WorldWideScience

Sample records for accumulation chamber method

  1. Chambers versus Relaxed Eddy Accumulation: an intercomparison study of two methods for short-term measurements of biogenic CO2 fluxes

    Science.gov (United States)

    Jasek, Alina; Zimnoch, Miroslaw; Gorczyca, Zbigniew; Chmura, Lukasz; Necki, Jaroslaw

    2014-05-01

    The presented work is a part of comprehensive study aimed at thorough characterization of carbon cycle in the urban environment of Krakow, southern Poland. In the framework of this study two independent methods were employed to quantify biogenic CO2 flux in the city: (i) closed chambers, and (ii) Relaxed Eddy Accumulation (REA). The results of a three-day intensive intercomparison campaign performed in July 2013 and utilizing both measurement methods are reported here. The chamber method is a widely used approach for measurements of gas exchange between the soil and the atmosphere. The system implemented in this study consisted of a single chamber operating in a closed-dynamic mode, combined with Vaisala CarboCAP infrared CO2 sensor in a mobile setup. An alternative flux measurement method, covering larger area is represented by REA, which is a modification of the eddy covariance method. It consists of a 3D anemometer (Gill Windmaster Pro) and the system collecting updraft and downdraft samples to 5-litre Tedlar bags. The CO2 mixing ratios in the collected samples are measured by Picarro G2101i analyzer. The setup consists of two sets of bags so that the sampling can be performed continuously with 15-min temporal resolution. A 48-hectares open meadow located close the city center was chosen as a test site for comparison of the two methods of CO2 flux measurements outlined above. In the middle of the meadow a 3-metre high tripod was installed with the anemometer and REA inlet system. For a period of 46 hours the system was measuring net CO2 flux from the surrounding area. A meteorological conditions and intensity of photosynthetically active radiation (PAR) were also recorded. In the same time, CO2 flux from several points around the REA inlet was measured with the chamber system, resulting in 93 values for both respiration and net CO2 flux. Chamber results show rather homogenous distribution of the soil CO2 flux (the mean value equal to 40.9 ± 2.2 mmol/m2h), with

  2. Method of controlling weld chamber purge and cover gas atmosphere

    International Nuclear Information System (INIS)

    Yeo, D.

    1992-01-01

    A method of controlling the gas atmosphere in a welding chamber includes detecting the absence of a fuel rod from the welding chamber and, in response thereto, initiating the supplying of a flow of argon gas to the chamber to purge air therefrom. Further, the method includes detecting the entry of a fuel rod in the welding chamber and, in response thereto, terminating the supplying of the flow of argon gas to the chamber and initiating the supplying of a flow of helium gas to the chamber to purge argon gas therefrom and displace the argon gas in the chamber. Also, the method includes detecting the withdrawal of the fuel rod from the welding chamber and, in response thereto, terminating the supplying of the flow of helium gas to the chamber and initiating the supplying of argon to the chamber to purge the air therefrom. The method also includes detecting the initiation of a weld cycle and, in response thereto, momentarily supplying a flow of argon gas to the welding electrode tip for initiating the welding arc. (Author)

  3. ON THE ANALYSIS OF BUBBLE CHAMBER TRACKS

    International Nuclear Information System (INIS)

    Bradner, H.; Solmitz, F.

    1958-01-01

    Since its invention by Glaser in 1953, the bubble chamber has become a most valuable tool in high-energy physics. It combines a number of advantages of various older methods of particle detection: it offers high spatial resolution, rapid accumulation of data, some time resolution, and some choice of the nucleus whose interaction one wants to study (bubble chambers have been made to operate with a large number of different liquids, including H 2 , D 2 , He, Xe, and several hydrocarbons). In order to exploit the advantages of spatial resolution and rapid data accumulation, high-speed high-precision analysis procedures must be developed. In this article they discuss some of the problems posed by such analysis. The discussion is based largely on experience gained in performing hydrogen bubble chamber experiments with the University of California's Bevatron (6-Bev proton synchrotron)

  4. Genetic parameters of methane emissions determined using portable accumulation chambers in lambs and ewes grazing pasture and genetic correlations with emissions determined in respiration chambers.

    Science.gov (United States)

    Jonker, A; Hickey, S M; Rowe, S J; Janssen, P H; Shackell, G; Elmes, S; Bain, W E; Wing, J; Greer, G J; Bryson, B; MacLean, S; Dodds, K G; Pinares-Patiño, C S; Young, E A; Knowler, K; Pickering, N K; McEwan, J C

    2018-05-07

    Methane (CH4) emission traits were previously found to be heritable and repeatable in sheep fed alfalfa pellets in respiration chambers (RC). More rapid screening methods are, however, required to increase genetic progress and to provide a cost effective method to the farming industry for maintaining the generation of breeding values in the future. The objective of the current study was to determine CH4 and carbon dioxide (CO2) emissions using several one-hour portable accumulation chamber (PAC) measurements from lambs and again as ewes, while grazing ryegrass based pasture. Many animals with PAC measurements were also measured in RC while fed alfalfa pellets at 2.0 × maintenance metabolizable energy requirements (MEm). Heritability estimates from mixed models for CH4 and CO2 production (g/d) were 0.19 and 0.16, respectively, when measured using PAC with lambs; 0.20 and 0.27, respectively, when measured using PAC with ewes; and 0.23 and 0.34, respectively, when measured using RC with lambs. For measured gas traits, repeatabilities of measurements collected 14 days apart ranged from 0.33 to 0.55 for PAC (combined lambs and ewes) and were greater at 0.65 to 0.76 for the same traits measured using RC. Genetic correlations (rg) between PAC in lambs and ewes were 0.99 for CH4, 0.93 for CH4+CO2 and 0.85 for CH4/(CH4+CO2), suggesting CH4 emissions in lambs and ewes are the same trait. Genetic correlations between PAC and RC measurements were lower, at 0.62 to 0.67 for CH4 and 0.41 to 0.42 for CH4+CO2, likely reflecting different environmental conditions associated with the protocols used with the two measurement methods. The CH4/(CH4+CO2) ratio was the most similar genetic trait measured using PAC (both lambs and ewes, 63 and 66% selection efficiency, respectively) compared with CH4 yield (g/kg DMI) measured using RC. These results suggest that PAC measurements have considerable value as a rapid low cost method to estimate breeding values for CH4 emissions in sheep.

  5. Efficiency profile method to study the hit efficiency of drift chambers

    International Nuclear Information System (INIS)

    Abyzov, A.; Bel'kov, A.; Lanev, A.; Spiridonov, A.; Walter, M.; Hulsbergen, W.

    2002-01-01

    A method based on the usage of efficiency profile is proposed to estimate the hit efficiency of drift chambers with a large number of channels. The performance of the method under real conditions of the detector operation has been tested analysing the experimental data from the HERA-B drift chambers

  6. A new method for measuring the response time of the high pressure ionization chamber

    International Nuclear Information System (INIS)

    Wang, Zhentao; Shen, Yixiong; An, Jigang

    2012-01-01

    Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. - Highlights: ► A method for measuring response time of high pressure ionization chamber is proposed. ► A pulsed X-ray producer and a digital oscilloscope are used in the method. ► The response time of a 15 atm Xenon testing ionization chamber has been measured. ► The method has been proved to be simple, feasible and effective.

  7. Automatic semi-continuous accumulation chamber for diffuse gas emissions monitoring in volcanic and non-volcanic areas

    Science.gov (United States)

    Lelli, Matteo; Raco, Brunella; Norelli, Francesco; Virgili, Giorgio; Continanza, Davide

    2016-04-01

    Since various decades the accumulation chamber method is intensively used in monitoring activities of diffuse gas emissions in volcanic areas. Although some improvements have been performed in terms of sensitivity and reproducibility of the detectors, the equipment used for measurement of gas emissions temporal variation usually requires expensive and bulky equipment. The unit described in this work is a low cost, easy to install-and-manage instrument that will make possible the creation of low-cost monitoring networks. The Non-Dispersive Infrared detector used has a concentration range of 0-5% CO2, but the substitution with other detector (range 0-5000 ppm) is possible and very easy. Power supply unit has a 12V, 7Ah battery, which is recharged by a 35W solar panel (equipped with charge regulator). The control unit contains a custom programmed CPU and the remote transmission is assured by a GPRS modem. The chamber is activated by DataLogger unit, using a linear actuator between the closed position (sampling) and closed position (idle). A probe for the measure of soil temperature, soil electrical conductivity, soil volumetric water content, air pressure and air temperature is assembled on the device, which is already arranged for the connection of others external sensors, including an automatic weather station. The automatic station has been tested on the field at Lipari island (Sicily, Italy) during a period of three months, performing CO2 flux measurement (and also weather parameters), each 1 hour. The possibility to measure in semi-continuous mode, and at the same time, the gas fluxes from soil and many external parameters, helps the time series analysis aimed to the identification of gas flux anomalies due to variations in deep system (e.g. onset of volcanic crises) from those triggered by external conditions.

  8. Accumulation and dissipation of positive charges induced on a PMMA build-up cap of an ionisation chamber by 60Co gamma-ray irradiation

    International Nuclear Information System (INIS)

    Morishita, Y.; Takata, N.

    2013-01-01

    The signal current from an ionisation chamber with a PMMA build-up cap decreases with irradiation time due to electric fields produced by positive charges induced on the cap. In the present study, it was confirmed that the signal current decreases faster for irradiation using narrower 60 Co gamma-ray beams. This is because the number of secondary electrons that are emitted from surrounding materials and penetrate the build-up cap is smaller in a narrower gamma-ray beam, so that fewer positive charges are neutralised. The ionisation chamber was first subjected to continuous gamma-ray irradiation for 24 h, following which it was irradiated with shorter periodic gamma-ray bursts while measuring the current signal. This allowed the coefficients of positive charge accumulation and dissipation to be determined. It was found that the dissipation coefficient has a large constant value during gamma-ray irradiation and decreases asymptotically to a small value after irradiation is stopped. From the coefficients, the minimum signal current was calculated, which is the value when accumulation and dissipation balance each other under continuous irradiation. The time required for the signal current to recover following irradiation was also calculated. (authors)

  9. Continuous measurements of methane flux in two Japanese temperate forests based on the micrometeorological and chamber methods

    Science.gov (United States)

    Yoshikawa, K.; Ueyama, M.; Takagi, K.; Kominami, Y.

    2015-12-01

    Methane (CH4) budget in forest ecosystems have not been accurately quantified due to limited measurements and considerable spatiotemporal heterogeneity. In order to quantify CH4 fluxes at temperate forest at various spatiotemporal scales, we have continuously measured CH4 fluxes at two upland forests based on the micrometeorological hyperbolic relaxed eddy accumulation (HREA) and automated dynamic closed chamber methods.The measurements have been conducted at Teshio experimental forest (TSE) since September 2013 and Yamashiro forest meteorology research site (YMS) since November 2014. Three automated chambers were installed on each site. Our system can measure CH4 flux by the micrometeorological HREA, vertical concentration profile at four heights, and chamber measurements by a laser-based gas analyzer (FGGA-24r-EP, Los Gatos Research Inc., USA).Seasonal variations of canopy-scale CH4 fluxes were different in each site. CH4 was consumed during the summer, but was emitted during the fall and winter in TSE; consequently, the site acted as a net annual CH4 source. CH4 was steadily consumed during the winter, but CH4 fluxes fluctuated between absorption and emission during the spring and summer in YMS. YMS acted as a net annual CH4 sink. CH4 uptake at the canopy scale generally decreased with rising soil temperature and increased with drying condition for both sites. CH4 flux measured by most of chambers showed the consistent sensitivity examined for the canopy scale to the environmental variables. CH4 fluxes from a few chambers located at a wet condition were independent of variations in soil temperature and moisture at both sites. Magnitude of soil CH4 uptake was higher than the canopy-scale CH4 uptake. Our results showed that the canopy-scale CH4 fluxes were totally different with the plot-scale CH4 fluxes by chambers, suggesting the considerable spatial heterogeneity in CH4 flux at the temperate forests.

  10. Four-year measurement of methane flux over a temperate forest with a relaxed eddy accumulation method

    Science.gov (United States)

    Sakabe, A.; Kosugi, Y.; Ueyama, M.; Hamotani, K.; Takahashi, K.; Iwata, H.; Itoh, M.

    2013-12-01

    Forests are generally assumed to be an atmospheric methane (CH4) sink (Le Mer and Roger, 2001). However, under Asian monsoon climate, forests are subject to wide spatiotemporal range in soil water status, where forest soils often became water-saturated condition heterogeneously. In such warm and humid conditions, forests may act as a CH4 source and/or sink with considerable spatiotemporal variations. Micrometeorological methods such as eddy covariance (EC) method continuously measure spatially-representative flux at a canopy scale without artificial disturbance. In this study, we measured CH4 fluxes over a temperate forest during four-year period using a CH4 analyzer based on tunable diode laser spectroscopy detection with a relaxed eddy accumulation (REA) method (Hamotani et al., 1996, 2001). We revealed the amplitude and seasonal variations of canopy-scale CH4 fluxes. The REA method is the attractive alternative to the EC method to measure trace-gas flux because it allows the use of analyzers with an optimal integration time. We also conducted continuous chamber measurements on forest floor to reveal spatial variations in soil CH4 fluxes and its controlling processes. The observations were made in an evergreen coniferous forest in central Japan. The site has a warm temperate monsoon climate with wet summer. Some wetlands were located in riparian zones along streams within the flux footprint area. For the REA method, the sonic anemometer (SAT-550, Kaijo) was mounted on top of the 29-m-tall tower and air was sampled from just below the sonic anemometer to reservoirs according to the direction of vertical wind velocity (w). After accumulating air for 30 minutes, the air in the reservoirs was pulled into a CO2/H2O gas analyzer (LI-840, Li-Cor) and a CH4 analyzer (FMA-200, Los Gatos Research). Before entering the analyzers, the sampled air was dried using a gas dryer (PD-50 T-48; Perma Pure Inc.). The REA flux is obtained from the difference in the mean concentrations

  11. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    Energy Technology Data Exchange (ETDEWEB)

    Palmans, H [Ghent Univ. (Belgium). Dept. of Biomedical Physics; Verhaegen, F

    1995-12-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire`s multiple scattering theory and Vavilov`s energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program`s accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented.

  12. Evaluation of ion chamber dependent correction factors for ionisation chamber dosimetry in proton beams using a Monte Carlo method

    International Nuclear Information System (INIS)

    Palmans, H.; Verhaegen, F.

    1995-01-01

    In the last decade, several clinical proton beam therapy facilities have been developed. To satisfy the demand for uniformity in clinical (routine) proton beam dosimetry two dosimetry protocols (ECHED and AAPM) have been published. Both protocols neglect the influence of ion chamber dependent parameters on dose determination in proton beams because of the scatter properties of these beams, although the problem has not been studied thoroughly yet. A comparison between water calorimetry and ionisation chamber dosimetry showed a discrepancy of 2.6% between the former method and ionometry following the ECHED protocol. Possibly, a small part of this difference can be attributed to chamber dependent correction factors. Indications for this possibility are found in ionometry measurements. To allow the simulation of complex geometries with different media necessary for the study of those corrections, an existing proton Monte Carlo code (PTRAN, Berger) has been modified. The original code, that applies Mollire's multiple scattering theory and Vavilov's energy straggling theory, calculates depth dose profiles, energy distributions and radial distributions for pencil beams in water. Comparisons with measurements and calculations reported in the literature are done to test the program's accuracy. Preliminary results of the influence of chamber design and chamber materials on dose to water determination are presented

  13. In Vitro Culturing and Live Imaging of Drosophila Egg Chambers: A History and Adaptable Method.

    Science.gov (United States)

    Peters, Nathaniel C; Berg, Celeste A

    2016-01-01

    The development of the Drosophila egg chamber encompasses a myriad of diverse germline and somatic events, and as such, the egg chamber has become a widely used and influential developmental model. Advantages of this system include physical accessibility, genetic tractability, and amenability to microscopy and live culturing, the last of which is the focus of this chapter. To provide adequate context, we summarize the structure of the Drosophila ovary and egg chamber, the morphogenetic events of oogenesis, the history of egg-chamber live culturing, and many of the important discoveries that this culturing has afforded. Subsequently, we discuss various culturing methods that have facilitated analyses of different stages of egg-chamber development and different types of cells within the egg chamber, and we present an optimized protocol for live culturing Drosophila egg chambers.We designed this protocol for culturing late-stage Drosophila egg chambers and live imaging epithelial tube morphogenesis, but with appropriate modifications, it can be used to culture egg chambers of any stage. The protocol employs a liquid-permeable, weighted "blanket" to gently hold egg chambers against the coverslip in a glass-bottomed culture dish so the egg chambers can be imaged on an inverted microscope. This setup provides a more buffered, stable, culturing environment than previously published methods by using a larger volume of culture media, but the setup is also compatible with small volumes. This chapter should aid researchers in their efforts to culture and live-image Drosophila egg chambers, further augmenting the impressive power of this model system.

  14. Evaluation of functioning of an extrapolation chamber using Monte Carlo method

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Alfonso Laguardia, R.

    2015-01-01

    The extrapolation chamber is a parallel plate chamber and variable volume based on the Braff-Gray theory. It determines in absolute mode, with high accuracy the dose absorbed by the extrapolation of the ionization current measured for a null distance between the electrodes. This camera is used for dosimetry of external beta rays for radiation protection. This paper presents a simulation for evaluating the functioning of an extrapolation chamber type 23392 of PTW, using the MCNPX Monte Carlo method. In the simulation, the fluence in the air collector cavity of the chamber was obtained. The influence of the materials that compose the camera on its response against beta radiation beam was also analysed. A comparison of the contribution of primary and secondary radiation was performed. The energy deposition in the air collector cavity for different depths was calculated. The component with the higher energy deposition is the Polymethyl methacrylate block. The energy deposition in the air collector cavity for chamber depth 2500 μm is greater with a value of 9.708E-07 MeV. The fluence in the air collector cavity decreases with depth. It's value is 1.758E-04 1/cm 2 for chamber depth 500 μm. The values reported are for individual electron and photon histories. The graphics of simulated parameters are presented in the paper. (Author)

  15. Automated flux chamber for investigating gas flux at water-air interfaces.

    Science.gov (United States)

    Duc, Nguyen Thanh; Silverstein, Samuel; Lundmark, Lars; Reyier, Henrik; Crill, Patrick; Bastviken, David

    2013-01-15

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Representative measurements of GHG fluxes from aquatic ecosystems to the atmosphere are vital for quantitative understanding of relationships between biogeochemistry and climate. Fluxes occur at high temporal variability at diel or longer scales, which are not captured by traditional short-term deployments (often in the order of 30 min) of floating flux chambers. High temporal frequency measurements are necessary but also extremely labor intensive if manual flux chamber based methods are used. Therefore, we designed an inexpensive and easily mobile automated flux chamber (AFC) for extended deployments. The AFC was designed to measure in situ accumulation of gas in the chamber and also to collect gas samples in an array of sample bottles for subsequent analysis in the laboratory, providing two independent ways of CH(4) concentration measurements. We here present the AFC design and function together with data from initial laboratory tests and from a field deployment.

  16. Accumulation chamber as monitoring system for biogas emission from solid waste land filling: preliminary experimental results and elaborations on italian provincial scale

    International Nuclear Information System (INIS)

    Capaccioni, B.; Pirillo, L.; Didero, M.; Lucci, P.; Scartoni, P.; Tatano, F.

    2005-01-01

    On site CO 2 flux measurements with the static, not stationary accumulation chamber system were experimentally carried out in no. 5 MSW (active and closed) landfills located in the territory of the Province of Arezzo (Tuscany Region). Corresponding CO 2 emission flux maps were contoured and analysed, revealing a possible, preliminary geometrical classification of biogas dispersion: diffuse dispersion (internal), lateral/angular dispersion (internal), and external dispersion. Also specific (volume and surface) biogas emission parameters were calculated and graphically compared for the monitored inactive facilities [it

  17. Two methods to estimate the position resolution for straw chambers with strip readout

    International Nuclear Information System (INIS)

    Golutvin, I.A.; Movchan, S.A.; Peshekhonov, V.D.; Preda, T.

    1992-01-01

    The centroid and charge-ratio methods are presented to estimate the position resolution of the straw chambers with strip readout. For the straw chambers of 10 mm in diameter, the highest position resolution was obtained for a strip pitch of 5 mm. With the centroid method and perpendicular X-ray beam, the position resolution was ≅120 μm, for the signal-to-noise ratio of 60-65. The charge-ratio method has demonstrated ≅10% better position resolution at the edges of the strip. 6 refs.; 5 figs

  18. Lifetime and shelf life of sealed tritium-filled plasma focus chambers with gas generator

    Directory of Open Access Journals (Sweden)

    B.D. Lemeshko

    2017-11-01

    Full Text Available The paper describes the operation features of plasma focus chambers using deuterium–tritium mixture. Handling tritium requires the use of sealed, vacuum-tight plasma focus chambers. In these chambers, there is an accumulation of the impurity gases released from the inside surfaces of the electrodes and the insulator while moving plasma current sheath inside chambers interacting with β-electrons generated due to the decay of tritium. Decay of tritium is also accompanied by the accumulation of helium. Impurities lead to a decreased yield of neutron emission from plasma focus chambers, especially for long term operation. The paper presents an option of absorption type gas generator in the chamber based on porous titanium, which allows to significantly increase the lifetime and shelf life of tritium chambers. It also shows the results of experiments on the comparison of the operation of sealed plasma focus chambers with and without the gas generator. Keywords: Plasma focus, Neutron yield, Tritium-filled plasma focus chambers, PACS Codes: 29.25.-v, 52.58.Lq

  19. Ionization chambers

    International Nuclear Information System (INIS)

    Boag, J.W.

    1987-01-01

    Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed

  20. Method of correcting eddy current magnetic fields in particle accelerator vacuum chambers

    Science.gov (United States)

    Danby, Gordon T.; Jackson, John W.

    1991-01-01

    A method for correcting magnetic field aberrations produced by eddy currents induced in a particle accelerator vacuum chamber housing is provided wherein correction windings are attached to selected positions on the housing and the windings are energized by transformer action from secondary coils, which coils are inductively coupled to the poles of electro-magnets that are powered to confine the charged particle beam within a desired orbit as the charged particles are accelerated through the vacuum chamber by a particle-driving rf field. The power inductively coupled to the secondary coils varies as a function of variations in the power supplied by the particle-accelerating rf field to a beam of particles accelerated through the vacuum chamber, so the current in the energized correction coils is effective to cancel eddy current flux fields that would otherwise be induced in the vacuum chamber by power variations in the particle beam.

  1. Development and evaluation of an inhalation chamber for in vivo tests

    Directory of Open Access Journals (Sweden)

    EDUARDO R. DA SILVA

    2017-08-01

    Full Text Available ABSTRACT The bioavailability, toxicity, and therapeutic efficacy of a drug is directly related to its administration route. The pulmonary route can be accessed by inhalation after fumigation, vaporization or nebulization. Thus, pharmacological and toxicological evaluation accessed by an apparatus specifically designed and validated for this type of administration is extremely important. Based on pre-existing models, an inhalation chamber was developed. This presents a central structure with five animal holders. The nebulized air passes directly and continuously through these holders and subsequently to an outlet. Evaluation of its operation was performed using clove essential oil, a nebulizer, and a flow meter. The air within the chamber was collected by static headspace and analyzed by gas chromatography with a flame ionization detector. For this purpose, a 2.5 minutes chromatographic method was developed. The air flow in each of the five outputs was 0.92 liters per minute. During the first minute, the chamber became saturated with the nebulized material. Homogeneous and continuous operation of the chamber was observed without accumulation of volatile material inside it for 25 minutes. The inhalation chamber works satisfactorily for in vivo tests with medicines designed to be administrated by inhalation.

  2. Electrodynamic modeling applied to micro-strip gas chambers

    International Nuclear Information System (INIS)

    Fang, R.

    1998-01-01

    Gas gain variations as functions of time, counting rate and substrate resistivity have been observed with Micro-Strip Gas Chambers (MSGC). Such a chamber is here treated as a system of 2 dielectrics, gas and substrate, with finite resistivities. Electric charging between their interface results in variations of the electric field and the gas gain. The electrodynamic equations (including time dependence) for such a system are proposed. A Rule of Charge Accumulation (RCA) is then derived which allows to determine the quantity and sign of charges accumulated on the surface at equilibrium. In order to apply the equations and the rule to MSGCs, a model of gas conductance induced by ionizing radiation is proposed, and a differential equation and some formulae are derived to calculate the rms dispersion and the spatial distribution of electrons (ions) in inhomogeneous electric fields. RCA coupled with a precise simulation of the electric fields gives the first quantitative explanation of gas gain variations of MSGCs. Finally an electrodynamic simulation program is made to reproduce the dynamic process of gain variation due to surface charging with an uncertainty of at most 15% relative to experimental data. As a consequence, the methods for stabilizing operation of MSGCs are proposed. (author)

  3. A cool-temperate young larch plantation as a net methane source - A 4-year continuous hyperbolic relaxed eddy accumulation and chamber measurements

    Science.gov (United States)

    Ueyama, Masahito; Yoshikawa, Kota; Takagi, Kentaro

    2018-07-01

    Upland forests are thought to be methane (CH4) sinks due to oxidation by methanotrophs in aerobic soils. However, CH4 budget for upland forests are not well quantified at the ecosystem scale, when possible CH4 sources, such as small wet areas, exists in the ecosystem. Here, we quantified CH4 fluxes in a cool-temperate larch plantation based on four-year continuous measurements using the hyperbolic relaxed eddy accumulation (HREA) method and dynamic closed chambers with a laser-based analyzer. After filling data gaps for half-hourly data using machine-learning-based regressions, we found that the forest acted as a net CH4 source at the canopy scale: 30 ± 11 mg CH4 m-2 yr-1 in 2014, 56 ± 8 mg CH4 m-2 yr-1 in 2015, 154 ± 5 mg CH4 m-2 yr-1 in 2016, and 132 ± 6 mg CH4 m-2 yr-1 in 2017. Hotspot emissions from the edge of the pond could strongly contribute to the canopy-scale emissions. The magnitude of the hotspot emissions was 10-100 times greater than the order of the canopy-scale and chamber-based CH4 fluxes at the dry soils. The high temperatures with wet conditions stimulated the hotspot emissions, and thus induced canopy-scale CH4 emissions in the summer. Understanding and modeling the dynamics of hotspot emissions are important for quantifying CH4 budgets of upland forests. Micrometeorological measurements at various forests are required for revisiting CH4 budget of upland forests.

  4. Peltier-based cloud chamber

    Science.gov (United States)

    Nar, Sevda Yeliz; Cakir, Altan

    2018-02-01

    Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.

  5. New method to analyze super-family events observed with emulsion chambers

    International Nuclear Information System (INIS)

    Amenomori, M.

    1997-01-01

    The authors have developed a clustering method to analyze family events observed with emulsion chambers at high mountains. The main purpose of this analysis is to estimate the main production height of individual events, angular spread of gamma-rays in each event and so on. These enable them to investigate hadronic interactions at energies over 10 16 eV inaccessible by the present high-energy accelerators. they examined their clustering method using Monte Carlo events, and found that for the family events whose production height is low (within 2-3 km above the observation point in air), their production heights and lateral spreads are well reproduced. They further applied their method to the super-family events (ΣE γ > 1000 TeV) observed with emulsion chambers at Mt. Kanbala (5500 m above sea-level). The results seem to suggest that particle production with large transverse momentum occurs with considerable frequency even in the fragmentation region in the energy region over 10 16 eV

  6. Comparing calibration methods of electron beams using plane-parallel chambers with absorbed-dose to water based protocols

    International Nuclear Information System (INIS)

    Stewart, K.J.; Seuntjens, J.P.

    2002-01-01

    Recent absorbed-dose-based protocols allow for two methods of calibrating electron beams using plane-parallel chambers, one using the N D,w Co for a plane-parallel chamber, and the other relying on cross-calibration of the plane-parallel chamber in a high-energy electron beam against a cylindrical chamber which has an N D,w Co factor. The second method is recommended as it avoids problems associated with the P wall correction factors at 60 Co for plane-parallel chambers which are used in the determination of the beam quality conversion factors. In this article we investigate the consistency of these two methods for the PTW Roos, Scanditronics NACP02, and PTW Markus chambers. We processed our data using both the AAPM TG-51 and the IAEA TRS-398 protocols. Wall correction factors in 60 Co beams and absorbed-dose beam quality conversion factors for 20 MeV electrons were derived for these chambers by cross-calibration against a cylindrical ionization chamber. Systematic differences of up to 1.6% were found between our values of P wall and those from the Monte Carlo calculations underlying AAPM TG-51, and up to 0.6% when comparing with the IAEA TRS-398 protocol. The differences in P wall translate directly into differences in the beam quality conversion factors in the respective protocols. The relatively large spread in the experimental data of P wall , and consequently the absorbed-dose beam quality conversion factor, confirms the importance of the cross-calibration technique when using plane-parallel chambers for calibrating clinical electron beams. We confirmed that for well-guarded plane-parallel chambers, the fluence perturbation correction factor at d max is not significantly different from the value at d ref . For the PTW Markus chamber the variation in the latter factor is consistent with published fits relating it to average energy at depth

  7. Drift chamber

    International Nuclear Information System (INIS)

    Inagaki, Yosuke

    1977-01-01

    Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)

  8. Assessment of condensation of water vapor in the mixing chamber by CFD method

    Directory of Open Access Journals (Sweden)

    Vojkůvková Petra

    2015-01-01

    Full Text Available The analyzed topic belongs to the field of design and operation of HVAC systems, focusing mainly on mixing chambers. The paper deals with problems of condensation and freezing of water vapour on walls of mixing chambers in a special case, when the partial pressure of the final resulting state of the mixture of warm moist air and colder air is located above the saturation limit. Experimental in situ methods and computer computational fluid dynamics (CFD modelling method were used for processing. The main contribution of this work is the finding that partial condensation and freezing of water vapour may occur in local parts of the mixing chamber. It causes problems in terms of hygienic safety and service life of these devices. In particular it has been found that condensation and freezing of water vapour may occur even if relative humidity of the resulting mixture is about 70 %.

  9. The methodics of the identification of π-p elastic interactions in bubble chamber

    International Nuclear Information System (INIS)

    Balea, E.; Berceanu, S.; Coca, C.; Sararu, A.; Mihul, A.L.M.; Balea, O.; Karnauhov, V.M.; Moroz, V.I.

    1979-01-01

    A method for elastic events separation from the two prong-events in a hydrogen bubble chamber exposed to π - meson-beams is presented. It is argued that for elastic events the simultaneous cuts in the angle of coplanarity and the angular kinematical correlation are less sensitive to the experimental errors than in other kinematical correlations. The proposed methodics is compared with other current technics for elastic events identification. Our method for elastic events separation has been tested on a sample of two prong-events from the CERN 2m H 2 bubble chamber exposed to a beam of 16 GeV/c π - mesons. The processing of elastic events candidates is presented too. (author)

  10. Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams

    International Nuclear Information System (INIS)

    Andersson, Jonas; Toelli, Heikki

    2011-01-01

    A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a liquid ionization chamber and an air filled monitor ionization chamber at two different dose rates. The method has been tested with two plane parallel liquid ionization chambers in a continuous radiation x-ray beam with a tube voltage of 120 kV and with dose rates between 2 and 13 Gy min -1 . The liquids used as sensitive media in the chambers were isooctane (C 8 H 18 ) and tetramethylsilane (Si(CH 3 ) 4 ). The general recombination effect was studied using chamber polarizing voltages of 100, 300, 500, 700 and 900 V for both liquids. The relative standard deviation of the results for the collection efficiency with respect to general recombination was found to be a maximum of 0.7% for isooctane and 2.4% for tetramethylsilane. The results are in excellent agreement with Greening's theory for collection efficiencies over 90%. The measured and corrected signals from the liquid ionization chambers used in this work are in very good agreement with the air filled monitor chamber with respect to signal to dose linearity.

  11. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.

    1988-01-01

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of γ-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF 3 ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs

  12. Annual Net Ecosystem Productivity of Wetlands: A Comparison of Automated and Manual Chamber Methods

    Science.gov (United States)

    Burrows, E. H.; Bubier, J. L.; Mosedale, A.; Crill, P. M.

    2001-05-01

    Net Ecosystem Exchange (NEE) of carbon dioxide (CO2) was measured in a minerotrophic poor fen in southeastern New Hampshire during the 2000 growing season using two types of chamber methods. Instantaneous CO2 flux was measured with transparent lexan and teflon static climate controlled chambers by calculating the change in headspace CO2 concentration in the chamber over time. Once per week the flux was sampled from ten manually operated chambers using a LI-COR 6200 portable photosynthesis system, which included a LI-6250 infrared gas analyzer, connected to the chambers. Ten automated chambers were installed in May of 2000, sampling CO2 flux every three hours over the diurnal cycle using a LI-COR 6262 infrared gas analyzer. The chambers and collars were placed throughout the fen in order to sample the range of plant communities. The manual sampling was done during the middle of the day, but the rate of photosynthesis changes depending on the amount of photosynthetically active radiation (PAR). In order to simulate varying light levels, shrouds blocking different amounts of light were placed over each manual chamber. An opaque shroud was used to measure respiration. NEE ranged from -13.0 to 12.5 μ mol CO2/m2/s in the manual chambers and -16.2 to 11.8 μ mol CO2/m2/s in the automated chambers for the mid-summer growing season. Manual respiration fluxes were measured under higher temperature regimes and the response of respiration to temperature will be factored in when comparing the two chamber techniques. Research during the summer of 2001 will also include diurnal measurements. Growing season net ecosystem productivity (NEP) will be estimated and compared for the two chamber systems. Several models will be used to estimate the flux when the manual chambers were not being sampled. The models will be based on biomass and dominant species in each chamber, and various environmental factors including water table, pH, relative humidity, PAR, air and peat temperature

  13. Radiation damage to tetramethylsilane and tetramethylgermanium ionization chambers

    International Nuclear Information System (INIS)

    Hoshi, Y.; Higuchi, M.; Oyama, K.

    1994-01-01

    Two detector media suitable for a warm liquid, ionization chamber filled with tetramethylsilane (TMS) and tetramethylgermanium (TMG) were exposed to γ radiation form a 60 Co source up to dose 579 Gray and 902 Gray, respectively. The electron lifetimes and the free ion yields were measured as a function of accumulated radiation dose. A similar behavior of the electron lifetimes and the free ion yields with increasing radiation does was observed between the TMS and TMG ionization chambers

  14. Method agreement between measuring of boar sperm concentration using Makler chamber and photometer

    OpenAIRE

    Mrkun Janko; Kosec M.; Zakošek Maja; Zrimšek Petra

    2007-01-01

    Determination of boar sperm concentration using a photometer is used routinely by many artificial insemination (AI) laboratories. The agreement between determining sperm concentration using Makler chamber and a photometer has been assessed. Method agreement was evaluated on the basis of scatter plots with Deming regression line, absolute bias plots with limits of agreement, and relative bias plots. Coefficients of variance for the Makler chamber and a photometer were calculated as 6.575+3.461...

  15. Relativistic rise measurement by cluster counting method in time expansion chamber

    International Nuclear Information System (INIS)

    Rehak, P.; Walenta, A.H.

    1979-10-01

    A new approach to the measurement of the ionization energy loss for the charged particle identification in the region of the relativistic rise was tested experimentally. The method consists of determining in a special drift chamber (TEC) the number of clusters of the primary ionization. The method gives almost the full relativistic rise and narrower landau distribution. The consequences for a practical detector are discussed

  16. Effect of chamber enclosure time on soil respiration flux: A comparison of linear and non-linear flux calculation methods

    DEFF Research Database (Denmark)

    Kandel, Tanka P; Lærke, Poul Erik; Elsgaard, Lars

    2016-01-01

    One of the shortcomings of closed chamber methods for soil respiration (SR) measurements is the decreased CO2 diffusion rate from soil to chamber headspace that may occur due to increased chamber CO2 concentrations. This feedback on diffusion rate may lead to underestimation of pre-deployment flu......One of the shortcomings of closed chamber methods for soil respiration (SR) measurements is the decreased CO2 diffusion rate from soil to chamber headspace that may occur due to increased chamber CO2 concentrations. This feedback on diffusion rate may lead to underestimation of pre...... was placed on fixed collars, and CO2 concentration in the chamber headspace were recorded at 1-s intervals for 45 min. Fluxes were measured in different soil types (sandy, sandy loam and organic soils), and for various manipulations (tillage, rain and drought) and soil conditions (temperature and moisture......) to obtain a range of fluxes with different shapes of flux curves. The linear method provided more stable flux results during short enclosure times (few min) but underestimated initial fluxes by 15–300% after 45 min deployment time. Non-linear models reduced the underestimation as average underestimation...

  17. Method for automatic determination of soybean actual evapotranspiration under open top chambers (OTC) subjected to effects of water stress and air ozone concentration.

    Science.gov (United States)

    Rana, Gianfranco; Katerji, Nader; Mastrorilli, Marcello

    2012-10-01

    The present study describes an operational method, based on the Katerji et al. (Eur J Agron 33:218-230, 2010) model, for determining the daily evapotranspiration (ET) for soybean inside open top chambers (OTCs). It includes two functions, calculated day par day, making it possible to separately take into account the effects of concentrations of air ozone and plant water stress. This last function was calibrated in function of the daily values of actual water reserve in the soil. The input variables of the method are (a) the diurnal values of global radiation and temperature, usually measured routinely in a standard weather station; (b) the daily values of the AOT40 index accumulated (accumulated ozone over a threshold of 40 ppb during daylight hours, when global radiation exceeds 50 Wm(-2)) determined inside the OTC; and (c) the actual water reserve in the soil, at the beginning of the trial. The ensemble of these input variables can be automatable; thus, the proposed method could be applied in routine. The ability of the method to take into account contrasting conditions of ozone air concentration and water stress was evaluated over three successive years, for 513 days, in ten crop growth cycles, excluding the days employed to calibrate the method. Tests were carried out in several chambers for each year and take into account the intra- and inter-year variability of ET measured inside the OTCs. On the daily scale, the slope of the linear regression between the ET measured by the soil water balance and that calculated by the proposed method, under different water conditions, are 0.98 and 1.05 for the filtered and unfiltered (or enriched) OTCs with root mean square error (RMSE) equal to 0.77 and 1.07 mm, respectively. On the seasonal scale, the mean difference between measured and calculated ET is equal to +5% and +11% for the filtered and unfiltered OTCs, respectively. The ability of the proposed method to estimate the daily and seasonal ET inside the OTCs is

  18. The method of activity determination of Tc-99m in ionization chamber

    International Nuclear Information System (INIS)

    Broda, R.

    1980-01-01

    The paper presents a method of finding the efficiency of sup(99m)Tc activity measurements in the ionization chamber, basing on 99 Mo activity measurements and the activity ratio of sup(99m)Tc to 99 Mo in 99 Mo + sup(99m)Tc solution. The activity of 99 Mo has been determined in 4πβ-γ coincidence system with liquid scintillator in β channel by means of the absolute method of two-stage coincidence. The activity ratio of sup(99m)Tc to 99 Mo has been determined by means of spectrometric method. The 99 Mo and sup(99m)Tc activities have been measured in 99 Mo + sup(99m)Tc generators, and the activity of sup(99m)Tc solution after elution has been measured. It has been shown that sup(99m)Tc activity, determined by means of the chamber method on the basis of the efficiency found, corresponds to the activity determined by means of spectrometric method, and that sup(99m)Tc activity, measured in generator before elution, is equal to the sum of sup(99m)Tc activity eluted and the one remained in generator. (author)

  19. Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Kovler, Konstantin; Miklyaev, Peter

    2016-01-01

    Radon exhalation rate from the soil surface can serve as an important criterion in the evaluation of radon hazard of the land. Recently published international standard ISO 11665-7 (2012) is based on the accumulation of radon gas in a closed container. At the same time since 1998 in Russia, as a part of engineering and environmental studies for the construction, radon flux measurements are made using an open charcoal chamber for a sampling duration of 3–5 h. This method has a well-defined metrological justification and was tested in both favorable and unfavorable conditions. The article describes the characteristics of the method, as well as the means of sampling and measurement of the activity of radon absorbed. The results of the metrological study suggest that regardless of the sampling conditions (weather, the mechanism and rate of radon transport in the soil, soil properties and conditions), uncertainty of method does not exceed 20%, while the combined standard uncertainty of radon exhalation rate measured from the soil surface does not exceed 30%. The results of the daily measurements of radon exhalation rate from the soil surface at the experimental site during one year are reported. - Highlights: • Radon exhalation rate from the soil surface area of 32 cm"2 can be measured at level of 10 mBq/(m"2s) at the uncertainty ≤30%. • The method has a metrological justification. • No need to consider climate conditions, soil properties and conditions, mechanism and rate of radon transport in the soil.

  20. Method of repairing incore structure and water sealing chamber

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Toshikazu; Sato, Sukenobu (Hitachi Nuclear Engineering Co. Ltd., Ibaraki (Japan)); Wada, Noriaki; Kurosawa, Koichi; Tsujimura, Hiroshi; Enomoto, Kunio.

    1993-11-26

    An incore-chamber main body comprises a guide tube, an insertion guide, an extensible arm, a device fixing mechanism, a gas supply pipe, a guide driving mechanism and an in-core chamber control device. The in-core chamber main body is installed and secured to an upper flange surface of a shroud. Reactor water is raised to a level below a flange of a reactor pressure vessel while supplying a dry gas from a gas supply pipe to make the inside of the shroud as a gas atmosphere. Subsequently, each of the devices is attached to the top end of the extensible arm, and the guide driving mechanism is operated by the in-core chamber control device to an aimed position for preventive maintenance or repair to conduct positioning and fixing by utilizing the guide tube and the insertion guide. This enables to conduct preventive maintenance or repair in a state where reactor water is present to the outside of the in-core reactor chamber while maintaining the in-core equipment in the gas atmosphere, thereby enabling to reduce operator's exposure dose. (I.N.).

  1. Method of repairing incore structure and water sealing chamber

    International Nuclear Information System (INIS)

    Kikuchi, Toshikazu; Sato, Sukenobu; Wada, Noriaki; Kurosawa, Koichi; Tsujimura, Hiroshi; Enomoto, Kunio.

    1993-01-01

    An incore-chamber main body comprises a guide tube, an insertion guide, an extensible arm, a device fixing mechanism, a gas supply pipe, a guide driving mechanism and an in-core chamber control device. The in-core chamber main body is installed and secured to an upper flange surface of a shroud. Reactor water is raised to a level below a flange of a reactor pressure vessel while supplying a dry gas from a gas supply pipe to make the inside of the shroud as a gas atmosphere. Subsequently, each of the devices is attached to the top end of the extensible arm, and the guide driving mechanism is operated by the in-core chamber control device to an aimed position for preventive maintenance or repair to conduct positioning and fixing by utilizing the guide tube and the insertion guide. This enables to conduct preventive maintenance or repair in a state where reactor water is present to the outside of the in-core reactor chamber while maintaining the in-core equipment in the gas atmosphere, thereby enabling to reduce operator's exposure dose. (I.N.)

  2. Plastic flashtube chambers

    International Nuclear Information System (INIS)

    Frisken, W.R.

    1977-01-01

    A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber

  3. Using the method of statistic tests for determining the pressure in the UNC-600 vacuum chamber

    International Nuclear Information System (INIS)

    Kiver, A.M.; Mirzoev, K.G.

    1998-01-01

    The aim of the paper is to simulate the process of pumping-out the UNC-600 vacuum chamber. The simulation is carried out by the Monte-Carlo statistic test method. It is shown that the pressure value in every liner of the chamber may be determined from the pressure in the pump branch pipe, determined by the discharge current of this pump. Therefore, it is possible to precise the working pressure in the ion guide of the UNC-600 vacuum chamber [ru

  4. A straw chambers' tracker for the high rate experiment 835 at the Fermilab accumulator

    Science.gov (United States)

    Bagnasco, S.; Dughera, G.; Giraudo, G.; Govi, G.; Marchetto, F.; Menichetti, E.; Pastrone, N.; Rumerio, P.; Trapani, P. P.

    1998-02-01

    Two layers of proportional drift tubes (aluminum mylar straws) are staggered in two cylindrical light chambers to measure charged particles' azimuthal angle. To stand the high rates (˜10 kHz/ cm2) and minimize the pile-up of the high luminosity experiment 835 at FNAL, a fast ASIC Amplifier-Shaper-Discriminator (ASD-8B) was chosen. The front-end electronics, designed exclusively with SMD components, was mounted on the downstream end plug of each chamber to avoid oscillations and noise. Design, construction and operational performances of these detectors are presented.

  5. Algorithm for study on the stressed-strained state of thermonuclear device vacuum chambers under dynamic loads

    International Nuclear Information System (INIS)

    Zhuravleva, A.M.; Litvinov, V.B.

    1982-01-01

    The problem of dynamic analysis of stressed-strained state of vacuum chambers is vital for large thermonuclear devices during the stall of the plasma-filament apd other tpansitional operation regimes when loading for a chamber are nonstationary. To plot a mathematical model the design of the vacuum chamber is discreted on the basis of the method of final elements. To approximate vacuum shell, a plate triangular element with 3 joint points and 5 parameters in the joint is used. It is obtained due to the unity of the bemded element and the element for the flat problem. To investigate nonstationary oscillations of vacuum chambers discreted on the basis of the method of final elements, it is suggested to use the numeric conversion of the Japlace transformation. On the basis of the algorithm suggested a program of numerical function conversion is developed. Test calculations have shown a good stability of the algorithm when selecting the values of transformation parameter in the range of lower intrinsic system frequencies. The advantage of the above method is in the fact that the time-structure shift function is found instantly in the form of the series for the whole time interval and does not require temporary steps, which bring about large expenses of counting time and error accumulation

  6. Distribution of multi-component solvents in solvent vapor extraction chamber

    Energy Technology Data Exchange (ETDEWEB)

    Das, S. [Society of Petroleum Engineers, Richardson, TX (United States)]|[Marathon Oil Corp., Houston, TX (United States)

    2008-10-15

    Vapex process performance is sensitive to operating pressures, temperatures and the types of solvent used. The hydrocarbon solvents used in Vapex processes typically have between 5 and 10 per cent hydrocarbon impurities, and the accumulation of dense phases inside the vapor chamber reduces gravity drainage potential. This study investigated the partitioning of solvent compounds inside the vapor chamber during in situ Vapex processes.The aim of the study was to examine how the different components of the mixed solvent partitioned inside the extracted chamber during the oil and vapor phase. A 2-D homogenous reservoir model was used to simulate the Vapex process with a solvent mixture comprised of propane and methane at various percentages. The effect of injecting a hot solvent vapor was also investigated. The study showed that injected methane accumulated at both the top and the extraction interface. Accumulations near the top had a positive impact on solvent confinement in thin reservoirs. Diffusion of the solvent component was controlled by gas phase molecular diffusion, and was much faster than the diffusion of solvent molecules in the liquid phase. The use of hot solvent mixtures slowed the extraction process due to lower solvent solubility in the oil phase. It was concluded that the negative impact on viscosity reduction by dilution was not compensated by rises in temperature. 6 refs., 11 figs.

