotomy site and reduce the risk of nonunion and fixation failure were infrequently applied to patients with digastric osteotomies (20%) in this cohort. Multiple protective factors against nonunion were present in this study population compared with previous arthroplasty studies from other institutions. Trochanteric osteotomies are not associated with a significant nonunion rate, and digastric osteotomies might be safely managed without hip abduction precautions. Copyright © 2016. Published by Elsevier Ltd.

  2. Cemented total hip replacement cable debris and acetabular construct durability.

    Science.gov (United States)

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  3. Radiological landmarks for the safe extra-capsular placement of supra-acetabular half pins for external fixation.

    Science.gov (United States)

    Lidder, Surjit; Heidari, Nima; Gänsslen, Axel; Grechenig, Wolfgang

    2013-03-01

    Low anterior external fixators are constructed by placing half pins in the dense bone tunnel of the supra-acetabular region in an anterior to posterior direction. Although the placement of these pins is extra-articular, they may still breach the hip capsule on the anterior inferior iliac spine and thus be intra-capsular. We aim to provide radiological markers for the most superior fibres of the capsule to allow safe extra-capsular pin placement within the supra-acetabular bone tunnel. Thirteen cadaveric pelves were used for this study. The supra-acetabular bone tunnel was visualised with an image intensifier. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images. Once all images were acquired they were calibrated and analysed to estimate the dimensions of the supra-acetabular bone tunnel and the reflection of the hip capsule. The median height of the bone tunnel was 23.6 mm (18.9-33.2) and maximum width was 11.4 mm (7.6-16.3). The inferior margin of the bone tunnel was 6.7 mm (1.1-14.5) superior to the acetabular dome, and the most proximal fibres of the capsule were 9.3 mm (4.7-6.1) superior to the acetabular dome. The inferior portion of the tunnel was 3.7 mm (0.3-8.9) within the joint. Half pins for the construction of a pelvic external fixator should be placed in the upper half of the supra-acetabular bone corridor to minimise the risk of intra-capsular placement.

  4. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  5. Minimum ten-year follow-up of acetabular fracture fixation from the Irish tertiary referral centre.

    LENUS (Irish Health Repository)

    Magill, Paul

    2012-04-01

    Successful outcome from acetabular fracture fixation is multi-factorial. Long-term results are not frequently reported. Pooling such data from high output centres will help progress acetabular fixation. This paper presents the first ten-year data from the Irish tertiary referral centre.

  6. Referral Patterns for Chronic Groin Pain and Athletic Pubalgia/Sports Hernia: Magnetic Resonance Imaging Findings, Treatment, and Outcomes.

    Science.gov (United States)

    Zoland, Mark P; Maeder, Matthew E; Iraci, Joseph C; Klein, Devon A

    Chronic groin pain is a common problem and has been well-described in high-performance athletes. Its presentation in the recreational athlete has been less frequently described. We present the experience of a tertiary group of physicians specializing in groin pain and athletic pubalgia. Dynamic magnetic resonance imaging (MRI) protocol was employed. Surgery was performed in patients failing non-surgical management. A retrospective review was performed. Of 117 mostly non-professional athletes, there were 79 MRI-positive cases of athletic pubalgia (68%). Other common findings were acetabular labral tear (57%) and inguinal hernia (35%). Employment of a dynamic MRI protocol increased sensitivity for certain pathologies. Of positive athletic pubalgia cases, 49% went on to have surgical repair. The satisfaction rate in the surgical group was 90% at follow up. Advances in MRI have increased our ability to characterize and diagnose specific injuries causing groin pain. We present our diagnostic algorithm, including an MRI protocol that not only evaluates the groin, but has increased sensitivity for additional findings such as inguinal hernia and abdominal wall deficiencies. A targeted work-up and subsequent surgical treatment in the appropriate patient, even in the recreational athletic population, has yielded a 90% satisfaction rate.

  7. A Special Tear Pattern of Anterior Horn of the Lateral Meniscus: Macerated Tear.

    Science.gov (United States)

    Zheng, Jiapeng; Zhai, Wenliang; Li, Qiang; Jia, Qianxin; Lin, Dasheng

    2017-01-01

    We describe a special, interesting phenomenon found in the anterior horn of the lateral meniscus (AHLM): most tear patterns in the AHLM are distinctive, with loose fibers in injured region and circumferential fiber bundles were separated. We name it as macerated tear. The goal of this study was to bring forward a new type of meniscal tear in the AHLM and investigate its clinical value. AHLM tears underwent arthroscopic surgery from January 2012 to December 2014 were included. Data regarding the integrity of AHLM were prospectively recorded in a data registry. Tear morphology and treatment received were subsequently extracted by 2 independent reviewers from operative notes and arthroscopic surgical photos. A total of 60 AHLM tears in 60 patients (mean age 27.1 years) were grouped into horizontal tears (n = 15, 25%), vertical tears (n = 14, 23%), complex tears (n = 6, 10%), and macerated tears (n = 25, 42%). There were 6 patients with AHLM cysts in macerated tear group and one patient in vertical tear group. 60 patients were performed arthroscopic meniscus repairs and were followed-up with averaged 18.7 months. Each group had significant postoperative improvement in Lysholm and IKDC scores (p 0.05). This study demonstrated that the macerated tear is common in the tear pattern of AHLM. However, feasibility of the treatment of this type of meniscal tear, especially the meniscus repairs still requires further study.

  8. Abduction and external rotation (ABER) MR arthrography of the shoulder. Benefits and limitations

    International Nuclear Information System (INIS)

    Mostafa, A.; Gokan, Takehiko; Munechika, Hirotsugu; Ogawa, Takashi; El-Feky, A.A.

    2001-01-01

    The purpose of this study was to show the benefits and limitations of using abduction and external rotation (ABER) positions of the arm during MR arthrography of the shoulder in the evaluation of the rotator-cuff tendon, the capsulolabral complex and the shoulder joint after surgery. Forty-seven patients complaining of either shoulder instability, chronic shoulder pain, pain of unknown cause or pain following shoulder surgery were studied using the direct MR arthrography technique in both the standard neutral position with the arm adducted as well as with the arm in the ABER position. A correlation was obtained between the MR arthrography findings and the surgical findings in 10 reports and clinical presentations of the examined patients. Three patients [6%] were unable to perform ABER positioning. ABER oblique axial images were better than standard oblique coronal images in revealing undersurface tears of the rotator cuff particularly of the grade I type. Four tears were missed in standard images. Oblique axial images were better than standard axial images in demonstrating non-displaced anterior labral tears. One tear was missed and two tears were suspected in the standard images. Oblique axial images were less sensitive than oblique coronal images in the diagnosis of superior labral tears. Two tears were missed in ABER images. The ABER oblique axial MR arthrogram is a useful adjunct to the standard axial and oblique coronal MR arthrograms for assessment of capsulolabral abnormalities and rotator-cuff tendon tears despite some limitations. (author)

  9. Acetabular labrum of hip joint in osteoarthritis: A qualitative original study and short review of the literature.

    Science.gov (United States)

    Kapetanakis, S; Dermon, A; Gkantsinikoudis, N; Kommata, V; Soukakos, P; Dermon, C R

    2017-01-01

    Histological architecture of normal acetabular labrum regarding free nerve endings (FNEs) and mechanoreceptors (MRs) has been satisfactorily described in the literature. However, the presence of FNEs and MRs in acetabular labrum of hip joint has been analyzed only once in patients with osteoarthritis (OA). Aim of this article is to report histological distribution pattern of FNEs and MRs in acetabular labrum of patients with severe OA, at the same time conducting a comparison with normal acetabular labrum described in the literature. Seven patients with severe hip OA were enrolled in this study. Patient selection was assisted by the utilization of specific clinical scales delineated by the American College of Rheumatology. After successful total hip arthroplasty, tissue samples of acetabular labra of seven patients were histologically processed and stained with the gold standard chloride method, which was subsequently examined under a compound microscope. FNEs and MRs constituted the major histological structures. Identified MRs included Pacini corpuscles, Ruffini corpuscles, and Golgi-Mazzoni corpuscles. The presence of FNEs was predominant in the middle part of the acetabular labrum, featuring a remarkable decrease in peripheral parts. In contrast, MRs were detected basically in peripheral parts and less in the middle part. Differentiation of the distribution pattern of MRs and FNEs in acetabular labrum of hip joint is remarkable between normal patients and patients with severe OA. The abundance of FNEs in the middle part of the pathologic labrum is mainly responsible for the observed discrimination. A "conversion" of MRs to FNEs may occur during OA progression, modulating therefore this pattern as well as the upcoming clinical manifestations.

  10. Three-dimensional MRI of the glenoid labrum

    International Nuclear Information System (INIS)

    Loehr, S.P.; Pope, T.L. Jr.; Martin, D.F.; Link, K.M.; Monu, J.U.V.; Hunter, M.; Reboussin, D.

    1995-01-01

    The objective of this study was to assess the accuracy of three-dimensional (3D) magnetic resonance imaging (MRI) reformation in the evaluation of tears of the glenoid labrum complex (GLC). Fifty-five shoulders were evaluated by MRI using standard spin-echo sequences. Gradient-refocused-echo axial projections were used to assess the GLC on the two-dimensional (2D) studies. Three-dimensional Fourier transform multiplanar gradient-recalled imaging with a resolution of 0.7 mm was also performed in all patients. Independent analyses of the anterior and posterior labra were performed in a blinded manner for both the 2D and 3D studies by three experienced musculoskeletal radiologists. Observations of the imaging studies were compared with the videoarthroscopic findings. The appearance of the GLC was rated on a scale of 0 to 4 (0-2=normal, 3, 4=abnormal or torn). The diagnostic confidence was averaged from the three reader's scores. Anterior labral tears were effectively detected with sensitivities of 89% and 96% and specificities of 96% and 100% (P<0.0001) for the 2D and 3D studies, respectively. For posterior labral tears, the sensitivity and specificity of the 2D method were 47% and 98%, respectively. The sensitivity and specificity of the 3D volume sequence were 53% and 98%, respectively. The lower sensitivity of both imaging methods for detecting posterior labral tears may be influenced by the smaller number (n=5) of arthroscopically confirmed cases in our study and reflects the difficulty of visualizing the posteroinferior borders of the GLC with present MRI techniques. (orig.)

  11. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    Science.gov (United States)

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  12. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Fischer, U.; Vosshenrich, R.

    1993-01-01

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.) [de

  13. Rehabilitation following hip arthroscopy - A systematic review

    Directory of Open Access Journals (Sweden)

    Jeffrey S Grzybowski

    2015-05-01

    Full Text Available CONTEXT: Rehabilitation following hip arthroscopy is an integral component of the clinical outcome of the procedure. Given the increase in quantity, complexity, and diversity of procedures performed, a need exists to define the role of rehabilitation following hip arthroscopy.OBJECTIVES: 1 To determine the current rehabilitation protocols utilized following hip arthroscopy in the current literature, 2 to determine if clinical outcomes are significantly different based on different post-operative rehabilitation protocols; and 3 to propose the best-available evidence-based rehabilitation program following hip arthroscopy.DATA SOURCES: Per PRISMA guidelines and checklist, Medline, SciVerse Scopus, SportDiscus, and Cochrane Central Register of Controlled Trials were searched.STUDY SELECTION: Level I-IV evidence clinical studies with minimum two-year follow-up reporting outcomes of hip arthroscopy with post-operative rehabilitation protocols described were included. DATA EXTRACTION: All study, subject, and surgery parameters were collected. All elements of rehabilitation were extracted and analyzed. Descriptive statistics were calculated. Study methodological quality was analyzed using the Modified Coleman Methodology Score (MCMS.RESULTS: 18 studies were included (2,092 subjects; 52% male, mean age 35.1 +/- 10.6 years, mean follow-up 3.2 +/- 1.0 years. Labral tear and femoroacetabular impingement were the most common diagnoses treated and labral debridement and femoral/acetabular osteochondroplasty the most common surgical techniques performed. Rehabilitation protocol parameters (weight-bearing, motion, strengthening, and return-to-sport were poorly reported. Differences in clinical outcomes were unable to be assessed given heterogeneity in study reporting. Time-, phase-, goal-, and precaution-based guidelines were extracted and reported.CONCLUSIONS: The current literature of hip arthroscopy rehabilitation lacks high-quality evidence to support a

  14. Deltoid muscle and tendon tears in patients with chronic rotator cuff tears

    International Nuclear Information System (INIS)

    Ilaslan, Hakan; Recht, Michael P.; Iannotti, Joseph P.

    2007-01-01

    To describe the magnetic resonance imaging (MRI) appearances of tears of the deltoid muscle and tendon in patients with rotator cuff tears and without a prior history of shoulder surgery. Deltoid tears diagnosed on MR examinations were prospectively recorded between February 2003 through June 2004. The images of these patients were then retrospectively reviewed to determine the location of the deltoid tear, the presence of rotator cuff tears, tendon retraction, muscle atrophy, degree of humeral head subluxation, bony erosive changes involving the undersurface of the acromion, and the presence of edema or fluid-like signal intensity in the deltoid muscle and overlying subcutaneous tissues. There were 24 (0.3%) patients with deltoid tears; nine men and 15 women. The age range was 54 to 87 (average 73) years. The right side was involved in 20 cases, and the left in four cases. Fifteen patients had full thickness and nine had partial thickness tears of the deltoid. Shoulder pain was the most common presenting symptom. The physical examination revealed a defect in the region of the deltoid in two patients. Nineteen patients had tears in the muscle belly near the musculotendinous junction, and five had avulsion of the tendon from the acromial origin. Full thickness rotator cuff tears were present in all of the patients, and 22 patients had associated muscle atrophy. Subcutaneous edema and fluid-like signal was present in 15 patients. Tears of the deltoid muscle or tendon is an unusual finding, but they can be seen in patients with chronic massive rotator cuff tears. Partial thickness tears tend to involve the undersurface of the deltoid muscle and tendon. Associated findings such as intramuscular cyst or ganglion in the deltoid muscle belly and subcutaneous edema or fluid-like signal overlying the deltoid in a patient with a rotator cuff tear should raise the suspicion of a deltoid tear. (orig.)

  15. Deltoid muscle and tendon tears in patients with chronic rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Ilaslan, Hakan; Recht, Michael P. [Cleveland Clinic, Musculoskeletal Radiology/A21, Division of Radiology, Cleveland, OH (United States); Iannotti, Joseph P. [Cleveland Clinic, Department of Orthopedic Surgery, Cleveland, OH (United States)

    2007-06-15

    To describe the magnetic resonance imaging (MRI) appearances of tears of the deltoid muscle and tendon in patients with rotator cuff tears and without a prior history of shoulder surgery. Deltoid tears diagnosed on MR examinations were prospectively recorded between February 2003 through June 2004. The images of these patients were then retrospectively reviewed to determine the location of the deltoid tear, the presence of rotator cuff tears, tendon retraction, muscle atrophy, degree of humeral head subluxation, bony erosive changes involving the undersurface of the acromion, and the presence of edema or fluid-like signal intensity in the deltoid muscle and overlying subcutaneous tissues. There were 24 (0.3%) patients with deltoid tears; nine men and 15 women. The age range was 54 to 87 (average 73) years. The right side was involved in 20 cases, and the left in four cases. Fifteen patients had full thickness and nine had partial thickness tears of the deltoid. Shoulder pain was the most common presenting symptom. The physical examination revealed a defect in the region of the deltoid in two patients. Nineteen patients had tears in the muscle belly near the musculotendinous junction, and five had avulsion of the tendon from the acromial origin. Full thickness rotator cuff tears were present in all of the patients, and 22 patients had associated muscle atrophy. Subcutaneous edema and fluid-like signal was present in 15 patients. Tears of the deltoid muscle or tendon is an unusual finding, but they can be seen in patients with chronic massive rotator cuff tears. Partial thickness tears tend to involve the undersurface of the deltoid muscle and tendon. Associated findings such as intramuscular cyst or ganglion in the deltoid muscle belly and subcutaneous edema or fluid-like signal overlying the deltoid in a patient with a rotator cuff tear should raise the suspicion of a deltoid tear. (orig.)

  16. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  17. Tear secretion and tear stability of women on hormonal contraceptives

    Directory of Open Access Journals (Sweden)

    Faustina Kemdinum Idu

    2013-01-01

    Conclusions: Injectable hormonal contraceptives had no significant effects on tear secretion and tear stability of healthy women of childbearing age. Further studies may be required to determine the effects of hormonal contraceptives on tear volume and stability of women with dry eyes.

  18. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    Science.gov (United States)

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  19. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    Science.gov (United States)

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Posterior trochanteric osteotomy in acetabular fractures for 32 cases.

    Science.gov (United States)

    Niu, Yunfei; An, Xiaofei; Xu, Shuogui; Wu, Dajiang; Zhang, Chuncai; Li, Ming

    2014-11-01

    The aim of this study is to explore the method and clinical outcome of posterior trochanteric osteotomy in acetabular fractures. From January 2000 to January 2008, 32 cases of acetabular fractures involving the dome of acetabulum underwent posterior trochanteric osteotomy for a better exposure and internal fixation with acetabular tridimensional memory fixation system. 28 cases (16 men and 12 women, mean age 39.9 years, range 16-73 years) were followed up with an average of 48.9 months (range of 19-95 months) and four were lost during follow up. Of 28 cases, 19 were fresh fractures and 9 were old fractures. The reduction was evaluated with Matta criteria. Clinical evaluation was based on modified Merle d'Aubigne and Postel scoring. Motor strength of the abductors was evaluated according to the Medical Research Council grading system. Ectopic ossification was classified according to Brooker criteria. Anatomical reduction was achieved in 17 cases and satisfied reduction in 10 patients. Poor reduction happened in an old fracture. All acetabular fractures got a direct bone union and no displacement and deep infection occurred. All osteotomies healed within 3.5 months without any nonunion, proximal migration of the greater trochanter, loosing or broken of instrumentation, and deep infection. Two superficial infections were healed with a regular dressing. Two patients underwent removal of implants from greater trochanter because of irritation. The strength of the abductors was of Grade 3/5 in two patients, Grade 4/5 in five patients, and normal in the rest. Clinical scoring was excellent to good in 84 %. Ectopic ossification occurred in five patients, grade 1 in two patients, grade 2 in two, and grade 3 in one. But function of hip joint was not seriously affected. Posterior trochanteric osteotomy can provide an adequate exposure of the dome of acetabulum without the associated complications like nonunion, proximal replacement, and weak of the abductors which often occur

  1. Does Increased Coefficient of Friction of Highly Porous Metal Increase Initial Stability at the Acetabular Interface?

    Science.gov (United States)

    Goldman, Ashton H; Armstrong, Lucas C; Owen, John R; Wayne, Jennifer S; Jiranek, William A

    2016-03-01

    Highly porous metal acetabular components illustrate a decreased rate of aseptic loosening in short-term follow-up compared with previous registry data. This study compared the effect of component surface roughness at the bone-implant interface and the quality of the bone on initial pressfit stability. The null hypothesis is that a standard porous coated acetabular cup would show no difference in initial stability as compared with a highly porous acetabular cup when subjected to a bending moment. Second, would bone mineral density (BMD) be a significant variable under these test conditions. In a cadaveric model, acetabular cup micromotion was measured during a 1-time cantilever bending moment applied to 2 generations of pressfit acetabular components. BMD data were also obtained from the femoral necks available for associated specimen. The mean bending moment at 150 μm was not found to be significantly different for Gription (24.6 ± 14.0 N m) cups vs Porocoat (25 ± 10.2 N m; P > .84). The peak bending moment tolerated by Gription cups (33.9 ± 20.3 N m) was not found to be significantly different from Porocoat (33.5 ± 12.2 N m; P > .92). No correlation between BMD and bending moment at 150 μm of displacement could be identified. The coefficient of friction provided by highly porous metal acetabular shells used in this study did not provide better resistance to migration under bending load when compared with a standard porous coated component. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A comparison of basal and eye-flush tears for the analysis of cat tear proteins.

    Science.gov (United States)

    Petznick, Andrea; Evans, Margaret D M; Madigan, Michele C; Markoulli, Maria; Garrett, Qian; Sweeney, Deborah F

    2011-02-01

    To identify a rapid and effective tear collection method providing sufficient tear volume and total protein content (TPC) for analysis of individual proteins in cats. Domestic adult short-haired cats (12-37 months; 2.7-6.6 kg) were used in the study. Basal tears without stimulation and eye-flush tears after instillation of saline (10 μl) were collected using microcapillary tubes from animal eyes either unwounded control or wounded with 9-mm central epithelial debridement giving four groups with n = 3. Tear comparisons were based on total time and rate for tear collection, TPC using micro bicinchoninic acid (BCA), tear immunoglobulin A (IgA), total matrix-metalloproteinase (MMP)-9 concentration using sandwich enzyme-linked immunosorbent assay (ELISA) and MMP-9 activity. Eye-flush tears were collected significantly faster than basal tears in wounded eyes with higher rates for tear collection in unwounded control and wounded eyes. TPC was significantly lower in eye-flush tears compared to basal tears. The relative proportion of tear IgA normalized to TPC (% IgA of TPC) was not significantly different between basal and eye-flush tears. In unwounded control eyes, MMP-9 was slightly higher in eye-flush than in basal tears; activity of MMP-9 in both tear types was similar. In wounded eyes, eye-flush tears showed highest MMP-9 levels and activity on Day 1, which subsequently decreased to Day 7. MMP-9 activity in basal tears from wounded eyes did not display changes in expression. Eye-flush tears can be collected rapidly providing sufficient tear volume and TPC. This study also indicates that eye-flush tears may be more suitable than basal tears for the analysis of MMPs following corneal wounding. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  3. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    Energy Technology Data Exchange (ETDEWEB)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B. [Duke University Medical Center, Department of Radiology, Durham, NC (United States)

    2011-02-15

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  4. Magnetic resonance arthrography of the shoulder: accuracy of gadolinium versus saline for rotator cuff and labral pathology

    International Nuclear Information System (INIS)

    Helms, Clyde A.; McGonegle, Shane J.; Vinson, Emily N.; Whiteside, Michael B.

    2011-01-01

    The purpose of this study was to evaluate the necessity of intra-articular gadolinium versus saline alone in magnetic resonance arthrography (MRA) of the shoulder. Our database was reviewed for 100 consecutive shoulder MRA examinations performed between January 2007 and December 2007. Patient information was blinded and images were retrospectively reviewed by at least two radiologists with dedicated musculoskeletal training. T2-weighted (T2W) images were initially analyzed in isolation to simulate MRA with saline alone. After a delay, the full study was analyzed including T1-weighted (T1W) and T2W images. If there was a significant discordance between the two analyses with regard to rotator cuff or labral pathology, the study was again reviewed by all evaluators in consensus to determine if the T1W images offered additional diagnostic information and increased diagnostic confidence. Of the 100 MRA examinations, there were 15 discordant cases. Two cases were discordant with regard to rotator cuff pathology and 13 were discordant on the basis of labral pathology. When the discordant cases were reviewed in consensus, the T2W images appeared to display rotator cuff and labral pathology as definitively as the T1W images. Interobserver and intraobserver variability was favored to have played a role in causing the discordances. MRA of the shoulder performed with joint distention provided by saline alone appears to offer equivalent diagnostic information to MRA performed with gadolinium enhancement. This protocol modification improves efficiency by eliminating several image series and provides a small cost savings by eliminating gadolinium. (orig.)

  5. Blocked Tear Duct

    Science.gov (United States)

    ... of the nose (lacrimal sac). From there tears travel down a duct (the nasolacrimal duct) draining into your nose. Once in the nose, tears are reabsorbed. A blockage can occur at any point in the tear drainage system, from the puncta ...

  6. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  7. Increased Mortality in Elderly Patients with Sarcopenia and Acetabular Fractures.

    Science.gov (United States)

    Deren, Matthew E; Babu, Jacob; Cohen, Eric M; Machan, Jason; Born, Christopher T; Hayda, Roman

    2017-02-01

    Sarcopenia is a condition of clinically relevant loss of muscle mass and function. Acetabular fractures in elderly patients are common and difficult to treat. This study aimed to determine if sarcopenia is common in elderly patients with acetabular fractures and correlates with lower-energy mechanisms of injury, higher rates of complications, and higher mortality than patients with normal muscle mass. The Rhode Island Hospital Trauma Database was queried for patients who were ≥60 years of age from 2005 to 2014 using the International Classification of Diseases, Ninth Revision, code for closed acetabular fracture, 808.0. Charts were retrospectively reviewed for demographic data, operative intervention, mechanism of injury, mortality, comorbidities, and other factors. Computed tomography (CT) was used to determine the muscle cross-sectional area and to calculate the skeletal muscle index. The database revealed 192 patients coded for acetabular fracture; of these, 181 were correctly diagnosed. Ninety-nine patients had recorded body mass index (BMI) and adequate CT scans to measure the skeletal muscle index. Forty-two patients (42.4%) had sarcopenia, and 57 patients (57.6%) did not have sarcopenia. There were no significant differences in demographic characteristics between the groups with the exception of BMI and sex. BMI was higher in patients who did not have sarcopenia (31.7 kg/m) than it was in patients with sarcopenia (23.6 kg/m) (p sarcopenia at 76.2% (32 of 42 patients) than in patients without sarcopenia at 50.9% (29 of 57 patients). Fractures in patients without sarcopenia were associated with a higher-energy mechanism of injury in 78.9% of cases compared with 52.4% of cases of patients with sarcopenia (p = 0.005). Sarcopenia was significantly associated (p = 0.0419) with increased 1-year mortality (28.6%) compared with the absence of sarcopenia (12.3%). This association was even stronger if in-hospital mortality was excluded (p = 0.00074). Finally

  8. Tear-Film Evaporation Rate from Simultaneous Ocular-Surface Temperature and Tear-Breakup Area.

    Science.gov (United States)

    Dursch, Thomas J; Li, Wing; Taraz, Baseem; Lin, Meng C; Radke, Clayton J

    2018-01-01

    A corneal heat-transfer model is presented to quantify simultaneous measurements of fluorescein tear-breakup area (TBA) and ocular-surface temperature (OST). By accounting for disruption of the tear-film lipid layer (TFLL), we report evaporation rates through lipid-covered tear. The modified heat-transfer model provides new insights into evaporative dry eye. A quantitative analysis is presented to assess human aqueous tear evaporation rate (TER) through intact TFLLs from simultaneous in vivo measurement of time-dependent infrared OST and fluorescein TBA. We interpret simultaneous OST and TBA measurements using an extended heat-transfer model. We hypothesize that TBAs are ineffectively insulated by the TFLL and therefore exhibit higher TER than does that for a well-insulting TFLL-covered tear. As time proceeds, TBAs increase in number and size, thereby increasing the cornea area-averaged TER and decreasing OST. Tear-breakup areas were assessed from image analysis of fluorescein tear-film-breakup video recordings and are included in the heat-transfer description of OST. Model-predicted OSTs agree well with clinical experiments. Percent reductions in TER of lipid-covered tear range from 50 to 95% of that for pure water, in good agreement with literature. The physical picture of noninsulating or ruptured TFLL spots followed by enhanced evaporation from underlying cooler tear-film ruptures is consistent with the evaporative-driven mechanism for local tear rupture. A quantitative analysis is presented of in vivo TER from simultaneous clinical measurement of transient OST and TBA. The new heat-transfer model accounts for increased TER through expanding TBAs. Tear evaporation rate varies strongly across the cornea because lipid is effectively missing over tear-rupture troughs. The result is local faster evaporation compared with nonruptured, thick lipid-covered tear. Evaporative-driven tear-film ruptures deepen to a thickness where fluorescein quenching commences and local

  9. Acetabular fractures following rugby tackles: a case series

    LENUS (Irish Health Repository)

    Good, Daniel W

    2011-10-05

    Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old) who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting \\'the tackle\\' to only two players may well reduce the likelihood of this life-altering injury.

  10. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  11. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular...

  12. Computed tomography assessment of hip joints in asymptomatic individuals in relation to femoroacetabular impingement.

    Science.gov (United States)

    Kang, Alan C L; Gooding, Andrew J; Coates, Mark H; Goh, Tony D; Armour, Paul; Rietveld, John

    2010-06-01

    Femoroacetabular impingement has become a well-recognized entity predisposing to acetabular labral tears and chondral damage, and subsequently development of osteoarthritis of the hip joint. In the authors' experience, it is common to see bony abnormalities predisposing to femoroacetabular impingement in the contralateral asymptomatic hips in patients with unilateral femoroacetabular impingement. This study was undertaken to investigate the prevalence of bony abnormalities predisposing to femoroacetabular impingement in asymptomatic individuals without exposing study participants to unnecessary radiation. Cross-sectional study; Level of evidence, 4. Fifty individuals (100 hip joints), ranging from 15 to 40 years of age, who were seen at a local hospital between March and August 2008 with abdominal trauma or nonspecific abdominal pain in whom abdominal computed tomography was performed to aid diagnosis were prospectively studied. These patients were not known to have any history of hip-related problems. Raw data from the abdominal computed tomography scan, performed on a 64-slice multidetector computed tomography scanner, were reformatted using bone algorithm into several different planes. Several measurements and observations of the hip joints were made in relation to femoroacetabular impingement. The 100 hip joints from 50 patients with no history of hip problems demonstrated that 39% of the joints (31% of female, 48% of male joints) have at least 1 morphologic aspect predisposing to femoroacetabular impingement. The majority (66% to 100% ) of the findings were bilateral; 33% of female and 52% of male asymptomatic participants in our study had at least 1 predisposing factor for femoroacetabular impingement in 1 or both of their hip joints. Based on the data collected from this study, the acetabular crossover sign had a 71% sensitivity and 88% specificity for detecting acetabular retroversion. Nonquantitative assessment of the femoral head at the anterior

  13. Cranial acetabular retroversion is common in developmental dysplasia of the hip as assessed by the weight bearing position

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mikkelsen, Lone Rømer; Jacobsen, Steffen

    2010-01-01

    The appearance of acetabular version differs between the supine and weight bearing positions in developmental dysplasia of the hip. Weight bearing radiographic evaluation has been recommended to ensure the best coherence between symptoms, functional appearance, and hip deformities. Previous...... prevalence estimates of acetabular retroversion in dysplastic hips have been established in radiographs recorded with the patient supine and with inclusion only if pelvic tilt met standardized criteria. We assessed the prevalence and the extent of acetabular retroversion in dysplastic hip joints in weight...

  14. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    Science.gov (United States)

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    LENUS (Irish Health Repository)

    Banks, Louisa N

    2012-02-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient\\'s weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  16. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    Science.gov (United States)

    Banks, Louisa N; McElwain, John P

    2010-04-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  17. Tearing instabilities in turbulence

    International Nuclear Information System (INIS)

    Ishizawa, A.; Nakajima, N.

    2009-01-01

    Full text: Effects of micro-turbulence on tearing instabilities are investigated by numerically solving a reduced set of two-fluid equations. Micro-turbulence excites both large-scale and small-scale Fourier modes through energy transfer due to nonlinear mode coupling. The energy transfer to large scale mode does not directly excite tearing instability but it gives an initiation of tearing instability. When tearing instability starts to grow, the excited small scale mode plays an important role. The mixing of magnetic flux by micro-turbulence is the dominant factor of non-ideal MHD effect at the resonant surface and it gives rise to magnetic reconnection which causes tearing instability. Tearing instabilities were investigated against static equilibrium or flowing equilibrium so far. On the other hand, the recent progress of computer power allows us to investigate interactions between turbulence and coherent modes such as tearing instabilities in magnetically confined plasmas by means of direct numerical simulations. In order to investigate effects of turbulence on tearing instabilities we consider a situation that tearing mode is destabilized in a quasi-equilibrium including micro-turbulence. We choose an initial equilibrium that is unstable against kinetic ballooning modes and tearing instabilities. Tearing instabilities are current driven modes and thus they are unstable for large scale Fourier modes. On the other hand kinetic ballooning modes are unstable for poloidal Fourier modes that are characterized by ion Larmor radius. The energy of kinetic ballooning modes spreads over wave number space through nonlinear Fourier mode coupling. We present that micro-turbulence affects tearing instabilities in two different ways by three-dimensional numerical simulation of a reduced set of two-fluid equations. One is caused by energy transfer to large scale modes, the other is caused by energy transfer to small scale modes. The former is the excitation of initial

  18. Divalent cations in tears, and their influence on tear film stability in humans and rabbits.

    Science.gov (United States)

    Wei, Xiaojia Eric; Markoulli, Maria; Millar, Thomas J; Willcox, Mark D P; Zhao, Zhenjun

    2012-06-05

    Reduced tear film stability is reported to contribute to dry eye. Rabbits are known to have a more stable tear film than humans. Thus, we sought to examine the tears of rabbits and humans for metal cations, and to test how they influence tear film stability. Tears were collected from 10 healthy humans and 6 rabbits. Tear osmolality was measured by vapor pressure osmometer, and metals analyzed using inductively coupled plasma (ICP) mass spectrometry or ICP atomic emission spectroscopy. The influence of divalent cations on tears was analyzed by measuring surface tension using the Langmuir trough in vitro, using different concentrations of cations in the subphase, and grading the tear break-up in rabbits in vivo after instillation of chelating agents. Rabbit tears had a higher osmolality compared to humans. Major metals did not differ between species; however, rabbits had higher levels of Mg(2+) (1.13 vs. 0.39 mM) and Ca(2+) (0.75 vs. 0.36 mM). In rabbit tears in vitro, diminishing divalent cations resulted in a decrease in the maximum surface pressure from 37 to 30 mN/m. In vivo, an increase in the amount of tear film that was broken-up was found. In contrast, when changing divalent cation concentrations in human tears, the maximum surface pressure remained at 26 mN/m. The normal osmolality of rabbit tears is significantly higher than that in humans. While divalent cations had little influence on human tears, they appear to have an important role in maintaining tear film stability in rabbits.

  19. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    Science.gov (United States)

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  1. Acetabular retroversion as a rare cause of chronic hip pain: recognition of the ''figure-eight'' sign

    Energy Technology Data Exchange (ETDEWEB)

    Banks, Kevin P. [Brooke Army Medical Center, Department of Radiology, Fort Sam Houston, TX (United States); Grayson, David E. [Wilford Hall Medical Center, Department of Radiology, Lackland Air Force Base, TX (United States)

    2007-06-15

    While well-recognized in the orthopedic literature as a cause of chronic hip pain, acetabular retroversion has not been specifically described in the radiologic literature. Acetabular retroversion represents a particular form of hip dysplasia characterized by abnormal posterolateral orientation of the acetabulum. This pathophysiology predisposes the individual to subsequent anterior impingement of the femoral neck upon the anterior acetabular margin and fibrous labrum. Without treatment, cases may progress to damage of the anterior labrum and cartilage, with eventual early onset of osteoarthritic disease. This impinging condition has been described as occurring in isolation or as part of a complex dysplasia. We describe two cases of acetabular retroversion diagnosed by conventional radiographic evaluation of the pelvis, one in isolation and one occurring in the setting of a larger congenital syndrome. These cases illustrate the utility of the ''figure-eight'' sign in identifying abnormalities of acetabular version and thus assisting clinicians in properly identifying these individuals so that appropriate therapy may be instituted. (orig.)

  2. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    International Nuclear Information System (INIS)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide

    2012-01-01

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  3. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan)

    2012-11-15

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  4. Determinación del desgaste del componente acetabular en prótesis totales de cadera. // Wear determination of acetabular component in total hip prosthesis.

    Directory of Open Access Journals (Sweden)

    G. García del Pino

    2002-01-01

    Full Text Available En este trabajo se realiza un estudio a través del Método de los Elementos Finitos “MEF” sobre el desgaste del componenteacetabular durante el ciclo de marcha y considerando algunos casos extremos de cargas como subir y bajar escaleras,levantarse de una silla, etc. Utilizando el MEF fueron modelados independientemente los componentes acetabular yfemoral de la prótesis total de cadera y puestos en contacto posteriormente. Fueron estudiadas varias posiciones delacetábulo así como diferentes casos de carga simulando pacientes con diferente peso corporal y actividades físicas. Paraevaluar los resultados se crearon rutinas en lenguaje C que organizaron los mismos para un tratamiento estadísticoposterior.Palabras claves: biomecánica, ortopedia, elementos finitos, modelación, desgaste, prótesis de cadera.___________________________________________________________________________Abstract.A wear study of acetabular component during the marching cycle, considering some extreme loads cases as: ascend anddescend stairways, get up from a seat, etc , by means of Finite Elements Method ( FEM , is carried out. The acetabular andfemoral component of the total hip prosthesis were independently modeled and placed in contact lastly. Several acetabulpositions were studied as well as different load cases, simulating patients with different body weight and different physicalactivities. To evaluate the results routines in C language were created in order to organized the same ones for a laterstatistical treatment.Key words. biomechanics, ortophedy, finite elements, modelation, wear, hip bone prosthesis.

  5. Mastering the Physical Examination of the Athlete's Hip.

    Science.gov (United States)

    Trofa, David P; Mayeux, Sophie E; Parisien, Robert L; Ahmad, Christopher S; Lynch, T Sean

    In this review, we describe precise methods for evaluating the athlete's hip or groin with an emphasis on recognizing the most common extra-articular and intra-articular pathologies, including adductor strains, athletic pubalgia, osteitis pubis, and femoroacetabular impingement with labral tears.

  6. Prophylactic post-operative radiotherapy prevents heterotopic ossification following traumatic acetabular fracture

    International Nuclear Information System (INIS)

    Meyer, Joseph T.; Hixson, William C.; Jennelle, Richard L. S.; Alonso, Jorge E.; Raben, David; Spencer, Sharon S.; Kim, Robert Y.

