WorldWideScience

Sample records for absorption coefficient measurements

  1. Measured and numerically partitioned phytoplankton spectral absorption coefficients in inland waters

    NARCIS (Netherlands)

    Zhang, Y.; Liu, M.; Van Dijk, M.A.; Zhu, G.; Gong, Z.; Li, Y.M.; Qin, B.

    2009-01-01

    Total particulate, tripton and phytoplankton absorption coefficients were measured for eutrophic (Lake Taihu), meso-eutrophic (Lake Tianmuhu) and mesotrophic waters (the Three Gorges Reservoir) in China using the quantitative filter technique. Meanwhile, tripton and phytoplankton absorption

  2. Measurement of the absorption coefficient using the sound-intensity technique

    Science.gov (United States)

    Atwal, M.; Bernhard, R.

    1984-01-01

    The possibility of using the sound intensity technique to measure the absorption coefficient of a material is investigated. This technique measures the absorption coefficient by measuring the intensity incident on the sample and the net intensity reflected by the sample. Results obtained by this technique are compared with the standard techniques of measuring the change in the reverberation time and the standing wave ratio in a tube, thereby, calculating the random incident and the normal incident adsorption coefficient.

  3. In situ measurements of the oblique incidence sound absorption coefficient for finite sized absorbers

    DEFF Research Database (Denmark)

    Ottink, Marco; Brunskog, Jonas; Jeong, Cheol-Ho

    2016-01-01

    for the finiteness of the absorber. A sound field model, which accounts for scattering from the finite absorber edges, assuming plane wave incidence is derived. A significant influence of the finiteness on the radiation impedance and the corresponding absorption coefficient is found. A finite surface method, which......Absorption coefficients are mostly measured in reverberation rooms or with impedance tubes. Since these methods are only suitable for measuring the random incidence and the normal incidence absorption coefficient, there exists an increasing need for absorption coefficient measurement of finite...... absorbers at oblique incidence in situ. Due to the edge diffraction effect, oblique incidence methods considering an infinite sample fail to measure the absorption coefficient at large incidence angles of finite samples. This paper aims for the development of a measurement method that accounts...

  4. Measurement of the absorption coefficient of acoustical materials using the sound intensity method

    Science.gov (United States)

    Atwal, Mahabir S.; Crocker, Malcolm J.

    1987-01-01

    In this study the possibility of using the two-microphone sound intensity technique to measure the normal incidence and the random incidence sound absorption coefficient was investigated. The normal incidence absorption coefficient was determined by measuring the intensity incidence on the sample and the intensity reflected by the sample placed in an anechoic chamber. The random incidence absorption coefficient was determined by measuring the intensity incident on the sample and the intensity reflected by the sample placed in a reverberation chamber. Absorption coefficient results obtained by the sound intensity technique were compared with standard techniques, namely the reverberation chamber and the standing wave tube. The major advantages of using the sound intensity technique are that it permits 'in situ' measurements and the absorption coefficient for a large range of frequencies can be obtained from a single measurement.

  5. Producing of Impedance Tube for Measurement of Acoustic Absorption Coefficient of Some Sound Absorber Materials

    Directory of Open Access Journals (Sweden)

    R. Golmohammadi

    2008-04-01

    Full Text Available Introduction & Objective: Noise is one of the most important harmful agents in work environment. In spit of industrial improvements, exposure with over permissible limit of noise is counted as one of the health complication of workers. In Iran, do not exact information of the absorption coefficient of acoustic materials. Iranian manufacturer have not laboratory for measured of sound absorbance of their products, therefore using of sound absorber is limited for noise control in industrial and non industrial constructions. The goal of this study was to design an impedance tube based on pressure method for measurement of the sound absorption coefficient of acoustic materials.Materials & Methods: In this study designing of measuring system and method of calculation of sound absorption based on a available equipment and relatively easy for measurement of the sound absorption coefficient related to ISO10534-1 was performed. Measuring system consist of heavy asbestos tube, a pure tone sound generator, calibrated sound level meter for measuring of some commonly of sound absorber materials was used. Results: In this study sound absorption coefficient of 23 types of available acoustic material in Iran was tested. Reliability of results by three repeat of measurement was tested. Results showed that the standard deviation of sound absorption coefficient of study materials was smaller than .Conclusion: The present study performed a necessary technology of designing and producing of impedance tube for determining of acoustical materials absorption coefficient in Iran.

  6. Measurement of Absorption Coefficient of Paraformaldehyde and Metaldehyde with Terahertz Spectroscopy

    Science.gov (United States)

    Zhang, J.; Xia, T.; Chen, Q.; Sun, Q.; Deng, Y.; Wang, C.

    2018-03-01

    The characteristic absorption spectra of paraformaldehyde and metaldehyde in the terahertz frequency region are obtained by terahertz time-domain spectroscopy (THz-TDS). In order to reduce the absorption of terahertz (THz) wave by water vapor in the air and the background noise, the measurement system was filled with dry air and the measurements were conducted at the temperature of 24°C. Meanwhile, the humidity was controlled within 10% RH. The THz frequency domain spectra of samples and their references from 0 to 2.5 THz were analyzed via Fourier transform. The refractive index and absorption coefficients of the two aldehydes were calculated by the model formulas. From 0.1 to 2.5 THz, there appear two weak absorption peaks at 1.20 and 1.66 THz in the absorption spectra of paraformaldehyde. Only one distinct absorption peak emerges at 1.83 THz for metaldehyde. There are significant differences between the terahertz absorption coefficients of paraformaldehyde and metaldehyde, which can be used as "fingerprints" to identify these substances. Furthermore, the relationship between the average absorption coefficients and mass concentrations was investigated and the average absorption coefficient-mass concentration diagrams of paraformaldehyde and metaldehyde were shown. For paraformaldehyde, there is a linear relationship between the average absorption coefficient and the natural logarithm of mass concentration. For metaldehyde, there exists a simpler linear relationship between the average absorption coefficient and the mass concentration. Because of the characteristics of THz absorption of paraformaldehyde and metaldehyde, the THz-TDS can be applied to the qualitative and quantitative detection of the two aldehydes to reduce the unpredictable hazards due to these substances.

  7. In situ measurements of the oblique incidence sound absorption coefficient for finite sized absorbers.

    Science.gov (United States)

    Ottink, Marco; Brunskog, Jonas; Jeong, Cheol-Ho; Fernandez-Grande, Efren; Trojgaard, Per; Tiana-Roig, Elisabet

    2016-01-01

    Absorption coefficients are mostly measured in reverberation rooms or with impedance tubes. Since these methods are only suitable for measuring the random incidence and the normal incidence absorption coefficient, there exists an increasing need for absorption coefficient measurement of finite absorbers at oblique incidence in situ. Due to the edge diffraction effect, oblique incidence methods considering an infinite sample fail to measure the absorption coefficient at large incidence angles of finite samples. This paper aims for the development of a measurement method that accounts for the finiteness of the absorber. A sound field model, which accounts for scattering from the finite absorber edges, assuming plane wave incidence is derived. A significant influence of the finiteness on the radiation impedance and the corresponding absorption coefficient is found. A finite surface method, which combines microphone array measurements over a finite sample with the sound field model in an inverse manner, is proposed. Besides, a temporal subtraction method, a microphone array method, impedance tube measurements, and an equivalent fluid model are used for validation. The finite surface method gives promising agreement with theory, especially at near grazing incidence. Thus, the finite surface method is proposed for further measurements at large incidence angles.

  8. A numerical study of a method for measuring the effective in situ sound absorption coefficient

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, A

    2012-01-01

    The accuracy of a method [Wijnant et al., “Development and applica- tion of a new method for the in-situ measurement of sound absorption”, ISMA 31, Leuven, Belgium (2010).], for measurement of the effective area-averaged in situ sound absorption coefficient is investigated. Based on a local plane

  9. A numerical study of a method for measuring the effective in situ sound absorption coefficient.

    Science.gov (United States)

    Kuipers, Erwin R; Wijnant, Ysbrand H; de Boer, André

    2012-09-01

    The accuracy of a method [Wijnant et al., Proc. of ISMA 31, Leuven, Belgium (2010), Vol. 31] for measurement of the effective area-averaged in situ sound absorption coefficient is investigated. Based on a local plane wave assumption, this method can be applied to sound fields for which a model is not available. Investigations were carried out by means of finite element simulations for a typical case. The results show that the method is a promising method for determining the effective area-averaged in situ sound absorption coefficient in complex sound fields.

  10. Reproducibility of The Random Incidence Absorption Coefficient Converted From the Sabine Absorption Coefficient

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Chang, Ji-ho

    2015-01-01

    Absorption coefficients measured in reverberation chambers, Sabine absorption coefficients, suffer from two major problems. Firstly, they sometimes exceed unity. Secondly, the reproducibility of the Sabine absorption coefficients is quite poor, meaning that the Sabine absorption coefficients vary...... resistivity optimization outperforms the surface impedance optimization in terms of the reproducibility....

  11. Uncertainty analysis of standardized measurements of random-incidence absorption and scattering coefficients.

    Science.gov (United States)

    Müller-Trapet, Markus; Vorländer, Michael

    2015-01-01

    This work presents an analysis of the effect of some uncertainties encountered when measuring absorption or scattering coefficients in the reverberation chamber according to International Organization for Standardization/American Society for Testing and Materials standards. This especially relates to the uncertainty due to spatial fluctuations of the sound field. By analyzing the mathematical definition of the respective coefficient, a relationship between the properties of the chamber and the test specimen and the uncertainty in the measured quantity is determined and analyzed. The validation of the established equations is presented through comparisons with measurement data. This study analytically explains the main sources of error and provides a method to obtain the product of the necessary minimum number of measurement positions and the band center frequency to achieve a given maximum uncertainty in the desired quantity. It is shown that this number depends on the ratio of room volume to sample surface area and the reverberation time of the empty chamber.

  12. A comparison of the Standing Wave and Two Microphone Methods in Measuring The Sound Absorption Coefficient of Wood

    OpenAIRE

    Kang, Chunwon; Matsumura, Junji; Oda, Kazuyuki

    2006-01-01

    To compare the standing wave method with two microphone transfer function method in the measuring the sound absorption properties of wood, we measured the sound absorption coefficients of beech wood experimentally in the frequency range of 50 to 1600 Hz by the standing wave method and two-microphone method. The sound absorption coefficient under a continuous frequency range can be estimated in a shorter time by the two microphone transfer function method than the standing wave method. There...

  13. The Hyperspectral Absorption Sensor - Advantages and challenges of continuous, in situ absorption coefficient measurements

    Science.gov (United States)

    Wollschläger, J.; Röttgers, R.; Petersen, W.; Zielinski, O.

    2016-12-01

    A free-water mass balance-based study was conducted to address the rate of metabolism and net carbon exchange for the tidal wetland and estuarine portion of the coastal ocean and the uncertainties associated with this approach were assessed. Open water diurnal O2 and dissolved inorganic carbon (DIC) were measured seasonally in a salt marsh-estuary in Georgia, U.S.A. with a focus on the marsh-estuary linkage associated with tidal flooding. We observed that the overall estuarine system was a net source of CO2 to the atmosphere and coastal ocean and a net sink for oceanic and atmospheric O2. Rates of metabolism were extremely high, with respiration (43 mol m-2 yr-1) greatly exceeding gross primary production (28 mol m-2 yr-1), such that the overall system was net heterotrophic. Metabolism measured with DIC were higher than with O2, which we attribute to high rates of anaerobic respiration and reduced sulfur storage in salt marsh sediments, and we assume substantial levels of anoxygenic photosynthesis. We found gas exchange from a flooded marsh is substantial, accounting for about 28% of total O2 and CO2 air-water exchange. A significant percentage of the overall estuarine aquatic metabolism is attributable to metabolism of marsh organisms during inundation. Our study suggests not rely on oceanographic stoichiometry to convert from O2to C based measurements when constructing C balances for the coastal ocean. We also suggest eddy covariance measurements of salt marsh net ecosystem exchange underestimate net ecosystem production as they do not account for lateral DIC exchange associated with marsh tidal inundation. With the increase of global temperature and sea level rise, salt marshes are likely to export more inorganic carbon to the atmosphere and the coastal ocean due to the decrease of solubility, the increase of aquatic and benthic metabolic activities and the longer marsh inundation.

  14. Non-uniform sound intensity distributions when measuring absorption coefficients in reverberation chambers using a phased beam tracing.

    Science.gov (United States)

    Jeong, Cheol-Ho

    2010-06-01

    Measured absorption coefficients in reverberation chambers often differ from theoretical random incidence absorption coefficients, because ideal assumptions for the theoretical random incidence absorption coefficient are not fulfilled during measurements in actual reverberation chambers. Therefore sound intensity distributions on absorber under measurement conditions have been simulated using a phased beam tracing, and used as correction functions for reducing discrepancies between the measured and theoretical absorption coefficients. Two reverberation rooms were investigated by assuming that a test specimen was attached to a vertical surface and the floor. The frequency-dependent sound intensity distributions on absorbers were found to be affected by the reverberation chamber geometry and dimensions, the absorption capability of the specimen, and the placement of the specimen. High frequency intensity distributions above 1 kHz were similar for all studied cases, but some variations in low frequency intensity distributions were observed. If the non-uniform intensity distribution and a finite size effect are taken into account for correcting the theoretical absorption coefficients, a good agreement is found between corrected and measured statistical absorption coefficients. The non-uniform sound intensity can account for the discrepancy at high frequencies.

  15. Non-uniform sound intensity distributions when measuring absorption coefficients in reverberation chambers using a phased beam tracing

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2010-01-01

    sound intensity distributions on absorber under measurement conditions have been simulated using a phased beam tracing, and used as correction functions for reducing discrepancies between the measured and theoretical absorption coefficients. Two reverberation rooms were investigated by assuming...... that a test specimen was attached to a vertical surface and the floor. The frequency-dependent sound intensity distributions on absorbers were found to be affected by the reverberation chamber geometry and dimensions, the absorption capability of the specimen, and the placement of the specimen. High frequency...... agreement is found between corrected and measured statistical absorption coefficients. The non-uniform sound intensity can account for the discrepancy at high frequencies....

  16. Measurement of the sound absorption coefficient for an advanced undergraduate physics laboratory

    Science.gov (United States)

    Macho-Stadler, E.; Elejalde-García, M. J.

    2017-09-01

    We present a simple experiment that allows advanced undergraduates to learn the basics of the acoustic properties of materials. The impedance tube-standing wave method is applied to study the normal absorption coefficient of acoustics insulators. The setup includes a tube, a speaker, a microphone, a digital function generator and an oscilloscope, material available in an undergraduate laboratory. Results of the change of the absorption coefficient with the frequency, the sample thickness and the sample density are analysed and compared with those obtained with a commercial system.

  17. Measurement of the absorption coefficient of sound absorbing materials under a synthesized diffuse acoustic field.

    Science.gov (United States)

    Robin, Olivier; Berry, Alain; Doutres, Olivier; Atalla, Noureddine

    2014-07-01

    This letter proposes an experimental method to estimate the absorption coefficient of sound absorbing materials under a synthesized diffuse acoustic field in free-field conditions. Comparisons are made between experiments conducted with this approach, the standard reverberant room method, and numerical simulations using the transfer matrix method. With a simple experimental setup and smaller samples than those required by standards, the results obtained with the proposed approach do not exhibit non-physical trends of the reverberant room method and provide absorption coefficients in good agreement with those obtained by simulations for a laterally infinite material.

  18. Absorption coefficient of nearly transparent liquids measured using thermal lens spectrometry

    Directory of Open Access Journals (Sweden)

    H.Cabrera

    2006-01-01

    Full Text Available We use an optimized pump-probe mode-mismatched thermal lens scheme to determine the optical absorption coefficient and thermal diffusivity of ethanol, benzene, acetone, methanol, toluene and chloroform. In this scheme the excitation beam is focused in the presence of a collimated probe beam. The agreement between experimentally obtained results and values reported in the literature is good.

  19. Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2014-01-01

    into random incidence absorption coefficients for porous absorbers are investigated. Two optimization-based conversion methods are suggested: the surface impedance estimation for locally reacting absorbers and the flow resistivity estimation for extendedly reacting absorbers. The suggested conversion methods...

  20. Optical absorption coefficient and minority carrier diffusion length measurements in low-cost silicon solar cell material

    Energy Technology Data Exchange (ETDEWEB)

    Swimm, R.T.; Dumas, K.A.

    1982-11-01

    The optical absorption coefficient of silicon solar cell material grown by three low-cost growth methods was measured in the wavelength interval 0.8< or =lambda< or =1.0 ..mu..m, the wavelength region of interest in surface photovoltage measurements of the minority carrier diffusion length. The square root of the absorption coefficient was found to vary linearly with photon energy over the wavelengths studied, and the measured data agree with a linear empirical fit to within 0.5% RMS. The absorption coefficients obtained are slightly lower than those reported by Runyan, with the greatest disagreement at long wavelengths. Minority carrier diffusion lengths computed using the present absorption coefficients are approximately 16% greater than those calculated using Runyan's data. Excellent sample-to-sample agreement within and between lots indicates that for two of the growth methods studied, material quality as judged by optical properties has not been sacrificed by the use of low-cost growth methods. Samples grown by the third growth method studied showed measurably poorer optical quality.

  1. A Correction of Random Incidence Absorption Coefficients for the Angular Distribution of Acoustic Energy under Measurement Conditions

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2009-01-01

    Most acoustic measurements are based on an assumption of ideal conditions. One such ideal condition is a diffuse and reverberant field. In practice, a perfectly diffuse sound field cannot be achieved in a reverberation chamber. Uneven incident energy density under measurement conditions can cause...... discrepancies between the measured value and the theoretical random incidence absorption coefficient. Therefore the angular distribution of the incident acoustic energy onto an absorber sample should be taken into account. The angular distribution of the incident energy density was simulated using the beam...... tracing method for various room shapes and source positions. The averaged angular distribution is found to be similar to a Gaussian distribution. As a result, an angle-weighted absorption coefficient was proposed by considering the angular energy distribution to improve the agreement between...

  2. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Directory of Open Access Journals (Sweden)

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  3. Determination of scattering coefficient considering wavelength and absorption dependence of anisotropy factor measured by polarized beam for biological tissues

    Science.gov (United States)

    Fukutomi, D.; Ishii, K.; Awazu, K.

    2015-12-01

    Anisotropy factor g, one of the optical properties of biological tissues, is the most important parameter to accurately determine scattering coefficient μs in the inverse Monte Carlo (iMC) simulation. It has been reported that g has wavelength and absorption dependence, however, there are few attempts in order to calculate μs of biological tissue considering the wavelength and absorption dependence of g. In this study, the scattering angular distributions of biological tissue phantoms were measured in order to determine g by using goniometric measurements with three polarization conditions at strongly and weakly absorbing wavelengths of hemoglobin. Then, optical properties, especially, μs were measured by integrating sphere measurements and iMC simulation in order to confirm the influence of measured g on optical properties in comparison of with general value of g (0.9) for soft biological tissue. Consequently, it was found that μs was overestimated at strongly absorbing wavelength, however, μs was underestimated at weakly absorbing wavelength if the g was not considered its wavelength and absorption dependence.

  4. Experimental methodology for obtaining sound absorption coefficients

    Directory of Open Access Journals (Sweden)

    Carlos A. Macía M

    2011-07-01

    Full Text Available Objective: the authors propose a new methodology for estimating sound absorption coefficients using genetic algorithms. Methodology: sound waves are generated and conducted along a rectangular silencer. The waves are then attenuated by the absorbing material covering the silencer’s walls. The attenuated sound pressure level is used in a genetic algorithm-based search to find the parameters of the proposed attenuation expressions that include geometric factors, the wavelength and the absorption coefficient. Results: a variety of adjusted mathematical models were found that make it possible to estimate the absorption coefficients based on the characteristics of a rectangular silencer used for measuring the attenuation of the noise that passes through it. Conclusions: this methodology makes it possible to obtain the absorption coefficients of new materials in a cheap and simple manner. Although these coefficients might be slightly different from those obtained through other methodologies, they provide solutions within the engineering accuracy ranges that are used for designing noise control systems.

  5. Measurement of X-ray attenuation coefficients around K-absorption edges using Fe Kα X-rays

    International Nuclear Information System (INIS)

    Kerur, B.R.; Thontadarya, S.R.; Hanumaiah, B.

    1993-01-01

    The x-ray mass attenuation coefficients were measured around the K-absorption edges of elements in the range 16 ≤ Z ≤ 30 using Fe Kα x-rays of energy 6.400 keV, which is the weighted average energy of Kα 1 and Kα 2 x-ray components from the 57 Co radioactive source. Kβ x-rays were almost eliminated by the differential absorption technique. The small difference in energy between Kα 1 and Kα 2 , 13 eV, was shown to be inconsequential by comparing the measured and theoretical values of μ/ρ for standard materials such as Al, Cu, Mo and Ta. The effect of fine structure of the K-absorption edge on μ/ρ was elucidated by using the compounds of elements in the range 16 ≤ X ≤ 30, containing one element with its K-absorption edge energy (E k ) close to the incident photon energy (E x ). The results clearly indicate the validity of the theoretical mixture rule for all those compounds whose K edge is far away from the incident energy but show deviations of as much as 10% for the manganese compound whose K edge is 140 eV above E x and about 12% for the chromium compound whose K edge is 410 eV below E x . These deviations are attributed to the possible influence of resonance Raman scattering when the incident photon energy E x is less than the edge and to the influence of EXAFS when E x is more than the edge energy. (Author)

  6. Determination of absorption coefficients of glasses at high tempera-tures, by measuring the thermal emission

    NARCIS (Netherlands)

    Loenen, E.; Van der Tempel, L.

    1996-01-01

    An experimental setup built in 1995 measures the spectral absorptioncoefficient of glass as a function of temperature and wavelength bythe emissive method. The setup was improved, as well as the softwarefor processing the measurement data. The measurement results of quartzwere validated by

  7. Brillouin-scattering measurements of the acoustic absorption coefficient in liquid CS2

    Science.gov (United States)

    Coakley, R. W.; Detenbeck, R. W.

    1975-01-01

    High-resolution Brillouin spectra were recorded for light scattered at small angles from liquid CS2. The use of a single-mode He-Ne laser, locked in frequency to a Fabry-Perot interferometer, permitted measurements of line widths of the order of 10 MHz for frequencies in the range 300-1000 MHz. These measurements extend previous Brillouin line-width measurements at higher frequencies into the region where relaxation effects are dominant and connect the optical measurements with lower-frequency acoustical data.

  8. Absorption coefficient instrument for turbid natural waters

    Science.gov (United States)

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  9. Determination of ash content of coal by mass absorption coefficient measurements at two X-ray energies

    International Nuclear Information System (INIS)

    Fookes, R.A.; Gravitis, V.L.; Watt, J.S.

    1977-01-01

    A method for determining the ash content of coal is proposed. It involves measurements proportional to mass absorption coefficients of coal at two X-ray energies. These measurements can be made using X-ray transmission or scatter techniques. Calculations based on transmission of narrow beams of X-rays have shown that ash can be determined to about 1wt%(1 sigma) in coal of widely varying ash content and composition. Experimentally, ash content was determined to 0.67wt% by transmission techniques and 1.0wt% by backscatter techniques in coal samples from the Bulli seam, NSW, Australia, having ash in the range 11-34wt%. For samples with a much wider range of coal composition (7-53wt% ash and 0-25wt% iron in the ash), ash content was determined by backscatter measurements to 1.62wt%. The method produced ash determinations at least as accurate as those produced by the established technique which compensates for variation in iron content of the ash by X-ray fluorescence analysis for iron. Compared with the established technique, it has the advantage of averaging analysis over much larger volumes of coal, but the disadvantage that much more precise measurements of X-ray intensities are required. (author)

  10. Regularity of the interband light absorption coefficient

    Indian Academy of Sciences (India)

    In experimental studies the absorption coefficient is a means to study the band gaps at ... to l2( ), where. ⊂ Zd is a finite set. (usually taken to be a lattice cube centred at the origin) and λ±,uλ± are eigenvalues and eigenfunctions of H. ±. ,ω . Then the interband light absorption coefficient A for such finite volume models can.

  11. Evaluation of self-absorption coefficients of aluminum emission lines in laser-induced breakdown spectroscopy measurements

    International Nuclear Information System (INIS)

    El Sherbini, A.M.; El Sherbini, Th.M.; Hegazy, H.; Cristoforetti, G.; Legnaioli, S.; Palleschi, V.; Pardini, L.; Salvetti, A.; Tognoni, E.

    2005-01-01

    In quantitative Laser Induced Breakdown Spectroscopy (LIBS) measurements it is essential to account for the effect of self-absorption on the emission lines intensity. In order to quantify this effect, in this paper we propose a simple method for evaluating the ratio between the actual measured line intensity and the intensity expected in absence of self-absorption and, if necessary, correcting the effect of self-absorption on line intensity. The method, based on a homogeneous plasma model, is applicable when the plasma electron density is known and in particular to lines whose Stark broadening parameter is available

  12. Determination of self-absorption coefficient in measurement of solid sample activity using 4π ionization chamber

    International Nuclear Information System (INIS)

    Dryak, P.

    1982-01-01

    Computation based on the Monte Carlo method was tested for a 4π cylindrical ionization chamber with a detection volume of 7 litres, filled with argon. The sources are placed in the geometrical centre. The correction coefficient for self-absorption was determined as being the ratio of ionization currents induced by a source of finite size and by a massless point source. A flowchart of the program is given. The computations were experimentally tested for cylindrical sources of aqueous 137 Cs and 57 Co solutions. (M.D.)

  13. Regularity of the Interband Light Absorption Coefficient

    Indian Academy of Sciences (India)

    In this paper we consider the interband light absorption coefficient (ILAC), in a symmetric form, in the case of random operators on the -dimensional lattice. We show that the symmetrized version of ILAC is either continuous or has a component which has the same modulus of continuity as the density of states.

  14. An alternative coefficient for sound absorption

    NARCIS (Netherlands)

    Wijnant, Ysbrand H.; Kuipers, E.R.; de Boer, Andries; Sas, P; Jonckheere, S.; Moens, D.

