WorldWideScience

Sample records for acetabular cup system

  1. Acetabular Cup Revision.

    Science.gov (United States)

    Kim, Young-Ho

    2017-09-01

    The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.

  2. The Evolution of the Cup-Cage Technique for Major Acetabular Defects: Full and Half Cup-Cage Reconstruction.

    Science.gov (United States)

    Sculco, Peter K; Ledford, Cameron K; Hanssen, Arlen D; Abdel, Matthew P; Lewallen, David G

    2017-07-05

    Complex acetabular reconstruction for major bone loss can require advanced methods such as the use of a cup-cage construct. The purpose of this study was to review outcomes after the initial development of the cup-cage technique and the subsequent evolution to the use of a half cup-cage construct. We performed a retrospective, single-center review of 57 patients treated with cup-cage reconstruction for major acetabular bone loss. All patients had major acetabular defects graded as Paprosky Type 2B through 3B, with 34 (60%) having an associated pelvic discontinuity. Thirty patients received a full cup-cage construct and 27, a half cup-cage construct. The mean follow-up was 5 years. Both the full and half cup-cage cohorts demonstrated significantly improved Harris hip score (HHS) values, from 36 to 72 at a minimum of 2 years of follow-up (p cup-cage constructs and 6 (22%) of the half cup-cage constructs. One patient with a full cup-cage construct underwent re-revision of the acetabular component for progressive migration and aseptic loosening. Short-term survivorship free from re-revision for any cause or reoperation was 89% (83% and 96% for full and half cup-cage cohorts, respectively). Both full and half cup-cage constructs demonstrated successful clinical outcomes and survivorship in the treatment of major acetabular defects and pelvic discontinuity. Each method is utilized on the basis of individual intraoperative findings, including the extent and pattern of bone loss, the quality and location of host bone remaining after preparation, and the presence of pelvic discontinuity. Longer-term follow-up is required to understand the durability of these constructs in treating major acetabular defects and pelvic discontinuity. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  3. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    Science.gov (United States)

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. A new technique for radiographic measurement of acetabular cup orientation.

    Science.gov (United States)

    Derbyshire, Brian; Diggle, Peter J; Ingham, Christopher J; Macnair, Rory; Wimhurst, James; Jones, Henry Wynn

    2014-02-01

    Accurate radiographic measurement of acetabular cup orientation is required in order to assess susceptibility to impingement, dislocation, and edge loading wear. In this study, the accuracy and precision of a new radiographic cup orientation measurement system were assessed and compared to those of two commercially available systems. Two types of resurfacing hip prostheses and an uncemented prosthesis were assessed. Radiographic images of each prosthesis were created with the cup set at different, known angles of version and inclination in a measurement jig. The new system was the most accurate and precise and could repeatedly measure version and inclination to within a fraction of a degree. In addition it has a facility to distinguish cup retroversion from anteversion on anteroposterior radiographs. © 2013.

  5. Acetabular cup position and risk of dislocation in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Seagrave, Kurt G; Troelsen, Anders; Malchau, Henrik

    2017-01-01

    Background and purpose - Hip dislocation is one of the most common complications following total hip arthroplasty (THA). Several factors that affect dislocation have been identified, including acetabular cup positioning. Optimal values for cup inclination and anteversion are debatable. We performed...... a systematic review to describe the different methods for measuring cup placement, target zones for cup positioning, and the association between cup positioning and dislocation following primary THA. Methods - A systematic search of literature in the PubMed database was performed (January and February 2016......) to identify articles that compared acetabular cup positioning and the risk of dislocation. Surgical approach and methods for measurement of cup angles were also considered. Results - 28 articles were determined to be relevant to our research question. Some articles demonstrated that cup positioning influenced...

  6. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup

    Directory of Open Access Journals (Sweden)

    Guillermo Urriolagoitia-Calderón

    2008-01-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.

  7. Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

    Science.gov (United States)

    Vincent, John; Alshaygy, Ibrahim; Muir, Jeffrey M; Kuzyk, Paul

    2018-01-01

    While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case

  8. Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

    Science.gov (United States)

    Krishnamoorthy, Vignesh P; Perumal, Rajamani; Daniel, Alfred J; Poonnoose, Pradeep M

    2015-12-01

    Templating of the acetabular cup size in Total Hip Replacement (THR) is normally done using conventional radiographs. As these are being replaced by digital radiographs, it has become essential to create a technique of templating using digital films. We describe a technique that involves templating the digital films using the universally available acetate templates for THR without the use of special software. Preoperative digital radiographs of the pelvis were taken with a 30 mm diameter spherical metal ball strapped over the greater trochanter. Using standard acetate templates provided by the implant company on magnified digital radiographs, the size of the metal ball (X mm) and acetabular cup (Y mm) were determined. The size of the acetabular cup to be implanted was estimated using the formula 30*Y/X. The estimated size was compared with the actual size of the cup used at surgery. Using this technique, it was possible to accurately predict the acetabular cup size in 28/40 (70%) of the hips. When the accuracy to within one size was considered, templating was correct in 90% (36/40). When assessed by two independent observers, there was good intra-observer and inter-observer reliability with intra-class correlation coefficient values greater than 0.8. It was possible to accurately and reliably predict the size of the acetabular cup, using acetate templates on digital films, without any digital templates.

  9. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    Science.gov (United States)

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Human bone ingrowth into a porous tantalum acetabular cup

    Directory of Open Access Journals (Sweden)

    Gregory N. Haidemenopoulos

    2017-11-01

    Full Text Available Porous Tantalum is increasingly used as a structural scaffold in orthopaedic applications. Information on the mechanisms of human bone ingrowth into trabecular metal implants is rather limited. In this work we have studied, qualitatively, human bone ingrowth into a retrieved porous tantalum monoblock acetabular cup using optical microscopy, scanning electron microscopy and energy dispersive X-ray analysis. According to the results and taking into account the short operational life (4 years of the implant, bone ingrowth on the acetabular cup took place in the first two-rows of porous tantalum cells to an estimated depth of 1.5 to 2 mm. The bone material, grown inside the first raw of cells, had almost identical composition with the attached bone on the cup surface, as verified by the same Ca:P ratio. Bone ingrowth has been a gradual process starting with Ca deposition on the tantalum struts, followed by bone formation into the tantalum cells, with gradual densification of the bone tissue into hydroxyapatite. A critical step in this process has been the attachment of bone material to the tantalum struts following the topology of the porous tantalum scaffold. These results provide insight to the human bone ingrowth process into porous tantalum implants.

  11. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.

    Science.gov (United States)

    Teeter, Matthew G; Goyal, Prateek; Yuan, Xunhua; Howard, James L; Lanting, Brent A

    2018-01-01

    The purpose of this study is to measure acetabular cup position and wear of the highly crosslinked polyethylene liner in the supine and standing position for patients at a minimum of 10 years after the operation. A total of 38 patients were recruited at a mean of 12.5 years after the operation. All patients received a single acetabular cup design with a highly crosslinked liner and a 28-mm cobalt-chromium femoral head. Patients underwent supine and standing radiostereometric examinations in which the X-ray sources and detectors were positioned to obtain an anterior-posterior and cross-table lateral radiograph. Acetabular cup position and the three-dimensional wear rate were measured from the radiographs, and outcome scores were recorded for each patient. Anteversion significantly increased (P cup orientation and wear rate in either position. Highly crosslinked polyethylene is a forgiving bearing material. Although adherence to the traditional acetabular position target zone is recommended, ensuring hip stability and consideration of the patient's functional position are also important objectives to consider for the acetabular position. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Intra- and inter-observer agreement and reliability of bone mineral density measurements around acetabular cup

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    2017-01-01

    in measuring bone density (BMD) in complex anatomic structures which might be overcome using dual-energy computed tomography (DECT).PurposeTo test inter- and intra-observer agreement and reliability of in-house segmentation software measuring BMD adjacent to acetabular cup and to compare measurements performed...... with single-energy CT (SECT) and DECT in cemented and cementless cups.Material and Methods: Twenty-four acetabular cups inserted in porcine hip specimens were scanned with SECT and DECT. Bone density was measured in a three-dimensional volume adjacent to the cup. Double measurements were performed.......Results: BMD derived from SECT was approximately four times higher than that of DECT. In both scan modes, intraclass correlation coefficient (ICC) was >0.90 with no differences between repeated measurements, except for uncemented cups where a statistically significant difference of 11 mg/cm3 was found...

  13. Initial stability of a highly porous titanium cup in an acetabular bone defect model.

    Science.gov (United States)

    Yoshimoto, Kensei; Nakashima, Yasuharu; Wakiyama, Miyo; Hara, Daisuke; Nakamura, Akihiro; Iwamoto, Mikio

    2018-04-12

    The purpose of this study was to quantify the initial stability of a highly porous titanium cup using an acetabular bone defect model. The maximum torque of a highly porous titanium cup, with a pore size of 640 μm and porosity of 60%, was measured using rotational and lever-out torque testing and compared to that of a titanium-sprayed cup. The bone models were prepared using a polyurethane foam block and had three levels of bone coverage: 100, 70, and 50%. The highly porous titanium cup demonstrated significantly higher maximum torque than the titanium-sprayed cups in the three levels of bone defects. On rotational torque testing, it was found to be 1.5, 1.3, and 1.3 times stronger than the titanium-sprayed cups with 100, 70 and 50% bone coverage, respectively. Furthermore, it was found to be 2.2, 2.3, and 1.5 times stronger on lever-out testing than the titanium-sprayed cup. No breakage in the porous layers was noted during the testing. This study provides additional evidence of the initial stability of highly porous titanium cup, even in the presence of acetabular bone defects. Copyright © 2018. Published by Elsevier B.V.

  14. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.

    Science.gov (United States)

    Korduba, Laryssa A; Essner, Aaron; Pivec, Robert; Lancin, Perry; Mont, Michael A; Wang, Aiguo; Delanois, Ronald E

    2014-10-01

    The effect of acetabular component positioning on the wear rates of metal-on-polyethylene articulations has not been extensively studied. Placement of acetabular cups at abduction angles of more than 40° has been noted as a possible reason for early failure caused by increased wear. We conducted a study to evaluate the effects of different acetabular cup abduction angles on polyethylene wear rate, wear area, contact pressure, and contact area. Our in vitro study used a hip joint simulator and finite element analysis to assess the effects of cup orientation at 4 angles (0°, 40°, 50°, 70°) on wear and contact properties. Polyethylene bearings with 28-mm cobalt-chrome femoral heads were cycled in an environment mimicking in vivo joint fluid to determine the volumetric wear rate after 10 million cycles. Contact pressure and contact area for each cup abduction angle were assessed using finite element analysis. Results were correlated with cup abduction angles to determine if there were any differences among the 4 groups. The inverse relationship between volumetric wear rate and acetabular cup inclination angle demonstrated less wear with steeper cup angles. The largest abduction angle (70°) had the lowest contact area, largest contact pressure, and smallest head coverage. Conversely, the smallest abduction angle (0°) had the most wear and most head coverage. Polyethylene wear after total hip arthroplasty is a major cause of osteolysis and aseptic loosening, which may lead to premature implant failure. Several studies have found that high wear rates for cups oriented at steep angles contributed to their failure. Our data demonstrated that larger cup abduction angles were associated with lower, not higher, wear. However, this potentially "protective" effect is likely counteracted by other complications of steep cup angles, including impingement, instability, and edge loading. These factors may be more relevant in explaining why implants fail at a higher rate if

  15. Short-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery.

    Science.gov (United States)

    Mohaddes, Maziar; Rolfson, Ola; Kärrholm, Johan

    2015-02-01

    The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were performed using a TM cup. We compared the risk of reoperation and re-revision for TM cups and the 2 other most frequently used cup designs in acetabular revisions reported to the SHAR. The hypothesis was that the performance of TM cups is as good as that of established designs in the short term. The study population consisted of 2,384 patients who underwent 2,460 revisions during the period 2006 through 2012. The most commonly used cup designs were the press-fit porous-coated cup (n = 870), the trabecular metal cup (n = 805), and the cemented all-polyethylene cup (n = 785). 54% of the patients were female, and the median age at index revision was 72 (19-95) years. Reoperation was defined as a second surgical intervention, and re-revision-meaning exchange or removal of the cup-was used as endpoint. The mean follow-up time was 3.3 (0-7) years. There were 215 reoperations, 132 of which were re-revisions. The unadjusted and adjusted risk of reoperation or re-revision was not significantly different for the TM cup and the other 2 cup designs. Our data support continued use of TM cups in acetabular revisions. Further follow-up is necessary to determine whether trabecular metal cups can reduce the re-revision rate in the long term, compared to the less costly porous press-fit and cemented designs.

  16. Profundization of acetabular cup uncemented in total substitution of hip in-patient with acetabular dysplasia - Experience university hospital - Clinica San Rafael

    International Nuclear Information System (INIS)

    Dimian Mayorga, Omar David; Sandoval Daza, Alejandro; Vargas Turriago, Marcela; Perez Torres, Javier

    2005-01-01

    14 patients with acetabular dysplasia were treated at Hospital Universitario Clinica San Rafael with total hip arthroplasty with uncemented cup internization. According to Crowe classification, one was type 1, eight were type 2 and five were type 3. The average follow up was twenty-four months. The Harris hip score was used for the clinical evaluation with a pre operative average of 35 points and 37 points post operative. The average cup internization was four millimeters, with an average cup protrutio of 47% and an average of cup coverage of 81%. The average internization of the femoral head's center was 26mm. screws for cup fixation were used in 3 patients. We did not have complications nor implant revision at the time of follow up

  17. Morphological experimental study of bone stress at the interface acetabular bone/prosthetic cup in the bipolar hip prosthesis.

    Science.gov (United States)

    Anuşca, D; Pleşea, I E; Iliescu, N; Tomescu, P; Poenaru, F; Dascălu, V; Pop, O T

    2006-01-01

    By calculating the tension and distortion of the elements composing the bipolar prosthesis under extreme conditions encountered in real life using a special post-processing program, we established the variation curves of the contact pressure at the hip bone-cup, armor-cup and cup-femoral head interface. By comparing the data obtained from all the examined cases, important conclusions were drawn regarding the influence of tension and pressure distribution on the structural integrity and biomechanics of the prosthesis, as well as the acetabular wear and tear, in order to assess its reliability. The experimentally determined tension and distortion status at the acetabular bone-metal armour interface, lead to the wear and tear phenomenon, which can be explained by three mechanisms and theories incompletely reflecting the overall process. The histopathologic study of the acetabular bone tissue using FEM (finite elements method) on surgically removed specimens will probably lead to the identification of a series of factors that could reduce the rate of the wear and tear process.

  18. Ultrasound in Total Hip Replacement: Value of Anterior Acetabular Cup Visibility and Contact With the Iliopsoas Tendon.

    Science.gov (United States)

    Guillin, Raphaël; Bertaud, Valérie; Garetier, Marc; Fantino, Olivier; Polard, Jean-Louis; Lambotte, Jean-Christophe

    2018-06-01

    To assess visibility of the acetabular cup in total hip replacement and to determine the value of direct and indirect signs of iliopsoas impingement syndrome with ultrasound. Ultrasound examinations were performed by a single operator in 17 patients with iliopsoas impingement syndrome and 48 control patients. Cup visibility, contact between the cup and psoas tendon, and the presence of indirect signs of iliopsoas impingement syndrome were investigated in all patients. When the acetabular cup was visible, its size and position in relation to the psoas tendon were recorded. Anterior cup visibility (P = .03), contact with the psoas tendon (P cup shift of 3 mm or greater yielded respective sensitivities of 82% and 59% and specificities of 81% and 100%. When iliopsoas impingement syndrome is clinically suspected, the presence of iliopsoas bursitis or a posteroanterior cup shift of greater than 3 mm under the psoas tendon serve to confirm the diagnosis. In the absence of these conditions, a therapeutic test may be necessary because of the incomplete, albeit high, specificity of other signs. © 2017 by the American Institute of Ultrasound in Medicine.

  19. Improving the accuracy of acetabular cup implantation using a bulls-eye spirit level.

    Science.gov (United States)

    Macdonald, Duncan; Gupta, Sanjay; Ohly, Nicholas E; Patil, Sanjeev; Meek, R; Mohammed, Aslam

    2011-01-01

    Acetabular introducers have a built-in inclination of 45 degrees to the handle shaft. With patients in the lateral position, surgeons aim to align the introducer shaft vertical to the floor to implant the acetabulum at 45 degrees. We aimed to determine if a bulls-eye spirit level attached to an introducer improved the accuracy of implantation. A small circular bulls-eye spirit level was attached to the handle of an acetabular introducer. A saw bone hemipelvis was fixed to a horizontal, flat surface. A cement substitute was placed in the acetabulum and subjects were asked to implant a polyethylene cup, aiming to obtain an angle of inclination of 45 degrees. Two attempts were made with the spirit level masked and two with it unmasked. The distance of the air bubble from the spirit level's center was recorded by a single assessor. The angle of inclination of the acetabular component was then calculated. Subjects included both orthopedic consultants and trainees. Twenty-five subjects completed the study. Accuracy of acetabular implantation when using the unmasked spirit level improved significantly in all grades of surgeon. With the spirit level masked, 12 out of 50 attempts were accurate at 45 degrees inclination; 11 out of 50 attempts were "open," with greater than 45 degrees of inclination, and 27 were "closed," with less than 45 degrees. With the spirit level visible, all subjects achieved an inclination angle of exactly 45 degrees. A simple device attached to the handle of an acetabular introducer can significantly improve the accuracy of implantation of a cemented cup into a saw bone pelvis in the lateral position.

  20. A new method for the measurement of anteversion of the acetabular cup after total hip arthroplasty.

    Science.gov (United States)

    Aydogan, Mehmet; Burç, Halil; Saka, Gursel

    2014-08-01

    Many methods of determining the anteversion of the acetabular cup have been described in the literature. The advantages and disadvantages of each of these methods are discussed in this paper. We present a new method of measuring the acetabular anteversion at the anteroposterior hip. The formula designed by the authors was anteversion angle (α) = arc sin |PK|/√ |AK| × |BK|. The formula was tested using the AutoCAD software, and an experimental study was conducted to evaluate the accuracy. Three groups were created, and 16 X-ray images were taken and coded. Ten orthopaedic surgeons measured the acetabular anteversion from these X-rays using our formula. The results in Group 1 were closer to the actual value; in contrast, the results in Group 2 differed from the actual values. The results in Group 3 were as close to the actual anteversion values as were those in Group 1. Developments in technology often bring an increase in complications. Despite newly developed surgical methods and technology, the position of the acetabular cup is still used to determine the results of a total hip arthroplasty. Our method is simple, cost-effective and achieves almost 100 % accuracy.

  1. Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty.

    Science.gov (United States)

    Ozden, Vahit Emre; Dikmen, Goksel; Beksac, Burak; Tozun, Ismail Remzi

    2018-05-01

    Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage. Copyright © 2018 The Japanese

  2. Influence of soft tissue in the assessment of the primary fixation of acetabular cup implants using impact analyses.

    Science.gov (United States)

    Bosc, Romain; Tijou, Antoine; Rosi, Giuseppe; Nguyen, Vu-Hieu; Meningaud, Jean-Paul; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Haiat, Guillaume

    2018-06-01

    The acetabular cup (AC) implant primary stability is an important determinant for the success of cementless hip surgery but it remains difficult to assess the AC implant fixation in the clinic. A method based on the analysis of the impact produced by an instrumented hammer on the ancillary has been developed by our group (Michel et al., 2016a). However, the soft tissue thickness present around the acetabulum may affect the impact response, which may hamper the robustness of the method. The aim of this study is to evaluate the influence of the soft tissue thickness (STT) on the acetabular cup implant primary fixation evaluation using impact analyses. To do so, different AC implants were inserted in five bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the AC implant was impacted 25 times with 10 and 30 mm of soft tissues positioned underneath the sample. The averaged indicator I m was determined based on the amplitude of the signal for each configuration and each STT and the pull-out force was measured. The results show that the resonance frequency of the system increases when the value of the soft tissue thickness decreases. Moreover, an ANOVA analysis shows that there was no significant effect of the value of soft tissue thickness on the values of the indicator I m (F = 2.33; p-value = 0.13). This study shows that soft tissue thickness does not appear to alter the prediction of the acetabular cup implant primary fixation obtained using the impact analysis approach, opening the path towards future clinical trials. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    Science.gov (United States)

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  4. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai, MD

    2017-09-01

    Full Text Available Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  5. Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

    Science.gov (United States)

    Derbyshire, Brian

    2018-03-01

    Radiographic measurement of two-dimensional acetabular cup wear is usually carried out on a series of follow-up radiographs of the patient's pelvis. Since the orientation of the pelvis might not be consistent at every X-ray examination, the resulting change in view of the wear plane introduces error into the linear wear measurement. This effect is amplified on some designs of cup in which the centre of the socket is several millimetres below the centre of the cup or circular wire marker. This study describes the formulation of a mathematical method to correct radiographic wear measurements for changes in pelvis orientation. A mathematical simulation of changes in cup orientation and wear vectors caused by pelvic tilt was used to confirm that the formulae corrected the wear exactly if the radiographic plane of the reference radiograph was parallel to the true plane of wear. An error analysis showed that even when the true wear plane was not parallel to the reference radiographic plane, the formulae could still provide a useful correction. A published correction formula was found to be ineffective.

  6. High proximal migration in cemented acetabular revisions operated with bone impaction grafting; 47 revision cups followed with RSA for 17 years.

    Science.gov (United States)

    Mohaddes, Maziar; Herberts, Peter; Malchau, Henrik; Johanson, Per-Erik; Kärrholm, Johan

    2017-05-12

    Bone impaction grafting is a biologically and mechanically appealing option in acetabular revision surgery, allowing restitution of the bone stock and restoration of the biomechanics. We analysed differences in proximal migration of the revision acetabular components when bone impaction grafting is used together with a cemented or an uncemented cup. 43 patients (47 hips), revised due to acetabular loosening and judged to have less than 50% host bone-implant contact were included. The hips were randomised to either an uncemented (n = 20) or a cemented (n = 27) revision cup. Radiostereometry and radiography was performed postoperatively, at 3 and 6 months, 1, 2, 3, 5, 7, 10 and 13 and 17 years postoperatively. Clinical follow-up was performed at 1, 2 and 5 years postoperatively and thereafter at the same interval as in the radiographic follow-up. There were no differences in the base line demographic data between the 2 groups. At the last follow-up (17 years) 14 hips (10 cemented, 4 uncemented) had been re-revised due to loosening. 3 additional cups (1 uncemented and 2 cemented) were radiographically loose. There was a higher early proximal migration in the cemented cups. Cups operated on with cement showed a higher early migration measured with RSA and also a higher number of late revisions. The reason for this is not known, but factors such as inclusion of cases with severe bone defects, use of smaller bone chips and issues related to the impaction technique might have had various degrees of influence.

  7. Radiology in Gerard uncemented double cup arthroplasty

    International Nuclear Information System (INIS)

    Willems, W.J.; Rozing, P.M.; Obermann, W.R.

    1988-01-01

    A radiological follow-up was performed on 109 Gerard (uncemented) double cup arthroplasties, with special emphasis on shift of the femoral cup and protrusion of the acetabular cup, for which a new formula was introduced. Varus shift or axial collapse of the femoral cup played a major role in the failure of these cups. Fluoroscopic examination with video-tape recording seemed to be most helpful in determining abnormalities in this kind of arthroplasty. This examination revealed one normal and two abnormal types of movement, either between both cups or between acetabular cup and acetabular cavity. Those hips with normal movement showed a significantly better clinical score. 16 refs.; 6 figs

  8. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty?

    Science.gov (United States)

    Erivan, R; Aubret, S; Villatte, G; Mulliez, A; Descamps, S; Boisgard, S

    2017-09-01

    When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (Pcup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    Science.gov (United States)

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Does surface roughness influence the primary stability of acetabular cups? A numerical and experimental biomechanical evaluation.

    Science.gov (United States)

    Le Cann, Sophie; Galland, Alexandre; Rosa, Benoît; Le Corroller, Thomas; Pithioux, Martine; Argenson, Jean-Noël; Chabrand, Patrick; Parratte, Sébastien

    2014-09-01

    Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    Science.gov (United States)

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  12. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review.

    Science.gov (United States)

    Snijders, Thom E; Willemsen, Koen; van Gaalen, Steven M; Castelein, Rene M; Weinans, Harrie; de Gast, Arthur

    2018-05-01

    Dislocation is one of the main reasons for revision of total hip arthroplasty but dislocation rates have not changed in the past decades, compromising patients' well-being. Acetabular cup orientation plays a key role in implant stability and has been widely studied. This article investigates whether there is a consensus on optimal cup orientation, which is necessary when using a navigation system. A systematic search of the literature in the PubMed, Embase and Cochrane databases was performed (March 2017) to identify articles that investigated the direct relationship between cup orientation and dislocation, including a thorough evaluation of postoperative cup orientation assessment methods. Twenty eight relevant articles evaluating a direct relation between dislocation and cup orientation could not come to a consensus. The key reason is a lack of uniformity in the assessment of cup orientation. Cup orientation is assessed with different imaging modalities, different methodologies, different definitions for inclination and anteversion, several reference planes and distinct patient positions. All available studies lack uniformity in cup orientation assessment; therefore it is impossible to reach consensus on optimal cup orientation. Using navigation systems for placement of the cup is inevitably flawed when using different definitions in the preoperative planning, peroperative placement and postoperative evaluation. Further methodological development is required to assess cup orientation. Consequently, the postoperative assessment should be uniform, thus differentiating between anterior and posterior dislocation, use the same definitions for inclination and anteversion with the same reference plane and with the patient in the same position.

  13. Acetabular Dysplasia and Surgical Approaches Other Than Direct Anterior Increases Risk for Malpositioning of the Acetabular Component in Total Hip Arthroplasty

    DEFF Research Database (Denmark)

    Gromov, Kirill; Greene, Meridith E; Huddleston, James I

    2016-01-01

    BACKGROUND: Persistent acetabular dysplasia (AD) after periacetabular osteotomy has been hypothesized to increase the risk for malpositioning of the acetabular component. In this study, we investigate whether AD is an independent risk factor for cup malpositioning during primary total hip...... arthroplasty (THA). METHODS: Patient demographics, surgical approach, presence of AD assessed using the lateral center-edge angle, and acetabular cup positioning determined using Martell Hip Analysis Suite were investigated in 836 primary THA patients enrolled in a prospective multicenter study. RESULTS: We...

  14. Precision of radiostereometric analysis (RSA) of acetabular cup stability and polyethylene wear improved by adding tantalum beads to the liner

    DEFF Research Database (Denmark)

    Nebergall, Audrey K; Rader, Kevin; Palm, Henrik

    2015-01-01

    segment to measure wear and acetabular cup stability. The standard deviation multiplied by the critical value (from a t distribution) established the precision of each method. Results - Due to the imprecision of the automated edge detection, the shell-only method was least desirable. The shell + liner...

  15. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

    Science.gov (United States)

    Craiovan, B; Weber, M; Worlicek, M; Schneider, M; Springorum, H R; Zeman, F; Grifka, J; Renkawitz, T

    2016-06-01

    The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane. The mean difference between the radiographic and the 3D-CT measurements was - 1.4° ± 3.9° for inclination and 0.8°± 7.9° for anteversion with excellent correlation for inclination (r = 0.81, p cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future. • Measuring acetabular cup orientation on anteroposterior radiographs of the hip after THA is a helpful procedure in everyday clinical practice as a first-line imaging modality• CT remains the golden standard to accurately determine acetabular cup position.• Future measuring on radiographs for cup orientation after THA should account for integration of the pelvic tilt in order to maximize the measurement accuracy. Citation Format: • Craiovan B, Weber M, Worlicek M et al. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?. Fortschr Röntgenstr 2016; 188: 574 - 581. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Bipolar hip arthroplasty as salvage treatment for loosening of the acetabular cup with significant bone defects

    Directory of Open Access Journals (Sweden)

    Ghanem, Mohamed

    2016-04-01

    Full Text Available Introduction: Revision arthroplasty of the hip is becoming increasingly important in recent years. Early primary arthroplasty and longer life expectancy of the patients increases the number of revision surgery. Revision surgery of hip arthroplasty is major surgery for the patients, especially the elderly, with significant risks concerning the general condition of the patient. The aim of this work is to evaluate the outcome of bipolar hip arthroplasty as a salvage procedure for treatment of loosening of the acetabular cup with significant acetabular bone defects after total hip replacement (THR in multi-morbid patients.Patients and methods: During the period from January 1 2007 to December 31 2011 19 revision hip surgeries were performed in , in which the loosened acetabular cup was replaced by a bipolar head. The examined patient group consisted exclusively of female patients with an average of 75 years. The predominant diagnosis was “aseptic loosening” (84.2%. All patients in our study were multi-morbid. We decided to resort to bipolar hip arthroplasty due to the compromised general condition of patients and the major acetabular bone defects, which were confirmed intraoperatively. The postoperative follow-up ranged from 0.5 to 67 months (average 19.1 months. Results: Evaluation of the modified Harris Hip Score showed an overall improvement of the function of the hip joint after surgery of approximately 45%.Surgery was less time consuming and thus adequate for patients with significantly poor general health condition. We noticed different complications in a significant amount of patients (68.4%. The most common complication encountered was the proximal migration of the bipolar head.The rate of revision following the use of bipolar hip arthroplasty in revision surgery of the hip in our patients was high (21%. Despite the high number of complications reported in our study, we have noticed significant improvement of hip joint function as well

  17. Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

    Science.gov (United States)

    Schwarz, T; Weber, M; Wörner, M; Renkawitz, T; Grifka, J; Craiovan, B

    2017-05-01

    Accurate assessment of cup orientation on postoperative radiographs is essential for evaluating outcome after THA. However, accuracy is impeded by the deviation of the central X-ray beam in relation to the cup and the impossibility of measuring retroversion on standard pelvic radiographs. In an experimental trial, we built an artificial cup holder enabling the setting of different angles of anatomical anteversion and inclination. Twelve different cup orientations were investigated by three examiners. After comparing the two methods for radiographic measurement of the cup position developed by Lewinnek and Widmer, we showed how to differentiate between anteversion and retroversion in each cup position by using a second plane. To show the effect of the central beam offset on the cup, we X-rayed a defined cup position using a multidirectional central beam offset. According to Murray's definition of anteversion and inclination, we created a novel corrective procedure to balance measurement errors caused by deviation of the central beam. Measurement of the 12 different cup positions with the Lewinnek's method yielded a mean deviation of [Formula: see text] (95 % CI 1.3-2.3) from the original cup anteversion. The respective deviation with the Widmer/Liaw's method was [Formula: see text] (95 % CI 2.4-4.0). In each case, retroversion could be differentiated from anteversion with a second radiograph. Because of the multidirectional central beam offset ([Formula: see text] cm) from the acetabular cup in the cup holder ([Formula: see text] anteversion and [Formula: see text] inclination), the mean absolute difference for anteversion was [Formula: see text] (range [Formula: see text] to [Formula: see text] and [Formula: see text] (range [Formula: see text] to [Formula: see text] for inclination. The application of our novel mathematical correction of the central beam offset reduced deviation to a mean difference of [Formula: see text] for anteversion and [Formula: see text

  18. Quantification of Wear and Deformation in Different Configurations of Polyethylene Acetabular Cups Using Micro X-ray Computed Tomography

    Directory of Open Access Journals (Sweden)

    Saverio Affatato

    2017-03-01

    Full Text Available Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations.

  19. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    Science.gov (United States)

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (Pcup coverage (Pearson r=0.761, Pcup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  20. Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni F; Walia, Amit; Gonzalez, Mark; Bobko, Aimee

    2017-08-01

    Management of segmental rim defects and bone mineral density (BMD) loss in the elderly prior to total hip replacement is unclear within classification systems for acetabular bone loss. In this study, our objectives were (1) to understand how a reduction in BMD in the elderly affects the oversizing of a press-fit cup for primary fixation and (2) to evaluate whether the location of the segmental defect affected cup fixation. A finite element (FE) model was used to simulate and evaluate cup insertion and fixation in the context of segmental rim defects. We focused on the distribution of patients over age 70 and used BMD (estimated from CT) as a proxy for aging's implications on THR and used probabilistic FE analysis to understand how BMD loss affects oversizing of a press-fit cup. A cup oversized by 1.10 ± 0.28 mm provides sufficient fixation and lower stresses at the cup-bone interface for elderly patients. Defects in the anterior column and posterior column both required the same mean insertion force for cup seating of 84% (taken as an average of 2 anterior column and 2 posterior column defects) compared to the control configuration, which was 5% greater than the insertion force for a superior rim defect and 12% greater than the insertion force for an inferior rim defect. A defect along the superior or inferior rim had a minimal effect on cup fixation, while a defect in the columns created cup instability and increased stress at the defect location.

  1. Wear analysis by applying a pin-disc configuration to phemoral head and acetabular cup Análisis del desgaste de la articulación cabeza femoral–copa acetabular mediante simulación experimental con máquina perno-disco

    Directory of Open Access Journals (Sweden)

    Beltrán-Fernandez Juan Alfonso

    2008-07-01

    Full Text Available This work determines a prosthetic hip system’s life-span, focusing on a Mexican phenotype. The total sliding equivalent distance for the system was determined, as well as the loading regime under which the femoral component and the acetabular cup were subjected in normal operating conditions. An experimental tribology essay was then performed to simulate the wearing of the components in a Pin over Disc machine. This assay (for which the test specimens were manufactured in medical grade stainless steel AISI-ASTM 316L for the femoral component and high density polyethylene for the acetabular cup was aimed at simulating wear conditions involved in 10 years of continuous operation. A numerical simulation of operational conditions (using the finite element method was performedIn for establishing assay loading conditions to accurately determine where the loads should be applied. The tribology assay led to quantifying the volumetric loss of materials for the system being analysed. It can be concluded that the methodology proposed in this work for estimating the life-span of a prosthetic hip system was valid and accurate by comparing the results with those found in the literature. A statistical validation of the proposed method is plaaned for the future. Key words: Design life; femoral component; acetabular cup; Mexican phenotype; pin-disc configuration.Este trabajo presenta un estudio que permite establecer la vida útil esperada de un sistema prostético de cadera para el caso del fenotipo mexicano. En primera instancia se determinó la distancia total equivalente de deslizamiento y las condiciones de carga entre el componente femoral y la copa acetabular bajo condiciones normales de carga. Posteriormente, se desarrolló una simulación experimental para la realización de un ensayo tribológico en una máquina de desgaste del tipo Perno sobre Disco (Pin on Disk, POD. Este ensayo sometió al conjunto fabricado en acero inoxidable AISI

  2. [Osteosynthesis and cup revision in periprosthetic acetabulum fractures using a Kocher-Langenbeck approach].

    Science.gov (United States)

    Schwabe, P; Märdian, S; Perka, C; Schaser, K-D

    2016-04-01

    Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.

  3. Trabecular metal acetabular components in primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Laaksonen, Inari; Lorimer, Michelle; Gromov, Kirill

    2018-01-01

    Background and purpose - Trabecular metal (TM) cups have demonstrated favorable results in acetabular revision and their use in primary total hip arthroplasty (THA) is increasing. Some evidence show that TM cups might decrease periprosthetic infection (PPI) incidence. We compared the survivorship...... of TM cups with that of other uncemented cups in primary THA, and evaluated whether the use of TM cups is associated with a lower risk of PPI. Patients and methods - 10,113 primary THAs with TM cup and 85,596 THAs with other uncemented cups from 2 high-quality national arthroplasty registries were...

  4. Fixation strength analysis of cup to bone material using finite element simulation

    NARCIS (Netherlands)

    Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; Van Der Heide, Emile

    2016-01-01

    Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw

  5. Does Increased Coefficient of Friction of Highly Porous Metal Increase Initial Stability at the Acetabular Interface?

    Science.gov (United States)

    Goldman, Ashton H; Armstrong, Lucas C; Owen, John R; Wayne, Jennifer S; Jiranek, William A

    2016-03-01

    Highly porous metal acetabular components illustrate a decreased rate of aseptic loosening in short-term follow-up compared with previous registry data. This study compared the effect of component surface roughness at the bone-implant interface and the quality of the bone on initial pressfit stability. The null hypothesis is that a standard porous coated acetabular cup would show no difference in initial stability as compared with a highly porous acetabular cup when subjected to a bending moment. Second, would bone mineral density (BMD) be a significant variable under these test conditions. In a cadaveric model, acetabular cup micromotion was measured during a 1-time cantilever bending moment applied to 2 generations of pressfit acetabular components. BMD data were also obtained from the femoral necks available for associated specimen. The mean bending moment at 150 μm was not found to be significantly different for Gription (24.6 ± 14.0 N m) cups vs Porocoat (25 ± 10.2 N m; P > .84). The peak bending moment tolerated by Gription cups (33.9 ± 20.3 N m) was not found to be significantly different from Porocoat (33.5 ± 12.2 N m; P > .92). No correlation between BMD and bending moment at 150 μm of displacement could be identified. The coefficient of friction provided by highly porous metal acetabular shells used in this study did not provide better resistance to migration under bending load when compared with a standard porous coated component. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

    Science.gov (United States)

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-02-01

    Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41-78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ -1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2-10) years. Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were "at risk" (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the 10 cases were "at risk" in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3-48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually.

  7. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    International Nuclear Information System (INIS)

    Werner, Clement M.L.; Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H.; Ruckstuhl, Thomas; Bouaicha, Samy

    2011-01-01

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE ( 12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  8. Modified Harrington Procedure for Acetabular Insuficiency Due to Metastatic Malignant Disease

    Directory of Open Access Journals (Sweden)

    WI Faisham

    2009-05-01

    Full Text Available Extensive peri-acetabular osteolysis caused by malignant disease process is a major surgical challenge as conventional hip arthroplasty is not adequate. We describe a modified use of the Harrington procedure for acetabular insufficiency secondary to metastatic disease in twelve patients. The procedures include application of multiple threaded pins to bridge the acetabular columns, anti-protrusio cage and cemented acetabular cup. Eleven patients were able to walk pain free and achieved a mean Musculoskeletal Tumour Society Functional Score of 80 (range, 68 to 86.

  9. R3 Cup Does Not Have a High Failure Rate in Conventional Bearings: A Minimum of 5-Year Follow-Up.

    Science.gov (United States)

    Teoh, Kar H; Whitham, Robert D J; Golding, David M; Wong, Jenny F; Lee, Paul Y F; Evans, Aled R

    2018-02-01

    The R3 cementless acetabular system was first marketed in Australia and Europe in 2007. Previous papers have shown high failure rates of the R3 cup with up to 24% with metal-on-metal bearing. There are currently no medium term clinical results on this cup. The aim of the study is to review our results of the R3 acetabular cup with conventional bearings with a minimum of 5-year follow-up. Patients who were implanted with the R3 acetabular cup were identified from our center's arthroplasty database. A total of 293 consecutive total hip arthroplasties were performed in 286 patients. The primary outcome was revision. The secondary outcomes were the Oxford Hip Scores (OHS) and radiographic evaluation. The mean age of the patients was 69.4 years. The mean preoperative OHS was 23 (range 10-34) and the mean OHS was 40 (range 33-48) at the final follow-up. Radiological evaluation showed an excellent ARA score in all patients at 5 years. None of the R3 cups showed osteolysis at the final follow-up. There were 3 revisions in our series, of which 2 R3 cups were revised. The risk of revision was 1.11% at 5 years. Our experience of using the R3 acetabular system with conventional bearings showed high survivorship and is consistent with the allocated Orthopaedic Data Evaluation Panel rating of 5A* as rated in 2015 in the United Kingdom. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Computer assisted determination of acetabular cup orientation using 2D-3D image registration

    International Nuclear Information System (INIS)

    Zheng, Guoyan; Zhang, Xuan

    2010-01-01

    2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. A new formulation for determination of post-operative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 ± 0.7 (range from 0.1 to 2.0 ) for inclination and 1.7 ± 1.2 (range from 0.0 to 3.9 ) for anteversion, taking the measurements from post-operative CT images as ground truths. Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of post-operative cup orientation and measurement of pelvic tilt and rotation. (orig.)

  11. Design optimization of cementless metal-backed cup prostheses using the concept of functionally graded material

    Energy Technology Data Exchange (ETDEWEB)

    Hedia, H S; El-Midany, T T; Shabara, M A N; Fouda, N [Production Engineering and M/C Design Department, Faculty of Engineering, Mansoura University, Mansoura (Egypt)

    2006-09-15

    Metal backing has been widely used in acetabular cup design. A stiff backing for a polyethylene liner was initially believed to be mechanically favourable. Yet, recent studies of the load transfer around acetabular cups have shown that a stiff backing causes two problems. It generates higher stress peaks around the acetabular rim than those caused by full polyethylene cups and reduces the stresses transferred to the dome of the acetabulum causing stress shielding. The aim of this study is to overcome these two problems by improving the design of cementless metal-backed acetabular cups using the two-dimensional functionally graded material (FGM) concept through finite-element analysis and optimization techniques. It is found that the optimal 2D FGM model must have three bioactive materials of hydroxyapatite, Bioglass and collagen. This optimal material reduces the stress shielding at the dome of the acetabulum by 40% and 37% compared with stainless steel and titanium metal backing shells, respectively. In addition, using the 2D FGM model reduces the maximum interface shear stress in the bone by 31% compared to the titanium metal backing shell.

  12. Acetabular QCT in Total Hip Arthroplasty - a reliability study using porcine hips

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Overgaard, Soren; Torfing, Trine

    and reliability of bone mineral density measurements (BMD) in close proximity of the acetabular cup using SECT and DECT images and 3D segmentation software. Materials and methods 22 acetabular cups (12 cemented, 10 un-cemented) were inserted in porcine hip specimens ex vivo. A femoral stem was attached to each...... difference between the double measurements in SECT was 8 mg/cm3 (p=0.64) and 2 mg/cm3 in DECT (p=0.6). In the cemented concept the differences were 33 mg/cm3 (p=0.054) and 11 mg/cm3 (p=0.014), respectively. ICC was >0.90 regardless of scan mode and cup type. In both cup types the Bland-Altman limits...... of agreement were wider in SECT (uncemented: -95 to 111; cemented: -86 to 153) compared with DECT (uncemented: -28 to 23; cemented: -21 to 44). Conclusion There were no statistically significant reliability differences between SECT and DECT, but results suggest that the agreement of DECT is better than...

  13. Relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index, and medial acetabular bone stock

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Clement M.L. [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland); University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Copeland, Carol E.; Stromberg, Jeff; Turen, Clifford H. [University of Maryland Medical Systems, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States); Ruckstuhl, Thomas; Bouaicha, Samy [Balgrist University Hospital Zurich, Department of Orthopaedics, Zurich (Switzerland)

    2011-11-15

    Knowledge of acetabular anatomy is crucial for cup positioning in total hip replacement. Medial wall thickness of the acetabulum is known to correlate with the degree of developmental dysplasia of the hip (DDH). No data exist about the relationship of routinely used radiographic parameters such as Wiberg's lateral center edge angle (LCE-angle) or Lequesne's acetabular index (AI) with thickness of the medial acetabular wall in the general population. The aim of our study was to clarify the relationship between LCE, AI, and thickness of the medial acetabular wall. Measurements on plain radiographs (LCE and AI) and axial CT scans (quadrilateral plate acetabular distance QPAD) of 1,201 individuals (2,402 hips) were obtained using a PACS imaging program and statistical analyses were performed. The mean thickness of the medial acetabulum bone stock (QPAD) was 1.08 mm (95% CI: 1.05-1.10) with a range of 0.1 to 8.8 mm. For pathological values of either the LCE (<20 ) or the AI (>12 ) the medial acetabular wall showed to be thicker than in radiological normal hips. The overall correlation between coxometric indices and medial acetabular was weak for LCE (r =-0.21. 95% CI [-0.25, -0.17]) and moderate for AI (r = 0.37, [0.33, 0.41]). We did not find a linear relationship between Wiberg's lateral center edge angle, Lequesne's acetabular index and medial acetabular bone stock in radiological normal hips but medial acetabular wall thickness increases with dysplastic indices. (orig.)

  14. Revision of migrated pelvic acetabular components in THA with or without vascular involvement

    Directory of Open Access Journals (Sweden)

    Ștefan Cristea

    2016-05-01

    Full Text Available Purpose. The literature describes a high rate of mortality in cases of intrapelvic acetabular component migration, which is a rare but serious complication. Our aim is to establish and propose a treatment protocol according to our results and experience. Material and Methods. We performed eight (8 total hip revisions with acetabular cup migration between 2006 and 2012. A vascular graft was needed in four (4 of these cases. Two (2 cases were revisions after a spacer for infected arthroplasties. The protocol included the following: X-Ray examination (frontal and lateral views, CT angiography, a biological evaluation, a suitable pre-operative plan, at least six (6 units of blood stock, an experienced anesthesiologist, an experienced surgical team that included a vascular surgeon and a versatile arsenal of revision prostheses, bone grafts and vascular grafts. The anterolateral approach was generally used for hip revisions and the retroperitoneal approach in the dorsal decubitus position was used when vascular risk was involved. Results: The acetabular defect was reconstructed using bone grafts and tantalum revision cups in 4 cases, Burch-Schneider cages in 2 cases, a Kerboull ring in 1 case and a cementless oblong cup (Cotyle Espace in 1 case. In 4 cases, an iliac vessel graft procedure was conducted by the vascular surgeon. All patients survived the revision procedures and returned regularly for subsequent check-ups, during which they did not show any septic complications. Conclusions: Intrapelvic acetabular cup migration is a rare but serious complication that can occur after total hip arthroplasty in either septic or aseptic cases. An experienced, multidisciplinary team of surgeons should be involved in planning and conducting such complicated revisions.

  15. Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Zilkens C

    2011-03-01

    Full Text Available Abstract The aim of this study was to evaluate the initial acetabular implant stability and late acetabular implant migration in press fit cups combined with screw fixation of the acetabular component in order to answer the question whether screws are necessary for the fixation of the acetabular component in cementless primary total hip arthroplasty. One hundred and seven hips were available for follow-up after primary THA using a cementless, porous-coated acetabular component. A total of 631 standardized radiographs were analyzed digitally by the "single-film-x-ray-analysis" method (EBRA. One hundred 'and one (94.4% acetabular components did not show significant migration of more than 1 mm. Six (5.6% implants showed migration of more than 1 mm. Statistical analysis did not reveal preoperative patterns that would identify predictors for future migration. Our findings suggest that the use of screw fixation for cementless porous- coated acetabular components for primary THA does not prevent cup migration.

  16. [Misinterpretation of the anteversion in computer-assisted acetabular cup navigation as a result of a simplified palpation method of the frontal pelvic plane].

    Science.gov (United States)

    Richolt, J A; Rittmeister, M E

    2006-01-01

    Computer assisted navigation of the acetabular cup in THR requires reliable digitalisation of bony landmarks defining the frontal pelvic plane by user driven palpation. According to the system recommendations the subcutaneous fat should be held aside during epicutaneous digitalization. To improve intraoperative practicability this is often neglected in the symphysis area. In these cases the fat is just compressed and not pushed aside. In this study soft tissue thickness was assessed by ultrasound and pelvic geometry was measured in 72 patients to quantify potential misinterpretation of cup anteversion triggered by the simplified palpation. As reference we employed data of the same patients that had been acquired by recommended palpation. Anteversion misinterpretation averaged at 8.2 degrees with extremes from 2 to 24 degrees. There were no correlations between soft tissue thickness or misinterpretation and body weight, height and pelvic size. Anteversion misinterpretation was highly significant worse compared to the reference data. In 31 % of the patients the anteversion misinterpretation of a navigation system would have been wrong by over 10 degrees and in 81 % over 5 degrees . Therefore the simplified palpation should not be utilized. For epicutaneous digitalization of the bony landmarks it is mandatory to push the subcutaneous fat aside.

  17. Is the cup orientation different in bilateral total hip arthroplasty with right-handed surgeons using posterolateral approach?

    Science.gov (United States)

    Song, Xinggui; Ni, Ming; Li, Heng; Li, Xin; Li, Xiang; Fu, Jun; Chen, Jiying

    2018-05-23

    The impact of surgeon handedness on acetabular cup orientation in total hip arthroplasty (THA) is not well studied. The aim of our study is to investigate the difference of cup orientation in bilateral THA performed by right-handed surgeons using posterolateral approach and which cup could be fitter to Lewinneck's safe zone. The study consisted of 498 patients that underwent bilateral THA by three right-handed surgeons in our hospital. Postoperative acetabular cup anteversion and abduction on an anteroposterior pelvic radiograph were measured by Orthoview software (Orthoview LLC, Jacksonville, Florida). Furthermore, the percentage of cup placement within the safe zone was compared. The mean anteversion was 25.28 (25.28° ± 7.16°) in left THA and 22.01 (22.01° ± 6.35°) in right THA (p cup was positioned in Lewinnek's safe zone in 52% for anteversion, 87% for abduction, and 46% for both anteversion and abduction. But the cup placement within Lewinnek's safe zone was 71, 88, and 62% in the right side, respectively. There were significant differences in the percentage of acetabular cup placement within the safe zone for anteversion (p cup inclination and anteversion in bilateral THA and that the placement of cup performed by dominant hands of surgeons is more accurate than that performed by non-dominant sides.

  18. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  19. Factors influencing initial cup stability in total hip arthroplasty.

    Science.gov (United States)

    Amirouche, Farid; Solitro, Giovanni; Broviak, Stefanie; Gonzalez, Mark; Goldstein, Wayne; Barmada, Riad

    2014-12-01

    One of the main goals in total hip replacement is to preserve the integrity of the hip kinematics, by well positioning the cup and to make sure its initial stability is congruent and attained. Achieving the latter is not trivial. A finite element model of the cup-bone interface simulating a realistic insertion and analysis of different scenarios of cup penetration, insertion, under-reaming and loading is investigated to determine certain measurable factors sensitivity to stress-strain outcome. The insertion force during hammering and its relation to the cup penetration during implantation is also investigated with the goal of determining the initial stability of the acetabular cup during total hip arthroplasty. The mathematical model was run in various configurations to simulate 1 and 2mm of under-reaming at various imposed insertion distances to mimic hammering and insertion of cup insertion into the pelvis. Surface contact and micromotion at the cup-bone interface were evaluated after simulated cup insertion and post-operative loading conditions. The results suggest a direct correlation between under-reaming and insertion force used to insert the acetabular cup on the micromotion and fixation at the cup-bone interface. While increased under-reaming and insertion force result in an increase amount of stability at the interface, approximately the same percentage of surface contact and micromotion reduction can be achieved with less insertion force. We need to exercise caution to determine the optimal configuration which achieves a good conformity without approaching the yield strength for bone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Influence of Surgical Approach on Pelvic Lift in Hip Arthroplasty During Cup Insertion.

    Science.gov (United States)

    Brodt, Steffen; Windisch, Christoph; Krakow, Linda; Nowack, Dimitri; Matziolis, Georg

    2017-07-01

    The position of the acetabular cup is a major factor in the long-term outcome of total hip arthroplasty (THA). Malpositioning of the acetabular cup frequently has been reported with the use of a minimally invasive implantation technique. It remains unclear whether the limited visibility or the increased retractor traction and thus tilting of the pelvis during cup implantation is the cause. This study investigated the influence of iatrogenically related pelvic lift using an anterolateral minimally invasive THA technique. In a group of 30 consecutive patients who underwent THA via a minimally invasive anterolateral approach, iatrogenic lifting of the pelvis was measured with a smartphone using a 3-axis accelerometer and compared with patients in a historical age- and sex-matched control group who underwent THA using a transgluteal approach. Postoperatively, the inclination and anteversion of the cup was determined on pelvic radiographs. In the anterolateral group, the pelvis was lifted by a maximum of 6.3° and by an average of 3.9° when the acetabular cup was impacted; no difference was noted compared with the transgluteal group. In contrast, the cups in the anterolateral group showed significantly increased inclination and reduced anteversion. In both techniques, the iatrogenic tilting of the pelvis at the time of cup implantation occurred to a comparable extent. Therefore, the significant differences in postoperative radiographs cannot be attributed to increased retractor traction on exposure of the acetabulum, which means that the limited visibility must be responsible. [Orthopedics. 2017; 40(4):e589-e593.]. Copyright 2017, SLACK Incorporated.

  1. Pelvic Incidence: A Predictive Factor for Three-Dimensional Acetabular Orientation—A Preliminary Study

    Directory of Open Access Journals (Sweden)

    Christophe Boulay

    2014-01-01

    Full Text Available Acetabular cup orientation (inclination and anteversion is a fundamental topic in orthopaedics and depends on pelvis tilt (positional parameter emphasising the notion of a safe range of pelvis tilt. The hypothesis was that pelvic incidence (morphologic parameter could yield a more accurate and reliable assessment than pelvis tilt. The aim was to find out a predictive equation of acetabular 3D orientation parameters which were determined by pelvic incidence to include in the model. The second aim was to consider the asymmetry between the right and left acetabulae. Twelve pelvic anatomic specimens were measured with an electromagnetic Fastrak system (Polhemus Society providing 3D position of anatomical landmarks to allow measurement of acetabular and pelvic parameters. Acetabulum and pelvis data were correlated by a Spearman matrix. A robust linear regression analysis provided prediction of acetabulum axes. The orientation of each acetabulum could be predicted by the incidence. The incidence is correlated with the morphology of acetabula. The asymmetry of the acetabular roof was correlated with pelvic incidence. This study allowed analysis of relationships of acetabular orientation and pelvic incidence. Pelvic incidence (morphologic parameter could determine the safe range of pelvis tilt (positional parameter for an individual and not a group.

  2. The effect of cup outer sizes on the contact mechanics and cement fixation of cemented total hip replacements.

    Science.gov (United States)

    Hua, Xijin; Li, Junyan; Wang, Ling; Wilcox, Ruth; Fisher, John; Jin, Zhongmin

    2015-10-01

    One important loosening mechanism of the cemented total hip arthroplasty is the mechanical overload at the bone-cement interface and consequent failure of the cement fixation. Clinical studies have revealed that the outer diameter of the acetabular component is a key factor in influencing aseptic loosening of the hip arthroplasty. The aim of the present study was to investigate the influence of the cup outer diameter on the contact mechanics and cement fixation of a cemented total hip replacement (THR) with different wear penetration depths and under different cup inclination angles using finite element (FE) method. A three-dimensional FE model was developed based on a typical Charnley hip prosthesis. Two acetabular cup designs with outer diameters of 40 and 43 mm were modelled and the effect of cup outer diameter, penetration depth and cup inclination angle on the contact mechanics and cement fixation stresses in the cemented THR were studied. The results showed that for all penetration depths and cup inclination angles considered, the contact mechanics in terms of peak von Mises stress in the acetabular cup and peak contact pressure at the bearing surface for the two cup designs were similar (within 5%). However, the peak von Mises stress, the peak maximum principal stress and peak shear stress in the cement mantle at the bone-cement interface for the 43 mm diameter cup design were predicted to be lower compared to those for the 40 mm diameter cup design. The differences were predicted to be 15-19%, 15-22% and 18-20% respectively for different cup penetration depths and inclination angles, which compares to the clinical difference of aseptic loosening incidence of about 20% between the two cup designs. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Use of iPhone technology in improving acetabular component position in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Xiau Wei Tay, MBBS

    2017-09-01

    Full Text Available Improper acetabular cup positioning is associated with high risk of complications after total hip arthroplasty. The aim of our study is to objectively compare 3 methods, namely (1 free hand, (2 alignment jig (Sputnik, and (3 iPhone application to identify an easy, reproducible, and accurate method in improving acetabular cup placement. We designed a simple setup and carried out a simple experiment (see Method section. Using statistical analysis, the difference in inclination angles using iPhone application compared with the freehand method was found to be statistically significant (F[2,51] = 4.17, P = .02 in the “untrained group”. There is no statistical significance detected for the other groups. This suggests a potential role for iPhone applications in junior surgeons in overcoming the steep learning curve.