    1996-01-01

    Purpose/Objective: To determine the effect of post-operative radiation on the incidence of heterotopic ossification following traumatic acetabular fracture. Materials and Methods: A retrospective analysis was performed of the medical records and radiographs of all patients who received prophylactic radiotherapy to prevent heterotopic ossification. These results were compared to a similar group of patients receiving no prophylactic radiotherapy following traumatic acetabular fracture. Between 1987 and 1994, sixty-six patients received prophylactic radiotherapy to prevent heterotopic ossification. Results: Thirty-six patients (55%) received radiotherapy following operative repair of a traumatic acetabular fracture (median follow-up: 210 days). Three dose schedules were utilized: (28(36)) (77.8%) received 700 cGy/1 fx, (2(36)) (5.5%) 800 cGy/1 fx, and (6(36)) (16.7%) 1000 cGy/5 fxs. These patients were retrospectively compared with thirty-four patients who received similar operative management of traumatic acetabular fractures without post-operative radiotherapy (median follow-up: 378 days). Of the patients with heterotopic ossification, 96% developed it within 180 days. Complications and delayed wound healing rates were not significantly different in patients treated with or without post-operative radiotherapy, 6.4% and 6.3% respectively (p=0.49). The incidence of heterotopic ossification at last follow-up in patients treated with and without post-operative radiotherapy was (5(36)) (13.9%) and (19(34)) (55.9%), respectively (p=0.000332). For all patients, type of surgical approach was associated with development of heterotopic ossification: posterior, (7(38)) (18.4%), ilio-inguinal (1(3)) (33.3%), tri-radiate (13(19)) (68.4%), p=.000511. In patients receiving post-operative radiotherapy, variables associated with heterotopic ossification included dose (p=.00962), injury-to-radiation interval (p=.0038), and surgery-to-radiation interval (p=.0238). Fifty percent ((3

  7. Acetabular fractures following rugby tackles: a case series

    Directory of Open Access Journals (Sweden)

    Morris Seamus

    2011-10-01

    Full Text Available Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting 'the tackle' to only two players may well reduce the likelihood of this life-altering injury.

  8. Meniscus Tears (For Teens)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Meniscus Tears KidsHealth / For Teens / Meniscus Tears What's in this ... surgery to fix it. What Is a Meniscus Tear? Your knee is made up of three bones: ...

  9. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    Energy Technology Data Exchange (ETDEWEB)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong (Second Hospital Affiliated to the Medical College of Xi' an Jiaotong Univ., Xi' an Shaanxi (China))

    2009-08-15

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8+-2.1 mm and 7.1+-3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  10. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    International Nuclear Information System (INIS)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong

    2009-01-01

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8±2.1 mm and 7.1±3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  11. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion

  12. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  13. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  14. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    Science.gov (United States)

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  15. Human tears contain a chemosignal.

    Science.gov (United States)

    Gelstein, Shani; Yeshurun, Yaara; Rozenkrantz, Liron; Shushan, Sagit; Frumin, Idan; Roth, Yehudah; Sobel, Noam

    2011-01-14

    Emotional tearing is a poorly understood behavior that is considered uniquely human. In mice, tears serve as a chemosignal. We therefore hypothesized that human tears may similarly serve a chemosignaling function. We found that merely sniffing negative-emotion-related odorless tears obtained from women donors induced reductions in sexual appeal attributed by men to pictures of women's faces. Moreover, after sniffing such tears, men experienced reduced self-rated sexual arousal, reduced physiological measures of arousal, and reduced levels of testosterone. Finally, functional magnetic resonance imaging revealed that sniffing women's tears selectively reduced activity in brain substrates of sexual arousal in men.

  16. Antimicrobial compounds in tears.

    Science.gov (United States)

    McDermott, Alison M

    2013-12-01

    The tear film coats the cornea and conjunctiva and serves several important functions. It provides lubrication, prevents drying of the ocular surface epithelia, helps provide a smooth surface for refracting light, supplies oxygen and is an important component of the innate defense system of the eye providing protection against a range of potential pathogens. This review describes both classic antimicrobial compounds found in tears such as lysozyme and some more recently identified such as members of the cationic antimicrobial peptide family and surfactant protein-D as well as potential new candidate molecules that may contribute to antimicrobial protection. As is readily evident from the literature review herein, tears, like all mucosal fluids, contain a plethora of molecules with known antimicrobial effects. That all of these are active in vivo is debatable as many are present in low concentrations, may be influenced by other tear components such as the ionic environment, and antimicrobial action may be only one of several activities ascribed to the molecule. However, there are many studies showing synergistic/additive interactions between several of the tear antimicrobials and it is highly likely that cooperativity between molecules is the primary way tears are able to afford significant antimicrobial protection to the ocular surface in vivo. In addition to effects on pathogen growth and survival some tear components prevent epithelial cell invasion and promote the epithelial expression of innate defense molecules. Given the protective role of tears a number of scenarios can be envisaged that may affect the amount and/or activity of tear antimicrobials and hence compromise tear immunity. Two such situations, dry eye disease and contact lens wear, are discussed here. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Tear progression of symptomatic full-thickness and partial-thickness rotator cuff tears as measured by repeated MRI.

    Science.gov (United States)

    Kim, Yang-Soo; Kim, Sung-Eun; Bae, Sung-Ho; Lee, Hyo-Jin; Jee, Won-Hee; Park, Chang Kyun

    2017-07-01

    The purpose of this study was to analyse the natural course of symptomatic full-thickness and partial-thickness rotator cuff tears treated non-operatively and to identify risk factors affecting tear enlargement. One hundred and twenty-two patients who received non-surgical treatment for a partial- or full-thickness supraspinatus tear were included in this study. All rotator cuff tears were diagnosed with magnetic resonance imaging (MRI), and the same modality was used for follow-up studies. Follow-up MRI was performed after at least a 6-month interval. We evaluated the correlation between tear enlargement and follow-up duration. Eleven risk factors were analysed by both univariate and multivariate analyses to identify factors that affect enlargement of rotator cuff tears. The mean follow-up period was 24.4 ± 19.5 months. Out of 122 patients, 34 (27.9%) patients had an initial full-thickness tear and 88 (72.1%) patients had a partial-thickness tear. Considering all patients together, tear size increased in 51/122 (41.8%) patients, was unchanged in 65/122 (53.3%) patients, and decreased in 6/122 (4.9%) patients. Tear size increased for 28/34 (82.4%) patients with full-thickness tears and 23/88 (26.1%) patients with partial-thickness tears. From the two groups which were followed over 12 months, a higher rate of enlargement was observed in full-thickness tears than in partial-thickness tears (6-12 months, n.s.; 12-24 months, P = 0.002; over 24 months, P rotator cuff tears and 23/88 (26.1%) of symptomatic partial-thickness tears increased in size over a follow-up period of 6-100 months. Full-thickness tears showed a higher rate of enlargement than partial-thickness tears regardless of the follow-up duration. Univariate and multivariate analyses suggested that full-thickness tear was the most reliable risk factor for tear enlargement. The clinical relevance of these observations is that full-thickness rotator cuff tears treated conservatively should be

  18. Para-acetabular peritendinitis calcarea; its radiographic manifestations

    International Nuclear Information System (INIS)

    Kawashima, Akira; Murayama, Sadayuki; Ohuchida, Toshiyuki; Russell, W.J.

    1987-02-01

    Peritendinitis calcarea and os acetabuli have long been confused during interpretations of hip-joint radiographs. Such confusion is reflected in the medical literature. The present study differentiated these two entities according to their interval radiographic progression and regression. There were 137 instances of para-acetabular calcifications among 110 subjects (59 men and 51 women), whose mean age was 46.8 years at the time of their initial detection. Twenty-six of the subjects had lumbago, which was probably unrelated. Other abnormalities including narrowed intervertebral spaces, scoliosis, and spondylolysis were observed in 21 of the subjects. These could have been responsible for any symptoms they had had, but none of the subjects complained of local hip-joint pain when the radiographs in question were made. Ninety-three of these instances of calcification were reviewed by means of serial radiographs. Interval changes in the sizes and shapes of the calcifications occurred among 90 of them, indicative of the latent type of peritendinitis calcarea. No interval changes were noted in the remaining three cases, indicating they were secondary ossification centers; namely, os acetabuli. This study showed that in asymptomatic adults, most para-acetabular calcifications were really not os acetabuli, but actually peritendinitis calcarea. (author)

  19. Examination of rotator cuff re-tear

    International Nuclear Information System (INIS)

    Kitahara, Hiroyuki; Yabe, Yoshihiro; Norimatsu, Takahiro; Adachi, Shinji; Sera, Keisuke

    2010-01-01

    The six-month post-operative re-tear rate in 72 arthroscopic rotator cuff repair cases was 16.3% by MRI. The re-tear rate of massive tears was 50%. We investigated the details of the re-tears by MRI and arthroscopic findings. High re-tear rates were connected with cuff tear size and fatty degeneration of muscle belly. Cases with poor cuff quality in arthroscopically showed high re-tear rate. These results suggest that surgery operation should be performed as soon as possible after diagnosis of cuff tear to obtain good results. Cases with damage of long head of the biceps (LHB) are likely to develop impingement causes of re-tears. Some type of rehabilitation is required to avoid impingement in such cases. (author)

  20. Ketofol for monitored anesthesia care in shoulder arthroscopy and labral repair: a case report

    OpenAIRE

    Lee, Kevin C; Shi, Hanyuan; Lee, Brian C

    2016-01-01

    Kevin C Lee,1 Hanyuan Shi,2 Brian C Lee3 1Columbia University College of Dental Medicine, New York, NY, 2Vanderbilt University School of Medicine, Nashville, TN, 3Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA Abstract: A 21-year-old male (body mass index: 28.3) with a history of asthma and reactive airway disease since childhood underwent left shoulder arthroscopy and labral repair surgery under monitored anesthesia care. Because the procedure was perform...

  1. What emotional tears convey : Tearful individuals are seen as warmer, but also as less competent

    NARCIS (Netherlands)

    van de Ven, Niels; Meijs, Maartje; Vingerhoets, A.J.J.M.

    Earlier research found that the mere sight of tears promotes the willingness to provide support to the person shedding the tears. Other research, however, found that deliberate responses towards tearful persons could be more negative as well. We think this is because tears have ambivalent effects on

  2. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  3. early experience of operative treatment of pelvic and acetabular

    African Journals Online (AJOL)

    Objective: To review early post-operative results of pelvic and acetabular fracture intern al fixation. Design: ... 600 needing operative treatment annually. ... Infection was controlled with debridement and antibiotics. All the patients in the study returned to their work except one who has yet to do so 5 months after his injury.

  4. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    Science.gov (United States)

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  5. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients.

    Science.gov (United States)

    Eissa, Iman M; Khalil, Noha M; El-Gendy, Heba A

    2016-01-01

    Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P = 0.002), with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  6. TFOS DEWS II Tear Film Report.

    Science.gov (United States)

    Willcox, Mark D P; Argüeso, Pablo; Georgiev, Georgi A; Holopainen, Juha M; Laurie, Gordon W; Millar, Tom J; Papas, Eric B; Rolland, Jannick P; Schmidt, Tannin A; Stahl, Ulrike; Suarez, Tatiana; Subbaraman, Lakshman N; Uçakhan, Omür Ö; Jones, Lyndon

    2017-07-01

    The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Assessment of lamellar tearing

    International Nuclear Information System (INIS)

    McEnerney, J.W.

    1978-03-01

    Information on lamellar tearing is summarized and related to proposed ASME Code requirements. Lamellar tearing is characterized as a complex phenomenon related to poor short transverse ductility and through-thickness strain. The material, welding, and design variables that affect lamellar tearing are shown to be complex and interrelated. The commonly reported tests for assessing material susceptibility are described, with the controversy over their validity being carefully detailed. Although the use of a nondestructive test such as ultrasonic examination is most desirable, a widely applicable test method does not appear to be available. Of the destructive tests, the short transverse tensile reduction-of-area currently offers the most applicable means of assessing material susceptibility. However, because of the importance of matrix toughness, the short transverse Charpy V-notch test should be considered for use as an additional test if acceptance limits are developed. The ultrasonic detection of lamellar tears is susceptible to interpretation errors, which can make it overly conservative and lead to unnecessary repairs. The repair of tears is described as costly, difficult, and sometimes ineffective. Current design requirements appear to preclude any failures during static and fatigue service loads. However, without improvement of short transverse ductility, certain dynamic service loads could cause lamellar tearing failures. Two alternate design paths are recommended to prevent tearing during fabrication or service loading. The current and proposed ASME requirements dealing with lamellar tearing are reviewed and recommendations are made

  8. Clinical and Radiological Results over the Medium Term of Isolated Acetabular Revision

    Directory of Open Access Journals (Sweden)

    Nicola Piolanti

    2014-01-01

    Full Text Available Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60 of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32. 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1% showed thigh pain and only 4 hips (12.11% presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.

  9. MR imaging of subscapularis tendon injury in the setting of anterior shoulder dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Gyftopoulos, Soterios; Carpenter, Elizabeth; Kazam, Jonathan; Babb, James; Bencardino, Jenny [NYU Hospital for Joint Diseases, New York, NY (United States)

    2012-11-15

    To evaluate the degree and location patterns of subscapularis tendon injury in patients with prior anterior shoulder dislocation (ASD). Forty-five consecutive MR shoulder examinations in patients with a history of ASD and 20 consecutive MR examinations in patients without prior dislocation were reviewed. Two readers assessed for the presence and location of tendinosis and tearing in the subscapularis tendon, which was divided into three segments: superior, middle, and inferior. The readers also documented the presence of anterior labral tears, osseous Bankart defects and Hill-Sachs lesions. Fisher's exact tests were performed to analyze the different types of pathology and their locations. Subscapularis tendinosis, and partial thickness and full thickness tears were more common in patients with a history of ASD. Tendinosis was found in 60-64.4% of the dislocation patients compared with 40% of the non-dislocation group. When stratified by location, the middle and inferior thirds were the most commonly affected with statistical significance (p < 0.05) found in tearing of the inferior third. Anterior labral tears, osseous Bankart defects, and Hill-Sachs lesions were more common in the dislocation group with statistically significant associations with tendinosis in the middle and inferior thirds and tearing of the middle third (p < 0.05). Our study suggests an association between middle and inferior subscapularis tendon pathology and prior anterior shoulder dislocation. Based on our results, careful MR assessment of the subscapularis tendon by the radiologist is indicated in the setting of ASD as injury of this structure can be symptomatic and may be amenable to treatment. (orig.)

  10. MR imaging of subscapularis tendon injury in the setting of anterior shoulder dislocation

    International Nuclear Information System (INIS)

    Gyftopoulos, Soterios; Carpenter, Elizabeth; Kazam, Jonathan; Babb, James; Bencardino, Jenny

    2012-01-01

    To evaluate the degree and location patterns of subscapularis tendon injury in patients with prior anterior shoulder dislocation (ASD). Forty-five consecutive MR shoulder examinations in patients with a history of ASD and 20 consecutive MR examinations in patients without prior dislocation were reviewed. Two readers assessed for the presence and location of tendinosis and tearing in the subscapularis tendon, which was divided into three segments: superior, middle, and inferior. The readers also documented the presence of anterior labral tears, osseous Bankart defects and Hill-Sachs lesions. Fisher's exact tests were performed to analyze the different types of pathology and their locations. Subscapularis tendinosis, and partial thickness and full thickness tears were more common in patients with a history of ASD. Tendinosis was found in 60-64.4% of the dislocation patients compared with 40% of the non-dislocation group. When stratified by location, the middle and inferior thirds were the most commonly affected with statistical significance (p < 0.05) found in tearing of the inferior third. Anterior labral tears, osseous Bankart defects, and Hill-Sachs lesions were more common in the dislocation group with statistically significant associations with tendinosis in the middle and inferior thirds and tearing of the middle third (p < 0.05). Our study suggests an association between middle and inferior subscapularis tendon pathology and prior anterior shoulder dislocation. Based on our results, careful MR assessment of the subscapularis tendon by the radiologist is indicated in the setting of ASD as injury of this structure can be symptomatic and may be amenable to treatment. (orig.)

  11. Tear dynamics in healthy and dry eyes.

    Science.gov (United States)

    Cerretani, Colin F; Radke, C J

    2014-06-01

    Dry-eye disease, an increasingly prevalent ocular-surface disorder, significantly alters tear physiology. Understanding the basic physics of tear dynamics in healthy and dry eyes benefits both diagnosis and treatment of dry eye. We present a physiological-based model to describe tear dynamics during blinking. Tears are compartmentalized over the ocular surface; the blink cycle is divided into three repeating phases. Conservation laws quantify the tear volume and tear osmolarity of each compartment during each blink phase. Lacrimal-supply and tear-evaporation rates are varied to reveal the dependence of tear dynamics on dry-eye conditions, specifically tear osmolarity, tear volume, tear-turnover rate (TTR), and osmotic water flow. Predicted periodic-steady tear-meniscus osmolarity is 309 and 321 mOsM in normal and dry eyes, respectively. Tear osmolarity, volume, and TTR all match available clinical measurements. Osmotic water flow through the cornea and conjunctiva contribute 10 and 50% to the total tear supply in healthy and dry-eye conditions, respectively. TTR in aqueous-deficient dry eye (ADDE) is only half that in evaporative dry eye (EDE). The compartmental periodic-steady tear-dynamics model accurately predicts tear behavior in normal and dry eyes. Inclusion of osmotic water flow is crucial to match measured tear osmolarity. Tear-dynamics predictions corroborate the use of TTR as a clinical discriminator between ADDE and EDE. The proposed model is readily extended to predict the dynamics of aqueous solutes such as drugs or fluorescent tags.

  12. Quantitative analysis of tear film fluorescence and discomfort during tear film instability and thinning.

    Science.gov (United States)

    Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping

    2013-04-12

    The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.

  13. Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study.

    Directory of Open Access Journals (Sweden)

    Zhenfei Huang

    Full Text Available Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D details and tactile feedback of real fractures. Virtual reality (VR and 3D printing (3DP techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM, VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.

  14. Posterior horn lateral meniscal tears simulating meniscofemoral ligament attachment in the setting of ACL tear: MRI findings

    International Nuclear Information System (INIS)

    Park, Lawrence S.; Jacobson, Jon A.; Jamadar, David A.; Caoili, Elaine; Kalume-Brigido, Monica; Wojtys, Edward

    2007-01-01

    We have noted apparent far lateral meniscal attachment of the meniscofemoral ligament (MFL) with an anterior cruciate ligament (ACL) tear. This study evaluates MFL attachment and association with posterior horn lateral meniscus (PHLM) tear. Nine months of knee arthroscopy reports were reviewed to classify the PHLM and ACL as torn or normal. After excluding those with prior knee surgery, MR images were reviewed by two radiologists to determine the number of images lateral to PCL, which showed the ligaments of Humphrey and Wrisberg visible as structures separate from the PHLM. Any patient with abnormal PHLM surface signal not continuous with the MFL was excluded. MRI findings were compared with arthroscopy using Student's t test and Fisher's exact test. Of the 54 participants, 5 had PHLM tears and 49 were normal. Twenty-one had ACL tears; all those with an PHLM tear had an ACL tear. The ligament of Humphrey inserted on average 0.9 consecutive images lateral to the PCL without an PHLM tear and 4.7 with an PHLM tear; the ligament of Wrisberg inserted on average 3.0 consecutive images without an PHLM tear and 4.5 with an PHLM tear (slice thickness/gap = 3 mm/0.5 mm). There was a significant association between PHLM tear and number of images (p = 0.0028), and between ACL tear and this type of PHLM tear (p = 0.0064). Apparent far lateral meniscal extension of a meniscofemoral ligament (greater than or equal to four images lateral to the PCL) should be considered as a possible PHLM tear, especially in the setting of an ACL tear. (orig.)

  15. Revision of migrated pelvic acetabular components in THA with or without vascular involvement

    Directory of Open Access Journals (Sweden)

    Ștefan Cristea

    2016-05-01

    Full Text Available Purpose. The literature describes a high rate of mortality in cases of intrapelvic acetabular component migration, which is a rare but serious complication. Our aim is to establish and propose a treatment protocol according to our results and experience. Material and Methods. We performed eight (8 total hip revisions with acetabular cup migration between 2006 and 2012. A vascular graft was needed in four (4 of these cases. Two (2 cases were revisions after a spacer for infected arthroplasties. The protocol included the following: X-Ray examination (frontal and lateral views, CT angiography, a biological evaluation, a suitable pre-operative plan, at least six (6 units of blood stock, an experienced anesthesiologist, an experienced surgical team that included a vascular surgeon and a versatile arsenal of revision prostheses, bone grafts and vascular grafts. The anterolateral approach was generally used for hip revisions and the retroperitoneal approach in the dorsal decubitus position was used when vascular risk was involved. Results: The acetabular defect was reconstructed using bone grafts and tantalum revision cups in 4 cases, Burch-Schneider cages in 2 cases, a Kerboull ring in 1 case and a cementless oblong cup (Cotyle Espace in 1 case. In 4 cases, an iliac vessel graft procedure was conducted by the vascular surgeon. All patients survived the revision procedures and returned regularly for subsequent check-ups, during which they did not show any septic complications. Conclusions: Intrapelvic acetabular cup migration is a rare but serious complication that can occur after total hip arthroplasty in either septic or aseptic cases. An experienced, multidisciplinary team of surgeons should be involved in planning and conducting such complicated revisions.

  16. Early Versus Late Weight-Bearing Protocols for Surgically Managed Posterior Wall Acetabular Fractures.

    Science.gov (United States)

    Heare, Austin; Kramer, Nicholas; Salib, Christopher; Mauffrey, Cyril

    2017-07-01

    Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematically reviewed the current literature to determine if a difference in outcome exists between early and late postoperative weight-bearing protocols for surgically managed posterior wall acetabular fractures. PubMed and MEDLINE were searched for posterior wall acetabular fracture studies that included weight-bearing protocols and Merle d'Aubigné functional scores. Twelve studies were identified. Each study was classified as either early or late weight bearing. Early weight bearing was defined as full, unrestricted weight bearing at or before 12 weeks postoperatively. Late weight bearing was defined as restricted weight bearing for greater than 12 weeks postoperatively. The 2 categories were then compared by functional score using a 2-tailed t test and by complication rate using chi-square analysis. Six studies (152 fractures) were placed in the early weight-bearing category. Six studies (302 fractures) were placed in the late weight-bearing category. No significant difference in Merle d'Aubigné functional scores was found between the 2 groups. No difference was found regarding heterotopic ossification, avascular necrosis, superficial infections, total infections, or osteoarthritis. This systematic review found no difference in functional outcome scores or complication rates between early and late weight-bearing protocols for surgically treated posterior wall fractures. [Orthopedics. 2017: 40(4):e652-e657.]. Copyright 2017, SLACK Incorporated.

  17. A Controlled Study on the Correlation between Tear Film Volume and Tear Film Stability in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Iman M. Eissa

    2016-01-01

    Full Text Available Purpose. To assess the tear film quantity and correlate it with the quality and stability of the tear film in diabetics and compare them to age matched controls. Introduction. Diabetes affects tear film parameters in multiple ways. Poor metabolic control and neuropathy are postulated factors. To further understand how diabetes affects tear film parameters this study was conducted. Subjects and Methods. Tear meniscus height was measured by anterior segment OCT, along with tear thinning time, a subtype of noninvasive tear break-up time, and blinking rate per minute which were all recorded for 22 diabetic patients. Correlations between these tear film parameters were studied and then compared to 16 age matched controls. Results. A statistically significant difference was found in blinking rate between the diabetic and the control group (P=0.002, with higher blinking rate among diabetics. All tear film parameters were negatively correlated with duration of diabetes. A positive correlation was found between tear film volume and stability. Conclusion. Diabetes affects the tear film in various ways. Diabetics should be examined for dry eye signs even in absence of symptoms which may be masked by associated neuropathy. Duration of diabetes has an impact on tear film status.

  18. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  19. Software Simulation of Hot Tearing

    DEFF Research Database (Denmark)

    Andersen, S.; Hansen, P.N.; Hattel, Jesper Henri

    1999-01-01

    The brittleness of a solidifying alloy in a temperature range near the solidus temperature has been recognised since the fifties as the mechanism responsible for hot tearing. Due to this brittlenes, the metal will crack under even small amounts of strain in that temperature range. We see these hot...... tears in castings close to hot centres, where the level of strain is often too high.Although the hot tearing mechanism is well understood, until now it has been difficult to do much to reduce the hot tearing tendency in a casting. In the seventies, good hot tearing criteria were developed by considering...... the solidification rate and the strain rate of the hot tear prone areas. But, until recently it was only possible to simulate the solidification rate, so that the criteria could not be used effectively.Today, with new software developments, it is possible to also simulate the strain rate in the hot tear prone areas...

  20. Effects of topical cyclosporine a plus artificial tears versus artificial tears treatment on conjunctival goblet cell density in dysfunctional tear syndrome.

    Science.gov (United States)

    Demiryay, Elvan; Yaylali, Volkan; Cetin, Ebru Nevin; Yildirim, Cem

    2011-09-01

    The aim was to compare the effects of topical cyclosporine A and artificial tears combination with artificial tears alone in patients with dysfunctional tear syndrome (DTS). Forty-two eyes of 42 patients with DTS were enrolled in the study. The inclusion criteria for the study were Schirmer I (without anesthesia) scores below 10 mm/5 min and tear film break-up time (BUT) below 10 sec. The patients were randomly divided into two groups. The study group (22 patients) underwent 0.05% cyclosporine A treatment twice a day and preservative-free artificial tears for four times a day for 4 months. The control group (20 patients) was administered only preservative-free artificial tears four times a day for 4 months. The BUT, Schirmer test scores, corneal fluorescein staining, conjunctival lissamine green staining, and goblet cell density derived by impression cytology were recorded before and after treatment in each group. In the study group, all parameters improved statistically significantly after treatment at the 4-month follow-up compared with the pretreatment values (Ptears treatment significantly increases goblet cell density, decreases the signs of DTS, and improves ocular surface health.

  1. Femoroacetabular impingement

    International Nuclear Information System (INIS)

    Anderson, Suzanne E.; Siebenrock, Klaus Arno; Tannast, Moritz

    2012-01-01

    Femoroacetabular impingement (FAI) is a pathomechanical concept describing the early and painful contact of morphological changes of the hip joint, both on the acetabular, and femoral head sides. These can lead clinically to symptoms of hip and groin pain, and a limited range of motion with labral, chondral and bony lesions. Pincer impingement generally involves the acetabular side of the joint where there is excessive coverage of the acetabulum, which may be focal or more diffuse. There is linear contact of the acetabulum with the head/neck junction. Cam impingement involves the femoral head side of the joint where the head is associated with bony excrescences and is aspheric. The aspheric femoral head jams into the acetabulum. Imaging appearances are reviewed below. This type is evident in young males in the second and third decades. The main features of FAI are described.

  2. Classification of ulnar triangular fibrocartilage complex tears. A treatment algorithm for Palmer type IB tears.

    Science.gov (United States)

    Atzei, A; Luchetti, R; Garagnani, L

    2017-05-01

    The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.

  3. [Posterior partial trochanteric osteotomy for the treatment of the roof involved acetabular fractures].

    Science.gov (United States)

    Wang, Pan-Feng; Xu, Shuo-Gui; Zhang, Chun-Cai; Fu, Qing-Ge; Zhang, Yun-Tong; Liu, Xin-Wei; Niu, Yun-Fei; Tang, Yang

    2013-11-01

    To introduce a new trochanteric osteotomy,and evaluate the outcome of the procedure combined a posterior lateral approach in treating acetabular fractures which involving the roof. Between March 2007 and Novmber 2010,30 patients with displaced acetabular fractures involving the dome need trochanteric osteotomy were retrospectively reviewed. There were 21 males and 9 females,ranging in age from 18 to 70 years with an average of 35.2 years at the time of injury. According to Letournel-Judet classification, there were 10 posterior wall fractures,7 posterior column fractures,5 transverse fractures, 2 T-shape fractures, 1 transverse associated with posterior wall fracture, 3 posterior column and wall fractures and 2 bicolumn fractures. The standards of Matta,the modified Merle d'Aubigne-Postel, Medical Research Council were respectively used to evaluate the reduction result, function of hip joint and the strength of hip abduction. All patients were followed up with an average time of 25 months (18 to 40) and all osteotomy sites obtained bone union with an average time of 8.4 weeks (6 to 12). No bone non-union, bone block displaceing, internal fixation looseing and breaking,infection of deep part were found. Seventeen patients got anatomic reduction, 12 got satisfied reduction, and 1 got unsatisfied result according to the criteria of Matta. At final follow-up, function of hip joint obtained excellent results in 11 cases, good in 15, fair in 3 and poor in 1. The strength of the abductors of 3 patients were grade 4 and 27 patients were grade 5. Posterior partial great trochanteric osteotomy can enhance the exposure and provide a more accurate reduction and degrade the difficulty of acetabular fracture fixation without increasing the risk of complications. The method provide a new way for the treatment of the roof involved acetabular fractures.

  4. Artificial tears potpourri: a literature review

    Directory of Open Access Journals (Sweden)

    Moshirfar M

    2014-07-01

    Full Text Available Majid Moshirfar,1 Kasey Pierson,2,* Kamalani Hanamaikai,3,* Luis Santiago-Caban,1 Valliammai Muthappan,1 Samuel F Passi11Department of Ophthalmology, John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2University of Arizona College of Medicine, Phoenix, Phoenix, AZ, USA; 3A T Still University, School of Osteopathic Medicine in Arizona, Mesa, AZ, USA *These authors contributed equally to this work Abstract: Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. Keywords: dry eye, tear film, dysfunctional tear syndrome, ophthalmic lubricant, artificial tears, lipid layer, tear osmolarity, TBUT, Systane®, Refresh®, Blink®, GenTeal®, Soothe®, Lacrisert®, ocular surface inflammatory disease, Sjogren

  5. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures

    Directory of Open Access Journals (Sweden)

    Sandeep Gupta

    2017-06-01

    Conclusion: Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way.

  6. Idiopathic Bilateral Bloody Tearing

    Directory of Open Access Journals (Sweden)

    Emrullah Beyazyıldız

    2015-01-01

    Full Text Available Bloody tear is a rare and distinct clinic phenomenon. We report a case presenting with the complaint of recurrent episodes of bilateral bloody tearing. A 16-year-old girl presented to our clinic with complaint of bloody tearing in both eyes for 3 months. Bloody tearing was not associated with her menses. A blood-stained discharge from the punctum was not observed during the compression of both nasolacrimal ducts. Nasolacrimal passage was not obstructed. Imaging studies such as dacryocystography and gradient-echo magnetic resonance imaging (MRI of nasolacrimal canal were normal. Intranasal endoscopic evaluation was normal. We collected samples from bloody tears two times and pathological examination was performed. Pathological analysis showed lots of squamous cells and no endometrial cells; dysplastic cells were found. Further evaluations for underlying causes were unremarkable. No abnormalities were found in ophthalmologic, radiologic, and pathologic investigations. This condition is likely a rare abnormality and the least recognized aetiology for the idiopathic phenomenon.

  7. Efficacy of labral repair, biceps tenodesis, and diagnostic arthroscopy for SLAP Lesions of the shoulder: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Mowinckel Petter

    2010-10-01

    Full Text Available Abstract Background Surgery for type II SLAP (superior labral anterior posterior lesions of the shoulder is a promising but unproven treatment. The procedures include labral repair or biceps tenodesis. Retrospective cohort studies have suggested that the benefits of tenodesis include pain relief and improved function, and higher patient satisfaction, which was reported in a prospective non-randomised study. There have been no completed randomised controlled trials of surgery for type II SLAP lesions. The aims of this participant and observer blinded randomised placebo-controlled trial are to compare the short-term (6 months and long-term (2 years efficacy of labral repair, biceps tenodesis, and placebo (diagnostic arthroscopy for alleviating pain and improving function for type II SLAP lesions. Methods/Design A double-blind randomised controlled trial are performed using 120 patients, aged 18 to 60 years, with a history for type II SLAP lesions and clinical signs suggesting type II SLAP lesion, which were documented by MR arthrography and arthroscopy. Exclusion criteria include patients who have previously undergone operations for SLAP lesions or recurrent shoulder dislocations, and ruptures of the rotator cuff or biceps tendon. Outcomes will be assessed at baseline, three, six, 12, and 24 months. Primary outcome measures will be the clinical Rowe Score (1988-version and the Western Ontario Instability Index (WOSI at six and 24 months. Secondary outcome measures will include the Shoulder Instability Questionnaire (SIQ, the generic EuroQol (EQ-5 D and EQ-VAS, return to work and previous sports activity, complications, and the number of reoperations. Discussion The results of this trial will be of international importance and the results will be translatable into clinical practice. Trial Registration [ClinicalTrials.gov NCT00586742

  8. Percentage Level of Tannin fur Rabbit for Leather Concerning Stitch Tearing Strength, Tearing Strength and Flexibility

    Directory of Open Access Journals (Sweden)

    Mustakim Mustakim

    2012-02-01

    Full Text Available The purpose of this study was to find out the appropriate of tannin level for rabbit fur leather concerning stitch tearing strength, tearing strength, and flexibility. The result were expected to contribute good information for the society, leather craftsman, and further researchers about fur leather tanning especially rabbit fur leather with tannin concerning stitch tearing strength, tearing strength and flexibility. The material that used were 12 pieces of four months of rabbit skin. The research method was Completely Randomized Design, consist of three treatments of tannin, they were: M1 (mimosa 15%, M2 (mimosa 20%, and M3 (mimosa 25%. Each of treatment hold on four repetition, the variables which measured were stitch tearing strength, tearing strength, and flexibility of fur leather. Data were  analysed by analysis variance followed by Duncan’s Multiple Range Test. The result of this research indicate that the use level of tannin give significant influence (P<0.05 among stitch tearing strength, tearing strength. It gave a very significant influence (P<0.01 for flexibility of rabbit fur leather. Based on the result, can be concluded that 25 % of tannin (mimosa, produce the best  result on stitch tearing strength and tearing strength. The increase of tannin offer will decrease the flexibility of fur leather but the lowest tannin produced the best flexibility of fur leather (15 percent. The best quality of rabbit fur leather produced by 25 % of tannin.   Keywords : leather, tannin, quality

  9. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  10. Clinical Assessment of Physical Examination Maneuvers for Superior Labral Anterior to Posterior Lesions.

    Science.gov (United States)

    Somerville, Lyndsay E; Willits, Kevin; Johnson, Andrew M; Litchfield, Robert; LeBel, Marie-Eve; Moro, Jaydeep; Bryant, Dianne

    2017-10-01

    Purpose  Shoulder pain and disability pose a diagnostic challenge owing to the numerous etiologies and the potential for multiple disorders to exist simultaneously. The evidence to support the use of clinical tests for superior labral anterior to posterior complex (SLAP) is weak or absent. The purpose of this study is to determine the diagnostic validity of physical examination maneuvers for SLAP lesions by performing a methodologically rigorous, clinically applicable study. Methods  We recruited consecutive new shoulder patients reporting pain and/or disability. The physician took a history and indicated their certainty about each possible diagnosis ("certain the diagnosis is absent/present," or "uncertain requires further testing"). The clinician performed the physical tests for diagnoses where uncertainty remained. Magnetic resonance imaging arthrogram and arthroscopic examination were the gold standards. We calculated sensitivity, specificity, and likelihood ratios (LRs) and investigated whether combinations of the top tests provided stronger predictions. Results  Ninety-three patients underwent physical examination for SLAP lesions. When using the presence of a SLAP lesion (Types I-V) as disease positive, none of the tests was sensitive (10.3-33.3) although they were moderately specific (61.3-92.6). When disease positive was defined as repaired SLAP lesion (including biceps tenodesis or tenotomy), the sensitivity (10.5-38.7) and specificity (70.6-93.8) of tests improved although not by a substantial amount. None of the tests was found to be clinically useful for predicting repairable SLAP lesions with all LRs close to one. The compression rotation test had the best LR for both definitions of disease (SLAP tear present = 1.8 and SLAP repaired = 1.67). There was no optimal combination of tests for diagnosing repairable SLAP lesions, with at least two tests positive providing the best combination of measurement properties (sensitivity 46.1% and

  11. Hip arthroscopy protocol: expert opinions on post-operative weight bearing and return to sports guidelines.

    Science.gov (United States)

    Rath, Ehud; Sharfman, Zachary T; Paret, Matan; Amar, Eyal; Drexler, Michael; Bonin, Nicolas

    2017-01-01

    The objectives of this study are to survey the weight-bearing limitation practices and delay for returning to running and impact sports of high volume hip arthroscopy orthopedic surgeons. The study was designed in the form of expert survey questionnaire. Evidence-based data are scares regarding hip arthroscopy post-operative weight-bearing protocols. An international cross-sectional anonymous Internet survey of 26 high-volume hip arthroscopy specialized surgeons was conducted to report their weight-bearing limitations and rehabilitation protocols after various arthroscopic hip procedures. The International Society of Hip Arthroscopy invited this study. The results were examined in the context of supporting literature to inform the studies suggestions. Four surgeons always allow immediate weight bearing and five never offer immediate weight bearing. Seventeen surgeons provide weight bearing depending on the procedures performed: 17 surgeons allowed immediate weight bearing after labral resection, 10 after labral repair and 8 after labral reconstruction. Sixteen surgeons allow immediate weight bearing after psoas tenotomy. Twenty-one respondents restrict weight bearing after microfracture procedures for 3-8 weeks post-operatively. Return to running and impact sports were shorter for labral procedures and bony procedures and longer for cartilaginous and capsular procedures. Marked variability exists in the post-operative weight-bearing practices of hip arthroscopy surgeons. This study suggests that most surgeons allow immediate weight bearing as tolerated after labral resection, acetabular osteoplasty, chondroplasty and psoas tenotomy. For cartilage defect procedures, 6 weeks or more non-weight bearing is suggested depending on the area of the defect and lateral central edge angle. Delayed return to sports activities is suggested after microfracture procedures. The level of evidence was Level V expert opinions.