  7. Ducted combustion chamber for direct injection engines and method

    Science.gov (United States)

    Mueller, Charles

    2015-03-03

    An internal combustion engine includes an engine block having a cylinder bore and a cylinder head having a flame deck surface disposed at one end of the cylinder bore. A piston connected to a rotatable crankshaft and configured to reciprocate within the cylinder bore has a piston crown portion facing the flame deck surface such that a combustion chamber is defined within the cylinder bore and between the piston crown and the flame deck surface. A fuel injector having a nozzle tip disposed in fluid communication with the combustion chamber has at least one nozzle opening configured to inject a fuel jet into the combustion chamber along a fuel jet centerline. At least one duct defined in the combustion chamber between the piston crown and the flame deck surface has a generally rectangular cross section and extends in a radial direction relative to the cylinder bore substantially along the fuel jet centerline.

  8. Study of straw chamber lifetime with argon ethane

    International Nuclear Information System (INIS)

    Adler, J.; Bolton, T.; Bunnell, K.; Cheu, E.; Grab, C.; Mazaheri, G.; Odian, A.; Pitman, D.; Stockhausen, W.; Toki, W.; Wadley, W.; Wood, C.; Mir, R.

    1989-01-01

    We present detailed laboratory measurements of the lifetime of a small test chamber, simulating the Mark III straw vertex chamber conditions. The tests were carried out with an argon-ethane 50/50 gas mixture at 3 atm absolute pressure and 3.9 kV applied to the wires. After the accumulation of ≅ 0.02 C/cm on a single straw, continuous discharges began. The addition of alcohol or water vapor to the gas mixture was found to extend the lifetime of the straws. Continuous flow of the gas mixture with water vapor through the straws prolonged the lifetime significantly. We present results on the effects of changing the gas mixture inside the straws at regular time intervals. Adding a small percentage of water vapor to the argon-ethane gas and flowing the gas mixture in the straws can improve the lifetime by more than an order of magnitude. An accumulated charge of 1.0 C/cm on a single straw has been obtained. (orig.)

  9. A Model Parameter Extraction Method for Dielectric Barrier Discharge Ozone Chamber using Differential Evolution

    Science.gov (United States)

    Amjad, M.; Salam, Z.; Ishaque, K.

    2014-04-01

    In order to design an efficient resonant power supply for ozone gas generator, it is necessary to accurately determine the parameters of the ozone chamber. In the conventional method, the information from Lissajous plot is used to estimate the values of these parameters. However, the experimental setup for this purpose can only predict the parameters at one operating frequency and there is no guarantee that it results in the highest ozone gas yield. This paper proposes a new approach to determine the parameters using a search and optimization technique known as Differential Evolution (DE). The desired objective function of DE is set at the resonance condition and the chamber parameter values can be searched regardless of experimental constraints. The chamber parameters obtained from the DE technique are validated by experiment.

  10. Evaluation of ICT filariasis card test using whole capillary blood: comparison with Knott's concentration and counting chamber methods.

    Science.gov (United States)

    Njenga, S M; Wamae, C N

    2001-10-01

    An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.

  11. Injection and accumulation method in the TARN

    International Nuclear Information System (INIS)

    Yamada, S.; Katayama, T.

    1979-03-01

    The test accumulation ring for NUMATRON (TARN) is being constructed at INS, University of Tokyo. The main purpose of the TARN is to establish some techniques related to beam injection and RF stacking, ultrahigh vacuum, and beam monitoring and handling. In this paper, the injection and accumulation methods in the TARN are described. The combination of multiturn injection and RF stacking is applied to the TARN. Heavy ions from the INS sector focusing (SF) cyclotron are injection through a magnetic and an electrostatic inflectors. Two pulse magnets and a bump field excited by square wave current are used for the multiturn injection method. The procedure of the RF stacking is as follows. The beam from the cyclotron is transported to the ring, and is injected by a multiturn method. Then, the RF accelerating voltage is put on, and the beam is captured in the stable region of the RF acceleration. The RF voltage and the frequency are adiabatically changed, and the beam is moved to the stacking orbit. The RF voltage is put off, and the beam remains on the stacking orbit. In the present system, a repetitive stacking scheme is applied for the RF stacking. The momentum spread after the RF stacking is approximately proportional to the stacking number in synchrotron phase space. The stacking number is chosen so that the total aperture required for the combined method may not exceed the available aperture in the ring doughnut. (Kato, T.)

  12. Novel Direction Of Arrival Estimation Method Based on Coherent Accumulation Matrix Reconstruction

    Directory of Open Access Journals (Sweden)

    Li Lei

    2015-04-01

    Full Text Available Based on coherent accumulation matrix reconstruction, a novel Direction Of Arrival (DOA estimation decorrelation method of coherent signals is proposed using a small sample. First, the Signal to Noise Ratio (SNR is improved by performing coherent accumulation operation on an array of observed data. Then, according to the structure characteristics of the accumulated snapshot vector, the equivalent covariance matrix, whose rank is the same as the number of array elements, is constructed. The rank of this matrix is proved to be determined just by the number of incident signals, which realize the decorrelation of coherent signals. Compared with spatial smoothing method, the proposed method performs better by effectively avoiding aperture loss with high-resolution characteristics and low computational complexity. Simulation results demonstrate the efficiency of the proposed method.

  13. A basic radiation-education method using a handy-type cloud chamber and natural radiation sources

    International Nuclear Information System (INIS)

    Kushita, K. N.

    2010-10-01

    Nuclear human resources development becomes increasingly important due to the world trend of expanding nuclear energy utilization in this century. At the Nuclear Human Resource Development Center of the Japan Atomic Energy Agency, many kinds of nuclear and radiation education have been conducted consistently and continuously through its half-century history though having several organizational changes. High level education is required for the specialists of nuclear technology including nuclear power plants operators and engineers, while basic knowledge on nuclear energy and, specially, on radiations and radioisotopes should be given to school students and public. Besides lectures on radiation and radioisotopes, some basic experiments are useful to understand what are radiations and radioisotopes. One of such basic experiments is the cloud chamber experiment. It is a great fun and excitement even for small children as one can actually see the radiation tracks by his/her naked eyes at hand. While there are many types of cloud chambers, we have developed a new-type cloud chamber to use for the radiation education and training s. Using the new-type cloud chamber, we have further developed a new method of this experiment so that the participants can more deeply understand the phenomena and the nature of radiation and radioisotopes. In this method, using a radiation source of natural uranium ore and gaseous radiation source containing Rn-220 obtained from thorium-containing material, they not only observe the radiation tracks but also measure the length and count the number of the tracks. Then they can calculate the energy of the radiation (alpha ray) and can estimate the half-life of the radioisotope (Rn-220). This method can be applied for high-school and general university students as well as for the public as a useful and effective method in the radiation education. (Author)

  14. A basic radiation-education method using a handy-type cloud chamber and natural radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Kushita, K. N., E-mail: Kushita.kouhei@iaea.go.j [Japan Atomic Energy Agency, Nuclear Human Resource Development Center, 2-4 Shirakata-Shirane, Tokai, Naka, Ibaraki 309-1195 (Japan)

    2010-10-15

    Nuclear human resources development becomes increasingly important due to the world trend of expanding nuclear energy utilization in this century. At the Nuclear Human Resource Development Center of the Japan Atomic Energy Agency, many kinds of nuclear and radiation education have been conducted consistently and continuously through its half-century history though having several organizational changes. High level education is required for the specialists of nuclear technology including nuclear power plants operators and engineers, while basic knowledge on nuclear energy and, specially, on radiations and radioisotopes should be given to school students and public. Besides lectures on radiation and radioisotopes, some basic experiments are useful to understand what are radiations and radioisotopes. One of such basic experiments is the cloud chamber experiment. It is a great fun and excitement even for small children as one can actually see the radiation tracks by his/her naked eyes at hand. While there are many types of cloud chambers, we have developed a new-type cloud chamber to use for the radiation education and training s. Using the new-type cloud chamber, we have further developed a new method of this experiment so that the participants can more deeply understand the phenomena and the nature of radiation and radioisotopes. In this method, using a radiation source of natural uranium ore and gaseous radiation source containing Rn-220 obtained from thorium-containing material, they not only observe the radiation tracks but also measure the length and count the number of the tracks. Then they can calculate the energy of the radiation (alpha ray) and can estimate the half-life of the radioisotope (Rn-220). This method can be applied for high-school and general university students as well as for the public as a useful and effective method in the radiation education. (Author)

  15. Multi-element accumulation near Rumex crispus roots under wetland and dryland conditions

    International Nuclear Information System (INIS)

    Kissoon, La Toya T.; Jacob, Donna L.; Otte, Marinus L.

    2010-01-01

    Rumex crispus was grown under wet and dry conditions in two-chamber columns such that the roots were confined to one chamber by a 21 μm nylon mesh, thus creating a soil-root interface ('rhizoplane'). Element concentrations at 3 mm intervals below the 'rhizoplane' were measured. The hypothesis was that metals accumulate near plant roots more under wetland than dryland conditions. Patterns in element distribution were different between the treatments. Under dryland conditions Al, Ba, Cu, Cr, Fe, K, La, Mg, Na, Sr, V, Y and Zn accumulated in soil closest to the roots, above the 'rhizoplane' only. Under wetland conditions Al, Fe, Cr, K, V and Zn accumulated above as well as 3 mm below the 'rhizoplane' whereas La, Sr and Y accumulated 3 mm below the 'rhizoplane' only. Plants on average produced 1.5 times more biomass and element uptake was 2.5 times greater under wetland compared to dryland conditions. - Patterns of element accumulation near the roots of plants differ between dryland and wetland conditions.

  16. Phosphate recovery as struvite within a single chamber microbial electrolysis cell.

    Science.gov (United States)

    Cusick, Roland D; Logan, Bruce E

    2012-03-01

    An energy efficient method of concurrent hydrogen gas and struvite (MgNH(4)PO(4)·6H(2)O) production was investigated based on bioelectrochemically driven struvite crystallization at the cathode of a single chamber microbial electrolysis struvite-precipitation cell (MESC). The MESC cathodes were either stainless steel 304 mesh or flat plates. Phosphate removal ranged from 20% to 40%, with higher removals obtained using mesh cathodes than with flat plates. Cathode accumulated crystals were verified as struvite using a scanning electron microscope capable of energy dispersive spectroscopy (SEM-EDS). Crystal accumulation did not affect the rate of hydrogen production in struvite reactors. The rate of struvite crystallization (g/m(2)-h) and hydrogen production (m(3)/m(3)-d) were shown to be dependent on applied voltage and cathode material. Overall energy efficiencies (substrate and electricity) were high (73 ± 4%) and not dependent on applied voltage. These results show that MESCs may be useful both as a method for hydrogen gas and struvite production. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Phosphate recovery as struvite within a single chamber microbial electrolysis cell

    KAUST Repository

    Cusick, Roland D.

    2012-03-01

    An energy efficient method of concurrent hydrogen gas and struvite (MgNH 4PO 4·6H 2O) production was investigated based on bioelectrochemically driven struvite crystallization at the cathode of a single chamber microbial electrolysis struvite-precipitation cell (MESC). The MESC cathodes were either stainless steel 304 mesh or flat plates. Phosphate removal ranged from 20% to 40%, with higher removals obtained using mesh cathodes than with flat plates. Cathode accumulated crystals were verified as struvite using a scanning electron microscope capable of energy dispersive spectroscopy (SEM-EDS). Crystal accumulation did not affect the rate of hydrogen production in struvite reactors. The rate of struvite crystallization (g/m 2-h) and hydrogen production (m 3/m 3-d) were shown to be dependent on applied voltage and cathode material. Overall energy efficiencies (substrate and electricity) were high (73±4%) and not dependent on applied voltage. These results show that MESCs may be useful both as a method for hydrogen gas and struvite production. © 2011 Elsevier Ltd.

  18. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  19. Chamber for Aerosol Deposition of Bioparticles

    Science.gov (United States)

    Kern, Roger; Kirschner, Larry

    2008-01-01

    accumulation of electric charge on them, they are spray-coated with an anti-static material. During use, the base plate and the sides and top of the chamber are grounded as a further measure to minimize the buildup of electric charge.

  20. A Customizable Chamber for Measuring Cell Migration.

    Science.gov (United States)

    Chowdhury, Aniqa N; Vo, Huu Tri; Olang, Sharon; Mappus, Elliott; Peterson, Brian; Hlavac, Nora; Harvey, Tyler; Dean, Delphine

    2017-03-12

    Cell migration is a vital part of immune responses, growth, and wound healing. Cell migration is a complex process that involves interactions between cells, the extracellular matrix, and soluble and non-soluble chemical factors (e.g., chemoattractants). Standard methods for measuring the migration of cells, such as the Boyden chamber assay, work by counting cells on either side of a divider. These techniques are easy to use; however, they offer little geometric modification for different applications. In contrast, microfluidic devices can be used to observe cell migration with customizable concentration gradients of soluble factors 1 , 2 . However, methods for making microfluidics based assays can be difficult to learn. Here, we describe an easy method for creating cell culture chambers to measure cell migration in response to chemical concentration gradients. Our cell migration chamber method can create different linear concentration gradients in order to study cell migration for a variety of applications. This method is relatively easy to use and is typically performed by undergraduate students. The microchannel chamber was created by placing an acrylic insert in the shape of the final microchannel chamber well into a Petri dish. After this, poly(dimethylsiloxane) (PDMS) was poured on top of the insert. The PDMS was allowed to harden and then the insert was removed. This allowed for the creation of wells in any desired shape or size. Cells may be subsequently added to the microchannel chamber, and soluble agents can be added to one of the wells by soaking an agarose block in the desired agent. The agarose block is added to one of the wells, and time-lapse images can be taken of the microchannel chamber in order to quantify cell migration. Variations to this method can be made for a given application, making this method highly customizable.

  1. Monitoring methods of drift chamber characteristics. Application to SPES III detection

    International Nuclear Information System (INIS)

    Kerboul, C.

    1984-05-01

    For the SPES III spectrometer at the Laboratoire National Saturne, a large detection system has been developed which consists of three drift chambers for localization of the particle trajectories. Performances of these detectors for high spatial resolution depend greatly on different parameters such as anode current, gas mixture, drift velocity, efficiency, etc. The present work summarizes a set of methods necessary to the control of these parameters, for achieving the high resolution essentiel for the nuclear physic at intermediate energy [fr

  2. Fitting methods for constructing energy-dependent efficiency curves and their application to ionization chamber measurements

    International Nuclear Information System (INIS)

    Svec, A.; Schrader, H.

    2002-01-01

    An ionization chamber without and with an iron liner (absorber) was calibrated by a set of radionuclide activity standards of the Physikalisch-Technische Bundesanstalt (PTB). The ionization chamber is used as a secondary standard measuring system for activity at the Slovak Institute of Metrology (SMU). Energy-dependent photon-efficiency curves were established for the ionization chamber in defined measurement geometry without and with the liner, and radionuclide efficiencies were calculated. Programmed calculation with an analytical efficiency function and a nonlinear regression algorithm of Microsoft (MS) Excel for fitting was used. Efficiencies from bremsstrahlung of pure beta-particle emitters were calibrated achieving a 10% accuracy level. Such efficiency components are added to obtain the total radionuclide efficiency of photon emitters after beta decay. The method yields differences of experimental and calculated radionuclide efficiencies for most of the photon-emitting radionuclides in the order of a few percent

  3. Growing and analyzing biofilms in flow chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....

  4. Temperature Impact on the Forage Quality of Two Wheat Cultivars with Contrasting Capacity to Accumulate Sugars

    Directory of Open Access Journals (Sweden)

    Máximo Lorenzo

    2015-08-01

    Full Text Available Wheat is increasingly used as a dual-purpose crop (for forage and grain production worldwide. Plants encounter low temperatures in winter, which commonly results in sugar accumulation. High sugar levels might have a positive impact on forage digestibility, but may also lead to an increased risk of bloat. We hypothesized that cultivars with a lower capacity to accumulate sugars when grown under cold conditions may have a lower bloat risk than higher sugar-accumulating genotypes, without showing significantly lower forage digestibility. This possibility was studied using two wheat cultivars with contrasting sugar accumulation at low temperature. A series of experiments with contrasting temperatures were performed in controlled-temperature field enclosures (three experiments and growth chambers (two experiments. Plants were grown at either cool (8.1 °C–9.3 °C or warm (15.7 °C–16.5 °C conditions in field enclosures, and at either 5 °C or 25 °C in growth chambers. An additional treatment consisted of transferring plants from cool to warm conditions in the field enclosures and from 5 °C to 25 °C in the growth chambers. The plants in the field enclosure experiments were exposed to higher irradiances (i.e., 30%–100% than those in the growth chambers. Our results show that (i low temperatures led to an increased hemicellulose content, in parallel with sugar accumulation; (ii low temperatures produced negligible changes in in vitro dry matter digestibility while leading to a higher in vitro rumen gas production, especially in the higher sugar-accumulating cultivar; (iii transferring plants from cool to warm conditions led to a sharp decrease in in vitro rumen gas production in both cultivars; and (iv light intensity (in contrast to temperature appeared to have a lower impact on forage quality.

  5. Long-term performance of double gap resistive plate chambers under gamma irradiation

    International Nuclear Information System (INIS)

    Abbrescia, M.; Colaleo, A.; Guarrasi, L.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Romano, F.; Altieri, S.; Belli, G.; Bruno, G.; Gianini, G.; Ratti, S.P.; Riccardi, C.; Torre, P.; Viola, L.; Vitulo, P.

    2002-01-01

    In this paper, we describe a dedicated test to study possible long-term aging effects on Resistive Plate Chambers (RPCs). A double gap detector was operated under gamma irradiation for a period approximately equal to 10 years of LHC in the CMS-barrel region: an integrated dose of about 1.6 Gy and a total charge of about 0.05 C/cm 2 gap were accumulated on the chamber. The results show no relevant aging effect. Also the RPC sensitivity to 60 Co gamma energies is measured

  6. Correction factors for the NMi free-air ionization chamber for medium-energy x-rays calculated with the Monte Carlo method

    International Nuclear Information System (INIS)

    Grimbergen, T.W.M.; Dijk, E. van; Vries, W. de

    1998-01-01

    A new method is described for the determination of x-ray quality dependent correction factors for free-air ionization chambers. The method is based on weighting correction factors for mono-energetic photons, which are calculated using the Monte Carlo method, with measured air kerma spectra. With this method, correction factors for electron loss, scatter inside the chamber and transmission through the diaphragm and front wall have been calculated for the NMi free-air chamber for medium-energy x-rays for a wide range of x-ray qualities in use at NMi. The newly obtained correction factors were compared with the values in use at present, which are based on interpolation of experimental data for a specific set of x-ray qualities. For x-ray qualities which are similar to this specific set, the agreement between the correction factors determined with the new method and those based on the experimental data is better than 0.1%, except for heavily filtered x-rays generated at 250 kV. For x-ray qualities dissimilar to the specific set, differences up to 0.4% exist, which can be explained by uncertainties in the interpolation procedure of the experimental data. Since the new method does not depend on experimental data for a specific set of x-ray qualities, the new method allows for a more flexible use of the free-air chamber as a primary standard for air kerma for any x-ray quality in the medium-energy x-ray range. (author)

  7. A magnetically levitated electrode ionization chamber of the noncontact measurement type

    International Nuclear Information System (INIS)

    Kawaguchi, Toshiro; Yoshimura, Atsushi

    2002-01-01

    A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the γ-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ionization current when accumulated for 1 h is about 1.3x10 -17 A

  8. A magnetically levitated electrode ionization chamber of the noncontact measurement type

    CERN Document Server

    Kawaguchi, T

    2002-01-01

    A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the gamma-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ionization current when accumulated for 1 h is a...

  9. PWCs and drift chambers at ISABELLE

    International Nuclear Information System (INIS)

    Okuno, H.; Teramoto, Y.; Wheeler, C.D.

    1978-01-01

    Rate effects in proportional chambers and drift chambers are addressed first. The widely used high-gas-gain chambers would have impaired performance at ISABELLE data rates. Improvement can be expected with lower gas gain, and this possibility is investigated with respect to position and time resolution. Results on chamber lifetime are summarized; space-charge effects, gain saturation, and radiation hardness of electronics are considered. The resolution of drift chambers is discussed in some detail; time resolution, double pulse resolution, and momentum resolution and multiple scattering are included. The expected high multiplicity of tracks from a single event, the high event rates, and the requirement for low gas gain necessitate revision of the methods for measuring the second coordinate. Known methods of two-dimensional point localization are summarized according to spatial accuracy, electronics requirements, and multihit capability. Delay lines, charge division, and cathode strips are considered. Particle identification by means of measurement of the relativistic rise of energy loss by conventional and unconventional means was investigated. 32 references, 3 figures, 4 tables

  10. Evaluation of a special pencil ionization chamber by the Monte Carlo method

    International Nuclear Information System (INIS)

    Mendonca, Dalila; Neves, Lucio P.; Perini, Ana P.

    2015-01-01

    A special pencil type ionization chamber, developed at the Instituto de Pesquisas Energeticas e Nucleares, was characterized by means of Monte Carlo simulation to determine the influence of its components on its response. The main differences between this ionization chamber and commercial ionization chambers are related to its configuration and constituent materials. The simulations were made employing the MCNP-4C Monte Carlo code. The highest influence was obtained for the body of PMMA: 7.0%. (author)

  11. Long-term performance of double gap resistive plate chambers under gamma irradiation

    CERN Document Server

    Abbrescia, M; Guarrasi, L; Iaselli, Giuseppe; Loddo, F; Maggi, M; Marangelli, B; Natali, S; Nuzzo, S; Pugliese, G; Ranieri, A; Romano, F; Altieri, S; Belli, G; Bruno, G; Gianini, G; Ratti, S P; Riccardi, C; Torre, P; Viola, L; Vitulo, P

    2002-01-01

    In this paper, we describe a dedicated test to study possible long- term aging effects on Resistive Plate Chambers (RPCs). A double gap detector was operated under gamma irradiation for a period approximately equal to 10 years of LHC in the CMS-barrel region: an integrated dose of about 1.6 Gy and a total charge of about 0.05 C/cm /sup 2/ gap were accumulated on the chamber. The results show no relevant aging effect. Also the RPC sensitivity to /sup 60/Co gamma energies is measured. (9 refs).

  12. Long-term performance of double gap resistive plate chambers under gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M.; Colaleo, A.; Guarrasi, L.; Iaselli, G.; Loddo, F.; Maggi, M.; Marangelli, B.; Natali, S.; Nuzzo, S.; Pugliese, G. E-mail: gabriella.pugliese@ba.infn.it; Ranieri, A.; Romano, F.; Altieri, S.; Belli, G.; Bruno, G.; Gianini, G.; Ratti, S.P.; Riccardi, C.; Torre, P.; Viola, L.; Vitulo, P

    2002-01-21

    In this paper, we describe a dedicated test to study possible long-term aging effects on Resistive Plate Chambers (RPCs). A double gap detector was operated under gamma irradiation for a period approximately equal to 10 years of LHC in the CMS-barrel region: an integrated dose of about 1.6 Gy and a total charge of about 0.05 C/cm{sup 2} gap were accumulated on the chamber. The results show no relevant aging effect. Also the RPC sensitivity to {sup 60}Co gamma energies is measured.

  13. Construction of vacuum system for Tristan accumulation ring

    International Nuclear Information System (INIS)

    Ishimaru, H.; Horikoshi, G.; Kobayashi, M.; Kubo, T.; Mizuno, H.; Momose, T.; Narushima, K.; Watanabe, H.; Yamaguchi, H.

    1983-01-01

    An all aluminum-alloy vacuum system for the TRISTAN accumulation ring is now under construction. Aluminum and aluminum alloys are preferred materials for ultrahigh vacuum systems of large electron storage rings because of their good thermal conductivity, extremely low outgassing rate, and low residual radioactivity. Vacuum beam chambers for the dipole and quadrupole magnets are extruded using porthole dies. The aluminum alloy 6063-T6 provides superior performance in extrusion. For ultrahigh vacuum performance, a special extrusion technique is applied which, along with the outgassing procedure used, is described in detail. Aluminum alloy 3004 seamless elliptical bellows are inserted between the dipole and quadrupole magnet chambers. These bellows are produced by the hydraulic forming of a seamless tube. The seamless bellows and the beam chambers are joined by fully automatic welding. The ceramic chambers for the kicker magnets, the fast bump magnets, and the slow beam intensity monitor are inserted in the aluminum alloy beam chambers. The ceramic chamber (98% alumina) and elliptical bellows are brazed with brazing sheets (4003-3003-4003) in a vacuum furnace. The brazing technique is described. The inner surface of the ceramic chamber is coated with a TiMo alloy by vacuum evaporation to permit a smooth flow of the RF wall current. Other suitable aluminum alloy components, including fittings, feedthroughs, gauges, optical windows, sputter ion pumps, turbomolecular pumps, and valves have been developed; their fabrication is described

  14. Simulated Field Trials Using an Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  15. Simulated Field Trials Using An Indoor Aerosol Test Chamber

    National Research Council Canada - National Science Library

    Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M

    2004-01-01

    .... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...

  16. Absorbed dose measurement by using tissue equivalent ionization chamber (pair ionization chamber) in the Yayoi reactor

    International Nuclear Information System (INIS)

    Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki

    1998-01-01

    Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)

  17. Dorsal skinfold chamber models in mice

    Directory of Open Access Journals (Sweden)

    Schreiter, Jeannine

    2017-07-01

    Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter

  18. Estimation of Bio-Accumulation by a Group Contribution Method

    International Nuclear Information System (INIS)

    Belhachem, B.; Canselier, J. P.

    2009-01-01

    The majority of organic pollutants, after their dispersion in water then their ingestion, have a strong tendency to accumulate in greases. That is due to the hydrophobic character of these molecules. To have an idea on the capacity of a substance to accumulate in the alive beings according to their lipidic mass, the modeling of the pollutant behaviour was made by considering its partition coefficient between n-octanol (representing the lipidic mass) and water. Its knowledge represents a very significant information for the petrochemical and the pharmaceutical industries. To dissipate any doubt about confidence concerning the obtained results, it is considered useful to check the effectiveness of UNIFAC method on the monomethylbenzoic acid such as, for example, the 3-methylbenzoic acid whose n-octanol-water partition coefficient is already listed in the literature.The small deviations observed between the n-octanol-water partition coefficients listed in the literature and the one calculated according UNIFAC method encouraged us to apply it in order to predict the n-octanol-water partition coefficient of the dimethylbenzoic acid. (author)

  19. Method for sequentially processing a multi-level interconnect circuit in a vacuum chamber

    Science.gov (United States)

    Routh, D. E.; Sharma, G. C. (Inventor)

    1984-01-01

    An apparatus is disclosed which includes a vacuum system having a vacuum chamber in which wafers are processed on rotating turntables. The vacuum chamber is provided with an RF sputtering system and a dc magnetron sputtering system. A gas inlet introduces various gases to the vacuum chamber and creates various gas plasma during the sputtering steps. The rotating turntables insure that the respective wafers are present under the sputtering guns for an average amount of time such that consistency in sputtering and deposition is achieved. By continuous and sequential processing of the wafers in a common vacuum chamber without removal, the adverse affects of exposure to atmospheric conditions are eliminated providing higher quality circuit contacts and functional device.

  20. Simultaneous hit finding and timing method for pulse shape analysis of drift chamber signals

    Energy Technology Data Exchange (ETDEWEB)

    Schaile, D; Schaile, O; Schwarz, J

    1986-01-01

    An algorithm for the analysis of the digitized signal waveform of drift chamber pulses is described which yields a good multihit resolution and an accurate drift time determination with little processing time. The method has been tested and evaluated with measured pulse shapes from the full size prototype of the OPAL central detector which were digitized by 100 MHz FADCs. (orig.).

  1. Simultaneous hit finding and timing method for pulse shape analysis of drift chamber signals

    Energy Technology Data Exchange (ETDEWEB)

    Schaile, D; Schaile, O; Schwarz, J

    1986-01-01

    An algorithm for the analysis of the digitized signal waveform of drift chamber pulses is described which yields a good multihit resolution and an accurate drift time determination with little processing time. The method has been tested and evaluated with measured pulse shapes from the full size prototype of the OPAL central detector which were digitized by 100 MHz FADCs.

  2. Biases of chamber methods for measuring soil CO2 efflux demonstrated with a laboratory apparatus.

    Science.gov (United States)

    S. Mark Nay; Kim G. Mattson; Bernard T. Bormann

    1994-01-01

    Investigators have historically measured soil CO2 efflux as an indicator of soil microbial and root activity and more recently in calculations of carbon budgets. The most common methods estimate CO2 efflux by placing a chamber over the soil surface and quantifying the amount of CO2 entering the...

  3. Space shuttle orbit maneuvering engine reusable thrust chamber program

    Science.gov (United States)

    Senneff, J. M.

    1975-01-01

    Reusable thrust chamber and injector concepts were evaluated for the space shuttle orbit maneuvering engine (OME). Parametric engine calculations were carried out by computer program for N2O4/amine, LOX/amine and LOX/hydrocarbon propellant combinations for engines incorporating regenerative cooled and insulated columbium thrust chambers. The calculation methods are described including the fuel vortex film cooling method of combustion gas temperature control, and performance prediction. A method of acceptance of a regeneratively cooled heat rejection reduction using a silicone oil additive was also demonstrated by heated tube heat transfer testing. Regeneratively cooled thrust chamber operation was also demonstrated where the injector was characterized for the OME application with a channel wall regenerative thrust chamber. Bomb stability testing of the demonstration chambers/injectors demonstrated recovery for the nominal design of acoustic cavities. Cavity geometry changes were also evaluated to assess their damping margin. Performance and combustion stability was demonstrated of the originally developed 10 inch diameter combustion pattern operating in an 8 inch diameter thrust chamber.

  4. Clean-up system for pool water in pressure suppression chamber and operation method therefor

    Energy Technology Data Exchange (ETDEWEB)

    Hirabayashi, Kentaro; Kinoshita, Shoichiro

    1996-09-17

    Pool water in a pressure suppression chamber of a BWR type reactor is sucked by a pump of an after-heat removing system. The pool water pressurized here is sent to the pressure suppression chamber by way of a heat exchanger and a test line backwarding pipeline to stir the pool water in the pressure suppression chamber. Further, the pool water pressurized by the pump is sent to the pressure suppression chamber by way of a filtration desalting device and an exit pipe to purify the pool water. Upon cleaning of pipelines before the start of a periodical test, the pool water sucked by the pump is sent to the filtration desalting device and recovered to the pressure suppression chamber. This can reduce the amount of impurities carried to the suppression chamber. After the cleaning of the pipelines, pool water is passed through the test line backwarding pipeline, so that the pool water can be stirred at the same time. (I.N.)

  5. Percutaneous window chamber method for chronic intravital microscopy of sensor-tissue interactions.

    Science.gov (United States)

    Koschwanez, Heidi E; Klitzman, Bruce; Reichert, W Monty

    2008-11-01

    A dorsal, two-sided skin-fold window chamber model was employed previously by Gough in glucose sensor research to characterize poorly understood physiological factors affecting sensor performance. We have extended this work by developing a percutaneous one-sided window chamber model for the rodent dorsum that offers both a larger subcutaneous area and a less restrictive tissue space than previous animal models. A surgical procedure for implanting a sensor into the subcutis beneath an acrylic window (15 mm diameter) is presented. Methods to quantify changes in the microvascular network and red blood cell perfusion around the sensors using noninvasive intravital microscopy and laser Doppler flowmetry are described. The feasibility of combining interstitial glucose monitoring from an implanted sensor with intravital fluorescence microscopy was explored using a bolus injection of fluorescein and dextrose to observe real-time mass transport of a small molecule at the sensor-tissue interface. The percutaneous window chamber provides an excellent model for assessing the influence of different sensor modifications, such as surface morphologies, on neovascularization using real-time monitoring of the microvascular network and tissue perfusion. However, the tissue response to an implanted sensor was variable, and some sensors migrated entirely out of the field of view and could not be observed adequately. A percutaneous optical window provides direct, real-time images of the development and dynamics of microvascular networks, microvessel patency, and fibrotic encapsulation at the tissue-sensor interface. Additionally, observing microvessels following combined bolus injections of a fluorescent dye and glucose in the local sensor environment demonstrated a valuable technique to visualize mass transport at the sensor surface.

  6. Investigation of elements accumulation in some plants by nuclear-research methods

    International Nuclear Information System (INIS)

    Azhabov, A.K.; Khushmuradov, Sh.Kh.; Danilova, E.A.; Kist, A.A.; Dekhkanov, T.; Kobzev, A.P.; Muminov, I.T.

    2000-01-01

    The results of studies on 18 elements in the samples of hugh elecampane, middle-asian mint, field horsetail, mixed grass crop and turkestan dog rose fruits, collected at the two stationary sites A and B of the Bashkizylsaj area of the Chatkalsk biospheric reservation and studied through the neutron-activation (n), γ-activation (γ), X-ray spectral (p) and X-ray fluorescence (x) physical methods, are presented. The root-square errors of the results, obtained by different method and differences in the elements accumulation, depending on the plant type, their part and vegetation place, are evaluated. The coefficients of biological accumulation of 15 elements in the 15 plants under study are determined on the basis of the data on the elements content in plants and corresponding soil samples [ru

  7. The discussion on a new measure method of radon chamber leak rate

    International Nuclear Information System (INIS)

    Zhang Junkui; Tang Bing

    2010-01-01

    Radon chamber is the third standard radon source. The leak rate is the key parameter for the radon chamber to naturally and safely operate. One way, that measure the leak rate is introduced. The experience result is that the way is simple and veracious to measure the leak rate. (authors)

  8. Validation of the flow-through chamber (FTC and steady-state (SS methods for clearance rate measurements in bivalves

    Directory of Open Access Journals (Sweden)

    Poul S. Larsen

    2011-09-01

    To obtain precise and reliable laboratory clearance rate (filtration rate measurements with the ‘flow-through chamber method’ (FTC the design must ensure that only inflow water reaches the bivalve's inhalant aperture and that exit flow is fully mixed. As earlier recommended these prerequisites can be checked by a plot of clearance rate (CR versus increasing through-flow (Fl to reach a plateau, which is the true CR, but we also recommend to plot percent particles cleared versus reciprocal through-flow where the plateau becomes the straight line CR/Fl, and we emphasize that the percent of particles cleared is in itself neither a criterion for valid CR measurement, nor an indicator of appropriate ‘chamber geometry’ as hitherto adapted in many studies. For the ‘steady-state method’ (SS, the design must ensure that inflow water becomes fully mixed with the bivalve's excurrent flow to establish a uniform chamber concentration prevailing at its incurrent flow and at the chamber outlet. These prerequisites can be checked by a plot of CR versus increasing Fl, which should give the true CR at all through-flows. Theoretically, the experimental uncertainty of CR for a given accuracy of concentration measurements depends on the percent reduction in particle concentration (100×P from inlet to outlet of the ideal ‘chamber geomety’. For FTC, it decreases with increasing values of P while for SS it first decreases but then increases again, suggesting the use of an intermediate value of P. In practice, the optimal value of P may depend on the given ‘chamber geometry’. The fundamental differences between the FTC and the SS methods and practical guidelines for their use are pointed out, and new data on CR for the blue mussel, Mytilus edulis, illustrate a design and use of the SS method which may be employed in e.g. long-term growth experiments at constant algal concentrations.

  9. Portable automation of static chamber sample collection for quantifying soil gas flux

    Science.gov (United States)

    The collection of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled in a given time period is limited by the spacing between chambers and the availability of trained research technicians. However, the static chamber method can limit spatial ...

  10. Simulation of the Interaction of X-rays with a Gas in an Ionization Chamber by the Monte Carlo Method

    International Nuclear Information System (INIS)

    Grau Carles, A.; Garcia Gomez-Tejedor, G.

    2001-01-01

    The final objective of any ionization chamber is the measurement of the energy amount or radiation dose absorbed by the gas into the chamber. The final value depends on the composition of the gas, its density and temperature, the ionization chamber geometry, and type and intensity of the radiation. We describe a Monte Carlo simulation method, which allows one to compute the dose absorbed by the gas for a X-ray beam. Verification of model has been carried out by simulating the attenuation of standard X-ray radiation through the half value layers established in the ISO 4037 report, while assuming a Weibull type energy distribution for the incident photons. (Author) 6 refs

  11. Ionization chamber

    International Nuclear Information System (INIS)

    Jilbert, P.H.

    1975-01-01

    The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)

  12. Acid aerosol measurement method intercomparisons: An outdoor smog chamber study

    International Nuclear Information System (INIS)

    Ellestad, T.G.; Barnes, H.M.; Kamens, R.M.; McDow, S.R.; Sickles, J.E. II; Hodson, L.L.; Waldman, J.M.; Randtke, S.J.; Lane, D.D.; Springston, S.R.; Koutrakis, P.; Thurston, G.D.

    1991-01-01

    A workshop on the measurement of acid aerosols indicated that the sampling methods in use had not been intercompared. Following two laboratory pilot studies, EPA sponsored tests in an outdoor smog chamber with a variety of test aerosols, including sulfuric acid only, photochemical smog with added sulfuric acid, photo-chemical smog with added sulfuric acid and dust, and dust followed by photochemical smog with added sulfuric acid. Two experiments of each type were conducted. Six groups, several of which were active in ambient acid aerosol measurements, participated by operating duplicate samplers for each experiment. Five groups employed a similar method, in which ammonia is removed from the sample stream by diffusion, particles are removed by Teflon filter, and hydrogen ion on the Teflon filter is determined by pH electrode. However, differences existed in the method's implementation among groups in physical design, flow rate, procedures, and analysis. The sixth group's method did not use a diffusion denuder for ammonia and had several other important differences. Besides hydrogen ion, seven other species were reported by most of the groups, including particle phase sulfate, ammonium, and nitrate, and gas phase sulfur dioxide, ammonia, nitric acid, and nitrous acid. Results of the inter-comparison will be presented

  13. A re-circulated toxicity exposure chamber to evaluate hydrocarbon dispersions

    International Nuclear Information System (INIS)

    Fuller, C.B.; Bonner, J.S.; Bujnoch, J.D.; Ussery, S.F.; Arrambide, G.; Sterling, M.C.

    2002-01-01

    Traditional toxicology methods are not suitable for evaluating chemically dispersed oil which exists mostly as a colloidal suspension and as dissolved fractions. A new toxicity exposure chamber was designed with separate chambers for scaled mixing and organism exposure. The design of the chamber incorporates continuous recirculation between the mixing and exposure chamber and an upward flow in the exposure chamber. The toxicity exposure system incorporates scalable and quantitative mixing inputs with real time particle size analysis and traditional petrochemistry methods to characterize the exposure regime. Changes in dispersion were successfully translated to the organism exposure regime. The study determined the petroleum toxicity with a juvenile marine test species. Low control mortality demonstrated the usefulness of the method for testing toxicity of colloidal oil suspensions. 20 refs., 1 tab., 4 figs

  14. Comparison between calibration methods of ionization chamber type pencil in greatness P_K_L

    International Nuclear Information System (INIS)

    Macedo, E.M.; Pereira, L.C.S.; Ferreira, M.J.; Navarro, V.C.C.; Garcia, I.F.M.; Pires, E.J.; Navarro, M.V.T.

    2016-01-01

    Calibration of radiation meters is indispensable on Quality Assurance Program in Radiodiagnostic procedures, mainly Computed Tomography. Thus, this study aims evaluate two calibration methods of pencil ionization chambers in terms of Kerma-length Product (P_K_L) (a direct substitution method and an indirect one, through Kerma and length measurements). The results showed a good equivalence, with minimal concordance of 98,5% between calibration factors. About uncertainties, both showed similar results (substitution 2.2% and indirect 2.3%), indicating that the last one is better, due the costs reduction to implant this calibration procedure. (author)

  15. Realization of radioactive equilibrium in the KRISS radon chamber

    International Nuclear Information System (INIS)

    Lee, Mo Sung; Park, Tae Soon; Lee, Jong Man

    2013-01-01

    The maintenance of radioactive equilibrium between radon and its decay products in a radon chamber is necessary to calibrate radon decay product monitors. In this study, the activity concentrations of radon decay products have been measured, and mosquito-repellent incense has been used to produce aerosol particles in the chamber. Filter papers with 8 μm pore size were used to collect aerosol in the chamber. The activity concentrations of radon decay products have been evaluated by the Modified Tsivoglou Method. The correction factors due to the differences in counting time requirements of the Modified Tsivoglou Method and the time delay between consecutive measurements have been determined. Finally, the radioactive equilibrium has been confirmed by applying the Bateman equation. - Highlights: • The activity concentrations of radon decay products are evaluated by the Modified Tsivoglou Method. • Mosquito-repellent incense is used to produce aerosol particles in the radon chamber. • The radioactive equilibrium in the chamber was achieved within 2 days and confirmed by the Bateman equation

  16. Relative proportions of polycyclic aromatic hydrocarbons differ between accumulation bioassays and chemical methods to predict bioavailability

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Eyles, Jose L., E-mail: j.l.gomezeyles@reading.ac.u [University of Reading, School of Human and Environmental Sciences, Department of Soil Science, Reading RG6 6DW, Berkshire (United Kingdom); Collins, Chris D.; Hodson, Mark E. [University of Reading, School of Human and Environmental Sciences, Department of Soil Science, Reading RG6 6DW, Berkshire (United Kingdom)

    2010-01-15

    Chemical methods to predict the bioavailable fraction of organic contaminants are usually validated in the literature by comparison with established bioassays. A soil spiked with polycyclic aromatic hydrocarbons (PAHs) was aged over six months and subjected to butanol, cyclodextrin and tenax extractions as well as an exhaustive extraction to determine total PAH concentrations at several time points. Earthworm (Eisenia fetida) and rye grass root (Lolium multiflorum) accumulation bioassays were conducted in parallel. Butanol extractions gave the best relationship with earthworm accumulation (r{sup 2} <= 0.54, p <= 0.01); cyclodextrin, butanol and acetone-hexane extractions all gave good predictions of accumulation in rye grass roots (r{sup 2} <= 0.86, p <= 0.01). However, the profile of the PAHs extracted by the different chemical methods was significantly different (p < 0.01) to that accumulated in the organisms. Biota accumulated a higher proportion of the heavier 4-ringed PAHs. It is concluded that bioaccumulation is a complex process that cannot be predicted by measuring the bioavailable fraction alone. - The ability of chemical methods to predict PAH accumulation in Eisenia fetida and Lolium multiflorum was hindered by the varied metabolic fate of the different PAHs within the organisms.

  17. Glove box chamber

    International Nuclear Information System (INIS)

    Cox, M.E.; Cox, M.E.

    1975-01-01

    An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)

  18. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  19. A numerical method for investigating crystal settling in convecting magma chambers

    Science.gov (United States)

    Verhoeven, J.; Schmalzl, J.

    2009-12-01

    Magma chambers can be considered as thermochemically driven convection systems. We present a new numerical method that describes the movement of crystallized minerals in terms of active spherical particles in a convecting magma that is represented by an infinite Prandtl number fluid. The main part focuses on the results we obtained. A finite volume thermochemical convection model for two and three dimensions and a discrete element method, which is used to model granular material, are combined. The new model is validated with floating experiments using particles of different densities and an investigation of single and multiparticle settling velocities. The resulting velocities are compared with theoretical predictions by Stokes's law and a hindered settling function for the multiparticle system. Two fundamental convection regimes are identified in the parameter space that is spanned by the Rayleigh number and the chemical Rayleigh number, which is a measure for the density of the particles. We define the T regime that is dominated by thermal convection. Here the thermal driving force is strong enough to keep all particles in suspension. As the particles get denser, they start settling to the ground, which results in a C regime. The C regime is characterized by the existence of a sediment layer with particle-rich material and a suspension layer with few particles. It is shown that the presence of particles can reduce the vigor of thermal convection. In the frame of a parameter study we discuss the change between the regimes that is systematically investigated. We show that the so-called TC transition fits a power law. Furthermore, we investigate the settling behavior of the particles in vigorous thermal convection, which can be linked to crystal settling in magma chambers. We develop an analytical settling law that describes the number of settled particles against time and show that the results fit the observations from numerical and laboratory experiments.

  20. Monitored Drift Chambers in the ATLAS Detector

    CERN Multimedia

    Herten, G

    Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...

  1. Test chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2009-01-01

    A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in

  2. Experimental determination of pcav factors for cylindrical ionisation chambers in electron beams

    International Nuclear Information System (INIS)

    Palm, Aa.; Mattsson, O.

    2000-01-01

    The electron beam method recommended for calibrating plane parallel ionisation chambers involves cavity correction factors for cylindrical chambers. The cavity correction factors in the IAEA TRS-381 Code of Practice are based on measurements at R 100 in a PMMA phantom using PMMA cylindrical chambers having different cavity radii. In the present work the recommended data were confirmed for electron beams delivered by modern medical accelerators by using the very same phantom and ionisation chambers that were used in the original work. From another series of measurements, using four specially designed wall-less chambers in a graphite phantom, the linear relation between p cav and the chamber radius that is the basis for the experimental method, was verified. The method was also used to determine the cavity correction factors for a set of Farmer-like graphite chambers placed in water. Compared to the TRS-381 Code of Practice a smaller correction was found for the cavity perturbation for the graphite chambers used in water. (author)

  3. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...... a differential equation applying several simplifications and approximations leading to discrepancies between theory and experiments [3]. The theory predicts the collection efficiency as a function of the electrical field and was applied for both air filled ionization chambers and liquid filled ionization...... chambers. For liquids the LET can be roughly deduced from the collection efficiency dependency on the electrical field inside a liquid ionization chambers [4] using an extrapolation method. We solved the fundamental differential equation again presented by Jaffe numerically, but now taking into account...