    2013-01-01

    The acoustic absorption coefficient is a number that indicates which fraction of the incident acoustic power impinging on a surface is being absorbed. The incident acoustic power is obtained by spatial integration of the incident intensity, which is (classically) defined as the time-averaged

  15. Determination of the carrier concentration in CdSe crystals from the effective infrared absorption coefficient measured by means of the photothermal infrared radiometry

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, M. [Nicolaus Copernicus University, Faculty of Physics, Astronomy and Informatics, Institute of Physics, Torun (Poland)

    2014-11-11

    In this paper, a non-contact method that allows to determine the carrier concentration in CdSe crystals is presented. The method relies on the measurement of the effective infrared absorption coefficient by means of the photothermal infrared radiometry (PTR). In order to obtain the effective infrared absorption coefficient and thermal diffusivity, the frequency characteristics of the PTR signal were analyzed in the frame of a one-dimensional heat transport model for infrared semitransparent crystals. The carrier concentrations were estimated using a theory introduced by Ruda and a recently proposed normalization procedure for the PTR signal. The deduced carrier concentrations of the investigated CdSe crystals are in reasonable agreement with those obtained using Hall measurements and infrared spectroscopy. The method presented in this paper can also be applied to other semiconductors with the carrier concentration in the range of 10{sup 14}-10{sup 17} cm{sup -3}. (orig.)

  16. Aerosol Angstrom Absorption Coefficient Comparisons during MILAGRO.

    Science.gov (United States)

    Marley, N. A.; Marchany-Rivera, A.; Kelley, K. L.; Mangu, A.; Gaffney, J. S.

    2007-12-01

    Measurements of aerosol absorption were obtained as part of the MAX-Mex component of the MILAGRO field campaign at site T0 (Instituto Mexicano de Petroleo in Mexico City) by using a 7-channel aethalometer (Thermo- Anderson) during the month of March, 2006. The absorption measurements obtained in the field at 370, 470, 520, 590, 660, 880, and 950 nm were used to determine the aerosol Angstrom absorption exponents by linear regression. Since, unlike other absorbing aerosol species (e.g. humic like substances, nitrated PAHs), black carbon absorption is relatively constant from the ultraviolet to the infrared with an Angstrom absorption exponent of -1 (1), a comparison of the Angstrom exponents can indicate the presence of aerosol components with an enhanced UV absorption over that expected from BC content alone. The Angstrom exponents determined from the aerosol absorption measurements obtained in the field varied from - 0.7 to - 1.3 during the study and was generally lower in the afternoon than the morning hours, indicating an increase in secondary aerosol formation and photochemically generated UV absorbing species in the afternoon. Twelve-hour integrated samples of fine atmospheric aerosols (Petroleo (IMP) and CENICA.

  17. A Fiberoptic Irradiance Microsensor (Cosine Collector) - Application for In-Situ Measurements of Absorption-Coefficients in Sediments and Microbial Mats

    DEFF Research Database (Denmark)

    LASSEN, C.; JØRGENSEN, BB

    1994-01-01

    microsensor was used concurrently with fiber-optic microsensors for radiance and scalar irradiance in two cyanobacterial mats: a gelatinous laminated mat of Aphanothece sp. and Phormidium sp. and a compact marine intertidal mat of Microcoleus chthonoplastes. At the surface, the ratio of scalar irradiance...... at all wavelenghts and a maximum of 3.9 was reached in the gelatinous mat at both 675 and 760 nm. The results stress the importance of measuring the right light parameter when photobiological processes in sediments are investigated and the application of scalar irradiance and irradiance as quantitative...... measures of available light for photosynthesis parameter is discussed. From the distribution of scalar irradiance and irradiance, in situ absorption coefficients were calculated. Within the upper 3 mm of the gelatinous mat, the vertical attenuation coefficients of scalar irradiance, upward radiance...

  18. Determination of the X-ray mass absorption coefficient by measurement of the intensity of AgKα Compton scattered radiation

    International Nuclear Information System (INIS)

    Franzini, M.; Leoni, L.; Saitta, M.

    1976-01-01

    By utilizing a reflection geometry, an accurate mass absorption coefficient of a sample can be determined by measuring the Ag Kα Compton intensity. Intensities of Ag Kα Compton scattered radiation have been collected by using either the usual reflection geometry of a Philips PW 1450 automatic x-ray spectrometer or a more refined reflection geometry, achieved on a Philips PW 1540/10A manual x-ray spectrometer. The experimental results have shown that the relationship between the Ag Kα Compton intensity and the mass absorption is a logarithmic function. The experimental results are not in agreement with those reported in literature, but a theoretical explanation to account for this fact has not been achieved as yet. (author)

  19. Theoretical assessment of sound absorption coefficient for anisotropic nonwovens

    Directory of Open Access Journals (Sweden)

    Klara Kalinova

    2012-03-01

    Full Text Available The anisotropy factor as a function of fiber arrangement, fiber fineness and sample thickness has been derived from the theories of soundwave transformation due to phase changing. The sound absorption coefficient of the anisotropic fibrous material is then theoretically calculated. The fibrous materials were prepared so that the fibers are arranged parallel (perpendicularly laid fiber web called STRUTO technology in the direction of soundwave propagation or perpendicularly (longitudinally laid fiber web to the direction of sound propagation. The sound absorption coefficient was measured due to the Impedance tube. The theoretical results are in good agreement with experimental findings.

  20. Estimating the Sabine absorption coefficient of fibrous materials for various backing conditions

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2017-01-01

    Since absorber manufacturers cannot provide the absorption coefficients for all possible mounting conditions, acousticians have difficulties knowing the absorption characteristics of their own configurations. This paper aims to predict the Sabine absorption coefficient for various mounting...... conditions by extracting the air flow resistivity of the test specimen and the frequency-dependent effect of the chamber on the measured absorption coefficients. Two homogeneous fibrous absorbers are measured for experimental validation, showing good agreements between the predictions and measurements...

  1. Simultaneous measurement of thermal diffusivity and effective infrared absorption coefficient in IR semitransparent and semiconducting n-CdMgSe crystals using photothermal radiometry

    Energy Technology Data Exchange (ETDEWEB)

    Pawlak, M., E-mail: mpawlak@fizyka.umk.pl [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziądzka 5/7, Toruń (Poland); Maliński, M. [Department of Electronics and Computer Science, Koszalin University of Technology, 2 Śniadeckich St., Koszalin 75-453 (Poland)

    2015-01-10

    Highlights: • The new method of determination of the effective infrared absorption coefficient is presented. • The method can be used for transparent samples for the excitation radiation. • The effect of aluminum foil on the PTR signal in a transmission configuration is discussed. - Abstract: In this paper we propose a new procedure of simultaneous estimation of the effective infrared optical absorption coefficient and the thermal diffusivity of solid state samples using the photothermal infrared radiometry method in the transmission configuration. The proposed procedure relies on the analysis of the frequency dependent signal obtained from the samples covered with thin aluminum foil. This method can be applied for both optically opaque and transparent samples. The proposed method is illustrated with the results of the thermal diffusivity and the effective IR absorption coefficient obtained for several Cd{sub 1−x}Mg{sub x}Se crystals.

  2. Equivalent Black Carbon measurements and spectral analysis of absorption coefficient during a biomass burning episode in the city of Bogotá, Colombia.

    Science.gov (United States)

    Quirama, M.; Morales, R.

    2016-12-01

    Light-absorbing carbonaceous aerosol is recognized as a significant short lived climate pollutant that can contribute to direct and indirect radiative forcing. In urban environments, black carbon is an important contributor to the deterioration of local air quality. In this study, we report measurements of equivalent Black Carbon performed during the months of January, February, and March 2016 in the city of Bogotá, Colombia. During this period, a persistent condition of atmospheric stability lead to high concentrations of particulate matter throughout the city. During the month of February, the city was further impacted by a series of small-scale forest fires that took place on hills neighboring the city center. Equivalent Black Carbon (eBC) concentrations were monitored before, during, and after a mayor forest fire episode with a 7-wavelength Aethalometer. The monitoring instruments were located at a traffic impacted site, 18.3 km from the forest fire. To evaluate the contribution of biomass burning to the light-absorbing aerosol particle concentration, spectral analysis of the absorption coefficient of the sampled aerosol particles was performed. When the biomass burning plume directly impacted the monitoring station during the night of February 4, eBC concentrations of up to 40 µg/m3 were observed at nighttime. This concentration was significantly higher than average nighttime concentrations of eBC, observed to be 4 µg/m3 at the site. However, during the period most intensely affected by the biomass burning plume, the angstrom exponent computed between the 450nm and the 970 nm channel, was found to be close to 1. Angstrom exponent close to 1 is an indication that the contribution from traffic generated black carbon is dominant compared to the contribution of biomass burning. The data set collected during this period suggests that despite the significant contribution of the fresh biomass burning plume to the particulate matter concentration in the city, the

  3. Estimation of water absorption coefficient using the TDR method

    Science.gov (United States)

    Suchorab, Zbigniew; Majerek, Dariusz; Brzyski, Przemysław; Sobczuk, Henryk; Raczkowski, Andrzej

    2017-07-01

    Moisture accumulation and transport in the building barriers is an important feature that influences building performance, causing serious exploitation problems as increased energy use, mold and bacteria growth, decrease of indoor air parameters that may lead to sick building syndrome (SBS). One of the parameters that is used to describe moisture characteristic of the material is water absorption coefficient being the measure of capillary behavior of the material as a function of time and the surface area of the specimen. As usual it is determined using gravimetric methods according to EN 1925:1999 standard. In this article we demonstrate the possibility of determination of water absorption coefficient of autoclaved aerated concrete (AAC) using the Time Domain Reflectometry (TDR) method. TDR is an electric technique that had been adopted from soil science and can be successfully used for real-time monitoring of moisture transport in building materials and envelopes. Data achieved using TDR readouts show high correlation with standard method of moisture absorptivity coefficient determination.

  4. Calculation of effective absorption coefficient for aerosols of internal mixture

    International Nuclear Information System (INIS)

    Xu Bo; Huang Yinbo; Fan Chengyu; Qiao Chunhong

    2012-01-01

    The effective absorption coefficient with time of strong absorbing aerosol made of carbon dusts and water of internal mixture is analyzed, and the influence of different wavelengths and radius ratios on it is discussed. The shorter the wavelength is, the larger the effective absorption coefficient is , and more quickly it increases during 1-100 μs, and the largest increase if 132.65% during 1-100 μs. Different ratios between inner and outer radius have large influence on the effective absorption coefficient. The larger the ratio is, the larger the effective absorption coefficient is, and more quickly it increases during 1-100 μs. The increase of the effective absorption coefficient during 1-100 μs is larger than that during 100-1000 μs, and the largest increase is 138.66% during 1-100 μs. (authors)

  5. Measuring of heat transfer coefficient

    DEFF Research Database (Denmark)

    Henningsen, Poul; Lindegren, Maria

    Subtask 3.4 Measuring of heat transfer coefficient Subtask 3.4.1 Design and setting up of tests to measure heat transfer coefficient Objective: Complementary testing methods together with the relevant experimental equipment are to be designed by the two partners involved in order to measure...... the heat transfer coefficient for a wide range of interface conditions in hot and warm forging processes. Subtask 3.4.2 Measurement of heat transfer coefficient The objective of subtask 3.4.2 is to determine heat transfer values for different interface conditions reflecting those typically operating in hot...

  6. Modelling the light absorption coefficients of oceanic waters: Implications for underwater optical applications

    Science.gov (United States)

    Prabhakaran, Sai Shri; Sahu, Sanjay Kumar; Dev, Pravin Jeba; Shanmugam, Palanisamy

    2018-05-01

    Spectral absorption coefficients of particulate (algal and non-algal components) and dissolved substances are modelled and combined with the pure seawater component to determine the total light absorption coefficients of seawater in the Bay of Bengal. Two parameters namely chlorophyll-a (Chl) concentration and turbidity were measured using commercially available instruments with high sampling rates. For modelling the light absorption coefficients of oceanic waters, the measured data are classified into two broad groups - algal dominant and non-algal particle (NAP) dominant. With these criteria the individual absorption coefficients of phytoplankton and NAP were established based on their concentrations using an iterative method. To account for the spectral dependence of absorption by phytoplankton, the wavelength-dependent coefficients were introduced into the model. The CDOM absorption was determined by subtracting the individual absorption coefficients of phytoplankton and NAP from the measured total absorption data and then related to the Chl concentration. Validity of the model is assessed based on independent in-situ data from certain discrete locations in the Bay of Bengal. The total absorption coefficients estimated using the new model by considering the contributions of algal, non-algal and CDOM have good agreement with the measured total absorption data with the error range of 6.9 to 28.3%. Results obtained by the present model are important for predicting the propagation of the radiant energy within the ocean and interpreting remote sensing observation data.

  7. Restricted mass energy absorption coefficients for use in dosimetry

    International Nuclear Information System (INIS)

    Brahme, A.

    1977-02-01

    When matter is irradiated by a photon beam the fraction of energy absorbed locally in some region Rsub(Δ) (where the size of the region Rsub(Δ) is related to the range of secondary electrons of some restriction energy Δ) is expressed by the restricted mass energy absorption coefficient. In this paper an example is given of how restricted mass energy absorption coefficients can be calculated from existing differential photon interaction cross sections. Some applications of restricted mass absorption coefficients in dosimetry are also given. (B.D.)

  8. Retrieving complex surface impedances from statistical absorption coefficients

    DEFF Research Database (Denmark)

    Mondet, Boris Jean-Francois; Brunskog, Jonas; Jeong, Cheol-Ho

    2017-01-01

    coefficients, prior information about the absorber of interest can be used as constraints, which is shown to help determine the correct impedance from absorption coefficient. Further stability and sensitivity investigations indicate that the method presented constitutes an efficient solution to convert sound......In room acoustic simulations the surface materials are commonly represented with energy parameters, such as the absorption and scattering coefficients, which do not carry phase information. This paper presents a method to transform statistical absorption coefficients into complex surface impedances...... that the impedance found has a physical meaning and respects causality in the time domain. Known material models, such as Miki’s and Maa’s models, are taken as references to assess the validity of the suggested model. Due to the non-uniqueness of retrieving complex-valued impedances from real-valued absorption...

  9. Use of appropriate absorption coefficients in gamma-ray dosimetry

    International Nuclear Information System (INIS)

    Gopinath, D.V.; Natarajan, A.; Subbaiah, K.V.

    1985-01-01

    The current use of the different types of absorption coefficients in the computation of γ-ray energy deposition rates and air dose is critically analyzed. Transport calculations are presented to bring out the errors associated with the use of different absorption coefficients. It is observed that except for source energies in the range of 0.3 to 3.0 MeV the consistent use of the absorption coefficient, μ/sub a/ results in an underestimate of the air dose everywhere and of energy deposition at regions away from source. The underestimate becomes more significant with increased atomic number (Z) of the medium. Based on the computations and analysis it is concluded that the absorption coefficients μ/sub a/ and μ/sub k/ are of very limited use in practical γ-ray dosimetry

  10. Measurements of the speed of sound and the absorption coefficient for ion exchange resin embedded in concrete and bitumen using ultrasonic waves at around 0.1 MHz

    International Nuclear Information System (INIS)

    Sjoeblom, R.

    1981-01-01

    Ultrasonic measurements have been carried out on concrete and bitumen containing ion exchange resin. The speed and absorption of sound was determined for different amounts of resin, different times after preparation of the samples, and for different temperatures. The absorption data indicate that it should be possible to use the technique on full-scale waste products. The data also indicate that the velocity of sound is sensitive to several parameters of interest in radioactive waste treatment and storage. The technique may also be used to gain information on the internal disposition of a waste package. (Auth.)

  11. Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

    Science.gov (United States)

    Kessler, W. J.; Carleton, K. L.; Marinelli, W. J.

    1993-01-01

    Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

  12. Reflection and absorption coefficients for use in room acoustic simulations

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    Two ideas to improve the boundary conditions for room acoustic simulations are presented. First, all rooms have finite boundary surfaces, thereby a reflection coefficient for finite surfaces should be physically more suitable than that for infinitely large surfaces. Second, absorption coefficients...

  13. Regularity of the interband light absorption coefficient

    Indian Academy of Sciences (India)

    that the symmetrized version of ILAC is either continuous or has a component which has the same modulus of continuity as the .... and Rω = −ω and P = ×μ with a probability measure μ on R. If μ is continuous, then the density of states is ..... Proof. We note that as in eq. (1.3.4) [9], we have by integration by parts,. 1 h(a).

  14. Predicted sound absorption coefficients of absorber materials lined in a chamber

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2014-01-01

    Full Text Available Aims: The present study was aimed to measurement of sound absorption coefficient of mineral wool and determination of their absorption ability. Materials and Methods: Mineral wool was used to find noise absorption coefficient. Random and normal sound absorption coefficient values were predicted. Then, the measures of transmission loss calculated as an overall value, for applied absorbent material and bare sheet metal. Results: The measured values of noise with one octave band frequency demonstrated an attenuation of 5.5-7 dB for these frequencies. The absorption coefficients of materials showed that mineral wool had more normal sound coefficients than its random sound absorption coefficient values. Conclusion: It can be concluded that predicted normal sound absorption coefficients of used mineral wool materials were near to the areas of standard line. It seems that the amount or thickness of absorbent lining was a main reason of noise reduction in low band frequencies. Mineral wool has a higher density and can provide better acoustical and insulating results than fiberglass. Besides, mineral wool doesn′t lose its insulating value when wet and has an outstanding resistance to fire.

  15. On the sound absorption coefficient of porous asphalt pavements for oblique incident sound waves

    NARCIS (Netherlands)

    Bezemer-Krijnen, Marieke; Wijnant, Ysbrand H.; de Boer, Andries; Bekke, Dirk; Davy, J.; Don, Ch.; McMinn, T.; Dowsett, L.; Broner, N.; Burgess, M.

    2014-01-01

    A rolling tyre will radiate noise in all directions. However, conventional measurement techniques for the sound absorption of surfaces only give the absorption coefficient for normal incidence. In this paper, a measurement technique is described with which it is possible to perform in situ sound

  16. First sound absorption and dissipation coefficients of HeII

    International Nuclear Information System (INIS)

    Adamenko, I.N.; Belyaev, N.R.; Tsyganok, V.I.

    1988-01-01

    The first sound absorption coefficient is obtained on the basis of kinetic equations for phonons and rotons. The second viscosity coefficient of He II is calculated at different pressures in a wide temperature range including the phonon-roton and pure phonon regions and taking into account the inelastic phonon scattering by rotons and the phonon spectrum dispersion. The calculation is compared with experimental results

  17. Lifshitz Tails for the Interband Light Absorption Coefficient

    Indian Academy of Sciences (India)

    In this paper we consider the interband light absorption coefficient (ILAC) for various models. We show that at the lower and upper edges of the spectrum the Lifshitz tails behaviour of the density of states implies similar behaviour for the ILAC at appropriate energies. The Lifshitz tails property is also exhibited at some points ...

  18. Determination of sedimentation rates and absorption coefficient of ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    particles have pores that can absorb radiation. Gamma rays have been used to study the absorption coefficients of cobalt(II) insoluble compounds (Essien and Ekpe, 1998), densities of marine sediments. (Gerland and Villinger, 1995) and soil particle-size distribution (Vaz et al., 1992). In this study, sedimentation rates of ...

  19. The mass energy transfer and mass absorption coefficients

    International Nuclear Information System (INIS)

    Tomljenovic, I.; Stankovic, S.; Ninkovic, M.

    2002-01-01

    The calculation of the mass energy transfer and the mass absorption coefficients is presented and data for their change by energy, in range from 0,01 MeV to 10 MeV, are given. Data are numerically and graphically presented for following materials: air, water, polyethylene, lucite and polystyrene (author)

  20. On the Pressure and Temperature Dependence of the Absorption Coefficient of NH3

    Directory of Open Access Journals (Sweden)

    F. Aousgi

    2011-01-01

    Full Text Available The effects of pressure and temperature on the absorption coefficient of ammonia (NH3 gas self-perturbed and perturbed by nitrogen (N2 gas have been measured. We varied the gas pressure from 10 to 160 Torr and the temperature from 235 to 296 K in order to study the absorption coefficient at the center and the wings of lines in the ν4 band of NH3. These measurements were made using a high resolution (0.0038 cm-1 Bruker Fourier-transform spectrometer. These spectra have been analyzed using the method of multipressure technique permitting to succeed to an evolution of the absorption coefficient with the pressure and the quantum numbers J and K of the NH3 molecule. The results show that the absorption coefficient varies as a quadratic function of the pressure at the center of a given line. However, it has a linear evolution in the wings of the line. Moreover, the absorption coefficients are inversely proportional to temperature in the wings when NH3 lines are broadened by N2. The retrieved values of these coefficients were used to derive the temperature dependence of N2 broadening NH3 lines. The absorption coefficients were shown to fit closely the well-known exponential law.

  1. Measurements of thermal accommodation coefficients.

    Energy Technology Data Exchange (ETDEWEB)

    Rader, Daniel John; Castaneda, Jaime N.; Torczynski, John Robert; Grasser, Thomas W.; Trott, Wayne Merle

    2005-10-01

    A previously-developed experimental facility has been used to determine gas-surface thermal accommodation coefficients from the pressure dependence of the heat flux between parallel plates of similar material but different surface finish. Heat flux between the plates is inferred from measurements of temperature drop between the plate surface and an adjacent temperature-controlled water bath. Thermal accommodation measurements were determined from the pressure dependence of the heat flux for a fixed plate separation. Measurements of argon and nitrogen in contact with standard machined (lathed) or polished 304 stainless steel plates are indistinguishable within experimental uncertainty. Thus, the accommodation coefficient of 304 stainless steel with nitrogen and argon is estimated to be 0.80 {+-} 0.02 and 0.87 {+-} 0.02, respectively, independent of the surface roughness within the range likely to be encountered in engineering practice. Measurements of the accommodation of helium showed a slight variation with 304 stainless steel surface roughness: 0.36 {+-} 0.02 for a standard machine finish and 0.40 {+-} 0.02 for a polished finish. Planned tests with carbon-nanotube-coated plates will be performed when 304 stainless-steel blanks have been successfully coated.

  2. Theoretical assessment of sound absorption coefficient for anisotropic nonwovens

    OpenAIRE

    Klara Kalinova

    2012-01-01

    The anisotropy factor as a function of fiber arrangement, fiber fineness and sample thickness has been derived from the theories of soundwave transformation due to phase changing. The sound absorption coefficient of the anisotropic fibrous material is then theoretically calculated. The fibrous materials were prepared so that the fibers are arranged parallel (perpendicularly laid fiber web called STRUTO technology) in the direction of soundwave propagation or perpendicularly (longitudinally la...

  3. Aerosol Absorption Measurements in MILAGRO.

    Science.gov (United States)

    Gaffney, J. S.; Marley, N. A.; Arnott, W. P.; Paredes-Miranda, L.; Barnard, J. C.

    2007-12-01

    to carbonyl- and nitro- functional groups on conjugated and aromatic organic structures (e.g. PAH, and terpene derived products). Using 12-hour fine (0.1-1.0 micron) aerosol samples collected in the field on quartz filters, uv/vis and infrared spectra were obtained in the laboratory using integrating spheres and diffuse reflectance spectroscopy, respectively. An inter-comparison of the "real-time" measurements made by the photo-acoustic, aethalometer and MAAP techniques have been described. In addition, the in situ aethalometer (seven-channel) results are compared with continuous integrating sphere uv-visible spectra to examine the angstrom absorption coefficient variance. These results will be briefly overviewed and the specific posters detailing these results will be highlighted highlighted. This work was performed as part of the Department of Energy's Megacity Aerosol Experiment - Mexico City under the support of the Atmospheric Science Program. "This researchwas supported by the Office of Science (BER), U. S. Department of Energy, Grant No. DE-FG02-07ER64329.

  4. Measuring sound absorption using local field assumptions

    NARCIS (Netherlands)

    Kuipers, E.R.

    2013-01-01

    To more effectively apply acoustically absorbing materials, it is desirable to measure angle-dependent sound absorption coefficients, preferably in situ. Existing measurement methods are based on an overall model of the acoustic field in front of the absorber, and are therefore sensitive to

  5. EXTENSION OF THE INVERSE ADDING-DOUBLING METHOD TO THE MEASUREMENT OF WAVELENGTH-DEPENDENT ABSORPTION AND SCATTERING COEFFICIENTS OF BIOLOGICAL SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Allegood, M.S.; Baba, J.S.

    2008-01-01

    Light interaction with biological tissue can be described using three parameters: the scattering and absorption coeffi cients (μs and μa), as well as the anisotropy (g) which describes the directional dependence of the scattered photons. Accurately determining these optical properties for different tissue types at specifi c wavelengths simultaneously would be benefi cial for a variety of different biomedical applications. The goal of this project was to take a user defi ned g-value and determine the remaining two parameters for a specifi ed wavelength range. A fully automated computer program and process was developed to collect data for all wavelengths in a timely and accurate manner. LabVIEW® was used to write programs to automate raw intensity data collection from a spectrometer equipped integrating sphere, conversion of the data into a format for analysis via Scott Prahl’s Inverse Adding-Doubling (IAD) C code execution, and fi nally computation of the optical properties based on the output from the IAD code. To allow data to be passed effi ciently between LabVIEW® and C code program modules, the two were combined into a single program (OPT 3.1). OPT 3.1 was tested using tissue mimicking phantoms. Determination of the absorption and scattering coeffi cients showed excellent agreement with theory for wavelengths where the user inputted single g-value was suffi ciently precise. Future improvements entail providing for multi-wavelength g-value entry to extend the accuracy of results to encompass the complete multispectral range. Ultimately, the data collection process and algorithms developed through this effort will be used to examine actual biological tissues for the purpose of building and refi ning models for light-tissue interactions.