  12. Artificial tears potpourri: a literature review

    Science.gov (United States)

    Moshirfar, Majid; Pierson, Kasey; Hanamaikai, Kamalani; Santiago-Caban, Luis; Muthappan, Valliammai; Passi, Samuel F

    2014-01-01

    Numerous brands and types of artificial tears are available on the market for the treatment of dysfunctional tear syndrome. Past literature has focused on comparing the components of these products on patient’s clinical improvement. The wide array of products on the market presents challenges to both clinicians and patients when trying to choose between available tear replacement therapies. Different formulations affect patients based on etiology and severity of disease. In order to provide an unbiased comparison between available tear replacement therapies, we conducted a literature review of existing studies and National Institutes of Health clinical trials on commercially available, brand name artificial tears. Outcomes evaluated in each study, as well as the percent of patients showing clinical and symptomatic improvement, were analyzed. Fifty-one studies evaluating different brands of artificial tears, and their efficacy were identified. Out of the 51 studies, 18 were comparison studies testing brand name artificial tears directly against each other. Nearly all formulations of artificial tears provided significant benefit to patients with dysfunctional tear syndrome, but some proved superior to others. From the study data, a recommended treatment flowchart was derived. PMID:25114502

  13. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  14. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  15. Cam deformity and acetabular dysplasia as risk factors for hip osteoarthritis

    NARCIS (Netherlands)

    Hosnijeh, Fatemeh Saberi; Zuiderwijk, Maria E; Versteeg, Mathijs; Smeele, Hieronymus T W; Hofman, Albert; Uitterlinden, André G; Agricola, Rintje; Oei, Edwin H G; Waarsing, Jan H; Bierma-Zeinstra, Sita M; van Meurs, Joyce B J

    2017-01-01

    Objective: Cam deformity and acetabular dysplasia have been recognized as relevant risk factors for hip osteoarthritis (OA) in a few prospective studies with limited sample sizes. To date, however, no evidence is available from prospective studies regarding whether the magnitude of these

  16. Iatrogenic tracheal tear.

    LENUS (Irish Health Repository)

    Dias, A

    2010-10-01

    Large post intubation tracheal tears are usually detected intra-operatively due to unstable signs namely impaired ventilation and mediastinal emphysema and often require surgical management. Smaller tracheal tears are often missed during anaesthesia and recognized during the postoperative period. Conservative management should be considered in these latter cases.

  17. Anterior Segment Optical Coherence Tomography for Tear Meniscus Evaluation and its Correlation with other Tear Variables in Healthy Individuals

    Science.gov (United States)

    Dhasmana, Renu; Nagpal, Ramesh Chander

    2016-01-01

    Introduction Dry eye is one of the most common ocular diseases in this cyber era. Despite availability of multiple tests, no single test is accurate for the diagnosis of dry eye. Anterior segment optical coherence tomography is the recent tool which can be added in the armentarium of dry eye tests. Aim To evaluate tear meniscus with anterior segment optical coherence tomography and its correlation with other tear variables in normal healthy individuals. Materials and Methods In this prospective cross-sectional observational study, right eye of 203 consecutive patients were studied. All the patients were divided into three groups Group 1, 2 and 3 according to their age ≤20 years, 21-40 years and >40 years respectively. All patients underwent routine ophthalmologic examinations along with slit-lamp bio-microscopy for tear meniscus height measurement, tear film break up time, Schirmer’s I test (with anaesthesia) and optical coherence tomography imaging of inferior tear meniscus height. After focusing of the instrument with a Cross Line (CL) centered on lower tear meniscus at 6’0 clock of cornea, a 6 mm long scan was obtained. The tear meniscus height (μm) and tear meniscus area (mm2) were measured manually with help of callipers by joining upper corneo-meniscus junction to the lower lid-meniscus junction and tear meniscus height and area within the plotted line respectively and calculated by using the integrated analysis available in the custom software. Results There was significant decrease in the all tear variables with the increase in the age. According to age groups in group 1, the mean Schirmer’s (24.0±4.9)mm, tear film break up time (11.1±1.9) sec, tear meniscus height on slit lamp (600.2±167.3)mm were higher but decreased in group 2 (21.5±5.4,10.8±1.4, 597.5±186.3) and group 3 (19.8 ± 5.1, 10.2 ± 1.6, 485.6 ± 157.7) respectively. Schirmer’s test values and tear film break up time were similar in both sexes (p=0.1 and p= 0.9). Tear meniscus

  18. Hot tearing studies in AA5182

    Science.gov (United States)

    van Haaften, W. M.; Kool, W. H.; Katgerman, L.

    2002-10-01

    One of the major problems during direct chill (DC) casting is hot tearing. These tears initiate during solidification of the alloy and may run through the entire ingot. To study the hot tearing mechanism, tensile tests were carried out in semisolid state and at low strain rates, and crack propagation was studied in situ by scanning electron microscopy (SEM). These experimentally induced cracks were compared with hot tears developed in an AA5182 ingot during a casting trial in an industrial research facility. Similarities in the microstructure of the tensile test specimens and the hot tears indicate that hot tearing can be simulated by performing tensile tests at semisolid temperatures. The experimental data were compared with existing hot tearing models and it was concluded that the latter are restricted to relatively high liquid fractions because they do not take into account the existence of solid bridges in the crack.

  19. Magnetic resonance imaging findings associated with surgically proven rotator interval lesions

    Energy Technology Data Exchange (ETDEWEB)

    Vinson, Emily N.; Major, Nancy M. [Duke University Medical Center, Department of Radiology, P.O. Box 3808, Durham, NC (United States); Higgins, Laurence D. [Brigham and Women' s Hospital, Department of Orthopedic Surgery, Boston, MA (United States)

    2007-05-15

    To identify shoulder magnetic resonance imaging (MRI) findings associated with surgically proven rotator interval abnormalities. The preoperative MRI examinations of five patients with surgically proven rotator interval (RI) lesions requiring closure were retrospectively evaluated by three musculoskeletal-trained radiologists in consensus. We assessed the structures in the RI, including the coracohumeral ligament, superior glenohumeral ligament, fat tissue, biceps tendon, and capsule for variations in size and signal alteration. In addition, we noted associated findings of rotator cuff and labral pathology. Three of three of the MR arthrogram studies demonstrated extension of gadolinium to the cortex of the undersurface of the coracoid process compared with the control images, seen best on the sagittal oblique images. Four of five of the studies demonstrated subjective thickening of the coracohumeral ligament, and three of five of the studies demonstrated subjective thickening of the superior glenohumeral ligament. Five of five of the studies demonstrated a labral tear. The MRI arthrogram finding of gadolinium extending to the cortex of the undersurface of the coracoid process was noted on the studies of those patients with rotator interval lesions at surgery in this series. Noting this finding - especially in the presence of a labral tear and/or thickening of the coracohumeral ligament or superior glenohumeral ligament - may be helpful in the preoperative diagnosis of rotator interval lesions. (orig.)

  20. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    Science.gov (United States)

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  1. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  2. Tearing mode saturation with finite pressure

    International Nuclear Information System (INIS)

    Lee, J.K.

    1988-01-01

    With finite pressure, the saturation of the current-driven tearing mode is obtained in three-dimensional nonlinear resistive magnetohydrodynamic simulations for Tokamak plasmas. To effectively focus on the tearing modes, the perturbed pressure effects are excluded while the finite equilibrium pressure effects are retained. With this model, the linear growth rates of the tearing modes are found to be very insensitive to the equilibrium pressure increase. The nonlinear aspects of the tearing modes, however, are found to be very sensitive to the pressure increase in that the saturation level of the nonlinear harmonics of the tearing modes increases monotonically with the pressure rise. The increased level is associated with enhanced tearing island sizes or increased stochastic magnetic field region. (author)

  3. [The correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK].

    Science.gov (United States)

    Zhang, Luyan; Sun, Xiyu; Yu, Ye; Xiong, Yan; Cui, Yuxin; Wang, Qinmei; Hu, Liang

    2016-01-01

    To investigate the correlations between corneal sensation, tear meniscus volume, and tear film osmolarity after femtosecond laser-assisted LASIK (FS-LASIK) surgery. In this prospective clinical study, 31 patients undergoing FS-LASIK for myopia were recruited. The upper and lower tear meniscus volumes (UTMV and LTMV) were measured by customized anterior segment optical coherence tomography, tear film osmolarity was measured by a TearLab Osmolarity test device, central corneal sensation was measured by a Cochet-Bonner esthesiometer preoperatively, at 1 week, 1 and 3 months postoperatively. Repeated measures analysis of variance was used to evaluate whether the tear film osmolarity, tear meniscus volume, and corneal sensation were changed after surgery. The correlations between these variables were analyzed by the Pearson correlation analysis. The tear film osmolarity was (310.03 ± 16.48) mOsms/L preoperatively, (323.51 ± 15.92) mOsms/L at 1 week, (319.93 ± 14.27) mOsms/L at 1 month, and (314.97±12.91) mOsms/L at 3 months. The UTMV was (0.42±0.15), (0.25± 0.09), (0.30±0.11), and (0.35±0.09) μL, respectively; the LTMV was (0.60±0.21),(0.37±0.08), (0.44± 0.14), and (0.52±0.17) μL, respectively. The tear film osmolarity was significantly higher at 1 week and 1 month postoperatively compared with the baseline (P=0.001, 0.004), and reduced to the preoperative level at 3 months (P=0.573). The UTMV, LTMV, and corneal sensation values presented significant decreases at all postoperative time points (all Psensation at 1 week after surgery (r=0.356,P=0.005). There were significant correlations between the preoperative LTMV and corneal sensation at 1 week, 1 and 3 months (respectively, r=0.422, 0.366, 0.352;P=0.001, 0.004, 0.006). No significant correlations were found between the tear film osmolarity, tear meniscus volume, and corneal sensation after surgery (all P>0.05). The tear film osmolarity, tear meniscus volume, and corneal sensation became aggravated due

  4. Author Details

    African Journals Online (AJOL)

    Thompson, G. Vol 19, No 1 (2015) - Articles Two Unusual Cases of External Rotator Muscle Pathology Producing Hip Pain Abstract PDF · Vol 19, No 1 (2015) - Articles Painful Snapping Hip Owing to Bifid Iliopsoas Tendon and Concurrent Labral Tear Abstract PDF. ISSN: 2078-6778. AJOL African Journals Online. HOW TO ...

  5. Percentage Level of Tannin fur Rabbit for Leather Concerning Stitch Tearing Strength, Tearing Strength and Flexibility

    OpenAIRE

    Mustakim Mustakim; Aris Sri Widati; Lisa Purnaningtyas

    2012-01-01

    The purpose of this study was to find out the appropriate of tannin level for rabbit fur leather concerning stitch tearing strength, tearing strength, and flexibility. The result were expected to contribute good information for the society, leather craftsman, and further researchers about fur leather tanning especially rabbit fur leather with tannin concerning stitch tearing strength, tearing strength and flexibility. The material that used were 12 pieces of four months of rabbit skin. The re...

  6. Interaction of tearing modes

    International Nuclear Information System (INIS)

    Satya, Y.; Schmidt, G.

    1979-01-01

    A fully developed tearing mode modifies the magnetic field profile. The effect of this profile modification on the linear growth rate of a different tearing mode in a slab and cylindrical geometry is investigated

  7. MRI diagnosis of meniscal tears

    International Nuclear Information System (INIS)

    Kuga, Naoyuki; Oh, Toshihiro

    1996-01-01

    We studied the accuracy of magnetic resonance imaging (MRI) of the knee in fifty-six patients who were also examined arthroscopically. The accuracy, sensitivity, and specificity were 96%, 100%, and 95% for medial meniscal tears, and 91%, 67%, and 100% for lateral meniscal tears respectively. Two MRIs of the medial meniscus were false-positives. These MRI findings were both meniscocapsular separation of the medial meniscus, but the arthroscopic findings were normal. One case was an ACL injury and the other PCL and MCL injury. Hemorrhage and edema of the medial capsule caused by valgus stress at injury may look like a meniscal pseudo-tear on MRI. Five MRIs of the lateral meniscus were false-negatives. All menisci showed normal signal and shape on MRI but traumatic and stable tears of the lateral meniscus were identified arthroscopically. All were associated with ACL tears and lateral condylar bone bruise. The traumatic and stable tear of the meniscus tended to be overlooked on MRI because a meniscus without degeneration shows a normal signal. (author)

  8. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    Science.gov (United States)

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  9. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    Science.gov (United States)

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case

  10. Efficient radiologic diagnosis of pelvic and acetabular trauma

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Mildenberger, P.; Thelen, M.; Rommens, P.M.

    2000-01-01

    In spite of the widespread availability of CT scanners, conventional X-ray radiographs remain the basic imaging modality in patients with pelvic and/or acetabular trauma. However, the extent of their use will depend on local utilities (e.g., availability of CT scanners) and on the patient's clinical condition. Regarding the inaccuracy of conventional radiography in the diagnosis of injuries of the dorsal pelvic ring and of the acetabulum, computed tomography represents the most important imaging modality in the clinically stable patient. CT provides an exact staging of the extent of trauma and allows for differentiation of pelvic instabilities. CT clearly demonstrates the severity of acetabular trauma and is superior in the detection of local complicating factors, i.e., impressions fractures and (sub-)luxations of the femoral head as well as free intraarticular fragments. CT findings provide the basis for definite treatment regimens of the injured patient. By extension of the examination, all relevant organs and systems (craniospinal, cardiovascular, gastrointestinal, respiratory, genitourinary) can be imaged during one session. The speed of spiral CT scanners and their diagnostic accuracy will play a major role in the management of, especially, polytraumatized patients. The indication for angiography with the option of therapeutic embolization exists if a pelvic bleeding persists even after reposition and operative fixation of the injury. (orig.) [de

  11. Assessment of tear film osmolarity using the TearLab™ osmometer in normal dogs and dogs with keratoconjunctivitis sicca.

    Science.gov (United States)

    Sebbag, Lionel; Park, Shin Ae; Kass, Philip H; Maggs, David J; Attar, Mayssa; Murphy, Christopher J

    2017-07-01

    To evaluate repeatability and reproducibility of tear osmolarity measured using the TearLab ™ osmometer in normal dogs and to assess its diagnostic potential in dogs with keratoconjunctivitis sicca (KCS). Beagle dogs; six normal and five with KCS. Tear osmolarity and Schirmer tear test-1 (STT-1) values were obtained at various times. Normal dogs were assessed for diurnal variation and repeatability and reproducibility of measurements. Dogs with KCS were evaluated before and after 5 months' topical twice-daily therapy with 2% cyclosporine. Mean ± SD tear osmolarity (mOsm/L) was significantly higher in normal dogs (337.4 ± 16.2) than in dogs with KCS before therapy (306.2 ± 18.0; P dogs, tear osmolarity readings were stable during the daytime (P = 0.99). Repeated measurements revealed high variability and typically poor-to-moderate repeatability and reproducibility, although this was improved by taking three successive measurements at each session. Considering combined data from all dogs, a positive correlation existed between STT-1 and tear osmolarity measurements (Pearson's correlation test, P = 0.04, r = 0.62). Canine tear osmolarity as determined by TearLab ™ osmometer was variable, required multiple readings to be informative, and differed from values reported for humans. Dogs with KCS had a lower tear osmolarity than did normal dogs, and this increased following cyclosporine therapy. © 2016 American College of Veterinary Ophthalmologists.

  12. Outcomes of Hip Arthroscopy in the Older Adult: A Systematic Review of the Literature.

    Science.gov (United States)

    Griffin, Daniel W; Kinnard, Matthew J; Formby, Peter M; McCabe, Michael P; Anderson, Terrence D

    2017-07-01

    The indications for hip preservation surgery have expanded to include treatment of hip pathology in older adults. While several studies have examined the efficacy of hip arthroscopy in the setting of osteoarthritis, there has been no review of outcomes in older adults. To review the outcomes of hip arthroscopy in older adults and identify factors associated with treatment failures. Systematic review. PubMed, EMBASE, and the Cochrane Library were searched through March 2016 for studies reporting outcomes of primary hip arthroscopy in patients older than 40 years. Inclusion in the review was based on age, patient-reported outcome (PRO) measures, and duration of follow-up. Two authors screened the results and extracted data for use in this review. Standardized mean difference was calculated to estimate effect size for PRO scores within studies. Eight studies with 401 total patients undergoing hip arthroscopy for femoroacetabular impingement (FAI) or labral tears were included in this review. Seven of the 8 studies reported favorable PRO scores and significant postoperative improvement with moderate to large effect size. The included studies demonstrated a trend toward higher effect sizes with an increasing percentage of labral repair compared to isolated labral debridement. The complication rate was comparable to that of previous reports involving younger patients; however, the overall reoperation rate was 20.8%. Conversion to hip arthroplasty ranged from 0% to 30%, with an overall conversion rate of 18.5% at a mean time of 17.5 months following arthroscopy. The most common risk factors for conversion to arthroplasty were low preoperative PRO scores and advanced arthritis. Hip arthroscopy appears to be a safe and efficacious treatment for labral tears and FAI in older patients who do not have significant underlying degenerative changes. However, in this population, there is a significant proportion of patients who eventually require hip arthroplasty. Outcomes may be

  13. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Danish translation and validation of the International Skin Tear Advisory Panel Skin Tear Classification System

    DEFF Research Database (Denmark)

    Skiveren, J; Bermark, S; LeBlanc, K

    2015-01-01

    OBJECTIVE: The aim of this study was to translate, validate and establish reliability of the International Skin Tear Classification System in Danish. METHOD: Phase 1 of the project involved the translation of the International Skin Tear Advisory Panel (ISTAP) Skin Tear Classification System......) and social and health-care assistants (non-RN) from both primary health care and a Danish university hospital in Copenhagen. Thirty photographs, with equal representation of the three types of skin tears, were selected to test validity. The photographs chosen were those originally used for internal...... and external validation by the ISTAP group. The subjects were approached in their place of work and invited to participate in the study and to attend an educational session related to skin tears. RESULTS: The Danish translation of the ISTAP classification system was tested on 270 non-wound specialists...

  15. Absence or interruption of the supra-acetabular line: a subtle plain film indicator of hip pathology

    International Nuclear Information System (INIS)

    Major, N.M.; Helms, C.A.

    1996-01-01

    Objective. To show that absence or interruption of the supraacetabular line is a subtle plain film indicator of pathology in the acetabulum. Design. Nineteen hips from 17 patients with known disease processes involving the acetabulum as demonstrated by subsequent magnetic resonance imaging, bone scan or plain film follow-up were evaluated with antero-posterior (AP) plain films of the pelvis. Three additional cases were diagnosed prospectively using interruption of the supra-acetabular line as the criterion for inclusion. Fifty AP plain films of the pelvis in patients without hip pain were examined prospectively to determine normal imaging criteria. Results and conclusions. The normal supra-acetabular line measures 2-3 mm in thickness superiorly and is a thin sclerotic line in the medial aspect. In all 22 hips (with pathology) in this series, the line was interrupted or absent. Loss or interruption of the supra-acetabular line may thus be a subtle pain film indicator of a disease process involving the acetabulum. This plain film sign has not previously been reported. (orig.). With 8 figs., 1 tab

  16. Rapid Hip Osteoarthritis Development in a Patient with Anterior Acetabular Cyst with Sagittal Alignment Change

    Directory of Open Access Journals (Sweden)

    Yasuhiro Homma

    2014-01-01

    Full Text Available Rapidly destructive coxarthrosis (RDC is rare and develops unusual clinical course. Recent studies suggest multiple possible mechanisms of the development of RDC. However the exact mechanism of RDC is still not clear. The difficulty of the study on RDC is attributed to its rareness and the fact that the data before the onset of RDC is normally unavailable. In this report, we presented the patient having the radiographic data before the onset who had rapid osteoarthritis (OA development after contralateral THA, which meets the current criteria of RDC. We thought that the increased posterior tilt of the pelvis after THA reinforced the stress concentration at pre-existed anterior acetabular cyst, thereby the destruction of the cyst was occurred. As a result the rapid OA was developed. We think that there is the case of rapid osteoarthritis developing due to alternating load concentration by posterior pelvic tilt on preexisting anterior acetabular cyst such as our patient among the cases diagnosed as RDC without any identifiable etiology. The recognition of sagittal alignment changes and anterior acetabular cyst may play important role in prediction and prevention of the rapid hip osteoarthritis development similar to RDC.

  17. Linear stability of tearing modes

    International Nuclear Information System (INIS)

    Cowley, S.C.; Kulsrud, R.M.; Hahm, T.S.

    1986-05-01

    This paper examines the stability of tearing modes in a sheared slab when the width of the tearing layer is much smaller than the ion Larmor radius. The ion response is nonlocal, and the quasineutrality retains its full integal form. An expansion procedure is introduced to solve the quasineutrality equation in powers of the width of the tearing layer over the ion Larmor radius. The expansion procedure is applied to the collisionless and semi-collisional tearing modes. The first order terms in the expansion we find to be strongly stabilizing. The physics of the mode and of the stabilization is discussed. Tearing modes are observed in experiments even though the slab theory predicts stability. It is proposed that these modes grow from an equilibrium with islands at the rational surfaces. If the equilibrium islands are wider than the ion Larmor radius, the mode is unstable when Δ' is positive

  18. Acetabular osteotomy for double boarding in lateral decubitus. Anatomical bases and surgical technique

    International Nuclear Information System (INIS)

    Lazennec, J Y; Del Vecchio, R; Saillant, G

    2001-01-01

    The periacetabular osteotomies of reorientation of the eotilo have a reputation of being difficult from the technical point of view. The authors present a technique of juxta acetabular osteotomy that respects the posterior column of the acetabulo the same as the GANZ technique. The osteotomy is of simpler realization thanks to an installation that allows carrying out two simultaneous boarding. The osteotomy lines, their rectilinear and controllable in permanency through of images intensificator and they don't constitute any risk for the essential vascular contribution of the obturatriz artery and their branches. Their other interest comes represented by the possibility of correcting easily the parasitic retroversion associated to the descent of the whole eotilo, that it allows to avoid the bad positions that they affect the center of the articulation and the widths acetabular

  19. Arthroscopic treatment of chondral defects in the hip: AMIC, MACI, microfragmented adipose tissue transplantation (MATT and other options

    Directory of Open Access Journals (Sweden)

    Jannelli Eugenio

    2017-01-01

    Full Text Available Chondral lesions are currently considered in the hip as a consequence of trauma, osteonecrosis, dysplasia, labral tears, loose bodies, dislocation, previous slipped capital femoral epiphysis and Femoro-Acetabular-Impingement (FAI. The management of chondral lesions is debated and several techniques are described. The physical examination must be carefully performed, followed by radiographs and magnetic resonance imaging (MRI. Differential diagnosis with other pathologies must be considered. Debridement is indicated in patients younger than 50 years with a chondropathy of 1st or 2nd degree. Microfractures are indicated in patients younger than 50 years with a chondropathy of 3rd or 4th degree less than 2 cm2. Matrix-Induced Autologous Chondrocyte Implantation (MACI and Autologous Matrix-Induced Chondrogenesis (AMIC procedures are indicated in patients with full-thickness symptomatic 3rd–4th degree chondral defects, extended 2 cm2 or more. The AMIC procedure has the advantage of a one-step procedure and much less expense. Microfragmented adipose tissue transplantation (MATT is indicated for the treatment of delamination and 1st and 2nd degree chondral lesions, regardless of the age of the patient. Chondral defects are effective when the joint space is not compromised. When the Tonnis classification is two or greater, treatment of chondral lesions should be considered ineffective.

  20. Arthroscopic repair of large U-shaped rotator cuff tears without margin convergence versus repair of crescent- or L-shaped tears.

    Science.gov (United States)

    Park, Jin-Young; Jung, Seok Won; Jeon, Seung-Hyub; Cho, Hyoung-Weon; Choi, Jin-Ho; Oh, Kyung-Soo

    2014-01-01

    For large-sized tears of the rotator cuff, data according to the tear shape have not yet been reported for repair methodology, configuration, and subsequent integrity. The retear rate after the repair of large mobile tears, such as crescent- or L-shaped tears, is believed to be lower compared with retear rates after the repair of large U-shaped tears that are accompanied by anterior or posterior leaves of the rotator cuff. Cohort study; Level of evidence, 3. Data were collected and analyzed from 95 consecutive patients with a large-sized rotator cuff tear who underwent arthroscopic suture-bridge repair. Patients were divided into 2 groups: those having crescent- or L-shaped tears (mobile tear group, 53 patients) and those having U-shaped tears (U-shaped tear group, 42 patients). The integrity of the repaired constructs was determined by ultrasonography at 4.5, 12, and 24 months. Moreover, clinical evaluations were performed by using the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and muscle strength at intervals of 3, 6, 12, and 24 months postoperatively. On ultrasonography at 4.5, 12, and 24 months, a retear was detected in 6, 2, and 1 patients in the mobile tear group and in 5, 2, and 1 patients in the U-shaped tear group, respectively. Significant differences in retear rates were not detected between the groups overall or at each time point. Moreover, clinical scores were similar between groups, except for the presence of a temporarily higher Constant score at 12 months in the mobile tear group. With regard to shoulder strength, between-group comparisons indicated no statistically significant difference, either in abduction or external rotation, except for the presence of temporarily higher external rotation strength at 3 months in the mobile tear group. Arthroscopic repair of large-sized rotator cuff tears yielded substantial improvements in shoulder function, regardless of tear retraction, during midterm follow-up. Moreover, the

  1. A review on hot tearing of magnesium alloys

    Directory of Open Access Journals (Sweden)

    Jiangfeng Song

    2016-09-01

    Full Text Available Hot tearing is often a major casting defect in magnesium alloys and has a significant impact on the quality of their casting products. Hot tearing of magnesium alloys is a complex solidification phenomenon which is still not fully understood, it is of great importance to investigate the hot tearing behaviour of magnesium alloys. This review attempts to summarize the investigations on hot tearing of magnesium alloys over the past decades. The hot tearing criteria including recently developed Kou's criterion are summarized and compared. The numeric simulation and assessing methods of hot tearing, factors influencing hot tearing, and hot tearing susceptibility (HTS of magnesium alloys are discussed.

  2. Should total hip arthroplasty be performed acutely in the treatment of acetabular fractures in elderly or used as a salvage procedure only?

    Directory of Open Access Journals (Sweden)

    Katharine Hamlin

    2017-01-01

    Full Text Available Background: Total hip arthroplasty (THA is now an increasingly common procedure for people sustaining acetabular fractures. The incidence of acetabular fractures among the elderly population is increasing, and contemporary treatment aims to avoid the risks of prolonged incumbency associated with poor bone stock for fixation or inability to comply with limited weightbearing in this patient group. The concept of acute hip arthroplasty as a treatment for acetabular fracture is, therefore, becoming more topical and relevant. Our systematic review investigates whether THAs for acetabular fractures should be performed acutely, with a short delay, or as a late procedure for posttraumatic osteoarthritis (PTOA if it develops. Materials and Methods: Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines were followed when undertaking this systematic review. Detailed searches were performed on three different databases, using keywords, such as “acetabular fracture,” “acetabular trauma,” “total hip arthroplasty,” “hip arthroplasty,” and “hip prosthesis.” Studies from 1975 to September 2016 were included in the study. All studies included in the review were independently critically appraised by two of the authors. Results: Forty three studies were included in this review. Only two of them actually compared acute and delayed THAs for acetabular fractures with the rest focusing on one or the other. Results were comparable between acute and late THAs in terms of aseptic loosening, operative time, blood loss, Harris Hip Score, and ability to mobilize postoperatively without aid. Complication rates, however, were much higher in the acute group. Conclusion: Evidence based on this topic is scarce and therefore we have to be cautious about drawing a definitive conclusion. The findings of this systematic review do suggest, however, that acute THAs should be considered in elderly patients, where fixation is not possible, or

  3. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    Science.gov (United States)

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Revisión acetabular con conservación del componente metálico osteointegrado y cementado de un componente de poliestireno. Reporte de una serie de 40 casos. [Acetabular revision cementing a liner into a stable acetabular shell

    Directory of Open Access Journals (Sweden)

    Fernando Manuel Bidolegui

    2013-12-01

    Full Text Available In­tro­duc­ción: Un escenario cada vez más frecuente en la cirugía de revisión protésica de la cadera es hallar un cotilo no cementado fijo con una falla del componente modular de polietileno. Una completa revisión acetabular se presenta como demasiado agresiva cuando el componente metálico es salvable. Cementar un nuevo inserto de polietileno dentro del componente acetabular metálico os-teointegrado es una alternativa. Comunicamos los resultados con esta técnica, y sus indicaciones, el modo de realización y las posibles limitaciones. Materiales­y­Métodos: Entre 2001 y 2011, se cementaron 40 componentes de polietileno dentro de copas no cementadas. Se evaluó radiológicamente y clínicamente a todos los pacientes. El motivo por el que se cementó un inserto fue falla o rotura de mecanismo de captura (11 casos; 27,5%, ganar estabilidad (18 casos; 45% y falta de disponibilidad del inserto correspondiente (11 casos, 27,5%. Resultados:­ La tasa de duración del implante sin reoperación a 46 meses de seguimiento fue del 92%. Un paciente (2,4% sufrió una infección, y dos presentaron inestabilidad (4,8%. No se presentaron aflojamientos hasta el último seguimiento. El puntaje preoperatorio y posoperatorio en la escala de Harris fue de 59 y 80, respectivamente. Conclusiones: Los datos técnicos por considerar para tener éxito son: utilizar un inserto de menor tamaño que el de la copa, cementar insertos texturizados y dejar siempre como mínimo un manto de cemento uniforme de 2 mm. Nuestros resultados preliminares cementando un inserto de polietileno dentro de una copa acetabular osteointegrada parecerían justificar esta técnica de revisión en pos de prevenir la pérdida de capital óseo asociada a la necesidad de recambio de copas osteointegradas.

  5. Rotator cuff tears: correlation between geometric tear patterns on MRI and arthroscopy and pre- and postoperative clinical findings.

    Science.gov (United States)

    Sela, Yaron; Eshed, Iris; Shapira, Shachar; Oran, Ariel; Vogel, Guy; Herman, Amir; Perry Pritsch, Moshe

    2015-02-01

    Magnetic resonance imaging (MRI) is considered to be the best non-invasive procedure for the evaluation of rotator cuff (RC) tendon tears. Burkhart's classification is a geometric classification of full-thickness RC tears on MRI. To correlate MRI and arthroscopic geometric full-thickness RC tears according to the Burkhart's classification with pre- and postoperative clinical findings. Patients who underwent arthroscopic RC repair between 2006 and 2010 were retrospectively evaluated. Preoperative MRI and arthroscopic surgical reports were reviewed for tear geometry (Burkhart's) by three (1 radiologist, 2 surgeons) and two (surgeons) readers. MRIs were also evaluated for tear size and change of tear size in successive sagittal sections and for muscle mass and fatty infiltration. Clinical examinations were performed preoperatively and at least 12 months afterwards. Postoperative function questionnaires were filled in by the patients. Forty-six patients (35 men, 11 women; mean age, 57 years; range, 41-72 years) were evaluated. Tears depicted on MRIs were classified as crescent in 11 patients (24%), longitudinal in three (6.5%), massive contracted in 29 (63%), and cuff arthropathy in three (6.5%). Muscle changes were noted almost exclusively in patients with massive tears and cuff arthropathy (16/32 patients, P = 0.013). MRIs and arthroscopic geometric classifications were in close agreement. Tear type did not correlate with pre- and postoperative physical examination or with postoperative clinical questionnaires scores. Geometric RC tear characterizations on preoperative MRIs were closely associated with arthroscopic findings. Postoperative results were not affected by the geometric pattern of the tears. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. MRI of meniscal bucket-handle tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, T.H.; Hinson, G.W. [Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology

    1998-09-01

    A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)

  7. Copas de metal trabecular y aloinjertos óseos impactados en defectos acetabulares graves. Resultados a los 2-4 años. [Impacted bone allografts and trabecular metal cups in severe acetabular bone defects: 2 to 4-year results.

    Directory of Open Access Journals (Sweden)

    Martín Buttaro

    2014-06-01

    Full Text Available In­tro­duc­ción: El objetivo principal es presentar la supervivencia del componente acetabular en pacientes con defectos graves reconstruidos con copas de metal trabecular combinadas con aloinjertos óseos impactados. Como objetivo secundario, se compararon estos resultados con los previamente obtenidos por los autores en defectos de similar gravedad utilizando anillos de reconstrucción y aloinjertos óseos. Materiales­ y­ Métodos:­ Se realizaron 20 cirugías de revisión en 19 pacientes (edad promedio 65 años, controlados, de forma prospectiva, con defectos acetabulares graves tipos 3A o 3B de Paprosky, por falla mecánica o infecciosa. El puntaje funcional promedio preoperatorio fue de 6,2 puntos, según la escala de Merle D ́Aubigne. Siempre se utilizaron copas de metal trabecular y aloinjertos óseos impactados. Resultados:­ A los 30 meses de seguimiento promedio (rango 24-48 meses, la supervivencia del componente acetabular fue del 95% (IC = 75%-98%. Un paciente presentó un aflojamiento acetabular por infección profunda a las 16 semanas de la revisión y fue tratado con una artroplastia de resección. El puntaje funcional promedio, excluido el caso con aflojamiento posoperatorio, fue de 16,2 puntos. Se observó la incorporación de los aloinjertos óseos en todos los pacientes, salvo el caso con infección profunda. La comparación con nuestras series históricas reconstruidas con anillos de Kerboull o con anillos GAP arrojó resultados altamente favorables a favor de las copas de metal trabecular.  Conclusiones: Las copas de metal trabecular asociadas a aloinjertos óseos impactados ofrecen una alternativa válida en cirugía de revisión acetabular con defectos graves del capital óseo. Este método se asocia a resultados más favorables que los obtenidos antes con anillos de reconstrucción.

  8. Human bone ingrowth into a porous tantalum acetabular cup

    Directory of Open Access Journals (Sweden)

    Gregory N. Haidemenopoulos

    2017-11-01

    Full Text Available Porous Tantalum is increasingly used as a structural scaffold in orthopaedic applications. Information on the mechanisms of human bone ingrowth into trabecular metal implants is rather limited. In this work we have studied, qualitatively, human bone ingrowth into a retrieved porous tantalum monoblock acetabular cup using optical microscopy, scanning electron microscopy and energy dispersive X-ray analysis. According to the results and taking into account the short operational life (4 years of the implant, bone ingrowth on the acetabular cup took place in the first two-rows of porous tantalum cells to an estimated depth of 1.5 to 2 mm. The bone material, grown inside the first raw of cells, had almost identical composition with the attached bone on the cup surface, as verified by the same Ca:P ratio. Bone ingrowth has been a gradual process starting with Ca deposition on the tantalum struts, followed by bone formation into the tantalum cells, with gradual densification of the bone tissue into hydroxyapatite. A critical step in this process has been the attachment of bone material to the tantalum struts following the topology of the porous tantalum scaffold. These results provide insight to the human bone ingrowth process into porous tantalum implants.

  9. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty

    International Nuclear Information System (INIS)

    White, S.P.; Blom, A.W.; Lee, M.; Smith, E.J.

    2005-01-01

    To study whether there was a common pattern of clinical symptoms, signs and radiographic features for the dissociation of the polyethylene liner from an acetabular component and to postulate reasons for these features. Retrospective study of notes and radiographs of cases of revision hip arthroplasty for polyethylene liner dissociation of the cementless Harris-Galante I porous-coated acetabular component (Zimmer Inc, Warsaw, IN) at the Avon Orthopaedic Centre, Bristol, UK and St. Mary's Hospital, Bristol, UK between 1995 and 2004. Patients were contacted to confirm preoperative symptoms. Nine cases of late polyethylene liner dissociation of this prosthesis have been revised in these institutions. All patients presented with a reduction in mobility, groin pain and limp. Eight patients reported an audible noise on hip movement. In all cases, radiographs showed radiolucency medial to the femoral neck in association with an eccentrically placed femoral head showing contact with the acetabular metal shell, which we have termed the ''crescent sign.'' There is a typical clinical presentation in this study. The diagnosis can be made from a single anteroposterior pelvic radiograph without the need for previous films for comparison, or the need for arthrography. Clinicians should look specifically for the crescent sign when an eccentrically placed femoral head has been noted, in order to differentiate the more unusual diagnosis of dissociation from that of polyethylene wear. Early revision surgery can prevent damage to the femoral head and metal acetabular shell, thus reducing the complexity of revision surgery. (orig.)

  10. Difficult acetabular revision. A preliminary report.

    Science.gov (United States)

    Newport, M L; Stuchin, S A; Frankel, V H; Zuckerman, J

    1986-01-01

    Thirteen patients (14 hips) underwent revision from conventional cemented total hip arthroplasty to uncemented acetabular threaded screw-in components and cementless femoral press-fit stems by means of the Autophor, Biofit, and Ti-Thread designs. The patients suffered from all forms of primary hip disease except rheumatoid arthritis; their average age was 34 years. The average preoperative Harris hip score was 39.4; the average postoperative score was 71.2 at six months, 90.6 at one year, and 91.6 at two years. Complications included two femoral shaft fractures, one femoral nerve palsy, and one dislocation. No signs have been observed of loosening or migration as of an early (6-24 months) follow-up.

  11. Comparison of low-abundance biomarker levels in capillary-collected nonstimulated tears and washout tears of aqueous-deficient and normal patients.

    Science.gov (United States)

    Guyette, Nicole; Williams, Larezia; Tran, My-Tho; Than, Tammy; Bradley, John; Kehinde, Lucy; Edwards, Clara; Beasley, Mark; Fullard, Roderick

    2013-05-01

    Low tear volume limits the use of nonstimulated (NS) microcapillary tear collection in aqueous-deficient (AD) patients. Adding a small amount of "washout" fluid to the eye prior to tear collection is a potentially viable alternative method for abundant proteins, but is relatively untested for low-abundance biomarkers. This study determined the feasibility of the washout (WO) method as an NS alternative for low-abundance biomarkers. NS and WO biomarker profiles were compared between AD patients and non-AD controls to determine if the two methods identify the same intergroup differences. Matching NS and WO tears were collected from 48 patients by micropipette, the WO sample after instillation of 10 μL saline. Tear cytokine levels were measured by 27-Plex Bio-Rad assay. Bland-Altman analyses for each biomarker determined the agreement between tear sample types. Patients were grouped as AD or non-AD based on Schirmer score to determine if NS profile between-group differences were preserved in WO tears. Bland-Altman plots showed good biomarker level agreement between NS and WO tears for most cytokines. Five biomarkers, among those most often cited as differing in AD dry eye, differed significantly between non-AD and AD groups in both tear types. Additional biomarker differences were seen in NS tears only. The WO tear collection method is a viable alternative to NS tears for many low-abundance biomarkers and is able to replicate major NS tear differences between dry eye groups. More subtle intergroup differences are lost in WO samples because of reduced statistical power.