  4. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    Science.gov (United States)

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for

  5. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    Science.gov (United States)

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes

  6. Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

    Science.gov (United States)

    Tijou, Antoine; Rosi, Giuseppe; Hernigou, Philippe; Flouzat-Lachaniette, Charles-Henri; Haïat, Guillaume

    2017-12-27

    The acetabular cup (AC) implant stability is determinant for the success of cementless hip arthroplasty. A method based on the analysis of the impact force applied during the press-fit insertion of the AC implant using a hammer instrumented with a force sensor was developed to assess the AC implant stability. The aim of the present study was to investigate the performance of a method using a hammer equipped with strain sensors to retrieve the AC implant stability. Different AC implants were inserted in five bovine samples with different stability conditions leading to 57 configurations. The AC implant was impacted 16 times by the two hammers consecutively. For each impact; an indicator I S (respectively I F ) determined by analyzing the time variation of the signal corresponding to the averaged strain (respectively force) obtained with the stress (respectively strain) hammer was calculated. The pull-out force F was measured for each configuration. F was significantly correlated with I S (R² = 0.79) and I F (R² = 0.80). The present method has the advantage of not modifying the shape of the hammer that can be sterilized easily. This study opens new paths towards the development of a decision support system to assess the AC implant stability.

  7. Clinical and Radiological Results over the Medium Term of Isolated Acetabular Revision

    Directory of Open Access Journals (Sweden)

    Nicola Piolanti

    2014-01-01

    Full Text Available Acetabular cup loosening is associated with pain, reduced function, and instability of the implant. If such event happens while the femoral implant is in a satisfactory position and is well fixed to the bone, isolated acetabular revision surgery is indicated. The aim of this single-center retrospective study was to evaluate the clinical and radiological results over the medium term (12-month follow-up mean 36, max 60 of isolated acetabular revisions surgery using a porous hemispheric revision shell matched with a cemented all-poly cup and large diameter femoral head (>32. 33 patients were enrolled. We collect any relevant data from the clinical board. Routine clinical and radiographic examinations were performed preoperatively; the postoperative follow-up was made at 1, 3, and 6 months and yearly thereafter. At the last available follow-up, we report satisfactory improvement of functional scores in all the patients; 2 patients (6.1% showed thigh pain and only 4 hips (12.11% presented mild groin pain; all the femoral components are well fixed and there were no potential or pending rerevisions. With bias due to the follow-up and to the retrospective design of the study, we report clinical, functional, and radiological satisfactory results.

  8. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  9. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    Directory of Open Access Journals (Sweden)

    Masanori Fujii

    2017-01-01

    Full Text Available Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months. The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE angle and the bone coverage index (BCI from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3% and the minimum cup-CE angle was −9.2° (BCI: 48.8%. Thin radiolucent lines were observed in 5 hips (2.3%, which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50% was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%.

  10. Migration of the Duraloc cup after 5 years.

    Science.gov (United States)

    Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard

    2008-12-01

    The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).

  11. Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.

    Science.gov (United States)

    Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A

    2014-10-01

    Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and

  12. Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

    Science.gov (United States)

    Al-Amiry, Bariq; Mahmood, Sarwar; Krupic, Ferid; Sayed-Noor, Arkan

    2017-09-01

    Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

  13. High-precision measurements of cementless acetabular components using model-based RSA: an experimental study

    DEFF Research Database (Denmark)

    Baad-Hansen, Thomas; Kold, Søren; Kaptein, Bart L

    2007-01-01

    BACKGROUND: In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years...

  14. Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

    Science.gov (United States)

    Brodén, Cyrus; Olivecrona, Henrik; Maguire, Gerald Q; Noz, Marilyn E; Zeleznik, Michael P; Sköldenberg, Olof

    2016-01-01

    Background and Purpose. The gold standard for detection of implant wear and migration is currently radiostereometry (RSA). The purpose of this study is to compare a three-dimensional computed tomography technique (3D CT) to standard RSA as an alternative technique for measuring migration of acetabular cups in total hip arthroplasty. Materials and Methods. With tantalum beads, we marked one cemented and one uncemented cup and mounted these on a similarly marked pelvic model. A comparison was made between 3D CT and standard RSA for measuring migration. Twelve repeated stereoradiographs and CT scans with double examinations in each position and gradual migration of the implants were made. Precision and accuracy of the 3D CT were calculated. Results. The accuracy of the 3D CT ranged between 0.07 and 0.32 mm for translations and 0.21 and 0.82° for rotation. The precision ranged between 0.01 and 0.09 mm for translations and 0.06 and 0.29° for rotations, respectively. For standard RSA, the precision ranged between 0.04 and 0.09 mm for translations and 0.08 and 0.32° for rotations, respectively. There was no significant difference in precision between 3D CT and standard RSA. The effective radiation dose of the 3D CT method, comparable to RSA, was estimated to be 0.33 mSv. Interpretation. Low dose 3D CT is a comparable method to standard RSA in an experimental setting.

  15. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    Science.gov (United States)

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no

  16. Migration measurement of acetabular components in cementless total hip arthroplasty; Messung der Pfannenwanderung bei zementfreien Hueftimplantaten

    Energy Technology Data Exchange (ETDEWEB)

    Eckardt, A.; Karbowski, A.; Schwitalle, M.; Vogel, J.; Boden, F.; Seeleitner, C. [Mainz Univ. (Germany). Orthopaedische Klinik und Poliklinik; Schunk, K. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Mayrhofer, P. [Innsbruck Univ. (Austria). Inst. fuer Mathematik und Geometrie

    1998-08-01

    Migration measurements of acetabular components using a special computer aided method (EBRA = abbrevation for the German term ``Ein-Bild-Roentgenanalyse``) were performed to evaluate early results of the implants and predict aseptic loosening. Methods: Standard ap-radiographs of the pelvis were marked, specific points were digitised. Simulating the spatial situation the programme computes lengitudinal and vertical migration of the cup. 74 acetabular components in 71 patients could be studied by migration measurements. Results: 14 patients showed migration of more than 1 mm, which is the confidence limit of this method. Each of these patients showed diverse reasons for the migration, i.e. osteoporosis of the acetabular bone stock or problems concerning the surgical technique which means malposition of the cup or insufficient reaming of the bone. There were some patients with severe congenital dysplasia of the hip and in some cases the inclination angle of the cup was too great. Conclusion: The technique applied for measuring migration of acetabular components can be useful for evaluating early instability of the implant and can be helpful in detecting problems concerning the surgical technique. (orig.) [Deutsch] Mittels der Ein-Bild-Roentgenanalyse wurden Pfannenwanderungen nach Implantation von zementfreien, sphaerischen Hueftgelenkspfannen erfasst, um Praediktoren fuer die langfristige Prognose der Implantate zu evaluieren. Methoden: Nach Markierung von Referenzpunkten in den Beckenuebersichtsaufnahmen wurden diese digitalisiert, vom Programm verrechnet und die Wanderung des Implantats im Verlauf angegeben. Bei 71 Patienten wurden von 74 Pfannen ueber einen Mindestnachuntersuchungszeitraum von 12 Monaten Migrationsmessungen durchgefuehrt. Das Konfidenzintervall der Methode liegt bei <1 mm. Bei jedem dieser Patienten fanden sich Hinweise entweder auf ein schlechtes Knochenlager, auf operationsbedingte Probleme, wenn keine ausreichende Primaerstabilitaet der Pfanne

  17. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    Science.gov (United States)

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle cup-host bone fixation, especially when the cup-CE angle is small, such as cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  18. Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position.

    Science.gov (United States)

    Brodt, Steffen; Nowack, Dimitri; Jacob, Benjamin; Krakow, Linda; Windisch, Christoph; Matziolis, Georg

    2017-09-01

    Movement of the pelvis during implantation of total hip arthroplasty (THA) has a major influence on the positioning of the acetabular cup. Strong traction caused by retractors leads to iatrogenic pelvic lift and can thus be partly responsible for cup malpositioning. The objective of this study was to investigate such factors that influence pelvic lift. The dynamic movement of the pelvis was measured during implantation of THA in 67 patients. This was done by measuring the acceleration using the SensorLog app on a smartphone. At its maximum, the pelvis was lifted by an average of 6.7°. When impacting the press-fit cup, the surgical side was raised by 4.4° compared with the time of skin incision. This lift at the time of cup implantation correlates significantly with the body mass index and the patient's abdominal and pelvic circumference. Every surgeon performing THA must be aware of the pelvic lift during an operation. Especially in patients with a high body mass index, a large abdominal circumference, or a large pelvic circumference, there is an increased risk of malpositioning of the acetabular cup. When impacting the cup, we recommend releasing the traction of the retractor, so that the pelvis can tilt back into its natural position, and thus, the anticipated cup positioning can be implemented as exactly as possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Tailor-made Surgical Guide Reduces Incidence of Outliers of Cup Placement.

    Science.gov (United States)

    Hananouchi, Takehito; Saito, Masanobu; Koyama, Tsuyoshi; Sugano, Nobuhiko; Yoshikawa, Hideki

    2010-04-01

    Malalignment of the cup in total hip arthroplasty (THA) increases the risks of postoperative complications such as neck cup impingement, dislocation, and wear. We asked whether a tailor-made surgical guide based on CT images would reduce the incidence of outliers beyond 10 degrees from preoperatively planned alignment of the cup compared with those without the surgical guide. We prospectively followed 38 patients (38 hips, Group 1) having primary THA with the conventional technique and 31 patients (31 hips, Group 2) using the surgical guide. We designed the guide for Group 2 based on CT images and fixed it to the acetabular edge with a Kirschner wire to indicate the planned cup direction. Postoperative CT images showed the guide reduced the number of outliers compared with the conventional method (Group 1, 23.7%; Group 2, 0%). The surgical guide provided more reliable cup insertion compared with conventional techniques. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  20. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study.

    Science.gov (United States)

    Liu, Feng; Chen, Zhefeng; Gu, Yanqing; Wang, Qing; Cui, Weiding; Fan, Weimin

    2012-01-01

    Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM) total hips in simulators. Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC) wear test in simulators. The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3)/MC and 0.89 ± 0.04 mm(3)/MC (t = 48.43, p = 0.000). The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

  1. Clinical outcome of pedestal cup endoprosthetic reconstruction after resection of a peri-acetabular tumour

    NARCIS (Netherlands)

    Bus, M. P. A.; Boerhout, E. J.; Bramer, J. A. M.; Dijkstra, P. D. S.

    2014-01-01

    Peri-acetabular tumour resections and their subsequent reconstruction are among the most challenging procedures in orthopaedic oncology. Despite the fact that a number of different pelvic endoprostheses have been introduced, rates of complication remain high and long-term results are mostly lacking.

  2. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    LENUS (Irish Health Repository)

    Banks, Louisa N

    2012-02-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient\\'s weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  3. An unusual mode of failure of a tripolar constrained acetabular liner: a case report.

    Science.gov (United States)

    Banks, Louisa N; McElwain, John P

    2010-04-01

    Dislocation after primary total hip arthroplasty (THA) is the most commonly encountered complication and is unpleasant for both the patient and the surgeon. Constrained acetabular components can be used to treat or prevent instability after primary total hip arthroplasty. We present the case of a 42-year-old female with a BMI of 41. At 18 months post-primary THA the patient underwent further revision hip surgery after numerous (more than 20) dislocations. She had a tripolar Trident acetabular cup (Stryker-Howmedica-Osteonics, Rutherford, New Jersey) inserted. Shortly afterwards the unusual mode of failure of the constrained acetabular liner was noted from radiographs in that the inner liner had dissociated from the outer. The reinforcing ring remained intact and in place. We believe that the patient's weight, combined with poor abductor musculature caused excessive demand on the device leading to failure at this interface when the patient flexed forward. Constrained acetabular components are useful implants to treat instability but have been shown to have up to 42% long-term failure rates with problems such as dissociated inserts, dissociated constraining rings and dissociated femoral rings being sited. Sometimes they may be the only option left in difficult cases such as illustrated here, but still unfortunately have the capacity to fail in unusual ways.

  4. Radiological and migration results of the DURALOC(R)-cup after two years

    International Nuclear Information System (INIS)

    Juen, F.

    2000-10-01

    In 1997 a study was conduced concerning 69 consecutive patients, all of whom consisted of DURALOC(R) series 100 acetabular components. The clinical, radiological and migrational aspect of each component was investigated 2 and 4 years postoperatively. In addition to this, a further 92 cups were analyzed in an identical manner, again 2 years after implantation. This therefore equated to a total of 161 investigated cups after a follow up interval of 2 years. In 144 of these cases the cup was combined with a cementless hydroxyapatite coated Spotorno shaft, with the remaining 17 involving a cemented Link-shaft (Lubinus SP II). A 28 mm Biolox(R) ceramic head was constant in all cases. Clinical data for each cup was collected via completion of a standard examination form, while acetabular migration, both vertical and horizontal, was measured on serial radiographs by the computer assisted EBRA method. From analyses of collected data, it was clearly shown that the clinical results remained very good over the 2- and 4-year-periods however, from radiological evidence it was indicated that for the period 3-4 years postoperatively, an increasing amount of radiolucencies around the cups were apparent. There was clearly no correlation between clinical and migration results. From the data taken from 106 migration curves, the mean total migration over the initial two-year-period was calculated to be 0.88 mm. From analysis of a further 56 migration curves, the mean total migration within 4 years of implantation was assessed to be 1.23 mm, however a decreasing speed of migration over the final 2-year-period was indicated. Our results demonstrate that statements relating to migration results of particular cups are more accurate after four years. However, statements about mean migration values are possible after two years. A migration speed of 1 mm total migration within the first 2 years after operation was predictive for radiological loosening of the cup after four years (p=0

  5. Measuring acetabular cup orientation on antero-posterior radiographs of the hip after total hip arthroplasty with a vector arithmetic radiological method. Is it valid and verified for daily clinical practice?

    Energy Technology Data Exchange (ETDEWEB)

    Craiovan, B.; Weber, M.; Worlicek, M.; Schneider, M.; Springorum, H.R.; Grifka, J.; Renkawitz, T. [University Medical Center Regensburg, Bad Abbach/Regensburg (Germany). Orthopedic Surgery; Zeman, F. [University Medical Center Regensburg, Bad Abbach/Regensburg (Germany). Center for Clinical Studies

    2016-06-15

    The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane. The mean difference between the radiographic and the 3D-CT measurements was -1.4 ±3.9 for inclination and 0.8 ±7.9 for anteversion with excellent correlation for inclination (r=0.81, p < 0.001) and moderate correlation for anteversion (r=0.65, p < 0.001). The intraclass correlation coefficient for measurements on radiographs ranged from 0.98 (95%-CI: 0.98; 0.99) for the first observer to 0.94 (95%-CI: 0.92; 0.96) for the second observer. The interrater reliability was 0.96 (95%-CI: 0.93; 0.98) for inclination and 0.93 (95%-CI: 0.85; 0.96) for anteversion. The largest errors in measurements were associated with an extraordinary pelvic tilt. In order to get a valuable measurement for measuring cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future.

  6. A Novel Method for Assessment of Polyethylene Liner Wear in Radiopaque Tantalum Acetabular Cups

    DEFF Research Database (Denmark)

    Troelsen, Anders; Greene, Meridith E; Ayers, David C

    2015-01-01

    Conventional radiostereometric analysis (RSA) for wear is not possible in patients with tantalum cups. We propose a novel method for wear analysis in tantalum cups. Wear was assessed by gold standard RSA and the novel method in total hip arthroplasty patients enrolled in a randomized controlled...

  7. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study.

    Directory of Open Access Journals (Sweden)

    Feng Liu

    Full Text Available BACKGROUND: Recent studies have shown that the acetabular component frequently becomes deformed during press-fit insertion. The aim of this study was to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the Durom large head metal-on-metal (MOM total hips in simulators. METHODS: Six Durom cups impacted into reamed acetabula of fresh cadavers were used as the experimental group and another 6 size-paired intact Durom cups constituted the control group. All 12 Durom MOM total hips were put through a 3 million cycle (MC wear test in simulators. RESULTS: The 6 cups in the experimental group were all deformed, with a mean deformation of 41.78 ± 8.86 µm. The average volumetric wear rate in the experimental group and in the control group in the first million cycle was 6.65 ± 0.29 mm(3/MC and 0.89 ± 0.04 mm(3/MC (t = 48.43, p = 0.000. The ion levels of Cr and Co in the experimental group were also higher than those in the control group before 2.0 MC. However there was no difference in the ion levels between 2.0 and 3.0 MC. CONCLUSIONS: This finding implies that the non-modular acetabular component of Durom total hip prosthesis is likely to become deformed during press-fit insertion, and that the deformation will result in increased volumetric wear and increased ion release. CLINICAL RELEVANCE: This study was determined to explore the deformation of the Durom cup after implantation and to clarify the impact of deformation on wear and ion release of the prosthesis. Deformation of the cup after implantation increases the wear of MOM bearings and the resulting ion levels. The clinical use of the Durom large head prosthesis should be with great care.

  8. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.

    Science.gov (United States)

    Murphy, William S; Yun, Ho Hyun; Hayden, Brett; Kowal, Jens H; Murphy, Stephen B

    2018-02-01

    Cup malposition is a common cause of impingement, limitation of ROM, acceleration of bearing wear, liner fracture, and instability in THA. Previous studies of the safe zone based on plain radiographs have limitations inherent to measuring angles from two-dimensional projections. The current study uses CT to measure component position in stable and unstable hips to assess the presence of a safe zone for cup position in THA. (1) Does acetabular component orientation, when measured on CT, differ in stable components and those revised for recurrent instability? (2) Do CT data support historic safe zone definitions for component orientation in THA? We identified 34 hips that had undergone revision of the acetabulum for recurrent instability that also had a CT scan of the pelvis between August 2003 and February 2017. We also identified 175 patients with stable hip replacements who also had a CT study for preoperative planning and intraoperative navigation of the contralateral side. For each CT study, one observer analyzed major factors including acetabular orientation, femoral anteversion, combined anteversion (the sum of femoral and anatomic anteversion), pelvic tilt, total offset difference, head diameter, age, sex, and body mass index. These measures were then compared among stable hips, hips with cup revision for anterior instability, and hips with cup revision for posterior instability. We used a clinically relevant measurement of operative anteversion and inclination as opposed to the historic use of radiographic anteversion and inclination. The percentage of unstable hips in the historic Lewinnek safe zone was calculated, and a new safe zone was proposed based on an area with no unstable hips. Anteriorly unstable hips compared with stable hips had higher operative anteversion of the cup (44° ± 12° versus 31° ± 11°, respectively; mean difference, 13°; 95% confidence interval [CI], 5°-21°; p = 0.003), tilt-adjusted operative anteversion of the cup (40°

  9. Three-dimensional orientation and location-dependent varying rules of radiographic angles of the acetabular cup.

    Science.gov (United States)

    Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu

    2018-02-17

    The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.

  10. Low friction arthroplasty and dual mobility cup: a new gold standard.

    Science.gov (United States)

    Prudhon, Jean Louis; Verdier, Régis; Caton, Jacques H

    2017-03-01

    Low friction arthroplasty (LFA) introduced by Sir John Charnley was the gold standard for many years. Dislocation and infection are the first causes for early revision. Late failures are polyethylene (PE) wear and loosening. Due to dislocation risk we slowly switched to the use of LFA with dual mobility cups (DMC). The purposes of this study are (1) to assess whether our changes have improved outcomes and (2) what is the new gold standard? We selected from an observational registry of 1,091 cases of hybrid Charnley total hip arthroplasty (THA). The acetabular component was either DMC in 455 cases or fixed cup (FC) in 636 cases. Three dislocations (0.6%) occurred in the DMC group (none revised). In the FC group 54 dislocated (8.49%) and 20 were recurrent and underwent revision (revision rate 3.14%). In the DMC group, five acetabular and three femoral revisions were performed (revision rate for loosening 1.7%). In the FC group 19 cases underwent acetabular revision, and five cases had femoral component revised (revision rate for loosening 3.7%). Charnley's LFA has proven over 50 years of excellent survivorship. To decrease dislocation risk, one suggested increasing femoral head diameter. Gilles Bousquet proposed another way, namely, the DMC concept. Dislocation is no longer a critical issue with DMC as demonstrated in our series and main series. DMC in primary THA is still a subject of debate. Mid-term results do not demonstrate a higher rate of wear than LFA. What is the current gold standard? LFA was and is our current gold standard in association with a DMC.

  11. The dislocating hip replacement - revision with a dual mobility cup in 56 consecutive patients

    DEFF Research Database (Denmark)

    Jakobsen, Thomas; Kappel, Andreas; Hansen, Flemming

    2014-01-01

    INTRODUCTION: Recurrent dislocations of hip replacements are a difficult challenge. One treatment option for recurrent dislocations is the use of a dual mobility cup. The aim of this study was to retrospective investigate the effect of dual mobility cups as a treatment for recurrent dislocations...... with a Saturne dual mobility cup (Amplitude, Neyron, France). The mean follow-up period was 44 months (SD 30, range 0.1-119). RESULTS: One patient (1.8%) experienced a re-dislocation. Three patients (5.3%) had to be revised. One due to disintegration between the femoral head and inner shell, one due to loosening...... of the acetabular component, and one due to infection. Harris Hip Score improved from a mean of 76 before index surgery to 87 within one year after index surgery. CONCLUSION: This study advocates the use of a dual mobility cup for treatment of recurrent dislocations of THR. However, studies with a longer follow up...

  12. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  13. Development of a classification system for cup anemometers - CLASSCUP

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2003-01-01

    the objectives to quantify the errors associated with the use of cup anemometers, and to determine the requirements for an optimum design of a cup anemometer, and to develop a classification system forquantification of systematic errors of cup anemometers. The present report describes this proposed...... classification system. A classification method for cup anemometers has been developed, which proposes general external operational ranges to be used. Anormal category range connected to ideal sites of the IEC power performance standard was made, and another extended category range for complex terrain...... was proposed. General classification indices were proposed for all types of cup anemometers. As a resultof the classification, the cup anemometer will be assigned to a certain class: 0.5, 1, 2, 3 or 5 with corresponding intrinsic errors (%) as a vector instrument (3D) or as a horizontal instrument (2D...

  14. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position.

    Science.gov (United States)

    Williams, Sophie; Leslie, Ian; Isaac, Graham; Jin, Zhongmin; Ingham, Eileen; Fisher, John

    2008-08-01

    Clinical studies have indicated that the angular position of the acetabular cup may influence wear in metal-on-metal total hip bearings. A high cup angle in comparison to the anatomical position may lead to the head being constrained by the superior lateral surface and rim of the cup, thus potentially changing the location of the contact zone between the head and the cup. The aim of this study was to test the hypothesis that both a steep cup angle and a lateralized position of the head can increase head contact on the superior rim of the cup, with the consequence of increased wear. Hip-joint simulator studies of metal-on-metal bearings were undertaken with cup angles of 45 degrees and 55 degrees . The femoral head was either aligned to the center of the cup or placed in a position of microlateralization. Wear was measured gravimetrically over 5 million cycles. A steep cup angle of 55 degrees showed significantly higher long-term steady-state wear than a standard cup angle of 45 degrees (p < 0.01). The difference was fivefold. Microlateralization of the head resulted in a fivefold increase in steady-state wear compared with a centralized head. The combination of a steep cup angle and a microlateralized head increased the steady-state wear rate by tenfold compared with a standard cup angle with a centralized head. These studies support the hypothesis that both an increased cup angle and a lateral head position increase wear in metal-on-metal hip prostheses.

  15. Pelvic and acetabular fractures

    International Nuclear Information System (INIS)

    Mears, D.C.; Rubash, H.E.

    1986-01-01

    This treatise focuses primarily on the clinical aspects of diagnosis and treatments of pelvic and acetabular fractures. However, considerable attention is also paid to the radiographic diagnosis of trauma and postoperative effects. The book begins with a succinct review of pelvic and acetabular anatomy and pelvic biomechanics. It continues with a radiographic classification of pelvic injury, which will represent the major source of the book's interest for radiologists. The remainder of the book is concerned with clinical management of pelvic and acetabular trauma, including preoperative planning, surgical approaches, techniques of reduction, internal fixation, eternal fixation, post-operative care, and late problems. Even throughout this later portion of the book there are extensive illustrations, including plain radiographs, computed tomographic (CT) scans, reconstructed three-dimensional CT scans, and schematic diagrams of diverse pelvic and acetabular fractures and the elementary surgical techniques for their repair

  16. 3D Printing Aids Acetabular Reconstruction in Complex Revision Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Andrew J. Hughes

    2017-01-01

    Full Text Available Revision hip arthroplasty requires comprehensive appreciation of abnormal bony anatomy. Advances in radiology and manufacturing technology have made three-dimensional (3D representation of osseous anatomy obtainable, which provide visual and tactile feedback. Such life-size 3D models were manufactured from computed tomography scans of three hip joints in two patients. The first patient had undergone multiple previous hip arthroplasties for bilateral hip infections, resulting in right-sided pelvic discontinuity and a severe left-sided posterosuperior acetabular deficiency. The second patient had a first-stage revision for infection and recurrent dislocations. Specific metal reduction protocols were used to reduce artefact. The images were imported into Materialise MIMICS 14.12®. The models were manufactured using selective laser sintering. Accurate templating was performed preoperatively. Acetabular cup, augment, buttress, and cage sizes were trialled using the models, before being adjusted, and resterilised, enhancing the preoperative decision-making process. Screw trajectory simulation was carried out, reducing the risk of neurovascular injury. With 3D printing technology, complex pelvic deformities were better evaluated and treated with improved precision. Life-size models allowed accurate surgical simulation, thus improving anatomical appreciation and preoperative planning. The accuracy and cost-effectiveness of the technique should prove invaluable as a tool to aid clinical practice.

  17. Loosening After Acetabular Revision

    DEFF Research Database (Denmark)

    Beckmann, Nicholas A.; Weiss, Stefan; Klotz, Matthias C.M.

    2014-01-01

    The best method of revision acetabular arthroplasty remains unclear. Consequently, we reviewed the literature on the treatment of revision acetabular arthroplasty using revision rings (1541 cases; mean follow-up (FU) 5.7 years) and Trabecular Metal, or TM, implants (1959 cases; mean FU 3.7 years...

  18. Acetabular Fracture

    Directory of Open Access Journals (Sweden)

    Chad Correa

    2017-09-01

    Full Text Available History of present illness: A 77-year-old female presented to her primary care physician (PCP with right hip pain after a mechanical fall. She did not lose consciousness or have any other traumatic injuries. She was unable to ambulate post-fall, so X-rays were ordered by her PCP. Her X-rays were concerning for a right acetabular fracture (see purple arrows, so the patient was referred to the emergency department where a computed tomography (CT scan was ordered. Significant findings: The non-contrast CT images show a minimally displaced comminuted fracture of the right acetabulum involving the acetabular roof, medial and anterior walls (red arrows, with associated obturator muscle hematoma (blue oval. Discussion: Acetabular fractures are quite rare. There are 37 pelvic fractures per 100,000 people in the United States annually, and only 10% of these involve the acetabulum. They occur more frequently in the elderly totaling an estimated 4,000 per year. High-energy trauma is the primary cause of acetabular fractures in younger individuals and these fractures are commonly associated with other fractures and pelvic ring disruptions. Fractures secondary to moderate or minimal trauma are increasingly of concern in patients of advanced age.1 Classification of acetabular fractures can be challenging. However, the approach can be simplified by remembering the three basic types of acetabular fractures (column, transverse, and wall and their corresponding radiologic views. First, column fractures should be evaluated with coronally oriented CT images. This type of fracture demonstrates a coronal fracture line running caudad to craniad, essentially breaking the acetabulum into two halves: a front half and a back half. Secondly, transverse fractures should be evaluated by sagittally oriented CT images. By definition, a transverse fracture separates the acetabulum into superior and inferior halves with the fracture line extending from anterior to posterior

  19. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    OpenAIRE

    Hirokazu Takai, MD; Tomoki Takahashi, MD, PhD

    2017-01-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used ...

  20. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  1. Surgical treatment of isolated aseptic acetabular loosening of the hip joint

    Directory of Open Access Journals (Sweden)

    Zvereva К.Р.

    2017-09-01

    Full Text Available Aseptic acetabular loosening is one of the most common complications of primary hip arthroplasty Its treatment is possible in the volume of replacement of only the endoprosthesis cup with the preservation of a stable correctly oriented femoral component. The sequence of actions consists of provision of access to the acetabulum component and its replacement, after which the necessary offset is selected by changing the size of the head and installing a new pair of friction. Currently, the vast majority of the installed heads during the primary and revision hip replacement have a standard size forthe cone of the femoral component 12/14mm. According to the observations, in 3% of cases, there are femoral components with non-standard cone sizes 11/13 mm, usually established 7-8 years ago. The absence of heads forthe necessary cone leads to the need to replace the stable correctly oriented femoral component, which is accompanied by an increase in the time of intervention, the volume of intraoperative blood loss and the risk of intraopera-tive peri-prosthetic fracture. We represent the clinical case of a 75-year-old patient with a dislocation of the acetabular component and a stable correctly oriented femoral component, which during the audit intervention due to the lack of heads for an irregular cone size, total replacement of the components was made.

  2. Pelvic reconstructions following peri-acetabular bone tumour resections using a cementless ice-cream cone prosthesis with dual mobility cup.

    Science.gov (United States)

    Issa, Samir-Pierre; Biau, David; Babinet, Antoine; Dumaine, Valérie; Le Hanneur, Malo; Anract, Philippe

    2018-01-27

    Despite numerous reconstructive techniques and prosthetic devices, pelvic reconstructions following peri-acetabular malignant tumours resections are highly challenging. In the present study, we describe our experience with the Integra® (Lépine, Genay, France) ice-cream cone prosthesis in such indications. The objective was to assess the mid-term outcomes of this device. Twenty-four patients' chart with peri-acetabular malignant tumours, who underwent types II or II + III peri-acetabular resections according to Enneking and Dunham with subsequent reconstruction using the Integra® prosthesis between February 2009 and February 2015, were reviewed. Seventeen cases were primary surgeries and seven cases were revisions (i.e., failures of previous reconstructions for pelvic tumours). All living patients with the prosthesis implanted were functionally assessed, using the musculoskeletal tumour society (MSTS) and Postel-Merle d'Aubigné (PMA) scores. After a mean follow-up of 49 ± 26 months (range, 8 to 94 months), 21 patients were alive (88%), including 15 patients continuously disease-free (63%). MSTS and PMA scores averaged 72 ± 13% (range, 43 to 87%) and 14.6 ± 2.6 (range, 9 to 18), respectively. Fourteen patients (58%) presented at least one complication during follow-up, including four cases of deep infection (17%), four cases of dislocation (17%), and two mechanical failures (8%). At 5 years, the implant survival rate was 75%. In comparison to previous reconstructive techniques that we used in similar indications, functional and oncologic outcomes were improved with the Integra® implant. However, as commonly observed in pelvic bone tumour surgery, complication rates remain significant. Therapeutic, Level IV-Retrospective Cases Series.

  3. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  4. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    Science.gov (United States)

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1

  5. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  6. Acetabular fractures: what radiologists should know and how 3D CT can aid classification.

    Science.gov (United States)

    Scheinfeld, Meir H; Dym, Akiva A; Spektor, Michael; Avery, Laura L; Dym, R Joshua; Amanatullah, Derek F

    2015-01-01

    Correct recognition, description, and classification of acetabular fractures is essential for efficient patient triage and treatment. Acetabular fractures may result from high-energy trauma or low-energy trauma in the elderly. The most widely used acetabular fracture classification system among radiologists and orthopedic surgeons is the system of Judet and Letournel, which includes five elementary (or elemental) and five associated fractures. The elementary fractures are anterior wall, posterior wall, anterior column, posterior column, and transverse. The associated fractures are all combinations or partial combinations of the elementary fractures and include transverse with posterior wall, T-shaped, associated both column, anterior column or wall with posterior hemitransverse, and posterior column with posterior wall. The most unique fracture is the associated both column fracture, which completely dissociates the acetabular articular surface from the sciatic buttress. Accurate categorization of acetabular fractures is challenging because of the complex three-dimensional (3D) anatomy of the pelvis, the rarity of certain acetabular fracture variants, and confusing nomenclature. Comparing a 3D image of the fractured acetabulum with a standard diagram containing the 10 Judet and Letournel categories of acetabular fracture and using a flowchart algorithm are effective ways of arriving at the correct fracture classification. Online supplemental material is available for this article. (©)RSNA, 2015.

  7. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip.

    Science.gov (United States)

    Zhang, Yuan Z; Chen, Bin; Lu, Sheng; Yang, Yong; Zhao, Jian M; Liu, Rui; Li, Yan B; Pei, Guo X

    2011-12-01

    The considerable variation in anatomical abnormalities of hip joints associated with different types of developmental dysplasia of hip (DDH) makes reconstruction in total hip arthroplasty (THA) difficult. It is desirable to create patient-specific designs for THA procedures. In the cases of adult single DDH, an accuracy-improved method has been developed for acetabular cup prosthesis implantation of hip arthroplasty. From October 2007 to November 2008, 22 patients with single DDH (according to the Crowe standard, all dysplasia hips were classified as type I) were scanned with spiral CT pre-operatively. These patients scheduled for THA were randomly assigned to undergo either conventional THA (control group, n = 11) or navigation template implantation (NT group, n = 11). In the NT group, three-dimensional (3D) CT pelvis image data were transferred to a computer workstation and 3D models of the hip were reconstructed using the Mimics software. The 3D models were then processed by the Imageware software. In brief, a template that best fitted the location and shape of the acetabular cup was 'reversely' built from the 3D model, the rotation centre of the pathological hip determined by mirroring that of the healthy site, and a guiding hole in the template was then designed. The navigational templates were manufactured using a rapid prototyping machine. These navigation templates guide acetabular component placement. Based on the predetermined abduction angle 45° and anteversion angle 18°, after 1 year follow-up, the NT group showed significantly smaller differences (1.6° ± 0.4°, 1.9° ± 1.1°) from the predetermined angles than those in the control group (5.8° ± 2.9°, 3.9° ± 2.5°) (P < 0.05). The template designs facilitated accurate placement of acetabular components in dysplasia of acetabulum. The hip's center of rotation in DDH could be established using computer-aided design, which provides a useful method for the accurate

  8. Efficacy of a Pelvic Lateral Positioner With a Mechanical Cup Navigator Based on the Anatomical Pelvic Plane in Total Hip Arthroplasty.

    Science.gov (United States)

    Iwakiri, Kentaro; Kobayashi, Akio; Ohta, Yoichi; Minoda, Yukihide; Takaoka, Kunio; Nakamura, Hiroaki

    2017-12-01

    The acetabular component orientation in total hip arthroplasty (THA) is of critical importance to the good clinical results. However, traditional widely used cup alignment guides for cup placement are reported to be relatively unreliable. The present study aims at comparing a novel cup alignment guide, which can be attached to our anatomical pelvic plane (APP) pelvic lateral positioner for reducing discrepancies in sagittal pelvic tilt and indicate a targeted cup angle based on the APP, with a conventional cup alignment guide. The subjects were 136 hips of 136 patients who underwent unilateral THA using the APP positioner. The procedure was performed with the conventional cup alignment guide (conventional group; 60 hips) and with the novel cup navigator (mechanical navigator group; 76 hips). Postoperative cup angles and discrepancies of postoperative cup angles (inclination and anteversion angles) from the targeted angles were compared between the 2 groups to evaluate the usefulness of these navigators. The mean cup angles in the conventional group were 39.0° ± 5.3° for the inclination angle and 21.7° ± 6.4° for the anteversion angle, whereas those in the mechanical navigator group were 40.6° ± 3.2° and 18.3° ± 4.6°, respectively (P = .018, P cup navigator easily attachable to the APP positioner is a tool that can improve the accuracy of cup placement in a simple, economical, and noninvasive manner in THA via the lateral position. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Acetabular fractures: anatomic and clinical considerations.

    Science.gov (United States)

    Lawrence, David A; Menn, Kirsten; Baumgaertner, Michael; Haims, Andrew H

    2013-09-01

    Classifying acetabular fractures can be an intimidating topic. However, it is helpful to remember that there are only three basic types of acetabular fractures: column fractures, transverse fractures, and wall fractures. Within this framework, acetabular fractures are classified into two broad categories: elementary or associated fractures. We will review the osseous anatomy of the pelvis and provide systematic approaches for reviewing both radiographs and CT scans to effectively evaluate the acetabulum. Although acetabular fracture classification may seem intimidating, the descriptions and distinctions discussed and shown in this article hopefully make the topic simpler to understand. Approach the task by recalling that there are only three basic types of acetabular fractures: column fractures (coronally oriented on CT images), transverse fractures (sagittally oriented on CT images), and wall fractures (obliquely oriented on CT images). We have provided systematic approaches for reviewing both conventional radiographs and CT scans to effectively assess the acetabulum. The clinical implications of the different fracture patterns have also been reviewed because it is critically important to include pertinent information for our clinical colleagues to provide the most efficient and timely clinical care.

  10. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  11. Copas de metal trabecular y aloinjertos óseos impactados en defectos acetabulares graves. Resultados a los 2-4 años. [Impacted bone allografts and trabecular metal cups in severe acetabular bone defects: 2 to 4-year results.

    Directory of Open Access Journals (Sweden)

    Martín Buttaro

    2014-06-01

    Full Text Available In­tro­duc­ción: El objetivo principal es presentar la supervivencia del componente acetabular en pacientes con defectos graves reconstruidos con copas de metal trabecular combinadas con aloinjertos óseos impactados. Como objetivo secundario, se compararon estos resultados con los previamente obtenidos por los autores en defectos de similar gravedad utilizando anillos de reconstrucción y aloinjertos óseos. Materiales­ y­ Métodos:­ Se realizaron 20 cirugías de revisión en 19 pacientes (edad promedio 65 años, controlados, de forma prospectiva, con defectos acetabulares graves tipos 3A o 3B de Paprosky, por falla mecánica o infecciosa. El puntaje funcional promedio preoperatorio fue de 6,2 puntos, según la escala de Merle D ́Aubigne. Siempre se utilizaron copas de metal trabecular y aloinjertos óseos impactados. Resultados:­ A los 30 meses de seguimiento promedio (rango 24-48 meses, la supervivencia del componente acetabular fue del 95% (IC = 75%-98%. Un paciente presentó un aflojamiento acetabular por infección profunda a las 16 semanas de la revisión y fue tratado con una artroplastia de resección. El puntaje funcional promedio, excluido el caso con aflojamiento posoperatorio, fue de 16,2 puntos. Se observó la incorporación de los aloinjertos óseos en todos los pacientes, salvo el caso con infección profunda. La comparación con nuestras series históricas reconstruidas con anillos de Kerboull o con anillos GAP arrojó resultados altamente favorables a favor de las copas de metal trabecular.  Conclusiones: Las copas de metal trabecular asociadas a aloinjertos óseos impactados ofrecen una alternativa válida en cirugía de revisión acetabular con defectos graves del capital óseo. Este método se asocia a resultados más favorables que los obtenidos antes con anillos de reconstrucción.

  12. Cup-mixing type cup vending machines; Cup mixing shiki cup jido hanbaiki

    Energy Technology Data Exchange (ETDEWEB)

    Nishiwaki, S.; Nagasaki, T.; Hori, S. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1996-07-10

    This paper introduces the newly developed cup-mixing type cup vending machines. In the vending machines, the powder material for each beverage is stored, and the powder material delivered to a cup is carried to the cooking block by the carrier mechanism and cooked and mixed using a propeller mixer after hot and cold water are put. These vending machines meet the needs to the diversified and quality taste. The ejection port of products was also improved, and the door was designed to be higher in grade. The main block of structure is described next. The cup carrier mechanism consists of X, Y, and Z axes, and a hand. The cup is positioned by the control of a stepping motor. The number of propeller rotations in the propeller mechanism can be set to nine levels. The mixing position can also be set freely. In the temporary material reservation mechanism, the stored material is temporarily reserved until a cup is carried. The ejection port door of a cup is opened or closed automatically. The control block that drives the cup carrier mechanism is connected with the host unit by serial communication. 9 figs., 1 tab.

  13. CT of the acetabular fracture

    International Nuclear Information System (INIS)

    Magu, N.K.; Moda, S.K.; Magu, Sarita; Airon, R.K.

    1993-01-01

    Nine patients with 10 injured hips, in whom acetabular fractures with posterior dislocation of the femoral heads were demonstrated on initial radiography, underwent CT. CT was found superior in detecting the presence of intra-articular bony fragments in Group A patients (40%), where conventional radiography exhibited congruous manipulative reduction of the joint surfaces. The spatial position of the intra-articular fragments could not be ascertained on conventional radiography in 40% of the patients in Group B, in whom congruous manipulative reduction could not be achieved and subluxation of the femoral heads was observed. On conventional radiography, it was also difficult to appreciate the presence of intra-articular fragments in 60% of the patients in Group B, in whom either the dislocation could not be reduced (40%) or the femoral head redislocated after close manipulative reduction (20%). CT proved its superiority in detecting the extent of the fractures of the acetabular roof, posterior and anterior acetabular margins, the quadrilateral plate along with rotation of the acetabular columns and displacements of the major fractured fragments. Associated fractures of the sacrum (20%), and traumatic lesions of the sacro-iliac joint (20%), not apparent on conventional radiography were well demonstrated by CT. As a result of CT, the treatment was changed in 60% of the patients in Group A, and 40% in Group B. In addition, CT permitted a better choice of surgical technique in the management of acetabular fractures. (author). 9 refs., 3 figs., 2 tabs

  14. Total hip reconstruction in acetabular dysplasia : a finite element study

    NARCIS (Netherlands)

    Schüller, H.M.; Dalstra, M.; Huiskes, H.W.J.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  15. Press fit shape femoral heads for acetabular reconstruction - 5 to 8 years results

    International Nuclear Information System (INIS)

    Obenous, C.; Girtler, R.; Schwoger, W.; Winkler, H.

    1999-01-01

    Filling of acetabular defects with allograft bone is a favourable method in revision-THR provided that primary stability and load bearing capability can be achieved. Since 1990 we perform structural allografting in the acetabular area using a special technique. Defects are prepared with hemispherical reamers (male) in order to obtain a smooth concave surface. Deep-frozen femoral heads are then prepared using female shapers of a diameter 0-4mm larger, thus obtaining a convex surface fitting precisely into the prepared bed. In ideal cases a press-fit can be obtained granting primary stability without additional implants, otherwise we secure the grafts against rotation with one or two traction screws in loading-direction. Implantation of the cup is performed like in primary THR, care is taken to place the implant exactly at the anatomically correct position. Weight bearing is performed as soon as after primary THR; due to the technique loads are distributed evenly over the entire contact area to host bone, pressing the graft firmly into its bed. From 1990 to 1993 this method has been used in 179 cases. 104 cases could be followed between 60 and 95 months (average 71,5 months). Mean age at operation was 66,5 years (39-87 vears). Defects were classified according to Gross as cavitary in 15, minor column in 50 and major column in 39 cases. 85x the cup has been cemented, 19x cementless. One uncemented and 7 cemented cups loosened, all within the first 2 years. 6 meanwhile have been revised a second time. Those usually were cases, where the cup was placed in a non-anatomical position and / or the graft was not secured against rotatory forces. In 17 cases we observed slight condensation of the grafts with consequent migration of the implants. Migration usually did not exceed 5mm and no other signs of implant loosening have been associated. Radiographs indicated a unifon-n pattern of rapid graft-incorporation. Remodelling seemed to be completed after the second year, from

  16. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  17. CUSTOMIZED ACETABULAR COMPONENTS IN REVISION HIP ARTHROPLASTY

    Directory of Open Access Journals (Sweden)

    G. M. Kavalersky

    2016-01-01

    Full Text Available In recent years, there is a trend of increasing demand for revision hip arthroplasty. Among these patients there are many with complex acetabular defects, including patients with pelvic discontinuity. To ensure stability for revised acetabular components in such cases becomes a challenging or unachievable task. Such defects give indications for printing customized tri-flange acetabular component. The authors analysed own experience of creating and applying custom made acetabular components in 3 patients with complex acetabular defects. Material and methods. Among the patients there were 2 women and 1 man. Average age was 60,3±19,4 years (38 to 78 years. Two patients had III B defects with pelvic discontinuity and one patient had III A defect by Paprosky classification. As the first step, the authors in collaboration with engineers printed a plaster full size pelvic 3D model, as the second step a customized tri-flange acetabular component was designed and printed. Harris Hip Score was evaluated preoperatively and 3 months postoperatively. Results. Average follow-up period was 5,3±2,5 months (3 to 8 months. The authors observed no cases of implant loosening, dislocation or deep periprosthetic infection. Average Harris Hip Score before surgery was 27,13 and after surgery – 74,1 indicating a significant improvement in 3 months postoperatively. Conclusion. Indications for use of individual acetabular components in reported patients correspond to indications formulated by Berasi et al. The authors obtained encouraging early follow-up outcomes that correspond to data of other authors. In one patient certain difficulties were reported due to insufficient pelvic distraction. Component’s flanges prevented achieving adequate pelvic distraction. Nevertheless, good primary stability was achieved. Modern software and 3D metal printers can significantly reduce the production cost of customized acetabular components. Application of this technology can be

  18. Outcomes of cup revision for ilio-psoas impingement after total hip arthroplasty: Retrospective study of 46 patients.

    Science.gov (United States)

    Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S

    2017-12-01

    Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier

  19. A variable suppressed aperture and Faraday cup system

    International Nuclear Information System (INIS)

    Price, H.G.; Charlesworth, T.R.

    1979-02-01

    The injection system of the NSF accelerator within the high voltage enclosure is illustrated. The optics calls for a waist close to the entrance of the 500 kV accelerator tube. This waist will be the initial diagnostic point on the injection path for determining ion source performance and transmission through the later system. This will be made by determining the beam current after a preliminary mass analysis by the 30 0 magnet. To provide this diagnostic and to enable a waist to be formed at this point, a variable aperture and Faraday cup system is required. The Faraday cup will measure the beam transmitted by the aperture. Maximisation of this beam by adjustment of the preceding optical elements will ensure the waist in the beam at that point. (author)

  20. A New Automated Way to Measure Polyethylene Wear in THA Using a High Resolution CT Scanner: Method and Analysis

    Directory of Open Access Journals (Sweden)

    Gerald Q. Maguire Jr.

    2014-01-01

    Full Text Available As the most advantageous total hip arthroplasty (THA operation is the first, timely replacement of only the liner is socially and economically important because the utilization of THA is increasing as younger and more active patients are receiving implants and they are living longer. Automatic algorithms were developed to infer liner wear by estimating the separation between the acetabular cup and femoral component head given a computed tomography (CT volume. Two series of CT volumes of a hip phantom were acquired with the femoral component head placed at 14 different positions relative to the acetabular cup. The mean and standard deviation (SD of the diameter of the acetabular cup and femoral component head, in addition to the range of error in the expected wear values and the repeatability of all the measurements, were calculated. The algorithms resulted in a mean (±SD for the diameter of the acetabular cup of 54.21 (±0.011 mm and for the femoral component head of 22.09 (±0.02 mm. The wear error was ±0.1 mm and the repeatability was 0.077 mm. This approach is applicable clinically as it utilizes readily available computed tomography imaging systems and requires only five minutes of human interaction.

  1. Three finned press-fit cup: Does its initial fixation strength provide an adequate stability? Clinical midterm results of 685 implants

    Directory of Open Access Journals (Sweden)

    Rocco Romeo

    2016-01-01

    Full Text Available Introduction: One of the major causes of loosening of cementless acetabular cup implants is insufficient initial stability. A technical proposal to decrease the risk of suboptimal first stability is a circumferential finned design of the cup. This design aims to improve periacetabular bone contact and prevent rotational micromotion of the cup when optimal press-fit cannot be obtained. Materials and Methods: We retrospectively reviewed a group of 712 consecutive patients who underwent total hip arthroplasty from June 2006 to June 2014. In all patients, a titanium cup, characterized by three anti-rotational circumferential fins at the superior pole, was implanted. Results: Five hundred and ninety-two patients, for a total of 685 hips, were evaluated at a mean follow-up of 58 months (range 12-96 months. At 1-year follow-up, the average score increased to 82.90 (range 100-70 and at the final follow-up (58 months, range 12-96 months, it was 80.12 (range 100-66. In 22 cases (3%, screws to obtain a secure primary stability of the cup were used. Nineteen complications (2.6% needing revision surgery were observed. Survivorship at 10 years was 98.7% (95% confidence interval [CI], 98.7-99.7% with revision for aseptic cup loosening as an endpoint and 96.7% (95% CI, 98.3-95.1% with revision for all causes of revision as the second endpoint. Discussion: In our group of patients, we did not observe the cases of very early cup loosening. The only two-cup revision, do to loosening of osteolysis, was observed 26 and 32 months before surgery. Conclusion: Our very low rate of additional screws represents an indirect sign of finned cup first stability. Three-finned cup design clinically confirmed to improve initial cup stability.

  2. Comparison of dual mobility cup and other surgical construts used for three hundred and sixty two first time hip revisions due to recurrent dislocations: five year results from Lithuanian arthroplasty register.

    Science.gov (United States)

    Stucinskas, Justinas; Kalvaitis, Tomas; Smailys, Alfredas; Robertsson, Otto; Tarasevicius, Sarunas

    2018-05-01

    Recently, there has been increasing interest in the use of dual mobility systems in the treatment of hip instability. The aim of this study was to investigate the re-revision rate of dual mobility cup compared to different surgical concepts when used for first-time hip revisions due to recurrent dislocations. The data were derived from the Lithuanian Arthroplasty Register. For survival analysis, we used both re-revision for all reasons and for dislocations as an end-point. Cox proportional hazards models were used to analyze the influence of various covariates (age, gender, and implant concept). A total of 1388 revisions were recorded from 2011 to 2015, of which 362 were performed due to recurrent dislocation. Of the revisions, 247 were performed using dual mobility cups, while 115 were performed using a variety of other surgical constructs including constrained acetabular cups, conventional cups, femoral head exchanges, stem exchanges or anti-luxation rings. There were 27 re-revisions of which 15 were for additional dislocations. There were only 2% re-revisions due to dislocation with dual mobility vs 9% when using other surgical constructs. Cox regression adjusting for age and gender showed that in the short-term, dual mobility cup had a lower risk of revision due to dislocation as well as for all reasons compared to the other surgical constructs. In revision of total hip arthroplasties for dislocation, significantly lower short-term re-revision rate was observed for patients revised with dual mobility cup.

  3. Three Year RSA Evaluation of Vitamin E Diffused Highly Cross-linked Polyethylene Liners and Cup Stability.

    Science.gov (United States)

    Sillesen, Nanna H; Greene, Meridith E; Nebergall, Audrey K; Nielsen, Poul T; Laursen, Mogens B; Troelsen, Anders; Malchau, Henrik

    2015-07-01

    Vitamin E diffusion into highly cross-linked polyethylene (E-XLPE) is a method for enhancing oxidative stability of acetabular liners. The purpose of this study was to evaluate in vivo penetration of E-XLPE using radiostereometric analysis (RSA). Eighty-four hips were recruited into a prospective 10-year RSA. This is the first evaluation of the multicenter cohort after 3-years. All patients received E-XLPE liners (E1, Biomet) and porous-titanium coated cups (Regenerex, Biomet). There was no difference (P=0.450) in median femoral head penetration into the E-XLPE liners at 3-years comparing cobalt-chrome heads (-0.028mm; inter-quartile range (IQR) - 0.065 to 0.047) with ceramic heads (-0.043mm, IQR - 0.143to0.042). The 3-year follow-up indicates minimal E-XLPE liner penetration regardless of head material and minimal early cup movement. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Transfer of metallic debris from the metal surface of an acetabular cup to artificial femoral heads by scraping: comparison between alumina and cobalt-chrome heads.

    Science.gov (United States)

    Chang, Chong Bum; Yoo, Jeong Joon; Song, Won Seok; Kim, Deug Joong; Koo, Kyung-Hoi; Kim, Hee Joong

    2008-04-01

    We aimed to investigate the transfer of metal to both ceramic (alumina) and metal (cobalt-chrome) heads that were scraped by a titanium alloy surface under different load conditions. The ceramic and metal heads for total hip arthroplasties were scraped by an acetabular metal shell under various loads using a creep tester. Microstructural changes in the scraped area were visualized with a scanning electron microscope, and chemical element changes were assessed using an energy dispersive X-ray spectrometry. Changes in the roughness of the scraped surface were evaluated by a three-dimensional surface profiling system. Metal transfer to the ceramic and metal heads began to be detectable at a 10 kg load, which could be exerted by one-handed force. The surface roughness values significantly increased with increasing test loads in both heads. When the contact force increased, scratching of the head surface occurred in addition to the transfer of metal. The results documented that metallic debris was transferred from the titanium alloy acetabular shell to both ceramic and metal heads by minor scraping. This study suggests that the greatest possible effort should be made to protect femoral heads, regardless of material, from contact with metallic surfaces during total hip arthroplasty.

  5. [Quantification of acetabular coverage in normal adult].

    Science.gov (United States)

    Lin, R M; Yang, C Y; Yu, C Y; Yang, C R; Chang, G L; Chou, Y L

    1991-03-01

    Quantification of acetabular coverage is important and can be expressed by superimposition of cartilage tracings on the maximum cross-sectional area of the femoral head. A practical Autolisp program on PC AutoCAD has been developed by us to quantify the acetabular coverage through numerical expression of the images of computed tomography. Thirty adults (60 hips) with normal center-edge angle and acetabular index in plain X ray were randomly selected for serial drops. These slices were prepared with a fixed coordination and in continuous sections of 5 mm in thickness. The contours of the cartilage of each section were digitized into a PC computer and processed by AutoCAD programs to quantify and characterize the acetabular coverage of normal and dysplastic adult hips. We found that a total coverage ratio of greater than 80%, an anterior coverage ratio of greater than 75% and a posterior coverage ratio of greater than 80% can be categorized in a normal group. Polar edge distance is a good indicator for the evaluation of preoperative and postoperative coverage conditions. For standardization and evaluation of acetabular coverage, the most suitable parameters are the total coverage ratio, anterior coverage ratio, posterior coverage ratio and polar edge distance. However, medial coverage and lateral coverage ratios are indispensable in cases of dysplastic hip because variations between them are so great that acetabuloplasty may be impossible. This program can also be used to classify precisely the type of dysplastic hip.

  6. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  7. Three-dimensional magnetic resonance imaging analysis of hip morphology in the assessment of femoral acetabular impingement

    International Nuclear Information System (INIS)

    Kavanagh, E.C.; Read, P.; Carty, F.; Zoga, A.C.; Parvizi, J.; Morrison, W.B.

    2011-01-01

    Aim: To determine a possible association between femoral-acetabular impingement (FAI) volume and the development of labral tear using a three-dimensional (3D) model reconstruction of the acetabulum and the femoral head. Materials and methods: Magnetic resonance arthrography images of the hip in 42 patients with pain and suspected labral tear were acquired using a 1.5 T MRI machine. Using 3D analysis software, outlines of the acetabular cup and femoral head were drawn and 3D reconstruction obtained. To control for differences in patient size, ratios of acetabulum : femoral head volume (AFV) and acetabulum : femoral head surface area (AFA) were used for analysis. The association between volume of acetabulum : femoral head and FAI was investigated using ANOVA analysis. Results: There were 19 men and 23 women with a mean age of 39 years (range 18-78 years). The average AFV was 0.64 (range 0.37-1.05, SD 0.16) and AFA was 0.73 (range 0.36-1.26, SD 0.23). Herniation pit was significantly associated with a small AFV. Conclusion: Femoral neck herniation pits are associated with a low AFV. Gross volume and surface area ratios do not appear to correlate with labral tears or cartilage loss. This technique will enable more advanced analysis of morphological variations associated with FAI.

  8. Accelerated aging, natural aging, and small punch testing of gamma-air sterilized polycarbonate urethane acetabular components.

    Science.gov (United States)

    Kurtz, S M; Siskey, R; Reitman, M

    2010-05-01

    The objectives of this study were three-fold: (1) to determine the applicability of the small punch test to characterize Bionate 80A polycarbonate urethane (PCU) acetabular implants; (2) to evaluate the susceptibility of PCU acetabular implants to exhibit degradation of mechanical behavior following gamma irradiation in air and accelerated aging; and (3) to compare the oxidation of gamma-air sterilized PCU following accelerated aging and 5 years of natural shelf aging. In addition to attenuated total reflectance-Fourier transform infrared spectroscopy, we also adapted a miniature specimen mechanical test, the small punch test, for the deformable PCU cups. Accelerated aging was performed using ASTM F2003, a standard test that represents a severe oxidative challenge. The results of this study suggest that the small punch test is sufficiently sensitive and reproducible to discriminate slight differences in the large-deformation mechanical behavior of Bionate 80A following accelerated aging. The gamma-air sterilized PCU had a reduction of 9% in ultimate load after aging. Five years of shelf aging had little effect on the mechanical properties of the PCU. Overall, our findings suggest that the Bionate 80A material has greater oxidative stability than ultra-high molecular weight polyethylene following gamma irradiation in air and exposure to a severe oxidative challenge. (c) 2010 Wiley Periodicals, Inc.

