WorldWideScience

Sample records for absorption refrigerating machines

  1. Thermodynamic evaluation of new absorbent mixtures of lithium bromide and organic salts for absorption refrigeration machines

    Energy Technology Data Exchange (ETDEWEB)

    Donate, Marina; Rodriguez, Luis; Lucas, Antonio De; Rodriguez, Juan F. [Department of Chemical Engineering, University of Castilla-La Mancha, Avda. de Camilo Jose Cela s/n, 13004 Ciudad Real (Spain)

    2006-01-01

    Mixtures of lithium bromide and organic salts of sodium and potassium (formate, acetate and lactate) have been evaluated as alternative absorbents for absorption refrigeration machines. The main objective is to overpass the limitations of lithium bromide and improve the characteristics and the efficiency of the refrigeration cycle. In order to select the mixture that presents better properties for its employment in absorption refrigeration cycles, a thermodynamic analysis have been done. Density, viscosity, enthalpies of dilution, solubility and vapour pressure data of the proposed mixtures have been measured. A simulation program has been developed to evaluate temperatures, heats exchanged in the different sections and the efficiency of the cycle. (author)

  2. Solution procedure and performance evaluation for a water–LiBr absorption refrigeration machine

    International Nuclear Information System (INIS)

    Wonchala, Jason; Hazledine, Maxwell; Goni Boulama, Kiari

    2014-01-01

    The water–lithium bromide absorption cooling machine was investigated theoretically in this paper. A detailed solution procedure was proposed and validated. A parametric study was conducted over the entire admissible ranges of the desorber, condenser, absorber and evaporator temperatures. The performance of the machine was evaluated based on the circulation ratio which is a measure of the system size and cost, the first law coefficient of performance and the second law exergy efficiency. The circulation ratio and the coefficient of performance were seen to improve as the temperature of the heat source increased, while the second law performance deteriorated. The same qualitative responses were obtained when the temperature of the refrigerated environment was increased. On the other hand, simultaneously raising the condenser and absorber temperatures was seen to result in a severe deterioration of both the circulation ratio and first law coefficient of performance, while the second law performance indicator improved significantly. The influence of the difference between the condenser and absorber exit temperatures, as well as that of the internal recovery heat exchanger on the different performance indicators was also calculated and discussed. - Highlights: • Analysis of a water–LiBr absorption machine, including detailed solution procedure. • Performance assessed using first and second law considerations, as well as flow ratio. • Effects of heat source and refrigerated environment temperatures on the performance. • Effects of the difference between condenser and absorber temperatures. • Effects of internal heat exchanger efficiency on overall cooling machine performance

  3. Parametric study of an absorption refrigeration machine using advanced exergy analysis

    International Nuclear Information System (INIS)

    Gong, Sunyoung; Goni Boulama, Kiari

    2014-01-01

    An advanced exergy analysis of a water–lithium bromide absorption refrigeration machine was conducted. For each component of the machine, the proposed analysis quantified the irreversibility that can be avoided and the irreversibility that is unavoidable. It also identified the irreversibility originating from inefficiencies within the component and the irreversibility that does not originate from the operation of the considered component. It was observed that the desorber and absorber concentrated most of the exergy destruction. Furthermore, the exergy destruction at these components was found to be dominantly endogenous and unavoidable. A parametrical study has been presented discussing the sensitivity of the different performance indicators to the temperature at which the heat source is available, the temperature of the refrigerated environment, and the temperature of the cooling medium used at the condenser and absorber. It was observed that the endogenous avoidable exergy destruction at the desorber, i.e. the portion of the desorber irreversibility that could be avoided by improving the design and operation of the desorber, decreased when the heat source or the temperature at which the cooling effect was generated increased, and it decreased when the heat sink temperature increased. The endogenous avoidable exergy destruction at the absorber displayed the same variations, though it was observed to be less affected by the heat source temperature. Contrary to the aforementioned two components, the exergy destruction at the evaporator and condenser were dominantly endogenous and avoidable, with little sensitivity to the cycle operating parameters. - Highlights: • Endogenous, exogenous, avoidable and unavoidable irreversibilities were calculated for a water–LiBr absorption machine. • Overall, desorber and absorber concentrated most of the exergy destruction of the cycle. • The exergy destruction was mainly endogenous and unavoidable for the desorber and

  4. Refrigerating machine oil

    Energy Technology Data Exchange (ETDEWEB)

    Nozawa, K.

    1981-03-17

    Refrigerating machine oil to be filled in a sealed motorcompressor unit constituting a refrigerating cycle system including an electric refrigerator, an electric cold-storage box, a small-scaled electric refrigerating show-case, a small-scaled electric cold-storage show-case and the like, is arranged to have a specifically enhanced property, in which smaller initial driving power consumption of the sealed motor-compressor and easier supply of the predetermined amount of the refrigerating machine oil to the refrigerating system are both guaranteed even in a rather low environmental temperature condition.

  5. Compression-absorption (resorption) refrigerating machinery. Modeling of reactors; Machine frigorifique a compression-absorption (resorption). Modelisation des reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Lottin, O.; Feidt, M.; Benelmir, R. [LEMTA-UHP Nancy-1, 54 - Vandoeuvre-les-Nancy (France)

    1997-12-31

    This paper is a series of transparencies presenting a comparative study of the thermal performances of different types of refrigerating machineries: di-thermal with vapor compression, tri-thermal with moto-compressor, with ejector, with free piston, adsorption-type, resorption-type, absorption-type, compression-absorption-type. A prototype of ammonia-water compression-absorption heat pump is presented and modeled. (J.S.)

  6. Quantum Absorption Refrigerator

    Science.gov (United States)

    Levy, Amikam; Kosloff, Ronnie

    2012-02-01

    A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold, and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified; the cooling power Jc vanishes as Jc∝Tcα, when Tc→0, where α=d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

  7. 49 CFR 173.174 - Refrigerating machines.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Refrigerating machines. 173.174 Section 173.174 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY... Refrigerating machines. A refrigerating machine assembled for shipment and containing 7 kg (15 pounds) or less...

  8. Thermodynamic Analysis of the Irreversibilities in Solar Absorption Refrigerators

    Directory of Open Access Journals (Sweden)

    Emma Berrich Betouche

    2016-03-01

    Full Text Available A thermodynamic analysis of the irreversibility on solar absorption refrigerators is presented. Under the hierarchical decomposition and the hypothesis of an endoreversible model, many functional and practical domains are defined. The effect of external heat source temperature on the entropy rate and on the inverse specific cooling load (ISCL multiplied by the total area of the refrigerator A/Qe are studied. This may help a constructor to well dimension the solar machine under an optimal technico-economical criterion A/Qe and with reasonable irreversibility on the refrigerator. The solar concentrator temperature effect on the total exchanged area, on the technico-economical ratio A/Qe, and on the internal entropy rate are illustrated and discussed. The originality of these results is that they allow a conceptual study of a solar absorption refrigeration cycle.

  9. Dynamic model of an autonomous solar absorption refrigerator

    International Nuclear Information System (INIS)

    Ali Fellah; Tahar Khir; Ammar Ben Brahim

    2009-01-01

    The performance analysis of a solar absorption refrigerator operating in an autonomous way is investigated. The water/LiBr machine satisfies the air-conditioning needs along the day. The refrigerator performances were simulated regarding a dynamic model. For the solar driven absorption machines, two applications could be distinguished. The sun provides the thermal part of the useful energy. In this case, it is necessary to use additional energy as the electric one to activate the pumps, the fans and the control system. On the other hand, the sun provides all the necessary energy. Here, both photovoltaic cells and thermal concentrators should be used. The simulation in dynamic regime of the cycle requires the knowledge of the geometric characteristics of every component as the exchange areas and the internal volumes. Real characteristics of a refrigerator available at the applied thermodynamic research unit (ATRU) at the engineers' national school of Gabes are notified. The development of the thermal and matter balances in every component of the cycle has permitted to simulate in dynamic regime the performances of a solar absorption refrigerator operating with the water/LiBr couple for air-conditioning needs. The developed model could be used to perform intermittent refrigeration cycle autonomously driven. (author)

  10. The Absorption Refrigerator as a Thermal Transformer

    Science.gov (United States)

    Herrmann, F.

    2009-01-01

    The absorption refrigerator can be considered a thermal transformer, that is, a device that is analogous to the electric transformer. The analogy is based on the correspondence between the extensive quantities, entropy and electric charge and the intensive variables, temperature and electric potential. (Contains 1 footnote and 6 figures.)

  11. Quantum absorption refrigerator with trapped ions

    Science.gov (United States)

    Gan, Jaren; Maslennikov, Gleb; Hablützel Marrero, Roland; Ding, Shiqian; Nimmrichter, Stefan; Roulet, Alexandre; Dai, Jibo; Scarani, Valerio; Matsukevich, Dzmitry

    2017-04-01

    We report on an experimental realization of a quantum absorption refrigerator in a system of the three trapped 171Yb+ ions. The normal modes of motion are coupled by a trilinear Hamiltonian a† bc + h . c . and represent ``hot'', ``work'' and ``cold'' bodies of the refrigerator. We investigate the equilibrium properties of the refrigerator, and demonstrate the absorption refrigeration effect with the modes being prepared in thermal states. We also investigate the coherent dynamics and steady state properties of such a system away from equilibrium operation. We compare the cooling capabilities of thermal versus squeezed thermal states prepared in the work mode as a quantum resource for cooling. Finally, we exploit the coherent dynamics of the system and demonstrate single-shot cooling in the refrigerator. By stopping the evolution in the right moment, we show a significant advantage in cooling as compared to both the steady state and equilibrium performance. This research is supported by the National Research Foundation, Prime Minister's Office, Singapore and the Ministry of Education, Singapore under the Research Centres of Excellence programme.

  12. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-02-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed

  13. THE STIRLING GAS REFRIGERATING MACHINE MECHANICAL DESIGN IMPROVING

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2016-06-01

    Full Text Available To improve the mechanical design of the piston Stirling gas refrigeration machine the structural optimization of rotary vane Stirling gas refrigeration machine is carried out. This paper presents the results of theoretical research. Analysis and prospects of rotary vane Stirling gas refrigeration machine for domestic and industrial refrigeration purpose are represented. The results of a patent search by mechanisms of transformation of rotary vane machines are discussed.

  14. Comparative study of vapour compression, thermoelectric and absorption refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Bansal, P.K.; Martin, A. [Auckland Univ., Dept. of Mechanical Engineering, Auckland (New Zealand)

    2000-07-01

    This paper investigates the performance characteristics of the three domestic refrigerators, namely the vapour compression (VC), the thermoelectric (TE) and the absorption refrigeration (AR). AR and TE refrigerators are the result of research and development in refrigeration systems in the quest to find a cooling system which does not use any refrigerant that damages the ozone layer. Three refrigerators of similar capacity (about 50l) were compared for their usage in the hotel industry in view of their energy efficiency, noise produced and cost (owning as well as running). It was found that the VC refrigerator consumed the least energy, was least costly but was the noisiest. The absorption refrigerator was the quietest of the three but was the least energy efficient and most expensive. The thermoelectric refrigerator was the costliest, nearly as noisy as the VC but was a little less energy efficient than the absorption refrigerator. (Author)

  15. Simulation of absorption refrigeration system for automobile application

    OpenAIRE

    Ramanathan Anand; Gunasekaran Prabhakaran

    2008-01-01

    An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixtu...

  16. Simulation of absorption refrigeration system for automobile application

    Directory of Open Access Journals (Sweden)

    Ramanathan Anand

    2008-01-01

    Full Text Available An automotive air-conditioning system based on absorption refrigeration cycle has been simulated. This waste heat driven vapor absorption refrigeration system is one alternate to the currently used vapour compression refrigeration system for automotive air-conditioning. Performance analysis of vapor absorption refrigeration system has been done by developing a steady-state simulation model to find the limitation of the proposed system. The water-lithium bromide pair is used as a working mixture for its favorable thermodynamic and transport properties compared to the conventional refrigerants utilized in vapor compression refrigeration applications. The pump power required for the proposed vapor absorption refrigeration system was found lesser than the power required to operate the compressor used in the conventional vapor compression refrigeration system. A possible arrangement of the absorption system for automobile application is proposed.

  17. Solar heating and cooling with absorption refrigeration

    OpenAIRE

    Montlló Casabayó, Gerard

    2010-01-01

    This project is focused on solar heating and cooling installations that use solar thermal energy to produce heat for domestic hot water or space heating, and cooling for air conditioning through absorption refrigeration cycle. The first part of the project is a literature review of said technology. The main components of such installations are described and results and conclusions from existing installations are reviewed. The second part is focused on designing, modelling and simula...

  18. Thermodynamic performances of [mmim]DMP/Methanol absorption refrigeration

    Science.gov (United States)

    Chen, Wei; Liang, Shiqiang; Guo, Yongxian; Cheng, Keyong; Gui, Xiaohong; Tang, Dawei

    2012-12-01

    In order to study the theoretical cycle characteristic of [mmim]DMP (1-methyl-3-methylimidazolium dimethylphosphate) /methanol absorption refrigeration, the modified UNIFAC group contribution model and the Wilson model are established through correlating the experimental vapor pressure data of [mmim]DMP/methanol at T=280˜370 K and methanol mole fraction x= 0.529˜0.965. Thermodynamic performances of absorption refrigeration utilizing [mmim]DMP/methanol, LiBr/H2O and H2O/NH3 are investigated and compared with each other under the same operating conditions. From the results, some conclusions are obtained as follows: 1) the circulation ratio of the [mmim]DMP /methanol absorption refrigeration is higher than that of the LiBr/H2O absorption refrigeration, but still can be acceptable and tolerable. 2) The COP of the [mmim]DMP/methanol absorption refrigeration is smaller than that of the LiBr/H2O absorption refrigeration, while it is higher than that of the H2O/NH3 absorption refrigeration under most operating conditions. 3) The [mmim]DMP/methanol absorption refrigeration are still available with high COP when the heat source temperature is too high to drive LiBr/H2O absorption refrigeration.

  19. Exergy-analysis based comparative study of absorption refrigeration and electric compression refrigeration in CCHP systems

    International Nuclear Information System (INIS)

    Li, Yajun; Hu, Rentian

    2016-01-01

    Highlights: • Performs a comparative study between two different refrigeration systems in CCHP. • Focuses on the impact of steam transport distance on energy and exergy efficiency. • The choice of refrigeration system in CCHP under given conditions is presented. - Abstract: Fueling with natural gas, combined cooling, heating and power (CCHP) system is expected to be widely applied in China, for its potential on energy efficiency and CO 2 emissions reduction. In the design of CCHP, the choice of refrigeration system is now a hot topic because it greatly influences the performance. This paper has made a comparative study between the absorption refrigeration system and electric compression refrigeration system, in terms of exergy efficiency of refrigeration system in CCHP and energy efficiency of CCHP. A GE 9171E gas–steam combined cycle based CCHP system is chosen and analyzed as an example. The comparative study shows that the distance between power station and refrigeration station, namely the steam transport distance, has an effect on the performances of absorption refrigeration system in CCHP and CCHP based on it. As a result, under the conditions studied, absorption refrigeration is more effective when the distance is shorter than 5 km, and if longer than 9.3 km, electric compression refrigeration is a better choice. With distance between 5 and 9.3 km, the kind of refrigeration should depend on specific conditions. This paper does make important guiding significance for the choice of refrigeration system in the design of CCHP.

  20. Influence of Refrigerant Mass Fraction in the Performance of an Ammonia Absorption Refrigerator

    Science.gov (United States)

    Takeshita, Keisuke; Amano, Yoshiharu; Hashizume, Takumi; Takei, Toshitaka; Tomizawa, Masao

    The performance of the rectifying column affects the coefficient of performance (COP) of an ammonia absorption refrigerator. Ammonia mass fraction of refrigerant is one of the key parameters indicating the performance of the rectifying column. We propose a method to estimate the refrigerant mass fraction with mass and energy balance equations around the separator at the inlet of the evaporator, and describe the results of experiments which measured the refrigerant mass fraction by sampling from the refrigerant receiver. Throughout these investigations, the refrigerant mass fraction turned out to be lower than the expected value calculated from the condition of dry-saturated vapor at the top of the rectifying column. The refrigerant mass fraction can be estimated within an accuracy of 0.3% by the estimation method based on mass and energy balance equations.

  1. Industrial ammonia absorption refrigeration plants in combination with gas engines; Groupes de refrigeration industriels a absorption d'ammoniac combines avec des moteurs a gaz

    Energy Technology Data Exchange (ETDEWEB)

    Bassols, J. [Colibri bv (Netherlands); Sahu, J. [Gas Natural SDG, S.A. (Spain)

    2000-07-01

    In many industrial sectors, co-generation systems with gas turbines or engines and ammonia absorption refrigeration plants are being introduced for the simultaneous production of electricity and refrigeration in order to meet the energy requirements inherent to each process and to reduce the operating costs. The different possibilities to link the absorption refrigeration plant to the cogeneration system and to the consumers are described. Different examples of realised projects are used to illustrate the different systems. Despite the fact that, compared to compression refrigeration machines, ARP's have lower COP (coefficient of performance) and higher investment costs, the advantage of using thermal energy as a driving energy instead of electricity makes the combination cogeneration-ARP very attractive. The plants can easily be integrated into an existing refrigeration installation. The full automatic control systems provide a trouble-free operation. Because most of the components of an ARP are heat exchangers, the plants only need little maintenance and are not susceptible to trouble. For their maintenance, no special knowledge is necessary. Plants working with NH{sub 3}-H{sub 2}O use ammonia as a refrigerant, which is a natural and environment-friendly fluid. (authors)

  2. COMPARISON OF ENERGY AND EXERGY EFFICIENCIES OF ABSORPTION REFRIGERATION SYSTEM WITH MECHANICAL COMPRESSION REFRIGERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Gülay YAKAR

    2005-02-01

    Full Text Available In this study, energy and exergy analysis of absorption refrigeration system using LiBr- water and mechanical compression refrigeration system using R134-a were performed at different evaporation temperatures. The results are presented in tables and figures.

  3. Evolution of absorption machines; Evolution des machines a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soide, I.; Klemsdal, E. [Gaz de France (GDF), 75 - Paris (France); Le Goff, P.; Hornut, J.M. [LSGC-ENSIC, 54 - Nancy (France)

    1997-12-31

    Most of todays absorption air-conditioning machineries use the lithium bromide-water pair. The most performing can operate at a 150-160 deg. C, the temperature being limited by the corrosion resistance of metals with respect to LiBr solutions. Also, there is a revival of interest for water-ammonia systems. These systems require the use of a rectification column which reduces the coefficient of performance. Higher thermal performances are reached with hydrocarbon pairs and ternary mixtures (water-methanol-LiBr etc..). This paper presents different schemes of refrigerating heat pumps based on these different systems. (J.S.)

  4. Analysis of crystallization risk in double effect absorption refrigeration systems

    International Nuclear Information System (INIS)

    Garousi Farshi, L.; Seyed Mahmoudi, S.M.; Rosen, M.A.

    2011-01-01

    Absorption refrigeration systems are an alternative to vapor compression ones in cooling and refrigeration applications. In comparison with single effect absorption units, double effect systems have improved performance. Also, they are more available commercially than the other multi effect absorption cycles. An important challenge in the operation of such systems is the possibility of crystallization within them. This is especially true in developing air-cooled absorption systems, which are attractive because cooling tower and associated installation and maintenance issues can be avoided. Therefore, distinguishing the working conditions that may cause crystallization can be useful in the design and control of these systems. In this paper a computational model has been developed to study and compare the effects of operating parameters on crystallization phenomena in three classes of double effect lithium bromide-water absorption refrigeration systems (series, parallel and reverse parallel) with identical refrigeration capacities. It is shown that the range of operating conditions without crystallization risks in the parallel and the reverse parallel configurations is wider than those of the series flow system. - Highlights: → We study crystallization of double effect absorption refrigeration systems. → We consider series, parallel and reverse parallel cycles. → We study the effect of operating conditions on crystallization. → We choose optimum distribution ratio for parallel and reverse parallel systems. → Crystallization possibility is low in parallel and reverse parallel cycles.

  5. An absorption-diffusion refrigerator operated by solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Sabry, T.I.; Hanafy, A.E.; Klup, A.M.A. [Menoufla Univ. (Egypt)

    1993-12-31

    The design of a commercially available vapor absorption electrical refrigerator was changed to make it suitable for running on solar energy. The refrigerator was attached to a thermo-siphonic flat-plate solar oil heating system with small tank-collector volume ratio collector to supply heat to the generator of the refrigerator. The test results revealed that the minimum evaporator temperature was around 2 C. The designed solar heating system was suitable for the operation of the refrigerator by solar energy. From the analysis of the operation of the refrigerator by both electrical as well as solar energy, it was found that the ambient temperature is a dominant factor affecting the system performance. (Authors). 10 refs., 14 figs., 1 tab.

  6. Heat exchanger bypass system for an absorption refrigeration system

    Science.gov (United States)

    Reimann, Robert C.

    1984-01-01

    A heat exchanger bypass system for an absorption refrigeration system is disclosed. The bypass system operates to pass strong solution from the generator around the heat exchanger to the absorber of the absorption refrigeration system when strong solution builds up in the generator above a selected level indicative of solidification of strong solution in the heat exchanger or other such blockage. The bypass system includes a bypass line with a gooseneck located in the generator for controlling flow of strong solution into the bypass line and for preventing refrigerant vapor in the generator from entering the bypass line during normal operation of the refrigeration system. Also, the bypass line includes a trap section filled with liquid for providing a barrier to maintain the normal pressure difference between the generator and the absorber even when the gooseneck of the bypass line is exposed to refrigerant vapor in the generator. Strong solution, which may accumulate in the trap section of the bypass line, is diluted, to prevent solidification, by supplying weak solution to the trap section from a purge system for the absorption refrigeration system.

  7. The refrigeration of large superconducting machines

    International Nuclear Information System (INIS)

    Gistau, G.

    1991-01-01

    The large scale superconducting devices which are now in operation for deviation of heavy particles, acceleration of light particles or plasma confinement need very large powers of refrigeration. After a short survewing of the different functions of refrigerators and the special requirements for large units, the paper describes some existing or envisaged cooling systems which have an equivalent cooling power in the range of 5kW at 4.5 K [fr

  8. Transient behaviour of an adsorption refrigerator. Experimental study of the alcohol/activated carbon system; Comportement transitoire d`une machine frigorifique a absorption. Etude experimentale du systeme alcool / charbon actif

    Energy Technology Data Exchange (ETDEWEB)

    Luo, L. [Centre National de la Recherche Scientifique (CNRS), 54 - Nancy (France). Lab. des sciences du genie chimique; Feidt, M. [Nancy-1 Univ., 54 - Vandoeuvre-les-Nancy (France)

    1997-03-01

    The objective of this article is to present an experimental study of an adsorption refrigerator, accounting for the transient phenomena in each component of the machine, in particular in the adsorber. The couples adsorbate/adsorbent investigated (activated carbon/methanol or ethanol) have been chosen on the basis of an earlier comparative study. We have performed a full series of experiments to investigate the transient evolution of temperatures, pressures and the cycled mass, in a discontinuous cycle, and along the components of the refrigerating machine. The influence of various parameters is studies by varying one at a time: adsorbate/ adsorbent couple, alcohol load in adsorber, alcohol flowrate, heating power, initial desorption temperature. All these experimental observation are discussed and compared to transient models developed in a separate article. (authors) 12 refs.

  9. Experimental Investigation on an Absorption Refrigerator Driven by Solar Cells

    Directory of Open Access Journals (Sweden)

    Zi-Jie Chien

    2013-01-01

    Full Text Available This experiment is to study an absorption refrigerator driven by solar cells. Hand-held or carried in vehicle can be powered by solar energy in places without power. In the evenings or rainy days, it is powered by storage battery, and it can be directly powered by alternating current (AC power supply if available, and the storage battery can be charged full as a backup supply. The proposed system was tested by the alternation of solar irradiance 550 to 700 W/m2 as solar energy and 500ml ambient temperature water as cooling load. After 160 minutes, the proposal refrigerator can maintain the temperature at 5–8°C, and the coefficient of performance (COP of NH3-H2O absorption refrigeration system is about 0.25. Therefore, this system can be expected to be used in remote areas for refrigeration of food and beverages in outdoor activities in remote and desert areas or long-distance road transportation of food or low temperature refrigeration of vaccine to avoid the deterioration of the food or the vaccines.

  10. Performance of refrigerating machineries with new refrigerants; Performance des machines frigorifiques avec les nouveaux refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Bailly, A.; Jurkowski, R. [CIAT, 01 - Culoz (France)

    1997-12-31

    This paper reports on a comparative study of the thermal performances of different refrigerants like R-22, R-134a, R-404A and R-407C when used as possible substitutes for the HCFC22 refrigerant in a given refrigerating machinery equipped with compact high performance plate exchangers. Thermal performances are compared in identical operating conditions. The behaviour of the two-phase exchange coefficient is analyzed with respect to the different parameters. The composition of the mixture after one year of operation has been analyzed too and the influence of oil on the performances is studied. (J.S.)

  11. Performance of diffusion absorption refrigeration cycle with organic working fluids

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, A.; Jelinek, M.; Levy, A.; Borde, I. [Pearlstone Center for Aeronautical Engineering Studies, Mechanical Engineering Department, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105 (Israel)

    2009-09-15

    A diffusion absorption refrigeration (DAR) cycle is driven by heat and utilizes a binary solution of refrigerant and absorbent as working fluid, together with an auxiliary inert gas. Commercial DAR systems operate with ammonia-water solution and hydrogen or helium as the inert gas. In this work, the performance of a simplified DAR system working with an organic absorbent (DMAC - dimethylacetamide) and five different refrigerants and helium as inert gas was examined numerically, with the aim of lowering the generator temperature and system pressure along with a non-toxic refrigerant The refrigerants were: chlorodifluoromethane (R22), difluoromethane (R32), 2-chloro-1,1,1,2-tetrafluoroethane (R124), pentafluoroethane (R125) and 1,1,1,2-tetrafluoroethane (R134a). The results were compared with the performance of the same system working with ammonia-water and helium. Similar behavior was found for all systems, regarding the coefficient of performance (COP) and rich and poor solution concentrations as functions of generator temperature. It was found that typical generator temperature with the new substances was 150 C, yet lower COPs, higher evaporator temperatures and lower condensation temperature of about 40 C governed these systems. (author)

  12. 10 CFR 431.292 - Definitions concerning refrigerated bottled or canned beverage vending machines.

    Science.gov (United States)

    2010-01-01

    ... beverage vending machines. 431.292 Section 431.292 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY... Vending Machines § 431.292 Definitions concerning refrigerated bottled or canned beverage vending machines. Basic model means, with respect to refrigerated bottled or canned beverage vending machines, all units...

  13. Thermo-economic analysis of steady state waste heat recovery in data centers using absorption refrigeration

    International Nuclear Information System (INIS)

    Ebrahimi, Khosrow; Jones, Gerard F.; Fleischer, Amy S.

    2015-01-01

    Highlights: • Absorption refrigeration is powered by data center waste heat. • Waste heat from 3 to 5 server racks produces cooling for an additional rack. • An economic analysis shows the payback period can be as short as 4–5 months. - Abstract: This paper addresses the technical and economic issues associated with waste heat recovery in data centers through the use of absorption cooling machines. The theoretical possibility of utilizing the heat dissipated by a server, or a number of servers, to power an absorption system, which in turn produces cooling for other servers in the data center, is investigated. For this purpose, a steady-state thermodynamic model is developed to perform energy balance and exergy analyses for a novel configuration of an on-chip two-phase cooling system and an absorption refrigeration system. This combination is created by replacing the condenser in the on-chip cooling circuit with the generator of an absorption refrigeration cycle. The performance of the developed model in simulating both LiBr–water and water–ammonia absorption cooling systems is examined through verification of the model results against the reference data available in the literature. The verification indicates the superiority of LiBr–water absorption system for data center/server operating conditions. Therefore, a LiBr–water absorption refrigeration system is modeled in the novel combined heat recovery system. For these systems it is shown that the traditional definition for the coefficient of performance (COP) is not appropriate to evaluate the performance and, in its place, introduce a new figure of merit. Through a sensitivity analysis, the effects of server waste heat quality, server coolant type, solution peak concentration, solution heat exchanger effectiveness, evaporator temperature, and operating pressures on the performance of the novel system are investigated. Finally, using the thermodynamic model and cost information provided by the

  14. The Research on Programmable Control System of Lithium-Bromide Absorption Refrigerating Air Conditioner Based on the Network

    Directory of Open Access Journals (Sweden)

    Sun Lunan

    2016-01-01

    Full Text Available This article regard the solar lithium-bromide absorption refrigerating air conditioning system as the research object, and it was conducting adequate research of the working principle of lithium bromide absorption refrigerating machine, also it was analyzing the requirements of control system about solar energy air conditioning. Then the solar energy air conditioning control system was designed based on PLC, this system was given priority to field bus control system, and the remote monitoring is complementary, which was combining the network remote monitoring technology. So that it realized the automatic control and intelligent control of new lithium bromide absorption refrigerating air conditioning system with solar energy, also, it ensured the control system can automatically detect and adjust when the external conditions was random changing, to make air conditioning work effectively and steadily, ultimately ,it has great research significance to research the air conditioning control system with solar energy.

  15. Thermodynamic analysis of an absorption refrigeration system with ionic-liquid/refrigerant mixture as a working fluid

    International Nuclear Information System (INIS)

    Kim, Yoon Jo; Kim, Sarah; Joshi, Yogendra K.; Fedorov, Andrei G.; Kohl, Paul A.

    2012-01-01

    Thermodynamics of an ionic-liquid (IL) based absorption refrigeration system has been numerically analyzed. It provides an alternative to the normally toxic working fluids, such as the ammonia in conventional absorption systems. The use of ILs also eliminates crystallization and metal-compatibility problems of the water/LiBr system. Mixtures of refrigerants and imidazolium-based ILs are theoretically explored as the working fluid pairs in a miniature absorption refrigeration system, so as to utilize waste-heat to power a refrigeration/heat pump system for electronics cooling. A non-random two-liquid (NRTL) model was built and used to predict the solubility of the mixtures. Saturation temperatures at the evaporator and condenser were set at 25 °C and 50 °C, respectively, with the power dissipation of 100 W. Water in combination with [emim][BF 4 ] (1-ethyl-3-methylimidazolium tetrafluoroborate) gave the highest coefficient of performance (COP) around 0.9. The refrigerant/IL compatibility indicated by the circulation ratio, alkyl chain length of the IL, and thermodynamic properties of the refrigerants, such as latent heat of evaporation were proven to be important factors in determining the performance of the absorption system. The negative effect of high viscosity was mitigated by dilution of the IL with the refrigerant and the use of slightly larger microfluidic channel heat exchangers. -- Highlights: ► Mixtures of refrigerant/ionic-liquid are studied for absorption system. ► We carry out comprehensive theoretical thermodynamic analysis. ► The essential factors of refrigerant/IL affecting the performance are identified. ► Water/[emim][BF 4 ] showed the best performance of COP. ► The effects of high viscosity ILs on the system performance are not significant.

  16. The Philips stirling refrigeration machine and her applications

    Energy Technology Data Exchange (ETDEWEB)

    Van der Ster, J.

    1989-08-01

    The Stirling refrigeration machine as developed and marketed by Philips has been quite successful. About 4000 units are installed. The most important application is the production of liquid nitrogen on relatively small scale. In the fifties and sixties the main applications were found in research laboratories. Since 1970 the system became more and more used outside laboratories. Artificial insemination of cattle was a very important market, especially in third world countries. This was a positive contribution to the efforts to solve the food problem in this developing countries. 6 figs., 7 refs., 1 tab.

  17. Integration of absorption refrigeration systems into Rankine power cycles to reduce water consumption: A thermodynamic analysis

    International Nuclear Information System (INIS)

    Salgado, R.; Belmonte, J.F.; Almendros-Ibáñez, J.A.; Molina, A.E.

    2017-01-01

    A high percentage of the heat that is supplied to thermoelectric power plants is discarded to ambient and must be handled by an external cooling system. This cooling system typically consists of wet cooling towers because of the excellent thermo-physical properties of water. However, the amount of water consumed for power production has reached alarming levels in developed countries. Air-cooled heat exchangers (ACHXs) appear to be the most adequate technology to substitute for wet cooling towers, but the use of this technology has some limitations. The most important limitation is the higher condenser pressures in the cycle, which produce backpressures at the condensing turbine's exit, increases in heat rejection and losses in the net plant efficiency. This paper presents a concept for the use of ACHXs in the cooling systems of power plants using an absorption refrigeration system (ARS) as an intermediary. Heat from the steam condenser is handled by the evaporator of the ARS and “lifted” to a higher temperature level, where the ACHXs are fitted to work. The generator of the ARS is fed by the power plant itself, extracting (bleeding off) some of the steam that flows through the steam turbine at the correct pressure and temperature. - Highlights: • Integration of absorption refrigeration system into the Rankine cycle of power plant. • The absorption refrigeration system will be driven by bleeding off steam turbine. • Lift rejection temperatures to a higher level to operate with air cooled condensers. • The water savings are estimated to be in the range of 1.12–5.58 m 3 /MWh. • Studying the integration with single- and double-effect absorption machines.

  18. Analysis of an absorption/absorption–compression refrigeration system for heat sources with large temperature change

    International Nuclear Information System (INIS)

    Chen, Yi; Han, Wei; Jin, Hongguang

    2016-01-01

    Highlights: • This paper proposes an absorption/absorption–compression refrigeration system. • The temperature of the waste gas exhausted from the system is quite low. • The system cooling capacity per unit mass of flue gas is 58.95 kJ kg −1 at −15 °C. • Key parameters were investigated to provide guidance to the system optimization. - Abstract: Absorption refrigeration systems are a promising way to reduce electricity consumption in the field of refrigeration and cooling. To improve the thermal energy utilization performance of the absorption refrigeration system, an absorption/absorption–compression refrigeration system with a large working range is proposed in this paper. The new system consists of a conventional single-effect absorption subcycle and an absorption–compression refrigeration subcycle, and they share the condenser, evaporator, absorber and some other relative components. The temperature of the waste gas exhausted from the system can be 35 °C lower than that of the waste gas from a traditional, single-effect absorption refrigeration system. For the proposed system, the cooling capacity per unit mass of flue gas reaches 58.95 kJ kg −1 when the evaporation temperature is −15 °C, which is 28.21% higher than that of the single-effect absorption refrigeration system. The exergy efficiency of the proposed system is as high as 25.94%. To indicate the direction of system optimization, the new system is further studied using a parametric analysis. The new absorption/absorption–compression refrigeration system provides a promising way to efficiently utilize heat sources with large temperature change or multiple heat sources with different temperatures.

  19. Detailed thermodynamic analysis of a diffusion-absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Taieb, Ahmed; Mejbri, Khalifa; Bellagi, Ahmed

    2016-01-01

    This paper proposes an advanced simulation model for a Diffusion-Absorption Refrigerator DAR using ammonia/water/hydrogen as working fluids, and developed to describe and predict the behavior of the device under different operating conditions. The system is supposed to be cooled with ambient air and actuated with solar hot water available at 200 °C. The DAR is first simulated for a set of basic data; a COP of 0.126 associated to a cooling capacity of 22.3 W are found. Basing on the obtained results an exergetic analysis of the system is performed which shows that the rectifier contribution to the exergy destruction is the most important with 34%. In a second step, the thermal capacities of all heat exchangers of the DAR are evaluated and the mathematical model so modified that the calculated capacities are now used as input data. A parametric study of the cycle is then carried out. The COP is found to exhibit a maximum when the heat supplied to the boiler or to the bubble pump is varied. Similar behavior is observed for variable submergence ratio. It is further noted that the COP is very sensitive to the ambient air temperature and to the absorber efficiency. - Highlights: • A detailed model of a Diffusion Absorption is developed and simulated. • Irreversibility of each component of the cycle is examined. • A modified model based on thermal capacity of components of the DAR is elaborated. • System performance is calculated over a series of practical operating conditions.

  20. Redesign 3 R Machine as a Refrigerant Waste Treatment Alternative in Environmental Rescue

    Science.gov (United States)

    Negara, I. P. S.; Arsawan, I. M.

    2018-01-01

    Cooling machine technologies really affect nowadays’ modern life, not only limited in enhancement of life quality and comfort, but it has also reached the essential things of humans’ life supporter (Arora, 2001). Cooling machine technologies have direct contribution toward environmental damage such as depletion of ozone layer and global warming through synthetic refrigerant waste and leakage (CFC and HFC) to environment. The refrigerant release to the environment is 60% of the service sector. Destructive characteristics of ozone possessed by CFC were first proposed by Rowland and Molina which were then supported by yard measurement. It is estimated that ozone layer damage occurs for about 3% every decade. The ozone layer located in the stratosphere is functioned to prevent ultraviolet-B ray from entering into earth surface. This Ultraviolet-B is suspected to be the cause of health problem for humans and disorder for plants on earth. As for the purpose of this research is to obtain a product design of refrigerant waste processing system (recovery and recycle refrigerant) as well as to acknowledge the work method (COP) of cooling machines that use CFC refrigerant (R-12) as the result of recovery and recycle compared to CFC refrigerant (R-12)/pure R134a. One method that can be used is by redesigning existing equipment namely 3R machine that cannot be used anymore thus it can be reused. This research will be conducted through modifying the existing 3R machine therefore it can be reused and be easily operated as well as doing the maintenance, after that the refrigerant as the result of recovery will be tried on a refrigeration system and a test of refrigeration system work method will be conducted by using the refrigerant recycle product which is obtained and compared with the work method of the one with pure refrigeration.The result has been achieved that the redesign product of refrigerant waste processing equipment can be reused and able to perform the recovery

  1. Parametric analysis for a new combined power and ejector-absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Jiangfeng; Dai Yiping; Zhang Taiyong; Ma Shaolin

    2009-01-01

    A new combined power and ejector-absorption refrigeration cycle is proposed, which combines the Rankine cycle and the ejector-absorption refrigeration cycle, and could produce both power output and refrigeration output simultaneously. This combined cycle, which originates from the cycle proposed by authors previously, introduces an ejector between the rectifier and the condenser, and provides a performance improvement without greatly increasing the complexity of the system. A parametric analysis is conducted to evaluate the effects of the key thermodynamic parameters on the cycle performance. It is shown that heat source temperature, condenser temperature, evaporator temperature, turbine inlet pressure, turbine inlet temperature, and basic solution ammonia concentration have significant effects on the net power output, refrigeration output and exergy efficiency of the combined cycle. It is evident that the ejector can improve the performance of the combined cycle proposed by authors previously.

  2. Experimental investigation of integrated refrigeration system (IRS) with gas engine, compression chiller and absorption chiller

    International Nuclear Information System (INIS)

    Sun, Z.G.

    2008-01-01

    An integrated refrigeration system (IRS) with a gas engine, a vapor-compression chiller and an absorption chiller is set up and tested. The vapor-compression refrigeration cycle is operated directly by the gas engine. The waste heat from the gas engine operates the absorption refrigeration cycle, which provides additional cooling. The performance of the IRS is described. The cooling capacity of the IRS is about 596 kW, and primary energy ratio (PER) reaches 1.84 at air-conditioning rated conditions. The refrigerating capacity of the prototype increased and PER of prototype decreased with the increase of the gas engine speed. The gas engine speed was preferably regulated at part load condition in order to operate the prototype at high-energy efficiency. The refrigerating capacity and PER of the prototype increased with the increase of the outlet temperature of chilled water or the decrease of the inlet temperature of cooling water. The integrated refrigeration chiller in this work saves running costs as compared to the conventional refrigeration system by using the waste heat

  3. Triple-effect absorption refrigeration system with double-condenser coupling

    Science.gov (United States)

    DeVault, Robert C.; Biermann, Wendell J.

    1993-01-01

    A triple effect absorption refrigeration system is provided with a double-condenser coupling and a parallel or series circuit for feeding the refrigerant-containing absorbent solution through the high, medium, and low temperature generators utilized in the triple-effect system. The high temperature condenser receiving vaporous refrigerant from the high temperature generator is double coupled to both the medium temperature generator and the low temperature generator to enhance the internal recovery of heat within the system and thereby increase the thermal efficiency thereof.

  4. Thermo-economic optimization of an endoreversible four-heat-reservoir absorption-refrigerator

    International Nuclear Information System (INIS)

    Qin Xiaoyong; Chen Lingen; Sun Fengrui; Wu Chih

    2005-01-01

    Based on an endoreversible four-heat-reservoir absorption-refrigeration-cycle model, the optimal thermo-economic performance of an absorption-refrigerator is analyzed and optimized assuming a linear (Newtonian) heat-transfer law applies. The optimal relation between the thermo-economic criterion and the coefficient of performance (COP), the maximum thermo-economic criterion, and the COP and specific cooling load for the maximum thermo-economic criterion of the cycle are derived using finite-time thermodynamics. Moreover, the effects of the cycle parameters on the thermo-economic performance of the cycle are studied by numerical examples

  5. Optimization of a solar driven absorption refrigerator in the transient regime

    International Nuclear Information System (INIS)

    Hamed, Mouna; Fellah, Ali; Ben Brahim, Ammar

    2012-01-01

    Highlights: ► Dynamic behavior of a solar absorption refrigerator endoreversible model. ► Using the principles of classical thermodynamics, mass and heat transfers. ► Minimizing heat exchange time to reach maximum performances. ► Major influence of the collector temperature on the model’s characteristics. ► Analogous effects of both the thermal load and the thermal conductance. -- Abstract: This contribution deals with the theoretical study in dynamic mode of an absorption refrigerator endoreversible model. The system is a cold generating station driven by solar energy. The main elements of the cycle are a refrigerated space, an absorption refrigerator and a solar collector form. A mathematical model is developed. It combines the classical thermodynamics and mass and heat transfers principles. The numerical simulation is made for different operating and conceptual conditions. A global minimizing time optimization is performed in view to reach maximum performances. Appropriate dimensionless groups are defined. The results are presented in normalized charts for general applications. The collector temperature presents major influence on the conceptual and functional characteristics compared to the stagnation temperature influence. On the other hand the thermal load in the refrigerated space and the thermal conductance of the walls has analogous effects, therefore important to be considered in actual design. As a result, the model is expected to be a useful tool for simulation, design, and optimization of solar collector based energy systems.

  6. Application of waste heat powered absorption refrigeration system to the LNG recovery process

    Energy Technology Data Exchange (ETDEWEB)

    Kalinowski, Paul; Hwang, Yunho; Radermacher, Reinhard [Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742 (United States); Al Hashimi, Saleh; Rodgers, Peter [The Petroleum Institute, Abu Dhabi (United Arab Emirates)

    2009-06-15

    The recovery process of the liquefied natural gas requires low temperature cooling, which is typically provided by the vapor compression refrigeration systems. The usage of an absorption refrigeration system powered by waste heat from the electric power generating gas turbine could provide the necessary cooling at reduced overall energy consumption. In this study, a potential replacement of propane chillers with absorption refrigeration systems was theoretically analyzed. From the analysis, it was found that recovering waste heat from a 9 megawatts (MW) electricity generation process could provide 5.2 MW waste heat produced additional cooling to the LNG plant and save 1.9 MW of electricity consumption. Application of the integrated cooling, heating, and power is an excellent energy saving option for the oil and gas industry. (author)

  7. Geothermal absorption refrigeration for food processing industries. Final report, December 13, 1976--November 13, 1977

    Energy Technology Data Exchange (ETDEWEB)

    Harris, R.L.; Olson, G.K.; Mah, C.S.; Bujalski, J.H.

    1977-11-01

    The first step in the economic analysis of the integration of geothermally powered absorption refrigeration into a food processing plant was an evaluation of the potential geothermal sites in the Western United States. The evaluation covered availability of raw materials, transportation, adequate geothermal source, labor, and other requirements for food processing plants. Several attractive geothermal sites were identified--Raft River, Idaho; Sespe Hot Springs, California; Vale Hot Springs, Oregon; Weisler-Crane Creek, Idaho; Cosco Hot Springs, California; and the Imperial Valley, California. The most economically attractive food processing industry was then matched to the site based on its particular energy, raw material, and transportation requirements. The more promising food processors identified were for frozen potato or vegetable products, freeze-dried products, and meat processing. For the refrigeration temperature range of +32/sup 0/F to -40/sup 0/F and geothermal temperature range of 212/sup 0/F to 300/sup 0/F, an absorption refrigeration system had to be identified, designed, and evaluated. Both the conventional ammonia/water and an organic absorption refrigeration system using monochlorodifluoromethane (R-22) as the refrigerant and dimethyl formamide (DMF) as the absorbent were studied. In general, only a 60/sup 0/F to 100/sup 0/F temperature drop would be effectively used for refrigeration leaving the remainder of the allowable temperature drop available for other use. The economic evaluation of the geothermal system installed in a food processing plant required the comparison of several principal alternatives. These alternatives were evaluated for three different food processing plants located at their optimum geothermal site: a forzen potato product processing plant located at Raft River, Idaho; a freeze-dried product plant located at Sespe Hot Springs, California; a beef slaughter operation located in the Imperial Valley of California. (JGB)

  8. Industrial refrigeration by absorption/compression; Refrigeracion industrial por absorcion/compresion

    Energy Technology Data Exchange (ETDEWEB)

    Ayala Delgado, Ramon; Heard, Christopher Lionel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The use of the absorption/compression refrigeration in the industrial area is analyzed. It is estimated than in Mexico 50% of the food is wasted for lack of refrigeration in the producing centers and by the inefficient distribution system, as well as for the hot climate. The functioning of the absorption refrigeration and the hybrid system absorption/compression which can operate with the two thermodynamic cycles in variable proportions, depending on the specific application, looking for operational advantages and energy efficiency is described. This type of technology could be applied in Mexico due to the lack of industrial refrigeration and to the need of substituting compressors in some companies which have up to 20 years of use [Espanol] Se analiza el uso de la refrigeracion por absorcion/compresion en el area industrial. En Mexico se estima que se desperdicia el 50% de los alimentos por falta de refrigeracion en los centros productores y por el deficiente sistema de distribucion, asi como por el clima calido. Se describe el funcionamiento de la refrigeracion por absorcion y la refrigeracion por absorcion/compresion o sistema hibrido, el cual puede funcionar con los dos tipos de ciclos termodinamicos, en proporciones variables, dependiendo de la aplicacion especifica, buscando ventajas de operacion y eficiencia energetica. Este tipo de tecnologia podria aplicarse en Mexico debido a la falta de refrigeracion industrial y a la necesidad de sustituir compresores en algunas empresas los cuales tienen hasta 20 anos de uso

  9. Numerical investigation of refrigeration machine compressor operation considering single-phase electric motor dynamic characteristics

    Science.gov (United States)

    Baidak, Y.; Smyk, V.

    2017-08-01

    Using as the base the differential equations system which was presented in relative units for generalized electric motor of hermetic refrigeration compressor, mathematical model of the software for dynamic performance calculation of refrigeration machine compressors drive low-power asynchronous motors was developed. Performed on its ground calculations of the basic model of two-phase electric motor drive of hermetic compressor and the proposed newly developed model of the motor with single-phase stator winding, which is an alternative to the industrial motor winding, have confirmed the benefits of the motor with innovative stator winding over the base engine. Given calculations of the dynamic characteristics of compressor drive motor have permitted to determine the value of electromagnetic torque swinging for coordinating compressor and motor mechanical characteristics, and for taking them into consideration in choosing compressor elements construction materials. Developed and used in the process of investigation of refrigeration compressor drive asynchronous single-phase motor mathematical and software can be considered as an element of computer-aided design system for design of the aggregate of refrigeration compression unit refrigerating machine.

  10. Copper conduction precooling of helium refrigerant in rotating superconducting machines

    International Nuclear Information System (INIS)

    Haseler, L.E.; Scurlock, R.G.; Thornton, G.K.

    1976-01-01

    In relation to the refrigeration of rotating superconducting machinery, solutions are given for the compressible flow of helium in thermally conducting ducts which are rotating about an axis perpendicular to their length. If the flow were isentropic, centrifugal compression would cause the temperature of the helium to rise to unacceptable values: flow in a duct with thermally conducting walls will reduce this temperature rise. Practical considerations are examined for using such a thermal shunt made of copper to produce substantial reductions in this temperature rise. (author)

  11. Using waste heat of ship as energy source for an absorption refrigeration system

    International Nuclear Information System (INIS)

    Salmi, Waltteri; Vanttola, Juha; Elg, Mia; Kuosa, Maunu; Lahdelma, Risto

    2017-01-01

    Highlights: • A steady-state thermodynamic model is developed for absorption refrigeration in a ship. • Operation profile of B.Delta37 bulk carrier is used as an initial data. • Suitability of water-LiBr and ammonia-water working pairs were validated. • Coefficient of performance (COP) was studied in ISO and tropical conditions. • Estimated energy savings were 47 and 95 tons of fuel every year. - Abstract: This work presents a steady-state thermodynamic model for absorption refrigeration cycles with water-LiBr and ammonia-water working pairs for purpose of application on a ship. The coefficient of performance was studied with different generator and evaporator temperatures in ISO and tropical conditions. Absorption refrigeration systems were examined using exhaust gases, jacket water, and scavenge air as energy sources. Optimal generator temperatures for different refrigerant temperatures were found using different waste heat sources and for the absorption cycle itself. Critical temperature values (where the refrigeration power drops to zero) were defined. All of these values were used in order to evaluate the cooling power and energy production possibilities in a bulk carrier. The process data of exhaust gases and cooling water flows in two different climate conditions (ISO and tropical) and operation profiles of a B. Delta37 bulk carrier were used as initial data in the study. With the case ship data, a theoretical potential of saving of 70% of the electricity used in accommodation (AC use) compressor in ISO conditions and 61% in tropical conditions was recognized. Those estimates enable between 47 and 95 tons of annual fuel savings, respectively. Moreover, jacket water heat recovery with a water-LiBr system has the potential to provide 2.2–4.0 times more cooling power than required during sea-time operations in ISO conditions, depending on the main engine load.