  12. Warm and touching tears: tearful individuals are perceived as warmer because we assume they feel moved and touched.

    Science.gov (United States)

    Zickfeld, Janis H; Schubert, Thomas W

    2018-01-31

    Recent work investigated the inter-individual functions of emotional tears in depth. In one study (Van de Ven, N., Meijs, M. H. J., & Vingerhoets, A. (2017). What emotional tears convey: Tearful individuals are seen as warmer, but also as less competent. British Journal of Social Psychology, 56(1), 146-160. Https://doi.org/10.1111/bjso.12162) tearful individuals were rated as warmer, and participants expressed more intentions to approach and help such individuals. Simultaneously, tearful individuals were rated as less competent, and participants expressed less intention to work with the depicted targets. While tearful individuals were perceived as sadder, perceived sadness mediated only the effect on competence, but not on warmth. We argue that tearful individuals might be perceived as warm because they are perceived as feeling moved and touched. We ran a pre-registered extended replication of Van de Ven et al. Results replicate the warmth and helping findings, but not the competence and work effects. The increase in warmth ratings was completely mediated by perceiving feeling moved and touched. Possible functions of feeling moved and touched with regard to emotional tears are discussed.

  13. Comparative study of lubricating properties of tear substitutes Systane® Ultra and Visine® Clear Tears

    Directory of Open Access Journals (Sweden)

    Yu. A. Pavlova

    2014-07-01

    Full Text Available Purpose: To compare tear substitutive properties of Systane® Ultra and Visine® Clear Tears in dry eye therapy.Methods: 20 patients with dry eye due to chronic blepharoconjunctivitis and 20 patients with neurotrophic dry eye following corneal refractive surgery were examined. Treatment schedule was the following: in the first 7 days, Systane® Ultra was instilled in the right eye and Visine® Clear Tears was instilled in the left eye, while from day 8 to day 30, only one medicine selected by the patient was applied. Their efficacy was measured by tear film stability and patients’ subjective sensations.Results: Norn test results improved to day 7 in patients with dry eye following corneal refractive surgery and to day 30 in patients with dry eye due to blepharoconjunctivitis regardless of eye drops used. As to patients’ comfort, Systane® Ultra is preferable to Visine® Clear Tears.Conclusion: Systane® Ultra is therapeutically similar to but preferable to Visine® Clear Tears due to good tolerability.

  14. Comparative study of lubricating properties of tear substitutes Systane® Ultra and Visine® Clear Tears

    Directory of Open Access Journals (Sweden)

    Yu. A. Pavlova

    2013-01-01

    Full Text Available Purpose: To compare tear substitutive properties of Systane® Ultra and Visine® Clear Tears in dry eye therapy.Methods: 20 patients with dry eye due to chronic blepharoconjunctivitis and 20 patients with neurotrophic dry eye following corneal refractive surgery were examined. Treatment schedule was the following: in the first 7 days, Systane® Ultra was instilled in the right eye and Visine® Clear Tears was instilled in the left eye, while from day 8 to day 30, only one medicine selected by the patient was applied. Their efficacy was measured by tear film stability and patients’ subjective sensations.Results: Norn test results improved to day 7 in patients with dry eye following corneal refractive surgery and to day 30 in patients with dry eye due to blepharoconjunctivitis regardless of eye drops used. As to patients’ comfort, Systane® Ultra is preferable to Visine® Clear Tears.Conclusion: Systane® Ultra is therapeutically similar to but preferable to Visine® Clear Tears due to good tolerability.

  15. Tear exchange and contact lenses: a review.

    Science.gov (United States)

    Muntz, Alex; Subbaraman, Lakshman N; Sorbara, Luigina; Jones, Lyndon

    2015-01-01

    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  16. MR Imaging of a Posterior Root Tear of the Medial Meniscus: Diagnostic Accuracy of Various Tear Configurations and Associated Knee Abnormalities

    International Nuclear Information System (INIS)

    Lee, Hyang Mi; Shim, Jae Chan; Kim, Jin Goo; Lee, Jae Myeong; Nam, Mee Young; Lee, Ghi Jai; Kim, Ho Kyun; Suh, Jung Ho

    2010-01-01

    To evaluate the diagnostic accuracy of the various tear configurations in a medial meniscal posterior horn root tear and assess whether any correlation exists with other associated knee abnormalities in MR imaging. A retrospective review of 146 preoperative knee MR images were performed by one experienced musculoskeletal radiologist. The tear configuration and other abnormalities were evaluated. Sensitivity, specificity, and diagnostic accuracy of each configuration in the medial meniscal posterior horn root tear were calculated. A total of 48 medial meniscal posterior horn root tears including 38 full-thickness radial, 7 partial-thickness radial, and 3 complex tears were confirmed during arthroscopy. Overall, the sensitivity, specificity, and accuracy for the detection of medial meniscal posterior horn root tear were 92% (44/48), 99% (97/98), and 97% (141/146), respectively. For each tear configuration, sensitivity, specificity, and accuracy were 82% (31/38), 97% (105/108), and 93% (136/146) for full-thickness radial tears, respectively, and 43% (3/7), 94% (131/139), and 91% (134/146) for partial-thickness radial tears, respectively. The incidence of degenerative joint disease was 85% (41/48) for the tear group, revealing a strong association. In patients with a root tear and with degenerative joint disease, the incidence of high grade cartilage defects involving the medial femoral condyle was at 80% (33/41), compared to 56% (23/41) for the presence of medial meniscal extrusion. In contrast, a similar comparison of incidence for patients with no root tears but with degenerative joint disease was at 68% (17/25) and 26% (8/31), respectively. MR imaging is very sensitive for the detection of medial meniscal root tears, but has reduced the accuracy with regard to each tear configuration. Medial meniscal root tears showed a strong association with degenerative joint disease. High grade cartilage defects of the medial femoral condyle and medial meniscal extrusions also

  17. MR Imaging of a Posterior Root Tear of the Medial Meniscus: Diagnostic Accuracy of Various Tear Configurations and Associated Knee Abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Mi; Shim, Jae Chan; Kim, Jin Goo; Lee, Jae Myeong; Nam, Mee Young; Lee, Ghi Jai; Kim, Ho Kyun; Suh, Jung Ho [Inje University College of Medicine, Seoul Paik Hospital, Seoul (Korea, Republic of)

    2010-11-15

    To evaluate the diagnostic accuracy of the various tear configurations in a medial meniscal posterior horn root tear and assess whether any correlation exists with other associated knee abnormalities in MR imaging. A retrospective review of 146 preoperative knee MR images were performed by one experienced musculoskeletal radiologist. The tear configuration and other abnormalities were evaluated. Sensitivity, specificity, and diagnostic accuracy of each configuration in the medial meniscal posterior horn root tear were calculated. A total of 48 medial meniscal posterior horn root tears including 38 full-thickness radial, 7 partial-thickness radial, and 3 complex tears were confirmed during arthroscopy. Overall, the sensitivity, specificity, and accuracy for the detection of medial meniscal posterior horn root tear were 92% (44/48), 99% (97/98), and 97% (141/146), respectively. For each tear configuration, sensitivity, specificity, and accuracy were 82% (31/38), 97% (105/108), and 93% (136/146) for full-thickness radial tears, respectively, and 43% (3/7), 94% (131/139), and 91% (134/146) for partial-thickness radial tears, respectively. The incidence of degenerative joint disease was 85% (41/48) for the tear group, revealing a strong association. In patients with a root tear and with degenerative joint disease, the incidence of high grade cartilage defects involving the medial femoral condyle was at 80% (33/41), compared to 56% (23/41) for the presence of medial meniscal extrusion. In contrast, a similar comparison of incidence for patients with no root tears but with degenerative joint disease was at 68% (17/25) and 26% (8/31), respectively. MR imaging is very sensitive for the detection of medial meniscal root tears, but has reduced the accuracy with regard to each tear configuration. Medial meniscal root tears showed a strong association with degenerative joint disease. High grade cartilage defects of the medial femoral condyle and medial meniscal extrusions also

  18. Interferometric characterization of tear film dynamics

    Science.gov (United States)

    Primeau, Brian Christopher

    The anterior refracting surface of the eye is the thin tear film that forms on the surface of the cornea. When a contact lens is on worn, the tear film covers the contact lens as it would a bare cornea, and is affected by the contact lens material properties. Tear film irregularity can cause both discomfort and vision quality degradation. Under normal conditions, the tear film is less than 10 microns thick and the thickness and topography change in the time between blinks. In order to both better understand the tear film, and to characterize how contact lenses affect tear film behavior, two interferometers were designed and built to separately measure tear film behavior in vitro and in vivo. An in vitro method of characterizing dynamic fluid layers applied to contact lenses mounted on mechanical substrates has been developed using a phase-shifting Twyman-Green interferometer. This interferometer continuously measures light reflected from the surface of the fluid layer, allowing precision analysis of the dynamic fluid layer. Movies showing this fluid layer behavior can be generated. The fluid behavior on the contact lens surface is measured, allowing quantitative analysis beyond what typical contact angle or visual inspection methods provide. The in vivo interferometer is a similar system, with additional modules included to provide capability for human testing. This tear film measurement allows analysis beyond capabilities of typical fluorescein visual inspection or videokeratometry and provides better sensitivity and resolution than shearing interferometry methods.

  19. Acetabular QCT in Total Hip Arthroplasty - a reliability study using porcine hips

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    and reliability of bone mineral density measurements (BMD) in close proximity of the acetabular cup using SECT and DECT images and 3D segmentation software. Materials and methods 22 acetabular cups (12 cemented, 10 un-cemented) were inserted in porcine hip specimens ex vivo. A femoral stem was attached to each...... difference between the double measurements in SECT was 8 mg/cm3 (p=0.64) and 2 mg/cm3 in DECT (p=0.6). In the cemented concept the differences were 33 mg/cm3 (p=0.054) and 11 mg/cm3 (p=0.014), respectively. ICC was >0.90 regardless of scan mode and cup type. In both cup types the Bland-Altman limits...... of agreement were wider in SECT (uncemented: -95 to 111; cemented: -86 to 153) compared with DECT (uncemented: -28 to 23; cemented: -21 to 44). Conclusion There were no statistically significant reliability differences between SECT and DECT, but results suggest that the agreement of DECT is better than...

  20. [Alterations in tears aqueous layer during cytostatics treatment].

    Science.gov (United States)

    Wojciechowska, Katarzyna; Wieckowska-Szakiel, Marzena; Rózalska, Barbara; Jurowski, Piotr

    2013-01-01

    The aim of the study was to evaluate tears secretion, pH and lysozyme activity in tears aqueous layer during chemotherapy in lung, breast and bowel cancer. 36 patients were enrolled to the study. Depending on the type of cancer and type of chemotherapy patients were divided into three groups. Group I (12 patients) diagnosed with non-small-cell lung cancer treated with PE schema (cisplatin, etoposide), Group II (12 patients) with breast cancer treated with FAC schema (fluorouracil, doxorubicin, cyclophosphamide), Group III (12 patients) with bowel cancer treated with FU/LV schema (fluorouracil, leucovorin). In all the patients: Schirmer's I test, pH measurements and lysozyme test were performed. Patients were examined before chemotherapy, after 2nd, 4th, 6th cycle. In group I and II lowering of tears secretion (p tears secretion (p tears film in all groups (p tears aqueous layer causing alterations of tears secretions. PH alterations depending on type of chemotherapy was observed. Lowering of lysozyme activity in tears was observed. All the deteriorations aggravate with duration of chemotherapy. Alterations of tears film parameters during chemotherapy may influence upon eye surface homeostasis and infectious complication. tears aqueous layer, Schirmer's test, lysozyme activity, tears pH.

  1. Magnetic resonance imaging of meniscal bucket-handle tears

    International Nuclear Information System (INIS)

    Dfouni, N.; Garcia, J.; Kindynis, Ph.; Bosson, D.

    1997-01-01

    To define MR signs of meniscal bucket-handle tears and evaluate the diagnostic efficiency of this technique. Retrospective study of 30 patients with a meniscal bucket-handle tear and 30 with a different type of tear, all proven by arthroscopy. The following MR signs of a bucket-handle tear were evaluated: 'separate meniscal fragment, 'double posterior cruciate ligament', 'snake sign' and 'double anterior horn'. A correct diagnosis of a bucket-handle tear was only made in 18/30 of patients. Several of the MR signs were seen in the same patient in 17 cases. A double posterior cruciate ligament was present only in cases of medial meniscus tears. The 12 menisci without these signs, and therefore not diagnosed as bucket-handle tears, were all classified as meniscal tears on the basis of signal extending to the meniscal surface. Nine of these were not displaced into the inter-condylar notch at arthroscopy. The interobserver agreement was excellent: kappa 0.88. The diagnosis of a bucket-handle meniscal tear, if it is displaced, can be made when one or more of the four MR evaluated signs are present. Other forms of meniscal tears are only exceptionally diagnosed as bucket-handle tears. (authors)

  2. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup

    Directory of Open Access Journals (Sweden)

    Guillermo Urriolagoitia-Calderón

    2008-01-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.

  3. Quadriceps Strength and Endurance After Posterior Cruciate Ligament Tears Versus Matched Group With Anterior Cruciate Ligament Tears.

    Science.gov (United States)

    Lee, Dae-Hee; Han, Seung-Beom; Lee, Jin-Hyuck; Lee, Seok-Joo; Suh, Dong-Won; Jeong, Hye-Jin

    2015-06-01

    This study was designed to compare the preoperative strengths and endurances of the quadriceps and hamstring muscles in patients with anterior cruciate ligament (ACL) versus posterior cruciate ligament (PCL) tears. Quadriceps and hamstring muscle strength and endurance were compared between 20 prospectively enrolled patients with isolated PCL tears and a retrospective, matched control group of 20 patients with isolated ACL tears. The maximal torque (60°/s) and total work (180°/s) of the quadriceps and hamstring were evaluated with an isokinetic testing device. Total work (1,094.4 ± 505.8 J v 797.5 ± 332.7 J, P = .035) and peak torque (129.9 ± 56.2 N ∙ m v 98.2 ± 37.4 N ∙ m, P = .046) of the quadriceps muscle on the involved side were higher in the PCL tear group than in the ACL tear group. However, there were no significant differences between the PCL tear group and ACL tear group in hamstring muscle strength (45.8 ± 42.3 N ∙ m and 46.0 ± 24.4 N ∙ m, respectively; P = .940) and endurance (429.3 ± 238.9 J and 382.4 ± 256.1 J, respectively; P = .574) on the involved side. The strength and endurance of the quadriceps muscle of the injured limb were greater after PCL tears than after ACL tears. However, there were no significant between-group differences in hamstring muscle strength and endurance on the involved side. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. T2* Mapping Provides Information That Is Statistically Comparable to an Arthroscopic Evaluation of Acetabular Cartilage.

    Science.gov (United States)

    Morgan, Patrick; Nissi, Mikko J; Hughes, John; Mortazavi, Shabnam; Ellerman, Jutta

    2017-07-01

    Objectives The purpose of this study was to validate T2* mapping as an objective, noninvasive method for the prediction of acetabular cartilage damage. Methods This is the second step in the validation of T2*. In a previous study, we established a quantitative predictive model for identifying and grading acetabular cartilage damage. In this study, the model was applied to a second cohort of 27 consecutive hips to validate the model. A clinical 3.0-T imaging protocol with T2* mapping was used. Acetabular regions of interest (ROI) were identified on magnetic resonance and graded using the previously established model. Each ROI was then graded in a blinded fashion by arthroscopy. Accurate surgical location of ROIs was facilitated with a 2-dimensional map projection of the acetabulum. A total of 459 ROIs were studied. Results When T2* mapping and arthroscopic assessment were compared, 82% of ROIs were within 1 Beck group (of a total 6 possible) and 32% of ROIs were classified identically. Disease prediction based on receiver operating characteristic curve analysis demonstrated a sensitivity of 0.713 and a specificity of 0.804. Model stability evaluation required no significant changes to the predictive model produced in the initial study. Conclusions These results validate that T2* mapping provides statistically comparable information regarding acetabular cartilage when compared to arthroscopy. In contrast to arthroscopy, T2* mapping is quantitative, noninvasive, and can be used in follow-up. Unlike research quantitative magnetic resonance protocols, T2* takes little time and does not require a contrast agent. This may facilitate its use in the clinical sphere.

  5. Tearing modes in toroidal geometry

    International Nuclear Information System (INIS)

    Connor, J.W.; Cowley, S.C.; Hastie, R.J.; Hender, T.C.; Hood, A.; Martin, T.J.

    1988-01-01

    The separation of the cylindrical tearing mode stability problem into a resistive resonant layer calculation and an external marginal ideal magnetohydrodynamic (MHD) calculation (Δ' calculation) is generalized to axisymmetric toroidal geometry. The general structure of this separation is analyzed and the marginal ideal MHD information (the toroidal generalization of Δ') required to discuss stability is isolated. This can then, in principle, be combined with relevant resonant layer calculations to determine tearing mode growth rates in realistic situations. Two examples are given: the first is an analytic treatment of toroidally coupled (m = 1, n = 1) and (m = 2, n = 1) tearing modes in a large aspect ratio torus; the second, a numerical treatment of the toroidal coupling of three tearing modes through finite pressure effects in a large aspect ratio torus. In addition, the use of a coupling integral approach for determining the stability of coupled tearing modes is discussed. Finally, the possibility of using initial value resistive MHD codes in realistic toroidal geometry to determine the necessary information from the ideal MHD marginal solution is discussed

  6. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    Science.gov (United States)

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  7. Rotator cuff tear: A detailed update

    Directory of Open Access Journals (Sweden)

    Vivek Pandey

    2015-01-01

    Full Text Available Rotator cuff tear has been a known entity for orthopaedic surgeons for more than two hundred years. Although the exact pathogenesis is controversial, a combination of intrinsic factors proposed by Codman and extrinsic factors theorized by Neer is likely responsible for most rotator cuff tears. Magnetic resonance imaging remains the gold standard for the diagnosis of rotator cuff tears, but the emergence of ultrasound has revolutionized the diagnostic capability. Even though mini-open rotator cuff repair is still commonly performed, and results are comparable to arthroscopic repair, all-arthroscopic repair of rotator cuff tear is now fast becoming a standard care for rotator cuff repair. Appropriate knowledge of pathology and healing pattern of cuff, strong and biological repair techniques, better suture anchors, and gradual rehabilitation of postcuff repair have led to good to excellent outcome after repair. As the healing of degenerative cuff tear remains unpredictable, the role of biological agents such as platelet-rich plasma and stem cells for postcuff repair augmentation is still under evaluation. The role of scaffolds in massive cuff tear is also being probed.

  8. Evaporation-driven instability of the precorneal tear film.

    Science.gov (United States)

    Peng, Cheng-Chun; Cerretani, Colin; Braun, Richard J; Radke, C J

    2014-04-01

    Tear-film instability is widely believed to be a signature of eye health. When an interblink is prolonged, randomly distributed ruptures occur in the tear film. "Black spots" and/or "black streaks" appear in 15 to 40 s for normal individuals. For people who suffer from dry eye, tear-film breakup time (BUT) is typically less than a few seconds. To date, however, there is no satisfactory quantitative explanation for the origin of tear rupture. Recently, it was proposed that tear-film breakup is related to locally high evaporative thinning. A spatial variation in the thickness of the tear-film lipid layer (TFLL) may lead to locally elevated evaporation and subsequent tear-film breakup. We examine the local-evaporation-driven tear-film-rupture hypothesis in a one-dimensional (1-D) model for the evolution of a thin aqueous tear film overriding the cornea subject to locally elevated evaporation at its anterior surface and osmotic water influx at its posterior surface. Evaporation rate depends on mass transfer both through the coating lipid layer and through ambient air. We establish that evaporation-driven tear-film breakup can occur under normal conditions but only for higher aqueous evaporation rates. Predicted roles of environmental conditions, such as wind speed and relative humidity, on tear-film stability agree with clinical observations. More importantly, locally elevated evaporation leads to hyperosmolar spots in the tear film and, hence, vulnerability to epithelial irritation. In addition to evaporation rate, tear-film instability depends on the strength of healing flow from the neighboring region outside the breakup region, which is determined by the surface tension at the tear-film surface and by the repulsive thin-film disjoining pressure. This study provides a physically consistent and quantitative explanation for the formation of black streaks and spots in the human tear film during an interblink. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Use of iPhone technology in improving acetabular component position in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Xiau Wei Tay, MBBS

    2017-09-01

    Full Text Available Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1 free hand, (2 alignment jig (Sputnik, and (3 iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section. Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant (F[2,51] = 4.17, P = .02 in the “untrained group”. There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.

  10. Lumbosacral plexopathies associated with acetabular fracture

    Directory of Open Access Journals (Sweden)

    Patpiya Sirasaporn

    2017-01-01

    Full Text Available Lumbosacral plexopathies are of considerably less epidemiologic common prevalence than brachial plexus. The most common form of trauma resulting in lesions affecting the lumbosacral plexus is injuries to sacroiliac region. The symptoms which are caused by compressing lumbosacral plexus are sensory disturbance and weakness in an affected leg. The author reports a case of a 65-year-old male with a history of right acetabular fracture status post open reduction and internal fixation by plate and screw who complained weakness and numbness in the right leg. Four months later, he still had difficulty in walking and felt paresthesia at the right lateral thigh and entire of the right foot. His further investigation which was electrodiagnostic study was diagnosed as right lumbosacral plexopathies.

  11. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  12. Thermal effects on tearing mode saturation

    International Nuclear Information System (INIS)

    Kim, J.S.; Chu, M.S.; Greene, J.M.

    1988-01-01

    The effect of geometry on tearing modes, saturated states of tearing modes, and the thermal effect on tearing modes are presented. The configuration of current and magnetic fields are quite different in slabs and in Tokamaks. However, for any magnetic island regardless of geometry and heating conditions, at island saturation the product of resistivity and current is the same at magnetic O and X lines. The temperature perturbation effect on the nonlinear development of tearing modes is investigated. Thermal conduction along the field lines is much faster than that in the perpendicular direction, and thus the temperature profile follows the island structure. Utilizing Spitzer's conductivity relation, the temperature perturbation is modelled as helical components of resistivity. For a usual tearing mode unstable Tokamak, where shear is positive, the islands continue to grow to a larger size when the islands are cooled. When they are heated, the island sizes are reduced. The temperature perturbation can induce islands even for equilibria stable with respect to tearing modes. Again, the islands appear when cooling takes place. The equilibria with the cooled islands show enhanced field line stochasticity, thus enhanced heat transport. Therefore, thermal instability can be directly related to pressure disruptions. (author)

  13. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  14. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  15. Tear and decohesion of bovine pericardial tissue.

    Science.gov (United States)

    Tobaruela, Almudena; Elices, Manuel; Bourges, Jean Yves; Rojo, Francisco Javier; Atienza, José Miguel; Guinea, Gustavo

    2016-10-01

    The aim of this study was to evaluate quantitatively the fracture-by tear and delamination-of bovine pericardium tissues which are usually employed for the manufacture of bioprosthetic valves. A large number of samples (77) were tested in root-to-apex and circumferential directions, according to a standardised tear test (ASTM D 1938). Before performing the tear test, some samples were subjected to 1000 cycles of fatigue to a maximum stress of 3MPa. Fracture toughness of tearing and delamination were computed by following a simple fracture model. The study showed significantly lower values of delamination toughness compared with tear delamination. Moreover, tear forces were different in each test direction, revealing a clear orthotropic behaviour. All these results, as well as the testing procedure, could be of value for future research in the physiological function of pericardium tissues and clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Evaluating tear clearance rate with optical coherence tomography.

    Science.gov (United States)

    Garaszczuk, Izabela K; Mousavi, Maryam; Cervino Exposito, Alejandro; Bartuzel, Maciej M; Montes-Micó, Robert; Iskander, D Robert

    2018-02-01

    To assess the early-phase of tear clearance rate (TCR) with anterior segment optical coherence tomography (OCT) and to determine the association between TCR and other clinical measures of the tear film in a group of young subjects with different levels of tear film quality. TCR was classified as the percentage decrease of subject's inferior tear meniscus height 30s after instillation of 5μl 0.9% saline solution. Fifty subjects (32F and 18M) aged (mean±standard deviation) 25.5±4.3 years volunteered for the study. It consisted of a review of medical history, Ocular Surface Disease Index (OSDI) questionnaire, tear film osmolarity measurements, slit lamp examination and TCR estimation based on dynamic measurements of the lower tear meniscus with OCT. Estimates of TCR were contrasted against subject age and tear film measures commonly used for dry eye diagnosis, which includes OSDI score, fluorescein tear film break-up time (FBUT), tear meniscus height (TMH), blinking frequency, tear film osmolarity and corneal staining. The group mean TCR was 29±13% and 36±19% respectively after 30 and 60s margin after saline solution instillation. Statistically significant correlations were found between TCR and FBUT (r 2 =0.319, placrimal functional unit. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  17. Tearing mode instability due to anomalous resistivity

    International Nuclear Information System (INIS)

    Furuya, Atsushi; Itoh, Sanae I.; Yagi, Masatoshi

    2000-01-01

    Tearing mode instability in the presence of microscopic truculence is investigates. The effects of microscopic turbulence on tearing mode are taken as drags which are calculated by one-point renormalization method and mean-field approximation. These effects are reduced to effective diffusivities in reduced MHD equations. Using these equations, the stability analyses of the tearing mode are performed. It is shown that a finite amplitude of fluctuation enhances the growth rate of tearing mode. For very high values of turbulent diffusivities, marginally stable state exists. The effects of each turbulent diffusivity on mode stability are examined near marginal stability boundary. Parameter dependence of the resistive ballooning mode turbulence on tearing mode is analyzed as an example. (author)

  18. Two-Tunnel Transtibial Repair of Radial Meniscus Tears Produces Comparable Results to Inside-Out Repair of Vertical Meniscus Tears.

    Science.gov (United States)

    Cinque, Mark E; Geeslin, Andrew G; Chahla, Jorge; Dornan, Grant J; LaPrade, Robert F

    2017-08-01

    Radial meniscus tears disrupt the circumferential fibers and thereby compromise meniscus integrity. Historically, radial tears were often treated with meniscectomy because of an incomplete understanding of the biomechanical consequences of these tears, limited information regarding the biomechanical performance of repair, and the technical difficulty associated with repair. There is a paucity of studies on the outcomes of the repair of radial meniscus tears. Purpose/Hypothesis: The purpose was to determine the outcomes of 2-tunnel transtibial repair of radial meniscus tears and compare these results to the outcomes of patients who underwent the repair of vertical meniscus tears with a minimum of 2-year follow-up. The hypothesis was that radial and vertical meniscus tear repair outcomes were comparable. Cohort study; Level of evidence, 3. Patients who underwent 2-tunnel transtibial pullout repair for a radial meniscus tear were included in this study and compared with patients who underwent inside-out repair for a vertical meniscus tear. Subjective questionnaires were administered preoperatively and at a minimum of 2-year follow-up, including the Lysholm score, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Short Form-12 (SF-12) physical component summary (PCS), the Tegner activity scale, and patient satisfaction. Analysis of covariance was used to compare postoperative outcome scores between the meniscus repair groups while accounting for baseline scores. Adjusted mean effects relative to the radial repair group were reported with 95% CIs. Twenty-seven patients who underwent 2-tunnel transtibial pullout repair for radial meniscus tears and 33 patients who underwent inside-out repair for vertical meniscus tears were available for follow-up at a mean of 3.5 years (range, 2.0-5.4 years). No preoperative outcome score significantly differed between the groups. There were no significant group differences for any of the 2-year

  19. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  20. Importance of preoperative imaging in acetabular revision surgery - a case report.

    Science.gov (United States)

    Schmitz, Hc; Egidy, Cc; Al-Khateeb, H; Cárdenas, G; Gehrke, T; Kendoff, D

    2012-01-01

    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures.In our case, a major bony defect of the acetabulum was a result of the protrusion of an implanted reinforcement ring. A preoperative, contrast-enhanced CT scan showed that the urethra was in close proximity to the hook of the reinforcement ring.The preoperative imaging aided in identifying and understanding the potential complications that could occur intraoperatively. Additionally, it delineated the intact anatomic structures prior to surgery, which could have medico-legal implications.The importance of preoperative imaging and the existing literature is discussed within this case description.

  1. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures.

    Science.gov (United States)

    Gupta, Sandeep; Singh, Jagdeep; Virk, Jagandeep Singh

    2017-06-01

    Complete visualization of certain acetabular fractures of posterior wall or column with cranial extension involving superior dome from standard surgical exposures is a challenge. Osteotomy of the greater trochanter has been used to enhance fracture visualization, especially the dome, in posterior and lateral exposures of the acetabulum. It also decreases the need for excessive muscle retraction. The purpose of the study was to investigate the outcome associated with trochanteric flip osteotomy in the management of certain acetabulum fractures. From January 2011 to December 2013, 25 displaced acetabular fractures were treated by open reduction and internal fixation. The fractures were managed using a Kocher-Langenbeck approach along with trochanteric flip osteotomy. At 3rd, 6th and 24th month follow-up, all patients had radiographic examination and underwent a final clinical evaluation based on the modified Merle d'Aubigne and Postel score. The strength of the abductors was assessed according to the Medical Research Council (MRC) grading system. Congruent reduction was achieved in all patients and all osteotomies healed within an average period of 3.8 months. All our patients were allowed full weight bearing at the end of 3 months and with no abductor lurch at the end of 6 months follow-up. There were no cases of avascular necrosis of femoral head. None of the patients had any neurovascular complication or infection by the end of the follow-up period. Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  2. Chemosignalling effects of human tears revisited: Does exposure to female tears decrease males' perception of female sexual attractiveness?

    Science.gov (United States)

    Gračanin, Asmir; van Assen, Marcel A L M; Omrčen, Višnja; Koraj, Ivana; Vingerhoets, Ad J J M

    2017-01-01

    Gelstein et al. reported the results of three experiments suggesting a dampening influence of inhalation of female emotional tears on males' arousal and perception of female sexual attractiveness, specifically in non-sexual situations. This prompted the hypothesis that crying exerts its influence on others not only via the auditory and visual mode but also via chemosignals. In three studies, we attempted to replicate and extend Gelstein et al.'s findings by including an additional condition with irritant tears, by using pictures of sexually attractive women, and by testing related hypotheses on the pro-social effects of exposure to tears. All three studies, separately or combined in a meta-analysis, failed to replicate the original inhibitory effects of tears. In addition, sniffing tears did not affect measures of connectedness, aggression and pro-social behaviour. It is concluded that the effects of female tears on male arousal and perception of female sexual attractiveness, if any, are very weak at best. Rather, it seems that crying exerts its strong inter-personal effects through the visual and auditory sensory channels.

  3. Effectiveness of Combined Tear Film Therapy in Patients with Evaporative Dry Eye with Short Tear Film Breakup Time.

    Science.gov (United States)

    Kim, Yung Hui; Kang, Yeon Soo; Lee, Hyo Seok; Choi, Won; You, In Cheon; Yoon, Kyung Chul

    2017-10-01

    The aim of this study was to evaluate the effectiveness of combined tear film therapy targeted to aqueous, mucin, and lipid layers in patients with refractory evaporative dry eye (EDE) with short tear film breakup time (TBUT). The patients who had EDE with short TBUT and severe symptoms refractory to artificial tears were treated with hyaluronic acid (HA) 0.15% and diquafosol tetrasodium (DQS) 3% (Group 1), HA and carbomer-based lipid-containing eyedrops (Liposic EDO Gel, LPO) (Group 2), or HA, DQS, and LPO (Group 3). Ocular Surface Disease Index (OSDI) score, visual analog scale (VAS) symptom score, TBUT, Schirmer score, and corneal and conjunctival staining scores were evaluated, and noninvasive tear film breakup time (NIBUT) and tear meniscus height were measured using Keratograph ® 5 M before and 1 and 3 months after treatment. OSDI scores, VAS scores, TBUT, and NIBUT were improved at 1 and 3 months after treatment in all groups (all P film layers was most effective in improving ocular symptoms and tear film quality.

  4. The development and nature of femoral head cam lesions following acetabular fractures.

    Science.gov (United States)

    Berber, Onur; Foote, Julian; Sabharwal, Sanjeeve; Datta, Gorav; Bircher, Martin D

    2014-01-01

    The aim of acetabular fracture fixation is to restore joint congruity with restoration of the articular surface. Poor outcomes are seen where this has not been achieved. Letournel reported a collarette osteophyte seen postoperatively in a proportion of patients, which he suggested was an early precursor to the development of osteoarthritis. This is a retrospective study of patients treated at a tertiary referral unit who developed this lesion. The triangular index was measured in 48 of these patients and then correlated with their clinical findings, Oxford Hip Score and the presence of osteoarthritis. Length of follow-up, fracture classification, and joint congruency were also recorded. Results showed a statistically significant relationship between cam lesion size and the development of osteoarthritis (P = 0.008), cam lesion size and length of follow-up (P = 0.01), and between groin pain and postoperative joint congruency (LR = 0.035). These findings suggest that the appearance of a cam lesion is a poor long-term prognostic marker for the development of osteoarthritis in patients with an acetabular fracture.

  5. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  6. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  7. Tear ferning test in healthy dogs.

    Science.gov (United States)

    Oriá, Arianne P; Raposo, Ana Claudia S; Araújo, Nayone L L C; Lima, Felipe B; Masmali, Ali M

    2017-11-07

    To evaluate and compare three tear sampling methods using two grading scales for administering the tear ferning test (TFT) to healthy dogs. In total, 90 dogs (180 eyes) were subjected to tear sampling using millimetered strips, reused after the Schirmer tear test (STT) (Schirmer group, SG). Then, the dogs were subdivided into three groups according to sampling approach: micropipette (MPG), microcapillary (MCG), and Schirmer sample 2 (S2G). The collected tears were dried on a clean microscope glass slide at room temperature and humidity. The ferning patterns were observed under a polarized light microscope and classified according to the Rolando and Masmali grading scales. Although all three methods were feasible, the STT was easier to perform in clinical settings. Type I and Grade 1 were the most commonly observed (64.17% and 61.7%, respectively) regardless of collection method. There was no significant difference between the STT median values and the TFT classifications. The TFT is appropriate for dogs and can be performed using the three suggested sampling methods, with a higher frequency of Type I and Grade 1. Thus, it is possible to use both grading scales in the classification of tear ferning in dogs. © 2017 American College of Veterinary Ophthalmologists.

  8. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  9. Role of MRI in predicting meniscal tear reparability

    Energy Technology Data Exchange (ETDEWEB)

    Felisaz, Paolo Florent [Universita degli Studi di Pavia, Pavia (Italy); Fondazione IRCCS Policlinico San Matteo, Istituto di Radiologia, Pavia (Italy); Alessandrino, Francesco; Perelli, Simone [Universita degli Studi di Pavia, Pavia (Italy); Zanon, Giacomo; Benazzo, Francesco [Fondazione IRCCS Policlinico San Matteo, Clinica Ortopedica e Traumatologica, Pavia (Italy); Calliada, Fabrizio; Sammarchi, Luigi [Fondazione IRCCS Policlinico San Matteo Radiologia, Diagnostica per Immagini-Istituto di Radiologia, Pavia (Italy)

    2017-10-15

    To elucidate the role of MRI in predicting meniscal tear reparability according to tear type and location in relation to vascular zones. In this retrospective study, two readers evaluated 79 pre-surgical MRIs of meniscal tears arthroscopically treated with meniscectomy or meniscal repair. Tears were classified according to type into vertical, horizontal, radial, complex, flaps and bucket handle and were considered reparable if the distance measured from the tear to the menisco-capsular junction was less than or equal to 5 mm. Predictions were compared with the surgical procedure performed in arthroscopy. We assessed the diagnostic performance of MRI, agreement between MRI and arthroscopy, and interrater agreement. Then, we conducted an ROC analysis on the distances measured by the first reader and built a multivariate logistic regression model. MRI had a sensitivity, specificity, PPV, NPV and accuracy, respectively, of 85%, 79%, 86%, 76% and 83% in predicting meniscal tear reparability. Correct predictions for the specific tear pattern were 76% for vertical, 84% for horizontal, 88% for radial, 86% for complex, 84% for flaps and 86% for bucket handle. Agreement between the two readers' predictions and arthroscopy was good (k = 0.65 and 0.61, respectively). Inter-rater agreement was almost excellent (k = 0.79). The ROC analysis revealed sensitivity and specificity of 73% and 83% with a cutoff value of <4 mm (p < 0.001). Anterior cruciate ligament injury and medial meniscal tear increased the likelihood of meniscal tear reparability. MRI can be a reliable and accurate tool to predict the reparability of meniscal tears, with higher prediction rates for bucket-handle tears. (orig.)