  4. A new method of alpha ray measurement using a Quadrupole Mass Spectrometer

    International Nuclear Information System (INIS)

    Iwata, Y.; Inoue, Y.; Minowa, M.

    2007-01-01

    We propose a new method of alpha (α)-ray measurement that detects helium atoms with a Quadrupole Mass Spectrometer (QMS). A demonstration is undertaken with a plastic-covered 241 Am α-emitting source to detect α-rays stopped in the capsule. We successfully detect helium atoms that diffuse out of the capsule by accumulating them for 1-20h in a closed chamber. The detected amount is found to be proportional to the accumulation time. Our method is applicable to probe α-emitting radioactivity in bulk material

  5. Characteristic parameters of drift chambers calculation

    International Nuclear Information System (INIS)

    Duran, I.; Martinez-Laso, L.

    1989-01-01

    We present here the methods we used to analyse the characteristic parameters of drift chambers. The algorithms to calculate the electric potential in any point for any drift chamber geometry are presented. We include the description of the programs used to calculate the electric field, the drift paths, the drift velocity and the drift time. The results and the errors are discussed. (Author) 7 refs

  6. Growing and Analyzing Biofilms in Flow Chambers

    DEFF Research Database (Denmark)

    Tolker-Nielsen, Tim; Sternberg, Claus

    2011-01-01

    This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....

  7. National Ignition Facility Target Chamber

    International Nuclear Information System (INIS)

    Wavrik, R W; Cox, J R; Fleming, P J

    2000-01-01

    On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was

  8. The Mobile Chamber

    Science.gov (United States)

    Scharfstein, Gregory; Cox, Russell

    2012-01-01

    A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

  9. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1980-01-01

    A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)

  10. Cardiac chamber scintiscanning

    International Nuclear Information System (INIS)

    Goretzki, G.

    1981-01-01

    The two methods of cardiac chamber scintiscanning, i.e. 'first pass' and 'ECG-triggered' examinations, are explained and compared. Two tables indicate the most significant radiation doses of the applied radio tracers, i.e. 99m-Tc-pertechnetate and 99m-Tc-HSA, to which a patient is exposed. These averaged values are calculated from various data given in specialised literature. On the basis of data given in literature, an effective half-life of approximately 5 hours in the intravascular space was calculated for the erythrocytes labelled with technetium 99m. On this basis, the radiation doses for the patients due to 99m-Tc-labelled erythrocytes are estimated. The advantages and disadvantages of the two methods applied for cardiac chamber scintiscanning are put into contrast and compared with the advantages and disadvantages of the quantitative X-ray cardiography of the left heart. The still existing problems connected with the assessment of ECG-triggered images are discussed in detail. The author performed investigations of his own, which concerned the above-mentioned problems. (orig./MG) [de

  11. Doriot Climatic Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...

  12. Ionization chamber

    International Nuclear Information System (INIS)

    1977-01-01

    An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  13. TH-E-BRE-03: A Novel Method to Account for Ion Chamber Volume Averaging Effect in a Commercial Treatment Planning System Through Convolution

    International Nuclear Information System (INIS)

    Barraclough, B; Li, J; Liu, C; Yan, G

    2014-01-01

    Purpose: Fourier-based deconvolution approaches used to eliminate ion chamber volume averaging effect (VAE) suffer from measurement noise. This work aims to investigate a novel method to account for ion chamber VAE through convolution in a commercial treatment planning system (TPS). Methods: Beam profiles of various field sizes and depths of an Elekta Synergy were collected with a finite size ion chamber (CC13) to derive a clinically acceptable beam model for a commercial TPS (Pinnacle 3 ), following the vendor-recommended modeling process. The TPS-calculated profiles were then externally convolved with a Gaussian function representing the chamber (σ = chamber radius). The agreement between the convolved profiles and measured profiles was evaluated with a one dimensional Gamma analysis (1%/1mm) as an objective function for optimization. TPS beam model parameters for focal and extra-focal sources were optimized and loaded back into the TPS for new calculation. This process was repeated until the objective function converged using a Simplex optimization method. Planar dose of 30 IMRT beams were calculated with both the clinical and the re-optimized beam models and compared with MapCHEC™ measurements to evaluate the new beam model. Results: After re-optimization, the two orthogonal source sizes for the focal source reduced from 0.20/0.16 cm to 0.01/0.01 cm, which were the minimal allowed values in Pinnacle. No significant change in the parameters for the extra-focal source was observed. With the re-optimized beam model, average Gamma passing rate for the 30 IMRT beams increased from 92.1% to 99.5% with a 3%/3mm criterion and from 82.6% to 97.2% with a 2%/2mm criterion. Conclusion: We proposed a novel method to account for ion chamber VAE in a commercial TPS through convolution. The reoptimized beam model, with VAE accounted for through a reliable and easy-to-implement convolution and optimization approach, outperforms the original beam model in standard IMRT QA

  14. Ionization chamber gradient effects in nonstandard beam configurations

    International Nuclear Information System (INIS)

    Bouchard, Hugo; Seuntjens, Jan; Carrier, Jean-Francois; Kawrakow, Iwan

    2009-01-01

    Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P wall , P stem , and P cel ) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude of

  15. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  16. Study of the replacement correction factors for ionization chamber dosimetry by Monte Carlo simulations

    Science.gov (United States)

    Wang, Lilie

    In ionization chamber radiation dosimetry, the introduction of the ion chamber into medium will unavoidably distort the radiation field near the chamber because the chamber cavity material (air) is different from the medium. A replacement correction factor, Prepl was introduced in order to correct the chamber readings to give an accurate radiation dose in the medium without the presence of the chamber. Generally it is very hard to measure the values of Prepl since they are intertwined with the chamber wall effect. In addition, the P repl values always come together with the stopping-power ratio of the two media involved. This makes the problem of determining the P repl values even more complicated. Monte Carlo simulation is an ideal method to investigate the replacement correction factors. In this study, four different methods of calculating the values of Prepl by Monte Carlo simulation are discussed. Two of the methods are designated as 'direct' methods in the sense that the evaluation of the stopping-power ratio is not necessary. The systematic uncertainties of the two direct methods are estimated to be about 0.1-0.2% which comes from the ambiguous definition of the energy cutoff Delta used in the Spencer-Attix cavity theory. The two direct methods are used to calculate the values of P repl for both plane-parallel chambers and cylindrical thimble chambers in either electron beams or photon beams. The calculation results are compared to measurements. For electron beams, good agreements are obtained. For thimble chambers in photon beams, significant discrepancies are observed between calculations and measurements. The experiments are thus investigated and the procedures are simulated by the Monte Carlo method. It is found that the interpretation of the measured data as the replacement correction factors in dosimetry protocols are not correct. In applying the calculation to the BIPM graphite chamber in a 60Co beam, the calculated values of P repl differ from those

  17. Design and construction of a Vertex Chamber and measurement of the average B-Hadron lifetime

    International Nuclear Information System (INIS)

    Nelson, H.N.

    1987-10-01

    Four parameters describe the mixing of the three quark generations in the Standard Model of the weak charged current interaction. These four parameters are experimental inputs to the model. A measurement of the mean lifetime of hadrons containing b-quarks, or B-Hadrons, constrains the magnitudes of two of these parameters. Measurement of the B-Hadron lifetime requires a device that can measure the locations of the stable particles that result from B-Hadron decay. This device must function reliably in an inaccessible location, and survive high radiation levels. We describe the design and construction of such a device, a gaseous drift chamber. Tubes of 6.9 mm diameter, having aluminized mylar walls of 100 μm thickness are utilized in this Vertex Chamber. It achieves a spatial resolution of 45 μm, and a resolution in extrapolation to the B-Hadron decay location of 87 μm. Its inner layer is 4.6 cm from e + e - colliding beams. The Vertex Chamber is situated within the MAC detector at PEP. We have analyzed botht he 94 pb -1 of integrated luminosity accumulated at √s = 29 GeV with the Vertex Chamber in place as well as the 210 pb -1 accumulated previously. We require a lepton with large momentum transverse to the event thrust axis to obtain a sample of events enriched in B-Hadron decays. The distribution of signed impact parameters of all tracks in these events is used to measure the B-Hadron flight distance, and hence lifetime. 106 refs., 79 figs., 20 tabs

  18. Design and construction of a Vertex Chamber and measurement of the average B-Hadron lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, H.N.

    1987-10-01

    Four parameters describe the mixing of the three quark generations in the Standard Model of the weak charged current interaction. These four parameters are experimental inputs to the model. A measurement of the mean lifetime of hadrons containing b-quarks, or B-Hadrons, constrains the magnitudes of two of these parameters. Measurement of the B-Hadron lifetime requires a device that can measure the locations of the stable particles that result from B-Hadron decay. This device must function reliably in an inaccessible location, and survive high radiation levels. We describe the design and construction of such a device, a gaseous drift chamber. Tubes of 6.9 mm diameter, having aluminized mylar walls of 100 ..mu..m thickness are utilized in this Vertex Chamber. It achieves a spatial resolution of 45 ..mu..m, and a resolution in extrapolation to the B-Hadron decay location of 87 ..mu..m. Its inner layer is 4.6 cm from e/sup +/e/sup -/ colliding beams. The Vertex Chamber is situated within the MAC detector at PEP. We have analyzed botht he 94 pb/sup -1/ of integrated luminosity accumulated at ..sqrt..s = 29 GeV with the Vertex Chamber in place as well as the 210 pb/sup -1/ accumulated previously. We require a lepton with large momentum transverse to the event thrust axis to obtain a sample of events enriched in B-Hadron decays. The distribution of signed impact parameters of all tracks in these events is used to measure the B-Hadron flight distance, and hence lifetime. 106 refs., 79 figs., 20 tabs.

  19. An encoding readout method used for Multi-gap Resistive Plate Chambers (MRPCs) for muon tomography

    Science.gov (United States)

    Yue, X.; Zeng, M.; Wang, Y.; Wang, X.; Zeng, Z.; Zhao, Z.; Cheng, J.

    2014-09-01

    A muon tomography facility has been built in Tsinghua University. Because of the low flux of cosmic muon, an encoding readout method, based on the fine-fine configuration, was implemented for the 2880 channels induced signals from the Multi-gap Resistive Plate Chamber (MRPC) detectors. With the encoding method, the number of the readout electronics was dramatically reduced and thus the complexity and the cost of the facility was reduced, too. In this paper, the details of the encoding method, and the overall readout system setup in the muon tomography facility are described. With the commissioning of the facility, the readout method works well. The spatial resolution of all MRPC detectors are measured with cosmic muon and the preliminary imaging result are also given.

  20. An encoding readout method used for Multi-gap Resistive Plate Chambers (MRPCs) for muon tomography

    International Nuclear Information System (INIS)

    Yue, X; Zeng, M; Wang, Y; Wang, X; Zeng, Z; Zhao, Z; Cheng, J

    2014-01-01

    A muon tomography facility has been built in Tsinghua University. Because of the low flux of cosmic muon, an encoding readout method, based on the fine-fine configuration, was implemented for the 2880 channels induced signals from the Multi-gap Resistive Plate Chamber (MRPC) detectors. With the encoding method, the number of the readout electronics was dramatically reduced and thus the complexity and the cost of the facility was reduced, too. In this paper, the details of the encoding method, and the overall readout system setup in the muon tomography facility are described. With the commissioning of the facility, the readout method works well. The spatial resolution of all MRPC detectors are measured with cosmic muon and the preliminary imaging result are also given

  1. Scalar Similarity for Relaxed Eddy Accumulation Methods

    Science.gov (United States)

    Ruppert, Johannes; Thomas, Christoph; Foken, Thomas

    2006-07-01

    The relaxed eddy accumulation (REA) method allows the measurement of trace gas fluxes when no fast sensors are available for eddy covariance measurements. The flux parameterisation used in REA is based on the assumption of scalar similarity, i.e., similarity of the turbulent exchange of two scalar quantities. In this study changes in scalar similarity between carbon dioxide, sonic temperature and water vapour were assessed using scalar correlation coefficients and spectral analysis. The influence on REA measurements was assessed by simulation. The evaluation is based on observations over grassland, irrigated cotton plantation and spruce forest. Scalar similarity between carbon dioxide, sonic temperature and water vapour showed a distinct diurnal pattern and change within the day. Poor scalar similarity was found to be linked to dissimilarities in the energy contained in the low frequency part of the turbulent spectra ( definition.

  2. Drift Chambers detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez laso, L.

    1989-01-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs

  3. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  4. Physical aspects on the neutron irradiation. 4. Dosimetry with ionization chamber

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi; Takada, Masashi

    2008-01-01

    Absolute measurements of the absorbed dose for irradiation are generally made using ionization chambers, which should be calibrated by the standard radiation source. The neutron dose measurements are not simple since gamma rays always contaminate the neutron flux and a variety of charged particles are induced by neutrons. Following subjects are described: (1) The method by ICRU 45 to estimate total dose of neutrons and gamma ray, (2) The method to measure the neutron dose and the gamma ray dose separately using paired ionization-chambers, and (3) The calibration of ionization chambers. The stability of the standard ionization-chambers is also presented. (K.Y.)

  5. Method for determining correction factors induced by irradiation of ionization chamber cables in large radiation field

    International Nuclear Information System (INIS)

    Rodrigues, L.L.C.

    1988-01-01

    A simple method was developed to be suggested to hospital physicists in order to be followed during large radiation field dosimetry, to evaluate the effects of cables, connectors and extension cables irradiation and to determine correction factors for each system or geometry. All quality control tests were performed according to the International Electrotechnical Commission for three clinical dosimeters. Photon and electron irradiation effects for cables, connectors and extention cables were investigated under different experimental conditions by means of measurements of chamber sensitivity to a standard radiation source of 90 Sr. The radiation induced leakage current was also measured for cables, connectors and extension cables irradiated by photons and electrons. All measurements were performed at standard dosimetry conditions. Finally, measurements were performed in large fields. Cable factors and leakage factors were determined by the relation between chamber responses for irradiated and unirradiated cables. (author) [pt

  6. Holographic processing of track chamber data

    Energy Technology Data Exchange (ETDEWEB)

    Bykovsky, Y A; Larkin, A I; Markilov, A A; Starikov, S N [Moskovskij Fiziko-Tekhnicheskij Inst. (USSR)

    1975-12-01

    The holographic pattern recognition method was applied for processing of track chamber photographs. Experiments on detection of such events as a definitely directed track, an angle formed by two tracks, a three-pronged star, a definitely curved track were performed by using models. It is proposed to recognize these events in a filmshot by the shape of correlation signals. The experiment to recognize the event in a real bubble chamber filmshot was realized; requirements to the processing films were determined.

  7. Search for the best timing strategy in high-precision drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1983-06-01

    Computer simulated drift chamber pulses are used to investigate various possible timing strategies in the drift chambers. In particular, the leading edge, the multiple threshold and the flash ADC timing methods are compared. Although the presented method is general for any drift geometry, we concentrate our discussion on the jet chambers where the drift velocity is about 3 to 5 cm/μsec and the individual ionization clusters are not resolved due to a finite speed of our electronics

  8. The Antiproton Accumulator (AA)

    CERN Multimedia

    1980-01-01

    Section 06 - 08*) of the AA where the dispersion (and hence the horizontal beam size) is large. One can distinguish (left to right): A vacuum-tank, two bending magnets (BST06 and BST07 in blue) with a quadrupole (QDN07, in red) in between, another vacuum-tank, a wide quadrupole (QFW08) and a further tank . The tanks are covered with heating tape for bake-out. The tank left of BST06 contained the stack core pickup for stochastic cooling (see 7906193, 7906190, 8005051), the two other tanks served mainly as vacuum chambers in the region where the beam was large. Peter Zettwoch works on BST06. *) see: H. Koziol, Antiproton Accumulator Parameter List, PS/AA/Note 84-2 (1984)

  9. An MLC-based version for the ecliptic method for the determination of backscatter into the beam monitor chambers in photon beams of medical accelerators

    International Nuclear Information System (INIS)

    Nelli, Flavio Enrico

    2016-01-01

    A very simple method to measure the effect of the backscatter from secondary collimators into the beam monitor chambers in linear accelerators equipped with multi-leaf collimators (MLC) is presented here. The backscatter to the monitor chambers from the upper jaws of the secondary collimator was measured on three beam-matched linacs by means of three methods: this new methodology, the ecliptic method, and assessing the variation of the beam-on time per monitor unit with dose rate feedback disabled. This new methodology was used to assess the backscatter characteristics of asymmetric over-traveling jaws. Excellent agreement between the backscatter values measured using the new methodology introduced here and the ones obtained using the other two methods was established. The experimental values reported here differ by less than 1 % from published data. The sensitivity of this novel technique allowed differences in backscatter due to the same opening of the jaws, when placed at different positions on the beam path, to be resolved. The introduction of the ecliptic method has made the determination of the backscatter to the monitor chambers an easy procedure. The method presented here for machines equipped with MLCs makes the determination of backscatter to the beam monitor chambers even easier, and suitable to characterize linacs equipped with over-traveling asymmetric secondary collimators. This experimental procedure could be simply implemented to fully characterize the backscatter output factor constituent when detailed dosimetric modeling of the machine’s head is required. The methodology proved to be uncomplicated, accurate and suitable for clinical or experimental environments.

  10. Design and Construction of a Vertex Chamber and Measurement of the Average Beta-Hadron Lifetime

    Science.gov (United States)

    Nelson, Harry Norman

    Four parameters describe the mixing of the three quark generations in the Standard Model of the weak charged current interaction. These four parameters are experimental inputs to the model. A measurement of the mean lifetime of hadrons containing b-quarks, or B-Hadrons, constrains the magnitudes of two of these parameters. Measurement of the B-Hadron lifetime requires a device that can measure the locations of the stable particles that result from B-Hadron decay. This device must function reliably in an inaccessible location, and survive high radiation levels. We describe the design and construction of such a device, a gaseous drift chamber. Tubes of 6.9 mm diameter, having aluminized mylar walls of 100 μm thickness are utilized in this Vertex Chamber. It achieves a spatial resolution of 45 mum, and a resolution in extrapolation to the B-Hadron decay location of 87 mum. Its inner layer is 4.6 cm from e^+e ^- colliding beams. The Vertex Chamber is situated within the MAC detector at PEP. We have analyzed both the 94 pb ^{-1} of integrated luminosity accumulated at sqrt{s} = 29 GeV with the Vertex Chamber in place as well as the 210 pb^{-1} accumulated previously. We require a lepton with large momentum transverse to the event thrust axis to obtain a sample of events enriched in B-Hadron decays. The distribution of signed impact parameters of all tracks in these events is used to measure the B-Hadron flight distance, and hence lifetime. The trimmed mean signed impact parameters are 130 +/- 19 μm for data accumulated with the Vertex Chamber, and 162 +/- 25 μm for previous data. Together these indicate an average B-Hadron lifetime of tau_{b} = (1.37_sp{-0.19}{+0.22} stat. +/- 0.11 sys.) times (1 +/- 0.15 sys.) psec. We separate additive and multiplicative systematic errors because the second does not degrade the statistical significance of the difference of the result from 0. If b-c dominates b-quark decay the corresponding weak mixing matrix element mid V_ {cb

  11. Method and apparatus for active control of combustion rate through modulation of heat transfer from the combustion chamber wall

    Science.gov (United States)

    Roberts, Jr., Charles E.; Chadwell, Christopher J.

    2004-09-21

    The flame propagation rate resulting from a combustion event in the combustion chamber of an internal combustion engine is controlled by modulation of the heat transfer from the combustion flame to the combustion chamber walls. In one embodiment, heat transfer from the combustion flame to the combustion chamber walls is mechanically modulated by a movable member that is inserted into, or withdrawn from, the combustion chamber thereby changing the shape of the combustion chamber and the combustion chamber wall surface area. In another embodiment, heat transfer from the combustion flame to the combustion chamber walls is modulated by cooling the surface of a portion of the combustion chamber wall that is in close proximity to the area of the combustion chamber where flame speed control is desired.

  12. Dual ionization chamber

    International Nuclear Information System (INIS)

    Mallory, J.; Turlej, Z.

    1981-01-01

    Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source

  13. Upgrades Of The ATLAS Muon Spectrometer With sMDT Chambers

    CERN Document Server

    Ferretti, Claudio; The ATLAS collaboration

    2015-01-01

    The Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer demonstrated that they provide very precise and robust tracking over large areas. Goals of ATLAS muon detector upgrades are to increase the acceptance for precision muon momentum measurement and triggering and to improve the rate capability of the muon chambers in the high-background regions when the LHC luminosity increases. Small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages with the MDTs, but have more than ten times higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, reducing cost and construction time considerably and improving the sense wire positioning accuracy to better than ten microns. Two sMDT chambers have been installed in 2014 to improve the mom...

  14. National Dispute Resolution Chamber – Alternative Method of Conflict Resolution on Soccer

    Directory of Open Access Journals (Sweden)

    Amilar Fernandes Alves

    2016-12-01

    Full Text Available The soccer is still under studied and discussed in academic area, even though it has many mecanisms and singularities. One of the most recent mecanisms created is the National Dispute Resolution Chamber, sort of arbitration chamber created by CBF to solve all kind of conflicts. The NDRC has some particularities and conflicts with the national legal system, but it might be a faster and consensual way to solve the problems. Therefore we present the postive and negative points of the NDRC, make observations of its effects on the Justice and conclude indicating the posible alternatives.

  15. The KLOE drift chamber

    International Nuclear Information System (INIS)

    Ferrari, A.

    2002-01-01

    The design and construction of the large drift chamber of the KLOE experiment is presented. The track reconstruction is described, together with the calibration method and the monitoring systems. The stability of operation and the performance are studied with samples of e + e - , K S K L and K + K - events

  16. Search of significant features in a direct non parametric pattern recognition method. Application to the classification of a multiwire spark chamber picture

    International Nuclear Information System (INIS)

    Buccheri, R.; Coffaro, P.; Di Gesu, V.; Salemi, S.; Colomba, G.

    1975-01-01

    Preliminary results are given of the application of a direct non parametric pattern recognition method to the classification of the pictures of a multiwire spark chamber. The method, developed in an earlier work for an optical spark chamber, looks promising. The picture sample used has with respect to the previous one, the following characteristis: a) the event pictures have a more complicated structure; b) the amount of background sparks in an event is greater; c) there exists a kind of noise which is almost always present in some structured way (double sparkling, bursts...). New features have been used to characterize the event pictures; the results show that the method could be also used as a super filter to reduce the cost of further analysis. (Auth.)

  17. Structural stability analysis considerations in fusion reactor plasma chamber design

    International Nuclear Information System (INIS)

    Delaney, M.J.; Cramer, B.A.

    1978-01-01

    This paper presents an approach to analyzing a toroidal plasma chamber for the prevention of both static and dynamic buckling. Results of stability analyses performed for the doublet shaped plasma chamber of the General Atomic 3.8 meter radius TNS ignition test reactor are presented. Load conditions are the static external atmospheric pressure load and the dynamic plasma disruption pulse load. Methods for analysis of plasma chamber structures are presented for both types of load. Analysis for static buckling is based on idealizing the plasma chamber into standard structural shapes and applying classical cylinder and circular torus buckling equations. Results are verified using the Buckling of Shells of Revolution (BOSOR4) finite difference computer code. Analysis for the dynamic loading is based on a pulse buckling analysis method for circular cylinders

  18. Using activation method to measure neutron spectrum in an irradiation chamber of a research reactor

    International Nuclear Information System (INIS)

    Zhou Xuemei; Liu Guimin; Wang Xiaohe; Li Da; Meng Lingjie

    2014-01-01

    Neutron spectrum should be measured before test samples are irradiated. Neutron spectrum in an irradiation chamber of a research reactor was measured by using activation method when the reactor is in normal operation under 2 MW. Sixteen kinds of non-fission foils (19 reaction channels) were selected, of which 10 were sensitive to thermal and intermediate energy regions, while the others were of different threshold energy and sensitive to fast energy regions. By measuring the foil radioactivity, the neutron spectrum was unfolded with the iterative methods SAND-II and MSIT. Finally, shielding corrections of group cross-section and main factors affecting the calculation accuracy were studied and the uncertainty of solution was analyzed using the Monte Carlo method in the process of SAND-II. (authors)

  19. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Combustion instability control in the model of combustion chamber

    International Nuclear Information System (INIS)

    Akhmadullin, A N; Ahmethanov, E N; Iovleva, O V; Mitrofanov, G A

    2013-01-01

    An experimental study of the influence of external periodic perturbations on the instability of the combustion chamber in a pulsating combustion. As an external periodic disturbances were used sound waves emitted by the electrodynamics. The purpose of the study was to determine the possibility of using the method of external periodic perturbation to control the combustion instability. The study was conducted on a specially created model of the combustion chamber with a swirl burner in the frequency range from 100 to 1400 Hz. The study found that the method of external periodic perturbations may be used to control combustion instability. Depending on the frequency of the external periodic perturbation is observed as an increase and decrease in the amplitude of the oscillations in the combustion chamber. These effects are due to the mechanisms of synchronous and asynchronous action. External periodic disturbance generated in the path feeding the gaseous fuel, showing the high efficiency of the method of management in terms of energy costs. Power required to initiate periodic disturbances (50 W) is significantly smaller than the thermal capacity of the combustion chamber (100 kW)

  2. Track reconstruction in liquid hydrogen ionization chamber

    International Nuclear Information System (INIS)

    Balbekov, V.I.; Baranov, A.M.; Krasnokutski, R.N.; Perelygin, V.P.; Rasuvaev, E.A.; Shuvalov, R.S.; Zhigunov, V.P.; Lebedenko, V.N.; Stern, B.E.

    1979-01-01

    It is shown that particle track parameters can be reconstructed by the currents in the anode cells of the ionization chamber. The calculations are carried out for the chamber with 10 cm anode-cathode gap width. For simplicity a two-dimensional chamber model is used. To make the calculations simpler the charge density along the track is considered to be constant and equal to 10 4 electrons/mm. The drift velocity of electrons is assumed to be 5x10 6 cm/s. The anode is devided into cells 2 cm in width. The events in the chamber is defined with the coordinates X and Z of the event vertex, polar angles THETA of each track and track length l. The coordinates x, y and track angle THETA are reconstructed by currents with errors of up to millimetre and milliradian. The reconstruction errors are proportional to noise levels of electronics and also depend on the track geometry and argon purification. The energy resolution of the chamber is calculated for high energy electrons by means of computer program based on a Monter-Carlo method. The conclusion is made that the energy resolution depends on the gap width as a square root. Two ways to solve the track reconstruction problem are considered: 1. the initial charge density is determined by measuring the charges induced in anode strips at some discrete moments of time; 2. the evaluation of the parameters ia made by traditional minimization technique. The second method is applicable only for a not very large number of hypothesis, but it is less time consuming

  3. Development of a quality assured calibration method for the PSI radon chamber reference atmosphere

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.; Vezzu, G.

    1997-01-01

    Radon detectors and measuring instruments are calibrated at the PSI Reference Laboratory for Radon Gas Concentration Measurements by exposing them to a calibrated radon reference atmosphere in the PSI radon chamber. A sophisticated and quality assured calibration technique was developed which guarantees the traceability of this radon chamber reference atmosphere to standards of internationally acknowledged primary laboratories. (author) 2 figs., 2 refs

  4. An ionization chamber shower detector for the LHC luminosity monitor

    CERN Document Server

    Beche, J F; Datte, P S; Haguenauer, Maurice; Manfredi, P F; Millaud, J E; Placidi, Massimo; Ratti, L; Re, V; Riot, V J; Schmickler, Hermann; Speziali, V; Turner, W C

    2000-01-01

    The front IR quadrupole absorbers (TAS) and the IR neutral particle absorbers (TAN) in the high luminosity insertions of the Large Hadron Collider (LHC) each absorb approximately 1.8 TeV of forward collision products on average per pp interaction (~235 W at design luminosity 10/sup 34/ cm/sup -2/ s/sup -1/). This secondary particle flux can be exploited to provide a useful storage ring operations tool for optimization of luminosity. A novel segmented, multi-gap, pressurized gas ionization chamber is being developed for sampling the energy deposited near the maxima of the hadronic/electromagnetic showers in these absorbers. The system design choices have been strongly influenced by optimization of signal to noise ratio and by the very high radiation environment. The ionization chambers are instrumented with low noise, fast, pulse shaping electronics to be capable of resolving individual bunch crossings at 40 MHz. Data on each bunch are to be separately accumulated over multiple bunch crossings until the desire...

  5. Gas microstrip chambers

    International Nuclear Information System (INIS)

    McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.

    1992-01-01

    The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)

  6. Development and optimization of neutron measurement methods by fission chamber on experimental reactors - management, treatment and reduction of uncertainties

    International Nuclear Information System (INIS)

    Blanc-De-Lanaute, N.

    2012-01-01

    The main objectives of this research thesis are the management and reduction of uncertainties associated with measurements performed by means of a fission-chamber type sensor. The author first recalls the role of experimental reactors in nuclear research, presents the various sensors used in nuclear detection (photographic film, scintillation sensor, gas ionization sensor, semiconducting sensor, other types of radiation sensors), and more particularly addresses neutron detection (activation sensor, gas filling sensor). In a second part, the author gives an overview of the state of the art of neutron measurement by fission chamber in a mock-up reactor (signal formation, processing and post-processing, associated measurements and uncertainties, return on experience of measurements by fission chamber on Masurca and Minerve research reactors). In a third part, he reports the optimization of two intrinsic parameters of this sensor: the thickness of fissile material deposit, and the pressure and nature of the filler gas. The fourth part addresses the improvement of measurement electronics and of post-processing methods which are used for result analysis. The fifth part deals with the optimization of spectrum index measurements by means of a fission chamber. The impact of each parameter is quantified. Results explain some inconsistencies noticed in measurements performed on the Minerve reactor in 2004, and allow the improvement of biases with computed values [fr

  7. Double chamber ion source

    International Nuclear Information System (INIS)

    Uman, M.F.; Winnard, J.R.; Winters, H.F.

    1978-01-01

    The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)

  8. Ussing Chamber

    NARCIS (Netherlands)

    Westerhout, J.; Wortelboer, H.; Verhoeckx, K.

    2015-01-01

    The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are

  9. DELPHI Barrel Muon Chamber Module

    CERN Multimedia

    1989-01-01

    The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.

  10. Improvements in ionization chambers

    International Nuclear Information System (INIS)

    Whetten, N.R.; Zubal, C.

    1980-01-01

    A method of reducing mechanical vibrations transmitted to the parallel plate electrodes of ionization chamber x-ray detectors, commonly used in computerized x-ray axial tomography systems, is described. The metal plate cathodes and anodes are mounted in the ionizable gas on dielectric sheet insulators consisting of a composite of silicone resin and glass fibres. (UK)

  11. Gridded ionization chamber

    International Nuclear Information System (INIS)

    Houston, J.M.

    1977-01-01

    An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure

  12. Impact of beam transport method on chamber and driver design for heavy ion inertial fusion energy

    Energy Technology Data Exchange (ETDEWEB)

    Rose, D.V.; Welch, D.R.; Olson, C.L.; Yu, S.S.; Neff, S.; Sharp, W.M.

    2002-12-01

    In heavy ion inertial fusion energy systems, intense beams of ions must be transported from the exit of the final focus magnet system through the target chamber to hit millimeter spot sizes on the target. In this paper, we examine three different modes of beam propagation: neutralized ballistic transport, assisted pinched transport, and self-pinched transport. The status of our understanding of these three modes is summarized, and the constraints imposed by beam propagation upon the chamber environment, as well as their compatibility with various chamber and target concepts, are considered. We conclude that, on the basis of our present understanding, there is a reasonable range of parameter space where beams can propagate in thick-liquid wall, wetted-wall, and dry-wall chambers.

  13. Calibration of the central jet chamber of the OPAL detector with UV laser beams: Methods and results on jet chamber prototypes (FSP)

    International Nuclear Information System (INIS)

    Hauschild, M.

    1988-11-01

    The central tracking device of the OPAL experiment at the LEP e + e - -collider consists of a pictorial jet chamber with a diameter of 4 m and 4 m length. The calibration of such a large detector is performed by the help of a UV laser system generating straight tracks even in the presence of magnetic fields. Intensive investigations of the laser calibration power and performance were done at the Full Scale Prototype (FSP) of the OPAL jet chamber. Laser double tracks with a precisely known distance are used to determine the drift velocity with an accuracy of 0.1%. From the measured deviations of a straight laser track electronic time offsets, wire positions and field distortions are derived. These calibration constants were applied to correct the measured drift times of test beam events. The sagitta and momentum resolutions of the thus corrected tracks have been obtained in the range from 6 GeV/c to 50 GeV/c. Extrapolating the results to the final OPAL jet chamber, a momentum resolution of σ-p/p = 6% is expected for 50 GeV/c tracks in a magnetic field of 4 kG. (orig.) [de

  14. Design and construction of a vertex chamber and measurement of the average B-hadron lifetime

    International Nuclear Information System (INIS)

    Nelson, H.N.

    1988-01-01

    Four parameters describe the mixing of the three quark generations in the Standard Model of the weak charged current interaction. These four parameters are experimental inputs to the model. A measurement of the mean lifetime of hadrons containing b-quarks, or B-Hadrons, constrains the magnitudes of two of these parameters. Measurement of the B-Hadron lifetime require a device that can measure the locations of the stable particles that result from B-Hadron decay. This device must function reliably in an inaccessible location, and survive high radiation levels. We describe the design and construction of such a device, a gaseous drift chamber. Tubes of 6.9 mm diameter, having aluminized mylar walls of 100 μm thickness are utilized in this Vertex Chamber. It achieves a spatial resolution of 45 μm, and a resolution in extrapolation to the B-Hadron decay location of 87μm. Its inner layer is 4.6 cm from e +- colliding beams. The Vertex Chamber is situated within the MAC detector at PEP. We have analyzed both the 94 pb -1 of integrated luminosity accumulated at √s = 29 GeV with the Vertex Chamber in place as well as the 210 pb -1 accumulated previously. We require a lepton with large momentum transverse to the event thrust axis to obtain a sample of events enriched in B-Hadron decays. The distribution of signed impact parameters of all tracks in these events is used to measure the B-Hadron flight distance, and hence lifetime. If b-c dominates b-quark decay the corresponding weak mixing matrix element |V cb | = 0.47 ± 0.006 ± 0.005, where the first error is from this experiment, and the second theoretical uncertainty. If b-u dominates, |V ub | = 0.033 ± 0.004 ± 0.12

  15. The thin-wall tube drift chamber operating in vacuum (prototype)

    Science.gov (United States)

    Alexeev, G. D.; Glonti, L. N.; Kekelidze, V. D.; Malyshev, V. L.; Piskun, A. A.; Potrbenikov, Yu. K.; Rodionov, V. K.; Samsonov, V. A.; Tokmenin, V. V.; Shkarovskiy, S. N.

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. "Self-centering" spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  16. The thin-wall tube drift chamber operating in vacuum (prototype)

    International Nuclear Information System (INIS)

    Alexeev, G.D.; Glonti, L.N.; Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N.

    2013-01-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum

  17. The thin-wall tube drift chamber operating in vacuum (prototype)

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, G.D. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Glonti, L.N., E-mail: glonti@sunse.jinr.ru [Joint Institute for Nuclear Research, Dubna (Russian Federation); Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  18. A large volume striped bass egg incubation chamber: design and comparison with a traditional method

    Science.gov (United States)

    Harper, C.J.

    2009-01-01

    I conducted a comparative study of a new jar design (experimental chamber) with a standard egg incubation vessel (McDonald jar). Experimental chambers measured 0.4 m in diameter by 1.3 m in height and had a volume of 200 L. McDonald hatching jars measured 16 cm in diameter by 45 cm in height and had a volume of 6 L. Post-hatch survival was estimated at 48, 96 and 144 h. Stocking rates resulted in an average egg density of 21.9 eggs ml-1 (range = 21.6 – 22.1) for McDonald jars and 10.9 eggs ml-1 (range = 7.0 – 16.8) for experimental chambers. I was unable to detect an effect of container type on survival to 48, 96 or 144 h. At 144 h striped bass fry survival averaged 37.3% for McDonald jars and 34.2% for experimental chambers. Survival among replicates was significantly different. Survival of striped bass significantly decreased between 96 and 144 h. Mean survival among replicates ranged from 12.4 to 57.3%. I was unable to detect an effect of initial stocking density on survival. Experimental jars allow for incubation of a larger number of eggs in a much smaller space. As hatchery production is often limited by space or water supply, experimental chambers offer an alternative to extending spawning activities, thereby reducing manpower and cost. However, the increase in the number of eggs per rearing container does increase the risk associated with catastrophic loss of a production unit. I conclude the experimental chamber is suitable for striped bass egg incubation.

  19. Study on time response properties of ionization chamber in profile gauge

    International Nuclear Information System (INIS)

    Wang Zhentao; Shen Yixiong; Wang Liqiang; Hao Pengfei

    2011-01-01

    The drift time of ions in the ionization chamber was measured by means of using a shortly pulsed X-ray device and through analyzing the voltage signals on the load resistor of the chamber recorded by a digital oscilloscope. By using this method, the time response properties of the ionization chamber in the profile gauge were studied, results of ion drift time for ionization chambers with different internal structures, different voltages and different gas pressures were introduced and the sources of error were discussed. The experiment results show that the time response of ionization chamber in profile gauge meets the requirement of on-line hot strip measuring. (authors)

  20. Contributions to the methodology of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Petrascu, H.

    1993-01-01

    The Ph.D. thesis presents first the realization, testing, optimization, and use of detection equipment based on position sensitive multiwire proportional chambers (MWPC), high resolution proportional counters, and of ΔE,E ionization chambers. In the second chapter it is presented the realization MWPC, in which the coordinate information is obtained by means of LC-delay lines, containing many original constructive elements. By using a system of three MWPC in coincidence, an experimental testing of the theoretically predicted pion generation in the 235 U fission process, was performed. An upper limit of 10 -11 for this process was found. In the 3-rd chapter there are presented the developments of high resolution proportional counters for X-ray spectrometry. Various penning mixtures of high purity gases were studied. The purity of gases was assured by a technology described in a Romanian patents. These counters are currently use in various applications as a rapid analysis of steel marks and in the mining industry. the 4-th chapter is dedicated to the construction and using of ΔE,E closed, high resolution ionization chambers. With these chambers the multinucleon transfer in the 27 Al( 14 M, X) reaction at 116 MeV bombarding energy was investigated. Also this type of chambers was used for the elaboration of an absolute method for analysis and profiling of impurities in silicon wafers. This method is described in the last part of the chapter. (Author) 117 Figs., 8 Tabs., 55 Refs

  1. Radon chamber for soil gas detectors

    International Nuclear Information System (INIS)

    Andersson, P.

    1987-01-01

    Swedish Geological Co (SGAB) has designed and constructed a chamber for the calibration of detectors and instruments intended for the measurement of radon-222 in soil gas. In the chamber radon detectors may be exposed in a model environment which simulates ground conditions with respect to radon concentration, temperature and humidity. Also included in the research project is the development of methods for calibration procedures, together with test measurements. In general, these measurements indicate that the radon detectors tested are sufficiently accurate and reliable for radon measurements in Swedish soils if they are calibrated in an environment which simulates ground conditions. (orig./HP)

  2. A method for measuring the electron drift velocity in working gas using a Frisch-grid ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Huaiyong; Wang, Zhimin; Zhang, Luyu; Chen, Jinxiang; Zhang, Guohui, E-mail: guohuizhang@pku.edu.cn

    2016-12-21

    A method for measuring the electron drift velocity in working gas is proposed. Based on the cathode and the anode signal waveforms of the Frisch-grid ionization chamber, the electron drift velocity is extracted. With this method, the electron drift velocities in Ar + 10% CH{sub 4}, Ar + 3.5% CO{sub 2} and Kr + 2.7% CO{sub 2} gases have been measured and the results are compared with the existing measurements and the simulating results. Using this method, the electron drift velocity can be monitored throughout the experiment of charged particle without bothering the measurement of other parameters, such as the energy and orientation.

  3. Study of energy determination of gamma-ray observed with an emulsion chamber with a large gap

    International Nuclear Information System (INIS)

    Inui, Tamiki; Otsuka, Taeko; Masaoka, Akiko

    1982-01-01

    The development of large size emulsion chambers has been made to study very high energy events. For this purpose, the chambers with exchangeable light sensitive layers are considered. The chambers have large gap for the exchange. In this case, it becomes hard to determine the energy of cascade shower. In this report, the authors describe on the experimental examples observed at Mt. Chacaltaya. The effect of a gap was investigated by these examples, and the simulation method by Okamoto and Shibata was applied to the chamber. The chamber used for the observation consisted of the top chamber of 11 c.u. and the bottom chamber of 15 c.u. There was a large gap of 170 cm between two chambers. Twelve showers in three families observed by this system were analyzed. The difference between the blackness in the top and bottom films was studied quantitatively. The blackness was calibrated for the electron density. Four methods of energy determination were studied. Among them, a method to employ the sum of the maximum blackness of a top film and that of a bottom one was used for the analysis. This method seemed to be more reliable than the old method. It was found by a simulation calculation that the recovery of shower in the bottom chamber was seen not only by hardrons but also by gamma-ray. (Kato, T.)

  4. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    irradiator and at an industrial irradiation plant in static position, using different absorbing materials. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials. The uncertainties for all curves were less than 5%, which is recommended for a dosimetric system routine. The developed ionization chamber showed to be suitable as a dosimeter on line, independently of the spectrum degradation caused by the absorption of the 60 Co photons in the material under dynamic irradiation. (author)

  5. A test and calibration setup for mass-produced proportional chambers

    International Nuclear Information System (INIS)

    Burov, S.; Galaktionov, Yu.; Kamyshkov, Yu.

    1987-01-01

    The L3 experiment, presently being installed at (CERN) will use a 300 Hadron Calorimeter made of depleted uranium plates interleaved with about 8.000 proportional chambers. The review of experience in the use of gamma radioactivity of depleted uranium for the test of the chambers which are now being built at ITEP is given. The depleted uranium radioactivity and the response of a proportional chamber are discussed. A description of the test setup is given and a method to test the uniformity of the chamber response is discussed. Finally, a procedure for the L3 hadron calorimeter calibration in situ using uranium radioactivity is proposed

  6. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  7. Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications

    International Nuclear Information System (INIS)

    Zoetelief, J.; Broerse, J.J.

    1983-01-01

    The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation chamber employing a number of physical parameters. To arrive at the charge produced in the cavity several correction factors have to be introduced which are related to the operational characteristics of the chambers. Information on the operational characteristics of four TE ionisation chambers is presented in relation to ion collection, density and composition of gas in the cavity, wall thickness and effective point of measurement. In addition, some recent results from an ionisation chamber operated at high gas pressures are presented. The total absorbed doses derived from TE ionisation chambers show agreement within the uncertainty limits with results from other independent dosimetry methods, i.e., differential fluence measurements and a TE calorimeter. Conscientious experimentation and a common data base can provide dosimetry results with TE ionisation chambers with variations of less than +-2%. (author)

  8. Uranium deposits obtention for fission chambers

    International Nuclear Information System (INIS)

    Artacho Saviron, E.

    1972-01-01

    The obtention of uranium deposits of the required quality for small cylindrical fission chambers presents some difficulties. With the method of electroplating here described the uniformity, reproducibility and adherence of the obtained deposits were satisfactory. (Author) 6 refs

  9. A combination drift chamber/pad chamber for very high readout rates

    International Nuclear Information System (INIS)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W.; Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J.; Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S.; Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N.; Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T.; Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S.; Budagov, J.; Tsyganov, E.; Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N.; Chen, T.Y.; Yao, N.; Clark, K.; Jenkins, M.; Cooper, M.; Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Fortney, L.; Kowald, W.; Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D.; Lau, K.; Mo, G.; Trischuk, J.

    1991-11-01

    Six medium-sized (∼1 x 2 m 2 ) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers

  10. A combination drift chamber/pad chamber for very high readout rates

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. (Wisconsin Univ., Madison, WI (United States)); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. (Pavia Univ. (Italy) Istituto Nazionale di Fisica Nucleare, Rome (Italy)); Arenton, M.; Conetti, S.

    1991-11-01

    Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.

  11. PWCs and drift chambers at ISABELLE

    International Nuclear Information System (INIS)

    Okuno, H.; Teramoto, Y.; Wheeler, C.D.

    1979-01-01

    At the 1977 Workshop, attempts were made to predict the behavior of proportional wire chambers at the high particle flux expected at ISABELLE. It was found that chambers running at the now widely used high gas gain would have impaired performance with regard to lifetime, efficiency, stability of gas gain, and position resolution. More information has since become available, and therefore the predictions about these properties are revised in the present study. Improvement can also be expected with much lower gas gain, a possibility that is investigated here in more detail with regard to its effect on position resolution and time resolution. The expected high multiplicity of tracks from a single event, the high event rates, and the requirement for low gas gain necessitate revision of the methods for measuring the second coordinate. Particle identification via measurement of the relativistic rise of energy loss in the chambers has been investigated in more detail than previously, with new data and calculations

  12. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  13. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Some method of treating experimental data from X-ray chamber experiments

    International Nuclear Information System (INIS)

    Michalak, W.; Sroka, J.

    1977-01-01

    The procedure of studying the scaling law conservation using the cosmic radiation data from emulsion chambers is presented. The gamma-ray families are selected and processed in order to investigate the cascade development dependency on the primary particle energy. The most meaningful gamma family characteristics are proposed. (S.B.)