  6. Photosensitizer absorption coefficient modeling and necrosis prediction during Photodynamic Therapy.

    Science.gov (United States)

    Salas-García, Irene; Fanjul-Vélez, Félix; Arce-Diego, José Luis

    2012-09-03

    The development of accurate predictive models for Photodynamic Therapy (PDT) has emerged as a valuable tool to adjust the current therapy dosimetry to get an optimal treatment response, and definitely to establish new personal protocols. Several attempts have been made in this way, although the influence of the photosensitizer depletion on the optical parameters has not been taken into account so far. We present a first approach to predict the spatio-temporal variation of the photosensitizer absorption coefficient during PDT applied to dermatological diseases, taking into account the photobleaching of a topical photosensitizer. This permits us to obtain the photons density absorbed by the photosensitizer molecules as the treatment progresses and to determine necrosis maps to estimate the short term therapeutic effects in the target tissue. The model presented also takes into account an inhomogeneous initial photosensitizer distribution, light propagation in biological media and the evolution of the molecular concentrations of different components involved in the photochemical reactions. The obtained results allow to investigate how the photosensitizer depletion during the photochemical reactions affects light absorption by the photosensitizer molecules as the optical radiation propagates through the target tissue, and estimate the necrotic tumor area progression under different treatment conditions. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Uncertainty analysis for the coefficient of band-to-band absorption of crystalline silicon

    Directory of Open Access Journals (Sweden)

    Carsten Schinke

    2015-06-01

    Full Text Available We analyze the uncertainty of the coefficient of band-to-band absorption of crystalline silicon. For this purpose, we determine the absorption coefficient at room temperature (295 K in the wavelength range from 250 to 1450 nm using four different measurement methods. The data presented in this work derive from spectroscopic ellipsometry, measurements of reflectance and transmittance, spectrally resolved luminescence measurements and spectral responsivity measurements. A systematic measurement uncertainty analysis based on the Guide to the expression of uncertainty in measurement (GUM as well as an extensive characterization of the measurement setups are carried out for all methods. We determine relative uncertainties of the absorption coefficient of 0.4% at 250 nm, 11% at 600 nm, 1.4% at 1000 nm, 12% at 1200 nm and 180% at 1450 nm. The data are consolidated by intercomparison of results obtained at different institutions and using different measurement approaches.

  8. Apparatus for measurement of coefficient of friction

    Science.gov (United States)

    Slifka, A. J.; Siegwarth, J. D.; Sparks, L. L.; Chaudhuri, Dilip K.

    1990-01-01

    An apparatus designed to measure the coefficient of friction in certain controlled atmospheres is described. The coefficient of friction observed during high-load tests was nearly constant, with an average value of 0.56. This value is in general agreement with that found in the literature and also with the initial friction coefficient value of 0.67 measured during self-mated friction of 440C steel in an oxygen environment.

  9. Water vapor absorption coefficients in the 8-13-micron spectral region - A critical review

    Science.gov (United States)

    Grant, William B.

    1990-01-01

    Measurements of water vapor absorption coefficients in the thermal IR atmospheric window (8-13 microns) during the past 20 years obtained by a variety of techniques are reviewed for consistency and compared with computed values based on the AFGL spectral data tapes. The methods of data collection considered were atmospheric long path absorption with a CO2 laser or a broadband source and filters, a White cell and a CO2 laser or a broadband source and a spectrometer, and a spectrophone with a CO2 laser. Advantages and disadvantages of each measurement approach are given as a guide to further research. Continuum absorption has apparently been measured accurately to about the 5-10 percent level in five of the measurements reported.

  10. Phytoplankton community dynamic detection from the chlorophyll-specific absorption coefficient in productive inland waters

    Directory of Open Access Journals (Sweden)

    Fernanda Sayuri Yoshino Watanabe

    2017-10-01

    Full Text Available Abstract Aim: In this research, we investigated the spectral variability of the specific phytoplankton absorption coefficient, a*φ, measured in a tropical meso-to-hypertrophic reservoir, aiming to find spectral features associated with the chlorophyll-a (chla and other accessory pigments present in different phytoplankton species. Methods To accomplish this research, two fieldworks were carried out in different seasons in order to report a high bio-optical variation. Phytoplankton absorption coefficient, aφ, and chla concentration were measured in laboratory to estimate a*φ. Results The outcomes have indicated that there is a remarkable phytoplankton community dynamic as spatially as seasonally. Chla absorption features were well-defined at 440 nm and 675 nm. Conclusions All the a*φ spectra exhibited the absorption peak around 630 nm associated with phycocyanin pigment present in cyanobacteria. Some spectra have shown a peak at about 460 nm, which is related to chlorophyll b and chlorophyll c (chlb and chlc, respectively found in different phytoplankton species. In turn, absorption features of carotenoids around 490 nm also were identified, however, well defined just in curves measured in austral autumn. Such spectral features are found in phytoplankton groups already identified in the study area such as Chlorophyceae, Bacillariophyceae, Cyanophyceae, Conjugatophyceae, Chrysophyceae, among others. We expect that the results are useful in researches about remote sensing of phytoplankton and eutrophication in reservoirs.

  11. Bayesian inference of the flow resistivity of a sound absorber and the room's influence on the Sabine absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho; Choi, Sang-Hyeon; Lee, Ikjin

    2017-01-01

    chamber significantly, whereas the flow resistivity is a rather reproducible material property, from which the absorptive characteristics can be calculated through reliable models. Using Sabine absorption coefficients measured in 13 European reverberation chambers, the maximum a posteriori......A Bayesian analysis is applied to determine the flow resistivity of a porous sample and the influence of the test chamber based on measured Sabine absorption coefficient data. The Sabine absorption coefficient measured in a reverberation chamber according to ISO 354 is influenced by the test...... and the uncertainty of the flow resistivity and the test chamber’s influence are estimated. Inclusion of more than one chamber’s absorption data helps the flow resistivity converge towards a reliable value with a standard deviation below 17%...

  12. Bayesian inference of the flow resistivity of a sound absorber and the room's influence on the Sabine absorption coefficients.

    Science.gov (United States)

    Jeong, Cheol-Ho; Choi, Sang-Hyeon; Lee, Ikjin

    2017-03-01

    A Bayesian analysis is applied to determine the flow resistivity of a porous sample and the influence of the test chamber based on measured Sabine absorption coefficient data. The Sabine absorption coefficient measured in a reverberation chamber according to ISO 354 is influenced by the test chamber significantly, whereas the flow resistivity is a rather reproducible material property, from which the absorptive characteristics can be calculated through reliable models. Using Sabine absorption coefficients measured in 13 European reverberation chambers, the maximum a posteriori and the uncertainty of the flow resistivity and the test chamber's influence are estimated. Inclusion of more than one chamber's absorption data helps the flow resistivity converge towards a reliable value with a standard deviation below 17%.

  13. Chlorophyll specific absorption coefficient and phytoplankton biomass in the Red Sea

    KAUST Repository

    Tiwari, Surya Prakash

    2015-01-01

    The role of total particulate matter, the sum of phytoplankton and nonalgal particles, is essential to understanding the distribution and pathways of particulate carbon in the ocean. Their relative contributions to light absorption and scattering are fundamental to understanding remotely sensed ocean color. Until recently, data regarding the contribution of phytoplankton and algal particles to the inherent optical properties of the Red Sea was nonexistent. Some of the first measurements of these inherent optical properties in the Red Sea including phytoplankton specific absorption coefficients (aph*(λ)) were obtained by the TARA Oceans expedition in January 2010. From these observations, chlorophyll a was calculated using the Line Height Method (LHM) that minimizes the contribution to total and particulate absorption by non-algal particles (NAP) and CDOM. Bricaud and Stramski’s (1990) a method was then used to decompose hyperspectral total particulate absorption into the contributions by phytoplankton and nonalgal particles.

  14. High temperature measurement of water vapor absorption

    Science.gov (United States)

    Keefer, Dennis; Lewis, J. W. L.; Eskridge, Richard

    1985-01-01

    An investigation was undertaken to measure the absorption coefficient, at a wavelength of 10.6 microns, for mixtures of water vapor and a diluent gas at high temperature and pressure. The experimental concept was to create the desired conditions of temperature and pressure in a laser absorption wave, similar to that which would be created in a laser propulsion system. A simplified numerical model was developed to predict the characteristics of the absorption wave and to estimate the laser intensity threshold for initiation. A non-intrusive method for temperature measurement utilizing optical laser-beam deflection (OLD) and optical spark breakdown produced by an excimer laser, was thoroughly investigated and found suitable for the non-equilibrium conditions expected in the wave. Experiments were performed to verify the temperature measurement technique, to screen possible materials for surface initiation of the laser absorption wave and to attempt to initiate an absorption wave using the 1.5 kW carbon dioxide laser. The OLD technique was proven for air and for argon, but spark breakdown could not be produced in helium. It was not possible to initiate a laser absorption wave in mixtures of water and helium or water and argon using the 1.5 kW laser, a result which was consistent with the model prediction.

  15. Aerosol optical absorption measurements with photoacoustic spectroscopy

    Science.gov (United States)

    Liu, Kun; Wang, Lei; Liu, Qiang; Wang, Guishi; Tan, Tu; Zhang, Weijun; Chen, Weidong; Gao, Xiaoming

    2015-04-01

    Many parameters related to radiative forcing in climate research are known only with large uncertainties. And one of the largest uncertainties in global radiative forcing is the contribution from aerosols. Aerosols can scatter or absorb the electromagnetic radiation, thus may have negative or positive effects on the radiative forcing of the atmosphere, respectively [1]. And the magnitude of the effect is directly related to the quantity of light absorbed by aerosols [2,3]. Thus, sensitivity and precision measurement of aerosol optical absorption is crucial for climate research. Photoacoustic spectroscopy (PAS) is commonly recognized as one of the best candidates to measure the light absorption of aerosols [4]. A PAS based sensor for aerosol optical absorption measurement was developed. A 532 nm semiconductor laser with an effective power of 160 mW was used as a light source of the PAS sensor. The PAS sensor was calibrated by using known concentration NO2. The minimum detectable optical absorption coefficient (OAC) of aerosol was determined to be 1 Mm-1. 24 hours continues measurement of OAC of aerosol in the ambient air was carried out. And a novel three wavelength PAS aerosol OAC sensor is in development for analysis of aerosol wavelength-dependent absorption Angstrom coefficient. Reference [1] U. Lohmann and J. Feichter, Global indirect aerosol effects: a review, Atmos. Chem. Phys. 5, 715-737 (2005) [2] M. Z. Jacobson, Strong radiative heating due to the mixing state of black carbon in atmospheric aerosols, Nature 409, 695-697 (2001) [3] V. Ramanathan and G. Carmichae, Global and regional climate changes due to black carbon, nature geoscience 1, 221-227 (2008) [4] W.P Arnott, H. Moosmuller, C. F. Rogers, T. Jin, and R. Bruch, Photoacoustic spectrometer for measuring light absorption by aerosol: instrument description. Atmos. Environ. 33, 2845-2852 (1999).

  16. Light Absorption Coefficients for Soluble Species in Snow, Dome C, Antarctica, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains light absorption coefficients for soluble chromophores (light-absorbing chemicals) and concentrations of hydrogen peroxide (HOOH) and nitrate...

  17. Bias in the absorption coefficient determination of a fluorescent dye, standard reference material 1932 fluorescein solution

    International Nuclear Information System (INIS)

    DeRose, Paul C.; Kramer, Gary W.

    2005-01-01

    The absorption coefficient of standard reference material[registered] (SRM[registered]) 1932, fluorescein in a borate buffer solution (pH=9.5) has been determined at λ=488.0, 490.0, 490.5 and 491.0 nm using the US national reference UV/visible spectrophotometer. The purity of the fluorescein was determined to be 97.6% as part of the certification of SRM 1932. The solution measured was prepared gravimetrically by diluting SRM 1932 with additional borate buffer. The value of the absorption coefficient was corrected for bias due to fluorescence that reaches the detector and for dye purity. Bias due to fluorescence was found to be on the order of -1% for both monochromatic and polychromatic (e.g., diode-array based) spectrophotometers

  18. Experimental approach for measuring cylindrical flexoelectric coefficients

    Science.gov (United States)

    Zhang, Shuwen; Liu, Kaiyuan; Wu, Tonghui; Xu, Minglong; Shen, Shengping

    2017-10-01

    Flexoelectricity is a property of dielectric materials by which applied strain gradients induce electric polarizations within dielectric materials. Experimental research into the tensor components of the flexoelectric coefficient is essential. In this work, an experimental approach for measurement of the flexoelectric coefficient tensor components in cylindrical coordinates is developed. Two different experimental methods are designed to obtain the two related unknown flexoelectric coefficient tensor components. Theoretical and finite element analyses are developed and simplified for each experiment, and the related designs are then tested to obtain the coupled electric polarization charges. The two unknown flexoelectric coefficient tensor components of polyvinylidene fluoride are then decoupled. This work provides an experimental method that can be used to obtain multiple unknown flexoelectric coefficient tensor components in solid dielectric materials.

  19. Examination of the Measurement of Absorption Using the Reverberant Room Method for Highly Absorptive Acoustic Foam

    Science.gov (United States)

    Hughes, William O.; McNelis, Anne M.; Chris Nottoli; Eric Wolfram

    2015-01-01

    The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.

  20. Temperature dependence of the absorption coefficient of water for midinfrared laser radiation

    NARCIS (Netherlands)

    Jansen, E. D.; van Leeuwen, T. G.; Motamedi, M.; Borst, C.; Welch, A. J.

    1994-01-01

    The dynamics of the water absorption peak around 1.94 microns was examined. This peak is important for the absorption of holmium and thulium laser radiation. To examine the effect of temperature on the absorption coefficient, the transmission of pulsed Ho:YAG, Ho:YAG, Ho:YSGG, and Tm:YAG laser

  1. Determination of Scattering and Absorption Coefficients for Plasma-Sprayed Yttria-Stabilized Zirconia Thermal Barrier Coatings at Elevated Temperatures

    Science.gov (United States)

    Eldridge, Jeffrey I.; Spuckler, Charles M.; Markham, James R.

    2009-01-01

    The temperature dependence of the scattering and absorption coefficients for a set of freestanding plasma-sprayed 8 wt% yttria-stabilized zirconia (8YSZ) thermal barrier coatings (TBCs) was determined at temperatures up to 1360 C in a wavelength range from 1.2 micrometers up to the 8YSZ absorption edge. The scattering and absorption coefficients were determined by fitting the directional-hemispherical reflectance and transmittance values calculated by a four-flux Kubelka Munk method to the experimentally measured hemispherical-directional reflectance and transmittance values obtained for five 8YSZ thicknesses. The scattering coefficient exhibited a continuous decrease with increasing wavelength and showed no significant temperature dependence. The scattering is primarily attributed to the relatively temperature-insensitive refractive index mismatch between the 8YSZ and its internal voids. The absorption coefficient was very low (less than 1 per centimeter) at wavelengths between 2 micrometers and the absorption edge and showed a definite temperature dependence that consisted of a shift of the absorption edge to shorter wavelengths and an increase in the weak absorption below the absorption edge with increasing temperature. The shift in the absorption edge with temperature is attributed to strongly temperature-dependent multiphonon absorption. While TBC hemispherical transmittance beyond the absorption edge can be predicted by a simple exponential decrease with thickness, below the absorption edge, typical TBC thicknesses are well below the thickness range where a simple exponential decrease in hemispherical transmittance with TBC thickness is expected. [Correction added after online publication August 11, 2009: "edge to a shorter wavelengths" has been updated as edge to shorter wavelengths."

  2. A theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls.

    Science.gov (United States)

    Hanyu, Toshiki

    2010-09-01

    This paper describes the development of a theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls. The concepts of equivalent scattering area, equivalent scatter reflection area, average scattering coefficient and average scatter reflection coefficient are introduced in order to express all walls' capability of scatter in a room. Using these concepts and the mean free path, scatter-to-absorption ratio, mean scatter time and diffusion time are defined in order to evaluate degree of diffusion of a space. Furthermore the effect of spatial scattering objects to sound field diffusion is formulated. In addition the time variation of specular and scattered components in a room impulse response is formulated. The verification of these characterization methods was performed with computer simulations based on the sound ray tracing method. The results supported that the ideas presented are basically valid.

  3. Measuring Resource Inequality: The Gini Coefficient

    Directory of Open Access Journals (Sweden)

    Michael T. Catalano

    2009-07-01

    Full Text Available This paper stems from work done by the authors at the Mathematics for Social Justice Workshop held in June of 2007 at Middlebury College. We provide a description of the Gini coefficient and some discussion of how it can be used to promote quantitative literacy skills in mathematics courses. The Gini Coefficient was introduced in 1921 by Italian statistician Corrado Gini as a measure of inequality. It is defined as twice the area between two curves. One, the Lorenz curve for a given population with respect to a given resource, represents the cumulative percentage of the resource as a function of the cumulative percentage of the population that shares that percentage of the resource. The second curve is the line y = x which is the Lorenz curve for a population which shares the resource equally. The Gini coefficient can be interpreted as the percentage of inequality represented in the population with respect to the given resource. We propose that the Gini coefficient can be used to enhance students’ understanding of calculus concepts and provide practice for students in using both calculus and quantitative literacy skills. Our examples are based mainly on distribution of energy resources using publicly available data from the Energy Information Agency of the United States Government. For energy resources within the United States, we find that by household, the Gini coefficient is 0.346, while using the 51 data points represented by the states and Washington D.C., the Gini coefficient is 0.158. When we consider the countries of the world as a population of 210, the Gini coefficient is 0.670. We close with ideas for questions which can be posed to students and discussion of the experiences two other mathematics instructors have had incorporating the Gini coefficient into pre-calculus-level mathematics classes.

  4. Friction Coefficient Determination by Electrical Resistance Measurements

    Science.gov (United States)

    Tunyagi, A.; Kandrai, K.; Fülöp, Z.; Kapusi, Z.; Simon, A.

    2018-01-01

    A simple and low-cost, DIY-type, Arduino-driven experiment is presented for the study of friction and measurement of the friction coefficient, using a conductive rubber cord as a force sensor. It is proposed for high-school or college/university-level students. We strongly believe that it is worthwhile planning, designing and performing Arduino…

  5. Comparative study of sound absorption coefficient determination using FEM method and experimental tests on Kundt's tube

    Science.gov (United States)

    Deaconu, Marius; Toma, Adina Cristina; Dragasanu, Luminita Ioana; Mihai, Dragos

    2017-06-01

    Sound absorption coefficient is a commonly used parameter to characterize the acoustic properties of sound absorbing materials that plays an important role in noise attenuation. For this study a specific material has been chosen in order to be evaluated experimentally and compared with the simulated results. Both simulation and experimental assessments used to estimate the sound absorption coefficient are based on transfer function method in accordance with standard SR EN JSO 10354-2. Results are obtained for 15, 30, 45 mm material sample thickness in order to assess the relationship between absorption coefficient, thickness and frequency response. Comparative analysis is performed to determine differences given by the two approaches.

  6. The Effect of New Collision-Induced Absorption Coefficients on the Early Mars Limit Cycle Hypothesis

    Science.gov (United States)

    Hayworth, B. P.; Payne, R. C.; Kasting, J. F.

    2017-11-01

    Updating the Limit Cycling (LC) Model for early Mars with new absorption coefficients to test for changes to LC behavior and to potentially lower needed concentrations of greenhouse gases. Thought will be given to the effect of LC on habitability.

  7. Preliminary results of an algorithm to determine the total absorption coefficient of water

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.; Talaulikar, M.; Desa, E.J.; Lotlikar, A.

    An algorithm to determine the spectral total absorption coefficient of water is presented. The algorithm is based on the Gershun’s equation of alfa = micro KE. The spectral underwater average cosine, micro and vertical attenuation...

  8. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  9. Varying coefficients model with measurement error.

    Science.gov (United States)

    Li, Liang; Greene, Tom

    2008-06-01

    We propose a semiparametric partially varying coefficient model to study the relationship between serum creatinine concentration and the glomerular filtration rate (GFR) among kidney donors and patients with chronic kidney disease. A regression model is used to relate serum creatinine to GFR and demographic factors in which coefficient of GFR is expressed as a function of age to allow its effect to be age dependent. GFR measurements obtained from the clearance of a radioactively labeled isotope are assumed to be a surrogate for the true GFR, with the relationship between measured and true GFR expressed using an additive error model. We use locally corrected score equations to estimate parameters and coefficient functions, and propose an expected generalized cross-validation (EGCV) method to select the kernel bandwidth. The performance of the proposed methods, which avoid distributional assumptions on the true GFR and residuals, is investigated by simulation. Accounting for measurement error using the proposed model reduced apparent inconsistencies in the relationship between serum creatinine and GFR among different clinical data sets derived from kidney donor and chronic kidney disease source populations.

  10. Determination of the absorption coefficient of chromophoric dissolved organic matter from underway spectrophotometry.

    Science.gov (United States)

    Dall'Olmo, Giorgio; Brewin, Robert J W; Nencioli, Francesco; Organelli, Emanuele; Lefering, Ina; McKee, David; Röttgers, Rüdiger; Mitchell, Catherine; Boss, Emmanuel; Bricaud, Annick; Tilstone, Gavin

    2017-11-27

    Measurements of the absorption coefficient of chromophoric dissolved organic matter (ay) are needed to validate existing ocean-color algorithms. In the surface open ocean, these measurements are challenging because of low ay values. Yet, existing global datasets demonstrate that ay could contribute between 30% to 50% of the total absorption budget in the 400-450 nm spectral range, thus making accurate measurement of ay essential to constrain these uncertainties. In this study, we present a simple way of determining ay using a commercially-available in-situ spectrophotometer operated in underway mode. The obtained ay values were validated using independent collocated measurements. The method is simple to implement, can provide measurements with very high spatio-temporal resolution, and has an accuracy of about 0.0004 m -1 and a precision of about 0.0025 m -1 when compared to independent data (at 440 nm). The only limitation for using this method at sea is that it relies on the availability of relatively large volumes of ultrapure water. Despite this limitation, the method can deliver the ay data needed for validating and assessing uncertainties in ocean-colour algorithms.

  11. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  12. Peltier coefficient measurement in a thermoelectric module

    International Nuclear Information System (INIS)

    Garrido, Javier; Casanovas, Alejandro; Chimeno, José María

    2013-01-01

    A new method for measuring the Peltier coefficient in a thermocouple X/Y based on the energy balance at the junction has been proposed recently. This technique needs only the hot and cold temperatures of a thermoelectric module when an electric current flows through it as the operational variables. The temperature evolutions of the two module sides provide an evident and accurate idea of the Peltier effect. From these temperatures, the heat transfer between the module and the ambient is also evaluated. The thermoelectric phenomena are described in the framework of an observable theory. Based on this procedure, an experiment is presented for a university teaching laboratory at the undergraduate level. (paper)

  13. Friction coefficient determination by electrical resistance measurements

    Science.gov (United States)

    Tunyagi, A.; Kandrai, K.; Fülöp, Z.; Kapusi, Z.; Simon, A.

    2018-05-01

    A simple and low-cost, DIY-type, Arduino-driven experiment is presented for the study of friction and measurement of the friction coefficient, using a conductive rubber cord as a force sensor. It is proposed for high-school or college/university-level students. We strongly believe that it is worthwhile planning, designing and performing Arduino and compatible sensor-based experiments in physics class in order to ensure a better understanding of phenomena, develop theoretical knowledge and multiple experimental skills.

  14. Sound absorption coefficient in situ: an alternative for estimating soil loss factors.

    Science.gov (United States)

    Freire, Rosane; Meletti de Abreu, Marco Henrique; Okada, Rafael Yuri; Soares, Paulo Fernando; GranhenTavares, Célia Regina

    2015-01-01

    The relationship between the sound absorption coefficient and factors of the Universal Soil Loss Equation (USLE) was determined in a section of the Maringá Stream basin, Paraná State, by using erosion plots. In the field, four erosion plots were built on a reduced scale, with dimensions of 2.0×12.5m. With respect to plot coverage, one was kept with bare soil and the others contained forage grass (Brachiaria), corn and wheat crops, respectively. Planting was performed without any type of conservation practice in an area with a 9% slope. A sedimentation tank was placed at the end of each plot to collect the material transported. For the acoustic system, pink noise was used in the measurement of the proposed monitoring, for collecting information on incident and reflected sound pressure levels. In general, obtained values of soil loss confirmed that 94.3% of material exported to the basin water came from the bare soil plot, 2.8% from the corn plot, 1.8% from the wheat plot, and 1.1% from the forage grass plot. With respect to the acoustic monitoring, results indicated that at 16kHz erosion plot coverage type had a significant influence on the sound absorption coefficient. High correlation coefficients were found in estimations of the A and C factors of the USLE, confirming that the acoustic technique is feasible for the determination of soil loss directly in the field. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Evaluation of the Extinction Coefficient, Radiation Absorption and Use Efficiency of Saffron (Crocus sativus L.

    Directory of Open Access Journals (Sweden)

    Seyyedeh Maliheh Mirhashemi

    2015-10-01

    Full Text Available Leaf area index, light extinction coefficient and radiation use efficiency are important eco-physiological characteristics for realization of crops growth, development and radiation absorption. In order to determine the leaf area index (LAI, light extinction coefficient (K and radiation use efficiency (RUE of saffron during the first and second growing seasons, four experiments were started in 2011 and ended in 2014, at the Research Farm of the Agriculture Faculty, the Ferdowsi University of Mashhad, Iran. Saffron corms with weights between 13 to15 g and density of 50 plant.m2 were cultivated in 2011 and 2012. In all experimental years during the growing season, crop sampling was taken for required measurements including the leaf area index and shoot dry weight of saffron once every 14 days. The results showed that by increasing the age of saffron from 1 year to two years, the maximum LAI of saffron increased from 0.33 to 1.81, and light extinction coefficient decreased from 1.20 to 0.54. The increasing trend of LAI was coincident with fraction of absorbed radiation for all four years of the experiment. In the first and the second growing seasons, the amount of fraction of absorbed radiation gradually increased with increasing LAI and at 1083 and 1034 GDD reached its maximum value, respectively. In saffron farms when the plant was one year old and two years old, the mean value of RUE was 0.68 and 1.73 g.MJ-1 PAR, respectively. These results indicate that by increasing the saffron age and LAI, the value of K decreases and consequently radiation absorption and use efficiency will‎ increase.