  12. Investigation of an experimental ejector refrigeration machine operating with refrigerant R245fa at design and off-design working conditions. Part 1. Theoretical analysis

    KAUST Repository

    Shestopalov, K.O.

    2015-07-01

    © 2015 Elsevier Ltd and IIR.All rights reserved. The ejector refrigeration machine (ERM) offers several advantages over other heat-driven refrigeration machine, including simplicity in design and operation, high reliability and low installation cost, which enable its wide application in the production of cooling. In this paper the theoretical analysis of ejector design and ejector refrigeration cycle performance is presented. It is shown that ERM performance characteristics depend strongly on the operating conditions, the efficiency of the ejector used, and the thermodynamic properties of the refrigerant used. A 1-D model for the prediction of the entrainment ratio ω, and an optimal design for ejectors with cylindrical and conical-cylindrical mixing chambers are presented in this paper. In order to increase ERM performance values, it is necessary first of all to improve the performance of the ejector.

  13. Investigations into solar powered diffusion-absorption cooling machines

    OpenAIRE

    Jakob, Uli

    2005-01-01

    Solar thermal driven or assisted absorption cooling machines are gaining increasing importance due to the continually growing demand for airconditioning in domestic housing as well as office and hotel buildings. Presently there are no thermally driven absorption cooling machines available on the market that can provide a smaller cooling capacity than 10kW for cooling buildings. For this reason, two single-effect solar heated ammonia/water (NHJlH20) Diffusion-Absorption Co...

  14. A LiBr-H2O Absorption Refrigerator Incorporating a Thermally Activated Solution Pumping Mechanism

    OpenAIRE

    Ian W. Eames

    2017-01-01

    This paper provides an illustrated description of a proposed LiBr-H2O vapour absorption refrigerator which uses a thermally activated solution pumping mechanism that combines controlled variations in generator vapour pressure with changes it produces in static-head pressure difference to circulate the absorbent solution between the generator and absorber vessels. The proposed system is different and potentially more efficient than a bubble pump system previously proposed and avoids the need f...

  15. Investigation Regarding the Operation of Absorption Refrigerator using Waste Heat of Phosphoric acid Fuel Cell

    Science.gov (United States)

    Kimijima, Shinji; Waragai, Shisei; Uekusa, Tsuneo; Kawai, Sunao

    Fuel cells are emerging as a major power generation system that is suitable for distributed power generation from a view point of high efficiency and low pollutant emission, In order to develop high efficiency system, it is indispensable to take into consideration effective use of waste heat recovered from power generation unit. And the system design that is based on the characteristics of individual component and all of the system is significant. In this report, characteristics of phosphoric acid fuel cell (PAFC) cogeneration system, especially waste heat recovery from PAFC cell stack and exhaust gas is discussed, and operation of absorption refrigerator using waste heat of PAFC are investigated. PAFC cogeneration test facility is constructed, power generation and waste heat recovery experiment is carried out, and system performance is evaluated, As a result, beneficial knowledge are obtained as follows: It is clarified that the cell stack waste heat is dominant for the exhaust gas heat recovery characteristics, and the cooling performance of absorption refrigerator in partial load operation of PAFC. And, the effect of cooling water temperature on the performance of waste heat recovery and absorption refrigerator is obtained.

  16. Dynamic investigation of the diffusion absorption refrigeration system NH3-H2O-H2

    Directory of Open Access Journals (Sweden)

    Mohamed Izzedine Serge Adjibade

    2017-09-01

    Full Text Available This paper reports on a numerical and experimental study of a diffusion absorption refrigerator. The performance of the system is examined by computer simulation using MATLAB software and Engineering Equations Solver. A dynamic model is developed for each component of the system and solved numerically in order to predict the transient state of the diffusion absorption refrigeration. The experiment set included 0.04 m3 commercial absorption diffusion refrigerator working with the ammonia-water-hydrogen (NH3-H2O-H2 solution. The transient numerical results were validated with the experimental data. The investigations are focused on the dynamic profile of the temperature of each component. The results obtained agree with the experiment; the relative error between numerical and experimental models doesn’t exceed 15% for all temperatures of each component. The increase of the average ambient temperature from 23.04 °C to 32.56 °C causes an increase of the condensation temperature from 29.46 °C to 37.51 °C, and the best evaporation temperature obtained was 3 °C, with an ambient temperature of 23.04 °C. The results show that a minimum starting temperature of 152 °C and 63.8 W electric power are required to initiate the decrease of evaporation temperature.

  17. Performance analysis and evaluation of a commercial absorption-refrigeration water-ammonia (ARWA) system

    Energy Technology Data Exchange (ETDEWEB)

    Darwish, N.A.; Al-Hashimi, S.H.; Al-Mansoori, A.S. [The Chemical Engineering Program, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates)

    2008-11-15

    The Robur absorption-refrigeration water-ammonia (ARWA) system is analyzed using Aspen Plus flowsheet simulator. The results are compared with experimental and some manufacturer data reported in the open literature. Among performance parameters analyzed are coefficient of performance (COP), heat duties of the evaporator, absorber, and the condenser, refrigerant concentration in the weak and strong solution, and flow rates of the weak solution and the flow rate of refrigerant passing through the evaporator. In general, a very good agreement between the simulator's results and the experimental measurements was found. Also, results obtained for the effect of separator (input) heat duty on the COP agree well with the reported experimental data with a maximum percentage deviation of 1.8%. Efficiency of the separator in splitting off the refrigerant at the column top is shown to be of crucial importance; COP increased by 15% in going from 1 to 5 theoretical equivalent mass transfer stages in the separator. Some innovative modifications to Robur cycle aimed at enhancing the separator operation have shown a promising improvement in the COP. In particular, introducing a throttling process directly before the separator can alleviate the separator heat load and enhance the COP by up to 20%. Use of stripping gas injected at the bottom of the boiler is another strategy that has been investigated in this work. (author)

  18. New Solutions for Solar Absorption Refrigeration Systems and Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2017-04-01

    Full Text Available The mission of the research includes the following objectives: the development of new circuit decisions for the alternate refrigerating systems based on the use of an open absorptive circuit and on the use of solar energy for absorbent solution regeneration; an assessment of the energy and environmental characteristics of the developed systems; obtaining of the experimental data for an assessment of the principal capabilities of the proposed new solar air-conditioning systems. The multistage principle of the creation of drying and cooling contours with the increase of concentration of absorbent on cooler steps is offered. The absorber with internal steam cooling allowing the improvement of the scheme of the alternate refrigerating system is developed. On the basis of the obtained experimental data the analysis of the main opportunities of the developed solar air-conditioning systems was made which showed that the created systems: provide the required comfortable parameters indoors without engaging of traditional refrigerating technics; allow to use only one - or two-stage option of refrigerating system for application in the conditions of Ukraine and of Europe. In comparison with traditional vapor-compression systems, the developed solar systems provide the considerable decrease in energy consumption (to 30%, their use leads to the decrease of exhaustion of natural resources, influences less global climate change.

  19. A study of wear in refrigerating machines using thin layer activation

    International Nuclear Information System (INIS)

    Hammer, P.; Eichhorn, K.; Eifrig, C.

    1986-01-01

    Wear is studied in a ball-and-socket joint of a newly developed refrigerating machine. Using deuteron activation a 15 μm deep Co-57 layer is generated at the ring-shaped friction area in the steel socket of the joint. The measurement of the Co-57 intensity of the wear particles held back on an oil filter provides information about the wear rate of the socket during machine operation. The measurement of the Co-57 contaminations occuring in the individual parts of the machine at the end of the test gives information about the distribution of the wear particles in the machine and about the material transfer in the ball-and-socket joint. (author)

  20. Quantum and classical dynamics of a three-mode absorption refrigerator

    Directory of Open Access Journals (Sweden)

    Stefan Nimmrichter

    2017-12-01

    Full Text Available We study the quantum and classical evolution of a system of three harmonic modes interacting via a trilinear Hamiltonian. With the modes prepared in thermal states of different temperatures, this model describes the working principle of an absorption refrigerator that transfers energy from a cold to a hot environment at the expense of free energy provided by a high-temperature work reservoir. Inspired by a recent experimental realization with trapped ions, we elucidate key features of the coupling Hamiltonian that are relevant for the refrigerator performance. The coherent system dynamics exhibits rapid effective equilibration of the mode energies and correlations, as well as a transient enhancement of the cooling performance at short times. We find that these features can be fully reproduced in a classical framework.

  1. Central magnetic cooling and refrigeration machines (chiller) and their assessment. A feasibility study - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Egolf, P. W.; Gonin, C. [University of Applied Sciences of Western Switzerland, HEIG-VD, Yverdon-les Bains (Switzerland); Kitanovski, A. [University of Ljubljana, Ljubljana (Slovenia)

    2010-03-15

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a feasibility study made concerning magnetic cooling and refrigeration machines. This report presents a comprehensive thermodynamic and economic analysis of applications of rotary magnetic chillers. The study deals with magnetic chillers based on permanent magnets and superconducting magnets, respectively. The numerical design of permanent magnet assemblies with different magnetic flux densities is discussed. The authors note that superconducting magnetic chillers are feasible only in large-scale applications with over 1 MW of cooling power. This report describes new ideas for magnetic refrigeration technologies, which go beyond the state of the art. They show potential for a substantial reduction of costs and further improvements in efficiency. Rotary magnetic liquid chillers with 'wavy' structures and using micro tubes are discussed, as are superconducting magnetic chillers and future magneto-caloric technologies.

  2. Computational Evaluation of Mixtures of Hydrofluorocarbons and Deep Eutectic Solvents for Absorption Refrigeration Systems.

    Science.gov (United States)

    Abedin, Rubaiyet; Heidarian, Sharareh; Flake, John C; Hung, Francisco R

    2017-10-24

    We used computational tools to evaluate three working fluid mixtures for single-effect absorption refrigeration systems, where the generator (desorber) is powered by waste or solar heat. The mixtures studied here resulted from combining a widely used hydrofluorocarbon (HFC) refrigerant, R134a, with three common deep eutectic solvents (DESs) formed by mixing choline chloride (hydrogen bond acceptor, HBA) with urea, glycerol, or ethylene glycol as the hydrogen bond donor (HBD) species. The COSMOtherm/TmoleX software package was used in combination with refrigerant data from NIST/REFPROP, to perform a thermodynamic evaluation of absorption refrigeration cycles using the proposed working fluid mixtures. Afterward, classical MD simulations of the three mixtures were performed to gain insight on these systems at the molecular level. Larger cycle efficiencies are obtained when R134a is combined with choline chloride and ethylene glycol, followed by the system where glycerol is the HBD, and finally that where the HBD is urea. MD simulations indicate that the local density profiles of all species exhibit very sharp variations in systems containing glycerol or urea; furthermore, the Henry's law constants of R134a in these two systems are larger than those observed for the HFC in choline chloride and ethylene glycol, indicating that R134a is more soluble in the latter DES. Interaction energies indicate that the R134a-R134a interactions are weaker in the system where ethylene glycol is the HBD, as compared to in the other DES. Radial distribution functions confirm that in all systems, the DES species do not form strong directional interactions (e.g., hydrogen bonds) with the R134a molecules. Relatively strong interactions are observed between the Cl anions and the hydrogen atoms in R134a; however, the atom-atom interactions between R134a and the cation and HBD species are weaker and do not play a significant role in the solvation of the refrigerant. In all systems, R134a has

  3. Solar Absorption Refrigeration System for Air-Conditioning of a Classroom Building in Northern India

    Science.gov (United States)

    Agrawal, Tanmay; Varun; Kumar, Anoop

    2015-10-01

    Air-conditioning is a basic tool to provide human thermal comfort in a building space. The primary aim of the present work is to design an air-conditioning system based on vapour absorption cycle that utilizes a renewable energy source for its operation. The building under consideration is a classroom of dimensions 18.5 m × 13 m × 4.5 m located in Hamirpur district of Himachal Pradesh in India. For this purpose, cooling load of the building was calculated first by using cooling load temperature difference method to estimate cooling capacity of the air-conditioning system. Coefficient of performance of the refrigeration system was computed for various values of strong and weak solution concentration. In this work, a solar collector is also designed to provide required amount of heat energy by the absorption system. This heat energy is taken from solar energy which makes this system eco-friendly and sustainable. A computer program was written in MATLAB to calculate the design parameters. Results were obtained for various values of solution concentrations throughout the year. Cost analysis has also been carried out to compare absorption refrigeration system with conventional vapour compression cycle based air-conditioners.

  4. Simulator for design absorption refrigeration system; Simulador para projeto de ciclos de refrigeracao por absorcao

    Energy Technology Data Exchange (ETDEWEB)

    Morejon, C.F.M.; Brum, N. de C. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Mecanica]. E-mails: Camilo_freddy@hotmail.com; Nisio@serv.com.ufrj.br

    2000-07-01

    This work presents a development of a thermal fluid dynamics model and a solution of a steady state absorption refrigeration cycle, with ammonia water as the working fluid. Analytical thermodynamics models expressing the enthalpy in function of pressure, temperature and composition (h=f(P,T,x)), are used with the aim to design all of the cycle devices, moved by any type of energy such as solar, natural gas, steam or electrical energy (Morejon and Hackenberg, 1978). The development of the analysis is carried out by the application of thermal fluid dynamics concepts together with a detailed study of the heat and mass transfer in the different cycle stages. The thermodynamic cycle model, obtained from equation of state for ammonia - water mixtures (Ziegker and Trepp, 1984), is represented by the relation h - x (enthalpy-composition) for different pressures and temperatures. The obtained models are used to implement computational codes in MAPLE-V facilitating the design and simulation of refrigeration system. This study can be applied in the systems of air conditioning and refrigeration chambers design. (author)

  5. A rich solution spray as a refining method in a small capacity, single effect, solar assisted absorption machine with the pair NH3/H2O: Experimental results

    International Nuclear Information System (INIS)

    Mendes, L.F.; Collares-Pereira, M.; Ziegler, F.

    2007-01-01

    Ammonia vapour refining is a common procedure in ammonia-water absorption machines. A solar assisted single effect absorption machine that uses the pair ammonia-water was developed and tested. Its desorber has a built-in adiabatic refining column constituted by a rich solution spray. The refining method proved its feasibility. The spray provided a more or less constant ammonia vapour enrichment of about 1% which is enough for the working temperature ranges of this type of machine. It was also verified that the refining effect of the spray is almost independent of the refrigerant vapour and solution mass flow rates

  6. Implementation of an object-oriented dynamic modeling library for absorption refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Fu, D.G.; Lu, Z. [Institute of Refrigeration and Cryogenics, School of Mechanical and Power Engineering, Shanghai Jiao Tong University, No. 1954, Hua Shan Road, Shanghai 200030 (China); Poncia, G. [United Technologies Research Center, East Hartford, CT 06108 (United States)

    2006-02-01

    The integration of absorption refrigeration equipment into Cooling, Heating and Power systems must guarantee economic viability, operability and reliability. Accurate control design is mandatory to fulfill such requirements, and make system design successful. The use of model-based control techniques and the introduction of controls testing via numerical simulation rely on the availability of accurate, robust and flexible dynamic models. In this paper, a model library of absorption systems with different working mediums and cycle configurations is presented. Library flexibility and extensibility is achieved through the adoption of object-oriented modeling techniques, allowing considerable reduction of the development time through model reuse. The library has been used to simulate the transient behavior, including startup and shutdown, of several systems. Validation against experimental data has proven the accuracy of modeling assumption. (author)

  7. A LiBr-H2O Absorption Refrigerator Incorporating a Thermally Activated Solution Pumping Mechanism

    Directory of Open Access Journals (Sweden)

    Ian W. Eames

    2017-02-01

    Full Text Available This paper provides an illustrated description of a proposed LiBr-H2O vapour absorption refrigerator which uses a thermally activated solution pumping mechanism that combines controlled variations in generator vapour pressure with changes it produces in static-head pressure difference to circulate the absorbent solution between the generator and absorber vessels. The proposed system is different and potentially more efficient than a bubble pump system previously proposed and avoids the need for an electrically powered circulation pump found in most conventional LiBr absorption refrigerators. The paper goes on to provide a sample set of calculations that show that the coefficient of performance values of the proposed cycle are similar to those found for conventional cycles. The theoretical results compare favourably with some preliminary experimental results, which are also presented for the first time in this paper. The paper ends by proposing an outline design for an innovative steam valve, which is a key component needed to control the solution pumping mechanism.

  8. Mathematical Model of a Lithium-Bromide/Water Absorption Refrigeration System Equipped with an Adiabatic Absorber

    Directory of Open Access Journals (Sweden)

    Salem M. Osta-Omar

    2016-11-01

    Full Text Available The objective of this paper is to develop a mathematical model for thermodynamic analysis of an absorption refrigeration system equipped with an adiabatic absorber using a lithium-bromide/water (LiBr/water pair as the working fluid. The working temperature of the generator, adiabatic absorber, condenser, evaporator, the cooling capacity of the system, and the ratio of the solution mass flow rate at the circulation pump to that at the solution pump are used as input data. The model evaluates the thermodynamic properties of all state points, the heat transfer in each component, the various mass flow rates, and the coefficient of performance (COP of the cycle. The results are used to investigate the effect of key parameters on the overall performance of the system. For instance, increasing the generator temperatures and decreasing the adiabatic absorber temperatures can increase the COP of the cycle. The results of this mathematical model can be used for designing and sizing new LiBr/water absorption refrigeration systems equipped with an adiabatic absorber or for optimizing existing aforementioned systems.

  9. Review on absorption technology with emphasis on small capacity absorption machines

    Directory of Open Access Journals (Sweden)

    Labus Jerko M.

    2013-01-01

    Full Text Available The aim of this paper is to review the past achievements in the field of absorption systems, their potential and possible directions for future development. Various types of absorption systems and research on working fluids are discussed in detail. Among various applications, solar cooling and combined cooling, heating and power (CCHP are identified as two most promising applications for further development of absorption machines. Under the same framework, special attention is given to the small capacity absorption machines and their current status at the market. Although this technology looks promising, it is still in development and many issues are open. With respect to that fact, this paper covers all the relevant aspects for further development of small capacity absorption machines.

  10. Configuration optimization of series flow double-effect water-lithium bromide absorption refrigeration systems by cost minimization

    DEFF Research Database (Denmark)

    Mussati, Sergio F.; Cignitti, Stefano; Mansouri, Seyed Soheil

    2018-01-01

    An optimal process configuration for double-effect water-lithium bromide absorption refrigeration systems with series flow – where the solution is first passed through the high-temperature generator – is obtained by minimization of the total annual cost for a required cooling capacity. To this end......W) and the temperature of the cooling water (15–35 °C). The results of this work motivate to apply the simultaneous optimization approach to seek for new multi-effect absorption refrigeration system configurations with parallel and reverse flow as well as other series flow arrangements that minimize the total annual...

  11. Experimental results of a direct air-cooled ammonia–lithium nitrate absorption refrigeration system

    International Nuclear Information System (INIS)

    Llamas-Guillén, S.U.; Cuevas, R.; Best, R.; Gómez, V.H.

    2014-01-01

    Absorption thermal cooling systems driven by renewable energy are a viable option in order to reduce fossil fuel consumption and the associated emissions. This work shows the results of an air cooled absorption cooling prototype working with an ammonia–lithium nitrate mixture at high ambient temperatures. An absorption refrigeration system was designed and built. The prototype is a one stage ammonia–lithium nitrate air cooled chiller. The experimental system was instrumented to evaluate each component. This paper shows the operation conditions in the experimental unit as well as some of the heat loads encountered at different operating conditions. The system was operated successfully at ambient temperatures in the range of 25–35 °C. A series of test showed that even at ambient temperatures it can be operated at evaporator temperatures below 10 °C producing chilled water for air conditioning applications such as radiative cooling panels. The system proved to stabilize very quickly and no risk of crystallization was encountered so the first results are promising in order to continue with the development of a more advanced prototype. - Highlights: •Experimental results of a direct air-cooled ammonia–lithium nitrate system. •The prototype is a one stage ammonia–lithium nitrate air cooled chiller. •The absorption system was operated successfully at ambient temperatures. •Cooling loads of 4.5 kW were reached in the chilled water side

  12. Synthesis of integrated absorption refrigeration systems involving economic and environmental objectives and quantifying social benefits

    International Nuclear Information System (INIS)

    Lira-Barragán, Luis Fernando; Ponce-Ortega, José María; Serna-González, Medardo; El-Halwagi, Mahmoud M.

    2013-01-01

    This paper presents a new methodology for energy integration of systems that require absorption refrigeration. It allows heat exchange among process hot and cold streams and the integration of excess process heat as well as external utilities provided by solar energy, fossil fuels and biofuels. An optimization formulation is developed to address the multiple objectives of simultaneously minimizing the total annualized cost and the greenhouse gas emissions while the social impact is measured by the number of jobs generated by the project in the entire life cycle. The economic function accounts for the tax credit obtained by the reduction of greenhouse gas emissions when cleaner technologies are used. The proposed model also considers the optimal selection of different types of solar collectors and the optimal time-based usage of solar energy, fossil fuel, and biofuel. Two example problems are presented to show the applicability of the proposed methodology. -- Highlights: ► An approach for the thermal integration of refrigeration processes is proposed. ► Different forms of sustainable energies are considered in the optimization process. ► Economic and environmental objectives are considered quantifying the number of jobs. ► The availability for the different forms of energy is taken into account. ► Results show significant advantages obtained with the proposed approach

  13. Raw milk from vending machines: Effects of boiling, microwave treatment, and refrigeration on microbiological quality.

    Science.gov (United States)

    Tremonte, Patrizio; Tipaldi, Luca; Succi, Mariantonietta; Pannella, Gianfranco; Falasca, Luisa; Capilongo, Valeria; Coppola, Raffaele; Sorrentino, Elena

    2014-01-01

    In Italy, the sale of raw milk from vending machines has been allowed since 2004. Boiling treatment before its use is mandatory for the consumer, because the raw milk could be an important source of foodborne pathogens. This study fits into this context with the aim to evaluate the microbiological quality of 30 raw milk samples periodically collected (March 2013 to July 2013) from 3 vending machines located in Molise, a region of southern Italy. Milk samples were stored for 72 h at 4 °C and then subjected to different treatments, such as boiling and microwaving, to simulate domestic handling. The results show that all the raw milk samples examined immediately after their collection were affected by high microbial loads, with values very close to or even greater than those acceptable by Italian law. The microbial populations increased during refrigeration, reaching after 72 h values of about 8.0 log cfu/mL for Pseudomonas spp., 6.5 log cfu/mL for yeasts, and up to 4.0 log cfu/mL for Enterobacteriaceae. Boiling treatment, applied after 72 h to refrigerated milk samples, caused complete decontamination, but negatively affected the nutritional quality of the milk, as demonstrated by a drastic reduction of whey proteins. The microwave treatment at 900 W for 75 s produced microbiological decontamination similar to that of boiling, preserving the content in whey proteins of milk. The microbiological characteristics of raw milk observed in this study fully justify the obligation to boil the raw milk from vending machines before consumption. However, this study also showed that domestic boiling causes a drastic reduction in the nutritional value of milk. Microwave treatment could represent a good alternative to boiling, on the condition that the process variables are standardized for safe domestic application. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. The performance analysis of a novel absorption refrigeration cycle used for waste heat with large temperature glide

    International Nuclear Information System (INIS)

    Shi, Yuqi; Chen, Guangming; Hong, Daliang

    2016-01-01

    Highlights: • A new absorption chiller utilizing heat with a large temperature glide is proposed. • Thermodynamic calculations are conducted to analyze the system performance. • Steady-state parametric studies are conducted for this system. • ω of the new cycle is much higher than that of a single effect cycle. • The new cycle can obtain lower temperature and use lower grade heat. - Abstract: To make full utilization of waste heat with large temperature glide, a new absorption refrigeration cycle with a simple construction is proposed. In this cycle, the solution flowing out from a low-pressure and high-temperature absorber absorbs refrigerant vapor in a low-pressure and low-temperature absorber which is cooled by evaporating refrigerant in a high-pressure evaporator. The refrigerant vapor to be absorbed in the low-pressure and low-temperature absorber comes from a low-pressure evaporator. The vapor flowing out from the high-pressure evaporator is absorbed by solution in a high-pressure absorber. This solution sent to a liquid pump comes from a low-pressure and low-temperature absorber. Compared to a single-effect absorption cycle, the molar fraction of refrigerant of the solution into generator is much greater, resulting in drastic temperature decline for the displaced exhaust gas/water of this cycle, which means the new cycle can effectively utilize waste heat with large temperature glide. Theoretical simulation results show that the cooling capacity per unit mass of exhaust gas of the proposed cycle is about 20% higher than that of a single-effect absorption cycle, especially for the situation that temperature of supplied waste heat is lower and/or refrigeration temperature is lower.

  15. A solar absorption refrigeration system operating with the mixture ammonia-lithium nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, W.; Martinez, F.; Garcia-Valladares, O. [Centro de Investigacion en Energia de la Univ. Nacional Autonoma de Mexico, Mor (Mexico); Rivera, C.O. [Univ. Veracruzana, Campus Coatzacoalcos (Mexico)

    2007-07-01

    An intermittent solar absorption refrigeration system for ice production operating with the ammonia-lithium nitrate mixture has been developed in the Centro de Investigacion en Energia of the Universidad Nacional Autonoma de Mexico. The system consists basically of a compound parabolic concentrator (CPC), a generator-absorber, a condenser, a condensate tank, an expansion valve and an evaporator. The system was evaluated in sunny days with insolations above 20 MJ/m{sup 2}-day at different condenser temperatures. The generator temperatures varied from 108 to 121 C and the evaporator temperatures inside the camera from -8 to 0 C. The coefficients of performance (COP) varied from 0.13 to 0.26 depending of the operating temperatures of the system and the solar irradiation. (orig.)

  16. The influence of diffusion absorption refrigeration cycle configuration on the performance

    International Nuclear Information System (INIS)

    Zohar, A.; Jelinek, M.; Levy, A.; Borde, I.

    2007-01-01

    Based on a full thermodynamic model for ammonia-water diffusion absorption refrigeration (DAR) cycle with hydrogen as the auxiliary inert gas, the performance of two fundamental configurations of a DAR cycle, with and without condensate sub-cooling prior to the evaporator entrance, were studied and compared. The performances of the two cycles were examined parametrically by computer simulations. Mass and energy conservation equations were developed for each component of the cycles and solved numerically. It was found that the DAR cycle without condensate sub-cooling shows higher COP of 14-20% in compare with the DAR cycle with the condensate sub-cooling, but it occurs at higher evaporator temperature of about 15 deg. C

  17. Thermodynamic analysis of diesel engine coupled with ORC and absorption refrigeration cycle

    International Nuclear Information System (INIS)

    Salek, Farhad; Moghaddam, Alireza Naghavi; Naserian, Mohammad Mahdi

    2017-01-01

    Highlights: • Coupling ORC and Ammonia absorption cycles with diesel engine to recover energy. • By using designed bottoming system, recovered diesel engine energy is about 10%. • By using designed bottoming system, engine efficiency will grow about 4.65%. - Abstract: In this paper, Rankine cycle and Ammonia absorption cycle are coupled with Diesel engine to recover the energy of exhaust gases. The novelty of this paper is the use of ammonia absorption refrigeration cycle bottoming Rankine cycle which coupled with diesel engine to produce more power. Bottoming system converts engine exhaust thermal energy to cooling and mechanical energy. Energy transfer process has been done by two shell and tube heat exchangers. Simulation processes have been done by programming mathematic models of cycles in EES Program. Based on results, recovered energy varies with diesel engine load. For the particular load case of current research, the use of two heat exchangers causes 0.5% decrement of engine mechanical power. However, the recovered energy is about 10% of engine mechanical power.

  18. Numerical Study of Compact Plate-Fin Heat Exchanger for Rotary-Vane Gas Refrigeration Machine

    Directory of Open Access Journals (Sweden)

    V. V. Trandafilov

    2017-10-01

    Full Text Available Plate-fin heat exchangers are widely used in refrigeration technique. They are popular because of their compactness and excellent heat transfer performance. Here we present a numerical model for the development, research and optimization of a plate-fin heat exchanger for a rotary-vane gas refrigeration machine. The method of analysis by graphic method of plate - fin heat exchanger is proposed. The model describes the effects of secondary parameters such as axial thermal conductivity through a metal matrix of the heat exchanger. The influence of geometric parameters and heat transfer coefficient is studied. Graphs of dependences of length, efficiency of a fin and pressure drop in a heat exchanger on the thickness of the fin and the number of fins per meter are obtained. To analyze the results of numerical simulation, the heat exchanger was designed in the Aspen HYSYS program. The simulation results show that the total deviation from the proposed numerical model is not more than 15%. 

  19. Industrial refrigeration with high efficiency absorption; Refrigeracion industrial por absorcion de alta eficiencia

    Energy Technology Data Exchange (ETDEWEB)

    Ayala Delgado, R.; Heard, C. L. [Instituto de Investigaciones Electricas, Cuernavaca, (Mexico); Pardubicki, J. [LAJ International, Mexico D. F. (Mexico)

    1995-12-31

    The absorption refrigeration ammonia-lithium nitrate offers great advantages compared with the mechanical compression refrigeration with ammonia as well as with the absorption ammonia-water refrigeration. With heat temperatures of 1000 to 1400 Celsius degrees, for instance low pressure steam the generation of cold at low temperatures (-100 to -200 Celsius degrees) is possible. The system has less components and is much less expensive than the ammonia-water equipment with a price very similar to the ammonia mechanical compression equipment. The equipment consists of five main heat exchangers and a solution pump, resulting in a high reliability of its operation, requiring a minimum maintenance. The operation cost depends directly of the cost of the energy source. In case of using residual heat the operation cost is only the maintenance cost. Nowadays the cost of the electric energy is below the production cost, which can be a short term situation. In time terms of the comparable useful life time of an absorption refrigeration system (in excess of 20 years), it is reasonable to think that the operation costs will be less than the operation costs of an equipment with mechanical compression. To this day it is available a demonstration unit to exhibit the system in industrial plants with different energy sources. [Espanol] La refrigeracion por absorcion amoniaco/nitrato de litio ofrece grandes ventajas comparada tanto con la refrigeracion por compresion mecanica con amoniaco como con la refrigeracion por absorcion amoniaco/agua. Este sistema es mas eficiente y sencillo que el sistema de amoniaco/agua. Con calor de temperatura (100 a 140 grados centigrados por ejemplo vapor de baja presion, se permite la generacion de frio a temperaturas bajas (-10 a -20 grados centigrados). El sistema tiene menos componentes y es mucho mas barato que equipo de amoniaco/agua con un precio muy similar a sistemas por compresion mecanica de amoniaco. El sistema consiste en cinco

  20. A thermodynamic evaluation on high pressure condenser of double effect absorption refrigeration system

    International Nuclear Information System (INIS)

    Yılmaz, İbrahim Halil; Saka, Kenan; Kaynakli, Omer

    2016-01-01

    One of the parameters affecting the COP of the absorption system can be considered as the thermal balance between the high pressure condenser (HPC) and the low pressure generator (LPG) since heat rejected from the HPC is utilized as an energy source by the LPG. Condensation of the water vapor in the HPC depends on the heat removal via the LPG. This circumstance is significant for making an appropriate design and a controllable system with high performance in practical applications. For this reason, a thermodynamic analysis for the HPC of a double effect series flow water/lithium bromide absorption refrigeration system was emphasized in this study. A simulation was developed to investigate the energy transfer between the HPC and LPG. The results show that the proper designation of the HPC temperature improves the COP and ECOP due its significant impact, and its value necessarily has to be higher than the outlet temperature of the LPG based on the operating scheme. Furthermore, the COP and ECOP of the absorption system can be raised in the range of 9.72–35.09% in case of 2 °C-temperature increment in the HPC under the described conditions to be applied. - Highlights: • Thermal balance in HPC/LPG unit of a double effect absorption system was studied. • A simulation program was developed and its outputs were validated. • A parametric study was conducted for a wide range of component temperatures. • Proper designation of the HPC temperature improves the COP and ECOP. • The system performance raised 9.72–35.09% by controlling the HPC temperature.

  1. Experimental investigation on an ammonia-water-lithium bromide absorption refrigeration system without solution pump

    International Nuclear Information System (INIS)

    Wu Tiehui; Wu Yuyuan; Yu Zhiqiang; Zhao Haichen; Wu Honglin

    2011-01-01

    Highlights: → An absorption refrigeration system with ternary solution of NH 3 -H 2 O-LiBr was set up. → Performance of the NH 3 -H 2 O-LiBr system without solution pump was firstly tested. → Generator pressure in NH 3 -H 2 O-LiBr system was lower than the one in NH 3 -H 2 O system. → The COP of the NH 3 -H 2 O-LiBr system was 51.89% larger than the NH 3 -H 2 O binary system. → The optimum mass fraction of LiBr of about 23% led to the largest COP of 0.401. -- Abstract: Experimental researches were carried out on a novel ammonia-water-lithium bromide ternary solution absorption refrigeration and air-conditioning system without solution pump and distillation equipments. The experiments were conducted by using three kinds of NH 3 -H 2 O binary solution and 17 kinds of ternary solution with difference in mass fraction of NH 3 and LiBr. The experimental results showed that the vapor pressure of the generator in the system would be lower than that of the generator in an ammonia-water absorption system. In above two situations the same ammonia mass fraction and the same solution temperature were kept. The amplitude of vapor pressure decrease of the system generator would be larger with the increase of the mass fraction of LiBr. The maximum amplitude of decrease would be of 50%. With the increase of the mass fraction of LiBr, the coefficient of performance (COP) of the system would be increased initially, and then decreased later when the mass fraction of LiBr exceeded a certain value. This value was about 23% for the solution with ammonia mass fraction of 50% and 55%, and about 30% for the solution with ammonia mass fraction of 60%. Compared with the ammonia-water system, the COP of the ternary solution system with the same mass fraction of ammonia would increase up to 30%. With the ammonia mass fraction of 60% and LiBr mass fraction of 30% applied, the COP of the ternary solution system was increased up to 0.401. It was 51.89% higher than that when binary

  2. Standard GAX versus hybrid GAX absorption refrigeration cycle: From the view point of thermoeconomics

    International Nuclear Information System (INIS)

    Mehr, A.S.; Zare, V.; Mahmoudi, S.M.S.

    2013-01-01

    Highlights: • The SGAX cycle is found to be thermoeconomically efficient compared to HGAX cycle. • The HGAX cycle has higher COP and exergy efficiency compared to SGAX cycle. • Minimum product cost is found 180.5 $/GJ and 159.1 $/GJ for HGAX and SGAX, respectively. - Abstract: The main goal of this research is to compare thermoeconomic performance of a GAX absorption cycle and a hybrid GAX absorption cycle in which a compressor is employed to raise the absorber pressure. In order to do this, the ammonia–water standard GAX (SGAX) and hybrid GAX (HGAX) absorption refrigeration cycles are investigated and optimized from the viewpoints of thermodynamics and economics. Parametric studies are carried out and with the help of genetic algorithm (GA), the cycles’ performance is optimized based on the COP and exergy efficiency as well as the cost of unit product. Results indicate that although, compared to the GAX cycle, the HGAX cycle demonstrates a better performance from the view points of both the first and second laws of thermodynamics, the unit product cost for the HGAX cycle is higher. At the optimum operating conditions, the cost of unit product for the HGAX cycle is calculated as 180.5 $/GJ while the corresponding value for the SGAX cycle is obtained as 159.1 $/GJ. Also, the exergoeconomic analyses unfold that the condenser has the lowest exergoeconomic factor, f, in both the systems. In addition, inspired from nature, a new graphical plot is proposed to illustrate the fuel cost, product cost, capital investment and operating and maintenance cost and cost rates associated with the exergy destruction and losses within the system’s components

  3. Recent evolutions of refrigerating machineries and heat pumps; Evolutions recentes des machines a froid et thermopompes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    This book of proceedings reports on 10 papers (or series of transparencies) concerning some recent developments about refrigerating machineries and heat pumps as used in space heating, air-conditioning and industrial refrigeration. Various aspects are developed: thermodynamic cycles, thermal performances, dimensioning, modeling, refrigerants substitution, design of flanged exchangers, compressors etc.. (J.S.)

  4. Absorption refrigeration cycle applied to offshore platforms; Refrigeracao por absorcao aplicada a plataformas de petroleo

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Maximino Joaquim Pina [KROMAV Engenharia, Rio de Janeiro, RJ (Brazil); Pinto, Luiz Antonio Vaz; Belchior, Carlos Rodrigues Pereira [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE)

    2004-07-01

    To produce cold from the heat seems a task unlikely or even impossible. However, absorption systems produce cooling from heat sources and it exist since the century XIX. In industrial places is very important to improve the energy use, even more in places where the activities involve great costs and incomes. Traditionally the alternatives conflict in the aspects of initial and operational costs. This paper describes the absorption systems operation and its main advantages and disadvantages, when compared to the traditional systems with compressor. The known fact that a vapor compressor system presents larger efficiency is not enough to validate it for all of the applications. In this sense, the initial and operational analysis of the costs of the absorption systems becomes interesting. In spite of, double effect absorption systems are demonstrating the evolution of the absorption cycle in order to obtain better performance. Turbo-generators and Turbo-compressors of the offshore platforms are thermal machines that reject great amount of heat in the exhaust gases. This heat is used for heating of water used in the Process Plant. The processes of separation of the mixture water-oil-gas from the well, for instance, use that heat. Even after the passage of the water in the Plant of Process, the residual heat is still enough for the use in absorption systems. A simulation is done using real data of an offshore platform. Two possible alternatives are compared under technical and economical aspects. Sensibility analysis is also performed in order to verify possible impacts of variations of electric power cost. (author)

  5. Absorption cycle commercial refrigerator using wood burning cook stove; Geladeira de absorcao acionada por fogao a lenha

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Jose Tomaz Vieira; Martins, Gilberto [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Energia

    1990-12-31

    The current utilization of wood burning cook stoves in Brazil and the socio-economical profile of their users were surveyed. A traditional heavy-mass wood-burning cook stove was studied as a thermal equipment. Simple changes in the geometry of the combustion chamber were suggested to improve the cooking efficiency. A closed two-phase thermosyphon using water as working fluid was designed, built and connected between the combustion chamber of the cook stove and a depressurized absorption refrigeration system to determine the heat flux and the temperature level. A commercial refrigerator unit, using the absorption cycle, was coupled with the wood stove through the thermosyphon. The overall results of the coupling point to successful country-side applications. (author) 12 refs., 9 figs., 4 tabs.

  6. Energetic analysis of a commercial absorption refrigeration unit using an ammonia-water mixture

    Directory of Open Access Journals (Sweden)

    Josegil Jorge de Araújo

    2017-09-01

    Full Text Available The ROBUR® absorption refrigeration system (ARS, model ACF60, with a capacity of 17.5 kW, is tested, modeled and simulated in the steady state. To simulate the thermal load a heating system with secondary coolant was used, in which a programmable logic controller (PLC kept the inlet temperature EVA at around 285.15 K. The mathematical model used was based on balancing the mass, energy and ammonia concentrations and completed by closing equations such as, Newton's cooling equation. The mathematical model was implemented using the Engineering Equation Solver – EES®. The results obtained after modeling and a numerical permanent simulation are studied using the Duhring diagram. Potential points of internal heat recovery are visualized, and by using graphs of the binary mixture, it is possible to identify the thermodynamic states of all monitored points. The data obtained in the numerical simulation of the ARS was compared with data acquired in the actual tests of the ARS with the ROBUR® apparatus.

  7. Exergy analysis of single effect absorption refrigeration systems: The heat exchange aspect

    International Nuclear Information System (INIS)

    Joybari, Mahmood Mastani; Haghighat, Fariborz

    2016-01-01

    Highlights: • Exergy analysis of LiBr/H 2 O absorption systems with identical COP was carried out. • Exergy destruction rank: absorber followed by generator, condenser and evaporator. • Lower heat source and chilled water inlet temperature reduced exergy destruction. • Higher cooling water inlet temperature reduced exergy destruction. • Lower HTF mass flow rate increased exergy efficiency even for fixed system COP. - Abstract: The main limitation of conventional energy analysis for the thermal performance of energy systems is that this approach does not consider the quality of energy. On the other hand, exergy analysis not only provides information about the systems performance, but also it can specify the locations and magnitudes of losses. A number of studies investigated the effect of parameters such as the component temperature, and heat transfer fluid (HTF) temperature and mass flow rate on the exergetic performance of the same absorption refrigeration system; thus, reported different coefficient of performance (COP) values. However, in this study, the system COP was considered to remain constant during the investigation. This means comparing systems with different heat exchanger designs (based on HTF mass flow rate and temperature) having the same COP value. The effect of HTF mass flow rate and inlet temperature of the cooling water, chilled water and heat source on the outlet specific exergy and exergy destruction rate of each component was investigated. It was found that the lower HTF mass flow rate decreased exergy destruction of the corresponding component. Moreover, the lower temperature of heat source and chilled water inlet increased the system exergetic efficiency. That was also the case for the higher cooling water inlet temperature. Based on the analysis, since the absorber and condenser accounted for a large portion of the total exergy destruction, cooling tower modification with lower cooling water mass flow rate is recommended

  8. Thermoacoustic refrigeration

    Science.gov (United States)

    Garrett, Steven L.; Hofler, Thomas J.

    1991-12-01

    A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

  9. Some comments about the comparison between a conventional and a solar powered absorption refrigeration system

    International Nuclear Information System (INIS)

    Corbella, O.D.; Garibotti, C.R.

    1983-08-01

    Two statements about the performance of solar refrigeration systems are discussed. First, concepts of efficiency and coefficient of performance are studied. Second, the influence of inflation and rise of fuel prices are considered, in relation to the comparison between solar and conventional refrigeration systems. (author)

  10. A method for obtaining performance correlations of absorption machines

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Pedro Juan [E.T.S. Ingenieros Industriales, Universidad Politecnica de Cartagena, Campus Muralla del Mar, 30202, Cartagena (Spain); Pinazo, Jose Manuel [E.T.S. Ingenieros Industriales, Universidad Politecnica de Valencia, Cmno. de Vera s/n, 46022, Valencia (Spain)

    2003-04-01

    Several authors have developed models to be implemented in building thermal simulation programs for modelling absorption machines. Some anarchy has been detected related to the order of these models and the variables they consist of. In this paper, specific statistical tools were employed to establish regression models for the COP and the capacity of a water-lithium bromide single-effect absorption chiller. Experimental designs were used to obtain the data (values of COP and capacity) utilized to estimate the model parameters. The hypotheses initially adopted in the formulation of the models were modified at the sight of the results of subjecting the values obtained for the response variables to a variance analysis. (authors)

  11. Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature

    Directory of Open Access Journals (Sweden)

    Osman Wageiallah Mohammed

    2017-10-01

    Full Text Available Solar-driven ammonia-water absorption refrigeration system (AARS has been considered as an alternative for the conventional refrigeration and air-conditioning systems. However, its high initial cost seems to be the main problem that postpones its wide spread use. In the present study, a single-stage NH3/H2O ARS is analyzed in depth on the basis of energetic and exergetic coefficients of performance (COP and ECOP, respectively to decrease its cut in/off temperature. This study was carried out to lower the required heat source temperature, so that a less-expensive solar collector could be used. Effects of all parameters that could influence the system’s performance and cut in/off temperature were investigated in detail. Presence of water in the refrigerant and evaporator temperature glide was considered. Results revealed that appropriate selection of system’s working condition can effectively reduce the driving temperature. Besides, the cut in/off temperature can be significantly decreased by inserting an effective solution heat exchanger (SHX. Required driving temperature can be lowered by up to 10 °C using SHX with 0.80 effectiveness. The results also showed that effects of water content in the refrigerant could not be neglected in studying NH3/H2O ARS because it affects both COP and ECOP. Additionally, a large temperature glide in the evaporator can substantially decrease the ECOP.

  12. Solar hybrid cooling system for high-tech offices in subtropical climate - Radiant cooling by absorption refrigeration and desiccant dehumidification

    International Nuclear Information System (INIS)

    Fong, K.F.; Chow, T.T.; Lee, C.K.; Lin, Z.; Chan, L.S.

    2011-01-01

    Highlights: → A solar hybrid cooling system is proposed for high-tech offices in subtropical climate. → An integration of radiant cooling, absorption refrigeration and desiccant dehumidification. → Year-round cooling and energy performances were evaluated through dynamic simulation. → Its annual primary energy consumption was lower than conventional system up to 36.5%. → The passive chilled beams were more energy-efficient than the active chilled beams. - Abstract: A solar hybrid cooling design is proposed for high cooling load demand in hot and humid climate. For the typical building cooling load, the system can handle the zone cooling load (mainly sensible) by radiant cooling with the chilled water from absorption refrigeration, while the ventilation load (largely latent) by desiccant dehumidification. This hybrid system utilizes solar energy for driving the absorption chiller and regenerating the desiccant wheel. Since a high chilled water temperature generated from the absorption chiller is not effective to handle the required latent load, desiccant dehumidification is therefore involved. It is an integration of radiant cooling, absorption refrigeration and desiccant dehumidification, which are powered up by solar energy. In this study, the application potential of the solar hybrid cooling system was evaluated for the high-tech offices in the subtropical climate through dynamic simulation. The high-tech offices are featured with relatively high internal sensible heat gains due to the intensive office electric equipment. The key performance indicators included the solar fraction and the primary energy consumption. Comparative study was also carried out for the solar hybrid cooling system using two common types of chilled ceilings, the passive chilled beams and active chilled beams. It was found that the solar hybrid cooling system was technically feasible for the applications of relatively higher cooling load demand. The annual primary energy

  13. Numerical Investigation of an Absorption-Diffusion Cooling Machine Using C3H8/C9H20 as Binary Working Fluid Étude numérique d’une machine frigorifique à absorption-diffusion utilisant le couple C3H8/C9H20

    Directory of Open Access Journals (Sweden)

    Dardour H.

    2013-05-01

    Full Text Available This paper is concerned with the analysis and the simulation of a heat-driven absorption-diffusion cooling machine which can operate with low-grade heat sources. The simplified configuration of the heat-powered absorption-diffusion refrigerating machine considered in this study is based on the Platen-Munters single pressure refrigerators principle [Platen B.C.V. and Munters C.G. (1928 Refrigerator, US Patent 1, 685-764J. Three working fluids are used, nonane as an absorbent, propane as a refrigerant and hydrogen as the inert auxiliary gas. The designed cooling capacity of the machine is 1 kW which is suitable for a domestic use for refrigeration purposes. We restricted the maximum temperature of the driving heat supplied to the generator to 130 °C, a temperature achievable with evacuated-tube solar collectors. The simulations are carried out using a commercially available flow sheeting software with the PengRobinson equation of state as property prediction method. In this paper, we analyze the heat and mass transfer characteristics in all relevant machine components (absorber, condenser, generator and solution heat exchangers. The simulations results allow determining the values of different parameters of the systems such as the refrigerant and the solvent temperatures in various points of the machine, the liquid and the vapor flow rates and compositions. The system performances were parametrically analyzed using the flow sheeting software. Performance characteristics were determined for a wide range of operating conditions allowing investigating and evaluating the effect of various design parameters. Ce papier est consacré à l’étude et l’analyse d’une machine frigorifique à absorption-diffusion. La machine est actionnée grâce à une source de chaleur de température modérée. La configuration et le principe de fonctionnement de l’appareil obéissent au modèle de Platen Munters [Platen B.C.V. and Munters C.G. (1928 Refrigerator

  14. Cost Price of Products in the System of Heat, Refrigeration and Electric Energy Production Combined at Thermal Power Plant

    OpenAIRE

    Tubolev, Aleksandr Anatolievich; Romashova, Olga Yurievich; Belyaev, Leonid Aleksandrovich

    2016-01-01

    Nowadays combination of electric, heat and refrigerating energy production (trigeneration) is one of the modern technological solutions for energy efficiency increase and ecological problem solution [1]. Two types of refrigerating machines can be used for both energy and heat production combined: compression aggregates consuming electric energy and absorption aggregates using hot water heat, vapor or other heat conductors.

  15. Sustainable cold generation by district heat driven absorption refrigerating machinery. High chilling of return flow; Nachhaltige Kaelteerzeugung durch Fernwaermeangetriebene Absorptionskaeltemaschine. Hohe Auskuehlung des Ruecklaufs

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2011-06-15

    Cold generation with district heat is still an exception in Germany. The trend towards combined heat and power generation and the increasing demand for reserve power within minutes and at acceptable cost, the economic efficieny of thermal refrigeration processes will be easier to define in the future. The author presents an exemplary building in the German city of Giessen, where a cafe on the 13th level as well as a doctor's surgery are cooled in summer by an absorption refrigerator cooled by district heat.