  15. A closed unventilated chamber for the measurement of transepidermal water loss.

    Science.gov (United States)

    Nuutinen, Jouni; Alanen, Esko; Autio, Pekka; Lahtinen, Marjo-Riitta; Harvima, Ilkka; Lahtinen, Tapani

    2003-05-01

    Open chamber systems for measuring transepidermal water loss (TEWL) have limitations related to ambient and body-induced airflows near the probe, probe size, measurement sites and angles, and measurement range. The aim of the present investigation was to develop a closed chamber system for the TEWL measurement without significant blocking of normal evaporation through the skin. Additionally, in order to use the evaporimeter to measure evaporation rates through other biological and non-biological specimens and in the field applications, a small portable, battery-operated device was a design criteria. A closed unventilated chamber (inner volume 2.0 cm(3) was constructed. For the skin measurement, the chamber with one side open (open surface area 1.0 cm(2) is placed on the skin. The skin application time was investigated at low and high evaporation rates in order to assess the blocking effect of the chamber on normal evaporation. From the rising linear part of the relative humidity (RH) in the chamber the slope was registered. The slope was calibrated into a TEWL value by evaporating water at different temperatures and measuring the water loss of heated samples with a laboratory scale. The closed chamber evaporation technique was compared with a conventional evaporimeter based on an open chamber method (DermaLab), Cortex Technology, Hadsund, Denmark). The reproducibility of the closed chamber method was measured with the water samples and with volar forearm and palm of the hand in 10 healthy volunteers. The skin application time varied between 7 and 9 s and the linear slope region between 3 and 5 s at the evaporation rates of 3-220 g/m(2) h. A correlation coefficient between the TEWL value from the closed chamber measurements and the readings of the laboratory scale was 0.99 (P measurements with the water samples was 4.0% at the evaporation rate of 40 g/m(2) h. A correlation coefficient of the TEWL values between the closed chamber and open chamber measurements was 0

  16. Numerical analysis of whole-body cryotherapy chamber design improvement

    Science.gov (United States)

    Yerezhep, D.; Tukmakova, A. S.; Fomin, V. E.; Masalimov, A.; Asach, A. V.; Novotelnova, A. V.; Baranov, A. Yu

    2018-05-01

    Whole body cryotherapy is a state-of-the-art method that uses cold for treatment and prevention of diseases. The process implies the impact of cryogenic gas on a human body that implements in a special cryochamber. The temperature field in the chamber is of great importance since local integument over-cooling may occur. Numerical simulation of WBC has been carried out. Chamber design modification has been proposed in order to increase the uniformity of the internal temperature field. The results have been compared with the ones obtained for a standard chamber design. The value of temperature gradient formed in the chamber containing curved wall with certain height has been decreased almost twice in comparison with the results obtained for the standard design. The modification proposed may increase both safety and comfort of cryotherapy.

  17. Processing methods for operation test data of radioactive aerosols monitor based on accumulation techniques

    International Nuclear Information System (INIS)

    Fu Cuiming; Xi Pingping; Ma Yinghao; Tan Linglong; Shen Fu

    2011-01-01

    This article introduces a radioactive aerosol continuous monitor based on accumulation sampling and measuring and three methods for processing the operation data. The monitoring results are processed by the 3 methods which are applied both under the conditions of natural background and at workplaces of a nuclear facility. How the monitoring results are assessed and how to calculate the detection limit when using the 3 different methods are explained. Moreover, the advantages and disadvantages of the 3 methods are discussed. (authors)

  18. Direct and simultaneous estimation of cardiac four chamber volumes by multioutput sparse regression.

    Science.gov (United States)

    Zhen, Xiantong; Zhang, Heye; Islam, Ali; Bhaduri, Mousumi; Chan, Ian; Li, Shuo

    2017-02-01

    Cardiac four-chamber volume estimation serves as a fundamental and crucial role in clinical quantitative analysis of whole heart functions. It is a challenging task due to the huge complexity of the four chambers including great appearance variations, huge shape deformation and interference between chambers. Direct estimation has recently emerged as an effective and convenient tool for cardiac ventricular volume estimation. However, existing direct estimation methods were specifically developed for one single ventricle, i.e., left ventricle (LV), or bi-ventricles; they can not be directly used for four chamber volume estimation due to the great combinatorial variability and highly complex anatomical interdependency of the four chambers. In this paper, we propose a new, general framework for direct and simultaneous four chamber volume estimation. We have addressed two key issues, i.e., cardiac image representation and simultaneous four chamber volume estimation, which enables accurate and efficient four-chamber volume estimation. We generate compact and discriminative image representations by supervised descriptor learning (SDL) which can remove irrelevant information and extract discriminative features. We propose direct and simultaneous four-chamber volume estimation by the multioutput sparse latent regression (MSLR), which enables jointly modeling nonlinear input-output relationships and capturing four-chamber interdependence. The proposed method is highly generalized, independent of imaging modalities, which provides a general regression framework that can be extensively used for clinical data prediction to achieve automated diagnosis. Experiments on both MR and CT images show that our method achieves high performance with a correlation coefficient of up to 0.921 with ground truth obtained manually by human experts, which is clinically significant and enables more accurate, convenient and comprehensive assessment of cardiac functions. Copyright © 2016 Elsevier

  19. Geological and taphonomic context for the new hominin species Homo naledi from the Dinaledi Chamber, South Africa

    Science.gov (United States)

    Dirks, Paul HGM; Berger, Lee R; Roberts, Eric M; Kramers, Jan D; Hawks, John; Randolph-Quinney, Patrick S; Elliott, Marina; Musiba, Charles M; Churchill, Steven E; de Ruiter, Darryl J; Schmid, Peter; Backwell, Lucinda R; Belyanin, Georgy A; Boshoff, Pedro; Hunter, K Lindsay; Feuerriegel, Elen M; Gurtov, Alia; Harrison, James du G; Hunter, Rick; Kruger, Ashley; Morris, Hannah; Makhubela, Tebogo V; Peixotto, Becca; Tucker, Steven

    2015-01-01

    We describe the physical context of the Dinaledi Chamber within the Rising Star cave, South Africa, which contains the fossils of Homo naledi. Approximately 1550 specimens of hominin remains have been recovered from at least 15 individuals, representing a small portion of the total fossil content. Macro-vertebrate fossils are exclusively H. naledi, and occur within clay-rich sediments derived from in situ weathering, and exogenous clay and silt, which entered the chamber through fractures that prevented passage of coarser-grained material. The chamber was always in the dark zone, and not accessible to non-hominins. Bone taphonomy indicates that hominin individuals reached the chamber complete, with disarticulation occurring during/after deposition. Hominins accumulated over time as older laminated mudstone units and sediment along the cave floor were eroded. Preliminary evidence is consistent with deliberate body disposal in a single location, by a hominin species other than Homo sapiens, at an as-yet unknown date. DOI: http://dx.doi.org/10.7554/eLife.09561.001 PMID:26354289

  20. Change of Pressing Chamber Conicalness at Briquetting Process in Briquetting Machine Pressing Chamber

    Directory of Open Access Journals (Sweden)

    Peter Križan

    2012-01-01

    Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.

  1. Effects of different mechanized soil fertilization methods on corn nutrient accumulation and yield

    Science.gov (United States)

    Shi, Qingwen; Bai, Chunming; Wang, Huixin; Wu, Di; Song, Qiaobo; Dong, Zengqi; Gao, Depeng; Dong, Qiping; Cheng, Xin; Zhang, Yahao; Mu, Jiahui; Chen, Qinghong; Liao, Wenqing; Qu, Tianru; Zhang, Chunling; Zhang, Xinyu; Liu, Yifei; Han, Xiaori

    2017-05-01

    Aim: Experiments for mechanized corn soil fertilization were conducted in Faku demonstration zone. On this basis, we studied effects on corn nutrient accumulation and yield traits at brown soil regions due to different mechanized soil fertilization measures. We also evaluated and optimized the regulation effects of mechanized soil fertilization for the purpose of crop yield increase and production efficiency improvement. Method: Based on the survey of soil background value in the demonstration zone, we collected plant samples during different corn growth periods to determine and make statistical analysis. Conclusions: Decomposed cow dung, when under mechanical broadcasting, was able to remarkably increase nitrogen and potassium accumulation content of corns at their ripe stage. Crushed stalk returning combined with deep tillage would remarkably increase phosphorus accumulation content of corn plants. When compared with top application, crushed stalk returning combined with deep tillage would remarkably increase corn thousand kernel weight (TKW). Mechanized broadcasting of granular organic fertilizer and crushed stalk returning combined with deep tillage, when compared with surface application, were able to boost corn yield in the in the demonstration zone.

  2. Multiwire proportional chamber development

    Science.gov (United States)

    Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.

    1973-01-01

    The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.

  3. The development and application of advanced analytical methods to commercial ICF reactor chambers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Cousseau, P.; Engelstad, R.; Henderson, D.L. [and others

    1997-10-01

    Progress is summarized in this report for each of the following tasks: (1) multi-dimensional radiation hydrodynamics computer code development; (2) 2D radiation-hydrodynamic code development; (3) ALARA: analytic and Laplacian adaptive radioactivity analysis -- a complete package for analysis of induced activation; (4) structural dynamics modeling of ICF reactor chambers; and (5) analysis of self-consistent target chamber clearing.

  4. The development and application of advanced analytical methods to commercial ICF reactor chambers. Final report

    International Nuclear Information System (INIS)

    Cousseau, P.; Engelstad, R.; Henderson, D.L.

    1997-10-01

    Progress is summarized in this report for each of the following tasks: (1) multi-dimensional radiation hydrodynamics computer code development; (2) 2D radiation-hydrodynamic code development; (3) ALARA: analytic and Laplacian adaptive radioactivity analysis -- a complete package for analysis of induced activation; (4) structural dynamics modeling of ICF reactor chambers; and (5) analysis of self-consistent target chamber clearing

  5. Transverse resistive wall instability of an off-axis ribbon beam in a circular chamber

    International Nuclear Information System (INIS)

    Courant, E.D.; Month, M.

    1978-06-01

    High energy proton storage rings are designed to make maximal use of the available vacuum chamber aperture. This is dictated primarily by economic considerations. The accumulation of current in a typical high energy ring creates a rather unusual beam configuration: in particular, a ribbon beam in a circular chamber set well off the central axis. The result is an enhanced resistive wall instability. This could be anticipated from the strong dependence of the current threshold on the chamber radius for a centered beam. For an off-centered beam, one might expect that the relevant replacement for the radius would be the distance of closest approach. The case of a wide ribbon-type beam is treated. The current threshold is obtained as a solution to a coupled oscillator eigenvalue problem. When the beam is small as occurs near the beginning of current stack formation, the problem is reduced to a dispersion relation. Results are expressed in terms of ISABELLE parameters. Some conclusions relevant to the ISABELLE design are presented

  6. Sleeve reaction chamber system

    Science.gov (United States)

    Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA

    2009-08-25

    A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.

  7. Dual-chamber inflatable oil boom

    International Nuclear Information System (INIS)

    Blair, R.M.; Tedeschi, E.T.

    1993-01-01

    An elongated floating material containment boom section is described having a normally vertical ballasted skirt depending from flotation means, and convertible from a flattened collapsed condition to a deployable condition wherein buoyancy chamber means extending along the upper edge of said skirt are inflated to expanded buoyant configuration, including: a gas-impervious sleeve extending along the upper edge of said normally vertical skirt forming a first outer collapsible and inflatable flotation chamber, a first inflation valve connecting the interior of said sleeve with the ambient atmosphere, through which gas under pressure may be introduced into said sleeve to inflate said first buoyant outer flotation chamber, elongated gas-impervious tube means positioned inside said outer flotation chamber and forming second collapsible and inflatable internal flotation bladder chamber means, second inflation valve means connecting the interior of said bladder means through said outer flotation chamber to the ambient atmosphere through which gas under pressure may be introduced into said bladder means to inflate it forming said second flotation chamber means inside said outer flotation chamber

  8. Testing an hydrogen streamer chamber

    CERN Multimedia

    1975-01-01

    A 2x10 cm gap streamer chamber, 35x55 cm2 in surface, was built and tested at CERN. Good tracks of cosmic rays were obtained up to atmospheric pressure, see F. Rohrbach et al, CERN-LAL (Orsay) Collaboration, Nucl. Instr. Methods 141 (1977) 229. Michel Cathenoz stand on the center.

  9. BEBC bubble chamber

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.

  10. Climatic chamber ergometer

    CSIR Research Space (South Africa)

    Atkins, AR

    1968-01-01

    Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...

  11. Depths of Magma Chambers in the Icelandic Crust

    Science.gov (United States)

    Kelley, D. F.; Kapostasy, D. D.; Barton, M.

    2004-05-01

    There is considerable interest in the structure and thermal state of the crust in Iceland, which lies across the Mid Atlantic Ridge. However, interpretations of seismic and gravity data yield conflicting views of the nature of the lower crust. Some interpretations prefer a model in which the lower crust (15-25 km) is relatively cool and solid, whereas other interpretations, based largely on gravity data, prefer a model in which the lower crust is relatively warm and possibly partially molten. Knowledge of the depth of magma chambers is critical to constrain the geothermal gradient in Icelandic crust and to resolve discrepancies in interpretation of geophysical data. Analyses of aphyric lavas and of glasses in Icelandic lavas erupted from 11 volcanic centers have been compiled. The compositions are picritic and basaltic with SiO2 - 47 to 50 wt%, MgO - 6 to 15wt%, FeO - 8 to 14wt%, to, Na2O - 1.3 to 3.3 wt%, and K2O - 0.03-46 wt%. The pressures of equilibration of these liquids with ol, high-Ca pyx and plag were estimated qualitatively from projections into the pseudoternary system Ol-Di-Silica using methods described by Walker and coworkers and Grove and coworkers. The results (ca. 0.5 GPa) indicate crystallization in magma chambers located at about 16 km depth. Equilibration pressures were also calculated using the method described by Yang and coworkers and by a modified version of this method. Calculated pressures (0.45±0.15 GPa) indicate magma chambers located at 15±4 km depth. Equilibration pressures for Rekjanes Ridge glasses determined using the same techniques are 0.2±0.1 GPa, corresponding to depths of 7.6±3 km. The results indicate the presence of magma chambers in the deep Icelandic crust and that the latter is relatively warm. Shallower chambers (3-7 km) have been identified from seismic studies suggesting a complex magma plumbing system. The results also confirm that magma chambers beneath Iceland are located at greater depths than those beneath the

  12. Vacuum Chambers for LEP sections

    CERN Multimedia

    1983-01-01

    The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.

  13. Comparison of the microdosimetric event-size method and the twin-chamber method of separating dose into neutron and gamma components

    International Nuclear Information System (INIS)

    Stinchcomb, T.G.; Kuchnir, F.T.; Skaggs, L.S.

    1980-01-01

    Microdosimetric measurements of event-size spectra, made with a proportional counter, are being used increasingly for separation of dose components in mixed n-γ fields. Measurements in fields produced by 8.3 MeV deuteron bombardment of thick beryllium and deuterium targets were made in air and at 6 and 12 cm depth in water with a spherical tissue-equivalent (TE) proportional counter and with a pair of calibrated ion chambers (TE-TE and Mg-Ar). The dose results obtained with the two methods agree well for the neutron components, but the gamma components do not demonstrate consistent agreement. An important source of error in the microdosimetric method is the matching of the spectra measured at different gain settings to cover the large range of event sizes. The effect of this and other sources of error is analysed. (author)

  14. Reference ionization chamber

    International Nuclear Information System (INIS)

    Golnik, N.; Zielczynski, M.

    1999-01-01

    The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)

  15. Bayesian inference method for stochastic damage accumulation modeling

    International Nuclear Information System (INIS)

    Jiang, Xiaomo; Yuan, Yong; Liu, Xian

    2013-01-01

    Damage accumulation based reliability model plays an increasingly important role in successful realization of condition based maintenance for complicated engineering systems. This paper developed a Bayesian framework to establish stochastic damage accumulation model from historical inspection data, considering data uncertainty. Proportional hazards modeling technique is developed to model the nonlinear effect of multiple influencing factors on system reliability. Different from other hazard modeling techniques such as normal linear regression model, the approach does not require any distribution assumption for the hazard model, and can be applied for a wide variety of distribution models. A Bayesian network is created to represent the nonlinear proportional hazards models and to estimate model parameters by Bayesian inference with Markov Chain Monte Carlo simulation. Both qualitative and quantitative approaches are developed to assess the validity of the established damage accumulation model. Anderson–Darling goodness-of-fit test is employed to perform the normality test, and Box–Cox transformation approach is utilized to convert the non-normality data into normal distribution for hypothesis testing in quantitative model validation. The methodology is illustrated with the seepage data collected from real-world subway tunnels.

  16. Operation method for wall surface of pressure suppression chamber of reactor container and floating scaffold used for the method

    International Nuclear Information System (INIS)

    Matsuzaki, Tetsuo; Kounomaru, Toshimi; Saito, Koichi.

    1996-01-01

    A floating scaffold is provisionally disposed in adjacent with the wall surface of pool water of a pressure suppression chamber while being floated on the surface of the pool water before the drainage of the pool water from the pressure vessel. The floating scaffold has guide rollers sandwiching a bent tube of an existent facility so that the horizontal movement is restrained, and is movable only in a vertical direction depending on the change of water level of the pool water. In addition, a handrail for preventing dropping, and a provisional illumination light are disposed. When pool water in the pressure suppression chamber is drained, the water level of the pool water is lowered in accordance with the amount of drained water. The floating scaffold floating on the water surface is lowered while being guided by the bent tube, and the operation position is lowered. An operator riding on the floating scaffold inspects the wall surfaces of the pressure chamber and conducts optional repair and painting. (I.N.)

  17. Application of a methane carbon isotope analyzer for the investigation of δ13C of methane emission measured by the automatic chamber method in an Arctic Tundra

    Science.gov (United States)

    Mastepanov, Mikhail; Christensen, Torben

    2014-05-01

    Methane emissions have been monitored by an automatic chamber method in Zackenberg valley, NE Greenland, since 2006 as a part of Greenland Ecosystem Monitoring (GEM) program. During most of the seasons the measurements were carried out from the time of snow melt (June-July) until freezing of the active layer (October-November). Several years of data, obtained by the same method, instrumentation and at exactly the same site, provided a unique opportunity for the analysis of interannual methane flux patterns and factors affecting their temporal variability. The start of the growing season emissions was found to be closely related to a date of snow melt at the site. Despite a large between year variability of this date (sometimes more than a month), methane emission started within a few days after, and was increasing for the next about 30 days. After this peak of emission, it slowly decreased and stayed more or less constant or slightly decreasing during the rest of the growing season (Mastepanov et al., Biogeosciences, 2013). During the soil freezing, a second peak of methane emission was found (Mastepanov et al., Nature, 2008); its amplitude varied a lot between the years, from almost undetectable to comparable with total growing season emissions. Analysis of the multiyear emission patterns (Mastepanov et al., Biogeosciences, 2013) led to hypotheses of different sources for the spring, summer and autumn methane emissions, and multiyear cycles of accumulation and release of these components to the atmosphere. For the further investigation of this it was decided to complement the monitoring system with a methane carbon isotope analyzer (Los Gatos Research, USA). The instrument was installed during 2013 field season and was successfully operating until the end of the measurement campaign (27 October). Detecting both 12C-CH4 and 13C-CH4 concentrations in real time (0.5 Hz) during automatic chamber closure (15 min), the instrument was providing data for determination of

  18. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  19. A comparison of different experimental methods for general recombination correction for liquid ionization chambers

    DEFF Research Database (Denmark)

    Andersson, Jonas; Kaiser, Franz-Joachim; Gomez, Faustino

    2012-01-01

    Radiation dosimetry of highly modulated dose distributions requires a detector with a high spatial resolution. Liquid filled ionization chambers (LICs) have the potential to become a valuable tool for the characterization of such radiation fields. However, the effect of an increased recombination...... of the charge carriers, as compared to using air as the sensitive medium has to be corrected for. Due to the presence of initial recombination in LICs, the correction for general recombination losses is more complicated than for air-filled ionization chambers. In the present work, recently published...

  20. Field controlled experiments of mercury accumulation in crops from air and soil

    Energy Technology Data Exchange (ETDEWEB)

    Niu Zhenchuan [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Zhang Xiaoshan, E-mail: zhangxsh@rcees.ac.cn [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Wang Zhangwei, E-mail: wangzhw@rcees.ac.cn [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Ci Zhijia [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)

    2011-10-15

    Field open top chambers (OTCs) and soil mercury (Hg) enriched experiments were employed to study the influence of Hg concentrations in air and soil on the Hg accumulation in the organs of maize (Zea mays L.) and wheat (Triticum aestivum L.). Results showed that Hg concentrations in foliages were correlated significantly (p < 0.05) with air Hg concentrations but insignificantly correlated with soil Hg concentrations, indicating that Hg in crop foliages was mainly from air. Hg concentrations in roots were generally correlated with soil Hg concentrations (p < 0.05) but insignificantly correlated with air Hg concentrations, indicating that Hg in crop roots was mainly from soil. No significant correlations were found between Hg concentrations in stems and those in air and soil. However, Hg concentrations in upper stems were usually higher than those in bottom stems, implying air Hg might have stronger influence than soil Hg on stem Hg accumulation. - Highlights: > Hg accumulation in crop organs was studied by OTCs and soil Hg enriched experiments. > Hg accumulation in foliages and roots was mainly from air and soil, respectively. > Air Hg had stronger influence than soil Hg on stem Hg accumulation. > Foliar Hg concentrations showed the trend of increase over growth stages. - Capsule Mercury accumulated in the aboveground organs of crop was mainly from the air.

  1. Prototype multiwire proportional chamber

    CERN Multimedia

    1975-01-01

    Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.

  2. Dispersed-fringe-accumulation-based left-subtract-right method for fine co-phasing of a dispersed fringe sensor.

    Science.gov (United States)

    Li, Yang; Wang, Shengqian; Rao, Changhui

    2017-05-20

    In this paper, a dispersed-fringe-accumulation (DFA)-based left-subtract-right (LSR) piston estimation method (DFA-LSR), in which the dispersed fringe image is accumulated in the dispersed direction, and then the LSR method is used to estimate the piston error, is proposed for dispersed fringe sensors (DFS) in the fine co-phasing stage. The DFS is usually used to detect the piston errors (optical path difference) between different segmented mirrors or synthetic aperture telescopes. The DFA-LSR makes up for the shortcomings of the main peak position (MPP) method, which suffers from the constant offset in the pixel counts. The analysis and experiment results show that the proposed method can keep relatively better performance even at the condition of poor signal-to-noise ratio, compared with the MPP method in fine co-phasing stage.

  3. Miniature ionization chamber

    International Nuclear Information System (INIS)

    Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.

    1976-01-01

    A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber

  4. Polarity effects and apparent ion recombination in microionization chambers

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Jessica R., E-mail: miller@humonc.wisc.edu [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Hooten, Brian D. [Standard Imaging, Middleton, Wisconsin 53562 (United States); Micka, John A.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2016-05-15

    Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered

  5. Novel method of charging an accumulator ring

    International Nuclear Information System (INIS)

    Maschke, A.W.

    1977-01-01

    For high power fusion applications, a circular accelerator for heavy ions is not likely to be competitive with a linear accelerator. This is principally because one requires rather high accelerator efficiencies, and quite large average power. Efficiencies greater than or equal to 10 percent, and perhaps 30 and 50 MW of average beam power are needed. On the other hand, the linear accelerator can be built to satisfy these constraints, and in addition, it is ideally suited for multi-turn injection. A difficulty with multi-turn injection is that in typical application it is rather lossy. With care, and sufficient phase space dilution, one might hope to obtain greater than or equal to 90 percent injection efficiency, but even at these levels the large amount of beam power lost in the accumulator might have serious consequences for the machine operation. Therefore, it is desirable to be able to use ''box car'' stacking, which is essentially 100 percent without particle loss. A method of operating the linear accelerator so that the output beam is of suitable instantaneous current to permit box-car stacking with the linac output is proposed

  6. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  7. Analysis method of intracellular iron accumulated in phytoplankton

    Directory of Open Access Journals (Sweden)

    Jorge Falcão Paredes

    1977-01-01

    Full Text Available A colorimetric method for the assessment of iron accumulated in the cells of phytoplankton utilizing potassium ferrocyanide was developed. Two experiences with Phaeodactylum tricornutum and Chlorella sp. were carried out: the first one, on uptake of the iron relatively to the age of the culture: the second one, on the iron uptake by the cells, relatively to different concentrations of the chelator EDTA.Foi desenvolvido um método para análise do ferro acumulado em células de fitoplâncton, usando ferrocianeto de potássio como agente complexante. Com esse objetivo montaram-se duas experiências: uma em que se mostra o acúmulo de ferro em relação à idade das células e uma segunda experiência onde a assimilação é plotada em função da concentração de EDTA no meio de cultura.

  8. A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2015-11-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOC) can be studied in detail. In PLUS all important enviromental parameters (e.g. temperature, PAR, soil RH etc.) are well-controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leafes of the plants is constructed such that gases are exposed to FEP Teflon film and other Teflon surfaces only to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 LED panels which have an emission strength up to 800 μmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOC) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light and temperature dependent BVOC emissions are studied using six Quercus Ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus Ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental set up and the utility of the newly added plant chamber.

  9. A new plant chamber facility, PLUS, coupled to the atmosphere simulation chamber SAPHIR

    Science.gov (United States)

    Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.

    2016-03-01

    A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been built and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow-through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees is mixed with synthetic air and transferred to the SAPHIR chamber, where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOCs) can be studied in detail. In PLUS all important environmental parameters (e.g., temperature, photosynthetically active radiation (PAR), soil relative humidity (RH)) are well controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leaves of the plants is constructed such that gases are exposed to only fluorinated ethylene propylene (FEP) Teflon film and other Teflon surfaces to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 light-emitting diode (LED) panels, which have an emission strength up to 800 µmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOCs) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light- and temperature- dependent BVOC emissions are studied using six Quercus ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental setup and the utility of the newly added plant chamber.

  10. Comparison of soil CO2 fluxes by eddy-covariance and chamber methods in fallow periods of a corn-soybean rotation

    Science.gov (United States)

    Soil carbon dioxide (CO2) fluxes are typically measured by eddy-covariance (EC) or chamber (Ch) methods, but a long-term comparison has not been undertaken. This study was conducted to assess the agreement between EC and Ch techniques when measuring CO2 flux during fallow periods of a corn-soybean r...

  11. Directed Energy Anechoic Chamber

    Data.gov (United States)

    Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...

  12. Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.

    2018-01-01

    Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

  13. Streamer chamber: pion decay

    CERN Multimedia

    1992-01-01

    The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.

  14. Accumulation Systems of Electric Energy Solved by Multicriteria Analysis Methods IPA and Topsis

    Directory of Open Access Journals (Sweden)

    Zdenek Hradilek

    2008-01-01

    Full Text Available This work deals with utilization of multicriteria analysis methods IPA and TOPSIS to assess three storage systems (Fuel Cells, Lead Acid Batteries and Pumped Storage Hydro Plants. Procedures of IPA and TOPSIS methods are described here as like as calculation of mentioned problem. Storage systems are assessed in terms of four criteria (Start up Time, Efficiency of Accumulation, Lifetime and Specific Costs/ kW of Power Output. Weights of criteria are also focused here. They are suggested by experts and statistically calculated.

  15. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  16. Directional muon jet chamber for a muon collider (Groovy Chamber)

    International Nuclear Information System (INIS)

    Atac, M.

    1996-10-01

    A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas

  17. Pencil-shaped radiation detection ionization chamber

    International Nuclear Information System (INIS)

    Suzuki, A.

    1979-01-01

    A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims

  18. In situ measurement of ceramic vacuum chamber conductive coating quality

    International Nuclear Information System (INIS)

    Doose, C.; Harkay, K.; Kim, S.; Milton, S.

    1997-01-01

    A method for measuring the relative surface resistivity and quality of conductive coatings on ceramic vacuum chambers was developed. This method is unique in that it allows one to test the coating even after the ceramic chamber is installed in the accelerator and under vacuum; furthermore, the measurement provides a localized surface reading of the coating conductance. The method uses a magnetic probe is calibrated using the measured DC end-to-end resistance of the tube under test and by comparison to a high quality test surface. The measurement method has also been verified by comparison to high frequency impedance measurements. A detailed description, results, and sensitivity of the technique are given here

  19. Improvement of Swirl Chamber Structure of Swirl-Chamber Diesel Engine Based on Flow Field Characteristics

    Directory of Open Access Journals (Sweden)

    Wenhua Yuan

    2014-10-01

    Full Text Available In order to improve combustion characteristic of swirl chamber diesel engine, a simulation model about a traditional cylindrical flat-bottom swirl chamber turbulent combustion diesel engine was established within the timeframe of the piston motion from the bottom dead centre (BDC to the top dead centre (TDC with the fluent dynamic mesh technique and flow field vector of gas in swirl chamber and cylinder; the pressure variation and temperature variation were obtained and a new type of swirl chamber structure was proposed. The results reveal that the piston will move from BDC; air in the cylinder is compressed into the swirl chamber by the piston to develop a swirl inside the chamber, with the ongoing of compression; the pressure and temperature are also rising gradually. Under this condition, the demand of diesel oil mixing and combusting will be better satisfied. Moreover, the new structure will no longer forma small fluid retention zone at the lower end outside the chamber and will be more beneficial to the mixing of fuel oil and air, which has presented a new idea and theoretical foundation for the design and optimization of swirl chamber structure and is thus of good significance of guiding in this regard.

  20. Hydraulic pitch control system for wind turbines: Advanced modeling and verification of an hydraulic accumulator

    DEFF Research Database (Denmark)

    Irizar, Victor; Andreasen, Casper Schousboe

    2017-01-01

    Hydraulic pitch systems provide robust and reliable control of power and speed of modern wind turbines. During emergency stops, where the pitch of the blades has to be taken to a full stop position to avoid over speed situations, hydraulic accumulators play a crucial role. Their efficiency...... and capability of providing enough energy to rotate the blades is affected by thermal processes due to the compression and decompression of the gas chamber. This paper presents an in depth study of the thermodynamical processes involved in an hydraulic accumulator during operation, and how they affect the energy...

  1. Establishment of a radon test chamber

    International Nuclear Information System (INIS)

    Chen Chingjiang; Liu Chichang; Lin Yuming

    1993-01-01

    A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)

  2. Corrective actions to gas accumulation in safety injection system pipings of PWRs and gas void detection method

    International Nuclear Information System (INIS)

    Maki, Nobuo

    2000-01-01

    In the US, gas accumulation events of safety injection systems of PWRs during plant operation are continuously reported. As the events may result in loss of safety function, the USNRC is alerting licensees by Information Notices. The cause of the events is coolant leakage to interfacing systems with lower pressure, or gas dissolution of primary coolant by partial pressure drop. In this study, it was clarified by the evaluation of the cause of the events of US plants, gas accumulation in piping between an accumulator and Residual Heat Removal System should be quantitatively investigated regarding Japanese plants. Also, effectiveness of ultrasonic testing which is used for monthly gas accumulation surveillance in US plants was demonstrated using a model loop. In addition, the method was confirmed applicable by an experiment carried out at INSS to detect cavitation voids in piping systems. (author)

  3. Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect

    Energy Technology Data Exchange (ETDEWEB)

    Barraclough, Brendan; Lebron, Sharon [Department of Radiation Oncology, University of Florida, Gainesville, Florida 32608 and J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Li, Jonathan G.; Fan, Qiyong; Liu, Chihray; Yan, Guanghua, E-mail: yangua@shands.ufl.edu [Department of Radiation Oncology, University of Florida, Gainesville, Florida 32608 (United States)

    2016-05-15

    Purpose: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). Methods: A convolution-based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit “real” ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber-measured profiles and the diode-measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%–80% penumbra width difference (PWD) between the computed and diode-measured beam profiles. Results: The convolution-based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependent DRFs, the PWD was within 0.80 mm for the parabolic function and CC04 combination and within 0.50 mm for other combinations; with geometry independent DRFs, the PWD was within 1.00 mm for all cases. When using the Gaussian function as the DRF, accounting for geometry dependence led to marginal improvement (PWD < 0.20 mm) for CC04; the improvement ranged from 0.38 to 0.65 mm for CC13; for SNC125c, the improvement was slightly above 0.50 mm. Conclusions: Although all three DRFs were found adequate to

  4. The Antiproton Accumulator (AA)

    CERN Multimedia

    1980-01-01

    A section of the AA where the dispersion (and hence the horizontal beam size) is large. One can distinguish (left to right): A large vacuum-tank, a quadrupole (QDN09*), a bending magnet (BST08), another vacuum-tank, a wide quadrupole (QFW08) and (in the background) a further bending magnet (BST08). The tanks are covered with heating tape for bake-out. The tank left of QDN09 contained the kickers for stochastic pre-cooling (see 790621, 8002234, 8002637X), the other one served mainly as vacuum chamber in the region where the beam was large. Peter Zettwoch works on QFW08. * see: H. Koziol, Antiproton Accumulator Parameter List, PS/AA/Note 84-2 (1984) See under 7911303, 7911597X, 8004261 and 8202324. For photos of the AA in different phases of completion (between 1979 and 1982) see: 7911303, 7911597X, 8004261, 8004608X, 8005563X, 8005565X, 8006716X, 8006722X, 8010939X, 8010941X, 8202324, 8202658X, 8203628X .

  5. Cloud Chamber

    DEFF Research Database (Denmark)

    Gfader, Verina

    Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...

  6. Construction and Test of New Precision Drift-Tube Chambers for the ATLAS Muon Spectrometer

    CERN Document Server

    INSPIRE-00218480

    2017-02-11

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 ?micons have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new R...

  7. Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices

    Directory of Open Access Journals (Sweden)

    Alberto Domínguez-Vicent

    2014-08-01

    Full Text Available Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D. Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera and the Pentacam HR (single Scheimpflug camera systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured with the Galilei G4 and the Pentacam HR, respectively. The mean white-to-white distance measured was 11.84 ± 0.31 mm and 11.90 ± 0.43 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Mean pupil diameters were measured as 3.22 ± 0.58 mm and 3.22 ± 0.52 mm when measured with the Galilei G4 and the Pentacam HR, respectively. Finally, the mean anterior chamber angle was 34.30 ± 2.86 degrees when it was measured with the Galilei G4, and 39.26 ± 2.85 degrees when measured with the Pentacam HR. A comparative analysis revealed that the Galilei G4 yielded a significantly lower (P0.05 for both devices were obtained for the white-to-white distance measurements. Conclusion: The Galilei G4 and Pentacam HR Scheimpflug systems cannot be used interchangeably because they produce significant measurement differences.

  8. Numerical Simulation of a Dual-Chamber Oscillating Water Column Wave Energy Converter

    Directory of Open Access Journals (Sweden)

    Dezhi Ning

    2017-09-01

    Full Text Available The performance of a dual-chamber Oscillating Water Column (OWC Wave Energy Converter (WEC is considered in the present study. The device has two sub-chambers with a shared orifice. A two-dimensional (2D fully nonlinear numerical wave flume based on the potential-flow theory and the time-domain higher-order boundary element method (HOBEM is applied for the simulation. The incident waves are generated by using the immerged sources and the air-fluid coupling influence is considered with a simplified pneumatic model. In the present study, the variation of the surface elevation and the water column volume in the two sub-chambers are investigated. The effects of the chamber geometry (i.e., the draft and breadth of two chambers on the surface elevation and the air pressure in the chamber are investigated, respectively. It is demonstrated that the surface elevations in the two sub-chambers are strongly dependent on the wave conditions. The larger the wavelength, the more synchronous motion of the two water columns in the two sub-chambers, thus, the lager the variation of the water column volume.

  9. Stability of fragrance patch test preparations applied in test chambers.

    Science.gov (United States)

    Mowitz, M; Zimerson, E; Svedman, C; Bruze, M

    2012-10-01

    Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  10. Field controlled experiments of mercury accumulation in crops from air and soil

    International Nuclear Information System (INIS)

    Niu Zhenchuan; Zhang Xiaoshan; Wang Zhangwei; Ci Zhijia

    2011-01-01

    Field open top chambers (OTCs) and soil mercury (Hg) enriched experiments were employed to study the influence of Hg concentrations in air and soil on the Hg accumulation in the organs of maize (Zea mays L.) and wheat (Triticum aestivum L.). Results showed that Hg concentrations in foliages were correlated significantly (p < 0.05) with air Hg concentrations but insignificantly correlated with soil Hg concentrations, indicating that Hg in crop foliages was mainly from air. Hg concentrations in roots were generally correlated with soil Hg concentrations (p < 0.05) but insignificantly correlated with air Hg concentrations, indicating that Hg in crop roots was mainly from soil. No significant correlations were found between Hg concentrations in stems and those in air and soil. However, Hg concentrations in upper stems were usually higher than those in bottom stems, implying air Hg might have stronger influence than soil Hg on stem Hg accumulation. - Highlights: → Hg accumulation in crop organs was studied by OTCs and soil Hg enriched experiments. → Hg accumulation in foliages and roots was mainly from air and soil, respectively. → Air Hg had stronger influence than soil Hg on stem Hg accumulation. → Foliar Hg concentrations showed the trend of increase over growth stages. - Capsule Mercury accumulated in the aboveground organs of crop was mainly from the air.

  11. Estimates of Two-Phase Flow Parameters in the Cyclone Chamber

    Directory of Open Access Journals (Sweden)

    Razva Aleksandr

    2016-01-01

    Full Text Available It provides analysis of methods for assessing circumferential speeds distribution of pressure in the cyclone chamber. It is shown that for cylindrical chambers of less than two diameters and the inlet section of at least 0.1 square cross section the maximum peripheral speed and rate distributions circumferential speeds along the current line is not changed. Analysis of the distribution shows that the concentration of small particles that are typical for gas dedusting systems have a significant impact on the distribution of pressure, vacuum and on the axis of the absolute value decreases toward dust of output section unlike the swirl chambers fuel combustion.

  12. Construction and test of new precision drift-tube chambers for the ATLAS muon spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Kroha, H., E-mail: kroha@mpp.mpg.de; Kortner, O.; Schmidt-Sommerfeld, K.; Takasugi, E.

    2017-02-11

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 μm have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

  13. Construction and test of new precision drift-tube chambers for the ATLAS muon spectrometer

    Science.gov (United States)

    Kroha, H.; Kortner, O.; Schmidt-Sommerfeld, K.; Takasugi, E.

    2017-02-01

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 μm have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

  14. Nova target chamber decontamination study

    International Nuclear Information System (INIS)

    1979-05-01

    An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report

  15. Comments on evaluation of energy of partial discharges in ionization chambers

    International Nuclear Information System (INIS)

    Lechowski, Z.

    1980-01-01

    A method of evaluation of energy of partial discharges in ionization chambers which are intended for investigation on electric strength of insulating materials is presented. It is demonstrated that an ionization chamber must be considered as a set of discharge sources and that for energy evaluation an amplitude analysis of apparent charge of discharges is useful. (author)

  16. Construction update and drift velocity calibration for the CLAS drift chamber system

    International Nuclear Information System (INIS)

    Mestayer, M.D.; Barbosa, F.J.; Bonneau, P.; Burtin, E.; Christo, S.; Doolittle, G.; Dytman, S.A.; Gilfoyle, G.P.; Hyde-Wright, C.E.; Klein, A.; Kossov, M.V.; Kuhn, S.E.; Magahiz, R.; Miskimen, R.A.; Murphy, L.Y.; O'Meara, J.E.; Pyron, T.D.; Qin, L.; Raue, B.A.; Schumacher, R.A.; Tuzel, W.; Weinstein, L.B.; Yegneswaran, A.

    1995-01-01

    We briefly describe the drift chamber system for the CLAS detector at CEBAF, concentrating on the method which will be used to calibrate the drift velocity function. We identify key features of the function which should apply to any small-cell drift chamber geometry in which the cathode and anode surfaces are wires. Using these ideas, we describe a simple method to compensate for variations in the drift velocity function due to environmental changes. (orig.)

  17. Construction update and drift velocity calibration for the CLAS drift chamber system

    Energy Technology Data Exchange (ETDEWEB)

    Mestayer, M.D. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Barbosa, F.J. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Bonneau, P. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Burtin, E. [University of South Carolina, Columbia, SC (United States); Christo, S. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Doolittle, G. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Dytman, S.A. [University of Pittsburg, Pittsburg, PA (United States); Gilfoyle, G.P. [University of Richmond, Richmond, VA (United States); Hyde-Wright, C.E. [Old Dominion University, Norfolk, VA (United States); Klein, A. [Old Dominion University, Norfolk, VA (United States); Kossov, M.V. [Christopher Newport University, Newport News, VA (United States); Kuhn, S.E. [Old Dominion University, Norfolk, VA (United States); Magahiz, R. [Carnegie-Mellon Univ., Pittsburgh, PA (United States); Miskimen, R.A. [University of Massachussetts, Amherst, MA (United States); Murphy, L.Y. [CE Saclay, Gif sur Yvette (France); O`Meara, J.E. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Pyron, T.D. [Old Dominion University, Norfolk, VA (United States); Qin, L. [Old Dominion University, Norfolk, VA (United States); Raue, B.A. [Old Dominion University, Norfolk, VA (United States); Schumacher, R.A. [Carnegie-Mellon Univ., Pittsburgh, PA (United States); Tuzel, W. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Weinstein, L.B. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States); Yegneswaran, A. [Continuous Electron Beam Accelerator Facility, Newport News, VA (United States)

    1995-12-11

    We briefly describe the drift chamber system for the CLAS detector at CEBAF, concentrating on the method which will be used to calibrate the drift velocity function. We identify key features of the function which should apply to any small-cell drift chamber geometry in which the cathode and anode surfaces are wires. Using these ideas, we describe a simple method to compensate for variations in the drift velocity function due to environmental changes. (orig.).

  18. The performance of low pressure tissue-equivalent chambers and a new method for parameterising the dose equivalent

    International Nuclear Information System (INIS)

    Eisen, Y.

    1986-01-01

    The performance of Rossi-type spherical tissue-equivalent chambers with equivalent diameters between 0.5 μm and 2 μm was tested experimentally using monoenergetic and polyenergetic neutron sources in the energy region of 10 keV to 14.5 MeV. In agreement with theoretical predictions both chambers failed to provide LET information at low neutron energies. A dose equivalent algorithm was derived that utilises the event distribution but does not attempt to correlate event size with LET. The algorithm was predicted theoretically and confirmed by experiment. The algorithm that was developed determines the neutron dose equivalent, from the data of the 0.5 μm chamber, to better than +-20% over the energy range of 30 keV to 14.5 MeV. The same algorithm also determines the dose equivalent from the data of the 2 μm chamber to better than +-20% over the energy range of 60 keV to 14.5 MeV. The efficiency of the chambers is 33 counts per μSv, or equivalently about 10 counts s -1 per mSv.h -1 . This efficiency enables the measurement of dose equivalent rates above 1 mSv.h -1 for an integration period of 3 s. Integrated dose equivalents can be measured as low as 1 μSv. (author)

  19. Dose rates from a C-14 source using extrapolation chamber and MC calculations

    International Nuclear Information System (INIS)

    Borg, J.

    1996-05-01

    The extrapolation chamber technique and the Monte Carlo (MC) calculation technique based on the EGS4 system have been studied for application for determination of dose rates in a low-energy β radiation field e.g., that from a 14 C source. The extrapolation chamber measurement method is the basic method for determination of dose rates in β radiation fields. Applying a number of correction factors and the stopping power ratio, tissue to air, the measured dose rate in an air volume surrounded by tissue equivalent material is converted into dose to tissue. Various details of the extrapolation chamber measurement method and evaluation procedure have been studied and further developed, and a complete procedure for the experimental determination of dose rates from a 14 C source is presented. A number of correction factors and other parameters used in the evaluation procedure for the measured data have been obtained by MC calculations. The whole extrapolation chamber measurement procedure was simulated using the MC method. The measured dose rates showed an increasing deviation from the MC calculated dose rates as the absorber thickness increased. This indicates that the EGS4 code may have some limitations for transport of very low-energy electrons. i.e., electrons with estimated energies less than 10 - 20 keV. MC calculations of dose to tissue were performed using two models: a cylindrical tissue phantom and a computer model of the extrapolation chamber. The dose to tissue in the extrapolation chamber model showed an additional buildup dose compared to the dose in the tissue model. (au) 10 tabs., 11 ills., 18 refs

  20. Development of Aluminium Vacuum Chambers for the LHC Experiments at CERN

    CERN Document Server

    Gallilee, M; Costa-Pinto, P; Lepeule, P; Perez-Espinos, J; Marques Antunes Ferreira, L; Prever-Loiri, L; Sapountzis, A

    2014-01-01

    Beam losses may cause activation of vacuum chamber walls, in particular those of the Large Hadron Collider (LHC) experiments. For the High Luminosity (HL-LHC), the activation of such vacuum chambers will increase. It is therefore necessary to use a vacuum chamber material which interacts less with the circulating beam. While beryllium is reserved for the collision point, a good compromise between cost, availability and transparency is obtained with aluminium alloys; such materials are a preferred choice with respect to austenitic stainless steel. Manufacturing a thin-wall aluminium vacuum chamber presents several challenges as the material grade needs to be machinable, weldable, leak-tight for small thicknesses, and able to withstand heating to 250°C for extended periods of time. This paper presents some of the technical challenges during the manufacture of these vacuum chambers and the methods for overcoming production difficulties, including surface treatments and Non-Evaporable Getter (NEG) thin-film coat...

  1. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Earthworms accumulate alanine in response to drought.

    Science.gov (United States)

    Holmstrup, Martin; Slotsbo, Stine; Henriksen, Per G; Bayley, Mark

    2016-09-01

    Earthworms have ecologically significant functions in tropical and temperate ecosystems and it is therefore important to understand how these animals survive during drought. In order to explore the physiological responses to dry conditions, we simulated a natural drought incident in a laboratory trial exposing worms in slowly drying soil for about one month, and then analyzed the whole-body contents of free amino acids (FAAs). We investigated three species forming estivation chambers when soils dry out (Aporrectodea tuberculata, Aporrectodea icterica and Aporrectodea longa) and one species that does not estivate during drought (Lumbricus rubellus). Worms subjected to drought conditions (alanine that was significantly upregulated in all tested species. Alanine was the most important FAA reaching 250-650μmolg(-1) dry weight in dehydrated Aporrectodea species and 300μmolg(-1) dry weight in L. rubellus. Proline was only weakly upregulated in some species as were a few other FAAs. Species forming estivation chambers (Aporrectodea spp.) did not show a better ability to conserve body water than the non-estivating species (L. rubellus) at the same drought level. These results suggest that the accumulation of alanine is an important adaptive trait in drought tolerance of earthworms in general. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Reasonable selection of automatic exposure density compensation of ionization chamber

    International Nuclear Information System (INIS)

    Tian Fuqiang; Nie Shikun; Wang Zhihong; Zeng Jianhua; Cheng Guanxun; Xiang Qian

    2000-01-01

    Objective: To introduce and discuss the methods of reasonable selection of the automatic exposure density compensation of ionization chamber to provide important references for clinic radiograph and improve the quality of images. Methods: X-ray machines with ionization chamber automatic exposure control system were used in this study. Compared with the standard baseline of the normal density of the object radio-graphed, the reasonable ionization chamber density compensation (IDC) was chosen and compared with the radiograph without IDC through a water model test and density measurement. Results: There was no significant difference between two groups (100 films each) which were randomly divided to the group with or without IDC, but there was statistically significant difference in the special groups. Conclusion: To select suitable IDC is very important for guaranteeing radiographic quality, moreover, to establish a suitable kV is also necessary, usually it is 10 to 20 kV higher than the optioned kV. The relative factors must be fixed relatively and be matched correctly

  6. Criteria for controlled atmosphere chambers

    International Nuclear Information System (INIS)

    Robinson, J.N.