  9. MR imaging findings of acetabular dysplasia in adults

    Energy Technology Data Exchange (ETDEWEB)

    James, Steven; Connell, David [The Royal National Orthopaedic Hospital, Radiology Department, London, Middlesex (United Kingdom); Miocevic, Miranda; Malara, Frank; Pike, Jonathan [Victoria House Hospital, Radiology Department, Melbourne (Australia); Young, David [Melbourne Orthopaedic Group, Orthopaedic Surgery, Melbourne (Australia)

    2006-06-15

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  10. MR imaging findings of acetabular dysplasia in adults

    International Nuclear Information System (INIS)

    James, Steven; Connell, David; Miocevic, Miranda; Malara, Frank; Pike, Jonathan; Young, David

    2006-01-01

    To evaluate the diagnostic accuracy of MR imaging in the identification of labral and articular cartilage lesions in patients with acetabular dysplasia. Pre-operative MR imaging was performed on 27 hips in 25 consecutive patients (16 males, 9 females, age range 19-52 years, mean age 31.2 years) with radiographic evidence of acetabular dysplasia (centre-edge angle of Wiberg <20 degrees). The average duration of symptoms was 16.2 months. Two musculoskeletal radiologists assessed MR images in consensus for the presence of abnormality involving the acetabular labrum and adjacent acetabular articular cartilage. A high resolution, non-arthrographic technique was used to assess the labrum and labral chondral transitional zone. Surgical correlation was obtained in all cases by a single surgeon experienced in hip arthroscopy and ten patients with normal hip MRI were included to provide a control group. The acetabular labra in the dysplastic hips demonstrated abnormal signal intensity, and had an elongated appearance when compared with the control group (mean length 10.9 mm vs 6.4 mm). Morphological appearances in the labra included surface irregularity, fissures and cleft formation. MR imaging correctly identified the severity of chondral abnormality in 24 of 27 hips (89%) when compared with arthroscopic findings. MR imaging demonstrates an elongated labrum, focal intra-substance signal change and irregularity and fissuring of the margins in patients with acetabular dysplasia. Abnormality is also identified at the labral chondral transitional zone, where fissuring, focal clefts, chondral deficiency and subchondral cyst formation may be apparent. A high-resolution, non-arthrographic technique can provide an accurate preoperative assessment and evaluate the presence of premature osteoarthritis. (orig.)

  11. Image research on acetabular teardrop shadow by X-ray plain-film and CT

    International Nuclear Information System (INIS)

    Wang Xiaoxuan; Zhai Yuejie; Yu Hongguang; Yang Yijun; Zhang Daiwei; Chen Aili; Song Quanjun

    2001-01-01

    Objective: To evaluate the anatomical structure of bone in the formation of acetabular teardrop shadow. Methods: The acetabular teardrop shadow of the X-ray plain-film in 100 children and 300 adults, and of CT in 43 cases were analysed, measured and compared. Results: In children, teardrop shadow appeared 'U' in 80.00%, 14.00% in teardrop, 6.00% in line. In adult teardrop shadow appeared 'U' in 41.33%, 53.33% in teardrop, 5.34% in line. There were significant differences between children and adult in the frequency of 'U' and teardrop (x 2 = 43.34, P 2 = 45.62, P < 0.01). In children, inpeduncle of teardrop shadow was formed of middle 1/3 substantia-line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 substantia-line of bottom of acetabular. In adult, inpeduncle was formed of middle 1/3 or back 1/3 substantia line of acetabular concavity inside of pelvis; outpeduncle was formed of middle 1/3 or back 1/3 substantia-line of bottom of acetabular. Conclusion: In children, acetabular teardrop shadow was mainly formed of middle 1/3 bone of acetabular concavity. In adult, middle 1/3 or back 1/3 bone of acetabular concavity contribute to the shadow. The ahead 1/3 bone of acetabular concavity is not involved

  12. Outcomes and prognostic factors in revision hip arthroplasty for severe intra-pelvic cup protrusion: 246 cases.

    Science.gov (United States)

    Epinette, J-A; Mertl, P; Combourieu, B; Goncalves, H; Blairon, A; Ehlinger, M; Tabutin, J

    2015-10-01

    The outcome of revision total hip arthroplasty (THA) for intra-pelvic cup protrusion is unclear. Hence, we conducted a large retrospective study to clarify the surgical strategy (hip lever arm and cup mechanical fixation) and the outcomes of reconstruction for severe intra-pelvic cup protrusion. We hypothesized that restoration of the anatomic hip centre in such acetabular revisions decreased the risk of recurrent loosening. The study included 246 THA procedures (in 220 patients), with a follow-up of 5.2 ± 4.9 years (1-24.2) after the index surgery. Bone loss was estimated using the SOFCOT classification (grade III or IV in 80% of cases) and the Paprosky classification (IIIA or IIIB in 58% of cases). Quality of the reconstruction was assessed on X-rays according to the correction of the protrusion and position of the hip centre of rotation. After a clinical follow-up of at least 5 years, with a mean of 9.9 ± 4.1 years (5-24 years), the mean Postel-Merle d'Aubigné score was 14.2 ± 3.1 and the mean Harris Hip Score was 78.0 ± 18.7. Cup protrusion was partially or completely corrected in every case and cup position was normal in 27 (11%) cases. The centre of rotation was within 10mm of the physiological position in 158 (64.2%) cases, acceptable in 77 (31.3%) cases, ascended in 9 (3.7%) cases, and worsened in 1 (0.4%) case. Revision for cup or cup and femoral failures was required in 24 (9.8%) cases. Cumulative survival rates with cup loosening as the endpoint were 88.5% after 5 years, 79.9% after 10 years, and 63.9% at last follow-up at 13.6 years. Our hypothesis that restoration of anatomic hip centre decreased the risk of recurrent loosening was not verified: success or failure in restoring the normal centre of rotation did not correlate significantly with final cup status. Recurrent aseptic loosening was the cause of failure in 9.8% of cases. Ensuring long-term effective mechanical stability had a greater impact on global outcomes than restoring an ideal

  13. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  14. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  15. Single-stage Acetabular Revision During Two-stage THA Revision for Infection is Effective in Selected Patients.

    Science.gov (United States)

    Fink, Bernd; Schlumberger, Michael; Oremek, Damian

    2017-08-01

    The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All

  16. Surgical Stabilization of Pelvic and Acetabular Fractures: A Review on the Determinants of Clinical Outcomes

    Directory of Open Access Journals (Sweden)

    SS Sathappan

    2010-03-01

    Full Text Available AIM: Pelvic and acetabular fractures are associated with high-energy trauma. The aim of this study was to identify factors that are associated with specific clinical outcomes following treatment for these fractures. METHODS: A consecutive series of 30 patients who had surgical intervention for either pelvic or acetabular fractures formed the sample for this study. Clinical variables reviewed were: age, associated injuries, number of surgical procedures, time to surgery and post-operative complications. Clinical outcomes were assessed using Matta’s grading of post- operative fracture reduction alignment, and functional outcomes were graded using D'Aubigne & Postel’s Hip scoring system. RESULTS: Study subjects included twelve pelvic fractures and eighteen acetabular fractures. Patients older than 50 years of age had poorer hip scores despite surgery. Earlier fracture fixation (within five days was associated with better hip scores. Patients with acetabular fractures generally had better functional outcomes than patients with pelvic fractures (mean hip score 15.0 vs. 13.5. Closer anatomical reduction of acetabular fractures was associated with better functional outcome. CONCLUSION: Improved clinical outcomes are associated with younger age, fewer concomitant injuries, shorter time interval to surgery and more closely approximated anatomical fracture reduction.

  17. Acetabular labral tears in patients with sports injury.

    Science.gov (United States)

    Kang, Chan; Hwang, Deuk-Soo; Cha, Soo-Min

    2009-12-01

    We wanted to investigate acetabular labral tears and their correlation with femoroacetabular impingement in patients with sports injury. Among 111 patients who were diagnosed with the acetabular labral tears after arthroscopic treatment from January 2004 to December 2007, we selected 41 patients with sports injury. There were 12 cases of Taekwondo injury, 5 of golf injury, 4 of soccer injury, 3 of gymnastics injury, 2 of Hapkido injury, 2 of aerobics injury, 2 of rock-climbing injury, 2 of fitness training injury and 9 of other sports injuries. We checked the subtypes of acetabular labral tears and the accompanying femoroacetabular impingement. For the cases with accompanying femoroacetabular impingement, we investigated the subtypes according to the types of sports, gender and age. At last follow-up, we checked the Harris Hip Score (HHS), the Hip Outcome Score (HOS) sports scale and the percentage of patients who returned to their sports activity. The average age of symptomatic onset was 26 years (range, 12 to 65 years). The ratio of males to females was 29 : 12. An average duration of the hip pain was 17 months (range, 1 to 60 months). The degenerative type of acetabular labral tears was the most prevalent with 32 cases (78%), and there were 9 cases (22%) of the partial tear type. Thirty cases (73%) were accompanied by femoroacetabular impingement. The average age of the 23 cases (56%) of the cam-type was 23 years (range, 12 to 48 years), and it was more likely to occur in men (87%) and for people practicing martial arts such as Taekwondo or Hapkido. An average age of the 5 cases (12%) of the pincer-type was 26 (range, 16 to 43 years), it usually occurred in women (60%) and for non-martial arts such as golf and gymnastics. There were 2 cases of the mixed type (cam + pincer-type). At 27 months follow-up, the HHS was 61 to 92 points, the HOS sports scale increased 43 to 75%, and the rate of returning to sports was 71%. In spite of the early expression of symptoms

  18. Plain film analysis of acetabular fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik Hospital, Pusan (Korea, Republic of)

    1986-02-15

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%)

  19. Plain film analysis of acetabular fracture

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1986-01-01

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%).

  20. Posterior trochanteric osteotomy in acetabular fractures for 32 cases.

    Science.gov (United States)

    Niu, Yunfei; An, Xiaofei; Xu, Shuogui; Wu, Dajiang; Zhang, Chuncai; Li, Ming

    2014-11-01

    The aim of this study is to explore the method and clinical outcome of posterior trochanteric osteotomy in acetabular fractures. From January 2000 to January 2008, 32 cases of acetabular fractures involving the dome of acetabulum underwent posterior trochanteric osteotomy for a better exposure and internal fixation with acetabular tridimensional memory fixation system. 28 cases (16 men and 12 women, mean age 39.9 years, range 16-73 years) were followed up with an average of 48.9 months (range of 19-95 months) and four were lost during follow up. Of 28 cases, 19 were fresh fractures and 9 were old fractures. The reduction was evaluated with Matta criteria. Clinical evaluation was based on modified Merle d'Aubigne and Postel scoring. Motor strength of the abductors was evaluated according to the Medical Research Council grading system. Ectopic ossification was classified according to Brooker criteria. Anatomical reduction was achieved in 17 cases and satisfied reduction in 10 patients. Poor reduction happened in an old fracture. All acetabular fractures got a direct bone union and no displacement and deep infection occurred. All osteotomies healed within 3.5 months without any nonunion, proximal migration of the greater trochanter, loosing or broken of instrumentation, and deep infection. Two superficial infections were healed with a regular dressing. Two patients underwent removal of implants from greater trochanter because of irritation. The strength of the abductors was of Grade 3/5 in two patients, Grade 4/5 in five patients, and normal in the rest. Clinical scoring was excellent to good in 84 %. Ectopic ossification occurred in five patients, grade 1 in two patients, grade 2 in two, and grade 3 in one. But function of hip joint was not seriously affected. Posterior trochanteric osteotomy can provide an adequate exposure of the dome of acetabulum without the associated complications like nonunion, proximal replacement, and weak of the abductors which often occur

  1. [Tripolar cups].

    Science.gov (United States)

    Fink, B

    2015-04-01

    Tripolar cups can be separated into constrained and unconstrained dual-mobility cups. The latter show better survival and revision rates. The main problem is the polyethylene wear. Therefore modern types of polyethylene are used in these cups. The indications for dual-mobility cups are recurrent dislocation and situations where the risk of dislocation is increased. Georg Thieme Verlag KG Stuttgart · New York.

  2. The nerve endings of the acetabular labrum.

    Science.gov (United States)

    Kim, Y T; Azuma, H

    1995-11-01

    The nerve endings of the human acetabular labrum were investigated. Twenty-three acetabular labra were obtained from 24 fresh human cadavers, stained with Suzuki's silver impregnation and an immunohistochemical technique for neurogenic specific protein S-100, and examined by light and electron microscopy. Ramified free nerve endings were seen in all specimens by silver staining, and also were observed by the immunohistochemical technique for S-100 protein. Sensory nerve end organs, such as a Vater-Pacini corpuscle, Golgi-Mazzoni corpuscle, Ruffini corpuscle, and articular corpuscle (Krause corpuscle), were observed by silver staining. Collagen fibers were scattered sparsely in the superficial layer of the labrum, and nerve endings were observed mostly in this region. Collagen fibers were sparse, and nerve endings also were observed in some regions among the collagen fiber bundles in the inner layer. Innervation of the acetabular labrum was confirmed in this study, suggesting that nerve endings in the labrum may be involved in nociceptive and proprioceptive mechanisms.

  3. Assessment of trochanteric osteotomy fragment union after acetabular fracture surgery.

    Science.gov (United States)

    Dubina, Andrew G; Wickramaratne, Niluka; O'Toole, Robert V; Manson, Theodore T

    2017-02-01

    Trochanteric osteotomies are performed in conjunction with standard approaches to improve surgical exposure during open reduction and internal fixation (ORIF) of acetabular fractures. The literature on total hip arthroplasty reports nonunion rates as high as 30% associated with trochanteric osteotomies; however, few data exist regarding the outcomes of trochanteric osteotomies for acetabular fracture surgery. Our hypotheses were 1) patients receiving trochanteric osteotomies during ORIF of acetabular fractures have a low rate of nonunion of the osteotomy fragment, and 2) hip abduction precautions are not necessary with digastric type osteotomies. A retrospective review was conducted to identify patients with acetabular fractures between July 2002 and June 2010 (n=734 fractures) who required trochanteric osteotomies (n=64, 9% of fractures). Forty-seven met inclusion criteria of adequate follow-up (>56days). No excluded patient experienced a complication. Fractures were classified using the Letournel-Judet classification system. Only seven (20%) of 35 patients who received digastric osteotomies had hip abduction precautions applied during the postoperative period. All study patients were shown to have radiographic union at the trochanteric osteotomy site (100% union rate, n=47). Hip abduction precautions intended to protect the osteotomy site and reduce the risk of nonunion and fixation failure were infrequently applied to patients with digastric osteotomies (20%) in this cohort. Multiple protective factors against nonunion were present in this study population compared with previous arthroplasty studies from other institutions. Trochanteric osteotomies are not associated with a significant nonunion rate, and digastric osteotomies might be safely managed without hip abduction precautions. Copyright © 2016. Published by Elsevier Ltd.

  4. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD).

    Science.gov (United States)

    Nitschke, Ashley; Lambert, Jeffery R; Glueck, Deborah H; Jesse, Mary Kristen; Mei-Dan, Omer; Strickland, Colin; Petersen, Brian

    2015-11-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p TAD (p TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain.

  5. Acetabular paralabral cyst causing compression of the sciatic nerve

    Directory of Open Access Journals (Sweden)

    Caoimhe Byrne, MB BCh BAO

    2017-12-01

    Full Text Available Acetabular paralabral cysts are common. They vary in their clinical presentation and may be asymptomatic or cause pain and restriction at the hip joint. In rare instances they may cause symptoms by compressing local neurovascular structures. We report a case of symptomatic compression of the sciatic nerve by a posteriorly displaced acetabular paralabral cyst.

  6. Proteomic effects of wet cupping (Al-hijamah).

    Science.gov (United States)

    Almaiman, Amer A

    2018-01-01

    Wet cupping (Al-hijamah) is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient's skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted.

  7. Proteomic effects of wet cupping (Al-hijamah

    Directory of Open Access Journals (Sweden)

    Amer A. Almaiman

    2018-01-01

    Full Text Available Wet cupping (Al-hijamah is a therapeutic technique practiced worldwide as a part of the Unani system of medicine. It involves bloodletting from acupoints on a patient’s skin to produce a therapeutic outcome. A thorough review of research articles on wet cupping with relevance to proteomics field that are indexed by Google Scholar, PubMed, and/or Science Direct databases was performed. Eight original research articles were summarized in this paper. Overall, wet cupping did not have a significant effect on C-reactive protein, Hsp-27, sister chromatid exchanges, and cell replication index. In contrast, wet cupping was found to produce higher oxygen saturation, eliminate lactate from subcutaneous tissues, remove blood containing higher levels of malondialdehyde and nitric oxide, and produce higher activity of myeloperoxidase. The proteomic effects of wet cupping therapy have not been adequately investigated. Thus, future studies on wet cupping that use systemic and sound protocols to avoid bias should be conducted.

  8. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    Energy Technology Data Exchange (ETDEWEB)

    Nitschke, Ashley [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology, Aurora, CO (United States); Lambert, Jeffery R. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); Glueck, Deborah H. [University of Colorado, Department of Biostatistics and Informatics, Colorado School of Public Health, Aurora, CO (United States); University of Colorado School of Medicine, University of Colorado Denver, Department of Radiology, Aurora, CO (United States); Jesse, Mary Kristen; Strickland, Colin [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Mei-Dan, Omer [University of Colorado School of Medicine, University of Colorado Denver, Division of Sports Medicine and Hip Preservation, Department of Orthopaedics, Aurora, CO (United States); Petersen, Brian [University of Colorado School of Medicine, University of Colorado Denver, Division of Musculoskeletal Radiology, Department of Radiology and Orthopaedics, Aurora, CO (United States); Inland Imaging, Division of Musculoskeletal Radiology, Spokane, WA (United States)

    2015-11-15

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  9. Validation of a new radiographic measurement of acetabular version: the transverse axis distance (TAD)

    International Nuclear Information System (INIS)

    Nitschke, Ashley; Lambert, Jeffery R.; Glueck, Deborah H.; Jesse, Mary Kristen; Strickland, Colin; Mei-Dan, Omer; Petersen, Brian

    2015-01-01

    This study has three aims: (1) validate a new radiographic measure of acetabular version, the transverse axis distance (TAD) by showing equivalent TAD accuracy in predicting CT equatorial acetabular version when compared to a previously validated, but more cumbersome, radiographic measure, the p/a ratio; (2) establish predictive equations of CT acetabular version from TAD; (3) calculate a sensitive and specific cut point for predicting excessive CT acetabular anteversion using TAD. A 14-month retrospective review was performed of patients who had undergone a dedicated MSK CT pelvis study and who also had a technically adequate AP pelvis radiograph. Two trained observers measured the radiographic p/a ratio, TAD, and CT acetabular equatorial version for 110 hips on a PACS workstation. Mixed model analysis was used to find prediction equations, and ROC analysis was used to evaluate the diagnostic accuracy of p/a ratio and TAD. CT equatorial acetabular version can accurately be predicted from either p/a ratio (p < 0.001) or TAD (p < 0.001). The diagnostic accuracies of p/a ratio and TAD are comparable (p =0.46). Patients whose TAD is higher than 17 mm may have excessive acetabular anteversion. For that cutpoint, the sensitivity of TAD is 0.73, with specificity of 0.82. TAD is an accurate radiographic predictor of CT acetabular anteversion and provides an easy-to-use and intuitive point-of-care assessment of acetabular version in patients with hip pain. (orig.)

  10. Acetabular paralabral cyst: an uncommon cause of sciatica

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, P.M.; Sanders, T.G. [Department of Radiology, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States); Matchette, M.W. [University of Texas Medical School, 7703 Floyd Curl Drive, San Antonio, TX 78229-3900 (United States); Parsons, T.W. [Department of Orthopedic Surgery, Wilford Hall Medical Center, 2200 Bergquist Drive, Ste. 1, Lackland AFB, TX 78236 (United States)

    2003-02-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  11. Acetabular paralabral cyst: an uncommon cause of sciatica

    International Nuclear Information System (INIS)

    Sherman, P.M.; Sanders, T.G.; Matchette, M.W.; Parsons, T.W.

    2003-01-01

    The association between tears of the acetabular labrum and paralabral cysts has been well documented, and magnetic resonance imaging (MRI) has been shown to be the most accurate noninvasive method of depicting not only the normal anatomic structures of the hip, but also the common pathologic processes such as labral tears and paralabral cysts. We present the case of an acetabular paralabral cyst that resulted in clinically symptomatic compression of the sciatic nerve. (orig.)

  12. CUSTOM TRIFLANGE ACETABULAR COMPONENTS IN REVISION HIP REPLACEMENT (EXPERIENCE REVIEW

    Directory of Open Access Journals (Sweden)

    A. A. Korytkin

    2017-01-01

    Full Text Available Extensive defects of acetabulum especially accompanied by pelvis discontinuity at the level of acetabulum pose a serious challenge in revision hip replacement and create additional complexity in fixing the acetabular component. One of the perspective options to solve the above issue is the use of custom triflange acetabular components (CTAC designed based on preoperative computer tomography given the specifics of bone defects of the patient. Purpose of the study — to evaluate the outcomes of CTAC use in revision hip replacement.Materials and methods. The authors analyzed treatment outcomes of 12 patients after revision hip replacement using additive techniques of computer simulation and 3D printing CTAC. Follow up period after the surgery averaged 7±3 months (from one to ten months. 7 out of 12 patients had acetabular defects of Paprosky 3B type, 4 patients had defects of Paprosky 3A and in one patient — of Paprosky 2C.Results. Two out of twelve patients had prosthesis dislocations that required revision hip surgery, one of those patients underwent open reduction of dislocation with wound debridement, another patient underwent replacement of articulating couple of acetabular component. Total scores under Harris Hip Score and paint VAS score prior to treatment was 28±7 and 7±1 points respectively, postoperative scores were 76±9 and 3±1 respectively.Conclusion. The application of additive techniques for revision hip replacement in patients with extensive acetabular and pelvic defects allows to make a precise preoperative planning, to restore joint rotation center, to reconstruct bone defects and to securely fix triflange acetabular component that altogether significantly improve treatment outcomes and patients satisfaction with the surgery.

  13. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro [Asahikawa Medical College, Department of Orthopaedic Surgery, Asahikawa (Japan); Minami, Akio [Hokkaido University School of Medicine, Department of Orthopaedic Surgery, Sapporo (Japan)

    2009-02-15

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  14. Three-dimensional computed tomography analysis of non-osteoarthritic adult acetabular dysplasia

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Matsuno, Takeo; Hirayama, Teruhisa; Tanino, Hiromasa; Yamanaka, Yasuhiro; Minami, Akio

    2009-01-01

    Little data exists on the original morphology of acetabular dysplasia obtained from patients without radiographic advanced osteoarthritic changes. The aim of this study was to investigate the distribution and degree of acetabular dysplasia in a large number of patients showing no advanced degenerative changes using three-dimensional computed tomography (3DCT). Eighty-four dysplastic hips in 55 consecutive patients were studied. All 84 hips were in pre- or early osteoarthritis without radiographic evidence of joint space narrowing, formation of osteophytes or cysts, or deformity of femoral heads. The mean age at the time of CT scan was 35 years (range 15-64 years). 3D images were reconstructed and analyzed using recent computer imaging software (INTAGE Realia and Volume Player). Deficiency types and degrees of acetabular dysplasia were precisely evaluated using these computer software. The average Harris hip score at CT scans was 82 points. Twenty-two hips (26%) were classified as anterior deficiency, 17 hips (20%) as posterior deficiency, and 45 hips (54%) as lateral deficiency. No significant difference was found in the Harris hip score among these groups. The analysis of various measurements indicated wide variations. There was a significant correlation between the Harris hip score and the acetabular coverage (p < 0.001). Our results indicated wide variety of deficiency type and degree of acetabular dysplasia. Hips with greater acetabular coverage tended to have a higher Harris hip score. (orig.)

  15. Wet cupping therapy restores sympathovagal imbalances in cardiac rhythm.

    Science.gov (United States)

    Arslan, Müzeyyen; Yeşilçam, Nesibe; Aydin, Duygu; Yüksel, Ramazan; Dane, Senol

    2014-04-01

    A recent study showed that cupping had therapeutic effects in rats with myocardial infarction and cardiac arrhythmias. The current studyaimed to investigate the possible useful effects of cupping therapy on cardiac rhythm in terms of heart rate variability (HRV). Forty healthy participants were included. Classic wet cupping therapy was applied on five points of the back. Recording electrocardiography (to determine HRV) was applied 1 hour before and 1 hour after cupping therapy. All HRV parameters increased after cupping therapy compared with before cupping therapy in healthy persons. These results indicate for the first time in humans that cupping might be cardioprotective. In this study, cupping therapy restored sympathovagal imbalances by stimulating the peripheral nervous system.

  16. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  17. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    Science.gov (United States)

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides

  18. Optimization of technique for insertion of implants at the supra-acetabular corridor in pelvis and acetabular surgery.

    Science.gov (United States)

    Tosounidis, Theodoros H; Mauffrey, Cyril; Giannoudis, Peter V

    2018-01-01

    The technique for application of implants at the sciatic buttress has been well described in the pelvic and acetabular fracture reconstruction literature. We described a new use of the inlet-obturator oblique view for the identification of the anterior inferior iliac spine, which is the entry point of implants, and we provide a detailed fluoroscopic and radiographic description of this view. A small series of 15 patients who underwent an application of an anterior inferior pelvic external (supra-acetabular) fixator via this technique is presented. We consider the use of the obturator oblique for the identification of the entry point unnecessary, and we advocate for the use of only the inlet-obturator oblique and iliac oblique views when implants are applied to the sciatic buttress.

  19. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  20. The skill of surface registration in CT-based navigation system for total hip arthroplasty

    International Nuclear Information System (INIS)

    Hananouchi, T.; Sugano, N.; Nishii, T.; Miki, H.; Sakai, T.; Yoshikawa, H.; Iwana, D.; Yamamura, M.; Nakamura, N.

    2007-01-01

    Surface registration of the CT-based navigation system, which is a matching between computational and real spatial spaces, is a key step to guarantee the accuracy of navigation. However, it has not been well described how the accuracy is affected by the registration skill of surgeon. Here, we reported the difference of the registration error between eight surgeons with the experience of navigation and six apprentice surgeons. A cadaveric pelvic model with an acetabular cup was made to measure the skill and learning curve of registration. After surface registration, two cup angles (inclination and anteversion) were recorded in the navigation system and the variance of these cup angles in ten trials were compared between the experienced surgeons and apprentices. In addition, we investigated whether the accuracy of registration by the apprentices was improved by visual information on how to take the surface points. The results showed that there was statistically significant difference in the accuracy of registration between the two groups. The accuracy of the second ten trials after getting the visual information showed great improvements. (orig.)

  1. Decreased Lumbar Lordosis and Deficient Acetabular Coverage Are Risk Factors for Subchondral Insufficiency Fracture.

    Science.gov (United States)

    Jo, Woo Lam; Lee, Woo Suk; Chae, Dong Sik; Yang, Ick Hwan; Lee, Kyoung Min; Koo, Kyung Hoi

    2016-10-01

    Subchondral insufficiency fracture (SIF) of the femoral head occurs in the elderly and recipients of organ transplantation. Osteoporosis and deficient lateral coverage of the acetabulum are known risk factors for SIF. There has been no study about relation between spinopelvic alignment and anterior acetabular coverage with SIF. We therefore asked whether a decrease of lumbar lordosis and a deficiency in the anterior acetabular coverage are risk factors. We investigated 37 patients with SIF. There were 33 women and 4 men, and their mean age was 71.5 years (59-85 years). These 37 patients were matched with 37 controls for gender, age, height, weight, body mass index and bone mineral density. We compared the lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope, acetabular index, acetabular roof angle, acetabular head index, anterior center-edge angle and lateral center-edge angle. Lumbar lordosis, pelvic tilt, sacral slope, lateral center edge angle, anterior center edge angle, acetabular index and acetabular head index were significantly different between SIF group and control group. Lumbar lordosis (OR = 1.11), lateral center edge angle (OR = 1.30) and anterior center edge angle (OR = 1.27) had significant associations in multivariate analysis. Decreased lumbar lordosis and deficient anterior coverage of the acetabulum are risk factors for SIF as well as decreased lateral coverage of the acetabulum.

  2. ACCUWIND - Methods for classification of cup anemometers

    DEFF Research Database (Denmark)

    Dahlberg, J.-Å.; Friis Pedersen, Troels; Busche, P.

    2006-01-01

    the errors associated with the use of cup anemometers, and to develop a classification system for quantification of systematic errors of cup anemometers. This classification system has now been implementedin the IEC 61400-12-1 standard on power performance measurements in annex I and J. The classification...... of cup anemometers requires general external climatic operational ranges to be applied for the analysis of systematic errors. A Class A categoryclassification is connected to reasonably flat sites, and another Class B category is connected to complex terrain, General classification indices are the result...... developed in the CLASSCUP projectand earlier. A number of approaches including the use of two cup anemometer models, two methods of torque coefficient measurement, two angular response measurements, and inclusion and exclusion of influence of friction have been implemented in theclassification process...

  3. Wet-cupping removes oxidants and decreases oxidative stress.

    Science.gov (United States)

    Tagil, Suleyman Murat; Celik, Huseyin Tugrul; Ciftci, Sefa; Kazanci, Fatmanur Hacievliyagil; Arslan, Muzeyyen; Erdamar, Nazan; Kesik, Yunus; Erdamar, Husamettin; Dane, Senol

    2014-12-01

    Wet-cupping therapy is one of the oldest known medical techniques. Although it is widely used in various conditions such as acute\\chronic inflammation, infectious diseases, and immune system disorders, its mechanism of action is not fully known. In this study, we investigated the oxidative status as the first step to elucidate possible mechanisms of action of wet cupping. Wet cupping therapy is implemented to 31 healthy volunteers. Venous blood samples and Wet cupping blood samples were taken concurrently. Serum nitricoxide, malondialdehyde levels and activity of superoxide dismutase and myeloperoxidase were measured spectrophotometrically. Wet cupping blood had higher activity of myeloperoxidase, lower activity of superoxide dismutase, higher levels of malondialdehyde and nitricoxide compared to the venous blood. Wet cupping removes oxidants and decreases oxidative stress. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Menses cup evaluation study.

    Science.gov (United States)

    Cheng, M; Kung, R; Hannah, M; Wilansky, D; Shime, J

    1995-09-01

    To determine whether the menses cup is well tolerated by menstruating women. Prospective descriptive clinical study. Normal human volunteers in an academic research environment. Fifty-one menstruating women recruited between June to December 1991. Each participant was provided with two menses cups and an instruction sheet. Baseline information, including age, occupation, martial status, parity, description of menstrual flow, and current method used to cope with menstrual flow was collected. Subjects were asked to describe their experience with the cup at 1-, 2-, 6-, and 12-month intervals. The proportion of women who found the cup acceptable. The cup was used by 51 subjects for a total of 159 cycles. Overall, 23 women (45%) found the cup an acceptable method for coping with menses. Among 29 (57%) women who used the cup for two or more cycles, 62% found it acceptable. The menses cup may be an acceptable method for some women for coping with menstrual flow.

  5. Sacroiliac joint dysfunction as a reason for the development of acetabular retroversion: a new theory.

    Science.gov (United States)

    Cibulka, Michael T

    2014-05-01

    Acetabular retroversion has been recently implicated as an important factor in the development of femoral acetabular impingement and hip osteoarthritis. The proper function of the hip joint requires that the anatomic features of the acetabulum and femoral head complement one another. In acetabular retroversion, the alignment of the acetabulum is altered where it opens in a posterolaterally instead of anterior direction. Changes in acetabular orientation can occur with alterations in pelvic tilt (anterior/posterior), and pelvic rotation (left/right). An overlooked problem that alters pelvic tilt and rotation, often seen by physical therapists, is sacroiliac joint dysfunction. A unique feature that develops in patients with sacroiliac joint dysfunction (SIJD) is asymmetry between the left and right innominate bones that can alter pelvic tilt and rotation. This article puts forth a theory suggesting that acetabular retroversion may be produced by sacroiliac joint dysfunction.

  6. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    International Nuclear Information System (INIS)

    Aly, Abdel Rahman; Rajasekaran, Sathish; Obaid, Haron

    2013-01-01

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  7. [Innovation of characteristic medicinal cupping devices].

    Science.gov (United States)

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both Pcupping device was remarkably improved as compared with the traditional one at the two acupoints (both Pcupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  8. Migration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP).

    Science.gov (United States)

    Sköldenberg, Olof; Rysinska, Agata; Chammout, Ghazi; Salemyr, Mats; Muren, Olle; Bodén, Henrik; Eisler, Thomas

    2016-07-07

    In vitro, Vitamin-E-diffused, highly cross-linked polyethylene (PE) has been shown to have superior wear resistance and improved mechanical properties when compared to those of standard highly cross-linked PE liners used in total hip arthroplasty (THA). The aim of the study is to evaluate the safety of a new cemented acetabular cup with Vitamin-E-doped PE regarding migration, head penetration and clinical results. In this single-centre, double-blinded, randomised controlled trial, we will include 50 patients with primary hip osteoarthritis scheduled for THA and randomise them in a 1:1 ratio to a cemented cup with either argon gas-sterilised PE (control group) or Vitamin-E-diffused PE (vitamin-e group). All patients and the assessor of the primary outcome will be blinded and the same uncemented stem will be used for all participants. The primary end point will be proximal migration of the cup at 2 years after surgery measured with radiostereometry. Secondary end points include proximal migration at other follow-ups, total migration, femoral head penetration, clinical outcome scores and hip-related complications. Patients will be followed up at 3 months and at 1, 2, 5 and 10 years postoperatively. Results will be analysed using 95% CIs for the effect size. A regression model will also be used to adjust for stratification factors. The ethical committee at Karolinska Institutet has approved the study. The first results from the study will be disseminated to the medical community via presentations and publications in relevant medical journals when the last patient included has been followed up for 2 years. NCT02254980. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Computed tomography vs. digital radiography assessment for detection of osteolysis in asymptomatic patients with uncemented cups: a proposal for a new classification system based on computer tomography.

    Science.gov (United States)

    Sandgren, Buster; Crafoord, Joakim; Garellick, Göran; Carlsson, Lars; Weidenhielm, Lars; Olivecrona, Henrik

    2013-10-01

    Digital radiographic images in the anterior-posterior and lateral view have been gold standard for evaluation of peri-acetabular osteolysis for patients with an uncemented hip replacement. We compared digital radiographic images and computer tomography in detection of peri-acetabular osteolysis and devised a classification system based on computer tomography. Digital radiographs were compared with computer tomography on 206 hips, with a mean follow up 10 years after surgery. The patients had no clinical signs of osteolysis and none were planned for revision surgery. On digital radiographs, 192 cases had no osteolysis and only 14 cases had osteolysis. When using computer tomography there were 184 cases showing small or large osteolysis and only 22 patients had no osteolysis. A classification system for peri-acetabular osteolysis is proposed based on computer tomography that is easy to use on standard follow up evaluation. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Directory of Open Access Journals (Sweden)

    Baldev Dudani

    2015-01-01

    Conclusion: Bipolar hip arthroplasty (BHA using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage.

  11. From Baby Bottle to Cup: Choose Training Cups Carefully, Use Them Temporarily

    Science.gov (United States)

    FOR THE DENTAL PATIENT ... From baby bottle to cup Choose training cups carefully, use them temporarily T ooth decay can ... should encourage their children to drink from a cup by their first birthday. As you make the ...

  12. Spoon-to-Cup Fading as Treatment for Cup Drinking in a Child with Intestinal Failure

    Science.gov (United States)

    Groff, Rebecca A.; Piazza, Cathleen C.; Zeleny, Jason R.; Dempsey, Jack R.

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup. (Contains 2…

  13. SPOON-TO-CUP FADING AS TREATMENT FOR CUP DRINKING IN A CHILD WITH INTESTINAL FAILURE

    OpenAIRE

    Groff, Rebecca A; Piazza, Cathleen C; Zeleny, Jason R; Dempsey, Jack R

    2011-01-01

    We treated a child with intestinal failure who consumed solids on a spoon but not liquids from a cup. We used spoon-to-cup fading, which consisted of taping a spoon to a cup and then gradually moving the bowl of the spoon closer to the edge of the cup. Spoon-to-cup fading was effective for increasing consumption of liquids from a cup.

  14. Genetic theory – a suggested cupping therapy mechanism of action

    OpenAIRE

    Shaban , Tamer; Ravalia , Munir

    2017-01-01

    The Cupping Therapy mechanism of action is not clear. Cupping may increase local blood circulation, and may have an immunomodulation effect. Local and systemic effects of Cupping Therapy were reported. Genetic expression is a physiological process that regulates body functions. Genetic modulation is a reported acupuncture effect. In this article, the authors suggest genetic modulation theory as one of the possible mechanisms of action of cupping therapy.

  15. MRI morphometric hip comparison analysis of anterior acetabular labral tears

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Abdel Rahman [University of Saskatchewan, Department of Physical Medicine and Rehabilitation, Saskatoon, SK (Canada); Saskatoon City Hospital, Saskatoon, SK (Canada); Rajasekaran, Sathish [HealthPointe, Pain, Spine and Sport Medicine, Alberta (Canada); Obaid, Haron [Royal University Hospital, University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada)

    2013-09-15

    Anterior (3 o'clock) acetabular labral tears (AALTs) have been reported to be associated with iliopsoas impingement (IPI). However, no study has examined the association between anatomical bony variables of the hip joint and AALTs. The purpose of this study was to evaluate the association between AALTs, femoroacetabular impingement (FAI) and other bony variables of the hip. Seventy-six out of 274 hip MRI records met the inclusion criteria. Two independent blinded investigators evaluated the location of acetabular labral tears (ALTs), edema at the musculotendinous junction of the iliopsoas insertion, femoral neck anteversion angle, femoral neck shaft angle, acetabular anteversion angle, alpha angle, lateral central edge angle (LCEA), acetabular index, and acetabular depth. Comparison analyses between groups were performed. Twenty-two patients had no ALTs (controls), 19 patients had AALTs, and 35 patients had ALTs not isolated at the 3 o'clock position (25 with cam-bony deformities [FAI-cam] and 10 with pincer-bony deformities [FAI-pincer]). The alpha angle mean was significantly higher (p < 0.001) in the FAI-cam group (62.7 , 95 % confidence interval [CI]: 56.2-69.2 ) compared with the AALTs group (46.9 , 95 % CI: 40.1-53.7 ). The LCEA mean was significantly higher (p < 0.001) in FAI-pincer group (41.9 , 95 % CI: 39.3 -44.5 ) compared to AALTs group (29.4 , 95 % CI: 24.2 -34.6 ). There was no statistically significant difference in any of the bony variables between the controls and the AALTs group. Our study demonstrated that AALTs are pathologically distinct and not associated with FAI or other bony abnormalities. This supports the previous studies, which proposed that AALTs are associated with IPI. (orig.)

  16. Acetabular roof stress fracture: a rare cause of hip pain in children ...

    African Journals Online (AJOL)

    Stress fracture of acetabular roof is an unusual cause of hip pain. It is considered as an underdiagnosed entity. People who are more susceptible to experience this fracture are athletes, soldiers and dancers. We present the case of an 11 year old girl with a roof acetabular stress fracture for which the diagnosis and ...

  17. Cement-in-cement acetabular revision with a constrained tripolar component.

    Science.gov (United States)

    Leonidou, Andreas; Pagkalos, Joseph; Luscombe, Jonathan

    2012-02-17

    Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-in-cement revision is an established technique. However, the available clinical and experimental studies focus on femoral stem revision. The purpose of this study was to present a case of cement-in-cement acetabular revision with a constrained component for recurrent dislocations and to investigate the current best evidence for this technique. This article describes the case of a 74-year-old woman who underwent revision of a Charnley THR for recurrent low-energy dislocations. A tripolar constrained acetabular component was cemented over the primary cement mantle following removal of the original liner by reaming, roughening the surface, and thoroughly irrigating and drying the primary cement. Clinical and radiological results were good, with the Oxford Hip Score improving from 11 preoperatively to 24 at 6 months postoperatively. The good short-term results of this case and the current clinical and biomechanical data encourage the use of the cement-in-cement technique for acetabular revision. Careful irrigation, drying, and roughening of the primary surface are necessary. Copyright 2012, SLACK Incorporated.

  18. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study.

    Science.gov (United States)

    Gurgel, Henrique M C; Croci, Alberto T; Cabrita, Henrique A B A; Vicente, José Ricardo N; Leonhardt, Marcos C; Rodrigues, João Carlos

    2014-01-01

    In a study of the acetabular component in total hip arthroplasty, 20 hips were operated on using imageless navigation and 20 hips were operated on using the conventional method. The correct position of the acetabular component was evaluated with computed tomography, measuring the operative anteversion and the operative inclination and determining the cases inside Lewinnek's safe zone. The results were similar in all the analyses: a mean anteversion of 17.4° in the navigated group and 14.5° in the control group (P=.215); a mean inclination of 41.7° and 42.2° (P=.633); a mean deviation from the desired anteversion (15°) of 5.5° and 6.6° (P=.429); a mean deviation from the desired inclination of 3° and 3.2° (P=.783); and location inside the safe zone of 90% and 80% (P=.661). The acetabular component position's tomography analyses were similar whether using the imageless navigation or performing it conventionally. Published by Elsevier Inc.

  19. The translational regulator Cup controls NMJ presynaptic terminal morphology.

    Science.gov (United States)

    Menon, Kaushiki P; Carrillo, Robert A; Zinn, Kai

    2015-07-01

    During oogenesis and early embryonic development in Drosophila, translation of proteins from maternally deposited mRNAs is tightly controlled. We and others have previously shown that translational regulatory proteins that function during oogenesis also have essential roles in the nervous system. Here we examine the role of Cup in neuromuscular system development. Maternal Cup controls translation of localized mRNAs encoding the Oskar and Nanos proteins and binds to the general translation initiation factor eIF4E. In this paper, we show that zygotic Cup protein is localized to presynaptic terminals at larval neuromuscular junctions (NMJs). cup mutant NMJs have strong phenotypes characterized by the presence of small clustered boutons called satellite boutons. They also exhibit an increase in the frequency of spontaneous glutamate release events (mEPSPs). Reduction of eIF4E expression synergizes with partial loss of Cup expression to produce satellite bouton phenotypes. The presence of satellite boutons is often associated with increases in retrograde bone morphogenetic protein (BMP) signaling, and we show that synaptic BMP signaling is elevated in cup mutants. cup genetically interacts with two genes, EndoA and Dap160, that encode proteins involved in endocytosis that are also neuronal modulators of the BMP pathway. Endophilin protein, encoded by the EndoA gene, is downregulated in a cup mutant. Our results are consistent with a model in which Cup and eIF4E work together to ensure efficient localization and translation of endocytosis proteins in motor neurons and control the strength of the retrograde BMP signal. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2009-12-01

    Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.

  1. Ilaj bil hijamah (cupping therapy) in the Unani system of medicine: anecdotal practice to evidence based therapy.

    Science.gov (United States)

    Abbas Zaidi, S M; Jameel, S S; Jafri, Kehkashan; Khan, Shariq A; Ahmad, Ehsan

    2016-08-01

    Cupping (Hijamah) therapy is very well documented as a result of several thousand years of clinical experiences in Unani medicine. In this procedure, suction is created by various means either with or without bloodletting. Though this therapy is being widely practiced across the globe for treating many chronic and intractable ailments but many reports reveal its unscientific and improper practices which results in many complications. Therefore to develop standard operative procedures and to propose protocols of cupping therapy in various diseases is the need of hour. A thorough literature review of relevant journals and textbooks was performed to gather the maximum available data on cupping therapy. This paper seeks to introduce the general concepts of cupping therapy in Unani medicine and other traditional systems of medicine, shortcomings and limitations of the currently published studies and suggest ways to improve these technical/methodological flaws. In addition, the authors have also attempted to provide the cupping related materials, hypotheses, observations which will provide the researchers the base for evaluating their usefulness in future clinical trials.

  2. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects.

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. IV.

  3. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  4. Arthroscopic treatment of femoral nerve paresthesia caused by an acetabular paralabral cyst.

    Science.gov (United States)

    Kanauchi, Taira; Suganuma, Jun; Mochizuki, Ryuta; Uchikawa, Shinichi

    2014-05-01

    This report describes a rare case of femoral nerve paresthesia caused by an acetabular paralabral cyst of the hip joint. A 68-year-old woman presented with a 6-month history of right hip pain and paresthesia along the anterior thigh and radiating down to the anterior aspect of the knee. Radiography showed osteoarthritis with a narrowed joint space in the right hip joint. Magnetic resonance imaging showed a cyst with low T1- and high T2-weighted signal intensity arising from a labral tear at the anterior aspect of the acetabulum. The cyst was connected to the joint space and displaced the femoral nerve to the anteromedial side. The lesion was diagnosed as an acetabular paralabral cyst causing femoral neuropathy. Because the main symptom was femoral nerve paresthesia and the patient desired a less invasive procedure, arthroscopic labral repair was performed to stop synovial fluid flow to the paralabral cyst that was causing the femoral nerve paresthesia. After surgery, the cyst and femoral nerve paresthesia disappeared. At the 18-month follow-up, the patient had no recurrence. There have been several reports of neurovascular compression caused by the cyst around the hip joint. To the authors' knowledge, only 3 cases of acetabular paralabral cysts causing sciatica have been reported. The current patient appears to represent a rare case of an acetabular paralabral cyst causing femoral nerve paresthesia. The authors suggest that arthroscopic labral repair for an acetabular paralabral cyst causing neuropathy can be an option for patients who desire a less invasive procedure. Copyright 2014, SLACK Incorporated.

  5. [Effects of Surgically Treated Pelvic Ring and Acetabular Fractures on Postural Control].

    Science.gov (United States)

    Lang, P; Schnegelberger, A; Riesner, H-J; Stuby, F; Friemert, B; Palm, H-G

    2016-04-01

    The aim of surgical treatment of pelvic ring and acetabular fractures is to allow rapid mobilisation of patients in order to restore stance and gait stability (postural control), as this significantly correlates with a positive outcome. The regulation of postural stability is mainly controlled by transmission of proprioceptive stimuli. In addition, the pelvis serves as a connection between the legs and the spine and thus is also of great importance for mechanical stabilisation. It remains unclear whether surgical treatment of pelvic ring and acetabular fractures affects the regulation of postural control. Therefore, the aim of this study was to examine the impact of surgically treated pelvic ring and acetabular fractures on postural stability by means of computerised dynamic posturography (CDP) after a mean of 35 months and to compare the results with a healthy control group. A retrospective case control study of 38 patients with surgically treated pelvic ring and acetabular fractures and 38 healthy volunteers was carried out using CDP. The average time of follow-up was 35 (12-78) months. The most important outcome parameter in this investigation was the overall stability index (OSI). Hip joint mobility, the health-related quality of life (SF-12) and pain were supplementary outcome parameters. It was found that surgically treated pelvic ring and acetabular fractures had no influence on postural stability. The OSI was 2.1 ° in the patient group and 1.9 ° in the control group. There was no significant difference between the groups in hip joint mobility. A total of 52 % of patients showed no or only mild pain. Mean health-related quality of life was the same as in the total population. Surgically treated pelvic ring and acetabular fractures do not lead to deterioration in postural control in the mid term. This is of high prognostic importance for rapid mobilisation of the patients. Therefore no increase in the risk of falling is expected after successfully

  6. Measurement of acetabular morphology under three-dimensional reconstruction of CT and significance

    International Nuclear Information System (INIS)

    Han Yingying; Yang Qiwei; Lai Ying; Hao Shuang; Ma Hecheng; Xiao Chengshuang; Li Youqiong

    2011-01-01

    Objective: To measure the acetabular morphology of Chinese on CT three-dimensional (3D) reconstruction image, and provide the evidence on the prevention and treatment of hip disease. Methods: 96 cases (192 sides) of adult hip CT scans were reconstructed, the acetabular index (AA), center-edge (CE), ACE angle, anteversion angle (AVA), abduction angle (ABA), and vertical diameter (SID) were measured. Results: The total acetabular index was (8.78±5.34)°, of which male was (7.84±5.55)° and female was (9.60±5.06)°. The total CE was (33.59±5.91)°, of which male was (34.55±6.03)° and female was (32.78±5.70)°. The total ACE angle was (29.01±5.65)°, of which male was (28.02±5.94)° and female was (29.80±5.30)°. The total AVA was (20.92±5.55)°, of which male was (20.48±5.08)° and female was (21.25±5.89)°. The total ABA was (51.27±4.16)°, of which male was (51.71±4.37)° and female was (50.89±3.96)°. The total SID was (53.79±3.92) mm, of which male was (56.55±2.64) mm and female was (51.46±3.25) mm. Of the above data, there were statistical differences in the acetabular index, CE angle, ACE angle and acetabular diameter between men and women (P<0.05), Chinese and foreigners (P<0.05). While there was no statistical difference between the left and right sides (P>0.05). Conclusion: There are differences in acetabular morphology between men and women, Chinese and foreigners. Compared with simply using overseas data, it is better to study morphological parameters of native acetabula to instruct the preoperative preparation and operation of national total hip arthroplasty surgery. And it is meaningful to design national parameters. (authors)

  7. Application of Rapid Prototyping Pelvic Model for Patients with DDH to Facilitate Arthroplasty Planning: A Pilot Study.

    Science.gov (United States)

    Xu, Jie; Li, Deng; Ma, Ruo-fan; Barden, Bertram; Ding, Yue

    2015-11-01

    Total hip arthroplasty (THA) is challenging in cases of osteoarthritis secondary to developmental dysplasia of the hip (DDH). Acetabular deficiency makes the positioning of the acetabular component difficult. Computer tomography based, patient-individual three dimensional (3-D) rapid prototype technology (RPT)-models were used to plan the placement of acetabular cup so that a surgeon was able to identify pelvic structures, assess the ideal extent of reaming and determine the size of cup after a reconstructive procedure. Intraclass correlation coefficients (ICCs) were used to analyze the agreement between the sizes of chosen components on the basis of preoperative planning and the actual sizes used in the operation. The use of the 3-D RPT-model facilitates the surgical procedures due to better planning and improved orientation. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Normal microscopic architecture of acetabular labrum of hip joint: a qualitative original study with clinical aspects

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkantsinikoudis, Nikolaos; Dermon, Antonios; Kommata, Vassiliki; Papathanasiou, Jannis; Soukakos, Panagiotis; Dermon, Caterina

    2017-01-01

    Summary Background Normal histologic architecture of acetabular labrum, regarding presence of Free Nerve Endings (FNEs) and Nerve End Organs (NEOs) has been four times described. Nevertheless, elderly cadaveric specimens and individuals were recruited, leading to considerably high unreliability probability due to microscopic degenerative alterations. Aim of this paper is to analyze distribution pattern of FNEs and NEOs in acetabular labra of healthy middle-aged individuals, configuring thus more reliably acetabular labrum microscopic profile. Materials and methods Six patients with middle age 52 ± 2.5 years were enrolled in this study. Injury of acetabular labrum and normal hip radiograph were present in all cases. Patients were all subjected to successful hip hemi-arthroplasty and derived acetabular labra were subsequently histologically processed and observed under a compound microscope. Results FNEs and NEOs were detected in all specimens. All types of NEOs were identified, including Paccini, Golgi-Mazzoni, Ruffini and Krause corpuscles. FNEs and NEOs were both in ventral part and in chondral side of labrum predominantly detected. Conclusion FNEs and NEOs presence was greater in ventral side of labrum, being thus in partial agreement with previous studies results. Further study is required, in order to elucidate the exact acetabular labrum normal microscopic anatomy. Level of evidence IV. PMID:29264339

  9. Digestive Fistula Due to Acetabular Protrusion: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Carlos Marqués

    2017-12-01

    Full Text Available Intrapelvic migration of the acetabular component after primary or revision hip arthroplasty is a rare complication. We present a case of an intrapelvic migration of the acetabular component after a revision hip arthroplasty which led to an enteric fistula to the hip joint as well as to a sigmoid colon perforation.

  10. Cup tool use by squirrel monkeys.

    Science.gov (United States)

    Buckmaster, Christine L; Hyde, Shellie A; Parker, Karen J; Lyons, David M

    2015-12-01

    Captive-born male and female squirrel monkeys spontaneously 'invented' a cup tool use technique to Contain (i.e., hold and control) food they reduced into fragments for consumption and to Contain water collected from a valve to drink. Food cup use was observed more frequently than water cup use. Observations indicate that 68% (n = 39/57) of monkeys in this population used a cup (a plastic slip cap) to Contain food, and a subset of these monkeys, 10% (n = 4/39), also used a cup to Contain water. Cup use was optional and did not replace, but supplemented, the hand/arm-to-mouth eating and direct valve drinking exhibited by all members of the population. Strategies monkeys used to bring food and cups together for food processing activity at preferred upper-level perching areas, in the arboreal-like environment in which they lived, provides evidence that monkeys may plan food processing activity with the cups. Specifically, prior to cup use monkeys obtained a cup first before food, or obtained food and a cup from the floor simultaneously, before transporting both items to upper-level perching areas. After food processing activity with cups monkeys rarely dropped the cups and more often placed the cups onto perching. Monkeys subsequently returned to use cups that they previously placed on perching after food processing activity. The latter behavior is consistent with the possibility that monkeys may keep cups at preferred perching sites for future food processing activity and merits experimental investigation. Reports of spontaneous tool use by squirrel monkeys are rare and this is the first report of population-level tool use. These findings offer insights into the cognitive abilities of squirrel monkeys and provide a new context for behavior studies with this genus and for comparative studies with other primates. © 2015 Wiley Periodicals, Inc.

  11. Surgical Site Infection Following Fixation of Acetabular Fractures.

    Science.gov (United States)

    Iqbal, Faizan; Younus, Sajid; Asmatullah; Zia, Osama Bin; Khan, Naveed

    2017-09-01

    Acetabular fractures are mainly caused by high energy trauma. Surgical fixation of these fractures requires extensive surgical exposure which increases the length of operation and blood loss as well. This may increase the risk of surgical site infection. Our aim is to evaluate the prevalence of surgical site infections and the risk factors associated with it so as to minimize its chances. A total of 261 patients who underwent acetabular fracture surgery were retrospectively reviewed. Patients were divided into 2 groups, with or without surgical site infection. Factors examined include patients' gender, age, body mass index (BMI), time between injury and surgery, operative time, estimated blood loss, number of packed red blood cell transfused, length of total intensive care unit (ICU) stay, fracture type, surgical approach, smoking status, patients' comorbids and associated injuries. Fourteen patients (5.4%) developed surgical site infection. Out of 14 infections, 4 were superficial and 10 were deep. The factors that were found to be associated with surgical site infection following acetabular fracture fixation were prolonged operation time, increased BMI, prolonged ICU stay, larger amount of packed red blood cell transfused and associated genitourinary and abdominal trauma. In our study, we conclude that measures should be undertaken to attenuate the chances of surgical site infection in this major surgery by considering the risk factors significantly associated with it.