  16. Measurements of soil-solution distribution coefficient

    International Nuclear Information System (INIS)

    Tsukada, Hirofumi; Hasegawa, Hidenao; Hisamatsu, Shunichi; Sakurai, Naoyuki; Koyama, Kenji

    1999-01-01

    The soil-solution distribution coefficient (Kd) is defined as the ratio of element concentrations in a soil-solid phase to that in a solution phase. It is commonly used as an important parameter for transfer models of radionuclides in different environments, such as describing the migration behavior in the geosphere and transfer behavior in the biosphere. We plan to measure the Kd of elements by means of an extraction method in soils throughout Aomori Prefecture and to probe related factors affecting their variance. However, Kd values vary widely, dependent upon conditions of measurements even if a similar soil sample is measured. Therefore, measurement conditions for the Kd of elements were examined in the present study and the following conditions were adopted. A collected soil sample was passed through a 2 mm sieve and dried at 50degC. The ratio of solution to solid was 10. The mixture sample was shaken for 24 h at 20degC in a clean centrifuge bottle which was made of polypropylene copolymer (PPCO). According to the literature, common soil types in Aomori Prefecture are as follows: andosols in the Sanpachi-Kamikita region, gray lowland and upland soils in the Tsugaru region, sand-dune regosols in Kizukuri-machi, peat soils around lakes and so on. The Kd values for those soil types will be measured hereafter. (author)

  17. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  18. The Optical Absorption Coefficient of Maize Grains Investigated by Photoacoustic Spectroscopy

    Science.gov (United States)

    Rodríguez-Páez, C. L.; Carballo-Carballo, A.; Rico-Molina, R.; Hernández-Aguilar, C.; Domínguez-Pacheco, A.; Cruz-Orea, A.; Moreno-Martínez, E.

    2017-01-01

    In the maize and tortilla industry, it is important to characterize the color of maize ( Zea mays L.) grain, as it is one of the attributes that directly affect the quality of the tortillas consumed by the population. For this reason, the availability of alternative techniques for assessing and improving the quality of grain is valued. Photoacoustic spectroscopy has proven to be a useful tool for characterizing maize grain. So, the objective of the present study was to determine the optical absorption coefficient β of the maize grain used to make tortillas from two regions of Mexico: (a) Valles Altos, 2012-2013 production cycle and (b) Guasave, Sinaloa, 2013-2014 production cycle. Traditional reflectance measurements, physical characteristics of the grain and nutrient content were also calculated. The experimental results show different characteristics for maize grains.

  19. Mapping Surface Water DOC in the Northern Gulf of Mexico Using CDOM Absorption Coefficients and Remote Sensing Imagery

    Science.gov (United States)

    Kelly, B.; Chelsky, A.; Bulygina, E.; Roberts, B. J.

    2017-12-01

    Remote sensing techniques have become valuable tools to researchers, providing the capability to measure and visualize important parameters without the need for time or resource intensive sampling trips. Relationships between dissolved organic carbon (DOC), colored dissolved organic matter (CDOM) and spectral data have been used to remotely sense DOC concentrations in riverine systems, however, this approach has not been applied to the northern Gulf of Mexico (GoM) and needs to be tested to determine how accurate these relationships are in riverine-dominated shelf systems. In April, July, and October 2017 we sampled surface water from 80+ sites over an area of 100,000 km2 along the Louisiana-Texas shelf in the northern GoM. DOC concentrations were measured on filtered water samples using a Shimadzu TOC-VCSH analyzer using standard techniques. Additionally, DOC concentrations were estimated from CDOM absorption coefficients of filtered water samples on a UV-Vis spectrophotometer using a modification of the methods of Fichot and Benner (2011). These values were regressed against Landsat visible band spectral data for those same locations to establish a relationship between the spectral data, CDOM absorption coefficients. This allowed us to spatially map CDOM absorption coefficients in the Gulf of Mexico using the Landsat spectral data in GIS. We then used a multiple linear regressions model to derive DOC concentrations from the CDOM absorption coefficients and applied those to our map. This study provides an evaluation of the viability of scaling up CDOM absorption coefficient and remote-sensing derived estimates of DOC concentrations to the scale of the LA-TX shelf ecosystem.

  20. Absorption coefficient measurrement of monochromatized synchrotron radiation at 0.65 - 1.3 A interval for some biological objects

    International Nuclear Information System (INIS)

    Avakian, Ts.M.; Karabekov, I.P.; Martirossian, M.A.

    1977-01-01

    The results of the measurement of absorption coefficients for some biological objects such as pea (Pissum sativum), wheat (Triticum aestivum), tobacco (Nicotiana-tabacum-α) seeds, as well as the distilled water are presented. The measurement has been carried out on the Erevan Physical Institute Electron Accelerator synchrotron radiation beam. The good agreement of experimental and calculated data for water confirms the accuracy of the results related to other objects

  1. Sound absorption coefficient of coal bottom ash concrete for railway application

    Science.gov (United States)

    Ramzi Hannan, N. I. R.; Shahidan, S.; Maarof, Z.; Ali, N.; Abdullah, S. R.; Ibrahim, M. H. Wan

    2017-11-01

    A porous concrete able to reduce the sound wave that pass through it. When a sound waves strike a material, a portion of the sound energy was reflected back and another portion of the sound energy was absorbed by the material while the rest was transmitted. The larger portion of the sound wave being absorbed, the lower the noise level able to be lowered. This study is to investigate the sound absorption coefficient of coal bottom ash (CBA) concrete compared to the sound absorption coefficient of normal concrete by carried out the impedance tube test. Hence, this paper presents the result of the impedance tube test of the CBA concrete and normal concrete.

  2. Tone-burst technique measures high-intensity sound absorption

    Science.gov (United States)

    Powell, J. G.; Van Houten, J. J.

    1971-01-01

    Tone-burst technique, in which narrow-bandwidth, short-duration sonic pulse is propagated down a standing-wave tube, measures sound absorbing capacity of materials used in jet engine noise abatement. Technique eliminates effects of tube losses and yields normal-incidence absorption coefficient of specimen.

  3. The frequency dispersion of velocity and sound waves absorption coefficient in the electrolyte solutions

    International Nuclear Information System (INIS)

    Odinaev, S.; Dodarbekov, A.

    2001-01-01

    Present article is devoted to frequency dispersion of velocity and sound waves absorption coefficient in the electrolyte solutions. The analytical expressions for acoustic parameters in a wide range of thermodynamic parameters and frequencies change were obtained. The system of equations of generalized hydrodynamics for electrolyte solutions was constructed.

  4. Optical properties of the adaxial and abaxial faces of leaves. Chlorophyll fluorescence, absorption and scattering coefficients.

    Science.gov (United States)

    Cordón, Gabriela B; Lagorio, María G

    2007-08-01

    Emission fluorescence spectra were obtained for the adaxial and abaxial faces of dicotyledonous (Ficus benjamina L., Ficus elastica, Gardenia jasminoides and Hedera helix) and monocotyledonous leaves (Gladiolus spp. and Dracaena cincta bicolor). After correction by light-re-absorption processes, using a previously published physical model, the adaxial faces of dicotyledons showed a fluorescence ratio Fred/Ffar-red rather lower than the respective values for the abaxial faces. Monocotyledons and shade-adapted-plants showed similar values for the corrected fluorescence ratio for both faces. Even when differences in experimental fluorescence emission from adaxial and abaxial leaves in dicotyledons are mostly due to light re-absorption processes, the residual dissimilarity found after application of the correction model would point to the fact that fluorescence re-absorption is not the only responsible for the observed disparity. It was concluded that light re-absorption processes does not account entirely for the differences in the experimental emission spectra between adaxial and abaxial leaves. Differences that remains still present after correction might be interpreted in terms of a different photosystem ratio (PSII/PSI). Experiments at low temperature sustained this hypothesis. In dicotyledons, light reflectance for adaxial leaves was found to be lower than for the abaxial ones. It was mainly due to an increase in the scattering coefficient for the lower leaf-side. The absorption coefficient values were slightly higher for the upper leaf-side. During senescence of Ficus benjamina leaves, the scattering coefficient increased for both the upper and lower leaf-sides. With senescence time the absorption coefficient spectra broadened while the corrected fluorescence ratio (Fred/Ffar-red) decreased for both faces. The results pointed to a preferential destruction of photosystem II relative to photosystem I during senescence.

  5. Statistical Models for Sediment/Detritus and Dissolved Absorption Coefficients in Coastal Waters of the Northern Gulf of Mexico

    National Research Council Canada - National Science Library

    Green, Rebecca E; Gould, Jr., Richard W; Ko, Dong S

    2008-01-01

    ... (CDOM) absorption coefficients from physical hydrographic and atmospheric properties. The models were developed for northern Gulf of Mexico shelf waters using multi-year satellite and physical data...

  6. Effects of heat treatment on sound absorption coefficients in nanosilver-impregnated and normal solid woods.

    Science.gov (United States)

    Esmailpour, Ayoub; Taghiyari, Hamid Reza; Zolfaghari, Habib

    2017-06-01

    Effects of impregnation with silver nano-suspension as well as heat-treatment on sound absorption coefficients (AC) were studied in tangential direction of five different solid woods based on their importance. AC was measured at two frequencies of 250 and 500 Hz. A 400 ppm nanosuspension was used for the impregnation; silver nanoparticles had a size range of 30-80 nm. Based on the obtained results, the species reacted significantly different in absorbing sound at the two frequencies. Impregnation with nano-suspension substantially decreased AC at the lower frequency of 250 Hz; it did not show any particular trend when AC was measured at the frequency of 500 Hz. Heat treatment significantly increased AC at the frequency of 250 Hz. ACs of mulberry tended to be similar at the two frequencies; in the other four species though, ACs were significantly different. High significant correlations were found in the hardwoods between the ACs measured at the two frequencies.

  7. Modelling of power-reactivity coefficient measurement

    International Nuclear Information System (INIS)

    Strmensky, C.; Petenyi, V.; Jagrik, J.; Minarcin, M.; Hascik, R.; Toth, L.

    2005-01-01

    Report describes results of modeling of power-reactivity coefficient analysis on power-level. In paper we calculate values of discrepancies arisen during transient process. These discrepancies can be arisen as result of experiment evaluation and can be caused by disregard of 3D effects on neutron distribution. The results are critically discussed (Authors)

  8. Measuring sound absorption: considerations on the measurement of the active acoustic power

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, Andries

    2014-01-01

    Using a local plane wave assumption, one can determine the normal incidence sound absorption coefficient of a surface by measuring the acoustic pressure and the particle velocity normal to that surface. As the measurement surface lies in front of the material surface, the measured active and

  9. Modeling of the Interminiband Absorption Coefficient in InGaN Quantum Dot Superlattices

    Directory of Open Access Journals (Sweden)

    Giovanni Giannoccaro

    2016-01-01

    Full Text Available In this paper, a model to estimate minibands and theinterminiband absorption coefficient for a wurtzite (WZ indium gallium nitride (InGaN self-assembled quantum dot superlattice (QDSL is developed. It considers a simplified cuboid shape for quantum dots (QDs. The semi-analytical investigation starts from evaluation through the three-dimensional (3D finite element method (FEM simulations of crystal mechanical deformation derived from heterostructure lattice mismatch under spontaneous and piezoelectric polarization effects. From these results, mean values in QDs and barrier regions of charge carriers’ electric potentials and effective masses for the conduction band (CB and three valence sub-bands for each direction are evaluated. For the minibands’ investigation, the single-particle time-independent Schrödinger equation in effective mass approximation is decoupled in three directions and resolved using the one-dimensional (1D Kronig–Penney model. The built-in electric field is also considered along the polar axis direction, obtaining Wannier–Stark ladders. Then, theinterminiband absorption coefficient in thermal equilibrium for transverse electric (TE and magnetic (TM incident light polarization is calculated using Fermi’s golden rule implementation based on a numerical integration into the first Brillouin zone. For more detailed results, an absorption coefficient component related to superlattice free excitons is also introduced. Finally, some simulation results, observations and comments are given.

  10. Friction Experiments for Dynamical Coefficient Measurement

    Directory of Open Access Journals (Sweden)

    J. J. Arnoux

    2011-01-01

    Full Text Available An experimental study, including three experimental devices, is presented in order to investigate dry friction phenomena in a wide range of sliding speeds for the steel on steel contact. A ballistic setup, with an air gun launch, allows to estimate the friction coefficient between 20 m/s and 80 m/s. Tests are completed by an adaptation of the sensor on a hydraulic tensile machine (0.01 m/s to 3 m/s and a pin-on-disk tribometer mounted on a CNC lathe (1 to 30 m/s. The interactions at the asperity scale are characterized by a white light interferometer surface analysis.

  11. NORMAL INCIDENCE SOUND ABSORPTION COEFFICIENT OF DIRECT PIERCING CARVED WOOD PANEL WITH DAUN SIREH MOTIF USING BOUNDARY ELEMENT METHOD

    Directory of Open Access Journals (Sweden)

    Mohd Zamri Jusoh

    2013-06-01

    Full Text Available The Direct Piercing Carved Wood Panel (DPCWP installed in Masjid Abidin, Kuala Terengganu, is one example that carries much aesthetic and artistic value. The use of DPCWP in earlier mosques was envisaged to improve the intelligibility of indoor speech because the perforated panels allow some of the sound energy to pass through. In this paper, the normal incidence sound absorption coefficient of DPCWP with Daun Sireh motif, which is a form of floral pattern, is discussed. The Daun Sireh motif was chosen and investigated for 30%, 35%, 40%, and 45% perforation ratios. The simulations were conducted using BEASY Acoustic Software based on the boundary element method. The simulation results were compared with measurements obtained by using the sound intensity technique. An accompanying discussion on both the numerical and the measurement tendencies of the sound absorption characteristics of the DPCWP is provided. The results show that the DPCWP with Daun Sireh motif can act as a good sound absorber.

  12. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption.

    Science.gov (United States)

    Calvo-Lerma, Joaquim; Martínez-Barona, Sandra; Masip, Etna; Fornés, Victoria; Ribes-Koninckx, Carmen

    2017-10-01

    Pancreatic enzyme replacement therapy (PERT) remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA). This is a retrospective longitudinal study of 16 pediatric patients (192 food records) with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat) and the variability in the PERT dose (standard deviation [SD]). The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  13. Backscattering and absorption coefficients for electrons: Solutions of invariant embedding transport equations using a method of convergence

    International Nuclear Information System (INIS)

    Figueroa, C.; Brizuela, H.; Heluani, S. P.

    2014-01-01

    The backscattering coefficient is a magnitude whose measurement is fundamental for the characterization of materials with techniques that make use of particle beams and particularly when performing microanalysis. In this work, we report the results of an analytic method to calculate the backscattering and absorption coefficients of electrons in similar conditions to those of electron probe microanalysis. Starting on a five level states ladder model in 3D, we deduced a set of integro-differential coupled equations of the coefficients with a method know as invariant embedding. By means of a procedure proposed by authors, called method of convergence, two types of approximate solutions for the set of equations, namely complete and simple solutions, can be obtained. Although the simple solutions were initially proposed as auxiliary forms to solve higher rank equations, they turned out to be also useful for the estimation of the aforementioned coefficients. In previous reports, we have presented results obtained with the complete solutions. In this paper, we present results obtained with the simple solutions of the coefficients, which exhibit a good degree of fit with the experimental data. Both the model and the calculation method presented here can be generalized to other techniques that make use of different sorts of particle beams

  14. Measurement of reactivity coefficients for code validation

    International Nuclear Information System (INIS)

    Nuding, Matthias; Loetsch, Thomas

    2005-01-01

    In the year 2003 measurements in the cold reactor state have been performed at the NPP KKI 2 in order to validate the codes that are used for reactor core calculations and especially for the proof of the shutdown margin that is produced by calculations only. For full power states code verification is quite easy because the calculations can be compared with different measured values, e.g. with the activation values determined by the aeroball system. For cold reactor states, however the data base is smaller, especially for reactor cores that are quite 'inhomogeneous' and have rather high Pu-fiss-and 235 U-contents. At the same time the cold reactor state is important regarding the shutdown margin. For these reasons the measurements mentioned above have been performed in order to check the accuracy of the codes that are used by the operator and by our organization for many years. Basically, boron concentrations and control rod worths for different configurations have been measured. The results of the calculation show a very good agreement with the measured values. Therefore, it can be stated that the operator's as well as our code system is suitable for routine use, e.g. during licensing procedures (Authors)

  15. Determination of absorption coefficient of Chlorella vulgaris and Arthrospira maxima in water

    Science.gov (United States)

    Tekiner, Murat; Kurt, Mustafa; Ak, Ilknur; Kurt, Arzu

    2018-02-01

    Safe drinking water is crucial for human healthy, nowadays all drinking and irrigation water in developed country commonly come from dams. The water is transported to our usage area by several type of pipe or water-trench. The water can be infected some bacteria such as Chlorella vulgaris, Arthrospira maxima, during this transportation. In this study, we determine which wavelength effect to these green algae and cyanobacteria. For different concentration of these microorganisms in water, we determined uv-vis spectrum. By analyzing these spectrums, we determined absorption coefficient of these microorganisms for selected wavelength. The results show which wavelength can be used for destroy these microorganisms in affected water.

  16. Measurement of conversion coefficients in 208Tl

    International Nuclear Information System (INIS)

    Wendling, F.

    1976-06-01

    A electron spectrometer composed by a Li drifted Si detector and a uniform magnetic field was constructed. The magnetic field is used to focus the electrons on the detector and to filter the other radiations. After the construction the instrument was calibrated in absolute eficience and was used together with a Ge(Li) spectrometer also calibrated, in the measurement of internal conversion coeficients of the 433 and 453 keV transitions in 208 Tl [pt

  17. Measurement of atomic number and mass attenuation coefficient in ...

    Indian Academy of Sciences (India)

    energy selective scintillation counter with radioactive γ-ray sources having energy 0.36,. 0.511, 0.662, 1.17 and 1.28 MeV. The experimentally obtained values of μ/ρ and Zeff agreed fairly well with those obtained theoretically. Keywords. Absorption; attenuation coefficient; effective atomic number. PACS Nos 29.40.Mc; 29.30 ...

  18. Time-resolved absorption measurements on OMEGA

    International Nuclear Information System (INIS)

    Jaanimagi, P.A.; DaSilva, L.; Delettrez, J.; Gregory, G.G.; Richardson, M.C.

    1986-01-01

    Time-resolved measurements of the incident laser light that is scattered and/or refracted from targets irradiated by the 24 uv-beam OMEGA laser at LLE, have provided some interesting features related to time-resolved absorption. The decrease in laser absorption characteristic of irradiating a target that implodes during the laser pulse has been observed. The increase in absorption expected as the critical density surface moves from a low to a high Z material in the target has also been noted. The detailed interpretation of these results is made through comparisons with simulation using the code LILAC, as well as with streak data from time-resolved x-ray imaging and spectroscopy. In addition, time and space-resolved imaging of the scattered light yields information on laser irradiation uniformity conditions on the target. The report consists of viewgraphs

  19. Carbonation Coefficients from Concrete Made with High-Absorption Limestone Aggregate

    Directory of Open Access Journals (Sweden)

    Eric I. Moreno

    2013-01-01

    Full Text Available Normal aggregates employed in concrete have absorption levels in the range of 0.2% to 4% for coarse aggregate and 0.2 to 2% for fine aggregate. However, some aggregates have absorption levels above these values. As the porosity of concrete is related to the porosity of both the cement paste and the aggregate and the carbonation rate is a function, among other things, of the porosity of the material, there is concern about the effect of this high porosity material in achieving good quality concrete from the durability point of view. Thus, the objective of this investigation was to study the carbonation rates of concrete specimens made with high-absorption limestone aggregate. Four different water/cement ratios were used, and cylindrical concrete specimens were exposed to accelerated carbonation. High porosity values were obtained for concrete specimens beyond the expected limits for durable concrete. However, carbonation coefficients related to normal quality concrete were obtained for the lowest water/cement ratio employed suggesting that durable concrete may be obtained with this material despite the high porosity.

  20. Determination of absorption coefficient based on laser beam thermal blooming in gas-filled tube.

    Science.gov (United States)

    Hafizi, B; Peñano, J; Fischer, R; DiComo, G; Ting, A

    2014-08-01

    Thermal blooming of a laser beam propagating in a gas-filled tube is investigated both analytically and experimentally. A self-consistent formulation taking into account heating of the gas and the resultant laser beam spreading (including diffraction) is presented. The heat equation is used to determine the temperature variation while the paraxial wave equation is solved in the eikonal approximation to determine the temporal and spatial variation of the Gaussian laser spot radius, Gouy phase (longitudinal phase delay), and wavefront curvature. The analysis is benchmarked against a thermal blooming experiment in the literature using a CO₂ laser beam propagating in a tube filled with air and propane. New experimental results are presented in which a CW fiber laser (1 μm) propagates in a tube filled with nitrogen and water vapor. By matching laboratory and theoretical results, the absorption coefficient of water vapor is found to agree with calculations using MODTRAN (the MODerate-resolution atmospheric TRANsmission molecular absorption database) and HITRAN (the HIgh-resolution atmospheric TRANsmission molecular absorption database).

  1. Density, ultrasound velocity, acoustic impedance, reflection and absorption coefficient determination of liquids via multiple reflection method.

    Science.gov (United States)

    Hoche, S; Hussein, M A; Becker, T

    2015-03-01

    The accuracy of density, reflection coefficient, and acoustic impedance determination via multiple reflection method was validated experimentally. The ternary system water-maltose-ethanol was used to execute a systematic, temperature dependent study over a wide range of densities and viscosities aiming an application as inline sensor in beverage industries. The validation results of the presented method and setup show root mean square errors of: 1.201E-3 g cm(-3) (±0.12%) density, 0.515E-3 (0.15%) reflection coefficient and 1.851E+3 kg s(-1) m(-2) (0.12%) specific acoustic impedance. The results of the diffraction corrected absorption showed an average standard deviation of only 0.12%. It was found that the absorption change shows a good correlation to concentration variations and may be useful for laboratory analysis of sufficiently pure liquids. The main part of the observed errors can be explained by the observed noise, temperature variation and the low signal resolution of 50 MHz. In particular, the poor signal-to-noise ratio of the second reflector echo was found to be a main accuracy limitation. Concerning the investigation of liquids the unstable properties of the reference material PMMA, due to hygroscopicity, were identified to be an additional, unpredictable source of uncertainty. While dimensional changes can be considered by adequate methodology, the impact of the time and temperature dependent water absorption on relevant reference properties like the buffer's sound velocity and density could not be considered and may explain part of the observed deviations. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Pancreatic enzyme replacement therapy in cystic fibrosis: dose, variability and coefficient of fat absorption

    Directory of Open Access Journals (Sweden)

    Joaquim Calvo-Lerma

    Full Text Available Objectives: Pancreatic enzyme replacement therapy (PERT remains a backbone in the nutritional treatment of cystic fibrosis. Currently, there is a lack of an evidence-based tool that allows dose adjustment. To date, no studies have found an association between PERT dose and fat absorption. Therefore, the aim of the study was to assess the influence of both the PERT dose and the variability in this dose on the coefficient of fat absorption (CFA. Methods: This is a retrospective longitudinal study of 16 pediatric patients (192 food records with three consecutive visits to the hospital over a twelve-month period. Dietary fat intake and PERT were assessed via a four-day food record and fat content in stools was determined by means of a three-day stool sample collection. A beta regression model was built to explain the association between the CFA and the interaction between the PERT dose (lipase units [LU]/g dietary fat and the variability in the PERT dose (standard deviation [SD]. Results: The coefficient of fat absorption increased with the PERT dose when the variability in the dose was low. In contrast, even at the highest PERT dose values, the CFA decreased when the variability was high. The confidence interval suggested an association, although the analysis was not statistically significant. Conclusion: The variability in the PERT dose adjustment should be taken into consideration when performing studies on PERT efficiency. A clinical goal should be the maintenance of a constant PERT dose rather than trying to obtain an optimal value.

  3. Questionnaire on the measurement condition of distribution coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Takebe, Shinichi; Kimura, Hideo; Matsuzuru, Hideo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    2001-05-01

    The distribution coefficient is used for various transport models to evaluate the migration behavior of radionuclides in the environment and is very important parameter in environmental impact assessment of nuclear facility. The questionnaire was carried out for the purpose of utilizing for the proposal of the standard measuring method of distribution coefficient. This report is summarized the result of questionnairing on the sampling methods and storage condition, the pretreatment methods, the analysis items in the physical/chemical characteristics of the sample, and the distribution coefficient measuring method and the measurement conditions in the research institutes within country. (author)

  4. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    Science.gov (United States)

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita

    2012-01-01

    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  5. Temperature-dependent absorption coefficient of the fourth sound in bulk liquid 4He near absolute zero temperature

    International Nuclear Information System (INIS)

    Jun, Chul Won; Um, C. I.

    2000-01-01

    The temperature-dependent absorption coefficient of the fourth sound is evaluated explicitly near absolute zero temperature via the temperature-dependent anomalous excitation spectrum in bulk liquid helium. The coefficient increases with decreasing temperature, and the main contribution is due to the thermal conductivity

  6. Brillouin scattering measurements of the temperature dependence of sound velocity and acoustic absorption in simple alcohols

    Science.gov (United States)

    Stevens, J. R.; Coakley, R. W.

    2011-07-01

    A scanning Fabry-Perot interferometer was used to measure Brillouin spectra of methanol, isopropanol and a 95% ethanol-water mixture for temperatures ranging between 285 K and 320 K. The Brillouin frequency shifts and linewidths were used to calculate the velocities and absorption coefficients of hypersonic acoustic waves in these liquids. The temperature dependence of sound speed and acoustic attenuation was determined. For all three materials, both sound velocity and absorption coefficient decreased with temperature.