  10. Abordagem cirúrgica inédita para denervação acetabular em cães A new surgical approach to acetabular denervation in dogs

    Directory of Open Access Journals (Sweden)

    Cássio R.A. Ferrigno

    2007-02-01

    Full Text Available Este artigo tem por objetivo demonstrar nova abordagem cirúrgica para denervação seletiva das fibras sensitivas do periósteo acetabular, para tratamento da displasia coxo femoral em cães, conduzidas em 189 articulações. Para tanto, é descrita abordagem da região cranial e dorso-lateral do acetábulo de cães por incisão em forma de meia lua de aproximadamente de três centímetros de extensão, iniciando trocânter maior do fêmur e em direção ao corpo do ílio. Após rebatimento dorsal do músculo glúteo médio, secciona-se parcialmente a inserção do m. glúteo profundo para acesso às regiões citadas. Com auxílio de cureta foi removido, em todos os pacientes, periósteo na margem acetabular cranial e dorso lateral, até a exposição da cortical óssea. Em todos os animais foi possível a abordagem, tanto da face cranial como também acesso para a curetagem da face dorsal do acetábulo, com a técnica descrita, com incisão de pele de aproximadamente 3,2cm. A curetagem da porção cranial do acetábulo foi, em todos os casos realizados, sem visualização do osso, mas de fácil confecção e sem intercorrências de lesão de nervos ou músculos. Em todas as abordagens foi possível visualizar a cápsula articular da articulação coxo femoral, e em nenhum dos animais esta estrutura foi incisada por erro de técnica. Conclui-se que a abordagem cirúrgica descrita no presente trabalho é factível para este tipo de procedimento cirúrgico em cães, promovendo acesso adequado, com mínima invasão e sem complicações de qualquer natureza.The purpose of this study is to demonstrate a new surgical approach for the selective denervation of the sensitive fibers of the acetabular periosteum, for the treatment of hip dysplasia in dogs, conducted in 189 joints.The surgical approach of the cranial and dorso-lateral regions of the acetabular joint in dogs, by moon-shaped incision of approximately 3cm in extension, starting from the

  11. Antioxidant content and ultraviolet absorption characteristics of human tears.

    Science.gov (United States)

    Choy, Camus Kar Man; Cho, Pauline; Benzie, Iris F F

    2011-04-01

    Dry eye syndrome is a common age-related disorder, and decreased antioxidant/ultraviolet (UV) radiation protection in tears may be part of the cause. This study aimed to compare the tear antioxidant content and flow rate in young and older adults. The total antioxidant content and UV absorbing properties of various commercially available ophthalmic solutions used to alleviate dry eye symptoms were also examined. Minimally stimulated tears were collected from 120 healthy Chinese adults with no ocular pathology. Two age groups were studied: 19 to 29 years (n = 58) and 50 to 75 years (n = 62). Tear samples from each subject and 13 ophthalmic solutions were analyzed for total antioxidant content (as the Ferric Reducing/Antioxidant Power value). Tear flow rates were estimated from time taken to collect a fixed volume of tear fluid. UV absorbance spectra of pooled fresh reflex tear fluid and the ophthalmic solutions were determined. Results showed that the antioxidant content of minimally stimulated tears from older subjects (398 ± 160 μmol/l) was not significantly lower than that of younger subjects (348 ± 159 μmol/l; p = 0.0915). However, there was a significant difference in the tear flow rates between the two groups (p tears. The effect of low flow rate on the dynamic antioxidant supply to the corneal surface indicates that older subjects have poorer overall defense against photooxidative and other oxidative processes. This could predispose older persons to corneal stress and development of dry eye syndrome. The commercially available artificial tears tested lack both the antioxidant content and UV absorbing characteristics of natural tears. Artificial tears formulations that help restore natural antioxidant and UV absorbing properties to the tear film of the aging eye may help prevent or improve dry eye symptoms and promote ocular health.

  12. Single-stage Acetabular Revision During Two-stage THA Revision for Infection is Effective in Selected Patients.

    Science.gov (United States)

    Fink, Bernd; Schlumberger, Michael; Oremek, Damian

    2017-08-01

    The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All

  13. A study of re-tear cases after ARCR

    International Nuclear Information System (INIS)

    Ishida, Yasuyuki; Chosa, Etsuo; Yano, Hiroaki

    2011-01-01

    Recently, good clinical outcomes of arthroscopic rotator cuff repair (ARCR) are reported, but the re-tear rate of massive and large rotator cuff tears is still high. The purpose of this study is to review the clinical outcome and postoperative cuff integrity of ARCR in our hospital. We evaluated 80 shoulders (61 males, 19 females), whose age rauged from 30 to 78 (average: 61.8 years old). The size of tears were 8 small, 22 medium, 36 large, and 14 massive. We evaluated the pre-and postoperative Japanese Orthopedic Association (JOA) scored, and MRI findings 12 months postoperatively. We evaluated the cuff integrity and fatty degeneration of the ruptured cuff by Goutallier's classification. Postoperative MRI findings showed complete repair in 56 shoulders (70%) and re-tear in 24 shoulders (30%). Postoperative JOA score was poor in cases with large re-tears. Retear rates were high in large and massive tears, tears with advanced fatty degeneration, and subscapularis tears. As this operation is not a replacement procedure, the quality of the ruptured rotator cuff is important. Further discussion on the operative indication and method is necessary. (author)

  14. Changes of tear film after trabeculectomy in glaucoma

    Directory of Open Access Journals (Sweden)

    Xue-Jun Li

    2015-07-01

    Full Text Available AIM: To learn the changes of the tear film before and after the trabeculectomy of glaucoma and explore the incidence of dry eye and the prevention and control measures.METHODS: The 36 patients(60 eyesof glaucoma were examined in detail before 3d of trabeculectomy and after the surgery at 3, 7, 14 and 30d. The examinations include lower eyelid central river of tears, break-up time(BUT, Schirmer Ⅰ test(SⅠtand staining scores of corneal fluorescein under slit lamp microscope.RESULTS:The tear meniscus height of central lower eyelid was increased and the tear film BUT was shortened at the same time, the scores of SⅠt was reduced and corneal fluorescein staining score was increased at postoperative 3 and 7d compared with that of preoperation. The tear meniscus height of central lower eyelid, tear film BUT and SIt and score of corneal fluorescein staining began to recover in most of the affected eyes after surgery 14d. At 30d after surgery, 22% of patients tear film failed to recover to the preoperative level; dry eye occured in 18% preoperative eyes with normal tear film.CONCLUSION:Trabeculectomy of glaucoma may affect the stability of the tear film and some patients showeing obvious dry eye and should be intervened and treatmented timely.

  15. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study.

    Science.gov (United States)

    Gurgel, Henrique M C; Croci, Alberto T; Cabrita, Henrique A B A; Vicente, José Ricardo N; Leonhardt, Marcos C; Rodrigues, João Carlos

    2014-01-01

    In a study of the acetabular component in total hip arthroplasty, 20 hips were operated on using imageless navigation and 20 hips were operated on using the conventional method. The correct position of the acetabular component was evaluated with computed tomography, measuring the operative anteversion and the operative inclination and determining the cases inside Lewinnek's safe zone. The results were similar in all the analyses: a mean anteversion of 17.4° in the navigated group and 14.5° in the control group (P=.215); a mean inclination of 41.7° and 42.2° (P=.633); a mean deviation from the desired anteversion (15°) of 5.5° and 6.6° (P=.429); a mean deviation from the desired inclination of 3° and 3.2° (P=.783); and location inside the safe zone of 90% and 80% (P=.661). The acetabular component position's tomography analyses were similar whether using the imageless navigation or performing it conventionally. Published by Elsevier Inc.

  16. Impact of environmental adaptation on tear film assessments.

    Science.gov (United States)

    Fagehi, R

    2018-03-01

    The purpose of this study was to investigate the effect of ocular environmental adaptation on clinical tear film assessment. Thirty subjects (male, mean age 23±2.5) participated in this study. A number of clinical tear film tests were applied, including: fluorescein tear break-up time (FTBUT), Schirmer test and tear prism height test (TPH). The tear physiology of each subject was evaluated twice, once immediately when they arrived from the external environment, and then after 30minutes adaptation in the exam room environment. The mean values were: Schirmer test A (22.1±2.99), Schirmer test B (24.2±2.63), FTBUT A (8.00±1.94), FTBUT B (9.13±2.04), TPH A (0.179±0.026) and TPH B* (0.187±0.023). Statistical testing using Wilcoxon-signed rank test showed a significant difference between the Schirmer test results measured at the different times (P=0.008). Also, the FTBUT and tear prism height test results showed significant differences between the two evaluation times, (P=0.001, 0.011, respectively) (A: tear assessed when the subject comes from the outside environment, B: tear film assessed after 30min adaptation in the clinical environment). This study showed a significant difference between the tear film test results evaluated when the subjects were assessed immediately from the outside environment and after an adaptation time in the clinic environment. Practitioners must consider the effect of differences between external and clinical environment adaptation on clinical tear film physiology. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  17. Clinical outcome of pedestal cup endoprosthetic reconstruction after resection of a peri-acetabular tumour

    NARCIS (Netherlands)

    Bus, M. P. A.; Boerhout, E. J.; Bramer, J. A. M.; Dijkstra, P. D. S.

    2014-01-01

    Peri-acetabular tumour resections and their subsequent reconstruction are among the most challenging procedures in orthopaedic oncology. Despite the fact that a number of different pelvic endoprostheses have been introduced, rates of complication remain high and long-term results are mostly lacking.

  18. MR imaging-based diagnosis and classification of meniscal tears.

    Science.gov (United States)

    Nguyen, Jie C; De Smet, Arthur A; Graf, Ben K; Rosas, Humberto G

    2014-01-01

    Magnetic resonance (MR) imaging is currently the modality of choice for detecting meniscal injuries and planning subsequent treatment. A thorough understanding of the imaging protocols, normal meniscal anatomy, surrounding anatomic structures, and anatomic variants and pitfalls is critical to ensure diagnostic accuracy and prevent unnecessary surgery. High-spatial-resolution imaging of the meniscus can be performed using fast spin-echo and three-dimensional MR imaging sequences. Normal anatomic structures that can mimic a tear include the meniscal ligament, meniscofemoral ligaments, popliteomeniscal fascicles, and meniscomeniscal ligament. Anatomic variants and pitfalls that can mimic a tear include discoid meniscus, meniscal flounce, a meniscal ossicle, and chondrocalcinosis. When a meniscal tear is identified, accurate description and classification of the tear pattern can guide the referring clinician in patient education and surgical planning. For example, longitudinal tears are often amenable to repair, whereas horizontal and radial tears may require partial meniscectomy. Tear patterns include horizontal, longitudinal, radial, root, complex, displaced, and bucket-handle tears. Occasionally, meniscal tears can be difficult to detect at imaging; however, secondary indirect signs, such as a parameniscal cyst, meniscal extrusion, or linear subchondral bone marrow edema, should increase the radiologist's suspicion for an underlying tear. Awareness of common diagnostic errors can ensure accurate diagnosis of meniscal tears. Online supplemental material is available for this article. ©RSNA, 2014.

  19. Multicenter Analysis of Midterm Clinical Outcomes of Arthroscopic Labral Repair in the Hip: Minimum 5-Year Follow-up.

    Science.gov (United States)

    Hevesi, Mario; Krych, Aaron J; Johnson, Nick R; Redmond, John M; Hartigan, David E; Levy, Bruce A; Domb, Benjamin G

    2018-02-01

    The technique of hip arthroscopic surgery is advancing and becoming more commonly performed. However, most current reported results are limited to short-term follow-up, and therefore, the durability of the procedure is largely unknown. To perform a multicenter analysis of mid-term clinical outcomes of arthroscopic hip labral repair and determine the risk factors for patient outcomes. Cohort study; Level of evidence, 3. Prospectively collected data of primary hip arthroscopic labral repair performed at 4 high-volume centers between 2008 and 2011 were reviewed retrospectively. Patients were assessed preoperatively and postoperatively with the visual analog scale (VAS), modified Harris Hip Score (mHHS), and Hip Outcome Score-Sports-Specific Subscale (HOS-SSS) at a minimum of 5 years' follow-up. Factors including age, body mass index (BMI), Tönnis grade, and cartilage grade were analyzed in relation to outcome scores, and revision rates were determined. Failure was defined as subsequent ipsilateral hip surgery, including revision arthroscopic surgery and open hip surgery. A total of 303 patients (101 male, 202 female) with a mean age of 32.0 years (range, 10.7-58.9 years) were followed for a mean of 5.7 years (range, 5.0-7.9 years). Patients achieved mean improvements in VAS of 3.5 points, mHHS of 20.1 points, and HOS-SSS of 29.3 points. Thirty-seven patients (12.2%) underwent revision arthroscopic surgery, and 12 (4.0%) underwent periacetabular osteotomy, resurfacing, or total hip arthroplasty during the study period. Patients with a BMI >30 kg/m 2 had a mean mHHS score 9.5 points lower and a mean HOS-SSS score 15.9 points lower than those with a BMI ≤30 kg/m 2 ( P 35 years at surgery had a mean mHHS score 4.5 points lower and a HOS-SSS score 6.7 points lower than those aged ≤35 years ( P = .03). Patients with Tönnis grade 2 radiographs demonstrated a 12.5-point worse mHHS score ( P = .02) and a 23.0-point worse HOS-SSS score ( P SSS scores after arthroscopic

  20. Influence of preoperative artificial tears on tear film after phacoemulsification on dry eye of diabetes patients

    Directory of Open Access Journals (Sweden)

    Rui Su

    2015-05-01

    Full Text Available AIM: To discuss the artificial tears on the tear film of diabetic patients with dry eye preoperatively, and the influence on the tear film's fuctional after phacoemulsification.METHODS: Fifty-four diabetic patients with dry eye(60 eyeswere followed up before phacoemulsification. Preoperatively, group A(30 eyes in 28 caseswas treated with Hydroxyl Indican eye drops and group B(30 eyes in 26 caseswas not treated. Postoperatively, both group A and B were treated with Tobramycin Dexamethasone eye drops, Oprah Winfrey Ibuprofen eye drops and Hydroxyl Indican eye drops. Dry eye symptoms, break up time(BUT, Schirmer Ⅰ test(S Ⅰ t, fluorescein stain test(FIwere measured at 3d preoperatively, and 1, 7, 30, 90d postoperatively.RESULTS: At 3d preoperatively, there was no statistical differences between the two groups for dry eye symptoms, BUT, SⅠt, FI(P>0.05. At 1 and 7d postoperatively, there were significant statistical differents between the two groups for dry eye symptoms(PPP>0.05.CONCLUSION: Using artificial tears before phacoemulsification can improve symptoms of the diabetic patients with dry eye and accelerate the recovery of the tear film.

  1. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  2. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  3. Diagnostic value of self-reported mechanical symptoms for diagnosing large meniscal tears in patients aged 40 years or older with meniscal tears

    DEFF Research Database (Denmark)

    Pihl, Kenneth; Englund, Martin; Lohmander, Stefan

    2017-01-01

    Purpose: Meniscal tears, which are longitudinal-vertical tears (e.g. bucket-handle tears) and/or involve all three meniscal sub regions (anterior horn, body and posterior horn), are typically large and assumed to cause patient perceived mechanical knee symptoms (knee grinding or clicking and knee...... catching or locking). However, whether the presence of such mechanical symptoms is useful for diagnosing these forms of meniscus tears is unknown. Therefore, we investigated the diagnostic values of having mechanical symptoms in diagnosing a bucket-handle tear and/or a tear involving all three meniscal sub...... regions in middle-aged and older patients undergoing arthroscopic meniscal surgery. Methods: This study is a secondary analysis of Pihl et al. OARSI 2017. The study included patients aged 40 years or older undergoing surgery for a meniscal tear from Knee Arthroscopy Cohort Southern Denmark (KACS...

  4. Computer-aided designed, three dimensional-printed hemipelvic prosthesis for peri-acetabular malignant bone tumour.

    Science.gov (United States)

    Wang, Baichuan; Hao, Yongqiang; Pu, Feifei; Jiang, Wenbo; Shao, Zengwu

    2018-03-01

    Prosthetic reconstruction may be a promising treatment for peri-acetabular malignant bone tumour; however, it is associated with a high complication rate. Therefore, prosthetic design and approach of prosthetic reconstruction after tumour resection warrant study. We retrospectively analyzed 11 patients with peri-acetabular malignant bone tumours treated by personalized 3D-printed hemipelvic prostheses after en bloc resection between 2015 and 2016. Pre-operative and post-operative pain at rest was assessed according to a 10-cm VAS score. The results of functional improvement were evaluated using the MSTS-93 score at the final follow-up. We also analyzed tumour recurrence, metastases, and complications associated with the reconstruction procedure. All patients were observed for six to 24 months with an average follow-up of 15.5 months. One patient had occasional pain of the involved hip at the final follow-up (VAS, pre vs. post 8 months: 3 vs. 2). The mean MSTS-93 score was 19.2 (range, 13-25). Hip dislocation was detected in two patients, while delayed wound healing occurred in one patient. One patient with mesenchymal chondrosarcoma had a left iliac bone metastasis. Local tumour recurrence was not observed. Reconstruction of bony defect after tumour resection using personalized 3D-printed hemipelvic prostheses can obtain acceptable functional results without severe complications. Based on previous reports and our results, we believe that reconstruction arthroplasty using 3D-printed hemipelvic prostheses will provide a promising alternative for those patients with peri-acetabular malignant bone tumours. Level IV, therapeutic study.

  5. Influence of Ophthalmic Solutions on Tear Components.

    Science.gov (United States)

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko

    2016-11-01

    Tear fluids are a mixture of secretions derived from lacrimal glands, accessory lacrimal glands, conjunctiva, and meibomian glands. Compositional changes to tears occur in the normal state and during ocular surface disease, such as dry eye conditions. We have investigated compositional changes to tears after topical application of ophthalmic solutions, with regard to tear-specific proteins (secretory immunoglobulin A, lactoferrin, lipocalin-1, and lysozyme) and ocular surface mucin in normal and dry eye conditions using high-performance liquid chromatography. After application of saline solution (0.9% sodium chloride) in normal subjects, transient but significant decreases in all tear components were observed. The recovery of protein concentrations took up to 30 minutes and lasted longer when the saline solution was applied more frequently. When applying ophthalmic solutions, a balance between washout and dilutional effects should be considered in addition to the therapeutic effect. Investigation of the effect of diquafosol solution (3%) in normal subjects revealed a significant increase in sialic acid concentration, a marker of ocular mucin, at 5 minutes after application, whereas a significant decrease was observed with saline. This result indicates the accelerated secretion of mucin from ocular tissues induced by diquafosol. A clinical study to determine the efficacy of diquafosol in patients with dry eye revealed improvements in tear breakup time, keratoconjunctival staining scores, and Schirmer test score, accompanied by an increase in sialic acid concentration in tears. Investigating normal and dry eye conditions through tear analysis may clarify the pathophysiology of dry eye conditions and support the efficacy of treatments.

  6. Efficacy of artificial tears for children xerophthalmia

    Directory of Open Access Journals (Sweden)

    Jie Yang

    2016-03-01

    Full Text Available AIM:To observe the efficacy and safety of artificial tears for children xerophthalmia.METHODS:Fifty-eight cases with 116 eyes were diagnosed as xerophthalmia by tear break-up time(BUT, Schirmer Ⅰ test(SⅠt, tear meniscus height, corneal staining, meibomian gland function test and were given artificial tears therapy for 1mo. Then the aforementioned tests were conducted again for statistical analysis.RESULTS:The mean BUT of all the children before treatments was 6.03±1.19s, SⅠt was 7.67±2.32mm/5min, tear meniscus height was 0.20±0.02mm, corneal staining was 1.02±0.13 scores and meibomian gland function was 2.45±0.86 scores. Sixty-two eyes in 31 cases were the lipid-deficient type, 40 eyes in 20 cases were aqueous-deficient type, and 14 eyes in 7 cases were other types. According to their types, corresponding artificial tears therapy was given. At 1mo after treatments, the clinical symptoms were improved significantly. BUT was 13.72±1.83s, SⅠt was 12.38±3.64mm/5min, tear meniscus height was 0.36±0.08mm, corneal fluorescein staining was 0.03±0.24 scores and meibomian gland function was 1.57±0.93 scores. Compared with those before treatments, the difference of each observed indicators was statistically significant(PCONCLUSION:Artificial tears treatment for children xerophthalmia is safe and effective.

  7. Long-Term MRI Findings in Operated Rotator Cuff Tear

    International Nuclear Information System (INIS)

    Kyroelae, K.; Niemitukia, L.; Jaroma, H.; Vaeaetaeinen, U.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings at long-term follow-up after rotator cuff (RC) tear using standard MRI sequences without fat saturation. Material and Methods: Twenty-eight patients aged 55.8±7.6 underwent MRI examination 4.6±2.1 years after surgery for RC tear. Standard sequences in oblique coronal, oblique sagittal, and axial planes were obtained. The RC, including re-tears and tendon degeneration, was independently evaluated by two observers. Thickness of the supraspinatus tendon and narrowing of the subacromial space were measured. The clinical outcome was evaluated with the Constant score and compared with the MRI findings. Results: The RC tear was traumatic in 18 (64%) patients and degenerative in 10 (36%). At follow-up, 11 (39%) had normal RC tendons with good clinical outcome. Four (14%) patients had painful tendinosis without RC tear. A full-thickness RC tear was found in 7 (25%) patients and a partial tear in 6 (21%). In one patient with a full-thickness tear, and in two with partial tear, tendinosis was found in another of the RC tendons. The subacromial space was narrowed in 13 (46%) of the patients. A narrowing of the subacromial space correlated with re-tear (P<0.05). Conclusions: The RC may be evaluated with standard MRI sequences without fat saturation at long-term follow-up. A normal appearance of the RC is correlated with good clinical outcome, while re-tear and tendinosis are associated with pain

  8. Epidemiology, natural history, and indications for treatment of rotator cuff tears.

    Science.gov (United States)

    Tashjian, Robert Z

    2012-10-01

    The etiology of rotator cuff disease is likely multifactorial, including age-related degeneration and microtrauma and macrotrauma. The incidence of rotator cuff tears increases with aging with more than half of individuals in their 80s having a rotator cuff tear. Smoking, hypercholesterolemia, and genetics have all been shown to influence the development of rotator cuff tearing. Substantial full-thickness rotator cuff tears, in general, progress and enlarge with time. Pain, or worsening pain, usually signals tear progression in both asymptomatic and symptomatic tears and should warrant further investigation if the tear is treated conservatively. Larger (>1-1.5 cm) symptomatic full-thickness cuff tears have a high rate of tear progression and, therefore, should be considered for earlier surgical repair in younger patients if the tear is reparable and there is limited muscle degeneration to avoid irreversible changes to the cuff, including tear enlargement and degenerative muscle changes. Smaller symptomatic full-thickness tears have been shown to have a slower rate of progression, similar to partial-thickness tears, and can be considered for initial nonoperative treatment due to the limited risk for rapid tear progression. In both small full-thickness tears and partial-thickness tears, increasing pain should alert physicians to obtain further imaging as it can signal tear progression. Natural history data, along with information on factors affecting healing after rotator cuff repair, can help guide surgeons in making appropriate decisions regarding the treatment of rotator cuff tears. The management of rotator cuff tears should be considered in the context of the risks and benefits of operative versus nonoperative treatment. Tear size and acuity, the presence of irreparable changes to the rotator cuff or glenohumeral joint, and patient age should all be considered in making this decision. Initial nonoperative care can be safely undertaken in older patients (>70

  9. A prospective evaluation of survivorship of asymptomatic degenerative rotator cuff tears.

    Science.gov (United States)

    Keener, Jay D; Galatz, Leesa M; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Stobbs-Cucchi, Georgia; Patton, Rebecca; Yamaguchi, Ken

    2015-01-21

    The purpose of this prospective study was to report the long-term risks of rotator cuff tear enlargement and symptom progression associated with degenerative asymptomatic tears. Subjects with an asymptomatic rotator cuff tear in one shoulder and pain due to rotator cuff disease in the contralateral shoulder enrolled as part of a prospective longitudinal study. Two hundred and twenty-four subjects (118 initial full-thickness tears, fifty-six initial partial-thickness tears, and fifty controls) were followed for a median of 5.1 years. Validated functional shoulder scores were calculated (visual analog pain scale, American Shoulder and Elbow Surgeons [ASES], and simple shoulder test [SST] scores). Subjects were followed annually with shoulder ultrasonography and clinical evaluations. Tear enlargement was seen in 49% of the shoulders, and the median time to enlargement was 2.8 years. The occurrence of tear-enlargement events was influenced by the severity of the final tear type, with enlargement of 61% of the full-thickness tears, 44% of the partial-thickness tears, and 14% of the controls (p tear enlargement. One hundred subjects (46%) developed new pain. The final tear type was associated with a greater risk of pain development, with the new pain developing in 28% of the controls, 46% of the shoulders with a partial-thickness tear, and 50% of those with a full-thickness tear (p tear enlargement was associated with the onset of new pain (p muscle were associated with tear enlargement, with supraspinatus muscle degeneration increasing in 4% of the shoulders with a stable tear compared with 30% of the shoulders with tear enlargement (p tear showed increased infraspinatus muscle degeneration compared with 28% of those in which the tear had enlarged (p = 0.07). This study demonstrates the progressive nature of degenerative rotator cuff disease. The risk of tear enlargement and progression of muscle degeneration is greater for shoulders with a full-thickness tear, and tear

  10. Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis.

    Science.gov (United States)

    Wang, Xuyi; Peng, Jianping; Li, De; Zhang, Linlin; Wang, Hui; Jiang, Leisheng; Chen, Xiaodong

    2016-10-04

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the "normal" range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the "normal" range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the "normal" range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological "normal" range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the "normal" range, within the "normal" range, and less than the lower limit of the "normal" range, respectively.

  11. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    2017-01-01

    in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT).PurposeTo test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed...... with single-energy CT (SECT) and DECT in cemented and cementless cups.Material and Methods: Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed.......Results: BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found...

  12. Kinetic theory of tearing instabilities

    International Nuclear Information System (INIS)

    Drake, J.F.; Lee, Y.C.

    1977-01-01

    The transition of the tearing instability from the collisional to the collisionless regime is investigated kinetically using a Fokker--Planck collision operator to represent electron-ion collisions. As a function of the collisionality of the plasma, the tearing instability falls into three regions, which are referred to as collisionless, semi-collisional, and collisional. The width Δ of the singular layer around kxB 0 =0 is limited by electron thermal motion along B 0 in the collisional and semi-collisional regimes and is typically smaller than rho/sub i/, the ion Larmor radius. Previously accepted theories, which are based on the assumption Δvery-much-greater-thanrho/sub i/, are found to be valid only in the collisional regime. The effects of density and temperature gradients on the instabilities are also studied. The tearing instability is only driven by the temperature gradient in the collisional and semi-collisional regimes. Numerical calculations indicate that the semi-collisional tearing instability is particularly relevant to present day high temperature tokamak discharges

  13. Posterior horn medial meniscal root tear: the prequel

    Energy Technology Data Exchange (ETDEWEB)

    Umans, H. [Albert Einstein College of Medicine, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, New York, NY (United States); Morrison, W. [Thomas Jefferson University Hospital, Philadelphia, PA (United States); DiFelice, G.S. [Hospital for Special Surgery, New York, NY (United States); Vaidya, N. [Crystal Run Healthcare, Middletown, NY (United States); Winalski, C.S. [Cleveland Clinic, Imaging Institute, Department of Biomedical Engineering, Lerner Research Institute, Cleveland, OH (United States)

    2014-06-15

    To determine whether subarticular marrow changes deep to the posterior horn medial meniscal root anchor might predict subsequent medial meniscal root tear. Fifteen patients with MR-diagnosed posterior horn medial meniscal root (PHMMR) tear and a knee MRI antecedent to the tear were identified at three imaging centers over a 7-year period. The pre- and post-tear MR images were evaluated for marrow signal changes deep to the root anchor, meniscal root signal intensity, medial compartment articular cartilage thinning, and meniscal body extrusion. Images of 29 age- and gender-matched individuals with two MRIs of the same knee were reviewed as a control group. MRI in 11 of 15 (73 %) cases with subsequent PHMMR tear demonstrated linear subcortical marrow edema deep to the meniscal root anchor on the antecedent MRI compared to only 1 of 29 (3 %) non-tear controls (p < 0.0001). The abnormal signal resolved on post-tear MRI in all but two patients. Cyst-like changes deep to the PHMMR were present on initial MRI in three of 15 (23 %) cases and three of 29 (10 %) controls, persisting in all but one case on follow-up imaging. The PHMMR was gray on the initial MRI in seven of 15 (47 %) of cases that developed tears compared to four of 29 (14 %) controls (p < 0.0001). There was medial meniscal extrusion (MME) prior to tear in two of 15 (13 %) patients and in ten of 15 (67 %) patients after PHMMR failure. In the control group, MME was present in one (3 %) and three (10 %) of 29 subjects on the initial and follow-up MRIs, respectively. Articular cartilage loss was noted in two of 15 (15 %) cases before tear and nine of 15 (69 %) on follow-up imaging, as compared to one (3 %) and four (14 %) of 29 subjects in the control group. Subcortical marrow edema deep to the PHMMR may result from abnormal stresses and thus be a harbinger of meniscal root failure. This hypothesis is supported by resolution of these marrow signal changes after root tear. Following tear, extrusion of the

  14. Human tears reveal insights into corneal neovascularization.

    Science.gov (United States)

    Zakaria, Nadia; Van Grasdorff, Sigi; Wouters, Kristien; Rozema, Jos; Koppen, Carina; Lion, Eva; Cools, Nathalie; Berneman, Zwi; Tassignon, Marie-José

    2012-01-01

    Corneal neovascularization results from the encroachment of blood vessels from the surrounding conjunctiva onto the normally avascular cornea. The aim of this study is to identify factors in human tears that are involved in development and/or maintenance of corneal neovascularization in humans. This could allow development of diagnostic tools for monitoring corneal neovascularization and combination monoclonal antibody therapies for its treatment. In an observational case-control study we enrolled a total of 12 patients with corneal neovascularization and 10 healthy volunteers. Basal tears along with reflex tears from the inferior fornix, superior fornix and using a corneal bath were collected along with blood serum samples. From all patients, ocular surface photographs were taken. Concentrations of the pro-angiogenic cytokines interleukin (IL)-6, IL-8, Vascular Endothelial Growth Factor (VEGF), Monocyte Chemoattractant Protein 1 (MCP-1) and Fas Ligand (FasL) were determined in blood and tear samples using a flow cytometric multiplex assay. Our results show that the concentration of pro-angiogenic cytokines in human tears are significantly higher compared to their concentrations in serum, with highest levels found in basal tears. Interestingly, we could detect a significantly higher concentration of IL- 6, IL-8 and VEGF in localized corneal tears of patients with neovascularized corneas when compared to the control group. This is the first study of its kind demonstrating a significant difference of defined factors in tears from patients with neovascularized corneas as compared to healthy controls. These results provide the basis for future research using animal models to further substantiate the role of these cytokines in the establishment and maintenance of corneal neovascularization.

  15. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  16. Migration measurement of acetabular components in cementless total hip arthroplasty; Messung der Pfannenwanderung bei zementfreien Hueftimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, A.; Karbowski, A.; Schwitalle, M.; Vogel, J.; Boden, F.; Seeleitner, C. [Mainz Univ. (Germany). Orthopaedische Klinik und Poliklinik; Schunk, K. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Mayrhofer, P. [Innsbruck Univ. (Austria). Inst. fuer Mathematik und Geometrie

    1998-08-01

    Migration measurements of acetabular components using a special computer aided method (EBRA = abbrevation for the German term ``Ein-Bild-Roentgenanalyse``) were performed to evaluate early results of the implants and predict aseptic loosening. Methods: Standard ap-radiographs of the pelvis were marked, specific points were digitised. Simulating the spatial situation the programme computes lengitudinal and vertical migration of the cup. 74 acetabular components in 71 patients could be studied by migration measurements. Results: 14 patients showed migration of more than 1 mm, which is the confidence limit of this method. Each of these patients showed diverse reasons for the migration, i.e. osteoporosis of the acetabular bone stock or problems concerning the surgical technique which means malposition of the cup or insufficient reaming of the bone. There were some patients with severe congenital dysplasia of the hip and in some cases the inclination angle of the cup was too great. Conclusion: The technique applied for measuring migration of acetabular components can be useful for evaluating early instability of the implant and can be helpful in detecting problems concerning the surgical technique. (orig.) [Deutsch] Mittels der Ein-Bild-Roentgenanalyse wurden Pfannenwanderungen nach Implantation von zementfreien, sphaerischen Hueftgelenkspfannen erfasst, um Praediktoren fuer die langfristige Prognose der Implantate zu evaluieren. Methoden: Nach Markierung von Referenzpunkten in den Beckenuebersichtsaufnahmen wurden diese digitalisiert, vom Programm verrechnet und die Wanderung des Implantats im Verlauf angegeben. Bei 71 Patienten wurden von 74 Pfannen ueber einen Mindestnachuntersuchungszeitraum von 12 Monaten Migrationsmessungen durchgefuehrt. Das Konfidenzintervall der Methode liegt bei <1 mm. Bei jedem dieser Patienten fanden sich Hinweise entweder auf ein schlechtes Knochenlager, auf operationsbedingte Probleme, wenn keine ausreichende Primaerstabilitaet der Pfanne

  17. The natural course of nonoperatively treated rotator cuff tears: an 8.8-year follow-up of tear anatomy and clinical outcome in 49 patients.

    Science.gov (United States)

    Moosmayer, Stefan; Gärtner, Anne V; Tariq, Rana

    2017-04-01

    The natural course of nonoperatively treated rotator cuff tears is not fully understood. We explored the long-term development of tear anatomy and assessed functional outcomes. Eighty-nine small to medium-sized full-thickness tears of the rotator cuff, all primarily treated by physiotherapy, were identified retrospectively. Twenty-three tears needed surgical treatment later on, and 17 patients were unable to meet for follow-up. The remaining 49 still unrepaired tears were re-examined after 8.8 (8.2-11.0) years with sonography. Re-examination by magnetic resonance imaging was possible for 37 patients. Shoulder function was assessed with shoulder scores. Primary outcome measures were progression of tear size, muscle atrophy, and fatty degeneration and the Constant score (CS). Mean tear size increased by 8.3 mm in the anterior-posterior plane (P = .001) and by 4.5 mm in the medial-lateral plane (P = .001). Increase of tear size was -5 to +9.9 mm in 33 patients, 10 to 19.9 mm in 8 patients, and ≥20 mm in 8 patients. The CS was 81 points for tear increases Muscle atrophy and fatty degeneration progressed in 18 and 15 of the 37 patients, respectively. In tears with no progression of atrophy, the CS was 82 points compared with 75.5 points in tears with progression (P = .04). Anatomic tear deterioration was found in the majority of patients, but it was often moderate. Large tear size increases and progression of muscle atrophy were correlated to a poorer functional outcome. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

    Directory of Open Access Journals (Sweden)

    Reza Firoozabadi

    2015-09-01

    Full Text Available Purpose: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnormalities to aid surgeons in detecting these abnormalities preoperatively and coordinating a surgical plan with a general surgeon.Methods: Clinical study- Retrospective review of treated acetabular fractures through an ilioinguinal approach. Incidence of inguinal canal and spermatic cord abnormalities requiring general surgery consultation were identified. Corresponding CT scans were reviewed and radiographic characteristics of the spermatic cord abnormalities and/or hernias were noted.Cadaveric study- 18 male cadavers dissected bilaterally using an ilioinguinal exposure. The inguinal canal and the contents of the spermatic cord were identified and characterized.Results: Clinical Study- 5.7% (5/87 of patients had spermatic cord lesion and/or inguinal hernia requiring general surgical intervention. Preoperative pelvic CT scan review identified abnormalities noted intraoperatively in four of the five patients. Cord lipomas visualized as enlargements of the spermatic cord with homogeneous density. Hernias visualized as enlarged spermatic cords with heterogeneous density. Cadaver Study- 31% (11/36 of cadavers studied had spermatic cord and/or inguinal canal abnormalities. Average cord diameter in those with abnormalities was 24.9 mm (15-28 compared to 16 mm (11-22 in normal cords, which was statistically significant.Conclusion: The clinical and cadaveric findings emphasize the importance of understanding inguinal abnormalities and the value of detecting them preoperatively. The preoperative pelvic CT scans were highly sensitive in detecting inguinal abnormalities.

  19. [Stress analysis on the acetabular side of bipolar hemiarthroplasty by the two-dimensional finite element method incorporating the boundary friction layer].

    Science.gov (United States)

    Ichihashi, K; Imura, S; Oomori, H; Gesso, H

    1994-11-01

    We compared the biomechanical characteristics of bipolar and unipolar hemiarthroplasty on the proximal migration of the outer head by determining the von Mises stress distribution and acetabular (outer head) displacement with clinical assessment of hemiarthroplasty in 75 patients. This analysis used the two-dimensional finite element method, which incorporated boundary friction layers on both the inner and outer bearings of the prosthesis. Acetabular reaming increased stress within the pelvic bone and migration of the outer head. A combination of the acetabular reaming and bone transplantation increased the stress within the pelvic bone and grafted bone, and caused outer head migration. These findings were supported by clinical results. Although the bipolar endoprosthesis was biomechanically superior to the unipolar endoprosthesis, migration of the outer head still occurred. The bipolar endoprosthesis appeared to be indicated in cases of a femoral neck fracture or of avascular necrosis in the femoral head, but its use in cases of osteoarthritis in the hip required caution.

  20. Age-related changes in the signal value of tears.

    Science.gov (United States)

    Zeifman, Debra M; Brown, Sarah A

    2011-08-12

    Emotional tears may be uniquely human and are an effective signal of distress in adults. The present study explored whether tears signal distress in younger criers and whether the effect of tears on observers is similar in magnitude across the life span. Participants rated photographs of crying infants, young children, and adults, with tears digitally removed or added. The effectiveness of tears in conveying sadness and eliciting sympathy was greatest for images of adults, intermediate for images of children, and least potent for images of infants. These findings suggest that the signal value of tears varies with the age of the crier. The results may shed light on the functional significance of crying at different stages of human development.

  1. Time course of changes in tear meniscus radius and blink rate after instillation of artificial tears.

    Science.gov (United States)

    Bandlitz, Stefan; Purslow, Christine; Murphy, Paul J; Pult, Heiko

    2014-08-26

    Using a novel digital meniscometer (PDM), alterations in tear meniscus radius (TMR) were measured simultaneously with blink rate (BR) following the instillation of artificial tears. Central TMR and BR of 22 subjects (11 male and 11 female; mean age, 24.3 ± 2.6 SD years) were measured at baseline, and 0, 1, 5, 10, and 30 minutes after instillation of an artificial tear containing hydroxypropyl-guar and glycol (SYS) or saline (SAL). A dose of 35 μL was applied in one eye in a randomized order with a washout period between each drop. For SAL, compared to baseline TMR (0.33 ± 0.08 mm), TMR significantly increased with drop instillation (1.55 ± 0.69 mm) and at 1 minute (0.66 ± 0.36 mm; P tears. Difference in residence time reflects the different viscosity of each drop. An overload with a large drop may result in an initially increased BR. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  2. MR Imaging of Rotator Cuff Tears: Correlation with Arthroscopy

    Science.gov (United States)

    Bhandary, Sudarshan; Khandige, Ganesh; Kabra, Utkarsh

    2017-01-01

    Introduction Rotator cuff tears are quite common and can cause significant disability. Magnetic Resonance Imaging (MRI) has now emerged as the modality of choice in the preoperative evaluation of patients with rotator cuff injuries, in view of its improved inherent soft tissue contrast and resolution. Aim To evaluate the diagnostic accuracy of routine MRI in the detection and characterisation of rotator cuff tears, by correlating the findings with arthroscopy. Materials and Methods This prospective study was carried out between July 2014 and August 2016 at the AJ Institute of Medical Sciences, Mangalore, Karnataka, India. A total of 82 patients were diagnosed with rotator cuff injury on MRI during this period, out of which 45 patients who underwent further evaluation with arthroscopy were included in this study. The data collected was analysed for significant correlation between MRI diagnosis and arthroscopic findings using kappa statistics. The sensitivity, specificity, predictive value and accuracy of MRI for the diagnosis of full and partial thickness tears were calculated using arthroscopic findings as the reference standard. Results There were 27 males and 18 females in this study. The youngest patient was 22 years and the oldest was 74 years. Majority of rotator cuff tears (78%) were seen in patients above the age of 40 years. MRI showed a sensitivity of 89.6%, specificity of 100%, positive predictive value of 100% and negative predictive value of 83.3% for the diagnosis of full thickness rotator cuff tears. For partial thickness tears, MRI showed a sensitivity of 100%, specificity of 86.6%, positive predictive value of 78.9% and negative predictive value of 100%. The accuracy was 93.1% for full thickness tears and 91.1% for partial thickness tears. The p-value was less than 0.01 for both full and partial thickness tears. There was good agreement between the MRI and arthroscopic findings, with kappa value of 0.85 for full thickness tears and 0.81 for partial

  3. Meniscotibial (coronary) ligament tears

    International Nuclear Information System (INIS)

    El-Khoury, G.Y.; Usta, H.Y.; Berger, R.A.