  12. CUP Syndrome-Metastatic Malignancy with Unknown Primary Tumor.

    Science.gov (United States)

    Zaun, Gregor; Schuler, Martin; Herrmann, Ken; Tannapfel, Andrea

    2018-03-09

    2-4% of newly diagnosed cases of malignant disease involve cancer of unknown primary (CUP). This mixed entity is one of the 6 most common types of malignant disease in Germany. Highly refined treatment strategies can now be offered to patients with CUP. This review is based on pertinent publications retrieved by a selective search in PubMed with an emphasis on articles from the past decade. The current guidelines and recommendations of specialty societies were also considered in the evaluation. CUP most commonly manifests itself as metastases to the lymph nodes, lungs, liver, or bones. With the aid of imaging studies, including functional hybrid imaging and further medical examination, a primary tumor can be discovered in up to 40% of patients initially diagnosed with CUP. Immunohistochemistry guided by histomorphology often enables precise characterization of the lesion and can be supplemented, in selected cases, by molecular-genetic diagnostic evaluation. The most commonly detected types of primary tumor are cancers of the lung, pancreas, liver, and biliary system. For patients with local metastases, surgical resection or radiotherapy with curative intent is usually indicated, sometimes in the framework of a multimodal treatment concept. The median 2-year survival of patients with disseminated CUP is only 20%. For such patients, specific types of systemic therapy are recommended on the basis of the diagnostic characterization of the disease. Immune-modulatory antibodies can be effective, particularly in the treatment of CUP that has been characterized with biomarkers, but should still be considered experimental at present. A combination of conventional and innovative diagnostic methods enables the provision of highly refined therapeutic strategies to patients with CUP who are undergoing treatment in interdisciplinary cancer centers.

  13. 3.0 T conventional hip MR and hip MR arthrography for the acetabular labral tears confirmed by arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Chun-Yan [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Wang, Jian-Quan [Department of Sports Medicine, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191,PR China (China); Zheng, Zhuo-Zhao, E-mail: zzhuozhao@aliyun.com [Department of Radiology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191 (China); Ren, A.-Hong [Department of Radiology, Beijing Daxing Hospital, 26 West Huangcun Road, Daxing District, Beijing 102600 (China)

    2014-10-15

    Highlights: • MR is the preferred imaging modality for diagnosing acetabular labral tears. • The diagnostic performance of MR arthrography are superior than conventional hip MR. • The hip MR arthrography is recommended for diagnosing acetabular labral lesions. - Abstract: Objective: To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears. Methods: 90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy. Results: 59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05). Conclusion: Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.

  14. Dual mobility cups provide biomechanical advantages in situations at risk for dislocation: a finite element analysis.

    Science.gov (United States)

    Terrier, Alexandre; Latypova, Adeliya; Guillemin, Maika; Parvex, Valérie; Guyen, Olivier

    2017-03-01

    Constrained devices, standard implants with large heads, and dual mobility systems have become popular options to manage instability after total hip arthroplasty (THA). Clinical results with these options have shown variable success rates and significant higher rates of aseptic loosening and mechanical failures with constrained implants. Literature suggests potential advantages of dual mobility, however little is known about its biomechanics. We present a comparative biomechanical study of a standard implant, a constrained implant, and a dual mobility system. A finite element analysis was developed to assess and compare these acetabular options with regard to the range of motion (ROM) to impingement, the angle of dislocation, the resistive torque, the volume of polyethylene (PE) with a stress above 80% of the elastic limit, and the interfacial cup/bone stress. Dual mobility implants provided the greatest ROM to impingement and allowed delaying subluxation and dislocation when compared to standard and constrained implants. Dual mobility also demonstrated the lowest resistive torque at subluxation while the constrained implant provided the greatest one. The lowest critical PE volume was observed with the dual mobility implant, and the highest stress at the interfaces was observed with the constrained implant. This study highlights the biomechanical advantages of dual mobility systems over constrained and standard implants, and is supported by the clinical results reported. Therefore, the use of dual mobility systems in situations at risk for instability should be advocated and constrained implants should be restricted to salvage situations.

  15. Cupping regulates local immunomodulation to activate neural-endocrine-immune worknet.

    Science.gov (United States)

    Guo, Yang; Chen, Bo; Wang, Dong-Qiang; Li, Ming-Yue; Lim, Calista Hui-Min; Guo, Yi; Chen, Zelin

    2017-08-01

    Research on cupping therapy is lacking at home and abroad. However, cupping and acupuncture therapy are both surface stimulation therapies. This paper suggests the mechanism of cupping therapy and proposes that the same mechanism underlies both cupping and acupuncture therapy. The microenvironment is changed when stimulating the surface of the skin, and physical signals transform into biological signals, which also interact with each other in the body. These signalling cascades activate the neuroendocrine-immune system, which produces the therapeutic effect. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements.

    Science.gov (United States)

    O'Dwyer Lancaster-Jones, O; Williams, S; Jennings, L M; Thompson, J; Isaac, G H; Fisher, J; Al-Hajjar, M

    2017-09-23

    The aim of this study was to develop a preclinical in vitro method to predict the occurrence and severity of edge loading condition associated with the dynamic separation of the centres of the head and cup (in the absence of impingement) for variations in surgical positioning of the cup. Specifically, this study investigated the effect of both the variations in the medial-lateral translational mismatch between the centres of the femoral head and acetabular cup and the variations in the cup inclination angles on the occurrence and magnitude of the dynamic separation, the severity of edge loading, and the wear rate of ceramic-on-ceramic hip replacement bearings in a multi-station hip joint simulator during a walking gait cycle. An increased mismatch between the centres of rotation of the femoral head and acetabular cup resulted in an increased level of dynamic separation and an increase in the severity of edge loading condition which led to increased wear rate in ceramic-on-ceramic bearings. Additionally for a given translational mismatch, an increase in the cup inclination angle gave rise to increased dynamic separation, worst edge loading conditions, and increased wear. To reduce the occurrence and severity of edge loading, the relative positions (the mismatch) of the centres of rotation of the head and the cup should be considered alongside the rotational position of the acetabular cup. This study has considered the combination of mechanical and tribological factors for the first time in the medial-lateral axis only, involving one rotational angle (inclination) and one translational mismatch. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017. © 2017 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.

  17. Cemented total hip replacement cable debris and acetabular construct durability.

    Science.gov (United States)

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and

  18. Histogram-driven cupping correction (HDCC) in CT

    Science.gov (United States)

    Kyriakou, Y.; Meyer, M.; Lapp, R.; Kalender, W. A.

    2010-04-01

    Typical cupping correction methods are pre-processing methods which require either pre-calibration measurements or simulations of standard objects to approximate and correct for beam hardening and scatter. Some of them require the knowledge of spectra, detector characteristics, etc. The aim of this work was to develop a practical histogram-driven cupping correction (HDCC) method to post-process the reconstructed images. We use a polynomial representation of the raw-data generated by forward projection of the reconstructed images; forward and backprojection are performed on graphics processing units (GPU). The coefficients of the polynomial are optimized using a simplex minimization of the joint entropy of the CT image and its gradient. The algorithm was evaluated using simulations and measurements of homogeneous and inhomogeneous phantoms. For the measurements a C-arm flat-detector CT (FD-CT) system with a 30×40 cm2 detector, a kilovoltage on board imager (radiation therapy simulator) and a micro-CT system were used. The algorithm reduced cupping artifacts both in simulations and measurements using a fourth-order polynomial and was in good agreement to the reference. The minimization algorithm required less than 70 iterations to adjust the coefficients only performing a linear combination of basis images, thus executing without time consuming operations. HDCC reduced cupping artifacts without the necessity of pre-calibration or other scan information enabling a retrospective improvement of CT image homogeneity. However, the method can work with other cupping correction algorithms or in a calibration manner, as well.

  19. Radiological landmarks for the safe extra-capsular placement of supra-acetabular half pins for external fixation.

    Science.gov (United States)

    Lidder, Surjit; Heidari, Nima; Gänsslen, Axel; Grechenig, Wolfgang

    2013-03-01

    Low anterior external fixators are constructed by placing half pins in the dense bone tunnel of the supra-acetabular region in an anterior to posterior direction. Although the placement of these pins is extra-articular, they may still breach the hip capsule on the anterior inferior iliac spine and thus be intra-capsular. We aim to provide radiological markers for the most superior fibres of the capsule to allow safe extra-capsular pin placement within the supra-acetabular bone tunnel. Thirteen cadaveric pelves were used for this study. The supra-acetabular bone tunnel was visualised with an image intensifier. The proximal most fibres of the hip joint capsule were marked with a K-wire so that their relation to the bone tunnel could be clearly seen on the images. Once all images were acquired they were calibrated and analysed to estimate the dimensions of the supra-acetabular bone tunnel and the reflection of the hip capsule. The median height of the bone tunnel was 23.6 mm (18.9-33.2) and maximum width was 11.4 mm (7.6-16.3). The inferior margin of the bone tunnel was 6.7 mm (1.1-14.5) superior to the acetabular dome, and the most proximal fibres of the capsule were 9.3 mm (4.7-6.1) superior to the acetabular dome. The inferior portion of the tunnel was 3.7 mm (0.3-8.9) within the joint. Half pins for the construction of a pelvic external fixator should be placed in the upper half of the supra-acetabular bone corridor to minimise the risk of intra-capsular placement.

  20. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  1. Efficient radiologic diagnosis of pelvic and acetabular trauma

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Mildenberger, P.; Thelen, M.; Rommens, P.M.

    2000-01-01

    In spite of the widespread availability of CT scanners, conventional X-ray radiographs remain the basic imaging modality in patients with pelvic and/or acetabular trauma. However, the extent of their use will depend on local utilities (e.g., availability of CT scanners) and on the patient's clinical condition. Regarding the inaccuracy of conventional radiography in the diagnosis of injuries of the dorsal pelvic ring and of the acetabulum, computed tomography represents the most important imaging modality in the clinically stable patient. CT provides an exact staging of the extent of trauma and allows for differentiation of pelvic instabilities. CT clearly demonstrates the severity of acetabular trauma and is superior in the detection of local complicating factors, i.e., impressions fractures and (sub-)luxations of the femoral head as well as free intraarticular fragments. CT findings provide the basis for definite treatment regimens of the injured patient. By extension of the examination, all relevant organs and systems (craniospinal, cardiovascular, gastrointestinal, respiratory, genitourinary) can be imaged during one session. The speed of spiral CT scanners and their diagnostic accuracy will play a major role in the management of, especially, polytraumatized patients. The indication for angiography with the option of therapeutic embolization exists if a pelvic bleeding persists even after reposition and operative fixation of the injury. (orig.) [de

  2. Minimum ten-year follow-up of acetabular fracture fixation from the Irish tertiary referral centre.

    LENUS (Irish Health Repository)

    Magill, Paul

    2012-04-01

    Successful outcome from acetabular fracture fixation is multi-factorial. Long-term results are not frequently reported. Pooling such data from high output centres will help progress acetabular fixation. This paper presents the first ten-year data from the Irish tertiary referral centre.

  3. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

    Science.gov (United States)

    Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H

    2017-03-01

    To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.

  4. Single- and dual energy QCT around acetabular cups in total hip arthroplasty using 3-dimensional segmentation

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder; Andersen, Poul Erik; Torfing, Trine

    of segmentation software and to compare bone mineral density (BMD) measurements in single- and dual energy CT (SECT and DECT) Materials and Methods: 24 male patients with total hip arthroplasty (12 cemented and 12 uncemented) were scanned and rescanned using SECT and virtual monochromatic DECT images. 3D- ROIs......Background: Bone density measurements around hip implants are challenged by artifacts and the complex anatomy of the acetabulum. We developed 3D segmentation software and used dual energy CT to reduce artifacts. Purpose / Aim of Study: To test the between-scan agreement and reliability...... the cemented cup the mean BMD for SECT was 523 mg/ccm with a between-scan difference of 14 mg/ccm, p=0.25 and 186 mg/ccm in DECT with a difference of 6 mg/ccm, p=0.15. ICC was >0.95 with more narrow limits of agreement in DECT compared with SECT. Computed tomography dose index (CTDI) was 25% higher with DECT...

  5. Is cupping blister harmful?-A proteomical analysis of blister fluid induced by cupping therapy and scald.

    Science.gov (United States)

    Liu, Zhidan; Chen, Chunlan; Li, Xiaoyan; Zhao, Chuang; Li, Zunyuan; Liang, Wei; Lin, Yufang

    2018-02-01

    Cupping therapy has a long history in traditional medicine especially in Asian countries. It was controversial whether cupping induced blisters are beneficial to healing effects, and the formation and content in the blisters remain unexplored. We aimed to identify and compare the molecular components of the blister fluid from the cupping therapy and the scalds to explore the necessary of inducing cupping induced blisters. Fluid sample of blisters from fifteen patients receiving cupping therapy (Cupping group) and scald burns (Scald group) were collected in this study. Proteins from the blisters were separated by two-dimensional electrophoresis (2D-gel) and further analyzed by mass spectrometry. In addition, the changes in particular proteins were confirmed by Western blotting. The protein components are significantly different between blister from cupping therapy and scalds. The immune responses, oxidative stress and metabolic related proteins (Ig lambda-2 chain C regions, Ig gamma-1 chain C region, hemopexin, prdx2, calmodulin, succinyl-CoA ligase and tetranectin) were increased, whereas the hemoglobin subunit beta was decreased in the Cupping group compared with the Scald group. Cupping induced blisters contain several proteins which relate to the activation of certain immune pathways including anti-oxidation, anti-apoptosis, tissue repairing and metabolic regulation. This proteomic analysis may indicate a significant clue to the mechanism study of cupping. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Spine–hip relations in patients with hip osteoarthritis

    Science.gov (United States)

    Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah

    2018-01-01

    Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844

  7. The CUP2 gene product regulates the expression of the CUP1 gene, coding for yeast metallothionein.

    OpenAIRE

    Welch, J; Fogel, S; Buchman, C; Karin, M

    1989-01-01

    The yeast CUP1 gene codes for a copper-binding protein similar to metallothionein. Copper sensitive cup1s strains contain a single copy of the CUP1 locus. Resistant strains (CUP1r) carry 12 or more multiple tandem copies. We isolated 12 ethyl methane sulfonate-induced copper sensitive mutants in a wild-type CUP1r parental strain, X2180-1A. Most mutants reduce the copper resistance phenotype only slightly. However, the mutant cup2 lowers resistance by nearly two orders of magnitude. We cloned ...

  8. Archive-cup insert for liquid-metal sampling

    International Nuclear Information System (INIS)

    Nelson, P.A.; Kolba, V.M.; Filewicz, E.C.; Holmes, J.T.

    1975-01-01

    An insert for collecting liquid-metal samples within a vertical casing including an elongated housing with an upper and a lower overflow seal of annular shape is described. The lower seal includes a centrally located pedestal on which a sample cup is disposed. Liquid metal enters the annulus of the upper seal and overflows into the cup which fills and overflows into the lower seal. Liquid-metal overflow from the lower seal is discharged from the insert. On cooling, the liquid metal trapped within the seals solidifies to hermetically isolate the metal sample within the cup. The device is particularly applicable for use with sampling systems on liquid metal-cooled reactors. (U.S.)

  9. Acetabular labrum of hip joint in osteoarthritis: A qualitative original study and short review of the literature.

    Science.gov (United States)

    Kapetanakis, S; Dermon, A; Gkantsinikoudis, N; Kommata, V; Soukakos, P; Dermon, C R

    2017-01-01

    Histological architecture of normal acetabular labrum regarding free nerve endings (FNEs) and mechanoreceptors (MRs) has been satisfactorily described in the literature. However, the presence of FNEs and MRs in acetabular labrum of hip joint has been analyzed only once in patients with osteoarthritis (OA). Aim of this article is to report histological distribution pattern of FNEs and MRs in acetabular labrum of patients with severe OA, at the same time conducting a comparison with normal acetabular labrum described in the literature. Seven patients with severe hip OA were enrolled in this study. Patient selection was assisted by the utilization of specific clinical scales delineated by the American College of Rheumatology. After successful total hip arthroplasty, tissue samples of acetabular labra of seven patients were histologically processed and stained with the gold standard chloride method, which was subsequently examined under a compound microscope. FNEs and MRs constituted the major histological structures. Identified MRs included Pacini corpuscles, Ruffini corpuscles, and Golgi-Mazzoni corpuscles. The presence of FNEs was predominant in the middle part of the acetabular labrum, featuring a remarkable decrease in peripheral parts. In contrast, MRs were detected basically in peripheral parts and less in the middle part. Differentiation of the distribution pattern of MRs and FNEs in acetabular labrum of hip joint is remarkable between normal patients and patients with severe OA. The abundance of FNEs in the middle part of the pathologic labrum is mainly responsible for the observed discrimination. A "conversion" of MRs to FNEs may occur during OA progression, modulating therefore this pattern as well as the upcoming clinical manifestations.

  10. Factitious panniculitis induced by cupping therapy.

    Science.gov (United States)

    Moon, Suk-Ho; Han, Hyun-Ho; Rhie, Jong-Won

    2011-11-01

    Cupping therapy is an alternative medical procedure that has been widely performed in Asian countries to relieve pain. It is known that there is no complication to this therapy, so many non-health care professionals have performed this procedure. However, there have been few reports on complications, such as iron deficiency anemia, hemorrhagic bullae, kelloids, vasovagal syncope, and foreign body reactions. Masses associated with panniculitis induced by cupping are extremely rare, and they require a unique approach.A 56-year-old woman presented with a 10-month history of multiple masses in the posterior neck and right shoulder areas. The patient repeatedly attempted cupping therapy by herself, and multiple palpable masses developed in the posterior neck and right shoulder area where cupping therapy had been performed. The masses were enlarged by repeated cupping, and they decreased in size when cupping was stopped. Among all lesions, the 2 masses with tenderness were surgically excised. The remaining masses resolved after cupping therapy was ceased. When a patient with subcutaneous mass has a history of cupping or trace of cupping marks, panniculitis induced by cupping should be suspected. The lesion seems to spontaneously resolve unless they are repeatedly stimulated. However, surgical resection is considered in patients with infections or severe tenderness as a complication.

  11. Biochemical and Cellular Assessment of Acetabular Chondral Flaps Identified During Hip Arthroscopy.

    Science.gov (United States)

    Hariri, Sanaz; Truntzer, Jeremy; Smith, Robert Lane; Safran, Marc R

    2015-06-01

    To analyze chondral flaps debrided during hip arthroscopy to determine their biochemical and cellular composition. Thirty-one full-thickness acetabular chondral flaps were collected during hip arthroscopy. Biochemical analysis was undertaken in 21 flaps from 20 patients, and cellular viability was determined in 10 flaps from 10 patients. Biochemical analysis included concentrations of (1) DNA (an indicator of chondrocyte content), (2) hydroxyproline (an indicator of collagen content), and (3) glycosaminoglycan (an indicator of chondrocyte biosynthesis). Higher values for these parameters indicated more healthy tissue. The flaps were examined to determine the percentage of viable chondrocytes. The percentage of acetabular chondral flap specimens that had concentrations within 1 SD of the mean values reported in previous normal cartilage studies was 38% for DNA, 0% for glycosaminoglycan, and 43% for hydroxyproline. The average cellular viability of our acetabular chondral flap specimens was 39% (SD, 14%). Only 2 of the 10 specimens had more than half the cells still viable. There was no correlation between (1) the gross examination of the joint or knowledge of the patient's demographic characteristics and symptoms and (2) biochemical properties and cell viability of the flap, with one exception: a degenerative appearance of the surrounding cartilage correlated with a higher hydroxyproline concentration. Although full-thickness acetabular chondral flaps can appear normal grossly, the biochemical properties and percentage of live chondrocytes in full-thickness chondral flaps encountered in hip arthroscopy show that this tissue is not normal. There has been recent interest in repairing chondral flaps encountered during hip arthroscopy. These data suggest that acetabular chondral flaps are not biochemically and cellularly normal. Although these flaps may still be valuable mechanically and/or as a scaffold in some conductive or inductive capacity, further study is

  12. STANDARDIZATION OF CUPPING THERAPY POINTS AND MECHANISM OF ACTION IN THE LIGHT OF SCIENCE

    OpenAIRE

    Dr. Izharul Hasan

    2018-01-01

    Now a day’s cupping therapy is an established therapeutic modality among Indian system of medicine as well as worldwide. Inspite of that, standard operative procedure (SOPs) for cupping therapy is yet to develop. In this paper author comprises the possible indications of cupping therapy along with procedures, application points, safety concerns, historical perspective, surgical operative standards described in traditional system of medicine as well as in the light of science. Cupping may be d...

  13. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Fischer, U.; Vosshenrich, R.

    1993-01-01

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.) [de

  14. Dielectric elastomer actuators for octopus inspired suction cups.

    Science.gov (United States)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  15. Dielectric elastomer actuators for octopus inspired suction cups

    International Nuclear Information System (INIS)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. (paper)

  16. Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study.

    Science.gov (United States)

    Yamada, Kazuki; Endo, Hirosuke; Tetsunaga, Tomonori; Miyake, Takamasa; Sanki, Tomoaki; Ozaki, Toshifumi

    2018-01-01

    The accuracy of various navigation systems used for total hip arthroplasty has been described, but no publications reported the accuracy of cup orientation in computed tomography (CT)-based 2D-3D (two-dimensional to three-dimensional) matched navigation. In a prospective, randomized controlled study, 80 hips including 44 with developmental dysplasia of the hips were divided into a CT-based 2D-3D matched navigation group (2D-3D group) and a paired-point matched navigation group (PPM group). The accuracy of cup orientation (absolute difference between the intraoperative record and the postoperative measurement) was compared between groups. Additionally, multiple logistic regression analysis was performed to evaluate patient factors affecting the accuracy of cup orientation in each navigation. The accuracy of cup inclination was 2.5° ± 2.2° in the 2D-3D group and 4.6° ± 3.3° in the PPM group (P = .0016). The accuracy of cup anteversion was 2.3° ± 1.7° in the 2D-3D group and 4.4° ± 3.3° in the PPM group (P = .0009). In the PPM group, the presence of roof osteophytes decreased the accuracy of cup inclination (odds ratio 8.27, P = .0140) and the absolute value of pelvic tilt had a negative influence on the accuracy of cup anteversion (odds ratio 1.27, P = .0222). In the 2D-3D group, patient factors had no effect on the accuracy of cup orientation. The accuracy of cup positioning in CT-based 2D-3D matched navigation was better than in paired-point matched navigation, and was not affected by patient factors. It is a useful system for even severely deformed pelvises such as developmental dysplasia of the hips. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    Science.gov (United States)

    Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim

    2009-01-21

    Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.

  18. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  19. Developing and validating a sham cupping device.

    Science.gov (United States)

    Lee, Myeong Soo; Kim, Jong-In; Kong, Jae Cheol; Lee, Dong-Hyo; Shin, Byung-Cheul

    2010-12-01

    The aims of this study were to develop a sham cupping device and to validate its use as a placebo control for healthy volunteers. A sham cupping device was developed by establishing a small hole to reduce the negative pressure after suction such that inner pressure could not be maintained in the cup. We enrolled 34 healthy participants to evaluate the validity of the sham cupping device as a placebo control. The participants were informed that they would receive either real or sham cupping and were asked which treatment they thought they had received. Other sensations and adverse events related to cupping therapy were investigated. 17 patients received real cupping therapy and 17 received sham cupping. The two groups felt similar sensations. There was a tendency for subjects to feel that real cupping created a stronger sensation than sham cupping (48.9±21.4 vs 33.3±20.3 on a 100mm visual analogue scale). There were only mild to moderate adverse events observed in both groups. We developed a new sham cupping device that seems to provide a credible control for real cupping therapy by producing little or no negative pressure. This conclusion was supported by a pilot study, but more rigorous research is warranted regarding the use of this device.

  20. Tantalum acetabular augments in one-stage exchange of infected total hip arthroplasty: a case-control study.

    Science.gov (United States)

    Klatte, Till Orla; Kendoff, Daniel; Sabihi, Reza; Kamath, Atul F; Rueger, Johannes M; Gehrke, Thorsten

    2014-07-01

    During the one-stage exchange procedure for periprosthetic joint infection (PJI) after total hip arthroplasty (THA), acetabular defects challenge reconstructive options. Porous tantalum augments are an established tool for addressing acetabular destruction in aseptic cases, but their utility in septic exchange is unknown. This retrospective case-control study presents the initial results of tantalum augmentation during one-stage exchange for PJI. Primary endpoints were rates of re-infection and short-term complications associated with this technique. Study patients had no higher risk of re-infection with equivalent durability at early follow-up with a re-infection rate in both groups of 4%. In conclusion, tantalum augments are a viable option for addressing acetabular defects in one-stage exchange for septic THA. Further study is necessary to assess long-term durability when compared to traditional techniques for acetabular reconstruction. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  2. Calculations for the excitation functions of the 63Cup, n63Zn, 63Cup, 2n62Zn and 65Cup, n65Zn reactions

    International Nuclear Information System (INIS)

    Gul, K.

    2001-01-01

    Calculations for the excitation functions of 63 Cup, n 63 Zn, 63 Cup, 2n 62 Zn and 65 Cup, n 65 Zn reactions have been carried out in 3-30 MeV energy range using statistical and pre-equilibrium nuclear reaction models. The calculations have been compared with reported measurements and discussed

  3. Increased Mortality in Elderly Patients with Sarcopenia and Acetabular Fractures.

    Science.gov (United States)

    Deren, Matthew E; Babu, Jacob; Cohen, Eric M; Machan, Jason; Born, Christopher T; Hayda, Roman

    2017-02-01

    Sarcopenia is a condition of clinically relevant loss of muscle mass and function. Acetabular fractures in elderly patients are common and difficult to treat. This study aimed to determine if sarcopenia is common in elderly patients with acetabular fractures and correlates with lower-energy mechanisms of injury, higher rates of complications, and higher mortality than patients with normal muscle mass. The Rhode Island Hospital Trauma Database was queried for patients who were ≥60 years of age from 2005 to 2014 using the International Classification of Diseases, Ninth Revision, code for closed acetabular fracture, 808.0. Charts were retrospectively reviewed for demographic data, operative intervention, mechanism of injury, mortality, comorbidities, and other factors. Computed tomography (CT) was used to determine the muscle cross-sectional area and to calculate the skeletal muscle index. The database revealed 192 patients coded for acetabular fracture; of these, 181 were correctly diagnosed. Ninety-nine patients had recorded body mass index (BMI) and adequate CT scans to measure the skeletal muscle index. Forty-two patients (42.4%) had sarcopenia, and 57 patients (57.6%) did not have sarcopenia. There were no significant differences in demographic characteristics between the groups with the exception of BMI and sex. BMI was higher in patients who did not have sarcopenia (31.7 kg/m) than it was in patients with sarcopenia (23.6 kg/m) (p sarcopenia at 76.2% (32 of 42 patients) than in patients without sarcopenia at 50.9% (29 of 57 patients). Fractures in patients without sarcopenia were associated with a higher-energy mechanism of injury in 78.9% of cases compared with 52.4% of cases of patients with sarcopenia (p = 0.005). Sarcopenia was significantly associated (p = 0.0419) with increased 1-year mortality (28.6%) compared with the absence of sarcopenia (12.3%). This association was even stronger if in-hospital mortality was excluded (p = 0.00074). Finally

  4. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  5. Acetabular fractures following rugby tackles: a case series

    LENUS (Irish Health Repository)

    Good, Daniel W

    2011-10-05

    Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old) who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting \\'the tackle\\' to only two players may well reduce the likelihood of this life-altering injury.

  6. 21 CFR 888.3320 - Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with a... Devices § 888.3320 Hip joint metal/metal semi-constrained, with a cemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with a cemented acetabular...

  7. 21 CFR 888.3330 - Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/metal semi-constrained, with an... Devices § 888.3330 Hip joint metal/metal semi-constrained, with an uncemented acetabular component, prosthesis. (a) Identification. A hip joint metal/metal semi-constrained, with an uncemented acetabular...

  8. Cranial acetabular retroversion is common in developmental dysplasia of the hip as assessed by the weight bearing position

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mikkelsen, Lone Rømer; Jacobsen, Steffen

    2010-01-01

    The appearance of acetabular version differs between the supine and weight bearing positions in developmental dysplasia of the hip. Weight bearing radiographic evaluation has been recommended to ensure the best coherence between symptoms, functional appearance, and hip deformities. Previous...... prevalence estimates of acetabular retroversion in dysplastic hips have been established in radiographs recorded with the patient supine and with inclusion only if pelvic tilt met standardized criteria. We assessed the prevalence and the extent of acetabular retroversion in dysplastic hip joints in weight...

  9. Alternative medicine: an update on cupping therapy.

    Science.gov (United States)

    Chen, B; Li, M-Y; Liu, P-D; Guo, Y; Chen, Z-L

    2015-07-01

    To know the research progress of cupping therapy all over the world, the authors analyze the research of cupping therapy in recent 5 years. It indicates that cupping therapy can be applied to extensive curable disease, but has poor clinical evidence. Some improvements in the mechanism research of cupping therapy have been made, but it needs further research. The adverse events of cupping therapy attract attention. The standardization of cupping therapy has emerged. © The Author 2014. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. [Application of blistering cupping].

    Science.gov (United States)

    Gu, Xingui; Chen, Zelin; Chen, Bo; Fan, Yihua; Chen, Xianghong

    2016-11-12

    Blistering cupping is special as eliminating wind and dampness as well as removing phlegm and blood stasis, and it achieves effects through suction. In this paper we reviewed relevant literature combined with clinical experience so as to summarize its operation attention through exploring the origin, mechanism and application. We divide the progress into the blistering period, the phlegm-stasis-eliminating period, and the escharosis period according to the changes of bubble and the things pulled out. Blistering cupping creates ways to eliminate concrete unhealthy influences through smoothing meridians and collaterals, such as phlegm and retained fluid, dampness and blood stasis. Thus chronic diseases are relieved. Also,we propose the rules of "blistering acupoints being related to disease location as well as the nature of acupoints and diseases". The therapy has been used to treat diseases of respiratory system, osteoarticular, skin and subcutaneous tissue, mental and behavioral disorders, and tumor, among which the effects of intractable diseases of respiratory and osteoarticular systems are definite. It deserves to be further explored and promoted.

  11. A retained menstrual cup.

    Science.gov (United States)

    Day, S

    2012-05-01

    A 20-year-old woman attended a genitourinary clinic with a retained vaginal Mooncup that she had inserted the night before. A Mooncup is one type of menstrual cup. On speculum examination the device was visualized high in the vagina and the cervix appeared firmly lodged within it. The physician experienced difficulty in retrieving the cup despite following product instructions. This case highlights a new adverse event with an increasingly used sanitation product. It is important that clinicians are familiar with the cup, its removal process and are able to counsel patients with retained devices on future correct placement.

  12. Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture

    Directory of Open Access Journals (Sweden)

    Robertsson Otto

    2010-08-01

    Full Text Available Abstract Background Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components. Methods We compared the dislocation rate in 56 consecutive patients operated with conventional (single mobility cemented acetabular components to that in 42 consecutive patients operated with dual articulation acetabular components. All the patients were operated via posterior approach and were followed up to one year postoperatively. Results There were 8 dislocations in the 56 patients having conventional components as compared to no dislocations in those 42 having dual articulation components (p = 0.01. The groups were similar with respect to age and gender distribution. Conclusions We conclude that the use of a cemented dual articulation acetabular component significantly reduces the dislocation rates in femoral neck fracture patients operated via posterior approach.

  13. Duoplasmatron with a nozzle type plasma expension cup

    International Nuclear Information System (INIS)

    Kobayashi, M.; Nishikawa, T.; Takagi, A.

    1974-01-01

    Various tests are described which were carried out in order to clarify the cause of the aberration existing in the beams extracted from a nozzle type plasma expansion cup. The tests involve the extraction electrodes having different edge shapes, gridded extraction electrodes, high-voltage facing electrodes at the cup exit making different angles with the axis, plasma cups having different contours at the exit, plasma cups gridded at the exit, biasing the cup exit with respect to anode, plasma cups having different ratios of the exit area to axial length, etc. The results show that the inward meniscus type distortion of the plasma boundary near the rim of plasma cup will be a dominant source for the aberration. Both proper shaping of the contour of the cup exit and biasing the cup exit reduced the aberration

  14. New is the well-forgotten old: The use of dry cupping in musculoskeletal medicine.

    Science.gov (United States)

    Rozenfeld, Evgeni; Kalichman, Leonid

    2016-01-01

    Cupping is an ancient technique used in treating pain and various disorders. Different techniques have been developed over time, however, applying a cup to create suction over a painful area, is common to all. Dry or fire cupping, used on the intact skin, leaves bluish circular hematomas. Recently, interest in cupping has re-emerged and subsequently, several studies have begun to investigate the mechanisms of cupping therapy. Mechanically, cupping increases blood circulation, whereas physiologically it activates the immune system and stimulates the mechanosensitive fibers, thus leading to a reduction in pain. There is initial scientific evidence that dry cupping is able to reduce musculoskeletal pain. Since cupping is an inexpensive, noninvasive and low-risk (if performed by a trained practitioner) therapeutic modality, we believe that it should be included in the arsenal of musculoskeletal medicine. It is essential to perform additional studies clarifying the biological mechanism and clinical effects of cupping. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  16. Acetabular retroversion as a rare cause of chronic hip pain: recognition of the ''figure-eight'' sign

    Energy Technology Data Exchange (ETDEWEB)

    Banks, Kevin P. [Brooke Army Medical Center, Department of Radiology, Fort Sam Houston, TX (United States); Grayson, David E. [Wilford Hall Medical Center, Department of Radiology, Lackland Air Force Base, TX (United States)

    2007-06-15

    While well-recognized in the orthopedic literature as a cause of chronic hip pain, acetabular retroversion has not been specifically described in the radiologic literature. Acetabular retroversion represents a particular form of hip dysplasia characterized by abnormal posterolateral orientation of the acetabulum. This pathophysiology predisposes the individual to subsequent anterior impingement of the femoral neck upon the anterior acetabular margin and fibrous labrum. Without treatment, cases may progress to damage of the anterior labrum and cartilage, with eventual early onset of osteoarthritic disease. This impinging condition has been described as occurring in isolation or as part of a complex dysplasia. We describe two cases of acetabular retroversion diagnosed by conventional radiographic evaluation of the pelvis, one in isolation and one occurring in the setting of a larger congenital syndrome. These cases illustrate the utility of the ''figure-eight'' sign in identifying abnormalities of acetabular version and thus assisting clinicians in properly identifying these individuals so that appropriate therapy may be instituted. (orig.)

  17. [Analysis on the adverse events of cupping therapy in the application].

    Science.gov (United States)

    Zhou, Xin; Ruan, Jing-wen; Xing, Bing-feng

    2014-10-01

    The deep analysis has been done on the cases of adverse events and common injury of cupping therapy encountered in recent years in terms of manipulation and patient's constitution. The adverse events of cupping therapy are commonly caused by improper manipulation of medical practitioners, ignoring contraindication and patient's constitution. Clinical practitioners should use cupping therapy cautiously, follow strictly the rules of standard manipulation and medical core system, pay attention to the contraindication and take strict precautions against the occurrence of adverse events.

  18. 21 CFR 884.5400 - Menstrual cup.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Menstrual cup. 884.5400 Section 884.5400 Food and... OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Therapeutic Devices § 884.5400 Menstrual cup. (a) Identification. A menstrual cup is a receptacle placed in the vagina to collect menstrual...

  19. A Procedure for Classification of Cup-Anemometers

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Paulsen, Uwe Schmidt

    1997-01-01

    The paper proposes a classification procedure for cup-anemometers based on similar principles as for power converters. A range of operational parameters are established within which the response of the cup-anemometer is evaluated. The characteristics of real cup-anemometers are fitted...... to a realistic 3D cup-anemometer model. Afterwards, the model is used to calculate the response under the range of operational conditions which are set up for the classification. Responses are compared to the normal linear calibration relationship, derived from Wind tunnel calibrations. Results of the 3D cup...

  20. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    International Nuclear Information System (INIS)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide

    2012-01-01

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  1. Femoral anteversion is correlated with acetabular version and coverage in Asian women with anterior and global deficient subgroups of hip dysplasia: a CT study

    Energy Technology Data Exchange (ETDEWEB)

    Akiyama, Mio; Nakashima, Yasuharu; Fujii, Masanori; Sato, Taishi; Yamamoto, Takuaki; Mawatari, Taro; Motomura, Goro; Matsuda, Shuichi; Iwamoto, Yukihide [Kyushu University, Department of Orthopaedic Surgery, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan)

    2012-11-15

    Morphological correlation between the acetabulum and femur at the hip joint is still controversial. We tested the hypothesis that femoral anteversion correlates with acetabular version and coverage in patients with developmental dysplasia of the hip (DDH). Using pelvic computed tomography (CT) images of 79 hips in 49 Asian women with DDH and 49 normal hips, we measured femoral anteversion, the axial and vertical acetabular version and the acetabular sector angle (ASA) to demarcate femoral head coverage. Depending on the location of the acetabular bone defect, dysplastic hips were divided into three subgroups: the anterior, global and posterior deficiency groups. We performed a comparative analysis between dysplastic and normal hips using the Wilcoxon rank sum test, and a relative analysis between femoral anteversion and acetabular measurements in dysplastic hips using Pearson's correlation coefficient. The amount of femoral anteversion in dysplastic hips was greater and more variable than in normal hips (p < 0.0001, p = 0.0277 respectively). Femoral anteversion in dysplastic hips correlated significantly with acetabular anteversion in the groups with anterior and global deficiency subgroups (p < 0.05, r = 0.2990, p < 0.05, r = 0.451 respectively), but not with the posterior deficiency subgroup. Femoral anteversion also correlated with vertical acetabular version. When acetabular coverage was examined, significant correlations were noted between femoral anteversion and anterior and superior coverage, but not with posterior coverage. These correlations were not observed in normal hips. Our results showed significantly greater and more variable femoral anteversion in DDH, and a significant correlation between femoral anteversion and acetabular version and coverage in DDH with anterior and global acetabular bone deficiency. (orig.)

  2. Combination acetabular radiofrequency ablation and cementoplasty using a navigational radiofrequency ablation device and ultrahigh viscosity cement: technical note.

    Science.gov (United States)

    Wallace, Adam N; Huang, Ambrose J; Vaswani, Devin; Chang, Randy O; Jennings, Jack W

    2016-03-01

    Percutaneous radiofrequency ablation and cementoplasty is an alternative palliative therapy for painful metastases involving axial load-bearing bones. This technical report describes the use of a navigational radiofrequency probe to ablate acetabular metastases from an anterior approach followed by instillation of ultrahigh viscosity cement under CT-fluoroscopic guidance. The tumor ablation databases of two institutions were retrospectively reviewed to identify patients who underwent combination acetabular radiofrequency ablation and cementoplasty using the STAR Tumor Ablation and StabiliT Vertebral Augmentation Systems (DFINE; San Jose, CA). Pre-procedure acetabular tumor volume was measured on cross-sectional imaging. Pre- and post-procedure pain scores were measured using the Numeric Rating Scale (10-point scale) and compared. Partial pain improvement was categorically defined as ≥ 2-point pain score reduction. Patients were evaluated for evidence of immediate complications. Electronic medical records were reviewed for evidence of delayed complications. During the study period, 12 patients with acetabular metastases were treated. The median tumor volume was 54.3 mL (range, 28.3-109.8 mL). Pre- and post-procedure pain scores were obtained from 92% (11/12) of the cohort. The median pre-procedure pain score was 8 (range, 3-10). Post-procedure pain scores were obtained 7 days (82%; 9/11), 11 days (9.1%; 1/11) or 21 days (9.1%; 1/11) after treatment. The median post-treatment pain score was 3 (range, 1-8), a statistically significant difference compared with pre-treatment (P = 0.002). Categorically, 73% (8/11) of patients reported partial pain relief after treatment. No immediate symptomatic complications occurred. Three patients (25%; 3/12) were discharged to hospice within 1 week of treatment. No delayed complications occurred in the remaining 75% (9/12) of patients during median clinical follow-up of 62 days (range, 14-178 days). Palliative percutaneous

  3. Determinación del desgaste del componente acetabular en prótesis totales de cadera. // Wear determination of acetabular component in total hip prosthesis.

    Directory of Open Access Journals (Sweden)

    G. García del Pino

    2002-01-01

    Full Text Available En este trabajo se realiza un estudio a través del Método de los Elementos Finitos “MEF” sobre el desgaste del componenteacetabular durante el ciclo de marcha y considerando algunos casos extremos de cargas como subir y bajar escaleras,levantarse de una silla, etc. Utilizando el MEF fueron modelados independientemente los componentes acetabular yfemoral de la prótesis total de cadera y puestos en contacto posteriormente. Fueron estudiadas varias posiciones delacetábulo así como diferentes casos de carga simulando pacientes con diferente peso corporal y actividades físicas. Paraevaluar los resultados se crearon rutinas en lenguaje C que organizaron los mismos para un tratamiento estadísticoposterior.Palabras claves: biomecánica, ortopedia, elementos finitos, modelación, desgaste, prótesis de cadera.___________________________________________________________________________Abstract.A wear study of acetabular component during the marching cycle, considering some extreme loads cases as: ascend anddescend stairways, get up from a seat, etc , by means of Finite Elements Method ( FEM , is carried out. The acetabular andfemoral component of the total hip prosthesis were independently modeled and placed in contact lastly. Several acetabulpositions were studied as well as different load cases, simulating patients with different body weight and different physicalactivities. To evaluate the results routines in C language were created in order to organized the same ones for a laterstatistical treatment.Key words. biomechanics, ortophedy, finite elements, modelation, wear, hip bone prosthesis.

  4. Design of high current bunching system and high power fast Faraday cup for high current LEBT at VECC

    International Nuclear Information System (INIS)

    Anuraag Misra, A.; Pandit, B.V.S.; Gautam Pal, C.

    2011-01-01

    A high current microwave ion source as described is currently operational at VECC. We are able to optimize 6.4 mA of proton current in the LEBT line of ion source. The cyclotron type of accelerators accept only a fraction of DC ion beam coming from ion source so a ion beam buncher is needed to increase the accepted current into the cyclotron. The buncher described in this paper is unique in its kind as it has to handle high beam loading power upto 400 W as it is designed to bunch few mA of proton beam currents at 80 keV beam energy. A sinusoidal quarter wave RF structure has been chosen to bunch the high current beam due to high Q achievable in comparison with other configurations. This buncher has been designed using CST Microwave studio 3D advanced code since the design frequency of our buncher is 42 MHz, we have provided the RF and vacuum window near the drift tube of buncher to avoid vacuum and multipacting problems and to keep maximum volume in air region. There is a provision of multipacting interlocks to shut off amplifier during multipacting. We have carried out a detailed electromagnetic and thermal design of the buncher in CST Microwave studio and simulated values of unloaded Q was calculated be 4000. We have estimated a power of 400 W to achieve gap (designed) voltage of 10 kV. This buncher is in advanced stage of fabrication. A high power fast Faraday cup is also designed to characterize the above mentioned high current bunching system. The fast Faraday cup is designed in 50 Ω coaxial geometry to transmit fast pulse of bunched ion beam. The design of Faraday cup was completed using ANSYS HFSS and a bandwidth of 1.75 GHz was achieved this faraday cup design was different from conventional Faraday cup design as we have designed the support and cooling lines at such a place on Faraday cup which do not disturb the electrical impedance of the cup. (author)

  5. Prophylactic post-operative radiotherapy prevents heterotopic ossification following traumatic acetabular fracture

    International Nuclear Information System (INIS)

    Meyer, Joseph T.; Hixson, William C.; Jennelle, Richard L. S.; Alonso, Jorge E.; Raben, David; Spencer, Sharon S.; Kim, Robert Y.

    1996-01-01

    Purpose/Objective: To determine the effect of post-operative radiation on the incidence of heterotopic ossification following traumatic acetabular fracture. Materials and Methods: A retrospective analysis was performed of the medical records and radiographs of all patients who received prophylactic radiotherapy to prevent heterotopic ossification. These results were compared to a similar group of patients receiving no prophylactic radiotherapy following traumatic acetabular fracture. Between 1987 and 1994, sixty-six patients received prophylactic radiotherapy to prevent heterotopic ossification. Results: Thirty-six patients (55%) received radiotherapy following operative repair of a traumatic acetabular fracture (median follow-up: 210 days). Three dose schedules were utilized: (28(36)) (77.8%) received 700 cGy/1 fx, (2(36)) (5.5%) 800 cGy/1 fx, and (6(36)) (16.7%) 1000 cGy/5 fxs. These patients were retrospectively compared with thirty-four patients who received similar operative management of traumatic acetabular fractures without post-operative radiotherapy (median follow-up: 378 days). Of the patients with heterotopic ossification, 96% developed it within 180 days. Complications and delayed wound healing rates were not significantly different in patients treated with or without post-operative radiotherapy, 6.4% and 6.3% respectively (p=0.49). The incidence of heterotopic ossification at last follow-up in patients treated with and without post-operative radiotherapy was (5(36)) (13.9%) and (19(34)) (55.9%), respectively (p=0.000332). For all patients, type of surgical approach was associated with development of heterotopic ossification: posterior, (7(38)) (18.4%), ilio-inguinal (1(3)) (33.3%), tri-radiate (13(19)) (68.4%), p=.000511. In patients receiving post-operative radiotherapy, variables associated with heterotopic ossification included dose (p=.00962), injury-to-radiation interval (p=.0038), and surgery-to-radiation interval (p=.0238). Fifty percent ((3

  6. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures.

    Science.gov (United States)

    Gupta, Sandeep; Singh, Jagdeep; Virk, Jagandeep Singh

    2017-06-01

    Complete visualization of certain acetabular fractures of posterior wall or column with cranial extension involving superior dome from standard surgical exposures is a challenge. Osteotomy of the greater trochanter has been used to enhance fracture visualization, especially the dome, in posterior and lateral exposures of the acetabulum. It also decreases the need for excessive muscle retraction. The purpose of the study was to investigate the outcome associated with trochanteric flip osteotomy in the management of certain acetabulum fractures. From January 2011 to December 2013, 25 displaced acetabular fractures were treated by open reduction and internal fixation. The fractures were managed using a Kocher-Langenbeck approach along with trochanteric flip osteotomy. At 3rd, 6th and 24th month follow-up, all patients had radiographic examination and underwent a final clinical evaluation based on the modified Merle d'Aubigne and Postel score. The strength of the abductors was assessed according to the Medical Research Council (MRC) grading system. Congruent reduction was achieved in all patients and all osteotomies healed within an average period of 3.8 months. All our patients were allowed full weight bearing at the end of 3 months and with no abductor lurch at the end of 6 months follow-up. There were no cases of avascular necrosis of femoral head. None of the patients had any neurovascular complication or infection by the end of the follow-up period. Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  7. MR-arthrography of the acetabular labrum - radiologic-pathologic correlation in 20 cadaveric hip joints; MR-Arthrographie des Labrum acetabulare - Radiologisch-anatomische Korrelation an 20 Leichenhueften

    Energy Technology Data Exchange (ETDEWEB)

    Brossmann, J.; Steffens, J.C.; Heller, M. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie; Ploetz, G.M.J.; Hassenpflug, J. [Kiel Univ. (Germany). Klinik fuer Orthopadie

    1999-08-01

    Purpose: To investigate frequency of acetabular labral lesions in elderly hip joints, and to determine sensitivity and specificity of MR arthrography (MRa) for the detection of these abnormalities. Materials and Methods: Twenty cadaveric hip joints were examined by MRa. For MRa, 15 ml of a solution of iodinated contrast solution (Solutrast 300) and Gd-DTPA (100:1) were injected under fluoroscopic guidance. MR imaging was performed on a 1.5 TM scanner (Vision, Siemens; FOV 16 cm, matrix 256x256, fat-suppressed 3D-FLASH). Multiplanar image reconstructions were done perpendicular to the acetabulum in the oblique-coronal, oblique-axial, and radial planes. The labral specimens were examined macroscopically. Results: In 12/20 hips (60%), a labral lesion was found on pathologic examination. In 7 specimens, the labrum was partially or completely detached in the weight-bearing superior region. One flap-like variant of the labrum was seen; in 4 hip joints, the labrum was degenerated (one cystic degeneration). Pathologic findings were confirmed by MRa in 8/12 specimens (sensitivity 67%). All degenerated labra were correctly diagnosed on MRa. Three small labral detachments and the flap-like variant were misinterpreted as being normal. There were no false positive findings (specificity 100%). The accuracy was 80%. Labral lesions were seen in 6/8 and in 6/12 of hips with and without osteoarthritis, respectively. Conclusion: MRa is well suited to delineate the acetabular labrum and to diagnose labral abnormalities. Detection of small labral detachments and anatomic variants is difficult and requires some experience. Labral lesions are correlated to osteoarthritis of the hip, but may be frequently seen in the elderly without underlying osteoarthritis. (orig.) [German] Ziel: Feststellung der Haeufigkeit von Laesionen des Labrum acetabulare bei aelteren Hueftgelenkspraeparaten und Untersuchung der Sensitivitaet und Spezifitaet der MR-Arthrographie (MRa) fuer die Darstellung dieser

  8. Acetabular fractures following rugby tackles: a case series

    Directory of Open Access Journals (Sweden)

    Morris Seamus

    2011-10-01

    Full Text Available Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting 'the tackle' to only two players may well reduce the likelihood of this life-altering injury.

  9. 21 CFR 872.6290 - Prophylaxis cup.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  10. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    Energy Technology Data Exchange (ETDEWEB)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong (Second Hospital Affiliated to the Medical College of Xi' an Jiaotong Univ., Xi' an Shaanxi (China))

    2009-08-15

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8+-2.1 mm and 7.1+-3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  11. Evaluation of Medial Acetabular Wall Bone Stock in Patients with Developmental Dysplasia of the Hip Using a Helical Computed Tomography Multiplanar Reconstruction Technique

    International Nuclear Information System (INIS)

    Rui Yu Liu; Kun Zheng Wang; Chun Sheng Wang; Xiao Qian Dang; Zhi Qin Tong

    2009-01-01

    Background: The technique of medialization has been used to reconstruct acetabula at the level of true acetabula in total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Appreciation of the bone stock in the medial acetabular wall is significant for making an optimal acetabular reconstruction plan and avoiding complications. Purpose: To evaluate the bone stock of the medial acetabular wall and its relation to the degree of subluxation in patients with DDH using computed tomography (CT). Material and Methods: Helical CT scans of 27 hips were obtained from 21 patients with osteoarthritis secondary to DDH who were scheduled for total hip arthroplasty. Eleven hips belonged to Crowe class I, while 16 hips belonged to Crowe class II/III. The raw CT data were reprocessed in various planes by scrolling multiplanar reformation (MPR). Acetabular opening, depth, and medial bone stock, as indicated by the minimum thickness of the medial acetabular wall, were measured in the transverse reformed MPR plane. Results: The minimum thicknesses of the medial acetabular wall in Crowe-I and Crowe-II/III hips were 3.8±2.1 mm and 7.1±3.1 mm, respectively, with statistically significant differences between the groups (P<0.05). Furthermore, the bone stock in the medial acetabular wall correlated with the degree of subluxation (R=0.69) and the acetabular depth (R= ;- ;0.71). Conclusion: There was significantly more bone stock in the medial acetabular wall in patients with higher-degree subluxation than there was in the less-severe class. This difference should be taken into consideration when reconstructing acetabula in THA in patients with DDH using the technique of medialization

  12. Characterisation and classification of RISOe P2546 cup anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.

    2004-03-01

    The characteristics of the RISOe P2546 cup anemometer were investigated in detail, and all data presented in figures and tables. The characteristics include: wind tunnel calibrations, including an accredited calibration; tilt response meas-urements for tilt angles from -40 deg. C to 40 deg. C; gust response measurements at 8m/s, 10,5m/s and 13m/s and turbulence intensities of 10%, 16% and 23%; step response measurements at step wind speeds 4, 8, 12 and 15m/s; measurement of torque characteristics at 8m/s; rotor inertia measurements and measurements of friction of bearings at temperatures -20 deg. C to 40 deg. C. The characteristics are fitted to a time domain cup anemometer model, and the cup anemometer is put into the CLASSCUP classification scheme. The characteristics are also compared to the requirements to cup anemometers in the Danish wind turbine certification system and the CD and CDV of the revision of the standard IEC 61400-12. (au)

  13. Fourier analysis of the aerodynamic behavior of cup anemometers

    International Nuclear Information System (INIS)

    Pindado, Santiago; Pérez, Imanol; Aguado, Maite

    2013-01-01

    The calibration results (the transfer function) of an anemometer equipped with several cup rotors were analyzed and correlated with the aerodynamic forces measured on the isolated cups in a wind tunnel. The correlation was based on a Fourier analysis of the normal-to-the-cup aerodynamic force. Three different cup shapes were studied: typical conical cups, elliptical cups and porous cups (conical-truncated shape). Results indicated a good correlation between the anemometer factor, K, and the ratio between the first two coefficients in the Fourier series decomposition of the normal-to-the-cup aerodynamic force. (paper)

  14. ACCUWIND - Methods for classification of cup anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, J.Aa.; Friis Pedersen, T.; Busche, P.

    2006-05-15

    Errors associated with the measurement of wind speed are the major sources of uncertainties in power performance testing of wind turbines. Field comparisons of well-calibrated anemometers show significant and not acceptable difference. The European CLASSCUP project posed the objectives to quantify the errors associated with the use of cup anemometers, and to develop a classification system for quantification of systematic errors of cup anemometers. This classification system has now been implemented in the IEC 61400-12-1 standard on power performance measurements in annex I and J. The classification of cup anemometers requires general external climatic operational ranges to be applied for the analysis of systematic errors. A Class A category classification is connected to reasonably flat sites, and another Class B category is connected to complex terrain, General classification indices are the result of assessment of systematic deviations. The present report focuses on methods that can be applied for assessment of such systematic deviations. A new alternative method for torque coefficient measurements at inclined flow have been developed, which have then been applied and compared to the existing methods developed in the CLASSCUP project and earlier. A number of approaches including the use of two cup anemometer models, two methods of torque coefficient measurement, two angular response measurements, and inclusion and exclusion of influence of friction have been implemented in the classification process in order to assess the robustness of methods. The results of the analysis are presented as classification indices, which are compared and discussed. (au)

  15. Fluctuation of Cup Orientation During Press-Fit Insertion: A Possible Cause of Malpositioning.

    Science.gov (United States)

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Sugano, Nobuhiko

    2015-10-01

    We evaluated real-time angular changes during press-fit cup insertion in 70 total hip arthroplasties. Inclination and anteversion cup angles on navigation system were recorded after each procedure of five hammer blows during cup insertion, and maximum deviated inclination (MDI) and anteversion (MDA) angles until the cup was fully seated were measured. We found 1 (1%) and 29 (41%) hips with increases and decreases in MDI of 5° or more, and 13 (19%) and 6 (8%) hips with increases and decreases in MDA of 5° or more, respectively. The MDI in men was significantly lower and the MDA for left-side surgery was significantly higher. Surgeons should pay attention to fluctuation in angular changes during cup insertion and may consider countermeasures to minimize cup malpositioning. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    International Nuclear Information System (INIS)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion

  17. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    Science.gov (United States)

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  18. Para-acetabular peritendinitis calcarea; its radiographic manifestations

    International Nuclear Information System (INIS)

    Kawashima, Akira; Murayama, Sadayuki; Ohuchida, Toshiyuki; Russell, W.J.