  7. Mechanochemical synthesis of stoichiometric nickel and nickel-zinc ferrite powders with Nicolson-Ross analysis of absorption coefficients

    Directory of Open Access Journals (Sweden)

    Jovalekić Čedomir

    2012-01-01

    Full Text Available The interest in finding new methods for preparation of nickel ferrite (NiFe2O4 and nickel-zinc ferrite (NixZn1-xFe2O4 powders has recently increased, due to the fact that physical and chemical properties of these soft magnetic materials depend strongly on the preparation conditions. In this paper, powder samples of ferrites were obtained by: 1 classic sintering procedure (NixZn1-xFe2O4, x = 0.9 and 2 planetary mill synthesis (both NiFe2O4 and NixZn1-xFe2O4. Mechanochemical reaction leading to the formation of NixZn1-xFe2O4 (x = 1 and 0.9 spinel phase was monitored by SEM, TEM, and XRD. Values of the real and imaginary parts of permittivity and permeability were measured for the obtained nickel and nickel-zinc ferrite samples in the 7-12 GHz frequency range. Based on the obtained results, the EMR absorption coefficients were calculated for all three sample types. It has been concluded that the method of preparation and the final particle size influence the EMR absorption coefficient of nickel and nickel-zinc ferrites.

  8. Measurement of chemical diffusion coefficients in liquid binary alloys

    International Nuclear Information System (INIS)

    Keita, M.; Steinemann, S.; Kuenzi, H.U.

    1976-01-01

    New measurements of the chemical diffusion coefficient in liquid binary alloys are presented. The wellknown geometry of the 'capillary-reservoir' is used and the concentration is obtained from a resistivity measurement. The method allows to follow continuously the diffusion process in the liquid state. A precision of at least 10% in the diffusion coefficient is obtained with a reproductibility better than 5%. The systems Hg-In, Al-Sn, Al-Si have been studied. Diffusion coefficients are obtained as a function of temperature, concentration, and geometrical factors related to the capillary (diameter, relative orientation of density gradient and gravity). (orig.) [de

  9. Coefficient of Performance Optimization of Single-Effect Lithium-Bromide Absorption Cycle Heat Pumps

    DEFF Research Database (Denmark)

    Vinther, Kasper; Just Nielsen, Rene; Nielsen, Kirsten Mølgaard

    2015-01-01

    In this paper, we investigate the coefficient of performance (COP) of a LiBr absorption cycle heat pump under different operating conditions. The investigation is carried out using a dynamical model fitted against data recorded from an actual heat pump used for district heating in S......⊘nderborg, Denmark. Since the model is too complex to study analytically, we vary different input variables within the permissible operating range of the heat pump and evaluate COP at the resulting steady-state operating points. It is found that the best set-point for each individual input is located at an extreme...... value of the investigated permissible range, and that the COP optimization is likely to be a convex problem. Further, we exploit this observation to propose a simple offline set-point optimization algorithm, which can be used as an automated assistance for the plant operator to optimize steady...

  10. Free-free absorption coefficients and Gaunt factors for dense hydrogen-like stellar plasma

    Science.gov (United States)

    Srećković, V. A.; Sakan, N.; Šulić, D.; Jevremović, D.; Ignjatović, Lj M.; Dimitrijević, M. S.

    2018-03-01

    In this work, we present a study dedicated to determination of the inverse bremsstrahlung absorption coefficients and the corresponding Gaunt factor of dense hydrogen-like stellar-atmosphere plasmas where electron density and temperature change in a wide range. A method suitable for this wide range is suggested and applied to the inner layers of the solar atmosphere, as well as the plasmas of partially ionized layers of some other stellar atmospheres (for example, some DA and DB white dwarfs) where the electron densities vary from 1014 cm-3 to 1020 cm-3 and temperatures from 6000 K to 300 000 K in the wavelength region of 10 nm ≤ λ ≤ 3000 nm. The results of the calculations are illustrated by the corresponding figures and tables.

  11. Determination of the scattering coefficient of biological tissue considering the wavelength and absorption dependence of the anisotropy factor

    Science.gov (United States)

    Fukutomi, Daichi; Ishii, Katsunori; Awazu, Kunio

    2016-04-01

    The anisotropy factor g, one of the optical properties of biological tissues, has a strong influence on the calculation of the scattering coefficient μ s in inverse Monte Carlo (iMC) simulations. It has been reported that g has the wavelength and absorption dependence; however, few attempts have been made to calculate μ s using g values by taking the wavelength and absorption dependence into account. In this study, the angular distributions of scattered light for biological tissue phantoms containing hemoglobin as a light absorber were measured by a goniometric optical setup at strongly (405 nm) and weakly (664 nm) absorbing wavelengths to obtain g. Subsequently, the optical properties were calculated with the measured values of g by integrating sphere measurements and an iMC simulation, and compared with the results obtained with a conventional g value of 0.9. The μ s values with measured g were overestimated at the strongly absorbing wavelength, but underestimated at the weakly absorbing wavelength if 0.9 was used in the iMC simulation.

  12. Measurements of the Absorption by Auditorium SEATING—A Model Study

    Science.gov (United States)

    BARRON, M.; COLEMAN, S.

    2001-01-01

    One of several problems with seat absorption is that only small numbers of seats can be tested in standard reverberation chambers. One method proposed for reverberation chamber measurements involves extrapolation when the absorption coefficient results are applied to actual auditoria. Model seat measurements in an effectively large model reverberation chamber have allowed the validity of this extrapolation to be checked. The alternative barrier method for reverberation chamber measurements was also tested and the two methods were compared. The effect on the absorption of row-row spacing as well as absorption by small numbers of seating rows was also investigated with model seats.

  13. [Estimation of DOC concentrations using CDOM absorption coefficients: a case study in Taihu Lake].

    Science.gov (United States)

    Jiang, Guang-Jia; Ma, Rong-Hua; Duan, Hong-Tao

    2012-07-01

    Dissolved organic carbon (DOC) is the largest organic carbon stock in water ecosystems, which plays an important role in the carbon cycle in water. Chromophoric dissolved organic matter (CDOM), an important water color variation, is the colored fraction of DOC and its absorption controls the instruction of light under water. The available linkage between DOC concentration and CDOM absorptions enables the determination of DOC accumulations using remote sensing reflectance or radiance in lake waters. The present study explored the multi-liner relationship between CDOM absorptions [a(g) (250) and a(g) (365)] and DOC concentrations in Taihu Lake, based on the available data in 4 cruises (201005, 201101, 201103, 201105) (totally 183 sampling sites). Meanwhile, the results were validated with the data of the experiment carried out from August 29 to September 2, 2011 in Taihu Lake (n = 27). Furthermore, a universal pattern of modeling from remote sensing was built for lake waters. The results demonstrated that this method provided more satisfying estimation of DOC concentrations in Taihu Lake. Except the data obtained in January 2011, the fitted results of which were not conductive to the winter dataset (201101) in Taihu Lake, due to the diverse sources and sinks of DOC and CDOM, the multi-liner relationship was robust for the data collected in the other three cruises (R2 = 0.64, RMSE = 14.31%, n = 164), which was validated using the 201108 sampling dataset (R2 = 0.67, RMSE = 10.58%, n = 27). In addition, the form of the statistic model is universal, to some extent, for other water areas, however, there is difference in the modeling coefficients. Further research should be focused on the parameterization using local data from different lakes, which provides effective methodology for the estimation of DOC concentrations in lakes and other water regions.

  14. The fundamental parameter approach of quantitative XRFA- investigation of photoelectric absorption coefficients

    International Nuclear Information System (INIS)

    Shaltout, A.

    2003-06-01

    The present work describes some actual problems of quantitative x-ray fluorescence analysis by means of the fundamental parameter approach. To perform this task, some of the main parameters are discussed in detail. These parameters are photoelectric cross sections, coherent and incoherent scattering cross sections, mass absorption cross sections and the variation of the x-ray tube voltage. Photoelectric cross sections, coherent and incoherent scattering cross sections and mass absorption cross sections in the energy range from 1 to 300 keV for the elements from Z=1 to 94 considering ten different data bases are studied. These are data bases given by Hubbell, McMaster, Mucall, Scofield, Xcom, Elam, Sasaki, Henke, Cullen and Chantler's data bases. These data bases have been developed also for an application in fundamental parameter programs for quantitative x-ray analysis (Energy Dispersive X-Ray Fluorescence Analysis (EDXRFA), Electron Probe Microanalysis (EPMA), X-Ray Photoelectron Spectroscopy (XPS) and Total Electron Yield (TEY)). In addition a comparison is performed between different data bases. In McMaster's data base, the missing elements (Z=84, 85, 87, 88, 89, 91, and 93) are added by using photoelectric cross sections of Scofield's data base, coherent as well as incoherent scattering cross sections of Elam's data base and the absorption edges of Bearden. Also, the N-fit coefficients of the elements from Z=61 to 69 are wrong in McMaster data base, therefore, linear least squares fits are used to recalculate the N-fit coefficients of these elements. Additionally, in the McMaster tables the positions of the M- and N-edges of all elements with the exception of the M1- and N1- edges are not defined as well as the jump ratio of the edges. In the present work, the M- and N-edges and the related jump ratios are calculated. To include the missing N-edges, Bearden's values of energy edges are used. In Scofield's data base, modifications include check and correction

  15. Measurement of Dynamic Friction Coefficient on the Irregular Free Surface

    International Nuclear Information System (INIS)

    Yeom, S. H.; Seo, K. S.; Lee, J. H.; Lee, K. H.

    2007-01-01

    A spent fuel storage cask must be estimated for a structural integrity when an earthquake occurs because it freely stands on ground surface without a restriction condition. Usually the integrity estimation for a seismic load is performed by a FEM analysis, the friction coefficient for a standing surface is an important parameter in seismic analysis when a sliding happens. When a storage cask is placed on an irregular ground surface, measuring a friction coefficient of an irregular surface is very difficult because the friction coefficient is affected by the surface condition. In this research, dynamic friction coefficients on the irregular surfaces between a concrete cylinder block and a flat concrete slab are measured with two methods by one direction actuator

  16. Automated low energy photon absorption equipment for measuring internal moisture and density distributions of wood samples

    International Nuclear Information System (INIS)

    Tiitta, M.; Olkkonen, H.; Lappalainen, T.; Kanko, T.

    1993-01-01

    Automated equipment for measuring the moisture and density distributions of wood samples was developed. Using a narrow beam of gamma rays, the equipment scans the wood samples, which are placed on the moving belt. The moisture measurement is based on the 241 Am photon absorption technique (59.5 keV), where the difference of the linear absorption coefficients of the moist and dry wood is measured. The method requires no knowledge of the thickness of the specimen. The density estimation method is based on the measurement of the linear attenuation coefficient of wood. Comprehensive software including image processing was developed for treatment of the numerical values of the measurements. (author)

  17. Mass attenuation and mass energy absorption coefficients for 10 keV to 10 MeV photons

    International Nuclear Information System (INIS)

    Joffre, H.; Pages, L.

    1968-01-01

    In this report are given the elements allowing the definition of the values of mass attenuation coefficients and mass energy absorption coefficients for some elements and mixtures, necessary for the study of tissue equivalent materials, for photons in the energy range 10 keV to 10 MeV. After a short reminding of the definitions of the two coefficients, follows, in table form, a compilation of these coefficients, as a function of energy, for simple elements, for certain mineral compounds, organic compounds, gases and particularly of soft tissues. (author) [fr

  18. Mass energy-absorption coefficients and average atomic energy-absorption cross-sections for amino acids in the energy range 0.122-1.330 MeV

    Energy Technology Data Exchange (ETDEWEB)

    More, Chaitali V., E-mail: chaitalimore89@gmail.com; Lokhande, Rajkumar M.; Pawar, Pravina P., E-mail: pravinapawar4@gmail.com [Department of physics, Dr. Babasaheb Ambedkar Marathwada University, Aurangabad 431004 (India)

    2016-05-06

    Mass attenuation coefficients of amino acids such as n-acetyl-l-tryptophan, n-acetyl-l-tyrosine and d-tryptophan were measured in the energy range 0.122-1.330 MeV. NaI (Tl) scintillation detection system was used to detect gamma rays with a resolution of 8.2% at 0.662 MeV. The measured attenuation coefficient values were then used to determine the mass energy-absorption coefficients (σ{sub a,en}) and average atomic energy-absorption cross sections (μ{sub en}/ρ) of the amino acids. Theoretical values were calculated based on XCOM data. Theoretical and experimental values are found to be in good agreement.

  19. DOAS (differential optical absorption spectroscopy) urban pollution measurements

    Science.gov (United States)

    Stevens, Robert K.; Vossler, T. L.

    1991-05-01

    During July and August of 1990, a differential optical absorption spectrometer (DOAS) made by OPSIS Inc. was used to measure gaseous air pollutants over three separate open paths in Atlanta, GA. Over path 1 (1099 m) and path 2 (1824 m), ozone (03), sulfur dioxide (SO2) nitrogen dioxide (NO2), nitrous acid (HNO2) formaldehyde (HCHO), benzene, toluene, and o-xylene were measured. Nitric oxide (NO) and ammonia (NH3) were monitored over path 3 (143 m). The data quality and data capture depended on the compound being measured and the path over which it was measured. Data quality criteria for each compound were chosen such that the average relative standard deviation would be less than 25%. Data capture ranged from 43% for o-xylene for path 1 to 95% for ozone for path 2. Benzene, toluene, and o-xylene concentrations measured over path 2, which crossed over an interstate highway, were higher than concentrations measured over path 1, implicating emissions from vehicles on the highway as a significant source of these compounds. Federal Reference Method (FRN) instruments were located near the DOAS light receivers and measurements of 03, NO2, and NO were made concurrently with the DOAS. Correlation coefficients greater than 0.85 were obtained between the DOAS and FRM's; however, there was a difference between the mean values obtained by the two methods for 03 and NO. A gas chromatograph for measuring volatile organic compounds was operated next to the FRN's. Correlation coefficients of about 0.66 were obtained between the DOAS and GC measurements of benzene and o- xylene. However, the correlation coefficient between the DOAS and GC measurements of toluene averaged only 0.15 for the two DOAS measurement paths. The lack of correlation and other factors indicate the possibility of a localized source of toluene near the GC. In general, disagreements between the two measurement methods could be caused by atmospheric inhomogeneities or interferences in the DOAS and other methods.

  20. Isothermal temperature reactivity coefficient measurement in TRIGA reactor

    International Nuclear Information System (INIS)

    Zagar, T.; Ravnik, M.; Trkov, A.

    2002-01-01

    Direct measurement of an isothermal temperature reactivity coefficient at room temperatures in TRIGA Mark II research reactor at Jozef Stefan Institute in Ljubljana is presented. Temperature reactivity coefficient was measured in the temperature range between 15 o C and 25 o C. All reactivity measurements were performed at almost zero reactor power to reduce or completely eliminate nuclear heating. Slow and steady temperature decrease was controlled using the reactor tank cooling system. In this way the temperatures of fuel, of moderator and of coolant were kept in equilibrium throughout the measurements. It was found out that TRIGA reactor core loaded with standard fuel elements with stainless steel cladding has small positive isothermal temperature reactivity coefficient in this temperature range.(author)

  1. Measurement of mass attenuation coefficients in some Cr, Co and ...

    Indian Academy of Sciences (India)

    The present measured values of mass attenuation coefficients in some compounds at different energies were calculated using eq. (1) and are listed in table 1. The validity of the mixture rule is considered for compounds. The estimated error in the experimentally measured μ/ρ value is <3%. The error arises due to the.

  2. Gamma-ray absorption coefficient of non-homogeneous materials. Part 2. Monte-Carlo calculations and experiment

    International Nuclear Information System (INIS)

    Umiastowski, K.; Buniak, M.; Gyurcsak, J.; Maloszewski, P.

    1976-01-01

    Monte-Carlo calculations and experiments performed in order to verify the analytical formulae developed in the first part of the present paper are discussed. The grain size effect parameter R is determined from the measurements and Monte-Carlo calculations of the absorption coefficient of the granular samples. The dependence of parameter R on the dimensionless grain size Y, obtained in this way is compared with the one calculated from the formulae of Part 1. Good agreement is obtained for all results in a broad range of radiation energies (from 17 keV to 1.33 MeV) and grain sizes (from 40 μm to 4.0 cm). (author)

  3. Limits of the memory coefficient in measuring correlated bursts

    Science.gov (United States)

    Jo, Hang-Hyun; Hiraoka, Takayuki

    2018-03-01

    Temporal inhomogeneities in event sequences of natural and social phenomena have been characterized in terms of interevent times and correlations between interevent times. The inhomogeneities of interevent times have been extensively studied, while the correlations between interevent times, often called correlated bursts, are far from being fully understood. For measuring the correlated bursts, two relevant approaches were suggested, i.e., memory coefficient and burst size distribution. Here a burst size denotes the number of events in a bursty train detected for a given time window. Empirical analyses have revealed that the larger memory coefficient tends to be associated with the heavier tail of the burst size distribution. In particular, empirical findings in human activities appear inconsistent, such that the memory coefficient is close to 0, while burst size distributions follow a power law. In order to comprehend these observations, by assuming the conditional independence between consecutive interevent times, we derive the analytical form of the memory coefficient as a function of parameters describing interevent time and burst size distributions. Our analytical result can explain the general tendency of the larger memory coefficient being associated with the heavier tail of burst size distribution. We also find that the apparently inconsistent observations in human activities are compatible with each other, indicating that the memory coefficient has limits to measure the correlated bursts.

  4. Molar absorption coefficients and stability constants of Zincon metal complexes for determination of metal ions and bioinorganic applications.

    Science.gov (United States)

    Kocyła, Anna; Pomorski, Adam; Krężel, Artur

    2017-11-01

    Zincon (ZI) is one of the most common chromophoric chelating probes for the determination of Zn 2+ and Cu 2+ ions. It is also known to bind other metal ions. However, literature data on its binding properties and molar absorption coefficients are rather poor, varying among publications or determined only in certain conditions. There are no systematic studies on Zn 2+ and Cu 2+ affinities towards ZI performed under various conditions. However, this widely commercially available and inexpensive agent is frequently the first choice probe for the measurement of metal binding and release as well as determination of affinity constants of other ligands/macromolecules of interest. Here, we establish the spectral properties and the stability of ZI and its complexes with Zn 2+ , Cu 2+ , Cd 2+ , Hg 2+ , Co 2+ , Ni 2+ and Pb 2+ at multiple pH values from 6 to 9.9. The obtained results show that in water solution the MZI complex is predominant, but in the case of Co 2+ and Ni 2+ , M(ZI) 2 complexes are also formed. The molar absorption coefficient at 618 nm for ZnZI and 599nm for CuZI complexes at pH7.4 in buffered (I=0.1M) water solutions are 24,200 and 26,100M -1 cm -1 , respectively. Dissociation constants of those complexes are 2.09×10 -6 and 4.68×10 -17 M. We also characterized the metal-assisted Zincon decomposition. Our results provide new and reassessed optical and stability data that are applicable to a wide range of chemical and bioinorganic applications including metal ion detection, and quantification and affinity studies of ligands of interest. Accurate values of molar absorption coefficients of Zincon complex with Zn 2+ , Cd 2+ , Hg 2+ , Co 2+ , Ni 2+ , Cu 2+ , and Pb 2+ for rapid metal ion quantification are provided. Zincon stability constants with Zn 2+ and Cu 2+ in a wide pH range were determined. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. A technique to measure rotordynamic coefficients in hydrostatic bearings

    Science.gov (United States)

    Capaldi, Russell J.

    1993-01-01

    An experimental technique is described for measuring the rotordynamic coefficients of fluid film journal bearings. The bearing tester incorporates a double-spool shaft assembly that permits independent control over the journal spin speed and the frequency of an adjustable-magnitude circular orbit. This configuration yields data that enables determination of the full linear anisotropic rotordynamic coefficient matrices. The dynamic force measurements were made simultaneously with two independent systems, one with piezoelectric load cells and the other with strain gage load cells. Some results are presented for a four-recess, oil-fed hydrostatic journal bearing.

  6. Correlation between oral drug absorption in humans and apparent drug permeability coefficients in human intestinal epithelial (Caco-2) cells

    Energy Technology Data Exchange (ETDEWEB)

    Artursson, P.; Karlsson, J. (Uppsala Univ., (Sweden))

    1991-03-29

    Monolayers of a well differentiated human intestinal epithelial cell line, Caco-2, were used as a model to study passive drug absorption across the intestinal epithelium. Absorption rate constants (expressed as apparent permeability coefficients) were determined for 20 drugs and peptides with different structural properties. The permeability coefficients ranged from approximately 5 x 10{sup {minus} 8} to 5 x 10{sup {minus} 5} cm/s. A good correlation was obtained between data on oral absorption in humans and the results in the Caco-2 model. Drugs that are completely absorbed in humans had permeability coefficients greater than 1 x 10{sup {minus} 6} cm/s. Drugs that are absorbed to greater than 1% but less than 100% had permeability coefficients of 0.1-1.0 x 10{sup {minus} 6} cm/s while drugs and peptides that are absorbed to less than 1% had permeability coefficients of less than or equal to 1 x 10{sup {minus} 7} cm/s. The results indicate that Caco-2 monolayers can be used as a model for studies on intestinal drug absorption.

  7. Comparison of two internationally recognized methods for determining the sound absorption coefficient

    Directory of Open Access Journals (Sweden)

    Drabek Pavel

    2017-01-01

    Full Text Available With today’s growing focus on noise control issues and the emergence of sound quality as an important aspect of product design, acoustic material testing is becoming increasingly relevant to engineers, designers and manufacturers from a broad range of industries. Acoustic material testing is the process by which acoustic characteristics of materials are determined in terms of absorption, reflection, impedance, admittance and transmission loss. Many different methods can be used to determine the acoustic properties of materials. There are standing wave method, two-microphone free field and multimicrophone techniques, reverberation chamber method, in-situ methods and many other alternative methods based on measurement of internal properties of porous materials. The point is that some methods are preferred over others because the environment in which they are measured is closer to real practice. The article deals with the comparison of the results of the measurement in the reverberation chamber and in the interferometer.

  8. Effects of nanosilver on sound absorption coefficients in solid wood species.

    Science.gov (United States)

    Taghiyari, Hamid Reza; Esmailpour, Ayoub; Zolfaghari, Habib

    2016-06-01

    Sound absorption coefficients (ACs) were determined in five solid woods (poplar, beech, walnut, mulberry, and fir) in the longitudinal and tangential directions at four different frequencies of 800, 1000, 2000, and 4000 Hz. The length of the longitudinal and tangential specimens was 50-mm and 10-mm, respectively. Separate sets of specimens were impregnated with either nanosilver suspension or water. The size range of nanoparticles was 30-80 nm. Results showed that sound ACs were lower in longitudinal specimens because sound waves could penetrate the open ends of vessels more easily, being trapped and damped there. Impregnation with both nanosilver suspension and water resulted in a significant decrease in the sound ACs. The decrease in the ACs was due to the collapsing and accumulation of perforation plates and cell parts, blocking the way through which waves could pass through the vessels. This caused higher damping due to a phenomenon called vibration decay. Correlation between gas permeability versus sound AC is significantly dependant on the porous structure of individual specimens.

  9. Experimental Determination of the Molar Absorption Coefficient of n-Hexane Adsorbed on High-Silica Zeolites.

    Science.gov (United States)

    Gatti, Giorgio; Olivas Olivera, Diana F; Sacchetto, Vittoria; Cossi, Maurizio; Braschi, Ilaria; Marchese, Leonardo; Bisio, Chiara

    2017-09-06

    Determination of the molar absorption coefficients of the CH 3 bending mode at ν˜ =1380 cm -1 (ϵ 1380 ) of n-hexane adsorbed from the gas phase on two different dealuminated zeolites is derived by a combination of IR spectroscopy and microgravimetric analysis. High-silica zeolite Y (HSZ-Y) and zeolite ZSM-5 (with SiO 2 /Al 2 O 3 ratios of 200 and 280, respectively) with different textural and surface features are selected to evaluate the effect of the pore structure and architecture on the value of ϵ 1380 of the adsorbed n-hexane. Experimental data indicate that the molecule experiences a different adsorption environment inside zeolites; thus resulting in a significant change of the dipole moment and very different ϵ 1380 values: (0.278±0.018) cm μmol -1 for HSZ-Y and (0.491±0.032) cm μmol -1 for ZSM-5. Experimental data are also supported by computational modeling, which confirms the effect of different matrices on the IR absorption intensity. This study reveals that the use of probe molecules for quantitative measurements of surface sites has to be judiciously adopted, especially if adsorption occurs in the restricted spaces of microporous materials. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The use of a reference absorber for absorption measurements in a reverberation chamber

    DEFF Research Database (Denmark)

    Nolan, Melanie; Vercammen, Martijn; Jeong, Cheol-Ho

    2014-01-01

    will be used for qualification of the room and correction of the results. The present research establishes the requirements for a proper design of such an absorber and its reference absorption data. The diffuse field factor was used to quantify the diffuse sound field in several reverberation rooms......The statistical incidence absorption coefficient is measured in a reverberation room according to ISO 354. This absorption coefficient is referred to as Sabine absorption coefficient, which assumes the chambe r to be completely diffuse. It is known that the reproducibility of these results is poor...... and the differences in the results between laboratories are much larger than can be accepted from a jurisdictional point of view. Actions should therefore be taken to reduce the spread. The intention of this paper is to set requirements on the diffusivity of the sound field and to apply a reference absorber, which...

  11. ABSORPTION MEASURE DISTRIBUTION IN Mrk 509

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, T. P.; Różańska, A.; Sobolewska, M. [Nicolaus Copernicus Astronomical Center, Polish Academy of Sciences, Bartycka 18, 00-716, Warsaw (Poland); Czerny, B., E-mail: tek@camk.edu.pl [Center for Theoretical Physics, Polish Academy of Sciences, Al. Lotnikow 32/46 02-668, Warsaw (Poland)

    2015-12-20

    In this paper we model the observed absorption measure distribution (AMD) in Mrk 509, which spans three orders of magnitude in ionization level with a single-zone absorber in pressure equilibrium. AMD is usually constructed from observations of narrow absorption lines in radio-quiet active galaxies with warm absorbers. We study the properties of the warm absorber in Mrk 509 using recently published broadband spectral energy distribution observed with different instruments. This spectrum is an input in radiative transfer computations with full photoionization treatment using the titan code. We show that the simplest way to fully reproduce the shape of AMD is to assume that the warm absorber is a single zone under constant total pressure. With this assumption, we found theoretical AMD that matches the observed AMD determined on the basis of the 600 ks reflection grating spectrometer XMM-Newton spectrum of Mrk 509. The softness of the source spectrum and the important role of the free–free emission breaks the usual degeneracy in the ionization state calculations, and the explicit dependence of the depths of AMD dips on density open a new path to the density diagnostic for the warm absorber. In Mrk 509, the implied density is of the order of 10{sup 8} cm{sup −3}.