  16. Use of process steam in vapor absorption refrigeration system for cooling and heating applications: An exergy analysis

    Directory of Open Access Journals (Sweden)

    S. Anand

    2016-12-01

    Full Text Available The exponential increase in cost of conventional fuels shifts the interest toward the use of alternative as well waste energy sources for the operation of refrigeration and air-conditioning units. The present study therefore analyzes the performance of a process steam-operated vapor absorption system for cooling and heating applications using ammonia and water as working fluids based on first and second laws of thermodynamics. A mathematical model has been developed based on exergy analysis to investigate the performance of the system. The different performance parameters such as coefficient of performance (COP and exergetic efficiency of absorption system for cooling and heating applications are also calculated under different operating conditions. The results obtained show that cooling and heating COP along with second law efficiency (exergy efficiency increases with the heat source temperature at constant evaporator, condenser, and absorber temperature. Also, COP as well as exergy efficiency increases with an increase in the evaporator temperature at constant generator, condenser, and absorber temperature. The effect of ambient temperature on the exergetic efficiency for cooling and heating applications is also studied. The results obtained from the simulation studies can be used to optimize different components of the system so that the performance can be improved significantly.

  17. Absorption of language concepts in the machine mind

    Science.gov (United States)

    Kollár, Ján

    2016-06-01

    In our approach, the machine mind is the applicative dynamic system represented by its algorithmically evolvable internal language. By other words, the mind and the language of mind are synonyms. Coming out from Shaumyan's semiotic theory of languages, we present the representation of language concepts in the machine mind as a result of our experiment, to show non-redundancy of the language of mind. To provide useful restriction for further research, we also introduce the hypothesis of semantic saturation in Computer-Computer communication, which indicates that a set of machines is not self-evolvable. The goal of our research is to increase the abstraction of Human-Computer and Computer-Computer communication. If we want humans and machines comunicate as a parent with the child, using different symbols and media, we must find the language of mind commonly usable by both machines and humans. In our opinion, there exist a kind of calm language of thinking, which we try to propose for machines in this paper. We separate the layers of a machine mind, we present the structure of the evolved mind and we discuss the selected properties. We are concentrating on the representation of symbolized concepts in the mind, that are languages, not just grammars, since they have meaning.

  18. Stirling Refrigerator

    Science.gov (United States)

    Kagawa, Noboru

    A Stirling cooler (refrigerator) was proposed in 1862 and the first Stirling cooler was put on market in 1955. Since then, many Stirling coolers have been developed and marketed as cryocoolers. Recently, Stirling cycle machines for heating and cooling at near-ambient temperatures between 173 and 400K, are recognized as promising candidates for alternative system which are more compatible with people and the Earth. The ideal cycles of Stirling cycle machine offer the highest thermal efficiencies and the working fluids do not cause serious environmental problems of ozone depletion and global warming. In this review, the basic thermodynamics of Stirling cycle are briefly described to quantify the attractive cycle performance. The fundamentals to realize actual Stirling coolers and heat pumps are introduced in detail. The current status of the Stirling cycle machine technologies is reviewed. Some machines have almost achieved the target performance. Also, duplex-Stirling-cycle and Vuilleumier-cycle machines and their performance are introduced.

  19. OPTIMIZATION OF ABSORPTION SYSTEMS: CASE OF THE REFRIGERATORS AND HEAT PUMPS

    OpenAIRE

    Tchinda , René; Wouagfack , Ngouateu ,

    2017-01-01

    International audience; The new thermo-ecological performance optimization of absorption is investigated by taking the ecological coefficient of performance ECOP as an objective function. ECOP has been expressed in terms of the temperatures of the working fluid in the main components of the system. The maximum of ECOP and the corresponding optimal temperatures of the working fluid and other optimal performance design parameters such as coefficient of performance, specific cooling load of abso...

  20. Feasibility and Basic Design of Solar Integrated Absorption Refrigeration for an Industry

    KAUST Repository

    Akhtar, Saad

    2015-08-28

    This paper presents a review of existing solar cooling technologies and a feasibility study of a solar absorption cooling system for a packaging facility at Tetrapak Lahore, Pakistan. The review includes brief description of existing chiller technologies and solar collectors. The case study includes analysis of the solar potential and design of the cooling system at considered site. The design calculations upon which the feasibility analysis is carried out are solar collector area and type, cooling capacity, cooling area. A comparison is made between solar cooling potential of Pakistan and existing sites all across the globe. Finally an economic analysis is carried out to demonstrate the financial viability of the new cooling system.

  1. Simulation of an air conditioning absorption refrigeration system in a co-generation process combining a proton exchange membrane fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Pilatowsky, I.; Gamboa, S.A.; Rivera, W. [Centro de Investigacion en Energia - UNAM, Temixco, Morelos (Mexico); Romero, R.J. [Centro de Investigacion en Ingenieria y Ciencias Aplicadas - UAEM, Cuernavaca, Morelos (Mexico); Isaza, C.A. [Universidad Pontificia Bolivariana, Medellin (Colombia). Instituto de Energia y Termodinamica; Sebastian, P.J. [Centro de Investigacion en Energia - UNAM, Temixco, Morelos (Mexico); Cuerpo Academico de Energia y Sustentabilidad-UP Chiapas, Tuxtla Gutierrez, Chiapas (Mexico); Moreira, J. [Cuerpo Academico de Energia y Sustentabilidad-UP Chiapas, Tuxtla Gutierrez, Chiapas (Mexico)

    2007-10-15

    In this work, a computer simulation program was developed to determine the optimum operating conditions of an air conditioning system during the co-generation process. A 1 kW PEMFC was considered in this study with a chemical/electrical theoretical efficiency of 40% and a thermal efficiency of 30% applying an electrical load of 100%. A refrigeration-absorption cycle (RAC) operating with monomethylamine-water solutions (MMA-WS), with low vapor generation temperatures (up to 80 C) is proposed in this work. The computer simulation was based on the refrigeration production capacity at the maximum power capacity of the PEMFC. Heat losses between the fuel cell and the absorption air conditioning system at standard operating conditions were considered to be negligible. The results showed the feasibility of using PEMFC for cooling, increasing the total efficiency of the fuel cell system. (author)

  2. Atomic structure of machined semiconducting chips: An x-ray absorption spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Paesler, M.; Sayers, D.

    1988-12-01

    X-ray absorption spectroscopy (XAS) has been used to examine the atomic structure of chips of germanium that were produced by single point diamond machining. It is demonstrated that although the local (nearest neighbor) atomic structure is experimentally quite similar to that of single crystal specimens information from more distant atoms indicates the presence of considerable stress. An outline of the technique is given and the strength of XAS in studying the machining process is demonstrated.

  3. Sistema de refrigeración solar por absorción para la comunidad de Kumay en Ecuador; Solar absorption refrigeration system for Kumay community in Ecuador

    Directory of Open Access Journals (Sweden)

    José Antonio Romero Paguay

    2015-04-01

    Full Text Available En el Ecuador existen muchas zonas aisladas, no electrificadas aún, especialmente en la provincia de Pastaza, en este artículo se presenta un sistema de refrigeración por absorción solar  como una alternativa para la climatización de un consultorio médico en la Comunidad de Kumay. Se realiza el cálculo de la estimación de carga térmica en el consultorio médico empleando el software Carrier E20, el cual arroja una necesidad de enfriamiento de 10 kW o 2,84 toneladas de refrigeración (TR. El sistema de refrigeración por absorción con energía solar propuesto está formado por una máquina de absorción, simple efecto de la marca ClimateWell 10, con 10 kW de potencia de enfriamiento que utiliza como absorbente el par cloruro de litio y agua, requiriéndose un área de captación de energía solar de 30 m2 que será entregada con diez colectores de tubos alvacío marca Thermomax, Modelo Solamax 30. In Ecuador there are many non-electrified remote areas, especially in the province of Pastaza, in this article a solar absorption cooling system is presented as an alternative for the air conditioning of a doctor's office (medical clinic in Community Kumay. The calculation of the estimated thermal load on the doctor's office is done using the software Carrier E20, which throws a necessity of cooling of 10 kW or 2,84 tons of refrigeration. The solar cooling system consist in an absorption machine of single effect, ClimateWell 10, with 10 kW of cooling power that uses as absorbent the lithium chloride and water pair, this system  required an area of reception of solar energy of 30 m2 that will be given with 10 vacuum tube collectors Thermomax, Model Solamax 30.

  4. Study of an absorption machine for an ammonia-water system ...

    African Journals Online (AJOL)

    This paper deals with Study of an absorption machine for an ammonia-water system decentralized trigeneration. The effects of evaporator, absorber and boiler temperature on the coefficient of performance of this cycle investigate. Simulation results show that with increasing the evaporator and absorber temperature the ...

  5. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1996-04-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

  6. Thermodynamic and economic studies of two new high efficient power-cooling cogeneration systems based on Kalina and absorption refrigeration cycles

    International Nuclear Information System (INIS)

    Rashidi, Jouan; Ifaei, Pouya; Esfahani, Iman Janghorban; Ataei, Abtin; Yoo, Chang Kyoo

    2016-01-01

    Highlights: • Proposing two new power and cooling cogeneration systems based on absorption chillers and Kalina cycles. • Model-based comparison through thermodynamic and economic standpoints. • Investigating sensitivity of system performance and costs to the key parameters. • Reducing total annual costs of the base system up to 8% by cogeneration. • Increasing thermal efficiency up to 4.9% despite of cooling generation. - Abstract: Two new power and cooling cogeneration systems based on Kalina cycle (KC) and absorption refrigeration cycle (AC) are proposed and studied from thermodynamic and economic viewpoints. The first proposed system, Kalina power-cooling cycle (KPCC), combines the refrigerant loop of the water-ammonia absorption chiller, consisting of an evaporator and two throttling valves with the KC. A portion of the KC mass flow enters the evaporator to generate cooling after being condensed in the KPCC system. KPCC is a flexible system adapting power and cooling cogeneration to the demand. The second proposed system, Kalina lithium bromide absorption chiller cycle (KLACC), consists of the KC and a single effect lithium bromide-water absorption chiller (AC LiBr-water ). The KC subsystem discharges heat to the AC LiBr-water desorber before condensing in the condenser. The performance and economic aspects of both proposed systems are analyzed and compared with the stand alone KC. A parametric analysis is conducted to evaluate the sensitivity of efficiencies and the generated power and cooling quantities to the key operating variables. The results showed that, thermal efficiency and total annual costs decreased by 5.6% and 8% for KPCC system but increased 4.9% and 58% for KLACC system, respectively. Since the power-cooling efficiency of KLACC is 42% higher than KPCC it can be applied where the aim is cooling generation without considering economic aspects.

  7. Promises of Machine Learning Approaches in Prediction of Absorption of Compounds.

    Science.gov (United States)

    Kumar, Rajnish; Sharma, Anju; Siddiqui, Mohammed Haris; Tiwari, Rajesh Kumar

    2018-01-01

    The Machine Learning (ML) is one of the fastest developing techniques in the prediction and evaluation of important pharmacokinetic properties such as absorption, distribution, metabolism and excretion. The availability of a large number of robust validation techniques for prediction models devoted to pharmacokinetics has significantly enhanced the trust and authenticity in ML approaches. There is a series of prediction models generated and used for rapid screening of compounds on the basis of absorption in last one decade. Prediction of absorption of compounds using ML models has great potential across the pharmaceutical industry as a non-animal alternative to predict absorption. However, these prediction models still have to go far ahead to develop the confidence similar to conventional experimental methods for estimation of drug absorption. Some of the general concerns are selection of appropriate ML methods and validation techniques in addition to selecting relevant descriptors and authentic data sets for the generation of prediction models. The current review explores published models of ML for the prediction of absorption using physicochemical properties as descriptors and their important conclusions. In addition, some critical challenges in acceptance of ML models for absorption are also discussed. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Refrigeration and global warming

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Some aspects of global warming in general, and the implications for refrigerants and refrigerator efficiency in particular, are briefly considered in a question and answer format. The concepts of Global Warming Potential (GWP) and Total Equivalent Warming Impact (TEWI) are explained. GWP is an index which allows a simple comparison to be make between the warming effects of different gases on a kg to kg basis relative to carbon. The GWP depends both on the lifetime of a substance in the atmosphere and its infra-red absorption capacity. The overall warming effect of operating a refrigeration system for its entire life is measured by its TEWI. Chloroflourocarbons (CFCs) which have been widely used as refrigerants are powerful greenhouse gases with high GWPs. Because of the bank of CFCs in refrigerating systems, their levels in the atmosphere are still increasing and it will be some time before refrigerant changes will be effective in reducing the warming effects of refrigerant releases. Hydrocarbons, hydroflourocarbons and ammonia all have a part to play as substitute refrigerants. Refrigerator efficiency is very important in terms of reducing CO 2 emissions. (UK)

  9. Overview of the use of refrigerating fluids in thermodynamical machines; Panorama de l`utilisation des fluides frigorigenes dans les machines thermodynamiques

    Energy Technology Data Exchange (ETDEWEB)

    Bernier, J. [Syrec SA (France)

    1996-12-31

    The R-22 refrigerant has been used as a substitute of chlorofluorocarbons in refrigerating machineries but its use will become prohibited very soon. This paper raises the problem of its replacement by other HFC or natural fluids. The problem of natural fluids like ammonia or propane concerns their toxicity, flammability and explosion risk. If a regulation about the greenhouse effect is defined, the performance of the installation will be the decisive parameter for the choice of a refrigerant. R-22 fluid has multiple applications from air-conditioning systems to freezing tunnels and the most suitable substitutes will be different from one application to the other. The different criteria that influence the choice of a refrigerating fluid are: the condensation pressure, the delivery temperature, the compressor volume efficiency, the volume refrigerating power, the coefficient of performance, the variation of vaporization temperature, the global greenhouse effect, the toxicity, flammability and explosive character. A comparison between several fluids has been performed with a single-stage airtight compressor of 10 m{sup 3}/h, at a 40 deg. C constant condensation temperature, a 5 deg. C overheating and a 3 deg. C under-cooling. (J.S.) 6 refs.

  10. Feasibility limits and performance of an absorption cooling machine using light alkane mixtures

    International Nuclear Information System (INIS)

    Dardour, H.; Mazouz, S.; Reneaume, J.-M.; Cézac, P.; Bourouis, M.; Bellagi, A.

    2015-01-01

    The performance of a heat-driven vapor absorption chiller with various alkane mixtures as working pairs was studied. A Thermodynamic analysis showed that under specified operating conditions and with a generator temperature below 130 °C, temperature achievable with a simple flat plate collector when solar energy is expected as the driving heat source, the application of some of the proposed alkane mixtures is not feasible. Simulations using ASPEN Plus flow sheeting program are then done with the selected working pairs. All simulations were done specifying the Peng-Robinson equation of state as the property method. A parametric study was carried out allowing the investigation of the generator temperature effect on the system performance and the comparison between performances released with each working pair. Results revealed that a water-cooled absorption machine using the C3H8/n-C9H20 pair as working fluid releases the best performances from a heat driving temperature level of about 100 °C. - Highlights: • Performance of an absorption chiller with various alkane mixtures was studied. • Some of the proposed alkane mixtures is not feasible. • Only the n-C4/n-C6 mixture may be considered for air-cooled machine. • In case of water cooling, C3/n-C9 and n-C4/n-C9 give the best COP

  11. Numerical simulation and experimental results of horizontal tube falling film generator working in a NH3-LiNO3 absorption refrigeration system

    International Nuclear Information System (INIS)

    Herrera, J.V.; Garcia-Valladares, O.; Gomez, V.H.; Best, R.

    2010-01-01

    This paper describes the work made at the Centro de Investigacion en Energia in the development of an absorption refrigeration system for cooling and refrigeration applications with a capacity of 10 kW. The single effect unit utilizes ammonia-lithium nitrate as working pair and it is air cooled. The generator is a falling film type with horizontal tubes where the heating oil flows inside the tube bank and the ammonia-lithium nitrate solution flows as a falling film on the tube outside, where it is heated and ammonia vapor is generated. The generator consists of tree columns and four rows per column of horizontal tubes. The system was tested at controlled conditions with heating oil obtained from an electric resistance heating loop. A numerical model of the horizontal falling film generator was developed that divided the system into three different thermal elements: the flow inside the tube, the heat conduction in the tube wall and the falling film solution flow. The mathematical model was tested and validated with experimental data and a study of the influence of the heat transfer coefficient for ammonia-lithium nitrate solution in the numerical model was carried out. A comparison between experimental and numerical data for the heat flux in the system and the temperature profiles in the oil and solution flows shown a good degree of correlation.

  12. Modeling of Artificial Neural Network for Predicting Specific Heat capacity of working fluid LiBr-H2O used in Vapor Absorption Refrigeration System

    Directory of Open Access Journals (Sweden)

    Dheerendra Vikram Singh

    2011-05-01

    Full Text Available The objective of this work is to model an artificial neural network (ANN to predict the value of specific heat capacity of working fluid LiBr-H2O used in vapour absorption refrigeration systems. A feed forward back propagation algorithm is used for the network, which is most popular for ANN. The consistence between experimental and ANN’s approach result was achieved by a mean relative error -0.00573, sum of the squares due to error0.00321, coefficient of multiple determination R-square 0.99961and root mean square error 0.01573 for test data. These results had been achieved in Matlab environment and the use of derived equations in any programmable language for deriving the specific heat capacity of LiBr-H2O solution.

  13. Calculation procedure to determine average mass transfer coefficients in packed columns from experimental data for ammonia-water absorption refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Sieres, Jaime; Fernandez-Seara, Jose [University of Vigo, Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, Vigo (Spain)

    2008-08-15

    The ammonia purification process is critical in ammonia-water absorption refrigeration systems. In this paper, a detailed and a simplified analytical model are presented to characterize the performance of the ammonia rectification process in packed columns. The detailed model is based on mass and energy balances and simultaneous heat and mass transfer equations. The simplified model is derived and compared with the detailed model. The range of applicability of the simplified model is determined. A calculation procedure based on the simplified model is developed to determine the volumetric mass transfer coefficients in the vapour phase from experimental data. Finally, the proposed model and other simple calculation methods found in the general literature are compared. (orig.)

  14. Performance analysis of absorption heat transformer cycles using ionic liquids based on imidazolium cation as absorbents with 2,2,2-trifluoroethanol as refrigerant

    International Nuclear Information System (INIS)

    Ayou, Dereje S.; Currás, Moisés R.; Salavera, Daniel; García, Josefa; Bruno, Joan C.; Coronas, Alberto

    2014-01-01

    Highlights: • TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) absorption heat transformer cycles are studied. • Influence of various operating conditions on cycle’s performance is investigated. • Performance comparisons with H 2 O + LiBr and TFE + TEGDME cycles are done. • Enthalpy data for TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) liquid mixtures are calculated. • TFE + [emim][BF 4 ] (or [bmim][BF 4 ]) cycles have higher gross temperature lift (GTL). - Abstract: A detailed thermodynamic performance analysis of a single-stage absorption heat transformer and double absorption heat transformer cycles using new working pairs composed of ionic liquids (1-ethyl-3-methylimidazolium tetrafluoroborate ([emim][BF 4 ]) and 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF 4 ])) as absorbent and 2,2,2-trifluoroethanol (TFE) as refrigerant has been studied. Several performance indicators were used to evaluate and compare the performance of the cycles using the TFE + [emim][BF 4 ] and TFE + [bmim][BF 4 ] working pairs with the conventional H 2 O + LiBr and organic TFE + TEGDME working pairs. The obtained results show that the ionic liquid based working pairs are suitable candidates to replace the conventional H 2 O + LiBr working pairs in order to avoid the disadvantages associated with it mainly crystallization and corrosion and also they perform better (higher gross temperature lift) than TFE + TEGDME working pair at several operating conditions considered in this work

  15. The use of absorption refrigeration systems in combined cycle power plants; Empleo de sistemas de refrigeracion por absorcion en plantas de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes, H.; Ambriz, J.J.; Vargas, M.; Godinez, M.; Gomez, F.; Valdez, L.; Pantoja, G. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Departamento de Ingenieria de Procesos e Hidraulica, Mexico D. F. (Mexico)

    1995-12-31

    Day after day the electric power generation tends to be done in the most efficient way in order to diminish the generation costs and the rate of environmental pollution per KWh generated. This paper discusses the application of absorption refrigeration systems for the cooling of the air entering the compressor of a gas turbine in a combined cycle, in order to increase the mass air flow and with it the turbine output. The flows with remanent energy content that are not used in a combined cycle can be used for the operation of the absorption refrigeration system. This way, the required thermal energy for the cooling system is free. With this system it is possible to raise the gas turbine generation output from 5% to 25%. [Espanol] La generacion electrica dia con dia pretende realizarse de la manera mas eficiente posible con el objeto de disminuir los costos de generacion y la tasa de contaminacion ambiental por Kwh generado. En el presente trabajo se introduce la aplicacion de sistemas de refrigeracion por absorcion para el enfriamiento del aire de entrada al compresor de la turbina de gas de un ciclo combinado, con el objeto de aumentar el flujo masico del aire y con ello la potencia de salida de la turbina. Las corrientes con contenido remanente de energia termica que no se usan en una planta de ciclo combinado pueden servir para operar el sistema de refrigeracion por absorcion. De esta manera, la energia termica requerida para el sistema de enfriamiento es gratuita. Con este sistema es posible incrementar la potencia de generacion de la turbina de gas de 5 a 25%.

  16. Corrosion and passivation behavior of various stainless steels in libr solution used in absorption-type refrigeration system

    International Nuclear Information System (INIS)

    Shahid, M.

    2007-01-01

    Various structural materials have been suggested for the refrigeration units to combat high corrosiveness of the absorbent. The corrosion behavior of three grades of austenitic stainless steels, have been investigated in lithium bromide (LiBr) solutions, using electrochemical techniques. Potentiodynamic E- log-i curves, potential-time scans and polarization resistance diagrams obtained by using three-electrode system connected to a computerized Gamry at the rate framework, have been used to analyze their corrosion and passivation behavior in various concentrations of LiBr i.e. commercial LiBr (850 g/J solution containing chromate inhibitor), 400 g/l LiBr and 700 g/J LiBr solutions, at room temperature. Relatively higher corrosion current was observed in SS304 exposed to inhibitor-free electrolyte compared to inhibited commercial solution. Inhibitor proved to be more efficient in case of AISI 304 as it showed significantly higher corrosion rate in un-inhibited solutions. (author)

  17. Exergy based parametric analysis of a combined reheat regenerative thermal power plant and water–LiBr vapor absorption refrigeration system

    International Nuclear Information System (INIS)

    Gogoi, T.K.; Talukdar, K.

    2014-01-01

    Highlights: • Exergy analysis of a combined power–absorption cooling system is provided. • Exergetic efficiency of the power cycle and absorption cooling system are calculated. • Irreversibility in each component and total system irreversibility are calculated. • Effect of operating parameters on exergetic performance and irreversibility is analyzed. • Optimum operating parameters are identified based on energy and exergy based results. - Abstract: In this paper, exergy analysis of a combined reheat regenerative steam turbine (ST) based power cycle and water–LiBr vapor absorption refrigeration system (VARS) is presented. Exergetic efficiency of the power cycle and VARS, energy utilization factor (EUF) of the combined system (CS) and irreversibility in each system component are calculated. The effect of fuel flow rate, boiler pressure, cooling capacity and VARS components’ temperature on performance, component and total system irreversibility is analyzed. The second law based results indicate optimum performance at 150 bar boiler pressure and VARS generator, condenser, evaporator and absorber temperature of 80 °C, 37.5 °C, 15 °C and 35 °C respectively. The present exergy based results conform well to the first law based results obtained in a previous analysis done on the same combined system. Irreversibility distribution among various power cycle components shows the highest irreversibility in the cooling tower. Irreversibility of the exhaust flue gas leaving the boiler and the boiler are the next major contributors. Among the VARS components, exergy destruction in the generator is the highest followed by irreversibility contribution of the absorber, condenser and the evaporator

  18. Absorption cooling device. Absorptions-Kuehlvorrichtung

    Energy Technology Data Exchange (ETDEWEB)

    Bourne, J.; Vardi, I.; Kimchi, Y.; Ben-Dror, J.

    1980-03-25

    The invention concerns improvements of absorption refrigerators, where a lithium chloride or lithium bromide/water cycle is used. According to the invention an inner separating or dividing structure between different functional parts of a machine of this type is provided. The structure contains two sections of wall, which are separated from one another by a suitable space, in order to achieve thermal insulation. This air space is provided with an opening in the direction towards the inside of the container and the opening is shielded to prevent the entry of liquids (in liquid or spray form).

  19. The application of machine learning to the modelling of percutaneous absorption: an overview and guide.

    Science.gov (United States)

    Ashrafi, P; Moss, G P; Wilkinson, S C; Davey, N; Sun, Y

    2015-01-01

    Machine learning (ML) methods have been applied to the analysis of a range of biological systems. This paper reviews the application of these methods to the problem domain of skin permeability and addresses critically some of the key issues. Specifically, ML methods offer great potential in both predictive ability and their ability to provide mechanistic insight to, in this case, the phenomena of skin permeation. However, they are beset by perceptions of a lack of transparency and, often, once a ML or related method has been published there is little impetus from other researchers to adopt such methods. This is usually due to the lack of transparency in some methods and the lack of availability of specific coding for running advanced ML methods. This paper reviews critically the application of ML methods to percutaneous absorption and addresses the key issue of transparency by describing in detail - and providing the detailed coding for - the process of running a ML method (in this case, a Gaussian process regression method). Although this method is applied here to the field of percutaneous absorption, it may be applied more broadly to any biological system.

  20. Refrigeration a history

    CERN Document Server

    Gantz, Carroll

    2015-01-01

    For thousands of years, humans coped with heat by harvesting and storing natural ice and devising natural cooling systems that utilized ventilation and evaporation. By the mid 1800s, people began developing huge refrigeration machines to manufacture ice. By the early 1900s, engineers developed electric domestic refrigerators, which by 1927 were affordable convenient household appliances. By then, an increasingly sophisticated public demanded more modern-looking appliances than engineers could produce, and a new breed of designers entered the manufacturing world to provide them. During the Depr

  1. NLP model of a LiBr–H2O absorption refrigeration system for the minimization of the annual operating cost

    International Nuclear Information System (INIS)

    Rubio-Maya, Carlos; Pacheco-Ibarra, J. Jesús; Belman-Flores, Juan M.; Galván-González, Sergio R.; Mendoza-Covarrubias, Crisanto

    2012-01-01

    In this paper the optimization of a LiBr–H 2 O absorption refrigeration system with the annual operating cost as the objective function to be minimized is presented. The optimization problem is established as a Non-Linear Programming (NLP) model allowing a formulation of the problem in a simple and structured way, and reducing the typical complexity of the thermal systems. The model is composed of three main parts: the thermodynamic model based on the exergy concept including also the proper formulation for the thermodynamic properties of the LiBr–H 2 O mixture, the second is the economic model and the third part composed by inequality constraints. The solution of the model is obtained using the CONOPT solver suitable for NLP problems (code is available on request). The results show the values of the decision variables that minimize the annual cost under the set of assumptions considered in the model and agree well with those reported in other works using different optimization approaches. - Highlights: ► The optimization of an ARS is presented using the annual operating cost as the objective function. ► The problem is established as an NLP model allowing a formulation in a simple and structured way. ► Several formulations for the thermodynamic properties were tested to implement the simpler ones. ► The results obtained agree well with those reported in the work being in comparison.

  2. Vapor pressure of heat transfer fluids of absorption refrigeration machines and heat pumps: Binary solutions of lithium nitrate with methanol

    International Nuclear Information System (INIS)

    Safarov, Javid T.

    2005-01-01

    Vapor pressure p of LiNO 3 + CH 3 OH solutions at T = (298.15 to 323.15) K was reported, osmotic φ and activity coefficients γ; and activity of solvent a s have been evaluated. The experiments were carried out in molality range m = (0.18032 to 5.2369) mol . kg -1 . The Antoine equation was used for the empiric description of experimental vapor pressure results. The Pitzer-Mayorga model with inclusion of Archer's ionic strength dependence of the third virial coefficient was used for the description of calculated osmotic coefficients. The parameters of Archer extended Pitzer model were used for evaluation of activity coefficients

  3. Testing and further development of a solar absorption cooling plant

    Science.gov (United States)

    Amannsberger, K.; Heckel, H.; Kreutmair, J.; Weber, K. H.

    1984-12-01

    Ammonia water absorption cooling units using the process heat of line-focusing solar collectors were developed and tested. Reduction of the evaporation temperature to minus 10 C; development of an air-cooled rectifying device for the refrigerant vapor; dry cooling of absorber and condenser by natural draft; refrigerating capacities of 14 to 10 kW which correspond to air temperatures of 25 to 40 C and 24 kW power consumption to heat the machine; auxiliary power requirement 450 W; full compatibility with changing heat input and air temperature, adaptation by automatic stabilization effects; and power optimization under changing boundary conditions by a simple regulating procedure independent of auxiliary power are achieved. The dynamic behavior of the directly linked collector-refrigeration machine system was determined. Operating conditions, market, and economic viability of solar cooling in third-world countries are described. Ice production procedures using absorption cooling units are demonstrated.

  4. Flammable refrigerants

    NARCIS (Netherlands)

    Gerwen, R.J.M. van; Verwoerd, M.; Oostendorp, P.A.

    1999-01-01

    Hydrocarbons are promising alternatives for CFC, HCFC and HFC refrigerants. Due to their flammable nature, safety aspects have to be considered carefully. The world-wide situation concerning acceptability and practical application of flammable refrigerants is becoming more and more complex and

  5. High-speed combustion diagnostics in a rapid compression machine by broadband supercontinuum absorption spectroscopy.

    Science.gov (United States)

    Werblinski, Thomas; Fendt, Peter; Zigan, Lars; Will, Stefan

    2017-05-20

    The first results under fired internal combustion engine conditions based on a supercontinuum absorption spectrometer are presented and discussed. Temperature, pressure, and water mole fraction are inferred simultaneously from broadband H 2 O absorbance spectra ranging from 1340 nm to 1440 nm. The auto-ignition combustion process is monitored for two premixed n-heptane/air mixtures with 10 kHz in a rapid compression machine. Pressure and temperature levels during combustion exceed 65 bar and 1900 K, respectively. To allow for combustion measurements, the robustness of the spectrometer against beam steering has been improved compared to its previous version. Additionally, the detectable wavelength range has been extended further into the infrared region to allow for the acquisition of distinct high-temperature water transitions located in the P-branch above 1410 nm. Based on a theoretical study, line-of-sight (LOS) effects introduced by temperature stratification on the broadband fitting algorithm in the complete range from 1340 nm to 1440 nm are discussed. In this context, the recorded spectra during combustion were evaluated only within a narrower spectral region exhibiting almost no interference from low-temperature molecules (here, P-branch from 1410 nm to 1440 nm). It is shown that this strategy mitigates almost all of the LOS effects introduced by cold molecules and the evaluation of the spectrum in the entirely recorded wavelength range at engine combustion conditions.

  6. Vaccine refrigeration

    Science.gov (United States)

    McColloster, Patrick J; Martin-de-Nicolas, Andres

    2014-01-01

    This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator regulator with a battery back-up power supply and microprocessor control system is also described. PMID:24442209

  7. Stationary Refrigeration

    Science.gov (United States)

    Resources for HVACR contractors, technicians, equipment owners and other regulated industry to check rules and requirements for managing refrigerant emissions, information on how to become a certified technician, and compliance assistance documents.

  8. Measurement of properties of a lithium bromide aqueous solution for the determination of the concentration for a prototype absorption machine

    International Nuclear Information System (INIS)

    Labra, L.; Juárez-Romero, D.; Siqueiros, J.; Coronas, A.; Salavera, D.

    2017-01-01

    Highlights: • Determination of concentration of absorption mixture for absorption heat transformers. • Measurement of physical properties for heat transformer assessment. • Comparative behavior of Electric conductivity, Refractive index, and density of LiBr-H 2 O. - Abstract: An electrolyte solution of Lithium Bromide (LiBr) water was chosen for study because of its wide use in prototype absorption machines. The LiBr must be operated close to the temperature and mass fraction at which lithium bromide achieves the highest efficiency. For the purpose of establishing the concentration in a prototype absorption machines, measurements were made of the properties that vary with temperature and concentration. The selected properties are electrical conductivity, density, refractive indexes and sound velocity. The resulting measured properties values were compared with some values found in previous works. The properties of aqueous lithium bromide solutions were measured at the concentration range of 45–65% of LiBr and temperatures range of 20–80 °C. Semi-empirical correlations that determine the properties of lithium bromide are also proposed. The methods for measuring the properties of aqueous solutions were considered taking into account their reliability, simplicity and sampling time.

  9. Conversion of cold beverage dispenser's refrigeration system to R744 refrigerant

    OpenAIRE

    Visek, Matej; Elbel, Stefan; Hrnjak, Pega

    2016-01-01

    Cold beverage dispensers belong to the group of light commercial refrigeration machines that includes beverage coolers, ice machines and storage units for food items. Beverage dispensers use a vapor compression system to charge a thermal storage, usually an ice bank, which is used to indirectly cool tap water and beverage concentrate. For these machines, R290 (propane) and R744 (carbon dioxide) are among the favorite candidates to completely replace high GWP HFC refrigerants in the future. Be...

  10. Development of a dual purpose refrigeration system for domestic use

    African Journals Online (AJOL)

    This paper is aimed at the design and construction of a dual purpose domestic refrigeration system, that can simultaneously function as a refrigerator and as well as an air conditioner henceforth known as REFACON. The refrigeration system employed was a vapour compression system. The machine was a split ...

  11. Thermoacoustic refrigerator for space applications

    Science.gov (United States)

    Garrett, Steven L.; Adeff, Jay A.; Hofler, Thomas J.

    1993-10-01

    A new spacecraft cryocooler which uses resonant high-amplitude sound waves in inert gases to pump heat is described. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). A space-qualified thermoacoustic refrigerator was flown on the Space Shuttle Discovery (STS-42) in January, 1992. It was entirely autonomous, had no sliding seals, required no lubrication, used mostly low-tolerance machined parts, and contained no expensive components. Thermoacoustics is shown to be a competitive candidate for food refrigerator/freezers and commercial/residential air conditioners. The design and performance of the Space Thermo/Acoustic Refrigerator (STAR) is described.

  12. Cogeneration with gas turbine associated to the absorption refrigeration system: a computer program for exergy economics analysis; Cogeracao com turbina a gas associada ao sistema de refrigeracao por absorcao: um programa computacional para analise exergoeconomica

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Julio Santana [UNESP, Guaratingueta, SP (Brazil). Faculdade de Engenharia. Dept. de Matematica] E-mail: santana@feg.unesp.br; Silveira, Jose Luz; Balestieri, Jose Antonio Perrella [UNESP, Guaratingueta, SP (Brazil). Faculdade de Engenharia. Dept. de Energia

    2000-07-01

    This paper presents the development of a computer program for exergy and economic analysis of cogeneration systems applying gas turbine associated to the absorption refrigeration system. The computer program selects gas turbine systems viewing the operation under thermal parity through a data base composed by gas turbines commercially available in the market, under the ISO (International Standard Organization). The computer program corrects the system performance parameters selected for the installation local conditions. The exergy and economic analysis are made based on the lowest exergy manufacturing cost where the best system is considered. A case study of the computer program application is presented.

  13. United States: refrigeration industry blows hot

    International Nuclear Information System (INIS)

    Crawford, J.

    1997-01-01

    In the framework of the Kyoto convention on global warming, the american refrigeration industries have undertaken several organizations and contacts with governments and agencies in order to explain the real issues concerning the effects of refrigerant utilization in refrigerating machines on the greenhouse effect, taking into consideration the commercial impact that a ban on certain refrigerants could have on the industry's business. They argue that HFC utilization in this industry is fundamentally non-emissive and that important improvements have been realized concerning tightness and energy consumption

  14. Refrigeration Showcases

    Science.gov (United States)

    1997-01-01

    Through the Technology Affiliates Program at the Jet Propulsion Laboratory (JPL), valuable modifications were made to refrigerator displays built by Displaymor Manufacturing Company, Inc. By working with JPL, Displaymor could address stiffer requirements that ensure the freshness of foods. The application of the space technology meant that the small business would be able to continue to market its cases without incurring expenses that could threaten the viability of the business, and the future of several dozen jobs. Research and development improvements in air flow distribution and refrigeration coil technology contributed greatly to certifying Displaymor's showcases given the new federal regulations. These modifications resulted in a refrigerator case that will keep foods cooler, longer. Such changes maintained the openness of the display, critical to customer visibility and accessibility, impulse buying, and cross-merchandising.

  15. Theoretical study and design of a low-grade heat-driven pilot ejector refrigeration machine operating with butane and isobutane and intended for cooling of gas transported in a gas-main pipeline

    KAUST Repository

    Petrenko, V.O.

    2011-11-01

    This paper describes the construction and performance of a novel combined system intended for natural gas transportation and power production, and for cooling of gas transported in a gas-main pipeline. The proposed system includes a gas turbine compressor, a combined electrogenerating plant and an ejector refrigeration unit operating with a hydrocarbon refrigerant. The combined electrogenerating plant consists of a high-temperature steam-power cycle and a low-temperature hydrocarbon vapor power cycle, which together comprise a binary vapor system. The combined system is designed for the highest possible effectiveness of power generation and could find wide application in gas-transmission systems of gas-main pipelines. Application of the proposed system would enable year-round power generation and provide cooling of natural gas during periods of high ambient temperature operation. This paper presents the main results of a theoretical study and design performance specifications of a low-grade heat-driven pilot ejector refrigeration machine operating with butane and isobutane. © 2010 Elsevier Ltd and IIR. All rights reserved.

  16. Recent investigations on refrigerants for magnetic refrigerators

    International Nuclear Information System (INIS)

    Hashimoto, T.

    1986-01-01

    In development of the magnetic refrigerator, an important problem is selection of magnetic materials as refrigerants. The main purpose of the present paper is to discuss the magnetic and thermal properties necessary for these refrigerants and to report recent investigations. Magnetic refrigerants can be expediently divided into two groups, one for the Carnottype magnetic refrigerator below 20 K and the other for the Ericsson-type refrigerator. The required physical properties of refrigerants in each type of the magnetic refrigerator are first discussed. And then, the results of recent investigations on the magnetic, thermal and magnetocaloric characters of several promising magnetic refrigerants are shown. Finally, a brief prospect of the magnetic refrigerants and refrigerators is given

  17. Refrigeration Servicing.

    Science.gov (United States)

    Hamilton, Donald L.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the services required to be performed on refrigeration equipment. The course contains four study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the unit. The study units are divided into numbered work…

  18. Ammonia and ammonium hydroxide sensors for ammonia/water absorption machines: Literature review and data compilation

    Science.gov (United States)

    Anheier, N. C., Jr.; McDonald, C. E.; Cuta, J. M.; Cuta, F. M.; Olsen, K. B.

    1995-05-01

    This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. Pacific Northwest Laboratory (PNL) researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation, sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH4(+)). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.

  19. Ammonia and ammonium hydroxide sensors for ammonia/water absorption machines: Literature review and data compilation

    Energy Technology Data Exchange (ETDEWEB)

    Anheier, N.C. Jr.; McDonald, C.E.; Cuta, J.M.; Cuta, F.M.; Olsen, K.B.

    1995-05-01

    This report describes an evaluation of various sensing techniques for determining the ammonia concentration in the working fluid of ammonia/water absorption cycle systems. The purpose of this work was to determine if any existing sensor technology or instrumentation could provide an accurate, reliable, and cost-effective continuous measure of ammonia concentration in water. The resulting information will be used for design optimization and cycle control in an ammonia-absorption heat pump. PNL researchers evaluated each sensing technology against a set of general requirements characterizing the potential operating conditions within the absorption cycle. The criteria included the physical constraints for in situ operation, sensor characteristics, and sensor application. PNL performed an extensive literature search, which uncovered several promising sensing technologies that might be applicable to this problem. Sixty-two references were investigated, and 33 commercial vendors were identified as having ammonia sensors. The technologies for ammonia sensing are acoustic wave, refractive index, electrode, thermal, ion-selective field-effect transistor (ISFET), electrical conductivity, pH/colormetric, and optical absorption. Based on information acquired in the literature search, PNL recommends that follow-on activities focus on ISFET devices and a fiber optic evanescent sensor with a colormetric indicator. The ISFET and fiber optic evanescent sensor are inherently microminiature and capable of in situ measurements. Further, both techniques have been demonstrated selective to the ammonium ion (NH{sub 4}{sup +}). The primary issue remaining is how to make the sensors sufficiently corrosion-resistant to be useful in practice.

  20. 2017 German refrigeration and air conditioning meeting. Proceedings

    International Nuclear Information System (INIS)

    2017-01-01

    This year's lecture programme includes 117 presentations in the five working departments of DKV and 10 lectures at the special event ''Energy-efficient air conditioning in data centres''. The main topics in the respective departments were: (1) Cryogenics: Space applications; Cryogenic plants; Cryomedicine and cryobiology; Components, developments; Processes and plants; Valves, design. (2) Basics: Evaporation, material values; evaporation, condensation; absorption; adsorption, latent storage; cycle simulation. (3) Components: CO 2 plant engineering and components; refrigerants; process control, adsorption, sublimation and storage technology; refrigerating machine oils, heat exchangers and corrosion; components 4.0, sensors and control technology; simulation of plant processes. (4) Cold application: Application; Application / Natural Refrigerants; Mobile Applications Car; Mobile Applications; Supermarket / Efficiency; Optimization / Efficiency. (5) Air conditioning and heat pump applications: load shifting, smart home, flexibility; heat sources and industrial heat pumps; modelling, simulations; energy concepts heat pumps and photovoltaics; monitoring, evaluation; technology trends / working materials. Six papers are separately analyzed for this database. [de

  1. Development of Exhaust Gas Driven Absorption Chiller-Heater

    Science.gov (United States)

    Inoue, Naoyuki; Endou, Tetsuya; Saito, Kiyoshi; Kawai, Sunao

    Micro gas turbines are expected as engines for the distributed co-generation systems, performing power generation and heat recovery. Waste heat from micro gas turbines are discharged in the form of exhaust gas, and it is simple that exhaust gas is directly supplied to an absorption refrigerator. In this paper, we evaluated various single-double effect absorption cycles for exhaust gas driven absorption refrigerators, and clarified that the difference of performance among these cycles are little. We adopted one of these cycles for the prototype machine, and experimented with it to get the partial load characteristics and the effect of cooling water temperature on the performance. Based on the experimental data, we developed as imulation model of the static characteristics, and studied the direction of improvement.

  2. High-efficiency absorption-type heat pumps and refrigerators. From topology to the pilot plant; Hocheffiziente Absorptionsmaschinen zur Versorgung mit Kaelte und Waerme. Von der Topologie zur Pilotanlage

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, F.; Demmel, S.; Lamp, P. [Bayerisches Zentrum fuer Angewandte Energieforschung e.V. (ZAE Bayern), Wuerzburg (Germany); Kahn, R. [Technische Univ. Muenchen (Germany). Physik Dept. E19; Alefeld, G.

    1998-12-31

    Absorption-type heat pumps or refrigerators are systems operated with heat. They have been known for a long time and are frequently used especially in airconditioning in the USA and south-east Asia. However, the conventional technique used is subject to many physical limitations, restricting their broader use. The paper demonstrates ways of overcoming these restrictions, for instance by multi-stage design. The exploitation of topological principles much facilitates the synthesis of novel circuits. The technical relevance of such developments is demonstrated by means of selected examples of executed laboratory and pilot plants. Modern absorption technology saves resources and prevents environmental pollution by consuming less fossil energy compared with the conventional technique, for instance by harnessing the thermal potential of solar energy or utilizing waste heat and residual heat, and, not least, thanks to the use of natural refrigerants. (orig.) [Deutsch] Absorptionswaermepumpen oder -kaeltemaschinen sind durch Waerme angetriebene Anlagen, die seit langem bekannt sind und besonders in der Klimatechnik in den USA und im suedostasiatischen Raum haeufig eingesetzt werden. Die dabei verwendete konventionelle Technik unterliegt allerdings vielfaeltigen physikalischen Einschraenkungen, die ihre noch breitere Anwendung verhindern. Es wird gezeigt, wie diese Einschraenkungen beispielsweise durch Mehrstufigkeit ueberwunden werden koennen. Durch die Verwendung topologischer Grundsaetze wird die Synthese neuartiger Kreislaeufe stark vereinfacht. Die technische Bedeutung solcher Entwicklungen wird an ausgewaehlten Beispielen ausgefuehrter Labor- und Pilotanlagen gezeigt. Durch den im Vergleich zu konventioneller Technik geringeren Verbrauch an fossiler Energie, beispielsweise durch die thermische Nutzung von Sonnenenergie oder durch die Nutzung von Ab- oder Restwaerme und nicht zuletzt durch die Verwendung natuerlicher Kaeltemittel werden bei Einsatz moderner

  3. Wave propagation and absorption in the electron cyclotron frequency range for TCA and TCV machines

    International Nuclear Information System (INIS)

    Cardinali, A.

    1990-01-01

    The main theoretical aspects of the propagation and absorption of electron cyclotron frequency waves are reviewed and applied to TCA and TCV tokamak plasmas. In particular the electromagnetic cold dispersion relation is solved analytically and numerically in order to recall the basic properties of mode propagation and to calculate the ray-trajectories by means of geometric optics. A numerical code which integrates the coupled first order differential ray-equations, has been developed and applied to the cases of interest. (author) 4 figs., 23 refs

  4. Time-resolved temperature measurements in a rapid compression machine using quantum cascade laser absorption in the intrapulse mode

    KAUST Repository

    Nasir, Ehson Fawad

    2016-07-16

    A temperature sensor based on the intrapulse absorption spectroscopy technique has been developed to measure in situ temperature time-histories in a rapid compression machine (RCM). Two quantum-cascade lasers (QCLs) emitting near 4.55μm and 4.89μm were operated in pulsed mode, causing a frequency "down-chirp" across two ro-vibrational transitions of carbon monoxide. The down-chirp phenomenon resulted in large spectral tuning (δν ∼2.8cm-1) within a single pulse of each laser at a high pulse repetition frequency (100kHz). The wide tuning range allowed the application of the two-line thermometry technique, thus making the sensor quantitative and calibration-free. The sensor was first tested in non-reactive CO-N2 gas mixtures in the RCM and then applied to cases of n-pentane oxidation. Experiments were carried out for end of compression (EOC) pressures and temperatures ranging 9.21-15.32bar and 745-827K, respectively. Measured EOC temperatures agreed with isentropic calculations within 5%. Temperature rise measured during the first-stage ignition of n-pentane is over-predicted by zero-dimensional kinetic simulations. This work presents, for the first time, highly time-resolved temperature measurements in reactive and non-reactive rapid compression machine experiments. © 2016 Elsevier Ltd.

  5. REACH. Refrigeration Units.

    Science.gov (United States)

    Snow, Rufus; And Others

    As a part of the REACH (Refrigeration, Electro-Mechanical, Air-Conditioning, Heating) electromechanical cluster, this student manual contains individualized instructional units in the area of refrigeration. The instructional units focus on refrigeration fundamentals, tubing and pipe, refrigerants, troubleshooting, window air conditioning, and…

  6. Influence of the speed of turn in the rotating machines of absorption (Part I); Influencia de la velocidad de giro en las maquinas rotativas de absorcion (Parte I)

    Energy Technology Data Exchange (ETDEWEB)

    Monne, C.; Guallar, J.; Alonso, S.; Palacin, F.

    2008-07-01

    A type of machine of absorption of simple effect of Br Li-H{sub 2}O this characterized to realise the thermodynamic cycle inside a closing that turns continuously. The present article studies the effect that has the turn in the different thermodynamic variables: Teg Vs. COP, Pref, Psol y Tse. (Author)

  7. Influence of the speed of turn in the rotating machines of absorption (Part II); Influencia de la velocidad de giro en las maquinas rotativas de absorcion (Parte II)

    Energy Technology Data Exchange (ETDEWEB)

    Monne, C.; Guallar, J.; Alonso, S.; Palacin, F.

    2008-07-01

    A type of machine of absorption of simple effect of Br Li-H{sub 2}O this characterized to realise the thermodynamic cycle inside a closing that turns continuously. The present article studies the effect that has the turn in the different thermodynamic variables: Tamb Vs. COP, Pref, y Tse. (Author)

  8. Refrigeration generation using expander-generator units

    Science.gov (United States)

    Klimenko, A. V.; Agababov, V. S.; Koryagin, A. V.; Baidakova, Yu. O.

    2016-05-01

    The problems of using the expander-generator unit (EGU) to generate refrigeration, along with electricity were considered. It is shown that, on the level of the temperatures of refrigeration flows using the EGU, one can provide the refrigeration supply of the different consumers: ventilation and air conditioning plants and industrial refrigerators and freezers. The analysis of influence of process parameters on the cooling power of the EGU, which depends on the parameters of the gas expansion process in the expander and temperatures of cooled environment, was carried out. The schematic diagram of refrigeration generation plant based on EGU is presented. The features and advantages of EGU to generate refrigeration compared with thermotransformer of steam compressive and absorption types were shown, namely: there is no need to use the energy generated by burning fuel to operate the EGU; beneficial use of the heat delivered to gas from the flow being cooled in equipment operating on gas; energy production along with refrigeration generation, which makes it possible to create, using EGU, the trigeneration plants without using the energy power equipment. It is shown that the level of the temperatures of refrigeration flows, which can be obtained by using the EGU on existing technological decompression stations of the transported gas, allows providing the refrigeration supply of various consumers. The information that the refrigeration capacity of an expander-generator unit not only depends on the parameters of the process of expansion of gas flowing in the expander (flow rate, temperatures and pressures at the inlet and outlet) but it is also determined by the temperature needed for a consumer and the initial temperature of the flow of the refrigeration-carrier being cooled. The conclusion was made that the expander-generator units can be used to create trigeneration plants both at major power plants and at small energy.