    1987-02-01

    Peritendinitis calcarea and os acetabuli have long been confused during interpretations of hip-joint radiographs. Such confusion is reflected in the medical literature. The present study differentiated these two entities according to their interval radiographic progression and regression. There were 137 instances of para-acetabular calcifications among 110 subjects (59 men and 51 women), whose mean age was 46.8 years at the time of their initial detection. Twenty-six of the subjects had lumbago, which was probably unrelated. Other abnormalities including narrowed intervertebral spaces, scoliosis, and spondylolysis were observed in 21 of the subjects. These could have been responsible for any symptoms they had had, but none of the subjects complained of local hip-joint pain when the radiographs in question were made. Ninety-three of these instances of calcification were reviewed by means of serial radiographs. Interval changes in the sizes and shapes of the calcifications occurred among 90 of them, indicative of the latent type of peritendinitis calcarea. No interval changes were noted in the remaining three cases, indicating they were secondary ossification centers; namely, os acetabuli. This study showed that in asymptomatic adults, most para-acetabular calcifications were really not os acetabuli, but actually peritendinitis calcarea. (author)

  19. The preliminary application of magnetic resonance arthrography in the diagnosis of acetabular labrale tears

    International Nuclear Information System (INIS)

    Hong Wen; Zhang Xuezhe; Wang Wu; Yue Debo; Wang Weiguo

    2010-01-01

    Objective: To investigate the application value of MR arthrography (MRA) in the diagnosis of acetabular lab ral tears. Methods: Fifteen patients with a high degree of suspected acetabular lab ral tears received fluoroscope-guided injection of the contrast media into the hip joint (hip arthrography) and fat-saturated spin-echo T 1 -weighted images were obtained in the coronal, sagittal, oblique-axial and radial planes. Hip arthroscopy was performed on 12 of them. Results: Lab ral tears which were diagnosed in 11 patients by hip MRA were confirmed at hip arthroscopy. One patient showed no MRA indication of lab ral tear, also showed normal on arthroscopy. Tear in the anterior-superior quadrant 10 cases of 12 joints (12/13), posterior-superior quadrant 1 case of a joint (1/13). In 11 patients who underwent arthroscopy, hip MRA diagnosed 3 (3/13) joints labrale tears in coronal planes, 10 (10/13) joints in sagittal planes and 13 (13/13) labrale tears in axial-oblique and radial planes. In 15 patients with 20 hip joints, 5 cases 6 joints (6/20) with normal acetabular sublabral sulcus were performed. Conclusions: MR arthrography of hip is a reliable method in the diagnosis of acetabular labrale tears. Scanning method should be included fat-saturated spin-echo T 1 -weighted images in sagittal and oblique-axial planes or sagittal plus radial planes. The diagnosis of torn posterior-inferior quadrant should pay attention to the existence of a normal variation. (authors)

  20. early experience of operative treatment of pelvic and acetabular

    African Journals Online (AJOL)

    Objective: To review early post-operative results of pelvic and acetabular fracture intern al fixation. Design: ... 600 needing operative treatment annually. ... Infection was controlled with debridement and antibiotics. All the patients in the study returned to their work except one who has yet to do so 5 months after his injury.

  1. Co-ordination of NDH and Cup proteins in CO2 uptake in cyanobacterium Synechocystis sp. PCC 6803.

    Science.gov (United States)

    Han, Xunling; Sun, Nan; Xu, Min; Mi, Hualing

    2017-06-01

    High and low affinity CO2-uptake systems containing CupA (NDH-1MS) and CupB (NDH-1MS'), respectively, have been identified in Synechocystis sp. PCC 6803, but it is yet unknown how the complexes function in CO2 uptake. In this work, we found that deletion of cupB significantly lowered the growth of cells, and deletion of both cupA and cupB seriously suppressed the growth below pH 7.0 even under 3% CO2. The rate of photosynthetic oxygen evolution was decreased slightly by deletion of cupA but significantly by deletion of cupB and more severely by deletion of both cupA and cupB, especially in response to changed pH conditions under 3% CO2. Furthermore, we found that assembly of CupB into NDH-1MS' was dependent on NdhD4 and NdhF4. NDH-1MS' was not affected in the NDH-1MS-degradation mutant and NDH-1MS was not affected in the NDH-1MS'-degradation mutants, indicating the existence of independent CO2-uptake systems under high CO2 conditions. The light-induced proton gradient across thylakoid membranes was significantly inhibited in ndhD-deletion mutants, suggesting that NdhDs functions in proton pumping. The carbonic anhydrase activity was suppressed partly in the cupA- or cupB-deletion mutant but severely in the mutant with both cupA and cupB deletion, indicating that CupA and CupB function in conversion of CO2 to HCO3-. In turn, deletion of cup genes lowered the transthylakoid membrane proton gradient and deletion of ndhDs decreased the CO2 hydration. Our results suggest that NDH-1M provides an alkaline region to activate Cup proteins involved in CO2 uptake. © The Author 2017. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  2. An updated review of the efficacy of cupping therapy.

    Science.gov (United States)

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted.

  3. An Updated Review of the Efficacy of Cupping Therapy

    Science.gov (United States)

    Cao, Huijuan; Li, Xun; Liu, Jianping

    2012-01-01

    Background Since 1950, traditional Chinese medicine (TCM) cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs) to evaluate the therapeutic effect of cupping therapy. Method Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. Results 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy), cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. Conclusions Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted. PMID:22389674

  4. An updated review of the efficacy of cupping therapy.

    Directory of Open Access Journals (Sweden)

    Huijuan Cao

    Full Text Available BACKGROUND: Since 1950, traditional Chinese medicine (TCM cupping therapy has been applied as a formal modality in hospitals throughout China and elsewhere in the world. Based on a previous systematic literature review of clinical studies on cupping therapy, this study presents a thorough review of randomized controlled trials (RCTs to evaluate the therapeutic effect of cupping therapy. METHOD: Six databases were searched for articles published through 2010. RCTs on cupping therapy for various diseases were included. Studies on cupping therapy combined with other TCM treatments versus non-TCM therapies were excluded. RESULTS: 135 RCTs published from 1992 through 2010 were identified. The studies were generally of low methodological quality. Diseases for which cupping therapy was commonly applied were herpes zoster, facial paralysis (Bell palsy, cough and dyspnea, acne, lumbar disc herniation, and cervical spondylosis. Wet cupping was used in most trials, followed by retained cupping, moving cupping, and flash cupping. Meta-analysis showed cupping therapy combined with other TCM treatments was significantly superior to other treatments alone in increasing the number of cured patients with herpes zoster, facial paralysis, acne, and cervical spondylosis. No serious adverse effects were reported in the trials. CONCLUSIONS: Numerous RCTs on cupping therapy have been conducted and published during the past decades. This review showed that cupping has potential effect in the treatment of herpes zoster and other specific conditions. However, further rigorously designed trials on its use for other conditions are warranted.

  5. Sound analysis of a cup drum

    International Nuclear Information System (INIS)

    Kim, Kun ho

    2012-01-01

    The International Young Physicists’ Tournament (IYPT) is a worldwide tournament that evaluates a high-school student's ability to solve various physics conundrums that have not been fully resolved in the past. The research presented here is my solution to the cup drum problem. The physics behind a cup drum has never been explored or modelled. A cup drum is a musical instrument that can generate different frequencies and amplitudes depending on the location of a cup held upside-down over, on or under a water surface. The tapping sound of a cup drum can be divided into two components: standing waves and plate vibration. By individually researching the nature of these two sounds, I arrived at conclusions that could accurately predict the frequencies in most cases. When the drum is very close to the surface, qualitative explanations are given. In addition, I examined the trend of the tapping sound amplitude at various distances and qualitatively explained the experimental results. (paper)

  6. [Progress of researches on the mechanism of cupping therapy].

    Science.gov (United States)

    Cui, Shuai; Cui, Jin

    2012-12-01

    Cupping therapy of Chinese medicine is able to relieve a variety of diseases or clinical conditions, which results from the comprehensive effects of multiple types of stimulation exerted onto the regional acupoint areas. Among the stimuli, the negative pressure from cupping is one of the main factors inducing therapeutic effects. In the present paper, the authors review development of researches on the underlying mechanism of therapeutic effects of cupping-negative pressure from 1) the factor of intra-cup negative pressure; 2) influence of intra-cup negative pressure on cup-blackspot formation; 3) influence of cupping on regional blood vessels and blood flow; 4) effect of cupping on regional ultrastructure of the capillary in the raw-surface tissue; 5) effect of cupping-negative pressure on regional endothelial cells; and 6) biological effects of negative pressure drainage. Generally, cupping induced negative pressure can dilate local blood vessels to improve microcirculation, promote capillary endothelial cells repair, accelerate granulation and angiogenesis, etc., in the regional tissues, normalizing the patients' functional state at last.

  7. Preparing for the America's Cup: A technological and a human challenge

    KAUST Repository

    Fischer, Martin

    2017-01-17

    The America\\'s Cup is the pinnacle event in sailing and it is the oldest sports trophy in the world. The trophy was originally awarded in 1851 for a race around the Isle of Wight, which was won by the schooner ムAmericaメ. It was subsequently renamed after the yacht and was donated to the New York Yacht Club under the terms of the Deed of Gift, which made the Cup available for perpetual international competition. The 35th America\\'s Cup will be held in May / June 2017 in Bermuda. The races will be sailed in 50-ft foiling catamarans. Instead of a main sail the boats feature a rigid wing. These boats are capable of sailing 3 times the wind speed, with top speeds reaching 45 knots. The lecture describes the technological and human endeavor to develop and prepare the boat and the crew. Developing an America\\'s Cup boat is a multidisciplinary effort. Excellence is required in such different fields as aerodynamics, hydrodynamics, structural analysis, advanced composite engineering and building, design of mechanical control systems, hydraulics, electronics and flight control, to name the most important ones. Since automatic control systems (autopilots) are forbidden in the America\\'s Cup rules there is a strong two-way feedback between sailing practicalities and the technological choices being made. Combine this with the management of a very tight build schedule for hulls, beams, foils, rudders and the wing and you get an idea what it means to prepare for the America\\'s Cup.

  8. Radiographic cup anteversion measurement corrected from pelvic tilt.

    Science.gov (United States)

    Wang, Liao; Thoreson, Andrew R; Trousdale, Robert T; Morrey, Bernard F; Dai, Kerong; An, Kai-Nan

    2017-11-01

    The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. History of cupping (Hijama): a narrative review of literature.

    Science.gov (United States)

    Qureshi, Naseem Akhtar; Ali, Gazzaffi Ibrahim; Abushanab, Tamer Shaban; El-Olemy, Ahmed Tawfik; Alqaed, Meshari Saleh; El-Subai, Ibrahim S; Al-Bedah, Abdullah M N

    2017-05-01

    Cupping (Hijama in Arabic) is an ancient, holistic method for the treatment of a variety of diseases. Though the exact origin of cupping therapy is a matter of controversy, its use has been documented in early Egyptian and Chinese medical practices. Diverse human civilizations have contributed to the historical development and continuation of cupping therapy. This narrative review describes the history of cupping, historical definitions, cupping instruments and uses of cupping therapy. Electronic searches of relevant databases (PubMed, Google Scholar and OvidSP) were conducted using keywords and Boolean operators. Manual searches and references of published articles and books were also conducted. A number of articles (N = 625) were retained for extensive review, and finally 83 articles were included in this paper. The historical descriptions of cupping therapy were found in ancient human civilizations of the Eastern and Western world. There were inconsistent data concerning the origin of cupping, definitions, instruments, procedures, definite advancements and research in Hijama over centuries. Cupping therapy fell out of favor in 17th and mid-18th centuries but recovered popularity in modern medicine. Currently, cupping therapy is used for health promotion, prophylaxis and treatment of a variety of diseases around the world. Cupping therapy with a good safety profile has a checkered history and is a well-recognized traditional method for managing medical conditions. Currently, the scope of cupping therapy is expanding, and a growing body of research is providing additional evidence-based data for the further advancement of cupping therapy in the treatment of a variety of diseases.

  10. Three-dimensional printing model improves morphological understanding in acetabular fracture learning: A multicenter, randomized, controlled study.

    Directory of Open Access Journals (Sweden)

    Zhenfei Huang

    Full Text Available Conventional education results in unsatisfactory morphological understanding of acetabular fractures due to lack of three-dimensional (3D details and tactile feedback of real fractures. Virtual reality (VR and 3D printing (3DP techniques are widely applied in teaching. The purpose of this study was to identify the effect of physical model (PM, VR and 3DP models in education of morphological understanding of acetabular fractures. 141 students were invited to participate in this study. Participants were equally and randomly assigned to the PM, VR and 3DP learning groups. Three-level objective tests were conducted to evaluate learning, including identifying anatomical landmarks, describing fracture lines, identifying classification, and inferring fracture mechanism. Four subjective questions were asked to evaluate the usability and value of instructional materials. Generally, the 3DP group showed a clear advantage over the PM and VR groups in objective tests, while there was no significant difference between the PM and VR groups. 3DP was considered to be the most valuable learning tool for understanding acetabular fractures. The findings demonstrate that 3DP modelling of real fractures is an effective learning instrument that can be used to understand the morphology of acetabular fractures and promote subjective interest.

  11. Early Versus Late Weight-Bearing Protocols for Surgically Managed Posterior Wall Acetabular Fractures.

    Science.gov (United States)

    Heare, Austin; Kramer, Nicholas; Salib, Christopher; Mauffrey, Cyril

    2017-07-01

    Despite overall improved outcomes with open reduction and internal fixation of acetabular fractures, posterior wall fractures show disproportionately poor results. The effect of weight bearing on outcomes of fracture management has been investigated in many lower extremity fractures, but evidence-based recommendations in posterior wall acetabular fractures are lacking. The authors systematically reviewed the current literature to determine if a difference in outcome exists between early and late postoperative weight-bearing protocols for surgically managed posterior wall acetabular fractures. PubMed and MEDLINE were searched for posterior wall acetabular fracture studies that included weight-bearing protocols and Merle d'Aubigné functional scores. Twelve studies were identified. Each study was classified as either early or late weight bearing. Early weight bearing was defined as full, unrestricted weight bearing at or before 12 weeks postoperatively. Late weight bearing was defined as restricted weight bearing for greater than 12 weeks postoperatively. The 2 categories were then compared by functional score using a 2-tailed t test and by complication rate using chi-square analysis. Six studies (152 fractures) were placed in the early weight-bearing category. Six studies (302 fractures) were placed in the late weight-bearing category. No significant difference in Merle d'Aubigné functional scores was found between the 2 groups. No difference was found regarding heterotopic ossification, avascular necrosis, superficial infections, total infections, or osteoarthritis. This systematic review found no difference in functional outcome scores or complication rates between early and late weight-bearing protocols for surgically treated posterior wall fractures. [Orthopedics. 2017: 40(4):e652-e657.]. Copyright 2017, SLACK Incorporated.

  12. Lamp with a truncated reflector cup

    Science.gov (United States)

    Li, Ming; Allen, Steven C.; Bazydola, Sarah; Ghiu, Camil-Daniel

    2013-10-15

    A lamp assembly, and method for making same. The lamp assembly includes first and second truncated reflector cups. The lamp assembly also includes at least one base plate disposed between the first and second truncated reflector cups, and a light engine disposed on a top surface of the at least one base plate. The light engine is configured to emit light to be reflected by one of the first and second truncated reflector cups.

  13. Athletic Departments' Operating Expenses as a Predictor of Their Directors' Cup Standing

    Science.gov (United States)

    Magner, Amber

    2014-01-01

    The NACDA Directors' Cup is a competition utilizing an unbiased scoring system that encourages a broad based athletic department as the standard for defining intercollegiate athletic success. Therefore, for NCAA DI athletic administrators the Directors' Cup should be the standard for defining intercollegiate athletic success. The purpose of this…

  14. Acetabular bone density and metal ions after metal-on-metal versus metal-on-polyethylene total hip arthroplasty; short-term results

    NARCIS (Netherlands)

    Zijlstra, Wierd P.; van der Veen, Hugo C.; van den Akker-Scheek, Inge; Zee, Mark J. M.; Bulstra, Sjoerd K.; van Raay, Jos J. A. M.

    Information on periprosthetic acetabular bone density is lacking for metal-on-metal total hip arthroplasties. These bearings use cobalt-chromium instead of titanium acetabular components, which could lead to stress shielding and hence periprosthetic bone loss. Cobalt and chromium ions have

  15. Characterisation and classification of RISØ P2546 cup anemometer

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2003-01-01

    The characteristics of the RISØ P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40° to 40°, gust responsemeasurements at 8m/s and turbulence intensities...... of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction ofbearings at temperatures -20°C to 40°C. Characteristics were fitted to a time domain cup anemometer model....... The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danishcertification system and in the IEC 61400-121 Committee Draft....

  16. Characterisation and classification of RISØ P2546 cup anemometer

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels

    2004-01-01

    The characteristics of the RISØ P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40° to 40°, gust responsemeasurements at 8m/s and turbulence intensities...... of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction ofbearings at temperatures -20°C to 40°C. Characteristics were fitted to a time domain cup anemometer model....... The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danishcertification system and in the IEC 61400-121 Committee Draft....

  17. GPU-powered model analysis with PySB/cupSODA.

    Science.gov (United States)

    Harris, Leonard A; Nobile, Marco S; Pino, James C; Lubbock, Alexander L R; Besozzi, Daniela; Mauri, Giancarlo; Cazzaniga, Paolo; Lopez, Carlos F

    2017-11-01

    A major barrier to the practical utilization of large, complex models of biochemical systems is the lack of open-source computational tools to evaluate model behaviors over high-dimensional parameter spaces. This is due to the high computational expense of performing thousands to millions of model simulations required for statistical analysis. To address this need, we have implemented a user-friendly interface between cupSODA, a GPU-powered kinetic simulator, and PySB, a Python-based modeling and simulation framework. For three example models of varying size, we show that for large numbers of simulations PySB/cupSODA achieves order-of-magnitude speedups relative to a CPU-based ordinary differential equation integrator. The PySB/cupSODA interface has been integrated into the PySB modeling framework (version 1.4.0), which can be installed from the Python Package Index (PyPI) using a Python package manager such as pip. cupSODA source code and precompiled binaries (Linux, Mac OS/X, Windows) are available at github.com/aresio/cupSODA (requires an Nvidia GPU; developer.nvidia.com/cuda-gpus). Additional information about PySB is available at pysb.org. paolo.cazzaniga@unibg.it or c.lopez@vanderbilt.edu. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  18. The pvc operon regulates the expression of the Pseudomonas aeruginosa fimbrial chaperone/usher pathway (cup genes.

    Directory of Open Access Journals (Sweden)

    Uzma Qaisar

    Full Text Available The Pseudomonas aeruginosa fimbrial structures encoded by the cup gene clusters (cupB and cupC contribute to its attachment to abiotic surfaces and biofilm formation. The P. aeruginosa pvcABCD gene cluster encodes enzymes that synthesize a novel isonitrile functionalized cumarin, paerucumarin. Paerucumarin has already been characterized chemically, but this is the first report elucidating its role in bacterial biology. We examined the relationship between the pvc operon and the cup gene clusters in the P. aeruginosa strain MPAO1. Mutations within the pvc genes compromised biofilm development and significantly reduced the expression of cupB1-6 and cupC1-3, as well as different genes of the cupB/cupC two-component regulatory systems, roc1/roc2. Adjacent to pvc is the transcriptional regulator ptxR. A ptxR mutation in MPAO1 significantly reduced the expression of the pvc genes, the cupB/cupC genes, and the roc1/roc2 genes. Overexpression of the intact chromosomally-encoded pvc operon by a ptxR plasmid significantly enhanced cupB2, cupC2, rocS1, and rocS2 expression and biofilm development. Exogenously added paerucumarin significantly increased the expression of cupB2, cupC2, rocS1 and rocS2 in the pvcA mutant. Our results suggest that pvc influences P. aeruginosa biofilm development through the cup gene clusters in a pathway that involves paerucumarin, PtxR, and different cup regulators.

  19. A geometric morphometric assessment of the optic cup in glaucoma.

    Science.gov (United States)

    Sanfilippo, Paul G; Cardini, Andrea; Sigal, Ian A; Ruddle, Jonathan B; Chua, Brian E; Hewitt, Alex W; Mackey, David A

    2010-09-01

    The morphologic appearance of the optic disc is of interest in glaucoma. In contrast to descriptive classification systems that are currently used, a quantitative approach to the analysis of optic disc morphology is required. Our goal was to determine the optimal method for quantifying optic cup shape by comparing traditional (ovality, form-factor and neuroretinal rim (NRR) width ratio) and geometric morphometric approaches. Left optic disc stereophotographs of 160 (80 normal and 80 glaucomatous (stratified by severity)) subjects were examined. The optic cup margins were stereoscopically delineated with a custom tracing system and saved as a series of discrete points. The geometric morphometric methods of elliptic Fourier analysis (EFA) and sliding semi-landmark analysis (SSLA) were used to eliminate variation unrelated to shape (e.g. size) and yield a series of shape variables. Differences in optic cup shape between normal and glaucoma groups were investigated. Discriminant functions were computed and the sensitivity and specificity of each technique determined. Receiver operator characteristic (ROC) curves were calculated for all methods and evaluated in their potential to discriminate between normal and glaucomatous eyes based on the shape variables. All geometric morphometric methods revealed differences between normal and glaucomatous eyes in optic cup shape, in addition to the traditional parameters of ovality, form-factor and NRR width ratio (pgeometric morphometric approach for discriminating between normal and glaucomatous eyes in optic cup shape is superior to that provided by traditional single parameter shape measures. Such analytical techniques could be incorporated into future automated optic disc screening modalities. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  20. Development and first experimental tests of Faraday cup array.

    Science.gov (United States)

    Prokůpek, J; Kaufman, J; Margarone, D; Krůs, M; Velyhan, A; Krása, J; Burris-Mog, T; Busold, S; Deppert, O; Cowan, T E; Korn, G

    2014-01-01

    A new type of Faraday cup, capable of detecting high energy charged particles produced in a high intensity laser-matter interaction environment, has recently been developed and demonstrated as a real-time detector based on the time-of-flight technique. An array of these Faraday cups was designed and constructed to cover different observation angles with respect to the target normal direction. Thus, it allows reconstruction of the spatial distribution of ion current density in the subcritical plasma region and the ability to visualise its time evolution through time-of-flight measurements, which cannot be achieved with standard laser optical interferometry. This is a unique method for two-dimensional visualisation of ion currents from laser-generated plasmas. A technical description of the new type of Faraday cup is introduced along with an ad hoc data analysis procedure. Experimental results obtained during campaigns at the Petawatt High-Energy Laser for Heavy Ion Experiments (GSI, Darmstadt) and at the Prague Asterix Laser System (AS CR) are presented. Advantages and limitations of the used diagnostic system are discussed.

  1. Burns induced by cupping therapy in a burn center in northeast china.

    Science.gov (United States)

    Jing-Chun, Zhao; Jia-Ao, Yu; Chun-Jing, Xian; Kai, Shi; Lai-Jin, Lu

    2014-07-01

    Cupping therapy as a curative skill has been developed and applied throughout history. Despite reports of adverse effects, this therapy is considered to be relatively safe with no systemic reviews documenting negative side effects. The aim of this study was to explore methods that avoid the adverse effects sometimes associated with this therapy. Clinical records of 14 outpatients and inpatients that visited the First Hospital of Jilin University (Changchun, China) for management of burn injuries caused by cupping therapy were retrospectively reviewed. Characteristics, history of injury, and treatment of each patient was collected and analyzed. Burn injury induced by cupping therapy was not uncommon. Most of the injuries were mild to moderate and cured by conservative methods without severe complications. The use of wet cupping was more prevalent among injured patients than dry cupping. Cupping therapy as an ancient alternative treatment is still popular with a large number of devoted practitioners. Although there is the potential for injury during the application of this therapy, this is mostly preventable. Standardized training for health care professionals and increased the awareness among the public about the proper methods to administer this therapy to avoid adverse effects is important.

  2. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    Energy Technology Data Exchange (ETDEWEB)

    Chun, K.A. [The Catholic University of Korea Uijongbu St. Mary' s Hospital, Department of Radiology, Uijongbu, Kyunggi-Do 480-130 (Korea); University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States); Morcuende, J. [University of Iowa Hospitals and Clinics, Department of Orthopaedic Surgery, Iowa City (United States); El-Khoury, G.Y. [University of Iowa Hospitals and Clinics, Department of Radiology, Iowa City (United States)

    2004-12-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  3. Entrapment of the acetabular labrum following reduction of traumatic hip dislocation in a child

    International Nuclear Information System (INIS)

    Chun, K.A.; Morcuende, J.; El-Khoury, G.Y.

    2004-01-01

    In traumatic hip dislocation, concentric reduction can be prevented by various causes. Soft-tissue interposition, such as entrapment of the acetabular labrum, is a rare but important cause of failed reduction of a hip. Early diagnosis of incomplete reduction due to interposition of soft tissue is important, because delayed treatment is associated with a greater incidence of avascular necrosis of the femoral head and early onset of osteoarthritis. This report describes a case of acetabular labral entrapment following reduction of traumatic hip dislocation in a child. The importance of CT and MRI in arriving at an early diagnosis is emphasized. (orig.)

  4. Characterisation and classification of RISOe P2546 cup anemometer

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.

    2003-04-01

    The characteristics of the RISOe P2546 cup anemometer were investigated in detail by wind tunnel and laboratory tests. The characteristics include accredited calibration, tilt response measurements for tilt angles between -40 degC to 40 degC, gust response measurements at 8m/s and turbulence intensities of 10%, 16% and 23%, step response measurements at step wind speeds 3,7, 8, 11,9 and 15,2m/s, measurement of torque characteristics at 8m/s, rotor inertia measurements and measurements of friction of bearings at temperatures -20 degC to 40 degC. Characteristics were fitted to a time domain cup anemometer model. The characteristics were transformed into the CLASSCUP classification scheme, and were related to the cup anemometer requirements in the Danish certification system and in the IEC 61400-121 Committee Draft. (au)

  5. [Posterior partial trochanteric osteotomy for the treatment of the roof involved acetabular fractures].

    Science.gov (United States)

    Wang, Pan-Feng; Xu, Shuo-Gui; Zhang, Chun-Cai; Fu, Qing-Ge; Zhang, Yun-Tong; Liu, Xin-Wei; Niu, Yun-Fei; Tang, Yang

    2013-11-01

    To introduce a new trochanteric osteotomy,and evaluate the outcome of the procedure combined a posterior lateral approach in treating acetabular fractures which involving the roof. Between March 2007 and Novmber 2010,30 patients with displaced acetabular fractures involving the dome need trochanteric osteotomy were retrospectively reviewed. There were 21 males and 9 females,ranging in age from 18 to 70 years with an average of 35.2 years at the time of injury. According to Letournel-Judet classification, there were 10 posterior wall fractures,7 posterior column fractures,5 transverse fractures, 2 T-shape fractures, 1 transverse associated with posterior wall fracture, 3 posterior column and wall fractures and 2 bicolumn fractures. The standards of Matta,the modified Merle d'Aubigne-Postel, Medical Research Council were respectively used to evaluate the reduction result, function of hip joint and the strength of hip abduction. All patients were followed up with an average time of 25 months (18 to 40) and all osteotomy sites obtained bone union with an average time of 8.4 weeks (6 to 12). No bone non-union, bone block displaceing, internal fixation looseing and breaking,infection of deep part were found. Seventeen patients got anatomic reduction, 12 got satisfied reduction, and 1 got unsatisfied result according to the criteria of Matta. At final follow-up, function of hip joint obtained excellent results in 11 cases, good in 15, fair in 3 and poor in 1. The strength of the abductors of 3 patients were grade 4 and 27 patients were grade 5. Posterior partial great trochanteric osteotomy can enhance the exposure and provide a more accurate reduction and degrade the difficulty of acetabular fracture fixation without increasing the risk of complications. The method provide a new way for the treatment of the roof involved acetabular fractures.

  6. Psychological experiences in South African society before the 2010 FIFA World Cup from the systems psychodynamic and positive psychology perspectives

    Directory of Open Access Journals (Sweden)

    Pieter Koortzen

    2012-05-01

    Research purpose: The objective of this study was to analyse and describe the psychological experiences of South Africans before the 2010 FIFA World Cup. Research design, approach and method: The researchers conducted the study from the systems psychodynamic and positive psychology perspectives. The study comprised a qualitative, explorative and social phenomenological study. The researchers conducted interviews with a wide range of their colleagues and clients. Main findings: The results seemed to indicate that South Africans had had a number of positive and negative experiences before the 2010 FIFA World Cup. Practical/managerial implications: The researchers presented the findings as a number of systems psychodynamic and positive psychology themes. Contribution/value-add: This study presents original research that contributes valuable new knowledge to the positive psychology and systems psychodynamic perspectives.

  7. The role of trochanteric flip osteotomy in fixation of certain acetabular fractures

    Directory of Open Access Journals (Sweden)

    Sandeep Gupta

    2017-06-01

    Conclusion: Trochanteric flip osteotomy is a very effective technique to fix certain acetabular fractures especially those with dome involvement. It is more accurate and associated with no significant complications compared with conventional way.

  8. Origin and evolution of cup-shaped structures on leached nuclear waste containment glass surfaces

    International Nuclear Information System (INIS)

    Dubois, C.; Villa, F.; Chambaudet, A.; Vernaz, E.

    1994-01-01

    A three-dimensional surface microanalysis system equipped with a sensitive topographical probe was used to quantify the evolution of cup-shaped structures formed by aqueous leaching of nuclear waste containment glass. A model of the dissolution phenomenon provides satisfactory correlation between calculated and measured cup radius and depth. Dissolution cups form from cracks on the initially cut glass surface. Large cracks control the phenomenon by forming the largest cups, which gradually absorb smaller ones. The evolution of the size and shape of the dissolution cups was described by a model that assumes a constant dissolution rate on the surface, diminishing with crack depth. The best fit with the experimental data was obtained with a dissolution rate one hundred times lower at the bottom of the crack than at the surface. Moreover, it is predictable that all the cups will gradually disappear as they grow larger and flatter over a leaching period of some 2 years, for the glass composition and experimental leaching procedures used in this work

  9. Reliability of ultrasonographic measurements in suspected patients of developmental dysplasia of the hip and correlation with the acetabular index

    Directory of Open Access Journals (Sweden)

    Cem Copuroglu

    2011-01-01

    Full Text Available Background: Ultrasonography is accepted as a useful imaging modality in the early detection of developmental dysplasia of the hip (DDH. Early detection and early treatment of DDH prevents hip dislocation and related physical, social, economic, and psychological problems. The purpose of this study was to evaluate the reliability of ultrasonographic and roentgenographic measurements measured by seven different observers. Materials and Methods: The alpha angles of 66 hips in 33 patients were measured using the Graf method by seven different observers. Acetabular index degrees on plane roentgenograms were measured in order to assess the correlation between the ultrasonographic alpha angle and the radiographic acetabular index, which both show the bony acetabular depth, retrospectively. Results: The interclass correlation coefficient, measuring the interobserver reliability, was high and statistically significant for the ultrasonographic measurements. There was a negative correlation between the alpha angle and the acetabular index. Conclusions: Ultrasonography, when applied properly, is a reliable technique between different observers, in the diagnosis and follow up of DDH. When assessed concomitantly with the roentgenographic measurements, the results are reliable and statistically meaningful.

  10. Earliest directly-dated human skull-cups.

    Directory of Open Access Journals (Sweden)

    Silvia M Bello

    Full Text Available BACKGROUND: The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP and skull-cup preparation is an element of this tradition. PRINCIPAL FINDINGS: Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow, accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also 'retouched', possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. CONCLUSIONS: Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles.

  11. Safety of cupping during bevacizumab therapy.

    Science.gov (United States)

    Klempner, Samuel J; Costa, Daniel B; Wu, Peggy A; Ariyabuddhiphongs, Kim D

    2013-08-01

    This study reports on the safety of the complementary and alternative medicine (CAM) practice of cupping in a patient undergoing concomitant therapy with bevacizumab for advanced non-small-cell lung cancer (NSCLC), and raises awareness of the need for improved communication between CAM practitioners and oncologists during the care of patients with cancer. The practice of cupping generates local hyperemia, disrupts superficial vasculature in the dermis, and leads to cutaneous lesions including circular erythema, edema, and subsequently ecchymosis. There are no data on the safety of cupping in patients being treated with bevacizumab. This is a single-institution case report. The setting for this study was a tertiary-care academic medical center. A patient with advanced NSCLC received four cycles of carboplatin AUC 6, paclitaxel 200 mg/m(2), and bevacizumab 15 mg/kg, and was continued on every-3-week maintenance bevacizumab 15 mg/kg. The patient underwent glass dry cupping during cycle six of maintenance bevacizumab treatment without overt cutaneous adverse events or bleeding. The patient did not realize he should have communicated his cupping plans or recent bevacizumab treatment with his providers.

  12. Cam deformity and acetabular dysplasia as risk factors for hip osteoarthritis

    NARCIS (Netherlands)

    Hosnijeh, Fatemeh Saberi; Zuiderwijk, Maria E; Versteeg, Mathijs; Smeele, Hieronymus T W; Hofman, Albert; Uitterlinden, André G; Agricola, Rintje; Oei, Edwin H G; Waarsing, Jan H; Bierma-Zeinstra, Sita M; van Meurs, Joyce B J

    2017-01-01

    Objective: Cam deformity and acetabular dysplasia have been recognized as relevant risk factors for hip osteoarthritis (OA) in a few prospective studies with limited sample sizes. To date, however, no evidence is available from prospective studies regarding whether the magnitude of these

  13. Femoro-acetabular impingement and hip pain with conventionally normal x-rays.

    LENUS (Irish Health Repository)

    Baker, J F

    2010-06-01

    There has in recent years been a fundamental change in the understanding of hip pain in the young adult and hip pain without plain radiographic findings of arthritis. Pain in these groups has long represented a diagnostic and therapeutic challenge. With new appreciation of hip biomechanics, pathological processes and the arrival of modern imaging modalities we now have a greater understanding of non-arthritic hip pathology. One of the commonest yet least well recognized \\'new\\' diagnoses around the hip is femoro-acetabular impingement (FAI). FAI is a developmental condition of the hip joint that is associated with abnormal anatomical configuration and thus joint mechanics on either the femoral or acetabular sides or both. It is hypothesized to have a variety of precipitants and may ultimately lead to labral and chondral injury and what has previously been referred to as \\'primary\\' or \\'idiopathic\\' hip osteoarthritis.

  14. Paradoxical, Cupping-Induced Localized Psoriasis: A Koebner Phenomenon.

    Science.gov (United States)

    Vender, Reid; Vender, Ronald

    2015-01-01

    Cupping therapy is a traditional Chinese medicine used to heal psoriasis. The Koebner phenomenon is the occurrence of psoriatic lesions at the site of cutaneous injury. To describe the first case of biopsy-proven cupping-induced localized psoriasis, an example of the Koebner phenomenon. The histopathology of the lesions is described. A brief review of the literature regarding cupping therapy and its efficacy are discussed. A 45-year-old Asian male presented himself to the dermatology clinic for further treatment of his psoriasis. Four unusually circular plaques on the lower back were discovered. Pathologic diagnosis revealed an early lesion of psoriasis. on further inquiry, the patient admitted to undergoing a recent "cupping" procedure in an attempt to cure his condition. The efficacy of cupping therapy is controversial, and psoriatic patients may develop localized psoriasis through koebnerization as a result of cupping therapy rather than achieve desirable therapeutic benefits. © 2014 Canadian Dermatology Association.

  15. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    Directory of Open Access Journals (Sweden)

    Xuezhi Lin

    2018-01-01

    Full Text Available Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM but the biocompatibility of these three-dimensional printing (3D-printed plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  16. Mode of action of cupping--local metabolism and pain thresholds in neck pain patients and healthy subjects.

    Science.gov (United States)

    Emerich, M; Braeunig, M; Clement, H W; Lüdtke, R; Huber, R

    2014-02-01

    Cupping worldwide has been part of traditional medicine systems and is in the western world used as CAM therapy mainly for treating pain syndromes. The mode of action is up to now unclear. In order to investigate its mechanism we measured in parallel metabolic changes in the tissue under the cupping glass and pressure pain thresholds. In 12 volunteers (6 healthy subjects and 6 patients with chronic neck pain) a microdialysis system was implanted subcutaneously on both sides (left and right) above the trapezius muscle. After baseline measures cupping was performed at one randomly selected side (left or right), the other side served as control. Every 20 min during baseline measures and for 280 min after cupping, microdialysis probes for detection of lactate, pyruvate, glucose and glycerin were taken. In addition, pain thresholds were measured before and after cupping with algometry. Cupping resulted in a strong increase of lactate (beginning 160 min after cupping until the end of the measurements) and the lactate/pyruvate ratio, indicating an anaerobe metabolism in the surrounding tissue. Baseline pain thresholds were non-significantly lower in neck pain patients compared to healthy controls and slightly increased immediately after cupping (pcupping in healthy subjects and on the foot in neck pain patients). After 280 min no more significant changes of pain thresholds were detected. Cupping induces >280 min lasting anaerobe metabolism in the subcutaneous tissue and increases immediate pressure pain thresholds in some areas. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    Science.gov (United States)

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  18. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  19. Measuring splash erosion potential under vegetation using sand-filled splash cups

    Science.gov (United States)

    Geißler, C.; Scholten, T.; Kühn, P.

    2009-04-01

    In soil erosion research it is widely accepted that vegetation is not only protecting the soil from the erosive power of rainfall. Under specific circumstances (like they occur e.g. in forests) vegetation can enhance the erosive power of rainfall by modifying its properties (esp. drop size distribution, kinetic energy). The adjacent processes are very complex and variable in time and space and depend on numerous variables (e.g. rainfall intensity, drop size distribution, drop fall velocity, height of the canopy, density of the canopy, crown and leaf traits, LAI). In the last decades a large number of studies focused this process-system using different methods and came to often different results (Brandt 1989; Calder 2001; Foot & Morgan 2005; Hall & Calder 1993; Mosley 1982; Nanko et al. 2006; Park & Cameron 2008; Vis 1986). The main objective of our field experiments in subtropical China is to quantify the modification of precipitation by its pass through the canopy layer for six different tree species, three different successional stages and three different biodiversity classes. For this, new splash cups were developed based on the archetype of Ellison (1947). In contrast to previous studies with splash cups (Vis 1986) or other forms of splash cups (Kinnell 1974; Morgan 1981) we measured the unit sand remaining inside the cup after single natural rainfall events. The new splash cups contain of a PE-flask to which a carrier system has been attached. In this carrier system a cup filled with unit sand of 125-200 µm particle size is inserted. At the bottom of the cup a silk cover is attached to avoid the loss of sand and to guarantee free drainage of water from the cup to the carrier and vice versa. Cup and PE-flask are hydraulically connected by a cotton wick to assure constant moisture content throughout the time of measuring. Additionally, vents in the carrier system ensure that the pressure arising from the insertion of the cup doesn't lead to a loss of sand. The

  20. [One-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage].

    Science.gov (United States)

    Wei, Dan; Wang, Yue; Yuan, Jiabin; Tang, Xiaoming; Zhang, Bin; Lu, Bing; Tan, Bo

    2014-01-01

    To investigate the methods and effectiveness of one-stage operation for pelvis and acetabular fractures combined with Morel-Lavallée injury by internal fixation associated with vacuum sealing drainage (VSD). Between June 2008 and October 2012, 15 cases of pelvis and acetabular fractures combined with Morel-Lavallée injury were treated. There were 5 males and 10 females, aged from 18 to 67 years (mean, 36.8 years). Fractures were caused by traffic accident in 11 cases and crashing injury of heavy object in 4 cases. The time from injury to hospitalization was 3 hours to 9 days (mean, 5.4 days). Morel-Lavallée injury located in the above posterior superior iliac spine in 4 cases, greater trochanter in 7 cases, and anterior proximal thigh in 4 cases. In 10 cases complicated by pelvic fracture, there were 1 case of anteroposterior compression type, 3 cases of lateral compression type, 5 cases of vertical shear type, and 1 case of compound injury type; in 5 cases complicated by acetabular fracture, there were 1 case of transverse fracture, 1 case of posterior wall and posterior column fracture, 1 case of transverse acetabulum plus posterior wall fracture, and 2 cases of both columns fracture. Open reduction and internal fixation were used to treat pelvic and acetabular fractures, and VSD to treat Morel-Lavallée injury. When the drainage volume was less than 20 mL/d, interrupted wound suture or free skin grafting was performed. The hospitalization time was 16-31 days (mean, 20.8 days). Thirteen cases were followed up 4-16 months (mean, 7.8 months). The healing time of Morel-Lavallée injury was 16-36 days after operation (mean, 21.3 days). All the wounds had primary healing, and no infection occurred. The X-ray films showed that all fractures healed, with a mean healing time of 13.6 weeks (range, 11-18 weeks). At 6.5 months after operation, according to Majeed function scoring system in 8 cases of pelvic fracture, the results were excellent in 5 cases, good in 2 cases

  1. Recent advances in uranium exploration with electronic alpha cups

    International Nuclear Information System (INIS)

    Warren, R.K.

    1977-01-01

    Data from a new radon measuring device, based on electronic alpha cups are compared with data from the nonelectronic, plastic alpha cups commonly used in exploring for uranium. A burial time of three days appears to be adequate for the electronic alpha cups to collect exploration data equivalent to those from plastic sensing devices. The advantages of the electronic cups are short time of burial and instant readout in the field; the major disadvantages is the capital expenditure required for the instruments. It is possible the cups may be useful for copper exploration too. 5 refs

  2. The diagnostic accuracy of acetabular labral tears using magnetic resonance imaging and magnetic resonance arthrography: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Toby O. [University of East Anglia, Faculty of Health, Queen' s Building, Norwich (United Kingdom); Hilton, Gemma [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P.; Donell, Simon T. [Norfolk and Norwich University Hospital, University of East Anglia, Norwich (United Kingdom); Hing, Caroline B. [St. George' s Hospital, London (United Kingdom)

    2011-04-15

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have been advocated for the diagnosis of acetabular labral tears. The purpose of this study was to determine the sensitivity and specificity of MRI and MRA in diagnosing acetabular labral tears using meta-analysis. Pertinent published and unpublished literature databases were reviewed. A two-by-two table was constructed to calculate the sensitivity and specificity of MRI or MRA investigations against surgical outcomes. Pooled sensitivity and specificity and Receiver Operating Characteristic curve (ROC) evaluations were performed. Methodological quality of each study was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) tool. Nineteen papers assessing 881 hips were reviewed. Conventional MRI was assessed in 13 studies and MRA was assessed in 16 studies. Whilst both MRI (0.5-3T) and MRA (0.5-3T) presented with a moderate sensitivity and specificity (sensitivity 66%, 87%; specificity 79%, 64%), diagnostic accuracy of MRA appeared to be superior to MRI in detecting acetabular labral tears on ROC curve interpretation. The literature poorly described population characteristics, assessor blinding, with limited sample sizes. MRI and MRA may be useful adjuncts in the diagnosis of acetabular labral tears in adults. MRA appears to be superior to conventional MRI. (orig.)

  3. A critical comparison of ten disposable cup LCAs

    Energy Technology Data Exchange (ETDEWEB)

    Harst, Eugenie van der, E-mail: eugenie.vanderharst@wur.nl [Environmental Systems Analysis Group, Wageningen University, P.O. Box 47, NL-6700 AA Wageningen (Netherlands); Potting, José, E-mail: jose.potting@wur.nl [Environmental Systems Analysis Group, Wageningen University, P.O. Box 47, NL-6700 AA Wageningen (Netherlands); Environmental Strategies Research (fms), KTH Royal Institute of Technology, SE-110 44 Stockholm (Sweden)

    2013-11-15

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches.

  4. Prevalence of disc cupping in non-glaucomatous eyes

    Directory of Open Access Journals (Sweden)

    José Pablo Chiappe

    2015-02-01

    Full Text Available This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter 1.5 times (respectively the diameter of the ophthalmoscope's selected light spot on the posterior pole. The cupping was classified as the ratio of the vertical cupping diameter and the vertical disc diameter on a relative decimal scale from 0.0 to 1.0.This study included 184 subjects with a mean age of 40.5 ± 9.5 years; 149 (81% were males. Their mean ocular pressure was 12.4 ± 1.5 mmHg (range 10-17 mmHg. There was a high correlation between optic disc sizes and cupping in the right and left eyes (Pearson Correlation r = 0.866, p < 0.001; therefore, for simplicity only the data for right eyes are presented. According to our definition, the optic discs in these eyes comprised 27 (14.7% small, 141 (76.6% medium and 16 (8.7% large. The small optic discs were rarely cupped, and the large optic discs were always cupped. Optic disc cupping greater than 0.7 was rarely found and should be suspect of glaucoma. Clinical doctors should be aware of this and refer those subjects with abnormal cupping to the specialist.

  5. A critical comparison of ten disposable cup LCAs

    International Nuclear Information System (INIS)

    Harst, Eugenie van der; Potting, José

    2013-01-01

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have only one impact category in common, namely climate change with global warming potential (GWP) as its category indicator. Quantitative GWP results of the studies were closer examined. GWPs within and across each study show none of the cup materials to be consistently better than the others. Comparison of the absolute GWPs (after correction for the cup volume) also shows no consistent better or worse cup material. An evaluation of the methodological choices and the data sets used in the studies revealed their influence on the GWP. The differences in GWP can be attributed to a multitude of factors, i.e., cup material and weight, production processes, waste processes, allocation options, and data used. These factors basically represent different types of uncertainty. Sensitivity and scenario analyses provided only the influence of one factor at once. A systematic and simultaneous use of sensitivity and scenario analyses could, in a next research, result in more robust outcomes. -- Highlights: • Conflicting results from life cycle assessment (LCA) on disposable cups • GWP results of LCAs did not point to a best or worst cup material. • Differences in GWP results are due to methodological choices and data sets used. • Standardized LCA: transparency of LCA studies, but still different in approaches

  6. Bipolar hip arthroplasty for avascular necrosis of femoral head in young adults

    Science.gov (United States)

    Dudani, Baldev; Shyam, Ashok K; Arora, Pankush; Veigus, Arjun

    2015-01-01

    Background: Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. Materials and Methods: The current study retrospectively evaluated patients’records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. Results: The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. Conclusion: Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage. PMID:26015634

  7. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up: Short title: Ossis custom 3D-Printed tri-flanged acetabular implant.

    Science.gov (United States)

    Kieser, David C; Ailabouni, Ramez; Kieser, Sandra C J; Wyatt, Michael C; Armour, Paul C; Coates, Mark H; Hooper, Gary J

    2018-05-01

    Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.

  8. Accumulation of radon in the underground detector cups

    International Nuclear Information System (INIS)

    Qiu Yuanhuo.

    1985-01-01

    Theoretical calculations based on the radon migration mechanism (i. e. diffusion, convection and atmospheric pumping etc) show that the balance of radon concentration in underground detector cups buried and in surrounding soil gas requires about 0.7-10 hours. However, the equilibrium of radon with its daughter products in the cups needs about 4 hours. Therefore, it is considered that 4.5-12 hours are needed for these two processes. It takes 3-4 days for Tn to reach radioactive equilibrium with its short-lived daughter products. When thorium concentration is higher than background exposure time of the detector cups should be over 3-4 days. Using buried detector cups, field experiments give correlative results compared with those of theoretical calculations. The study is oriented both for optimizing the burial time of the detector cup and interpretation of radon anomalies detected

  9. Distance constant of the Risø cup anemometer

    DEFF Research Database (Denmark)

    Kristensen, L.; Frost Hansen, O.

    2002-01-01

    The theory for cup-anemometer dynamics is presented in some detail and two methods of obtaining the distance constant lo are discussed. The first method is based on wind tunnel measurements: with a constant wind speed the cup anemometer is released from alocked position of the rotor...... and the increasing rotation rate recorded. It is concluded that the rapid increase in rotation rate makes the method very inaccurate. The second method consists of an analysis of turbulent, atmospheric of wind speed asmeasured by the cup anemometer and a fast-responding sonic anemometer with a spatial eddy...... resolution which is significantly better than that which can be obtained by a cup anemometer. The ratio between the measured power spectra of the horizontal windspeed by the two instruments contains the necessary information for determining the response characteristics of the cup anemometer and thereby lo...

  10. Bone remodeling around cementless tantalum cups

    NARCIS (Netherlands)

    Grillo, J. -C.; Flecher, X.; Bouvenot, J.; Argenson, J. -N.

    2008-01-01

    Purpose of the study.-Most studies have reported a significant decrease in periacetabular bone stock one year after implantation of a cementless cup. The purpose of this work was to study the bone-implant interface of the tantalum cup using plain X-rays and dual-energy X-ray absorptiometry (DEXA).

  11. High resolution X-ray imaging of bone-implant interface by large area flat-panel detector

    International Nuclear Information System (INIS)

    Kytyr, D; Jirousek, O; Dammer, J

    2011-01-01

    The aim of the research was to investigate the cemented bone-implant interface behavior (cement layer degradation and bone-cement interface debonding) with emphasis on imaging techniques suitable to detect the early defects in the cement layer. To simulate in vivo conditions a human pelvic bone was implanted with polyurethane acetabular cup using commercial acrylic bone cement. The implanted cup was then loaded in a custom hip simulator to initiate fatigue crack propagation in the bone cement. The pelvic bone was then repetitively scanned in a micro-tomography device. Reconstructed tomography images showed failure processes that occurred in the cement layer during the first 250,000 cycles. A failure in cemented acetabular implant - debonding, crumbling and smeared cracks - has been found to be at the bone-cement interface. Use of micro-focus source and high resolution flat panel detector of large physical dimensions allowed to reconstruct the micro-structural models suitable for investigation of migration, micro-motions and consecutive loosening of the implant. The large area flat panel detector with physical dimensions 120 x 120mm with 50μm pixel size provided a superior image quality compared to clinical CT systems with 300-150μm pixel size.

  12. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    Science.gov (United States)

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Absence or interruption of the supra-acetabular line: a subtle plain film indicator of hip pathology

    International Nuclear Information System (INIS)

    Major, N.M.; Helms, C.A.

    1996-01-01

    Objective. To show that absence or interruption of the supraacetabular line is a subtle plain film indicator of pathology in the acetabulum. Design. Nineteen hips from 17 patients with known disease processes involving the acetabulum as demonstrated by subsequent magnetic resonance imaging, bone scan or plain film follow-up were evaluated with antero-posterior (AP) plain films of the pelvis. Three additional cases were diagnosed prospectively using interruption of the supra-acetabular line as the criterion for inclusion. Fifty AP plain films of the pelvis in patients without hip pain were examined prospectively to determine normal imaging criteria. Results and conclusions. The normal supra-acetabular line measures 2-3 mm in thickness superiorly and is a thin sclerotic line in the medial aspect. In all 22 hips (with pathology) in this series, the line was interrupted or absent. Loss or interruption of the supra-acetabular line may thus be a subtle pain film indicator of a disease process involving the acetabulum. This plain film sign has not previously been reported. (orig.). With 8 figs., 1 tab

  14. Rapid Hip Osteoarthritis Development in a Patient with Anterior Acetabular Cyst with Sagittal Alignment Change

    Directory of Open Access Journals (Sweden)

    Yasuhiro Homma

    2014-01-01

    Full Text Available Rapidly destructive coxarthrosis (RDC is rare and develops unusual clinical course. Recent studies suggest multiple possible mechanisms of the development of RDC. However the exact mechanism of RDC is still not clear. The difficulty of the study on RDC is attributed to its rareness and the fact that the data before the onset of RDC is normally unavailable. In this report, we presented the patient having the radiographic data before the onset who had rapid osteoarthritis (OA development after contralateral THA, which meets the current criteria of RDC. We thought that the increased posterior tilt of the pelvis after THA reinforced the stress concentration at pre-existed anterior acetabular cyst, thereby the destruction of the cyst was occurred. As a result the rapid OA was developed. We think that there is the case of rapid osteoarthritis developing due to alternating load concentration by posterior pelvic tilt on preexisting anterior acetabular cyst such as our patient among the cases diagnosed as RDC without any identifiable etiology. The recognition of sagittal alignment changes and anterior acetabular cyst may play important role in prediction and prevention of the rapid hip osteoarthritis development similar to RDC.

  15. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Acetabular osteotomy for double boarding in lateral decubitus. Anatomical bases and surgical technique

    International Nuclear Information System (INIS)

    Lazennec, J Y; Del Vecchio, R; Saillant, G

    2001-01-01

    The periacetabular osteotomies of reorientation of the eotilo have a reputation of being difficult from the technical point of view. The authors present a technique of juxta acetabular osteotomy that respects the posterior column of the acetabulo the same as the GANZ technique. The osteotomy is of simpler realization thanks to an installation that allows carrying out two simultaneous boarding. The osteotomy lines, their rectilinear and controllable in permanency through of images intensificator and they don't constitute any risk for the essential vascular contribution of the obturatriz artery and their branches. Their other interest comes represented by the possibility of correcting easily the parasitic retroversion associated to the descent of the whole eotilo, that it allows to avoid the bad positions that they affect the center of the articulation and the widths acetabular

  17. Should total hip arthroplasty be performed acutely in the treatment of acetabular fractures in elderly or used as a salvage procedure only?

    Directory of Open Access Journals (Sweden)

    Katharine Hamlin

    2017-01-01

    Full Text Available Background: Total hip arthroplasty (THA is now an increasingly common procedure for people sustaining acetabular fractures. The incidence of acetabular fractures among the elderly population is increasing, and contemporary treatment aims to avoid the risks of prolonged incumbency associated with poor bone stock for fixation or inability to comply with limited weightbearing in this patient group. The concept of acute hip arthroplasty as a treatment for acetabular fracture is, therefore, becoming more topical and relevant. Our systematic review investigates whether THAs for acetabular fractures should be performed acutely, with a short delay, or as a late procedure for posttraumatic osteoarthritis (PTOA if it develops. Materials and Methods: Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines were followed when undertaking this systematic review. Detailed searches were performed on three different databases, using keywords, such as “acetabular fracture,” “acetabular trauma,” “total hip arthroplasty,” “hip arthroplasty,” and “hip prosthesis.” Studies from 1975 to September 2016 were included in the study. All studies included in the review were independently critically appraised by two of the authors. Results: Forty three studies were included in this review. Only two of them actually compared acute and delayed THAs for acetabular fractures with the rest focusing on one or the other. Results were comparable between acute and late THAs in terms of aseptic loosening, operative time, blood loss, Harris Hip Score, and ability to mobilize postoperatively without aid. Complication rates, however, were much higher in the acute group. Conclusion: Evidence based on this topic is scarce and therefore we have to be cautious about drawing a definitive conclusion. The findings of this systematic review do suggest, however, that acute THAs should be considered in elderly patients, where fixation is not possible, or

  18. Corrosion Behavior of Ceramic Cup of Blast Furnace Hearth by Liquid Iron and Slag

    Science.gov (United States)

    Li, Yanglong; Cheng, Shusen; Wang, Zhifeng

    2016-10-01

    Three kinds of sample bricks of ceramic cups for blast furnace hearth were studied by dynamic corrosion tests based on different corrosion systems, i.e., liquid iron system, liquid slag system and liquid iron-slag system. Considering the influence of temperature and sample rotational speed, the corrosion profiles and mass loss of the samples were analyzed. In addition, the microstructure of the corroded samples was observed by optical microscope (OM) and scanning electron microscope (SEM). It was found that the corrosion profiles could be divided into iron corrosion region, slag corrosion region and iron-slag corrosion region via corrosion degree after iron-slag corrosion experiment. The most serious corrosion occurred in iron-slag corrosion region. This is due to Marangoni effect, which promotes a slag film formed between liquid iron and ceramic cup and results in local corrosion. The corrosion of the samples deepened with increasing temperature of liquid iron and slag from 1,623 K to 1,823 K. The variation of slag composition had greater influence on the erosion degree than that of rotational speed in this experiment. Taking these results into account the ceramic cup composition should be close to slag composition to decrease the chemical reaction. A microporous and strong material should be applied for ceramic cup.

  19. Revisión acetabular con conservación del componente metálico osteointegrado y cementado de un componente de poliestireno. Reporte de una serie de 40 casos. [Acetabular revision cementing a liner into a stable acetabular shell

    Directory of Open Access Journals (Sweden)

    Fernando Manuel Bidolegui

    2013-12-01

    Full Text Available In­tro­duc­ción: Un escenario cada vez más frecuente en la cirugía de revisión protésica de la cadera es hallar un cotilo no cementado fijo con una falla del componente modular de polietileno. Una completa revisión acetabular se presenta como demasiado agresiva cuando el componente metálico es salvable. Cementar un nuevo inserto de polietileno dentro del componente acetabular metálico os-teointegrado es una alternativa. Comunicamos los resultados con esta técnica, y sus indicaciones, el modo de realización y las posibles limitaciones. Materiales­y­Métodos: Entre 2001 y 2011, se cementaron 40 componentes de polietileno dentro de copas no cementadas. Se evaluó radiológicamente y clínicamente a todos los pacientes. El motivo por el que se cementó un inserto fue falla o rotura de mecanismo de captura (11 casos; 27,5%, ganar estabilidad (18 casos; 45% y falta de disponibilidad del inserto correspondiente (11 casos, 27,5%. Resultados:­ La tasa de duración del implante sin reoperación a 46 meses de seguimiento fue del 92%. Un paciente (2,4% sufrió una infección, y dos presentaron inestabilidad (4,8%. No se presentaron aflojamientos hasta el último seguimiento. El puntaje preoperatorio y posoperatorio en la escala de Harris fue de 59 y 80, respectivamente. Conclusiones: Los datos técnicos por considerar para tener éxito son: utilizar un inserto de menor tamaño que el de la copa, cementar insertos texturizados y dejar siempre como mínimo un manto de cemento uniforme de 2 mm. Nuestros resultados preliminares cementando un inserto de polietileno dentro de una copa acetabular osteointegrada parecerían justificar esta técnica de revisión en pos de prevenir la pérdida de capital óseo asociada a la necesidad de recambio de copas osteointegradas.