  12. Using Plasticine (TM) to Measure the Rolling Friction Coefficient.

    Science.gov (United States)

    Castellvi, Francesc; And Others

    1995-01-01

    Presents an experiment that makes manifest the energy lost to friction of an iron ball moving along an inclined iron rail, which allows students to compute the rolling friction coefficient. Uses a method based on measurement of deformation produced in a piece of Plasticine by an inelastic collision with the ball and combines mechanical concepts…

  13. Measurements of gaseous multiplication coefficient in pure isobutane

    International Nuclear Information System (INIS)

    Lima, Iara Batista de

    2010-01-01

    In this work it is presented measurements of gaseous multiplication coefficient (α) in pure isobutane obtained with a parallel plate chamber, protected against discharges by one electrode (anode) of high resistivity glass (ρ = 2 x 10 12 Ω.cm). The method applied was the Pulsed Townsend, where the primary ionization is produced through the incidence of a nitrogen laser beam onto a metallic electrode (cathode). The electric currents measured with the chamber operating in both ionization and avalanche regimes were used to calculate the gaseous multiplication coefficient by the solution of the Townsend equation for uniform electric fields. The validation of the technique was provided by the measurements of gaseous multiplication coefficient in pure nitrogen, a widely studied gas, which has well-established data in literature. The α coefficients in isobutane were measured as a function of the reduced electric field in the range of 139Td up to 208Td. The obtained values were compared with those simulated by Imonte software (version 4.5) and the only experimental results available in the literature, recently obtained in our group. This comparison showed that the results are concordant within the experimental errors. (author)

  14. Methods for measuring diffusion coefficients of radon in building materials

    NARCIS (Netherlands)

    Cozmuta, [No Value; van der Graaf, ER

    2001-01-01

    Two methods for determining the Rn-222 diffusion coefficient in concrete are presented. Experimentally, the flush and adsorption technique to measure radon release rates underlines both methods. Theoretically, the first method was developed fur samples of cubical geometry. The radon diffusion

  15. Plasma sheath properties calculated using measured secondary electron emission coefficients

    International Nuclear Information System (INIS)

    Pedgley, J.M.; McCracken, G.M.

    1993-01-01

    Measurements of secondary electron emission (SEE) are presented for graphite, hydrogen-implanted graphite and an amorphous graphite (a-C:H) carbon layer, over a wide range of energies and angles of incidence. These data have been integrated over a Maxwellian velocity distribution to simulate the effect of SEE due to plasma electrons. The SEE yields have then been used to calculate plasma sheath potentials, sheath heat transmission coefficients and sputtering yields for a range of ions as a function of plasma temperature. The increased SEE yield with temperature reduces the normalized sheath potential and increases the sheath transmission coefficient markedly. The role of space charge in the sheath is discussed. (Author)

  16. A new technique of measuring trace absorption of optical thin films

    International Nuclear Information System (INIS)

    Apparao, K.V.S.R.; Sahoo, N.K.

    1993-01-01

    An instrument to measure trace absorption of optical thin films is indigenously developed using a novel technique. The instrument based on calorimetric principle measures the temperature rise and absorption of a sample simultaneously by two independent techniques. Such a dual technique feature enables one to measure the sample absorption with the first technique and simultaneously check the result with the second technique. The instrument can be used to measure trace absorption of dielectric optical thin films in UV, visible and near-IR spectral regions. Using the new instrument the absorption constant β and extinction coefficient k of Sb 2 O 3 and ZrO 2 films at 308 and 337 nm are measured successfully and reported for the first time. (author). 16 refs., 6 figs., 3 tabs

  17. Pancreatic Enzyme Therapy and Coefficient of Fat Absorption in Children and AdolReplacement escents With Cystic Fibrosis

    NARCIS (Netherlands)

    Woestenenk, Janna W; van der Ent, Cornelis K.; Houwen, Roderick H J; van der Ent, CK

    Objectives: Pancreatic enzyme replacement therapy (PERT) is the proven therapy to substantially reduce fat malabsorption in patients with cystic fibrosis (CF). Few details of the daily practice regarding PERT and the resulting coefficient of fat absorption (CFA) are known. We therefore recorded the

  18. An experimental assembly for precise measurement of thermal accommodation coefficients

    Science.gov (United States)

    Trott, Wayne M.; Castañeda, Jaime N.; Torczynski, John R.; Gallis, Michael A.; Rader, Daniel J.

    2011-03-01

    An experimental apparatus has been developed to determine thermal accommodation coefficients for a variety of gas-surface combinations. Results are obtained primarily through measurement of the pressure dependence of the conductive heat flux between parallel plates separated by a gas-filled gap. Measured heat-flux data are used in a formula based on Direct Simulation Monte Carlo (DSMC) simulations to determine the coefficients. The assembly also features a complementary capability for measuring the variation in gas density between the plates using electron-beam fluorescence. Surface materials examined include 304 stainless steel, gold, aluminum, platinum, silicon, silicon nitride, and polysilicon. Effects of gas composition, surface roughness, and surface contamination have been investigated with this system; the behavior of gas mixtures has also been explored. Without special cleaning procedures, thermal accommodation coefficients for most materials and surface finishes were determined to be near 0.95, 0.85, and 0.45 for argon, nitrogen, and helium, respectively. Surface cleaning by in situ argon-plasma treatment reduced coefficient values by up to 0.10 for helium and by ˜0.05 for nitrogen and argon. Results for both single-species and gas-mixture experiments compare favorably to DSMC simulations.

  19. An experimental assembly for precise measurement of thermal accommodation coefficients.

    Science.gov (United States)

    Trott, Wayne M; Castañeda, Jaime N; Torczynski, John R; Gallis, Michael A; Rader, Daniel J

    2011-03-01

    An experimental apparatus has been developed to determine thermal accommodation coefficients for a variety of gas-surface combinations. Results are obtained primarily through measurement of the pressure dependence of the conductive heat flux between parallel plates separated by a gas-filled gap. Measured heat-flux data are used in a formula based on Direct Simulation Monte Carlo (DSMC) simulations to determine the coefficients. The assembly also features a complementary capability for measuring the variation in gas density between the plates using electron-beam fluorescence. Surface materials examined include 304 stainless steel, gold, aluminum, platinum, silicon, silicon nitride, and polysilicon. Effects of gas composition, surface roughness, and surface contamination have been investigated with this system; the behavior of gas mixtures has also been explored. Without special cleaning procedures, thermal accommodation coefficients for most materials and surface finishes were determined to be near 0.95, 0.85, and 0.45 for argon, nitrogen, and helium, respectively. Surface cleaning by in situ argon-plasma treatment reduced coefficient values by up to 0.10 for helium and by ∼0.05 for nitrogen and argon. Results for both single-species and gas-mixture experiments compare favorably to DSMC simulations.

  20. A technique for measuring dynamic friction coefficient under impact loading.

    Science.gov (United States)

    Lin, Y L; Qin, J G; Chen, R; Zhao, P D; Lu, F Y

    2014-09-01

    We develop a novel setup based on the split Hopkinson pressure bar technique to test the dynamic friction coefficient under impact loading. In the setup, the major improvement is that the end of the incident bar near the specimen is wedge-shaped, which results in a combined compressive and shear loading applied to the specimen. In fact, the shear loading is caused by the interfacial friction between specimen and bars. Therefore, when the two loading force histories are measured, the friction coefficient histories can be calculated without any assumptions and theoretical derivations. The geometry of the friction pairs is simple, and can be either cuboid or cylindrical. Regarding the measurements, two quartz transducers are used to directly record the force histories, and an optical apparatus is designed to test the interfacial slip movement. By using the setup, the dynamic friction coefficient of PTFE/aluminum 7075 friction pairs was tested. The time resolved dynamic friction coefficient and slip movement histories were achieved. The results show that the friction coefficient changes during the loading process, the average data of the relatively stable flat plateau section of the friction coefficient curves is 0.137, the maximum normal pressure is 52 MPa, the maximum relative slip velocity is 1.5 m/s, and the acceleration is 8400 m(2)/s. Furthermore, the friction test was simulated using an explicit FEM code LS-DYNA. The simulation results showed that the constant pressure and slip velocity can both be obtained with a wide flat plateau incident pulse. For some special friction pairs, normal pressure up to a few hundred MPa, interfacial slip velocities up to 10 m/s, and slip movement up to centimeter-level can be expected.

  1. Measurements of the Drag Coefficient of Simulated Micrometeoroids

    Science.gov (United States)

    DeLuca, M.; Munsat, T.; Sternovsky, Z.

    2017-12-01

    The dust accelerator facility operated at the University of Colorado is used to simulate meteoric ablation, including measuring the ionization efficiency over a wide range of velocities (e.g., DeLuca et al., Planet. Space Sci., submitted, 2017). This presentation reports on the most recent experimental measurements of the drag coefficient that determines the particles' slowdown from their frictional interaction with the atmosphere. The measurements indicate that meteors experience considerably more slowdown than usually assumed. The simulated meteors consisted of submicron sized aluminum particles shot into an air chamber held at 200 mTorr pressure at velocities between 1 - 10 km/s using the dust accelerator and meteor ablation facility. The slowdown is calculated from precise timing measurements made using pickup tube detectors placed upstream and near the entrance to the air chamber, and an impact detector inside the air chamber at the downstream end of the chamber. Supporting modeling calculations show that the particles have little or no mass loss during their interaction with air and thus constant radius can be assumed. Preliminary results for the drag coefficient calculated from these timing measurements reveal that the aluminum particles have a drag coefficient of 1.51 ± 0.24 in air, which is higher than typically assumed in meteoric ablation models (usually 0.5 to 1), indicating that meteors may experience more air drag than previously assumed. More detailed measurements over a wider parameter range are underway.

  2. A method to determine the acoustic reflection and absorption coefficients of porous media by using modal dispersion in a waveguide.

    Science.gov (United States)

    Prisutova, Jevgenija; Horoshenkov, Kirill; Groby, Jean-Philippe; Brouard, Bruno

    2014-12-01

    The measurement of acoustic material characteristics using a standard impedance tube method is generally limited to the plane wave regime below the tube cut-on frequency. This implies that the size of the tube and, consequently, the size of the material specimen must remain smaller than a half of the wavelength. This paper presents a method that enables the extension of the frequency range beyond the plane wave regime by at least a factor of 3, so that the size of the material specimen can be much larger than the wavelength. The proposed method is based on measuring of the sound pressure at different axial locations and applying the spatial Fourier transform. A normal mode decomposition approach is used together with an optimization algorithm to minimize the discrepancy between the measured and predicted sound pressure spectra. This allows the frequency and angle dependent reflection and absorption coefficients of the material specimen to be calculated in an extended frequency range. The method has been tested successfully on samples of melamine foam and wood fiber. The measured data are in close agreement with the predictions by the equivalent fluid model for the acoustical properties of porous media.

  3. Parameterization of the chlorophyll a-specific in vivo light absorption coefficient covering estuarine, coastal and oceanic waters

    DEFF Research Database (Denmark)

    Stæhr, P. A.; Markager, S. S.

    2004-01-01

    We evaluated models predicting the spectral chlorophyll-a (Chl a)-specific absorption coefficient (a*ph (¿)) from Chl a concentration [Chl a] on the basis of 465 phytoplankton absorption spectra collected in estuarine, coastal and oceanic waters. A power model on ln-transformed data provided.......015 m2 mg-1 Chl a) at 440 nm, the peak absorption of Chl a in the blue part of the spectrum. The variations in the modelled a*ph spectra were within realistic predictions of a*ph (¿) and the model satisfactorily reproduced the spectral flattening with increasing [Chl a]. The parameterization of a......*ph (¿) confirmed the indirect dependency of a*ph (¿) on [Chl a] through co-variations between [Chl a] with pigment packaging and pigment composition. Although pigment packaging determined the spectral flattening, analysis of absorption ratios revealed a systematic change in pigment composition with profound...

  4. Linear thermal expansion coefficient measurement technology in hot cell

    International Nuclear Information System (INIS)

    Park, Dae Gyu; Choo, Yong Sun; Ahn, Sang Bok; Hong, Kwon Pyo; Lee, K. S.

    1998-06-01

    To establish linear thermal expansion coefficient measurement technology in hot cell, we reviewed and evaluated various measuring technology by paper and these were compared with the data produced with pre-installed dilatometer in hot cell. Detailed contents are as follows; - The theory of test. - Review of characteristics for various measurement technology and compatibility with hot cell. - Review of standard testing regulations(ASTM). - System calibration of pre-installed dilatometer. - Performance test of pre-installed dilatometer. (author). 12 refs., 15 tabs., 8 figs

  5. Estimating local heat transfer coefficients from thin wall temperature measurements

    Science.gov (United States)

    Gazizov, I. M.; Davletshin, I. A.; Paereliy, A. A.

    2017-09-01

    An approach to experimental estimation of local heat transfer coefficient on a plane wall has been described. The approach is based on measurements of heat-transfer fluid and wall temperatures during some certain time of wall cooling. The wall was a thin plate, a printed circuit board, made of composite epoxy material covered with a copper layer. The temperature field can be considered uniform across the plate thickness when heat transfer is moderate and thermal resistance of the plate in transversal direction is low. This significantly simplifies the heat balance written for the wall sections that is used to estimate the heat transfer coefficient. The copper layer on the plate etched to form a single strip acted as resistance thermometers that measured the local temperature of the wall.

  6. Measurement of the distribution coefficient between soil and Cesium-137

    International Nuclear Information System (INIS)

    Tejada V, S.; Hernandez P, M.

    1996-01-01

    The measurement of the distribution coefficient of Cs-137 is currently performed by batch method between radioisotope solution and which was collected from the Mexican Disposal Site, near the town of Maquixco, in the state of Mexico. The Kd values were obtained in activity concentration of Cs-137 of 100 Bq. The solution is shaken for seven days at 25 o C when the maximum amount of radionuclide is absorbed by the soil. The radionuclide in solution is measured by gamma spectrometry. The results obtained from batch method show that the distribution coefficients were from 144 to 660 ml/g for fine soil particles. This work is currently done as part of the site characterization studies for the disposal of low level rad-waste. (authors). 10 refs., 2 tabs

  7. Determination of electromagnetic absorption parameters by reflection measurements

    International Nuclear Information System (INIS)

    Vittitoe, C.N.

    1975-09-01

    The method described is for determining the electromagnetic absorption parameters of a material by measuring the optical reflection from a thick sample. With linearly polarized incident light (both perpendicular to and parallel to the plane of incidence), the ratio of the reflected intensities at three or more angles of incidence offers promise for determining the complex index of refraction of a material for a broad range of parameter values. The method may be applicable to molten materials, such as UO 2 , where high temperatures cause corrosion and containment difficulties. A method is given for extending the data to neighboring frequencies. Use of the method was successful for all portions of the complex index of refraction plane except for small values of the extinction coefficient

  8. Determination of the Rb atomic number density in dense rubidium vapors by absorption measurements of Rb2 triplet bands

    International Nuclear Information System (INIS)

    Horvatic, Vlasta; Veza, Damir; Niemax, Kay; Vadla, Cedomil

    2008-01-01

    A simple and accurate way of determining atom number densities in dense rubidium vapors is presented. The method relies on the experimental finding that the reduced absorption coefficients of the Rb triplet satellite bands between 740 nm and 750 nm and the triplet diffuse band between 600 nm and 610 nm are not temperature dependent in the range between 600 K and 800 K. Therefore, the absolute values of the reduced absorption coefficients of these molecular bands can provide accurate information about atomic number density of the vapor. The rubidium absorption spectrum was measured by spatially resolved white-light absorption in overheated rubidium vapor generated in a heat pipe oven. The absolute values for the reduced absorption coefficients of the triplet bands were determined at lower vapor densities, by using an accurate expression for the reduced absorption coefficient in the quasistatic wing of the Rb D1 line, and measured triplet satellite bands to the resonance wing optical depth ratio. These triplet satellite band data were used to calibrate in absolute scale the reduced absorption coefficients of the triplet diffuse band at higher temperatures. The obtained values for the reduced absorption coefficient of these Rb molecular features can be used for accurate determination of rubidium atomic number densities in the range from about 5 x 10 16 cm -3 to 1 x 10 18 cm -3

  9. Measurement and modeling of interface heat transfer coefficients

    International Nuclear Information System (INIS)

    Rollett, A.D.; Lewis, H.D.; Dunn, P.S.

    1985-01-01

    The results of preliminary work on the modeling and measurement of the heat transfer coefficients of metal/mold interfaces is reported. The system investigated is the casting of uranium in graphite molds. The motivation for the work is primarily to improve the accuracy of process modeling of prototype mold designs at the Los Alamos Foundry. The evolution in design of a suitable mold for unidirectional solidification is described, illustrating the value of simulating mold designs prior to use. Experiment indicated a heat transfer coefficient of 2 kW/m 2 /K both with and without superheat. It was possible to distinguish between solidification due to the mold and that due to radiative heat loss. This permitted an experimental estimate of the emissivity, epsilon = 0.2, of the solidified metal

  10. Measurement of particle transport coefficients on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Luke, T.C.T.

    1994-10-01

    The goal of this thesis was to study the behavior of the plasma transport during the divertor detachment in order to explain the central electron density rise. The measurement of particle transport coefficients requires sophisticated diagnostic tools. A two color interferometer system was developed and installed on Alcator C-Mod to measure the electron density with high spatial ({approx} 2 cm) and high temporal ({le} 1.0 ms) resolution. The system consists of 10 CO{sub 2} (10.6 {mu}m) and 4 HeNe (.6328 {mu}m) chords that are used to measure the line integrated density to within 0.08 CO{sub 2} degrees or 2.3 {times} 10{sup 16}m{sup {minus}2} theoretically. Using the two color interferometer, a series of gas puffing experiments were conducted. The density was varied above and below the threshold density for detachment at a constant magnetic field and plasma current. Using a gas modulation technique, the particle diffusion, D, and the convective velocity, V, were determined. Profiles were inverted using a SVD inversion and the transport coefficients were extracted with a time regression analysis and a transport simulation analysis. Results from each analysis were in good agreement. Measured profiles of the coefficients increased with the radius and the values were consistent with measurements from other experiments. The values exceeded neoclassical predictions by a factor of 10. The profiles also exhibited an inverse dependence with plasma density. The scaling of both attached and detached plasmas agreed well with this inverse scaling. This result and the lack of change in the energy and impurity transport indicate that there was no change in the underlying transport processes after detachment.

  11. Measurement of particle transport coefficients on Alcator C-Mod

    International Nuclear Information System (INIS)

    Luke, T.C.T.

    1994-10-01

    The goal of this thesis was to study the behavior of the plasma transport during the divertor detachment in order to explain the central electron density rise. The measurement of particle transport coefficients requires sophisticated diagnostic tools. A two color interferometer system was developed and installed on Alcator C-Mod to measure the electron density with high spatial (∼ 2 cm) and high temporal (≤ 1.0 ms) resolution. The system consists of 10 CO 2 (10.6 μm) and 4 HeNe (.6328 μm) chords that are used to measure the line integrated density to within 0.08 CO 2 degrees or 2.3 x 10 16 m -2 theoretically. Using the two color interferometer, a series of gas puffing experiments were conducted. The density was varied above and below the threshold density for detachment at a constant magnetic field and plasma current. Using a gas modulation technique, the particle diffusion, D, and the convective velocity, V, were determined. Profiles were inverted using a SVD inversion and the transport coefficients were extracted with a time regression analysis and a transport simulation analysis. Results from each analysis were in good agreement. Measured profiles of the coefficients increased with the radius and the values were consistent with measurements from other experiments. The values exceeded neoclassical predictions by a factor of 10. The profiles also exhibited an inverse dependence with plasma density. The scaling of both attached and detached plasmas agreed well with this inverse scaling. This result and the lack of change in the energy and impurity transport indicate that there was no change in the underlying transport processes after detachment

  12. Calculus of the amplification and absorption coefficients of the electromagnetic waves in a cylindrical over dense plasma

    International Nuclear Information System (INIS)

    Arzate P, N.

    1994-01-01

    Based on the fundamental theory of cylindrical waveguides and resonant cavities, the main characteristic parameters of the microwave plasma source reported in [1] are calculated. The absorption coefficient of an electromagnetic wave which is excited in H 11 mode in a cylindrical waveguide that contains a cold, inhomogeneous and magnetized plasma column is determined by using the perturbative method describe in [2]. In similar way, due to the presence of the plasma column, the shifts of the resonant frequency and of the inverse of the quality of a cylindrical resonant cavity where a TE 111 mode is oscilating are obtained. Finally, based on the linear theory, an analysis of the penetration of electromagnetic fields in a semi-bounded plasma and a plasma layer is done. The reflexion, transmission and absorption coefficients of H waves for the cases of an isotropic homogeneous and weak inhomogeneous plasma are calculated. (Author)

  13. Remote Sensing of the Absorption Coefficients and Chlorophyll a Concentration in the U.S. Southern Middle Atlantic Bight from SeaWiFS and MODIS-Aqua

    Science.gov (United States)

    Pan, Xiaoju; Mannino, Antonio; Russ, Mary E.; Hooker, Stanford B.

    2008-01-01

    At present, satellite remote sensing of coastal water quality and constituent concentration is subject to large errors as compared to the capability of satellite sensors in oceanic waters. In this study, field measurements collected on a series of cruises within U.S. southern Middle Atlantic Bight (SMAB) were applied to improve retrievals of satellite ocean color products in order to examine the factors that regulate the bio-optical properties within the continental shelf waters of the SMAB. The first objective was to develop improvements in satellite retrievals of absorption coefficients of phytoplankton (a(sub ph)), colored dissolved organic matter (CDOM) (a(sub g)), non-pigmented particles (a(sub d)), and non-pigmented particles plus CDOM (a(sub dg)), and chlorophyll a concentration ([Chl_a]). Several algorithms were compared to derive constituent absorption coefficients from remote sensing reflectance (R(sub rs)) ratios. The validation match-ups showed that the mean absolute percent differences (MAPD) were typically less than 35%, although higher errors were found for a(sub d) retrievals. Seasonal and spatial variability of satellite-derived absorption coefficients and [Chl_a] was apparent and consistent with field data. CDOM is a major contributor to the bio-optical properties of the SMAB, accounting for 35-70% of total light absorption by particles plus CDOM at 443 nm, as compared to 30-45% for phytoplankton and 0-20% for non-pigmented particles. The overestimation of [Chl_a] from the operational satellite algorithms may be attributed to the strong CDOM absorption in this region. River discharge is important in controlling the bio-optical environment, but cannot explain all of the regional and seasonal variability of biogeochemical constituents in the SMAB.

  14. Molecular design for improved photovoltaic efficiency: band gap and absorption coefficient engineering

    KAUST Repository

    Mondal, Rajib

    2009-01-01

    Removing the adjacent thiophene groups around the acceptor core in low band gap polymers significantly enhances solar cell efficiency through increasing the optical absorption and raising the ionization potential of the polymer. © 2009 The Royal Society of Chemistry.

  15. Measuring oblique incidence sound absorption using a local plane wave assumption

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, Andries

    2014-01-01

    In this paper a method for the measurement of the oblique incidence sound absorption coefficient is presented. It is based on a local field assumption, in which the acoustic field is locally approximated by one incident- and one specularly reflected plane wave. The amplitudes of these waves can be

  16. Ultrasonic absorption

    International Nuclear Information System (INIS)

    Beyer, R.T.

    1985-01-01

    The paper reviews studies of ultrasonic absorption in liquid alkali metals. The experimental methods to measure the absorption coefficients are briefly described. Experimental results reported for the liquid metals: sodium, potassium, rubidium and caesium, at medium temperatures, are presented, as well as data for liquid alloys. Absorption losses due to the presence of an external magnetic field, and the effects of viscosity on the absorption in metals, are both discussed. (U.K.)

  17. Pseudopotential calculations and photothermal lensing measurements of two-photon absorption in solids

    International Nuclear Information System (INIS)

    White, W.T. III.

    1985-01-01

    We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in order to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs

  18. Pseudopotential calculations and photothermal lensing measurements of two-photon absorption in solids

    Energy Technology Data Exchange (ETDEWEB)

    White, W.T. III

    1985-11-04

    We have studied two-photon absorption in solids theoretically and experimentally. We have shown that it is possible to use accurate band structure techniques to compute two-photon absorption spectra within 15% of measured values in a wide band-gap material, ZnS. The empirical pseudopotential technique that we used is significantly more accurate than previous models of two-photon absorption in zinc blende materials, including present tunneling theories (which are essentially parabolic-band results in disguise) and the nonparabolic-band formalism of Pidgeon et al. and Weiler. The agreement between our predictions and previous measurements allowed us to use ZnS as a reference material in order to validate a technique for measuring two-photon absorption that was previously untried in solids, pulsed dual-beam thermal lensing. With the validated technique, we examined nonlinear absorption in one other crystal (rutile) and in several glasses, including silicates, borosilicates, and one phosphate glass. Initially, we believed that the absorption edges of all the materials were comparable; however, subsequent evidence suggested that the effective band-gap energies of the glasses were above the energy of two photons in our measurement. Therefore, we attribute the nonlinear absorption that we observed in glasses to impurities or defects. The measured nonlinear absorption coefficients were of the order of a few cm/TW in the glasses and of the order of 10 cm/GW in the crystals, four orders of magnitude higher than in glasses. 292 refs.

  19. Measurement of the temperature coefficient of ratio transformers

    Science.gov (United States)

    Briggs, Matthew E.; Gammon, Robert W.; Shaumeyer, J. N.