  9. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-07-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  10. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1999-01-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  11. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1996-11-15

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  12. Application of Cascade Refrigeration System with Mixing Refrigerant in Cold Air Cutting

    Science.gov (United States)

    Yang, Y.; Tong, M. W.; Yang, G.; Wang, X. P.

    In the mechanical cutting process, the replacement of traditional cutting solution with cold air can avoid the pollution of environment. In order to high efficient the refrigerating device and flexible adjust the temperature of cold air, it is necessary to use cascade refrigeration system to supply cool quantity for the compressed air. The introduction of a two-component non-azeotropic mixing refrigerant into the cryogenic part of the cascade system, can effectively solve the problems of the system working at too high pressure and the volume expanding of refrigerant in case of the cascade refrigeration sets closed down. However, the filling ratio of mixing refrigerants impact on the relationships among the closing down pressure, refrigerating output and refrigerating efficiency. On the basis of computing and experiment, the optimal mixing ratio of refrigerant R22/R13 and a low temperature of -60° were obtained in this study. A cold air injecting device possessing high efficiency in energy saving has also been designed and manufactured. The cold air, generated from this cascade system and employed in a cutting process, takes good comprehensive effects on machining and cutting.

  13. Optimization study of a single-effect water–lithium bromide absorption refrigeration system powered by flat-plate collector in hot regions

    International Nuclear Information System (INIS)

    Saleh, A.; Mosa, M.

    2014-01-01

    Highlights: • A comprehensive analysis for optimizing solar absorption system in hot region. • The most important parameter to be controlled is hot source temperature. • Ensuring appropriate choice of parameters, COP of absorption unit exceeds 0.8. • Results show that solar cooling systems are promising in hot regions. • The research aims to play a vital role to promote the use of renewable energy. - Abstract: This investigation has been carried out to present a comprehensive analysis for optimizing the operation of solar absorption system in hot regions. To optimize performance of the system, the hot source temperature should be controlled in function of incident solar radiation, chilled and cooling water temperatures. With an appropriate control, these external conditions can be monitored to detect and implement the actual optimization conditions. Adopting typical values encountered in hot regions, the overall system performance takes its optimal value at temperatures between 75 and 80 °C. It was found that in designing or selecting solar collector, selective coating type is necessary to produce hot water with potential around 80–90 °C needed to optimize operation of absorption unit. By ensuring an appropriate choice of components temperatures, COP of absorption unit can exceed the value 0.8. Cooling water temperature above 40 °C reduces significantly the performance of the unit which requires, under conditions of extremely high external temperatures, dimensioning and selection of condensers and absorbers that guarantee values less than this limit

  14. In-situ neutron investigation of hydrogen absorption kinetics in La(FexSi1-x)13 magnetocaloric alloys for room-temperature refrigeration application

    Science.gov (United States)

    Hai, Xueying; Mayer, Charlotte; Colin, Claire V.; Miraglia, Salvatore

    2016-02-01

    Promising magnetocaloric material La(Fe,Si)13 with a first-order magnetic transition has been widely investigated. The observed instability of hydrogen in the material is detrimental for its industrial upscale and a better control of the hydrogen absorption/desorption is necessary to optimize its application potential. In this article, the hydrogen absorption kinetics is studied through an in-situ neutron diffraction experiment. The results allow us to have an inside look at the structure "breathing" to accommodate the interstitial atoms and compare the effect of hydrides with carbohydrides.

  15. Method and refrigerants for replacing existing refrigerants in centrifugal compressors

    International Nuclear Information System (INIS)

    Kopko, W.L.

    1991-01-01

    This patent describes a method for replacing an existing refrigerant in a centrifugal compressor. It comprises selecting a desired impeller Mach number for the centrifugal compressor; selecting a base refrigerant constituent; combining at least one additive refrigerant constituent with the base refrigerant constituent to form a replacement refrigerant having at least one physical or chemical property different from the existing refrigerant and substantially providing the desired impeller Mach number in the centrifugal compressor; and replacing the existing refrigerant with the replacement refrigerant

  16. Open cycle liquid desiccant dehumidifier and hybrid solar/electric absorption refrigeration system. Annual report, January 1993--December 1993. Calendar year 1993

    Energy Technology Data Exchange (ETDEWEB)

    Nimmo, B.G.; Thornbloom, M.D.

    1995-04-01

    This annual report presents work performed during calendar year 1993 by the Florida Solar Energy Center under contract to the US Department of Energy. Two distinctively different solar powered indoor climate control systems were analyzed: the open cycle liquid desiccant dehumidifier, and an improved efficiency absorption system which may be fired by flat plate solar collectors. Both tasks represent new directions relative to prior FSEC research in Solar Cooling and Dehumidification.

  17. Closed Cycle Solar Refrigeration with the Calcium Chloride System ...

    African Journals Online (AJOL)

    A closed cycle solid absorption intermittent refrigerator, using CaC12 absorbent and NH3 refrigerant, was constructed and tested to obtain the instantaneous and cumulative available overall COP. The combined collector/absorber/generator unit had double glazing of 1.14 m2 exposed areas. The system was fitted with a ...

  18. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1994-05-27

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

  19. REFRIGERANT/LUBRICANT MIXTURES: PROBLEMS OF APPLICATION AND PROPERTY RESEARCH

    Directory of Open Access Journals (Sweden)

    Yu. Semenyuk

    2013-10-01

    Full Text Available The results and generalizations of thermophysical property research for the refrigerant/lubricant mixtures are summarized. The methodological aspects of the experimental studies of the thermal properties of real working media for vapor compression refrigeration machines and the general principles of the thermodynamic properties simulation for such solutions are analyzed. It is shown that the admixtures of compressor oil in the refrigerant make the efficiency parameters of compressor systems much lower. The question of a selective solubility of the multicomponent refrigerants in compressor oils is discussed.

  20. Refrigerants for Vapour Compression Refrigeration Systems

    Indian Academy of Sciences (India)

    tion system, refrigerant, ozone depletion, global warming, CFC,. HCFC, HFC, HFO, zeotropic mixture, natural fluids. With the mandate of Montreal Protocol banning ozone de- pleting substances, and Kyoto Protocol later on curtailing the use of substances which contribute to global warming, con- ventional refrigerants are to ...

  1. Refrigerants for Vapour Compression Refrigeration Systems

    Indian Academy of Sciences (India)

    Since then, the refrigeration technology has grown tremen- dously .... Montreal Protocol. (See Box 1). This has led to a renewed interest in the refrigerators operating on the Lorenz–Meutzner cycle. Figure 4. The shaded area .... In fact, man and animals emit significant amounts of GHGs due to their metabolic activity.

  2. Development of Magnetic Refrigerator

    Science.gov (United States)

    Ogiwara, Hiroyasu; Nakagome, Hideki; Kuriyama, Tohru

    A series of R & D of magnetic refrigerators has been done in order to realize an advanced type cryocooler for superconducting magnets of maglev trains and MRI medical system. As a result of efforts on both the magnetic refrigerator and superconducting magnets, a parasitic type magnetic refrigeration system was proposed.

  3. Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air conditioning technology workshop

    Energy Technology Data Exchange (ETDEWEB)

    1994-09-01

    Sessions included: HFC blown polyurethanes, carbon dioxide blown foam and extruded polystyrenes, plastic foam insulations, evacuated panel insulation, refrigeration and air conditioning, absorption and adsorption and stirling cycle refrigeration, innovative cooling technologies, and natural refrigerants. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  4. Performance analysis of single stage libr-water absorption machine operated by waste thermal energy of internal combustion engine: Case study

    Science.gov (United States)

    Sharif, Hafiz Zafar; Leman, A. M.; Muthuraman, S.; Salleh, Mohd Najib Mohd; Zakaria, Supaat

    2017-09-01

    Combined heating, cooling, and power is also known as Tri-generation. Tri-generation system can provide power, hot water, space heating and air -conditioning from single source of energy. The objective of this study is to propose a method to evaluate the characteristic and performance of a single stage lithium bromide-water (LiBr-H2O) absorption machine operated with waste thermal energy of internal combustion engine which is integral part of trigeneration system. Correlations for computer sensitivity analysis are developed in data fit software for (P-T-X), (H-T-X), saturated liquid (water), saturated vapor, saturation pressure and crystallization temperature curve of LiBr-H2O Solution. Number of equations were developed with data fit software and exported into excel work sheet for the evaluation of number of parameter concerned with the performance of vapor absorption machine such as co-efficient of performance, concentration of solution, mass flow rate, size of heat exchangers of the unit in relation to the generator, condenser, absorber and evaporator temperatures. Size of vapor absorption machine within its crystallization limits for cooling and heating by waste energy recovered from exhaust gas, and jacket water of internal combustion engine also presented in this study to save the time and cost for the facilities managers who are interested to utilize the waste thermal energy of their buildings or premises for heating and air conditioning applications.

  5. Reciprocating magnetic refrigerator

    Science.gov (United States)

    Johnson, D. L.

    1985-05-01

    A 4 to 15 K magnetic refrigerator to test as an alternative to the Joule-Thomson circuit as the low temperature stage of a 4 to 300 K closed-cycle refrigerator was developed. The reciprocating magnetic refrigerator consists of two matrices of gadolinium gallium garnet spheres located in tandem on a single piston which alternately moves each matrix into a 7 telsa magnetic field. A separate helium gas circuit is used as the heat exchange mechanism for the low and the high temperature extremes of the magnetic refrigerator. Details of the design and results of the initial refrigerator component tests are presented.

  6. Natural refrigerants. Future heat pumps for district heating; Naturliga koeldmedier. Framtida vaermepumpar foer fjaerrvaerme

    Energy Technology Data Exchange (ETDEWEB)

    Ingvarsson, Paul; Steen Ronnermark, Ingela [Fortum Teknik och Miljoe AB, Stockholm (Sweden); Eriksson, Marcus [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Chemical Engineering and Environmental Science

    2004-01-01

    International work on refrigerants is aiming at phasing out HFC. The solution might be natural refrigerants. Within 15-20 years, when present heat pumps for district heating in Sweden are likely not in service any longer, it might still be good economy to install new heat pumps since only the machines need to be replaced. This report describes the possibilities to use natural refrigerants. A first screening resulted in further study on some hydrocarbons, ammonia and carbon dioxide. Water was considered to require too large volumes. In present plants it is practically not possible to use any natural refrigerants, partly because the compressors are not adapted. In new plants the situation is different. Today it is technically possible to install new heat pumps in the studied size, 15 MW{sub th}, using ammonia or hydrocarbons as refrigerant. But likely it is very difficult to get permits from authorities since the refrigerants are toxic or highly flammable. There is substantial international research on using carbon dioxide, and this refrigerant is also used in some applications. Carbon dioxide is used at high pressure and in a trans-critical process. Surprisingly, it turned out that one compressor manufacturer considers it possible to supply a heat pump for district heating within 5 years. This development has taken place in Russia, mainly for domestic use. Thus, within 15 to 20 years there will probably exist a technique where carbon dioxide is used. However, more development is needed. Additionally, low district heating return temperatures are also needed to get an acceptable COP. The investment cost for a heat pump installation is considered to be approx. 30 % higher when using ammonia or propane compared to using R134a. When using carbon dioxide there is in the longer run potential to get lower cost than for R134a. The COPs are almost identical if the systems are properly designed. In the carbon dioxide case the COP is somewhat lower, but has a potential for

  7. Laser machining of advanced materials

    CERN Document Server

    Dahotre, Narendra B

    2011-01-01

    Advanced materialsIntroductionApplicationsStructural ceramicsBiomaterials CompositesIntermetallicsMachining of advanced materials IntroductionFabrication techniquesMechanical machiningChemical Machining (CM)Electrical machiningRadiation machining Hybrid machiningLaser machiningIntroductionAbsorption of laser energy and multiple reflectionsThermal effectsLaser machining of structural ceramicsIntrodu

  8. Energy conservation in refrigerating machines by combining of thermo-static expansion valve and interior heat transfer material; Energieeinsparung in Kaelteanlagen durch Kombination von thermostatischem Expansionsventil und innerem Waermeuebertrager

    Energy Technology Data Exchange (ETDEWEB)

    Tambovtsev, Alexander

    2007-12-15

    The invention of the refrigerating machine enables to generate cold energy in any needed amount and at any desired temperature. However, cold energy generation requires driving energy. The target of this dissertation is to reduce the energy consumption of refrigerating plants considerably by means of an intelligent combination of the thermo-static expansion valve and the interior heat transfer medium. This combination should not deteriorate the reliability nor incur additional costs. Until today the two known components thermo-static expansion valve and interior heat transfer medium are considered as incompatible, because the simple connection of both components leads to an unstable control behaviour. After a detailed analysis of the causes for this instability the hypothesis is made, a stable working area can be found by means of a deliberate ''deterioration'' of the internal heat transfer medium. This ''deterioration'' can be e.g. a bypass of a part of the high-pressure flow or a parallel flow arrangement of the flows in the heat transfer medium. This hypothesis was primarily proved by experiments, but also by simulation calculations. A test stand was set-up for this purpose, which was used to test various configurations and control strategies. A considerable reduction of the energy consumption compared to conventional arrangements was achieved. (orig.) [German] Die Erfindung der Kaeltemaschine macht es moeglich, dass heute zu beliebiger Zeit Kaelte in benoetigter Menge und gewuenschter Temperatur erzeugt werden kann. Aber fuer die Kaelteerzeugung braucht man Antriebsenergie. Das Ziel dieser Doktorarbeit besteht darin, mit einer intelligenten Kombination von thermostatischem Expansionsventil (TEV) und innerem Waermeuebertrager (IWUe) den Energieverbrauch von Kaelteanlagen deutlich zu verringern, ohne dass dies zu einer Verschlechterung der Zuverlaessigkeit oder wesentlichen Mehrkosten fuehrt. Bis heute gelten die beiden

  9. Refrigerants for Vapour Compression Refrigeration Systems

    Indian Academy of Sciences (India)

    ; global warming; CFC; HCFC; HFC; HFO; zeotropic mixture; natural fluids. Author Affiliations. G Venkatarathnam1 S Srinivasa Murthy1. Refrigeration and Airconditioning Laboratory, Department of Mechanical Engineering, Indian Institute of ...

  10. Experimental study of refrigeration performance based on linear Fresnel solar thermal photovoltaic system

    Science.gov (United States)

    Song, Jinghui; Yuan, Hui; Xia, Yunfeng; Kan, Weimin; Deng, Xiaowen; Liu, Shi; Liang, Wanlong; Deng, Jianhua

    2018-03-01

    This paper introduces the working principle and system constitution of the linear Fresnel solar lithium bromide absorption refrigeration cycle, and elaborates several typical structures of absorption refrigeration cycle, including single-effect, two-stage cycle and double-effect lithium bromide absorption refrigeration cycle A 1.n effect absorption chiller system based on the best parameters was introduced and applied to a linear Fresnel solar absorption chiller system. Through the field refrigerator performance test, the results show: Based on this heat cycle design and processing 1.n lithium bromide absorption refrigeration power up to 35.2KW, It can meet the theoretical expectations and has good flexibility and reliability, provides guidance for the use of solar thermal energy.

  11. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1997-02-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  12. ARTI refrigerant database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

    1998-08-01

    The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufactures and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on many refrigerants including propane, ammonia, water, carbon dioxide, propylene, ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

  13. ENERGY STAR Certified Vending Machines

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 3.1 ENERGY STAR Program Requirements for Refrigerated Beverage Vending Machines that are...

  14. Modelling of the generation phase of an absorption cooling cycle operating intermittently; Modelisation de la phase generation d'un cycle de refrigeration par absorption solaire a fonctionnement intermittent

    Energy Technology Data Exchange (ETDEWEB)

    Boukhchana, Yasmina; Fellah, Ali; Ben Brahim, Ammar [Unite de Recherche, Thermodynamique Appliquee (99/UR/11-21), Universite de Gabes, Ecole Nationale d' ingenieurs, 6072 Gabes (Tunisia)

    2011-01-15

    No abstract prepared. [French] La modelisation en regime dynamique de la phase generation d'une installation frigorifique a absorption solaire a fonctionnement intermittent utilisant le couple ammoniac/eau a ete elaboree. L'etude basee sur l'intermittence du fonctionnement a permis d'elaborer, a travers les bilans matieres et thermiques, un modele thermodynamique reliant les temperatures, les debits et les fractions massiques dans les differents compartiments. Des journees ensoleillees representatives des quatre saisons de l'annee ont ete considerees. Les variations du taux d'ensoleillement, des temperatures et des concentrations ont ete explorees. Les resultats ont montre, moyennant les hypotheses adoptees en particulier a pression de fonctionnement constante, que la demarche proposee a permis d'avoir une temperature de generation autour de 135 C et une temperature de condensation de 60 C. Ces temperatures sont atteinte par l'adaptation de la convection naturelle a l'air pour le fonctionnement du condenseur. (orig.)

  15. Dual purpose absorption machines in an energy system based on waste incineration; Absorptionsmaskiner foer kyl- och vaermeproduktion i energisystem med avfallsfoerbraenning

    Energy Technology Data Exchange (ETDEWEB)

    Brorsson, Maria [Royal Inst. of Technology, Stockholm (Sweden). Dept. of Chemical Engineering and Technology

    2005-03-01

    The demand for district cooling in Sweden has been increasing during the recent years and is expected to increase even more. The reason for this is for example more frequent use of computers and higher demand for indoor climate control via air conditioning. During the summer there is also a surplus of heat, especially in energy systems that includes waste incineration. This surplus makes it interesting to consider heat-driven cooling as an alternative to satisfy the increasing demand of district cooling. Today many energy systems in Sweden use absorption heat pumps, for production of district heating using waste heat from the combustion units. To this point the absorption heat pumps have not been considered as chillers due to their relatively high investment cost in combination with the short cooling season. However, the surplus of heat during the summer season means that there is access to 'free' driving heat for the absorption chillers. This would be a cheap and environmentally friendly way to produce district cooling. The aim of this study was to examine the opportunities for using absorption machines for production of district heating during wintertime and district cooling during summertime. Factors to be considered were how this change would be made technically and during which months the absorption heat pumps should be used for cold and heat production, respectively. In addition a comparison between absorption cooling and other cooling techniques was made. The study was based on Vattenfall Vaerme Uppsala ABs (VVU) energy system in Uppsala. VVU has recently invested in two new absorption heat pumps that, together with four old ones, are planned to produce district heating as well as district cooling depending on the season. The results of the study are: The technical change between heat and cold production with absorption heat pumps is relatively simple. When used as a chiller the evaporator heat is taken from the district cooling return water, which

  16. Refrigerants and environment

    Science.gov (United States)

    Tsvetkov, O. B.; Laptev, Yu A.

    2017-11-01

    The refrigeration and air-conditioning industries are important sectors of the economy and represents about 15 % of global electricity consumptions. The chlorofluorocarbons also called CFCs are a class of refrigerants containing the halogens chlorine and/or fluorine on a carbon skeleton. Because of their environmental impact the Montreal Protocol was negotiated in 1987 to limit the production of certain CFCs and hydrochlirofluorocarbons (HCFCs) in developed and developing countries. The halogenated refrigerants are depleting the ozone layer also major contribution to the greenhouse effect. To be acceptable as a refrigerant a fluid must satisfy a variety of thermodynamic criteria and should be environment friendly with zero Ozone Depletion Potential and low Global Warming Potential. The perspective of a future phase down of HFCs is considered in this report taking into account a strategy for the phase out of HCFCs and perspective of choosing of various refrigerant followed by safety issues.

  17. Applications of magnetic refrigeration and its assessment. A feasibility study - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kitanovski, A.; Diebold, M.; Vuarnoz, D.; Gonin, C.; Egolf, P. W.

    2008-04-15

    Magnetic refrigeration has the potential to replace conventional refrigeration systems - with often problematic refrigerants - in several niche markets or even some main markets of the refrigeration domain. Based on this insight the Swiss Federal Office of Energy has asked a division of the University of Applied Sciences of Western Switzerland (HEIG-VD) in Yverdon-les-Bains to list all possible refrigeration technologies and to evaluate the potential of magnetic refrigeration for these specific applications. The HEIG-VD researchers have developed a calculation tool to determine the coefficient of performance (COP) value and the exergy efficiency as a function of the magnetic field strength and the rotation frequency of a rotary type of magnetic refrigerator. The considered machine design is based on a patent, which was deposited by these scientists. Based on this work, it is found that especially two applications are very interesting for a closer investigation: the household refrigerator without a freezing compartment and the central chilling unit, which may be of large size. In the domains of refrigeration, where magnetic refrigeration could be successfully applied, the costs for magnetic refrigeration machines would be a little higher than those of the conventional ones. On the other hand the study shows possibilities how the magnetic refrigeration machines could reach higher COP values than those of the corresponding gas compression/expansion machines. Therefore, for magnetic refrigeration one may assume lower costs of operation. For large systems - as e.g. chiller units - it should be studied, if superconducting magnets could be economically applied. (author)

  18. Craft-joule project: air-cooled water LiBr absorption cooling machine of low capacity for air conditioning (ACABMA)

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, A; Castro, J; Perez Segarra, C.D [Universitat Politecnica de Catalunya, Barcelona (Spain); Lucena, M.A [Instituto Nacional de Tecnica Aeroespecial (Spain)] (and others)

    2000-07-01

    The ACABMA (Air-Cooled water-LiBr Absorption cooling Machine of low capacity for Air- conditioning) project is a Craft-Joule Project within the framework of the Non Nuclear Energy Programme Joule III coordinated by the Centre Technologic de Transferencia de Calor (CTTC). The basic objective of this project is the development of a new air-cooled absorption cooling machine for air-conditioning, in the low power sector market. Making use of water-LiBr technology together with the air-cooling feature, it is possible to reach a better relationship between quality (in terms of performance, ecology, etc.) and price of such absorption machines, than the ones existing on the market. Air-cooling instead of water cooling saves installation costs specially in small systems and removes the demand for cooling water (an important aspect in Southern-European countries), thus increasing the possible application range. The main interest for the SME proposers is to take advantage of the increasing cooling demand in Europe, specially in southern countries. Another point of interest for the SME proposers is the development of a cheaper cooling and heating system in terms of energy and installation costs. In this moment the solar cooling systems are approx. 30% more expensive than the conventional ones. A cheaper absorption machine due to the air-cooling feature together with the possibility of energy savings due to low generator temperatures, that allow the absorption machine for solar applications or waste heat, will lead to solar cooling and heating systems more competitive to the conventional ones. In order to achieve the above mentioned goal, the following step are necessary and will be carried out in this project: i)solution of the air-cooling of the water-LiBr machine, the main problem that up to now has not allowed commercialization, ii)reduction of the size of the air-cooled elements of the machine in order to reduce the machine costs, iii)development of an efficient control

  19. Practical methods for measuring refrigerant mass distribution inside refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Guoliang; Ma, Xiaokui; Zhang, Ping; Han, Weizhe [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, No. 800 Dongchuan Road, Shanghai 200240 (China); Kasahara, Shinichi; Yamaguchi, Takahiro [Daikin Air-Conditioning R and D Laboratory, Ltd., 1304 Kanaoka-cho, Sakai, Osaka 591-8511 (Japan)

    2009-03-15

    The purpose of this paper is to present methods for measuring refrigerant mass distribution inside a refrigeration system conveniently and accurately. The quasi on-line measurement method (QOMM) was presented for measuring refrigerant mass inside heat exchangers. Compared with the existing liquid nitrogen method (LNM), QOMM can avoid the refrigerant waste and accelerate the measurement process. For measuring refrigerant mass inside the compressor, QOMM was used together with the oil level observation method. The liquid level method (LLM) was used to measure the refrigerant mass inside the accumulator and the receiver. In order to verify the accuracy of the measurement methods, not only the deviation of the measurement method for refrigerant in single component was analyzed, but also the prediction of the total refrigerant charge in an air conditioner was verified. The results showed that the maximal prediction deviation of the refrigerant charge in the whole refrigeration system is 1.7%. (author)

  20. Low Global Warming Refrigerants For Commercial Refrigeration Systems

    OpenAIRE

    Yana Motta, Samuel F.; Becerra, Elizabet Vera; Spatz, Mark W

    2012-01-01

    New refrigerants with the positive attributes of both high thermal performance and low environmental impact are currently in development. Initial evaluation of these refrigerants in refrigeration systems show good energy efficiency and significant lower global warming impact than current refrigerants. Some of those Low GWP refrigerants are non-azeotropic blends with moderate to high glide; therefore guidance on the use of these blends is needed to achieve the desired good performance and low ...

  1. Potential of the tractor-trailer and container segments as entry markets for a proposed refrigeration technology

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.A.; Davis, L.J.; Garrett, B.A.

    1987-05-01

    The refrigerated trailer and container segments of the transportation industry are evaluated as potential entry markets for a proposed absorption refrigeration technology. To perform this analysis the existing transportation refrigeration industry is characterized; this includes a description of the current refrigeration technology, rating systems, equipment manufacturers, maintenance requirements, and sales trends. This information indicates that the current transportation refrigeration industry is composed of two major competitors, Thermo King and Carrier. In addition, it has low profit potential, some barriers to entry and low growth potential. Data are also presented that characterize the transportation refrigeration consumers, specifically, major groups, market segmentation, consumer decision process, and buying criteria. This consumer information indicates that the majority of refrigerated trailer consumers are private carriers, and that the majority of refrigerated container consumers are shipping companies. Also, these consumers are primarily interested in buying reliable equipment at a low price, and are quite satisfied with existing refrigeration equipment.

  2. REFRIGERANT RECOVERY AND RECYCLING MACHINE: AN INNOVATION

    OpenAIRE

    Nolasco K. Malabago*

    2016-01-01

    The Philippines’ Clean Air Act so provides the control of gas emissions into the atmosphere. To carry out such provisions the implementing arm of the government – Department of Energy and Natural Resources Energy Management Bureau calls for different sectors of the society to join the cause. The University's share of the call in the implementation is to educate the youth and provide ample information on the provisions of the act. One important aspect of the Act is to reclaim the ref...

  3. Thermoacoustic engines and refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    Swift, G.

    1996-12-31

    This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

  4. Public Refrigerated Warehouses

    Data.gov (United States)

    Department of Homeland Security — The International Association of Refrigerated Warehouses (IARW) came into existence in 1891 when a number of conventional warehousemen took on the demands of storing...

  5. Electrochemical Hydrogen Refrigerator

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal is to develop and test a 1 W at 20K Joule‐Thomson cryocooler using an electrochemical compressor. A Joule Thomson refrigerator based on electrochemical...

  6. Refrigeration oils for low GWP refrigerants in various applications

    Science.gov (United States)

    Saito, R.; Sundaresan, S. G.

    2017-08-01

    The practical use of the refrigeration systems is considered as a methods to suppress global warming. The replacement of a refrigerant with a new one that has lower global warming potential (GWP) has been underway for several years. For the application fields of refrigerators, domestic air conditioners, automotive air conditioners and hot water dispensers, the investigation has almost finished. It is still underway for the application fields of commercial air conditioners and chillers, refrigeration facilities for cold storage, etc. And now, the refrigeration system is being applied in various ways to decrease global warming above the generation of electric power with organic Rankine cycle, the binary electric generation with ground source heat pump, and so on. In these situations, various refrigerants are developed and several kinds of suitable refrigeration oils are selected. This paper presents the consideration of suitable refrigeration oil for the various low GWP refrigerants.

  7. Refrigerated display cabinets; Butikskyla

    Energy Technology Data Exchange (ETDEWEB)

    Fahlen, Per

    2000-07-01

    This report summarizes experience from SP research and assignments regarding refrigerated transport and storage of food, mainly in the retail sector. It presents the fundamentals of heat and mass transfer in display cabinets with special focus on indirect systems and secondary refrigerants. Moreover, the report includes a brief account of basic food hygiene and the related regulations. The material has been compiled for educational purposes in the Masters program at Chalmers Technical University.

  8. Refrigeration systems and applications

    CERN Document Server

    Dincer, Ibrahim

    2010-01-01

    Refrigeration Systems and Applications, 2nd edition offers a comprehensive treatise that addresses real-life technical and operational problems, enabling the reader to gain an understanding of the fundamental principles and the practical applications of refrigeration technology. New and unique analysis techniques (including exergy as a potential tool), models, correlations, procedures and applications are covered, and recent developments in the field are included - many of which are taken from the author's own research activities in this area. The book also includes so

  9. High temperature refrigerator

    International Nuclear Information System (INIS)

    Steyert, W.A. Jr.

    1978-01-01

    A high temperature magnetic refrigerator is described which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle the working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot

  10. High temperature refrigerator

    Science.gov (United States)

    Steyert, Jr., William A.

    1978-01-01

    A high temperature magnetic refrigerator which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle said working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot.

  11. Cold machining of high density tungsten and other materials

    Science.gov (United States)

    Ziegelmeier, P.

    1969-01-01

    Cold machining process, which uses a sub-zero refrigerated cutting fluid, is used for machining refractory or reactive metals and alloys. Special carbide tools for turning and drilling these alloys further improve the cutting performance.

  12. Contribution to the realization of a semi-virtual test facility for studies of solar systems. Application to solar cooling by absorption water chillers; Contribution a la realisation d'un laboratoire semi-virtuel pour l'etude de systemes solaires. Application au rafraichissement solaire par machine a absorption

    Energy Technology Data Exchange (ETDEWEB)

    Soler - Blanc, V.

    2003-12-01

    Due to its ecological contribution, solar cooling by absorption water chiller seems to be a good alternative faced with the growth of the buildings air-conditioning market. The CSTB is strongly implied in this field by carrying out a semi-virtual test facility, in order to study the thermal behaviour of these solar cooling systems in dynamic mode. In this semi-virtual laboratory, solar cooling systems are represented partially by virtual components (simulation of buildings, transmitters, solar collectors, climates, etc), the absorption machine remaining a real component. The use of such a test facility has many advantages: amongst other things, it allows to test systems at lower cost, under various configurations, and to deduce optimum conditions for use of the absorption machine in solar cooling.. Beyond the initial tool for the systems assessment, the semi-virtual laboratory can also be a tool of assistance to design installations of solar cooling by absorption machine. Our work is to carry out tests according to a series of day-types. The numerical models created under Matlab/Simulink communicate with the real absorption machine in real time by a control and data acquisition unit: - they get outlets measurements of flows and temperatures from the three hydraulic circuits of the absorption machine (generator, condenser and evaporator); - they set inlets values of flows and temperatures into the three circuits of the absorption machine, according to the tests sequences programmed or the results of the environment's simulation, managed by the PC. These dynamic tests are preceded by a preliminary phase in order to verify the behaviour of the actual part of the test bench. This phase is used to assess the thermal performances of the machine in steady-state mode (COP as announced by the manufacturer), and to obtain a numerical model of the absorption machine in steady-state mode by identification with experimental measurements picked on the test bench up. The

  13. Low Global Warming Potential Refrigerants for Commercial Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sharma, Vishaldeep [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Abdelaziz, Omar [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-06-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Environmental concerns are driving regulations for the heating, ventilating, air-conditioning and refrigeration (HVAC&R) industry towards lower GWP alternatives to HFC refrigerants. Existing lower GWP refrigerant alternatives include hydrocarbons, such as propane (R-290) and isobutane (R-600a), as well as carbon dioxide (R-744), ammonia (R-717), and R-32. In addition, new lower GWP refrigerant alternatives are currently being developed by refrigerant manufacturers, including hydrofluoro-olefin (HFO) and unsaturated hydrochlorofluorocarbon (HCFO) refrigerants. The selection of an appropriate refrigerant for a given refrigeration application should be based on several factors, including the GWP of the refrigerant, the energy consumption of the refrigeration system over its operating lifetime, and leakage of refrigerant over the system lifetime. For example, focusing on energy efficiency alone may overlook the significant environmental impact of refrigerant leakage; while focusing on GWP alone might result in lower efficiency systems that result in higher indirect impact over the equipment lifetime. Thus, the objective of this Collaborative Research and Development Agreement (CRADA) between

  14. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Cain, J.M. [Calm (James M.), Great Falls, VA (United States)

    1993-04-30

    The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

  15. Method for Refrigerators Efficiency Increasing

    Science.gov (United States)

    Suchilin, V. A.; Sumzina, L. V.; Maksimov, A. V.

    2017-11-01

    The article shows that in condenser-type domestic refrigerators the condenser is one of the main parts of the refrigeration system where the refrigerant (freon) compressed by the compressor condenses from the vapor state to the liquid. The condensation process is an exothermic process, i.e., the condensation of steam generates thermal energy. The condenser is heated and, to perform the refrigeration cycle, this heat must be removed from the refrigeration system. Heat removal is carried out in household refrigerators due to the natural circulation of ambient air around the condenser, which must have a significant heat-reflecting area to do this. Although the condenser is most often made of thin tubes that occupy almost the entire rear wall of the refrigerator, the cooling process is not effective enough. A new method for the condenser cooling is proposed which will improve the efficiency of the condenser and household refrigerators as a whole.

  16. ARTI Refrigerant Database

    Energy Technology Data Exchange (ETDEWEB)

    Calm, J.M.

    1992-11-09

    The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

  17. Indirect refrigeration systems with natural refrigerants

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard; Christensen, Kim Gardø; Jensen, Per Henrik

    1998-01-01

    Heat transfer for boiling and condensing carbon dioxide has been investigated.Heat transfer for carbon dioxide evaporating inside pipe has been measured and compared with Shah's correlation. The measured heat transfer coefficient is much higher than the value determined with the correlation.A she......-and-tube heat exchanger with carbon dioxide on the shell side and flow ice inside the tubes has been used to investigate the heat transfer for condensing carbon dioxide.At leats is mentioned results obtained with a frozen food display case using carbone dioxide as refrigerant....

  18. Refrigeration Playbook: Natural Refrigerants; Selecting and Designing Energy-Efficient Commercial Refrigeration Systems That Use Low Global Warming Potential Refrigerants

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Caleb [CTA Architects Engineers, Boise, ID (United States); Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Arthur, Rob [CTA Architects Engineers, Boise, ID (United States); Heath, Richard [CTA Architects Engineers, Boise, ID (United States); Rono, James [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    This report provides guidance for selecting and designing energy efficient commercial refrigeration systems using low global warming potential refrigerants. Refrigeration systems are generally the largest energy end use in a supermarket type building, often accounting for more than half of a building's energy consumption.

  19. Magnetocaloric refrigeration concepts: current state of the art

    DEFF Research Database (Denmark)

    Nielsen, Kaspar Kirstein

    2014-01-01

    of designs and concepts. In this paper key parts constituting a magnetocaloric refrigeration device are reviewed in terms of how they have been implemented in actual machines. Some of the major design choices are then evaluated and, based on numerical modeling tools, recommendations on how to optimize...

  20. Electrocaloric refrigeration: an innovative, emerging, eco-friendly refrigeration technique

    Science.gov (United States)

    Aprea, C.; Greco, A.; Maiorino, A.; Masselli, C.

    2017-01-01

    Nowadays, the refrigeration is responsible of about 15% of the overall energy consumption all over the world. Actually most of the refrigerant fluids working in vapor compression plants (VCPs) are environmentally harmful, since they presents high GWP (Global Warming Potential), which leads to a substantial warming of both earth surface and atmosphere. Electrocaloric refrigeration (ER) is an innovative, emerging refrigeration technique based on solid state refrigerant that shows a great potential. It fits in the context of environment-friendly refrigeration systems, whom are spreading increasingly to replace VCPs. ER is founded on electrocaloric effect that is a physical phenomenon found in materials with dielectric properties, electrocaloric materials. The thermodynamical cycle that best is addressed to the electrocaloric refrigeration is Active Electrocaloric Regeneration cycle (AER) that consists of two adiabatic and two isofield stages. The core of an electrocaloric refrigerator is the regenerator whom operates both as refrigerant and regenerator in an AER cycle. In this paper, we compare the energetic performance of a commercial R134a refrigeration plant to that of an electrocaloric refrigerator working with an AER cycle. The comparison is performed in term of TEWI index (Total Equivalent Warming Impact) that includes both direct and indirect contributions to global warming.

  1. Helium refrigerator for 'SULTAN'

    International Nuclear Information System (INIS)

    Arpagaus, M.; Erlach, H.; Quack, H.

    1984-01-01

    The authors describe the helium refrigerator designed for the SULTAN test facility. SULTAN (Supraleiter-Testanlage) is intended to serve for the developments and testing of high field superconducting magnets. These magnets are needed mainly for future applications in nuclear fusion. (Auth.)

  2. Solar Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  3. Fundamentals of Refrigeration.

    Science.gov (United States)

    Sutliff, Ronald D.; And Others

    This self-study course is designed to familiarize Marine enlisted personnel with the principles of the refrigeration process. The course contains five study units. Each study unit begins with a general objective, which is a statement of what the student should learn from the unit. The study units are divided into numbered work units, each…

  4. Review of secondary loop refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Kai; Eisele, Magnus; Hwang, Yunho; Radermacher, Reinhard [Center for Environmental Energy Engineering, Department of Mechanical Engineering, University of Maryland, College Park, MD 20742 (United States)

    2010-03-15

    Due to the environmental damage caused by HFC refrigerants, there is an increasing universal interest to research environmentally friendly fluids in refrigerants and alternative approaches to the traditional DX refrigeration system. These refrigerants include ammonia, carbon dioxide, hydrocarbon, R152a and HFO1234yf. Major drawbacks of these refrigerants are their potential flammability and safety hazards. One way to overcome this issue is to use the new refrigerants in conjunction with a secondary loop refrigeration system. Additional benefits of the secondary loop refrigeration system are refrigerant charges, leakage reduction, potential maintenance simplification, and low operating cost. This article presents a comprehensive review of the secondary loop refrigeration systems. Furthermore, this review covers the performance and risk assessment of flammable refrigerants, secondary refrigerants and components of the secondary loop refrigeration system within the following applications: commercial refrigeration, residential air conditioning/heat pumping, and mobile air conditioning. (author)

  5. Installation of a small central thermoelectric using biomass and cogeneration with absorption refrigeration system: alternative for small rural isolated communities; Instalacao de uma pequena central termeletrica a biomassa e cogeracao com sistema de refrigeracao por absorcao: alternativa para pequenas comunidades agricolas isoladas

    Energy Technology Data Exchange (ETDEWEB)

    Zukowski Junior, Joel Carlos; Marcon, Rogerio Olavo; Reys, Marcos Alves dos [Centro Universitario Luterano de Palmas (CEULP), TO (Brazil); Cortez, Luis Augusto Barbosa [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Nucleo Interdisciplinar de Planejamento Energetico (NIPE)

    2004-07-01

    The lack of electrical energy in several localities of Brazil results in a slow perspective of in terms of economic growth and scientific and technological development. In order to minimize these problems it is proposed the use of co-generation systems with small thermoelectric plants burning rice rusk (an abundant biomass in certain regions of Brazil, as for example the Tocantins State) as a heat source and to utilize the discharged steam from the turbine to generate cold through an absorption refrigeration system. The work intends to show a possible solution to the problems originated from the absence of electric power in small and isolated rural villages, also problems of processing storage of agricultural residues and to generate cold for several applications. (author)

  6. Absorption heat pumps

    International Nuclear Information System (INIS)

    Formigoni, C.

    1998-01-01

    A brief description of the difference between a compression and an absorption heat pump is made, and the reasons why absorption systems have spread lately are given. Studies and projects recently started in the field of absorption heat pumps, as well as criteria usually followed in project development are described. An outline (performance targets, basic components) of a project on a water/air absorption heat pump, running on natural gas or LPG, is given. The project was developed by the Robur Group as an evolution of a water absorption refrigerator operating with a water/ammonia solution, which has been on the market for a long time and recently innovated. Finally, a list of the main energy and cost advantages deriving from the use of absorption heat pumps is made [it

  7. Crohn's disease and early exposure to domestic refrigeration.

    Science.gov (United States)

    Malekzadeh, Fatemeh; Alberti, Corinne; Nouraei, Mehdi; Vahedi, Homayoon; Zaccaria, Isabelle; Meinzer, Ulrich; Nasseri-Moghaddam, Siavosh; Sotoudehmanesh, Rasoul; Momenzadeh, Sara; Khaleghnejad, Reza; Rashtak, Shahrooz; Olfati, Golrokh; Malekzadeh, Reza; Hugot, Jean-Pierre

    2009-01-01

    Environmental risk factors playing a causative role in Crohn's Disease (CD) remain largely unknown. Recently, it has been suggested that refrigerated food could be involved in disease development. We thus conducted a pilot case control study to explore the association of CD with the exposure to domestic refrigeration in childhood. Using a standard questionnaire we interviewed 199 CD cases and 207 age-matched patients with irritable bowel syndrome (IBS) as controls. Cases and controls were followed by the same gastroenterologists of tertiary referral clinics in Tehran, Iran. The questionnaire focused on the date of the first acquisition of home refrigerator and freezer. Data were analysed by a multivariate logistic model. The current age was in average 34 years in CD cases and the percentage of females in the case and control groups were respectively 48.3% and 63.7%. Patients were exposed earlier than controls to the refrigerator (X2 = 9.9, df = 3, P = 0.04) and refrigerator exposure at birth was found to be a risk factor for CD (OR = 2.08 (95% CI: 1.01-4.29), P = 0.05). Comparable results were obtained looking for the exposure to freezer at home. Finally, among the other recorded items reflecting the hygiene and comfort at home, we also found personal television, car and washing machine associated with CD. This study supports the opinion that CD is associated with exposure to domestic refrigeration, among other household factors, during childhood.

  8. International solar refrigeration system

    International Nuclear Information System (INIS)

    Jilavi, A.; Khalagi Asadi, M.

    2001-01-01

    An intermittent solar refrigeration system using ammonia as refrigerant and water as absorbent, is fabricated and tested in the Center for Renewable Energy Research and Application. In this system, using solar flat plate collectors, ammonia is separated from the water-ammonia solution with quality 60%, during the day and its cooling effect happens during the night time. The system can be used in areas with high solar intensity in Iran. A comparison between the theoretical and experimental results shows that the average amount of coefficient of performance are close (COP the =0.485, COP exp =0.432). This result represents the potent rol accessibility to temperature below 10 d eg C, while the ambient temperature is about 30 d eg C

  9. Superfluid thermodynamic cycle refrigerator

    Science.gov (United States)

    Swift, Gregory W.; Kotsubo, Vincent Y.

    1992-01-01

    A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

  10. Multilayer Thermionic Refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Mahan, G.D.

    1999-08-30

    A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

  11. How the refrigerator changed history

    CERN Document Server

    Bjornlund, Lydia

    2015-01-01

    How the Refrigerator Changed History examines the invention and evolution of the refrigerator and explores how refrigeration has changed the way people eat and live. Features include essential facts, a glossary, selected bibliography, websites, source notes, and an index, plus a timeline and maps, charts, and diagrams. Aligned to Common Core Standards and correlated to state standards. Essential Library is an imprint of Abdo Publishing, a division of ABDO.

  12. Japanese activities in refrigeration technology

    Science.gov (United States)

    Fujita, T.; Ohtsuka, T.; Ishizaki, Y.

    This paper reviews recent activities in refrigeration technology in Japan. The projects described are stimulated by growing industrial needs or form part of large national projects. The JNR project on the MAGLEV train is currently the most powerful activity and it demands knowledge in all the different disciplines of cryogenics in particular on various scales of refrigeration. Research activities are also directed towards the development of Stirling cycle and magnetic refrigerators for applications in a wider area.

  13. Energy optimisation of domestic refrigerators

    DEFF Research Database (Denmark)

    Jakobsen, Arne; Rasmussen, Bjarne D.

    1998-01-01

    This paper describes the main results of a research project with the objective of reducing the energy consumption of domestic refrigerators by increasing the efficiency of the refrigeration system. The improvement of the system efficiency was to be obtained by:1) Introducing continuous operation...... by using a variable speed compressor for controlling the capacity of the refrigeration system.2) Introducing a variable speed fan for enhancing the heat transfer in the evaporator.It was the aim of the project to reduce the energy consumption of a standard refrigerator, available on the market today, by 50 %....

  14. THERMODYNAMIC PROPERTIES OF SELECTED HFC REFRIGERANTS

    Science.gov (United States)

    Hydrofluorocarbon (HFC) refrigerants are possible alternatives to replace ozone-depleting chlorofluorocarbon and hydrochlorofluorocarbon (HCFC) refrigerants. The flammability of a proposed new refrigerant is a major consideration in assessing its utility for a particular applicat...

  15. Fermilab tevatron five refrigerator system tests

    International Nuclear Information System (INIS)

    Rode, C.; Ferry, R.; Leiniger, M.; Makara, J.; Misek, J.; Mizicko, D.; Richied, D.; Theilacker, J.

    1982-01-01

    The Fermilab Tevatron refrigeration system is described with the layout illustrated. The compressor control loops, the refrigerator control loops, and magnet control loops (two per refrigerator) are described and each illustrated. The mobile purifier is described. A five refrigerator test is presented, using two compressor buildings, satellite refrigerator concept test and the test current to the writing. The configuration of the five refrigerator test is diagramed

  16. The Correlation of Coupled Heat and Mass Transfer Experimental Data for Vertical Falling Film Absorption

    Energy Technology Data Exchange (ETDEWEB)

    Keyhani, M; Miller, W A

    1999-11-14

    Absorption chillers are gaining global acceptance as quality comfort cooling systems. These machines are the central chilling plants and the supply for cotnfort cooling for many large commercial buildings. Virtually all absorption chillers use lithium bromide (LiBr) and water as the absorption fluids. Water is the refrigerant. Research has shown LiBr to he one of the best absorption working fluids because it has a high affinity for water, releases water vapor at relatively low temperatures, and has a boiling point much higher than that of water. The heart of the chiller is the absorber, where a process of simultaneous heat and mass transfer occurs as the refrigerant water vapor is absorbed into a falling film of aqueous LiBr. The more water vapor absorbed into the falling film, the larger the chiller's capacity for supporting comfort cooling. Improving the performance of the absorber leads directly to efficiency gains for the chiller. The design of an absorber is very empirical and requires experimental data. Yet design data and correlations are sparse in the open literature. The experimental data available to date have been derived at LiBr concentrations ranging from 0.30 to 0.60 mass fraction. No literature data are readily available for the design operating conditions of 0.62 and 0.64 mass fraction of LiBr and absorber pressures of 0.7 and 1.0 kPa.

  17. Aspects on modeled and the design of a system of refrigeration by absorption attended with solar energy; Aspectos sobre el modelado y diseno de un sistema de refrigeracion por absorcion asistido con energia solar

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Cascales, J. R.; Vera Garcia, F.; Cano Izquierdo, J. M.; Delgado Marin, J. P.; Martinez Sanchez, R.

    2008-07-01

    In this paper, we study the global modelling of an absorption system working with Br Li-H{sub 2}O. It satisfies the air-conditioning necessities of a classroom in an educational centre in Puerto Lumbreras. Murcia. This system utilises a set of solar collector to satisfy the thermal necessities of the vapour generator in the absorption system. For the dynamical simulation of the system we have used the TRNSYS software. The air-conditioned place has been modelled by using a TRNSYS module called PREBID. In this work, special attention is paid to the absorption equipment model developed by using neural networks which has been implemented in TRNSYS. The paper is closed drawing some conclusions. (Author)

  18. Helical thermoelectrics and refrigeration.

    Science.gov (United States)

    Mani, Arjun; Benjamin, Colin

    2018-02-01

    The thermoelectric properties of a three-terminal quantum spin Hall (QSH) sample are examined. The inherent helicity of the QSH sample helps to generate a large charge power efficiently. Along with charge the system can be designed to work as a highly efficient spin heat engine too. The advantage of a helical over a chiral sample is that, while a multiterminal quantum Hall sample can only work as a quantum heat engine due to broken time reversal (TR) symmetry, a multiterminal QSH system can work effectively as both a charge or spin heat engine and as a charge or spin refrigerator as the TR symmetry is preserved.

  19. Cryogenic Optical Refrigeration

    Science.gov (United States)

    2012-03-22

    εj (j = s, c) representing the surface areas and thermal emissivities of the chamber and sample, respectively. Minimization of Pbb requires Advances...refrigeration of GaAs: theoretical study,” Phys. Rev. B 76(24), 245203 (2007). 58. J. B. Khurgin, “ Surface plasmon-assisted laser cooling of solids,” Phys...ions in crystals with the fluorite structure,” Phys. Status Solidi, B Basic Res. 102(1), 11–59 (1980). 121. A. A. Kaminskii, Laser Crystals: Their

  20. Helical thermoelectrics and refrigeration

    Science.gov (United States)

    Mani, Arjun; Benjamin, Colin

    2018-02-01

    The thermoelectric properties of a three-terminal quantum spin Hall (QSH) sample are examined. The inherent helicity of the QSH sample helps to generate a large charge power efficiently. Along with charge the system can be designed to work as a highly efficient spin heat engine too. The advantage of a helical over a chiral sample is that, while a multiterminal quantum Hall sample can only work as a quantum heat engine due to broken time reversal (TR) symmetry, a multiterminal QSH system can work effectively as both a charge or spin heat engine and as a charge or spin refrigerator as the TR symmetry is preserved.

  1. Energy conserving refrigeration device

    Energy Technology Data Exchange (ETDEWEB)

    Vork, W.D.; Lewis, R.D.

    1989-07-04

    This patent describes a gas refrigeration device having a primary generator, a secondary generator, an absorber, pumping means providing pressurized fluid to the primary generator and means for reducing the pressure of the output of the primary generator. The improvement comprises: a fluid powered motor plumbed to the output of the primary generator so as to utilize the energy in the pressured fluid at the generator outlet to run the motor; a primary pump driven by the fluid powered motor; and an auxiliary pump, the pumps being plumbed in parallel to one another, the output of the pumps being connected to the input of the primary generator.