  20. Preparation of leukocyte-poor platelet concentrates from buffy coats. I. Special inserts for centrifuge cups

    NARCIS (Netherlands)

    Pietersz, R. N.; Reesink, H. W.; Dekker, W. J.; Fijen, F. J.

    1987-01-01

    A special insert was developed for centrifuge cups in order to prepare leukocyte-poor platelet concentrates from buffy coats by using quadruple citrate phosphate dextrose-saline adenine glucose mannitol systems from different manufacturers. Each centrifuge cup could contain up to 4 sets of double

  1. The crescent sign: dissociation of the polyethylene liner from a modular acetabular component in total hip arthroplasty

    International Nuclear Information System (INIS)

    White, S.P.; Blom, A.W.; Lee, M.; Smith, E.J.

    2005-01-01

    To study whether there was a common pattern of clinical symptoms, signs and radiographic features for the dissociation of the polyethylene liner from an acetabular component and to postulate reasons for these features. Retrospective study of notes and radiographs of cases of revision hip arthroplasty for polyethylene liner dissociation of the cementless Harris-Galante I porous-coated acetabular component (Zimmer Inc, Warsaw, IN) at the Avon Orthopaedic Centre, Bristol, UK and St. Mary's Hospital, Bristol, UK between 1995 and 2004. Patients were contacted to confirm preoperative symptoms. Nine cases of late polyethylene liner dissociation of this prosthesis have been revised in these institutions. All patients presented with a reduction in mobility, groin pain and limp. Eight patients reported an audible noise on hip movement. In all cases, radiographs showed radiolucency medial to the femoral neck in association with an eccentrically placed femoral head showing contact with the acetabular metal shell, which we have termed the ''crescent sign.'' There is a typical clinical presentation in this study. The diagnosis can be made from a single anteroposterior pelvic radiograph without the need for previous films for comparison, or the need for arthrography. Clinicians should look specifically for the crescent sign when an eccentrically placed femoral head has been noted, in order to differentiate the more unusual diagnosis of dissociation from that of polyethylene wear. Early revision surgery can prevent damage to the femoral head and metal acetabular shell, thus reducing the complexity of revision surgery. (orig.)

  2. Difficult acetabular revision. A preliminary report.

    Science.gov (United States)

    Newport, M L; Stuchin, S A; Frankel, V H; Zuckerman, J

    1986-01-01

    Thirteen patients (14 hips) underwent revision from conventional cemented total hip arthroplasty to uncemented acetabular threaded screw-in components and cementless femoral press-fit stems by means of the Autophor, Biofit, and Ti-Thread designs. The patients suffered from all forms of primary hip disease except rheumatoid arthritis; their average age was 34 years. The average preoperative Harris hip score was 39.4; the average postoperative score was 71.2 at six months, 90.6 at one year, and 91.6 at two years. Complications included two femoral shaft fractures, one femoral nerve palsy, and one dislocation. No signs have been observed of loosening or migration as of an early (6-24 months) follow-up.

  3. World Cup Cities Project: movement by the sport legacy of sporting mega events

    Directory of Open Access Journals (Sweden)

    Rodrigo Pojar Paiva

    2013-11-01

    Full Text Available The achievement of sporting mega events is configured as an exceptional opportunity for the promotion of sports in the host cities. For this positive legacy to happen it must be previously planned, executed and monitored. This study aimed to present the national structure of the World Cup Cities Project and analyse the results obtained in six host cities of the FIFA World Cup 2014. The results showed that the social and sports legacy was not planned by public managers and there are no systems of control and evaluation of sport in any of the host cities, until the realization of the project World Cup Cities.

  4. Splash-cup plants accelerate raindrops to disperse seeds

    Science.gov (United States)

    Amador, Guillermo J.; Yamada, Yasukuni; McCurley, Matthew; Hu, David L.

    2013-01-01

    The conical flowers of splash-cup plants Chrysosplenium and Mazus catch raindrops opportunistically, exploiting the subsequent splash to disperse their seeds. In this combined experimental and theoretical study, we elucidate their mechanism for maximizing dispersal distance. We fabricate conical plant mimics using three-dimensional printing, and use high-speed video to visualize splash profiles and seed travel distance. Drop impacts that strike the cup off-centre achieve the largest dispersal distances of up to 1 m. Such distances are achieved because splash speeds are three to five times faster than incoming drop speeds, and so faster than the traditionally studied splashes occurring upon horizontal surfaces. This anomalous splash speed is because of the superposition of two components of momentum, one associated with a component of the drop's motion parallel to the splash-cup surface, and the other associated with film spreading induced by impact with the splash-cup. Our model incorporating these effects predicts the observed dispersal distance within 6–18% error. According to our experiments, the optimal cone angle for the splash-cup is 40°, a value consistent with the average of five species of splash-cup plants. This optimal angle arises from the competing effects of velocity amplification and projectile launching angle. PMID:23235266

  5. Clad vent set cup closure-weld-zone grinding evaluation

    International Nuclear Information System (INIS)

    Ulrich, G.B.; Woods, A.T.; Ohriner, E.K.

    1996-04-01

    Clad vent set (CVS) cups were ground in the closure-weld zone to reduce the wall-thickness variation created by the cup deep-drawing process. A significantly more uniform wall thickness would be beneficial for the CVS closure-weld operation. The goal was to reduce the average within-cup wall-thickness variation (defined as the range of wall thicknesses in the closure-weld zone) approximately 50% from the Cassini production value of 42 microm. This goal was shown to be achievable but, unfortunately, not with the existing blank and formed cup thicknesses

  6. [Study on standardization of cupping technique: elucidation on the establishment of the National Standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping].

    Science.gov (United States)

    Gao, Shu-zhong; Liu, Bing

    2010-02-01

    From the aspects of basis, technique descriptions, core contents, problems and solutions, and standard thinking in standard setting process, this paper states experiences in the establishment of the national standard Standardized Manipulation of Acupuncture and Moxibustion, Part V, Cupping, focusing on methodologies used in cupping standard setting process, the method selection and operating instructions of cupping standardization, and the characteristics of standard TCM. In addition, this paper states the scope of application, and precautions for this cupping standardization. This paper also explaines tentative ideas on the research of standardized manipulation of acupuncture and moxibustion.

  7. T2* Mapping Provides Information That Is Statistically Comparable to an Arthroscopic Evaluation of Acetabular Cartilage.

    Science.gov (United States)

    Morgan, Patrick; Nissi, Mikko J; Hughes, John; Mortazavi, Shabnam; Ellerman, Jutta

    2017-07-01

    Objectives The purpose of this study was to validate T2* mapping as an objective, noninvasive method for the prediction of acetabular cartilage damage. Methods This is the second step in the validation of T2*. In a previous study, we established a quantitative predictive model for identifying and grading acetabular cartilage damage. In this study, the model was applied to a second cohort of 27 consecutive hips to validate the model. A clinical 3.0-T imaging protocol with T2* mapping was used. Acetabular regions of interest (ROI) were identified on magnetic resonance and graded using the previously established model. Each ROI was then graded in a blinded fashion by arthroscopy. Accurate surgical location of ROIs was facilitated with a 2-dimensional map projection of the acetabulum. A total of 459 ROIs were studied. Results When T2* mapping and arthroscopic assessment were compared, 82% of ROIs were within 1 Beck group (of a total 6 possible) and 32% of ROIs were classified identically. Disease prediction based on receiver operating characteristic curve analysis demonstrated a sensitivity of 0.713 and a specificity of 0.804. Model stability evaluation required no significant changes to the predictive model produced in the initial study. Conclusions These results validate that T2* mapping provides statistically comparable information regarding acetabular cartilage when compared to arthroscopy. In contrast to arthroscopy, T2* mapping is quantitative, noninvasive, and can be used in follow-up. Unlike research quantitative magnetic resonance protocols, T2* takes little time and does not require a contrast agent. This may facilitate its use in the clinical sphere.

  8. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    Science.gov (United States)

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  9. Orienteering World Cup hosted by CERN Club

    CERN Multimedia

    Katarina Anthony

    2010-01-01

    Elite runners took to the streets of Geneva for the last leg of the Orienteering World Cup, from 8-10 October. The Geneva finals were hosted by the CERN Orienteering Club and concluded months of competitions held across 5 countries.   Women's World-Cup winner, Simone Niggli (centre).  © Ilknur Colak The final events of the Orienteering World Cup took place in the Old Town of Geneva and Saint-Cergue, with runners following routes prepared by the CERN Orienteering Club. Orienteering is a sport of navigation, using only a compass, map and your sense of direction. The objective is to get to all the points on the map as quickly as possible, choosing your own paths as you run. This was the CERN club’s first successful participation in the World Cup, cementing its reputation as a fixture in the international orienteering world. Orienteering is not your typical Swiss pastime. Developed in Scandinavia, the sport has been gaining popularity internationally. “...

  10. Cup products in Hopf cyclic cohomology with coefficients in contramodules

    OpenAIRE

    Rangipour, Bahram

    2010-01-01

    We use stable anti Yetter-Drinfeld contramodules to improve the cup products in Hopf cyclic cohomology. The improvement fixes the lack of functoriality of the cup products previously defined and show that the cup products are sensitive to the coefficients.

  11. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.; Seidman, D.N.

    1977-01-01

    A novel Faraday cup is described which allows the simultaneous observation and measurement of ion-beam currents. The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA), which serves as the basis of an internal image intensification system (a gain of >10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion current which is measured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30-keV Ar + ion beam is presented as an illustrative example. We have also employed this Faraday cup to observe and measure 30-keV Cr + , Mo + , or W + , and 18-keV Au + ion beams employed for the in situ irradiation of field-ion microscope specimens

  12. Lumbosacral plexopathies associated with acetabular fracture

    Directory of Open Access Journals (Sweden)

    Patpiya Sirasaporn

    2017-01-01

    Full Text Available Lumbosacral plexopathies are of considerably less epidemiologic common prevalence than brachial plexus. The most common form of trauma resulting in lesions affecting the lumbosacral plexus is injuries to sacroiliac region. The symptoms which are caused by compressing lumbosacral plexus are sensory disturbance and weakness in an affected leg. The author reports a case of a 65-year-old male with a history of right acetabular fracture status post open reduction and internal fixation by plate and screw who complained weakness and numbness in the right leg. Four months later, he still had difficulty in walking and felt paresthesia at the right lateral thigh and entire of the right foot. His further investigation which was electrodiagnostic study was diagnosed as right lumbosacral plexopathies.

  13. Modified Faraday cup

    Science.gov (United States)

    Elmer, John W.; Teruya, Alan T.; O'Brien, Dennis W.

    1996-01-01

    A tomographic technique for measuring the current density distribution in electron beams using electron beam profile data acquired from a modified Faraday cup to create an image of the current density in high and low power beams. The modified Faraday cup includes a narrow slit and is rotated by a stepper motor and can be moved in the x, y and z directions. The beam is swept across the slit perpendicular thereto and controlled by deflection coils, and the slit rotated such that waveforms are taken every few degrees form 0.degree. to 360.degree. and the waveforms are recorded by a digitizing storage oscilloscope. Two-din-tensional and three-dimensional images of the current density distribution in the beam can be reconstructed by computer tomography from this information, providing quantitative information about the beam focus and alignment.

  14. Soccer jersey sponsors and the world cup

    NARCIS (Netherlands)

    Groot, L.F.M.; Ferwerda, J.

    2014-01-01

    The market for soccer jerseys is a multibillion market dominated by Adidas, Nike and Puma. This paper investigates whether jersey sponsorship has a non-arbitrary effect on the outcomes of World Cup knockout matches. The results show that in the knockout stages of the last four World Cup tournaments,

  15. Nuclear fuel element nut retainer cup

    International Nuclear Information System (INIS)

    Walton, L.A.

    1977-01-01

    A typical embodiment has an end fitting for a nuclear reactor fuel element that is joined to the control rod guide tubes by means of a nut plate assembly. The nut plate assembly has an array of nuts, each engaging the respective threaded end of the control rod guide tubes. The nuts, moreover, are retained on the plate during handling and before fuel element assembly by means of hollow cylindrical locking cups that are brazed to the plate and loosely circumscribe the individual enclosed nuts. After the nuts are threaded onto the respective guide tube ends, the locking cups are partially deformed to prevent one or more of the nuts from working loose during reactor operation. The locking cups also prevent loose or broken end fitting parts from becoming entrained in the reactor coolant

  16. Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

    Science.gov (United States)

    Assi, Chahine; El-Najjar, Elie; Samaha, Camille; Yammine, Kaissar

    2017-03-01

    Dual mobility cups (DMC) in total hip arthroplasty (THA) are becoming popular among orthopaedic surgeons. Substantial benefit of their use has been reported among high risk patients, particularly in reducing post-operative hip instability (dislocation). Many reports stated some concern when implanted in young and active people where complications such as polyethylene wear and mechanical loosening could potentially be higher. This Middle Eastern study analyses a retrospective series of THA for any aetiology other than infection, using DMC for the acetabular component in 75 patients (85 implants) less than 70 years old. No instability, intra-prosthetic dislocation or mechanical failure was reported during a mean follow-up of five years. The only major complication was a post-operative infection. The mean post- operative modified Harris hip score was 97.1 out of 100. All patients resumed their daily activities and all religious practicing patients were able to accomplish their prayer positions without pain. DMC is found to be an interesting option in reducing dislocation events in young patients. Those excellent short-term results would encourage surgeons to use DMC in an active and highly demanding population. Further research is necessary to confirm maintenance of such results at long term follow-up.

  17. Examination and treatment of a professional ballet dancer with a suspected acetabular labral tear: A case report.

    Science.gov (United States)

    Khoo-Summers, Lynnette; Bloom, Nancy J

    2015-08-01

    Dancers are at risk for developing groin pain that is due to acetabular labral tears. Although surgical management of labral tears has been reported extensively, conservative management has been poorly described. This case report describes the examination, diagnosis, and treatment of groin pain in a professional ballet dancer with a suspected acetabular labral tear. Treatment focused on decreasing anterior hip joint stresses and improving the precision of hip motion through correction of alignment and movement impairments noted during functional activities and dance. Successful outcomes included a reduction in pain and return to professional ballet dancing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A Zero-Gravity Cup for Drinking Beverages in Microgravity

    Science.gov (United States)

    Pettit, Donald R.; Weislogel, Mark; Concus, Paul; Finn, Robert

    2011-01-01

    To date, the method for astronauts to drink liquids in microgravity or weightless environments is to suck the liquid from a bag or pouch through a straw. A new beverage cup works in microgravity and allows astronauts to drink liquids from a cup in a manner consistent with that on Earth. The cup is capable of holding beverages with an angled channel running along the wall from the bottom to the lip. In microgravity, a beverage is placed into the cup using the galley dispenser. The angled channel acts as an open passage that contains only two sides where capillary forces move the liquid along the channel until it reaches the top lip where the forces reach an equilibrium and the flow stops. When one sips the liquid at the lip of the channel, the capillary force equilibrium is upset and more liquid flows to the lip from the reservoir at the bottom to re-establish the equilibrium. This sipping process can continue until the total liquid contents of the cup is consumed, leaving only a few residual drops about the same quantity as in a ceramic cup when it is drunk dry on Earth.

  19. Telecommunications, power supply, computer systems: the infrastructures of the soccer world cup; Telecommunications, electricite, informatique: les infrastructures de la Coupe du Monde

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-06-01

    The 1998 edition of the soccer world cup took place in ten different stadiums in France and several related sites. This short paper gives a general overview of the infrastructures developed for this occasion in the domains of telecommunications, power supply (substations, protection systems, computerized control systems..), and computer systems. (J.S.)

  20. Danish survey of acetabular component positioning practice during primary total hip arthroplasty

    DEFF Research Database (Denmark)

    Cotong, Dana; Troelsen, Anders; Husted, Henrik

    2017-01-01

    questions on optimal component positioning, surgical practice patterns in primary THA, indications and surgical techniques used in revision THA. RESULTS: A total of 42 questionnaires were collected, two were excluded, leaving 40 for analyses. 97% of the surgeons reported an optimum cup anteversion within...... the Lewinnek and Callanan "safe zones", whereas 97% and 83% reported optimum cup inclination within the Lewinnek and Callanan "safe zones", respectively. The reported range for optimal cup positioning varied from 30-55 degrees of inclination and 15-30 degrees of anteversion. The minimum and max-imum accepted...

  1. Acetabular labral tears with underlying chondromalacia: a possible association with high-level running.

    Science.gov (United States)

    Guanche, Carlos A; Sikka, Robby S

    2005-05-01

    The use of hip arthroscopy has helped delineate intra-articular pathology and has enabled clinicians to further elucidate the factors responsible for injuries, such as running. The subtle development of degenerative changes may be a result of repetitive impact loading associated with this sport. This study presents a population of runners with common pathologic acetabular changes. Case series. Eight high-level runners with an average age of 36 years (range, 19 to 45 years) were seen for complaints of increasing hip pain with running without any history of macrotrauma. All of the patients had either run several marathons (4), were triathletes (1), Olympic middle distance runners (1), or had run more than 10 miles per week for longer than 5 years (2). Plain radiographic analysis revealed no degenerative changes and an average center-edge (CE) angle of 36.7 degrees (range, 28 degrees to 44 degrees). All patients underwent hip arthroscopy with labral debridement. In 6 patients (75%), a chondral injury of the acetabular cartilage underlying the labral tear was noted. In addition, 3 patients had ligamentum teres disruptions. It is possible that the development of these tears is the result of subtle instability, which may be exacerbated by running, eventually leading to labral tearing and possible ligamentum teres disruption. While perhaps concurrently, subtle acetabular dysplasia may play a role. Although this study does not confirm an association between running and the development of labral tears or chondral lesions in the hip, it certainly questions whether there is an injury pattern common to this population, a "runner's hip." Level IV.

  2. Periacetabular Bone Mineral Density Changes After Resurfacing Hip Arthroplasty Versus Conventional Total Hip Arthroplasty. A Randomized Controlled DEXA Study

    NARCIS (Netherlands)

    Smolders, J.M.H.; Pakvis, D.F.; Hendrickx, B.W.; Verdonschot, Nicolaas Jacobus Joseph; van Susante, J.L.C.

    2013-01-01

    A randomized controlled trial was performed to evaluate acetabular bone mineral density (BMD) changes after hip resurfacing (RHA) versus an established conventional total hip arthroplasty (THA). A total of 71 patients were allocated randomly to receive either an RHA press-fit cobalt–chromium cup (n

  3. Microindentation hardness evaluation of iridium alloy clad vent set cups

    International Nuclear Information System (INIS)

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1993-01-01

    An iridium alloy, DOP-26, is used as cladding for 238 PuO 2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors

  4. Microindentation hardness evaluation of iridium alloy clad vent set cups

    International Nuclear Information System (INIS)

    Ulrich, G.B.; DeRoos, L.F.; Stinnette, S.E.

    1992-01-01

    An iridium alloy, DOP-26, is used as cladding for 238 PuO 2 fuel in radioisotope heat sources for space power systems. Presently, DOP-26 iridium alloy clad vent sets (CVS) are being manufactured at the Oak Ridge Y-12 Plant for potential use in the National Aeronautics and Space Administration's Cassini mission to Saturn. Wrought/ground/stress relieved blanks are warm formed into CVS cups. These cups are then annealed to recrystallize the material for subsequent fabrication/assembly operations as well as for final use. One of the cup manufacturing certification requirements is to test for Vickers microindentation hardness. New microindentation hardness specification limits, 210 to 310 HV, have been established for a test load of 1000 grams-force (gf). The original specification limits, 250 to 350 HV, were for 200 gf testing. The primary reason for switching to a higher test load was to reduce variability in the test data. The DOP-26 alloy exhibits microindentation hardness load dependence, therefore, new limits were needed for 1000 gf testing. The new limits were established by testing material from 15 CVS cups using 200 gf and 1000 gf loads and then statistically analyzing the data. Additional work using a Knoop indenter and a 10 gf load indicated that the DOP-26 alloy grain boundaries have higher hardnesses than the grain interiors

  5. Classification of operational characteristics of commercial cup-anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T; Schmidt Paulsen, U [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1999-03-01

    The present classification of cup-anemometers is based on a procedure for classification of operational characteristics of cup-anemometers that was proposed at the EWEC `97 conference in Dublin 1997. Three definitions of wind speed are considered. The average longitudinal wind speed (ID), the average horizontal wind speed (2D) and the average vector wind speed (3D). The classification is provided in these terms, and additionally, the turbulence intensities, which are defined from the same wind speed definitions. The commercial cup-anemometers have all been calibrated in wind tunnel for the normal calibrations and angular characteristics. Friction was measured by blywheel testing, where the surrounding temperatures were varied over a wide range. The characteristics of the cup-anemometers have been fitted to the heuristic dynamic model, and the response has been calculated in time domain for prescribed ranges of external operational conditions. The results are presented in ranges of maximum deviations of `measured` average wind speed. For each definition of wind speed and turbulence intensity, the cup-anemometers are ranked according to the most precise instrument. Finally, the most important systematic error sources are commented. (au)

  6. Can a cup anemometer 'underspeed'? A heretical question

    DEFF Research Database (Denmark)

    Kristensen, L.

    2002-01-01

    An analysis of cup-anemometer dynamics has been carried out in order to determine whether the mean-wind velocity can have a negative bias. This would be contrary to the general belief that cup anemometers always overspeed. Compared to prior analyses, the effect of a possible nonlinearity...... of the calibration function is included. The conclusion is that neither longitudinal nor lateral velocity fluctuations can contribute significantly to a negative bias. However, if a cup anemometer has an angular response that falls below the ideal cosine response, there will, as demonstrated in the concluding...... discussion, be a negative contribution from the vertical velocity fluctuations to the total bias, and this contribution may even outbalance the positive contributions from the longitudinal velocity fluctuations. Concrete evidence of such exotic cup anemometer behaviour has not been reported in the literature....

  7. Prediction of specialty coffee cup quality based on near infrared spectra of green coffee beans.

    Science.gov (United States)

    Tolessa, Kassaye; Rademaker, Michael; De Baets, Bernard; Boeckx, Pascal

    2016-04-01

    The growing global demand for specialty coffee increases the need for improved coffee quality assessment methods. Green bean coffee quality analysis is usually carried out by physical (e.g. black beans, immature beans) and cup quality (e.g. acidity, flavour) evaluation. However, these evaluation methods are subjective, costly, time consuming, require sample preparation and may end up in poor grading systems. This calls for the development of a rapid, low-cost, reliable and reproducible analytical method to evaluate coffee quality attributes and eventually chemical compounds of interest (e.g. chlorogenic acid) in coffee beans. The aim of this study was to develop a model able to predict coffee cup quality based on NIR spectra of green coffee beans. NIR spectra of 86 samples of green Arabica beans of varying quality were analysed. Partial least squares (PLS) regression method was used to develop a model correlating spectral data to cupping score data (cup quality). The selected PLS model had a good predictive power for total specialty cup quality and its individual quality attributes (overall cup preference, acidity, body and aftertaste) showing a high correlation coefficient with r-values of 90, 90,78, 72 and 72, respectively, between measured and predicted cupping scores for 20 out of 86 samples. The corresponding root mean square error of prediction (RMSEP) was 1.04, 0.22, 0.27, 0.24 and 0.27 for total specialty cup quality, overall cup preference, acidity, body and aftertaste, respectively. The results obtained suggest that NIR spectra of green coffee beans are a promising tool for fast and accurate prediction of coffee quality and for classifying green coffee beans into different specialty grades. However, the model should be further tested for coffee samples from different regions in Ethiopia and test if one generic or region-specific model should be developed. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Enterovaginal or Vesicovaginal Fistula Control Using a Silicone Cup.

    Science.gov (United States)

    Russell, Katie W; Robinson, Ryan E; Mone, Mary C; Scaife, Courtney L

    2016-12-01

    An enterovaginal or vesicovaginal fistula is a complication resulting in vaginal discharge of succus, urine, or stool that can lead to significant complications. For low-volume fistulae, tampons or pads may be used. With high-volume fistulae, frequent product change can be painful and unpredictable in terms of efficacy. The psychologic distress is profound. Surgery may not be an option, making symptom control the priority. We report the use of a reusable menstrual silicone vaginal cup placed to divert and contain drainage. The menstrual cup provided significant symptom relief. Drainage is immediately diverted from tissue, unlike with tampon or pad use, which involves longer contact periods with caustic fluids. A system was created by adapting the end of the cup by adding silastic tubing and an external leg bag to provide long-term drainage control. Improvement in quality of life is of primary importance when dealing with fistula drainage. This simple and inexpensive device should be considered in those cases in which the drainage can be diverted as a viable option, especially in those who are symptomatic and awaiting surgical repair or in those for whom surgery cannot be performed.

  9. [Biomechanical significance of the acetabular roof and its reaction to mechanical injury].

    Science.gov (United States)

    Domazet, N; Starović, D; Nedeljković, R

    1999-01-01

    The introduction of morphometry into the quantitative analysis of the bone system and functional adaptation of acetabulum to mechanical damages and injuries enabled a relatively simple and acceptable examination of morphological acetabular changes in patients with damaged hip joints. Measurements of the depth and form of acetabulum can be done by radiological methods, computerized tomography and ultrasound (1-9). The aim of the study was to obtain data on the behaviour of acetabular roof, the so-called "eyebrow", by morphometric analyses during different mechanical injuries. Clinical studies of the effect of different loads on acetabular roof were carried out in 741 patients. Radiographic findings of 400 men and 341 women were analysed. The control group was composed of 148 patients with normal hip joints. Average age of the patients was 54.7 years and that of control subjects 52.0 years. Data processing was done for all examined patients. On the basis of our measurements the average size of female "eyebrow" ranged from 24.8 mm to 31.5 mm with standard deviation of 0.93 and in men from 29.4 mm to 40.3 mm with standard deviation of 1.54. The average size in the whole population was 32.1 mm with standard deviation of 15.61. Statistical analyses revealed high correlation coefficients between the age and "eyebrow" size in men (r = 0.124; p 0.05). The examination of the size of collodiaphysial angle and length of "eyebrow" revealed that "eyebrow" length was in inverse proportion to the size of collodiaphysial angle (r = 0.113; p 0.05) and female (r = 0.005; p > 0.05) patients. The "eyebrow" length was proportionally dependent on the size of the shortened extremity in all examined subjects. This dependence was statistically significant both in female (r = 0.208; p < 0.05) and male (r = 0.193; p < 0.05) patients. The study revealed that fossa acetabuli was forward and downward laterally directed. The size, form and cross-section of acetabulum changed during different

  10. Importance of preoperative imaging in acetabular revision surgery - a case report.

    Science.gov (United States)

    Schmitz, Hc; Egidy, Cc; Al-Khateeb, H; Cárdenas, G; Gehrke, T; Kendoff, D

    2012-01-01

    Acetabular defects, particularly as a result of protrusion of acetabular components into the hemipelvis, may cause serious complications during revision procedures as a result of iatrogenic injury to surrounding anatomical structures. In these challenging cases, we advocate the utilisation of preoperative three dimensional imaging. MRI and CT- imaging offer superior understanding of the three-dimensional quality of bony defects and the relationship of implants to important anatomical structures. Appropriate preoperative planning may also prevent major complications during the removal of the pre-existing hardware, prior to re-implantation of implants. Potential complications include injury of nerves, blood vessels and other intrapelvic structures.In our case, a major bony defect of the acetabulum was a result of the protrusion of an implanted reinforcement ring. A preoperative, contrast-enhanced CT scan showed that the urethra was in close proximity to the hook of the reinforcement ring.The preoperative imaging aided in identifying and understanding the potential complications that could occur intraoperatively. Additionally, it delineated the intact anatomic structures prior to surgery, which could have medico-legal implications.The importance of preoperative imaging and the existing literature is discussed within this case description.

  11. An overview of systematic reviews of clinical evidence for cupping therapy

    OpenAIRE

    Huijuan Cao; Mei Han; Xiaoshu Zhu; Jianping Liu

    2015-01-01

    Background: As a traditional treatment method, cupping therapy is widely used in Asian countries. This overview of systematic reviews (SRs) investigated the effectiveness and safety of cupping therapy through an evidence-based approach. Methods: SRs that assessed the effectiveness of cupping therapy for any type of disease were searched through 6 electronic databases. Target diseases, cupping methods, numbers and types of included studies, quality of included trials, main results (includin...

  12. EOS-based cup navigation: Randomised controlled trial in 78 total hip arthroplasties.

    Science.gov (United States)

    Verdier, N; Billaud, A; Masquefa, T; Pallaro, J; Fabre, T; Tournier, C

    2016-06-01

    Minimising the risk of cup implantation outside the safe zone is among the objectives of navigation during total hip arthroplasty (THA). However, given the technical challenges raised by navigation when the patient is lying on the side, many surgeons still use the freehand technique. We conducted a randomised controlled trial to evaluate the new navigation system NAVEOS in the iliac plane, which is easily identified in the lateral decubitus position, with the objective of determining whether NAVEOS navigation decreased the frequency of cup implantation outside the safe zone compared to freehand cup positioning, without increasing the operative time or the frequency of complications. NAVEOS navigation decreases the frequency of cup positioning outside the safe zone compared to freehand positioning. This randomised controlled trial compared cup positioning using NAVEOS navigation versus the freehand technique in patients undergoing primary THA. The safe zone was defined according to Lewinnek as 15±10° of radiological anteversion and 40±10° of radiological inclination. Cup position parameters were measured on computed tomography images obtained 3months after THA. The images were read by two independent observers who were blinded to group assignment. The primary evaluation criterion was cup position within the safe zone. A 1:1 randomisation scheme was used to assign 78 patients (mean age, 68years; age range, 44-91years) to NAVEOS navigation or freehand cup positioning. The two groups were comparable for age, gender distribution, body mass index, and preoperative functional scores. In the NAVEOS group, navigation was discontinued prematurely in 6 patients, because of technical difficulties (n=2) or a marked discrepancy with clinical findings (n=4); however, the intention-to-treat approach was used for the analysis. The proportion of cups in the safe zone was 67% (28/39) in the NAVEOS group and 38% (17/39) in the freehand group (P=0.012). Anteversion was within the

  13. The development and nature of femoral head cam lesions following acetabular fractures.

    Science.gov (United States)

    Berber, Onur; Foote, Julian; Sabharwal, Sanjeeve; Datta, Gorav; Bircher, Martin D

    2014-01-01

    The aim of acetabular fracture fixation is to restore joint congruity with restoration of the articular surface. Poor outcomes are seen where this has not been achieved. Letournel reported a collarette osteophyte seen postoperatively in a proportion of patients, which he suggested was an early precursor to the development of osteoarthritis. This is a retrospective study of patients treated at a tertiary referral unit who developed this lesion. The triangular index was measured in 48 of these patients and then correlated with their clinical findings, Oxford Hip Score and the presence of osteoarthritis. Length of follow-up, fracture classification, and joint congruency were also recorded. Results showed a statistically significant relationship between cam lesion size and the development of osteoarthritis (P = 0.008), cam lesion size and length of follow-up (P = 0.01), and between groin pain and postoperative joint congruency (LR = 0.035). These findings suggest that the appearance of a cam lesion is a poor long-term prognostic marker for the development of osteoarthritis in patients with an acetabular fracture.

  14. Mathematical Analysis of the Effect of Rotor Geometry on Cup Anemometer Response

    Science.gov (United States)

    Sanz-Andrés, Ángel; Sorribes-Palmer, Félix

    2014-01-01

    The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied. The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction. The comparison with the experimental data indicates a nonuniform distribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance. PMID:25110735

  15. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  16. Design and Implementation of a General Decision-Making Model in RoboCup Simulation

    Directory of Open Access Journals (Sweden)

    Changda Wang

    2004-09-01

    Full Text Available The study of the collaboration, coordination and negotiation among different agents in a multi-agent system (MAS has always been the most challenging yet popular in the research of distributed artificial intelligence. In this paper, we will suggest for RoboCup simulation, a typical MAS, a general decision-making model, rather than define a different algorithm for each tactic (e.g. ball handling, pass, shoot and interception, etc. in soccer games as most RoboCup simulation teams did. The general decision-making model is based on two critical factors in soccer games: the vertical distance to the goal line and the visual angle for the goalpost. We have used these two parameters to formalize the defensive and offensive decisions in RoboCup simulation and the results mentioned above had been applied in NOVAURO®, original name is UJDB, a RoboCup simulation team of Jiangsu University, whose decision-making model, compared with that of Tsinghua University, the world champion team in 2001, is a universal model and easier to be implemented.

  17. Elevated lip liner positions improving stability in total hip arthroplasty. An experimental study.

    Directory of Open Access Journals (Sweden)

    Suleman Qurashi

    2018-01-01

    Full Text Available Background: The use of elevated lip polyethylene liners with the acetabular component is relatively common in Total Hip Arthroplasty (THA. Elevated lip liners increase stability of the THA by increasing the jump distance in one direction. However, the elevated lip, conversely, also reduces the primary arc in the opposite direction and leads to early impingement of the neck on the elevated lip, potentially causing instability. The aim of the present study is to determine the total range of motion of the femoral head component within the acetabular component with the elevated lip liner in different orientations within the acetabular cup. Methods: We introduce a novel experimental (ex-vivo framework for studying the effects lip liner orientation on the range of motion of the femoral component. For constant acetabular cup orientation, the elevated lip liner was positioned superiorly and inferiorly. The femoral component range of motion in the coronal, sagittal and axial plane was measured. To avoid any confounding influences of out of plane motion, the femoral component was constrained to move in the tested plane. Results: This experimental set up introduces a rigorous framework in which to test the effects of elevated lip liner orientations on the range of motion of the femoral head component in abduction, adduction, flexion, extension and rotation. The movements of this experimental set-up are directly informative of patient’s maximum potential post-operative range of motion. Initial results show that an inferior placement of the elevated lip increases the effective superior lateral range of motion (abduction for the femoral component, whilst the anatomy of the patient (i.e. their other leg prevents the point of femoral component – acetabular lip impingement being reached (in adduction.

  18. Abordagem cirúrgica inédita para denervação acetabular em cães A new surgical approach to acetabular denervation in dogs

    Directory of Open Access Journals (Sweden)

    Cássio R.A. Ferrigno

    2007-02-01

    Full Text Available Este artigo tem por objetivo demonstrar nova abordagem cirúrgica para denervação seletiva das fibras sensitivas do periósteo acetabular, para tratamento da displasia coxo femoral em cães, conduzidas em 189 articulações. Para tanto, é descrita abordagem da região cranial e dorso-lateral do acetábulo de cães por incisão em forma de meia lua de aproximadamente de três centímetros de extensão, iniciando trocânter maior do fêmur e em direção ao corpo do ílio. Após rebatimento dorsal do músculo glúteo médio, secciona-se parcialmente a inserção do m. glúteo profundo para acesso às regiões citadas. Com auxílio de cureta foi removido, em todos os pacientes, periósteo na margem acetabular cranial e dorso lateral, até a exposição da cortical óssea. Em todos os animais foi possível a abordagem, tanto da face cranial como também acesso para a curetagem da face dorsal do acetábulo, com a técnica descrita, com incisão de pele de aproximadamente 3,2cm. A curetagem da porção cranial do acetábulo foi, em todos os casos realizados, sem visualização do osso, mas de fácil confecção e sem intercorrências de lesão de nervos ou músculos. Em todas as abordagens foi possível visualizar a cápsula articular da articulação coxo femoral, e em nenhum dos animais esta estrutura foi incisada por erro de técnica. Conclui-se que a abordagem cirúrgica descrita no presente trabalho é factível para este tipo de procedimento cirúrgico em cães, promovendo acesso adequado, com mínima invasão e sem complicações de qualquer natureza.The purpose of this study is to demonstrate a new surgical approach for the selective denervation of the sensitive fibers of the acetabular periosteum, for the treatment of hip dysplasia in dogs, conducted in 189 joints.The surgical approach of the cranial and dorso-lateral regions of the acetabular joint in dogs, by moon-shaped incision of approximately 3cm in extension, starting from the

  19. Clinical research evidence of cupping therapy in China: a systematic literature review

    Directory of Open Access Journals (Sweden)

    Wang Qian

    2010-11-01

    Full Text Available Abstract Background Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it. This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. Methods We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. Results 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs, 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. Conclusions According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice.

  20. Clinical research evidence of cupping therapy in China: a systematic literature review.

    Science.gov (United States)

    Cao, Huijuan; Han, Mei; Li, Xun; Dong, Shangjuan; Shang, Yongmei; Wang, Qian; Xu, Shu; Liu, Jianping

    2010-11-16

    Though cupping therapy has been used in China for thousands of years, there has been no systematic summary of clinical research on it.This review is to evaluate the therapeutic effect of cupping therapy using evidence-based approach based on all available clinical studies. We included all clinical studies on cupping therapy for all kinds of diseases. We searched six electronic databases, all searches ended in December 2008. We extracted data on the type of cupping and type of diseases treated. 550 clinical studies were identified published between 1959 and 2008, including 73 randomized controlled trials (RCTs), 22 clinical controlled trials, 373 case series, and 82 case reports. Number of RCTs obviously increased during past decades, but the quality of the RCTs was generally poor according to the risk of bias of the Cochrane standard for important outcome within each trials. The diseases in which cupping was commonly employed included pain conditions, herpes zoster, cough or asthma, etc. Wet cupping was used in majority studies, followed by retained cupping, moving cupping, medicinal cupping, etc. 38 studies used combination of two types of cupping therapies. No serious adverse effects were reported in the studies. According to the above results, quality and quantity of RCTs on cupping therapy appears to be improved during the past 50 years in China, and majority of studies show potential benefit on pain conditions, herpes zoster and other diseases. However, further rigorous designed trials in relevant conditions are warranted to support their use in practice.

  1. [Prophylactic osteotomy of pelvis in dysplastic acetabulum.].

    Science.gov (United States)

    Richtr, M; Sosna, A

    1998-01-01

    Acetabular dysplasia and anatomical changes of pelvis accompanied with gracility of iliac bone pose a problem for a reliable fixation of acetabular component. In extreme cases the bone stock is not sufficient to accommodate the smallest size of the cup. Sometimes even reaming of the bed down to lamina interna is not sufficient for an adequate covering of the implant. Consequently, weakening of the bottom of acetabulum may be not only one of the causes of the failure of the implant but it makes difficult also the following revision surgeries. Therefore in acetabular dysplasia the authors recommend acetabuloplasty of the bottom of acetabulum preserving its original thickness including inner cortex. They recommend to perform osteotomy of the full thickness of the medial wall of acetabulum and move the massive bone graft created in this way farther into pelvis. At the same time they take care to preserve blood supply of the bone graft by retaining corticoperiostal bridge by means of osteoclasia. The suggested procedure allows full coverage of the implant by iliac bone and at the same time preserves a firm support of acetabular fossa. The original thickness of the medial wall of acetabulum is considered by authors as a significant antimigration barrier. In the period 1991 -1994 the authors used this method at Ist Orthopaedic Clinic of 1st Medical Faculty, Charles University in Prague in total in 16 patients. In all of them after 6 months the bone graft was fully absorbed. Remodelling of the bone graft occurred 1 to 2 years after the surgery and after that the thickness of the graft remained the same. Neither any change of the structure nor reduction of the thickness of the graft was found between 3rd and 4th year after the surgery. The nature of trabecular remodelling of the bone graft corresponds to the transfer of forces in loading the graft by acetabular cup. Key words: acetabuloplasty, osteotomy of the medial wall of acetabulum, osteotomy of pelvis, THR, acetabular

  2. A critical comparison of ten disposable cup LCAs

    NARCIS (Netherlands)

    Harst, van der E.J.M.; Potting, J.

    2013-01-01

    Disposable cups can be made from conventional petro-plastics, bioplastics, or paperboard (coated with petro-plastics or bioplastics). This study compared ten life cycle assessment (LCA) studies of disposable cups with the aim to evaluate the robustness of their results. The selected studies have

  3. A level set method for cupping artifact correction in cone-beam CT

    International Nuclear Information System (INIS)

    Xie, Shipeng; Li, Haibo; Ge, Qi; Li, Chunming

    2015-01-01

    Purpose: To reduce cupping artifacts and improve the contrast-to-noise ratio in cone-beam computed tomography (CBCT). Methods: A level set method is proposed to reduce cupping artifacts in the reconstructed image of CBCT. The authors derive a local intensity clustering property of the CBCT image and define a local clustering criterion function of the image intensities in a neighborhood of each point. This criterion function defines an energy in terms of the level set functions, which represent a segmentation result and the cupping artifacts. The cupping artifacts are estimated as a result of minimizing this energy. Results: The cupping artifacts in CBCT are reduced by an average of 90%. The results indicate that the level set-based algorithm is practical and effective for reducing the cupping artifacts and preserving the quality of the reconstructed image. Conclusions: The proposed method focuses on the reconstructed image without requiring any additional physical equipment, is easily implemented, and provides cupping correction through a single-scan acquisition. The experimental results demonstrate that the proposed method successfully reduces the cupping artifacts

  4. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.Y.; Seidman, D.N.

    1977-07-01

    The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA) which serves as the basis of an internal image intensification system (a gain of greater than 10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion cured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30 keV Ar + ion beam is presented as an illustrative example. This Faraday cup was also employed to observe and measure 30 keV Cr + , Mo + or W + and 18 keV Au + ion beams employed for the in-situ irradiation of field-ion microscope specimens

  5. Octopus-like suction cups: from natural to artificial solutions.

    Science.gov (United States)

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  6. Cup detachment during vacuum-assisted vaginal delivery and birth outcome.

    Science.gov (United States)

    Krispin, Eyal; Aviram, Amir; Salman, Lina; Chen, Rony; Wiznitzer, Arnon; Gabbay-Benziv, Rinat

    2017-11-01

    To determine the perinatal outcome associated with cup detachment during vacuum-assisted vaginal delivery (VAVD). A retrospective cohort study of all women attempting VAVD in a tertiary hospital (2012-2014). Singleton-term pregnancies were included. Antepartum fetal death and major fetal structural or chromosomal abnormalities were excluded. Primary outcome was neonatal birth trauma (subgaleal hematoma, subarachnoid hematoma, subdural hematoma, skull fracture, and/or erb's palsy). Secondary outcomes were maternal complications or other neonatal morbidities. Outcomes were compared between women after ≥1 cup detachment (study group) and the rest (control group). Logistic regression analysis was utilized to adjust results to potential confounders. Overall, 1779 women attempted VAVD during study period. Of them, in 146 (8.2%), the cup detached prior to delivery; 130/146 (89%) had a single detachment. After detachment, 4 (2.7%) delivered by cesarean section, 77 (52.7%) delivered after cup reapplication, and 65 (44.6%) delivered spontaneously. Women in the study group were more likely to undergo VAVD due to prolonged second stage, and were characterized by lower rates of metal cup use. Neonates in the detachment group had higher rates of subarachnoid hematoma and composite neonatal birth trauma (2.7 vs. 0.1% and 4.8 vs. 1.8%, respectively, p Cup detachment is associated with a higher rate of adverse neonatal outcome. Cup reapplication should be considered carefully.

  7. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  8. [Development of lipoma following a single cupping massage - a case report].

    Science.gov (United States)

    Schumann, Stefan; Lauche, Romy; Hohmann, Claudia; Zirbes, Thomas; Dobos, Gustav; Saha, Felix Joyonto

    2012-01-01

    The cupping massage is a form of bloodless cupping. This type of cupping is particularly used to treat muscular tension and musculoskeletal pain, such as chronic neck pain; however the data records on mechanisms and potential side effects are not satisfactory. In a study on the effectiveness of cupping massage in patients with chronic neck pain, one patient showed a formation of a lipoma in the cupping area after the first treatment session. Because of the short time interval between therapy and development of the lipoma, a primary cause is not realistic. This adverse event has not been described in the literature before, and the present report describes the case in summary.

  9. Contact of dual mobility implants: effects of cup wear and inclination.

    Science.gov (United States)

    Uddin, M S

    2015-01-01

    Cup wear and inclination on the pelvic bone are significant factors, which change the contact of the articulating surfaces, thus, impacting the long-term performance of hip implants. This paper presents a finite element (FE) analysis of the contact of the dual mobility implants under the influence of cup wear and inclination. A 3D FE model of the implant was developed with the application of equivalent physiological loading and boundary conditions. Effects of cup inclination angle ranging from 45° to 60° and the wear depth ranging from 0 to 2.46 mm equivalent to up to 30 years of the implant's life on the contact pressure and von Mises stress were investigated. Simulation results show that the contact pressure and von Mises stress decrease significantly with a modest wear depth and remains quite in-sensitive to the cup inclination angle and wear depth up to 1.64 mm. With wear depth further up to 2.46 mm, the cup thickness (i.e. cup thinning on worn region) may be more predominant than increasing of contact area between the cup and the head. The wear on the inner surface of the cup is found to rule out the overall contact pressure and stress in the implant. Furthermore, individual and combined effects of both important parameters are analysed and discussed with respect to available clinical/laboratory studies.

  10. Computer-aided designed, three dimensional-printed hemipelvic prosthesis for peri-acetabular malignant bone tumour.

    Science.gov (United States)

    Wang, Baichuan; Hao, Yongqiang; Pu, Feifei; Jiang, Wenbo; Shao, Zengwu

    2018-03-01

    Prosthetic reconstruction may be a promising treatment for peri-acetabular malignant bone tumour; however, it is associated with a high complication rate. Therefore, prosthetic design and approach of prosthetic reconstruction after tumour resection warrant study. We retrospectively analyzed 11 patients with peri-acetabular malignant bone tumours treated by personalized 3D-printed hemipelvic prostheses after en bloc resection between 2015 and 2016. Pre-operative and post-operative pain at rest was assessed according to a 10-cm VAS score. The results of functional improvement were evaluated using the MSTS-93 score at the final follow-up. We also analyzed tumour recurrence, metastases, and complications associated with the reconstruction procedure. All patients were observed for six to 24 months with an average follow-up of 15.5 months. One patient had occasional pain of the involved hip at the final follow-up (VAS, pre vs. post 8 months: 3 vs. 2). The mean MSTS-93 score was 19.2 (range, 13-25). Hip dislocation was detected in two patients, while delayed wound healing occurred in one patient. One patient with mesenchymal chondrosarcoma had a left iliac bone metastasis. Local tumour recurrence was not observed. Reconstruction of bony defect after tumour resection using personalized 3D-printed hemipelvic prostheses can obtain acceptable functional results without severe complications. Based on previous reports and our results, we believe that reconstruction arthroplasty using 3D-printed hemipelvic prostheses will provide a promising alternative for those patients with peri-acetabular malignant bone tumours. Level IV, therapeutic study.

  11. A Facile Approach to Evaluate Thermal Insulation Performance of Paper Cups

    Directory of Open Access Journals (Sweden)

    Yudi Kuang

    2015-01-01

    Full Text Available Paper cups are ubiquitous in daily life for serving water, soup, coffee, tea, and milk due to their convenience, biodegradability, recyclability, and sustainability. The thermal insulation performance of paper cups is of significance because they are used to supply hot food or drinks. Using an effective thermal conductivity to accurately evaluate the thermal insulation performance of paper cups is complex due to the inclusion of complicated components and a multilayer structure. Moreover, an effective thermal conductivity is unsuitable for evaluating thermal insulation performance of paper cups in the case of fluctuating temperature. In this work, we propose a facile approach to precisely analyze the thermal insulation performance of paper cups in a particular range of temperature by using an evaluation model based on the MISO (Multiple-Input Single-Output technical theory, which includes a characterization parameter (temperature factor and a measurement apparatus. A series of experiments was conducted according to this evaluation model, and the results show that this evaluation model enables accurate characterization of the thermal insulation performance of paper cups and provides an efficient theoretical basis for selecting paper materials for paper cups.

  12. Why it is harder to run RoboCup in South Africa

    Directory of Open Access Journals (Sweden)

    Alexander Ferrein

    2016-10-01

    Full Text Available Robots are widely used as a vehicle to spark interest in science and technology in learners. A number of initiatives focus on this issue, for instance, the Roberta Initiative, the FIRST Lego League, the World Robot Olympiad and RoboCup Junior. Robotic competitions are valuable not only for school learners but also for university students, as the RoboCup initiative shows. Besides technical skills, the students get some project exposure and experience what it means to finish their tasks on time. But qualifying students for future high-tech areas should not only be for students from developed countries. In this article, we present our experiences with research and education in robotics within the RoboCup initiative, in Germany and South Africa; we report on our experiences with trying to get the RoboCup initiative in South Africa going. RoboCup has a huge support base of academic institutions in Germany; this is not the case in South Africa. We present our ‘north–south’ collaboration initiatives in RoboCup between Germany and South Africa and discuss some of the reasons why we think it is harder to run RoboCup in South Africa.

  13. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  14. Development of an external Faraday cup for beam current measurements

    International Nuclear Information System (INIS)

    Kim, Kye-Ryung; Jung, Myung-Hwan; Ra, Se-Jin; Lee, Seok-Ki

    2010-01-01

    In general, beam current measurements are very important for many kinds of experiments using highly energetic particle beams at accelerators, such as cyclotrons, linacs, etc. The Faraday cup is known to be one of the most popular beam current measurement tools. We developed an external Faraday cup to measure the beam current at a dedicated beam line for low-flux experiments installed at the MC-50 cyclotron of Korea Institute of Radiological and Medical Sciences (KIRAMS). It was designed for external beam current measurements and is composed of a vacuum chamber, an entrance window, a collimator, a electrostatic suppressor ring, and a cup. The window is made of 75-um-thick Kapton film, and the diameter of the collimator is 10 mm or 20 mm. The ring and the cup has 5-cm inner diameters, and the thickness of the bottom of the cup is 2 cm, which is enough to absorb the total proton energy up to 45 MeV. Using this external Faraday cup, we measured the beam current from the cyclotron, and we compared measured flux to the results from film dosimetry using GAF films.

  15. Sound of a cup with and without instant coffee

    Science.gov (United States)

    Morrison, Andrew; Rossing, Thomas D.

    2002-05-01

    An empty coffee cup, like an ancient Chinese two-tone bell, emits two distinctly different tones, depending upon where it is tapped. When it is filled with hot water, and some instant coffee is added, however, a whole new set of sounds is heard when the cup is tapped. The pitch rises an octave or more as the foam clears due to the dramatic change in the speed of sound in the bubble-filled liquid. A similar, but smaller, effect was noted in beer by Bragg [The World of Sound (1968)] and in hot chocolate by Crawford [Am. J. Phys. (1982)]. We describe the modes of vibration in a coffee cup and the sound emitted by a coffee cup as filled with instant coffee as the bubble density changes.

  16. Recording injuries among World Cup skiers and snowboarders: a methodological study.

    Science.gov (United States)

    Flørenes, T W; Nordsletten, L; Heir, S; Bahr, R

    2011-04-01

    No long-term injury surveillance programs exist for competitive skiing or snowboarding. The objective of this study was, therefore, to compare different methods to record injuries among World Cup athletes in alpine, freestyle, and cross-country skiing, snowboarding, ski jumping and Nordic combined. Information regarding injuries sustained during the 2006-2007 winter season was recorded through three separate and independent systems: prospective injury reports by technical delegates (TD) from the International Ski Federation, prospective medical team registration by selected teams, and retrospective athlete interviews at the end of the season. A total of 100 unique injuries to 602 World Cup athletes were identified from any of the three recording methods. Of these, 91% were registered through the athlete interviews, 47% by the medical team registration and 27% by the TD reports. Only 20 injuries (20%) were captured by all three methods. A total of 64 time-loss injuries were registered. The interviews captured 60 (94%), the medical team registration 39 (61%), and the TD reports 23 (36%) time-loss injuries, while 18 (28%) were registered by all three systems. Retrospective interviews with athletes/coaches regarding injuries during the last 6 months gave the most complete picture of injuries to World Cup skiers and snowboarders. © 2009 John Wiley & Sons A/S.

  17. Brazil World Cup Challenges

    Directory of Open Access Journals (Sweden)

    MANSUR, R.

    2012-12-01

    Full Text Available Overcoming the productivity challenge is the main benefit of the 2014 World Cup for Brazilian people. The sustainable development of our cultural tourism industry will catapult the new middle class growing up rate.

  18. A low-mass faraday cup experiment for the solar wind

    Science.gov (United States)

    Lazarus, A. J.; Steinberg, J. T.; Mcnutt, R. L., Jr.

    1993-01-01

    Faraday cups have proven to be very reliable and accurate instruments capable of making 3-D velocity distribution measurements on spinning or 3-axis stabilized spacecraft. Faraday cup instrumentation continues to be appropriate for heliospheric missions. As an example, the reductions in mass possible relative to the solar wind detection system about to be flown on the WIND spacecraft were estimated. Through the use of technology developed or used at the MIT Center for Space Research but were not able to utilize for WIND: surface-mount packaging, field-programmable gate arrays, an optically-switched high voltage supply, and an integrated-circuit power converter, it was estimated that the mass of the Faraday Cup system could be reduced from 5 kg to 1.8 kg. Further redesign of the electronics incorporating hybrid integrated circuits as well as a decrease in the sensor size, with a corresponding increase in measurement cycle time, could lead to a significantly lower mass for other mission applications. Reduction in mass of the entire spacecraft-experiment system is critically dependent on early and continual collaborative efforts between the spacecraft engineers and the experimenters. Those efforts concern a range of issues from spacecraft structure to data systems to the spacecraft power voltage levels. Requirements for flight qualification affect use of newer, lighter electronics packaging and its implementation; the issue of quality assurance needs to be specifically addressed. Lower cost and reduced mass can best be achieved through the efforts of a relatively small group dedicated to the success of the mission. Such a group needs a fixed budget and greater control over quality assurance requirements, together with a reasonable oversight mechanism.

  19. Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis.

    Science.gov (United States)

    Wang, Xuyi; Peng, Jianping; Li, De; Zhang, Linlin; Wang, Hui; Jiang, Leisheng; Chen, Xiaodong

    2016-10-04

    The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from the biomechanical view? If not, is there any correlation between the biomechanically optimal position of the acetabular fragment and the severity of dysplasia? Four finite element models with different severities of dysplasia were developed. The virtual periacetabular osteotomy was performed with the acetabular fragment rotated anterolaterally to incremental center-edge angles; then, the contact area and pressure and von Mises stress in the cartilage were calculated at different correction angles. The optimal position of the acetabular fragment for patients 1, 2, and 3 was when the acetabular fragment rotated 17° laterally (with the lateral center-edge angle of 36° and anterior center-edge angle of 58°; both were slightly larger than the "normal" range), 25° laterally following further 5° anterior rotation (with the lateral center-edge angle of 31° and anterior center-edge angle of 51°; both were within the "normal" range), and 30° laterally following further 10° anterior rotation (with the lateral center-edge angle of 25° and anterior center-edge angle of 40°; both were less than the "normal" range), respectively. The optimal corrective position of the acetabular fragment is severity dependent rather than within the radiological "normal" range for developmental dysplasia of the hip. We prudently proposed that the optimal correction center-edge angle of mild, moderate, and severe developmental dysplasia of the hip is slightly larger than the "normal" range, within the "normal" range, and less than the lower limit of the "normal" range, respectively.

  20. Wear numbers for ball cup and journal bearings

    NARCIS (Netherlands)

    Ligterink, D.J.; Moes, H.

    1980-01-01

    A wear number is defined for ball cup bearings and for journal bearings where the cup and the cylindrical bearing are made of soft material. This dimensionless wear number provides a relation between the following five quantities: the radius of the ball or the length of the journal bearing in

  1. Optimized Extraction of H– by Three-Electrode Faraday Cup System in Magnetized Sheet Plasma Ion Source

    Directory of Open Access Journals (Sweden)

    M. S. Fernandez

    2003-06-01

    Full Text Available A locally designed rectangular parallelepiped, three-electrode Faraday cup system has been developed.Its design incorporates the capability of simultaneous extraction and deposition of the H– ions on substrates.The device functions to attain prescribed selectivity conditions of extracted ions, with controlled energies,for deposition or adsorption. It has been proven to detect the ions at filter bias voltage of 13.61 V with acurrent density of 5.3 A/m2 that is relatively higher than reported (Abate & Ramos, 2000.