    1984-01-01

    Preservation of the meniscus whenever possible is essential in maintaining knee stability and preventing premature osteoarthritis. Peripheral meniscal tears are the most amenable to surgical repair. This study evaluates the peripheral attachments of the medial meniscus and focuses on a specific tear limited to the meniscotibial ligament (coronary ligament). The diagnosis is made arthrographically when the medial meniscus floats above the tibial plateau without separating completely from the capsule. The lateral meniscus is rarely involved in this type of injury. (orig.)

  4. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study

    DEFF Research Database (Denmark)

    Baad-Hansen, Thomas; Kold, Søren; Kaptein, Bart L

    2007-01-01

    BACKGROUND: In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years...

  5. Arthroscopic rotator cuff repair in elite rugby players.

    Science.gov (United States)

    Tambe, Amol; Badge, Ravi; Funk, Lennard

    2009-01-01

    Rugby is an increasingly popular collision sport. A wide spectrum of injuries can be sustained during training and match play. Rotator cuff injury is uncommon in contact sports and there is little published literature on the treatment of rotator cuff tears in rugby players. We therefore reviewed the results and functional outcomes of arthroscopic rotator cuff repair in elite rugby players. Eleven professional rugby players underwent arthroscopic rotator cuff repair at our hospital over a 2-year period. We collected data on these patients from the operative records. The patients were recalled for outcome scoring and ultrasound scans. There were seven rugby league players and four rugby union players, including six internationals. Their mean age was 25.7 years. All had had a traumatic episode during match play and could not return to the game after the injury. The mean time to surgery was 5 weeks. The mean width of the cuff tear was 1.8 cm. All were full- thickness cuff tears. Associated injuries included two Bankart lesions, one bony Bankart lesion, one posterior labral tear, and two 360 degrees labral tears. The biceps was involved in three cases. Two were debrided and a tenodesis was performed in one. Repair was with suture anchors. Following surgery, all patients underwent a supervised accelerated rehabilitation programme. The final follow-up was at 18 months (range: 6-31 months) post surgery. The Constant scores improved from 44 preoperatively to 99 at the last follow-up. The mean score at 3 months was 95. The Oxford shoulder score improved from 34 to 12, with the mean third month score being 18. The mean time taken to return to full match play at the preinjury level was 4.8 months. There were no complications in any of the patients and postoperative scans in nine patients confirmed that the repairs had healed. We conclude that full-thickness rotator cuff tears in the contact athlete can be addressed successfully by arthroscopic repair, with a rapid return to

  6. Advanced Rotator Cuff Tear Score (ARoCuS): a multi-scaled tool for the classification and description of rotator cuff tears.

    Science.gov (United States)

    Walter, S G; Stadler, T; Thomas, T S; Thomas, W

    2018-03-02

    To introduce a (semi-)quantitative surgical score for the classification of rotator cuff tears. A total of 146 consecutive patients underwent rotator cuff repair and were assessed using the previously defined Advanced Rotator Cuff Tear Score (ARoCuS) criteria: muscle tendon, size, tissue quality, pattern as well as mobilization of the tear. The data set was split into a training (125 patients) and a testing set (21 patients). The training data set fitted a nonlinear predictive model of the tear score based on the ARoCuS criteria, while the testing data served as control. Based on the scoring results, rotator cuff tears were assigned to one of four categories (ΔV I-IV) and received a stage-adapted treatment. For statistical analysis, mean values ± standard deviation, interclass correlation coefficients (ICC) and kappa values were calculated. Overall, 32 patients were classified as ΔV I, 68 as ΔV II and 37 as ΔV III. Nine patients showed ΔV IV tears. Patients of all ΔV groups improved significantly their Constant scores (p tears in a standardized and reproducible manner.

  7. Surgical treatment of acetabular fractures: clinical and radiological results and its complications

    International Nuclear Information System (INIS)

    Martinez, C; Rey, R.

    2011-01-01

    The objective of this work is to analyse a serie of consecutive cases of surigically treated acetabular fractures, evaluating middle-term clinical and radiological results. A retrospective analysis of clinical histories, surgical forms and X-rays was performed for 42 patients who underwent surgery in two centers (Instituto Nacional de Ortopedia y Traumatologia [INOT] and Banco de Protesis), from July 2001 through August 2007

  8. Detecting meniscal tears in primary care

    NARCIS (Netherlands)

    Snoeker, B.A.M.

    2017-01-01

    Although meniscal tears are a very common phenomenon uncertainty exists about the diagnosis and treatment of meniscal tears in primary care. This thesis aims to provide evidence for general practitioners and physical therapists regarding the diagnosis and management of patients with a suspected

  9. Is radiation superior to indomethacin to prevent heterotopic ossification in acetabular fractures?: a systematic review.

    NARCIS (Netherlands)

    Blokhuis, T.J.; Frolke, J.P.M.

    2009-01-01

    Heterotopic ossification is a well-known complication after fixation of an acetabular fracture. Indomethacin and radiation therapy are used as prophylaxis to prevent heterotopic ossification. It is unclear, however, whether either is superior, although this may relate to lack of power in individual

  10. Duplex Tear Film Evaporation Analysis.

    Science.gov (United States)

    Stapf, M R; Braun, R J; King-Smith, P E

    2017-12-01

    Tear film thinning, hyperosmolarity, and breakup can cause irritation and damage to the human eye, and these form an area of active investigation for dry eye syndrome research. Recent research demonstrates that deficiencies in the lipid layer may cause locally increased evaporation, inducing conditions for breakup. In this paper, we explore the conditions for tear film breakup by considering a model for tear film dynamics with two mobile fluid layers, the aqueous and lipid layers. In addition, we include the effects of osmosis, evaporation as modified by the lipid, and the polar portion of the lipid layer. We solve the system numerically for reasonable parameter values and initial conditions and analyze how shifts in these cause changes to the system's dynamics.

  11. Magnetic Resonance Imaging Currently Fails to Fully Evaluate the Biceps-Labrum Complex and Bicipital Tunnel.

    Science.gov (United States)

    Taylor, Samuel A; Newman, Ashley M; Nguyen, Joseph; Fabricant, Peter D; Baret, Nikolas J; Shorey, Mary; Ramkumar, Prem; O'Brien, Stephen J

    2016-02-01

    To determine the diagnostic accuracy of magnetic resonance imaging (MRI) for biceps-labrum complex (BLC) lesions, including the extra-articular bicipital tunnel. A retrospective review of 277 shoulders with chronic refractory BLC symptoms that underwent arthroscopic subdeltoid transfer of the long head of the biceps tendon (LHBT) to the conjoint tendon was conducted. Intraoperative lesions were categorized as "inside" (labral tears and dynamic LHBT incarceration), "junctional" (LHBT partial tears, LHBT subluxation, and biceps chondromalacia), or "bicipital tunnel" (extra-articular bicipital tunnel scar/stenosis, loose bodies, LHBT instability, and LHBT partial tears) based on anatomic location. Attending radiologist-generated MRI reports were graded dichotomously as positive or negative for biceps and labral damage and then compared with intraoperative findings. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for MRI with respect to intraoperative findings. With regard to inside lesions, MRI had an overall sensitivity, specificity, PPV, and NPV for labrum lesions of 77.3%, 68.2%, 57.3%, and 84.5% respectively. The sensitivity, specificity, PPV, and NPV of MRI for junctional lesions were 43.3%, 55.6%, 73.1%, and 26.0%, respectively. For the bicipital tunnel, MRI had a sensitivity, specificity, PPV, and NPV of 50.4%, 61.4%, 48.7%, and 63.0%, respectively. MRI was unreliable for ruling out BLC lesions among chronically symptomatic patients, including when the bicipital tunnel was affected. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Diet, nutraceuticals and the tear film.

    Science.gov (United States)

    Jalbert, Isabelle

    2013-12-01

    Nutrition disorders and their correlates such as obesity are increasingly prevalent worldwide. A number of studies to date have suggested numerous potential associations between diet and tear film health; this paper will provide a summary of the available literature. The tear film is characterized through its protein and lipid content and through clinical measurements of characteristics such as osmolarity, volume and stability. Malnutrition, protein and vitamin-A deficiencies are extremely deleterious to tear film health and supplementation with oral vitamin A in this setting is of clear benefit. The relative impact of diet on tear film within what would be considered normal ranges of consumption is less clear. A number of population studies have suggested that hyperlipidemia and a diet low in omega-3 fatty acids are risks factor for dry eye disease. Numerous studies have investigated the effectiveness of oral supplementation with antioxidants, omega-3 (e.g. fish oil and linseed oil) and omega-6 (e.g. evening primrose oil) fatty acids in the last 10 years. Taken together, these suggest a small benefit of oral supplementation on tear film volume, stability and decreased ocular symptoms in patients previously diagnosed with diseases involving the ocular surface (e.g. Sjögren's syndrome, meibomian gland dysfunction, dry eye disease) and contact lens wearers suffering from dry eye. More research is required to determine the exact composition, dosage and indications for their use and to fully characterize how these nutraceuticals modulate the tear film. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. MRI evaluation of the posterior meniscus root tear

    International Nuclear Information System (INIS)

    Zhang Jianjun; Zheng Zhuozhao; Li Xuan

    2010-01-01

    Objective: To determine the value of MRI for diagnosing the posterior meniscus root tear. Methods: MR examinations of 30 patients with tear of the posterior meniscus root confirmed by knee arthroscopies were retrospectively reviewed. Of the 30 patients, 17 with posterior medial meniscus root tear (MMRT) and 13 with posterior lateral meniscus root tear (LMRT). The diagnostic sensitivity of' MRI for the posterior meniscus root tear was analyzed. Fisher's exact test was used to compare the detection rate of MRI for MMRT with that for LMRT. Results: All 17 cases with MMRT and 9 cases out of 13 with LMRT were correctly diagnosed by MRI and the diagnostic sensitivity of MRI for the posterior meniscus root tear was 86.7% (26/30). The main MR appearance of the posterior meniscus root tear was distortion of the meniscal root, with its low signal replaced by abnormal high signal. The detection rate of MRI for MMRT (17/17) was significantly greater than that for LMRT (9/13) (P=0.026). The prevalence of MMRT associated with meniscus extrusion (15/17) was significantly greater than that of LMRT (6/13) (P=0.020), but the prevalence of MMRT associated with anterior cruciate ligament (ACL) injury (5/17) was significantly lower than that of LMRT (11/13) (P=0.004). Conclusion: MRI is a relatively good method for detection of posterior meniscus root tears and associated injuries. (authors)

  14. Comparison of Medial and Lateral Meniscus Root Tears.

    Directory of Open Access Journals (Sweden)

    Ji Hyun Koo

    Full Text Available The meniscus root plays an essential role in maintaining the circumferential hoop tension and preventing meniscal displacement. Studies on meniscus root tears have investigated the relationship of osteoarthritis and an anterior cruciate ligament tear. However, few studies have directly compared the medial and lateral root tears. To assess the prevalence of meniscal extrusion and its relationship with clinical features in medial and lateral meniscus root tears, we performed a retrospective review of the magnetic resonance imaging (MRI results of 42 knee patients who had meniscus posterior horn root tears and who had undergone arthroscopic operations. The presence of meniscal extrusion was evaluated and the exact extent was measured from the tibial margin. The results were correlated with arthroscopic findings. Clinical features including patients' ages, joint abnormalities, and previous trauma histories were evaluated. Twenty-two patients had medial meniscus root tears (MMRTs and twenty patients had lateral meniscus root tears (LMRTs. Meniscal extrusion was present in 18 MMRT patients and one LMRT patient. The mean extent of extrusion was 4.2mm (range, 0.6 to 7.8 in the MMRT group and 0.9mm (range, -1.9 to 3.4 in the LMRT group. Five patients with MMRT had a history of trauma, while 19 patients with LMRT had a history of trauma. Three patients with MMRT had anterior cruciate ligament (ACL tears, while 19 patients with LMRT had ACL tears. The mean age of the patients was 52 years (range: 29-71 years and 30 years (range: 14-62 years in the MMRT and LMRT group, respectively. There was a significant correlation between a MMRT and meniscal extrusion (p<0.0001, and between an ACL tear and LMRT (p<0.0001. A history of trauma was significantly common in LMRT (p<0.0001. LMRT patients were significantly younger than MMRT patients (p<0.0001. Kellgren-Lawrence (K-L grade differed significantly between MMRT and LMRT group (p<0.0001. Meniscal extrusion is

  15. Lipid peroxidation is increased in tears from the elderly.

    Science.gov (United States)

    Benlloch-Navarro, Soledad; Franco, Ilenia; Sánchez-Vallejo, Violeta; Silvestre, Dolores; Romero, Francisco Javier; Miranda, María

    2013-10-01

    We describe a procedure in which tears, obtained from Schirmer strips, are used to measure a marker of lipid peroxidation, malondialdehyde (MDA). We also compared the levels of proteins and MDA in tears from two groups of people: young adults (18-30 years old) and elderly adults (65-85 years old), because the data related to total protein concentration of human tears vary widely and because the majority of people over the age of 65 experience some symptoms of dry eyes and this condition has been recognized as an oxidative stress-induced disease. Our results show a significant difference in the protein concentration of the tears taken from the two age categories, younger adults (18-30 years old) and older adults (65-85 years old). Herein, we report for the first time an increase in MDA concentrations determined by HPLC in human tears based on age. It is possible that alterations in the tear lipid layer may lead to an increase in lipid peroxidation. Further studies are needed to understand the nature and function of tear film and stability in order to obtain new methods to analyze tears in patients with different diseases. In this sense, it would be interesting to compare MDA concentration in tears from control subjects and from people with meibomian gland dysfunction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Effects of tear film dynamics on quality of vision.

    Science.gov (United States)

    Koh, Shizuka; Tung, Cynthia I; Inoue, Yasushi; Jhanji, Vishal

    2018-06-15

    The precorneal tear film is maintained by blinking and exhibits different phases in the tear cycle. The tear film serves as the most anterior surface of the eye and plays an important role as a first refractive component of the eye. Alterations in tear film dynamics may cause both vision-related and ocular surface-related symptoms. Although the optical quality associated with the tear film dynamics previously received little attention, objective measurements of optical quality using wavefront sensors have enabled us to quantify optical aberrations induced by the tear film. This has provided an objective method for assessing reduced optical quality in dry eye; thus, visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. In addition, sequential measurements of wavefront aberrations have provided us with valuable insights into the dynamic optical changes associated with tear film dynamics. This review will focus on the current knowledge of the mechanisms of wavefront variations that are caused by different aspects of tear film dynamics: specifically, quality, quantity and properties of the tear film, demonstrating the respective effects of dry eye, epiphora and instillation of eye drops on the quality of vision. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. The social impact of emotional tears

    NARCIS (Netherlands)

    Vingerhoets, A.J.J.M.; van de Ven, N.; van der Velden, Y.

    2016-01-01

    The question what specific functions the production of emotional tears fulfills has received only limited attention of behavioral scientists. We report the results of two studies on the social impact of emotional tears. In Study 1 (96 Dutch females), perceived helplessness and felt connectedness

  18. [Acetabular anteversion angle of the hip in the Mexican adult population measured with computed tomography].

    Science.gov (United States)

    Rubalcava, J; Gómez-García, F; Ríos-Reina, J L

    2012-01-01

    Knowledge of the radiogrametric characteristics of a specific skeletal segment in a healthy population is of the utmost clinical importance. The main justification for this study is that there is no published description of the radiogrametric parameter of acetabular anteversion in a healthy Mexican adult population. A prospective, descriptive and cross-sectional study was conducted. Individuals of both genders older than 18 years and orthopedically healthy were included. They underwent a two-dimensional axial tomographic study of both hips to measure the acetabular anteversion angles. The statistical analysis consisted of obtaining central trend and scatter measurements. A multivariate analysis of variance (ANOVA) and statistical significance were performed. 118 individuals were studied, 60 males and 58 females, with a mean age of 47.7 +/- 16.7, and a range of 18-85 years. The anteversion of the entire group was 18.6 degrees + 4.1 degrees. Anteversion in males was 17.3 degrees +/- 3.5 degrees (10 degrees - 25 degrees) and in females 19.8 degrees +/- 4.7 degrees (10 degrees - 31 degrees). There were no statistically significant differences (p right and left anteversion in the entire group. However, there were statistically significant differences (p > or = 0.005) both in the right and left sides when males and females were compared. Our study showed that there are great variations in the anteversion ranges of a healthy population. When our results are compared with those published by other authors the mean of most measurements exceeds 15 degrees. This should be useful to make therapeutic decisions that involve acetabular anteversion.

  19. US detection of rotator cuff tear

    International Nuclear Information System (INIS)

    Soble, M.G.; Guay, R.C.; Kaye, A.D.

    1988-01-01

    Between June 1986 and April 1988, 75 patients suspected of having a tear of the rotator cuff underwent shoulder sonography and arthrography. Compared with anthrography, US demonstrated 92% of rotor cuff tears, with a specificity of 84% and a negative predictive value of 95%. In 30 patients who underwent surgery for a rotator cuff tear or other soft-tissue abnormality, sonography demonstrated a sensitivity of 93% and specificity of 73%, while arthrography demonstrated a sensitivity of 87% and specificity of 100%. The above data indicate that US is a useful, noninvasive screening procedure for patients suspected of having rotator cuff injury

  20. Proximal focal femoral deficiency: evaluation by MR imaging

    International Nuclear Information System (INIS)

    Biko, David M.; Davidson, Richard; Pena, Andres; Jaramillo, Diego

    2012-01-01

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  1. Proximal focal femoral deficiency: evaluation by MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [National Naval Medical Center, Department of Radiology, Bethesda, MD (United States); Uniformed Services University of Health Sciences, Department of Radiology and Radiological Sciences, Bethesda, MD (United States); Davidson, Richard [The Children' s Hospital of Philadelphia, Department of Orthopedic Surgery, Philadelphia, PA (United States); Pena, Andres; Jaramillo, Diego [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States)

    2012-01-15

    Proximal focal femoral deficiency (PFFD) is a rare congenital anomaly characterized by abnormal development of the proximal femur. The most common radiographic classification (Aitken) does not evaluate the cartilaginous and soft-tissue abnormalities. To demonstrate MR findings of PFFD focusing on features not seen with radiographs. Nine MR examinations of the hip and femurs of seven children with PFFD were retrospectively reviewed. Imaging was quantitatively and qualitatively assessed comparing the affected limb to the contralateral limb and age-matched controls. The children were classified via the Aitken classification. All children had at least mild acetabular dysplasia, and one type D patient had no acetabulum. MR demonstrated that 4/6 children had labral hypertrophy with a decreased distance from the greater trochanter to the acetabular rim, suggesting impingement (P < 0.05). The proximal femoral physis was abnormal in all cases. The connection between the femoral head and shaft if present was fibrous or fibrocartilaginous. MRI can help in evaluation of PFFD by defining the anatomy. MR demonstrates features of the acetabulum and cartilaginous femoral epiphysis and depicts ligamentous abnormalities of the knee. (orig.)

  2. Allergy and allergic mediators in tears.

    Science.gov (United States)

    Leonardi, Andrea

    2013-12-01

    The identification of inflammatory mediators in the tear fluid have been extensively used in ocular allergy to find either a 'disease marker', to better understand the immune mechanisms involved in the ocular surface inflammation, or to identify potential targets for therapeutic interventions. While the clinical characteristics allow a relatively convincing diagnosis of ocular allergic diseases, in the initial, non active phases, or in the chronic stages, the diagnosis may not be clear. Although not highly specific, total tear IgE can be measured with local tests by inserting a paper strip in the lower meniscus. The measurement of tear specific inflammatory markers, such as histamine, tryptase, ECP, IL-4, IL-5 and eotaxin, may be useful for the diagnosis or monitoring ocular allergy. New technologies such as multiplex bead assays, membrane-bound antibody array and proteomic techniques can characterize the distribution of a wide range of bioactive trace proteins in tears. Dozens of mediators, cytokines, chemokines, growth factors, angiogenic modulators, enzymes and inhibitors were thus identified in small tear samples using these techniques, providing the possible identification of specific biomarker for either specific disease or disease activity. However, to date, there is no a single specific laboratory test suitable for the diagnosis and monitoring of allergic conjunctivitis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. MR imaging of meniscal tears: correlation with history of trauma

    International Nuclear Information System (INIS)

    Choi, Jong Cheul; Yang, Seoung Oh; Choi, Sun Seob; Son, Seok Hyun; Lee, Yung Il; Chung, Duck Hwan; Kim, Kyung Taek; Sohn, Sung Keun; Lee, Jung Yoon

    1994-01-01

    The medial meniscus is injured much more than the lateral meniscus. Because the medial meniscus is much larger in diameter, is thinner in its periphery and narrower in body than the lateral meniscus, and dose not attach to either cruciate ligament. We evaluated correlations with sites of tear and history of trauma. We reviewed retrospectively in 43 patients with meniscal tears on MR(51 cases) and correlated them with history of trauma. The most common site of injury was the posterior horn of the medial meniscuc(32/51), but high incidence of lateral meniscal tear compared with previous reports was seen. In the cases which had history of trauma, the posterior horn of medial meniscus was most commonly injured(26/34) and 5 meniscal tears were combined with meniscal tear in the other site. The tear in the anterior horn of the medial meniscus was seen only in a patient which had history of trauma and combined with meniscal tear in the other site. But in the meniscal tears without definite history of trauma, the incidence of meniscal tear was different from the meniscal tear with history of trauma. The incidence of lateral meniscal tear(11/17) was higher than medial meniscal tear and the posterior horn of lateral meniscus was commonly injured. We concluded that the medial meniscus was commonly injured, especially posterior horn, but in the cases which had no definite history of trauma, the lateral meniscus was commonly injured. An awareness of prevalent site of meniscal injuries may be helpful in the diagnostic interpretation of MR imaging of knee

  4. Tearing modes with pressure gradient effect in pair plasmas

    International Nuclear Information System (INIS)

    Cai Huishan; Li Ding; Zheng Jian

    2009-01-01

    The general dispersion relation of tearing mode with pressure gradient effect in pair plasmas is derived analytically. If the pressure gradients of positron and electron are not identical in pair plasmas, the pressure gradient has significant influence at tearing mode in both collisionless and collisional regimes. In collisionless regime, the effects of pressure gradient depend on its magnitude. For small pressure gradient, the growth rate of tearing mode is enhanced by pressure gradient. For large pressure gradient, the growth rate is reduced by pressure gradient. The tearing mode can even be stabilized if pressure gradient is large enough. In collisional regime, the growth rate of tearing mode is reduced by the pressure gradient. While the positron and electron have equal pressure gradient, tearing mode is not affected by pressure gradient in pair plasmas.

  5. Tear dysfunction and the cornea: LXVIII Edward Jackson Memorial Lecture.

    Science.gov (United States)

    Pflugfelder, Stephen C

    2011-12-01

    To describe the cause and consequence of tear dysfunction-related corneal disease. Perspective on effects of tear dysfunction on the cornea. Evidence is presented on the effects of tear dysfunction on corneal morphology, function, and health, as well as efficacy of therapies for tear dysfunction-related corneal disease. Tear dysfunction is a prevalent eye disease and the most frequent cause for superficial corneal epithelial disease that results in corneal barrier disruption, an irregular optical surface, light scattering, optical aberrations, and exposure and sensitization of pain-sensing nerve endings (nociceptors). Tear dysfunction-related corneal disease causes irritation and visual symptoms such as photophobia and blurred and fluctuating vision that may decrease quality of life. Dysfunction of 1 or more components of the lacrimal functional unit results in changes in tear composition, including elevated osmolarity and increased concentrations of matrix metalloproteinases, inflammatory cytokines, and chemokines. These tear compositional changes promote disruption of tight junctions, alter differentiation, and accelerate death of corneal epithelial cells. Corneal epithelial disease resulting from tear dysfunction causes eye irritation and decreases visual function. Clinical and basic research has improved understanding of the pathogenesis of tear dysfunction-related corneal epithelial disease, as well as treatment outcomes. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2014-01-01

    Full Text Available Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC. Twenty-nine patients (32 implants died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years. There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years, with Paprosky IIIA (27 cases and IIIB (38 cases acetabular bone defects. Nine cages required rerevision because of infection (3, aseptic loosening (5, and flange breakage (1. The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P<0.001. Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival.

  7. Immunoglobulin Concentration in Tears of Contact Lens Wearers

    Science.gov (United States)

    Maurya, Rajendra P.; Bhushan, Prashant; Singh, Virendra P.; Singh, Mahendra K.; Kumar, Prakash; Bhatia, Ravindra P.S.; Singh, Usha

    2014-01-01

    Purpose: To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. Methods: A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. Results: Most of the cases used soft (56.6%) and semi-soft gas permeable (30.4%) contact lenses. Tear IgM was detected in only 17.4% and tear IgG in 43.6% of contact lens wearers, while in controls IgG was detected in 9.1% but none of the controls had IgM. There was a significant rise in total tear IgA (13.17 ± 4.44 mg/dl) in contact lens wearer as compared to controls (8.93 ± 3.79 mg/dl). Rise of tear IgA was more in symptomatic patients (15.38 ± 5.28 mg/dl) and in those wearing hard (19.73 ± 5.43 mg/dl) and semi-soft contact lenses (13.31 ± 5.43 mg/dl). A significant increase in tear IgA was noticed in subjects wearing lenses for >3 years (15.69 ± 5.39 mg/dl). About 43.4% of lens wearers were symptomatic and 80% of their lenses showed deposits and/or haziness. All cases with IgM in tear were symptomatic. Conclusion: The relation of immunoglobulin concentration with increasing duration of wear and material of contact lens shows that tear immunoglobulin rise accrues due to mechanical stimulation, hence contact lenses should not be used for a long period and lenses of hard nature should be discouraged. The maintenance, cleaning and deproteinization of the lenses are of high importance to avoid immunostimulation. PMID:25667732

  8. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    Science.gov (United States)

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  9. Tearing mode analysis in tokamaks, revisited

    International Nuclear Information System (INIS)

    Nishimura, Y.; Callen, J.D.; Hegna, C.C.

    1997-12-01

    A new Δ' shooting code has been developed to investigate tokamak plasma tearing mode stability in a cylinder and large aspect ratio (ε ≤ 0.25) toroidal geometries, neglecting toroidal mode coupling. A different computational algorithm is used (shooting out from the singular surface instead of into it) to resolve the strong singularities at the mode rational surface, particularly in the presence of finite pressure term. Numerical results compare favorably with Furth et al. results. The effects of finite pressure, which are shown to decrease Δ', are discussed. It is shown that the distortion of the flux surfaces by the Shafranov shift, which modifies the geometry metric element stabilizes the tearing mode significantly, even in a low β regime before the toroidal magnetic curvature effects come into play. Double tearing modes in toroidal geometries are examined as well. Furthermore, m ≥ 2 tearing mode stability criteria are compared with three dimensional initial value MHD simulation by the FAR code

  10. [Effects of acupuncture on lactoferrin content in tears and tear secretion in patients suffering from dry eyes: a randomized controlled trial].

    Science.gov (United States)

    Shi, Jing-lin; Miao, Wan-hong

    2012-09-01

    With the understanding of the immune inflammatory response in the pathogenesis of dry eyes, and the limitations of widely used artificial tears and numerous pharmaceuticals and methods to promote tear secretion, clinicians pay more attention to the therapies that can promote tear secretion actively. Acupuncture treatment for dry eye may meet this requirement. To observe the clinical efficacy of acupuncture treatment on dry eye and the effects on duration, and to examine the mechanisms of acupuncture in treating patients with dye eyes. The study was performed at Department of Ophthalmology, Shuguang Hospital, Shanghai University of Traditional Chinese Medicine from August 2010 to May 2011. Patients with the primary diagnosis of dry eye were enrolled. Sixty-five patients were randomly divided into treatment group and control group, and were given 3 weeks of acupuncture treatment or artificial tear therapy respectively. The enzyme-linked immunosorbent assay was used to detect the lactoferrin content of the tears before and after treatment. In order to evaluate the efficacy of the treatment methods, the Schirmer I test and break-up time were also measured. Compared with before treatment, the lactoferrin content in the tears of patients in the treatment group increased, break-up time was prolonged and the result of the Schirmer I test showed improvement after 3 weeks of treatment. The indexes mentioned above did not change in the control group after treatment. There were no significant differences in tear lactoferrin and Schirmer I test between one week after treatment and after 3-week treatment in the treatment group, but break-up time was significantly shortened. The result of Schirmer I test in the treatment group was significantly higher than that in the control group one week after treatment. Acupuncture can increase tear lactoferrin level, extend tear film break-up time and promote tear secretion in patients with dry eye in a time-limited trial. With the end of

  11. The imaging of the shoulder joint

    International Nuclear Information System (INIS)

    Hayamizu, Kyoko; Ito, Katsuhide; Naito, Akira

    1988-01-01

    Computed tomographic arthrography (arthro-CT) and rotator cuff sonography (RC-US) are new methods for investigating cases with shoulder disorders. We present details of these techniques and report normal and pathological findings of the shoulder joint composed of the glenoid lablum, glenoid, joint capsule and RC. Twenty nine cases with shoulder instability and RC tears were evaluated by arthro-CT. Arthro-CT findings were correlated with surgical ones in three operated cases. Arthro-CT has provided excellent visualizations of labral tears and capsular lesions and has been successfully utilized for detection of the spilled contrast material with RC tears. We examined RC-US in 9 cases who underwent surgery or arthrography on suspicion of rotator cuff tears, and 12 normal volunteers. RC-US findings indicative of the tears included (1) defect or focal thinning of the RC in 3 cases, (2) discontinuity in the homogenous echogenicity of the RC in 2 cases, (3) presence of the abnormal central echogenic band or echogenic foci in the RC in 6 cases. The defect or thinning of the RC represented full-thickness tears. RC-US is a rapid, noninvasive and reliable method of detecting RC tears. (author)

  12. What is the impingement-free range of motion of the asymptomatic hip in young adult males?

    Science.gov (United States)

    Larkin, Brian; van Holsbeeck, Marnix; Koueiter, Denise; Zaltz, Ira

    2015-04-01

    Femoroacetabular impingement is a recognized cause of chondrolabral injury. Although surgical treatment for impingement seeks to improve range of motion, there are very little normative data on dynamic impingement-free hip range of motion (ROM) in asymptomatic people. Hip ultrasound demonstrates labral anatomy and femoral morphology and, when used dynamically, can assist in measuring range of motion. The purposes of this study were (1) to measure impingement-free hip ROM until labral deflection is observed; and (2) to measure the maximum degree of sagittal plane hip flexion when further flexion is limited by structural femoroacetabular abutment. Forty asymptomatic adult male volunteers (80 hips) between the ages of 21 and 35 years underwent bilateral static and dynamic hip ultrasound examination. Femoral morphology was characterized and midsagittal flexion passive ROM was measured at two points: (1) at the initiation of labral deformation; and (2) at maximum flexion when the femur impinged on the acetabular rim. The mean age of the subjects was 28 ± 3 years and the mean body mass index was 25 ± 4 kg/m(2). Mean impingement-free hip passive flexion measured from full extension to initial labral deflection was 68° ± 17° (95% confidence interval [CI], 65-72). Mean maximum midsagittal passive flexion, measured at the time of bony impingement, was 96° ± 6° (95% CI, 95-98). Using dynamic ultrasound, we found that passive ROM in the asymptomatic hip was much less than the motion reported in previous studies. Measuring ROM using ultrasound is more accurate because it allows anatomic confirmation of terminal hip motion. Surgical procedures used to treat femoroacetabular impingement are designed to restore or increase hip ROM and their results should be evaluated in light of precise normative data. This study suggests that normal passive impingement-free femoroacetabular flexion in the young adult male is approximately 95°.

  13. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    Science.gov (United States)

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  14. Relationships between rotator cuff tear types and radiographic abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying [Dept. of Diagnostic Radiology, College of Medicine, Chungbuk National University, Cheongju (Korea, Republic of)

    2014-11-15

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  15. Relationships between rotator cuff tear types and radiographic abnormalities

    International Nuclear Information System (INIS)

    Lee, Soo Hyun; Chun, Kyung Ah; Lee Soo Jung; Kang, Min Ho; Yi, Kyung Sik; Zhang, Ying

    2014-01-01

    To determine relationships between different types of rotator cuff tears and radiographic abnormalities. The shoulder radiographs of 104 patients with an arthroscopically proven rotator cuff tear were compared with similar radiographs of 54 age-matched controls with intact cuffs. Two radiologists independently interpreted all radiographs for; cortical thickening with subcortical sclerosis, subcortical cysts, osteophytes in the humeral greater tuberosity, humeral migration, degenerations of the acromioclavicular and glenohumeral joints, and subacromial spurs. Statistical analysis was performed to determine relationships between each type of rotator cuff tears and radiographic abnormalities. Inter-observer agreements with respect to radiographic findings were analyzed. Humeral migration and degenerative change of the greater tuberosity, including sclerosis, subcortical cysts, and osteophytes, were more associated with full-thickness tears (p < 0.01). Subacromial spurs were more common for full-thickness and bursal-sided tears (p < 0.01). No association was found between degeneration of the acromioclavicular or glenohumeral joint and the presence of a cuff tear. Different types of rotator cuff tears are associated with different radiographic abnormalities.

  16. Meniscus tears of the knee: Postarthrogram high resolution CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Do, Young Soo; You, Jin Jong; Gong, Jae Chul; Kim, Hyung Jin; Chung, Sung Hoon

    1990-01-01

    Thirty-eight knees with clinically suspected meniscal tears were examined with high resolution computed tomography(HRCT) immediately following double contrast arthrography. All subsequently underwent arthroscopy. The findings of postarthrogram HRCT and arthroscopy were compared to evaluated the usefulness of postarthrogram HRCT in diagnosis of the meniscal tears. The sensitivity, specificity and accuracy of HRCT were 96.2%. 83.3% and 92.1% respectively. The anatomic details of the meniscal tears were clearly visible on the HRCT scans. Sagittal and coronal reformation views well visualized the horizontal tears and the relationship of torn meniscal fragments, and well differential the peripheral tears from the synovial recess. Our result indicate that postarthrogram HRCT not only is a sensitive and effective method for the detection and characterization of the meniscal tears, but also provides arthroscopists with the appropriate surgical plans

  17. Tear film measurement by optical reflectometry technique

    Science.gov (United States)

    Lu, Hui; Wang, Michael R.; Wang, Jianhua; Shen, Meixiao

    2014-01-01

    Abstract. Evaluation of tear film is performed by an optical reflectometer system with alignment guided by a galvanometer scanner. The reflectometer system utilizes optical fibers to deliver illumination light to the tear film and collect the film reflectance as a function of wavelength. Film thickness is determined by best fitting the reflectance-wavelength curve. The spectral reflectance acquisition time is 15 ms, fast enough for detecting film thickness changes. Fast beam alignment of 1 s is achieved by the galvanometer scanner. The reflectometer was first used to evaluate artificial tear film on a model eye with and without a contact lens. The film thickness and thinning rate have been successfully quantified with the minimum measured thickness of about 0.3 μm. Tear films in human eyes, with and without a contact lens, have also been evaluated. A high-contrast spectral reflectance signal from the precontact lens tear film is clearly observed, and the thinning dynamics have been easily recorded from 3.69 to 1.31 μm with lipid layer thickness variation in the range of 41 to 67 nm. The accuracy of the measurement is better than ±0.58% of the film thickness at an estimated tear film refractive index error of ±0.001. The fiber-based reflectometer system is compact and easy to handle. PMID:24500519

  18. Magnetic resonance findings in skeletal muscle tears

    International Nuclear Information System (INIS)

    De Smet, A.A.

    1993-01-01

    Magnetic resonance (MR) images of skeletal muscle tears can clearly delineate the severity of muscle injury. Although MR imaging is seldom necessary in patients with acute musle trauma, it can be helpful in deciding on clinical management. The two major MR findings in acute muscle tears are deformity of the muscle and the presence of abnormal signal reflecting hemorrhage and edema. In acute tears, methemoglobin within the extravascular blood causes high-signal areas on both T1- and T2-weighted images. With partial tears, the blood may dissect in a distinctive linear pattern along the muscle bundles and fibers. As healing begins, the muscle signal diminishes, first on the T1-weighted images and then on the T2-weighted images. When there is residual abnormal signal on images obtained more than several months after the injury, it is presumed to represent hemorrhage from recurrent tears. In patients with a questionable history of a remote injury, the clinical presentation may be that of persistent pain or a soft tissue mass. In these cases MR imaging may identify the cause of the pain and can exclude a neoplasm by proving that the mass is a hypertrophied or retracted musle. Thus, MR imaging has a limited, but occasionally important role in selected patients with skeletal muscle tears. (orig.)

  19. Superior glenoid inclination and rotator cuff tears.

    Science.gov (United States)

    Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z

    2018-03-23

    The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Surgical treatment of isolated aseptic acetabular loosening of the hip joint

    Directory of Open Access Journals (Sweden)

    Zvereva К.Р.