  2. Dynamic design of gas sorption J-T refrigerator

    International Nuclear Information System (INIS)

    Chan, C.K.

    1986-01-01

    A long-life Joule-Thomson refrigerator which is heat powered, involves no sealing, and has few mechanical parts and is desirable for longterm sensor cooling in space. In the gas-sorption J-T refrigerator, cooling is achieved by gas sorption (either adsorption or absorption) processes. Currently, a modular, single-stage refrigerator is being designed and built to be operated at 20 K. The design was analyzed using a dynamic model, which is described here. The model includes the kinetics of the compressors and the heat switches, the heat transfer of the pre-coolers and the heat exchangers, the on/off ratio of the check valves, and the impedance of the J-T valve. The cooling power, the cycle time, and the operating conditions were obtained in terms of the power input, the heat sink temperature, and the J-T impedance

  3. Dynamic design of gas sorption J-T refrigerator

    Science.gov (United States)

    Chan, C. K.

    1986-01-01

    A long-life Joule-Thomson refrigerator which is heat powered, involves no sealing, and has few mechanical parts is desirable for long-term sensor cooling in space. In the gas-sorption J-T refrigerator, cooling is achieved by gas sorption (either adsorption or absorption) processes. Currently, a modular, single-stage refrigerator is being designed and built to be operated at 20 K. The design was analyzed using a dynamic model, which is described here. The model includes the kinetics of the compressors and the heat switches, the heat transfer of the pre-coolers and the heat exchangers, the on/off ratio of the check valves, and the impedance of the J-T valve. The cooling power, the cycle time, and the operating conditions were obtained in terms of the power input, the heat sink temperature, and the J-T impedance.

  4. Dynamic analysis of the CTAR (constant temperature adsorption refrigeration) cycle

    International Nuclear Information System (INIS)

    Hassan, H.Z.; Mohamad, A.A.; Al-Ansary, H.A.; Alyousef, Y.M.

    2014-01-01

    The basic SAR (solar-driven adsorption refrigeration) machine is an intermittent cold production system. Recently, the CO-SAR (continuous operation solar-powered adsorption refrigeration) system is developed. The CO-SAR machine is based on the theoretical CTAR (constant temperature adsorption refrigeration) cycle in which the adsorption process takes place at a constant temperature that equals the ambient temperature. Practically, there should be a temperature gradient between the adsorption bed and the surrounding atmosphere to provide a driving potential for heat transfer. In the present study, the dynamic analysis of the CTAR cycle is developed. This analysis provides a comparison between the theoretical and the dynamic operation of the CTAR cycle. The developed dynamic model is based on the D-A adsorption equilibrium equation and the energy and mass balances in the adsorption reactor. Results obtained from the present work demonstrate that, the idealization of the constant temperature adsorption process in the theoretical CTAR cycle is not far from the real situation and can be approached. Furthermore, enhancing the heat transfer between the adsorption bed and the ambient during the bed pre-cooling process helps accelerating the heat rejection process from the adsorption reactor and therefore approaching the isothermal process. - Highlights: • The dynamic analysis of the CTAR (constant temperature adsorption refrigeration) cycle is developed. • The CTAR theoretical and dynamic cycles are compared. • The dynamic cycle approaches the ideal one by enhancing the bed precooling

  5. Magnetic refrigerator for hydrogen liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, K; Kondo, T [Department of Physics, Kanazawa University, Kakuma-machi, Kanazawa 920-1192 (Japan); Yoshioka, S; Kamiya, K; Numazawa, T [Tsukuba Magnet Laboratory, National Institute for Materials Science, 3-13 Sakura, Tsukuba 305-0003 (Japan)], E-mail: kmatsu@kenroku.kanazawa-u.ac.jp

    2009-02-01

    Magnetic refrigeration which is based on the magnetocaloric effect of solids has the potential to achieve high thermal efficiency for hydrogen liquefaction. We have been developing a magnetic refrigerator for hydrogen liquefaction which cools down hydrogen gas from liquid natural gas temperature and liquefies at 20 K. The magnetic liquefaction system consists of two magnetic refrigerators: Carnot magnetic refrigerator (CMR) and active magnetic regenerator (AMR) device. CMR with Carnot cycle succeeded in liquefying hydrogen at 20K. Above liquefaction temperature, a regenerative refrigeration cycle should be necessary to precool hydrogen gas, because adiabatic temperature change of magnetic material is reduced due to a large lattice specific heat of magnetic materials. We have tested an AMR device as the precooling stage. It was confirmed for the first time that AMR cycle worked around 20 K.

  6. Regulating Power from Supermarket Refrigeration

    DEFF Research Database (Denmark)

    O'Connell, Niamh; Madsen, Henrik; Pinson, Pierre

    2014-01-01

    This paper presents an analysis of the demand response capabilities of a supermarket refrigeration system, with a particular focus on the suitability for participation in the regulating power market. An ARMAX model of a supermarket refrigeration system is identified using experimental data from...... the Danfoss refrigeration test centre. The complexities of modelling demand response are demonstrated through simulation. Simulations are conducted by placing the identified model in a direct-control demand response architecture, with power reference tracking using model predictive control. The energylimited...... nature of demand response from refrigeration is identified as the key consideration when considering participation in the regulating power market. It is demonstrated that by restricting the operating regions of the supermarket refrigeration system, a simple relationship can be found between the available...

  7. Helium dilution refrigeration system

    Science.gov (United States)

    Roach, P.R.; Gray, K.E.

    1988-09-13

    A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

  8. The limits of on-line dilution refrigerators for NO-studies

    International Nuclear Information System (INIS)

    Schouten, J.C.

    1988-01-01

    A description is given of on-line dilution refrigerators for nuclear orientation studies at ultra low temperatures (T < 20 mK). The experimental requirements are compared with the theoretical performance of dilution refrigerators and the latest technical designs. An analysis of existing and working machines shows that the optimum design is mainly limited by detector-sample distance, magnetic field homogeneity and maximum size of detector. (orig.)

  9. THERMODYNAMIC ANALYSIS AND SIMULATION OF A NEW COMBINED POWER AND REFRIGERATION CYCLE USING ARTIFICIAL NEURAL NETWORK

    Directory of Open Access Journals (Sweden)

    Hossein Rezvantalab

    2011-01-01

    Full Text Available In this study, a new combined power and refrigeration cycle is proposed, which combines the Rankine and absorption refrigeration cycles. Using a binary ammonia-water mixture as the working fluid, this combined cycle produces both power and refrigeration output simultaneously by employing only one external heat source. In order to achieve the highest possible exergy efficiency, a secondary turbine is inserted to expand the hot weak solution leaving the boiler. Moreover, an artificial neural network (ANN is used to simulate the thermodynamic properties and the relationship between the input thermodynamic variables on the cycle performance. It is shown that turbine inlet pressure, as well as heat source and refrigeration temperatures have significant effects on the net power output, refrigeration output and exergy efficiency of the combined cycle. In addition, the results of ANN are in excellent agreement with the mathematical simulation and cover a wider range for evaluation of cycle performance.

  10. Parametric analysis and optimization for a combined power and refrigeration cycle

    International Nuclear Information System (INIS)

    Wang Jiangfeng; Dai Yiping; Gao Lin

    2008-01-01

    A combined power and refrigeration cycle is proposed, which combines the Rankine cycle and the absorption refrigeration cycle. This combined cycle uses a binary ammonia-water mixture as the working fluid and produces both power output and refrigeration output simultaneously with only one heat source. A parametric analysis is conducted to evaluate the effects of thermodynamic parameters on the performance of the combined cycle. It is shown that heat source temperature, environment temperature, refrigeration temperature, turbine inlet pressure, turbine inlet temperature, and basic solution ammonia concentration have significant effects on the net power output, refrigeration output and exergy efficiency of the combined cycle. A parameter optimization is achieved by means of genetic algorithm to reach the maximum exergy efficiency. The optimized exergy efficiency is 43.06% under the given condition

  11. Quantum refrigerators and the third law of thermodynamics.

    Science.gov (United States)

    Levy, Amikam; Alicki, Robert; Kosloff, Ronnie

    2012-06-01

    The rate of temperature decrease of a cooled quantum bath is studied as its temperature is reduced to absolute zero. The third law of thermodynamics is then quantified dynamically by evaluating the characteristic exponent ζ of the cooling process dT(t)/dt∼-T^{ζ} when approaching absolute zero, T→0. A continuous model of a quantum refrigerator is employed consisting of a working medium composed either by two coupled harmonic oscillators or two coupled two-level systems. The refrigerator is a nonlinear device merging three currents from three heat baths: a cold bath to be cooled, a hot bath as an entropy sink, and a driving bath which is the source of cooling power. A heat-driven refrigerator (absorption refrigerator) is compared to a power-driven refrigerator. When optimized, both cases lead to the same exponent ζ, showing a lack of dependence on the form of the working medium and the characteristics of the drivers. The characteristic exponent is therefore determined by the properties of the cold reservoir and its interaction with the system. Two generic heat bath models are considered: a bath composed of harmonic oscillators and a bath composed of ideal Bose/Fermi gas. The restrictions on the interaction Hamiltonian imposed by the third law are discussed. In the Appendices, the theory of periodically driven open systems and its implication for thermodynamics are outlined.

  12. Performance of an auto refrigerant cascade refrigerator operating in gas refrigerant supply (GRS) mode with nitrogen-hydrocarbon and argon-hydrocarbon refrigerants

    Science.gov (United States)

    Gurudath Nayak, H.; Venkatarathnam, G.

    2009-07-01

    There is a worldwide interest in the development of auto refrigerant cascade (ARC) refrigerators operating with refrigerant mixtures. Both flammable and non-flammable refrigerant mixtures can be used in these systems. The performance of an ARC system with optimum nitrogen-hydrocarbon and argon-hydrocarbon mixtures between 90 and 160 K is presented in this paper.

  13. 46 CFR 154.1720 - Indirect refrigeration.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Indirect refrigeration. 154.1720 Section 154.1720... § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene oxide, or methyl bromide, must be an indirect refrigeration system that does not use vapor compression. ...

  14. Magnetic Refrigeration and the Magnetocaloric Effect

    DEFF Research Database (Denmark)

    Petersen, Thomas Frank; Pryds, Nini; Smith, Anders

    2006-01-01

    Magnetic refrigeration at room temperature is an emerging technology for refrigeration, which promises low energy consumption and is environmentalle friendly. Magnetic refrigeration is based on the magnetocaloric effect, which manifests itself as a reversibel increase in temperature when magnetic...... material are plased in a magnetic field. This paper introduces and describes magnetic refrigeration cycles and the magnetocaloric effect, and shows how magnetic refrigeration can be an alternative to vapour-compression refrigeration,. A review of the Danish research on magnetic refrigeration at Risø...

  15. Design and dynamic behaviour of a cold storage system combined with a solar powered thermoacoustic refrigerator

    International Nuclear Information System (INIS)

    Perier-Muzet, Maxime; Bedecarrats, Jean-Pierre; Stouffs, Pascal; Castaing-Lasvignottes, Jean

    2014-01-01

    A heat powered thermoacoustic refrigerator consists in a thermoacoustic engine that produces acoustic work utilizing heat, coupled to a thermoacoustic cooler that converts this acoustic energy into cooling effect. These machines have already proved their capability in laboratory or in space refrigeration. Previous studies have also demonstrated the possibility of using concentrated solar energy as thermal energy sources for low power heat driven thermoacoustic refrigerators. As other solar refrigeration systems, even if the cooling demand generally increases with the intensity of the solar radiation, one of the major difficulties is to insure a frigorific power supply when there is no, or low, solar radiation. The aim of this work is to study a kW scale solar thermoacoustic refrigerator capable to reach temperatures of the industrial refrigeration domain. This refrigerator is combined with a latent cold storage in order to guarantee a sufficient cooling capacity to face to refrigeration loads in spite of the production fluctuations. A description of the studied prototype is done and the model developed to describe the transient behaviour of the main components of this machine is introduced. The results obtained with a simulation of one week with real solar radiations are presented and the behaviour and the energetic performances of the entire system are analysed. Finally the impact of the sizing of the cold storage system is discussed. With the best storage design, the system is capable to supply a cooling power of 400 W at a temperature equal or lower than −20 °C with an average Coefficient Of Performance of the solar thermoacoustic refrigerator equal to 21%

  16. Refrigeration plants for the SSCL

    International Nuclear Information System (INIS)

    McAshan, M.; Ganni, V.; Than, R.; Niehaus, T.

    1991-03-01

    The basic requirements and operating features of the collider cryogenic system have already been described in other publications. The general arrangement of the refrigeration plant and its subsystems is presented, and the issue of how to provide redundancy in the cryogenic system is addressed, and some of the basic features of the refrigeration plants are described. The collider cryogenic system design is not final yet, and this report only reflects the direction and current status of the cryogenic system design

  17. 78 FR 28577 - Notification of Proposed Production Activity: Whirlpool Corporation Subzone 8I; (Washing Machines...

    Science.gov (United States)

    2013-05-15

    ... machine parts to the list of approved finished products and would also add imported components to the...; refrigeration parts; dishwashing machine parts; drying machine parts; water inlet valves; AC/DC fan motors; AC... Activity: Whirlpool Corporation Subzone 8I; (Washing Machines): Clyde and Green Springs, Ohio Whirlpool...

  18. Comparison and Analysis of Lithium Bromide-water Absorption Chillers Using Plastic Heat Transfer Tubes and Traditional Lithium Bromide-water Absorption Chillers

    OpenAIRE

    Xue-dong Zhang

    2010-01-01

    There are extensive applications of lithium bromide-water absorption chillers in industry, but the heat exchangers corrosion and refrigerating capacity loss are very difficult to be solved. In this paper, an experiment was conducted by using plastic heat transfer tubes instead of copper tubes. As an example, for a lithium bromide-water absorption chiller of refrigerating capacity of 35kW, the correlative performance of the lithium bromide-water absorption chiller using pl...

  19. Thermoelectric refrigerator having improved temperature stabilization means

    International Nuclear Information System (INIS)

    Falco, C.M.

    1982-01-01

    A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized

  20. REDUCING REFRIGERANT EMISSIONS FROM SUPERMARKET SYSTEMS

    Science.gov (United States)

    Large refrigeration systems are found in several applications including supermarkets, cold storage warehouses, and industrial processes. The sizes of these systems are a contributing factor to their problems of high refrigerant leak rates because of the thousands of connections, ...

  1. Refrigeration system having dual suction port compressor

    Science.gov (United States)

    Wu, Guolian

    2016-01-05

    A cooling system for appliances, air conditioners, and other spaces includes a compressor, and a condenser that receives refrigerant from the compressor. The system also includes an evaporator that receives refrigerant from the condenser. Refrigerant received from the condenser flows through an upstream portion of the evaporator. A first portion of the refrigerant flows to the compressor without passing through a downstream portion of the evaporator, and a second portion of the refrigerant from the upstream portion of the condenser flows through the downstream portion of the evaporator after passing through the upstream portion of the evaporator. The second portion of the refrigerant flows to the compressor after passing through the downstream portion of the evaporator. The refrigeration system may be configured to cool an appliance such as a refrigerator and/or freezer, or it may be utilized in air conditioners for buildings, motor vehicles, or other such spaces.

  2. Load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Aalborg Nielsen, Henrik

    This report presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. The load for refrigeration is the sum of all cabinets in the supermarket, both low and medium temperature cabinets, and spans a period of one year. As input to the forecasting models the ambient temperature observed near the supermarket together with weather forecasts are used. Every hour...... the hourly load for refrigeration for the following 42 hours is forecasted. The forecast models are adaptive linear time-series models which are fitted with a computationally efficient recursive least squares scheme. The dynamic relations between the inputs and the load is modeled by simple transfer...

  3. Towards Less Refrigeration-dependent Home Practices

    OpenAIRE

    Qian, Min

    2011-01-01

    The thesis focuses on the energy intensity in the household food refrigeration, and it seeks to analyze the way refrigeration is perceived by Norwegians in a historical perspective. The practice theory is applied in the study to interpret how individuals, cultural contexts and people’s routinized practices have contributed to the changing household reliance on food refrigeration. The findings show that it is the household demands for energy services rather than the refrigerating technology it...

  4. Solar Refrigerators Store Life-Saving Vaccines

    Science.gov (United States)

    2014-01-01

    Former Johnson Space Center engineer David Bergeron used his experience on the Advanced Refrigeration Technology Team to found SunDanzer Refrigeration Inc., a company specializing in solar-powered refrigerators. The company has created a battery-free unit that provides safe storage for vaccines in rural and remote areas around the world.

  5. 46 CFR 154.702 - Refrigerated carriage.

    Science.gov (United States)

    2010-10-01

    ... Pressure and Temperature Control § 154.702 Refrigerated carriage. (a) Each refrigeration system must: (1) Have enough capacity to maintain the cargo vapor pressure in each cargo tank served by the system below... the purpose of this section, a “refrigeration unit” includes a compressor and its motors and controls...

  6. Refrigeration Cycle Design for Refrigerant Mixtures by Molecular Simulation

    Czech Academy of Sciences Publication Activity Database

    Smith, W.R.; Francová, Magda; Kowalski, M.; Nezbeda, Ivo

    2010-01-01

    Roč. 75, č. 4 (2010), s. 383-391 ISSN 0010-0765 R&D Projects: GA AV ČR IAA400720710 Grant - others:NSERC(CA) OGP1041 Institutional research plan: CEZ:AV0Z40720504 Keywords : refrigerants * molecular simulations * vapor–liquid equilibrium Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 0.853, year: 2010

  7. Energy-optimised mini-refrigerators; Energieoptimierter Minikuehlschrank. Massnahmen zur Optimierung der Energieeffizienz von Minikuehlschraenken

    Energy Technology Data Exchange (ETDEWEB)

    Burri, A.

    2007-10-15

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at measures to be taken to optimise the energy-efficiency of small refrigerators. Such devices are typically to be found in hotel rooms and on boats as well as in caravans and motor homes. The majority of these mini-refrigerators use the absorption principle for cooling. Although less efficient than their compressor-driven counterparts, absorption refrigerators satisfy market requirements and customer wishes with regard to noiseless and maintenance-free operation. The report discusses how optimisation of the absorption principle could lead to energy savings in the long term. The operating principles and energy balances of such refrigerators are discussed and a market overview is presented. Energy consumption of the refrigerators, possible savings and energy costs are discussed. The advantages and disadvantages of various cooling systems are examined as are further possibilities for making savings such as the optimisation of sizing, installation methods, airflow factors and operating temperatures.

  8. IMPACT OF REFRIGERANTS ON ENVIRONMENT AND STUDY OF SOME ALTERNATIVE SUBSTANCES AS REFRIGERANTS

    OpenAIRE

    Vaibhav khurana; Arpan Taneja

    2014-01-01

    In this paper we study that most refrigerants affect the environment and study how to calculate ODP and GWP of the refrigerants. After study the effect of these refrigerants on environment here some new substance which we can use a refrigerants are suggested, which are less harmful to the environment as compared to the other refrigerants. Thereafter study of thermodynamic, chemical and physical properties of the new substance was conducted and compared with the ideal properties of the refr...

  9. A diagnostic methodology for refrigerating systems; Methodologie de diagnostic des installations frigorifiques

    Energy Technology Data Exchange (ETDEWEB)

    Vrinat, G. [Association Francaise du Froid (AFF), 75 - Paris (France)

    1997-12-31

    A diagnostic methodology for refrigerating machines, equipment and plants has been defined and evaluated for EDF, the French national power utility and ADEME, the French Agency for Energy Conservation, in the framework of energy conservation objectives: the diagnostic method should enable to identify malfunctions, assess the cost efficiency of the equipment, identify limiting factors, and consider corrective measures

  10. Finite time thermodynamics of power and refrigeration cycles

    CERN Document Server

    Kaushik, Shubhash C; Kumar, Pramod

    2017-01-01

    This book addresses the concept and applications of Finite Time Thermodynamics to various thermal energy conversion systems including heat engines, heat pumps, and refrigeration and air-conditioning systems. The book is the first of its kind, presenting detailed analytical formulations for the design and optimisation of various power producing and cooling cycles including but not limited to: • Vapour power cycles • Gas power cycles • Vapour compression cycles • Vapour absorption cycles • Rankine cycle coupled refrigeration systems Further, the book addresses the thermoeconomic analysis for the optimisation of thermal cycles, an important field of study in the present age and which is characterised by multi-objective optimization regarding energy, ecology, the environment and economics. Lastly, the book provides the readers with key techniques associated with Finite Time Thermodynamics, allowing them to understand the relevance of irreversibilitie s associated with real processes and the scientific r...

  11. High Efficiency, Low Emission Refrigeration System

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2016-08-01

    Supermarket refrigeration systems account for approximately 50% of supermarket energy use, placing this class of equipment among the highest energy consumers in the commercial building domain. In addition, the commonly used refrigeration system in supermarket applications is the multiplex direct expansion (DX) system, which is prone to refrigerant leaks due to its long lengths of refrigerant piping. This leakage reduces the efficiency of the system and increases the impact of the system on the environment. The high Global Warming Potential (GWP) of the hydrofluorocarbon (HFC) refrigerants commonly used in these systems, coupled with the large refrigerant charge and the high refrigerant leakage rates leads to significant direct emissions of greenhouse gases into the atmosphere. Methods for reducing refrigerant leakage and energy consumption are available, but underutilized. Further work needs to be done to reduce costs of advanced system designs to improve market utilization. In addition, refrigeration system retrofits that result in reduced energy consumption are needed since the majority of applications address retrofits rather than new stores. The retrofit market is also of most concern since it involves large-volume refrigerant systems with high leak rates. Finally, alternative refrigerants for new and retrofit applications are needed to reduce emissions and reduce the impact on the environment. The objective of this Collaborative Research and Development Agreement (CRADA) between the Oak Ridge National Laboratory and Hill Phoenix is to develop a supermarket refrigeration system that reduces greenhouse gas emissions and has 25 to 30 percent lower energy consumption than existing systems. The outcomes of this project will include the design of a low emission, high efficiency commercial refrigeration system suitable for use in current U.S. supermarkets. In addition, a prototype low emission, high efficiency supermarket refrigeration system will be produced for

  12. Magnetic refrigerator for hydrogen liquefaction

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T [National Institute for Materials Science, Tsukuba (Japan); Kamlya, K. [Japan Atomic Energy Agency, Naka (Japan); Utaki, T. [Osaka University, Osaka (Japan); Matsumoto, K. [Kanazawa University, Kanazawa (Japan)

    2013-06-15

    This paper reviews the development status of magnetic refrigeration system for hydrogen liquefaction. There is no doubt that hydrogen is one of most important energy sources in the near future. In particular, liquid hydrogen can be utilized for infrastructure construction consisting of storage and transportation. Liquid hydrogen is in cryogenic temperatures and therefore high efficient liquefaction method must be studied. Magnetic refrigeration which uses the magneto-caloric effect has potential to realize not only the higher liquefaction efficiency > 50 %, but also to be environmentally friendly and cost effective. Our hydrogen magnetic refrigeration system consists of Carnot cycle for liquefaction stage and AMR (active magnetic regenerator) cycle for precooling stages. For the Carnot cycle, we develop the high efficient system > 80 % liquefaction efficiency by using the heat pipe. For the AMR cycle, we studied two kinds of displacer systems, which transferred the working fluid. We confirmed the AMR effect with the cooling temperature span of 12 K for 1.8 T of the magnetic field and 6 second of the cycle. By using the simulation, we estimate the total efficiency of the hydrogen liquefaction plant for 10 kg/day. A FOM of 0.47 is obtained in the magnetic refrigeration system operation temperature between 20 K and 77 K including LN2 work input.

  13. Solar-Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2001-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  14. Solar-Powered Refrigeration System

    Science.gov (United States)

    Ewert, Michael K. (Inventor); Bergeron, David J., III (Inventor)

    2002-01-01

    A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

  15. Magnetic refrigeration using flux compression in superconductors

    International Nuclear Information System (INIS)

    Israelsson, U.E.; Strayer, D.M.; Jackson, H.W.; Petrac, D.

    1990-01-01

    The feasibility of using flux compression in high-temperature superconductors to produce the large time-varying magnetic fields required in a field cycled magnetic refrigerator operating between 20 K and 4 K is presently investigated. This paper describes the refrigerator concept and lists limitations and advantages in comparison with conventional refrigeration techniques. The maximum fields obtainable by flux compression in high-temperature superconductor materials, as presently prepared, are too low to serve in such a refrigerator. However, reports exist of critical current values that are near usable levels for flux pumps in refrigerator applications. 9 refs

  16. Analysis of advanced conceptual designs for single-family-sized absorption chillers. Annual report

    Energy Technology Data Exchange (ETDEWEB)

    1978-09-27

    The objectives of the research reported is to develop and analyze new concepts for absorption cycles to improve the performance or reduce the cost of a 3-ton absorption chiller that can be used with solar collected heat. New refrigerant-absorbent pairs are investigated, as are additives to currently used refrigerant-absorbent pairs. Results are given of a literature search on those topics. An initial screening is reported to check the values of the heats of mixing of candidate refrigerants and adsorbents, and also to screen several candidate absorbents against water as a refrigerant. A modified apparatus and procedures for measurement of refrigerant-absorbent solubilities are described. Pressure-temperature-composition data for the R-22/E-181 pair were measured. Based on theory and the information found in the literature, a set of criteria and guidelines was developed that gives the desirable properties of the refrigerants, absorbents, and pairs. (LEW)

  17. Overall performance of the duplex Stirling refrigerator

    International Nuclear Information System (INIS)

    Erbay, L. Berrin; Ozturk, M. Mete; Doğan, Bahadır

    2017-01-01

    Highlights: • Overall performance coefficient of duplex Stirling refrigerator was investigated. • A definite region for the coefficient of performance of the refrigerator in duplex Stirling is identified. • A definite region for the thermal efficiency of the heat engine in duplex Stirling is identified. • Benchmark values and design bounds of the duplex Stirling refrigerator were obtained. - Abstract: The duplex Stirling refrigerator is an integrated refrigerator consists of Stirling cycle engine and Stirling cycle refrigerator used for cooling. The equality of the work generation of the heat engine to the work consumption of the refrigerator is the primary constraint of the duplex Stirling. The duplex Stirling refrigerator is investigated thermodynamically by considering the effects of constructional and operational parameters which are namely the temperature ratios for heat engine and refrigerator, and the compression ratios for both sides. The primary concern is given to the parametric effects on the overall coefficient of performance of the duplex Stirling refrigerator. The given diagrams provide a design bounds and benchmark results that allows seeing the big picture about the cooling load and heat input relation. Moreover they ease to determine the corresponding work rate to the target cooling load. As regard to the obtained results, a definite region for coefficient of performance of the refrigerator and a definite region for the thermal efficiency of the heat engine of the duplex Stirling are identified.

  18. Application of magnetic refrigeration and its assessment

    International Nuclear Information System (INIS)

    Kitanovski, Andrej; Egolf, Peter W.

    2009-01-01

    Magnetic refrigeration has the potential to replace conventional refrigeration-with often problematic refrigerants-in several niche markets or even some main markets of the refrigeration domain. Based on this insight, for the Swiss Federal Office of Energy a list of almost all existing refrigeration technologies was worked out. Then an evaluation how good magnetic refrigeration applies to each of these technologies was performed. For this purpose a calculation tool to determine the coefficient of performance (COP) and the exergy efficiency as a function of the magnetic field strength and the rotation frequency of a rotary-type magnetic refrigerator was developed. The evaluation clearly shows that some application domains are more ideal for a replacement of conventional refrigerators by their magnetic counterparts than others. In the pre-study, four good examples were chosen for a more comprehensive investigation and working out of more detailed results. In this article, the calculation method is briefly described. COP values and exergy efficiencies of one very suitable technology, namely the magnetic household refrigerator, are presented for different operation conditions. Summarizing, it is stated that magnetic refrigeration is a serious environmentally benign alternative to some conventional cooling, refrigeration and air-conditioning technologies

  19. Environment-friendly refrigeration - Switzerland moves forward

    International Nuclear Information System (INIS)

    Stohler, F.

    2003-01-01

    This article presents an interview with Silvan Schaller, president of the Swiss Refrigeration Society SVK and head of a leading Swiss industrial refrigeration company, on the subject of the implementation of new Swiss materials legislation that regulates the use of various refrigerants. In particular, the co-operation between the Society and the regulatory authorities is stressed. The reasons behind the regulations - the protection of the environment and, in particular, the ozone layer - are discussed as are the efforts required by industry to meet them. Future refrigeration technologies and the choice of refrigerants are examined. Measures that will have to be taken by the companies in the refrigeration sector, such as the additional training of personnel and the monitoring of the disposal of wastes, are examined. For the future, the goal of reducing the energy consumption of refrigeration installations is noted

  20. Magnon-driven quantum dot refrigerators

    International Nuclear Information System (INIS)

    Wang, Yuan; Huang, Chuankun; Liao, Tianjun; Chen, Jincan

    2015-01-01

    Highlights: • A three-terminal quantum dot refrigerator is proposed. • The effects of magnetic field, applied voltage, and polarization are considered. • The region that the system can work as a refrigerator is determined. • Two different magnon-driven quantum dot refrigerators are compared. - Abstract: A new model of refrigerator consisting of a spin-splitting quantum dot coupled with two ferromagnetic reservoirs and a ferromagnetic insulator is proposed. The rate equation is used to calculate the occupation probabilities of the quantum dot. The expressions of the electron and magnon currents are obtained. The region that the system can work in as a refrigerator is determined. The cooling power and coefficient of performance (COP) of the refrigerator are derived. The influences of the magnetic field, applied voltage, and polarization of two leads on the performance are discussed. The performances of two different magnon-driven quantum dot refrigerators are compared.

  1. Experiments on helium refrigerant at high speed of rotation

    International Nuclear Information System (INIS)

    Haseler, L.E.; Ball, A.; Scurlock, R.G.

    1976-01-01

    Electrical machines with superconducting field windings can require helium refrigeration in a rotating system. Heat transfer measurements have been made on helium in a rotating open thermosyphon. Various heater surfaces have been used at the end of a 25 mm tube full of helium at a radial distance of 0.22 mm from the rotation axis for speeds up to 37 Hsub(z), for both boiling heat transfer in subcritical helium, and convective heat transfer in sub and supercritical helium. A larger rotor of 0.44 m radius, to rotate up to 60 Hz, has been constructed to extend the range of the experiments. (author)

  2. When are solar refrigerators less costly than on-grid refrigerators: A simulation modeling study.

    Science.gov (United States)

    Haidari, Leila A; Brown, Shawn T; Wedlock, Patrick; Connor, Diana L; Spiker, Marie; Lee, Bruce Y

    2017-04-19

    Gavi recommends solar refrigerators for vaccine storage in areas with less than eight hours of electricity per day, and WHO guidelines are more conservative. The question remains: Can solar refrigerators provide value where electrical outages are less frequent? Using a HERMES-generated computational model of the Mozambique routine immunization supply chain, we simulated the use of solar versus electric mains-powered refrigerators (hereafter referred to as "electric refrigerators") at different locations in the supply chain under various circumstances. At their current price premium, the annual cost of each solar refrigerator is 132% more than each electric refrigerator at the district level and 241% more at health facilities. Solar refrigerators provided savings over electric refrigerators when one-day electrical outages occurred more than five times per year at either the district level or the health facilities, even when the electric refrigerator holdover time exceeded the duration of the outage. Two-day outages occurring more than three times per year at the district level or more than twice per year at the health facilities also caused solar refrigerators to be cost saving. Lowering the annual cost of a solar refrigerator to 75% more than an electric refrigerator allowed solar refrigerators to be cost saving at either level when one-day outages occurred more than once per year, or when two-day outages occurred more than once per year at the district level or even once per year at the health facilities. Our study supports WHO and Gavi guidelines. In fact, solar refrigerators may provide savings in total cost per dose administered over electrical refrigerators when electrical outages are less frequent. Our study identified the frequency and duration at which electrical outages need to occur for solar refrigerators to provide savings in total cost per dose administered over electric refrigerators at different solar refrigerator prices. Copyright © 2017. Published

  3. Machine tool

    International Nuclear Information System (INIS)

    Kang, Myeong Sun

    1981-01-01

    This book indicates machine tool, which includes cutting process and processing by cutting process, theory of cutting like tool angle and chip molding, cutting tool such as milling cutter and drill, summary and introduction of following machine ; spindle drive and feed drive, pivot and pivot bearing, frame, guide way and table, drilling machine, boring machine, shaper and planer, milling machine, machine tool for precision finishing like lapping machine and super finishing machine gear cutter.

  4. Towards green lubrication in machining

    CERN Document Server

    Liew Yun Hsien, Willey

    2014-01-01

    The book gives an overview of environmental friendly gaseous and vapour, refrigerated compressed gas, solid lubricant, mist lubrication, minimum quantity lubrication (MQL) and vegetable oils that can be used as lubricants and additives in industrial machining applications. This book introduces vegetable oils as viable and good alternative resources because of their environmental friendly, non-toxic and readily biodegradable nature.  The effectiveness of various types of vegetables oils as lubricants and additives in reducing wear and friction is discussed in this book. Engineers and scientist working in the field of lubrication and machining will find this book useful.

  5. improvement to the design of a solid absorption solar refrigerator

    African Journals Online (AJOL)

    user

    condenser was a stagnant evaporative rectangular tank with 0.6753 m free volume, and 60 mm thick walls and 4m of tubing. ... evaporator tubing were of 18 mm i.d x 21mm o.d. All constructions were of steel. Figure .1 shows a cross .... the inner core. The resistance of the heater and the heating time were measured. Q" was.

  6. Dilution Refrigerator for Nuclear Refrigeration and Cryogenic Thermometry Studies

    Science.gov (United States)

    Nakagawa, Hisashi; Hata, Tohru

    2014-07-01

    This study explores the design and construction of an ultra-low temperature facility in order to realize the Provisional low-temperature scale from 0.9 mK to 1 K (PLTS-2000) in Japan, to disseminate its use through calibration services, and to study thermometry at low temperatures below 1 K. To this end, a dilution refrigerator was constructed in-house that has four sintered silver discrete heat exchangers for use as a precooling stage of a copper nuclear demagnetization stage. A melting curve thermometer attached to the mixing chamber flange could be cooled continuously to 4.0 mK using the refrigerator. The dependence of minimum temperatures on circulation rates can be explained by the calculation of Frossati's formula based on a perfect continuous counterflow heat exchanger model, assuming that the Kapitza resistance has a temperature dependence. Residual heat leakage to the mixing chamber was estimated to be around 86 nW. A nuclear demagnetization cryostat with a nuclear stage containing an effective amount of copper (51 mol in a 9 T magnetic field) is under construction, and we will presently start to work toward the realization of the PLTS-2000. In this article, the design and performance of the dilution refrigerator are reported.

  7. Rotational type of a gravitational ejector refrigerator - A system balance of the refrigerant analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kasperski, Jacek [Wroclaw University of Technology, Institute of Power Engineering and Fluid Mechanics, Wybrzeze Wyspianskiego 27, Wroclaw 50-370 (Poland)

    2010-01-15

    The existing ejector systems were analyzed depending on the way in which the refrigerant returns from the condenser to the generator and evaporator. The research focused on gravitational ejector refrigerator in which hydrostatic pressure of the refrigerant allows to equalize pressure differences between heat exchangers located on different levels. Using centrifugal acceleration instead of gravitational allows to decrease significantly the size of a refrigerator. The name roto-gravitational refrigerator was proposed for that kind of refrigerator. One of the problems of small, compact refrigerators is a little amount of refrigerant. Surrounding temperatures when different from typical may cause drying up of the refrigerant in the exchangers and lead to destabilizing the refrigerator's work. A mathematical analysis of thermal and flow processes occurring in the refrigerant has been conducted. A mathematical model of the refrigerant balance and its numerical solution has been proposed. The analysis of the refrigerator accelerating temperature influence on its work parameters has been conducted for exemplary calculations. (author)

  8. CO2 as a refrigerant

    CERN Document Server

    2014-01-01

    A first edition, the IIR guide “CO2 as a Refrigerant” highlights the application of carbon dioxide in supermarkets, industrial freezers, refrigerated transport, and cold stores as well as ice rinks, chillers, air conditioning systems, data centers and heat pumps. This guide is for design and development engineers needing instruction and inspiration as well as non-technical experts seeking background information on a specific topic. Written by Dr A.B. Pearson, a well-known expert in the field who has considerable experience in the use of CO2 as a refrigerant. Main topics: Thermophysical properties of CO2 – Exposure to CO2, safety precautions – CO2 Plant Design – CO2 applications – Future prospects – Standards and regulations – Bibliography.

  9. Load forecasting of supermarket refrigeration

    DEFF Research Database (Denmark)

    Rasmussen, Lisa Buth; Bacher, Peder; Madsen, Henrik

    2016-01-01

    This paper presents a novel study of models for forecasting the electrical load for supermarket refrigeration. The data used for building the models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. Every hour the hourly electrical load for refrigeration is forecasted for the following 42 h. The forecast models are adaptive linear time series models. The model has two regimes; one for opening hours and one for closing hours, this is modeled by a regime switching model and two different...... methods for predicting the regimes are tested. The dynamic relation between the weather and the load is modeled by simple transfer functions and the non-linearities are described using spline functions. The results are thoroughly evaluated and it is shown that the spline functions are suitable...

  10. Stability of split Stirling refrigerators

    International Nuclear Information System (INIS)

    Waele, A T A M de; Liang, W

    2009-01-01

    In many thermal systems spontaneous mechanical oscillations are generated under the influence of large temperature gradients. Well-known examples are Taconis oscillations in liquid-helium cryostats and oscillations in thermoacoustic systems. In split Stirling refrigerators the compressor and the cold finger are connected by a flexible tube. The displacer in the cold head is suspended by a spring. Its motion is pneumatically driven by the pressure oscillations generated by the compressor. In this paper we give the basic dynamic equations of split Stirling refrigerators and investigate the possibility of spontaneous mechanical oscillations if a large temperature gradient develops in the cold finger, e.g. during or after cool down. These oscillations would be superimposed on the pressure oscillations of the compressor and could ruin the cooler performance.

  11. Mountain Plains Learning Experience Guide: Heating, Refrigeration, & Air Conditioning.

    Science.gov (United States)

    Carey, John

    This Heating, Refrigeration, and Air Conditioning course is comprised of eleven individualized units: (1) Refrigeration Tools, Materials, and Refrigerant; (2) Basic Heating and Air Conditioning; (3) Sealed System Repairs; (4) Basic Refrigeration Systems; (5) Compression Systems and Compressors; (6) Refrigeration Controls; (7) Electric Circuit…

  12. Superconducting tunnel-junction refrigerator

    International Nuclear Information System (INIS)

    Melton, R.G.; Paterson, J.L.; Kaplan, S.B.

    1980-01-01

    The dc current through an S 1 -S 2 tunnel junction, with Δ 2 greater than Δ 1 , when biased with eV 1 +Δ 2 , will lower the energy in S 1 . This energy reduction will be shared by the phonons and electrons. This device is shown to be analogous to a thermoelectric refrigerator with an effective Peltier coefficient π* approx. Δ 1 /e. Tunneling calculations yield the cooling power P/sub c/, the electrical power P/sub e/ supplied by the bias supply, and the cooling efficiency eta=P/sub c//P/sub e/. The maximum cooling power is obtained for eV= +- (Δ 2 -Δ 1 ) and t 1 =T 1 /T/sub c/1 approx. 0.9. Estimates are made of the temperature difference T 2 -T 1 achievable in Al-Pb and Sn-Pb junctions with an Al 2 O 3 tunneling barrier. The performance of this device is shown to yield a maximum cooling efficiency eta approx. = Δ 1 /(Δ 2 -Δ 1 ) which can be compared with that available in an ideal Carnot refrigerator of eta=T 1 /(T 2 -T 1 ). The development of a useful tunnel-junction refrigerator requires a tunneling barrier with an effective thermal conductance per unit area several orders of magnitude less than that provided by the A1 2 O 3 barrier in the Al-Pb and Sn-Pb systems

  13. Energy Efficient Commercial Refrigeration with Carbon Dioxide Refrigerant and Scroll Expanders

    Energy Technology Data Exchange (ETDEWEB)

    Dieckmann, John [TIAX LLC, Lexington, MA (United States)

    2013-04-04

    Current supermarket refrigeration systems are built around conventional fluorocarbon refrigerants – HFC-134a and the HFC blends R-507 and R404A, which replaced the CFC refrigerants, R-12 and R-502, respectively, used prior to the Montreal Protocol phase out of ozone depleting substances. While the HFC refrigerants are non-ozone depleting, they are strong greenhouse gases, so there has been continued interest in replacing them, particularly in applications with above average refrigerant leakage. Large supermarket refrigeration systems have proven to be particularly difficult to maintain in a leak-tight condition. Refrigerant charge losses of 15% of total charge per year are the norm, making the global warming impact of refrigerant emissions comparable to that associated with the energy consumption of these systems.

  14. Optimum operating regimes of common paramagnetic refrigerants

    CERN Document Server

    Wikus, P; Figueroa-Feliciano, E

    2011-01-01

    Adiabatic Demagnetization Refrigerators (ADRs) are commonly used in cryogenic laboratories to achieve subkelvin temperatures. ADRs are also the technology of choice for several space borne instruments which make use of cryogenic microcalorimeters or bolometers {[}1-4]. For these applications, refrigerants with high ratios of cooling capacity to volume, or cooling capacity to mass are usually required. In this manuscript, two charts for the simple selection of the most suitable of several common refrigerants (CAA, CMN, CPA, DGG, FAA, GGG, GLF and MAS) are presented. These graphs are valid for single stage cycles. The selection of the refrigerants is uniquely dependent on the starting conditions of the refrigeration cycle (temperature and magnetic field density) and the desired final temperature. Only thermodynamic properties of the refrigerants have been taken into account, and other important factors such as availability and manufacturability have not been considered. (C) 2011 Elsevier Ltd. All rights reserve...

  15. HeREF-2003: Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 Cost per participant: 500.- CHF Language: Bilingual English...

  16. HeREF-2003 : Helium Refrigeration Techniques

    CERN Multimedia

    2003-01-01

    CERN Technical Training 2003: Learning for the LHC ! Theory, Technology, Maintenance and Control of Helium Refrigerators HeREF-2003 is a course in the framework of the 2002 Technical Training Programme, that will provide a complete introduction to Helium refrigeration, with a practical approach to theory, technology, maintenance and control of Helium refrigeration installations. Theoretical aspects and equations will be limited to a minimum. HeREF-2003 targets an audience of technicians and operators of Helium refrigeration plants at CERN, as well as physicists and engineers needing an overview of current Helium refrigeration techniques. HeREF-2003 will address, among other, issues related to component technology, installation maintenance, process control and Helium purity. A commented visit to a couple of CERN Helium refrigeration or liquefaction plants will also take place. • Duration: 7 half days (4 mornings and 3 afternoons), 6-10 October, 2003 • Cost per participant: 500.- CHF ...

  17. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1992-07-01

    Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  18. Not all counterclockwise thermodynamic cycles are refrigerators

    Science.gov (United States)

    Dickerson, R. H.; Mottmann, J.

    2016-06-01

    Clockwise cycles on PV diagrams always represent heat engines. It is therefore tempting to assume that counterclockwise cycles always represent refrigerators. This common assumption is incorrect: most counterclockwise cycles cannot be refrigerators. This surprising result is explored here for quasi-static ideal gas cycles, and the necessary conditions for refrigeration cycles are clarified. Three logically self-consistent criteria can be used to determine if a counterclockwise cycle is a refrigerator. The most fundamental test compares the counterclockwise cycle with a correctly determined corresponding Carnot cycle. Other criteria we employ include a widely accepted description of the functional behavior of refrigerators, and a corollary to the second law that limits a refrigerator's coefficient of performance.

  19. Evaluation of Virtual Refrigerant Mass Flow Sensors

    OpenAIRE

    Kim, Woohyun; Braun, James E.

    2012-01-01

    Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor ma...

  20. Ecological optimization for generalized irreversible Carnot refrigerators

    Science.gov (United States)

    Chen, Lingen; Xiaoqin, Zhu; Sun, Fengrui; Wu, Chih

    2005-01-01

    The optimal ecological performance of a Newton's law generalized irreversible Carnot refrigerator with the losses of heat resistance, heat leakage and internal irreversibility is derived by taking an ecological optimization criterion as the objective, which consists of maximizing a function representing the best compromise between the exergy output rate and exergy loss rate (entropy production rate) of the refrigerator. Numerical examples are given to show the effects of heat leakage and internal irreversibility on the optimal performance of generalized irreversible refrigerators.

  1. Adsorption refrigeration technology theory and application

    CERN Document Server

    Wang, Ruzhu; Wu, Jingyi

    2014-01-01

    Gives readers a detailed understanding of adsorption refrigeration technology, with a focus on practical applications and environmental concerns Systematically covering the technology of adsorption refrigeration, this book provides readers with a technical understanding of the topic as well as detailed information on the state-of-the-art from leading researchers in the field. Introducing readers to background on the development of adsorption refrigeration, the authors also cover the development of adsorbents, various thermodynamic theories, the design of adsorption systems and adsorption refri

  2. Continuously operating dilution refrigerator with adsorption pumps

    International Nuclear Information System (INIS)

    Majdanov, V.A.; Mikhin, N.P.; Omelaenko, N.F.; Rudavskij, Eh.Ya.; Rybalko, A.S.; Chagovets, V.K.; Mikheev, V.A.

    1994-01-01

    The main parts and performance of two versions of the continuously operating dilution refrigerator with an adsorption pumping system dedicated to physical investigations at ultralow temperatures are described. Compared to conventional dilution refrigerators these versions are more compact, economic and more vibration proof. This type of dilution refrigerator allows a single shot operation to be realized. The minimum temperature reached in a single continuous heat exchanger refrigerator is 18 mK for a continuous operation and 5 - 8 mK for a single shot are. On addition of four discrete heat exchangers, the minimum temperature for continuous operation reduces down to 8 mK

  3. Birth after 12 hours of oocyte refrigeration.

    Science.gov (United States)

    Coban, Onder; Hacifazlioglu, Oguzhan; Ciray, H Nadir; Ulug, Ulun; Tekin, H Ibrahim; Bahceci, Mustafa

    2010-12-01

    To assess cycle outcome after oocyte refrigeration. Case report. Private IVF center. One couple in a donor oocyte program. Intracytoplasmic sperm injection and blastocyst culture after refrigeration of oocytes for 12 hours. Birth. Fourteen two-pronuclei zygotes from 17 metaphase II refrigerated oocytes resulted in transfer of two blastocysts at day 5 and cryopreservation of six excess embryos at day 6. The patient delivered one healthy male baby after 38 weeks' gestation. The successful outcome of oocyte refrigeration indicates that this protocol could be useful in circumstances in which a delay in obtaining spermatozoa arises. Copyright © 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  4. 10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.

    Science.gov (United States)

    2010-01-01

    ... ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Refrigerators...-freezer means refrigeration equipment that— (1) Is not a consumer product (as defined in § 430.2 of part... in cross-section. Holding temperature application means a use of commercial refrigeration equipment...

  5. U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, Jeffery B.; Young, Scott J.; Yang, Hung-Chia; Long, Timothy; Beraki, Bereket; Price, Sarah K.; Pratt, Stacy; Willem, Henry; Desroches, Louis-Benoit

    2013-11-14

    Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated

  6. U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys

    Energy Technology Data Exchange (ETDEWEB)

    Greenblatt, Jeffery B. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Young, Scott J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Yang, Hung-Chia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Long, Timothy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Beraki, Bereket [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Sarah K. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Pratt, Stacy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Willem, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Desroches, Louis-Benoit [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,820 clean survey responses were obtained from four distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 2.9(–2.5,+4.5) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated

  7. ALTERNATIVE TECHNOLOGIES FOR REFRIGERATION AND AIR-CONDITIONING APPLICATIONS

    Science.gov (United States)

    The report gives results of an assessment of refrigeration technologies that are alternatives to vapor compression refrigeration for use in five application categories: domestic air conditioning, commercial air conditioning, mobile air conditioning, domestic refrigeration, and co...

  8. Thermoeconomic model of a commercial transcritical booster refrigeration system

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Elmegaard, Brian

    2011-01-01

    For cooling applications in supermarkets, booster refrigeration systems operating in both transcritical and subcritical conditions are increasingly used. A thermodynamic model of a transcritical booster refrigeration plant is tailored to match the new generation of commercial refrigeration plants...

  9. Magnetic refrigeration at room temperature - from magnetocaloric materials to a prototype

    DEFF Research Database (Denmark)

    Kuhn, Luise Theil; Pryds, Nini; Bahl, Christian Robert Haffenden

    2011-01-01

    materials, their shaping and graded composition for technological use. Modelling the performance of a permanent magnet with optimum use of the flux and relatively low weight, and designing and constructing a prototype continuous magnetic refrigeration device have also been major tasks in the project......Based on the magnetocaloric effect, magnetic refrigeration at room temperature has for the past decade been a promising, environmentally friendly new energy technology predicted to have a significantly higher efficiency than the present conventional methods. However, so far only a few prototype...... refrigeration machines have been presented worldwide and there are still many scientific and technological challenges to be overcome. We report here on the MagCool project, which spans all the way from basic materials studies to the construction of a prototype. Emphasis has been on ceramic magnetocaloric...