    1993-01-01

    We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

  20. Measurements of the gaseous multiplication coefficient in pure isobutane

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Iara B.; Vivaldini, Tulio C.; Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B., E-mail: ccbueno@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ridenti, Marco A.; Pascholati, Paulo R. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Fisica. Lab. do Acelerador Linear; Fonte, Paulo; Mangiarotti, Alessio [Universidade de Coimbra (Portugal). Dept de Fisica. Lab. de Instrumentacao e Fisica Experimental de Particulas

    2009-07-01

    In this work we present the preliminary studies of the first Townsend coefficient behavior in isobutane for reduced electric fields ranging from 173 Td up to 281 Td by means of signal amplitude analysis. The measurements were based on the Pulsed Townsend technique. The experimental setup consists of two parallel plates housed in a stainless steel chamber at gas flow regime. In our configuration, the primary electrons are produced by irradiating the cathode with a fast nitrogen laser (700 ps pulse duration). In order to validate the technique and to analyze effects of non-uniformity, results for nitrogen are also presented. (author)

  1. Measurements of the gaseous multiplication coefficient in pure isobutane

    International Nuclear Information System (INIS)

    Lima, Iara B.; Vivaldini, Tulio C.; Goncalves, Josemary A.C.; Botelho, Suzana; Tobias, Carmen C.B.; Ridenti, Marco A.; Pascholati, Paulo R.; Fonte, Paulo; Mangiarotti, Alessio

    2009-01-01

    In this work we present the preliminary studies of the first Townsend coefficient behavior in isobutane for reduced electric fields ranging from 173 Td up to 281 Td by means of signal amplitude analysis. The measurements were based on the Pulsed Townsend technique. The experimental setup consists of two parallel plates housed in a stainless steel chamber at gas flow regime. In our configuration, the primary electrons are produced by irradiating the cathode with a fast nitrogen laser (700 ps pulse duration). In order to validate the technique and to analyze effects of non-uniformity, results for nitrogen are also presented. (author)

  2. Absorption Measurements of Periodically Poled Potassium Titanyl Phosphate (PPKTP at 775 nm and 1550 nm

    Directory of Open Access Journals (Sweden)

    Jessica Steinlechner

    2013-01-01

    Full Text Available The efficient generation of second-harmonic light and squeezed light requires non-linear crystals that have low absorption at the fundamental and harmonic wavelengths. In this work the photo-thermal self-phase modulation technique is exploited to measure the absorption coefficient of periodically poled potassium titanyl phosphate (PPKTP at 1,550 nm and 775 nm. Themeasurement results are (84±40 ppm/cmand (127±24 ppm/cm, respectively. We conclude that the performance of state-of-the-art frequency doubling and squeezed light generation in PPKTP is not limited by absorption.

  3. Apparent diffusion coefficient measurements in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Ohshita, T.; Oka, M.; Imon, Y.; Yamaguchi, S.; Mimori, Y.; Nakamura, S. [Hiroshima Univ. (Japan). School of Medicine

    2000-09-01

    We measured the apparent diffusion coefficient (ADC), using diffusion-weighted imaging (DWI) and signal intensity on T2-weighted MRI in the cerebral white matter of patients with progressive supranuclear palsy (PSP) and age-matched normal subjects. In PSP, ADC in the prefrontal and precentral white matter was significantly higher than in controls. There was no significant difference in signal intensity on T2-weighted images. The ADC did correlate with signal intensity. The distribution of the elevation of ADC may be the consequence of underlying pathological changes, such as neurofibrillary tangles or glial fibrillary tangles in the cortex. Our findings suggest that ADC measurement might be useful for demonstrating subtle neuropathological changes. (orig.)

  4. Estimation of the molar absorption coefficient of copper salicylate within the spectral range 300-350 nm

    Science.gov (United States)

    Lavrik, N. L.; Mulloev, N. U.

    2017-12-01

    Additional absorption was detected in absorption spectra within the range 300-350 nm after addition of copper sulfate CuSO4(aq) to a solution of sodium salicylate NaНSal (рН = 7.8). The additional maximum absorption was observed at 320 nm. Assuming that the additional absorption depends on the formation of copper salicylate CuSal, the molar absorption coefficient εCuSal of this complex was determined to be (3.8 ± 0.02) · 103 М- 1 сm- 1. This value is almost equal to that of monoanion HSal-, εHSal - = (3.6 ± 0.04) · 103 М- 1 сm- 1, and is 2.5 times as much as εFe3 + HSal - = (1.55 ± 0.05) · 103 М- 1 сm- 1 for iron salicylate. The difference in εCuSal and εFe3 + HSal - is due to the difference in the initial electron states of Cu2 + and Fe3 + ions that have the d9 and d5 configurations, respectively.

  5. Measurements of Narrow Mg II Associated Absorption Doublets with ...

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... The measurement of the variations of absorption lines over time is a good method to study the physical conditions of absorbers. In this paper, we measure the variations of the line strength of 36 narrow Mg II2796, 2803 associated absorption doublets, which are imprinted on 31 quasar spectra with two ...

  6. Soret forced Rayleigh scattering instrument for simultaneous detection of two-wavelength signals to measure Soret coefficient and thermodiffusion coefficient in ternary mixtures

    Science.gov (United States)

    Matsuura, H.; Nagasaka, Y.

    2018-02-01

    We describe an instrument for the measurement of the Soret and thermodiffusion coefficients in ternary systems based on the transient holographic grating technique, which is called Soret forced Rayleigh scattering (SFRS) or thermal diffusion forced Rayleigh scattering (TDFRS). We integrated the SFRS technique and the two-wavelength detection technique, which enabled us to obtain two different signals to determine the two independent Soret coefficients and thermodiffusion coefficients in ternary systems. The instrument has been designed to read the mass transport simultaneously by two-wavelength lasers with wavelengths of λ = 403 nm and λ = 639 nm. The irradiation time of the probing lasers is controlled to reduce the effect of laser absorption to the sample with dye (quinizarin), which is added to convert the interference pattern of the heating laser of λ = 532 nm to the temperature grating. The result of the measurement of binary benchmark mixtures composed of 1,2,3,4-tetrahydronaphthalene (THN), isobutylbenzene (IBB), and n-dodecane (nC12) shows that the simultaneous two-wavelength observation of the Soret effect and the mass diffusion are adequately performed. To evaluate performance in the measurement of ternary systems, we carried out experiments on the ternary benchmark mixtures of THN/IBB/nC12 with the mass fractions of 0.800/0.100/0.100 at a temperature of 298.2 K. The Soret coefficient and thermodiffusion coefficient agreed with the ternary benchmark values within the range of the standard uncertainties (23% for the Soret coefficient of THN and 30% for the thermodiffusion coefficient of THN).

  7. Verification of the semiempirical formulae for γ-ray absorption coefficients

    International Nuclear Information System (INIS)

    Chikkur, G.C.; Hanagodimath, S.M.

    1989-01-01

    The total absorption cross-section have been calculated for power energy γ-rays using the semiempirical formulae put forth by Massaro et al (1982) at three different energies, and the values are compared with the experimental values of Smiles et al (1982). There is a good agreement between experimental and calculated values. (author). 7 refs

  8. Pendulum mass affects the measurement of articular friction coefficient.

    Science.gov (United States)

    Akelman, Matthew R; Teeple, Erin; Machan, Jason T; Crisco, Joseph J; Jay, Gregory D; Fleming, Braden C

    2013-02-01

    Friction measurements of articular cartilage are important to determine the relative tribologic contributions made by synovial fluid or cartilage, and to assess the efficacy of therapies for preventing the development of post-traumatic osteoarthritis. Stanton's equation is the most frequently used formula for estimating the whole joint friction coefficient (μ) of an articular pendulum, and assumes pendulum energy loss through a mass-independent mechanism. This study examines if articular pendulum energy loss is indeed mass independent, and compares Stanton's model to an alternative model, which incorporates viscous damping, for calculating μ. Ten loads (25-100% body weight) were applied in a random order to an articular pendulum using the knees of adult male Hartley guinea pigs (n=4) as the fulcrum. Motion of the decaying pendulum was recorded and μ was estimated using two models: Stanton's equation, and an exponential decay function incorporating a viscous damping coefficient. μ estimates decreased as mass increased for both models. Exponential decay model fit error values were 82% less than the Stanton model. These results indicate that μ decreases with increasing mass, and that an exponential decay model provides a better fit for articular pendulum data at all mass values. In conclusion, inter-study comparisons of articular pendulum μ values should not be made without recognizing the loads used, as μ values are mass dependent. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Measurement of model coefficients of skin sympathetic vasoconstriction

    International Nuclear Information System (INIS)

    Severens, Natascha M W; Van Marken Lichtenbelt, Wouter D; Frijns, Arjan J H; Kingma, Boris R M; De Mol, Bas A J M; Van Steenhoven, Anton A

    2010-01-01

    Many researchers have already attempted to model vasoconstriction responses, commonly using the mathematical representation proposed by Stolwijk (1971 NASA Contractor Report CR-1855 (Washington, DC: NASA)). Model makers based the parameter values in this formulation either on estimations or by attributing the difference between their passive models and measurement data fully to thermoregulation. These methods are very sensitive to errors. This study aims to present a reliable method for determining physiological values in the vasoconstriction formulation. An experimental protocol was developed that enabled us to derive the local proportional amplification coefficients of the toe, leg and arm and the transient vasoconstrictor tone. Ten subjects participated in a cooling experiment. During the experiment, core temperature, skin temperature, skin perfusion, forearm blood flow and heart rate variability were measured. The contributions to the normalized amplification coefficient for vasoconstriction of the toe, leg and arm were 84%, 11% and 5%, respectively. Comparison with relative values in the literature showed that the estimated values of Stolwijk and the values mentioned by Tanabe et al (2002 Energy Build. 34 637–46) were comparable with our measured values, but the values of Gordon (1974 The response of a human temperature regulatory system model in the cold PhD Thesis University of California, Santa Barbara) and Fiala et al (2001 Int. J. Biometeorol. 45 143159) differed significantly. With the help of regression analysis a relation was formulated between the error signal of the standardized core temperature and the vasoconstrictor tone. This relation was formulated in a general applicable way, which means that it can be used for situations where vasoconstriction thresholds are shifted, like under anesthesia or during motion sickness

  10. Simultaneous interferometric measurement of linear coefficient of thermal expansion and temperature-dependent refractive index coefficient of optical materials.

    Science.gov (United States)

    Corsetti, James A; Green, William E; Ellis, Jonathan D; Schmidt, Greg R; Moore, Duncan T

    2016-10-10

    Characterizing the thermal properties of optical materials is necessary for understanding how to design an optical system for changing environmental conditions. A method is presented for simultaneously measuring both the linear coefficient of thermal expansion and the temperature-dependent refractive index coefficient of a sample interferometrically in air. Both the design and fabrication of the interferometer is presented as well as a discussion of the results of measuring both a steel and a CaF2 sample.

  11. Artificial absorption creation for more accurate tunable diode laser absorption spectroscopy measurement

    Science.gov (United States)

    Wei, Wei; Chang, Jun; Cao, Lihua; Liu, Yuanyuan; Chen, Xi; Zhu, Cunguang; Qin, Zengguang

    2017-09-01

    A novel strategy for more accurate tunable diode laser absorption spectroscopy (TDLAS) measurement is presented. This method is immune to non-absorption transmission losses, and allows dead zone removal for ultra-low concentration detection, and reference point selection at atmospheric pressure. The method adjusts laser emission and creates artificial absorption peaks according to requirements. By creating an artificial absorption peak next to the real absorption zone, calibration is not necessary. The developed method can be applied to not only wavelength modulation spectroscopy (WMS) but also direct absorption (DA). In WMS, the method does not need two harmonic signals, resulting in higher reliability, better performance, and no electro-optical gain uncertainty. At the same time, non-absorption transmission losses effect is suppressed from 70% to 0.425% with DA and from 70% to 0.225% with WMS method. When the artificial absorption peak coincides with the real one, the dead zone of measurement can be removed to give a lower detection limit, and water vapor still can be detected when concentration is lower than 0.2 ppm in our experiment. Reference point selection uncertainty with the DA method, especially when the signal-to-noise ratio is low and absorption line is broad, can also be facilitated. And the uncertainty of reference point selection is improved from 6% to 0.8% by measuring reference point amplitude. The method is demonstrated and validated by WMS and DA measurements of water vapor (1 atm, 296 K, 1368.597 nm). The measurement results obtained using the new method reveal its promise in TDLAS.

  12. Aerosol light absorption and its measurement: A review

    International Nuclear Information System (INIS)

    Moosmueller, H.; Chakrabarty, R.K.; Arnott, W.P.

    2009-01-01

    Light absorption by aerosols contributes to solar radiative forcing through absorption of solar radiation and heating of the absorbing aerosol layer. Besides the direct radiative effect, the heating can evaporate clouds and change the atmospheric dynamics. Aerosol light absorption in the atmosphere is dominated by black carbon (BC) with additional, significant contributions from the still poorly understood brown carbon and from mineral dust. Sources of these absorbing aerosols include biomass burning and other combustion processes and dust entrainment. For particles much smaller than the wavelength of incident light, absorption is proportional to the particle volume and mass. Absorption can be calculated with Mie theory for spherical particles and with more complicated numerical methods for other particle shapes. The quantitative measurement of aerosol light absorption is still a challenge. Simple, commonly used filter measurements are prone to measurement artifacts due to particle concentration and modification of particle and filter morphology upon particle deposition, optical interaction of deposited particles and filter medium, and poor angular integration of light scattered by deposited particles. In situ methods measure particle absorption with the particles in their natural suspended state and therefore are not prone to effects related to particle deposition and concentration on filters. Photoacoustic and refractive index-based measurements rely on the heating of particles during light absorption, which, for power-modulated light sources, causes an acoustic signal and modulation of the refractive index in the air surrounding the particles that can be quantified with a microphone and an interferometer, respectively. These methods may suffer from some interference due to light-induced particle evaporation. Laser-induced incandescence also monitors particle heating upon absorption, but heats absorbing particles to much higher temperatures to quantify BC mass

  13. Correction of optical absorption and scattering variations in Laser Speckle Rheology measurements.

    Science.gov (United States)

    Hajjarian, Zeinab; Nadkarni, Seemantini K

    2014-03-24

    Laser Speckle Rheology (LSR) is an optical technique to evaluate the viscoelastic properties by analyzing the temporal fluctuations of backscattered speckle patterns. Variations of optical absorption and reduced scattering coefficients further modulate speckle fluctuations, posing a critical challenge for quantitative evaluation of viscoelasticity. We compare and contrast two different approaches applicable for correcting and isolating the collective influence of absorption and scattering, to accurately measure mechanical properties. Our results indicate that the numerical approach of Monte-Carlo ray tracing (MCRT) reliably compensates for any arbitrary optical variations. When scattering dominates absorption, yet absorption is non-negligible, diffusing wave spectroscopy (DWS) formalisms perform similar to MCRT, superseding other analytical compensation approaches such as Telegrapher equation. The computational convenience of DWS greatly simplifies the extraction of viscoelastic properties from LSR measurements in a number of chemical, industrial, and biomedical applications.

  14. Pavement sound absorption measurements in the U.S.

    Science.gov (United States)

    2012-08-19

    In the U.S., the topic of pavement sound absorption in regard to tire-pavement noise has shown increased interest and research over the last several years. Four types of pavement sound absorption measurements with various applications are discussed: ...

  15. Chemical and spectral behavior of nitric acid in aqueous sulfuric acid solutions: Absorption spectrum and molar absorption coefficient of nitronium ion

    Science.gov (United States)

    Ershov, Boris G.; Panich, Nadezhda M.

    2018-01-01

    The chemical species formed from nitric acid in aqueous solutions of sulfuric acid (up to 18.0 mol L- 1) were studied by optical spectroscopy method. The concentration region of nitronium ion formation was identified and NO2+ ion absorption spectrum was measured (λmax ≤ 190 nm and ε190 = 1040 ± 50 mol- 1 L cm- 1).

  16. Water absorption lines, 931-961 nm - Selected intensities, N2-collision-broadening coefficients, self-broadening coefficients, and pressure shifts in air

    Science.gov (United States)

    Giver, L. P.; Gentry, B.; Schwemmer, G.; Wilkerson, T. D.

    1982-01-01

    Intensities were measured for 97 lines of H2O vapor between 932 and 961 nm. The lines were selected for their potential usefulness for remote laser measurements of H2O vapor in the earth's atmosphere. The spectra were obtained with several different H2O vapor abundances and N2 broadening gas pressures; the spectral resolution was 0.046/cm FWHM. Measured H2O line intensities range from 7 x 10 to the -25th to 7 x 10 to the -22nd/cm per (molecules/sq cm). H2O self-broadening coefficients were measured for 13 of these strongest lines; the mean value was 0.5/cm per atm. N2-collision-broadening coefficients were measured for 73 lines, and the average was 0.11 cm per atm HWHM. Pressure shifts in air were determined for a sample of six lines between 948 and 950 nm; these lines shift to lower frequency by an amount comparable to 0.1 of the collision-broadened widths measured in air or N2. The measured intensities of many lines of 300-000 band are much larger than expected from prior computations, in some cases by over an order of magnitude. Coriolis interactions with the stronger 201-000 band appear to be the primary cause of the enhancement of these line intensities.

  17. ANALYSIS OF UNCERTAINTY MEASUREMENT IN ATOMIC ABSORPTION SPECTROPHOTOMETER

    OpenAIRE

    NEHA S.MAHAJAN; NITIN K. MANDAVGADE; S.B. JAJU

    2012-01-01

    A spectrophotometer is a photometer that can measure intensity as a function of the light source wavelength. The important features of spectrophotometers are spectral bandwidth and linear range of absorption or reflectance measurement. Atomic absorption spectroscopy (AAS) is a very common technique for detecting chemical composition of elements in metal and its alloy. It is very reliable and simple to use. Quality of result (accuracy) depends on the uncertainty of measurement value of the tes...

  18. Guided-mode-resonance-enhanced measurement of thin-film absorption.

    Science.gov (United States)

    Wang, Yifei; Huang, Yin; Sun, Jingxuan; Pandey, Santosh; Lu, Meng

    2015-11-02

    We present a numerical and experimental study of a guided-mode-resonance (GMR) device for detecting surface-bound light-absorbing thin films. The GMR device functions as an optical resonator at the wavelength strongly absorbed by the thin film. The GMR mode produces an evanescent field that results in enhanced optical absorption by the thin film. For a 100-nm-thick lossy thin film, the GMR device enhances its absorption coefficients over 26 × compared to a conventional glass substrate. Simulations show the clear quenching effect of the GMR when the extinction coefficient is greater than 0.01. At the resonant wavelength, the reflectance of the GMR surface correlates well with the degree of optical absorption. GMR devices are fabricated on a glass substrate using a surface-relief grating and a titanium-dioxide coating. To analyze a visible absorbing dye, the reflection coefficient of dye-coated GMR devices was measured. The GMR-based method was also applied to detecting acid gases, such as hydrochloric vapor, by monitoring the change in absorption in a thin film composed of a pH indicator, bromocresol green. This technique potentially allows absorption analysis in the visible and infrared ranges using inexpensive equipment.

  19. [Ru(bpy)(3)](2+) as a reference in transient absorption spectroscopy: differential absorption coefficients for formation of the long-lived (3)MLCT excited state.

    Science.gov (United States)

    Müller, Pavel; Brettel, Klaus

    2012-04-01

    Transient absorption spectroscopy and other time-resolved methods are commonly used to study chemical reactions and biological processes induced by absorption of light. In order to scale the signal amplitude or to compare results obtained under different conditions, it is advisable to use a reference system, a standard of convenient and well-defined properties. Finding Tris(bipyridine)ruthenium(ii), [Ru(bpy)(3)](2+), a suitable candidate for a transient-absorption spectroscopy reference due to its favourable photochemical properties, we have determined accurate relative values of differential molar absorption coefficients (Δε) for light-induced formation of the metal-to-ligand charge transfer (MLCT) excited triplet state at several relevant wavelengths (wavelengths of commercially available lasers) in the UV and visible regions. We have also attempted to determine the absolute value of Δε close to the wavelength of maximum bleaching (∼450 nm) and we propose to narrow down the interval of conceivable values for Δε(450) from the broad range of published values (-0.88 × 10(4) M(-1)cm(-1) to -1.36 × 10(4) M(-1)cm(-1)) to -1.1 × 10(4) M(-1)cm(-1)± 15%. Having ourselves successfully applied [Ru(bpy)(3)](2+) as a standard in a recent time-resolved study of enzymatic DNA repair, we would like to encourage other scientists to use this convenient tool as a reference in their future spectroscopic studies on time scales from picoseconds to hundreds of nanoseconds.

  20. Infrared Light Absorption Computed Tomography Measurements for Gaseous Hydrocarbon Fuel Concentration

    Science.gov (United States)

    Kawazoe, Hiromitsu; Emi, Yasuyuki; Nakamura, Yoshiaki

    A system to measure gaseous fuel distribution was devised, which is based on infra-red light absorption by carbon-hydrogen stretch mode of vibration and the computed tomography method (IR-CT method). Since the incident light intensity from an infra-red laser fluctuated temporally, the effect was diminished by dividing the beam to two, one of which was monitored for better measurement accuracy. It was found that the error due to the laser fluctuation was within 0.8% and the feasibility of the IR-CT method was confirmed by applying the system to the measurements of the methane fuel concentration in an internal combustion engine model and a burner with diffusion flame. Furthermore, calibration to determine absorptivity was undertaken, which was used for the conversions from the measured line absorption coefficients to spatial fuel concentration in the combustion field.

  1. Water vapor spectroscopy in the 815-nm wavelength region for Differential Absorption Lidar measurements

    Science.gov (United States)

    Ponsardin, Patrick; Browell, Edward V.

    1995-01-01

    The differential absorption lidar (DIAL) technique was first applied to the remote measurement of atmospheric water vapor profiles from airborne platforms in 1981. The successful interpretation of the lidar profiles relies strongly on an accurate knowledge of specific water vapor absorption line parameters: line strength, pressure broadening coefficient, pressure-induced shift coefficient and the respective temperature-dependence factors. NASA Langley Research Center has developed and is currently testing an autonomous airborne water vapor lidar system: LASE (Lidar Atmospheric Sensing Experiment). This DIAL system uses a Nd:YAG-pumped Ti:Sapphire laser seeded by a diode laser as a lidar transmitter. The tunable diode has been selected to operate in the 813-818 nm wavelength region. This 5-nm spectral interval offers a large distribution of strengths for temperature-insensitive water vapor absorption lines. In support of the LASE project, a series of spectroscopic measurements were conducted for the 16 absorption lines that have been identified for use in the LASE measurements. Prior to this work, the experimental data for this water vapor absorption band were limited - to our knowledge - to the line strengths and to the line positions.

  2. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures.

    Science.gov (United States)

    Someswara Rao, Chinta; Viswanadha Raju, S

    2016-03-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.

  3. Characterization of Lorenz number with Seebeck coefficient measurement

    International Nuclear Information System (INIS)

    Kim, Hyun-Sik; Gibbs, Zachary M.; Tang, Yinglu; Wang, Heng; Snyder, G. Jeffrey

    2015-01-01

    In analyzing zT improvements due to lattice thermal conductivity (κ L ) reduction, electrical conductivity (σ) and total thermal conductivity (κ Total ) are often used to estimate the electronic component of the thermal conductivity (κ E ) and in turn κ L from κ L = ∼ κ Total − LσT. The Wiedemann-Franz law, κ E = LσT, where L is Lorenz number, is widely used to estimate κ E from σ measurements. It is a common practice to treat L as a universal factor with 2.44 × 10 −8 WΩK −2 (degenerate limit). However, significant deviations from the degenerate limit (approximately 40% or more for Kane bands) are known to occur for non-degenerate semiconductors where L converges to 1.5 × 10 −8 WΩK −2 for acoustic phonon scattering. The decrease in L is correlated with an increase in thermopower (absolute value of Seebeck coefficient (S)). Thus, a first order correction to the degenerate limit of L can be based on the measured thermopower, |S|, independent of temperature or doping. We propose the equation: L=1.5+exp[−(|S|)/(116) ] (where L is in 10 −8 WΩK −2 and S in μV/K) as a satisfactory approximation for L. This equation is accurate within 5% for single parabolic band/acoustic phonon scattering assumption and within 20% for PbSe, PbS, PbTe, Si 0.8 Ge 0.2 where more complexity is introduced, such as non-parabolic Kane bands, multiple bands, and/or alternate scattering mechanisms. The use of this equation for L rather than a constant value (when detailed band structure and scattering mechanism is not known) will significantly improve the estimation of lattice thermal conductivity

  4. Higher values of spectral response, absorption coefficient and external quantum efficiency of solar cell in the form of pyramids

    Science.gov (United States)

    Hamel, A.

    2017-05-01

    This paper presents a study on spectral response, absorption coefficient and external quantum efficiency of solar cell in the form of pyramid [1, 2]. We investigate to what extent and under what conditions we want to take advantage of ray incidence Seven times [3, 4]. It is found that these analyses can be used to determine the optimal surface texture which provides the best light trapping for solar cells in terms of the total internal reflection occurring in the high-index medium at incidence angles larger than the nominal critical angle [3-9]. One of the main contributions of this paper is the analysis and quantification of the influence of the opening between the heads of the two closest pyramids in textured surface for solar cells and its application on the photovoltaic parameters. In this model we show that the material can have seven successive incident ray absorptions instead of five currently, where we changed the direction of the reflected ray, by identifying and install the angle between the two neighbouring pyramids, the incidence angle, the opening between the heads of the two closest pyramids and their height. Thus, with an angle between the two neighbouring pyramid fixed at 12° and for angle of incidence fixed at 84°. For these values of the angle between the two neighbouring pyramids and incidence angle, the opening between the heads of the two closest pyramids fixed at 2.10 μm for a pyramid height of 10 μm. This leads to the largest possible increase in optical efficiency, such as spectral response, Absorption Coefficient and External Quantum Efficiency. The results are in good agreement with the available literature.

  5. Analytic calculation of the nonzero fast wave reflection coefficient from the tunneling equation with absorption

    International Nuclear Information System (INIS)

    Ng, C.S.; Swanson, D.G.