    2017-09-01

    Full Text Available Aseptic acetabular loosening is one of the most common complications of primary hip arthroplasty Its treatment is possible in the volume of replacement of only the endoprosthesis cup with the preservation of a stable correctly oriented femoral component. The sequence of actions consists of provision of access to the acetabulum component and its replacement, after which the necessary offset is selected by changing the size of the head and installing a new pair of friction. Currently, the vast majority of the installed heads during the primary and revision hip replacement have a standard size forthe cone of the femoral component 12/14mm. According to the observations, in 3% of cases, there are femoral components with non-standard cone sizes 11/13 mm, usually established 7-8 years ago. The absence of heads forthe necessary cone leads to the need to replace the stable correctly oriented femoral component, which is accompanied by an increase in the time of intervention, the volume of intraoperative blood loss and the risk of intraopera-tive peri-prosthetic fracture. We represent the clinical case of a 75-year-old patient with a dislocation of the acetabular component and a stable correctly oriented femoral component, which during the audit intervention due to the lack of heads for an irregular cone size, total replacement of the components was made.

  1. Electrostatic effect for the collisionless tearing mode

    International Nuclear Information System (INIS)

    Hoshino, M.

    1987-01-01

    Electron dynamics has not been self-consistently considered in collisionless tearing mode theories to date because of the mathematical complexity of the Vlasov-Maxwell equations. We have found using computer simulations that electrostatic fields play an important role in the tearing mode. Vlasov theory, including the electrostatic field, is investigated for topologies with both antiparallel and nonantiparallel magnetic field lines. The electrostatic field influences the resonant current in the neutral sheet which is a non-MHD effect, and modifies the linear growth rate. At the magnetopause, where the field lines are not antiparallel, the electrostatic effect acts to raise the linear growth rate of the tearing mode. On the other hand, in the magnetotail, where magnetic field lines are antiparallel, the electrostatic effect reduces the tearing mode growth rate. copyright American Geophysical Union 1987

  2. Spectral-domain optical coherence tomography study on dynamic changes of human tears after instillation of artificial tears.

    Science.gov (United States)

    Napoli, Pietro Emanuele; Satta, Giovanni Maria; Coronella, Franco; Fossarello, Maurizio

    2014-07-01

    To analyze in vivo the dynamic changes induced by different artificial tears (ATs) in the precorneal tear film (PCTF) and lower tear meniscus (LTM) by using spectral-domain (SD) anterior segment optical coherence tomography (OCT). We prospectively examined 42 normal human eyes by using SD-OCT imaging. On the day before OCT imaging, all enrolled subjects were evaluated for abnormalities of ocular surface. All tear film images were obtained before and after instillation of three different types of ATs (mucomimetic, lipid-based, and saline) in five serial scans: immediately (within 30 seconds), at the first, fifth, 10th, and 20th minute. Subjects received a drop of 35 μL in one randomly selected eye. All examinations were conducted in the same conditions of temperature, brightness, humidity, and time of day. Changes in the morphological pattern of both LTM and PCTF were associated with the type of artificial tear instilled on the ocular surface. Similarly, the radius of curvature (rc), the height (h), and the depth (d) showed dynamic variations depending on treatment. Although by the 20th minute, both h and d returned to baseline values in all groups, a significant difference in rc (compared with baseline) was detected for mucomimetic ATs (P = 0.04) and lipid ATs (P = 0.02). Spectral-domain OCT imaging has preliminarily proved to be a noninvasive tool to evaluate, in real time, the different changes induced by ATs instillation. An important stride in understanding the clinical response to various tear substitutes can be achieved by this objective and quantitative approach. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  3. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    Science.gov (United States)

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  4. A case of recurrent bloody tears

    Directory of Open Access Journals (Sweden)

    Karslıoğlu Ş

    2011-07-01

    Full Text Available Şafak Karslioğlu1, Ilke Bahçeci Şimşek2, Müslime Akbaba11Ìstanbul Oculoplastic and Orbital Surgery and Ocular Oncology Center, 2Ophthalmology Department, Medicine Hospital, Ìstanbul, TurkeyAbstract: Well-known causes of blood-tinged epiphora are conjunctival lesions, tumors of the lacrimal apparatus, and systemic bleeding disorders. We describe an unusual patient who presented with recurrent episodes of bloody tearing which began following an erythema multiforme-like drug eruption. He experienced chronic conjunctivitis which resulted in a few minor symblephara. One year later, the patient developed attacks of bloody tearing. All clinical, radiologic, and laboratory investigations related to bloody epiphora were within normal limits except for a mild, nonspecific chronic inflammatory reaction in the perivascular tissues of the lacrimal gland and orbital soft tissues. Also, an increase in vascular permeability and contrast extravasation on carotid angiography was detected. High-dose vitamin C was administered. The patient continued to have unilateral bloody tears intermittently for two years, but the episodes became much less frequent and had resolved by three years. It is conceivable that increased vascular permeability following the systemic inflammatory process could have played a role in the etiology of recurrent bloody tears in this atypical patient.Keywords: bloody tears, erythema multiforme, drug eruption, vitamin C

  5. Sonographic Visualization of the Rotator Cable in Patients With Symptomatic Full-Thickness Rotator Cuff Tears: Correlation With Tear Size, Muscular Fatty Infiltration and Atrophy, and Functional Outcome.

    Science.gov (United States)

    Bureau, Nathalie J; Blain-Paré, Etienne; Tétreault, Patrice; Rouleau, Dominique M; Hagemeister, Nicola

    2016-09-01

    To assess the prevalence of sonographic visualization of the rotator cable in patients with symptomatic full-thickness rotator cuff tears and asymptomatic controls and to correlate rotator cable visualization with tear size, muscular fatty infiltration and atrophy, and the functional outcome in the patients with rotator cuff tears. Fifty-seven patients with rotator cuff tears and 30 asymptomatic volunteers underwent shoulder sonography for prospective assessment of the rotator cable and rotator cuff tear and responded to 2 functional outcome questionnaires (shortened Disabilities of the Arm, Shoulder, and Hand [QuickDASH] and Constant). In the patients with rotator cuff tears, appropriate tests were used to correlate rotator cable visualization with the tear size, functional outcome, muscular fatty infiltration, and atrophy. The patients with rotator cuff tears included 25 women and 32 men (mean age,57 years; range, 39-67 years), and the volunteers included 13 women and 17 men (mean age, 56 years; range, 35-64 years). The rotator cable was identified in 77% (23 of 30) of controls and 23% (13 of 57) of patients with rotator cuff tears. In the patients, nonvisualization of the rotator cable correlated with larger tears (P tears than asymptomatic controls and was associated with a larger tear size and greater supraspinatus fatty infiltration and atrophy. Diligent assessment of the supraspinatus muscle should be done in patients with rotator cuff tears without a visible rotator cable, as the integrity of these anatomic structures may be interdependent.

  6. ProTec Tear-Offs: A Preliminary Assessment

    International Nuclear Information System (INIS)

    Peeler, D

    2005-01-01

    The Savannah River National Laboratory (SRNL) has conducted a series of ''scoping'' tests (referred to as Phase 1) to assess the potential use of a Mylar(reg s ign) tear-off system as a primary or secondary protective barrier to minimize acid etching (''frosting''), accidental scratching, and/or radiation damage for shielded cells windows. Conceptually, thin, multi-layered sheets of Mylar (referred to as a ''tear-off'' system) could be directly applied to the Lexan(reg s ign) sheet or glovebox/hood sash window to serve as a secondary (or primary) barrier. Upon degradation of visual clarity due to accidental scratching, spills/splatters, and/or radiation damage, the outer layer (or sheet) of Mylar could be removed ''refreshing'' or restoring the view. Due to the multi-layer aspect, the remaining Mylar layers would provide continued protection for the window from potential reoccurrences (which could be immediate or after some extended time period). Although the concept of using a tear-off system as a protective barrier was conceptually enticing, potential technical issues were identified and addressed as part of this Phase 1 feasibility study. These included resistance to: (1) acid(s) (concentrated (28.9 M) HF, concentrated (15.9M) HNO 3 , 6M HCl, and 0.6M H 3 BO 3 ), (2) base (a simulated sludge with pH of 12.9), (3) gamma radiation (cumulative dose of ∼200,000 rad), and (4) scratch resistance (simulating accidental scratching with the manipulators). Not only can these four factors play a significant role in determining the visual clarity of the integrated system, they can also contribute to the mechanical integrity issues which could dictate the ability to remove the outer layer when visual clarity has degraded. The results of the Phase 1 study clearly indicate that the Mylar tear-off concept (as a primary or secondary protective barrier) is a potential technical solution to prevent or retard excessive damage that would result from acid etching, base damage (as a

  7. Posterior meniscus root tears: associated pathologies to assist as diagnostic tools.

    Science.gov (United States)

    Matheny, Lauren M; Ockuly, Andrew C; Steadman, J Richard; LaPrade, Robert F

    2015-10-01

    The purpose of this study was to investigate associated pathologies identified at arthroscopy in patients with meniscus root tears. This study was Institutional Review Board approved. All patients who underwent arthroscopic knee surgery where a complete meniscus root tear was identified were included in this study. Concurrent ligament tears and articular cartilage changes ≥Outerbridge grade 2 were recorded and stored in a data registry. Fifty patients (28 males, 22 females) [mean age = 36.5 years (range 17.1-68.1 years)] who were diagnosed with a medial or lateral meniscus root tear at arthroscopy were included in this study out of 673 arthroscopic surgeries (prevalence 7.4 %). Twenty-three (46 %) patients had a medial meniscus root tear, 26 (52 %) patients had a lateral meniscus root tear and one (2 %) patient had both. Thirty-four per cent of patients (n = 17) underwent partial meniscectomy, while 60 % (n = 31) underwent suture repair. During arthroscopy, 60 % (n = 30) of patients were diagnosed with an anterior cruciate ligament (ACL) tear. Patients with lateral meniscus root tears were 10.3 times (95 % CI 2.6-42.5) more likely to have ACL tears than patients with medial meniscus root tears (p = 0.012). Patients who had medial meniscus root tears were 5.8 times (95 % CI 1.6-20.5) more likely to have chondral defects than patients who had lateral meniscus root tears (p = 0.044). In this study, patients' preoperative functional scores and activity levels were low. Patients with lateral meniscal root tears were more likely to have an ACL tear. Patients with medial meniscal root tears were more likely to have an knee articular cartilage defect with an Outerbridge grade 2 or higher chondral defect. This study confirms the importance of comprehensive assessment of concurrent injuries to properly diagnose meniscus root tears. IV.

  8. Percutaneous Fixation of Anterior Column Acetabular Fracture in a Renal Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Halil Ceylan

    2013-01-01

    Full Text Available Renal transplantation, performed per million population, ranges from 30 to 60 in developed countries. The transplanted kidney is generally placed in iliac fossa; therefore the treatment procedure of the pelvic trauma in these patients should be selected carefully. The gold standard technique for the treatment of displaced acetabulum fractures is open reduction and internal fixation. Our patient had received a living-related-donor renal transplant due to chronic renal failure. In the second year of transplantation, she had been injured in a motor-vehicle accident, and radiographs showed a right acetabular anterior column fracture and left pubic rami fractures. The patient was treated with percutaneous fixation techniques and at one year of postoperative period there was no evidence of degenerative signs and the clinical outcome was good. Beside having the advantage of avoiding dissection through the iliac fossa by the standard ilioinguinal approach, percutaneous techniques, with shorter surgical time, decreasing soft tissue disruption, and the potential for early discharge from hospital might be ideal for a renal transplant recipient carrying a higher risk of infection. Percutaneous fixation of selected acetabular fractures in a renal transplant recipient would presumably have the potential to decrease the morbidity associated with traditional open surgical procedures.

  9. Tear ferning in normal dogs and dogs with keratoconjunctivitis sicca ...

    African Journals Online (AJOL)

    This study evaluates tear ferning as an ancillary technique for the evaluation of the canine tear film in normal eyes and eyes affected by keratoconjunctivitis sicca (KCS). Thirty dogs with KCS and 50 control dogs with normal tear film were evaluated with a full ophthalmoscopic examination and a Schirmer tear test type 1 ...

  10. Acetabular reconstruction with human and bovine freeze-dried bone grafts and a reinforcement device

    Directory of Open Access Journals (Sweden)

    Ricardo Rosito

    2008-01-01

    Full Text Available BACKGROUND: This is a cohort trial (1997-2005 of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG and a reinforcement device. OBJECTIVE: To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS: There were two groups: I (n=26 receiving human grafts and II (n=25 receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d'Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn's et al. criteria for radiographic bone incorporation. RESULTS: No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424. CONCLUSION: The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty.

  11. Readability of the Most Commonly Accessed Arthroscopy-Related Online Patient Education Materials.

    Science.gov (United States)

    Akinleye, Sheriff D; Krochak, Ryan; Richardson, Nicholas; Garofolo, Garret; Culbertson, Maya Deza; Erez, Orry

    2018-04-01

    To assess the readability and comprehension of written text by the most commonly visited websites containing patient education materials on common conditions that can be treated arthroscopically. We examined 50 websites, assessed independently by 2 orthopaedic surgery residents (S.A. and G.G.), with educational materials on 5 common conditions treated by arthroscopic surgeons: anterior cruciate ligament (ACL) tear, meniscus tear, hip labral tear, shoulder labral tear, and rotator cuff tear. Following a Google search for each condition, we analyzed the 10 most visited websites for each disorder using a widely used and validated tool for assessing the reading levels of written materials (Flesch-Kincaid formula). The average grade reading level of the 50 websites studied was 9.90 with a reading ease of 52.14 ("fairly difficult, high school"). Only 26% of the websites were at or below the national average of an eighth-grade reading level. Of the 5 conditions treated by arthroscopic surgery, ACL tear had the highest average grade reading level at 10.73 ± 1.54, whereas meniscus tear had the lowest at 9.31 ± 1.81. Every condition in this study had an average readability at or above the ninth-grade reading level. The most frequently accessed materials for patients with injuries requiring arthroscopic surgery exceeds the readability recommendations of the American Medical Association and National Institutes of Health, as well as the average reading ability of US adults. Given the fact that these are the most commonly visited websites by the lay public, there needs to be a greater emphasis on tailoring written information to the literacy levels of the patient population. This study emphasizes the discrepancy between the recommended versus the measured reading levels of online patient education materials related to conditions treated by arthroscopic surgeons. The subject matter of these conditions is inherently complex; thus, relying solely on text to inform patients

  12. Forced tearing of ductile and brittle thin sheets.

    Science.gov (United States)

    Tallinen, T; Mahadevan, L

    2011-12-09

    Tearing a thin sheet by forcing a rigid object through it leads to complex crack morphologies; a single oscillatory crack arises when a tool is driven laterally through a brittle sheet, while two diverging cracks and a series of concertinalike folds forms when a tool is forced laterally through a ductile sheet. On the other hand, forcing an object perpendicularly through the sheet leads to radial petallike tears in both ductile and brittle materials. To understand these different regimes we use a combination of experiments, simulations, and simple theories. In particular, we describe the transition from brittle oscillatory tearing via a single crack to ductile concertina tearing with two tears by deriving laws that describe the crack paths and wavelength of the concertina folds and provide a simple phase diagram for the morphologies in terms of the material properties of the sheet and the relative size of the tool.

  13. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Ishibashi, Masanori

    1997-01-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  14. Analysis of the acetabulum by CT scan in Japanese with osteoarthritis of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Masanori [Keio Univ., Tokyo (Japan). School of Medicine

    1997-11-01

    The morphology of the acetabulum was analyzed by CT scan in 66 Japanese patients with osteoarthritis of the hip mainly following congenital dislocation or dysplasia. The CT scan data was analyzed to standardize the pelvic inclination in all directions. In these patients, the acetabular floor had thickened and the acetabulum was located in the anterolateral portion. The bilateral difference in the acetabular anteversion angle was not different between patients and normal individuals, but the acetabular sector angle in patients was smaller than in the normal subjects. As the stage of osteoarthritis of the hip advanced, the thickness of the acetabular floor in the center and posterior portions and the anterior sector angle increased, and the lateralization of the acetabulum advanced, but the anteversion angle decreased. A bone-forming change is characteristic of the anterior acetabulum and acetabular fossa in the center and posterior portions in Japanese patients with osteoarthritis of the hip. In comparison with data obtained by standard radiography, these changes detected by CT scan corresponded to an increase of the width of a tear drop, the lateralization of the femoral head and the lack of the support of the femoral head from the acetabulum. (author)

  15. Assessment and treatment strategies for rotator cuff tears

    Science.gov (United States)

    Al-Hakim, Wisam; Noorani, Ali

    2014-01-01

    Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960

  16. Tear function and ocular surface after Muller muscle-conjunctival resection.

    Science.gov (United States)

    Uğurbaş, Suat Hayri; Alpay, Atilla; Bahadır, Burak; Uğurbaş, Sılay Cantürk

    2014-05-01

    Muller muscle-conjunctival resection (MCR) is a surgical technique to correct mild and moderate ptosis. In this study, tear function tests and ocular surface are evaluated in patients who underwent unilateral surgery. Sixteen patients with normal preoperative tear function who underwent unilateral MCR were evaluated prospectively. The fellow eyes of the patients were taken as the control group. A dry eye assessment questionnaire, Schirmer testing, tear film break-up time, fluorescein stain, Rose-Bengal stain, and conjunctival impression cytology were used to assess the tear film functions and ocular surface changes in the operated and non-operated eyes. There was no statistically significant difference in the tear function tests and goblet cell densities between the operated and non-operated eyes. The results indicate that an MCR procedure has no apparent effect on tear function tests and goblet cell density in patients with normal preoperative tear function.

  17. Progression of Fatty Muscle Degeneration in Atraumatic Rotator Cuff Tears.

    Science.gov (United States)

    Hebert-Davies, Jonah; Teefey, Sharlene A; Steger-May, Karen; Chamberlain, Aaron M; Middleton, William; Robinson, Kathryn; Yamaguchi, Ken; Keener, Jay D

    2017-05-17

    The purpose of this prospective study was to examine the progression of fatty muscle degeneration over time in asymptomatic shoulders with degenerative rotator cuff tears. Subjects with an asymptomatic rotator cuff tear in 1 shoulder and pain due to rotator cuff disease in the contralateral shoulder were enrolled in a prospective cohort. Subjects were followed annually with shoulder ultrasonography, which evaluated tear size, location, and fatty muscle degeneration. Tears that were either full-thickness at enrollment or progressed to a full-thickness defect during follow-up were examined. A minimum follow-up of 2 years was necessary for eligibility. One hundred and fifty-six shoulders with full-thickness rotator cuff tears were potentially eligible. Seventy shoulders had measurable fatty muscle degeneration of at least 1 rotator cuff muscle at some time point. Patients with fatty muscle degeneration in the shoulder were older than those without degeneration (mean, 65.8 years [95% confidence interval (CI), 64.0 to 67.6 years] compared with 61.0 years [95% CI, 59.1 to 62.9 years]; p tears at baseline was larger in shoulders with degeneration than in shoulders that did not develop degeneration (13 and 10 mm wide, respectively, and 13 and 10 mm long; p Tears with fatty muscle degeneration were more likely to have enlarged during follow-up than were tears that never developed muscle degeneration (79% compared with 58%; odds ratio, 2.64 [95% CI, 1.29 to 5.39]; p muscle degeneration occurred more frequently in shoulders with tears that had enlarged (43%; 45 of 105) than in shoulders with tears that had not enlarged (20%; 10 of 51; p tears with enlargement and progression of muscle degeneration were more likely to extend into the anterior supraspinatus than were those without progression (53% and 17%, respectively; p tear size (p = 0.56). The median time from tear enlargement to progression of fatty muscle degeneration was 1.0 year (range, -2.0 to 6.9 years) for the

  18. Sonographic evaluation of digital annular pulley tears

    International Nuclear Information System (INIS)

    Martinoli, C.; Derchi, L.E.; Bianchi, S.; Garcia, J.F.; Nebiolo, M.

    2000-01-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  19. Sonographic evaluation of digital annular pulley tears

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, C.; Derchi, L.E. [Istituto di Radiologia, Universita di Genova, Genoa (Italy); Bianchi, S.; Garcia, J.F. [Dept. de Radiologie, Hopital Cantonal Universitaire de Geneve (Switzerland); Nebiolo, M. [Reparto Pronto Soccorso Medico, Pietra Ligure (Italy)

    2000-07-01

    Objective. To evaluate the sonographic (US) appearance of digital annular pulley (DAP) tears in high-level rock climbers. Design and patients. We performed a retrospective analysis of the US examinations of 16 high-level rock climbers with clinical signs of DAP lesions. MRI and surgical evaluation were performed in five and three patients respectively. The normal US and MRI appearances of DAP were evaluated in 40 and three normal fingers respectively. Results. Nine of 16 patients presented a DAP tear. In eight subjects (seven with complete tears involving the fourth finger and one the fifth finger), US diagnosis was based on the indirect sign of volar bowstringing of the flexor tendons. Injured pulleys were not appreciated by US. Tears concerned the A2 and A3 in six patients and the A3 and A4 in two patients. A2 pulley thickening and hypoechogenicity compatible with a partial tear was demonstrated in one patient. MRI and surgical data correlated well with the US findings. Four patients had tenosynovitis of the flexor tendons but no evidence of pulley disruption. US examinations of three patients were normal. In the healthy subjects US demonstrated DAP in 16 of 40 digits. Conclusion. US can diagnose DAP tears and correlates with the MRI and surgical data. Because of its low cost and non-invasiveness we suggest US as the first imaging modality in the evaluation of injuries of the digital pulley. (orig.)

  20. Comparative studies of MRI and operative findings in rotator cuff tear

    International Nuclear Information System (INIS)

    Yamakawa, Seigo; Ichikawa, Norikazu; Itadera, Eichi; Hashizume, Hiroyuki; Inoue, Hajime

    2001-01-01

    A prospective study was performed to determine the accuracy of magnetic resonance imaging (MRI) compared with operative findings in the evaluation of patients associated with rotator cuff tears. Fifty-four of 60 shoulders (58 patients) examined by MRI were confirmed as full-thickness tears and 6 as partial-thickness tears at the time of surgery. The oblique coronal, oblique sagittal, and axial planes of T2-weighted images with the 0.5 tesla MRI system were obtained preoperatively and compared with operative findings. MRI correctly identified 46 of 54 full-thickness rotator cuff tears and 5 of 6 partial-thickness tears. A comparison of MRI and operative findings in full-thickness cuff tears showed a sensitivity of 85%, a specificity of 83%, and a positive prospective value (PPV) of 99%. A comparison of partial-thickness tears showed a sensitivity of 83%, a specificity of 85%, and PPV of 39%. Linear regression analysis showed an excellent correlation between the MRI assessment and measurement at the time of surgery (r=0.90, P<0.01). MRI was useful in evaluating large and medium-sized rotator cuff tears, but less useful in distinguishing small full-thickness tears from partial-thickness tears. (author)

  1. Tearing resistance of some co-polyester sheets

    International Nuclear Information System (INIS)

    Kim, Ho Sung; Karger-Kocsis, Jozsef

    2004-01-01

    A three-zone model consisting of initial, evolutionary and stabilised plastic zones for tearing resistance was proposed for polymer sheets. An analysis with the model, based on the essential work of fracture (EWF) approach, was demonstrated to be capable for predicting specific total work of fracture along the tear path across all the plastic zones although accuracy of specific essential work of fracture is subject to improvement. Photo-elastic images were used for identification of plastic deformation sizes and profiles. Fracture mode change during loading was described in relation with the three zones. Tearing fracture behaviour of extruded mono- and bi-layer sheets of different types of amorphous co-polyesters and different thicknesses was investigated. Thick material exhibited higher specific total work of tear fracture than thin mono-layer sheet in the case of amorphous polyethylene terephthalate (PET). This finding was explained in terms of plastic zone size formed along the tear path, i.e., thick material underwent larger plastic deformation than thin material. When PET and polyethylene terephthalate glycol (PETG) were laminated with each other, specific total work of fracture of the bi-layer sheets was not noticeably improved over that of the constituent materials

  2. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    Science.gov (United States)

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  3. Rotator cuff tear measurement by arthropneumotomography

    International Nuclear Information System (INIS)

    Kilcoyne, R.F.; Matsen, F.A. III

    1983-01-01

    Five years of experience with a method of shoulder arthrography using upright tomography in cases of suspected or known rotator cuff tears has demonstrated its effectiveness. The value of the procedure lies in its ability to demonstrate the size of the cuff tear and the thickness of the remaining cuff tissue. This information provides the surgeon with a preoperative estimate of the difficulty of the repair and the prognosis for a good functional recovery. In 33 cases, there was good correlation between the upright thin-section tomogram findings and the surgical results. The tomograms provided better information about the size of the tear and the quality of the remaining cuff than did plain arthrograms

  4. Partial Thickness Rotator Cuff Tears: Current Concepts

    Science.gov (United States)

    Matthewson, Graeme; Beach, Cara J.; Nelson, Atiba A.; Woodmass, Jarret M.; Ono, Yohei; Boorman, Richard S.; Lo, Ian K. Y.; Thornton, Gail M.

    2015-01-01

    Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized. PMID:26171251

  5. Partial Thickness Rotator Cuff Tears: Current Concepts

    Directory of Open Access Journals (Sweden)

    Graeme Matthewson

    2015-01-01

    Full Text Available Partial thickness rotator cuff tears are a common cause of pain in the adult shoulder. Despite their high prevalence, the diagnosis and treatment of partial thickness rotator cuff tears remains controversial. While recent studies have helped to elucidate the anatomy and natural history of disease progression, the optimal treatment, both nonoperative and operative, is unclear. Although the advent of arthroscopy has improved the accuracy of the diagnosis of partial thickness rotator cuff tears, the number of surgical techniques used to repair these tears has also increased. While multiple repair techniques have been described, there is currently no significant clinical evidence supporting more complex surgical techniques over standard rotator cuff repair. Further research is required to determine the clinical indications for surgical and nonsurgical management, when formal rotator cuff repair is specifically indicated and when biologic adjunctive therapy may be utilized.

  6. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    Science.gov (United States)

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.

  7. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    Science.gov (United States)

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  8. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    LENUS (Irish Health Repository)

    Kelly, M E

    2013-03-13

    BACKGROUND: Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. AIM: To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. METHODS: Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. RESULTS: 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. CONCLUSION: Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient".

  9. Cemental tear: To know what we have neglected in dental practice

    Directory of Open Access Journals (Sweden)

    Po-Yuan Jeng

    2018-04-01

    Full Text Available Cemental tear is a special kind of root surface fracture, contributing to periodontal and periapical breakdown. However, it is a challenge for doctors to diagnose, resulting in delayed or improper treatment. We reviewed the predisposing factors, location, radiographic/clinical characteristics, diagnosis and treatments of cemental tears. From the literature, patients with cemental tear were mainly males, over 60 year-old. Possible predisposing factors include gender, age, tooth type, traumatic occlusal force and vital teeth. Cemental tears were common in upper and lower anterior teeth, single or multiple, and can be present in cervical, middle and apical third of roots. Morphology of cemental tears can be either piece-shaped or U-shaped. Clinically, cemental tear shows a unitary periodontal pocket and signs/symptoms mimicking localized periodontitis, apical periodontitis and vertical root fractures. Treatment of cemental tears include scaling, root planning, root canal treatment, periodontal/periapical surgery, guided tissue regeneration, bone grafting, and intentional replantation. Recurrence of cemental tear is possible especially when the fracture involves root apex. Extraction is recommended for teeth with poor prognosis. In conclusion, cemental tears can involve both periodontal and periapical area. Dentists should understand the predisposing factors and clinical features of cemental tears for early diagnosis/treatment to prevent bone loss/tooth extraction. Keywords: Cemental tear, Clinical characteristics, Surface root fracture, Periodontal/periapical breakdown, Recurrence, Predisposing factors

  10. Effects of Titanium Mesh Surfaces-Coated with Hydroxyapatite/β-Tricalcium Phosphate Nanotubes on Acetabular Bone Defects in Rabbits

    Directory of Open Access Journals (Sweden)

    Thuy-Duong Thi Nguyen

    2017-07-01

    Full Text Available The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05. CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo.

  11. MR imaging of the traumatic triangular fibrocartilaginous complex tear

    Science.gov (United States)

    Griffith, James F.; Fung, Cindy S. Y.; Lee, Ryan K. L.; Tong, Cina S. L.; Wong, Clara W. Y.; Tse, Wing Lim; Ho, Pak Cheong

    2017-01-01

    Triangular fibrocartilage complex is a major stabilizer of the distal radioulnar joint (DRUJ). However, triangular fibrocartilage complex (TFCC) tear is difficult to be diagnosed on MRI for its intrinsic small and thin structure with complex anatomy. The purpose of this article is to review the anatomy of TFCC, state of art MRI imaging technique, normal appearance and features of tear on MRI according to the Palmar’s classification. Atypical tear and limitations of MRI in diagnosis of TFCC tear are also discussed. PMID:28932701

  12. Profundization of acetabular cup uncemented in total substitution of hip in-patient with acetabular dysplasia - Experience university hospital - Clinica San Rafael

    International Nuclear Information System (INIS)

    Dimian Mayorga, Omar David; Sandoval Daza, Alejandro; Vargas Turriago, Marcela; Perez Torres, Javier

    2005-01-01

    14 patients with acetabular dysplasia were treated at Hospital Universitario Clinica San Rafael with total hip arthroplasty with uncemented cup internization. According to Crowe classification, one was type 1, eight were type 2 and five were type 3. The average follow up was twenty-four months. The Harris hip score was used for the clinical evaluation with a pre operative average of 35 points and 37 points post operative. The average cup internization was four millimeters, with an average cup protrutio of 47% and an average of cup coverage of 81%. The average internization of the femoral head's center was 26mm. screws for cup fixation were used in 3 patients. We did not have complications nor implant revision at the time of follow up

  13. Accuracy of MR imaging in partial tears of rotator cuff

    International Nuclear Information System (INIS)

    Eto, Masao; Ito, Nobuyuki; Tomonaga, Tadashi; Harada, Shin'ichi; Rabbi, M.E.; Iwasaki, Katsuro

    1997-01-01

    MRI is very useful for the diagnosis of the rotator cuff tear However. in case of partial tears it is sometimes controvertible. In this study, we studied the accuracy of MRI in the diagnosis of partial tears. 67 patients who underwent MRI investigation before operation were chosen for this study. There were 61 males and 6 females, ranging from 30 to 80 years (mean: 54.8 years at the time of operation). MRI was performed with 1.5T superconductive system with shoulder surface coil. MPGR T2-weighted images were performed in the coronal oblique and sagittal oblique planes. Complete tears were diagnosed when full thickness high intensity was observed in the rotator cuff, whereas with partial high intensity of the rotator cuff, was considered as partial tears. MRI demonstrated 77.8% sensitivity, 91.4% specificity and 89.6% accuracy in the diagnosis of partial tear. In 8 cases MRI had misinterpretation. In MPGR T2-weighted images, not only the partial tears but the degenerative changes also show high intensity of the rotator cuff. Therefore, it is difficult to differentiate and maybe this is the reason of misinterpretations of partial tears by MRI. MRI provided with useful pre-operative informations of partial tears of the rotator cuff. However, in few cases it is hard to differentiate for the degenerative changes of the rotator cuff. (author)

  14. Instability threshold of neoclassical tearing mode, double tearing mode and off-axis sawteeth crash in tokamaks

    International Nuclear Information System (INIS)

    Li, D.

    2001-01-01

    The neoclassical and double tearing modes have been analyzed with related new phenomena in the reversed magnetic shear tokamak plasmas. The instability threshold, and the linear and nonlinear evolution are derived for the neoclassical tearing modes. It is found that the perturbed bootstrap current in the resistive layer has a stabilizing effect while the equilibrium bootstrap current in the outer region can destabilize the modes. The dispersion relation is derived for the double tearing mode. It is found that the onset of ''annular crash'' is due to the fast reconnection of the hot and cold islands, triggered by the interaction of both branches. The onset of ''core crash'' is mainly due to the coalescence between the hot islands, triggered by the explosive growth of the inner branch. (author)

  15. Instability threshold of neoclassical tearing mode, double tearing mode and off-axis sawteeth crash in tokamaks

    International Nuclear Information System (INIS)

    Li Ding

    1999-01-01

    The neoclassical and double tearing modes have been analyzed with related new phenomena in the reversed magnetic shear tokamak plasmas. The instability threshold, and the linear and nonlinear evolution are derived for the neoclassical tearing modes. It is found that the perturbed bootstrap current in the resistive layer has a stabilizing effect while the equilibrium bootstrap current in the outer region can destabilize the modes. The dispersion relation is derived for the double tearing mode. It is found that the onset of 'annular crash' is due to the fast reconnection of the hot and cold islands, triggered by the interaction of both branches. The onset of 'core crash' is mainly due to the coalescence between the hot islands, triggered by the explosive growth of the inner branch. (author)

  16. Ketofol for monitored anesthesia care in shoulder arthroscopy and labral repair: a case report

    Directory of Open Access Journals (Sweden)

    Lee KC

    2016-06-01

    Full Text Available Kevin C Lee,1 Hanyuan Shi,2 Brian C Lee3 1Columbia University College of Dental Medicine, New York, NY, 2Vanderbilt University School of Medicine, Nashville, TN, 3Department of Anesthesiology, Columbia University Medical Center, New York, NY, USA Abstract: A 21-year-old male (body mass index: 28.3 with a history of asthma and reactive airway disease since childhood underwent left shoulder arthroscopy and labral repair surgery under monitored anesthesia care. Because the procedure was performed in the beach chair position, access to the patient’s airway was limited throughout. To avoid general anesthesia and to limit potential complications associated with monitored anesthesia care, a ketofol admixture was used. This case demonstrates that, in conjunction with regional anesthesia, ketofol may be an acceptable alternative to propofol for maintenance in outpatient orthopedic procedures. Keywords: ketamine, propofol, ketofol, sedation, case report

  17. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon [University of Ulsan, College of Medicine, Department of Radiology, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of); Lee, Man Ho [Andong Medical Center, Department of Radiology, Andong-si, Gyeongsangbuk-do (Korea, Republic of); Lee, Ki Won [University of Ulsan, College of Medicine, Department of Orthopedic Surgery, Asan Foundation, Gangneung Asan Hospital, Gangneung-si, Gangwon-do (Korea, Republic of)

    2016-12-15

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  18. Diagnostic accuracy of 3T conventional shoulder MRI in the detection of the long head of the biceps tendon tears associated with rotator cuff tendon tears

    International Nuclear Information System (INIS)

    Lee, Ro Woon; Choi, Soo-Jung; Ahn, Jae Hong; Shin, Dong Rock; Kang, Chae Hoon; Lee, Man Ho; Lee, Ki Won

    2016-01-01

    To evaluate the diagnostic performance (DP) of 3T (3 Tesla field strength) conventional shoulder magnetic resonance imaging (MRI) in detecting the long head of the biceps tendon (LHBT) tears in association with rotator cuff tendon tears. This study included 80 consecutive patients who underwent arthroscopic surgery for rotator cuff tendon tears. Two radiologists independently evaluated the preoperative 3T shoulder MRI for the presence of LHBT tears. The DP of MRI was evaluated using the results of arthroscopy as the reference standard. We also evaluated the DP of several MR signs of LHBT in detection of partial LHBT tears. Arthroscopic examination revealed 35 partial and 5 complete tears. According to the results of evaluation by reviewers 1 and 2, shoulder MRI exhibited sensitivities of 77.14 and 80 % and specificities of 71.11 and 73.33 % in detection of partial LHBT tears and sensitivities of 80 and 100 % and a specificity of 100% (both) in detection of complete LHBT tears. In detecting partial LHBT tears, increased T2 signal intensity of the LHBT exhibited high sensitivities (reviewers 1 and 2; 82.85 and 80 %, respectively) and the presence of intratendinous defects or C-signs exhibited the highest specificities (reviewers 1 and 2; 95.55 and 93.33 %, respectively), followed by abnormalities in shape and outer margins of the LHBT (reviewers 1 and 2; 91.11 and 82 %; 91.11 and 86.66 %, respectively). Non-contrast-enhanced 3T shoulder MRI is potentially highly accurate in detection of complete LHBT tears, but moderately accurate in detection of partial LHBT tears. (orig.)

  19. Surface tearing modes in tokamaks

    International Nuclear Information System (INIS)

    Takizuka, Tomonori; Kurita, Gen-ichi; Azumi, Masafumi; Takeda, Tatsuoki

    1985-10-01

    Surface tearing modes in tokamaks are studied numerically and analytically. The eigenvalue problem is solved to obtain the growth rate and the mode structure. We investigate in detail dependences of the growth rate of the m/n = 2/1 resistive MHD modes on the safety factor at the plasma surface, current profile, wall position, and resistivity. The surface tearing mode moves the plasma surface even when the wall is close to the surface. The stability diagram for these modes is presented. (author)

  20. Porous metal revision shells for management of contained acetabular bone defects at a mean follow-up of six years: a comparison between up to 50% bleeding host bone contact and more than 50% contact.

    Science.gov (United States)

    Sternheim, A; Backstein, D; Kuzyk, P R T; Goshua, G; Berkovich, Y; Safir, O; Gross, A E

    2012-02-01

    We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years' follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth.

  1. Haemolacria (bloody tears)

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2014-08-06

    Aug 6, 2014 ... menstruation, drugs, hyperthyroidism, nasolacrimal tu- berculosis ... no bleeding from any other body orifice. However ... All age groups can be affected from infancy to ... the system and thus lead to bloody tears emerging from.

  2. Nonlinear drift tearing mode

    International Nuclear Information System (INIS)

    Zelenyj, L.M.; Kuznetsova, M.M.