  10. Prediction of performance of a jet cooling system operating with pure refrigerants or non-azeotropic mixtures. Influence de la nature des fluides, purs ou en melanges non-azeotropiques, sur les performances d'une machine de climatisation a ejecto-compresseur

    Energy Technology Data Exchange (ETDEWEB)

    Dorantes, R.; Lallemand, A. (Centre National de la Recherche Scientifique (CNRS), 69 Villeurbanne (France). Centre de Thermique)

    1995-01-01

    This paper investigates a simple model of an ejector-compression refrigeration cycle and its applications to air conditioning. The efficiency using either classical refrigerants (R11, R22, R114), other pure refrigerants (R123, R133a, R134a, R141b, R142b, R152a, RC318) or non-azeotropic mixtures is presented. The results suggest that, for different temperatures of the heat source and the heat sink, the entrainment ratio and the system efficiency depend mainly on the fluid type and the mixture composition. An exergetic analysis shows that the major part of the exergy destruction takes place in the ejector, but that the boiler and condenser exergetic losses are significant. (author)

  11. Review of photovoltaic: powered refrigeration for vaccines for developing countries

    Energy Technology Data Exchange (ETDEWEB)

    Field, R.L. (Texas A and M Univ., College Station); Carrasco, P.; de Quadros, C.A.

    1982-01-01

    The application of photovoltaic systems in immunization programs throughout the world is currently being evaluated, with the promise that photovoltaic systems may permit the extension of vaccine delivery systems by using alternative technologies in those areas where conventional forms of energy have yet to be introduced or are too costly. The cold chain is a system whose elements of logistics, equipment, and methodology are linked together to deliver vaccines in an efficient manner at temperatures between +4/sup 0/C to +8/sup 0/C. Vaccines are delicate substances and to keep them potent they must be kept cold from the time they are manufactured to the time of their administration. The cooling system of the vaccine refrigerator may be either of the conventional compression type or absorption type. The use of a direct current thermoelectric cooling system is also being considered. Either the compression or thermoelectric types may be PV powered, and there are incidental electricity needs with the kerosene powered absorption type. A small 10l size refrigerator should be capable of producing 1l of ice in the (8 hours of) night (in +32/sup 0/C design ambient) and must maintain temperature of +4 to +8/sup 0/C during the day (in +43/sup 0/C ambient). It is desirable that a 40l size produce 4l of ice per 24 h in a night-time ambient of +32/sup 0/C. with a COP (coefficient of performance) of 1.0, photocell net area of 1.3m/sup 2/ is needed for the designed compression of absorption type, and an area of 14.6m/sup 2/ is needed for the thermoelectric refrigerator of this size. An 80l size must be capable of producing 1-2l of ice per day (8l desirable). Costs are estimated at $800 for the 10l size, $1675 for 40l size and $3410 for 80l size, including photocells, batteries and refrigerator.

  12. Prediction of Dangerous Time in Case Hydrocarbon Refrigerant Leaks into Household Refrigerator Cabinet

    Science.gov (United States)

    Meguro, Takatoshi; Kaji, Nobufuji; Miyake, Kunihiro

    Hydrocarbon refrigerators are now on sale in European countries. However, hydrocarbons are flammable. A common claim is that concentration of hydrocarbon in the refrigerator could exceed the lower explosive limit by a sudden leak and then a spark ignites a flame causing overpressure. There is the need of the studies on potential risks originated from the use of flammable refrigerants. Thus, the flow rate of the fresh air into the refrigerator cabinet has been defined experimentally, and the spatial average concentration in the refrigerator cabinet has been analyzed theoretically to predict the dangerous time in excess of the lower explosive limit.

  13. Thermal links for the implementation of an optical refrigerator

    Energy Technology Data Exchange (ETDEWEB)

    Epsteiin, Richard I [Los Alamos National Laboratory; Greenfield, Scott R [Los Alamos National Laboratory; Parker, John [HARVEY MUDD COLLEGE; Mar, David [HARVEY MUDD GOLLEGE; Von Der Porten, Steven [HARVEY MUDD COLLEGE; Hankinson, John [HARVEY MUDD COLLEGE; Byram, Kevin [HARVEY MUDD COLLEGE; Lee, Chris [HARVEY MUDD COLLEGE; Mayeda, Kai [HARVEY MUDD COLLEGE; Haskell, Richard [HARVEY MUDD COLLEGE; Yang, Qimin [HARVEY MUDD COLLEGE

    2008-01-01

    Optical refrigeration has been demonstrated by several groups of researchers, but the cooling elements have not been thermally linked to realistic heat loads in ways that achieve the desired temperatures. The ideal thermal link will have minimal surface area, provide complete optical isolation for the load, and possess high thermal conductivity. We have designed thermal links that minimize the absorption of fluoresced photons by the heat load using multiple mirrors and geometric shapes including a hemisphere, a kinked waveguide, and a tapered waveguide. While total link performance is dependent on additional factors, we have observed net transmission of photons with the tapered link as low as 0.04%. Our optical tests have been performed with a surrogate source that operates at 625 nm and mimics the angular distribution of light emitted from the cooling element of the Los Alamos solid state optical refrigerator. We have confirmed the optical performance of our various link geometries with computer simulations using CODE V optical modeling software. In addition we have used the thermal modeling tool in COMSOL MULTIPHYSICS to investigate other heating factors that affect the thermal performance of the optical refrigerator. Assuming an ideal cooling element and a nonabsorptive dielectric trapping mirror, the three dominant heating factors are (1) absorption of fluoresced photons transmitted through the thermal link, (2) blackbody radiation from the surrounding environment, and (3) conductive heat transfer through mechanical supports. Modeling results show that a 1 cm{sup 3} load can be chilled to 107 K with a 100 W pump laser. We have used the simulated steady-state cooling temperatures of the heat load to compare link designs and system configurations.

  14. Refrigeration and air-conditioning

    CERN Document Server

    Hundy, G H; Welch, T C

    2008-01-01

    Now in its fourth edition, this respected text delivers a comprehensive introduction to the principles and practice of refrigeration. Clear and straightforward, it is designed for students (NVQ/vocational level) and professional HVAC engineers, including those on short or CPD courses. Inexperienced readers are provided with a comprehensive introduction to the fundamentals of the technology. With its concise style yet broad sweep the book covers most of the applications professionals will encounter, enabling them to understand, specify, commission, use and maintain these systems. Many readers w

  15. TRANSPORT PROPERTIES FOR REFRIGERANT MIXTURES

    Directory of Open Access Journals (Sweden)

    V. Geller

    2014-06-01

    Full Text Available A set of models to predict viscosity and thermal conductivity of refrigerant mixtures is developed. A general model for viscosity and thermal conductivity use the three contributions sum form (the dilute-gas terms, the residual terms, and the liquid terms. The corresponding states model is recommended to predict the dense gas transport properties over a range of reduced density from 0 to 2. It is shown that the RHS model provides the most reliable results for the saturated-liquid and the compressed-liquid transport properties over a range of given temperatures from 0,5 to 0,95.

  16. A miniaturized plastic dilution refrigerator

    International Nuclear Information System (INIS)

    Bindilatti, V.; Oliveira, N.F.Jr.; Martin, R.V.; Frossati, G.

    1996-01-01

    We have built and tested a miniaturized dilution refrigerator, completely contained (still, heat exchanger and mixing chamber) inside a plastic (PVC) tube of 10 mm diameter and 170 mm length. With a 25 cm 2 CuNi heat exchanger, it reached temperatures below 50 mK, for circulation rates below 70 μmol/s. The cooling power at 100 mK and 63 μmol/s was 45 μW. The experimental space could accommodate samples up to 6 mm in diameter. (author)

  17. Numerical model to optimize the refrigerant charge for maximum refrigeration capacity

    Directory of Open Access Journals (Sweden)

    Wainaina Patrick M.

    2013-01-01

    Full Text Available Refrigeration systems require optimal amount of refrigerant for maximum system performance. Undercharged or overcharged systems experience reduced efficiency and accessories deterioration. Optimal amount of refrigerant to be charged in a refrigeration system depends on the physical and thermal dynamic properties of the evaporator and the refrigerant. This paper presents formulation of a numerical model that can be used in determination of optimal amount of refrigerant charged in a system for maximum cooling rate as hence maximum system performance. Rayleigh’s method of dimensional analysis was used obtain the relationship between the maximum cooling rates of direct expansion evaporators as a function of thermodynamic properties of refrigerant R-134a, Different sizes of evaporator were fitted in the refrigeration system and charged with systematically varying amount of refrigerant until a maximum cooling rate was determined. The variation of pressures and temperatures both at the inlet and exit of the evaporator were observed and analyzed. The cooling rate of the numerical model formulated was compared with the cooling rate the actual physical refrigeration system. A t-test of 95% confidence interval indicated no significance difference between the numerical model, and the physical refrigeration system.

  18. Refrigerant capacity of europium sulfide and its use in magnetic refrigeration

    International Nuclear Information System (INIS)

    Potter, W.H.; Wood, M.E.

    1986-01-01

    The authors recently showed that the refrigerant capacity - the product of entropy absorbed by a refrigerant at the cycle cold temperature and the cycle temperature span, ΔS/sub c/ΔT - provides a very useful measure of refrigeration. Analyzing ΔS/sub c/ΔT as a function of refrigerant and cycle parameters provides a general approach to refrigeration optimization. In this paper the authors apply this approach to magnetic refrigeration using EuS, a ferromagnet with T/sub o/ = 16.5 K, as the refrigerant in a regenerative cycle. They examine the effects of irreversibilities and find that even for values of irreversible entropy production, S/sub IRR/, as large as ΔS/sub c/, optimized values of ΔT remain large for all applied fields, while the optimum values of T/sub c/ decrease slightly as S/sub IRR/ increases

  19. Eco-Friendly Alternative Refrigeration Systems

    Indian Academy of Sciences (India)

    with the aid of an external energy source is called a refrigerator and use of natural refrigeration in day to day life is as ... investigations have shown that human- made chemicals are responsible for the observed depletion of ozone layer. Increase of Earth's surface temperature by a few degrees is expected to produce many.

  20. 21 CFR 1250.34 - Refrigeration equipment.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Refrigeration equipment. 1250.34 Section 1250.34 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... SANITATION Food Service Sanitation on Land and Air Conveyances, and Vessels § 1250.34 Refrigeration equipment...

  1. Refrigeration and thermometry below one Kelvin

    International Nuclear Information System (INIS)

    Betts, D.S.

    1976-01-01

    The subject is dealt with in chapters, entitled; fundamental principles of refrigeration; pumped helium evaporation cryostats; helium-3 dilution refrigeration; Pomeranchuk cooling by adiabatic solidification of helium-3; magnetic cooling with electron paramagnetic salts; nuclear demagnetisation; thermometry using helium; magnetic thermometry; thermometry using electrical properties; noise thermometry; Moessbauer effect thermometry; nuclear orientation thermometry. (U.K.)

  2. Commercial Refrigeration Technology. Florida Vocational Program Guide.

    Science.gov (United States)

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    The program guide for commercial refrigeration technology courses in Florida identifies primary considerations for the organization, operation, and evaluation of a vocational education program. Following an occupational description for the job title for refrigeration mechanic, and its Dictionary of Occupational Titles code, are six sections…

  3. Energy efficient control of a refrigeration plant

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Larsen, Lars F. S.

    2009-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The new idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...... and the methods are evaluated with respect to energy efficiency....

  4. Evaluation of Refrigerating and Air Conditioning Devices in Energy Cascade Systems under the Restriction of Carbon Dioxide Emissions

    Science.gov (United States)

    Shimazaki, Yoichi; Akisawa, Atsushi; Kashiwagi, Takao

    It is necessary to introduce energy cascade systems into the industrial sector in Japan to reduce carbon dioxide emissions. The aim of this study is to evaluate the refrigerating and air conditioning devices in cases of introducing both energy cascade systems and thermal recycling systems in industries located around urban areas. The authors have developed an energy cascade model based on linear programming so as to minimize the total system costs with carbon taxes. Five cases are investigated. Limitation of carbon dioxide emissions results in the enhancement of heat cascading, where high temperature heat is supplied for process heating while low temperature one is shifted to refrigeration. It was found that increasing the amount of garbage combustor waste heat can reduce electric power for the turbo refrigerator by promoting waste heat driven ammonia absorption refrigerator.

  5. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1992-10-01

    Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  6. Compatibility of refrigerants and lubricants with elastomers

    Energy Technology Data Exchange (ETDEWEB)

    Hamed, G.R.; Seiple, R.H.

    1993-01-01

    The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

  7. Sorption compressor/mechanical expander hybrid refrigeration

    Science.gov (United States)

    Jones, J. A.; Britcliffe, M.

    1987-01-01

    Experience with Deep Space Network (DSN) ground-based cryogenic refrigerators has proved the reliability of the basic two-stage Gifford-McMahon helium refrigerator. A very long life cryogenic refrigeration system appears possible by combining this expansion system or a turbo expansion system with a hydride sorption compressor in place of the usual motor driven piston compressor. To test the feasibility of this system, a commercial Gifford-McMahon refrigerator was tested using hydrogen gas as the working fluid. Although no attempt was made to optimize the system for hydrogen operation, the refrigerator developed 1.3 W at 30 K and 6.6 W at 60 K. The results of the test and of theoretical performances of the hybrid compressor coupled to these expansion systems are presented.

  8. Operating Manual of Helium Refrigerator (Rev. 2)

    Energy Technology Data Exchange (ETDEWEB)

    Song, K.M.; Son, S.H.; Kim, K.S.; Lee, S.K.; Kim, M.S. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    A helium refrigerator was installed as a supplier of 20K cold helium to the cryogenic distillation system of WTRF pilot plant. The operating procedures of the helium refrigerator, helium compressor and auxiliary apparatus are described for the safety and efficient operation in this manual. The function of the helium refrigerator is to remove the impurities from the compressed helium of about 250psig, to cool down the helium from ambient temperature to 20K through the heat exchanger and expansion engine and to transfer the cold helium to the cryogenic distillation system. For the smoothly operation of helium refrigerator, the preparation, the start-up, the cool-down and the shut-down of the helium refrigerator are described in this operating manual. (author). 3 refs., 14 tabs.

  9. Novel materials for laser refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Hehlen, Markus P [Los Alamos National Laboratory

    2009-01-01

    The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

  10. Manufacturing A Refrigerator with Heat Recovery Unit

    Directory of Open Access Journals (Sweden)

    Mustafa Mohammed Kadhim

    2018-02-01

    Full Text Available This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials. It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing of a refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a which comes out of the compressor would be removed  inside this cabinet and this insist to condensate the refrigerant (cooling fluid with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet. To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy  can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in the coeffecient of performance in state of operation the

  11. Analysis of a solar powered absorption system

    International Nuclear Information System (INIS)

    Said, S.A.M.; El-Shaarawi, M.A.I.; Siddiqui, M.U.

    2015-01-01

    Highlights: • Conventional absorption system modified to increase COP. • Results indicated increase of 10% in COP due to dephlegmator heat recovery. • Results indicated increase of 8% in COP due to refrigerant storage unit. • Results indicated increase of 18% in COP due to combined effect of modifications. • Simulation results indicated a very good agreement with the measured results. - Abstract: Today, fossil fuel is the primary extensively used source of energy. However, its negative impact on the environment have forced the energy research continuity to seriously consider renewable sources of energy. Solar energy, in particular, has been the main focus in this regard because it is a source of clean energy and naturally available. This study presents the design and analysis of a solar powered absorption refrigeration system modified to increase its coefficient of performance (COP). The modifications include recovering of waste heat from a dephlegmator and utilization of a refrigerant storage unit. The simulation results indicate an increase of 10% in the COP of the conventional design using dephlegmator heat recovery and an increase of 8% in the COP of the conventional design due to the use of a refrigerant storage. The analysis for the combined effect of modifications indicates an increase of 18% in the COP compared to conventional design. Calculated values of coefficient of performance indicate a very good agreement with the ones obtained based on measurement

  12. A review of carbon dioxide as a refrigerant in refrigeration technology

    Directory of Open Access Journals (Sweden)

    Paul Maina

    2015-09-01

    Full Text Available Tough environmental laws and stringent government policies have revolutionised the refrigeration sector, especially concerning the cycle fluid known as the refrigerant. It has been observed that only natural refrigerants are environmentally benign. When other refrigerant qualities are considered, especially those relating to toxicity and flammability, carbon dioxide emerges as the best among the natural refrigerants. However, carbon dioxide based refrigerants are not without drawbacks. Even though the use of R744 a carbon dioxide based refrigerant gas has solved the direct effect of emissions on the environment, studies to investigate the indirect effects of these systems are needed. Improvement in existing technical solutions and the formulation of additional solutions to existing R744 refrigeration problems is paramount if this technology is to be accepted by all, especially in areas with warm climates. National policies geared to green technologies are important to clear the way and provide support for these technologies. It is clear that carbon dioxide is one of the best refrigerants and as environmental regulations become more intense, it will be the ultimate refrigerant of the future.

  13. Energy performance of supermarket refrigeration and air conditioning integrated systems working with natural refrigerants

    International Nuclear Information System (INIS)

    Cecchinato, Luca; Corradi, Marco; Minetto, Silvia

    2012-01-01

    The current trends in commercial refrigeration aim at reducing the synthetic refrigerant charge, either by minimising the internal volume of the circuit or by utilising natural refrigerants, and at energy saving. The energy efficiency of supermarkets can be improved by optimising components design, recovering thermal and refrigerating energy, adopting innovative technology solutions, integrating the HVAC system with medium temperature and low temperature refrigeration plants and, finally, reducing thermal loads on refrigerated cases. This study aims at investigating the performance of different lay-out and technological solutions where only natural refrigerants are used and at finding the potential for improving energy efficiency over the traditional systems in different climates. In the analysis, chillers and heat pumps working with ammonia or propane, medium temperature systems working with ammonia or propane and carbon dioxide as heat transfer fluid or with carbon dioxide as the refrigerant and low temperature systems working with carbon dioxide are considered and benchmarked with a state-of-the-art HFCs based plant. The most efficient investigated solution enables an annual energy saving higher than 15% with respect to the baseline solution for all the considered climates. - Highlights: ► Different natural refrigerants supermarket HVAC and R integrated systems are analysed. ► Some of the proposed solutions offer a significant benefit over the baseline one. ► Up to 18.7% energy saving is achieved in the considered climates. ► The refrigeration unit condensation by the AC chiller offers the poorest results.

  14. Ultrasonic absorption

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews studies of ultrasonic absorption in liquid alkali metals. The experimental methods to measure the absorption coefficients are briefly described. Experimental results reported for the liquid metals: sodium, potassium, rubidium and caesium, at medium temperatures, are presented, as well as data for liquid alloys. Absorption losses due to the presence of an external magnetic field, and the effects of viscosity on the absorption in metals, are both discussed. (U.K.)

  15. Instability of refrigeration system - A review

    International Nuclear Information System (INIS)

    Liang Nan; Shao Shuangquan; Xu Hongbo; Tian Changqing

    2010-01-01

    It is essential to ensure the stability for the normal operation of refrigeration systems. This paper reviews the researches on the theory and solutions of the instability of refrigeration systems. The instability of refrigeration systems includes two aspects: the two-phase flow instability in refrigeration system, the instability on refrigeration system control characteristics. As an inherent characteristic of two-phase evaporating flow, several separate explanations for the formation of oscillation of mixture-vapor transition point in the evaporation process by different scholars had been given but there is no general explanation till now. The investigation of instability on refrigeration system control characteristics focused on both static and dynamic researches. The minimum stable signal line theory, as a very important finding for the static instability of the evaporator and thermal expansion valve control loop, presented the different result to other researches. Dynamic researches on simulation and frequency-domain analysis provided various means for forecast and validation with considerable precision while their application range was still confined. With the development of variable capacity compressor and electronic expansion valve, further researches should be carried out to analyze the instability of the variable capacity refrigeration system with considering the influence of parameter coupling and control algorithm.

  16. 46 CFR 111.79-15 - Receptacles for refrigerated containers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Receptacles for refrigerated containers. 111.79-15... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Receptacles § 111.79-15 Receptacles for refrigerated containers. Receptacles for refrigerated containers must meet one of the following: (a) Each receptacle for refrigerated...

  17. 46 CFR 58.20-15 - Installation of refrigerating machinery.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Installation of refrigerating machinery. 58.20-15 Section 58.20-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Refrigeration Machinery § 58.20-15 Installation of refrigerating machinery. (a) Where refrigerating...

  18. Experimental Study on a Stirling Cycle Machine of 100W Design Capacity

    Science.gov (United States)

    Otaka, Toshio; Kodama, Itaru; Ota, Masahiro

    Environmental concerns are causing commonly used chlorofluorocarbon (CFC) refrigerants to be phased out of production. The less ozone-depleting HCFC's are regulating. The green house effecting HFC's are also likely to be regulated and banned in the next period. Accordingly, attention is drawn to the Stirling refrigerator, which is a perfect Freon free refrigerator. Moreover, The Stirling cycle has the highest theoretical cycle efficiency corresponding to the value of the Carnot cycle among the proposed thermodynamic cycles. The green house effect by carbon dioxide issue would make better recognizing the importance of efficient use of energy in terms of high energy conservation measures. The authors have designed and developed a 100 W class Stirling refrigerator for household use. And the prototype machine has been integrated with a 100 litter class refrigerator. The operating characteristics of this Stirling unit or the prototype machine have been evaluated. Moreover, the authors evaluated the machine driving engine mode using ultra-low temperature media. As a result, the operational characteristics of the Stirling cycle machine have been clarified with respect to design factors. These results demonstrate that the Stirling cycle machine is one of the promising candidates as a new refrigeration system or a new generation system.

  19. Oil formula for refrigeration equipment

    Energy Technology Data Exchange (ETDEWEB)

    Warasina, N.; Minakawa, K.; Tanizaki, Y.

    1982-03-26

    Oil used in refrigeration equipment (OFE) contains polyether type synthetic oil with 0.1-3 percent of aromatic antioxidant as an additive; the antioxidant has 1-2 atoms of N or 1 atom N and 1 atom S in the molecule, and 0.1-5% organic Sn compounds. It is preferable to use phenyl-alpha-naphtylamin as the additive, and for the Sn, dibutylcarboxilate Sn or dibutyldilaurinate Sn. It is recommended that a synthetic oil with the following formula: X(O(AO)mY)n, where X=H or the rest of alcohol; A- alkylene C/sub 2/-C/sub 4/; Y=H, alkyl, alkenyl, acyl, benzyl or arile; m=2-100; n=1-6. This OFE has a high chemical stability when in contact with freon or metals at high temperatures for long time periods, and has good lubricating features.

  20. Bearing construction for refrigeration compresssor

    Science.gov (United States)

    Middleton, Marc G.; Nelson, Richard T.

    1988-01-01

    A hermetic refrigeration compressor has a cylinder block and a crankshaft rotatable about a vertical axis to reciprocate a piston in a cylinder on the cylinder block. A separate bearing housing is secured to the central portion of the cylinder block and extends vertically along the crankshaft, where it carries a pair of roller bearings to journal the crankshaft. The crankshaft has a radially extending flange which is journaled by a thrust-type roller bearing above the bearing housing to absorb the vertical forces on the crankshaft so that all three of the roller bearings are between the crankshaft and the bearing housing to maintain and control the close tolerances required by such bearings.

  1. Two-phase flow in refrigeration systems

    CERN Document Server

    Gu, Junjie; Gan, Zhongxue

    2013-01-01

    Two-Phase Flow in Refrigeration Systems presents recent developments from the authors' extensive research programs on two-phase flow in refrigeration systems. This book covers advanced mass and heat transfer and vapor compression refrigeration systems and shows how the performance of an automotive air-conditioning system is affected through results obtained experimentally and theoretically, specifically with consideration of two-phase flow and oil concentration. The book is ideal for university postgraduate students as a textbook, researchers and professors as an academic reference book, and b

  2. A versatile magnetic refrigeration test device

    DEFF Research Database (Denmark)

    Bahl, Christian Robert Haffenden; Petersen, Thomas Frank; Pryds, Nini

    2008-01-01

    A magnetic refrigeration test device has been built and tested. The device allows variation and control of many important experimental parameters, such as the type of heat transfer fluid, the movement of the heat transfer fluid, the timing of the refrigeration cycle, and the magnitude...... of the applied magnetic field. An advanced two-dimensional numerical model has previously been implemented in order to help in the optimization of the design of a refrigeration test device. Qualitative agreement between the results from model and the experimental results is demonstrated for each of the four...... different parameter variations mentioned above. (C) 2008 American Institute of Physics....

  3. Refrigerant charge management in a heat pump water heater

    Science.gov (United States)

    Chen, Jie; Hampton, Justin W.

    2014-06-24

    Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

  4. Dynamic modeling and experimental validation elements of a 30 kW LiBr/H2O single effect absorption chiller for solar application

    International Nuclear Information System (INIS)

    Marc, Olivier; Sinama, Frantz; Praene, Jean-Philippe; Lucas, Franck; Castaing-Lasvignottes, Jean

    2015-01-01

    This paper presents a dynamic modeling of a single-effect absorption chiller working with LiBr–H 2 O solution used in a solar cooling installation operating without any backup systems (hot or cold). In this case, the absorption machine is powered only by a solar collector field. Given the highly variable nature of solar radiation and the building loads, the range of the three source temperatures of the chiller can vary widely since there is no backup system. These fluctuating source temperatures mean that the chiller does not operate in steady state phase during the day. The dynamic modeling of the absorption chiller is therefore very important to predict its performance, taking into account both the transient and steady state phases. The numerical model presented in this paper is based on the mass and energy balances of each component, equations of state and equations of heat transfers. In the first part, this article presents the dynamic modeling of a LiBr/H 2 O absorption chiller. Then, experimental validation elements are proposed to validate pressures and temperatures of the chiller. Finally, a method is presented to optimize the thermal COP according to different levels of refrigerating capacities. - Highlights: • A dynamic absorption chiller model has been developed in this paper. • The model is described and an experimental validation is carried out. • The good agreement between the prediction and the experimental data is presented. • Then the model is used to optimize heat source temperatures to produce different levels of refrigerating capacities.

  5. An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator

    International Nuclear Information System (INIS)

    Aprea, Ciro; Greco, Adriana; Maiorino, Angelo

    2016-01-01

    Highlights: • An experimental comparison between R134A and HFO1234YF is presented. • A domestic refrigerator made to work with R134A is analysed. • The annual energy consumptions of the device are reported. • The energy saving achievable after the drop-in is evaluated. - Abstract: The latest international regulations on the reduction of greenhouse gases are strongly redesigning the scenario of use of refrigerants, gradually eliminating the possibility of employing the HFCs. Among all sectors of refrigeration, one of the most affected by these restrictions is the domestic refrigeration. Although for it have been suggested some solutions, such as the construction of household refrigerator operating with the hydrocarbons, there remains the need to find a substitute for HFC134a. In particular, the substitution may involve both existing machines and already in operation, which cannot be loaded with hydrocarbons, and new devices. With the aim of finding a simple implementation solution, in the present work, it is reported an experimental investigation carried out on a domestic refrigerator designed and built to operate with HFC134a and for which a drop-in with HFO1234yf has been realised. The experimentation has been addressed so as to highlight the behaviour of the system as a result of the drop-in, with a particular interest in the energy performance variation. A slight energy saving has been recorded with HFO1234yf, and an improving of the cooling capacity has been noticed.

  6. New magnetic refrigeration materials for the liquefaction of hydrogen

    International Nuclear Information System (INIS)

    Gschneidner, K.A.; Takeya, H.; Moorman, J.O.; Pecharsky, V.K.; Malik, S.K.; Zimm, C.B.

    1994-01-01

    Five heavy lanthanide ferromagnetic intermetallic compounds were studied as potential magnetic refrigerants for the liquefaction of hydrogen gas. (Dy 0.5 Er 0.5 )Al 2 and TbNi 2 appear to be better refrigerants than GdPd for a Joule-Brayton cycle refrigerator, while (Gd 0.54 Er 0.46 )AlNi seems to be a suitable refrigerant for an Ericsson cycle refrigerator

  7. Experimental investigation of the ecological hybrid refrigeration cycle

    Science.gov (United States)

    Cyklis, Piotr; Kantor, Ryszard; Ryncarz, Tomasz; Górski, Bogusław; Duda, Roman

    2014-09-01

    The requirements for environmentally friendly refrigerants promote application of CO2 and water as working fluids. However there are two problems related to that, namely high temperature limit for CO2 in condenser due to the low critical temperature, and low temperature limit for water being the result of high triple point temperature. This can be avoided by application of the hybrid adsorption-compression system, where water is the working fluid in the adsorption high temperature cycle used to cool down the CO2 compression cycle condenser. The adsorption process is powered with a low temperature renewable heat source as solar collectors or other waste heat source. The refrigeration system integrating adsorption and compression system has been designed and constructed in the Laboratory of Thermodynamics and Thermal Machine Measurements of Cracow University of Technology. The heat source for adsorption system consists of 16 tube tulbular collectors. The CO2 compression low temperature cycle is based on two parallel compressors with frequency inverter. Energy efficiency and TEWI of this hybrid system is quite promising in comparison with the compression only systems.

  8. Additive Manufacturing of Tooling for Refrigeration Cabinet Foaming Processes

    Energy Technology Data Exchange (ETDEWEB)

    Post, Brian K [ORNL; Nuttall, David [ORNL; Cukier, Michael Z [ORNL; Hile, Michael B [ORNL

    2016-07-29

    The primary objective of this project was to leverage the Big Area Additive Manufacturing (BAAM) process and materials into a long term, quick change tooling concept to drastically reduce product lead and development timelines and costs. Current refrigeration foam molds are complicated to manufacture involving casting several aluminum parts in an approximate shape, machining components of the molds and post fitting and shimming of the parts in an articulated fixture. The total process timeline can take over 6 months. The foaming process is slower than required for production, therefore multiple fixtures, 10 to 27, are required per refrigerator model. Molds are particular to a specific product configuration making mixed model assembly challenging for sequencing, mold changes or auto changeover features. The initial goal was to create a tool leveraging the ORNL materials and additive process to build a tool in 4 to 6 weeks or less. A secondary goal was to create common fixture cores and provide lightweight fixture sections that could be revised in a very short time to increase equipment flexibility reduce lead times, lower the barriers to first production trials, and reduce tooling costs.

  9. Model Based Control of Refrigeration Systems

    DEFF Research Database (Denmark)

    Larsen, Lars Finn Sloth

    control is to let an optimization procedure take over the task of operating the refrigeration system and thereby replace the role of the operator in the traditional control structure. In the context of refrigeration systems, the idea is to divide the optimizing control structure into two parts: A part......Today refrigeration control systems consist of a number of self-contained distributed control loops that during the past years has been optimized obtaining a high performance of the individual subsystems, thus disregarding cross-couplings as well dynamically as statically. The supervisory control...... of the supermarket refrigeration systems therefore greatly relies on a human operator to detect and accommodate failures, and to optimize system performance under varying operational condition. Today these functions are maintained by monitoring centres located all over the world. Initiated by the growing need...

  10. Exergetic sustainability evaluation of irreversible Carnot refrigerator

    Science.gov (United States)

    Açıkkalp, Emin

    2015-10-01

    Purpose of this paper is to assess irreversible refrigeration cycle by using exergetic sustainability index. In literature, there is no application of exergetic sustainability index for the refrigerators and, indeed, this index has not been derived for refrigerators. In this study, exergetic sustainability indicator is presented for the refrigeration cycle and its relationships with other thermodynamics parameters including COP, exergy efficiency, cooling load, exergy destruction, ecological function and work input are investigated. Calculations are conducted for endoreversible and reversible cycles and then results obtained from the ecological function are compared. It is found that exergy efficiency, exergetic sustainable index reduce 47.595% and 59.689% and rising at the COP is 99.888% is obtained for endoreversible cycle. Similarly, exergy efficiency and exergetic sustainability index reduce 90.163% and 93.711% and rising of the COP is equal to 99.362%.

  11. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  12. Defrost Temperature Termination in Supermarket Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

    2011-11-01

    The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

  13. Refrigeration system having standing wave compressor

    Science.gov (United States)

    Lucas, Timothy S.

    1992-01-01

    A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

  14. ESO2 Optimization of Supermarket Refrigeration Systems

    DEFF Research Database (Denmark)

    Petersen, Lars Norbert; Madsen, Henrik; Heerup, Christian

    Supermarket refrigeration systems consists of a number of display cases, cooling cabinets and cold rooms connected to a central compressor pack. This configuration saves energy compared to placing a compressor at each cooling site. The classical control setup of a supermarket refrigeration system...... in the supermarket. The first approach to solve this problem is to design an overall control system which coordinates the compressor capacity and the current refrigeration load. The drawback of this approach is the complexity of the single controller. The solution is investigated in the first part of the report....... A second solution is investigated where only the compressor control is considered. This controller try to feed-forward the measured disturbances, i.e. opening and closing of the cooling site AKV’s. Last a performance analysis of the refrigeration system is performed....

  15. Freezing and refrigerated storage in fisheries

    National Research Council Canada - National Science Library

    Johnston, W. A

    1994-01-01

    ...; the factors affecting cold storage conditions, etc. In addition, the publication describes the methods used to calculate cold storage refrigeration loads as well as the costs of freezing and cold storage...

  16. ENERGY STAR Laboratory Grade Refrigerators and Freezers

    Data.gov (United States)

    U.S. Environmental Protection Agency — Certified models meet all ENERGY STAR requirements as listed in the Version 1.0 ENERGY STAR Program Requirements for Laboratory Grade Refrigerators and Freezers that...

  17. High Efficiency Refrigeration Process, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A refrigeration cycle is proposed for development which can reduce compressor work and increase cooling effect, by eliminating a portion of the irreversabilities...

  18. Vaccine refrigeration: thinking outside of the box.

    Science.gov (United States)

    McColloster, Patrick J; Martin-de-Nicolas, Andres

    2014-01-01

    This commentary reviews recent changes in Centers for Disease Control (CDC) vaccine storage guidelines that were developed in response to an investigative report by the Office of the Inspector General. The use of temperature data loggers with probes residing in glycol vials is advised along with storing vaccines in pharmaceutical refrigerators. These refrigerators provide good thermal distribution but can warm to 8 °C in less than one hour after the power is discontinued. Consequently, electric grid instability influences appropriate refrigerator selection and the need for power back-up. System Average Interruption Duration Index (SAIDI) values quantify this instability and can be used to formulate region-specific guidelines. A novel aftermarket refrigerator with a battery back-up power supply and microprocessor control system is also described.

  19. Designing a magnet for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bjørk, Rasmus

    This thesis investigates the design and optimization of a permanent magnet assembly for use in a magnetic refrigeration device. The heart of magnetic refrigeration is the adiabatic temperature change in the magnetocaloric material which is caused by the magnetic field. In order to design an ideal...... magnet assembly the magnetocaloric materials and the refrigeration process itself and their properties and performance as a function of magnetic field are investigated. For the magnetocaloric materials it is the magnetization, specific heat capacity and adiabatic temperature that are investigated...... as functions of the magnetic field. Following this the process utilized by a magnetic refrigerator to provide cooling is investigated using a publicly available one dimensional numerical model. This process is called active magnetic regeneration (AMR). The aim is to determine the performance of the AMR...

  20. Experimental installation of refrigeration solar-first results; Instalacion experimental de refrigeracion solar-primeros resultados

    Energy Technology Data Exchange (ETDEWEB)

    Moone, C.; Guallar, J.; Alonso, S.; Palacin, F.

    2008-07-01

    In this article they are and the first results of an installation of solar refrigeration composed by a field of flat solar collector are analysed and absorption chillers of simple effect (BrLi-H{sub 2}O), used to give cold to a gymnasium of the university sport pavilion. The data correspond to the registered experimental values during the summer of 2007 (months of June, Julio and August). (Author)

  1. A cryogenic axial-centrifugal compressor for superfluid helium refrigeration

    CERN Document Server

    Decker, L; Schustr, P; Vins, M; Brunovsky, I; Lebrun, P; Tavian, L

    1997-01-01

    CERN's new project, the Large Hadron Collider (LHC), will use superfluid helium as coolant for its high-field superconducting magnets and therefore require large capacity refrigeration at 1.8 K. This may only be achieved by subatmospheric compression of gaseous helium at cryogenic temperature. To stimulate development of this technology, CERN has procured from industry prototype Cold Compressor Units (CCU). This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating under low-pressure helium at ambient temperature. The machine has been commissioned and is now in operation. After describing basic constructional features of the compressor, we report on measured performance.

  2. A review of linear compressors for refrigeration

    OpenAIRE

    Liang, Kun

    2017-01-01

    Linear compressor has no crank mechanism compared with conventional reciprocating compressor. This allows higher efficiency, oil-free operation, lower cost and smaller size when linear compressors are used for vapour compression refrigeration (VCR) system. Typically, a linear compressor consists of a linear motor (connected to a piston) and suspension springs, operated at resonant frequency. This paper presents a review of linear compressors for refrigeration system. Different designs and mod...

  3. Commercial refrigeration - An overview of current status

    OpenAIRE

    Mota Babiloni, Adrián; Navarro Esbri, Joaquin; BARRAGÁN CERVERA, ÁNGEL; Moles, Francisco; Peris, Bernardo; Verdú Martín, Gumersindo Jesús

    2015-01-01

    Commercial Refrigeration comprises food freezing and conservation in retail stores and supermarkets, so, it is one of the most relevant energy consumption sectors, and its relevance is increasing. This paper reviews the most recent developments in commercial refrigeration available in literature and presents a good amount of results provided these systems, covering some advantages and disadvantages in systems and working fluids. Latest researches are focused on energy savings to reduce CO2 in...

  4. Acute lung injury following refrigeration coil deicing.

    Science.gov (United States)

    McKeown, Nathanael J; Burton, Brent T

    2012-03-01

    We report a case of a worker who developed ALI requiring mechanical ventilatory support after attempting to melt ice condensate by applying the flame of an oxy-acetylene torch to refrigeration coils charged with a halocarbon refrigerant in a closed environment. A discussion of possible etiologies are discussed, including phosgene, carbonyl fluoride, and nitrogen oxides. Primary prevention with adequate respiratory protection is recommended whenever deicing is performed in a closed space environment.

  5. Active Sensor Configuration Validation for Refrigeration Systems

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Blanke, Mogens; Niemann, Hans Henrik

    2010-01-01

    Major faults in the commissioning phase of refrigeration systems are caused by defects related to sensors. With a number of similar sensors available that do not differ by type but only by spatial location in the plant, interchange of sensors is a common defect. With sensors being used quite...... identify the sensor configuration. The method as such is generic and is shown in the paper to work convincingly on refrigeration systems with significant nonlinear behaviors...

  6. A miniature adsorption3HE refrigerator

    International Nuclear Information System (INIS)

    Duband, L.; Ravex, A.; Lange, A.

    1991-01-01

    A self-contained, recyclable laboratory 3 He refrigerator has been developed. The refrigerator is very compact, portable and is designed to be safe and reliable. The unit can easily be installed on the cold plate of a superfluid 4 He cryostat. Once bolted on the cold plate, operation of the refrigerator is controlled by a single heater. In this new design the refrigerator has a cylindrical geometry. The adsorption pump is placed above the condensation point to prevent convection during the condensation phase and to improve the pumping speed. The inhibition of convection reduces the load on the 4 He bath and increases the condensation efficiency. This refrigeration technique has great potential for space applications. The absence of moving parts makes the system reliable and vibration free. Its simplicity and the absence of external components facilitate its integration on a cryostat. In fact, a rocket-borne 3 He refrigerator has already been successfully flown and has demonstrated the feasibility of this method

  7. Computer modeling of commercial refrigerated warehouse facilities

    International Nuclear Information System (INIS)

    Nicoulin, C.V.; Jacobs, P.C.; Tory, S.

    1997-01-01

    The use of computer models to simulate the energy performance of large commercial refrigeration systems typically found in food processing facilities is an area of engineering practice that has seen little development to date. Current techniques employed in predicting energy consumption by such systems have focused on temperature bin methods of analysis. Existing simulation tools such as DOE2 are designed to model commercial buildings and grocery store refrigeration systems. The HVAC and Refrigeration system performance models in these simulations tools model equipment common to commercial buildings and groceries, and respond to energy-efficiency measures likely to be applied to these building types. The applicability of traditional building energy simulation tools to model refrigerated warehouse performance and analyze energy-saving options is limited. The paper will present the results of modeling work undertaken to evaluate energy savings resulting from incentives offered by a California utility to its Refrigerated Warehouse Program participants. The TRNSYS general-purpose transient simulation model was used to predict facility performance and estimate program savings. Custom TRNSYS components were developed to address modeling issues specific to refrigerated warehouse systems, including warehouse loading door infiltration calculations, an evaporator model, single-state and multi-stage compressor models, evaporative condenser models, and defrost energy requirements. The main focus of the paper will be on the modeling approach. The results from the computer simulations, along with overall program impact evaluation results, will also be presented

  8. Sustainable machining

    CERN Document Server

    2017-01-01

    This book provides an overview on current sustainable machining. Its chapters cover the concept in economic, social and environmental dimensions. It provides the reader with proper ways to handle several pollutants produced during the machining process. The book is useful on both undergraduate and postgraduate levels and it is of interest to all those working with manufacturing and machining technology.

  9. Refrigeration-Induced Binding of von Willebrand Factor Facilitates Fast Clearance of Refrigerated Platelets.

    Science.gov (United States)

    Chen, Wenchun; Druzak, Samuel A; Wang, Yingchun; Josephson, Cassandra D; Hoffmeister, Karin M; Ware, Jerry; Li, Renhao

    2017-12-01

    Apheresis platelets for transfusion treatment are currently stored at room temperature because after refrigeration platelets are rapidly cleared on transfusion. In this study, the role of von Willebrand factor (VWF) in the clearance of refrigerated platelets is addressed. Human and murine platelets were refrigerated in gas-permeable bags at 4°C for 24 hours. VWF binding, platelet signaling events, and platelet post-transfusion recovery and survival were measured. After refrigeration, the binding of plasma VWF to platelets was drastically increased, confirming earlier studies. The binding was blocked by peptide OS1 that bound specifically to platelet glycoprotein (GP)Ibα and was absent in VWF - / - plasma. Although surface expression of GPIbα was reduced after refrigeration, refrigeration-induced VWF binding under physiological shear induced unfolding of the GPIbα mechanosensory domain on the platelet, as evidenced by increased exposure of a linear epitope therein. Refrigeration and shear treatment also induced small elevation of intracellular Ca 2+ , phosphatidylserine exposure, and desialylation of platelets, which were absent in VWF -/- platelets or inhibited by OS1, which is a monomeric 11-residue peptide (CTERMALHNLC). Furthermore, refrigerated VWF -/- platelets displayed increased post-transfusion recovery and survival than wild-type ones. Similarly, adding OS1 to transgenic murine platelets expressing only human GPIbα during refrigeration improved their post-transfusion recovery and survival. Refrigeration-induced binding of VWF to platelets facilitates their rapid clearance by inducing GPIbα-mediated signaling. Our results suggest that inhibition of the VWF-GPIbα interaction may be a potential strategy to enable refrigeration of platelets for transfusion treatment. © 2017 American Heart Association, Inc.

  10. Development of a novel refrigeration system for refrigerated trucks incorporating phase change material

    International Nuclear Information System (INIS)

    Liu, Ming; Saman, Wasim; Bruno, Frank

    2012-01-01

    Highlights: ► A refrigeration system having low energy cost and producing no local greenhouse gas emission. ► A PCM is experimentally developed which is able to maintain the refrigerated truck at −18 °C. ► A TRNSYS model is developed to simulate the proposed refrigeration system. -- Abstract: An innovative refrigeration system incorporating phase change material (PCM) is proposed to maintain refrigerated trucks at the desired thermal conditions. The advantage of using PCM to maintain low temperatures is that a conventional refrigeration system does not have to be located on-board the vehicle. In addition, the system consumes less energy and produces much lower local greenhouse gas (GHG) emissions. The phase change thermal storage unit (PCTSU) is charged by a refrigeration unit located off the vehicle when stationary. The PCM is discharged and provides cooling when in service. A new PCM with a lower cost than currently available PCMs was developed, suitable for maintaining the refrigerated truck at a temperature of −18 °C. The PCM has a melting temperature of −26.7 °C and a latent heat of 154.4 kJ kg −1 . A prototype system was constructed and test results proved that the proposed refrigeration system is feasible for mobile transport. An analysis shows that delivery of refrigerated products can be made with a PCM system having a weight comparable to that of an on board conventional refrigeration system with less than half of the energy cost.

  11. Simulated performance of biomass gasification based combined power and refrigeration plant for community scale application

    Science.gov (United States)

    Chattopadhyay, S.; Mondal, P.; Ghosh, S.

    2016-07-01

    Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR) cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (rp) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio and GT-TIT.

  12. Improving the energy efficiency of industrial refrigeration systems

    International Nuclear Information System (INIS)

    Oh, Jin-Sik; Binns, Michael; Park, Sangmin; Kim, Jin-Kuk

    2016-01-01

    Various retrofit design options are available for improving the energy efficiency and economics of industrial refrigeration systems. This study considers a novel retrofit option using a mixed refrigerant (MR) in refrigeration cycles designed for use with a pure refrigerant (PR). In this way energy savings can be realized by switching refrigerants without requiring extensive and expensive reconfiguration of equipment. Hence, the aim here is to test the common thinking that equipment should always be extensively reconfigured when switching from pure to mixed refrigerants. To determine the most energy-efficient operating conditions for each refrigeration design an optimization framework is utilized linking a process simulator with an external optimization method. A case study is presented to demonstrate how the proposed process modeling and optimization framework can be applied and to illustrate the economic benefits of using the retrofit design options considered here. For the case considered in this paper, savings of shaft power required for the refrigeration cycle can be achieved from 16.3% to 27.2% when the pure refrigerant is replaced with mixed refrigerants and operating conditions are re-optimized. - Highlights: • Design methods for the design of refrigeration cycles in retrofit cases. • Consideration of mixed refrigerants to the existing multi-level pure-refrigerant cycles. • Optimization of refrigeration cycles with integrated use of a process simulator with an optimizer.

  13. SIMULATION RESULTS OF SINGLE REFRIGERANTS FOR USE IN A DUAL-CIRCUIT REFRIGERATOR/FREEZER

    Science.gov (United States)

    The paper reviews the refrigerant/freezer (RF) design and refrigerant selection process that is necessary to design an energy efficient RF that does not use fully halogenated chlorofluorocarbons (CFCs). EPA is interested in phasing out CFCs in RFs to minimize stratospheric ozone ...

  14. Review of magnetic refrigeration system as alternative to conventional refrigeration system

    Science.gov (United States)

    Mezaal, N. A.; Osintsev, K. V.; Zhirgalova, T. B.

    2017-10-01

    The refrigeration system is one of the most important systems in industry. Developers are constantly seeking for how to avoid the damage to the environment. Magnetic refrigeration is an emerging, environment-friendly technology based on a magnetic solid that acts as a refrigerant by magneto-caloric effect (MCE). In the case of ferromagnetic materials, MCE warms as the magnetic moments of the atom are aligned by the application of a magnetic field. There are two types of magnetic phase changes that may occur at the Curie point: first order magnetic transition (FOMT) and second order magnetic transition (SOMT). The reference cycle for magnetic refrigeration is AMR (Active Magnetic Regenerative cycle), where the magnetic material matrix works both as a refrigerating medium and as a heat regenerating medium, while the fluid flowing in the porous matrix works as a heat transfer medium. Regeneration can be accomplished by blowing a heat transfer fluid in a reciprocating fashion through the regenerator made of magnetocaloric material that is alternately magnetized and demagnetized. Many magnetic refrigeration prototypes with different designs and software models have been built in different parts of the world. In this paper, the authors try to shed light on the magnetic refrigeration and show its effectiveness compared with conventional refrigeration methods.

  15. HFC perspectives in air-conditioning and refrigeration; Perspectives HFC en A/C et refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Fauvarque, P. [ELF Atochem, Centre d`Application de Lavallois, 92 (France)

    1997-12-31

    This paper is a series of transparencies dealing with the development of substitutes for the replacement of the R-22 refrigerant in air-conditioning systems (R-134a, R-407C, R-410A), and in industrial refrigeration systems of agriculture and food industry (R-134a and R-404A). (J.S.)

  16. OPTIMIZATION OF A DOUBLE EFFECT LIBR-H20 ABSORPTION ...

    African Journals Online (AJOL)

    In the double-effect LiBr-H,0 absorption refrigeration cycle, weak solution leaving the. Absorber is pumped to the pressure of Generator 1,. Fig. l. External heat supplied to the weak solution in. Generator 1 releases water vapor from the solution. To reduce the quantity of external heat required by. Generator 1 and thus ...

  17. Laser refrigeration of hydrothermal nanocrystals in physiological media.

    Science.gov (United States)

    Roder, Paden B; Smith, Bennett E; Zhou, Xuezhe; Crane, Matthew J; Pauzauskie, Peter J

    2015-12-08

    Coherent laser radiation has enabled many scientific and technological breakthroughs including Bose-Einstein condensates, ultrafast spectroscopy, superresolution optical microscopy, photothermal therapy, and long-distance telecommunications. However, it has remained a challenge to refrigerate liquid media (including physiological buffers) during laser illumination due to significant background solvent absorption and the rapid (∼ ps) nonradiative vibrational relaxation of molecular electronic excited states. Here we demonstrate that single-beam laser trapping can be used to induce and quantify the local refrigeration of physiological media by >10 °C following the emission of photoluminescence from upconverting yttrium lithium fluoride (YLF) nanocrystals. A simple, low-cost hydrothermal approach is used to synthesize polycrystalline particles with sizes ranging from 1 μm. A tunable, near-infrared continuous-wave laser is used to optically trap individual YLF crystals with an irradiance on the order of 1 MW/cm(2). Heat is transported out of the crystal lattice (across the solid-liquid interface) by anti-Stokes (blue-shifted) photons following upconversion of Yb(3+) electronic excited states mediated by the absorption of optical phonons. Temperatures are quantified through analysis of the cold Brownian dynamics of individual nanocrystals in an inhomogeneous temperature field via forward light scattering in the back focal plane. The cold Brownian motion (CBM) analysis of individual YLF crystals indicates local cooling by >21 °C below ambient conditions in D2O, suggesting a range of potential future applications including single-molecule biophysics and integrated photonic, electronic, and microfluidic devices.