  2. CUP promotes deadenylation and inhibits decapping of mRNA targets

    Science.gov (United States)

    Igreja, Catia; Izaurralde, Elisa

    2011-01-01

    CUP is an eIF4E-binding protein (4E-BP) that represses the expression of specific maternal mRNAs prior to their posterior localization. Here, we show that CUP employs multiple mechanisms to repress the expression of target mRNAs. In addition to inducing translational repression, CUP maintains mRNA targets in a repressed state by promoting their deadenylation and protects deadenylated mRNAs from further degradation. Translational repression and deadenylation are independent of eIF4E binding and require both the middle and C-terminal regions of CUP, which collectively we termed the effector domain. This domain associates with the deadenylase complex CAF1–CCR4–NOT and decapping activators. Accordingly, in isolation, the effector domain is a potent trigger of mRNA degradation and promotes deadenylation, decapping and decay. However, in the context of the full-length CUP protein, the decapping and decay mediated by the effector domain are inhibited, and target mRNAs are maintained in a deadenylated, repressed form. Remarkably, an N-terminal regulatory domain containing a noncanonical eIF4E-binding motif is required to protect CUP-associated mRNAs from decapping and further degradation, suggesting that this domain counteracts the activity of the effector domain. Our findings indicate that the mode of action of CUP is more complex than previously thought and provide mechanistic insight into the regulation of mRNA expression by 4E-BPs. PMID:21937713

  3. Development of integrated damage detection system for international America's Cup class yacht structures using a fiber optic distributed sensor

    Science.gov (United States)

    Akiyoshi, Shimada; Naruse, Hiroshi; Uzawa, Kyoshi; Murayama, Hideaki; Kageyama, Kazuro

    2000-06-01

    We constructed a new health monitoring system to detect damage using a fiber optic distributed sensor, namely a Brillouin optical time domain reflectometer (BOTDR), and installed it in International America's Cup Class (IACC) yachts, the Japanese entry in America's Cup 2000. IACC yachts are designed to be as fast as possible, so it is essential that they are lightweight and encounter minimum water resistance. Advanced composite sandwich structures, made with carbon fiber reinforced plastic (CFRP) skins and a honeycomb core, are used to achieve the lightweight structure. Yacht structure designs push the strength of the materials to their limit and so it is important to detect highly stressed or damaged regions that might cause a catastrophic fracture. The BOTDR measures changes in the Brillouin frequency shift caused by distributed strain along one optical fiber. We undertook two experiments: a pulling test and a four point bending test on a composite beam. The former showed that no slippage occurred between the optical fiber glass and its coating. The latter confirmed that a debonding between the skin and the core of 300 mm length could be found with the BOTDR. Next we examined the effectiveness with which this system can assess the structural integrity of IACC yachts. The results show that our system has the potential for use as a damage detection system for smart structures.

  4. Inguinal Abnormalities in Male Patients with Acetabular Fractures Treated Using an Ilioinguinal Exposure

    Directory of Open Access Journals (Sweden)

    Reza Firoozabadi

    2015-09-01

    Full Text Available Purpose: Surgeons performing an ilioinguinal exposure for acetabular fracture surgery need to be aware of aberrant findings such as inguinal hernias and spermatic cord lesions. The purpose of this study is to report these occurrences in a clinical series of adult males undergoing acetabular fracture fixation and a series of adult male cadavers. The secondary aim is to characterize these abnormalities to aid surgeons in detecting these abnormalities preoperatively and coordinating a surgical plan with a general surgeon.Methods: Clinical study- Retrospective review of treated acetabular fractures through an ilioinguinal approach. Incidence of inguinal canal and spermatic cord abnormalities requiring general surgery consultation were identified. Corresponding CT scans were reviewed and radiographic characteristics of the spermatic cord abnormalities and/or hernias were noted.Cadaveric study- 18 male cadavers dissected bilaterally using an ilioinguinal exposure. The inguinal canal and the contents of the spermatic cord were identified and characterized.Results: Clinical Study- 5.7% (5/87 of patients had spermatic cord lesion and/or inguinal hernia requiring general surgical intervention. Preoperative pelvic CT scan review identified abnormalities noted intraoperatively in four of the five patients. Cord lipomas visualized as enlargements of the spermatic cord with homogeneous density. Hernias visualized as enlarged spermatic cords with heterogeneous density. Cadaver Study- 31% (11/36 of cadavers studied had spermatic cord and/or inguinal canal abnormalities. Average cord diameter in those with abnormalities was 24.9 mm (15-28 compared to 16 mm (11-22 in normal cords, which was statistically significant.Conclusion: The clinical and cadaveric findings emphasize the importance of understanding inguinal abnormalities and the value of detecting them preoperatively. The preoperative pelvic CT scans were highly sensitive in detecting inguinal abnormalities.

  5. [Stress analysis on the acetabular side of bipolar hemiarthroplasty by the two-dimensional finite element method incorporating the boundary friction layer].

    Science.gov (United States)

    Ichihashi, K; Imura, S; Oomori, H; Gesso, H

    1994-11-01

    We compared the biomechanical characteristics of bipolar and unipolar hemiarthroplasty on the proximal migration of the outer head by determining the von Mises stress distribution and acetabular (outer head) displacement with clinical assessment of hemiarthroplasty in 75 patients. This analysis used the two-dimensional finite element method, which incorporated boundary friction layers on both the inner and outer bearings of the prosthesis. Acetabular reaming increased stress within the pelvic bone and migration of the outer head. A combination of the acetabular reaming and bone transplantation increased the stress within the pelvic bone and grafted bone, and caused outer head migration. These findings were supported by clinical results. Although the bipolar endoprosthesis was biomechanically superior to the unipolar endoprosthesis, migration of the outer head still occurred. The bipolar endoprosthesis appeared to be indicated in cases of a femoral neck fracture or of avascular necrosis in the femoral head, but its use in cases of osteoarthritis in the hip required caution.

  6. USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

  7. Effect of dispersed phase particle size on microstructure of cup fracture

    International Nuclear Information System (INIS)

    Goritskij, V.M.; Guseva, I.A.

    1978-01-01

    A correlation-regressive analysis has been carried out to reveal the influence of the size and the mean distance between the disperse particles of deposits V(C,N) on the microstructure (size of micropores and cups, density of the cups) of a viscous cup-like fracture of specimens made of 30Kh2NMFA grade steel that has been hardened and annealed. It is shown that micropores develop at relatively large particles of deposits V(C,N) (>=0.04/m). A strong correlation linear connection exists between the size of a disperse particle of deposits V(C,N), the size of micropore and cup. This connection is attributable to the close, pairwise correlative connection between the size of the particle and the micropore, the micropore and the cup

  8. Agro-ecological potential of the cup plant (Silphium perfoliatum L.) from a biodiversity perspective

    Science.gov (United States)

    Schrader, Stefan; Schorpp, Quentin; Lena Müller, Anna; Dauber, Jens

    2017-04-01

    The cup plant (Silphium perfoliatum L.) is an alternative bioenergy crop that may contribute to a more environmentally friendly production of renewable resources. The potential benefits of the cup plant are the perennial cultivation without tillage and its flowering-characteristics. Hence it can be hypothesized that beneficial organisms are promoted which in turn improves the provision of ecosystem services like soil fertility and pollination. To date biomass production in Germany is based mainly on cropping systems like intensive maize cultivation that bear a risk for biodiversity and ecosystem services. The importance to counteract this development increases considering the large land requirements for significant generation of energy from biomass. To what extent cropping of the cup plant meets the expectations of a sustainable biomass production was investigated within a comprehensive assessment of soil fauna communities (earthworms, collembolans, nematodes) including their functional groups as well as pollinating insects (bees and hoverflies) including the quantification of pollen and nectar in cup-plant cultivation systems with a crop management close to agricultural practice. From the results it became obvious that the cup plant as a bioenergy crop has got the necessary potential to mitigate the negative development of biodiversity and ecosystem services, especially in regions with a large share of maize monocultures. This agro-ecological potential can only be reached if certain agronomic requirements are met, i.e. a late harvest and cultivation periods of at least five years. Under these conditions the landscape context has to be considered. Semi-natural habitats in the surrounding landscape are required for nesting and larval development of wild pollinator groups. The development of biological functions in soil is tied to the land use history i.e. previous land use: Positive developments are expected for conversion of intensively managed crop fields to the

  9. Cupping for chronic nonspecific neck pain: a 2-year follow-up.

    Science.gov (United States)

    Lauche, Romy; Cramer, Holger; Langhorst, Jost; Dobos, Gustav

    2013-01-01

    Several trials have shown that cupping might be an effective treatment for chronic nonspecific neck pain, but little is known about the long-term effectiveness. This study aimed to investigate long-term effects of a short series of cupping; therefore additional follow-up measurements were conducted 2 years after completion of 3 studies. Participants from 3 randomized waitlist controlled trials on cupping for chronic nonspecific neck pain were followed 2 years after treatment. Outcome measures included neck pain intensity (100 mm Visual Analog Scale; VAS), functional disability (Neck Disability Index, NDI), and health-related quality of life (Short Form 36 Health Survey Questionnaire; SF-36). 133 of 150 patients had received cupping treatment and were contacted; 82 of them (61.7%) returned the follow-up questionnaires. No effect was found for neck pain intensity, but for physical function (∆ NDI: -3.15; 95% CI: -5.89; -0.41; p = 0.025) and quality of life (∆ physical component summary: 2.97; 95% CI: 0.97; 4.97; p = 0.004; ∆ bodily pain: 14.53; 95 % CI: 9.67; 19.39; p cupping effect was 8.9 ± 8.7 months with 16 patients reporting that neck pain had not yet reached the level before cupping. The majority of the patients did not continue cupping therapy, mostly due to lack of providers, costs or loss of interest. A series of cupping treatments did not influence neck pain intensity on the longer term, however significant increases were found for physical function and quality of life in patients with chronic nonspecific neck pain. Due to the considerable drop-out rate conclusions are limited. There is evidence suggesting that cupping treatment might have sustainable effects in some patients. Further randomized controlled trials with long-term follow-up are urgently needed for conclusive judgment of long-term effectiveness. © 2013 S. Karger GmbH, Freiburg.

  10. Urine cup for collection of urine from cows.

    Science.gov (United States)

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  11. Faraday cup for analyzing multi-ion plasma

    International Nuclear Information System (INIS)

    Fujita, Takao

    1987-01-01

    A compact and convenient ion analyzer (a kind of a Faraday cup) is developed in order to analyze weakly ionized multi-ion plasmas. This Faraday cup consists of three mesh electrodes and a movable ion collector. With a negative gate pulse superimposed on the ion retarding bias, ions are analyzed by means of time-of-flight. The identification of ion species and measurements of ion density and ion temperature are studied. (author)

  12. Complementary Coffee Cups

    Science.gov (United States)

    Banchoff, Thomas

    2006-01-01

    What may have been the birth of a new calculus problem took place when the author noticed that two coffee cups, one convex and one concave, fit nicely together, and he wondered which held more coffee. The fact that their volumes were about equal led to the topic of this article: complementary surfaces of revolution with equal volumes.

  13. Cup Anemometer Overspeeding

    DEFF Research Database (Denmark)

    Busch, N. E.; Kristensen, Leif

    1976-01-01

    Statistical considerations are applied to a general equation of motion for cup anemometers in a turbulent wind. It is shown that the relative overspeeding ΔS/S can be expressed as ΔS/S = Ih2 · Js(l0/Λs) + cIw2, where Is and Iw are the horizontal and the vertical turbulence intensifies, respectively...

  14. Surgical treatment of acetabular fractures: clinical and radiological results and its complications

    International Nuclear Information System (INIS)

    Martinez, C; Rey, R.

    2011-01-01

    The objective of this work is to analyse a serie of consecutive cases of surigically treated acetabular fractures, evaluating middle-term clinical and radiological results. A retrospective analysis of clinical histories, surgical forms and X-rays was performed for 42 patients who underwent surgery in two centers (Instituto Nacional de Ortopedia y Traumatologia [INOT] and Banco de Protesis), from July 2001 through August 2007

  15. Is radiation superior to indomethacin to prevent heterotopic ossification in acetabular fractures?: a systematic review.

    NARCIS (Netherlands)

    Blokhuis, T.J.; Frolke, J.P.M.

    2009-01-01

    Heterotopic ossification is a well-known complication after fixation of an acetabular fracture. Indomethacin and radiation therapy are used as prophylaxis to prevent heterotopic ossification. It is unclear, however, whether either is superior, although this may relate to lack of power in individual

  16. Cup regulates oskar mRNA stability during oogenesis.

    Science.gov (United States)

    Broyer, Risa M; Monfort, Elena; Wilhelm, James E

    2017-01-01

    The proper regulation of the localization, translation, and stability of maternally deposited transcripts is essential for embryonic development in many organisms. These different forms of regulation are mediated by the various protein subunits of the ribonucleoprotein (RNP) complexes that assemble on maternal mRNAs. However, while many of the subunits that regulate the localization and translation of maternal transcripts have been identified, relatively little is known about how maternal mRNAs are stockpiled and stored in a stable form to support early development. One of the best characterized regulators of maternal transcripts is Cup - a broadly conserved component of the maternal RNP complex that in Drosophila acts as a translational repressor of the localized message oskar. In this study, we have found that loss of cup disrupts the localization of both the oskar mRNA and its associated proteins to the posterior pole of the developing oocyte. This defect is not due to a failure to specify the oocyte or to disruption of RNP transport. Rather, the localization defects are due to a drop in oskar mRNA levels in cup mutant egg chambers. Thus, in addition to its role in regulating oskar mRNA translation, Cup also plays a critical role in controlling the stability of the oskar transcript. This suggests that Cup is ideally positioned to coordinate the translational control function of the maternal RNP complex with its role in storing maternal transcripts in a stable form. Published by Elsevier Inc.

  17. Cupping therapy: An analysis of the effects of suction on skin and the possible influence on human health.

    Science.gov (United States)

    Lowe, Duane T

    2017-11-01

    Cupping therapy is a traditional therapy that has been employed worldwide for thousands of years. Despite a lack of quality clinical studies evaluating the efficacy of cupping therapy, its long history and widespread use throughout the world suggests the commonly claimed health benefits should not be completely discounted as without merit. The goal of this paper is to present the research detailing what is known concerning the effects of suction on skin and underlying tissue, and the reaction of the body to that stimulus. Understanding the literature on the physiological effects of this mechanical force may help elaborate an explanation for the advertised local and systemic effects of cupping therapy. Negative pressure causes stretching of the skin and underlying tissue and dilation of the capillaries. This stimulates an increase in tissue blood flow, eventually leading to capillary rupture and ecchymosis. Macrophages phagocytize the erythrocytes in the extravascular space which stimulates the production of Heme Oxygenase-1 (HO-1) to metabolize the heme. Heme catalysis results in the production of carbon monoxide (CO), biliverdin(BV)/bilirubin(BR) and iron. HO-1, BV, BR, and CO has been shown to have antioxidant, anti-inflammatory, antiproliferative, and neuromodulatory effects in animal and human systems. These substances also stimulate a shift of macrophages to the anti-inflammatory M2 phenotype. There is evidence that the effects are both local and systemic. Besides the mechanical effect of cupping increasing the local blood flow and stretching underlying tissue, activation of the HO-1 system could account for many of cupping therapy's claimed local and systemic health benefits. Published by Elsevier Ltd.

  18. Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.

    Science.gov (United States)

    Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho

    2017-12-01

    To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all Pcup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; Pcup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; Pcup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.

  19. 'Our struggles are bigger than the World Cup': civic activism, state-society relations and the socio-political legacies of the 2010 FIFA World Cup.

    Science.gov (United States)

    Cornelissen, Scarlett

    2012-06-01

    South Africa's hosting of the 2010 FIFA World Cup saw a large number of public demonstrations, strikes and other forms of civic campaigning. World Cup activism was both preceded and followed by extensive and intensifying public unrest and industrial action that in the period before the tournament, threatened to derail the event. This paper assesses the motivations, forms and implications of the activism during South Africa's staging of the FIFA finals and interprets them against the larger context of shifting state-society relations in the country. There are two purposes to the analysis. First, to explore the underlying internal social forces that gave shape to the protests at the time, and the possible influence of the exogenous politics of mega-event social mobilization. Second, the implications and outcomes of these dynamics for longer term socio-political processes in the country are considered. The activism displayed many of the features of the politics of contestation of sport mega-events today. Importantly, however, the activism stemmed from a particular systemic dynamic and reflected changing relations in the post-apartheid political community. Therefore, while the World Cup was used as a strategic opportunity by many advocacy groups, it was one that rather fleetingly and ambivalently presented an additional platform to such groups in an otherwise on-going set of political battles. Rather than a strong case study of sport's transformative capacity, the civic campaigning during South Africa's World Cup demonstrates the way a sport mega-event can be used as a strategic entry point by civil society groups in their engagement with the state, although this can occur with greater or lesser success. © London School of Economics and Political Science 2012.

  20. Dry cupping for plantar fasciitis: a randomized controlled trial.

    Science.gov (United States)

    Ge, Weiqing; Leson, Chelsea; Vukovic, Corey

    2017-05-01

    [Purpose] The purpose of this study was to determine the effects of dry cupping on pain and function of patients with plantar fasciitis. [Subjects and Methods] Twenty-nine subjects (age 15 to 59 years old, 20 females and 9 males), randomly assigned into the two groups (dry cupping therapy and electrical stimulation therapy groups), participated in this study. The research design was a randomized controlled trial (RCT). Treatments were provided to the subjects twice a week for 4 weeks. Outcome measurements included the Visual Analogue Pain Scale (VAS) (at rest, first in the morning, and with activities), the Foot and Ankle Ability Measure (FAAM), the Lower Extremity Functional Scale (LEFS), as well as the pressure pain threshold. [Results]The data indicated that both dry cupping therapy and electrical stimulation therapy could reduce pain and increase function significantly in the population tested, as all the 95% Confidence Intervals (CIs) did not include 0 except for the pressure pain threshold. There was no significant difference between the dry cupping therapy and electrical stimulation groups in all the outcome measurements. [Conclusion] These results support that both dry cupping therapy and electrical stimulation therapy could reduce pain and increase function in the population tested.

  1. [Acetabular anteversion angle of the hip in the Mexican adult population measured with computed tomography].

    Science.gov (United States)

    Rubalcava, J; Gómez-García, F; Ríos-Reina, J L

    2012-01-01

    Knowledge of the radiogrametric characteristics of a specific skeletal segment in a healthy population is of the utmost clinical importance. The main justification for this study is that there is no published description of the radiogrametric parameter of acetabular anteversion in a healthy Mexican adult population. A prospective, descriptive and cross-sectional study was conducted. Individuals of both genders older than 18 years and orthopedically healthy were included. They underwent a two-dimensional axial tomographic study of both hips to measure the acetabular anteversion angles. The statistical analysis consisted of obtaining central trend and scatter measurements. A multivariate analysis of variance (ANOVA) and statistical significance were performed. 118 individuals were studied, 60 males and 58 females, with a mean age of 47.7 +/- 16.7, and a range of 18-85 years. The anteversion of the entire group was 18.6 degrees + 4.1 degrees. Anteversion in males was 17.3 degrees +/- 3.5 degrees (10 degrees - 25 degrees) and in females 19.8 degrees +/- 4.7 degrees (10 degrees - 31 degrees). There were no statistically significant differences (p right and left anteversion in the entire group. However, there were statistically significant differences (p > or = 0.005) both in the right and left sides when males and females were compared. Our study showed that there are great variations in the anteversion ranges of a healthy population. When our results are compared with those published by other authors the mean of most measurements exceeds 15 degrees. This should be useful to make therapeutic decisions that involve acetabular anteversion.

  2. Development and calibration of a self-recording cup anemometer for ...

    African Journals Online (AJOL)

    UFUOMA

    The instrument design consists of six electronics block stages: Power stage which supplies ... Key words: Wind speed, cup anemometer, sensor, decoder, spindle. INTRODUCTION ... and develop a low cost digital cup anemometer, which is.

  3. Acetabular Reconstruction with the Burch-Schneider Antiprotrusio Cage and Bulk Allografts: Minimum 10-Year Follow-Up Results

    Directory of Open Access Journals (Sweden)

    Dario Regis

    2014-01-01

    Full Text Available Reconstruction of severe pelvic bone loss is a challenging problem in hip revision surgery. Between January 1992 and December 2000, 97 hips with periprosthetic osteolysis underwent acetabular revision using bulk allografts and the Burch-Schneider antiprotrusio cage (APC. Twenty-nine patients (32 implants died for unrelated causes without additional surgery. Sixty-five hips were available for clinical and radiographic assessment at an average follow-up of 14.6 years (range, 10.0 to 18.9 years. There were 16 male and 49 female patients, aged from 29 to 83 (median, 60 years, with Paprosky IIIA (27 cases and IIIB (38 cases acetabular bone defects. Nine cages required rerevision because of infection (3, aseptic loosening (5, and flange breakage (1. The average Harris hip score improved from 33.1 points preoperatively to 75.6 points at follow-up (P<0.001. Radiographically, graft incorporation and cage stability were detected in 48 and 52 hips, respectively. The cumulative survival rates at 18.9 years with removal for any reason or X-ray migration of the cage and aseptic or radiographic loosening as the end points were 80.0% and 84.6%, respectively. The use of the Burch-Schneider APC and massive allografts is an effective technique for the reconstructive treatment of extensive acetabular bone loss with long-lasting survival.

  4. Clad vent set cup open end (closure weld zone) wall-thickness study

    Energy Technology Data Exchange (ETDEWEB)

    Ulrich, G.B.; Sherrill, M.W.

    1994-09-01

    The wall thickness at the open end of Clad Vent Set (CVS) cups is a very important parameter for maintaining control of the fueled CVS closure weld process. Ideally, the wall thickness in the closure weld zone should be constant. The DOP-26 iridium alloy is very difficult to machine; therefore, key dimensional features are established during the two-draw warm-forming operation. Unfortunately, anisotropy in the forming blanks produces four ears at the open end of each cup. Formation of these ears produces axial and circumferential variations in wall thickness. The cup certification requirement is that the wall thickness in the closure weld zone, defined as the 2.5-mm band at the open end of a cup, measure from 0.63 to 0.73 mm. The wall thickness certification data for the open end of the CVS cups have been statistically evaluated. These data show that the cups recently produced for the Cassini mission have well-controlled open-end wall thicknesses.

  5. Up for the Cup.

    Science.gov (United States)

    Lawson, Duncan A.

    1996-01-01

    Presents an activity related to probability in order to answer a question based on the English football league. The question is "What is the probability that the FA Cup Final will be between the same two teams that played in the previous tournament?". (ASK)

  6. Preclinical, clinical, and over-the-counter postmarketing experience with a new vaginal cup: menstrual collection.

    Science.gov (United States)

    North, Barbara B; Oldham, Michael J

    2011-02-01

    Menstrual cups have been available for decades, but their use is limited by bulky design and the need for multiple sizes. The Softcup® (Instead, Inc., San Diego, CA) is a simple single-size disposable over-the-counter (OTC) menstrual cup that compresses to tampon shape to facilitate insertion and can be worn during coitus. This report describes preclinical evaluation, clinical testing, and postmarketing monitoring of the Softcup. Preclinical testing complied with U.S. Food and Drug Administration (FDA) guidelines and used standard United States Pharmacopoeia methodologies for assessment of potential toxicity. Clinical testing enrolled 406 women in seven U.S. centers. A detailed written questionnaire assessed safety, acceptability, and effectiveness for menstrual collection. Study safety parameters included pelvic examinations, Pap smears, colposcopy, urinalysis, vaginal pH, wet mounts, gram stain, and vaginal microflora cultures. Postmarketing surveillance of over 100 million Softcups has been conducted by the manufacturer and by the FDA Medwatch system. No toxicity or mutagenicity was observed in preclinical evaluations. In clinical testing, after three cycles of cup use, 37% of subjects rated the cup as better than, 29% as worse than, and 34% as equal to pads or tampons. The cup was preferred for comfort, dryness, and less odor. Cups received lower ratings for disposal and convenience. Eighty-one percent of enrolled women were able to insert and remove their first cup using only written instructions. Use difficulties resulting in study discontinuations included cramping (1%), leakage (1%), and improper fit (3%). No safety parameters were adversely affected. No significant health risks were reported during postmarketing surveillance. These results demonstrate that a single-size vaginal device has no significant health risks and is acceptable to many women without the need for fitting or other medical services.

  7. Köebner phenomenon induced by cupping therapy in a psoriasis patient.

    Science.gov (United States)

    Yu, Rui-Xing; Hui, Yun; Li, Cheng-Rang

    2013-06-15

    Psoriasis is a chronic, immune-mediated inflammatory and refractory disease. The koebner phenomenon, which can be induced by trauma, is common in psoriasis patients. Herein, we report a patient with psoriasis who was treated by cupping therapy and subsequently developed the koebner phenomenon (KP) at the cupped sites. To our knowledge, it is the first report about cupping therapy leading to KP in a psoriasis patient.

  8. Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction-First Clinical Results.

    Science.gov (United States)

    Schumann, Steffen; Sato, Yoshinobu; Nakanishi, Yuki; Yokota, Futoshi; Takao, Masaki; Sugano, Nobuhiko; Zheng, Guoyan

    2015-11-01

    In the following, we will present a newly developed X-ray calibration phantom and its integration for 2-D/3-D pelvis reconstruction and subsequent automatic cup planning. Two different planning strategies were applied and evaluated with clinical data. Two different cup planning methods were investigated: The first planning strategy is based on a combined pelvis and cup statistical atlas. Thereby, the pelvis part of the combined atlas is matched to the reconstructed pelvis model, resulting in an optimized cup planning. The second planning strategy analyzes the morphology of the reconstructed pelvis model to determine the best fitting cup implant. The first planning strategy was compared to 3-D CT-based planning. Digitally reconstructed radiographs of THA patients with differently severe pathologies were used to evaluate the accuracy of predicting the cup size and position. Within a discrepancy of one cup size, the size was correctly identified in 100% of the cases for Crowe type I datasets and in 77.8% of the cases for Crowe type II, III, and IV datasets. The second planning strategy was analyzed with respect to the eventually implanted cup size. In seven patients, the estimated cup diameter was correct within one cup size, while the estimation for the remaining five patients differed by two cup sizes. While both planning strategies showed the same prediction rate with a discrepancy of one cup size (87.5%), the prediction of the exact cup size was increased for the statistical atlas-based strategy (56%) in contrast to the anatomically driven approach (37.5%). The proposed approach demonstrated the clinical validity of using 2-D/3-D reconstruction technique for cup planning.

  9. Development of a standardised cup anemometer suited to wind energy applications. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Dahlberg, J.Aa.; Gustavsson, J.; Ronsten, G. [Aeronautical Research Inst. of Sweden, Bromma (Sweden); Friis Pedersen, T.; Schmidt Paulsen, U. [Risoe National Laboratory, Roskilde (Denmark); Westermann, D. [German Wind Energy Inst., Wilhelmshaven (Germany)

    2002-05-01

    Errors associated with the measurements and interpretation of the measured wind speed are the major sources of uncertainties in power performance testing of wind turbines. Field comparisons of well calibrated anemometers of different types often show significant and not acceptable differences. The objective were to determine the optimum design for a cup anemometer which should be free from the design faults associated with all of the instruments currently commercially available. The objective were also to prepare a classification system for cup anemometers which will allow users of anemometry in the wind energy field to rank and select anemometers suited to specific required applications. The extensive experiments including tests in wind tunnels, of more than 500 anemometer configurations, fields tests and tests in laboratories together with the assessment and modelling work have helped to build up a thorough knowledge of the importance of different design parameters in terms of various behavioural effects. Influenced by trends from the international standardisation work, an early decision was made to focus on a vector, 3D, (angle-insensitive anemometer) cup-anemometer and to focus on conical cups since their sensitivity to vertical velocity components appeared to be less sensitive to the wind speed. The key measures taken to develop the new design consisted of an appropriate selection of the detailed design of the cup geometry's and mounting the cups at appropriate radius on a slender symmetric body. The development finally ended with an anemometer that gave a very good flat response within 1 % over the range from -45 deg to +35 deg and had a good linear calibration curve. Four prototypes of the anemometer optimised for flat response were produced. The flat response was also confirmed by field tests over the range {+-}20 deg. A patent application of the new anemometer was filed on the 6th of October 2000. By the time the project was initiated there was a

  10. Yeast CUP1 protects HeLa cells against copper-induced stress

    Energy Technology Data Exchange (ETDEWEB)

    Xie, X.X. [Department of Animal Sciences, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); Shanghai Key Laboratory of Veterinary Biotechnology, Shanghai (China); College of Biological and Environmental Engineering, Zhejiang University of Technology, Hangzhou (China); Ma, Y.F.; Wang, Q.S.; Chen, Z.L.; Liao, R.R.; Pan, Y.C. [Department of Animal Sciences, School of Agriculture and Biology, Shanghai Jiao Tong University, Shanghai (China); Shanghai Key Laboratory of Veterinary Biotechnology, Shanghai (China)

    2015-06-12

    As an essential trace element, copper can be toxic in mammalian cells when present in excess. Metallothioneins (MTs) are small, cysteine-rich proteins that avidly bind copper and thus play an important role in detoxification. YeastCUP1 is a member of the MT gene family. The aim of this study was to determine whether yeast CUP1 could bind copper effectively and protect cells against copper stress. In this study,CUP1 expression was determined by quantitative real-time PCR, and copper content was detected by inductively coupled plasma mass spectrometry. Production of intracellular reactive oxygen species (ROS) was evaluated using the 2',7'-dichlorofluorescein-diacetate (DCFH-DA) assay. Cellular viability was detected using the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, and the cell cycle distribution of CUP1 was analyzed by fluorescence-activated cell sorting. The data indicated that overexpression of yeast CUP1 in HeLa cells played a protective role against copper-induced stress, leading to increased cellular viability (P<0.05) and decreased ROS production (P<0.05). It was also observed that overexpression of yeast CUP1 reduced the percentage of G1 cells and increased the percentage of S cells, which suggested that it contributed to cell viability. We found that overexpression of yeast CUP1 protected HeLa cells against copper stress. These results offer useful data to elucidate the mechanism of the MT gene on copper metabolism in mammalian cells.

  11. [Clinical observation of post-herpetic neuralgia treated with TCM herbal cupping therapy].

    Science.gov (United States)

    Wu, Xi; Hu, Hui; Guo, Liang; Wang, Hui

    2013-02-01

    To compare the difference in the efficacy on post-herpetic neuralgia among TCM herbal cupping therapy, Chinese medicine thermal compressing therapy and mecobalamine. Fifty-seven cases were randomized into a TCM herbal cupping group, a thermal compressing group and a western medicine group, 19 cases in each one. The oral administration of ibuprofen was applied in every group. In the herbal cupping group, the bamboo cups soaked in the boiled Chinese herbal decoction were sucked on the most significant painful area. In the thermal compressing group, the towel soaked in the boiled Chinese herbal decoction was compressed on the most significant painful area. In the medication group, the muscular injection of mecobalamine was adopted. The treatment was given once a day, for 2 weeks totally in each group. SF-MPQ score and clinical efficacy before and after treatment were observed in each group. The remarkable effective rates were 78.9% (15/19), 36.8% (7/19) and 5.3% (1/19) in the TCM herbal cupping group, thermal compressing group and western medicine group separately. The efficacy in the TCM herbal cupping group was significantly superior to the thermal compressing group and western medicine group (all P cupping group was reduced more significantly as compared with the thermal compressing group and western medicine group (all P cupping therapy achieves the superior efficacy for post-herpetic neuralgia and relieves pain effectively of the patients, which is more advantageous than CM herbal thermal compressing therapy and Mecobalamine.

  12. Acetabular labral tears: contrast-enhanced MR imaging under continuous leg traction

    Energy Technology Data Exchange (ETDEWEB)

    Nishii, T. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Nakanishi, K. [Dept. of Radiology, Osaka Univ. Medical School, Suita (Japan); Sugano, N. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan); Naito, H. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Tamura, S. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Ochi, T. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan)

    1996-05-01

    The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning. (orig./MG)

  13. The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint.

    Science.gov (United States)

    Olson, S A; Bay, B K; Pollak, A N; Sharkey, N A; Lee, T

    1996-01-01

    The indications for open reduction and internal fixation of posterior wall acetabular fractures associated with a clinically stable hip joint are unclear. In previous work a large posterior wall defect (27% articular surface area) resulted in significant alteration of load transmission across the hip; specifically, there was a transition from evenly distributed loading along the acetabular articular surface to loading concentrated mainly in the superior portion of the articular surface during simulated single leg stance. However, the majority of posterior wall fractures involve a smaller amount of the articular surface. Posterior wall acetabular fractures not associated with instability of the hip are commonly treated nonoperatively. This practice does not account for the size of the posterior wall fracture. To study the biomechanical consequences of variably sized articular defects, a laboratory experiment was conducted evaluating three progressively larger posterior wall defects of the acetabulum during simulated single leg stance using superlow Fuji prescale film (Itochu International, New York): (a) 1/3 articular surface width through a 50 degrees arc along the posterior wall of the acetabulum, (b) 2/3, and (c) 3/3 articular width defects through the same 50 degrees arc along the posterior wall of the acetabulum. In the intact acetabulum, 48% of the total articular contact was located in the superior acetabulum. Twenty-eight percent of articular contact was in the anterior wall region of the acetabulum and 24% in the posterior wall region. After the 1/3 width posterior wall defect, 64% of the articular contact was located in the superior acetabulum (p = 0.0011). The 2/3 width posterior wall defect resulted in 71% of articular contact area being located in the superior acetabulum (p = 0.0006). After the 3/3 width posterior wall defect, 77% of articular contact was located in the superior acetabulum, significantly greater than the intact condition (p < 0

  14. Chronological changes in functional cup position at 10 years after total hip arthroplasty.

    Science.gov (United States)

    Okanoue, Yusuke; Ikeuchi, Masahiko; Takaya, Shogo; Izumi, Masashi; Aso, Koji; Kawakami, Teruhiko

    2017-09-19

    This study aims to clarify the chronological changes in functional cup position at a minimum follow-up of 10 years after total hip arthroplasty (THA), and to identify the risk factors influencing a significant difference in functional cup position during the postoperative follow-up period. We evaluated the chronological changes in functional cup position at a minimum follow-up of 10 years after THA in 58 patients with unilateral hip osteoarthritis. Radiographic cup position was measured on anteroposterior pelvic radiographs with the patient in the supine position, whereas functional cup position was recorded in the standing position. Radiographs were obtained before, 3 weeks after, and every 1 year after surgery. Functional cup anteversion (F-Ant) increased over time, and was found to have significantly increased at final follow-up compared to that at 3 weeks after surgery (p10° anteriorly. Preoperative posterior pelvic tilt in the standing position and vertebral fractures after THA were significant predictors of increasing functional cup anteversion. Although chronological changes in functional cup position do occur after THA, their magnitude is relatively low. However, posterior impingement is likely to occur, which may cause edge loading, wear of the polyethylene liner, and anterior dislocation of the hip. We believe that, for the combined anteversion technique, the safe zone should probably be 5°-10° narrower in patients predicted to show considerable changes in functional cup position compared with standard cases.

  15. Football business models: Why did Germany win the World Cup?

    DEFF Research Database (Denmark)

    Cortsen, Kenneth

    2016-01-01

    This article looks into the managerial aspects related to why and how Germany won the 2014 FIFA World Cup.......This article looks into the managerial aspects related to why and how Germany won the 2014 FIFA World Cup....

  16. Gene Expression Profiling of the Intact Dermal Sheath Cup of Human Hair Follicles.

    Science.gov (United States)

    Niiyama, Shiro; Ishimatsu-Tsuji, Yumiko; Nakazawa, Yosuke; Yoshida, Yuzo; Soma, Tsutomu; Ideta, Ritsuro; Mukai, Hideki; Kishimoto, Jiro

    2018-04-24

    Cells that constitute the dermal papillae of hair follicles might be derived from the dermal sheath, the peribulbar component of which is the dermal sheath cup. The dermal sheath cup is thought to include the progenitor cells of the dermal papillae and possesses hair inductive potential; however, it has not yet been well characterized. This study investigated the gene expression profile of the intact dermal sheath cup, and identified dermal sheath cup signature genes, including extracellular matrix components and BMP-binding molecules, as well as TGF-b1 as an upstream regulator. Among these, GREM2, a member of the BMP antagonists, was found by in situ hybridization to be highly specific to the dermal sheath cup, implying that GREM2 is a key molecule contributing to maintenance of the properties of the dermal sheath cup.

  17. Is Cup Positioning Challenged in Hips Previously Treated With Periacetabular Osteotomy?

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Stilling, Maiken; Søballe, Kjeld

    2014-01-01

    After periacetabular osteotomy (PAO), some patients develop osteoarthritis with need of a total hip arthroplasty (THA). We evaluated the outcome of THA following PAO and explored factors associated with inferior cup position and increased polyethylene wear. Follow-up were performed 4 to 10years...... after THA in 34 patients (38 hips) with previous PAO. Computer analysis evaluated cup position and wear rates. No patient had dislocations or revision surgery. Median scores were: Harris hip 96, Oxford hip 38 and WOMAC 78. Mean cup anteversion and abduction angles were 22(o) (range 7°-43°) and 45......° (range 28°-65°). Outliers of cup abduction were associated with persisting dysplasia (CE...

  18. Percutaneous Fixation of Anterior Column Acetabular Fracture in a Renal Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Halil Ceylan

    2013-01-01

    Full Text Available Renal transplantation, performed per million population, ranges from 30 to 60 in developed countries. The transplanted kidney is generally placed in iliac fossa; therefore the treatment procedure of the pelvic trauma in these patients should be selected carefully. The gold standard technique for the treatment of displaced acetabulum fractures is open reduction and internal fixation. Our patient had received a living-related-donor renal transplant due to chronic renal failure. In the second year of transplantation, she had been injured in a motor-vehicle accident, and radiographs showed a right acetabular anterior column fracture and left pubic rami fractures. The patient was treated with percutaneous fixation techniques and at one year of postoperative period there was no evidence of degenerative signs and the clinical outcome was good. Beside having the advantage of avoiding dissection through the iliac fossa by the standard ilioinguinal approach, percutaneous techniques, with shorter surgical time, decreasing soft tissue disruption, and the potential for early discharge from hospital might be ideal for a renal transplant recipient carrying a higher risk of infection. Percutaneous fixation of selected acetabular fractures in a renal transplant recipient would presumably have the potential to decrease the morbidity associated with traditional open surgical procedures.

  19. Acetabular reconstruction with human and bovine freeze-dried bone grafts and a reinforcement device

    Directory of Open Access Journals (Sweden)

    Ricardo Rosito

    2008-01-01

    Full Text Available BACKGROUND: This is a cohort trial (1997-2005 of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG and a reinforcement device. OBJECTIVE: To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS: There were two groups: I (n=26 receiving human grafts and II (n=25 receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d'Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn's et al. criteria for radiographic bone incorporation. RESULTS: No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424. CONCLUSION: The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty.

  20. Second-order motor planning in children: insights from a cup-manipulation-task.

    Science.gov (United States)

    Wunsch, Kathrin; Weiss, Daniel J; Schack, Thomas; Weigelt, Matthias

    2015-07-01

    The present study examined the development of anticipatory motor planning in an object manipulation task that has been used to successfully demonstrate motor planning in non-human primates (Weiss et al. in Psychol Sci 18:1063-1068, 2007). Seventy-five participants from four different age groups participated in a cup-manipulation task. One group was preschool children (average age of 5.1 years), two groups were primary school children (7.7 and 9.8 years old respectively) and the final group was comprised of adults. The experimental task entailed reaching for a plastic cup that was vertically suspended in an apparatus in either upright or inverted orientation, removing the cup by its stem and then retrieving a small toy from the inside of the cup. When the cup was inverted in the apparatus, evidence for anticipatory motor planning could be achieved by initially gripping the stem using an inverted (thumb-down) grip posture. We found that when the cup was in upright orientation, all participants reached for the cup using an upright grip (i.e., thumb-up posture). However, when the cup was inverted in the apparatus, only adults consistently used an inverted grasping posture, though the percentage of inverted grips among participants did increase with age. These results suggest a protracted development for anticipatory motor planning abilities in children. Surprisingly, the performance of adults on this task more closely resembles the performance of several nonhuman primate species as opposed to children even at approximately 10 years of age. We discuss how morphological constraints on flexibility may help account for these findings.

  1. The Sorption Behavior of Wood Studied by Means of an Improved Cup Method

    DEFF Research Database (Denmark)

    Eitelberger, Johannes; Svensson, Staffan

    2012-01-01

    background of transport processes, a special experimental test setup—the improved cup method—is presented. It allows for separation of sorption from other processes. In this test, a diffusion cup contains a thin specimen of wood, with one side facing outwards to a climate chamber and the opposite side facing...... inwards the cup. In contrast to the common cup method, the herein presented method uses a data logger for relative humidity and temperature placed inside the cup. The use of thin cross-cut specimens allows for explicit separation of the different processes occurring during transient moisture transport....... Mass changes were determined and relative humidity inside the cups was measured for eight specimens of Norway spruce with different specimen thicknesses. Relative humidity was increased in three uniform steps in the test chamber from 4.0 up to 76.5%. The results obtained with this special test setup...

  2. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    Science.gov (United States)

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  3. Importance of nuclear medicine diagnostics in CUP syndrome

    International Nuclear Information System (INIS)

    Winter, M.C.; Haberkorn, U.; Kratochwil, C.

    2014-01-01

    The diagnostic work-up in patients with carcinoma of unknown primary (CUP) syndrome is extensive, highly time-consuming and cost-intensive and ultimately often fails to detect a primary site. In this context chest X-ray and computed tomography (CT) have been used as standard imaging modalities in CUP syndrome. Since the introduction of positron emission tomography (PET) evaluation of tumor vitality has become possible. Furthermore, PET-CT hybrid scanners allow the combination of functional and morphological imaging. Several meta-analyses have reported an additional overall detection rate between 24.5 % and 44 % by either PET or PET-CT. Metastatic localization (cervical versus extracervical) did not influence the performance. The sensitivity was usually high (> 80 %) but specificity was moderate ranging from 68 % to 88 % at best. If mentioned, the results obtained by fluorodeoxyglucose (FDG)-PET significantly changed the clinical management in approximately one third of the patients studied. In a direct comparison with PET alone, PET-CT did not depict significantly more primary tumors but was able to reduce false positive findings. To determine the real additional value of PET-CT in the diagnosis of CUP syndrome large prospective studies with more uniform inclusion criteria are needed. Despite the capabilities of FDG-PET-CT there is as yet no evidence that a potentially improved diagnostic algorithm is translated into a better patient outcome. Nevertheless, FDG-PET-CT should be performed in all CUP patients where conventional imaging failed to detect a primary site or the results are equivocal. In CUP patients with cervical lymph node metastases PET-CT should be carried out prior to panendoscopy to reduce the number of false negative biopsies. (orig.) [de

  4. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization

    International Nuclear Information System (INIS)

    Hu Jing; Rovey, Joshua L.

    2011-01-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a ''double-humped'' energy distribution.

  5. Faraday cup with nanosecond response and adjustable impedance for fast electron beam characterization.

    Science.gov (United States)

    Hu, Jing; Rovey, Joshua L

    2011-07-01

    A movable Faraday cup design with simple structure and adjustable impedance is described in this work. This Faraday cup has external adjustable shunt resistance for self-biased measurement setup and 50 Ω characteristic impedance to match with 50 Ω standard BNC coaxial cable and vacuum feedthroughs for nanosecond-level pulse signal measurements. Adjustable shunt resistance allows self-biased measurements to be quickly acquired to determine the electron energy distribution function. The performance of the Faraday cup is validated by tests of response time and amplitude of output signal. When compared with a reference source, the percent difference of the Faraday cup signal fall time is less than 10% for fall times greater than 10 ns. The percent difference of the Faraday cup signal pulse width is below 6.7% for pulse widths greater than 10 ns. A pseudospark-generated electron beam is used to compare the amplitude of the Faraday cup signal with a calibrated F-70 commercial current transformer. The error of the Faraday cup output amplitude is below 10% for the 4-14 kV tested pseudospark voltages. The main benefit of this Faraday cup is demonstrated by adjusting the external shunt resistance and performing the self-biased method for obtaining the electron energy distribution function. Results from a 4 kV pseudospark discharge indicate a "double-humped" energy distribution.

  6. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    Science.gov (United States)

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.

  7. [Correlation analysis between residual displacement and hip function after reconstruction of acetabular fractures].

    Science.gov (United States)

    Ma, Kunlong; Fang, Yue; Luan, Fujun; Tu, Chongqi; Yang, Tianfu

    2012-03-01

    To investigate the relationships between residual displacement of weight-bearing and non weight-bearing zones (gap displacement and step displacement) and hip function by analyzing the CT images after reconstruction of acetabular fractures. The CT measures and clinical outcome were retrospectively analyzed from 48 patients with displaced acetabular fracture between June 2004 and June 2009. All patients were treated by open reduction and internal fixation, and were followed up 24 to 72 months (mean, 36 months); all fractures healed after operation. The residual displacement involved the weight-bearing zone in 30 cases (weight-bearing group), and involved the non weight-bearing zone in 18 cases (non weight-bearing group). The clinical outcomes were evaluated by Merle d'Aubigné-Postel criteria, and the reduction of articular surface by CT images, including the maximums of two indexes (gap displacement and step displacement). All the data were analyzed in accordance with the Spearman rank correlation coefficient analysis. There was strong negative correlation between the hip function and the residual displacement values in weight-bearing group (r(s) = -0.722, P = 0.001). But there was no correlation between the hip function and the residual displacement values in non weight-bearing group (r(s) = 0.481, P = 0.059). The results of clinical follow-up were similar to the correlation analysis results. In weight-bearing group, the hip function had strong negative correlation with step displacement (r(s) = 0.825, P = 0.002), but it had no correlation with gap displacement (r(s) = 0.577, P = 0.134). In patients with acetabular fracture, the hip function has correlation not only with the extent of the residual displacement but also with the location of the residual displacement, so the residual displacement of weight-bearing zone is a key factor to affect the hip function. In patients with residual displacement in weight-bearing zone, the bigger the step displacement is, the

  8. HIE-ISOLDE Faraday cups tested with ion beams at TRIUMF

    CERN Document Server

    Cantero, E D

    2014-01-01

    The future HIE-ISOLDE Faraday cups for both the intercryomodule regions and the HEBTs have been tested using 34S+7, 4He+, 23Na+6 and 20Ne+5 beams from the ISAC-II accelerator at TRIUMF. Their performance has been characterized together with the Faraday cups from REX-ISOLDE and those from ISAC-II. The measurements were done at E/A = 1.5, 2.85 and 5.5 MeV/u, with beam intensities in the range of 100 pA to 4 nA. The performance of these Faraday cups has been compared under the same beam conditions for different bias voltages up to -350 V. Within the experimental uncertainties, most of them coming from fluctuations in beam intensity, all devices showed similar results. Biasing the Faraday cup repeller ring to voltages of at least -60 V, the escape of secondary electrons was suppressed.

  9. Should money follow the patient: Financial implication for being the National Centre for the Treatment and Management of Pelvic and Acetabular Fractures in Ireland.

    LENUS (Irish Health Repository)

    Kelly, M E

    2013-03-13

    BACKGROUND: Pelvic and acetabular fractures are complex injuries requiring specialist treatment. Our institution is the National Centre for Treatment and Management of these injuries. AIM: To audit all referrals to our institution over a 6-month period and calculate the cost incurred by being the national referral centre. METHODS: Retrospective review of database, and subsequent allocation of Casemix points to assess total cost of treatment for each patient referred to our institution. RESULTS: 103 patients referred with pelvic or acetabular fracture for operative management. The furthest referral distance was 181miles. Over-all, the length of stay was 15.4 days. The average inclusive cost for a referral to our unit for operative management was €16,302. CONCLUSION: Pelvic and acetabular fractures are complex injuries that require specialist referral unit management. However for these units to remain sustainable money needs to "follow the patient".

  10. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Directory of Open Access Journals (Sweden)

    Turke Shawaf

    2018-05-01

    Full Text Available Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml size with narrow mouths were used. A manual pump (sucking cups was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusion: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  11. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Science.gov (United States)

    Shawaf, Turke; El-Deeb, Wael; Hussen, Jamal; Hendi, Mahmoud; Al-Bulushi, Shahab

    2018-01-01

    Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama) on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml) size with narrow mouths were used. A manual pump (sucking cups) was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusions: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  12. Effects of Titanium Mesh Surfaces-Coated with Hydroxyapatite/β-Tricalcium Phosphate Nanotubes on Acetabular Bone Defects in Rabbits

    Directory of Open Access Journals (Sweden)

    Thuy-Duong Thi Nguyen

    2017-07-01

    Full Text Available The management of severe acetabular bone defects in revision reconstructive orthopedic surgery is challenging. In this study, cyclic precalcification (CP treatment was used on both nanotube-surface Ti-mesh and a bone graft substitute for the acetabular defect model, and its effects were assessed in vitro and in vivo. Nanotube-Ti mesh coated with hydroxyapatite/β-tricalcium phosphate (HA/β-TCP was manufactured by an anodizing and a sintering method, respectively. An 8 mm diameter defect was created on each acetabulum of eight rabbits, then treated by grafting materials and covered by Ti meshes. At four and eight weeks, postoperatively, biopsies were performed for histomorphometric analyses. The newly-formed bone layers under cyclic precalcified anodized Ti (CP-AT meshes were superior with regard to the mineralized area at both four and eight weeks, as compared with that under untreated Ti meshes. Active bone regeneration at 2–4 weeks was stronger than at 6–8 weeks, particularly with treated biphasic ceramic (p < 0.05. CP improved the bioactivity of Ti meshes and biphasic grafting materials. Moreover, the precalcified nanotubular Ti meshes could enhance early contact bone formation on the mesh and, therefore, may reduce the collapse of Ti meshes into the defect, increasing the sufficiency of acetabular reconstruction. Finally, cyclic precalcification did not affect bone regeneration by biphasic grafting materials in vivo.

  13. Tool for cutting locking cups from guide tube mounting screws in a nuclear reactor

    International Nuclear Information System (INIS)

    Nee, J.D.; Hahn, J.J.

    1987-01-01

    This patent describes an apparatus for freeing a socket-head screw from a locking cup therefor in a reactor cavity, wherein the locking cup includes a fixed cylindrical side wall encircling the side surface of the screw head and an annular end wall overlying the outer end surface of the screw head. The apparatus consists of: frame means, cylindrical cutter means having a longitudinal axis and having a frustoconical cutting surface with an inner diameter less than the inner diameter of the locking cup side wall and with an outer diameter greater than the outer diameter of the locking cup side wall, and drive means carried by the frame means and coupled to the cutter means for effecting rotation thereof about the axis, the rotating cutter means are operable for severing the locking cup end wall from the locking cup side wall at the junction therebetween when the cutter means is moved against the locking cup substantially coaxially therewith

  14. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    Science.gov (United States)

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Directory of Open Access Journals (Sweden)

    Ahmed Almazroa

    2015-01-01

    Full Text Available Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed.

  16. Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey

    Science.gov (United States)

    Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan

    2015-01-01

    Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751

  17. Cup Blocks the Precocious Activation of the Orb Autoregulatory Loop

    Science.gov (United States)

    Wong, Li Chin; Schedl, Paul

    2011-01-01

    Translational regulation of localized mRNAs is essential for patterning and axes determination in many organisms. In the Drosophila ovary, the germline-specific Orb protein mediates the translational activation of a variety of mRNAs localized in the oocyte. One of the Orb target mRNAs is orb itself, and this autoregulatory activity ensures that Orb proteins specifically accumulate in the developing oocyte. Orb is an RNA-binding protein and is a member of the cytoplasmic polyadenylation element binding (CPEB) protein family. We report here that Cup forms a complex in vivo with Orb. We also show that cup negatively regulates orb and is required to block the precocious activation of the orb positive autoregulatory loop. In cup mutant ovaries, high levels of Orb accumulate in the nurse cells, leading to what appears to be a failure in oocyte specification as a number of oocyte markers inappropriately accumulate in nurse cells. In addition, while orb mRNA is mislocalized and destabilized, a longer poly(A) tail is maintained than in wild type ovaries. Analysis of Orb phosphoisoforms reveals that loss of cup leads to the accumulation of hyperphosphorylated Orb, suggesting that an important function of cup in orb-dependent mRNA localization pathways is to impede Orb activation. PMID:22164257

  18. Efficacy of cupping therapy in patients with the fibromyalgia syndrome-a randomised placebo controlled trial.

    Science.gov (United States)

    Lauche, Romy; Spitzer, Julia; Schwahn, Barbara; Ostermann, Thomas; Bernardy, Kathrin; Cramer, Holger; Dobos, Gustav; Langhorst, Jost

    2016-11-17

    This study aimed to test the efficacy of cupping therapy to improve symptoms and quality of life in patients diagnosed with the fibromyalgia syndrome. Participants were randomly assigned to cupping therapy, sham or usual care. Cupping was administered five times at twice weekly intervals on the upper and lower back. The primary outcome measure was pain intensity at day 18. Secondary outcomes included functional disability, quality of life, fatigue and sleep quality as well as pressure pain sensitivity, satisfaction and safety at day 18 and 6 months. Altogether 141 patients were included in this study (139 females, 55.8 ± 9.1 years). After 18 days patients reported significant less pain after cupping compared to usual care (difference -12.4; 95% CI: -18.9; -5.9, p cupping and sham cupping; and only minor side effects were observed. Despite cupping therapy being more effective than usual care to improve pain intensity and quality of life, effects of cupping therapy were small and comparable to those of a sham treatment, and as such cupping cannot be recommended for fibromyalgia at the current time.

  19. Management of knee osteoarthritis with cupping therapy.

    Science.gov (United States)

    Khan, Asim Ali; Jahangir, Umar; Urooj, Shaista

    2013-10-01

    The study aimed to evaluate the effect of cupping therapy at a clinical setting for knee osteoarthritis. A randomized, controlled clinical trial was conducted. Cupping was performed on 0-6(th) day; 9-11(th) day and 14(th) day, i.e., 11 sittings follow-up to determine longer term carryover of treatment effects utilizing both objective and subjective assessment. The assessment was performed before and after treatment spreading over a period of 15 days. The results of this study shows significant and better results in the overall management of knee osteoarthritis, particularly in relieving pain, edema, stiffness and disability. The efficacy of treatment with cupping therapy in relieving signs and symptoms of knee osteoarthritis is comparable to that of acetaminophen 650 mg thrice a day orally, in terms of analgesia, anti-inflammatory and resolution of edema with minimal and temporary side-effects like echymosis and blister formation while as control drug has greater side-effects particularly on upper gastrointestinal tract. It is recommended that further studies are conducted with a larger study samples and of longer duration.

  20. Management of knee osteoarthritis with cupping therapy

    Directory of Open Access Journals (Sweden)

    Asim Ali Khan

    2013-01-01

    Full Text Available The study aimed to evaluate the effect of cupping therapy at a clinical setting for knee osteoarthritis. A randomized, controlled clinical trial was conducted. Cupping was performed on 0-6 th day; 9-11 th day and 14 th day, i.e., 11 sittings follow-up to determine longer term carryover of treatment effects utilizing both objective and subjective assessment. The assessment was performed before and after treatment spreading over a period of 15 days. The results of this study shows significant and better results in the overall management of knee osteoarthritis, particularly in relieving pain, edema, stiffness and disability. The efficacy of treatment with cupping therapy in relieving signs and symptoms of knee osteoarthritis is comparable to that of acetaminophen 650 mg thrice a day orally, in terms of analgesia, anti-inflammatory and resolution of edema with minimal and temporary side-effects like echymosis and blister formation while as control drug has greater side-effects particularly on upper gastrointestinal tract. It is recommended that further studies are conducted with a larger study samples and of longer duration.