    1980-03-01

    The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices

  7. Simulation of pore pressure accumulation under cyclic loading using Finite Volume Method

    DEFF Research Database (Denmark)

    Tang, Tian; Hededal, Ole

    2014-01-01

    This paper presents a finite volume implementation of a porous, nonlinear soil model capable of simulating pore pressure accumulation under cyclic loading. The mathematical formulations are based on modified Biot’s coupled theory by substituting the original elastic constitutive model...... with an advanced elastoplastic model suitable for describing monotonic as well as cyclic loading conditions. The finite volume method is applied to discretize these formulations. The resulting set of coupled nonlinear algebraic equations are then solved by a ’segregated’ solution procedure. An efficient return...

  8. Technical note: drifting versus anchored flux chambers for measuring greenhouse gas emissions from running waters

    Science.gov (United States)

    Lorke, A.; Bodmer, P.; Noss, C.; Alshboul, Z.; Koschorreck, M.; Somlai-Haase, C.; Bastviken, D.; Flury, S.; McGinnis, D. F.; Maeck, A.; Müller, D.; Premke, K.

    2015-12-01

    Stream networks have recently been discovered to be major but poorly constrained natural greenhouse gas (GHG) sources. A fundamental problem is that several measurement approaches have been used without cross-comparisons. Flux chambers represent a potentially powerful methodological approach if robust and reliable ways to use chambers on running water can be defined. Here we compare the use of anchored and freely drifting chambers on various streams with different flow velocities. The study clearly shows that (1) anchored chambers enhance turbulence under the chambers and thus elevate fluxes, (2) drifting chambers have a very small impact on the water turbulence under the chamber and thus generate more reliable fluxes, (3) the bias of the anchored chambers greatly depends on chamber design and sampling conditions, and (4) there is a promising method to reduce the bias from anchored chambers by using a flexible plastic foil collar to seal the chambers to the water surface, rather than having rigid chamber walls penetrating into the water. Altogether, these results provide novel guidance on how to apply flux chambers in running water, which will have important consequences for measurements to constrain the global GHG balances.

  9. Development of special ionization chambers for a quality control program in mammography

    International Nuclear Information System (INIS)

    Silva, Jonas Oliveira da

    2013-01-01

    Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)

  10. Proceedings of workshop on streamer chamber

    International Nuclear Information System (INIS)

    Itoh, Hidihiko; Takahashi, Kaoru; Hirose, Tachishige; Masaike, Akira

    1978-08-01

    For high accuracy observation of multiple-body reactions, a vertex detector of high efficiency is essential. A bubble chamber, though excellent for tracks detection, is problematic in statistics accuracy. The vertex detector with a wire chamber, while better in this respect, difficult in multiple-particle detection etc. The workshop has had several meetings on a streamer chamber as a detector combining features of both bubble chamber and counter, with emphasis on tracks observation in avalanche mode and recordings not using films. Contents are on streamer chamber gas, analytical photography, data processing, simulation program, etc. (Mori, K.)

  11. Gridded Ionization Chamber

    International Nuclear Information System (INIS)

    Manero Amoros, F.

    1962-01-01

    In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs

  12. Estimation of nocturnal CO2 and N2O soil emissions from changes in surface boundary layer mass storage

    Science.gov (United States)

    Grant, Richard H.; Omonode, Rex A.

    2018-04-01

    Annual budgets of greenhouse and other trace gases require knowledge of the emissions throughout the year. Unfortunately, emissions into the surface boundary layer during stable, calm nocturnal periods are not measurable using most micrometeorological methods due to non-stationarity and uncoupled flow. However, during nocturnal periods with very light winds, carbon dioxide (CO2) and nitrous oxide (N2O) frequently accumulate near the surface and this mass accumulation can be used to determine emissions. Gas concentrations were measured at four heights (one within and three above canopy) and turbulence was measured at three heights above a mature 2.5 m maize canopy from 23 July to 10 September 2015. Nocturnal CO2 and N2O fluxes from the canopy were determined using the accumulation of mass within a 6.3 m control volume and out the top of the control volume within the nocturnal surface boundary layer. Diffusive fluxes were estimated by flux gradient method. The total accumulative and diffusive fluxes during near-calm nights (friction velocities CO2 and 0.53 nmol m-2 s-1 N2O. Fluxes were also measured using chambers. Daily mean CO2 fluxes determined by the accumulation method were 90 to 130 % of those determined using soil chambers. Daily mean N2O fluxes determined by the accumulation method were 60 to 80 % of that determined using soil chambers. The better signal-to-noise ratios of the chamber method for CO2 over N2O, non-stationary flow, assumed Schmidt numbers, and anemometer tilt were likely contributing reasons for the differences in chambers versus accumulated nocturnal mass flux estimates. Near-surface N2O accumulative flux measurements in more homogeneous regions and with greater depth are needed to confirm the conclusion that mass accumulation can be effectively used to estimate soil emissions during nearly calm nights.

  13. The CLEO III drift chamber

    CERN Document Server

    Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D

    2002-01-01

    The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).

  14. Density and impurity profile behaviours in HL-2A tokamak with different gas fuelling methods

    International Nuclear Information System (INIS)

    Zheng-Ying, Cui; Yan, Zhou; Wei, Li; Bei-Bin, Feng; Ping, Sun; Chun-Feng, Dong; Yi, Liu; Wen-Yu, Hong; Qing-Wei, Yang; Xuan-Tong, Ding; Xu-Ru, Duan

    2009-01-01

    The electron density profile peaking and the impurity accumulation in the HL-2A tokamak plasma are observed when three kinds of fuelling methods are separately used at different fuelling particle locations. The density profile becomes more peaked when the line-averaged electron density approaches the Greenwald density limit n G and, consequently, impurity accumulation is often observed. A linear increase regime in the density range n e G and a saturation regime in n e > 0.6n G are obtained. There is no significant difference in achieved density peaking factor f ne between the supersonic molecular beam injection (SMBI) and gas puffing into the plasma main chamber. However, the achieved f ne is relatively low, in particular, in the case of density below 0.7n G , when the working gas is puffed into the divertor chamber. A discharge with a density as high as 1.2n G , i.e. n e = 1.2n G , can be achieved by SMBI just after siliconization as a wall conditioning. The metallic impurities, such as iron and chromium, also increase remarkably when the impurity accumulation happens. The mechanism behind the density peaking and impurity accumulation is studied by investigating both the density peaking factor versus the effective collisionality and the radiation peaking versus density peaking. (fluids, plasmas and electric discharges)

  15. Validation of odor concentration from mechanical-biological treatment piles using static chamber and wind tunnel with different wind speed values.

    Science.gov (United States)

    Szyłak-Szydłowski, Mirosław

    2017-09-01

    The basic principle of odor sampling from surface sources is based primarily on the amount of air obtained from a specific area of the ground, which acts as a source of malodorous compounds. Wind tunnels and flux chambers are often the only available, direct method of evaluating the odor fluxes from small area sources. There are currently no widely accepted chamber-based methods; thus, there is still a need for standardization of these methods to ensure accuracy and comparability. Previous research has established that there is a significant difference between the odor concentration values obtained using the Lindvall chamber and those obtained by a dynamic flow chamber. Thus, the present study compares sampling methods using a streaming chamber modeled on the Lindvall cover (using different wind speeds), a static chamber, and a direct sampling method without any screens. The volumes of chambers in the current work were similar, ~0.08 m 3 . This study was conducted at the mechanical-biological treatment plant in Poland. Samples were taken from a pile covered by the membrane. Measured odor concentration values were between 2 and 150 ou E /m 3 . Results of the study demonstrated that both chambers can be used interchangeably in the following conditions: odor concentration is below 60 ou E /m 3 , wind speed inside the Lindvall chamber is below 0.2 m/sec, and a flow value is below 0.011 m 3 /sec. Increasing the wind speed above the aforementioned value results in significant differences in the results obtained between those methods. In all experiments, the results of the concentration of odor in the samples using the static chamber were consistently higher than those from the samples measured in the Lindvall chamber. Lastly, the results of experiments were employed to determine a model function of the relationship between wind speed and odor concentration values. Several researchers wrote that there are no widely accepted chamber-based methods. Also, there is still a

  16. A comparison of methane emission measurements using eddy covariance and manual and automated chamber-based techniques in Tibetan Plateau alpine wetland

    International Nuclear Information System (INIS)

    Yu, Lingfei; Wang, Hao; Wang, Guangshuai; Song, Weimin; Huang, Yao; Li, Sheng-Gong; Liang, Naishen; Tang, Yanhong; He, Jin-Sheng

    2013-01-01

    Comparing of different CH 4 flux measurement techniques allows for the independent evaluation of the performance and reliability of those techniques. We compared three approaches, the traditional discrete Manual Static Chamber (MSC), Continuous Automated Chamber (CAC) and Eddy Covariance (EC) methods of measuring the CH 4 fluxes in an alpine wetland. We found a good agreement among the three methods in the seasonal CH 4 flux patterns, but the diurnal patterns from both the CAC and EC methods differed. While the diurnal CH 4 flux variation from the CAC method was positively correlated with the soil temperature, the diurnal variation from the EC method was closely correlated with the solar radiation and net CO 2 fluxes during the daytime but was correlated with the soil temperature at nighttime. The MSC method showed 25.3% and 7.6% greater CH 4 fluxes than the CAC and EC methods when measured between 09:00 h and 12:00 h, respectively. -- Highlights: •Chamber and eddy covariance methods showed similar seasonal CH 4 flux patterns. •Chamber and eddy covariance methods showed different diurnal CH 4 flux patterns. •Static chamber methods gave a higher magnitude of CH 4 flux. -- The chamber-based methods and the eddy covariance method showed similar seasonal CH 4 flux patterns, but the manual static chamber method resulted in a higher CH 4 flux measurement

  17. Small-Chamber Measurements of Chemical-Specific Emission Factors for Drywall

    Energy Technology Data Exchange (ETDEWEB)

    Maddalena, Randy; Russell, Marion; Apte, Michael G.

    2010-06-01

    Imported drywall installed in U.S. homes is suspected of being a source of odorous and potentially corrosive indoor pollutants. To support an investigation of those building materials by the Consumer Products Safety Commission (CPSC), Lawrence Berkeley National Laboratory (LBNL) measured chemical-specific emission factors for 30 samples of drywall materials. Emission factors are reported for 75 chemicals and 30 different drywall samples encompassing both domestic and imported stock and incorporating natural, synthetic, or mixed gypsum core material. CPSC supplied all drywall materials. First the drywall samples were isolated and conditioned in dedicated chambers, then they were transferred to small chambers where emission testing was performed. Four sampling and analysis methods were utilized to assess (1) volatile organic compounds, (2) low molecular weight carbonyls, (3) volatile sulfur compounds, and (4) reactive sulfur gases. LBNL developed a new method that combines the use of solid phase microextraction (SPME) with small emission chambers to measure the reactive sulfur gases, then extended that technique to measure the full suite of volatile sulfur compounds. The testing procedure and analysis methods are described in detail herein. Emission factors were measured under a single set of controlled environmental conditions. The results are compared graphically for each method and in detailed tables for use in estimating indoor exposure concentrations.

  18. OPAL Jet Chamber Prototype

    CERN Multimedia

    OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers

  19. Development of secondary chamber for tar cracking-improvement of wood pyrolysis performance in pre-vacuum chamber

    Science.gov (United States)

    Siahaan, S.; Homma, H.; Homma, H.

    2018-02-01

    Energy crisis and global warming, in other words, climate change are critical topics discussed in various parts of the world. Global warming primarily result from too much emission of carbon dioxide (CO2) in the atmosphere. To mitigate global warming, or climate change and improve electrification in rural areas, wood pyrolysis technology is developed in a laboratory scale, of which gases are directly applicable to the gas engine generator. Our laboratory has developed a prototype of wood pyrolysis plant with a pre-vacuum chamber. However, tar yield was around 40 wt% of feedstock. This research aims to reduce tar yield by secondary tar cracking. For the secondary tar cracking, a secondary pre-vacuum chamber is installed after primary pre-vacuum chamber. Gases generated in the primary pre-vacuum chamber are lead into the secondary chamber that is heated up to 1000 K. This paper reports performance of the secondary chamber for secondary tar cracking in homogeneous mode and heterogeneous mode with char.

  20. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    Science.gov (United States)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the

  1. Results from the calibration of Z chambers with cosmic muons

    International Nuclear Information System (INIS)

    Alcaraz, J.; Cerrada, M.; Gonzalez, E.

    1992-01-01

    We describe a cosmic ray calibration procedure applied to L3 Z muon chambers. The experimental set up, and the method of data analysis used, are presented. We show the results obtained with different gas mixtures. The effect of variations in the values of some parameters, like the discriminator thresholds or the sense wire high voltages, on the chamber resolution and on the track reconstruction efficiency, is also reported. (author) 18 fig. 8 ref

  2. Experimental and calculated calibration of ionization chambers with air circulation

    CERN Document Server

    Peetermans, A

    1972-01-01

    The reports describes the method followed in order to calibrate the different ionization chambers with air circulation, used by the 'Health Physics Group'. The calculations agree more precisely with isotopes cited previously (/sup 11/C, /sup 13/N, /sup 15/O, /sup 41 /Ar, /sup 14/O, /sup 38/Cl) as well as for /sup 85/Kr, /sup 133/Xe, /sup 14/C and tritium which are used for the experimental standardisation of different chambers.

  3. A new mini-extrapolation chamber for beta source uniformity measurements

    International Nuclear Information System (INIS)

    Oliveira, M.L.; Caldas, L.V.E.

    2006-01-01

    According to recent international recommendations, beta particle sources should be specified in terms of absorbed dose rates to water at the reference point. However, because of the clinical use of these sources, additional information should be supplied in the calibration reports. This additional information include the source uniformity. A new small volume extrapolation chamber was designed and constructed at the Calibration Laboratory at Instituto de Pesquisas Energeticas e Nucleares, IPEN, Brazil, for the calibration of 90 Sr+ 90 Y ophthalmic plaques. This chamber can be used as a primary standard for the calibration of this type of source. Recent additional studies showed the feasibility of the utilization of this chamber to perform source uniformity measurements. Because of the small effective electrode area, it is possible to perform independent measurements by varying the chamber position by small steps. The aim of the present work was to study the uniformity of a 90 Sr+ 90 Y plane ophthalmic plaque utilizing the mini extrapolation chamber developed at IPEN. The uniformity measurements were performed by varying the chamber position by steps of 2 mm in the source central axis (x-and y-directions) and by varying the chamber position off-axis by 3 mm steps. The results obtained showed that this small volume chamber can be used for this purpose with a great advantage: it is a direct method, being unnecessary a previously calibration of the measurement device in relation to a reference instrument, and it provides real -time results, reducing the time necessary for the study and the determination of the uncertainties related to the measurements. (authors)

  4. Proportional chamber with data analog output

    International Nuclear Information System (INIS)

    Popov, V.E.; Prokof'ev, A.N.

    1977-01-01

    A proportional multiwier chamber is described. The chamber makes it possible to determine angles at wich a pion strikes a polarized target. A delay line, made of 60-core flat cable is used for removing signals from the chamber. From the delay line, signals are amplified and successively injected into shapers and a time-to-amplitude converter. An amplitude of the time-to amplitude converter output signal unambiguously determines the coordinate of a point at which a particle strikes the chamber plane. There are also given circuits of amplifiers, which consist of a preamplifier with gain 30 and a main amplifier with adjustable gain. Data on testing the chamber with the 450 MeV pion beam is demonstrated. The chamber features an efficiency of about 98 per cent under load of 2x10 5 s -1

  5. Technical Note: Drifting vs. anchored flux chambers for measuring greenhouse gas emissions from running waters

    Science.gov (United States)

    Lorke, A.; Bodmer, P.; Noss, C.; Alshboul, Z.; Koschorreck, M.; Somlai, C.; Bastviken, D.; Flury, S.; McGinnis, D. F.; Maeck, A.; Müller, D.; Premke, K.

    2015-09-01

    Stream networks were recently discovered as major but poorly constrained natural greenhouse gas (GHG) sources. A fundamental problem is that several measurement approaches have been used without cross comparisons. Flux chambers represent a potentially powerful methodological approach if robust and reliable ways to use chambers on running water can be defined. Here we compare the use of anchored and freely drifting chambers on various streams having different flow velocities. The study clearly shows that (1) drifting chambers have a very small impact on the water turbulence under the chamber and thus generate more reliable fluxes, (2) anchored chambers enhance turbulence under the chambers and thus elevate fluxes, (3) the bias of the anchored chambers greatly depends on chamber design and sampling conditions, and (4) there is a promising method to reduce the bias from anchored chambers by using a flexible plastic foil seal to the water surface rather than having rigid chamber walls penetrating into the water. Altogether, these results provide novel guidance on how to apply flux chambers in running water, which will have important consequences for measurements to constrain the global GHG balances.

  6. A chromatographic method to analyze products from photo-oxidation of anthropogenic and biogenic mixtures of volatile organic compounds in smog chambers.

    Science.gov (United States)

    Pindado Jiménez, Oscar; Pérez Pastor, Rosa M; Vivanco, Marta G; Santiago Aladro, Manuel

    2013-03-15

    A method for quantifying secondary organic aerosol compounds (SOA) and water soluble secondary organic aerosol compounds (WSOA) produced from photo-oxidation of complex mixtures of volatile organic compounds (VOCs) in smog chambers by gas chromatography/mass spectrometry (GC/MS) has been developed. This method employs a double extraction with water and methanol jointly to a double derivatization with N,O-bis (trimethylsilil) trifluoroacetamide (BSTFA) and O-(2,3,4,5,6)-pentafluorobenzyl-hydroxylamine hydrochloride (PFBHA) followed by an analysis performed by GC/MS. The analytical procedure complements other methodologies because it can analyze SOA and WSOA compounds simultaneously at trace levels. As application, the methodology was employed to quantify the organic composition of aerosols formed in a smog chamber as a result of photo-oxidation of two different mixtures of volatile organic compounds: an anthropogenic mixture and a biogenic mixture. The analytical method allowed us to quantify up to 17 SOA compounds at levels higher than 20 ng m(-3) with reasonable recovery and a precision below 11%. Values found for applicability, selectivity, linearity, precision, recovery, detection limit, quantification limit and sensitivity demonstrated that the methodology can be satisfactorily applied to quantify SOA and WSOA. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Heavy metal accumulation and phytostabilisation potential of tree fine roots in a contaminated soil

    International Nuclear Information System (INIS)

    Brunner, Ivano; Luster, Joerg; Guenthardt-Goerg, Madeleine S.; Frey, Beat

    2008-01-01

    Root systems of Norway spruce (Picea abies) and poplar (Populus tremula) were long-term exposed to metal-contaminated soils in open-top chambers to investigate the accumulation of the heavy metals in the fine roots and to assess the plants suitability for phytostabilisation. The heavy metals from the contaminated soil accumulated in the fine roots about 10-20 times more than in the controls. The capacity to bind heavy metals already reached its maximum after the first vegetation period. Fine roots of spruce tend to accumulate more heavy metals than poplar. Copper and Zinc were mainly detected in the cell walls with larger values in the epidermis than in the cortex. The heavy metals accumulated in the fine roots made up 0.03-0.2% of the total amount in the soils. We conclude that tree fine roots adapt well to conditions with heavy metal contamination, but their phytostabilisation capabilities seem to be very low. - Long-term exposed fine roots of trees are well adapted to soils with high heavy metal contents, but their phytostabilisation capabilities are rather low

  8. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  10. E-P instability in the NSNS accumulator ring

    Energy Technology Data Exchange (ETDEWEB)

    Ruggiero, A.G.; Blaskiewicz, M.

    1997-08-01

    It has been speculated that the intensity limitation observed in the Los Alamos Proton Storage Ring (PSR) is caused by a coherent instability induced by the presence of pockets of electrons generated by scattering with the molecules of the vacuum residual gas. A theoretical explanation of the e-p instability of course does exist, and is similar to the one developed for the ion-induced instability in electron storage rings. Considering the large beam power (3 MW) involved in the NSNS Accumulator Ring, and the consequences caused by even a small amount of beam loss, we need to carefully assess the effects of electrons that may be generated in the vacuum chamber.

  11. The analysis of track chamber photographs using flying spot digitizers

    CERN Multimedia

    Powell, Brian W

    1966-01-01

    A vast quantity of data pours from the experiments on particle accelerators throughout the world. For example, over 300 000 photographs per week came from the three bubble chambers operating on the CERN PS at the end of 1965. The conventional method of processing these bubble chamber photographs is for each one of them to be examined ('scanned') to see whether it records an interesting particle interaction. The interesting photographs are then passed to hand operated measuring machines to obtain precise measurements of the particle trajectories recorded on the film. Similar measurements are carried out on photographs taken in film spark chamber experiments. This article on the Flying Spot Digitizers at CERN describes one of the most fruitful attempts to speed and make more accurate the process of analysis of bubble and spark chamber photographs. There are two types of Flying Spot Digitizer at CERN — the HPD or Hough Powell Device (named after Professor Hough and the author who, together, initiated the devel...

  12. Crystalline heterogeneities and instabilities in thermally convecting magma chamber

    Science.gov (United States)

    Culha, C.; Suckale, J.; Qin, Z.

    2016-12-01

    A volcanic vent can supply different densities of crystals over an eruption time period. This has been seen in Hawai'i's Kilauea Iki 1959 eruption; however it is not common for all Kilauea or basaltic eruptions. We ask the question: Under what conditions can homogenous magma chamber cultivate crystalline heterogeneities? In some laboratory experiments and numerical simulations, a horizontal variation is observed. The region where crystals reside is identified as a retention zone: convection velocity balances settling velocity. Simulations and experiments that observe retention zones assume crystals do not alter the convection in the fluid. However, a comparison of experiments and simulations of convecting magma with crystals suggest that large crystal volume densities and crystal sizes alter fluid flow considerably. We introduce a computational method that fully resolves the crystalline phase. To simulate basaltic magma chambers in thermal convection, we built a numerical solver of the Navier-Stoke's equation, continuity equation, and energy equation. The modeled magma is assumed to be a viscous, incompressible fluid with a liquid and solid phase. Crystals are spherical, rigid bodies. We create Rayleigh-Taylor instability through a cool top layer and hot bottom layer and update magma density while keeping crystal temperature and size constant. Our method provides a detailed picture of magma chambers, which we compare to other models and experiments to identify when and how crystals alter magma chamber convection. Alterations include stratification, differential settling and instabilities. These characteristics are dependent on viscosity, convection vigor, crystal volume density and crystal characteristics. We reveal that a volumetric crystal density variation may occur over an eruption time period, if right conditions are met to form stratifications and instabilities in magma chambers. These conditions are realistic for Kilauea Iki's 1959 eruption.

  13. Multiplicity counting from fission chamber signals in the current mode

    Energy Technology Data Exchange (ETDEWEB)

    Pázsit, I. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); Pál, L. [Centre for Energy Research, Hungarian Academy of Sciences, 114, POB 49, H-1525 Budapest (Hungary); Nagy, L. [Chalmers University of Technology, Department of Physics, Division of Subatomic and Plasma Physics, SE-412 96 Göteborg (Sweden); Budapest University of Technology and Economics, Institute of Nuclear Techniques, H-1111 Budapest (Hungary)

    2016-12-11

    In nuclear safeguards, estimation of sample parameters using neutron-based non-destructive assay methods is traditionally based on multiplicity counting with thermal neutron detectors in the pulse mode. These methods in general require multi-channel analysers and various dead time correction methods. This paper proposes and elaborates on an alternative method, which is based on fast neutron measurements with fission chambers in the current mode. A theory of “multiplicity counting” with fission chambers is developed by incorporating Böhnel's concept of superfission [1] into a master equation formalism, developed recently by the present authors for the statistical theory of fission chamber signals [2,3]. Explicit expressions are derived for the first three central auto- and cross moments (cumulants) of the signals of up to three detectors. These constitute the generalisation of the traditional Campbell relationships for the case when the incoming events represent a compound Poisson distribution. Because now the expressions contain the factorial moments of the compound source, they contain the same information as the singles, doubles and triples rates of traditional multiplicity counting. The results show that in addition to the detector efficiency, the detector pulse shape also enters the formulas; hence, the method requires a more involved calibration than the traditional method of multiplicity counting. However, the method has some advantages by not needing dead time corrections, as well as having a simpler and more efficient data processing procedure, in particular for cross-correlations between different detectors, than the traditional multiplicity counting methods.

  14. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons; Camara de ionizacao de eletretos: um novo metodo para deteccao e dosimetria de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Ghilardi, A J.P.

    1988-12-31

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of {gamma}-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF{sub 3} ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs.

  15. Uncertainty on Fatigue Damage Accumulation for Composite Materials

    DEFF Research Database (Denmark)

    Toft, Henrik Stensgaard; Sørensen, John Dalsgaard

    2009-01-01

    In the present paper stochastic models for fatigue damage accumulation for composite materials are presented based on public available constant and variable amplitude fatigue tests. The methods used for estimating the SN-curve and accumulated fatigue damage are presented.......In the present paper stochastic models for fatigue damage accumulation for composite materials are presented based on public available constant and variable amplitude fatigue tests. The methods used for estimating the SN-curve and accumulated fatigue damage are presented....

  16. Technical Note : A direct ray-tracing method to compute integral depth dose in pencil beam proton radiography with a multilayer ionization chamber

    NARCIS (Netherlands)

    Farace, Paolo; Righetto, Roberto; Deffet, Sylvain; Meijers, Arturs; Vander Stappen, Francois

    2016-01-01

    Purpose: To introduce a fast ray-tracing algorithm in pencil proton radiography (PR) with a multilayer ionization chamber (MLIC) for in vivo range error mapping. Methods: Pencil beam PR was obtained by delivering spots uniformly positioned in a square (45x45 mm(2) field-of-view) of 9x9 spots capable

  17. Pressure vessel rupture within a chamber: the pressure history on the chamber wall

    International Nuclear Information System (INIS)

    Baum, M.R.

    1989-04-01

    Generally there is a large number of pressure vessels containing high pressure gas on power stations and chemical plant. In many instances, particularly on power plant, these vessels are within the main building. If a pressure vessel were to fail, the surrounding structures would be exposed to blast loads and the forces resulting from jets of fluid issuing from the breached vessel. In the case where the vessel is in a relatively closed chamber there would also be a general overpressurisation of the chamber. At the design stage it is therefore essential to demonstrate that the plant could be safely shut down in the event of a pressure vessel failure, that is, it must be shown that the chamber will not collapse thus putting the building at risk or hazarding equipment essential for a safe shut down. Such an assessment requires the loads applied to the chamber walls, roof, etc. to be known. (author)

  18. Wet drift chambers for precise luminosity

    International Nuclear Information System (INIS)

    Anderson, B.E.; Kennedy, B.W.; Ahmet, K.; Attree, D.J.; Barraclough, G.A.; Cresswell, M.J.; Hayes, D.A.; Miller, D.J.; Selby, C.; Sherwood, P.

    1994-01-01

    A set of high-precision compact drift chambers has been a vital component of the OPAL luminosity monitor since the start of data-taking at LEP. They were augmented in 1992 by the addition of Small Angle Reference Chambers with a very similar design to the original chamber. The performance of the chambers is reviewed, highlighting both the importance of using polyalkylene glycol (Breox) to maintain a uniform and parallel electric field and the construction techniques used to sustain the required field strength. We describe some of the operating problems, with their solutions, and show how the chambers have been used in achieving a systematic error of 0.41% on the luminosity measurement. ((orig.))

  19. The Boycott effect in magma chambers

    Science.gov (United States)

    Blanchette, F.; Peacock, T.; Bush, J. W. M.

    2004-03-01

    We investigate the plausibility of the stratified Boycott effect as a source of layering in magma chambers. Crystal settling within the magma chamber will generate buoyant fluid near the sloping sidewalls whose vertical ascent may be limited by the ambient stratification associated with vertical gradients in SiO2. The resulting flow may be marked by a layered structure, each layer taking the form of a convection cell spanning the lateral extent of the magma chamber. Using parameters relevant to magma chambers, we estimate that such convection cells would be established over a timescale of a month and have a depth on the order of 4m, which is roughly consistent with field observations of strata within solidified chambers.

  20. Calibration and performance of a stirred benthic chamber

    Science.gov (United States)

    Buchholtz-ten Brink, M. R.; Gust, G.; Chavis, D.

    1989-07-01

    The physical and chemical boundary layer parameters characteristic for a benthic chamber were cross-calibrated by the use of two methods in the laboratory: (1) flush-mounted hot-film sensors, which measure the friction velocity u ∗, and (2) the alabaster dissolution technique, which measures the equivalent film thickness z. Tests of five stirring devices were made, using both techniques, to improve the stirring mechanism in the MANOP Lander flux chambers. The stirring device that was finally implemented consisted of four rods and produced spatially averaged friction velocities u ∗ ranging from 0.1 to 0.5 cm s -1 (i.e. mean film thickness z from 500 to 180 μm) when running at speeds from 3 to 9 rpm. The friction velocity field at the sediment surface is related to the rpm of the stirring device and the penetration depth of the chamber into the sediments; combinations of both can create z and u ∗ inside the chamber that duplicate those of many natural environments. The log-log calibration relationship found between u ∗ and transfer coefficients K' also provides a means to predict the mass-transfer resistance of solutes at the sediment-water interface from measurements of mean bottom stress.

  1. Drift Chambers detectors; Detectores de deriva

    Energy Technology Data Exchange (ETDEWEB)

    Duran, I; Martinez laso, L

    1989-07-01

    We present here a review of High Energy Physics detectors based on drift chambers. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysed, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author) 115 refs.

  2. The KEK 1 m hydrogen bubble chamber

    International Nuclear Information System (INIS)

    Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.

    1978-03-01

    A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)

  3. Robust estimation of track parameters in wire chambers

    International Nuclear Information System (INIS)

    Bogdanova, N.B.; Bourilkov, D.T.

    1988-01-01

    The aim of this paper is to compare numerically the possibilities of the least square fit (LSF) and robust methods for modelled and real track data to determine the linear regression parameters of charged particles in wire chambers. It is shown, that Tukey robust estimate is superior to more standard (versions of LSF) methods. The efficiency of the method is illustrated by tables and figures for some important physical characteristics

  4. Loss of ions in cavity ionization chambers

    International Nuclear Information System (INIS)

    Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.

    2005-01-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers

  5. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP.

  6. IFE chamber technology testing program in NIF and chamber development test plan

    International Nuclear Information System (INIS)

    Abdou, M.A.

    1995-01-01

    Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF

  7. Differences in CASA output according to the chamber type when analyzing frozen-thawed bull sperm.

    Science.gov (United States)

    Ibănescu, Iulian; Leiding, Claus; Ciornei, Ştefan Gregore; Roșca, Petru; Sfartz, Ioana; Drugociu, Dan

    2016-03-01

    As demonstrated by some authors, the type of analyzing chamber can greatly influence the results of computer-assisted sperm analysis (CASA). This study aimed to compare three of the disposable chamber types currently available on the market and to determine whether the CASA output may be significantly different among them. The semen from five Fleckvieh bulls was analyzed by CASA using three different disposable chambers: Leja (20μm), MofA (20μm) and Minitube (20μm), at three different time points: immediately after filling the chamber, at 6min, and also at 12min after filling. Sperm concentration was also determined using the Nucleocounter® NC-100™ device and the hemocytometer as standard methods. The results showed higher values in terms of total and progressive sperm motility for MofA compared to the other two chambers immediately after filling (pCASA only when the other methods are not available. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Impedances in lossy elliptical vacuum chambers

    International Nuclear Information System (INIS)

    Piwinski, A.

    1994-04-01

    The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)

  9. Numerical model of total artificial heart hemodynamics and the effect of its size on stress accumulation.

    Science.gov (United States)

    Marom, Gil; Chiu, Wei-Che; Slepian, Marvin J; Bluestein, Danny

    2014-01-01

    The total artificial heart (TAH) is a bi-ventricular mechanical circulatory support device that replaces the heart in patients with end-stage congestive heart failure. The device acts as blood pump via pneumatic activation of diaphragms altering the volume of the ventricular chambers. Flow in and out of the ventricles is controlled by mechanical heart valves. The aim of this study is to evaluate the flow regime in the TAH and to estimate the thrombogenic potential during systole. Toward that goal, three numerical models of TAHs of differing sizes, that include the deforming diaphragm and the blood flow from the left chamber to the aorta, are introduced. A multiphase model with injection of platelet particles is employed to calculate their trajectories. The shear stress accumulation in the three models are calculated along the platelets trajectories and their probability density functions, which represent the `thrombogenic footprint' of the device are compared. The calculated flow regime successfully captures the mitral regurgitation and the flows that open and close the aortic valve during systole. Physiological velocity magnitudes are found in all three models, with higher velocities and increased stress accumulation predicted for smaller devices.

  10. Investigation of very long jet chambers

    Energy Technology Data Exchange (ETDEWEB)

    Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P

    1986-04-01

    The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP. (orig.).

  11. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1995-01-01

    Chamber transport is an important area of study for heavy ion fusion. Final focus and chamber-transport are high leverage areas providing opportunities to significantly decrease the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (approx-lt 0.003 torr), ballistic or nearly-ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (approx-gt.1 torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber then transporting it at small radius (∼ 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity

  12. Some simple approaches used in the construction of multiwire proportional chambers

    International Nuclear Information System (INIS)

    Staric, M.; Zavrtanik, D.; Kernel, G.; Ljubljana Univ.

    1983-01-01

    A simple method of manufacturing multiwire proportional chambers is described on an example of a 160 mmx160 mm chamber. Using a microscope the wires of anode planes are positioned to an accuracy of about 10 μm. Wire tensions are checked by comparing their natural frequencies to the notes of a musical instrument. A description of a drum-like device for foil stretching is also given. (orig.)

  13. Poster - 19: Investigation of Electron Reference Dosimetry Based on Optimal Chamber Shift

    Energy Technology Data Exchange (ETDEWEB)

    Zhan, Lixin; Jiang, Runqing; Liu, Baochang; Osei, Ernest [Grand River Regional Cancer Centre (Canada)

    2016-08-15

    An addendum/revision to AAPM TG-51 electron reference dosimetry is highly expected to meet the clinical requirement with the increasing usage of new ion chambers not covered in TG-51. A recent study, Med. Phys. 41, 111701, proposed a new fitting equation for the beam quality conversion factor k’{sub Q} to a wide spectrum of chambers. In the study, an optimal Effective Point of Measurement (EPOM) from Monte Carlo calculations was recommended and the fitting parameters to k’{sub Q} was based on it. We investigated the absolute dose obtained based on the optimal EPOM method and the original TG-51 method with k’{sub R50} determined differently. The results showed that using the Markus curve is a better choice than the well-guarded chamber fitting for an IBA PPC-05 parallel plate chamber if we need to strictly follow the AAPM TG-51 protocol. We also examined the usage of the new fitting equation with measurement performed at the physical EPOM, instead of the optimal EPOM. The former is more readily determined and more practical in clinics. Our study indicated that the k’{sub Q} fitting based on the optimal EPOM can be used to measurement at the physical EPOM with no significant clinical impact. The inclusion of Farmer chamber gradient correction P{sub gr} in k’{sub Q}, as in the mentioned study, asks for the precise positioning of chamber center at dref. It is not recommended in clinics to avoid over-correction for low electron energies, especially for an institute having matching Linacs implemented.

  14. Multiwire proportional chamber and multistage avalanche chamber with low concentration photoionization gas

    International Nuclear Information System (INIS)

    Zhao Pingde; Xu Zhiqing; Tang Xiaowei

    1986-01-01

    The characteristics of multiwire proportional chamber and multistage avalanche chamber filled with argon and photoionization gas (C 2 H 5 ) 3 N were measured. The spatial resolution curves and output pulse height spectra were measured as well. Low concentration (C 2 H 5 ) 3 N can play an effective part in quenching. At very low concentration, the phenomena of avalanche transverse expansion was observed obviously

  15. PEP quark search proportional chambers

    Energy Technology Data Exchange (ETDEWEB)

    Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)

    1981-04-01

    Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.

  16. Conceptual Engineering Method for Attenuating He Ion Interactions on First Wall Components in the Fusion Test Facility (FTF) Employing a Low-Pressure Noble Gas

    International Nuclear Information System (INIS)

    Gentile, C.A.; Blanchard, W.R.; Kozub, T.; Priniski, C.; Zatz, I.; Obenschain, S.

    2009-01-01

    It has been shown that post detonation energetic helium ions can drastically reduce the useful life of the (dry) first wall of an IFE reactor due to the accumulation of implanted helium. For the purpose of attenuating energetic helium ions from interacting with first wall components in the Fusion Test Facility (FTF) target chamber, several concepts have been advanced. These include magnetic intervention (MI), deployment of a dynamically moving first wall, use of a sacrificial shroud, designing the target chamber large enough to mitigate the damage caused by He ions on the target chamber wall, and the use of a low pressure noble gas resident in the target chamber during pulse power operations. It is proposed that employing a low-pressure (∼ 1 torr equivalent) noble gas in the target chamber will thermalize energetic helium ions prior to interaction with the wall. The principle benefit of this concept is the simplicity of the design and the utilization of (modified) existing technologies for pumping and processing the noble ambient gas. Although the gas load in the system would be increased over other proposed methods, the use of a 'gas shield' may provide a cost effective method of greatly extending the first wall of the target chamber. An engineering study has been initiated to investigate conceptual engineering methods for implementing a viable gas shield strategy in the FTF.

  17. Argus target chamber

    International Nuclear Information System (INIS)

    Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.

    1975-01-01

    A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation

  18. A special mini-extrapolation chamber for calibration of 90Sr+90Y sources

    International Nuclear Information System (INIS)

    Oliveira, Mercia L; Caldas, Linda V E

    2005-01-01

    90 Sr+ 90 Y applicators are commonly utilized in brachytherapy, including ophthalmic procedures. The recommended instruments for the calibration of these applicators are extrapolation chambers, which are ionization chambers that allow the variation of their sensitive volume. Using the extrapolation method, the absorbed dose rate at the applicator surface can be determined. The aim of the present work was to develop a mini-extrapolation chamber for the calibration of 90 Sr+ 90 Y beta ray applicators. The developed mini-chamber has a 3.0 cm outer diameter and is 11.3 cm in length. An aluminized polyester foil is used as the entrance window while the collecting electrode is made of graphited polymethylmethacrylate. This mini-chamber was tested in 90 Sr+ 90 Y radiation beams from a beta particle check source and with a plane ophthalmic applicator, showing adequate results

  19. Methods and apparatus for cleaning objects in a chamber of an optical instrument by generating reactive ions using photon radiation

    Science.gov (United States)

    Klebanoff, Leonard E.; Delgado, Gildardo R.; Hollenshead, Jeromy T.; Umstadter, Karl R.; Starodub, Elena; Zhuang, Guorong V.

    2015-10-13

    An optical instrument, including a chamber, an object exposed to an interior of the chamber, a source of low-pressure gas, the gas comprising at least one of low-pressure molecular hydrogen gas, low-pressure molecular oxygen and a low-pressure noble gas, the source of low pressure gas being fluidly coupled to the chamber, a low voltage source electrically coupled between the object and a remaining portion of the instrument that is exposed to the interior of the chamber so as to maintain the object at a low voltage relative to the remaining portion, and an EUV/VUV light source adapted to direct EUV/VUV light through the low pressure gas in the chamber onto the object. In such a system, when the EUV/VUV light source is activated ions of the low-pressure gas are formed and directed to the object. The ions may be ions of Hydrogen, Oxygen or a noble gas.

  20. Cylindrical ionization chamber with compressed krypton

    International Nuclear Information System (INIS)

    Kuz'minov, V.V.; Novikov, V.M.; Pomanskii, A.A.; Pritychenko, B.V.; Viyar, J.; Garcia, E.; Morales, A.; Morales, J.; Nunes-Lagos, R.; Puimedon, J.; Saens, K.; Salinas, A.; Sarsa, M.

    1993-01-01

    A cylindrical ionization chamber with a grid is used to search for double positron decay and atomic electron conversion to a positron in 78 Kr. Krypton is the working gas material of the chamber. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. The energy resolution is 2.1% for an energy of 1.84 MeV (the source of γ-quanta is 88 Y) when the chamber is filled with a mixture of Kr+0.2% H 2 under a pressure of 25 atm

  1. Advances on fission chamber modelling

    International Nuclear Information System (INIS)

    Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob

    2013-06-01

    In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the

  2. An electrodeless drift chamber

    International Nuclear Information System (INIS)

    Allison, J.; Barlow, R.J.; Bowdery, C.K.; Duerdoth, I.; Rowe, P.G.

    1982-01-01

    We describe a chamber in which the drift field is controlled by the deposition of electrostatic charge on an insulating surface. The chamber operates with good efficiency and precision for observed drift distances of up to 45 cm, promises to be extremely robust and adaptable and offers a very cheap way of making particle detectors. (orig.)

  3. DELPHI time projection chamber

    CERN Multimedia

    1989-01-01

    The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.

  4. Measurement of the positron-drift time relation of a high-pressure drift chamber

    International Nuclear Information System (INIS)

    Pruefert, W.

    1989-04-01

    As a test of its performance, the measurement of the drift time versus drift distance relation of a high pressure drift chamber using cosmic rays is described. Two multiwire proportional chambers, mounted above and below the detector, are used to define the track of the cosmic particle in the drift chamber. The drift chamber is read out by FADCs (Flash Analog to Digital Converter), and the drift time is determined from the FADC signals by the DOS- (Difference Of Samples) method. The measured drift time versus drift distance relation showed good agreement with the relation, which is expected from the spatial dependence of the electric field and the dependence of the drift velocity on this field. (orig.) [de

  5. Properties of electret ionization chambers for routine dosimetry in photon radiation fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1985-01-01

    The main properties of photon routine dosemeters are their energy and angular dependence as well as their measuring range and accuracy. The determination of radiation exposure from dosemeter response is based on the choice of an appropriate conversion factor taking into account the influence of body backscattering on the dosemeter response. Measuring range and accuracy of an electret ionization chamber first of all depend on electret stability, methods of charge measurement, and geometry of the chamber. The dosemeter performance is described for an electret ionization chamber which was designed for application to routine monitoring of radiation workers. (author)

  6. Non-financial Results of Performance Indicators of Trade and Industry Chambers in Ukraine

    Directory of Open Access Journals (Sweden)

    Bogdana V. Aleksandrova

    2014-03-01

    Full Text Available The article deals with non-financial results review of Trade and Industry Chamber, the assessment of competitiveness in the Ukrainian market. To achieve the desired goal we should do the following: 1.\tIdentify categories of research 2.\tSystemize available statistics. 3.\tTo evaluate dynamics of main categories 4.\tConduct an assessment of non-financial indicators of Trade and Industry Chamber 5.\tIdentify the level of competitiveness of Trade and Industry Chamber of Ukraine on domestic market. Methods used by author to address these issues: index-linked, method of correlation analysis, method of expert assessment. As a result of the study, non-financial indicators of organization’s activities have been analyzed, the dynamics of membership base and the scope of delivered services have been identified as well as the level of organization’s competitiveness. The most promising services have been highlighted.

  7. Chamber propagation physics for heavy ion fusion

    International Nuclear Information System (INIS)

    Callahan, D.A.

    1996-01-01

    Chamber transport is a key area of study for heavy ion fusion. Final focus and chamber transport are high leverage areas providing opportunities to decrease significantly the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (below about 0.003 Torr), ballistic or nearly ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (above about 0.1 Torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber and then transporting it at small radius (about 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity. (orig.)

  8. How to build a cloud chamber?

    International Nuclear Information System (INIS)

    Mariaud, C.

    2012-01-01

    The cloud chamber had its heyday in the first half of last century and allowed the discovery of new particles such as the anti-electron, the muon and the neutral and the charged kaon. The bubble chamber replaced it in the mid fifties. This article recalls the principle of the cloud chamber and shows, in a detailed way, how to proceed to build one with on-the-shelf materials. This design is based on the use of isopropanol whose liquefaction through the form of droplets materializes the track of the particle and on the use of combined Peltier cells (instead of CO 2 snow) to cool the chamber. This cloud chamber has been successfully used in schools to observe particles mainly electrons, alphas and muons generated by cosmic rays. (A.C.)

  9. Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Dias, Daniel Menezes

    2010-01-01

    Pencil ionization chambers are used for beam dosimetry in computed tomography equipment (CT). In this study, a new calibration methodology was established, in order to make the Calibration Laboratory of Instituto de Pesquisas Energeticas e Nucleares (LCI) suitable to international metrological standards, dealing with specific procedures for calibration of these chambers used in CT. Firstly, the setup for the new RQT radiation qualities was mounted, in agreement with IEC61267 from the International Electrotechnical Commission (IEC). After the establishment of these radiation qualities, a specific calibration methodology for pencil ionization chambers was set, according to Technical Report Series No. 457, from the International Atomic Energy Agency (IAEA), which describes particularities of the procedure to be followed by the Secondary Standard Dosimetry Laboratories (SSDL's), concerning to collimation and positioning related to the radiation beam. Initially, PPV (kV) measurements and the determination of copper additional filtrations were carried out, measuring the half value layers (HVL) recommended by the IEC 61267 standard, after that the RQT 8, RQT 9 and RQT 10 radiation quality references were established. For additional filters, aluminum and copper of high purity (around 99.9%) were used. RQT's in thickness of copper filters equivalent to the set 'RQR (Al) + Additional Filtration (Cu)' was directly found by an alternative methodology used to determine additional filtrations, which is a good option when RQR's have not the possibility of be setting up. With the establishment of this new methodology for the ionization pencil chambers calibration, the LCI is ready to calibrate these instruments according to the most recent international standards. Therefore, an improvement in calibration traceability, as well as in metrological services offered by IPEN to all Brazil is achieved. (author)

  10. A mathematical model of aerosol holding chambers

    DEFF Research Database (Denmark)

    Zak, M; Madsen, J; Berg, E

    1999-01-01

    A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London...