  18. Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography

    International Nuclear Information System (INIS)

    Asano, H.; Takenaka, N.; Fujii, T.; Shibata, Y.; Ebisu, T.; Matsubayashi, M.

    1999-01-01

    The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow

  19. Absorption studies

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Absorption studies were once quite popular but hardly anyone does them these days. It is easier to estimate the blood level of the nutrient directly by radioimmunoassay (RIA). However, the information obtained by estimating the blood levels of the nutrients is not the same that can be obtained from the absorption studies. Absorption studies are primarily done to find out whether some of the essential nutrients are absorbed from the gut or not and if they are absorbed, to determine how much is being absorbed. In the advanced countries, these tests were mostly done to detect pernicious anaemia where vitamin B 12 is not absorbed because of the lack of the intrinsic factor in the stomach. In the tropical countries, ''malabsorption syndrome'' is quire common. In this condition, several nutrients like fat, folic acid and vitamin B 12 are not absorbed. It is possible to study absorption of these nutrients by radioisotopic absorption studies

  20. Refrigerated Warehouse Demand Response Strategy Guide

    Energy Technology Data Exchange (ETDEWEB)

    Scott, Doug [VaCom Technologies, San Luis Obispo, CA (United States); Castillo, Rafael [VaCom Technologies, San Luis Obispo, CA (United States); Larson, Kyle [VaCom Technologies, San Luis Obispo, CA (United States); Dobbs, Brian [VaCom Technologies, San Luis Obispo, CA (United States); Olsen, Daniel [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-01

    This guide summarizes demand response measures that can be implemented in refrigerated warehouses. In an appendix, it also addresses related energy efficiency opportunities. Reducing overall grid demand during peak periods and energy consumption has benefits for facility operators, grid operators, utility companies, and society. State wide demand response potential for the refrigerated warehouse sector in California is estimated to be over 22.1 Megawatts. Two categories of demand response strategies are described in this guide: load shifting and load shedding. Load shifting can be accomplished via pre-cooling, capacity limiting, and battery charger load management. Load shedding can be achieved by lighting reduction, demand defrost and defrost termination, infiltration reduction, and shutting down miscellaneous equipment. Estimation of the costs and benefits of demand response participation yields simple payback periods of 2-4 years. To improve demand response performance, it’s suggested to install air curtains and another form of infiltration barrier, such as a rollup door, for the passageways. Further modifications to increase efficiency of the refrigeration unit are also analyzed. A larger condenser can maintain the minimum saturated condensing temperature (SCT) for more hours of the day. Lowering the SCT reduces the compressor lift, which results in an overall increase in refrigeration system capacity and energy efficiency. Another way of saving energy in refrigerated warehouses is eliminating the use of under-floor resistance heaters. A more energy efficient alternative to resistance heaters is to utilize the heat that is being rejected from the condenser through a heat exchanger. These energy efficiency measures improve efficiency either by reducing the required electric energy input for the refrigeration system, by helping to curtail the refrigeration load on the system, or by reducing both the load and required energy input.

  1. A new compressed air energy storage refrigeration system

    International Nuclear Information System (INIS)

    Wang Shenglong; Chen Guangming; Fang Ming; Wang Qin

    2006-01-01

    In this study, a new compressed air energy storage (CAES) refrigeration system is proposed for electrical power load shifting application. It is a combination of a gas refrigeration cycle and a vapor compression refrigeration cycle. Thermodynamic calculations are conducted to investigate the performance of this system. Economic analysis is performed to study the operating cost of the system, and comparison is made with a vapor compression refrigeration system and an ice storage refrigeration system. The results indicate that the CAES refrigeration system has the advantages of simple structure, high efficiency and low operating cost

  2. Alternative solutions for the CFC fluids in the refrigerating systems

    International Nuclear Information System (INIS)

    Ciconkov, Risto

    1997-01-01

    This paper deals with: -Characteristics that the alternative refrigerants should satisfy: chemical, thermal, health, safety, environmental, etc. -A survey of the newest refrigerants on the world market from the biggest well known companies. -Dilemmas about the choice of new refrigerants depending to the appliance in refrigerating systems. -Specific requirements that have to be known concerning the introduction of new refrigerants in exploitation. -Alternative refrigerants with natural origin, their positive and negative characteristics from the aspect of application. -Different viewpoints of the actual situation and perspective developing ways in this field, expecting new, more restrictive regulations to environment qualities. -The role of the national strategy now and in the future. (author)

  3. A study of alternative refrigerants for the refrigeration and air conditioning sector in Mauritius

    Science.gov (United States)

    Dreepaul, R. K.

    2017-11-01

    The most frequently used refrigerants in the refrigeration and air conditioning (RAC) sector in Mauritius are currently hydrochlorofluorocarbons (HCFC) and hydrofluorocarbons (HFC). However, because of their strong influence on global warming and the impact of HCFCs on the ozone layer, refrigerants such as ammonia (NH3), carbon dioxide (CO2) and Hydrocarbons (HC), having minimal impact on the environment, are being considered. So far, HCs have only been safely used in domestic refrigeration. Ammonia has been used mainly for industrial refrigeration whereas CO2 is still under study. In this paper, a comparative study of the various feasible alternatives is presented in a survey that was undertaken with major stake holders in the field. The retrofitting possibility of existing equipment was assessed and safety issues associated with each refrigerant were analysed. The major setback of hydrocarbons as a widely accepted refrigerant is its flammability which was considered as a major safety hazard by the majority of respondents in the survey and the main advantages are the improved equipment coefficient of performance (COP) and better TEWI factor. This resulted in a 12 % drop in energy consumption. Despite the excellent thermodynamic properties of ammonia, its use has mainly been confined to industrial refrigeration due to its toxicity. In Mauritius, the performance of ammonia in air conditioning is being evaluated on a pilot basis. The major setback of carbon dioxide as a refrigerant is the high operating pressure which is considered a safety hazard. The high initial investment cost and the lack of qualified maintenance technician is also an issue. The use of CO2 is mainly being considered in the commercial refrigeration sector.

  4. Experimental results and thermodynamic analysis of a natural gas small scale cogeneration plant for power and refrigeration purposes

    International Nuclear Information System (INIS)

    Bazzo, Edson; Nacif de Carvalho, Alvaro; Matelli, José Alexandre

    2013-01-01

    In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24 °C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at −5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. -- Highlights: • A small scale cogeneration plant for power and refrigeration is proposed and analyzed. • The plant is based on a microturbine and a modified absorption chiller. • The plant is analysed based on 1st and 2nd laws of thermodynamics. • Experimental results are found for different power and refrigeration conditions. • The plant proved to be technically feasible

  5. Application of Best Industry Practices to the Design of Commercial Refrigerators

    Energy Technology Data Exchange (ETDEWEB)

    None

    2002-06-30

    The substantial efficiency improvements which have been realized in residential refrigerators over the last twenty years due to implementation of the National Appliance Energy Conservation Act and changing consumer reactions to energy savings give an indication of the potential for improvement in the commercial sector, where few such efficiency improvements have been made to date. The purchase decision for commercial refrigerators is still focused primarily on first cost and product performance issues such as maximizing storage capacity, quick pulldown, durability, and reliability. The project applied techniques used extensively to reduce energy use in residential refrigeration to a commercial reach-in refrigerator. The results will also be applicable to other commercial refrigeration equipment, such as refrigerated vending machines, reach-in freezers, beverage merchandisers, etc. The project described in this paper was a collaboration involving the Appliance and Building Technology Sector of TIAX, the Delfield Company, and the U. S. Department of Energy's Office of Building Technologies. Funding was provided by DOE through Cooperative Agreement No. DE-FC26-00NT41000. The program plan and schedule were structured to assure successful integration of the TIAX work on development of efficient design concepts into Delfield's simultaneous development of the Vantage product line. The energy-saving design options evaluated as part of the development included brushless DC and PSC fan motors, high-efficiency compressors, variable-speed compressor technology, cabinet thermal improvement (particularly in the face frame area), increased insulation thickness, a trap for the condensate line, improved insulation, reduced-wattage antisweat heaters, non-electric antisweat heating, off-cycle defrost termination, rifled heat exchanger tubing, and system optimization (selection of heat exchangers, fans, and subcooling, superheat, and suction temperatures for efficient

  6. A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling

    Science.gov (United States)

    Miller, Franklin K.

    2012-01-01

    A report describes a pulse tube refrigerator that uses a mixture of He-3 and superfluid He-4 to cool to temperatures below 300 mK, while rejecting heat at temperatures up to 1.7 K. The refrigerator is driven by a novel thermodynamically reversible pump that is capable of pumping the He-3 He-4 mixture without the need for moving parts. The refrigerator consists of a reversible thermal magnetic pump module, two warm heat exchangers, a recuperative heat exchanger, two cold heat exchangers, two pulse tubes, and an orifice. It is two superfluid pulse tubes that run 180 out of phase. All components of this machine except the reversible thermal pump have been demonstrated at least as proof-of-concept physical models in previous superfluid Stirling cycle machines. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters.

  7. The multiple meanings of the Stefan-number (and relatives) in refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Ziegler, F. [Technische Universitaet Berlin, Institut fuer Energietechnik, KT 2, Marchstrasse 18, D-10587 Berlin (Germany)

    2010-11-15

    The Stefan-number is one out of the multitude of dimensionless numbers which predominantly are used in chemical engineering or heat and mass transfer problems. It relates sensible heat to latent heat and is a key number in solving the problem of heat transfer during solidification or melting. However, numbers similar to this show up also when several thermodynamic problems or relationships in refrigeration engineering are analyzed. Using the Stefan-number it can be distinguished if a refrigerant superheats or condenses during compression, it gives the size of the throttling loss, and it helps to decide if a suction line heat exchanger is beneficial or not. For absorption heat pumping, it allows to quantify the most important loss mechanism, the solution heat exchanger loss. Of course, all this information can be acquired in different ways - and maybe in more precise ways - also, but at least for teaching the basics of refrigeration the Stefan-number is simple to use and very easy to understand. In this paper, the different ways of how to use the Stefan-number in teaching and understanding thermodynamics of refrigerants are presented. (author)

  8. Influence of Oil on Refrigerant Evaporator Performance

    Science.gov (United States)

    Kim, Jong-Soo; Nagata, Karsuya; Katsuta, Masafumi; Tomosugi, Hiroyuki; Kikuchi, Kouichiro; Horichi, Toshiaki

    In vapor compression refrigeration system using oil-lubricated compressors, some amount of oil is always circulated through the system. Oil circulation can have a significant influence on the evaporator performance of automotive air conditioner which is especially required to cool quickly the car interior after a period standing in the sun. An experimental investigation was carried out an electrically heated horizontal tube to measure local heat transfer coefficients for various flow rates and heat fluxes during forced convection boiling of pure refrigerant R12 and refrigerant-oil mixtures (0-11% oil concentration by weight) and the results were compared with oil free performance. Local heat transfer coefficients increased at the region of low vapor quality by the addition of oil. On the other hand, because the oil-rich liquid film was formed on the heat transfer surface, heat transfer coefficients gradually decreased as the vapor quality became higher. Average heat transfer coefficient reached a maximum at about 4% oil concentration and this trend agreed well with the results of Green and Furse. Previous correlations, using the properties of the refrigerant-oil mixture, could not predict satisfactorily the local heat transfer coefficients data. New correlation modified by oil concentration factor was developed for predicting the corresponding heat transfer coefficient for refrigerant-oil mixture convection boiling. The maximum percent deviation between predicted and measured heat transfer coefficient was within ±30%.

  9. Data-Driven Control of Refrigeration System

    DEFF Research Database (Denmark)

    Vinther, Kasper

    Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive and it is import......Refrigeration is used in a wide range of applications, e.g., for storage of food at low temperatures to prolong shelf life and in air conditioning for occupancy comfort. The main focus of this thesis is control of supermarket refrigeration systems. This market is very competitive...... of data-driven control strategies with a higher plug and play potential. One of the main control challenges in refrigeration systems is proper control of superheat for efficient and safe operation of the system. This task can be performed by an electronic expansion valve and requires two sensors, which...... in this thesis. As a result, learning-based precool strategies are proposed, which utilize the thermal storage capability in foodstuff to shift some of the peak load to less loaded hours. The precool time and period can continuously be updated based on data from previous days and the data-driven solutions...

  10. Folate absorption

    International Nuclear Information System (INIS)

    Baker, S.J.

    1976-01-01

    Folate is the generic term given to numerous compounds of pteroic acid with glutamic acid. Knowledge of absorption is limited because of the complexities introduced by the variety of compounds and because of the inadequacy of investigational methods. Two assay methods are in use, namely microbiological and radioactive. Techniques used to study absorption include measurement of urinary excretion, serum concentration, faecal excretion, intestinal perfusion, and haematological response. It is probably necessary to test absorption of both pteroylmonoglutamic acid and one or more polyglutamates, and such tests would be facilitated by availability of synthesized compounds labelled with radioactive tracers at specifically selected sites. (author)

  11. Simple machines

    CERN Document Server

    Graybill, George

    2007-01-01

    Just how simple are simple machines? With our ready-to-use resource, they are simple to teach and easy to learn! Chocked full of information and activities, we begin with a look at force, motion and work, and examples of simple machines in daily life are given. With this background, we move on to different kinds of simple machines including: Levers, Inclined Planes, Wedges, Screws, Pulleys, and Wheels and Axles. An exploration of some compound machines follows, such as the can opener. Our resource is a real time-saver as all the reading passages, student activities are provided. Presented in s

  12. Narrative absorption

    DEFF Research Database (Denmark)

    Narrative Absorption brings together research from the social sciences and Humanities to solve a number of mysteries: Most of us will have had those moments, of being totally absorbed in a book, a movie, or computer game. Typically we do not have any idea about how we ended up in such a state. Nor...... do we fully realize how we might have changed as we return for the fictional worlds we have visited. The feeling of being absorbed is one of the most illusive and transient feelings, but also one that motivates audiences to spend considerable amounts of time in narrative worlds, and one...... that is central to our understanding of the effects of narratives on beliefs and behavior. Key specialists inform the reader of this book about the nature of the peculiar state of consciousness during episodes of absorption, the perception of absorption in history, the role of absorption in meaningful experiences...

  13. COP improvement of refrigerator/freezers, air-conditioners, and heat pumps using nonazeotropic refrigerant mixtures

    Science.gov (United States)

    Westra, Douglas G.

    1993-01-01

    With the February, 1992 announcement by President Bush to move the deadline for outlawing CFC (chloro-fluoro-carbon) refrigerants from the year 2000 to the year 1996, the refrigeration and air-conditioning industries have been accelerating their efforts to find alternative refrigerants. Many of the alternative refrigerants being evaluated require synthetic lubricants, are less efficient, and have toxicity problems. One option to developing new, alternative refrigerants is to combine existing non-CFC refrigerants to form a nonazeotropic mixture, with the concentration optimized for the given application so that system COP (Coefficient Of Performance) may be maintained or even improved. This paper will discuss the dilemma that industry is facing regarding CFC phase-out and the problems associated with CFC alternatives presently under development. A definition of nonazeotropic mixtures will be provided, and the characteristics and COP benefits of nonazeotropic refrigerant mixtures will be explained using thermodynamic principles. Limitations and disadvantages of nonazeotropic mixtures will be discussed, and example systems using such mixtures will be reviewed.

  14. Performance of a Throttle Cycle Refrigerator with Nitrogen-Hydrocarbon and Argon-Hydrocarbon Mixtures

    Science.gov (United States)

    Venkatarathnam, G.; Senthil Kumar, P.; Srinivasa Murthy, S.

    2004-06-01

    Throttle cycle refrigerators are a class of vapor compression refrigerators that can provide refrigeration at cryogenic temperatures and operate with refrigerant mixtures. The performance of our prototype refrigerators with nitrogen-hydrocarbon, nitrogen-hydrocarbon-helium and argon-hydrocarbon refrigerant mixtures is presented in this paper.

  15. Refrigerant pressurization system with a two-phase condensing ejector

    Science.gov (United States)

    Bergander, Mark [Madison, CT

    2009-07-14

    A refrigerant pressurization system including an ejector having a first conduit for flowing a liquid refrigerant therethrough and a nozzle for accelerating a vapor refrigerant therethrough. The first conduit is positioned such that the liquid refrigerant is discharged from the first conduit into the nozzle. The ejector includes a mixing chamber for condensing the vapor refrigerant. The mixing chamber comprises at least a portion of the nozzle and transitions into a second conduit having a substantially constant cross sectional area. The condensation of the vapor refrigerant in the mixing chamber causes the refrigerant mixture in at least a portion of the mixing chamber to be at a pressure greater than that of the refrigerant entering the nozzle and greater than that entering the first conduit.

  16. A Cold Cycle Dilution Refrigerator for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The cold cycle dilution refrigerator is a continuous refrigerator capable of cooling to temperatures below 100 mK that makes use of a novel thermal magnetic pump....

  17. Retail Food Refrigeration and the Phaseout of HCFC-22

    Science.gov (United States)

    Provides information on the HCFC phaseout that is relevant to food retailers, including alternatives to the use of HCFC-22 in retail food refrigeration, other refrigerant regulations, and resources for more information.

  18. Refrigerator operating experience on whole body MRI magnet systems

    International Nuclear Information System (INIS)

    Murray, F.S.; Hwang, K.F.; Markiewicz, W.D.

    1986-01-01

    Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented

  19. Transitioning to Low-GWP Alternatives in Transport Refrigeration

    Science.gov (United States)

    This fact sheet provides information on low-GWP refrigerant and foam blowing agent alternatives used in transport refrigeration equipment. It discusses HFC alternatives, market trends, challenges to market entry for alternatives, and potential solutions.

  20. Basics of Low-temperature Refrigeration

    CERN Document Server

    Alekseev, A.

    2014-07-17

    This chapter gives an overview of the principles of low temperature refrigeration and the thermodynamics behind it. Basic cryogenic processes - Joule-Thomoson process, Brayton process as well as Claude process - are described and compared. A typical helium laboratory refrigerator based on Claude process is used as a typical example of a low-temperature refrigeration system. A description of the hardware components for helium liquefaction is an important part of this paper, because the design of the main hardware components (compressors, turbines, heat exchangers, pumps, adsorbers, etc.) provides the input for cost calculation, as well as enables to estimate the reliability of the plant and the maintenance expenses. All these numbers are necessary to calculate the economics of a low temperature application.

  1. Modelling refrigerant distribution in microchannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke; Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    of the refrigerant distribution is carried out for two channels in parallel and for two different cases. In the first case maldistribution of the inlet quality into the channels is considered, and in the second case a non-uniform airflow on the secondary side is considered. In both cases the total mixed superheat...... out of the evaporator is kept constant. It is shown that the cooling capacity of the evaporator is reduced significantly, both in the case of unevenly distributed inlet quality and for the case of non-uniform airflow on the outside of the channels.......The effects of refrigerant maldistribution in parallel evaporator channels on the heat exchanger performance are investigated numerically. For this purpose a 1D steady state model of refrigerant R134a evaporating in a microchannel tube is built and validated against other evaporator models. A study...

  2. Systematic modelling and simulation of refrigeration systems

    DEFF Research Database (Denmark)

    Rasmussen, Bjarne D.; Jakobsen, Arne

    1998-01-01

    The task of developing a simulation model of a refrigeration system can be very difficult and time consuming. In order for this process to be effective, a systematic method for developing the system model is required. This method should aim at guiding the developer to clarify the purpose of the s......The task of developing a simulation model of a refrigeration system can be very difficult and time consuming. In order for this process to be effective, a systematic method for developing the system model is required. This method should aim at guiding the developer to clarify the purpose...... of the simulation, to select appropriate component models and to set up the equations in a well-arranged way. In this paper the outline of such a method is proposed and examples showing the use of this method for simulation of refrigeration systems are given....

  3. Toxicity Data to Determine Refrigerant Concentration Limits

    Energy Technology Data Exchange (ETDEWEB)

    Calm, James M.

    2000-09-30

    This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

  4. Experimental Study of Explosion Limits of Refrigerants and Lubricants’ Mixture

    OpenAIRE

    Shi, Y.Q; Chen, Guangming; Chen, Q

    2012-01-01

    The explosion limits of refrigerants and lubricants’ mixture were studied. The refrigerants like R161, R1234yf and R152a are combustible. Lubricants, to a certain extent, are combustion-supporting. In many actual conditions, lubricants and refrigerants are mixed together. In this paper, a test device which can be run automatically was established according to ASTM E681-09, and the explosive experimental of refrigerants and lubricants’ mixture in some ratio was studied. By altering the proport...

  5. Variable speed hermetic reciprocating compressors for domestic refrigerators

    DEFF Research Database (Denmark)

    Rasmussen, Bjarne D.

    1998-01-01

    This article describes the results of a both theoretical and experimental investigation of the performance of variable speed hermetic reciprocating compressors for domestic refrigerators. The investigation was performed as a part of a larger research project with the objective of reducing...... the energy consumption of domestic refrigerators by increasing the efficiency of the refrigeration system. The improvement of the system efficiency was to be obtained by introducing continuous operation and use variable speed compressors for controlling the capacity of the refrigeration system...

  6. Designing a magnet for magnetic refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Bjoerk, R.

    2010-03-15

    This thesis investigates the design and optimization of a permanent magnet assembly for use in a magnetic refrigeration device. The heart of magnetic refrigeration is the adiabatic temperature change in the magnetocaloric material which is caused by the magnetic field. In order to design an ideal magnet assembly the magnetocaloric materials and the refrigeration process itself and their properties and performance as a function of magnetic field are investigated. For the magnetocaloric materials it is the magnetization, specific heat capacity and adiabatic temperature that are investigated as functions of the magnetic field. Following this the process utilized by a magnetic refrigerator to provide cooling is investigated using a publicly available one dimensional numerical model. This process is called active magnetic regeneration (AMR). The aim is to determine the performance of the AMR as a function of the magnetic field in order to learn the properties of the optimal magnet assembly. The performance of the AMR as a function of the synchronization and width of the magnetic field with respect to the AMR cycle, the ramp rate and maximum value of the magnetic field are investigated. Other published magnet designs used in magnetic refrigeration devices are also evaluated, using a figure of merit based on the properties of the investigated magnetocaloric materials, to learn the properties of the best magnet designs to date. Following this investigation the Halbach cylinder, which is a hollow permanent magnet cylinder with a rotating remanent flux density, is investigated in detail as it forms the basis of many magnet designs used in magnetic refrigeration. Here the optimal dimensions of a Halbach cylinder, as well as analytical calculations of the magnetic field for a Halbach cylinder of infinite length, are presented. Once it has been determined which properties are desirable for a magnet used in magnetic refrigeration the design of a new magnet is described. This is

  7. Boiling Heat Transfer to Halogenated Hydrocarbon Refrigerants

    Science.gov (United States)

    Yoshida, Suguru; Fujita, Yasunobu

    The current state of knowledge on heat transfer to boiling refrigerants (halogenated hydrocarbons) in a pool and flowing inside a horizontal tube is reviewed with an emphasis on information relevant to the design of refrigerant evaporators, and some recommendations are made for future research. The review covers two-phase flow pattern, heat transfer characteristics, correlation of heat transfer coefficient, influence of oil, heat transfer augmentation, boiling from tube-bundle, influence of return bend, burnout heat flux, film boiling, dryout and post-dryout heat transfer.

  8. Dilution refrigeration with multiple mixing chambers

    International Nuclear Information System (INIS)

    Coops, G.M.

    1981-01-01

    A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)

  9. Modular Modeling of a Refrigeration Container

    DEFF Research Database (Denmark)

    Kjær Sørensen, Kresten; Juel Skovrup, Morten; M. Jessen, Lars

    2015-01-01

    This paper presents the modeling of a refrigeration container for use as a reference for energy-optimizing controller design. The model is based on first principles in order to conserve mass and energy, but various assumptions are used to simplify the equations, resulting in a unified model...... for the Star Cool refrigeration unit, the container and the cargo. Comparisons between simulations using the model and measurements from a real container show an average error of less than ±1K on the states important for control....

  10. Online load forecasting for supermarket refrigeration

    DEFF Research Database (Denmark)

    Bacher, Peder; Madsen, Henrik; Nielsen, Henrik Aalborg

    2013-01-01

    This paper presents a study of models for forecasting the load for supermarket refrigeration. The data used for building the forecasting models consists of load measurements, local climate measurements and weather forecasts. The load measurements are from a supermarket located in a village...... in Denmark. Every hour the hourly load for refrigeration for the following 42 hours is forecasted. The forecast models are time adaptive linear time-series models. The dynamic relations between the inputs and the load is modeled by simple transfer functions. The system operates in two regimes: one...

  11. 49 CFR 179.102-17 - Hydrogen chloride, refrigerated liquid.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Hydrogen chloride, refrigerated liquid. 179.102-17...) § 179.102-17 Hydrogen chloride, refrigerated liquid. Each tank car used to transport hydrogen chloride, refrigerated liquid must comply with the following special requirements: (a) The tank car must comply with...

  12. 49 CFR 179.102-1 - Carbon dioxide, refrigerated liquid.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Carbon dioxide, refrigerated liquid. 179.102-1...) § 179.102-1 Carbon dioxide, refrigerated liquid. (a) Tank cars used to transport carbon dioxide, refrigerated liquid must comply with the following special requirements: (1) All plates for tank, manway nozzle...

  13. Literature survey of heat transfer enhancement techniques in refrigeration applications

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

    1994-05-01

    A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

  14. 46 CFR 128.410 - Ship's service refrigeration systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ship's service refrigeration systems. 128.410 Section 128.410 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS... service refrigeration systems. No self-contained unit either for air-conditioning or for refrigerated...

  15. 46 CFR 58.20-20 - Refrigeration piping.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Refrigeration piping. 58.20-20 Section 58.20-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND AUXILIARY MACHINERY AND RELATED SYSTEMS Refrigeration Machinery § 58.20-20 Refrigeration piping. (a) All piping materials...

  16. Face machines

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, D.

    1999-06-01

    The article surveys latest equipment available from the world`s manufacturers of a range of machines for tunnelling. These are grouped under headings: excavators; impact hammers; road headers; and shields and tunnel boring machines. Products of thirty manufacturers are referred to. Addresses and fax numbers of companies are supplied. 5 tabs., 13 photos.

  17. Electric machine

    Science.gov (United States)

    El-Refaie, Ayman Mohamed Fawzi [Niskayuna, NY; Reddy, Patel Bhageerath [Madison, WI

    2012-07-17

    An interior permanent magnet electric machine is disclosed. The interior permanent magnet electric machine comprises a rotor comprising a plurality of radially placed magnets each having a proximal end and a distal end, wherein each magnet comprises a plurality of magnetic segments and at least one magnetic segment towards the distal end comprises a high resistivity magnetic material.

  18. Using solar-powered refrigeration for vaccine storage where other sources of reliable electricity are inadequate or costly.

    Science.gov (United States)

    McCarney, Steve; Robertson, Joanie; Arnaud, Juliette; Lorenson, Kristina; Lloyd, John

    2013-12-09

    Large areas of many developing countries have no grid electricity. This is a serious challenge that threatens the continuity of the vaccine cold chain. The main alternatives to electrically powered refrigerators available for many years--kerosene- and gas-driven refrigerators--are plagued by problems with gas supply interruptions, low efficiency, poor temperature control, and frequent maintenance needs. There are currently no kerosene- or gas-driven refrigerators that qualify under the minimum standards established by the World Health Organization (WHO) Performance, Quality, and Safety (PQS) system. Solar refrigeration was a promising development in the early 1980s, providing an alternative to absorption technology to meet cold chain needs in remote areas. Devices generally had strong laboratory performance data; however, experience in the field over the years has been mixed. Traditional solar refrigerators relied on relatively expensive battery systems, which have demonstrated short lives compared to the refrigerator. There are now alternatives to the battery-based systems and a clear understanding that solar refrigerator systems need to be designed, installed, and maintained by technicians with the necessary knowledge and training. Thus, the technology is now poised to be the refrigeration method of choice for the cold chain in areas with no electricity or extremely unreliable electricity (less than 4h per average day) and sufficient sunlight. This paper highlights some lessons learned with solar-powered refrigeration, and discusses some critical factors for successful introduction of solar units into immunization programs in the future including: •Sustainable financing mechanisms and incentives for health workers and technicians are in place to support long-term maintenance, repair, and replacement parts. •System design is carried out by qualified solar refrigerator professionals taking into account the conditions at installation sites. •Installation and

  19. Stirling-cycle rotating magnetic refrigerators and heat engines for use near room temperature

    International Nuclear Information System (INIS)

    Steyert, W.A.

    1978-01-01

    The application (or removal) of a magnetic field to the ferromagnetic Gd metal near its Curie point (293 K) will produce adiabatic heating (or cooling) of 14 K or isothermal expulsion (or absorption) of 32 kJ of heat per liter of Gd metal. A refrigerator and a heat engine are described for which porous Gd metal forms the rim of a wheel rotating into and out of a magnetic field region. Fluid forced to flow through the porous metal exchanges heat; the field and flow configurations are such that the metal executes a magnetic Stirling cycle allowing a very wide temperature span (many times 14 K) while maintaining the 32-kJ/l capacity. Efficiencies approaching that of Carnot are expected at 1-Hz rotation rates, resulting in 32-kW/l refrigeration or heating capacity

  20. Commercial Refrigeration: Heat Transfer Optimization and Energy Reduction, Measurement and Verification of a Liquid Refrigerant Pump System Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Gaul, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-03-22

    This study describes the test results of a Refrigerant Pump System integrated into a commercial supermarket direct expansion (DX) vapor compression refrigeration system. The Liquid Refrigerant Pump System retrofit (patent-pending; application number 13/964,198) was introduced to NREL in August 2014 by CTA Architects Engineers.

  1. Experimental Investigation of COP Using Hydro Carbon Refrigerant in a Domestic Refrigerator

    Science.gov (United States)

    Peyyala, Anusha; Sudheer, N. V. V. S., Dr

    2017-08-01

    Under the Montreal protocol 1987 researchers worked on the possibility of alternative refrigerants like Hydroflourocarbon’s [HFC’s] and Hydrocarbon’s[HC’s] to replace refrigerants Chloroflourocarbon’s [CFC’s] and Hydrochlorofluorocarbons [HCFC’s] in air-conditioning and cooling systems that are destroying the ozone layer. On October 15, 2016 one hundred and ninety plus countries including India came to an agreement called Kigali Amendment to phase out potent green house gases by 2045 there by preventing 0.5 C rise in global temperature by 2050. Under this agreement India agreed to a timeline to reduce the use of HFC’s by 85% of their baseline by 2045. HFC’s are a family of greenhouse gases that are largely used in refrigerators and air conditioners which have reduced the Ozone Depleting Potential [ODP] but increased the Global Warming Potential [GWP]. Refrigeration and its applications are important in almost all branches of industry, so engineers have to become aware of its principles, uses and limitations. Since the decade there are major changes in the choice of refrigerants due to environmental factors. This issue is on-going and new developments should be developed to decrease the environmental problems. So the aim of this paper is to present the experimental analysis of Coefficient of performance [COP] values using R134a [HFC] & R600a [HC] as Refrigerants in Domestic refrigerator using conventional and nonconventional energy sources. Based on the results, usage of R600a in domestic refrigerators will reduce the ODP and also GWP problems which fulfills the nominal requirements of human beings without any effects.

  2. Thermal analysis of a compound parabolic concentrator for refrigeration applications

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Naghelli; Best, Roberto [Centro de Investigacion en Energia, UNAM, Temixco, Morelos (Mexico)

    2000-07-01

    The refrigeration system designed at the Centro de Investigacion en Energia (CIE), Mexico is able to produce, in optimal conditions, one hundred kilograms per day of ice by means of solar energy. A continuous absorption ammonia-water refrigeration cycle is employed. In its actual state, heat supply to the system is provided through a bank of evacuated tube solar collectors. Their principal difficulties encountered in this system are the indirect heat losses due to the coupling of the falling film generator to the solar heating subsystem that requires a heat transfer gradient and higher collector operating temperatures. Also the high initial cost of the evacuated tube collectors is a barrier for an economical feasible system. Currently, new types of solar collectors are being considered, more efficient and reliable, with a potentially lower cost. This type of collectors known as Compound Parabolic Collectors (CPC) succeed in working at the required temperatures for absorption refrigeration systems. Therefore, a new system is suggested and it is proposed to use a CPC array, where heat losses by the indirect heating system are avoided. In this work a simple method was developed in order to establish the energy balances in a CPC, with a steel tubular receiver without an evacuated glass shell. The receptor's model considers a bidimensional system in stationary state and it supposes a continuous medium. Four nonlinear, simultaneous equations were obtained to predict heat exchange among various components in the system. These equations were utilized in a computer program to analyze the collector performance under various operating conditions. Consequently, the prediction of temperature distribution with respect to position permits to calculate length and arrangement of the CPC for a determined refrigeration application. [Spanish] El sistema de refrigeracion en el Centro de Investigacion en Energia (CIE) Mexico es capaz de producir en condiciones optimas 100

  3. The smallest possible thermal machines and the foundations of thermodynamics

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    In my talk I raise the question on the fundamental limits to the size of thermal machinesrefrigerators, heat pumps and work producing engines - and I will present the smallest possible ones. I will then discuss the issue of a possible complementarity between size and efficiency and show that even the smallest machines could be maximally efficient and I will also present a new point of view over what is work and what do thermal machines actually do. Finally I will present a completely new approach to the foundations of thermodynamics that follows from these results.

  4. Materials for room temperature magnetic refrigeration

    Energy Technology Data Exchange (ETDEWEB)

    Rosendahl Hansen, B.

    2010-07-15

    Magnetic refrigeration is a cooling method, which holds the promise of being cleaner and more efficient than conventional vapor-compression cooling. Much research has been done during the last two decades on various magnetic materials for this purpose and today a number of materials are considered candidates as they fulfill many of the requirements for a magnetic refrigerant. However, no one material stands out and the field is still active with improving the known materials and in the search for a better one. Magnetic cooling is based on the magnetocaloric effect, which causes a magnetic material to change its temperature when a magnetic field is applied or removed. For room temperature cooling, one utilizes that the magnetocaloric effect peaks near magnetic phase transitions and so the materials of interest all have a critical temperature within the range of 250 - 310 K. A magnetic refrigerant should fulfill a number of criteria, among these a large magnetic entropy change, a large adiabatic temperature change, preferably little to no thermal or magnetic hysteresis and the material should have the stability required for long term use. As the temperature range required for room temperature cooling is some 40 - 50 K, the magnetic refrigerant should also be able to cover this temperature span either by exhibiting a very broad peak in magnetocaloric effect or by providing the opportunity for creating a materials series with varying transition temperatures. (Author)

  5. Air Conditioning and Refrigeration Book III.

    Science.gov (United States)

    Eckes, William; Fulkerson, Dan

    Designed to present theory as a functional aspect, this air conditioning and refrigeration curriculum guide is comprised of nine units of instruction. Unit titles include (1) Job Orientation, (2) Applying for a Job, (3) Customer Relations, (4) Business Management, (5) Psychometrics, (6) Residential Heat Loss and Heat Gain, (7) Duct Design and…

  6. Eco-Friendly Alternative Refrigeration Systems

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 10. Eco-Friendly Alternative Refrigeration Systems - Magnetic and ... Author Affiliations. S S Verma1. Deptartment of Physics, Sant Longowal Institute of Engineering and Technology Longowal, District Sangrur, Punjab 148 106, India.

  7. Modeling of In-vehicle Magnetic refrigeration

    DEFF Research Database (Denmark)

    Olsen, Ulrik Lund; Bahl, Christian; Engelbrecht, Kurt

    2012-01-01

    A high-performance magnetic refrigeration device is considered as a potential technology for in-vehicle air conditioners in electric vehicles. The high power consumption of a conventional air conditioner in an electric vehicle has considerable impacts on cruising distance. For this purpose...

  8. Modeling of in-vehicle magnetic refrigeration

    DEFF Research Database (Denmark)

    Olsen, Ulrik Lund; Bahl, Christian R.H.; Engelbrecht, Kurt

    2014-01-01

    A high-performance magnetic refrigeration device is considered as a potential technology for in-vehicle air conditioners in electric vehicles. The high power consumption of a conventional air conditioner in an electric vehicle has considerable impacts on cruising distance. For this purpose...

  9. Dynamic Heat Transfer Model of Refrigerated Foodstuff

    DEFF Research Database (Denmark)

    Cai, Junping; Risum, Jørgen; Thybo, Claus

    2006-01-01

    Commercial refrigerating systems need to be defrosted regularly to maintain a satisfactory performance. When defrosting the evaporator coil, the air temperature inside the display cabinet will increase, and float outside the normal temperature range for a period of time, the question is what happ...

  10. High performance magnetocaloric perovskites for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bahl, Christian R. H.; Velazquez, David; Nielsen, Kaspar K.

    2012-01-01

    We have applied mixed valance manganite perovskites as magnetocaloric materials in a magnetic refrigeration device. Relying on exact control of the composition and a technique to process the materials into single adjoined pieces, we have observed temperature spans above 9 K with two materials...

  11. Detecting Fan Faults in refrigerated Cabinets

    DEFF Research Database (Denmark)

    Thybo, C.; Rasmussen, B.D.; Izadi-Zamanabadi, Roozbeh

    2002-01-01

    Fault detection in supermarket refrigeration systems is an important topic due to both economic and food safety reasons. If faults can be detected and diagnosed before the system drifts outside the specified operational envelope, service costs can be reduced and in extreme cases the costly discar...

  12. Experiments on a modular magnetic refrigeration device

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Jensen, Jesper Buch; Bahl, Christian

    2012-01-01

    An experimental magnetic refrigeration test device has been built at Risø DTU. The device is designed to be modular, and thus all parts of the device can easily be replaced depending on the experiment. This makes the device highly versatile, with the possibility of performing a wide variety...

  13. New possibilities for non-CFC refrigeration

    International Nuclear Information System (INIS)

    Lorentzen, G.; Pettersen, J.

    1992-01-01

    There is a widespread belief that the only viable refrigerants in most applications are new fluorocarbon chemicals. This trend will eventually result in emissions of several hundred thousand tons of new chemicals to the atmosphere each year, involving potential risk of unforeseen environmental effects. A number of other options exist, or may be developed. By using substances which already have a natural role in our ecosystems, some uncertainty related to the critical issue of our future environment can be avoided. By development and practical testing of a laboratory prototype it has been documented that carbon dioxide is a viable refrigerant in automobile air conditioners, completely solving all environmental problems associated with such systems. General use of CO 2 as a refrigerant may provide a number of advantages in the present situation, both from an environmental and practical point of view. It is our considered opinion that the old carbon dioxide offers a key to the complete solution of the environmental problems in many areas of refrigeration usage. 19 refs., 8 figs., 5 tabs

  14. Toward High Performance in Industrial Refrigeration Systems

    OpenAIRE

    Thybo, C.; Izadi-Zamanabadi, Roozbeh; Niemann, H.

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design in industrial refrigeration systems.

  15. Fundamentals of Air Conditioning and Refrigeration.

    Science.gov (United States)

    Clemons, Mark

    This set of instructional materials provides secondary and postsecondary students with a state-of-the-art curriculum for the air conditioning and refrigeration industry that includes the many changes brought by new Environmental Protection Agency (EPA) regulations. Introductory materials explain the use of this publication and provide the…

  16. Mixed Magnetism for Refrigeration and Energy Conversion

    NARCIS (Netherlands)

    Dung, Nguyen H.; Ou, Zhi Qiang; Caron, Luana; Zhang, Lian; Cam Thanh, Dinh T.; Wijs, Gilles A. de; Groot, Rob A. de; Buschow, K.H. Jürgen; Brück, Ekkes

    2011-01-01

    The efficient coupling between lattice degrees of freedom and spin degrees of freedom in magnetic materials can be used for refrigeration and energy conversion. This coupling is enhanced in materials exhibiting the giant magnetocaloric effect. First principle electronic structure calculations on

  17. Air Conditioning and Refrigeration. Book Two.

    Science.gov (United States)

    Wantiez, Gary W.

    This curriculum guide (book II), along with book I, is designed to provide students with the basic skills for an occupation in air conditioning and refrigeration. Six major areas are included, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Electricity (fundamentals of electricity,…

  18. Toward High Performance in Industrial Refrigeration Systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, Roozbeh; Niemann, H.

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design in industr...... in industrial refrigeration systems....

  19. Air Conditioning and Refrigeration Book IV.

    Science.gov (United States)

    Eckes, William; Fulkerson, Dan

    This publication is the concluding text in a four-part curriculum for air conditioning and refrigeration. Materials in Book 4 are designed to complement theoretical and functional elements in Books 1-3. Instructional materials in this publication are written in terms of student performance using measurable objectives. The course includes six…

  20. Air Conditioning and Refrigeration Supplementary Units.

    Science.gov (United States)

    Winston, Del; And Others

    This document contains supplemental materials for special needs high school students intended to facilitate their mainstreaming in regular air conditioning and refrigeration courses. Teacher's materials precede the materials for students and include general notes for the instructor, additional suggestions, two references, a questionnaire on the…

  1. Anaesthetic potency and physiological effects of refrigerated ...

    African Journals Online (AJOL)

    Several in vitro studies have justified the use of thiopentone solutions beyond the period recommended by the manufacturer. We conducted this in vivo study to investigate the anaesthetic potency and physiological effect of refrigerated thiopentone solution. Rabbits in four groups designated A, B, C and D were ...

  2. Air Conditioning and Refrigeration. Book One.

    Science.gov (United States)

    Wantiez, Gary W.

    Designed to provide students with the basic skills for an occupation in air conditioning and refrigeration, this curriculum guide includes seven major areas, each consisting of one or more units of instruction. These areas and their respective units are titled as follows: Orientation (history and development, and job opportunities), Safety…

  3. Towards high performance in industrial refrigeration systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, R.; Niemann, Hans Henrik

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design in industr...... in industrial refrigeration systems....

  4. Readings in Air Conditioning and Refrigeration.

    Science.gov (United States)

    Uberto, Jeffrey A.

    Designed to encourage vocational high school students to read by offering reading materials relevant to their vocational goals, this document contains thirty-seven articles related to air conditioning and refrigeration which have been selected from trade journals, magazines, and newspapers and adapted to the students' reading capabilities. A…

  5. Measurements with a recuperative superfluid stirling refrigerator

    International Nuclear Information System (INIS)

    Watanabe, A.; Swift, G.W.; Brisson, J.G.

    1996-01-01

    A superfluid Stirling refrigerator cooled to 168 mK using a 4.9 % 3 He- 4 He mixture and exhausting its waste heat at 383 mK. Cooling power versus temperature and speed is presented for 4.9%, 17%, and 36% mixtures. At the highest concentration, a dissipation mechanism of unknown origin is observed

  6. Waste Heat Recapture from Supermarket Refrigeration Systems

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Brian A [ORNL

    2011-11-01

    The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

  7. Analysis of refrigerant mal-distribution

    DEFF Research Database (Denmark)

    Kærn, Martin Ryhl; Elmegaard, Brian

    2009-01-01

    to be two straight tubes. The refrigerant maldistribution is then induced to the evaporator by varying the vapor quality at the inlet to each tube and the air-flow across each tube. Finally it is shown that mal-distribution can be compensated by an intelligent distributor, that ensures equal superheat...

  8. ACTIVATED CARBON/REFRIGERANT COMBINATIONS FOR ...

    African Journals Online (AJOL)

    ES Obe

    2001-03-01

    Mar 1, 2001 ... vapour and liquid phases of the refrigerant respectively. In practice, > > , and also it may be assumed that the perfect gas law is obeyed approximately by the vapour. Thus,. (2). Hence by integrating,. This linear relationship between log P and l/T is determined in practice to a first approximation. From the plot ...

  9. The Machine within the Machine

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    Although Virtual Machines are widespread across CERN, you probably won't have heard of them unless you work for an experiment. Virtual machines - known as VMs - allow you to create a separate machine within your own, allowing you to run Linux on your Mac, or Windows on your Linux - whatever combination you need.   Using a CERN Virtual Machine, a Linux analysis software runs on a Macbook. When it comes to LHC data, one of the primary issues collaborations face is the diversity of computing environments among collaborators spread across the world. What if an institute cannot run the analysis software because they use different operating systems? "That's where the CernVM project comes in," says Gerardo Ganis, PH-SFT staff member and leader of the CernVM project. "We were able to respond to experimentalists' concerns by providing a virtual machine package that could be used to run experiment software. This way, no matter what hardware they have ...

  10. Energy consumption of small refrigerators - Information leaflet; Merkblatt Kleinkuehlschrank

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    In this leaflet published by the Swiss Federal Office of Energy (SFOE), the energy consumption of small refrigerators with a capacity of less than 100 litres is reported on. Such small refrigerators are often used in hotel rooms or in campers. It is noted that, in comparison, a typical, 150 litre class A++ domestic refrigerator uses only a fraction of the amount of energy used by such small refrigerators. The results of measurements made according to EN 153 and ISO 15502 norms are discussed. Recommendations are made on the purchase and operation of these small refrigerators.

  11. Étude numérique et expérimentale des transferts couplés de masse et de chaleur dans l’absorbeur d’une machine à absorption ammoniac-eau.

    OpenAIRE

    Triché, Delphine

    2016-01-01

    Ammonia-water absorption chillers are promising both for solar air conditioning and for industry processes. To become competitive compared to electric compression chillers, their efficiency needs to be improved and their cost has to be decreased. This thesis study takes place in this context.The focus is put on the absorber, which is one of the most critical component of absorption chillers in terms of compactness, cost and efficiency. The purpose is to study numerically and experimentally co...

  12. EXERGETIC PERFORMANCE OF A DOMESTIC REFRIGERATOR USING R12 AND ITS ALTERNATIVE REFRIGERANTS

    Directory of Open Access Journals (Sweden)

    BUKOLA O. BOLAJI

    2010-12-01

    Full Text Available Production and use of R12 and other chlorofluorocarbon refrigerants will be prohibited completely all over the world in the year 2010 due to their harmful effects on the earth’s protective ozone layer. Therefore, in this study, the exergetic performance of a domestic refrigerator using two environment-friendly refrigerants (R134a and R152a was investigated and compared with the performance of the system when R12 (an ozone depleting refrigerant was used. The effects of evaporator temperature on the coefficient of performance (COP, exergy flow destruction, exergetic efficiency and efficiency defect in the four major components of the cycle for R12, R134a and R152a were experimentally investigated. The results obtained showed that the average COP of R152a was very close to that of R12 with only 1.4% reduction, while 18.2% reduction was obtained for R134a in comparison with that of R12. The highest average exergetic efficiency of the system (41.5% was obtained using R152a at evaporator temperature of -3.0oC. The overall efficiency defect in the refrigeration cycle working with R152a is consistently better (lower than those of R12 and R134a. Generally, R152a performed better than R134a in terms of COP, exergetic efficiency and efficiency defect as R12 substitute in domestic refrigeration system.

  13. Applicability of ASST-A helium refrigeration system for JLab End Station Refrigerator

    Science.gov (United States)

    Hasan, N.; Knudsen, P.; Ganni, V.

    2017-12-01

    The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab’s four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab’s Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

  14. An innovative ecological hybrid refrigeration cycle for high power refrigeration facility

    Directory of Open Access Journals (Sweden)

    Cyklis Piotr

    2015-09-01

    Full Text Available Searching for new refrigerants is one of the most significant scientific problems in refrigeration. There are ecological refrigerants commonly known: H2O and CO2. H2O and CO2 known as natural refrigerants, but they have problems:a high freezing point of H2O and a low triple point of CO2. These problems can be solved by the application of a hybrid sorption-compression refrigeration cycle. The cycle combines the application possibility of H2O in the high temperature sorption stage and the low temperature application of CO2 in the compression stage. This solution gives significant energy savings in comparison with the two-stage compressor cycle and with the one-stage transcritical CO2 cycle. Besides, the sorption cycle may be powered by low temperature waste heat or renewable heat. This is an original idea of the authors. In the paper an analysis of the possible extension of this solution for high capacity industrial refrigeration is presented. The estimated energy savings as well as TEWI (Total Equivalent Warming Impact index for ecological gains are calculated.

  15. Ecological optimization and coefficient of performance bounds of general refrigerators

    Science.gov (United States)

    Long, Rui; Liu, Wei

    2016-02-01

    An analysis of COP and its bounds at maximum ecological criterion for general refrigerators is conducted. For generality, both the non-isothermal heat transfer processes and the internal dissipations are considered. Under different situations, the COP under the maximum ecological criterion have been studied systematically. And the general upper and lower bounds of the optimal COP have been obtained. Furthermore under maximum ecological criterion, the COP of general endoreversible refrigerators have also been studied. And the COP bounds of different kinds of refrigerators have been analyzed. As actual refrigerators may not operate under the condition of maximum COP or maximum cooling load, but operate under the maximum ecological condition which indicates the best compromise between the refrigeration rate and the loss of refrigeration rate. This paper could provide a practical insight for designing and operating actual refrigerators.