  1. Natural Remission of Major Periprosthetic Osteolysis following Total Hip Arthroplasty with Metal-on-Metal Bearings

    Directory of Open Access Journals (Sweden)

    Tatsuya Tamaki

    2017-01-01

    Full Text Available The natural course of adverse events following the use of metal-on-metal (MoM bearings in total hip arthroplasty (THA is not well known. In this article, we report the case of a patient with asymptomatic major acetabular osteolysis following MoM THA that diminished gradually without any surgical intervention. A 58-year-old male underwent one-stage bilateral MoM THA for bilateral osteoarthritis. Four years after THA, major acetabular osteolysis developed in his right hip without any local or systemic symptoms. The patient underwent a careful radiographic and clinical observation without any surgical intervention because he did not want to undergo revision surgery. The lesion gradually diminished after 7 years, and most of the osteolytic area was replaced by newly formed bone at 10 years. He continues to be followed with no evidence of cup loosening or migration. Our observation suggests that a periprosthetic osteolytic change related to the use of MoM bearings has the potential for natural remission.

  2. Distributed Active Traction Control System Applied to the RoboCup Middle Size League

    Directory of Open Access Journals (Sweden)

    José Almeida

    2013-10-01

    Full Text Available This work addresses the problem of traction control in mobile wheeled robots in the particular case of the RoboCup Middle Size League (MSL. The slip control problem is formulated using simple friction models for ISePorto Team Robots with a differential wheel configuration. Traction was also characterized experimentally in the MSL scenario for relevant game events. This work proposes a hierarchical traction control architecture which relies on local slip detection and control at each wheel, with relevant information being relayed to a higher level responsible for global robot motion control. A dedicated one axis control embedded hardware subsystem allowing complex local control, high frequency current sensing and odometric information procession was developed. This local axis control board is integrated in a distributed system using CAN bus communications. The slipping observer was implemented in the axis control hardware nodes integrated in the ISePorto Robots and was used to control and detect loss of traction. An external vision system was used to perform a qualitative analysis of the slip detection and observer performance results are presented.

  3. Compilation of LLNL CUP-2 Data

    Energy Technology Data Exchange (ETDEWEB)

    Eppich, G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kips, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lindvall, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-07-31

    The CUP-2 uranium ore concentrate (UOC) standard reference material, a powder, was produced at the Blind River uranium refinery of Eldorado Resources Ltd. in Canada in 1986. This material was produced as part of a joint effort by the Canadian Certified Reference Materials Project and the Canadian Uranium Producers Metallurgical Committee to develop a certified reference material for uranium concentration and the concentration of several impurity constituents. This standard was developed to satisfy the requirements of the UOC mining and milling industry, and was characterized with this purpose in mind. To produce CUP-2, approximately 25 kg of UOC derived from the Blind River uranium refinery was blended, homogenized, and assessed for homogeneity by X-ray fluorescence (XRF) analysis. The homogenized material was then packaged into bottles, containing 50 g of material each, and distributed for analysis to laboratories in 1986. The CUP-2 UOC standard was characterized by an interlaboratory analysis program involving eight member laboratories, six commercial laboratories, and three additional volunteer laboratories. Each laboratory provided five replicate results on up to 17 analytes, including total uranium concentration, and moisture content. The selection of analytical technique was left to each participating laboratory. Uranium was reported on an “as-received” basis; all other analytes (besides moisture content) were reported on a “dry-weight” basis. A bottle of 25g of CUP-2 UOC standard as described above was purchased by LLNL and characterized by the LLNL Nuclear Forensics Group. Non-destructive and destructive analytical techniques were applied to the UOC sample. Information obtained from short-term techniques such as photography, gamma spectrometry, and scanning electron microscopy were used to guide the performance of longer-term techniques such as ICP-MS. Some techniques, such as XRF and ICP-MS, provided complementary types of data. The results

  4. Rutting resistance of asphalt mixture with cup lumps modified binder

    Science.gov (United States)

    Shaffie, E.; Hanif, W. M. M. Wan; Arshad, A. K.; Hashim, W.

    2017-11-01

    Rutting is the most common pavement distress in pavement structures which occurs mainly due to several factors such as increasing of traffic volume, climatic conditions and also due to construction design errors. This failure reduced the service life of the pavement, reduced driver safety and increase cost of maintenance. Polymer Modified Binder has been observed for a long time in improving asphalt pavement performance. Research shows that the use of polymer in bituminous mix not only improve the resistance to rutting but also increase the life span of the pavement. This research evaluates the physical properties and rutting performance of dense graded Superpave-designed HMA mix. Two different types of dense graded Superpave HMA mix were developed consists of unmodified binder mix (UMB) and cup lumps rubber (liquid form) modified binder mix (CLMB). Natural rubber polymer modified binder was prepared from addition of 8 percent of cup lumps into binder. Results showed that all the mixes passed the Superpave volumetric properties criteria which indicate that these mixtures were good with respect to durability and flexibility. Furthermore, rutting results from APA rutting test was determined to evaluate the performance of these mixtures. The rutting result of CLMB demonstrates better resistance to rutting than those prepared using UMB mix. Addition of cup lumps rubber in asphalt mixture was found to be significant, where the cup lumps rubber has certainly improves the binder properties and enhanced its rutting resistance due to greater elasticity offered by the cup lumps rubber particles. It shows that the use of cup lumps rubber can significantly reduce the rut depth of asphalt mixture by 41% compared to the minimum rut depth obtained for the UMB mix. Therefore, it can be concluded that the cup lumps rubber is suitable to be used as a modifier to modified binder in order to enhance the properties of the binder and thus improves the performance of asphalt mixes.

  5. Porous metal revision shells for management of contained acetabular bone defects at a mean follow-up of six years: a comparison between up to 50% bleeding host bone contact and more than 50% contact.

    Science.gov (United States)

    Sternheim, A; Backstein, D; Kuzyk, P R T; Goshua, G; Berkovich, Y; Safir, O; Gross, A E

    2012-02-01

    We report the use of porous metal acetabular revision shells in the treatment of contained bone loss. The outcomes of 53 patients with ≤ 50% acetabular bleeding host bone contact were compared with a control group of 49 patients with > 50% to 85% bleeding host bone contact. All patients were treated with the same type of trabecular metal acetabular revision shell. The mean age at revision was 62.4 years (42 to 80) and the mean follow-up of both groups was 72.4 months (60 to 102). Clinical, radiological and functional outcomes were assessed. There were four (7.5%) mechanical failures in the ≤ 50% host bone contact group and no failures in the > 50% host bone contact group (p = 0.068). Out of both groups combined there were four infections (3.9%) and five recurrent dislocations (4.9%) with a stable acetabular component construct that were revised to a constrained liner. Given the complexity of the reconstructive challenge, porous metal revision acetabular shells show acceptable failure rates at five to ten years' follow-up in the setting of significant contained bone defects. This favourable outcome might be due to the improved initial stability achieved by a high coefficient of friction between the acetabular implant and the host bone, and the high porosity, which affords good bone ingrowth.

  6. RoboCup European Championship: Report of the Amsterdam 2000 event

    NARCIS (Netherlands)

    Groen, F.; van der Hoek, W.; Jonker, P.; Krose, B.; Spoelder, H.J.W.; Stramigioli, S.

    2001-01-01

    The local organizers of the RoboCup European Championship presents a brief, informal overview of this event with the aim to support organizers of future RoboCup events in the organization and coordination of such a rather complex tournament. The objective was to organize a low cost scientific event

  7. Investigation of turbine ventilator performance after added wind cup for room exhaust air applications

    Science.gov (United States)

    Harun, D.; Zulfadhli; Akhyar, H.

    2018-05-01

    The turbine ventilator is a wind turbine with a vertical axis that has a combined function of the wind turbine and a suction fan. In this study, the turbine ventilator modified by adding a wind cup on the top (cap) turbine ventilator. The purpose of this experiment is to investigated the effect of the addition of wind cup on the turbine ventilator. Turbine ventilator used is type v30 and wind cup with diameter 77 mm. The experiment was conducted using a triangular pentagon model space chamber which was cut off to place the ventilator turbine ventilation cup with a volume of 0.983 m3 (equivalent to 1 mm3). The results of this study indicate that at an average wind speed of 1.8 m/s, the rotation of the turbine produced without a wind cup is 60.6 rpm while with the addition of a wind cup in the turbine ventilator is 69 rpm. The average increase of rotation turbine after added win cup is 8.4 rpm and the efficiency improvement of turbine ventilator is 1.7 %.

  8. Fabrication of Faraday Cup Array for the Measurement of 2-Dimensional Proton Beam Profile

    International Nuclear Information System (INIS)

    Jung, Myunghwan; Kim, Bom Sok; Kim, Kyeryung

    2014-01-01

    It has an advantage of easy-to-use and possible to visually check, immediately; on the other hand, the measurement range is very limited. Another method is using the CCD camera-scintillator device such as p43 phosphor screen or chromox. A variety of faraday cup detectors have been recently introduced. The faraday cup is one of the powerful and popular tools for the measurement of beam current. By using several faraday cups in array geometry, it is possible to observe current distribution. In this study, we developed an external faraday cup array for the measure the beam current and profile at a KOMAC (Korea Multi-purpose Accelerator Complex) beam utilization facility. To measure the beam profile, before fabrication of faraday cup array, we use gafchromic film. By making the faraday cup array we were able to reduce the consumption of Gafchromic film and a more accurate diagnosis of the proton beam is possible. The use of faraday cup array, experiment using the proton beam is more reliable and confident

  9. Flow distortion on boom mounted cup anemometers

    DEFF Research Database (Denmark)

    Lindelöw, Per Jonas Petter; Friis Pedersen, Troels; Gottschall, Julia

    In this report we investigate on wind direction dependent errors in the measurement of the horizontal wind speed by boom mounted cup anemometers. The boom mounting on the studied lattice tower is performed according to IEC standard design rules, yet, larger deviations than predicted by flow models...... are observed. The errors on the measurements are likely caused by an underestimation of the flow distortions around the tower. In this paper an experimental method for deriving a correction formula and an in-field calibration is suggested. The method is based on measurements with two cup anemometers mounted...

  10. Radiotherapeutic concepts in cancer of unknown primary site; Strahlentherapeutische Konzepte beim CUP-Syndrom

    Energy Technology Data Exchange (ETDEWEB)

    Krug, D.; Debus, J.; Sterzing, F. [Universitaetsklinikum Heidelberg, Klinik fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany)

    2014-02-15

    The term cancer of unknown primary (CUP) encompasses a group of entities which differ to a great extent regarding etiology, prognosis and therapeutic management. The aim of the study was an elaboration of the role of radiotherapy in CUP syndrome. Systematic literature search and specification of the available treatment options. Radiotherapy is an integral part of interdisciplinary management approaches for patients with CUP in both curative and palliative situations. Radio-oncological techniques, such as intensity-modulated radiotherapy and stereotactic body radiotherapy increase the therapeutic window. Modern diagnostic modalities from radiology and nuclear medicine are the cornerstone of radiotherapeutic interventions, especially in terms of target volume definition and pretherapeutic staging. In the interdisciplinary setting radiation oncology offers the possibility of curative and often organ preserving approaches in patients with axillary and cervical CUP. In addition, improvement and preservation of quality of life can be achieved in patients with metastatic disease. Radiation oncology is a crucial component of the interdisciplinary management of patients with CUP. Therapeutic decisions in patients with CUP should be made in an interdisciplinary setting. (orig.) [German] Das Cancer-of-unknown-primary(CUP)-Syndrom fasst eine Gruppe von Erkrankungen zusammen, die durch eine ausgepraegte Heterogenitaet hinsichtlich Aetiologie, Therapie und Prognose gepraegt sind. Darstellung der Rolle der Strahlentherapie beim CUP-Syndrom. Systematische Literaturrecherche und Erlaeuterung der Behandlungsoptionen. Die Strahlentherapie ist beim CUP-Syndrom sowohl in adjuvanten und definitiven Therapiekonzepten wie auch in palliativer Intention etabliert. Technisch innovative Verfahren wie die intensitaetsmodulierte Radiotherapie und die stereotaktische Bestrahlung im Koerperstammbereich ermoeglichen eine Vergroesserung der therapeutischen Breite. Eine leistungsfaehige und moderne

  11. The Brazilian World Cup: too hot for soccer?

    Science.gov (United States)

    Lucena, Rebecca Luna; Steinke, Ercília Torres; Pacheco, Christina; Vieira, Lucas Lima; Betancour, Maribel Olaya; Steinke, Valdir Adilson

    2017-12-01

    The main objective of this research was to analyze the climate data for the host cities of the soccer World Cup held in Brazil in June and July 2014. A great deal of criticism was expressed about the Brazilian climate in the national and international press and media in the run-up to the competition, suggesting that the air temperature and relative air humidity would be the main adversaries of the soccer teams, especially those from Europe, during the competition. An analysis of the weather was done at the places and times of each of the 64 matches held. A human thermal comfort index was calculated (discomfort index (DI)) for each of the matches in order to discover the real climatic conditions in the host cities during the 2014 World Cup and their potential influence on the teams and human comfort in general. During the 2014 World Cup, only two matches were played at temperatures above 30 °C, representing a negligible percentage of the total number of matches. The air temperature for over half the matches (53%) was 20-25 °C. The results showed the air temperature and relative humidity data analyzed here both individually and in the form of an index indicate that the World Cup held in Brazil in 2014 did not put any of the players at risk due to extreme heat.

  12. Socio-economic impacts of the 2010 FIFA World Cup | Hermann ...

    African Journals Online (AJOL)

    Socio-economic impacts of the 2010 FIFA World Cup. ... Literature on the impacts of mega events on tourism is available but limited in number in terms of the impacts of mega events on local residents. This study analyses the post ... Keywords: Mega events, economic impacts, social impacts, World Cup, local community.

  13. 33 CFR 100.918 - Detroit APBA Gold Cup, Detroit, MI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Detroit APBA Gold Cup, Detroit, MI. 100.918 Section 100.918 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.918 Detroit APBA Gold Cup...

  14. Manipulating Tournaments in Cup and Round Robin Competitions

    OpenAIRE

    Russell, Tyrel; Walsh, Toby

    2009-01-01

    In sports competitions, teams can manipulate the result by, for instance, throwing games. We show that we can decide how to manipulate round robin and cup competitions, two of the most popular types of sporting competitions in polynomial time. In addition, we show that finding the minimal number of games that need to be thrown to manipulate the result can also be determined in polynomial time. Finally, we show that there are several different variations of standard cup competitions where mani...

  15. Solar Probe Cup: Laboratory Performance

    Science.gov (United States)

    Case, A. W.; Kasper, J. C.; Korreck, K. E.; Stevens, M. L.; Larson, D. E.; Wright, K. H., Jr.; Gallagher, D. L.; Whittlesey, P. L.

    2017-12-01

    The Solar Probe Cup (SPC) is a Faraday Cup instrument that will fly on the Paker Solar Probe (PSP) spacecraft, orbiting the Sun at as close as 9.86 solar radii. The SPC instrument is designed to measure the thermal solar wind plasma (protons, alphas, and electrons) that will be encountered throughout its close encounter with the Sun. Due to the solar wind flow being primarily radial, the SPC instrument is pointed directly at the Sun, resulting in an extreme thermal environment that must be tolerated throughout the primary data collection phase. Laboratory testing has been performed over the past 6 months to demonstrate the instrument's performance relative to its requirements, and to characterize the measurements over the expected thermal range. This presentation will demonstrate the performance of the instrument as measured in the lab, describe the operational configurations planned for flight, and discuss the data products that will be created.

  16. PERANAN METODE PENGOBATAN ISLAM CUPPING THERAPY DALAM PENURUNAN KADAR GLUKOSA DARAH

    Directory of Open Access Journals (Sweden)

    Cut Khairunnisa

    2016-06-01

    Full Text Available The Role of Islamic Treatment Method “Cupping Therapy” to Decrease Blood Glucose Levels. Cupping therapy has long been used by most Muslims and it has occupied as prominent position among therapeutic approaches.The proof of medical modern research lately have been supports expediency therapy which recommended by the prophet. Nowdays,many medical experts who know the benefits of cupping therapy in treating diseases. Diabetes melitus is a disease that is directly related to blood glucose levels. According to the International Diabetes Federation (IDF in 2013, there were 382 million people suffer from diabetes melitus worldwide and Indonesia as seventh ranks in the world. This study aims to determine the effect of cupping therapy on blood glucose levels in patients of Klinik Sehat dr. Abdurrahmân Medan in 2014. The Study used pre-experimental method with one group pre-test and post-test without a control group and sample took by randomization with a sample of 32 people. Based on the Wilcoxon test with á = 0.05 obtained p-value = 0.021 that means there were a significant differences in mean blood glucose levels before and after cupping therapy (p-value < á.

  17. Cupping therapy: A prudent remedy for a plethora of medical ailments.

    Science.gov (United States)

    Mehta, Piyush; Dhapte, Vividha

    2015-07-01

    Since ancient times, complementary and alternative medicine (CAM; bǔ chōng yǔ tì dài yī xué) have played an important role in human health and welfare. Many therapeutic approaches in healthcare outside the realm of conventional medicine persist in various parts of the world. There is considerable scientific and commercial potential in CAM, which needs to be explored precisely. Cupping therapy ( bá guàn liáo fǎ), one of the CAM, is practiced across the world. This therapy is believed to act by correcting imbalances in the internal bio field, such as by restoring the flow of "Qi (qì)". Cupping involves applying a heated cup to generate a partial vacuum that mobilizes the blood flow and promotes effective healing. This review outlines various tools and techniques of cupping therapy.

  18. The economic value of the 2010 Soccer World Cup

    Directory of Open Access Journals (Sweden)

    M. Saayman

    2008-12-01

    Full Text Available Purpose: The purpose of this article is to estimate the potential economic value of the 2010 Soccer World Cup for South Africa. Problem investigated: The Soccer World Cup (SWC is regarded as the largest sporting event to be hosted and South Africa is investing billions of Rand in the hosting thereof. Based on this the question that comes to mind is, what is the potential economic value of such an event? Previous research attempts to determine the economic value were limited in their focus on what should be included when economic modelling of events is conducted. Most of these studies were done by consultants on behalf of various government departments and consequently, the results of these attempts are criticised for their over-inflating and overestimations by various other researchers. Methodology: The literature review identified many aspects that need to be taken into account when modelling the economic impact of such an event together with aspects identified in the literature review. Lessons from the 2002 Korea/Japan and 2006 Germany Soccer World Cups were used as premise for our estimations. In this article, Computable General Equilibrium (CGE modelling is used to estimate the potential economic value. Findings: The results showed that the 2010 Soccer World Cup would in all probability have positive impacts on the economy of the country in terms of GDP growth and employment, with possible negative effects that include higher inflation and net export losses. Value of research: The value of this research lies in the approach that was followed firstly, by introducing lessons learned from previous World Cups as well as aspects not taken into consideration previously in economic modelling and secondly, by using CGE modelling in determining the economic value. Conclusion: The hosting of the 2010 Soccer World Cup is a major achievement not only for South Africa, but also for the rest of Africa, especially from a marketing point of view. From an

  19. Faraday cup for electron flux measurements on the microtron MT 25

    International Nuclear Information System (INIS)

    Vognar, M.; Simane, C.; Chvatil, D.

    2001-01-01

    The basic design criteria for construction of an evacuated Faraday cup for precise measurement of 5-25 MeV electron beam currents in air from a microtron are characterized. The homemade Faraday cup is described along with the electronic chain and its incorporation into the measuring beam line. The provisions applied to reduce backward electron escape are outlined. The current range was 10 -5 to 10 -10 A. The diameter of the Al entrance window of the Faraday cup was 1.8 cm, its area was 2.54 cm 2 and thickness 0.1 mm

  20. ACCUWIND - Accurate wind speed measurements in wind energy - Summary report[Cup and sonic anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Friis Pedersen, T.; Dahlberg, J.Aa.; Cuerva, A.; Mouzakis, F.; Busche, P.; Eecen, P.; Sanz-Andres, A.; Franchini, S.; Markkilde Petersen, S.

    2006-07-15

    The cup anemometer is at present the standard instrument used for mean wind speed measurement in wind energy. It is being applied in high numbers around the world for wind energy assessments. It is also applied exclusively for accredited power performance measurements for certification and verification purposes, and for purposes of optimisation in research and development. The revised IEC standard on power performance measurements has now included requirements for classification of cup anemometers. The basis for setting up such requirements of cup anemometers is two EU projects SITEPARIDEN and CLASSCUP from which the proposed classification method for cup anemometers was developed for the IEC standard. While cup anemometers at present are the standard anemometer being used for average wind speed measurements, sonic anemometers have been developed significantly over the last years, and prices have come down. The application of sonic anemometers may increase in wind energy if they prove to have comparable or better operational characteristics compared to cup anemometers, and if similar requirements to sonic anemometers are established as for cup anemometers. Sonic anemometers have historically been used by meteorologists for turbulence measurements, but have also found a role on wind turbine nacelles for wind speed and yaw control purposes. The report on cup and sonic anemometry deals with establishment of robustness in assessment and classification by focus on methods and procedures for analysis of characteristics of cup and sonic anemometers. The methods and procedures provide a platform, hopefully for use in meeting the requirements of the IEC standard on power performance measurements, as well as for development of improved instruments. (au)

  1. [Clinical application of moving cupping therapy based on skin reaction observation and syndrome differentiation].

    Science.gov (United States)

    Deng, Xiao-Lan; Chen, Bo; Chen, Ze-Lin

    2014-12-01

    The diagnostic evidence on clinical diseases and theoretic basis of moving cupping therapy were ex- plored in the paper. By the observation of the local reaction, such as skin appearance and color, the affected location, duration of sickness and nature of disease were judged. Different moving cupping methods were selected for different disorders. It was discovered that the property of syndromes should be recognized by the palpation on skin and muscle in the moving cupping therapy so that the pathogenesis and treating principle could be carefully determined. The moving cupping therapy is the important component of body surface therapy. Skin reaction observation and syndrome differentiation is the essential guidance of the moving cupping therapy.

  2. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Kristensen, L.; Jensen, G.; Hansen, A.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statisticalsignificance of the calibration expressions...

  3. Retinal and anterior eye compartments derive from a common progenitor pool in the avian optic cup

    Science.gov (United States)

    Venters, Sara J.; Cuenca, Paulina D.

    2011-01-01

    Purpose The optic cup is created through invagination of the optic vesicle. The morphogenetic rearrangement creates a double-layered cup, with a hinge (the Optic Cup Lip) where the epithelium bends back upon itself. Shortly after the optic cup forms, it is thought to be sub-divided into separate lineages: i) pigmented epithelium in the outer layer; ii) presumptive iris and ciliary body at the most anterior aspect of the inner layer; and iii) presumptive neural retina in the remainder of the inner layer. We test the native developmental potential of the anterior cup to determine if it normally contributes to the retina. Methods Vital dye and green fluorescent protein (GFP) expressing replication-incompetent retroviral vectors were used to label cells in the nascent optic cup and follow their direct progeny throughout development. Label was applied to either the optic cup lip (n=40), or to the domain just posterior to the lip (n=20). Retroviral labeling is a permanent lineage marker and enabled the analysis of advanced stages of development. Results Labeling within the optic cup gave rise to labeled progeny in the posterior optic cup that differentiated as neural retina (20 of 20). In contrast, labeling cells in the optic cup lip gave rise to progeny of labeled cells arrayed in a linear progression, from the lip into the neural retina (36 of 40). Label was retained in cells at the optic cup lip, regardless of age at examination. In older embryos, labeled progeny delaminated from the optic cup lip to differentiate as muscle of the pupillary margin. Conclusions The data show that the cells at the optic cup lip are a common progenitor population for pigmented epithelium, anterior eye tissues (ciliary body, iris, and pupillary muscle) and retinal neurons. The findings are supportive of an interpretation where the optic cup lip is a specialized niche containing a multipotent progenitor population. PMID:22219630

  4. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    Science.gov (United States)

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  5. Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs

    OpenAIRE

    Kneif, D.; Downing, M.; Ashcroft, G. P.; Gibson, P.; Knight, D.; Ledingham, W.; Hutchison, J.

    2005-01-01

    Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreem...

  6. CUP-1 Is a Novel Protein Involved in Dietary Cholesterol Uptake in Caenorhabditis elegans

    Science.gov (United States)

    Valdes, Victor J.; Athie, Alejandro; Salinas, Laura S.; Navarro, Rosa E.; Vaca, Luis

    2012-01-01

    Sterols transport and distribution are essential processes in all multicellular organisms. Survival of the nematode Caenorhabditis elegans depends on dietary absorption of sterols present in the environment. However the general mechanisms associated to sterol uptake in nematodes are poorly understood. In the present work we provide evidence showing that a previously uncharacterized transmembrane protein, designated Cholesterol Uptake Protein-1 (CUP-1), is involved in dietary cholesterol uptake in C. elegans. Animals lacking CUP-1 showed hypersensitivity to cholesterol limitation and were unable to uptake cholesterol. A CUP-1-GFP fusion protein colocalized with cholesterol-rich vesicles, endosomes and lysosomes as well as the plasma membrane. Additionally, by FRET imaging, a direct interaction was found between the cholesterol analog DHE and the transmembrane “cholesterol recognition/interaction amino acid consensus” (CRAC) motif present in C. elegans CUP-1. In-silico analysis identified two mammalian homologues of CUP-1. Most interestingly, CRAC motifs are conserved in mammalian CUP-1 homologous. Our results suggest a role of CUP-1 in cholesterol uptake in C. elegans and open up the possibility for the existence of a new class of proteins involved in sterol absorption in mammals. PMID:22479487

  7. 77 FR 28253 - Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI

    Science.gov (United States)

    2012-05-14

    ...-AA00 Safety Zone; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... navigable waters of the East Passage, Narragansett Bay, Rhode Island, during the America's Cup World Series... rulemaking (NPRM) entitled ``Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI...

  8. A confirmed case of toxic shock syndrome associated with the use of a menstrual cup.

    Science.gov (United States)

    Mitchell, Michael A; Bisch, Steve; Arntfield, Shannon; Hosseini-Moghaddam, Seyed M

    2015-01-01

    Menstrual cups have been reported to be an acceptable substitute for tampons. These flexible cups have also been reported to provide a sustainable solution to menstrual management, with modest cost savings and no significant health risk. The present article documents the first case of toxic shock syndrome associated with the use of a menstrual cup in a woman 37 years of age, using a menstrual cup for the first time. Toxic shock syndrome and the literature on menstrual cups is reviewed and a possible mechanism for the development of toxic shock syndrome in the patient is described.

  9. Elastoplastic cup model for cement-based materials

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    2010-03-01

    Full Text Available Based on experimental data obtained from triaxial tests and a hydrostatic test, a cup model was formulated. Two plastic mechanisms, respectively a deviatoric shearing and a pore collapse, are taken into account. This model also considers the influence of confining pressure. In this paper, the calibration of the model is detailed and numerical simulations of the main mechanical behavior of cement paste over a large range of stress are described, showing good agreement with experimental results. The case study shows that this cup model has extensive applicability for cement-based materials and other quasi-brittle and high-porosity materials in a complex stress state.

  10. Injuries among World Cup ski and snowboard athletes.

    Science.gov (United States)

    Flørenes, T W; Nordsletten, L; Heir, S; Bahr, R

    2012-02-01

    There is little information available on injuries to World Cup skiers and snowboarders. The aim of this study was to describe and compare the injury risk to World Cup athletes in alpine skiing, freestyle skiing, snowboarding, ski jumping, Nordic combined and cross country skiing. We performed retrospective interviews with the International Ski Federation (FIS) World Cup athletes from selected nations during the 2006-2007 and 2007-2008 winter seasons and recorded all acute injuries occurring during the seasons. We interviewed 2121 athletes and recorded 705 injuries. There were 520 (72%) time-loss injuries and 196 (28%) severe injuries (absence >28 days). In freestyle skiing, alpine skiing and snowboarding, there were 27.6, 29.8 and 37.8 time-loss and 14.4, 11.3 and 13.8 severe injuries per 100 athletes per season, respectively. In Nordic combined, ski jumping and cross country skiing, there were 15.8, 13.6 and 6.3 time-loss and 3.3, 5.6 and 0.7 severe injuries per 100 athletes per season, respectively. In conclusion about 1/3 of the World Cup alpine, freestyle and snowboard athletes sustain a time-loss injury each season, while the risk is low in the Nordic disciplines. A particular concern was the high proportion of severe injuries observed among alpine, freestyle and snowboard athletes, which is in contrast to most other sports. © 2010 John Wiley & Sons A/S.

  11. 76 FR 39289 - Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI

    Science.gov (United States)

    2011-07-06

    ...-AA08 Special Local Regulation; Detroit APBA Gold Cup, Detroit River, Detroit, MI AGENCY: Coast Guard... immediately after the Detroit APBA Gold Cup boat race. This special local regulation will establish... entry found in 33 CFR 100.918, Detroit APBA Gold Cup, Detroit, MI. Currently, the regulations located at...

  12. Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

    International Nuclear Information System (INIS)

    Beck, S.M.

    1975-04-01

    A mobile self-contained Faraday cup system for beam current measurments of nominal 600-MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 +- 0.95 eV for nominal 600-MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV

  13. Design, performance, and calculated error of a Faraday cup for absolute beam current measurements of 600-MeV protons

    International Nuclear Information System (INIS)

    Beck, S.M.

    1975-04-01

    A mobile self-contained Faraday cup system for beam current measurements of nominal 600 MeV protons was designed, constructed, and used at the NASA Space Radiation Effects Laboratory. The cup is of reentrant design with a length of 106.7 cm and an outside diameter of 20.32 cm. The inner diameter is 15.24 cm and the base thickness is 30.48 cm. The primary absorber is commercially available lead hermetically sealed in a 0.32-cm-thick copper jacket. Several possible systematic errors in using the cup are evaluated. The largest source of error arises from high-energy electrons which are ejected from the entrance window and enter the cup. A total systematic error of -0.83 percent is calculated to be the decrease from the true current value. From data obtained in calibrating helium-filled ion chambers with the Faraday cup, the mean energy required to produce one ion pair in helium is found to be 30.76 +- 0.95 eV for nominal 600 MeV protons. This value agrees well, within experimental error, with reported values of 29.9 eV and 30.2 eV. (auth)

  14. An aerodynamic analysis of recent FIFA world cup balls

    Science.gov (United States)

    Kiratidis, Adrian L.; Leinweber, Derek B.

    2018-05-01

    Drag and lift coefficients of recent FIFA world cup balls are examined. We fit a novel functional form to drag coefficient curves and in the absence of empirical data provide estimates of lift coefficient behaviour via a consideration of the physics of the boundary layer. Differences in both these coefficients for recent balls, which result from surface texture modification, can significantly alter trajectories. Numerical simulations are used to quantify the effect these changes have on the flight paths of various balls. Altitude and temperature variations at recent world cup events are also discussed. We conclude by quantifying the influence these variations have on the three most recent world cup balls, the Brazuca, the Jabulani and the Teamgeist. While our paper presents findings of interest to the professional sports scientist, it remains accessible to students at the undergraduate level.

  15. Facility arrangements and the environmental performance of disposable and reusable cups

    NARCIS (Netherlands)

    Potting, José; Harst-Wintraecken, van der Eugenie

    2015-01-01

    Purpose: This paper integrates two complementary life cycle assessment (LCA) studies with the aim to advice facility managers on the sustainable use of cups, either disposable or reusable. Study 1 compares three disposable cups, i.e., made from fossil-based polystyrene (PS), biobased and

  16. 77 FR 7025 - Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI

    Science.gov (United States)

    2012-02-10

    ...-AA00 Safety Zones; America's Cup World Series, East Passage, Narragansett Bay, RI AGENCY: Coast Guard... the America's Cup World Series sailing vessel racing event. This safety zone is intended to safeguard...'s Cup-class races on the waters of the East Passage, Narragansett Bay, Rhode Island. Vessels will be...

  17. Effects of wet-cupping on blood pressure in hypertensive patients: a randomized controlled trial.

    Science.gov (United States)

    Aleyeidi, Nouran A; Aseri, Khaled S; Matbouli, Shadia M; Sulaiamani, Albaraa A; Kobeisy, Sumayyah A

    2015-11-01

    Although cupping remains a popular treatment modality worldwide, its efficacy for most diseases, including hypertension, has not been scientifically evaluated. We aimed to determine the efficacy of wet-cupping for high blood pressure, and the incidence of the procedure's side effects in the intervention group. This is a randomized controlled trial conducted in the General Practice Department at King Abdulaziz University Hospital, Jeddah, Saudi Arabia, between May 2013 and February 2014. There were two groups (40 participants each): intervention group undergoing wet-cupping (hijama) in addition to conventional hypertension treatment, and a control group undergoing only conventional hypertension treatment. Three wet-cupping sessions were performed every other day. The mean systolic and diastolic blood pressures were measured using a validated automatic sphygmomanometer. The follow-up period was 8 weeks. Wet-cupping provided an immediate reduction of systolic blood pressure. After 4 weeks of follow-up, the mean systolic blood pressure in the intervention group was 8.4 mmHg less than in the control group (P=0.046). After 8 weeks, there were no significant differences in blood pressures between the intervention and control groups. In this study, wet-cupping did not result in any serious side effects. Wet-cupping therapy is effective for reducing systolic blood pressure in hypertensive patients for up to 4 weeks, without serious side effects. Wet-cupping should be considered as a complementary hypertension treatment, and further studies are needed. ClinicalTrials.gov Identifier NCT01987583.

  18. Automated detection of kinks from blood vessels for optic cup segmentation in retinal images

    Science.gov (United States)

    Wong, D. W. K.; Liu, J.; Lim, J. H.; Li, H.; Wong, T. Y.

    2009-02-01

    The accurate localization of the optic cup in retinal images is important to assess the cup to disc ratio (CDR) for glaucoma screening and management. Glaucoma is physiologically assessed by the increased excavation of the optic cup within the optic nerve head, also known as the optic disc. The CDR is thus an important indicator of risk and severity of glaucoma. In this paper, we propose a method of determining the cup boundary using non-stereographic retinal images by the automatic detection of a morphological feature within the optic disc known as kinks. Kinks are defined as the bendings of small vessels as they traverse from the disc to the cup, providing physiological validation for the cup boundary. To detect kinks, localized patches are first generated from a preliminary cup boundary obtained via level set. Features obtained using edge detection and wavelet transform are combined using a statistical approach rule to identify likely vessel edges. The kinks are then obtained automatically by analyzing the detected vessel edges for angular changes, and these kinks are subsequently used to obtain the cup boundary. A set of retinal images from the Singapore Eye Research Institute was obtained to assess the performance of the method, with each image being clinically graded for the CDR. From experiments, when kinks were used, the error on the CDR was reduced to less than 0.1 CDR units relative to the clinical CDR, which is within the intra-observer variability of 0.2 CDR units.

  19. Cupping therapy: A prudent remedy for a plethora of medical ailments

    Directory of Open Access Journals (Sweden)

    Piyush Mehta

    2015-07-01

    Full Text Available Since ancient times, complementary and alternative medicine (CAM; 補充與替代醫學 bǔ chōng yǔ tì dài yī xué have played an important role in human health and welfare. Many therapeutic approaches in healthcare outside the realm of conventional medicine persist in various parts of the world. There is considerable scientific and commercial potential in CAM, which needs to be explored precisely. Cupping therapy (拔罐療法 bá guàn liáo fǎ, one of the CAM, is practiced across the world. This therapy is believed to act by correcting imbalances in the internal bio field, such as by restoring the flow of “Qi (氣qì”. Cupping involves applying a heated cup to generate a partial vacuum that mobilizes the blood flow and promotes effective healing. This review outlines various tools and techniques of cupping therapy.

  20. Forecasting a winner for Malaysian Cup 2013 using soccer simulation model

    Science.gov (United States)

    Yusof, Muhammad Mat; Fauzee, Mohd Soffian Omar; Latif, Rozita Abdul

    2014-07-01

    This paper investigates through soccer simulation the calculation of the probability for each team winning Malaysia Cup 2013. Our methodology used here is we predict the outcomes of individual matches and then we simulate the Malaysia Cup 2013 tournament 5000 times. As match outcomes are always a matter of uncertainty, statistical model, in particular a double Poisson model is used to predict the number of goals scored and conceded for each team. Maximum likelihood estimation is use to measure the attacking strength and defensive weakness for each team. Based on our simulation result, LionXII has a higher probability in becoming the winner, followed by Selangor, ATM, JDT and Kelantan. Meanwhile, T-Team, Negeri Sembilan and Felda United have lower probabilities to win Malaysia Cup 2013. In summary, we find that the probability for each team becominga winner is small, indicating that the level of competitive balance in Malaysia Cup 2013 is quite high.

  1. Wear performance of neat and vitamin E blended highly cross-linked PE under severe conditions: The combined effect of accelerated ageing and third body particles during wear test.

    Science.gov (United States)

    Affatato, Saverio; De Mattia, Jonathan Salvatore; Bracco, Pierangiola; Pavoni, Eleonora; Taddei, Paola

    2016-12-01

    The objective of this study is to evaluate the effects of third-body particles on the in vitro wear behaviour of three different sets of polyethylene acetabular cups after prolonged testing in a hip simulator and accelerated ageing. Vitamin E-blended, cross-linked polyethylene (XLPE_VE), cross-linked polyethylene (XLPE) and conventional polyethylene (STD_PE) acetabular cups were simulator tested for two million cycles under severe conditions (i.e. by adding third-body particles to the bovine calf serum lubricant). Micro-Fourier Transform Infrared and micro-Raman spectroscopic analyses, differential scanning calorimetry, and crosslink density measurements were used to characterize the samples at a molecular level. The STD_PE cups had twice mass loss than the XLPE_VE components and four times than the XLPE samples; statistically significant differences were found between the mass losses of the three sets of cups. The observed wear trend was justified on the basis of the differences in cross-link density among the samples (XLPE>XLPE_VE>STD_PE). FTIR crystallinity profiles, bulk DSC crystallinity and surface micro-Raman crystallinity seemed to have a similar behaviour upon testing: all of them (as well as the all-trans and ortho-trans contents) revealed the most significant changes in XLPE and XLPE_VE samples. The more severe third-body wear testing conditions determined more noticeable changes in all spectroscopic markers with respect to previous tests. Unexpectedly, traces of bulk oxidation were found in both STD_PE (unirradiated) and XLPE (remelting-stabilized), which were expected to be stable to oxidation; on the contrary, XLPE_VE demonstrated a high oxidative stability in the present, highly demanding conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. [YANG's pricking-cupping therapy for knee osteoarthritis: a multi-center randomized controlled trial].

    Science.gov (United States)

    Wang, Bo; Liu, Xiru; Hu, Zhihai; Sun, Aijun; Ma, Yanwen; Chen Yingying; Zhang, Xuzhi; Liu, Meiling; Wang, Yi; Wang, Shuoshuo; Zhang, Yunjia; Li, Yijing; Shen, Weidong

    2016-02-01

    To evaluate the clinical efficacy of YANG's pricking-cupping therapy for knee osteoar thritis (KOA). Methods This was a multi-center randomized parallel controlled trial. One hundred and seventy one patients with KOA were randomly allocated to a pricking-cupping group (89 cases) and a conventional acu puncture group (82 cases). Neixiyan (EX-LE 4), Dubi (ST 35) and ashi points were selected in the two groups. Patients in the pricking-cupping group were treated with YANG's pricking-cupping therapy; the seven-star needles were used to perform pricking at acupoints, then cupping was used until slight bleeding was observed. Patients in the conventional acupuncture group were treated with semi-standardized filiform needle therapy. The treatment was given for 4 weeks (from a minimum of 5 times to a maximum of 10 times). The follow-up visit was 4 weeks. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the visual analogue scale (VAS) were adopted for the efficacy assessments. The pain score, stiffness score, physical function score and total score of WOMAC were all reduced after 4-week treatment and during follow-up visit in the two groups (all P0. 05), each score and total score of WOMAC in the pricking-cupping group were lower than those in the conventional acupuncture group after 4-week treatment and during follow-up visit (Pcupping group were lower than those in the conventional acupuncture group after 4-week treatment and during follow-up visit (P cupping and conventional acupuncture therapy can both significantly improve knee joint pain and function in patients with KOA, which are relatively safe. The pricking cupping therapy is superior to conventional acupuncture with the identical selection of acupoints.

  3. Diagnose of large area electron beam with faraday cup

    International Nuclear Information System (INIS)

    Tang Ying; Qian Hang; Yi Aiping; Huang Xin; Yu Li; Liu Jingru; Su Jiancang; Ding Zhenjie; Ding Yongzhong; Yu Jianguo

    2008-01-01

    In the experiment of gas laser pumped by electron beam, large area uniform electron beam is important to generate high efficiency laser output. This paper introduces Faraday cup is used in the diagnose experiment on the uniformity of large area e-beam generated by SPG-200 pulsed power generator. Construction of Faraday cup and the results of calibration are presented in detail. The uniformity of velvet emission is given, and the results of experiment are analyzed. (authors)

  4. A novel cupping-assisted plasma treatment for skin disinfection

    Science.gov (United States)

    Xiong, Zilan; Graves, David B.

    2017-02-01

    A novel plasma treatment method/plasma source called cupping-assisted plasma treatment/source for skin disinfection is introduced. The idea combines ancient Chinese ‘cupping’ technology with plasma sources to generate active plasma inside an isolated, pressure-controlled chamber attached to the skin. Advantages of lower pressure include reducing the threshold voltage for plasma ignition and improving the spatial uniformity of the plasma treatment. In addition, with reduced pressure inside the cup, skin pore permeability might be increased and it improves attachment of the plasma device to the skin. Moreover, at a given pressure, plasma-generated active species are restricted inside the cup, raising local reactive species concentration and enhancing the measured surface disinfection rate. A surface micro-discharge (SMD) device is used as an example of a working plasma source. We report discharge characteristics and disinfection efficiency as a function of pressure and applied voltage.

  5. Stability of the Giliberty bipolar hip: report of three cases.

    Science.gov (United States)

    Langan, P; Weiss, C A

    1978-01-01

    The Giliberty Bipolar Hip Prosthesis consists of an unbonded acetabular cup which snap-fits over the head of the femoral prosthesis. Because of the free movement permitted at the cup-pelvic junction as well as at the snap-fit interface, there has been a great deal of concern over the potential for dislocation. Three patients in whom this unit was implanted sustained significant skeletal trauma subsequent to surgery. None of them dislocated. In each case the prosthetic head was known to be in a relatively vertical orientation with respect to the transverse axis of the pelvis prior to the injury. In 2 of the 3 cases radiographically identifiable movement of the cup was present before and after the injury. These observations suggest that the persistently mobile, vertically positioned unbonded cup remain stable despite the stress of significant trauma. It is probable that the potential for cup movement, even where on the X-ray it appears to have stopped, acts as a safety valve in absorbing force that might otherwise dislocate the hip or cause fractures of the femur or the pelvis.

  6. Optimization of a Short Faraday Cup for Low-Energy Ions using Numerical Simulations

    CERN Document Server

    Bravin, E; Garcia Sosa, A; Welsch, CP

    2014-01-01

    ISOLDE, the heavy-ion facility at CERN is undergoing a major upgrade with the installation of a superconducting LINAC that will allow post-acceleration of ion beams up to 10 MeV/u. In this framework, customized beam diagnostics are being developed in order to fulfill the design requirements as well as to fit in the compact diagnostic boxes foreseen. The main detector of this system is a compact Faraday cup that will measure beam intensities in the range of 1 pA to 1 nA. In this contribution, simulation results of electrostatic fields and particle tracking are detailed for different Faraday cup prototypes taking into account the energy spectrum and angle of emission of the ion-induced secondary electrons.

  7. Distributed active traction control system applied to the RoboCup middle size league

    OpenAIRE

    Almeida, José; Dias, André; Sequeira, João; Martins, Alfredo; Silva, Eduardo

    2013-01-01

    This work addresses the problem of traction control in mobile wheeled robots in the particular case of the RoboCup Middle Size League (MSL). The slip control problem is formulated using simple friction models for ISePorto Team robots with a differential wheel configuration. Traction was also characterized experimentally in the MSL scenario for relevant game events. This work proposes a hierarchical traction control architecture which relies in local slip detection and con...

  8. Evaluation of a menstrual cup to collect shed endometrium for in vitro studies.

    Science.gov (United States)

    Koks, C A; Dunselman, G A; de Goeij, A F; Arends, J W; Evers, J L

    1997-09-01

    To evaluate whether a menstrual cup is a suitable instrument to collect antegradely shed endometrium for in vitro studies. A prospective, descriptive, cell biological and immunohistochemical study. Tertiary care university medical center. Nine female volunteers with regular cycles. Menstrual effluent was collected with a menstrual cup. Experience with the menstrual cup was described. Cytospin specimens, frozen sections, and cultures were prepared from the obtained menstrual tissue. The acceptability of the menstrual cup. The presence and viability of endometrial tissue was evaluated using immunohistochemical staining and culture outcome. All women except one described the menstrual cup as acceptable. Menstrual effluent contained single cells, clumps of cells, and glandlike structures. After 5 days of culture, the endometrial tissue appeared to be viable. Immunohistochemistry showed positive staining for vimentin in most cytospin specimens, in all cryostat specimens, and in 10 of 17 cultures. Cytokeratin 18 stained most cytospin specimens, all cryostat specimens, and 10 of 17 cultures. Positive staining for BW495/36 was observed in most cytospin specimens, all cryostat specimens, and 11 of 17 cultures. A menstrual cup in an acceptable instrument to collect antegradely shed menstrual tissue. Menstruum contains viable endometrial tissue that can be used for in vitro studies of endometrium and endometriosis.

  9. dlx and sp6-9 Control optic cup regeneration in a prototypic eye.

    Directory of Open Access Journals (Sweden)

    Sylvain W Lapan

    2011-08-01

    Full Text Available Optic cups are a structural feature of diverse eyes, from simple pit eyes to camera eyes of vertebrates and cephalopods. We used the planarian prototypic eye as a model to study the genetic control of optic cup formation and regeneration. We identified two genes encoding transcription factors, sp6-9 and dlx, that were expressed in the eye specifically in the optic cup and not the photoreceptor neurons. RNAi of these genes prevented formation of visible optic cups during regeneration. Planarian regeneration requires an adult proliferative cell population with stem cell-like properties called the neoblasts. We found that optic cup formation occurred only after migration of progressively differentiating progenitor cells from the neoblast population. The eye regeneration defect caused by dlx and sp6-9 RNAi can be explained by a failure to generate these early optic cup progenitors. Dlx and Sp6-9 genes function as a module during the development of diverse animal appendages, including vertebrate and insect limbs. Our work reveals a novel function for this gene pair in the development of a fundamental eye component, and it utilizes these genes to demonstrate a mechanism for total organ regeneration in which extensive cell movement separates new cell specification from organ morphogenesis.

  10. Vacuum delivery at The Maternity Hospital Kuala Lumpur: a comparison of metal and silicone cups.

    Science.gov (United States)

    Lee, H Y; Subramaniam, N; Nordin, M M

    1996-02-01

    To compare the advantages and disadvantages of the New Bird metal cups and silicone cups in terms of maternal and foetal outcome. To study the adverse effects and factors associated with failed vacuum deliveries. A prospective randomised study of all vacuum deliveries from 1 December 1991 to 31 April 1992. The Hanshin electrical vacuum pump was used. A large obstetric unit-The Maternity Hospital Kuala Lumpur (MHKL). Seventy-two consecutive patients where vacuum deliveries were indicated. Forty had metal and 32 had silicone cups. Another 7 vacuum deliveries using the manual vacuum pump were excluded. Success rate of vaginal delivery, birth canal injuries, post-partum haemorrhage, duration of hospital stay, Apgar score, foetal injuries (scalp-ecchymosis, haematomas) neonatal jaundice, the rate of special care nursery (SCN) admission and neonatal mortality rate. Failure to deliver with silicone cups alone was 21.9% compared to 10% for metal cups alone. Material morbidities and serious foetal scalp injuries were almost the same in both cups. However, minor foetal scalp injuries were significantly lower with silicone cups. Maternal height and baby's weight had no independent predictive values for successful vacuum delivery. When the foetal head was palpable per abdomen, the failure rate was 54.5% compared to 8.2% when it was not. Failed vacuum deliveries were associated with increased maternal and foetal morbidities. Silicone cups and metal cups can be equally dangerous to the baby. Although our sample size was small, we recommend that vacuum delivery be avoided if the foetal head is palpable per abdomen.

  11. Enhancement of optic cup detection through an improved vessel kink detection framework

    Science.gov (United States)

    Wong, Damon W. K.; Liu, Jiang; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Wong, Tien Yin

    2010-03-01

    Glaucoma is a leading cause of blindness. The presence and extent of progression of glaucoma can be determined if the optic cup can be accurately segmented from retinal images. In this paper, we present a framework which improves the detection of the optic cup. First, a region of interest is obtained from the retinal fundus image, and a pallor-based preliminary cup contour estimate is determined. Patches are then extracted from the ROI along this contour. To improve the usability of the patches, adaptive methods are introduced to ensure the patches are within the optic disc and to minimize redundant information. The patches are then analyzed for vessels by an edge transform which generates pixel segments of likely vessel candidates. Wavelet, color and gradient information are used as input features for a SVM model to classify the candidates as vessel or non-vessel. Subsequently, a rigourous non-parametric method is adopted in which a bi-stage multi-resolution approach is used to probe and localize the location of kinks along the vessels. Finally, contenxtual information is used to fuse pallor and kink information to obtain an enhanced optic cup segmentation. Using a batch of 21 images obtained from the Singapore Eye Research Institute, the new method results in a 12.64% reduction in the average overlap error against a pallor only cup, indicating viable improvements in the segmentation and supporting the use of kinks for optic cup detection.

  12. 77 FR 20846 - Certain Food Containers, Cups, Plates, Cutlery, and Related Items and Packaging Thereof...

    Science.gov (United States)

    2012-04-06

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-835] Certain Food Containers, Cups, Plates... the sale within the United States after importation of certain food containers, cups, plates, cutlery... importation, or the sale within the United States after importation of certain food containers, cups, plates...

  13. The Study of a Beam Profile Monitor based on Faraday Cup Array

    Energy Technology Data Exchange (ETDEWEB)

    Park, K. M.; Park, S. H.; Kim, S. G.; Kwon, H. J.; Cho, Y. S. [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The metal can then be discharged to measure a small current equivalent to the number of impinging ions. The beam current can be measured and used to determine the number of ions or electrons hitting the cup. Recently, beam profile monitor (BPM) based on Faraday cup array (FCA), which represented beam position through the spatial and temporal distribution of the beam current, has been studied due to advantages of measure of wide-range ion beam current. FCA system is divided into a FC, an electrical circuit and display parts. We have studied FCA to monitor beam profile on an electrostatic accelerator with wide-range ion current. In this paper, we represented basic characteristics and designs for the fabricated FCA. FCA system, which consisted of FC system, electronic readout system, and output display, was suggested to measure ion beam current, efficiently. FC system consisted of a collimator, suppressor, tiny FC, insulator frame, and circuit board divided into elec PCB, cap PCB, and con PCB. FC size was 4 mm diameters and FCA system was considered as 8 x 8 array and whole size of 8 x 8 mm''2. FCA system was set-up in vacuum chamber and an integrator and output display parts were formed out of chamber to minimize number of feed-through.

  14. ACCUWIND - Classification of five cup anemometers according to IEC 61400-12-1

    DEFF Research Database (Denmark)

    Friis Pedersen, Troels; Dahlberg, J.-Å.; Busche, P.

    2006-01-01

    The characteristics of five cup anemometers were investigated in detail, and data are presented in figures and tables. The characteristics include: normal wind tunnel calibrations; angular response measurements at 5, 8 and 11m/s; torque coefficient curvemeasurements from combined tilt and ramp......-gust tests, torque coefficient curve measurements for non-tilted conditions; rotor inertia measurements and measurements of friction of bearings at temperatures -10°C to 40°C. The characteristics are fitted to twodifferent time domain cup anemometer models, and simulations of the cup anemometers are made...

  15. Management and marketing of sporting events: Nike Premier Cup Project

    OpenAIRE

    Nedbal, Jakub

    2008-01-01

    Title: Management and marketing ofsporting events: Nike Premier Cup project Points of thesis: Publish the Nike Premier Cup promotion campaign project and point out improvement possibilities for upcoming years based on analysis ofpast and present state. Methods: Data will be obtained by interview, observation, description analysis and SWOT analysis Results: Promotion campaign, improvement possibilities, final day schedule Keywords: SWOT analysis, promotion, management, marketing, Nike Premier ...

  16. [Effect of cupping on hemodynamic levels in the regional sucked tissues in patients with lumbago].

    Science.gov (United States)

    Tang, Xiao; Xiao, Xue-Hua; Zhang, Guo-Qing

    2012-10-01

    To observe hemodynamic changes in the local sucked tissue of lower back undergoing negative pressure after cupping in patients with lumbago. Twenty-two lumbago outpatients were recruited in the present study and 32 sucked tissues accepted measurements. The cupping was applied to the tenderpoint of the patients' lower back for 10 min by using a glass-mug (5 cm in diameter). Hemodynamic indexes [peak systolic velocity (PSV), end-diastolic velocity (EDV) and resistance index (RI)] of the sucked skin and subcutaneous tissues at the lower back were detected before and after cupping by using a color Doppler flow imaging. After cupping intervention at the lower back, the PSV [(14.2 +/- 1.8) cm/s] and EDV [(5.5 +/- 0.7) cm/s] levels were increased significantly in comparison with those [(5.9 +/- 0.9) and (1.9 +/- 0.3) cm/s] before cupping (P cupping (0.61 +/- 0.05 vs 0.68 +/- 0.06, P Cupping therapy can increase the peak systolic velocity and end-diastolic velocity and lower vascular resistance of the subcutaneous arterioles in the regional tissue, which may contribute to its effect in relieving lumbago.

  17. The age grading and the Chen-Ruan cup product

    DEFF Research Database (Denmark)

    A. Hepworth, Richard

    2010-01-01

    We prove that the obstruction bundle used to define the cup-product in Chen-Ruan cohomology is determined by the so-called `age grading' or `degree-shifting numbers'. Indeed, the obstruction bundle can be directly computed using the age grading. We obtain a Kunneth Theorem for Chen-Ruan cohomology...... as a direct consequence of an elementary property of the age grading, and explain how several other results - including associativity of the cup-product - can be proved in a similar way....

  18. 33 CFR 100.916 - Chris Craft Silver Cup Races, Algonac, MI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Chris Craft Silver Cup Races, Algonac, MI. 100.916 Section 100.916 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.916 Chris Craft Silver Cup...

  19. Validation of 3D sonic-anemometer against cup anemometer response

    DEFF Research Database (Denmark)

    Hansen, Kurt Schaldemose; Larsen, Gunner Chr.; Courtney, Michael

    2004-01-01

    Determination and validation of wind turbine power curves traditionally rely on single point wind speed measurements recorded with a calibrated cup-anemometer. The power curve verification process, which is typically performed in different terrain types, does not always result in satisfactory...... agreement between measures- and predicted power curves. The observed disagreement is premarily believed to relate to the cup-anemometers being sensitive to tilted flow i.e. that the measurement of the horizontal flow component is sensible to flow in a plane perpendicular to the horizontal plane. Furthermore......, the limited cup-anemometer response due to high turbulence can explain some of the diviations. The present paper investigates this problem, by analysing full-scale time series data extracted from "Database on Wind Characteristics" (http://www.winddata.com/), which represents a wide range of sites. Basically...

  20. A Case Report of Unilateral Severe Visual Loss Along with Bilateral Optic Disc Cupping Secondary to Metastatic Brain Tumor

    Directory of Open Access Journals (Sweden)

    M Mahdavi

    2006-07-01

    Full Text Available Purpose: To report a case of unilateral severe visual loss and bilateral optic disc cupping secondary to brain metastasis of bronchogenic carcinoma Patient and findings: A 48 year-old woman presented with severe visual loss of left eye without redness or pain or any systemic findings .Clinical findings included decreased visual acuity of left eye to 4 m CF and (+3 positive Marcus-Gunn reflex .There was asymmetric optic disc cupping associated with visual field defect in left eye The neurologic investigations showed a secondary metastatic tumor in the brain from bronchogenic carcinoma. Conclusion: Before making a diagnosis of normal -tension glaucoma in asymmetric optic disc cupping and normal intraocular pressure, ophthalmologists should rule out neurologic defects and brain tumors.