  11. Prototype exposure chamber of radon for animal experiments

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yuji; Koizumi, Akira; Yonehara, Hidenori; Shimo, Michikuni; Inaba, Jiro [National Institute of Radiological Sciences, Chiba (Japan)

    1998-12-31

    To evaluate a dose conversion factor from the `Working Level of Month` (WLM) of radon to the absorbed dose (mGy), the quality of radon and its progeny was assessed, and exposures controlled for each deposition region were planed as follows: 1) exposure of radon gas to the entire respiratory tract, 2) exposure of `unattached` fractions to the upper respiratory tract, 3) exposure of `attached` fractions onto ultrafine particles to the deep lung, 4) exposure of `attached` fractions onto fine particles to the lower respiratory tract, 5) exposure of `attached` fractions onto coarse particles to the upper respiratory tract. In this preliminary study, a prototype exposure system of radon and its progeny for small rodents was designed. A whole body exposure chamber with a volume of about 0.5 m{sup 3} was used, which it held 20 rats. The aging and mixing chamber separated by the exposure chamber had a volume of about 1 m{sup 3}. As career aerosols of radon progeny, carnauba wax aerosols as solid particles, DOS aerosols as liquid particles and NaCl aerosols as hygroscopic particles were selected. These aerosols generated using a vaporization-condensation method and/or an electrical classification method were almost monodisperse with {sigma}{sub g} of <1.2. The monitoring data on biologically related gases showed an importance in the oxygen injection system and the carbon dioxide absorption system. (author)

  12. Quality control of ATLAS muon chambers

    CERN Document Server

    Fabich, Adrian

    ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...

  13. Hyperbaric and hypobaric chamber fires: a 73-year analysis.

    Science.gov (United States)

    Sheffield, P J; Desautels, D A

    1997-09-01

    Fire can be catastrophic in the confined space of a hyperbaric chamber. From 1923 to 1996, 77 human fatalities occurred in 35 hyperbaric chamber fires, three human fatalities in a pressurized Apollo Command Module, and two human fatalities in three hypobaric chamber fires reported in Asia, Europe, and North America. Two fires occurred in diving bells, eight occurred in recompression (or decompression) chambers, and 25 occurred in clinical hyperbaric chambers. No fire fatalities were reported in the clinical hyperbaric chambers of North America. Chamber fires before 1980 were principally caused by electrical ignition. Since 1980, chamber fires have been primarily caused by prohibited sources of ignition that an occupant carried inside the chamber. Each fatal chamber fire has occurred in an enriched oxygen atmosphere (> 28% oxygen) and in the presence of abundant burnable material. Chambers pressurized with air (Hyperbaric Medical Society's Chamber Experience and Mishap Database. This epidemiologic review focuses on information learned from critical analyses of chamber fires and how it can be applied to safe operation of hypobaric and hyperbaric chambers.

  14. Determination of the thermal and epithermal neutron sensitivities of an LBO chamber

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Satoru; Kotani, Kei; Kajimoto, Tsuyoshi; Tanaka, Kenichi [Hiroshima University, Quantum Energy Applications, Graduate School of Engineering, Higashi-Hiroshima (Japan); Sato, Hitoshi; Nakajima, Erika [Ibaraki Prefectural University of Health Science, Radiological Sciences, Ibaraki (Japan); Shimazaki, Takuto [Hiroshima University, Quantum Energy Applications, Graduate School of Engineering, Higashi-Hiroshima (Japan); Delta Kogyo Co., Ltd., Hiroshima (Japan); Suda, Mitsuru; Hamano, Tsuyoshi [National Institute of Radiological Sciences, Chiba-Shi, Chiba (Japan); Hoshi, Masaharu [Hiroshima University, Institute for Peace Science, Hiroshima (Japan)

    2017-08-15

    An LBO (Li{sub 2}B{sub 4}O{sub 7}) walled ionization chamber was designed to monitor the epithermal neutron fluence in boron neutron capture therapy clinical irradiation. The thermal and epithermal neutron sensitivities of the device were evaluated using accelerator neutrons from the {sup 9}Be(d, n) reaction at a deuteron energy of 4 MeV (4 MeV d-Be neutrons). The response of the chamber in terms of the electric charge induced in the LBO chamber was compared with the thermal and epithermal neutron fluences measured using the gold-foil activation method. The thermal and epithermal neutron sensitivities obtained were expressed in units of pC cm{sup 2}, i.e., from the chamber response divided by neutron fluence (cm{sup -2}). The measured LBO chamber sensitivities were 2.23 x 10{sup -7} ± 0.34 x 10{sup -7} (pC cm{sup 2}) for thermal neutrons and 2.00 x 10{sup -5} ± 0.12 x 10{sup -5} (pC cm{sup 2}) for epithermal neutrons. This shows that the LBO chamber is sufficiently sensitive to epithermal neutrons to be useful for epithermal neutron monitoring in BNCT irradiation. (orig.)

  15. HVAC&R Equipment Environmental Chambers

    Data.gov (United States)

    Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...

  16. Carbon dioxide gas hydrates accumulation in freezing and frozen sediments

    Energy Technology Data Exchange (ETDEWEB)

    Chuvilin, E.; Guryeva, O. [Moscow State Univ., Moscow (Russian Federation). Dept. of Geology

    2008-07-01

    Carbon dioxide (CO{sub 2}) hydrates and methane hydrates can be formed, and exist under natural conditions. The permafrost area has been considered as an environment for the potential disposal of CO{sub 2}. The favorable factors for preserving CO{sub 2} in liquid and gas hydrate states in frozen sediments and under permafrost horizons are great thickness of frozen sediments; low permeability in comparison with thawed sediments; and favourable conditions for hydrates formation. Therefore, research on the formation and existence conditions of CO{sub 2} gas hydrates in permafrost and under permafrost sediments are of great importance for estimation of CO{sub 2} disposal conditions in permafrost, and for working out specific sequestration schemes. This paper presented the results of an experimental study on the process of carbon dioxide (CO{sub 2}) gas hydrates formation in the porous media of sediments under positive and negative temperatures. Sediment samples of various compositions including those selected in the permafrost area were used. The research was conducted in a special pressure chamber, which allowed to monitor pressure and temperature. The study used the monitoring results in order to make quantitative estimation of the kinetics of CO{sub 2} hydrates accumulation in the model sediments. Results were presented in terms of kinetics of CO{sub 2} hydrates accumulation in the porous media at positive and negative temperatures; kinetics of CO{sub 2} hydrates accumulation in various porous media; gas hydrate-former influence on kinetics of hydrates accumulation in frozen sediments; and influence of freezing on CO{sub 2} hydrates accumulation in porous media. It was concluded that hydrate accumulation took an active place in porous media not only under positive, but also under high negative temperatures, when the water was mainly in the form of ice in porous media. 27 refs., 3 tabs., 5 figs.

  17. Micro plate fission chamber development

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun

    2014-01-01

    To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)

  18. Ionization chamber for smoke detector and the like

    International Nuclear Information System (INIS)

    Rork, G.D.; Thorp, E.J.; Zegarski, R.J.

    1985-01-01

    This invention relates to detectors of the ionization type for detecting airborne particulate matter and, in particular, to the construction of an ionization chamber for such a detector. This invention may be used for detecting a variety of materials, such as dust, fog and the like, but is particularly useful for detecting combustion products such as smoke. The smoke detector ionization chamber has two electrodes connected to a source of electric power; means defining access openings for enabling air flow into and out of the chamber; and means for causing ionization within the chamber. It has control structure means within the chamber in the path of the airflow cooperating with the electrodes to establish within the chamber an electric field having a higher intensity close to the access openings and a lower intensity in the remainder of the chamber without significantly impairing the flow of neutral particles into the chamber. The control structure reduces airflow velocity within the chamber without adversely affecting the access of airborne particles to the chamber

  19. Liquid Wall Chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W R

    2011-02-24

    The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.

  20. MICROMEGAS chambers for hadronic calorimetry at a future linear collider

    CERN Document Server

    Adloff, C.; Blaha, J.; Cap, S.; Chefdeville, M.; Colas, P.; Dalmaz, A.; Drancourt, C.; Espargiliere, A.; Gaglione, R.; Gallet, R.; Geffroy, N.; Giomataris, I.; Jaquemier, J.; Karyotakis, Y.; Peltier, F.; Prast, J.; Vouters, G.

    2009-01-01

    Prototypes of MICROMEGAS chambers, using bulk technology and analog readout, with 1x1cm2 readout segmentation have been built and tested. Measurements in Ar/iC4H10 (95/5) and Ar/CO2 (80/20) are reported. The dependency of the prototypes gas gain versus pressure, gas temperature and amplification gap thickness variations has been measured with an 55Fe source and a method for temperature and pressure correction of data is presented. A stack of four chambers has been tested in 200GeV/c and 7GeV/c muon and pion beams respectively. Measurements of response uniformity, detection efficiency and hit multiplicity are reported. A bulk MICROMEGAS prototype with embedded digital readout electronics has been assembled and tested. The chamber layout and first results are presented.

  1. Chamber wall response to target implosion in inertial fusion reactors : new and critical assessments

    International Nuclear Information System (INIS)

    Hassanein, A.; Morozov, V.

    2002-01-01

    The chamber walls in inertial fusion energy (IFE) reactors are exposed to harsh conditions following each target implosion. Key issues of the cyclic IFE operation include intense photon and ion deposition, wall thermal and hydrodynamic evolution, wall erosion and fatigue lifetime, and chamber clearing and evacuation to ensure desirable conditions prior to target implosion. Several methods for wall protection have been proposed in the past, each having its own advantages and disadvantages. These methods include use of solid bare walls, gas-filled cavities, and liquid walls/jets. Detailed models have been developed for reflected laser light, emitted photons, and target debris deposition and interaction with chamber components and have been implemented in the comprehensive HEIGHTS software package. The hydrodynamic response of gas filled cavities and photon radiation transport of the deposited energy has been calculated by means of new and advanced numerical techniques. Fragmentation models of liquid jets as a result of the deposited energy have also been developed, and the impact on chamber clearing dynamics has been evaluated. Th focus of this study is to critically assess the reliability and the dynamic response of chamber walls in various proposed protection methods for IFE systems. Of particular concern is the effect on wall erosion lifetime of various erosion mechanisms, such as vaporization, chemical and physical sputtering, melt/liquid splashing and explosive erosion, and fragmentation of liquid walls

  2. Beam test of a full-length prototype of the BESIII drift chamber with the readout electronics

    International Nuclear Information System (INIS)

    Qin, Z.H.; Chen, Y.B.; Sheng, H.Y.; Wu, L.H.; Liu, J.B.; Zhuang, B.A.; Jiang, X.S.; Zhao, Y.B.; Zhu, K.J.; Yan, Z.K.; Chen, C.; Xu, M.H.; Wang, L.; Ma, X.Y.; Tang, X.; Liu, R.G.; Jin, Y.; Zhu, Q.M.; Zhang, G.F.; Wu, Z.; Li, R.Y.; Zhao, P.P.; Dai, H.L.; Li, X.P.; Li, J.

    2007-01-01

    A full-length prototype of the BESIII drift chamber together with its readout electronics was built and a beam test was performed. Two different methods, namely 'single-threshold method' and 'double-threshold method' for timing measurement, were studied. Test results show that the BESIII drift chamber and its readout electronics can reach their design specifications. The 'double-threshold method' results in a better timing accuracy and noise suppression capabilities as compared with the 'single-threshold method'

  3. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  4. High resolution drift chambers

    International Nuclear Information System (INIS)

    Va'vra, J.

    1985-07-01

    High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs

  5. Continuously live image processor for drift chamber track segment triggering

    International Nuclear Information System (INIS)

    Berenyi, A.; Chen, H.K.; Dao, K.

    1999-01-01

    The first portion of the BaBar experiment Level 1 Drift Chamber Trigger pipeline is the Track Segment Finder (TSF). Using a novel method incorporating both occupancy and drift-time information, the TSF system continually searches for segments in the supercells of the full 7104-wire Drift Chamber hit image at 3.7 MHz. The TSF was constructed to operate in a potentially high beam-background environment while achieving high segment-finding efficiency, deadtime-free operation, a spatial resolution of 5 simulated physics events

  6. The Mark II Vertex Drift Chamber

    International Nuclear Information System (INIS)

    Alexander, J.P.; Baggs, R.; Fujino, D.

    1989-03-01

    We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO 2 mixtures are presented. 10 refs., 12 figs., 1 tab

  7. Bicone vacuum chamber for ISR intersection

    CERN Multimedia

    1975-01-01

    This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.

  8. Microstrip gas chamber on thin-film Pestov glass and micro gap chamber

    International Nuclear Information System (INIS)

    Gong, W.G.; Harris, J.W.; Wieman, H.

    1994-07-01

    The authors report developments of the Microstrip Gas Chamber on thin-film Pestov glass and the Micro Gap Chamber. By coating a thin-layer of low-resistive, electronically-conductive glass on various substrates (including quartz and ceramics), they built MSGCs of high gain stability and low leakage current. They were tested in Ar-CH 4 (10%) and He-C 2 H 6 (50%) gas mixtures. Energy resolutions of 17-20% were measured for 6keV x-rays. This design can make the choice of substrate less important, save the cost of ion-implantation, and use less glass material. Micro Gap Chamber was successfully tested in He-C 2 H 6 (50%) and Ar-C 2 H 6 (50%) gas mixtures. Energy resolutions of about 20% were obtained. Both detectors are expected to have high rate capability

  9. Monte Carlo studies on Cathode Strip/Pad Chambers for the ALICE Di-Muon Arm

    Energy Technology Data Exchange (ETDEWEB)

    Wurzinger, R.; Le Bornec, Y.; Willis, N.

    1996-04-01

    A general overview about the properties of Cathode Strip and Pad Chambers is given. Position finding methods are discussed and compared within Monte Carlo studies. Noise contributions and their minimization are discussed. Pad chambers allow a two-dimensional readout with spatial resolution of {sigma} < 100 {mu}m in direction parallel to the anode wire. The resolution normal to the anode wire depends mainly on the wire spacing. Special attention is paid on the double-hit resolution capability of the pad chamber. An outlook is given on the possible utilisation of Cathode Pad Chambers in the Di-Muon Arm of the ALICE detector at LHC. (author). 44 refs.

  10. Uniform, stable supply of medium for in vitro cell culture using a robust chamber

    Science.gov (United States)

    Wei, Juan; Liu, Chong; Jiang, Yang; Liu, Tao; Chen, Li; Liu, Bo; Li, Jingmin

    2018-06-01

    A uniform, stable supply of medium is important for in vitro cell culture. In this paper, a microfluidic device is presented for culturing cells inside a robust chamber with continuous perfusion of medium. The device consists of a main channel, two bifurcated channels and a culture chamber. The culture chamber connects to the bifurcated channels via multiple paths, and distributes symmetrically on the main channel, to improve the efficiency of medium exchange. Furthermore, regular polygonal chambers with various numbers of edges have been designed, to study the effects of chamber shape on flow fields. The finite element method has been employed to predict the effects of multiple paths on the uniformity and stability of flow fields in the culture chamber. Particle tracking technology has been used to evaluate the flow fields in the chambers, and PC-12 cells have been cultured using the microfluidic device, to test its validity. The results of simulation and experiment indicate that the microfluidic design could provide a continuous interstitial-like flow microenvironment, with a relatively stable and uniform supply of medium.

  11. Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beams

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.; Pimpinella, M.; Bovi, M.

    2002-01-01

    The factor K wall to correct for photon attenuation and scatter in the wall of ionization chambers for 60 Co air-kerma measurement has been traditionally determined by a procedure based on a linear extrapolation of the chamber current to zero wall thickness. Monte Carlo calculations by Rogers and Bielajew (1990 Phys. Med. Biol. 35 1065-78) provided evidence, mostly for chambers of cylindrical and spherical geometry, of appreciable deviations between the calculated values of K wall and those obtained by the traditional extrapolation procedure. In the present work an experimental method other than the traditional extrapolation procedure was used to determine the K wall factor. In this method the dependence of the ionization current in a cylindrical chamber was analysed as a function of an effective wall thickness in place of the physical (radial) wall thickness traditionally considered in this type of measurement. To this end the chamber wall was ideally divided into distinct regions and for each region an effective thickness to which the chamber current correlates was determined. A Monte Carlo calculation of attenuation and scatter effects in the different regions of the chamber wall was also made to compare calculation to measurement results. The K wall values experimentally determined in this work agree within 0.2% with the Monte Carlo calculation. The agreement between these independent methods and the appreciable deviation (up to about 1%) between the results of both these methods and those obtained by the traditional extrapolation procedure support the conclusion that the two independent methods providing comparable results are correct and the traditional extrapolation procedure is likely to be wrong. The numerical results of the present study refer to a cylindrical cavity chamber like that adopted as the Italian national air-kerma standard at INMRI-ENEA (Italy). The method used in this study applies, however, to any other chamber of the same type. (author)

  12. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  13. Calibration of ARI QC ionisation chambers using the Australian secondary standards for activity

    International Nuclear Information System (INIS)

    Mo, L.; Van Der Gaast, H.A.; Alexiev, D.; Butcher, K.S.A.; Davies, J.

    1999-01-01

    The Secondary Standard Activity Laboratory (SSAL) in ANSTO routinely provides standardised radioactive sources, traceable activity measurements and custom source preparation services to customers. The most important activity carried out is the calibration of ionisation chambers located in the Quality Control (QC) section of Australian Radioisotopes (ARI). This ensures that their activity measurements are traceable to the Australian primary methods of standardisation. ARI QC ionisation chambers are calibrated for 99m Tc, 67 Ga, 131 I, 201 Tl and 153 Sm. The SSAL has a TPA ionisation chamber, which has been directly calibrated against a primary standard for a variety of radioactive nuclides. Calibration factors for this chamber were determined specifically for the actual volumes (5ml for 99m Tc, 131 I, 2ml for 67 Ga, 201 Tl and 3 ml for 153 Sm) and types of vial (Wheaton) which are routinely used at ARI. These calibration factors can be used to accurately measure the activity of samples prepared by ARI. The samples can subsequently be used to calibrate the QC ionisation chambers. QC ionisation chambers are re-calibrated biannually

  14. Molecular desorption of stainless steel vacuum chambers irradiated with 42 MeV/u lead ions

    CERN Document Server

    Mahner, E; Laurent, Jean Michel; Madsen, N

    2003-01-01

    In preparation for the heavy ion program of the Large Hadron Collider at CERN, accumulation and cooling tests with lead ion beams have been performed in the Low Energy Antiproton Ring. These tests have revealed that due to the unexpected large outgassing of the vacuum system, the dynamic pressure of the ring could not be maintained low enough to reach the required beam intensities. To determine the actions necessary to lower the dynamic pressure rise, an experimental program has been initiated for measuring the molecular desorption yields of stainless steel vacuum chambers by the impact of 4.2 MeV/u lead ions with the charge states +27 and +53. The test chambers were exposed either at grazing or at perpendicular incidence. Different surface treatments (glow discharges, nonevaporable getter coating) are reported in terms of the molecular desorption yields for H/sub 2 /, CH/sub 4/, CO, Ar, and CO/sub 2/. (16 refs).

  15. Estimation of steam-chamber extent using 4D seismic

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, M. [Waseda Univ., Waseda (Japan); Endo, K. [Japan Canada Oil Sands Ltd., Calgary, AB (Canada); Onozuka, S. [Japan Oil, Gas and Metals National Corp., Tokyo (Japan)

    2009-07-01

    The steam-assisted gravity drainage (SAGD) technique is among the most effective steam injection methods and is widely applied in Canadian oil-sand reservoirs. The SAGD technology uses hot steam to decrease bitumen viscosity and allow it to flow. Japan Canada Oil Sands Limited (JACOS) has been developing an oil-sand reservoir in the Alberta's Hangingstone area since 1997. This paper focused on the western area of the reservoir and reported on a study that estimated the steam-chamber extent generated by horizontal well pairs. It listed steam injection start time for each well of the western area. Steam-chamber distribution was determined by distinguishing high temperature and high pore-pressure zones from low temperature and high pore-pressure zones. The bitumen recovery volume in the steam-chamber zone was estimated and compared with the actual cumulative production. This paper provided details of the methodology and interpretation procedures for the quantitative method to interpret 4D-seismic data for a SAGD process. A procedure to apply a petrophysical model was demonstrated first by scaling laboratory measurements to field-scale applications, and then by decoupling pressure and temperature effects. The first 3D seismic data in this study were already affected by higher pressures and temperatures. 11 refs., 3 tabs., 12 figs.

  16. Measurement of radioactive gases. Study of SACM type CD2 differential chamber

    International Nuclear Information System (INIS)

    Benezech, G.

    1963-01-01

    This study aims at precising practical conditions of use of a circulation chamber to measure the activity of beta- and gamma-emitting radioactive gases. Results more particularly concern the SACM type CD 2 differential chamber but can easily be adapted to any other chamber type. Calibration calculations allow the definition of the field of use of this chamber. It appears that this apparatus will not generally allow a fine dosimetry of radioactive gases as the method is not selective and requires the knowledge of the gas nature. The author presents the operation principle, describes the experimental assembly, and discusses its performance in the case of a linear assembly and of a logarithmic assembly. He reports the calibration process and calculations (calculation of the ionization current with respect to gas activity, experimental measurement of this ionization current with respect to activity) [fr

  17. Multi-stage low-pressure avalanche chamber

    International Nuclear Information System (INIS)

    Zanevskij, Yu.V.; Peshekhonov, V.D.; Smykov, L.P.

    1985-01-01

    A multi-stage avalanche-chamber filled with isobutane operating at the pressure of 6 torr is described. The chamber comprises an amplifying gap, drift gap and multiwire proportional chamber with interelectrode gaps equal to 4 mm. The anode plane of the proportional chamber is winded of wire 2 μm in diameter with 2 mm pitch. The cathode are winded orthogonally to anode wires of wire 50 μm in diameter with 1 mm pitch. Drift and preamplifier gaps are formed by grid electrodes made of wire 50 μm in diameter with dimension of the cell equal to 1x1 mm. Width of the drift gap is 5 mm, width of the preamplification gap is 3 or 9 mm. Coordinate data are removed from the cathodes of the proportional chamber by means of delay lines. Sensitive square of the chamber equals 240x180 mm. Gas gain coefficient is 3x10 6 at its square nonuniformity equal to approximately 3%. Spatial resolution by both coordinates equals 170 μm; spatial resolution for isotropic α-emitters located close to the preamplifier gap is equal to 500 μm

  18. Weak coupling chambers in N=2 BPS quiver theory

    Energy Technology Data Exchange (ETDEWEB)

    Saidi, El Hassan, E-mail: h-saidi@fsr.ac.ma [Lab of High Energy Physics, Modeling and Simulations, Faculty of Science, University Mohammed V-Agdal, 4 Avenue Ibn Battota, Rabat (Morocco); Centre of Physics and Mathematics, CPM-CNESTEN, Rabat (Morocco)

    2012-11-01

    Using recent results on BPS quiver theory, we develop a group theoretical method to describe the quiver mutations encoding the quantum mechanical duality relating the spectra of distinct quivers. We illustrate the method by computing the BPS spectrum of the infinite weak chamber of some examples of N=2 supersymmetric gauge models without and with quark hypermultiplets.

  19. Use of gas mixture electroluminescence for optical data readout from wire chambers

    International Nuclear Information System (INIS)

    Polyakov, V.A.; Rykalin, V.I.; Tskhadadze, Eh.G.

    1988-01-01

    The radiation spectra, the values of electroluminescence yield and coefficients of gas amplification of Ar and Ne mixture with inorganic and organic additions in a wire chamber operating under proportional and self-quenching streamer conditions are measured. Maximum light yield: 2x10 7 photons for Ar+acetone+white spirit gas mixture in a proportional regime and 1.1x10 7 photons for Ar+CO 2 + ethyl alcohol+ white spirit in self-quenching streamer regime is obtained. Three methods of optical data readout from the wire chambers are tested. The best results are obtained when spectrum shifting bands and fibers are placed behind the chamber cathode planes

  20. Short-term variation in ocular anterior chamber angle using Scheimpflug photography

    OpenAIRE

    A. Rubin

    2010-01-01

    Purpose: To investigate short-term variation of ocular Anterior Chamber Angle (ACA) within and across the different meridians of young, healthy eyes. Method: Scheimpflug photography (via an  Oculus Pentacam) was used to repeatedly measure the anterior segment of the right eyes of three young females, all aged 22 years.  For each individual, ten consecutive maps were determined over a short time period and each map contained information for the chamber angles of different meridians acr...

  1. More realistic simulation of the response of an ionization chamber

    International Nuclear Information System (INIS)

    Torii, T.; Nozaki, T.; Ando, H.

    1994-01-01

    In order to study the consequence of geometrical modeling of a finger tip ionization chamber and the difference of the calculated results using two Monte Carlo codes EGS4 and ITS3.0, the energy responses of an ionization chamber have been calculated. In the EGS4 calculation, it has been developed a versatile user code PRESTA-CG to calculate the response of radiation detectors with more complicated geometrical design by the combinatorial geometry (CG) method. This paper presents comparisons of the energy responses between these codes. (author)

  2. Industrial development of neutron detectors, fission chambers, self powered detectors, ionization chambers

    International Nuclear Information System (INIS)

    Constans, H.; Coville, P.; Guerre, J.

    1975-01-01

    Reactor control requires the determination of neutron flux at all times. The needed characteristics lead to use of several types of detectors: boron lined counters, boron lined ionization chambers, fission ionization chambers and self powered detectors. The principle of the reaction involved the fabrication requirements, the different modes of utilization and the characteristics obtained are examined for each detector. The problem of electric connections in the active area has been solved by developing ''integrated cables'' [fr

  3. The little holographic bubble chambers

    International Nuclear Information System (INIS)

    Herve, A.

    1983-01-01

    The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr

  4. Pelletron general purpose scattering chamber

    International Nuclear Information System (INIS)

    Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh

    1993-01-01

    A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs

  5. Temperature changes in the pulp chamber during dentin ablation with Er:YAG laser

    Science.gov (United States)

    Zhang, Xianzeng; Zhao, Haibin; Zhan, Zhenlin; Guo, Wenqing; Xie, Shusen

    2012-12-01

    To examine the temperature changes in the pulp chamber during cavity preparation in dentin with the Er:YAG laser (2940 nm), a total 20 intact premolars teeth were divided into 4 groups for dentin ablation with different radiant exposures at 4Hz and 8Hz with and without water spray. A K-type thermocouple was used to monitor the temperature changes in pulp chamber during laser treatment. The total time of irradiation was 70 sec. the water spray rate was 3 mL/min. It showed that maximum temperature rise increases with the increasing of radiant exposure and pulse repetition rate and the additional water cooling during laser ablation can significantly reduce the temperature rise in pulp chamber which will benefit to avoid or reduce thermal damage to tooth structure and dental pulp. The highest rise of temperature in the pulp was achieved with 20 J/cm2 and 8 Hz (19.83°C ). For all sample without water spray, the rise of temperature was exceed 5 °C . In contrast, with water spray, the temperature rise in the pulp can be firmly controlled under 1°C. The results also indicated that ablation rate and efficiency can be enhanced by increasing the incident radiant exposure and pulse repetition rate, which simultaneously producing more heat accumulation in dental tissue and causing thermal damage to dental tissue. By applying an additional water spray, thermal damage can be significantly reduced in clinical application.

  6. Radon diffusion chamber

    International Nuclear Information System (INIS)

    Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.

    1986-01-01

    The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4

  7. Multispecimen dual-beam irradiation damage chamber

    International Nuclear Information System (INIS)

    Packan, N.H.; Buhl, R.A.

    1980-06-01

    An irradiation damage chamber that can be used to rapidly simulate fast neutron damage in fission or fusion materials has been designed and constructed. The chamber operates in conjunction with dual Van de Graaff accelerators at ORNL to simulate a wide range of irradiation conditions, including pulsed irradiation. Up to six experiments, each with up to nine 3-mm disk specimens, can be loaded into the ultrahigh vacuum chamber. Specimen holders are heated with individual electron guns, and the temperature of each specimen can be monitored during bombardment by an infrared pyrometer. Three different dose levels may be obtained during any single bombardment, and the heavy-ion flux on each of the nine specimens can be measured independently with only a brief interruption of the beam. The chamber has been in service for nearly three years, during which time approximately 250 bombardments have been successfully carried out. An appendix contains detailed procedures for operating the chamber

  8. Bi-cone vacuum chamber in the ISR

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The "bi-cone" vacuum chamber in ISR intersection I-7, for experiment R702. Made from 0.28 mm thick titanium, it was at its time the most transparent chamber ever built. Ian Wilson is standing next to the chamber. See also 7609219.

  9. Device for gamma-chamber transducer alignment

    International Nuclear Information System (INIS)

    Mirkhodzhaev, A.Kh.; Kuznetsov, N.K.; Ostryj, Yu.E.

    1987-01-01

    The device consists of the upper part of the gamma chamber pilar to which a rod is rigidly fastened with a disk of acrylic plastic moving freely on the opposite end. The disk is placed coaxially and is equal to the gamma chamber detector crystal. The device makes it possible to use ordinary medical couches covered with a porolone mattress when the gamma chamber detector is placed below

  10. Bubble chamber: Omega production and decay

    CERN Document Server

    1973-01-01

    This image is taken from one of CERN's bubble chambers and shows the decay of a positive kaon in flight. The decay products of this kaon can be seen spiraling in the magnetic field of the chamber. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that has been heated to boiling point.

  11. Venturi vacuum systems for hypobaric chamber operations.

    Science.gov (United States)

    Robinson, R; Swaby, G; Sutton, T; Fife, C; Powell, M; Butler, B D

    1997-11-01

    Physiological studies of the effects of high altitude on man often require the use of a hypobaric chamber to simulate the reduced ambient pressures. Typical "altitude" chambers in use today require complex mechanical vacuum systems to evacuate the chamber air, either directly or via reservoir system. Use of these pumps adds to the cost of both chamber procurement and maintenance, and service of these pumps requires trained support personnel and regular upkeep. In this report we describe use of venturi vacuum pumps to perform the function of mechanical vacuum pumps for human and experimental altitude chamber operations. Advantages of the venturi pumps include their relatively low procurement cost, small size and light weight, ease of installation and plumbing, lack of moving parts, and independence from electrical power sources, fossil fuels and lubricants. Conversion of three hyperbaric chambers to combined hyper/hypobaric use is described.

  12. CONVECTIVE HEAT EXCHANGE ON THE LATERAL SURFACE OF A RELATIVELY LONG CYCLONE CHAMBER

    Directory of Open Access Journals (Sweden)

    E. N. Saburov

    2016-01-01

    Full Text Available The high-turbulent swirling flows of heat carrier that are created by a cyclone chamber are used in industry. They make it possible to intensify processes of heat and mass exchange. The results of an experimental study of convective heat transfer on the lateral surface of the active volume of a relatively long cyclone chamber considerably exceeding the length of the chambers that were used in previously performed studies are presented and analyzed in the article. Air supply in the swirler of the chamber was performed tangentially from diametrically opposite sides of the two input channels. The gas outlet was implemented from the opposite end. The heat transfer by convection to the swirling air flow was studied by the method of changing the state of aggregation of a heating agent – condensation of slightly superheated steam. Collecting condensate from the working section was made through a water seal for maintaining a constant pressure calorimeter. The amount of heat transferred during experiment was determined by weight of the collected condensate. The specific features of influence of geometrical characteristics of cyclone chamber on intensity of heat exchange are considered. In the experiments we varied the relative diameter of the outlet port of the chamber dвых and the relative area of the input channels fвх. Segmental construction of the chamber made it possible to move a calorimeter on its length. The local heat transfer coefficient was determined for various values of the dimensionless longitudinal coordinate z coinciding with the axis of the chamber, and counted from the back end of the swirler. The estimated equations of heat transfer obtained during the research are presented and recommended for use in practice of engineering. The considered problem is of an interest from the point of view of further research of aerodynamics and of convective heat transfer in a highly swirling flow cyclone devices, in order to improve the

  13. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    Energy Technology Data Exchange (ETDEWEB)

    Diener, R.

    2006-12-15

    A new e{sup +}e{sup -} linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  14. Study of reconstruction methods for a time projection chamber with GEM gas amplification system

    International Nuclear Information System (INIS)

    Diener, R.

    2006-12-01

    A new e + e - linear collider with an energy range up to 1TeV is planned in an international collaboration: the International Linear Collider (ILC). This collider will be able to do precision measurements of the Higgs particle and of physics beyond the Standard Model. In the Large Detector Concept (LDC) - which is one proposal for a detector at the ILC - a Time Projection Chamber (TPC) is foreseen as the main tracking device. To meet the requirements on the resolution and to be able to work in the environment at the ILC, the application of new gas amplification technologies in the TPC is necessary. One option is an amplification system based on Gas Electron Multipliers (GEMs). Due to the - in comparison with older technologies - small spatial width of the signals, this technology poses new requirements on the readout structures and the reconstruction methods. In this work, the performance and the systematics of different reconstruction methods have been studied, based on data measured with a TPC prototype in high magnetic fields of up to 4T and data from a Monte Carlo simulation. The latest results of the achievable point resolution are presented and their limitations have been investigated. (orig.)

  15. Note: A single-chamber tool for plasma activation and surface functionalization in microfabrication

    Energy Technology Data Exchange (ETDEWEB)

    Bowman, Adam J.; Scherrer, Joseph R.; Reiserer, Ronald S., E-mail: ron.reiserer@vanderbilt.edu [Vanderbilt Institute for Integrative Biosystems Research and Education and Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee 37235 (United States)

    2015-06-15

    We present a simple apparatus for improved surface modification of polydimethylsiloxane (PDMS) microfluidic devices. A single treatment chamber for plasma activation and chemical/physical vapor deposition steps minimizes the time-dependent degradation of surface activation that is inherent in multi-chamber techniques. Contamination and deposition irregularities are also minimized by conducting plasma activation and treatment phases in the same vacuum environment. An inductively coupled plasma driver allows for interchangeable treatment chambers. Atomic force microscopy confirms that silane deposition on PDMS gives much better surface quality than standard deposition methods, which yield a higher local roughness and pronounced irregularities in the surface.

  16. An open-flow pulse ionization chamber for alpha spectrometry of large-area samples

    International Nuclear Information System (INIS)

    Johansson, L.; Roos, B.; Samuelsson, C.

    1992-01-01

    The presented open-flow pulse ionization chamber was developed to make alpha spectrometry on large-area surfaces easy. One side of the chamber is left open, where the sample is to be placed. The sample acts as a chamber wall and therby defeins the detector volume. The sample area can be as large as 400 cm 2 . To prevent air from entering the volume there is a constant gas flow through the detector, coming in at the bottom of the chamber and leaking at the sides of the sample. The method results in good energy resolution and has considerable applicability in the retrospective radon research. Alpha spectra obtained in the retrospective measurements descend from 210 Po, built up in the sample from the radon daughters recoiled into a glass surface. (au)

  17. XTR detection by means of 20 μm resolution drift chamber

    International Nuclear Information System (INIS)

    Baskakov, V.I.; Dolgoshein, B.A.; Lebedenko, V.N.

    1977-01-01

    The possibility to separate spatially the ionization losses of a relativistic charged particle and XTR quanta generated by the same particle in the laminated medium in detector was investigated. A double electroluminescent drift chamber filled with xenon at 10 atm pressure was constructed for this purpose. A detailed examination of the chamber characteristics was carried out on 3.5 GeV energy electron beam. The obtained results demonstrated the possibility to separate XTR and particle ionization spatially by means of the described method

  18. Apparatus for reading and recharging condenser ionization chambers

    International Nuclear Information System (INIS)

    McCall, R.C.

    1977-01-01

    A metering circuit for a condenser ionization chamber is disclosed for simultaneously recharging the ionization chamber and reading out the amount of charge required to recharge the chamber. During the recharging process, the amount of charge necessary to recharge the ionization chamber capacitor is placed on an integrating capacitor in the metering apparatus. The resultant voltage across the integrating capacitor is a measure of the radiation to which the ionization chamber was exposed. 9 claims, 1 figure

  19. Liquid-filled ionization chamber temperature dependence

    Energy Technology Data Exchange (ETDEWEB)

    Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)

    2006-05-10

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  20. On the possibility of obtaining non-diffused proximity functions from cloud-chamber data: Pt. 2

    International Nuclear Information System (INIS)

    Zaider, M.

    1988-01-01

    Maximum entropy and Bayesian methods are applied to an inversion problem which consists of unfolding diffusion from proximity functions calculated from cloud-chamber data. The solution appears to be relatively insensitive to statistical errors in the data (an important feature) given the limited number of tracks normally available from cloud-chamber measurements. It is the first time, to our knowledge, that such methods are applied to microdosimetry. (author)

  1. Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Bulla, Roseli Tadeu

    1999-07-01

    The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

  2. Bubble chamber: antiproton annihilation

    CERN Multimedia

    1971-01-01

    These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  3. Calibration of PKA meters against ion chambers of two geometries

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Pereira, Marco A.G.; Herdade, Silvio B.

    2011-01-01

    Kerma-area product (KAP or PKA) is a quantity that is independent of the distance to the X-ray tube focal spot and that can be used in radiological exams to assess the effective dose in patients. Clinical KAP meters are generally fixed in tube output and they are usually calibrated on-site by measuring the air kerma with an ion chamber and by evaluating the irradiated area by means of a radiographic image. Recently, a device was marketed (PDC, Patient Dose Calibrator, Radcal Co.), which was designed for calibrating clinical KAP meters with traceability to a standard laboratory. This paper presents a metrological evaluation of two methods that can be used in standard laboratories for the calibration of this device, namely, against a reference 30 cc ionization chamber or a reference parallel plates monitor chamber. Lower energy dependence was also obtained when the PDC calibration was made with the monitor chamber. Results are also shown of applying the PDC in hospital environment to the cross calibration of a clinical KAP meter from a radiology equipment. Results confirm lower energy dependence of the PDC relatively to the tested clinical meter. (author)

  4. Temperature Studies for ATLAS MDT BOS Chambers

    CERN Document Server

    Engl, A.; Biebel, O.; Mameghani, R.; Merkl, D.; Rauscher, F.; Schaile, D.; Ströhmer, R.

    Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber ...

  5. Casting methods

    Science.gov (United States)

    Marsden, Kenneth C.; Meyer, Mitchell K.; Grover, Blair K.; Fielding, Randall S.; Wolfensberger, Billy W.

    2012-12-18

    A casting device includes a covered crucible having a top opening and a bottom orifice, a lid covering the top opening, a stopper rod sealing the bottom orifice, and a reusable mold having at least one chamber, a top end of the chamber being open to and positioned below the bottom orifice and a vacuum tap into the chamber being below the top end of the chamber. A casting method includes charging a crucible with a solid material and covering the crucible, heating the crucible, melting the material, evacuating a chamber of a mold to less than 1 atm absolute through a vacuum tap into the chamber, draining the melted material into the evacuated chamber, solidifying the material in the chamber, and removing the solidified material from the chamber without damaging the chamber.

  6. A closed-chamber method to measure greenhouse gas fluxes from dry aquatic sediments

    Science.gov (United States)

    Lesmeister, Lukas; Koschorreck, Matthias

    2017-06-01

    Recent research indicates that greenhouse gas (GHG) emissions from dry aquatic sediments are a relevant process in the freshwater carbon cycle. However, fluxes are difficult to measure because of the often rocky substrate and the dynamic nature of the habitat. Here we tested the performance of different materials to seal a closed chamber to stony ground both in laboratory and field experiments. Using on-site material consistently resulted in elevated fluxes. The artefact was caused both by outgassing of the material and production of gas. The magnitude of the artefact was site dependent - the measured CO2 flux increased between 10 and 208 %. Errors due to incomplete sealing proved to be more severe than errors due to non-inert sealing material.Pottery clay as sealing material provided a tight seal between the chamber and the ground and no production of gases was detected. With this approach it is possible to get reliable gas fluxes from hard-substrate sites without using a permanent collar. Our test experiments confirmed that CO2 fluxes from dry aquatic sediments are similar to CO2 fluxes from terrestrial soils.

  7. A closed-chamber method to measure greenhouse gas fluxes from dry aquatic sediments

    Directory of Open Access Journals (Sweden)

    L. Lesmeister

    2017-06-01

    Full Text Available Recent research indicates that greenhouse gas (GHG emissions from dry aquatic sediments are a relevant process in the freshwater carbon cycle. However, fluxes are difficult to measure because of the often rocky substrate and the dynamic nature of the habitat. Here we tested the performance of different materials to seal a closed chamber to stony ground both in laboratory and field experiments. Using on-site material consistently resulted in elevated fluxes. The artefact was caused both by outgassing of the material and production of gas. The magnitude of the artefact was site dependent – the measured CO2 flux increased between 10 and 208 %. Errors due to incomplete sealing proved to be more severe than errors due to non-inert sealing material.Pottery clay as sealing material provided a tight seal between the chamber and the ground and no production of gases was detected. With this approach it is possible to get reliable gas fluxes from hard-substrate sites without using a permanent collar. Our test experiments confirmed that CO2 fluxes from dry aquatic sediments are similar to CO2 fluxes from terrestrial soils.

  8. Brookhaven National Laboratory's multiparticle spectrometer drift chamber system

    International Nuclear Information System (INIS)

    Etkin, A.; Kramer, M.A.

    1979-01-01

    A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties

  9. Open-air ionisation chambers with walls of soft-tissue equivalent material for measuring photon doses

    International Nuclear Information System (INIS)

    Vialettes, H.; Anceau, J.C.; Grand, M.; Petit, G.

    1968-01-01

    The ionisation chambers presented in this report constitute a contribution to research into methods of carrying out correct determinations in the field of health physics. The use of a mixture of teflon containing 42.5 per cent by weight of carbon for the chamber walls makes it possible to measure directly the dose absorbed in air through 300 mg/cm 2 of soft tissue and, consequently, the dose absorbed in the soft tissues with a maximum error of 10 per cent for photon energies of between 10 keV and 10 MeV. Furthermore since this material does not contain hydrogen, the chamber has a sensitivity to neutrons which is much less than other chambers in current use. Finally the shape of these chambers has been studied with a view to obtaining a satisfactory measurement from the isotropy point of view; for example for gamma radiation of 27 keV, the 3 litre chamber is isotropic to within 10 per cent over 270 degrees, and the 12 litre chamber is isotropic to within 10 per cent over 300 degrees; for 1.25 MeV gamma radiation this range is extended over 330 degrees for the 3 litre chamber, and 360 degrees for the 12 litre chamber. This report presents the measurements carried out with these chambers as well as the results obtained. These results are then compared to those obtained with other chambers currently used in the field of health physics. (authors) [fr

  10. LEP vacuum chamber, cross-section

    CERN Multimedia

    CERN PhotoLab

    1983-01-01

    Cross-section of the final prototype for the LEP vacuum chamber. The elliptic main-opening is for the beam. The small channel to the left is for the cooling water, to carry away the heat deposited by the synchrotron radiation. The square channel to the right houses the Non-Evaporable Getter (NEG) pump. The chamber is made from extruded aluminium. Its outside is clad with lead, to stop the synchrotron radiation emitted by the beam. For good adherence between Pb and Al, the Al chamber was coated with a thin layer of Ni. Ni being slightly magnetic, some resulting problems had to be overcome. See also 8301153.

  11. Hong's grading for evaluating anterior chamber angle width.

    Science.gov (United States)

    Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul

    2012-11-01

    To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

  12. Note: Small anaerobic chamber for optical spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chauvet, Adrien A. P., E-mail: adrien.chauvet@gmail.com; Chergui, Majed [Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratoire de Spectroscopie Ultrarapide, ISIC, Faculté des Sciences de Base, Station 6, 1015 Lausanne (Switzerland); Agarwal, Rachna; Cramer, William A. [Department of Biological Sciences, Purdue University, West Lafayette, Indiana 47907 (United States)

    2015-10-15

    The study of oxygen-sensitive biological samples requires an effective control of the atmosphere in which they are housed. In this aim however, no commercial anaerobic chamber is adequate to solely enclose the sample and small enough to fit in a compact spectroscopic system with which analysis can be performed. Furthermore, spectroscopic analysis requires the probe beam to pass through the whole chamber, introducing a requirement for adequate windows. In response to these challenges, we present a 1 l anaerobic chamber that is suitable for broad-band spectroscopic analysis. This chamber has the advantage of (1) providing access, via a septum, to the sample and (2) allows the sample position to be adjusted while keeping the chamber fixed and hermetic during the experiment.

  13. Structural Analysis of Extended Plasma Focus Chamber

    International Nuclear Information System (INIS)

    Mohd Azhar Ahmad; Abdul Halim Baijan; Siti Aiasah Hashim

    2016-01-01

    Accelerator Development Centre (ADC) of Nuclear Malaysia intends to upgrade the plasma focus device. It involves the extension part placed on top of the existing plasma focus vacuum chamber. This extended vacuum chamber purposely to give an extra space in conducting experiments on the existing plasma focus chamber. The aim of upgrading the plasma focus device is to solve the limitation in research and analysis of sample due to its done in an open system that cause analysis of samples is limited and less optimal. This extended chamber was design in considering the ease of fabrication as well as durability of its structural. Thus, this paper discusses the structural analysis in term of pressure loading effect in extended chamber. (author)

  14. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  15. Accumulation of cesium-137 and strontium-90 in ponderosa pine and monterey pine seedlings

    International Nuclear Information System (INIS)

    Entry, J.A.; Rygiewicz, P.T.; Emmingham, W.H.