    1989-01-01

    Nonlinear study of magnetic perturbation development under single-mode conditions in collision-free plasma in configurations with the magnetic field shear is investigated. Results are obtained with regard of transverse component of electrical field and its effect on ion dynamics within wide range of ion Larmor radius value and values of magnetic field shear. Increments of nonlinear drift tearing mode are obtained and it is shown that excitation drastic conditions of even linearly stable modes are possible. Mechanism of instability nonlinear stabilization is considered and the value of magnetic island at the saturation threshold is estimeted. Energy of nonlinear drift tearing mode is discussed

  3. Rotator cuff tears: An evidence based approach

    Science.gov (United States)

    Sambandam, Senthil Nathan; Khanna, Vishesh; Gul, Arif; Mounasamy, Varatharaj

    2015-01-01

    Lesions of the rotator cuff (RC) are a common occurrence affecting millions of people across all parts of the globe. RC tears are also rampantly prevalent with an age-dependent increase in numbers. Other associated factors include a history of trauma, limb dominance, contralateral shoulder, smoking-status, hypercholesterolemia, posture and occupational dispositions. The challenge lies in early diagnosis since a high proportion of patients are asymptomatic. Pain and decreasing shoulder power and function should alert the heedful practitioner in recognizing promptly the onset or aggravation of existing RC tears. Partial-thickness tears (PTT) can be bursal-sided or articular-sided tears. Over the course of time, PTT enlarge and propagate into full-thickness tears (FTT) and develop distinct chronic pathological changes due to muscle retraction, fatty infiltration and muscle atrophy. These lead to a reduction in tendon elasticity and viability. Eventually, the glenohumeral joint experiences a series of degenerative alterations - cuff tear arthropathy. To avert this, a vigilant clinician must utilize and corroborate clinical skill and radiological findings to identify tear progression. Modern radio-diagnostic means of ultrasonography and magnetic resonance imaging provide excellent visualization of structural details and are crucial in determining further course of action for these patients. Physical therapy along with activity modifications, anti-inflammatory and analgesic medications form the pillars of nonoperative treatment. Elderly patients with minimal functional demands can be managed conservatively and reassessed at frequent intervals. Regular monitoring helps in isolating patients who require surgical interventions. Early surgery should be considered in younger, active and symptomatic, healthy patients. In addition to being cost-effective, this helps in providing a functional shoulder with a stable cuff. An easily reproducible technique of maximal strength and

  4. The relationship between tear severity, fatty infiltration, and muscle atrophy in the supraspinatus.

    Science.gov (United States)

    Barry, Jeffrey J; Lansdown, Drew A; Cheung, Sunny; Feeley, Brian T; Ma, C Benjamin

    2013-01-01

    Fatty infiltration and muscle atrophy have been described as interrelated characteristic changes that occur within the muscles of the rotator cuff after cuff tears, and both are independently associated with poor outcomes after surgical repair. We hypothesize that fatty infiltration and muscle atrophy are two distinct processes independently associated with supraspinatus tears. A retrospective review of 377 patients who underwent shoulder magnetic resonance imaging at one institution was performed. Multivariate analysis was performed based on parameters including age, sex, rotator cuff tear severity, fatty infiltration grade, and muscle atrophy. A total of 116 patients (30.8%) had full-thickness tears of the supraspinatus, 153 (40.6%) had partial thickness tears, and 108 (28.7%) had no evidence of tear. With increasing tear severity, the prevalence of substantial fatty infiltration (grade ≥2) increased: 6.5% of patients with no tears vs 41.4% for complete tears (P tear severity: 36.1% of no tears vs 77.6% of complete tears (P muscle atrophy when taking into account sex, age, and tear severity. Fatty infiltration and muscle atrophy are independently associated processes. Fatty infiltration is also related to increasing age, muscle tear severity, and sex, whereas muscle atrophy is related to increasing age but not tear severity. In patients without rotator cuff tears, fatty infiltration and atrophy prevalence increased independently with increasing age. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  5. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    International Nuclear Information System (INIS)

    Tuite, M.J.; Turnbull, J.R.; Orwin, J.F.

    1998-01-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56. Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity for these tears is lower than in recent articles, we found no significant difference between the sensitivity of MR for diagnosing posterior tears versus tears in the anterior half of the supraspinatus tendon. Rim-rent tears can be mistaken for intratendinous signal, and should be carefully looked for in younger patients with shoulder pain. (orig.)

  6. Influence of toroidal rotation on tearing modes

    Science.gov (United States)

    Cai, Huishan; Cao, Jintao; Li, Ding

    2017-10-01

    Tearing modes stability analysis including toroidal rotation is studied. It is found that rotation affects the stability of tearing modes mainly through the interaction with resistive inner region of tearing mode. The coupling of magnetic curvature with centrifugal force and Coriolis force provides a perturbed perpendicular current, and a return parallel current is induced to affect the stability of tearing modes. Toroidal rotation plays a stable role, which depends on the magnitude of Mach number and adiabatic index Γ, and is independent on the direction of toroidal rotation. For Γ >1, the scaling of growth rate is changed for typical Mach number in present tokamaks. For Γ = 1 , the scaling keeps unchanged, and the effect of toroidal rotation is much less significant, compared with that for Γ >1. National Magnetic Confinement Fusion Science Program and National Science Foundation of China under Grants No. 2014GB106004, No. 2013GB111000, No. 11375189, No. 11075161 and No. 11275260, and Youth Innovation Promotion Association CAS.

  7. Role of ultrasound in rotator cuff tears

    International Nuclear Information System (INIS)

    Siddiqi, H.A.; Mirza, T.

    2010-01-01

    The study was designed to evaluate the efficacy of ultrasound in rotator cuff tears and to compare it with MRI. Total number of patients was thirty. All of these were above thirty years of age and were referred by clinicians, with shoulder pain for diagnostic workup. Post operative patients were excluded. Ultrasound and Magnetic Resonance Imaging (MRI) were performed on each patient. Same operator performed ultrasound in all patients. Ultrasound (US) and Magnetic Resonance Imaging (MRI) detected equal number of full thickness tears while two partial thickness tears were missed on US. Hypoechoic defect was the most important primary sign while cortical irregularity and fluid in subacromial and subdeltroid busra were the most important secondary signs on US. US was equally effective to MRI in detection of rotator cuff tears. It should be the primary investigation because of its availability, cost effective and real time evaluation provided significant expertise is developed, as it is highly operator dependent. (author)

  8. Anterior versus posterior, and rim-rent rotator cuff tears: prevalence and MR sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Turnbull, J R; Orwin, J F [Wisconsin Univ., Madison, WI (United States). Dept. of Radiology

    1998-05-01

    Purpose. To determine the relative distribution of the locations of rotator cuff tears, and the sensitivity of anterior versus posterior tears on MR images. Patients and methods. We identified 110 consecutive patients who had a shoulder MR and either a partial-thickness or a small full-thickness rotator cuff tear diagnosed at arthroscopy. From the arthroscopy videotapes, we classified the tears as centered in the anterior or posterior half of the cuff, and as either in the critical zone or adjacent to the bony insertion. The original MR interpretation was compared with the arthroscopic findings. MR sensitivity and patient age were compared between patients with tears in the anterior and posterior halves of the cuff. In addition, in patients with partial tears less than 2 cm in diameter, an age comparison between those with tears in the critical zone and those with articular surface tears adjacent to the bony insertion (rim-rent tear) was performed. Results. The tear was centered in the anterior half of the rotator cuff in 79% of the patients younger than 36 years old, and in 89% of the patients 36 years old and over. The average age of the patients with tears in the anterior half (44 years) was not significantly different from the average age of those with posterior tears (40 years)(P=0.23). The sensitivity of MR for anterior tears was 0.69, and for posterior tears it was 0.56 (P=0.17). The average age of the 9 patients with rim-rent tears was 31 years, while that of the 28 patients with similarly-sized partial tears not involving the insertion was 40 years old (P=0.048). Five of the nine rim-rent tears (0.56) were interpreted correctly on the original MR report; two of the other tears were misinterpreted as intratendinous fluid but were diagnosable in retrospect. Conclusion. Even in patients less than 36 years old, most partial and small full-thickness rotator cuff tears are centered in the anterior half of the supraspinatus. Although our figure for MR sensitivity

  9. Tearing relaxation and the globalization of transport in field-reversed configurations

    International Nuclear Information System (INIS)

    Steinhauer, Loren; Barnes, D. C.

    2009-01-01

    Tearing instability of field-reversed configurations (FRC) is investigated using the method of neighboring equilibria. It is shown that the conducting wall position in experiment lies very close to the location needed for tearing stability. This strongly suggests that vigorous but benign tearing modes, acting globally, are the engine of continual self-organization in FRCs, i.e., tearing relaxation. It also explains the ''profile consistency'' and anomalous loss rate of magnetic flux. In effect, tearing globalizes the effect of edge-driven transport.

  10. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  11. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    International Nuclear Information System (INIS)

    Fotiadou, Anastasia N.; Vlychou, Marianna; Papadopoulos, Periklis; Karataglis, Dimitrios S.; Palladas, Panagiotis; Fezoulidis, Ioannis V.

    2008-01-01

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears

  12. Ultrasonography of symptomatic rotator cuff tears compared with MR imaging and surgery

    Energy Technology Data Exchange (ETDEWEB)

    Fotiadou, Anastasia N. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece); Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: natfot@yahoo.gr; Vlychou, Marianna [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: mvlychou@med.uth.gr; Papadopoulos, Periklis [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: perpap@otenet.gr; Karataglis, Dimitrios S. [University Orthopaedic Clinic, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: dkarataglis@yahoo.gr; Palladas, Panagiotis [Radiology Department, G. Papanikolaou Hospital, Exochi 32100, Thessaloniki (Greece)], E-mail: palladaspan@in.gr; Fezoulidis, Ioannis V. [Radiology Department, University Hospital of Larissa, Mezourlo 41110, Larissa (Greece)], E-mail: oswestanast@yahoo.gr

    2008-10-15

    Purpose: To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears. Materials and methods: Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery. Results: Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively. Conclusions: In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.

  13. On tear film breakup (TBU): dynamics and imaging.

    Science.gov (United States)

    Braun, Richard J; Driscoll, Tobin A; Begley, Carolyn G; King-Smith, P Ewen; Siddique, Javed I

    2018-06-13

    We report the results of some recent experiments to visualize tear film dynamics. We then study a mathematical model for tear film thinning and tear film breakup (TBU), a term from the ocular surface literature. The thinning is driven by an imposed tear film thinning rate which is input from in vivo measurements. Solutes representing osmolarity and fluorescein are included in the model. Osmolarity causes osmosis from the model ocular surface, and the fluorescein is used to compute the intensity corresponding closely to in vivo observations. The imposed thinning can be either one-dimensional or axisymmetric, leading to streaks or spots of TBU, respectively. For a spatially-uniform (flat) film, osmosis would cease thinning and balance mass lost due to evaporation; for these space-dependent evaporation profiles TBU does occur because osmolarity diffuses out of the TBU into the surrounding tear film, in agreement with previous results. The intensity pattern predicted based on the fluorescein concentration is compared with the computed thickness profiles; this comparison is important for interpreting in vivo observations. The non-dimensionalization introduced leads to insight about the relative importance of the competing processes; it leads to a classification of large vs small TBU regions in which different physical effects are dominant. Many regions of TBU may be considered small, revealing that the flow inside the film has an appreciable influence on fluorescence imaging of the tear film.

  14. 49 CFR 173.340 - Tear gas devices.

    Science.gov (United States)

    2010-10-01

    ... SHIPMENTS AND PACKAGINGS Gases; Preparation and Packaging § 173.340 Tear gas devices. (a) Packagings for...) Tear gas devices may not be assembled with, or packed in the same packaging with, mechanically- or manually-operated firing, igniting, bursting, or other functioning elements unless of a type and design...

  15. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    Directory of Open Access Journals (Sweden)

    Xuezhi Lin

    2018-01-01

    Full Text Available Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM but the biocompatibility of these three-dimensional printing (3D-printed plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  16. Progression from calcifying tendinitis to rotator cuff tear

    Energy Technology Data Exchange (ETDEWEB)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke [Department of Orthopaedic Surgery, Medical Center of Kurume University, 155-1 Kokubu-machi, Kurume City, Fukuoka 839-0862 (Japan)

    2003-02-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  17. Progression from calcifying tendinitis to rotator cuff tear

    International Nuclear Information System (INIS)

    Gotoh, Masafumi; Higuchi, Fujio; Suzuki, Ritsu; Yamanaka, Kensuke

    2003-01-01

    This report documents the clinical, radiographic and histologic findings in a 46-year-old man with calcifying tendinitis in his left shoulder which progressed to rotator cuff tear. The patient had a 1-year history of repeated calcifying tendinitis before being referred to our hospital. On the initial visit, radiographs and magnetic resonance imaging (MRI) revealed calcium deposition localized in the supraspinatus tendon without apparent tear. Three months after the first visit, MRI revealed a partial-thickness rotator cuff tear at the site of calcium deposition. Surgical and histologic findings demonstrated that calcium deposition was the cause of cuff rupture. To our knowledge, based on a review of the English literature, this is the first case report in which the progression from calcifying tendinitis to rotator cuff tear has been serially observed. (orig.)

  18. Bilateral Giant Retinal Tear and Sequential Vitrectomy.

    Science.gov (United States)

    Mustapha, Mushawiahti; Roufail Franzco, Edward

    2017-01-01

    To describe the excellent outcome of surgery for bilateral giant retinal tears (GRTs) with better options of endotamponade. This is a case report of a 62-year-old man who presented with bilateral GRTs and associated retinal detachment. The tear in the right eye was supero-temporal and silicone oil was used as an endotamponade. The tear in the left eye was infero-temporal and perfluorocarbon liquid was used as an endotamponade. The outcome at 6 months after surgery was excellent with visual acuities of 6/6 in both eyes. Improved availability of endotamponade agents allows repair of bilateral GRTs to be done at the same time, with good surgical outcomes.

  19. A review of patient and skin characteristics associated with skin tears.

    Science.gov (United States)

    Rayner, R; Carville, K; Leslie, G; Roberts, P

    2015-09-01

    Skin tears are the most common wound among the elderly and have the potential to cause infection, form chronic wounds, reduce quality of life and increase health-care costs. Our aim was to identify studies that reviewed patient and skin characteristics associated with skin tears. A review of skin tear studies reported in the English literature between 1980 and 2013 was undertaken using the following electronic databases: PubMed, Medline, CINAHL, Embase, Scopus, Evidence Based and Medicine Reviews (EBM). Search terms included aged, skin, tears or lacerations, skin tearing, geri tear, epidermal tear and prevalence. There were 343 articles found with using the search terms. After abstract review nine were found to be relevant to the search. The principle findings from these eight published articles and one unpublished study revealed that the most common patient characteristics were a history of skin tears, impaired mobility and impaired cognition. Skin characteristics associated with skin tears included senile purpura, ecchymosis and oedema. This review provides an overview of identified patient and skin characteristics that predispose the elderly to skin tears and exposes the lack of research within this domain. R. Rayner is a recipient of a 2013 Australian Postgraduate Award, Curtin University Postgraduate Scholarship and a Wound Management Cooperative Research Centre (CRC) PhD stipend. The School of Nursing, Midwifery and Paramedicine, Curtin University and the Silver Chain Group, Western Australia are participants in the Wound Management Innovation CRC. No conflict of interest exists among the authors.

  20. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup Análisis del desgaste de la articulación cabeza femoral–copa acetabular mediante simulación experimental con máquina perno-disco

    Directory of Open Access Journals (Sweden)

    Beltrán-Fernandez Juan Alfonso

    2008-07-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.Este trabajo presenta un estudio que permite establecer la vida útil esperada de un sistema prostético de cadera para el caso del fenotipo mexicano. En primera instancia se determinó la distancia total equivalente de deslizamiento y las condiciones de carga entre el componente femoral y la copa acetabular bajo condiciones normales de carga. Posteriormente, se desarrolló una simulación experimental para la realización de un ensayo tribológico en una máquina de desgaste del tipo Perno sobre Disco (Pin on Disk, POD. Este ensayo sometió al conjunto fabricado en acero inoxidable AISI

  1. Hip arthroscopy for Legg-Calvè-Perthes disease: minimum 2-year follow-up.

    Science.gov (United States)

    Freeman, Carl R; Jones, Kay; Byrd, J W Thomas

    2013-04-01

    The purpose of this study is to report the results of arthroscopy for the treatment of adolescents and adults with hip pain cause by sequelae of Legg-Calvè-Perthes disease. All patients undergoing hip arthroscopy were prospectively assessed with the modified Harris Hip Score at 3, 6, 12, 24, 60, 120, and 180 months. We identified a cohort of 22 consecutive patients (23 hips) with Legg-Calvè-Perthes disease who had undergone arthroscopy with at least 2-year follow-up; this cohort represents the substance of this report. There was 100% follow-up at 24 months (range, 24 to 180 months). The median age was 27 years (range, 7 to 58 years) with 14 male and 8 female patients. Findings during arthroscopy included 18 labral tears, 17 hypertrophic or torn ligamentum teres, 9 femoral and 8 acetabular chondral lesions, 5 loose bodies, 3 osteochondral defects, and 2 cam lesions. The mean improvement at 24 months was 28 points (56.7 preoperatively and 82 postoperatively). All patients were improved, although this improvement was negligible in 2 patients who underwent repeat arthroscopy. There were no complications. This series reports the results of arthroscopy for Legg-Calvè-Perthes disease and reflects that it does have a role in the management of painful sequelae. Successful outcomes can often be expected with minimal morbidity. Reduced symptoms and improved quality of life are reasonable expectations, although these data do not suggest that hip arthroscopy alters the natural history of the disease process. Level IV, therapeutic case series. Published by Elsevier Inc.

  2. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  3. Acute Medial Plantar Fascia Tear.

    Science.gov (United States)

    Pascoe, Stephanie C; Mazzola, Timothy J

    2016-06-01

    A 32-year-old man who participated in competitive soccer came to physical therapy via direct access for a chief complaint of plantar foot pain. The clinical examination findings and mechanism of injury raised a concern for a plantar fascia tear, so the patient was referred to the physician and magnetic resonance imaging was obtained. The magnetic resonance image confirmed a high-grade, partial-thickness, proximal plantar fascia tear with localized edema at the location of the medial band. J Orthop Sports Phys Ther 2016;46(6):495. doi:10.2519/jospt.2016.0409.

  4. Pele's tears and spheres

    Science.gov (United States)

    Porritt, L. A.; Quane, S.; Russell, K.

    2011-12-01

    Pele's tears are a well known curiosity commonly associated with low viscosity basaltic explosive eruptions. However, these pyroclasts are rarely studied in detail and there is no full explanation for their formation. These intriguing pyroclasts have smooth glassy surfaces, vesiculated interiors, and fluidal morphologies tending towards droplets and then spheres as they decrease in size to Pele's tears from the 1959 fire-fountaining eruption of Kilauea Iki involving size and density measurements. Using thin section and SEM analysis we also consider their internal and external morphologies, porosity and bubble size distributions, and surface textures. Finally we consider the mechanisms of magma fragmentation, timescales of relaxation, and cooling rates that are responsible for their formation.

  5. Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs

    OpenAIRE

    Kneif, D.; Downing, M.; Ashcroft, G. P.; Gibson, P.; Knight, D.; Ledingham, W.; Hutchison, J.

    2005-01-01

    Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreem...

  6. Magnetic resonance imaging in acute and chronic rotator cuff tears

    International Nuclear Information System (INIS)

    Buirski, G.

    1990-01-01

    Magnetic resonance imaging has been assessed in patients with acute rotator cuff tears and normal radiographs (9 cases) and those with chronic tears and changes of cuff arthropathy (9 cases). All images were obtained using a low field strength system (FONAR 0.3 T). Particular attention was placed on the appearances of the tendon and the cuff muscles themselves. Six complete acute tears were clearly identified, but MRI failed to demonstrate two partial tears. Muscle bulk was preserved in all patients in this group. In contrast, all patients with cuff arthropathy had complete tears of the supraspinatus tendon with marked tendon retraction and associated muscle atrophy: These changes precluded primary surgical repair. MRI should be used to assess muscle atrophy preoperatively in those patients with acute tears. When plain radiographs demonstrate cuff arthropathy, the MRI appearances are predictable and primary repair is unlikely to be successful. Further imaging is therefore not indicated. (orig.)

  7. [Biomechanical significance of the acetabular roof and its reaction to mechanical injury].

    Science.gov (United States)

    Domazet, N; Starović, D; Nedeljković, R

    1999-01-01

    The introduction of morphometry into the quantitative analysis of the bone system and functional adaptation of acetabulum to mechanical damages and injuries enabled a relatively simple and acceptable examination of morphological acetabular changes in patients with damaged hip joints. Measurements of the depth and form of acetabulum can be done by radiological methods, computerized tomography and ultrasound (1-9). The aim of the study was to obtain data on the behaviour of acetabular roof, the so-called "eyebrow", by morphometric analyses during different mechanical injuries. Clinical studies of the effect of different loads on acetabular roof were carried out in 741 patients. Radiographic findings of 400 men and 341 women were analysed. The control group was composed of 148 patients with normal hip joints. Average age of the patients was 54.7 years and that of control subjects 52.0 years. Data processing was done for all examined patients. On the basis of our measurements the average size of female "eyebrow" ranged from 24.8 mm to 31.5 mm with standard deviation of 0.93 and in men from 29.4 mm to 40.3 mm with standard deviation of 1.54. The average size in the whole population was 32.1 mm with standard deviation of 15.61. Statistical analyses revealed high correlation coefficients between the age and "eyebrow" size in men (r = 0.124; p 0.05). The examination of the size of collodiaphysial angle and length of "eyebrow" revealed that "eyebrow" length was in inverse proportion to the size of collodiaphysial angle (r = 0.113; p 0.05) and female (r = 0.005; p > 0.05) patients. The "eyebrow" length was proportionally dependent on the size of the shortened extremity in all examined subjects. This dependence was statistically significant both in female (r = 0.208; p < 0.05) and male (r = 0.193; p < 0.05) patients. The study revealed that fossa acetabuli was forward and downward laterally directed. The size, form and cross-section of acetabulum changed during different

  8. Hemi-bucket-handle tears of the meniscus: appearance on MRI and potential surgical implications

    Energy Technology Data Exchange (ETDEWEB)

    Engstrom, Bjorn I.; Vinson, Emily N.; Helms, Clyde A. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States); Taylor, Dean C.; Garrett, William E. [Duke University Medical Center, Department of Orthopaedics, Box 3810, Durham, NC (United States)

    2012-08-15

    To describe a type of meniscus flap tear resembling a bucket-handle tear, named a ''hemi-bucket-handle'' tear; to compare its imaging features with those of a typical bucket-handle tear; and to discuss the potential therapeutic implications of distinguishing these two types of tears. Five knee MR examinations were encountered with a type of meniscus tear consisting of a flap of tissue from the undersurface of the meniscus displaced toward the intercondylar notch. A retrospective analysis of 100 MR examinations prospectively interpreted as having bucket-handle type tears yielded 10 additional cases with this type of tear. Cases of hemi-bucket-handle tears were reviewed for tear location and orientation, appearance of the superior articular surface of the meniscus, presence and location of displaced meniscal tissue, and presence of several classic signs of bucket-handle tears. A total of 15/15 tears involved the medial meniscus, had tissue displaced toward the notch, and were mainly horizontal in orientation. The superior surface was intact in 11/15 (73.3%). In 1/15 (6.7%) there was an absent-bow-tie sign; 6/15 (40%) had a double-PCL sign; 14/15 (93.3%) had a double-anterior horn sign. We describe a type of undersurface flap tear, named a hemi-bucket-handle tear, which resembles a bucket-handle tear. Surgeons at our institution feel this tear would likely not heal if repaired given its predominantly horizontal orientation, and additionally speculate the tear could be overlooked at arthroscopy. Thus, we feel it is important to distinguish this type of tear from the typical bucket-handle tear. (orig.)

  9. Hemi-bucket-handle tears of the meniscus: appearance on MRI and potential surgical implications

    International Nuclear Information System (INIS)

    Engstrom, Bjorn I.; Vinson, Emily N.; Helms, Clyde A.; Taylor, Dean C.; Garrett, William E.

    2012-01-01

    To describe a type of meniscus flap tear resembling a bucket-handle tear, named a ''hemi-bucket-handle'' tear; to compare its imaging features with those of a typical bucket-handle tear; and to discuss the potential therapeutic implications of distinguishing these two types of tears. Five knee MR examinations were encountered with a type of meniscus tear consisting of a flap of tissue from the undersurface of the meniscus displaced toward the intercondylar notch. A retrospective analysis of 100 MR examinations prospectively interpreted as having bucket-handle type tears yielded 10 additional cases with this type of tear. Cases of hemi-bucket-handle tears were reviewed for tear location and orientation, appearance of the superior articular surface of the meniscus, presence and location of displaced meniscal tissue, and presence of several classic signs of bucket-handle tears. A total of 15/15 tears involved the medial meniscus, had tissue displaced toward the notch, and were mainly horizontal in orientation. The superior surface was intact in 11/15 (73.3%). In 1/15 (6.7%) there was an absent-bow-tie sign; 6/15 (40%) had a double-PCL sign; 14/15 (93.3%) had a double-anterior horn sign. We describe a type of undersurface flap tear, named a hemi-bucket-handle tear, which resembles a bucket-handle tear. Surgeons at our institution feel this tear would likely not heal if repaired given its predominantly horizontal orientation, and additionally speculate the tear could be overlooked at arthroscopy. Thus, we feel it is important to distinguish this type of tear from the typical bucket-handle tear. (orig.)

  10. MRI diagnosis in meniscal tears: a Meta analysis

    International Nuclear Information System (INIS)

    Liu Xiaosheng; Xu Jianrong; Hua Jia; Wang Baisong

    2007-01-01

    Objective: To perform a Meta-analysis to evaluate the overall diagnostic value of magnetic resonance imaging (MRI) in patients with suspected meniscal tears. Methods: All the papers concerning the diagnosis of meniscal tears using MRI in both English and Chinese published from 1998 to 2004 had been searched and reviewed, and the studies with the arthroscopy as the gold standard were adopted as eligible. Statistical analysis was performed employing SAS 8.0. Heterogeneity of the included articles was tested, which was used to select proper effect model to calculate pooled weighted sensitivity, specificity and accuracy. Summary receiver operating characteristic (SROC) analyses were performed for tears of both menisci. Finally, subgroup analysis on magnetic field strength was performed. Results: Totally 11 studies were met the inclusion criteria with a total of 1221 patients. The pooled indexes of diagnostic performance and SROC demonstrated a high discriminatory power for detecting tears of the medial and lateral menisci. The value of TPR * for medial and lateral menisci showed no significant difference (0.90, 0.86, respectively, Z=0.11, P>0.05). Subgroup analysis demonstrated no statistically significant difference on diagnostic performance for various magnetic field strength (P>0.05). Conclusion: MRI is a highly accurate diagnostic tool for detecting tears of the medial and lateral menisci. At present, there is no evidence to ascertain that higher magnetic field strength improves discriminatory power for meniscal tears. (authors)

  11. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    Science.gov (United States)

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (Pcup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Plate Tearing Under Mixed Mode Loading

    DEFF Research Database (Denmark)

    Andersen, Rasmus Grau; Nielsen, Kim Lau; Felter, Christian Lotz

    2016-01-01

    the mesh cannot accurately capture the localization process that precedes ductile failure. To fertilize accurate predictions of such sheet tearing, the energy dissipated during localization must, therefore, be accounted for in the cohesive traction-separation law. The fact is that the local thinning...... that takes place in front of an advancing crack can significantly enhance the crack growth resistanceas the energy going into thinning the sheet typically dominates the total fracture energy.This has been investigated in great details for the case of pure Mode I tearing and both the energy dissipation, peak...... stress, and shape of the cohesive traction-separation law have been laid out. In a similar fashion, the present study resolves the sequence of failure details related to steady-state sheet tearing under mixed mode loading by employing the micro-mechanics based Gurson model. But, the fracture process...

  13. Oxidative Stress Measures of Lipid and DNA Damage in Human Tears.

    Science.gov (United States)

    Haworth, Kristina M; Chandler, Heather L

    2017-05-01

    We evaluate feasibility and repeatability of measures for lipid peroxidation and DNA oxidation in human tears, as well as relationships between outcome variables, and compared our findings to previously reported methods of evaluation for ocular sun exposure. A total of 50 volunteers were seen for 2 visits 14 ± 2 days apart. Tear samples were collected from the inferior tear meniscus using a glass microcapillary tube. Oxidative stress biomarkers were quantified using enzyme-linked immunosorbent assay (ELISA): lipid peroxidation by measurement of hexanoyl-lysine (HEL) expression; DNA oxidation by measurement of 8-oxo-2'-deoxyguinosone (8OHdG) expression. Descriptive statistics were generated. Repeatability estimates were made using Bland-Altman plots with mean differences and 95% limits of agreement were calculated. Linear regression was conducted to evaluate relationships between measures. Mean (±SD) values for tear HEL and 8OHdG expression were 17368.02 (±9878.42) nmol/L and 66.13 (±19.99) ng/mL, respectively. Repeatability was found to be acceptable for both HEL and 8OHdG expression. Univariate linear regression supported tear 8OHdG expression and spring season of collection to be predictors of higher tear HEL expression; tear HEL expression was confirmed as a predictor of higher tear 8OHdG expression. We demonstrate feasibility and repeatability of estimating previously unreported tear 8OHdG expression. Seasonal temperature variation and other factors may influence tear lipid peroxidation. Support is demonstrated to suggest lipid damage and DNA damage occur concurrently on the human ocular surface.

  14. MRI diagnosis of ACL bundle tears: value of oblique axial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Alex W.H.; Griffith, James F.; Hung, Esther H.Y. [Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China); Law, Kan Yip; Yung, Patrick S.H. [Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince of Wales Hospital, Shatin, NT, Hong Kong SAR (China)

    2013-02-15

    To investigate the diagnostic accuracy of oblique axial intermediate weighting MR imaging in detecting partial thickness anterior cruciate ligament (ACL) bundle tears. The study protocol was approved by the institutional ethics committee. Sixty-one subjects (43 male, 18 female; mean age 27.4 years; range 9 to 57 years) with clinically suspected ACL tear or meniscal tear between September 2009 and January 2011 were studied with MRI and arthroscopy. Detection of partial tear for the ACL as a whole and for each ACL bundle by protocol A (standard orthogonal sequences) and protocol B (standard orthogonal sequences plus oblique axial intermediate weighted imaging) was compared in a blinded fashion. Performance characteristics for protocol A and protocol B were compared using sensitivity, specificity, accuracy and ROC curves. A two-tailed p value of <0.05 indicated statistical significance. Fifteen (24.6%) normal, 15 (24.6%) partial and 31 complete tears were diagnosed by arthroscopy. Sensitivity, specificity and accuracy of protocol A for the diagnosis of partial tear of the ACL was 33%, 87% and 74%, while for protocol B the values were 87%, 87% and 87% respectively. The area under the curve (AUC) for the diagnosis of partial ACL tear and individual bundle tear was higher for protocol B, although this difference did not reach statistical significance (p > 0.05). The addition of oblique axial imaging to standard MR imaging improves diagnostic accuracy for detecting partial tears of the ACL as well as individual bundle tears of the ACL. (orig.)

  15. Proteases, proteolysis and inflammatory molecules in the tears of people with keratoconus.

    Science.gov (United States)

    Balasubramanian, Sivaraman Arumugam; Mohan, Sujatha; Pye, David Cecil; Willcox, Mark Duncan Perry

    2012-06-01

    To investigate the expression of proteases, proteolytic activity and cytokines in the tear film of people with keratoconus. Basal tears from people with keratoconus, from individuals who had undergone corneal collagen cross-linking for the treatment of keratoconus, and from normal controls were collected using a capillary tube. Corneal curvature of each subject was mapped. The total protein in tears was estimated. Levels and activity of proteases in the tears were analysed using specific antibody arrays and activity assays. The total tear protein level was significantly reduced in keratoconus (4.1 ± 0.9 mg/ml) compared with normals (6.7 ± 1.4 mg/ml) (p tear expression of matrix metalloproteinases (MMP) -1, -3, -7, -13, interleukins (IL) -4, -5, -6, -8 and tumour necrosis factor (TNF) -α, -β were evident in keratoconus. Tear IL-6 was the only cytokine significantly (p tears of keratoconus subjects compared with the collagen cross-linked group. No significant difference in tear proteases were observed between the normal and the cross-linked groups, although the expression of TNF-α was significantly (p tears from keratoconus compared with normal subjects. The activity of tear gelatinases (69.6 ± 22.2 FIU) and collagenases (5.7 ± 3.3 FIU) in the collagen cross-linked group was not significantly different compared with either keratoconus or normals. Tears of people with keratoconus had 1.9 times higher levels of proteolytic activity and over expression of several MMPs and cytokines compared with tears from controls. Further investigations are required to study the possible implications of these changes and whether they can be used to monitor disease progression or determine the success of corneal collagen cross-linking. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  16. Complex descemet′s membrane tears and detachment during phacoemulsification

    Directory of Open Access Journals (Sweden)

    Faik Orucoglu

    2015-01-01

    Full Text Available Purpose: To report a case of complex Descemet′s membrane detachment (DMD and tears during phacoemulsification cataract surgery. Case Report: A 64-year-old woman underwent phacoemulsification surgery in her right eye and developed tears and partial loss of Descemet′s membrane (DM while the aspiration port was inserted through the main incision. Massive corneal edema obscured the view and the anterior chamber was barely visible the following day. Scheimpflug imaging was used to complement slit lamp examination in the postoperative period. Frequent topical corticosteroid drops were initiated. After 5 days of treatment, multiple tears and detachment of DM were visible and the anterior chamber was filled with air. After 5 weeks, the cornea regained much of its clarity despite large DM tears and focal loss of DM. Conclusion: Despite partial loss of DM, the corneal edema mostly disappeared after 5 weeks of air bubble injection. Scheimpflug imaging was beneficial in the diagnosis and monitoring of DM tears and detachments.

  17. Neoclassical tearing modes in a tokamak

    International Nuclear Information System (INIS)

    Hahm, T.S.

    1988-08-01

    Linear tearing instability is studied in the banana collisionality regime in tokamak geometry. Neoclassical effects produce significant modifications of Ohm's law and the vorticity equation so that the growth rate of tearing modes driven by Δ' is dramatically reduced compared to the usual resistive MHD value. Consequences of this result, regarding the presence of pressure-gradient-driven neoclassical resistive interchange instabilities and the evolution of magnetic islands in the Rutherford regime, are discussed. 10 refs

  18. Introduction to the linear theory of tearing instabilities

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1978-02-01

    The reasons why tearing instabilities might bear importantly on tokamak performance are considered. The mechanism of tearing is described and the method by which this mechanism is analyzed is outlined. A survey is given of typical growth rate predictions

  19. Posterior vitreous detachment - prevalence of and risk factors for retinal tears

    Directory of Open Access Journals (Sweden)

    Bond-Taylor M

    2017-09-01

    Full Text Available Martin Bond-Taylor,1 Gunnar Jakobsson,1,2 Madeleine Zetterberg1,2 1Department of Ophthalmology, Sahlgrenska University Hospital, Mölndal, 2Department of Clinical Neuroscience/Ophthalmology, Institute of Neuroscience and Physiology, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden Purpose: The present study aimed to describe clinical characteristics of patients with posterior vitreous detachment (PVD, to determine the prevalence of retinal tears in PVD patients, and to find predictors for retinal tears in this patient group. Methods: Retrospective analysis of medical records on patients diagnosed with PVD, retinal tears, or vitreous hemorrhage at the Department of Ophthalmology at Sahlgrenska University Hospital, a tertiary eye center. Results: Between February and July 2009, 365 patients consulted the Department of Ophthalmology for PVD-related symptoms. The incidence of retinal tears was 14.5% (n=53 and that of vitreous and/or retinal hemorrhage was 22.7% (n=83. For analysis of possible predictors for complications to PVD, patients diagnosed with retinal tears or vitreous hemorrhage between May and July 2009 were also included in the study, resulting in a total of 426 patients. Predictors of a retinal tear were symptoms of visual impairment (P=0.024, the presence of vitreous or retinal hemorrhage at examination (P<0.001, and a duration of symptoms for <24 hours (P=0.004. Symptoms of flashes did not constitute an extra risk of retinal tears (P=0.135. Subsequent retinal pathology (follow-up time 4.5 years, including vitreous detachment/hemorrhage or retinal tears/detachment, occurred more often in patients presenting with a retinal tear. For patients with a retinal tear, the relative risk of having a retinal detachment in the same eye during the follow-up time was 17.7 when compared to patients without a retinal tear (risk ratio 17.7, 95% confidence interval 2.2–145. Conclusion: Patients seeking care on the first day have a

  20. Supraspinatus tendon tears: comparison of 3D US and MR arthrography with surgical correlation

    International Nuclear Information System (INIS)

    Kang, Chang Ho; Kim, Sam Soo; Kim, Jung Hyuk; Chung, Kyoo Byung; Kim, Yun Hwan; Oh, Yu-Whan; Jeong, Woong-Kyo; Kim, Baek Hyun

    2009-01-01

    The objective of the study was to compare the diagnostic reliability of 3D US with MR arthrography in diagnosing supraspinatus tendon tears, with arthroscopic findings used as the standard. In a prospective study 50 patients who later underwent arthroscopic surgery of the rotator cuff were examined pre-operatively by 3D US with MR arthrography. The presence or absence of a full- or partial-thickness supraspinatus tendon tear and the tear size as demonstrated by each imaging and arthroscopy was recorded. The tear size was divided into three grades: small ( 3 cm). The arthroscopic diagnosis was a full-thickness tear in 40 patients, partial-thickness tears in 5, and intact supraspinatus tendon in 5. 3D US correctly diagnosed 35 out of 40 full-thickness tears and MR arthrography 39 out of 40 full-thickness tears. Regarding partial-thickness tears, 3D US underestimated 2 cases as no tear and overestimated 1 case as a full-thickness tear. MR arthrography underestimated 1 case as a partial-thickness tear and overestimated 2 cases as full-thickness and partial-thickness tears respectively. 3D US and MR arthrography yield a sensitivity for full-thickness tears of 87.5% and 97.5% with specificity of 90.0% and 90.0%. Based on the grading system, 3D US measurements correctly predicted the tear size of 23 (65.7%) of the 35 full-thickness tears and MR arthrography 30 (75.0%) of the 39 full-thickness tears. Three-dimensional ultrasound seems to be a promising imaging modality comparable to MR arthrography for the assessment of the supraspinatus tendon tears. (orig.)