  16. Recent progress in magnetic refrigeration; Jiki reito no kenkyu doko

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T. [National Research Inst. for Metals, Tsukuba, Ibaraki (Japan)

    1997-05-25

    Nearly 20 years have passed since the regular study in magnetic refrigeration commenced. However it has not been put to practical use, because the technology depends largely not only on magnetic materials but also on superconduction magnets, heat switches, and etc. This paper reviews the outline of studies in magnetic refrigeration and their future. The principle of magnetic refrigeration and the merit and demerit are described first under the heading of the special features of magnetic refrigeration. Magnetic materials developed so far are also introduced. Then a Carnot cycle magnetic refrigeration is explained. The study in space satellites by NASA, adiabatic demagnetization refrigerators and etc. are introduced. In the section of magnetic regenerative refrigerators, continuous Carnot active magnetic regenerators (AMR) and Brayton AMR are described. The actual proof study of AMR has been over and the application study has commenced. 36 refs., 14 figs., 2 tabs.

  17. Machine Learning

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Machine learning, which builds on ideas in computer science, statistics, and optimization, focuses on developing algorithms to identify patterns and regularities in data, and using these learned patterns to make predictions on new observations. Boosted by its industrial and commercial applications, the field of machine learning is quickly evolving and expanding. Recent advances have seen great success in the realms of computer vision, natural language processing, and broadly in data science. Many of these techniques have already been applied in particle physics, for instance for particle identification, detector monitoring, and the optimization of computer resources. Modern machine learning approaches, such as deep learning, are only just beginning to be applied to the analysis of High Energy Physics data to approach more and more complex problems. These classes will review the framework behind machine learning and discuss recent developments in the field.

  18. Monel Machining

    Science.gov (United States)

    1983-01-01

    Castle Industries, Inc. is a small machine shop manufacturing replacement plumbing repair parts, such as faucet, tub and ballcock seats. Therese Castley, president of Castle decided to introduce Monel because it offered a chance to improve competitiveness and expand the product line. Before expanding, Castley sought NERAC assistance on Monel technology. NERAC (New England Research Application Center) provided an information package which proved very helpful. The NASA database was included in NERAC's search and yielded a wealth of information on machining Monel.

  19. IEA Annex 26: Advanced Supermarket Refrigeration/Heat Recovery Systems

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, VAN

    2003-05-19

    With increased concern about the impact of refrigerant leakage on global warming, a number of new supermarket refrigeration system configurations requiring significantly less refrigerant charge are being considered. In order to help promote the development of advanced systems and expand the knowledge base for energy-efficient supermarket technology, the International Energy Agency (IEA) established IEA Annex 26 (Advanced Supermarket Refrigeration/Heat Recovery Systems) under the ''IEA Implementing Agreement on Heat Pumping Technologies''. Annex 26 focuses on demonstrating and documenting the energy saving and environmental benefits of advanced systems design for food refrigeration and space heating and cooling for supermarkets. Advanced in this context means systems that use less energy, require less refrigerant and produce lower refrigerant emissions. Stated another way, the goal is to identify supermarket refrigeration and HVAC technology options that reduce the total equivalent warming impact (TEWI) of supermarkets by reducing both system energy use (increasing efficiency) and reducing total refrigerant charge. The Annex has five participating countries: Canada, Denmark, Sweden, the United Kingdom, and the United States. The working program of the Annex has involved analytical and experimental investigation of several candidate system design approaches to determine their potential to reduce refrigerant usage and energy consumption. Advanced refrigeration system types investigated include the following: distributed compressor systems--small parallel compressor racks are located in close proximity to the food display cases they serve thus significantly shortening the connecting refrigerant line lengths; secondary loop systems--one or more central chillers are used to refrigerate a secondary coolant (e.g. brine, ice slurry, or CO2) that is pumped to the food display cases on the sales floor; self-contained display cases--each food display case

  20. The greatest solar refrigeration plant of Switzerland. Holistic saving of CO{sub 2} at a private bank; Die groesste solare Kaelteanlage der Schweiz. Ganzheitliche CO{sub 2}-Einsparung bei einer Privatbank

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Wolfgang

    2011-07-01

    Since June 2008, the Swiss private bank Pictet and Cie. (Geneva, Switzerland) operates the largest solar refrigerant plant of Switzerland. The solar generated heat is used all over the year for heating up of drinking water, seasonally for room air conditioning and in the summer for driving of three absorption refrigerators with a refrigerating capacity of totally 210 kW. This is sufficient in order to keep the office space of nearly 4,000 m{sup 2} at a moderate temperature by means of cooling ceilings.

  1. Theoretical study on a novel dual-nozzle ejector enhanced refrigeration cycle for household refrigerator-freezers

    International Nuclear Information System (INIS)

    Zhou, Mengliu; Wang, Xiao; Yu, Jianlin

    2013-01-01

    Highlights: • A novel dual-nozzle ejector enhanced refrigeration cycle is proposed. • The novel cycle is evaluated by using the developed mathematical model. • The results show the performances of the novel cycle could be significantly improved. • The novel cycle shows its promise in household refrigerator-freezers applications. - Abstract: In this study, a novel dual-nozzle ejector enhanced refrigeration cycle is presented for dual evaporator household refrigerator-freezers. The proposed ejector equipped with two nozzles can efficiently recover the expansion work from cycle throttling processes and enhance cycle performances. The performances of the novel cycle are evaluated by using the developed mathematical model, and then compared with that of the conventional ejector enhanced refrigeration cycle and basic vapor-compression refrigeration cycle. The simulation results show that for the given operating conditions, the coefficient of performance (COP) of the novel cycle using refrigerant R134a is improved by 22.9–50.8% compared with that of the basic vapor-compression refrigeration cycle, and the COP improvement is 10.5–30.8% larger than that of the conventional ejector enhanced refrigeration cycle. The further simulation results of the novel cycle using refrigerant R600a indicate that the cycle COP and volumetric refrigeration capacity could be significantly improved

  2. Evaluation of the introduction of cogeneration for refrigeration in the fisheries sector of the Amazon; Avaliacao da introducao da cogeracao para refrigeracao no setor pesqueiro do Amazonas

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Ricardo Wilson Aguiar da [Universidade Estadual do Amazonas (UEA), Manaus (Brazil)], e-mail: rcruz@uea.edu.br; Nebra, Silvia Azucena [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Faculdade de Engenharia Mecanica], e-mail: sanebra@fem.unicamp.br; Cartaxo, Elizabeth Ferreira [Universidade Federal do Amazonas (UFAM), Manaus, AM (Brazil)], e-mail: ecartaxo@ufam.edu.br

    2004-07-01

    This work analyses the opportunity to introduce cogeneration for the production of aquammonia absorption refrigeration in the autonomous Amazons State power system, by one hand as a means to improve its efficiency and by another, solve the deficiency the State has to store its fish-ing production. (author)

  3. Comparison of diverse climatic sources for the simulation of facilities of solar refrigeration; Comparacion de diversas fuentes climaticas para la simulacion de instalaciones de refrigeracion solar

    Energy Technology Data Exchange (ETDEWEB)

    Bujedo, L. A.; Vicente, J.; Torre, C. de; Macia, A.; Rodriguez, J.

    2008-07-01

    With the present work they are sought to analyze the results based on simulations hourly of an installation of solar refrigeration by absorption, subjected to different sources of weather data. For it, the authors have modelled one of the facilities of the Technology Centre CARTIF located in Boecillo (Valladolid), under the environment TRNSYS. (Author)

  4. Analysis of Refrigeration Cycle Performance with an Ejector

    Directory of Open Access Journals (Sweden)

    Wani J. R.

    2016-01-01

    Full Text Available A conventional refrigeration cycle uses expansion device between the condenser and the evaporator which has losses during the expansion process. A refrigeration cycle with ejector is a promising modification to improve the performance of conventional refrigeration cycle. The ejector is used to recover some of the available work so that the compressor suction pressure increases. To investigate the enhancement a model with R134a refrigerant was developed. To solve the set of equations and simulate the cycle performance a subroutine was written on engineering equation solver (EES environment. At specific conditions, the refrigerant properties are obtained from EES. At the design conditions the ejector refrigeration cycle achieved 5.141 COP compared to 4.609 COP of the conventional refrigeration cycle. This means that ejector refrigeration cycle offers better COP with 10.35% improvement compared to conventional refrigeration cycle. Parametric analysis of ejector refrigeration cycle indicated that COP was influenced significantly by evaporator and condenser temperatures, entrainment ratio and diffuser efficiency.

  5. Modeling and calculation of open carbon dioxide refrigeration system

    International Nuclear Information System (INIS)

    Cai, Yufei; Zhu, Chunling; Jiang, Yanlong; Shi, Hong

    2015-01-01

    Highlights: • A model of open refrigeration system is developed. • The state of CO 2 has great effect on Refrigeration capacity loss by heat transfer. • Refrigeration capacity loss by remaining CO 2 has little relation to the state of CO 2 . • Calculation results are in agreement with the test results. - Abstract: Based on the analysis of the properties of carbon dioxide, an open carbon dioxide refrigeration system is proposed, which is responsible for the situation without external electricity unit. A model of open refrigeration system is developed, and the relationship between the storage environment of carbon dioxide and refrigeration capacity is conducted. Meanwhile, a test platform is developed to simulation the performance of the open carbon dioxide refrigeration system. By comparing the theoretical calculations and the experimental results, several conclusions are obtained as follows: refrigeration capacity loss by heat transfer in supercritical state is much more than that in two-phase region and the refrigeration capacity loss by remaining carbon dioxide has little relation to the state of carbon dioxide. The results will be helpful to the use of open carbon dioxide refrigeration

  6. Performance Analysis of Multipurpose Refrigeration System (MRS on Fishing Vessel

    Directory of Open Access Journals (Sweden)

    Ust Y.

    2016-04-01

    Full Text Available The use of efficient refrigerator/freezers helps considerably to reduce the amount of the emitted greenhouse gas. A two-circuit refrigerator-freezer cycle (RF reveals a higher energy saving potential than a conventional cycle with a single loop of serial evaporators, owing to pressure drop in each evaporator during refrigeration operation and low compression ratio. Therefore, several industrial applications and fish storage systems have been utilized by using multipurpose refrigeration cycle. That is why a theoretical performance analysis based on the exergetic performance coefficient, coefficient of performance (COP, exergy efficiency and exergy destruction ratio criteria, has been carried out for a multipurpose refrigeration system by using different refrigerants in serial and parallel operation conditions. The exergetic performance coefficient criterion is defined as the ratio of exergy output to the total exergy destruction rate (or loss rate of availability. According to the results of the study, the refrigerant R32 shows the best performance in terms of exergetic performance coefficient, COP, exergy efficiency, and exergy destruction ratio from among the other refrigerants (R1234yf, R1234ze, R404A, R407C, R410A, R143A and R502. The effects of the condenser, freezer-evaporator and refrigerator-evaporator temperatures on the exergetic performance coefficient, COP, exergy efficiency and exergy destruction ratios have been fully analyzed for the refrigerant R32.

  7. An optimized magnet for magnetic refrigeration

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian Robert Haffenden; Smith, Anders

    2010-01-01

    A magnet designed for use in a magnetic refrigeration device is presented. The magnet is designed by applying two general schemes for improving a magnet design to a concentric Halbach cylinder magnet design and dimensioning and segmenting this design in an optimum way followed by the construction...... of the actual magnet. The final design generates a peak value of 1.24 T, an average flux density of 0.9 T in a volume of 2 L using only 7.3 L of magnet, and has an average low flux density of 0.08 T also in a 2 L volume. The working point of all the permanent magnet blocks in the design is very close...... to the maximum energy density. The final design is characterized in terms of a performance parameter, and it is shown that it is one of the best performing magnet designs published for magnetic refrigeration....

  8. Hybrid control of the distributed refrigeration system

    DEFF Research Database (Denmark)

    Chen, L.; Wisniewski, R.

    2010-01-01

    The supermarket refrigeration system typically has a distributed control structure, which neglects interactions between its subsystems. These interactions from time to time lead to a synchronization operation of the display-cases which causes an inferior control performance and increased energy...... consumption. The paper focuses on synchronization dynamics of the refrigeration system modeled as a piecewise-affine switched system. System behaviors are analyzed using chaos theory. The synchronization phenomenon is interpreted as a stable low-period orbit; if the system has a high-order periodic orbit...... or a chaotic behavior, the system is considered away from the synchronization. Therefore, the paper proposes a concept that the system may be de-synchronized by making it chaotic. A de-synchronization scheme is developed. It includes a synchronization-early-monitoring detector by calculating the maximum...

  9. Synchronization Analysis of the Supermarket Refrigeration System

    DEFF Research Database (Denmark)

    Wisniewski, Rafal; Chen, Liang; Larsen, Lars Finn Sloth

    2009-01-01

    consumption. The paper focuses on synchronization dynamics of the refrigeration system modeled as a piecewiseaffine switched system. Stability analysis is performed bygluing the subsystems and polyhedra together to form a single dynamical system defined on a coherent state space. Then, system behavior......The supermarket refrigeration system typically has a distributed control structure, which neglects interactions between its subsystems. These interactions from time to time lead to a synchronization operation of the display-cases which causes an inferior control performance and increased energy...... is analyzed using the bifurcation and chaos theory. It is demonstrated that the system can have a complex chaotic behavior, which is far from the synchronization. This shows that making the system chaotic is a good choice for a de-synchronization strategy. The positive maximum Lyapunov exponent is usually...

  10. Energy analysis of a supermarket refrigeration system

    DEFF Research Database (Denmark)

    Jensen, Jakob Munch; Jakobsen, Arne; Rasmussen, Bjarne D.

    1999-01-01

    From 1995 to 1998, an energy test method for supermarket refrigeration systems was developed in a project financed by the Danish Energy Agency. The purpose of the energy test method is to provide the means for evaluating the energy efficiency of these systems. The test method requires measurements...... of air temperatures and energy consumption to be carried out on the selected supermarket refrigeration system. In addition to the measurements required by the method, more measurements of individual energy consumptions have been carried in the case described in this paper. The purpose of the additional...... systems and therefore the experience with its application is limited. In the future, the energy test method may be used for evaluation of the efficiency of a new system or the improvement in efficiency when optimising an existing system....

  11. Modelling refrigerant distribution in minichannel evaporators

    DEFF Research Database (Denmark)

    Brix, Wiebke

    This thesis is concerned with numerical modelling of flow distribution in a minichannel evaporator for air-conditioning. The study investigates the impact of non-uniform airflow and non-uniform distribution of the liquid and vapour phases in the inlet manifold on the refrigerant mass flow...... in the numerical experiments using the test case evaporator. The results show that the reduction in cooling capacity due to non-uniform airflow and non-uniform liquid and vapour distribution is generally larger when using R134a than when using CO2 as refrigerant. Comparing the capacity reductions with reductions...... of the liquid and vapour in the inlet manifold. Combining non-uniform airflow and non-uniform liquid and vapour distribution shows that a non-uniform airflow distribution to some degree can be compensated by a suitable liquid and vapour distribution. Controlling the superheat out of the individual channels...

  12. Materials for Room Temperature Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Hansen, Britt Rosendahl

    to change its temperature when a magnetic field is applied or removed. For room temperature cooling, one utilizes that the magnetocaloric effect peaks near magnetic phase transitions and so the materials of interest all have a critical temperature within the range of 250 – 310 K. A magnetic refrigerant...... should fulfill a number of criteria, among these a large magnetic entropy change, a large adiabatic temperature change, preferably little to no thermal or magnetic hysteresis and the material should have the stability required for long term use. As the temperature range required for room temperature......Magnetic refrigeration is a cooling method, which holds the promise of being cleaner and more efficient than conventional vapor-compression cooling. Much research has been done during the last two decades on various magnetic materials for this purpose and today a number of materials are considered...

  13. Thermal Losses Effect on the Performance of an Intermittent Solar Refrigeration Cycle for Generation Phase

    International Nuclear Information System (INIS)

    Boukhchana, Yasmina; Fellah, Ali; Ben Brahim, Ammar

    2009-01-01

    In this contribution, a study of the thermal losses effect undergone by the different parts of an intermittent absorption solar refrigeration cycle using the Ammonia/Water mixture is presented. After having shown the interest of the intermittent cycles through the discussion of the problem of the adaptation of these cycles to solar energy, mass and thermal assessments for each compartment of the installation were established for the two cases without and with thermal losses. The resulting differential equations system is solved numerically. The theoretical results obtained concern the temperature variations, the vapor flow as well as the compositions of the rich and the poor solutions

  14. Silicon spectrometer with a Peltier refrigerator

    International Nuclear Information System (INIS)

    Belcarz, E.; Chwaszczewska, J.; Hahn, G.; Nowicki, W.; Sawicka, B.; Skoczek, K.; Slapa, M.; Szymczak, M.

    1974-01-01

    This paper describes a spectrometer with a Si(Li) detector cooled by a Peltier refrigerator. The spectrometer is able to analyse samples of practically all most frequently encountered emitters of alpha, beta and low energy gamma radiation. The energy resolution were about 1.3-1.5 keV for 14 keV gamma radiation. The system can also operate in field conditions in the fluorescence analysis. (author)

  15. Cryo-refrigerators for CNS applications

    International Nuclear Information System (INIS)

    Clausen, J.; Lesser, J.; Sebastianutto, R.

    2001-01-01

    Cryo-refrigeration plants for cold neutron sources belong to the field of auxiliary plants or utility facilities of the reactor. In general, they are classified as non-nuclear and serve to dissipate the heat generated in the liquid hydrogen or deuterium from moderating the neutrons of the cold neutron source. Cryo-refrigeration plants for the temperature range of 20 K supply either refrigeration at constant temperature by means of evaporating the cryogenic coolant (usually hydrogen) or, as usual with cold sources, in a specific temperature range by means of warming-up the cryogenic coolant (usually helium) in the moderator or heat exchanger (condensation or subcooling of the deuterium). The operator's requirements to a refrigeration plant are, first of all, that the plant adjusts itself - at low-maintenance or maintenance-free - to the various operation modes at best thermodynamic efficiencies and that it offers as much operating convenience and operating safety as possible. Additional requirements are short times for cool-down, capacity adjustment, stand-by operation in order to avoid poisoning of the cold source and further operational requirements. However, these requirements are limited by mechanics, thermodynamics and financial means. For this reason, for each application a technical solution must be found which is optimally adapted to the competing requirements and which is based on a standard product of the manufacturer, if possible. The operator's different requirements have to be taken in account with regard to the design of the plant and choice of the components; economic aspects in addition also have to be considered. Wherever possible, proven standard components should be used. (orig.)

  16. Machine Protection

    CERN Document Server

    Zerlauth, Markus; Wenninger, Jörg

    2012-01-01

    The present architecture of the machine protection system is being recalled and the performance of the associated systems during the 2011 run will be briefly summarized. An analysis of the causes of beam dumps as well as an assessment of the dependability of the machine protection systems (MPS) itself is being presented. Emphasis will be given to events that risked exposing parts of the machine to damage. Further improvements and mitigations of potential holes in the protection systems will be evaluated along with their impact on the 2012 run. The role of rMPP during the various operational phases (commissioning, intensity ramp up, MDs...) will be discussed along with a proposal for the intensity ramp up for the start of beam operation in 2012.

  17. Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool

    Energy Technology Data Exchange (ETDEWEB)

    Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

    2012-01-01

    Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

  18. Laser-refrigeration of rare-earth-doped nanocrystals in water

    Science.gov (United States)

    Roder, Paden B.; Smith, Bennett; Zhou, Xuezhe; Crane, Matthew J.; Pauzauskie, Peter J.

    2015-03-01

    Single-beam laser-tweezers have been demonstrated over the past several decades to confine nanometer-scale particles in three dimensions with sufficient sensitivity to measure the spring constants of individual biological macromolecules including DNA. Large laser-irradiance values (on the order of MW/cm2) commonly are used to generate laser traps which can lead to significant laser-heating within the 3D optical potential well. To date, laser-refrigeration of particles within an aqueous medium has not been reported stemming primarily from the large near-infrared (NIR) optical absorption coefficient of liquid water (0.2 cm-1 at lambda = 1020nm). In this paper we will detail the methods on how single-beam laser-traps can be used to induce and quantify the refrigeration of optically trapped nanocrystals in an aqueous medium. Analysis of the Brownian dynamics of individual nanocrystals via forward light scattering provides a way to determine both a relative and absolute measurement of particle's temperature. Signal analysis considerations to interpreting Brownian motion data of trapped particles in nonisothermal aqueous environments, or so-called hot Brownian motion, are detailed. Applications of these methods to determining local laser-refrigeration of laser trapped nanoparticles in water show promise at realizing the first observation of particles undergoing cold Brownian motion.

  19. Fault detection and diagnosis for refrigerator from compressor sensor

    Science.gov (United States)

    Keres, Stephen L.; Gomes, Alberto Regio; Litch, Andrew D.

    2016-12-06

    A refrigerator, a sealed refrigerant system, and method are provided where the refrigerator includes at least a refrigerated compartment and a sealed refrigerant system including an evaporator, a compressor, a condenser, a controller, an evaporator fan, and a condenser fan. The method includes monitoring a frequency of the compressor, and identifying a fault condition in the at least one component of the refrigerant sealed system in response to the compressor frequency. The method may further comprise calculating a compressor frequency rate based upon the rate of change of the compressor frequency, wherein a fault in the condenser fan is identified if the compressor frequency rate is positive and exceeds a condenser fan fault threshold rate, and wherein a fault in the evaporator fan is identified if the compressor frequency rate is negative and exceeds an evaporator fan fault threshold rate.

  20. Simulated performance of biomass gasification based combined power and refrigeration plant for community scale application

    Energy Technology Data Exchange (ETDEWEB)

    Chattopadhyay, S., E-mail: suman.mech09@gmail.com [Department of Mechanical Engineering, NIT, Agarpara, Kolkata – 700109, West Bengal (India); Mondal, P., E-mail: mondal.pradip87@gmail.com; Ghosh, S., E-mail: sudipghosh.becollege@gmail.com [Department of Mechanical Engineering, IIEST, Shibpur, Howrah – 711103, West Bengal (India)

    2016-07-12

    Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR) cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (r{sub p}) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio

  1. Study of a new solar adsorption refrigerator powered by a parabolic trough collector

    Energy Technology Data Exchange (ETDEWEB)

    El Fadar, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco); Mimet, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco)], E-mail: mimet@fst.ac.ma; Azzabakh, A. [Energetic Laboratory, Sciences Faculty, BP 2121, 93000 Tetouan, Abdelmalek Essaadi University (Morocco); Perez-Garcia, M. [Dpto. de Fisica Aplicada - Universidad de Almeria (Spain); Castaing, J. [Laboratoire Thermique, Energetique et Procedes (LaTEP), Avenue de l' Universite, BP 1155, 64013 Pau Cedex (France)

    2009-04-15

    This paper presents the study of solar adsorption cooling machine, where the reactor is heated by a parabolic trough collector (PTC) and is coupled with a heat pipe (HP). This reactor contains a porous medium constituted of activated carbon, reacting by adsorption with ammonia. We have developed a model, based on the equilibrium equations of the refrigerant, adsorption isotherms, heat and mass transfer within the adsorbent bed and energy balance in the hybrid system components. From real climatic data, the model computes the performances of the machine. In comparison with other systems powered by flat plate or evacuated tube collectors, the predicted results, have illustrated the ability of the proposed system to achieve a high performance due to high efficiency of PTC, and high flux density of heat pipe.

  2. Refrigeration arrangement and methods for reducing charge migration

    Science.gov (United States)

    Litch, Andrew D.; Wu, Guolian

    2017-04-11

    A refrigerator appliance including a refrigerant circuit between a condenser, an evaporator, and a compressor that includes two conduits and pressure reducing devices arranged in parallel between the evaporator and the condenser. The appliance also includes a valve system to direct refrigerant through one, both or none of the conduits and pressure reducing devices, and a heat exchanging member in thermal contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system.

  3. Machine rates for selected forest harvesting machines

    Science.gov (United States)

    R.W. Brinker; J. Kinard; Robert Rummer; B. Lanford

    2002-01-01

    Very little new literature has been published on the subject of machine rates and machine cost analysis since 1989 when the Alabama Agricultural Experiment Station Circular 296, Machine Rates for Selected Forest Harvesting Machines, was originally published. Many machines discussed in the original publication have undergone substantial changes in various aspects, not...

  4. Representational Machines

    DEFF Research Database (Denmark)

    to the enterprises of the medium. This is the subject of Representational Machines: How photography enlists the workings of institutional technologies in search of establishing new iconic and social spaces. Together, the contributions to this edited volume span historical epochs, social environments, technological...

  5. Precision Machining

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    Panasonic's new laser printer using Precitech's machine tools described by Davis in this issue. The need to use natural and synthetic diamonds, a development that uses Bridgman's inven- tion of high pressure presses of over 40 kbars is now surpassed by diamond deposition tech- niques highlighted by Erik Bauer and his ...

  6. Machine testning

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with a laboratory exercise of 3 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercise includes a series of tests carried out by the student on a conventional and a numerically controled lathe, respectively. This document...

  7. Refrigeration processes a practical handbook on the physical properties of refrigerants and their applications

    CERN Document Server

    Meacock, H M

    1979-01-01

    A comprehensive applications-oriented treatment of the subject in two parts. The first part forms a useful introduction to basic principles dealing with the definitions of the physical properties and outlines the method of their calculation. The second part is devoted to calculated data on a range of refrigerants by means of extensive tables and diagrams. The treatment takes the form of a data sheet, one for each of about thirty refrigerants; this data sheet gives the essential information from which close approximations of pressure, temperature, volume and enthalpy can be made for any predict

  8. Refrigeration Playbook. Heat Reclaim; Optimizing Heat Rejection and Refrigeration Heat Reclaim for Supermarket Energy Conservation

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Chuck [CTA Architects Engineers, Boise, ID (United States); Nelson, Eric [CTA Architects Engineers, Boise, ID (United States); Armer, James [CTA Architects Engineers, Boise, ID (United States); Johnson, Tim [CTA Architects Engineers, Boise, ID (United States); Hirsch, Adam [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Doebber, Ian [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-03-01

    The purpose of this playbook and accompanying spreadsheets is to generalize the detailed CBP analysis and to put tools in the hands of experienced refrigeration designers to evaluate multiple applications of refrigeration waste heat reclaim across the United States. Supermarkets with large portfolios of similar buildings can use these tools to assess the impact of large-scale implementation of heat reclaim systems. In addition, the playbook provides best practices for implementing heat reclaim systems to achieve the best long-term performance possible. It includes guidance on operations and maintenance as well as measurement and verification.

  9. Model based control of refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Sloth Larsen, L.F.

    2005-11-15

    The subject for this Ph.D. thesis is model based control of refrigeration systems. Model based control covers a variety of different types of controls, that incorporates mathematical models. In this thesis the main subject therefore has been restricted to deal with system optimizing control. The optimizing control is divided into two layers, where the system oriented top layers deals with set-point optimizing control and the lower layer deals with dynamical optimizing control in the subsystems. The thesis has two main contributions, i.e. a novel approach for set-point optimization and a novel approach for desynchronization based on dynamical optimization. The focus in the development of the proposed set-point optimizing control has been on deriving a simple and general method, that with ease can be applied on various compositions of the same class of systems, such as refrigeration systems. The method is based on a set of parameter depended static equations describing the considered process. By adapting the parameters to the given process, predict the steady state and computing a steady state gradient of the cost function, the process can be driven continuously towards zero gradient, i.e. the optimum (if the cost function is convex). The method furthermore deals with system constrains by introducing barrier functions, hereby the best possible performance taking the given constrains in to account can be obtained, e.g. under extreme operational conditions. The proposed method has been applied on a test refrigeration system, placed at Aalborg University, for minimization of the energy consumption. Here it was proved that by using general static parameter depended system equations it was possible drive the set-points close to the optimum and thus reduce the power consumption with up to 20%. In the dynamical optimizing layer the idea is to optimize the operation of the subsystem or the groupings of subsystems, that limits the obtainable system performance. In systems

  10. Contribution to magnetic refrigeration study at liquid helium study

    International Nuclear Information System (INIS)

    Lacaze, A.

    1985-10-01

    An experimental prototype of magnetic refrigerator operates, following a Carnot cycle, with gallium gadolinium garnet, from liquid helium at 4.2 0 K. Analysis of the cyle and heat exchanges allowed to improve performance up to get more than 50% of Carnot yield at 1.8 0 K and nearly 80% at 2.1 0 K. Operation conditions of a regenerator refrigerator between 4 and 20 0 K are studied. The association of a magnetic refrigerator and a gas refrigerator is analyzed. Among different ways to realize the magnetic stage, an active regenerator cycle is chosen. An experimental device is described [fr

  11. Phase and viscosity behaviour of refrigerant-lubricant mixtures

    DEFF Research Database (Denmark)

    Cisneros, Sergio; Garcia, J.; Fernandez, J.

    2005-01-01

    The understanding of thermophysical properties and phase behaviour of refrigerant-lubricant oil mixtures is highly important for the optimal design of refrigeration and air-conditioning systems. Refrigerant lubricant mixtures, which are likely to have strong asymmetry, can show complex phase...... behaviour such as closed miscibility gaps, open miscibility gaps, liquid-liquid-vapour equilibrium, and even barotropic phenomena (density inversions). In fact, the type of phase behaviour that refrigerant-lubricant mixtures may show is linked to the transition between different types of phase diagrams...

  12. Power Consumption in Refrigeration Systems - Modeling for Optimization

    DEFF Research Database (Denmark)

    Hovgaard, Tobias Gybel; Larsen, Lars F. S.; Skovrup, Morten Juel

    2011-01-01

    Refrigeration systems consume a substantial amount of energy. Taking for instance supermarket refrigeration systems as an example they can account for up to 50−80% of the total energy consumption in the supermarket. Due to the thermal capacity made up by the refrigerated goods in the system...... there is a possibility for optimizing the power consumption by utilizing load shifting strategies. This paper describes the dynamics and the modeling of a vapor compression refrigeration system needed for sufficiently realistic estimation of the power consumption and its minimization. This leads to a non-convex function...

  13. Reasearch and Evaluation of Electromagnetic Fields of Refrigerators

    Directory of Open Access Journals (Sweden)

    Pranas Baltrėnas

    2013-12-01

    Full Text Available The use of refrigerators causes the occurence of electromagnetic fields that are invisible and intangible, which therefore makes difficulties in protecting ourselves from them. A refrigerator is an irreplaceable item in domestic household and thus can be hardly ignored by a modern way of human life. In order to preserve the characteristics of products, the refrigerator must operate continuously (24 hrs a day, regardless of the time of the year. This results in a huge increase in electricity consumption, which leads to energy consumption related pollution of the environment emitting CO2 gas. On these grounds, it is necessary to assess electromagnetic fields created by the refrigerator. Studies on electromagnetic fields produced by refrigerators were conducted in domestic premises where people spent a significant part of the day. For comparison purposes, five different power refrigerators were chosen (1 – 0.20 kW; 2 – 0.25 kW; 3 – 0.30 kW; 4 – 0.35 kW; 5 – 0.40 kW. The obtained results, according to the parameters of their electromagnetic fields, were presented in graphs and charts and showed that the values of electric and magnetic intensity of refrigerators depended on the distance and the power of the refrigerator. The conducted research also disclosed that none of tested refrigerators exceeded the permissible limits of electromagnetic fields.Article in Lithuanian

  14. Polyhalogenated hydrocarbon refrigerants and refrigerant oils colored with fluorescent dyes and method for their use as leak detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, M.

    1988-07-19

    A leak detectable refrigeration composition is described comprising: (A) a refrigeration liquid selection from the group consisting of: (1) a polyhalogenated hydrocarbon refrigerant; (2) a refrigeration oil selected from the group consisting of naphthenic oils, paraffinic oils, alkylated benzenes, silicones, polyglycols, diesters or triesters of dicarboxylic or tricarboxylic acids, and polyalkyl silicate oils, and (3) a mixture of A(1) and A(2), and (B) a fluorescent dye compound or composition comprising the dye selected from the group consisting of: (1) a fluorescent dye selected from the group consisting of perylene, naphthoxanthene, monocyclic aromatic compounds having an organometallic compound, (2) a solution of fluorescent dye in a solvent, and (3) a mixture of B(1) and B(2). The fluorescent dye compound or composition is soluble in the refrigeration liquid. The concentration of the dye being at least 0.001 grams per 100 grams of the refrigeration liquid.

  15. Absorption chillers integration in a combined heat and power plant

    Energy Technology Data Exchange (ETDEWEB)

    Bruno, J. C.; Fernandez, F.; Castells, F. [Barcelona Univ., Tarragona (Spain). Dept. d`Enginyeria Quimica i Bioqumica

    1996-11-01

    Inclusion of an absorption cycle within a combined heat and power plant (CHP) was evaluated. To determine the most suitable configuration of the energy network generation system and absorption chiller, a simulation and optimization model was constructed. To validate the optimization model, a case study using actual data from existing operating plants has been used. In the case described the cooling facilities from the absorption cycle were used to lower the inlet temperature to the compressor of the gas turbine to improve the overall plant efficiency. Waste steam from the steam network was used in the generator of the absorption chiller. A reduction in steam wastes, and an improvement in overall plant efficiency was observed. A simulation model of a single effect absorption chiller, using water-lithium bromide as the working fluid pair, was used to validate the methodology. Results showed that the benefits of integrating the absorption refrigeration cycle (ARC) depends directly on the refrigeration demand, and on the benefit produced by the waste steam recovered. The increase in power generation, allowing a reduction in primary energy consumption, showed a slight economic advantage over the conventional compression cycle. 13 refs., 7. tabs., 6 figs.

  16. Cryogenic Heat Load and Refrigeration Capacity Management at the Large Hadron Collider (LHC)

    CERN Document Server

    Claudet, S; Serio, L; Tavian, L; Van Weelderen, R; Wagner, U

    2009-01-01

    The Large Hadron Collider (LHC) is a 26.7 km high-energy proton and ion collider based on several thousand high-field superconducting magnets operating in superfluid helium below 2 K, now under commissioning at CERN. After a decade of development of the key technologies, the project was approved for construction in 1994 and the industrial procurement for the cryogenic system launched in 1997, concurrently with the completion of the R&D program. This imposed to base the sizing of the refrigeration plants on estimated and partially measured values of static and dynamic heat loads, with adequate uncertainty and overcapacity coefficients to cope with unknowns in machine configuration and in physical processes at work. With the cryogenic commissioning of the complete machine, full-scale static heat loads could be measured, thus confirming the correctness of the estimates and the validity of the approach, and safeguarding excess refrigeration capacity for absorbing the beam-induced dynamic loads. The metho...

  17. 77 FR 76825 - Energy Conservation Program: Certification of Commercial and Industrial HVAC, Refrigeration and...

    Science.gov (United States)

    2012-12-31

    ... Energy Conservation Program: Certification of Commercial and Industrial HVAC, Refrigeration and Water... provisions for commercial refrigeration equipment; commercial heating, ventilating, air-conditioning (HVAC..., the Department extended the compliance date for certification of commercial refrigeration equipment...

  18. Lean flammability limit as a fundamental refrigerant property: Phase 3. Final technical report, February 1997--February 1998

    Energy Technology Data Exchange (ETDEWEB)

    Grosshandler, W.; Donnelly, M.; Womeldorf, C.

    1998-08-01

    Alternative refrigerants are being developed by industry to prevent the further destruction of stratospheric ozone by chlorofluorocarbons (CFCs), which had been the working fluids of choice for many air-conditioning and refrigeration machines. Hydrofluorocarbons (HFCs) are one class of compounds that are being pursued as replacements because their ozone depletion potential is zero. In general, the exchange of fluorine atoms on an HFC molecule with hydrogen atoms decreases its atmospheric lifetime, and it may also increase the efficiency of the working fluid. Both of these effects are highly desirable from environmental considerations since they act to mitigate global warming. Unfortunately, more hydrogen on a HFC is usually associated with an increase in flammability. An accepted method for determining the flammability limits of gaseous fuels is ASTM Standard E 681. The minimum and maximum concentrations of the fuel in air for flame propagation are based upon the observed ignition and growth of a flame in a vessel filled with a quiescent fuel/air mixture. a Clear distinction is sought between a non-propagating flicker and a flame which has enough horizontal propagation to be hazardous. This report reviews the past work done on premixed, counter-flowing flames, describes the current counter-flow burner facility and operating procedures, presents the experimental results with the analysis that yields the above flammability limits, and recommends further activities that could lead to a science-based methodology for assessing the risk of fire from refrigeration machine working fluids. 30 figs.

  19. Next Generation Refrigeration Lubricants for Low Global Warming Potential/Low Ozone Depleting Refrigeration and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hessell, Edward Thomas [Chemtura Corporation, Middlebury, CT (United States)

    2013-12-31

    The goal of this project is to develop and test new synthetic lubricants that possess high compatibility with new low ozone depleting (LOD) and low global warming potential (LGWP) refrigerants and offer improved lubricity and wear protection over current lubricant technologies. The improved compatibility of the lubricants with the refrigerants, along with improved lubricating properties, will resulted in lower energy consumption and longer service life of the refrigeration systems used in residential, commercial and industrial heating, ventilating and air-conditioning (HVAC) and refrigeration equipment.

  20. Machine Learning

    Science.gov (United States)

    Hoffmann, Achim; Mahidadia, Ashesh

    The purpose of this chapter is to present fundamental ideas and techniques of machine learning suitable for the field of this book, i.e., for automated scientific discovery. The chapter focuses on those symbolic machine learning methods, which produce results that are suitable to be interpreted and understood by humans. This is particularly important in the context of automated scientific discovery as the scientific theories to be produced by machines are usually meant to be interpreted by humans. This chapter contains some of the most influential ideas and concepts in machine learning research to give the reader a basic insight into the field. After the introduction in Sect. 1, general ideas of how learning problems can be framed are given in Sect. 2. The section provides useful perspectives to better understand what learning algorithms actually do. Section 3 presents the Version space model which is an early learning algorithm as well as a conceptual framework, that provides important insight into the general mechanisms behind most learning algorithms. In section 4, a family of learning algorithms, the AQ family for learning classification rules is presented. The AQ family belongs to the early approaches in machine learning. The next, Sect. 5 presents the basic principles of decision tree learners. Decision tree learners belong to the most influential class of inductive learning algorithms today. Finally, a more recent group of learning systems are presented in Sect. 6, which learn relational concepts within the framework of logic programming. This is a particularly interesting group of learning systems since the framework allows also to incorporate background knowledge which may assist in generalisation. Section 7 discusses Association Rules - a technique that comes from the related field of Data mining. Section 8 presents the basic idea of the Naive Bayesian Classifier. While this is a very popular learning technique, the learning result is not well suited for

  1. New concept of refrigeration. ; Magnetic refrigeration. Goku teion gijutsu. ; Jiki reito wo chushin to shite

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H.; Nakagome, H. (Toshiba Corp., Tokyo (Japan))

    1990-07-05

    This paper explained the principle, construction and problems of magnetic refrigeration which is an advanced refrigerartion technique. When strong field is applied to a paramagnet from the outside, the paramagnet bocomes a state of low entropy, that is, arranged electron spin. Adiabatic elimination of magnetic field deprives heat of lattice vibration of the paramagnet, returns it to the the entropy of electron spin without magnetic field, resulting itself to lower temperature state. This is the principle of adiabatic demaganetization by which a cycle to refrigerate and exhaust heat by a thermal switch can be constructed. But since the temperature range to which a paramagnet can exhibit the remarkable effect is limited, major problems are the selection of optimal paramagnet and how to get the AC or pulse magnetic field, although the practically necessary field may be obtained by a superconducting magnet. National Research Institute of Metals in Science and Technology Agency manufactured trially a stationary type magnetic refrigerator, of which maximum refrigerating capability was 100mW at 2K and minimum reachable temperature was 1.5K. 9 refs., 13 figs.

  2. Charging machine

    International Nuclear Information System (INIS)

    Medlin, J.B.

    1976-01-01

    A charging machine for loading fuel slugs into the process tubes of a nuclear reactor includes a tubular housing connected to the process tube, a charging trough connected to the other end of the tubular housing, a device for loading the charging trough with a group of fuel slugs, means for equalizing the coolant pressure in the charging trough with the pressure in the process tubes, means for pushing the group of fuel slugs into the process tube and a latch and a seal engaging the last object in the group of fuel slugs to prevent the fuel slugs from being ejected from the process tube when the pusher is removed and to prevent pressure liquid from entering the charging machine. 3 claims, 11 drawing figures

  3. Electric machines

    CERN Document Server

    Gross, Charles A

    2006-01-01

    BASIC ELECTROMAGNETIC CONCEPTSBasic Magnetic ConceptsMagnetically Linear Systems: Magnetic CircuitsVoltage, Current, and Magnetic Field InteractionsMagnetic Properties of MaterialsNonlinear Magnetic Circuit AnalysisPermanent MagnetsSuperconducting MagnetsThe Fundamental Translational EM MachineThe Fundamental Rotational EM MachineMultiwinding EM SystemsLeakage FluxThe Concept of Ratings in EM SystemsSummaryProblemsTRANSFORMERSThe Ideal n-Winding TransformerTransformer Ratings and Per-Unit ScalingThe Nonideal Three-Winding TransformerThe Nonideal Two-Winding TransformerTransformer Efficiency and Voltage RegulationPractical ConsiderationsThe AutotransformerOperation of Transformers in Three-Phase EnvironmentsSequence Circuit Models for Three-Phase Transformer AnalysisHarmonics in TransformersSummaryProblemsBASIC MECHANICAL CONSIDERATIONSSome General PerspectivesEfficiencyLoad Torque-Speed CharacteristicsMass Polar Moment of InertiaGearingOperating ModesTranslational SystemsA Comprehensive Example: The ElevatorP...

  4. General RMP Guidance - Appendix E: Supplemental Risk Management Program Guidance for Ammonia Refrigeration Facilities

    Science.gov (United States)

    Additional information for food processors, food distributors, refrigerated warehouses, and any other facility with ammonia refrigeration system. Includes guidance on exemptions, threshold quantity, offsite consequence analysis.

  5. Genesis machines

    CERN Document Server

    Amos, Martyn

    2014-01-01

    Silicon chips are out. Today's scientists are using real, wet, squishy, living biology to build the next generation of computers. Cells, gels and DNA strands are the 'wetware' of the twenty-first century. Much smaller and more intelligent, these organic computers open up revolutionary possibilities. Tracing the history of computing and revealing a brave new world to come, Genesis Machines describes how this new technology will change the way we think not just about computers - but about life itself.

  6. Towards High Performance in Industrial Refrigeration Systems

    DEFF Research Database (Denmark)

    Thybo, C.; Izadi-Zamanabadi, Roozbeh; Niemann, H.

    2002-01-01

    Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design in industr...... in industrial refrigeration systems.......Achieving high performance in complex industrial systems requires information manipulation at different system levels. The paper shows how different models of same subsystems, but using different quality of information/data, are used for fault diagnosis as well as robust control design...

  7. Flow-synchronous field motion refrigeration

    Science.gov (United States)

    Hassen, Charles N.

    2017-08-22

    An improved method to manage the flow of heat in an active regenerator in a magnetocaloric or an electrocaloric heat-pump refrigeration system, in which heat exchange fluid moves synchronously with the motion of a magnetic or electric field. Only a portion of the length of the active regenerator bed is introduced to or removed from the field at one time, and the heat exchange fluid flows from the cold side toward the hot side while the magnetic or electric field moves along the active regenerator bed.

  8. Microscopic model of a phononic refrigerator

    Science.gov (United States)

    Arrachea, Liliana; Mucciolo, Eduardo R.; Chamon, Claudio; Capaz, Rodrigo B.

    2012-09-01

    We analyze a simple microscopic model to pump heat from a cold to a hot reservoir in a nanomechanical system. The model consists of a one-dimensional chain of masses and springs coupled to a back gate through which a time-dependent perturbation is applied. The action of the gate creates a moving phononic barrier by locally pinning a mass. We solve the problem numerically using a nonequilibrium Green's function technique. For low driving frequencies and for sharp traveling barriers, we show that this microscopic model realizes a phonon refrigerator.

  9. A dilution refrigerator combining low base temperature, high cooling power and low heat leak for use with nuclear cooling

    International Nuclear Information System (INIS)

    Bradley, D.I.; Guenault, A.M.; Keith, V.; Miller, I.E.; Pickett, G.R.; Bradshaw, T.W.; Locke-Scobie, B.G.

    1982-01-01

    The design philosophy, design, construction and performance of a dilution refrigerator specifically intended for nuclear cooling experiments in the submillikelvin regime is described. Attention has been paid from the outset to minimizing sources of heat leaks, and to achieving a low base temperature and relatively high cooling power below 10 mK. The refrigerator uses sintered silver heat exchangers similar to those developed at Grenoble. The machine has a base temperature of 3 mK or lower and can precool a copper nuclear specimen in 6.8 T to 8 mK in 70 h. The heat leak to the innermost nuclear stage is < 30 pW after only a few days' running. (author)

  10. Evaluation of specific heat peak and half-width for magnetic regenerative materials (RCuO) of 4K refrigerator; 4K reitoki yo jisei chikureizai kagobutsu (RCuO) no hinetsu piku to hannehaba no hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, S.; Nakane, H.; Hashimoto, T.; Sakagami, H. [Kogakuin Univ., Tokyo (Japan); Okamura, M. [Toshiba Corp., Tokyo (Japan); Numazawa, T. [National Research Inst. for Metals, Tokyo (Japan)

    1999-11-10

    For material selection in the multistory structure regeneration vessel of the GM refrigerating machine, we have the meaning in which specific heat peak value and half-value width of material are important. It announced specific heat peak-half-value width characteristics of rare earth magnetic material RSb. For the purpose of searching new regeneration material it improves a refrigerating capacity of refrigerating machine for 4K, it evaluated R{sub 2}BaCuO{sub 5} mainly noticed as superconducting material and R{sub 2}Cu{sub 2}O{sub 5} specific heat peak and half-value width as a magnetic material, which covered the specific heat characteristics of helium in low temperature. (NEDO)

  11. Domestic Refrigeration, Freezer, and Window Air Conditioner Service. Teacher Edition.

    Science.gov (United States)

    Clemons, Mark

    This curriculum guide contains six units of instruction for a course in domestic refrigerator, freezer, and window air conditioner service. The units cover the following topics: (1) service fundamentals; (2) mechanical components and functions; (3) electrical components and control devices; (4) refrigerator and freezer service; (5) domestic ice…

  12. Nonlinear Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The main idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...... of a nonlinear controller. The proposed method is validated by experimental results....

  13. Profile: Department of Refrigeration and Heat Pump Technology

    OpenAIRE

    Sluis, S.M. van der

    2000-01-01

    The activities in the fields of refrigeration and heatpumps are concentrated within TNO Environment, Energy and Process Innovation, Apeldoorn, and specifically within the Department of Refrigeration and Heat Pump Technology. The aim of this department is to develop, implement and test: — systems for generating, distributing and using reftigeration; — heat pumps for heating purposes and industrial processes.

  14. Nonlinear Superheat Control of a Refrigeration Plant using Backstepping

    DEFF Research Database (Denmark)

    Rasmussen, Henrik

    2008-01-01

    This paper proposes a novel method for superheat and capacity control of refrigeration systems. The main idea is to control the superheat by the compressor speed and capacity by the refrigerant flow. A new low order nonlinear model of the evaporator is developed and used in a backstepping design...

  15. Refrigeration and Cryogenics Specialist. J3ABR54530

    Science.gov (United States)

    Air Force Training Command, Sheppard AFB, TX.

    This document package contains an Air Force course used to train refrigeration and cryogenics specialists. The course is organized in six blocks designed for group instruction. The blocks cover the following topics: electrical principles; fundamentals of tubing and piping; metering devices, motor controls, domestic and commercial refrigeration;…

  16. Control and optimization of the refrigeration plant in a brewery

    DEFF Research Database (Denmark)

    Petersen, P.M; Qvale, Einar Bjørn

    1989-01-01

    The design and operation of a refrigeration plant in a brewery has been studied. The plant has been evaluated by using mathematical models of the components to simulate responses to real-life load variations. The study shows that the efficiency and economy of the actual refrigeration plant could...

  17. US vaccine refrigeration guidelines: loose links in the cold chain.

    Science.gov (United States)

    McColloster, Patrick J

    2011-05-01

    This commentary compares Centers for Disease Control (CDC) guidelines for vaccine storage with international cold chain standards. Problems related to the use of domestic refrigerators in clinical settings are discussed. Optimal vaccine refrigerator design characteristics are summarized. The adoption of World Health Organization storage recommendations is advised.

  18. Refrigeration, Heating & Air Conditioning. Post Secondary Curriculum Guide.

    Science.gov (United States)

    Garrison, Joe C.; And Others

    This curriculum guide was designed for use in postsecondary refrigeration, heating and air conditioning education programs in Georgia. Its purpose is to provide for the development of entry level skills in refrigeration, heating, and air conditioning in the areas of air conditioning knowledge, theoretical structure, tool usage, diagnostic ability,…

  19. The Refrigeration System; Appliance Repair--Advanced: 9027.01.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This course outline provides students with an understanding of the observation of basic refrigeration system components, the techniques used in working with copper tubing, and practice demonstrations to show what they have learned. Course content includes specific block objectives, orientation, refrigeration components (evaporator, compressor,…

  20. Performance improvement clarification for refrigeration system using active system monitoring

    DEFF Research Database (Denmark)

    Green, Torben; Niemann, Hans Henrik; Izadi-Zamanabadi, Roozbeh

    2011-01-01

    This paper addresses the problem of determining whether a refrigeration plant has the possibility of delivering a better performance of the operation. The controllers are wellknown but detailed knowledge about the underlying dynamics of the refrigeration plant is not available. Thus, the question...