    1993-01-01

    Because ponderosa pine Pinus ponderosa and Monterey pone (P. radiata D Don) have exceptionally fast growth rates and their abscised needles are not readily dispersed by wind, these species may be valuable for removing radioisotopes from contaminated soils. Ponderosa and Monterey pine seedlings were tested for their ability to accumulate 137 Cs and 90 Sr-characteristic radioisotopes of nuclear fallout-from contaminated soil. Seedlings were grown for 3 mo in 165 cm 3 sphagnum peat moss/perlite (1:1 V/V) in a growth chamber. In Exp. 1, seedling accumulation of 137 Cs and 90 Sr after 1 mo of exposure was measured. In Exp. 2, seedling accumulation of the radioisotopes during different-length exposures was measured. Seedling accumulation of 137 CS and 90 Sr at different concentrations of the radioisotopes in the growth medium was measured in Exp. 3. Ponderosa pine accumulated 6.3% of the 137 Cs and I.5% of the 90 Sr present in the growth medium after 1 mo; Monterey pine accumulated 8.3% of the 137 Cs and 4.5% of the 90 Sr. Accumulation of 137 Cs and 90 Sr by both coniferous species was curvilinearly related to duration of exposure. Accumulation of 137 Cs and 90 Sr by both species increased with increasing concentration in the growth medium and correlated curvilinearly with radioisotope concentration in the growth medium. Large areas throughout the world are contaminated with 137 Cs and 90 Sr as a result of nuclear weapons testing or atomic reactor accidents. The ability of trees to sequester and store 137 Cs and 90 Sr introduces the possibility of using reforestation to remediate contaminated soils

  16. Chamber wall response to target implosion in inertial fusion reactors: new and critical assessments

    International Nuclear Information System (INIS)

    Hassanein, A.; Morozov, V.

    2002-01-01

    The chamber walls in inertial fusion energy (IFE) reactors are exposed to harsh conditions following each target implosion. Key issues of the cyclic IFE operation include intense photon and ion deposition, wall thermal and hydrodynamic evolution, wall erosion and fatigue lifetime, and chamber clearing and evacuation to ensure desirable conditions prior to next target implosion. Several methods for wall protection have been proposed in the past, each having its own advantages and disadvantages. These methods include use of solid bare walls, gas-filled cavities, and liquid walls/jets. Detailed models have been developed for reflected laser light, emitted photons, and target debris deposition and interaction with chamber components and have been implemented in the comprehensive HEIGHTS software package. The focus of this study is to critically assess the reliability and the dynamic response of chamber walls in IFE systems. Of particular concern is the effect on wall erosion lifetime due to various erosion mechanisms, such as vaporization, chemical and physical sputtering, melt/liquid splashing and explosive erosion, and fragmentation of liquid walls

  17. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  18. Drift chamber vertex detectors for SLC/LEP

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, K G

    1988-03-01

    Factors influencing the design of drift chamber vertex detectors for SLC and LEP are discussed including global strategy, chamber gas, cell design, and signal processing. The designs of the vertex chambers for the L3 and OPAL experiments at LEP and the Mark II experiment at the SLC are described.

  19. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  20. Nuclear design considerations for Z-IFE chambers

    Energy Technology Data Exchange (ETDEWEB)

    Meier, W.R. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)]. E-mail: meier5@llnl.gov; Schmitt, R.C. [Bettis Atomic Power Laboratory, Pittsburgh, PA 15203 (United States); Abbott, R.P. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Latkowski, J.F. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Reyes, S. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)

    2006-02-15

    Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets ({approx}2-3 GJ/shot), low repetition rate per chamber ({approx}0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (X-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped recyclable transmission line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here.

  1. Determination of dose components in mixed gamma neutron fields by use of high pressure ionization chambers

    International Nuclear Information System (INIS)

    Golnik, N.; Pliszczynski, T.; Wysocka, A.; Zielczynski, M.

    1985-01-01

    The two ionization chamber method for determination of dose components in mixed γ-neutron field has been improved by increasing gas pressure in the chambers up to some milions pascals. Advantages of high pressure gas filling are the followings: 1) significant reduction of the ratio of neutron-to gamma sensitivity for the hydrogen-free chamber, 2) possibility of sensitivity correction for both chambers by application of appropriate voltage, 3) high sensitivity for small detectors. High-pressure, pen-like ionization chambers have been examined in fields of different neutron sources: a TE-chamber, filled with 0.2 MPa of quasi-TE-gas and a conductive PTFE chamber, filled with 3.1 MPa of CO 2 . The ratio of neutron-to-gamma sensitivity for the PTFE chamber, operated at electrical field strength below 100 V/cm, has not exceeded 0.01 for neutrons with energy below 8 MeV. Formula is presented for calculation of this ratio for any high-pressure, CO 2 -filled ionization chamber. Contribution of gamma component to total tissue dose in the field of typical neutron sources has been found to be 3 to 70%

  2. A proposed simple method for measurement in the anterior chamber angle: biometric gonioscopy.

    Science.gov (United States)

    Congdon, N G; Spaeth, G L; Augsburger, J; Klancnik, J; Patel, K; Hunter, D G

    1999-11-01

    To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest. Clinic-based validation and interobserver reliability trial. Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic. In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK). Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy. In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient

  3. Bicarbonate trigger for inducing lipid accumulation in algal systems

    Science.gov (United States)

    Gardner, Robert; Peyton, Brent; Cooksey, Keith E.

    2015-08-04

    The present invention provides bicarbonate containing and/or bicarbonate-producing compositions and methods to induce lipid accumulation in an algae growth system, wherein the algae growth system is under light-dark cycling condition. By adding said compositions at a specific growth stage, said methods lead to much higher lipid accumulation and/or significantly reduced total time required for accumulating lipid in the algae growth system.

  4. "Flat-Fish" Vacuum Chamber

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.

  5. Improved climatic chamber for desiccation simulation

    Directory of Open Access Journals (Sweden)

    Lozada Catalina

    2016-01-01

    Full Text Available The climatic chamber at the Universidad de Los Andes was improved for modeling desiccation in soil layers. This chamber allows the measurement of different environmental variables. In this research, evaporation tests were conducted in water imposing boundary conditions for drying, and then these tests were performed in a soil layer. The soil was prepared from a slurry state and was drying controlling the temperature, the infrared radiation, the wind velocity, and the relative humidity. In the first part of this paper, a description of the climatic chamber, operation ranges and theoretical work principles of the climatic chamber are presented. Then, the second part shows the results for desiccation in water and soil. The desiccation tests performed with the climatic chamber allow simulating all environmental conditions accurately during drying coupling the effect of all environmental variables. As a result, the evaporation rate increases with infrared radiation in soil and water. The rate at the beginning of the desiccation tests in clays is the same as in water. However, this evaporation rate decreases as the soil becomes desiccated.

  6. RESULTS OF THE DIESEL COMBUSTION CHAMBER OPTIMIZED DESIGN IN THE MULTICRITERIAL TASK ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    A. Wrublewski

    2015-12-01

    Full Text Available The results of optimized designing of the higi-speed vehicle diesel engine combustion chamber based on application of the method of parameters space investingation are given. The optimal form of the combustion chamber and the direction of fuel jets at adjusted pressure rate and other functional resrictions are determined according to three criteria of quality – fuel consumption, hard particles and nitric oxide emissions.

  7. The Stiffness and Damping Characteristics of a Dual-Chamber Air Spring Device Applied to Motion Suppression of Marine Structures

    Directory of Open Access Journals (Sweden)

    Xiaohui Zeng

    2016-03-01

    Full Text Available Dual-chamber air springs are used as a key component for vibration isolation in some industrial applications. The working principle of the dual-chamber air spring device as applied to motion suppression of marine structures is similar to that of the traditional air spring, but they differ in their specific characteristics. The stiffness and damping of the dual-chamber air spring device determine the extent of motion suppression. In this article, we investigate the stiffness and damping characteristics of a dual-chamber air spring device applied to marine structure motion suppression using orthogonal analysis and an experimental method. We measure the effects of volume ratio, orifice ratio, excitation amplitude, and frequency on the stiffness and damping of the dual-chamber vibration absorber. Based on the experimental results, a higher-order non-linear regression method is obtained. We achieve a rapid calculation model for dual-chamber air spring stiffness and damping, which can provide guidance to project design.

  8. The Bern Infinitesimal Bubble Chamber (BIBC)

    CERN Multimedia

    CERN PhotoLab

    1977-01-01

    The chamber body was machined from a block of aluminium. The visible volume was cylindrical with 65 mm diameter and 35 mm depth. It was filled with propane or freon. It was meant as vertex detector in the search of short-lived particles. It was also used with in-line holography resulting in 8 µm bubble size and 9 cm depth of the field. See E. Ramseyer, B. Hahn and E. Hugentobler, Nucl. Instrum. Methods 201 (1982) 335.

  9. Mixed field dosimetry with the twin chamber technique

    International Nuclear Information System (INIS)

    Burger, G.; Maier, E.

    1974-04-01

    For the separate dosimetry of the neutron- and gamma-component in a mixed beam it is principally possible to use two ionization chambers with different ratios of neutron- to gamma sensitivity. Several authors proposed for this purpose the use of a homogenious TE-chamber filled with the TE-gas and of a carbon-chamber filled with CO 2 -gas. This chamber combination is also commercially available in several countries. The chambers are normally equipped with a continuous gas-flow provision and with a waterproof-housing for the use within liquid phantoms. The application of such chambers for mixed field dosimetry in the intercomparison project of the ICRU at the RARAF-facility in Brookhaven (International Neutron Dosimetry Intercomparison - INDI) is described. (orig./HP) [de

  10. Drift chamber tracking with neural networks

    International Nuclear Information System (INIS)

    Lindsey, C.S.; Denby, B.; Haggerty, H.

    1992-10-01

    We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed

  11. Development of an environmental chamber for evaluating the performance of low-cost air quality sensors under controlled conditions

    Science.gov (United States)

    Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea

    2017-12-01

    A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.

  12. New Submersed Chamber for Calibration of Relative Humidity Instruments at HMI/FSB-LPM

    Science.gov (United States)

    Sestan, D.; Zvizdic, D.; Sariri, K.

    2018-02-01

    This paper gives a detailed description of a new chamber designed for calibration of relative humidity (RH) instruments at Laboratory for Process Measurement (HMI/FSB-LPM). To the present time, the calibrations of RH instruments at the HMI/FSB-LPM were done by comparison method using a climatic chamber of large volume and calibrated dew point hygrometer with an additional thermometer. Since 2010, HMI/FSB-LPM in cooperation with Centre for Metrology and Accreditation in Finland (MIKES) developed the two primary dew point generators which cover the dew point temperature range between - 70 {°}C and 60 {°}C. In order to utilize these facilities for calibrations of the RH instruments, the new chamber was designed, manufactured and installed in the existing system, aiming to extend its range and reduce the related calibration uncertainties. The chamber construction allows its use in a thermostatic bath of larger volume as well as in the climatic chambers. In the scope of this paper, performances of the new chamber were tested while it was submersed in a thermostated bath. The chamber can simultaneously accommodate up to three RH sensors. In order to keep the design of the chamber simple, only cylindrical RH sensors detachable from display units can be calibrated. Possible optimizations are also discussed, and improvements in the design proposed. By using the new chamber, HMI/FSB-LPM reduced the expanded calibration uncertainties (level of confidence 95 %, coverage factor k=2) from 0.6 %rh to 0.25 %rh at 30 %rh (23 {°}C), and from 0.8 %rh to 0.53 %rh at 70 %rh (23 {°}C).

  13. Determination of absorbed dose calibration factors for therapy level electron beam ionization chambers.

    Science.gov (United States)

    McEwen, M R; Williams, A J; DuSautoy, A R

    2001-03-01

    Over several years the National Physical Laboratory (NPL) has been developing an absorbed dose calibration service for electron beam radiotherapy. To test this service, a number of trial calibrations of therapy level electron beam ionization chambers have been carried out during the last 3 years. These trials involved 17 UK radiotherapy centres supplying a total of 46 chambers of the NACP, Markus, Roos and Farmer types. Calibration factors were derived from the primary standard calorimeter at seven energies in the range 4 to 19 MeV with an estimated uncertainty of +/-1.5% at the 95% confidence level. Investigations were also carried out into chamber perturbation, polarity effects, ion recombination and repeatability of the calibration process. The instruments were returned to the radiotherapy centres for measurements to be carried out comparing the NPL direct calibration with the 1996 IPEMB air kerma based Code of Practice. It was found that, in general, all chambers of a particular type showed the same energy response. However, it was found that polarity and recombination corrections were quite variable for Markus chambers-differences in the polarity correction of up to 1% were seen. Perturbation corrections were obtained and were found to agree well with the standard data used in the IPEMB Code. The results of the comparison between the NPL calibration and IPEMB Code show agreement between the two methods at the +/-1% level for the NACP and Farmer chambers, but there is a significant difference for the Markus chambers of around 2%. This difference between chamber types is most likely to be due to the design of the Markus chamber.

  14. Making MUSIC: A multiple sampling ionization chamber

    International Nuclear Information System (INIS)

    Shumard, B.; Henderson, D.J.; Rehm, K.E.; Tang, X.D.

    2007-01-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction

  15. Making MUSIC: A multiple sampling ionization chamber

    Science.gov (United States)

    Shumard, B.; Henderson, D. J.; Rehm, K. E.; Tang, X. D.

    2007-08-01

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. × 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction.

  16. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  17. Simple Cloud Chambers Using Gel Ice Packs

    Science.gov (United States)

    Kamata, Masahiro; Kubota, Miki

    2012-01-01

    Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…

  18. An experimental propane bubble chamber

    International Nuclear Information System (INIS)

    Rogozinski, A.

    1957-01-01

    Describes a propane bubble chamber 10 cm in diameter and 5 cm deep. The body of the chamber is in stainless steel, and it has two windows of polished hardened glass. The compression and decompression of the propane are performed either through a piston in direct contact with the liquid, or by the action on the liquid, through a triple-mylar-Perbunan membrane, of a compressed gas. The general and also optimum working conditions of the chamber are described, and a few results are given concerning, in particular, the tests of the breakage-resistance of the windows and the measurements of the thermal expansion of the compressibility isotherm for the propane employed. (author) [fr

  19. Very high intensity reaction chamber design

    International Nuclear Information System (INIS)

    Devaney, J.J.

    1975-09-01

    The problem of achieving very high intensity irradiation by light in minimal regions was studied. Three types of irradiation chamber are suggested: the common laser-reaction chamber, the folded concentric or near-concentric resonator, and the asymmetric confocal resonator. In all designs the ratio of high-intensity illuminated volume to other volume is highly dependent (to the 3 / 2 power) on the power and fluence tolerances of optical elements, primarily mirrors. Optimization of energy coupling is discussed for the common cavity. For the concentric cavities, optimization for both coherent and incoherent beams is treated. Formulae and numerical examples give the size of chambers, aspect ratios, maximum pass number, image sizes, fluences, and the like. Similarly for the asymmetric confocal chamber, formulae and numerical examples for fluences, dimensions, losses, and totally contained pass numbers are given

  20. DORIOT CLIMATIC CHAMBERS

    Data.gov (United States)

    Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...

  1. Sensitivity test of tumor cell to anticancer drug using diffusion chamber

    Energy Technology Data Exchange (ETDEWEB)

    Soejima, S [Hirosaki Univ., Aomori (Japan). School of Medicine

    1978-11-01

    The diffusion chamber method and xenogeneic transplantation of human cancer cells in rats were studied clinically to test the sensitivity of these cells to anticancer drugs. The growth of Hirosaki sarcoma in a diffusion chamber inserted in to Wistar rats was influenced by the difference in tumor cell counts in the chamber. The growth rate in the chamber inserted in to the subcutaneous tissue was more constant than in the abdominal cavity, but the degree of proliferation of tumor cells in the abdominal cavity was more than in the subcutaneous tissue. Sarcoma and solid type sarcoma were affected by mitomycin C (MMC). The effect was greater in dd-mice than in Donryu rats. Solid type Yoshida sarcoma inserted in to the subcutaneous tissue of Donryu rat was not affected by MMC. The degree of sensitivity of methylcholanthrene induced tumor cells, inserted in to the subcutaneous tissue of Donryu rats, to MMC differed according to various conditions of the hosts. Clinically, the influences of anticancer drugs on human cancer cells inserted in to the subcutaneous tissue of /sup 60/Co-irradiated Donryu rats were observed. There were various grades of sensitivity of gastric cancer cells to anticancer drugs. MMC was effective in 53% of the cases, Cyclophosphamide in 40%, 5-FU in 54%, cytosine arabinoside in 32%, and FT-207 in 57%. Twenty-seven percent were not affected by anticancer drugs. On histological examination, tubular adenocarcinoma cells had a high sensitivity to anticancer drugs, while poorly differentiated adenocarcinoma cells had a low sensitive. Anticancer drugs selected according to the sensitivity of human cancer cells had a marked effective on advanced cancer cells. The diffusion chamber method was useful in determining the degree of bone marrow toxicity of anticancer drugs.

  2. Practical electron dosimetry: a comparison of different types of ionization chambers

    International Nuclear Information System (INIS)

    Dohm, O.S.; Christ, G.

    2002-01-01

    Since Markus chambers are no longer recommended in the 1997 DIN 6800-2 version there are uncertainties as to the use of alternative chamber types for electron dosimetry. Therefore, we performed a comparison between different types of ionization chambers. In particular, the widespread Farmer and Roos chambers were compared with the Markus chamber for polarity effect, chamber-to-chamber variation, and deviations of the measured absorbed dose relative to the value obtained with the Roos chamber (which is regarded as an ideal Bragg-Gray-chamber). The perturbation correction factor at 60 Co radiation was determined experimentally as 1,029 ± 0,5% (Roos chamber) and 1,018 ± 0,5% (Markus chamber) for the investigated plane-parallel chambers. In addition, we could show that the Roos chambers do not have a larger chamber-to-chamber variation than the Farmer chambers. Likewise, our results suggest that Farmer chambers could be used for electron energies above 6 MeV. (orig.) [de

  3. Sensitivity of gaseous xenon ionisation chambers (1961)

    International Nuclear Information System (INIS)

    Schuhl, C.

    1960-01-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [fr

  4. Ionization chamber correction factors for MR-linacs.

    Science.gov (United States)

    Pojtinger, Stefan; Dohm, Oliver Steffen; Kapsch, Ralf-Peter; Thorwarth, Daniela

    2018-06-07

    Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B . The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0-2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.

  5. Ionization chamber correction factors for MR-linacs

    Science.gov (United States)

    Pojtinger, Stefan; Steffen Dohm, Oliver; Kapsch, Ralf-Peter; Thorwarth, Daniela

    2018-06-01

    Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0–2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.

  6. Quantifying and reducing the differences in forest CO2-fluxes estimated by eddy covariance, biometric and chamber methods: A global synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xingchang; Wang, Chuankuan; Bond-Lamberty, Benjamin

    2017-12-15

    Carbon dioxide (CO2) fluxes between terrestrial ecosystems and the atmosphere are primarily measured with eddy covariance (EC), biometric, and chamber methods. However, it is unclear why the estimates of CO2-fluxes, when measured using these different methods, converge at some sites but diverge at others. We synthesized a novel global dataset of forest CO2-fluxes to evaluate the consistency between EC and biometric or chamber methods for quantifying CO2 budget in forests. The EC approach, comparing with the other two methods, tended to produce 25% higher estimate of net ecosystem production (NEP, 0.52Mg C ha-1 yr-1), mainly resulting from lower EC-estimated Re; 10% lower ecosystem respiration (Re, 1.39Mg C ha-1 yr-1); and 3% lower gross primary production (0.48 Mg C ha-1 yr-1) The discrepancies between EC and the other methods were higher at sites with complex topography and dense canopies versus those with flat topography and open canopies. Forest age also influenced the discrepancy through the change of leaf area index. The open-path EC system induced >50% of the discrepancy in NEP, presumably due to its surface heating effect. These results provided strong evidence that EC produces biased estimates of NEP and Re in forest ecosystems. A global extrapolation suggested that the discrepancies in CO2 fluxes between methods were consistent with a global underestimation of Re, and overestimation of NEP, by the EC method. Accounting for these discrepancies would substantially improve the our estimates of the terrestrial carbon budget .

  7. Track resolution in the RPC chamber

    International Nuclear Information System (INIS)

    Cardarelli, R.; Aielli, G.; Camarri, P.; Di Ciaccio, A.; Liberti, B.; Santonico, R.

    2007-01-01

    A new very promising read out, in addition to the well-known charge centroid method, is proposed for improving the space resolution in the Resistive Plate Chamber (RPC) in the sub-millimeter range. The method is based on the read out of the signal propagating in the graphite electrode which was simulated using a distributed resistance-capacitance model in SPICE. The results show that a good space-time correlation in the diffusion process is only possible by suitable signal processing. Three RPC detectors with the new layout and dedicated electronics were tested. The measured space resolution was in the order of a few 100μm

  8. Pencil beam proton radiography using a multilayer ionization chamber

    NARCIS (Netherlands)

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-01-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (+/- 0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a

  9. Bubble chamber: Omega production and decay

    CERN Multimedia

    1973-01-01

    This image is of real particle tracks taken from the CERN 2 m liquid hydrogen bubble chamber and shows the production and decay of a negative omega particle. A negative kaon enters the chamber which decays into many particles, including a negative omega that travels a short distance before decaying into more particles. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.

  10. Evaluation of carbon dioxide dissipation within a euthanasia chamber.

    Science.gov (United States)

    Djoufack-Momo, Shelly M; Amparan, Ashlee A; Grunden, Beverly; Boivin, Gregory P-

    2014-07-01

    CO₂ euthanasia is used widely for small laboratory animals, such as rodents. A common necessity in many animal research facilities is to euthanize mice in sequential batches. We assessed the effects of several variables on the time it took for CO₂ to dissipate within a chamber. Using standard euthanasia time, changes in flow rate were compared between a slow 15% fill rate for 7 min, and a slow 15% followed by a rapid 50% filling for a total of 5 min. Additional variables assessed included the effects of opening the lid after the completion of chamber filling, turning the chamber over after completion of filling, and the use and removal of a cage from within the chamber. For all trials, CO₂ levels in the chambers peaked between 50% and 80%. After the gas was turned off, the concentration of CO₂ dropped to below 10% COv within 2 min, except when the lid was left on the chamber, where concentration levels remained above 10% after 20 min. CO₂ dissipation was significantly faster when the chamber was turned upside down after filling. Significant interaction effects occurred among the factors of cage presence within the chamber, flow rate, and chamber position. Only leaving the lid on the chamber had any practical implication for delaying CO₂ dissipation. We recommend that users allow 2 min for CO₂ to clear from the chamber before subsequent euthanasia procedures, unless the chamber is manipulated to increase the dissipation rate.

  11. D0 central tracking chamber performance studies

    International Nuclear Information System (INIS)

    Pizzuto, D.

    1991-12-01

    The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e - events

  12. A study of energy resolution in a gridded ionization chamber filled with tetramethylsilane and tetramethylgermanium

    International Nuclear Information System (INIS)

    Hara, H.; Ohnuma, H.; Hoshi, Y.; Yuta, H.; Abe, K.; Suekane, F.; Neichi, M.; Nakajima, T.; Masuda, K.

    1998-01-01

    The energy resolutions of 976 keV conversion electrons from a 207 Bi source are measured in a gridded ionization chamber filled with tetramethylsilane (TMS) and tetramethylgermanium (TMG), and are found to be about 5.7 and 5.5% (rms) for TMS and TMG, respectively. We also deduce a simple method of estimating the electron lifetime using a gridded ionization chamber. The electron lifetime, free ion yield and thermalization length for these liquids are measured by this simple method

  13. Gamma compensated pulsed ionization chamber wide range neutron/reactor power measurement system

    International Nuclear Information System (INIS)

    Ellis, W.H.

    1975-01-01

    An improved method and system of pulsed mode operation of ionization chambers is described in which a single sensor system with gamma compensation is provided by sampling, squaring, automatic gate selector, and differential amplifier circuit means, employed in relation to chambers sensitized to neutron plus gamma and gamma only to subtract out the gamma component, wherein squaring functions circuits, a supplemental high performance pulse rate system, and operational and display mode selection and sampling gate circuits are utilized to provide automatic wide range linear measurement capability for neutron flux and reactor power. Neon is employed as an additive in the ionization chambers to provide independence of ionized gas kinetics temperature effects, and the pulsed mode of operation provide independence of high temperature insulator leakage effects. (auth)

  14. Characterization of ionization chambers in double face for X-ray detection systems

    International Nuclear Information System (INIS)

    Costa, Alessandro M. da; Caldas, Linda V.O.

    2000-01-01

    Two identical parallel-plate ionization chambers with collecting electrodes of different materials (in order to obtain different energy dependences), developed at Instituto de Pesquisas Energeticas e Nucleares, were tested in low energy X-radiation beams, simulating a special ionization chamber, of double face, in a Tandem system. The purpose of this work is to justify a project of a double face detection system utilizing ionization chambers in Tandem. In relation to conventional methods, this kind of system will provide more efficient and precise absorbed dose in air measurements and radiation effective energy determinations. The results obtained in relation to characteristics of short- and long-term stabilities and angular and energy dependence show that the project is feasible and very appropriate. (author)

  15. Low noise amplifier for ZnS(Ag) scintillation chamber

    International Nuclear Information System (INIS)

    Do Hoang Cuong

    1998-01-01

    A new pulse amplifier that can be used with standard photomultiplier tubes coupled with Zn(Ag) scintillation chamber is presented. The amplifier based on an IC operational amplifier LF 356N consists of a low-noise charge sensitive preamplifier and pulse shaping circuits for optimization of signal to noise ratio. Temperature instability is ≤ 0.05%/ o C. Dynamic range for linear output signals is equal +7 V. The presented amplifier is used in a measuring head for 0.17 L Lucas chambers developed in Department of Nuclear Instruments and Methods of the INCT in laboratory investigations aimed to develop methods and instruments for measurement of radon concentration in the air. The amplifier can also be employed for measurement of ionizing radiation by means of other scintillators coupled to PM tube. The amplifier is followed by a pulse discriminator with adjustable discrimination level. The amplifier output signal and discriminator output pulses are fed to external devices. (author)

  16. Development, construction and test of the planar forward drift chambers of the ZEUS inner detector and analyses of chamber properties

    International Nuclear Information System (INIS)

    Kramarczyk, S.

    1993-08-01

    The three planar drift chambers FTD1-3 are part of the inner tracking system of the ZEUS detector at the ep facility HERA, DESY. Together with 2x2 transition radiation modules they form the Forward Detector which covers the range of forward (proton) angles. Development, construction and tests of the drift chambers are described, emphasizing design features and details of the manufacture. Two compensation methods were tested to annihilate the cross talk which emerges from the influence of one signal wire on the others in the same drift cell. A prototyp system of the final digital readout electronics was used together with a test cell. The single wire resolution was studied with optimized drift time algorithms. For the first time it was possible to measure the influence of the track angle on the single wire resolution of the FTDs. (orig.)

  17. "Diamond" over-coated Microstrip Gas Chambers for high rate operation

    CERN Document Server

    Barr, A J; Bouclier, Roger; Capéans-Garrido, M; Dominik, Wojciech; Hoch, M; Manzin, G; Million, Gilbert; Ropelewski, Leszek; Sauli, Fabio; Sharma, A

    1997-01-01

    We describe the recent developments on the diamond-like carbon (DLC) over-coated Microstrip Gas Chambers made on drawn glass substrates. MSGC surface coating with thin DLC layer of stable and controlled resistivity was proposed to overcome the limitation of detector operation due to surface charging-up under avalanches. This brings also advantages for the detector manufacturing technology. The thin layer, deposited on top of a manufactured MSGC (over-coating), demonstrates excellent mechanical properties and very good stability. We report on recent measurements with DLC over-coated MSGCs of various surface resistivities (ranging from 1013W/r to 1016W/r) on D-263 and AF45 glass substrates. Over-coated MSGCs exhibit good rate capability for the resistivity of the surface around 1015W/r. Stable operation up to 50 mC/cm of accumulated charge from avalanches has been demonstrated.

  18. Ion-recombination correction factor κsat for spherical ion chambers irradiated by continuous photom beams

    International Nuclear Information System (INIS)

    Piermattei, A.; Azario, L.; Arcovito, G.

    1996-01-01

    The large range of reference air kerma rates of brachytherapy sources involves the use of large-volume ionization chambers. When such ionization chambers are used the ion-recombination correction factor k sat has to be determined. In this paper three spherical ion chambers with volume ranging from 30 to 10 4 cm 3 have been irradiated by photons of a 192 Ir source to determine the k sat factors. The ionization currents of the ion chambers as a function of the applied voltage and the air kerma rate have been analysed to determine the contribution of the initial and general ion recombination. The k sat values for large-volume ionization chambers obtained by considering the general ion recombination as predominant (Almond's approach) are in disagreement with the results obtained using methods that consider both initial and general ion-recombination contributions (Niatel's approach). Such disagreement can reach 0.7% when high currents are measured for a high-activity source calibration in terms of reference air kerma rate. In this study a new 'two-voltage' method, independent of the voltage ratio given by a dosimetry system, is proposed for practical dosimetry of continuous x-and gamma-radiation beams. In the case where the Almond approach is utilized, the voltage ratio V 1 /V 2 should be less than 2 instead of Almond's limit of V 1 /V 2 <5. (Author)

  19. Argus drift chamber

    Energy Technology Data Exchange (ETDEWEB)

    Danilov, M; Nagovizin, V; Hasemann, H; Michel, E; Schmidt-Parzefall, W; Wurth, R; Kim, P

    1983-11-15

    The ARGUS detector came into operation at the DORIS-II e/sup +/s/sup -/ storage ring at the end of 1982. Its two meter long drift chamber contains 5940 sense and 24588 field wires organized in uniform 18x18.8 mm/sup 2/ drift cells filling the whole volume. These cells form 36 layers, 18 of which provide stereo views. Each sense wire is equipped with a single hit TDC and ADC for coordinate and dE/dx measurements. The chamber is operated with propane to improve momentum and dE/dx resolution. The drift chamber design and initial performance are presented. With a very crude space-time relation approximation and without all the necessary corrections applied a spatial resolution of about 200 ..mu..m was obtained for half of the drift cell volume. Further corrections should improve this result. An intrinsic dE/dx resolution of 4.2% and an actual resolution of 5% were obtained for cosmic muons and also for Bhabha scattered electrons. An actual dE/dx resolution of 5.6% was obtained for pions from e/sup +/e/sup -/ annihilation data with almost no track selection. A relativistic rise of 30% was observed in good agreement with theory. The long-term stability is still to be investigated.

  20. The wide gap resistive plate chamber

    International Nuclear Information System (INIS)

    Crotty, I.; Lamas Valverde, J.; Hatzifotiadou, D.; Williams, M.C.S.; Zichichi, A.

    1995-01-01

    The resistive plate chamber (RPC) has good time and position resolution; these factors (coupled to its simple construction) make it an attractive candidate for muon trigger systems at future colliders. However, operated in spark mode, the RPC has severe rate problems that make it unusable above 10 Hz/cm 2 . We have previously published our results concerning the operation of the RPC in spark and in avalanche mode; we have shown that the rate limit can be increased to 150 Hz/cm 2 if the RPC is operated in avalanche mode. Here, we discuss the performance of chambers with 6 and 8 mm gas gaps (compared to the more usual 2 mm gap). We outline the reasons for this choice, and also discuss anode versus cathode strip readout. We have measured the efficiency versus flux, and also show that an enhanced rate limit can be obtained if only a small region of the chamber is exposed to the beam (spot illumination). Finally we have tested the performance of chambers constructed with other materials for the resistiv e plate and compare it to chambers constructed with our preferred plastic, melamine laminate. (orig.)

  1. HYLIFE-II reactor chamber design refinements

    International Nuclear Information System (INIS)

    House, P.A.

    1994-06-01

    Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams (Li 2 BeF 4 ) are used for shielding and blast protection of the chamber walls. The system is designed for a 6 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (>12 m/s) salt streams and also recover up to half of the dynamic head. Cost estimates for a 1 GWe and 2 GWe reactor chamber are presented

  2. Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, L. L. W.; La Russa, D. J.; Rogers, D. W. O. [Ottawa Carleton Institute of Physics, Carleton University, Campus Ottawa, Ottawa, Ontario KIS 5B6 (Canada)

    2009-05-15

    In a previous study [Med. Phys. 35, 1747-1755 (2008)], the authors proposed two direct methods of calculating the replacement correction factors (P{sub repl} or p{sub cav}p{sub dis}) for ion chambers by Monte Carlo calculation. By ''direct'' we meant the stopping-power ratio evaluation is not necessary. The two methods were named as the high-density air (HDA) and low-density water (LDW) methods. Although the accuracy of these methods was briefly discussed, it turns out that the assumption made regarding the dose in an HDA slab as a function of slab thickness is not correct. This issue is reinvestigated in the current study, and the accuracy of the LDW method applied to ion chambers in a {sup 60}Co photon beam is also studied. It is found that the two direct methods are in fact not completely independent of the stopping-power ratio of the two materials involved. There is an implicit dependence of the calculated P{sub repl} values upon the stopping-power ratio evaluation through the choice of an appropriate energy cutoff {Delta}, which characterizes a cavity size in the Spencer-Attix cavity theory. Since the {Delta} value is not accurately defined in the theory, this dependence on the stopping-power ratio results in a systematic uncertainty on the calculated P{sub repl} values. For phantom materials of similar effective atomic number to air, such as water and graphite, this systematic uncertainty is at most 0.2% for most commonly used chambers for either electron or photon beams. This uncertainty level is good enough for current ion chamber dosimetry, and the merits of the two direct methods of calculating P{sub repl} values are maintained, i.e., there is no need to do a separate stopping-power ratio calculation. For high-Z materials, the inherent uncertainty would make it practically impossible to calculate reliable P{sub repl} values using the two direct methods.

  3. A multi purpose 4 π counter spherical ionization chamber type

    International Nuclear Information System (INIS)

    Calin, Marian Romeo; Calin, Adrian Cantemir

    2004-01-01

    A pressurized ionization chamber detector able to measure radioactive sources in internal 2π or 4π geometry was built in order to characterize alpha and beta radioactive sources, i.e. to calibrate these sources by relative method and to test the behavior of gas mixtures in pressurized-gas radiation detectors. The detector we made is of spherical shape and works by collecting in a uniform electric field the ionization charges resulting from the interaction of ionizing radiation with gas in the sensitive volume of the chamber. An ionizing current proportional to the activity of the radioactive source to be measured is obtained. In this paper a gas counter with a spherical symmetry is described. This detector can work in a very satisfactory manner, either as a flow counter or as a ionization chamber reaching in the latter case a good α pulse height resolution, even with large emitting sources. Calculations are made in order to find the dependence of the pulse shape on the direction of emission of an α-particle by a point source in the chamber (finite track). A good agreement is found between these calculations and the experimental tests performed, which show that this dependence can be employed in high efficiency measurements of angular α-γ correlations. (authors)

  4. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  5. MDT Commissioning Procedures Guidelines for Certifying RFI Chambers

    CERN Document Server

    Beretta, M; Branchini, P; Kourkoumelis, C; Dubbert, J; Gazis, E N; Hertenberger, R; Hurst, P; Kojine, A; Lanza, A; Marin, A; Mockett, P; Petridou, C; Tskhadadze, E G; Valente, P; Wotschack, J; Xie, Y; Zhao, Z

    2004-01-01

    Aim of the document is the definition of a common set of guidelines and test procedures for commissioning the MDT chambers. Commissioning is different for Barrel and Endcap chambers. The former will be tested at a single chamber level before going to the ATLAS pit, ready for the last quick test before final installation, while the latter will be first tested at a single chamber level (phase one), then installed into the Small and Big Wheel sectors (SW and BW), tested after the integration (phase two) and transported to the ATLAS pit for final wheel installation. The present document concerns all tests, including those of phase two for Endcap chambers, but it is possible that some specific tests, at the moment not planned, will be implemented during the Endcap phase two commissioning. It is composed of three sections: 1 â€" Guidelines for checking chamber conformity, where the main rules for declaring that chambers conform to the reference drawings and requirements are described; 2 â€" Commissioning tests,...

  6. Local and accumulated truncation errors in a class of perturbative numerical methods

    International Nuclear Information System (INIS)

    Adam, G.; Adam, S.; Corciovei, A.

    1980-01-01

    The approach to the solution of the radial Schroedinger equation using piecewise perturbative theory with a step function reference potential leads to a class of powerful numerical methods, conveniently abridged as SF-PNM(K), where K denotes the order at which the perturbation series was truncated. In the present paper rigorous results are given for the local truncation errors and bounds are derived for the accumulated truncated errors associated to SF-PNM(K), K = 0, 1, 2. They allow us to establish the smoothness conditions which have to be fulfilled by the potential in order to ensure a safe use of SF-PNM(K), and to understand the experimentally observed behaviour of the numerical results with the step size h. (author)

  7. Lifetime survivability of contaminated target-chamber optics

    International Nuclear Information System (INIS)

    Rainer, F.; Anderson, A.; Burnham, A.; Milam, D.; Turner, R.

    1996-11-01

    Target chambers used for Inertial Confinement Fusion (ICF) expose laser optics to a very hostile environment, not only from high-fluence laser irradiation but also x-ray irradiation and particulate debris from targets and chamber wall materials. Expendable debris shields provide the first line of defense to more costly optics upstream in the laser beam path to contaminants generated within the target chamber. However, the replacement of a large number of debris shields is also an expensive proposition so that extending their usable lifetime within the chamber is important. We have conducted tests to show that optics can both be cleaned and damaged by laser irradiation at 355 nm after being contaminated with potential chamber-wall materials such as B 4 C and Al 2 O 3 . Such optics can survive from one to hundreds of laser shots, depending on degree of contamination and laser fluence levels. Similarly, we have studied the survivability of optics that have been exposed to direct contamination from representative target materials irradiated in the target chamber. We have also studied the effects on optics that were not directly exposed to targets, yet received secondary exposure from the above directly-exposed samples

  8. Technical Note: Influence of Compton currents on profile measurements in small-volume ion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Tanny, Sean; Sperling, Nicholas; Parsai, E. Ishmael, E-mail: e.parsai@utoledo.edu [Department of Radiation Oncology, University of Toledo Medical Center, 1325 Conference Drive, Toledo, Ohio 43614 (United States); Holmes, Shannon [Standard Imaging, 3120 Deming Way, Middleton, Wisconsin 53562 (United States)

    2015-10-15

    Purpose: This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. Methods: Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed. Static point measurements, output factors, and cable only irradiations were performed to determine the contribution of Compton currents to various components of the chamber. Monte Carlo simulations were performed to evaluate why one microchamber showed a significant reduction in Compton current generation. Results: Beam profiles demonstrated significant distortion for two of the three chambers when scanned parallel to the chamber axis, produced by electron deposition within the wire. Measurements of ionization produced within the cable identified Compton current generation as the cause of these distortions. The size of the central collecting wire was found to have the greatest influence on the magnitude of Compton current generation. Conclusions: Microchambers can demonstrate significant (>5%) deviations from properties as measured with larger volume chambers (0.125 cm{sup 3} and above). These deviations can be substantially reduced by averaging measurements conducted at opposite polarities.

  9. Possibilities to improve sensitivity and rendering of detail of streamer chamber track photographs

    Energy Technology Data Exchange (ETDEWEB)

    Baehr, J

    1975-01-01

    Streamer chambers are increasingly used as effective particle detectors in the field of experimental elementary particle physics. The photographic recording of high energy events in streamer chambers is limited by performance of current photographic silver-halide layers. Similar limiting problems occur in other fields as well, e.g., in astronomy, x-ray medicine and photogrammetry; therefore methods have been developed to increase sensitivity and improve the information transfer of the emulsion. In this paper these methods have been classified and summarized under the aspect of their application to streamer image recording. Proposals for further investigations are given. Especially the applicability of these methods, their possibility of combination to large film lengths should be investigated The detective quantum efficiency (DQE) is proposed as criterion to estimate and compare the different methods.

  10. Simulations in the Analysis of Experimental Data Measured by BM@N Drift Chambers

    Science.gov (United States)

    Fedorišin, Ján

    2018-02-01

    The drift chambers (DCH's) are an important part of the tracking system of the BM@N experiment designed to study the production of baryonic matter at the Nuclotron energies. The method of particle hit and track reconstruction in the drift chambers has been already proposed and tested on the BM@N deuteron beam data. In this study the DCH's are first locally and globally aligned, and subsequently the consistency of the track reconstruction chain is tested by two methods. The first one is based on the backward extrapolation of the DCH reconstructed deuteron beam to a position where its deflection in the BM@N magnetic field begins. The second method reconstructs the deuteron beam momentum through its deflection angle. Both methods confirm correctness of the track reconstruction algorithm.

  11. A two dimensional finite difference time domain analysis of the quiet zone fields of an anechoic chamber

    Science.gov (United States)

    Ryan, Deirdre A.; Luebbers, Raymond J.; Nguyen, Truong X.; Kunz, Karl S.; Steich, David J.

    1992-01-01

    Prediction of anechoic chamber performance is a difficult problem. Electromagnetic anechoic chambers exist for a wide range of frequencies but are typically very large when measured in wavelengths. Three dimensional finite difference time domain (FDTD) modeling of anechoic chambers is possible with current computers but at frequencies lower than most chamber design frequencies. However, two dimensional FDTD (2D-FTD) modeling enables much greater detail at higher frequencies and offers significant insight into compact anechoic chamber design and performance. A major subsystem of an anechoic chamber for which computational electromagnetic analyses exist is the reflector. First, an analysis of the quiet zone fields of a low frequency anechoic chamber produced by a uniform source and a reflector in two dimensions using the FDTD method is presented. The 2D-FDTD results are compared with results from a three dimensional corrected physical optics calculation and show good agreement. Next, a directional source is substituted for the uniform radiator. Finally, a two dimensional anechoic chamber geometry, including absorbing materials, is considered, and the 2D-FDTD results for these geometries appear reasonable.

  12. Modeling of thermal mode of drying special purposes ceramic products in batch action chamber dryers

    Science.gov (United States)

    Lukianov, E. S.; Lozovaya, S. Yu; Lozovoy, N. M.

    2018-03-01

    The article is devoted to the modeling of batch action chamber dryers in the processing line for producing shaped ceramic products. At the drying stage, for various reasons, most of these products are warped and cracked due to the occurrence of irregular shrinkage deformations due to the action of capillary forces. The primary cause is an untruly organized drying mode due to imperfection of chamber dryers design specifically because of the heat-transfer agent supply method and the possibility of creating a uniform temperature field in the whole volume of the chamber.

  13. Vacuum Chamber for the Booster Bending Magnets

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).

  14. Construction and performance of large flash chambers

    International Nuclear Information System (INIS)

    Taylor, F.E.; Bogert, D.; Fisk, R.; Stutte, L.; Walker, J.K.; Wolfson, J.; Abolins, M.; Ernwein, J.; Owen, D.; Lyons, T.

    1979-01-01

    The construction and performance of 12' x 12' flash chambers used in a 340 ton neutrino detector under construction at Fermilab is described. The flash chambers supply digital information with a spatial resolution of 0.2'', and are used to finely sample the shower development of the reaction products of neutrino interactions. The flash chambers are easy and inexpensive to build and are electronically read out

  15. The knife-edge chamber

    International Nuclear Information System (INIS)

    Barasch, E.F.; Bowcock, T.J.V.; Drew, M.M.; Elliott, S.M.; Lee, B.; McIntyre, P.M.; Pang, Y.; Popovic, M.; Smith, D.D.

    1990-01-01

    In this paper the design for a new technology for particle track detectors is described. Using standard IC fabrication techniques, a pattern of microscopic knife edges and field-shaping electrodes can be fabricated on a silicon substrate. The knife-edge chamber uniquely offers attractive performance for the track chambers required for SSC detectors, for which no present technology is yet satisfactory. Its features include: excellent radiation hardness (10 Mrad), excellent spatial resolution (∼20 μm), short drift time (20 ns), and large pulse height (1 mV)

  16. Multiple chamber ionization detector

    International Nuclear Information System (INIS)

    Solomon, E.E.

    1982-01-01

    An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector

  17. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  18. Characteristics Air Flow in Room Chamber Test Refrigerator Household Energy Consumption with Inlet Flow Variation

    Science.gov (United States)

    Susanto, Edy; Idrus Alhamid, M.; Nasruddin; Budihardjo

    2018-03-01

    Room Chamber is the most important in making a good Testing Laboratory. In this study, the 2-D modeling conducted to assess the effect placed the inlet on designing a test chamber room energy consumption of household refrigerators. Where the geometry room chamber is rectangular and approaching the enclosure conditions. Inlet varied over the side parallel to the outlet and compared to the inlet where the bottom is made. The purpose of this study was to determine and define the characteristics of the airflow in the room chamber using CFD simulation. CFD method is used to obtain flow characteristics in detail, in the form of vector flow velocity and temperature distribution inside the chamber room. The result found that the position of the inlet parallel to the outlet causes air flow cannot move freely to the side of the floor, even flow of air moves up toward the outlet. While by making the inlet is below, the air can move freely from the bottom up to the side of the chamber room wall as well as to help uniform flow.

  19. 21 CFR 866.2120 - Anaerobic chamber.

    Science.gov (United States)

    2010-04-01

    ... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...

  20. Optimisation of the parameters of a pump chamber for solid-state lasers with diode pumping by the optical boiler method

    Energy Technology Data Exchange (ETDEWEB)

    Kiyko, V V; Kislov, V I; Ofitserov, E N; Suzdal' tsev, A G [A M Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2015-06-30

    A pump chamber of the optical boiler type for solid-state lasers with transverse laser diode pumping is studied theoretically and experimentally. The pump chamber parameters are optimised using the geometrical optics approximation for the pump radiation. According to calculations, the integral absorption coefficient of the active element at a wavelength of 808 nm is 0.75 – 0.8 and the relative inhomogeneity of the pump radiation distribution over the active element volume is 17% – 19%. The developed pump chamber was used in a Nd:YAG laser. The maximum cw output power at a wavelength of 1064 nm was ∼480 W at the optical efficiency up to 19.6%, which agrees with theoretical estimates. (lasers)

  1. Semi-empirical approach for calibration of CR-39 detectors in diffusion chambers for radon measurements

    International Nuclear Information System (INIS)

    Pereyra A, P.; Lopez H, M. E.; Palacios F, D.; Sajo B, L.; Valdivia, P.

    2016-10-01

    Simulated and measured calibration of PADC detectors is given for cylindrical diffusion chambers employed in environmental radon measurements. The method is based on determining the minimum alpha energy (E min ), average critical angle (<Θ c >), and fraction of 218 Po atoms; the volume of the chamber (f 1 ), are compared to commercially available devices. Radon concentration for exposed detectors is obtained from induced track densities and the well-established calibration coefficient for NRPB monitor. Calibration coefficient of a PADC detector in a cylindrical diffusion chamber of any size is determined under the same chemical etching conditions and track analysis methodology. In this study the results of numerical examples and comparison between experimental calibration coefficients and simulation purpose made code. Results show that the developed method is applicable when uncertainties of 10% are acceptable. (Author)

  2. A small flat fission chamber

    International Nuclear Information System (INIS)

    Li Yijun; Wang Dalun; Chen Suhe

    1999-01-01

    With fission materials of depleted uranium, natural uranium, enriched uranium, 239 Pu, and 237 Np, the authors have designed and made a series of small flat fission chamber. The authors narrated the construction of the fission chamber and its technological process of manufacture, and furthermore, the authors have measured and discussed the follow correct factor, self-absorption, boundary effect, threshold loss factor, bottom scatter and or so

  3. Automated correction on X-rays calibration using transmission chamber and LabVIEWTM

    International Nuclear Information System (INIS)

    Betti, Flavio; Potiens, Maria da Penha Albuquerque

    2009-01-01

    Uncertainties during prolonged exposure times on X-rays calibration procedures at the Instruments Calibration facilities at IPEN may suffer from efficiency (and therefore intensity) variations on the industrial X-Ray generator used. Using a transmission chamber as an online reference chamber during the whole irradiation process is proposed in order to compensate for such error source. Also temperature (and pressure) fluctuations may arise from the performance limited calibration room air conditioning system. As an open ionization chamber, that monitor chamber does require calculation of a correction factor due to the temperature and pressure effects on air density. Sending and processing data from all related instruments (electrometer, thermometer and barometer) can be more easily achieved by interfacing them to a host computer running an especially developed algorithm using LabVIEW TM environment which will not only apply the proper correction factors during runtime, but also determine the exact length of time to reach a desired condition, which can be: time period, charge collected, or air kerma, based on the previous calibration of the whole system using a reference chamber traceable to primary standard dosimetry laboratories. When performing such calibration, two temperature sensors (secondary standard thermistors) are simultaneously used, one for the transmission chamber, and other for the reference chamber. As the substitution method is used during actual customer's calibration, the readings from the second thermistor can also be used when desired for further corrections. Use of LabVIEW TM programming language allowed for a shorter development time, and it is also extremely convenient to make things easier when improvements and modifications are called for. (author)

  4. Report from Workshop on VOCs in diving chambers

    International Nuclear Information System (INIS)

    Crosbie, A.; Simpson, M.

    2000-05-01

    This report of the 'Setting the Standards' workshop on the problems of volatile organic compounds (VOCs) in diving in offshore operations, sponsored jointly by the UK Health and Safety Executive Offshore Safety Division and the Stolt Rockwater Joint Venture, gives details of the papers presented covering the chemical contamination of diver's atmosphere, sampling protocols and methods, analytical procedures used for VOCs in hyperbaric chambers, and contamination in buildings. The setting of exposure limits in the UK, the derivation of threshold limiting values (TVLs), the selection of Tenax tubes for atmospheric sampling, organic contaminant monitoring, and NASA's approach to contamination in the space environment are examined, and dealing with contamination problems in a submarine atmosphere, and the simulation of a condensate spillage in a diving bell are discussed. Guidelines for the measurement of VOCs in hyperbaric chambers are given in the appendices

  5. Intragroup Processes and Teamwork within a Successful Chamber Choir

    Science.gov (United States)

    Kirrane, Melrona; O'Connor, Cliodhna; Dunne, Ann-Marie; Moriarty, Patricia

    2017-01-01

    Despite the ubiquity of choirs across time and cultures, relatively little is known about the internal dynamics of these social systems. This article examines the group processes involved in a small European chamber choir. The research adopted a mixed-methods qualitative approach that combined individual interviews (n = 13) with ethnographic…

  6. Lifetime tests for MAC vertex chamber

    International Nuclear Information System (INIS)

    Nelson, H.

    1986-01-01

    A vertex chamber for MAC was proposed in fall 1983 to increase precision in the measurement of the B hadron and tau lepton lifetimes. The chamber had to be placed within the existing central drift chamber, making access for repairs difficult and costly. Therefore for detector elements thin-walled aluminized mylar drift tubes (straws) were used because of their simplicity and robustness. The diameter of the drift tubes was 6.9 mm. The radial extent of the proposed chamber was from 3 cm to 10 cm, the inner wall of the central drift. It was clear that radiation levels, from synchrotron x-rays and overfocussed electrons, were potentially high. Since the drift distance is short in the straws, it was desirable to operate them at the highest possible gas gain, to achieve the best spatial resolution. There was a likelihood of drawing large currents in the chamber and thus causing radiation damage. Therefore a study of radiation hardness under the conditions of their proposed design was undertaken. In tests, argon-hydrocarbon mixtures consistently became unusable at ∼0.05 C/cm collected charge, due to anode buildup. Argon-CO 2 mixtures, while underquenched, were operational to 0.25 C/cm, at which point loss of cathode material became intolerable. Argon-xenon-CO 2 proved to be quenched as well as argon-hydrocarbons, but was limited by cathode damage. The MAC vertex chamber has operated at a distance of 4.6 cm from the e + e - interaction point at PEP for two years and has shown no aging effects

  7. Acoustic-Levitation Chamber

    Science.gov (United States)

    Barmatz, M. B.; Granett, D.; Lee, M. C.

    1984-01-01

    Uncontaminated environments for highly-pure material processing provided within completely sealed levitation chamber that suspends particles by acoustic excitation. Technique ideally suited for material processing in low gravity environment of space.

  8. Vacuum system for the test accumulation ring for the NUMATRON project (TARN)

    International Nuclear Information System (INIS)

    Mizobuchi, Akira

    1979-01-01

    The vacuum system for the test accumulation ring for the NUMATRON project (TARN) being constructed in the Institute for Nuclear Study, University of Tokyo, for the purpose of accumulating fundamental data on high energy, heavy ion acceleration is presented. The main specifications of TARN are as follows: repetition rate 1 Hz, average radius 5.06 m, the radius of curvature 1.333 m, circumference 31.795 m, the length of a unit cell 3.974 m, the length of a long straight section 1.8 m, the number of unit cells 8, superperiodicity 8, and the structure of a unit cell FODO. The vacuum level of TARN lower than 1 x 10 -10 Torr is necessary. The preliminary test apparatuses, number one and two, for obtaining the basic data on superhigh vacuum were constructed. The characteristics of a molecular vacuum pump and the high temperature baking effect were tested with the number one test apparatus. The glow discharge cleaning effect of the model vacuum chamber for deflecting magnets was tested, utilizing the number two test apparatus. The pressure curve in course of time during pump down, the residual gas components, the residual gas spectrum in vacuum state and the change of residual gas components before and after the glow discharge cleaning are shown as these testing results. The vacuum gauges, which are used for TARN for measuring both the total pressure and the partial pressure of gas, are explained. The vacuum system, the vacuum chamber, the vacuum pumps, the expected exhausting speed and the partial functional test results for the vacuum system are introduced. (Nakai, Y.)

  9. Usefulness of hemocytometer as a counting chamber in a computer assisted sperm analyzer (CASA)

    Science.gov (United States)

    Eljarah, A.; Chandler, J.; Jenkins, J.A.; Chenevert, J.; Alcanal, A.

    2013-01-01

    Several methods are used to determine sperm cell concentration, such as the haemocytometer, spectrophotometer, electronic cell counter and computer-assisted semen analysers (CASA). The utility of CASA systems has been limited due to the lack of characterization of individual systems and the absence of standardization among laboratories. The aims of this study were to: 1) validate and establish setup conditions for the CASA system utilizing the haemocytometer as a counting chamber, and 2) compare the different methods used for the determination of sperm cell concentration in bull semen. Two ejaculates were collected and the sperm cell concentration was determined using spectrophotometer and haemocytometer. For the Hamilton-Thorn method, the haemocytometer was used as a counting chamber. Sperm concentration was determined three times per ejaculate samples. A difference (P 0.05) or between the haemocytometer count and the spectrophotometer. Based on the results of this study, we concluded that the haemocytometer can be used in computerized semen analysis systems as a substitute for the commercially available disposable counting chambers, therefore avoiding disadvantageous high costs and slower procedures.

  10. Development and operational performance of a single calibration chamber for radon detectors

    International Nuclear Information System (INIS)

    Lopez-Coto, I.; Bolivar, J.P.; Mas, J.L.; Garcia-Tenorio, R.; Vargas, A.

    2007-01-01

    This work shows the design, setup and performance of a new single radon detector calibration chamber developed at the University of Huelva (Environmental Radioactivity Group). This system is based on a certified radon source and a traceable reference radon detector, which allows radon concentrations inside the chamber radon to be obtained in steady-state conditions within a range of 400-22 000 Bq m -3 with associated uncertainties in the range of 4%. In addition, the development of a new ad hoc calibration protocol (UHU-RC/01/06 'Rachel'), which is based on the modelling of radon concentration within the chamber, allows it to be used without the reference detector. To do that, a complete characterization and calibration of the different leakage constants and the flow meter reading have been performed. The accuracy and general performance of both working methods for the same chamber (i.e., with and without the reference detector) have been tested by means of their participation in an intercomparison exercise involving five active radon monitors

  11. Space charge effect measurements for a multi-channel ionization chamber used for synchrotron radiation

    International Nuclear Information System (INIS)

    Nasr, Amgad

    2012-01-01

    In vivo coronary angiography is one of the techniques used to investigate the heart diseases, by using catheter to inject a contrast medium of a given absorption coefficient into the heart vessels. Taking X-ray images produced by X-ray tube or synchrotron radiation for visualizing the blood in the coronary arteries. As the synchrotron radiation generated by the relativistic charged particle at the bending magnets, which emits high intensity photons in comparison with the X-ray tube. The intensity of the synchrotron radiation is varies with time. However for medical imaging it's necessary to measure the incoming intensity with the integrated time. The thesis work includes building a Multi-channel ionization chamber which can be filled with noble gases N 2 , Ar and Xe with controlled inner pressure up to 30 bar. This affects the better absorption efficiency in measuring the high intensity synchrotron beam fluctuation. The detector is a part of the experimental setup used in the k-edge digital subtraction angiography project, which will be used for correcting the angiography images taken by another detector at the same time. The Multi-channel ionization chamber calibration characteristics are measured using 2 kW X-ray tube with molybdenum anode with characteristic energy of 17.44 keV. According to the fast drift velocity of the electrons relative to the positive ions, the electrons will be collected faster at the anode and will induce current signals, while the positive ions is still drifting towards the cathode. However the accumulation of the slow ions inside the detector disturbs the homogeneous applied electric field and leads to what is known a space charge effect. In this work the space charge effect is measured with very high synchrotron photons intensity from EDR beam line at BESSYII. The strong attenuation in the measured amplitude signal occurs when operating the chamber in the recombination region. A plateau is observed at the amplitude signal when

  12. Study of a proportional chamber for the detection of muons in the CELLO experiment

    International Nuclear Information System (INIS)

    Durand, Alain.

    1978-01-01

    The physics of e + e - interactions that the CELLO experiment is proposing to do requires good μ detection. For this, the prototype of a wire type proportional chamber with integrated logical system read-out is under study. The various phenomena that govern the working of a wire type proportional chamber are recalled first of all. Section II deals with the various working and read-out modes. Section III is devoted to the description of the method chosen and its advantages. In Sections IV and V, the two more specifically studied read-out methods are presented and it is shown that the read-out method by delay line proves to be much more delicate to use than the integrated electronic method finally selected [fr

  13. Repair of isolated double-chambered right ventricle | El Kouache ...

    African Journals Online (AJOL)

    The finding of a double-chambered right ventricle (DCRV) is exceptionally rare as an isolated anomaly. It is a congenital cardiac anomaly in which the right ventricle is separated into two chambers, a proximal highpressure chamber and a distal low-pressure chamber, by anomalous muscles or fibrous tissues in the right ...

  14. Complications and Mortality of Single Versus Dual Chamber Implantable Cardioverter Defibrillators

    Directory of Open Access Journals (Sweden)

    Ataallah Bagherzadeh

    2006-04-01

    Full Text Available Background: The implantable cardioverter defibrillators (ICDs are increasingly being used as a treatment modality for life threatening tachyarrhythmia. The purpose of this study was to compare the frequency of complications and mortality between single-chamber and dual-chamber ICD implantation in Shahid Rajaie cardiovascular center. Methods and results: Between January 2000 and December 2004, 234 patients received ICD by a percutaneous transvenous approach and were followed for 33 ± 23 months. The cumulative incidence of complications was 9.4% over the follow-up period. There was no significant difference in overall complication rate between single chamber (VR and dual chamber (DR ICD groups in the follow-up period (P= 0.11. The risk of complications did not have any statistically significant difference in secondary versus primary prevention groups (P=0.06. The complications were not associated with the severity of left ventricular systolic dysfunction (P=0.16.The frequency of lead-related complications was higher in dual chamber ICDs in comparison with single chamber ICDs (P=0.02. There was no significant difference in mortality between different sex groups (P=0.37, different indications for ICD implantation (P=0.43 or between VR and DR ICD groups (P= 0.55. Predictors of mortality were NYHA class III or more (P65 years (P=0.011 and LVEF<30% (P<0.001. The mortality in patients with CAD and DCM were significantly higher than those with other structural heart diseases (P=0.001. Conclusions: Close monitoring of patients during the first 2 month after ICD implantation is recommended because the majority of complications occur early after the procedure.

  15. Vacuum chamber 'bicone'

    CERN Multimedia

    1977-01-01

    This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).

  16. Accelerated search of gamma-quantum families in a X-ray emulsion chamber

    International Nuclear Information System (INIS)

    Takibaev, Zh.S.; Bajgubekov, A.S.; Sadykov, T.Kh.

    1977-01-01

    The criteria are derived allowing to considerably accelerate the process of detecting the pure gamma-quantum families. The suitable criterion is the apparent size of the distribution of black spots due to electromagnetic cascades inside a circle of specific radius. The results of assaying 27 gamma-families with energies above 3 TeV generated in a target above the chamber are presented. The method of search for the target families suggested in this paper allows to cut four-fold the roentgen-emulsion cloud chamber treatment time

  17. Fabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics

    Directory of Open Access Journals (Sweden)

    Koroush Arbabi

    2007-12-01

    Full Text Available Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measurement principals of well type chambers were considered and MCNP-4C code as a calculation tool was used. The designed chamber was simulated and the response of the chamber was evaluated. In this investigation, the chamber operational parameters such as operating voltage, leakage current, reproducibility, reference measuring point, recombination and polarization factors as well as response stability for 137Cs, 57Co and 241Am sources were studied. Results: The chamber leakage currents at the operating voltage in comparison to the chamber response for the measurement of the above mentioned sources were negligible. The responses of the fabricated chamber for these sources are reproducible and its reference measurement position for these sources was obtained at 6 cm from the bottom of the chamber. The recombination factor for the well type chamber was negligible and the polarization factor is close to 1. Therefore, these two factors were not considered in the measurements. The reproducibility of the measurements in different intervals shows the stability of the chamber response for each source. Also the results of the chamber current measurement in term of source strength were compared to the response of the simulated chamber for different source positions and energy ranges of the used sources. Discussion and Conclusion: The results show that the measurement of the reference positions for each source in the simulated and fabricated chamber is quite in a good agreement. Regarding the reliable operational properties of the fabricated chamber, this chamber can be

  18. Influence of Reduced Mass Flow Rate and Chamber Backpressure on Swirl Injector Fluid Mechanics

    Science.gov (United States)

    Kenny, R Jeremy; Hulka, James R.

    2008-01-01

    Industry interest in variable-thrust liquid rocket engines places a demand on engine injector technology to operate over a wide range of liquid mass flow rates and chamber backpressures. One injection technology of current interest for variable thrust applications is an injector design with swirled fluids. Current swirl injector design methodologies do not take into account how swirl injector design parameters respond to elevated chamber backpressures at less than design mass flow rates. The current work was created to improve state-of-the-art swirl injector design methods in this area. The specific objective was to study the effects of elevated chamber backpressure and off-design mass flow rates on swirl injector fluid mechanics. Using a backpressure chamber with optical access, water was flowed through a swirl injector at various combinations of chamber backpressure and mass flow rates. The film thickness profile down the swirl injector nozzle section was measured through a transparent nozzle section of the injector. High speed video showed measurable increases in the film thickness profile with application of chamber backpressure and mass flow rates less than design. At prescribed combinations of chamber backpressure and injected mass flow rate, a discrete change in the film thickness profile was observed. Measured injector discharge coefficient values showed different trends with increasing chamber backpressure at low mass flow rates as opposed to near-design mass flow rates. Downstream spray angles showed classic changes in morphology as the mass flow rate was decreased below the design value. Increasing chamber backpressure decreased the spray angle at any injection mass flow rate. Experimental measurements and discussion of these results are reported in this paper.

  19. Study on target interactions in emulsion chamber - Brasil-Japan emulsion chamber collaboration

    Science.gov (United States)

    Ballester, M.; Santos, C.; Bellandi Filho, J.; Chinellato, J. A.; Dobrigkeit, C.; Lattes, C. M. G.; Marques, A.; Menon, M. J.; Navia, C. E.; Sawayanagi, K.

    Experimental results are presented from observations of 80 target nuclear interactions where the total gamma-ray energy is greater than or equal to 20 TeV. Evidence is presented for the existence of two types of interactions; the interpretation is given on the basis of a fire-ball model. Two-story emulsion chambers exposed at Mount Chacaltaya, in Bolivia (5,220 m above sea level), are used. Gamma rays from nuclear interactions in the target layer of petroleum pitch (1/3 of the nuclear mean free path in thickness) are detected through observations of the electron showers generated by them in the lower chamber

  20. Climate chamber for environmentally controlled laboratory airflow experiments.

    Science.gov (United States)

    Even-Tzur, Nurit; Zaretsky, Uri; Grinberg, Orly; Davidovich, Tomer; Kloog, Yoel; Wolf, Michael; Elad, David

    2010-01-01

    Climate chambers have been widely used in in vitro and in vivo studies which require controlled environmental temperature and humidity conditions. This article describes a new desktop climate chamber that was developed for application of respiratory airflows on cultured nasal epithelial cells (NEC) under controlled temperature and humidity conditions. Flow experiments were performed by connecting the climate chamber to an airflow generator via a flow chamber with cultured NEC. Experiments at two controlled climate conditions, 25 degrees C and 40% relative humidity (RH) and 37 degrees C and 80%RH, were conducted to study mucin secretion from the cultures inresponse to the flow. The new climate chamber is a relatively simple and inexpensive apparatus which can easily be connected to any flow system for climate controlled flow experiments. This chamber can be easily adjusted to various in vitro experiments, as well as to clinical studies with animals or human subjects which require controlled climate conditions.

  1. Investigation of a multiwire proportional chamber

    International Nuclear Information System (INIS)

    Konijn, J.

    1976-01-01

    The article discusses some aspects of a prototype multiwire proportional chamber for electron detection located at IKO in Amsterdam, i.e. voltage, counting rates, noise and gas mixture (argon, ethylene bromide). The efficiency and performance of the chamber have been investigated and an error analysis is given

  2. Triangular tube proportional wire chamber system

    Energy Technology Data Exchange (ETDEWEB)

    Badtke, D H; Bakken, J A; Barnett, B A; Blumenfeld, B J; Chien, C Y; Madansky, L; Matthews, J A.J.; Pevsner, A; Spangler, W J [Johns Hopkins Univ., Baltimore, MD (USA); Lee, K L [California Univ., Berkeley (USA). Lawrence Berkeley Lab.

    1981-10-15

    We report on the characteristics of the proportional tube chamber system which has been constructed for muon identification in the PEP-4 experiment at SLAC. The mechanical and electrical properties of the extruded aluminum triangular tubes allow these detectors to be used as crude drift chambers.

  3. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  4. The OPAL vertex drift chamber

    International Nuclear Information System (INIS)

    Carter, J.R.; Elcombe, P.A.; Hill, J.C.; Roach, C.M.; Armitage, J.C.; Carnegie, R.K.; Estabrooks, P.; Hemingway, R.; Karlen, D.; McPherson, A.; Pinfold, J.; Roney, J.M.; Routenburg, P.; Waterhouse, J.; Hargrove, C.K.; Klem, D.; Oakham, F.G.; Carter, A.A.; Jones, R.W.L.; Lasota, M.M.B.; Lloyd, S.L.; Pritchard, T.W.; Wyatt, T.R.

    1990-01-01

    A high precision vertex drift chamber has been installed in the OPAL experiment at LEP. The design of the chamber and the associated readout electronics is described. The performance of the system has been studied using cosmic ray muons and the results of these studies are presented. A space resolution of 50 μm in the drift direction is obtained using the OPAL central detector gas mixture at 4 bar. (orig.)

  5. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  6. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  7. Test Methodologies for Hydrogen Sensor Performance Assessment: Chamber vs. Flow Through Test Apparatus: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Buttner, William J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hartmann, Kevin S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Schmidt, Kara [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cebolla, Rafeal O [Joint Research Centre, Petten, the Netherlands; Weidner, Eveline [Joint Research Centre, Petten, the Netherlands; Bonato, Christian [Joint Research Centre, Petten, the Netherlands

    2017-11-06

    Certification of hydrogen sensors to standards often prescribes using large-volume test chambers [1, 2]. However, feedback from stakeholders such as sensor manufacturers and end-users indicate that chamber test methods are often viewed as too slow and expensive for routine assessment. Flow through test methods potentially are an efficient, cost-effective alternative for sensor performance assessment. A large number of sensors can be simultaneously tested, in series or in parallel, with an appropriate flow through test fixture. The recent development of sensors with response times of less than 1s mandates improvements in equipment and methodology to properly capture the performance of this new generation of fast sensors; flow methods are a viable approach for accurate response and recovery time determinations, but there are potential drawbacks. According to ISO 26142 [1], flow through test methods may not properly simulate ambient applications. In chamber test methods, gas transport to the sensor can be dominated by diffusion which is viewed by some users as mimicking deployment in rooms and other confined spaces. Alternatively, in flow through methods, forced flow transports the gas to the sensing element. The advective flow dynamics may induce changes in the sensor behaviour relative to the quasi-quiescent condition that may prevail in chamber test methods. One goal of the current activity in the JRC and NREL sensor laboratories [3, 4] is to develop a validated flow through apparatus and methods for hydrogen sensor performance testing. In addition to minimizing the impact on sensor behaviour induced by differences in flow dynamics, challenges associated with flow through methods include the ability to control environmental parameters (humidity, pressure and temperature) during the test and changes in the test gas composition induced by chemical reactions with upstream sensors. Guidelines on flow through test apparatus design and protocols for the evaluation of

  8. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  9. 30 CFR 56.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...

  10. Scale testing of a partially confined blast chamber

    CSIR Research Space (South Africa)

    Grundling, W

    2012-10-01

    Full Text Available in pressure readings. A scale model of the blast chamber, Emily, was constructed with the addition of a pendulum plate hanging concentrically covering 65% of the open area. PURPOSE OF SCALED BLAST CHAMBER The purpose of this particular test is to evaluate... PHASE Illustrated in Figure 3 and 4 are the results obtained during testing of the scaled blast chamber. In both cases the pressure dissipates over time, showing pulsating behaviour as the shockwaves reflect off the chamber walls. By looking...

  11. Recent developments in wire chamber tracking at SSC

    International Nuclear Information System (INIS)

    Ogren, H.

    1990-01-01

    All of the major SSC proposed detectors use wire chambers in their tracking systems. The feasibility of wire chambers in an SSC detector has now been established by a number of groups planning detectors at SSC. The major advances during the past year in understanding straw tube drift chambers are presented and several innovations in gaseous wire chambers are discussed. The R and D section will concentrate on progress in drift cell design, electronics and signal processing, and engineering aspects of the tracking designs

  12. TH-AB-201-08: Ion Chamber Dose Measurements - Problems with the Temperature-Pressure Correction Factor

    Energy Technology Data Exchange (ETDEWEB)

    Bourgouin, A [Carleton University, Ottawa, Ontario (Canada); McEwen, M [National Research Council, Ottawa, ON (Canada)

    2016-06-15

    Purpose: To investigate the behavior of ionization chambers over a wide pressure range. Methods: Three cylindrical and two parallel-plate designs of ion chamber were investigated. The ion chambers were placed in vessel where the pressure was varied from atmospheric (101 kPa) down to 5 kPa. Measurements were made using 60Co and high-energy electron beams. The pressure was measured to better than 0.1% and multiple data sets were obtained for each chamber at both polarities to investigate pressure cycling and dependency on the sign of the charge collected. Results: For all types of chamber, the ionization current, corrected using the standard PTP, showed a similar behaviour. Deviations from the standard theory were generally small for Co-60 but very significant for electron beams, up to 20 % below P = 10 kPa. The effect was found to be always larger when collecting negative charge, suggesting a dependence on free-electron collection. The most likely source of such electrons is low-energy electrons emitted from the electrodes. This signal would be independent of air pressure within the chamber cavity. The data was analyzed to extract this signal and it was found to be a non-negligible component of the ionization current at atmospheric pressure. In the case of the parallel plate chambers, the effect was approximately 0.25 %. For the cylindrical chambers the effect was larger - up to 1.2 % - and dependent on the chamber type, which would be consistent with electron emission from different wall materials. For the electron beams, the correction factor was dependent on the electron energy and approximately double that observed in 60Co. Conclusion: Measurements have indicated significant deviations of the standard pressure correction that are consistent with electron emission from chamber electrodes. This has implications for both primary standard and reference ion chamber-based dosimetry.

  13. Optical spark chamber

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.

  14. The Honeycomb Strip Chamber

    International Nuclear Information System (INIS)

    Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei

    1991-06-01

    The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs

  15. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  16. Prediction of methylmercury accumulation in rice grains by chemical extraction methods

    International Nuclear Information System (INIS)

    Zhu, Dai-Wen; Zhong, Huan; Zeng, Qi-Long; Yin, Ying

    2015-01-01

    To explore the possibility of using chemical extraction methods to predict phytoavailability/bioaccumulation of soil-bound MeHg, MeHg extractions by three widely-used extractants (CaCl 2 , DTPA, and (NH 4 ) 2 S 2 O 3 ) were compared with MeHg accumulation in rice grains. Despite of variations in characteristics of different soils, MeHg extracted by (NH 4 ) 2 S 2 O 3 (highly affinitive to MeHg) correlated well with grain MeHg levels. Thus (NH 4 ) 2 S 2 O 3 extraction, solubilizing not only weakly-bound and but also strongly-bound MeHg, may provide a measure of ‘phytoavailable MeHg pool’ for rice plants. Besides, a better prediction of grain MeHg levels was obtained when growing condition of rice plants was also considered. However, MeHg extracted by CaCl 2 or DTPA, possibly quantifying ‘exchangeable MeHg pool’ or ‘weakly-complexed MeHg pool’ in soils, may not indicate phytoavailable MeHg or predict grain MeHg levels. Our results provided the possibility of predicting MeHg phytoavailability/bioaccumulation by (NH 4 ) 2 S 2 O 3 extraction, which could be useful in screening soils for rice cultivation in contaminated areas. - Highlights: • MeHg extraction by (NH 4 ) 2 S 2 O 3 correlates well with its accumulation in rice grains. • MeHg extraction by (NH 4 ) 2 S 2 O 3 provides a measure of phytoavailable MeHg in soils. • Some strongly-bound MeHg could be desorbed from soils and available to rice plants. • MeHg extraction by CaCl 2 or DTPA could not predict grain MeHg levels. - Methylmercury extraction from soils by (NH 4 ) 2 S 2 O 3 could possibly be used for predicting methylmercury phytoavailability and its bioaccumulation in rice grains

  17. Equipment for handling ionization chamber

    International Nuclear Information System (INIS)

    Altmann, J.

    1988-01-01

    The device consists of an ionization channel with an ionization chamber, of a support ring, axial and radial bearings, a sleeve, a screw gear and an electric motor. The ionization chamber is freely placed on the bottom of the ionization channel. The bottom part of the channel deviates from the vertical axis. The support ring propped against the axial bearing in the sleeve is firmly fixed to the top part of the ionization channel. The sleeve is fixed to the reactor lid. Its bottom part is provided with a recess for the radial bearing which is propped against a screw wheel firmly connected to the ionization channel. In measuring neutron flux, the screw wheel is rotated by the motor, thus rotating the whole ionization channel such that the ionization chamber is displaced into the reactor core.(J.B.). 1 fig

  18. Molecular desorption of stainless steel vacuum chambers irradiated with 4.2 MeV/u lead ions

    CERN Document Server

    Mahner, E; Laurent, Jean Michel; Madsen, N

    2003-01-01

    In preparation for the heavy ion program of the Large Hadron Collider (LHC) at CERN, accumulation and cooling tests with lead ion beams have been performed in the Low Energy Antiproton Ring (LEAR). These tests have revealed that due to the unexpected large outgassing of the vacuum system, the dynamic pressure of the ring could not be maintained low enough to reach the required beam intensities. To determine the actions necessary to lower the dynamic pressure rise, an experimental program has been initiated for measuring the molecular desorption yields of stainless steel vacuum chambers by the impact of 4.2 MeV/u lead ions with the charge states +27 and +53. The test chambers were exposed either at grazing or at perpendicular incidence. Different surface treatments (glow-discharges, non-evaporable getter coating) are reported in terms of the molecular desorption yields for H2, CH4, CO, Ar and CO2. Unexpected large values of molecular yields per incident ion up to 2 104 molecules/ion have been observed. The red...

  19. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Provetti Cunha

    2014-04-01

    Full Text Available Purpose: The aim of this study was to investigate possible predictive factors related to anterior chamber fibrin formation after vitreoretinal surgery in a large series of patients. Methods: The data of 185 eyes of 185 patients submitted to vitreoretinal surgery was reviewed. The following variables were evaluated: the postoperatively presence of fibrin, age, diabetes mellitus, the vitrectomy system gauge (20, 23 or 25 gauge, the type of vitreous substitute, the influence of prior surgical procedures and the combination with cataract extraction. To evaluate predictive factors for anterior chamber fibrin formation, univariate analysis was performed. A multivariate stepwise logistic regression model was adjusted to investigate factors associated with fibrin formation (p<0.05. Results: Fibrinoid anterior chamber reaction was found in 12 (6.4% patients. For multivariate logistic regression analysis, balanced salt solution (BSS, the chance of fibrin occurrence was 5 times greater (odds ratio 4.83, CI 95% 1.302 - 17.892; p=0.019, while combination with phacoemulsification increased the chance of fibrin formation by 20 times (odds ratio 20, CI 95% 2.480 - 161.347; p=0.005. No significant difference was found regarding other variables. Conclusion: Anterior chamber fibrin formation is an unwanted complication after vitreoretinal surgery. Factors such as combined performance of phacoemulsification and the use of balanced salt solution as a vitreous substitute may predispose the occurrence of this complication.

  20. N. plumbaginifolia zeaxanthin epoxidase transgenic lines have unaltered baseline ABA accumulations in roots and xylem sap, but contrasting sensitivities of ABA accumulation to water deficit.

    Science.gov (United States)

    Borel, C; Audran, C; Frey, A; Marion-Poll, A; Tardieu, F; Simonneau, T

    2001-03-01

    A series of transgenic lines of Nicotiana plumbaginifolia with modified expression of zeaxanthin epoxidase gene (ZEP) provided contrasting ABA accumulation in roots and xylem sap. For mild water stress, concentration of ABA in the xylem sap ([ABA](xylem)) was clearly lower in plants underexpressing ZEP mRNA (complemented mutants and antisense transgenic lines) than in wild-type. In well-watered conditions, all lines presented similar [ABA](xylem) and similar ABA accumulation rates in detached roots. Plants could, therefore, be grown under normal light intensities and evaporative demand. Both ZEP mRNA abundance and ABA accumulation rate in roots increased with water deficit in all transgenic lines, except in complemented aba2-s1 mutants in which the ZEP gene was controlled by a constitutive promoter which does not respond to water deficit. These lines presented no change in root ABA content either with time or dehydration. The increase in ZEP mRNA abundance in roots with decreasing RWC was more pronounced in detached roots than in whole plants, suggesting a difference in mechanism. In all transgenic lines, a linear relationship was observed between predawn leaf water potential and [ABA](xylem), which could be reproduced in several experiments in the greenhouse and in the growth chamber. It is therefore possible to represent the effect of the transformation by a single parameter, thereby allowing the use of a quantitative approach to assist understanding of the behaviour of transgenic lines.

  1. Semi-empirical approach for calibration of CR-39 detectors in diffusion chambers for radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pereyra A, P.; Lopez H, M. E. [Pontificia Universidad Catolica del Peru, Av. Universitaria 1801, San Miguel Lima 32 (Peru); Palacios F, D.; Sajo B, L. [Universidad Simon Bolivar, Laboratorio de Fisica Nuclear, Apartado 89000 Caracas (Venezuela, Bolivarian Republic of); Valdivia, P., E-mail: ppereyr@pucp.edu.pe [Universidad Nacional de Ingenieria, Av. Tupac Amaru s/n, Rimac, Lima 25 (Peru)

    2016-10-15

    Simulated and measured calibration of PADC detectors is given for cylindrical diffusion chambers employed in environmental radon measurements. The method is based on determining the minimum alpha energy (E{sub min}), average critical angle (<Θ{sub c}>), and fraction of {sup 218}Po atoms; the volume of the chamber (f{sub 1}), are compared to commercially available devices. Radon concentration for exposed detectors is obtained from induced track densities and the well-established calibration coefficient for NRPB monitor. Calibration coefficient of a PADC detector in a cylindrical diffusion chamber of any size is determined under the same chemical etching conditions and track analysis methodology. In this study the results of numerical examples and comparison between experimental calibration coefficients and simulation purpose made code. Results show that the developed method is applicable when uncertainties of 10% are acceptable. (Author)

  2. Weld Development for Aluminum Fission Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Cross, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Jesse Norris [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-16

    The Sigma welding team was approached to help fabricate a small fission chamber (roughly ½ inch dia. x ½ inch tall cylinder). These chambers are used as radiation sensors that contain small traces of radionuclides (Cf 252, U 235, and U 238) that serve to ionize gas atoms in addition to external radiation. When a voltage is applied within the chamber, the resulting ion flow can be calibrated and monitored. Aluminum has the advantage of not forming radioactive compounds when exposed to high external radiation (except from minor Na alloy content). Since aluminum has not been used before in this application, this presented an unexplored challenge.

  3. BEBC Big European Bubble Chamber

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.

  4. Results from the MAC Vertex chamber

    International Nuclear Information System (INIS)

    Nelson, H.N.

    1987-05-01

    The design, construction, and performance characteristics of a high precision gaseous drift chamber made of thin walled proportional tubes are described. The device achieved an average spatial resolution of 45 μm in use for physics analysis with the MAC detector. The B-lifetime result obtained with this chamber is discussed

  5. Measurement and Compensation of BPM Chamber Motion in HLS

    Science.gov (United States)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-06-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  6. Measurement and Compensation of BPM Chamber Motion in HLS

    International Nuclear Information System (INIS)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-01-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  7. Lyophilization Cycle Design for Dual Chamber Cartridges and a Method for Online Process Control: The "DCC LyoMate" Procedure.

    Science.gov (United States)

    Korpus, Christoph; Friess, Wolfgang

    2017-08-01

    Freeze-drying process design is a challenging task that necessitates a profound understanding of the complex interrelation among critical process parameters (e.g., shelf temperature and chamber pressure), heat transfer characteristics of the involved materials (e.g., product containers and holder devices), and critical quality attributes of the product (e.g., collapse temperatures). The Dual Chamber Cartridge "(DCC) LyoMate" (from lyophilization and automated) is a manometric temperature measurement-based process control strategy that was developed within this study to streamline this complicated task. It was successfully applied using 5% sucrose formulations with 0.5 and 1 mL fill volumes. The system was further challenged using 2, 20, and 100 mg/mL monoclonal antibody formulations. The DCC LyoMate method did not only produce pharmaceutically acceptable cakes but was also able to maintain the desired product temperature irrespective of formulation and protein content. It enabled successful process design even at high protein concentrations and aided the design and online control of the lyophilization process for drying in DCCs within a single development run. Thus, it helps to reduce development cost and the DCC LyoMate can also be easily installed on every freeze-dryer capable of performing a manometric temperature measurement, without the need for hardware modification. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  8. 30 CFR 57.7807 - Flushing the combustion chamber.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...

  9. Development of fission micro-chambers for nuclear waste incineration studies

    CERN Document Server

    Fadil, M; Christophe, S; Deruelle, O; Fioni, G; Marie, F; Mounier, C; Ridikas, D; Trapp, J P

    2002-01-01

    The Incineration by Accelerator (INCA) project of the Directorate for Science of Matter of the French Atomic Energy Authority (CEA/DSM) aims to outline the ideal physical conditions to transmute minor actinides in a high intensity neutron flux obtained either by hybrid systems or innovative critical reactors. To measure on-line the incineration rates of minor actinides, we are developing an innovative Double Deposit Fission Chamber (DDFC) working in current mode. Our method is based on a comparison between the isotope under study and a reference material whose nuclear parameters are well known, as sup 2 sup 3 sup 5 U and sup 2 sup 3 sup 9 Pu. This new fission chamber will be used in the High Flux Reactor in Grenoble/France in a neutron flux of 1.2x10 sup 1 sup 5 n cm sup - sup 2 s sup - sup 1 for 50 days, the operating cycle of the reactor. These specific experimental conditions require substantial modifications of the existing chambers. The first experiment will be carried out in fall 2000.

  10. Study and analysis of drift chamber parameters

    International Nuclear Information System (INIS)

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  11. Tuned Chamber Core Panel Acoustic Test Results

    Science.gov (United States)

    Schiller, Noah H.; Allen, Albert R.

    2016-01-01

    This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.

  12. A plant chamber system with downstream reaction chamber to study the effects of pollution on biogenic emissions

    NARCIS (Netherlands)

    Timovsky, J.; Gankema, Paulien; Pierik, Ronald; Holzinger, Rupert

    2014-01-01

    A system of two plant chambers and a downstream reaction chamber has been set up to investigate the emission of biogenic volatile organic compounds (BVOCs) and possible effects of pollutants such as ozone. The system can be used to compare BVOC emissions from two sets of differently treated plants,

  13. Construction and Test of New Precision Drift-Tube Chambers for Upgrades of the ATLAS Muon Spectrometer in 2016/17

    CERN Document Server

    INSPIRE-00218480; Kortner, O.; Müller, F.; Nowak, S.; Schmidt-Sommerfeld, K.

    2016-01-01

    Small-diameter Muon Drift Tube (sMDT) chambers have been developed for the ATLAS muon detector upgrade. They possess an improved rate capability and a more compact design with respect to the existing chambers, which allows to equip detector regions uninstrument at present. The chamber assembly methods have been optimized for mass production, while the sense wire positioning accuracy is improved to below ten microns. The chambers will be ready for installation in the winter shutdown 2016/17 of the Large Hadron Collider. The design and construction of the new sMDT chambers for ATLAS will be discussed as well as measurements of their precision and performance.

  14. Magma accumulation or second boiling - Investigating the ongoing deformation field at Montserrat, West Indies

    Science.gov (United States)

    Collinson, Amy; Neuberg, Jurgen; Pascal, Karen

    2016-04-01

    For over 20 years, Soufriere Hills Volcano, Montserrat has been in a state of volcanic unrest. Intermittent periods of dome building have been punctuated by explosive eruptions and dome collapse events, endangering the lives of the inhabitants of the island. The last episode of active magma extrusion was in February 2010, and the last explosive event (ash venting) in March 2012. Despite a lack of eruptive activity recently, the volcano continues to emit significant volumes of SO2 and shows an ongoing trend of island inflation. Through the aid of three-dimensional numerical modelling, using a finite element method, we explore the potential sources of the ongoing island inflation. We consider both magmatic (dykes and chamber) and tectonic sources. Whilst a magmatic source suggests the possibility for further eruption, a tectonic source may indicate cessation of volcanic activity. We show that a magmatic source is the most likely scenario, and illustrate the effect of different sources (shapes, characters and depths) on the surface displacement. Furthermore, through the inclusion of topographic data, we investigate how the topography may affect the displacement pattern at the surface. We investigate the conflicting scenarios of magma chamber resupply versus second boiling - crystallisation-induced degassing. Based on numerical modelling results, we suggest the required pressurisation is too high for crystallisation-induced degassing to be the dominant process - thereby suggesting magma accumulation may be ongoing. However, we show that second boiling may be a contributing factor, particularly when taking into account the local tectonics and regional stretching.

  15. RF Anechoic Chambers, Tri-Service Research Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — In collaboration with the Navy, there are 12 RF Anechoic and static free exposure chambers located at TSRL. These chambers cover the majority of the RF spectrum and...

  16. Analysis of a water-coolant leak into a very high-temperature vitrification chamber

    International Nuclear Information System (INIS)

    Felicione, F. S.

    1998-01-01

    A coolant-leakage incident occurred during non-radioactive operation of the Plasma Hearth Process waste-vitrification development system at Argonne National Laboratory when a stray electric arc ruptured az water-cooling jacket. Rapid evaporation of the coolant that entered the very high-temperature chamber pressurized the normally sub-atmospheric system above ambient pressure for over 13 minutes. Any positive pressurization, and particularly a lengthy one, is a safety concern since this can cause leakage of contaminants from the system. A model of the thermal phenomena that describe coolant/hot-material interactions was developed to better understand the characteristics of this type of incident. The model is described and results for a variety of hypothetical coolant-leak incidents are presented. It is shown that coolant leak rates above a certain threshold will cause coolant to accumulate in the chamber, and evaporation from this pool can maintain positive pressure in the system long after the leak has been stopped. Application of the model resulted in reasonably good agreement with the duration of the pressure measured during the incident. A closed-form analytic solution is shown to be applicable to the initial leak period in which the peak pressures are generated, and is presented and discussed

  17. Smog chamber study on the evolution of fume from residential coal combustion.

    Science.gov (United States)

    Geng, Chunmei; Wang, Kun; Wang, Wei; Chen, Jianhua; Liu, Xiaoyu; Liu, Hongjie

    2012-01-01

    Domestic coal stoves are widely used in countryside and greenbelt residents in China for heating and cooking, and emit considerable pollutants to the atmosphere because of no treatment of their exhaust, which can result in deteriorating local air quality. In this study, a dynamic smog chamber was used to investigate the real-time emissions of gaseous and particulate pollutants during the combustion process and a static smog chamber was used to investigate the fume evolution under simulate light irradiation. The real-time emissions revealed that the total hydrocarbon (THC) and CO increased sharply after ignition, and then quickly decreased, indicating volatilization of hydrocarbons with low molecular weight and incomplete combustion at the beginning stage of combustion made great contribution to these pollutants. There was evident shoulder peak around 10 min combustion for both THC and CO, revealing the emissions from vitrinite combustion. Additionally, another broad emission peak of CO after 30 min was also observed, which was ascribed to the incomplete combustion of the inertinite. Compared with THC and CO, there was only one emission peak for NOx, SO2 and particular matters at the beginning stage of combustion. The fume evolution with static chamber simulation indicated that evident consumption of SO2 and NOx as well as new particle formation were observed. The consumption rates for SO2 and NOx were about 3.44% hr(-1) and 3.68% hr(-1), the new particle formation of nuclei particles grew at a rate of 16.03 nm/hr during the first reaction hour, and the increase of the diameter of accumulation mode particles was evident. The addition of isoprene to the diluted mixture of the fume could promote 03 and secondary particle formation.

  18. System of multiwire proportional chambers at the separated particle channel for the Mirabelle bubble chamber

    International Nuclear Information System (INIS)

    Bryukhanov, N.S.; Galyaev, N.A.; Kotov, V.I.; Prosin, B.V.; Romanov, Yu.A.; Khodyrev, Yu.S.

    1980-01-01

    A system of multiwire proportional chambers (MPC) operating on-line with a M-6000 computer used during tuning and monitoring of beam parameters in a separated particle channel for the Mirabelle bubble chamber is described. Peculiarities of the construction and main characteristics of two MPC versions are considered. The first version is intended for placing in a vacuum at the edges of high-frequency separator deflector, the second one - for placing outside a vacuum in ionoguide gaps. Power supply of the proportional chambers is carried out from local compact (160x95x50 mm) high-voltage sources remotely controlled from a channel panel by low voltage. A MPC position diagram in the accelerator channel, flowsheet of registering electronics for the MPC system, main circuits of high-voltage power source, analog-to-digital converter of a code and trunk amplifier are given. A graph of amplifier signal amplitude dependence on high voltage of a chamber for a different composition of a gaseous mixture is presented. It is noted that the used elements of the electronic system provide the reliable processing of data and its transmission for a great distance (approximately 400 m). It is underlined that the MPC system operation for a long time has shown its high efficiency and reliability

  19. Monte Carlo modeling of ion chamber performance using MCNP.

    Science.gov (United States)

    Wallace, J D

    2012-12-01

    Ion Chambers have a generally flat energy response with some deviations at very low (2 MeV) energies. Some improvements in the low energy response can be achieved through use of high atomic number gases, such as argon and xenon, and higher chamber pressures. This work looks at the energy response of high pressure xenon-filled ion chambers using the MCNP Monte Carlo package to develop geometric models of a commercially available high pressure ion chamber (HPIC). The use of the F6 tally as an estimator of the energy deposited in a region of interest per unit mass, and the underlying assumptions associated with its use are described. The effect of gas composition, chamber gas pressure, chamber wall thickness, and chamber holder wall thicknesses on energy response are investigated and reported. The predicted energy response curve for the HPIC was found to be similar to that reported by other investigators. These investigations indicate that improvements to flatten the overall energy response of the HPIC down to 70 keV could be achieved through use of 3 mm-thick stainless steel walls for the ion chamber.

  20. Construction of a full-length prototype of the BESIII drift chamber and on-detector test for the BESIII drift chamber electronics

    International Nuclear Information System (INIS)

    Qin Zhonghua; Wu Linghui; Liu Jianbei; Chinese Academy of Sciences, Beijing; Yan Zhikang; Hunan Univ., Changsha; Chen Yuanbo; Chen Chang; Xu Meihang; Wang Lan; Ma Xiaoyan; Jin Yan; Liu Rongguang; Tang Xiao; Zhang Guifang; Zhu Qiming; Sheng Huayi; Zhu Kejun

    2007-01-01

    A full-length prototype of the BESIII drift chamber was built. The experience gained on gas sealing, high voltage supply and front-end electronics installation should be greatly beneficial to the successful construction of the BESIII drift chamber. An on-detector test of the BESIII drift chamber electronics was carried out with the constructed prototype chamber. The noise performance, drift time and charge measurements, and electronics gains were examined specifically. The final test results indicate that the electronics have a good performance and can satisfy their design requirements. (authors)