    1994-01-01

    An analytic series expression of the nonzero fast wave reflection coefficient has been found from the tunneling equation which models the wave propagation in weakly inhomogeneous media near a back-to-back resonance-cutoff pair. Explicit calculations are done for both second ion cyclotron and second electron cyclotron harmonic cases. Numerical values of this expression are compared to those calculated by solving an integral equation iteratively. They agree well with each other whenever both the series and the iteration converge. This result is based on a new method of evaluating integrals derived from the integral equation without having to solve the equation itself. This new method may have more applications and deserves further research and development

  6. H + O3 Fourier-transform infrared emission and laser absorption studies of OH(X2Pi) radical - An experimental dipole moment function and state-to-state Einstein A coefficients

    Science.gov (United States)

    Nelson, David D., Jr.; Schiffman, Aram; Nesbitt, David J.; Orlando, John J.; Burkholder, James B.

    1990-01-01

    FTIR emission/absorption spectroscopy is used to measure the relative intensities of 88 pairs of rovibrational transitions of OH(X2Pi) distributed over 16 vibrational bands. The experimental technique used to obtain the Einstein A ratios is discussed. The dipole moment function which follows from the intensity ratios along with Einstein A coefficients calculated from mu(r) is presented.

  7. Guideline for Adopting the Local Reaction Assumption for Porous Absorbers in Terms of Random Incidence Absorption Coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2011-01-01

    resistivity and the absorber thickness on the difference between the two surface reaction models are examined and discussed. For a porous absorber backed by a rigid surface, the assumption of local reaction always underestimates the random incidence absorption coefficient and the local reaction models give......Room surfaces have been extensively modeled as locally reacting in room acoustic predictions although such modeling could yield significant errors under certain conditions. Therefore, this study aims to propose a guideline for adopting the local reaction assumption by comparing predicted random...... incidence acoustical characteristics of typical building elements made of porous materials assuming extended and local reaction. For each surface reaction, five well-established wave propagation models, the Delany-Bazley, Miki, Beranek, Allard-Champoux, and Biot model, are employed. Effects of the flow...

  8. A Simple Measurement of the Sliding Friction Coefficient

    Science.gov (United States)

    Gratton, Luigi M.; Defrancesco, Silvia

    2006-01-01

    We present a simple computer-aided experiment for investigating Coulomb's law of sliding friction in a classroom. It provides a way of testing the possible dependence of the friction coefficient on various parameters, such as types of materials, normal force, apparent area of contact and sliding velocity.

  9. Measurement of mass attenuation coefficients in some Cr, Co and ...

    Indian Academy of Sciences (India)

    compounds for photon energies that lie within 1 keV above the Br K-edge. Nagel. [18] had also pointed out, while discussing the absorption edge effects in electron probe microanalysis, that the tabulated μ/ρ values can be in error by ±50% near the edge and by ±10% up to 400 eV above the edge. Jackson [19] pointed out ...

  10. Electrochemical measurements of diffusion coefficients and activity coefficients for MnCl2 in molten eutectic LiCl-KCl

    Science.gov (United States)

    Horvath, D.; Rappleye, D.; Bagri, P.; Simpson, M. F.

    2017-09-01

    An electrochemical study of manganese chloride in molten salt mixtures of eutectic LiCl-KCl was carried out using a variety of electrochemical methods in a high temperature cell including cyclic voltammetry (CV), chronopotentiometry (CP), chronoamperometry (CA), and open circuit potentiometry. Single step reduction from Mn2+ to Mn(0) was observed on both W and Mo working electrodes. Using a combination of these methods, measurements were made of activity coefficient and diffusion coefficient for MnCl2 in LiCl-KCl as a function of concentration (3.54 × 10-4 to 3.60 × 10-3 mol fraction of MnCl2) at 773K. From OCP measurements, values for activity coefficient varied from 0.014 to 0.0071. Diffusion coefficients varied with concentration and differed based on measurement method (CV, CA, or CP). Based on cyclic Mn(II) ranged from 1.1 to 2.8 × 10-5 cm2/s depending on concentration.

  11. Measurements of scattering and absorption in mammalian cell suspensions

    Science.gov (United States)

    Mourant, Judith R.; Freyer, James P.; Johnson, Tamara M.

    1996-04-01

    During the past several years a range of spectroscopies, including fluorescence and elastic- scatter spectroscopy, have been investigated for optically based detection of cancer and other tissue pathologies. Both elastic-scatter and fluorescence signals depend, in part, on scattering and absorption properties of the cells in the tissue. Therefore an understanding of the scattering and absorption properties of cells is a necessary prerequisite for understanding and developing these techniques. Cell suspensions provide a simple model with which to begin studying the absorption and scattering properties of cells. In this study we have made preliminary measurements of the scattering and absorption properties of suspensions of mouse mammary carcinoma cells (EMT6) over a broad wavelength range (380 nm to 800 nm).

  12. Light absorption coefficients by phytoplankton pigments, suspended particles and colored dissolved organic matter in the Crimea coastal water (the Black sea) in June 2016

    Science.gov (United States)

    Moiseeva, N.; Churilova, T.; Efimova, T.; Krivenko, O.; Latushkin, A.

    2017-11-01

    Variability of the bio-optical properties of the Crimean coastal waters in June 2016 has been analyzed. The type of vertical distribution chlorophyll a concentration and phytoplankton light absorption coefficients and spectra shape differed between shallow and deeper water. In the deeper water seasonal stratification divided euphotic zone into layers with different environmental conditions. In the deeper part of the euphotic zone (below the thermocline) phytoplankton absorption spectra had local maximum at 550 nm, which was likely to be associated with high abundance of cyanobacteria (Synechococcus sps.) in the phytoplankton community. The concentration of chlorophyll a specific light absorption coefficient of phytoplankton decreased with depth (especially pronounced in the blue domain of the spectrum). In the shallow water the vertical distributions of all absorption properties were relatively homogeneous due to vertical water mixing. In the shallow water non-algal particles light absorption coefficient and its contribution to total particulate absorption were higher than those in the deeper water. The non-algal particles (NAP) and colored dissolved organic matter (CDOM) light absorption spectra were well described by an exponential function with a slope averaging 0.010 nm-1 (SD = 0.001 nm-1) and 0.022 nm-1 (SD = 0.0060 nm-1), correspondingly. The CDOM absorption at 440 nm and slope coefficient varied significantly across the investigated area, which was possibly associated with the terrestrial influences. The assessment of the contribution of phytoplankton, NAP and CDOM to total light absorption showed that CDOM dominated in the absorption at 440 nm.

  13. Distinct positive temperature coefficient effect of polymer-carbon fiber composites evaluated in terms of polymer absorption on fiber surface.

    Science.gov (United States)

    Zhang, Xi; Zheng, Shaodi; Zheng, Xiaofang; Liu, Zhengying; Yang, Wei; Yang, Mingbo

    2016-03-21

    In this article, the positive temperature coefficient (PTC) effect was studied for high-density polyethylene (HDPE)/carbon fiber (CF) composites. All of the samples showed a significant PTC effect during the heating processes without a negative temperature coefficient (NTC) effect, even at a temperature much higher than the melting point of the polymer matrix. An ever-increasing PTC intensity with increasing thermal cycles was observed in our study that had never been reported in previous research. The absence of a NTC effect resulted from the increased binding force between the matrix and fillers that contributed to the very special structure of CF surface. We incorporated thermal expansion theory and quantum tunneling effects to explain PTC effect. From the SEM micrographs for the HDPE/CF composites before and after the different thermal cycles, we found that the surface of CF was covered with a layer of polymer which resulted in a change in the gap length between CF and HDPE and its distribution. We believed that the gap change induced by polymer absorption on the fiber surface had a great effect on the PTC effect.

  14. piezoelectric resonance, nonlinear-optical crystals, optical absorption, heat transfer coefficient

    Science.gov (United States)

    Zhang, Y.; Sun, J.; Rolfe, P.

    2011-06-01

    Functional near-infrared spectroscopy (fNIRS) is a sensitive technique that has the potential to detect haemodynamic changes during the performance of specific activation tasks. However, in real situations, fNIRS recordings are often corrupted by physiological phenomena, especially by cardiac contraction, breathing and blood pressure fluctuations, and these forms of interference can severely limit the utility of fNIRS. We present a novel fNIRS enhancement based on the multidistance fNIRS method with short-distance and long-distance optode pairs. With this method empirical mode decomposition (EMD) is applied to decompose the superficial haemodynamic changes, derived from the short-distance fNIRS measurements, into a series of intrinsic mode functions (IMFs). By utilizing the weighting parameters for the IMFs, we perform an estimation for global interference in the desired haemodynamic changes, derived from the long-distance fNIRS measurements. We recover the evoked brain activity by minimizing least squares between the desired haemodynamic changes and the estimated global interference. To accelerate the computation, we adopt the recursive least squares (RLS) to decrease the computation complexity due to the matrix inversion. Monte Carlo simulations based on a five-layered slab model of a human adult head was implemented to evaluate our methodology. The results demonstrate that the EMD-RLS method can effectively remove contamination from the evoked brain activity.

  15. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    Science.gov (United States)

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  16. Plasma absorption evidence via chirped pulse spectral transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Minardi, Stefano [Institute of Applied Physics, Friedrich-Schiller-University Jena, Max-Wien-Platz 1, 07743 Jena (Germany); Couairon, Arnaud; Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, F-91128 Palaiseau (France); Selva, Marco; Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2015-06-08

    This work aims at highlighting the plasma generation dynamics and absorption when a Bessel beam propagates in glass. We developed a simple diagnostics allowing us to retrieve clear indications of the formation of the plasma in the material, thanks to transmission measurements in the angular and wavelength domains. This technique featured by the use of a single chirped pulse having the role of pump and probe simultaneously leads to results showing the plasma nonlinear absorption effect on the trailing part of the pulse, thanks to the spectral-temporal correspondence in the measured signal, which is also confirmed by numerical simulations.

  17. The effect analysis of conic coefficient error based on data measured from Talysurf and simulation of Zernike coefficients

    Science.gov (United States)

    Kai, Jiang; Liu, Kai; Song, Chong; Peng, Qiu; Peng, Wang; Li, Gang

    2016-09-01

    Derivation of the conic coefficient error of practical aspheric optic surface is quite significant to aspheric machining accuracy, optical system imaging quality analysis and decomposition analysis of optical lenses. The primary mirror of R-c telescope system was tested by Taylor Hobson Talysurf. The practical surface was fitted using Zernike polynomials based on the date measured from Talysurf. Though taking the Zernike coefficients into the optical system, the effect of the aberration which was brought by optical machining to the optical system imaging quality was obtained. The analysis shows that the spherical aberration was brought into the optical system because of the figure error of the primary mirror. And the value of the spherical aberration was same to the practical alignment result. Then the conicoid aspherical degree of the primary mirror was tested by the Talysurf. The machining deviation of the conic coefficient was gotten though comparing the conicoid aspherical degree of the practical primary mirror with that of the perfect primary mirror. The practical conic coefficient was calculated by the deviation. Taking the practical conic coefficient into the R-c telescope system, the degradation of the optical system imaging quality was known. Also the spherical aberration was brought into the optical system. Experimental results show that the value of the spherical aberration analyzed by the two methods is same and consist with the practical alignment result. That is to say that the conic coefficient changed due to machining error of the conicoid aspherical degree. Because of the change the spherical aberration was attached to primary mirror. And which caused the optical system imaging quality declined. Finally, corrector was designed to balance the spherical aberration of the primary mirror. Ensure that the optical system imaging quality meet the requirement.

  18. Negative Thermal Expansion Coefficient of Graphene Measured by Raman Spectroscopy

    OpenAIRE

    Yoon, Duhee; Son, Young-Woo; Cheong, Heonsik

    2011-01-01

    The thermal expansion coefficient (TEC) of single-layer graphene is estimated with temperature-dependent Raman spectroscopy in the temperature range between 200 and 400 K. It is found to be strongly dependent on temperature but remains negative in the whole temperature range, with a room temperature value of -8.0x10^{-6} K^{-1}. The strain caused by the TEC mismatch between graphene and the substrate plays a crucial role in determining the physical properties of graphene, and hence its effect...

  19. Negative thermal expansion coefficient of graphene measured by Raman spectroscopy.

    Science.gov (United States)

    Yoon, Duhee; Son, Young-Woo; Cheong, Hyeonsik

    2011-08-10

    The thermal expansion coefficient (TEC) of single-layer graphene is estimated with temperature-dependent Raman spectroscopy in the temperature range between 200 and 400 K. It is found to be strongly dependent on temperature but remains negative in the whole temperature range with a room temperature value of (-8.0 ± 0.7) × 10(-6) K(-1). The strain caused by the TEC mismatch between graphene and the substrate plays a crucial role in determining the physical properties of graphene, and hence its effect must be accounted for in the interpretation of experimental data taken at cryogenic or elevated temperatures.

  20. High-resolution absorption coefficient and refractive index spectra of common pollutant gases at millimeter and THz wavelengths

    Science.gov (United States)

    Almoayed, Nawaf N.; Piyade, Baris C.; Afsar, Mohammed N.

    2007-09-01

    Dispersive Fourier Transform Spectroscopy (DFTS) provides us with a very precise method of measuring the absorption and refractive index spectra of common pollutant gases. This paper presents the rotational transition lines of Sulfur Dioxide and Carbon Monoxide gas as a function of varying pressure using DFTS for the very first time as a combined study. The relationship between the variation of the pressure and the change in the absorption spectrum is examined and discussed in detail. Sulfur Dioxide and Carbon Monoxide gases are highly toxic, pollutant gases that are major contributors to global pollution and can potentially be used as a chemical threat. The relationship between pressure and rotational transmission lines is discussed in detail in the frequency range of 0.3 THz - 0.9 THz. These findings are crucial in characterizing these gases as well as identifying them in a blind test.

  1. Pulsed Airborne Lidar Measurements of C02 Column Absorption

    Science.gov (United States)

    Abshire, James B.; Riris, Haris; Allan, Graham R.; Weaver, Clark J.; Mao, Jianping; Sun, Xiaoli; Hasselbrack, William E.; Rodriquez, Michael; Browell, Edward V.

    2011-01-01

    We report on airborne lidar measurements of atmospheric CO2 column density for an approach being developed as a candidate for NASA's ASCENDS mission. It uses a pulsed dual-wavelength lidar measurement based on the integrated path differential absorption (IPDA) technique. We demonstrated the approach using the CO2 measurement from aircraft in July and August 2009 over four locations. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The 2009 measurements have been analyzed in detail and the results show approx.1 ppm random errors for 8-10 km altitudes and approx.30 sec averaging times. Airborne measurements were also made in 2010 with stronger signals and initial analysis shows approx. 0.3 ppm random errors for 80 sec averaging times for measurements at altitudes> 6 km.

  2. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  3. In situ sound absorption measurement: investigations on oblique incidence

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, Andries; Klemenz, M.

    2012-01-01

    A novel method for the measurement of sound absorption has been developed. By assuming that, in a single point, the sound field consists of an incident- and a reflected plane wave, the locally incident- and reflected intensities can be determined. To this purpose, the active intensity and the sum of

  4. Radioisotope studies for quantitative measurement of manganese absorption

    International Nuclear Information System (INIS)

    Helbig, U.

    1981-01-01

    Purpose of the present study was to quantitatively determine the manganese absorption in growing rats by means of radioisotopes. First of all the following factors had to be investigated, which are significant for this determination: Measurability of stable and radioactive Mn in rat tissues; labelling of stable Mn and distribution of stable and radioactive Mn in the organism; verification of the isotope dilution method and of the comparative balance method with regard to its applicability for the determination of the true Mn absorption. We useed male and female Sprague-Dawley rats. The most important results are summarized in the following: in some separate tissues measurement of stable Mn was accompanied by difficulties. The measurement of radioactive Mn however, could be performed without any problems. 10 d after i.m. injection of 54 Mn only 17% of the administered Mn was still detectable in the organism. However, there was no uniform tissue labelling found. Therefore it is possible to an only restricted extent to draw quantitative conclusions on the content of stable Mn. A high percentage of stable and radioactive Mn was found above all in the liver. The isotope dilution method permits by feces analysis to differentiate between unabsorbed Mn coming from the food and endogenic Mn coming from the organism itself. The effective Mn absorption was also determined by means of the comparative balance method. By means of the isotope dilution method we determined the quantitative Mn-absorption with staged Mn administration and the contribution of absorption and excretion to the homeostatic regulation mechanisms of Mn. We found that absorption and excretion help the organism to keep an almost constant Mn concentration even with a differing Mn supply. (orig./MG) [de

  5. Measurement of diffusion coefficient of propylene glycol in skin tissue

    Science.gov (United States)

    Genin, Vadim D.; Bashkatov, Alexey N.; Genina, Elina A.; Tuchin, Valery V.

    2015-03-01

    Optical clearing of the rat skin under the action of propylene glycol was studied ex vivo. It was found that collimated transmittance of skin samples increased, whereas weight and thickness of the samples decreased during propylene glycol penetration in skin tissue. A mechanism of the optical clearing under the action of propylene glycol is discussed. Diffusion coefficient of propylene glycol in skin tissue ex vivo has been estimated as (1.35±0.95)×10-7 cm2/s with the taking into account of kinetics of both weight and thickness of skin samples. The presented results can be useful for enhancement of many methods of laser therapy and optical diagnostics of skin diseases and localization of subcutaneous neoplasms.

  6. Absorption of sound in air - High-frequency measurements

    Science.gov (United States)

    Bass, H. E.; Shields, F. D.

    1977-01-01

    The absorption of sound in air at frequencies from 4 to 100 kHz in 1/12 octave intervals, for temperatures from 255.4 K (0 F) to 310.9 K (100 F) in 5.5 K (10 F) intervals, and at 10% relative-humidity increments between 0% and saturation has been measured. The values of free-field absorption have been analyzed to determine the relaxation frequency of oxygen for each of the 92 combinations of temperature and relative humidity studied and the results are compared to an empirical expression. The relaxation frequencies of oxygen have been analyzed to determine the microscopic energy-transfer rates.

  7. Friction coefficient measurements of silencers on specialized duct tract

    Directory of Open Access Journals (Sweden)

    Sehnalek Stanislav

    2016-01-01

    Full Text Available This article describes test methods on air duct track in Laboratory of Environmental Engineering. It focuses on measurement of silencer parameter like is pressure loss coeffcient. Firstly, the paper describe the measurement apparatus with description of calculation method by standard ISO 7235 and energy equation. Then the paper presents three ways how to accomplish measurement because such way is not covered by procedure in standard. Then follows the evaluation of results of measurements on three types of silencer designed for HVAC applications. The article is concluded with discussion over measured data with outline for further research.

  8. Towards higher stability of resonant absorption measurements in pulsed plasmas

    International Nuclear Information System (INIS)

    Britun, Nikolay; Michiels, Matthieu; Snyders, Rony

    2015-01-01

    Possible ways to increase the reliability of time-resolved particle density measurements in pulsed gaseous discharges using resonant absorption spectroscopy are proposed. A special synchronization, called “dynamic source triggering,” between a gated detector and two pulsed discharges, one representing the discharge of interest and another being used as a reference source, is developed. An internal digital delay generator in the intensified charge coupled device camera, used at the same time as a detector, is utilized for this purpose. According to the proposed scheme, the light pulses from the reference source follow the gates of detector, passing through the discharge of interest only when necessary. This allows for the utilization of short-pulse plasmas as reference sources, which is critical for time-resolved absorption analysis of strongly emitting pulsed discharges. In addition to dynamic source triggering, the reliability of absorption measurements can be further increased using simultaneous detection of spectra relevant for absorption method, which is also demonstrated in this work. The proposed methods are illustrated by the time-resolved measurements of the metal atom density in a high-power impulse magnetron sputtering (HiPIMS) discharge, using either a hollow cathode lamp or another HiPIMS discharge as a pulsed reference source

  9. Mid-IR Absorption Cross-Section Measurements of Hydrocarbons

    KAUST Repository

    Alrefae, Majed Abdullah

    2013-05-01

    Laser diagnostics are fast-response, non-intrusive and species-specific tools perfectly applicable for studying combustion processes. Quantitative measurements of species concentration and temperature require spectroscopic data to be well-known at combustion-relevant conditions. Absorption cross-section is an important spectroscopic quantity and has direct relation to the species concentration. In this work, the absorption cross-sections of basic hydrocarbons are measured using Fourier Transform Infrared (FTIR) spectrometer, tunable Difference Frequency Generation laser and fixed wavelength helium-neon laser. The studied species are methane, methanol, acetylene, ethylene, ethane, ethanol, propylene, propane, 1-butene, n-butane, n-pentane, n-hexane, and n-heptane. The Fourier Transform Infrared (FTIR) spectrometer is used for the measurements of the absorption cross-sections and the integrated band intensities of the 13 hydrocarbons. The spectral region of the spectra is 2800 – 3400 cm-1 (2.9 – 3.6 μm) and the temperature range is 673 – 1100 K. These valuable data provide huge opportunities to select interference-free wavelengths for measuring time-histories of a specific species in a shock tube or other combustion systems. Such measurements can allow developing/improving chemical kinetics mechanisms by experimentally determining reaction rates. The Difference Frequency Generation (DFG) laser is a narrow line-width, tunable laser in the 3.35 – 3.53 μm wavelength region which contains strong absorption features for most hydrocarbons due to the fundamental C-H vibrating stretch. The absorption cross-sections of propylene are measured at seven different wavelengths using the DFG laser. The temperature range is 296 – 460 K which is reached using a Reflex Cell. The DFG laser is very attractive for kinetic studies in the shock tube because of its fast time response and the potential possibility of making species-specific measurements. The Fixed wavelength

  10. Low-frequency sound absorption measurements in air

    Science.gov (United States)

    Zuckerwar, A. J.; Meredith, R. W.

    1984-01-01

    Thirty sets of sound absorption measurements in air at a pressure of 1 atmosphere are presented at temperatures from 10 C to 50 C, relative humidities from 0 to 100 percent, and frequencies from 10 to 2500 Hz. The measurements were conducted by the method of free decay in a resonant tube having a length of 18.261 m and bore diameter of 0.152 m. Background measurements in a gas consisting of 89.5 percent N2 and 10.5 percent Ar, a mixture which has the same sound velocity as air, permitted the wall and structural losses of the tube to be separated from the constituent absorption, consisting of classical rotational and vibrational absorption, in the air samples. The data were used to evaluate the vibrational relaxation frequencies of N2 and/or O2 for each of the 30 sets of meteorological parameters. Over the full range of humidity, the measured relaxation frequencies of N2 in air lie between those specified by ANSI Standard S1.26-1978 and those measured earlier in binary N2H2O mixtures. The measured relaxation frequencies could be determined only at very low values of humidity, reveal a significant trend away from the ANSI standard, in agreement with a prior investigation.

  11. Molar absorption coefficients and stability constants of metal complexes of 4-(2-pyridylazo)resorcinol (PAR): Revisiting common chelating probe for the study of metalloproteins.

    Science.gov (United States)

    Kocyła, Anna; Pomorski, Adam; Krężel, Artur

    2015-11-01

    4-(2-Pyridylazo)resorcinol (PAR) is one of the most popular chromogenic chelator used in the determination of the concentrations of various metal ions from the d, p and f blocks and their affinities for metal ion-binding biomolecules. The most important characteristics of such a sensor are the molar absorption coefficient and the metal-ligand complex dissociation constant. However, it must be remembered that these values are dependent on the specific experimental conditions (e.g. pH, solvent components, and reactant ratios). If one uses these values to process data obtained in different conditions, the final result can be under- or overestimated. We aimed to establish the spectral properties and the stability of PAR and its complexes accurately with Zn(2+), Cd(2+), Hg(2+), Co(2+), Ni(2+), Cu(2+), Mn(2+) and Pb(2+) at a multiple pH values. The obtained results account for the presence of different species of metal-PAR complexes in the physiological pH range of 5 to 8 and have been frequently neglected in previous studies. The effective molar absorption coefficient at 492 nm for the ZnHx(PAR)2 complex at pH7.4 in buffered water solution is 71,500 M(-1) cm(-1), and the dissociation constant of the complex in these conditions is 7.08×10(-13) M(2). To confirm these values and estimate the range of the dissociation constants of zinc-binding biomolecules that can be measured using PAR, we performed several titrations of zinc finger peptides and zinc chelators. Taken together, our results provide the updated parameters that are applicable to any experiment conducted using inexpensive and commercially available PAR. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. UV/VIS SPECTROMETER DETERMINATION OF CAFFEINE IN GREEN COFFEE BEANS FROM HARARGHE, ETHIOPIA, USING BEER-LAMBERT’S LAW AND INTEGRATED ABSORPTION COEFFICIENT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    EPHREM G. DEMISSIE

    2016-07-01

    Full Text Available A total of fifteen samples of green coffee (Coffea arabica L. beans from the major producing region of Hararghe Ethiopia were studied using UV-Vis spectrometer measurement caffeine quantitative analysis from coffee beans. The number density of caffeine in green coffee beans has been reported using Beer-Lambert’s law and integrating absorption coefficient technique. Our results obtained using integrated absorption and Beer-Lambert’s law has a good agreement and we observed a maximum difference of 10.4 %. Based on their low caffeine concentrations among the samples collected were found in Jarso coffee. Coffee beans from the Harar Aboker were characterized by higher concentrations of caffeine. The determined concentration for caffeine in coffee beans (% w/w ranged 0.601 % to 0.903 %. The concentrations of the caffeine varied significantly, depending on the geographical origin of the beans. The concentrations of caffeine in coffee collected from in Hararghe region were noticeably lower than their counterpart (1.0 - 1.2 % grows in the other parts of Ethiopia.

  13. Nitrogen dioxide and kerosene-flame soot calibration of photoacoustic instruments for measurement of light absorption by aerosols

    International Nuclear Information System (INIS)

    Arnott, W. Patrick; Moosmu''ller, Hans; Walker, John W.

    2000-01-01

    A nitrogen dioxide calibration method is developed to evaluate the theoretical calibration for a photoacoustic instrument used to measure light absorption by atmospheric aerosols at a laser wavelength of 532.0 nm. This method uses high concentrations of nitrogen dioxide so that both a simple extinction and the photoacoustically obtained absorption measurement may be performed simultaneously. Since Rayleigh scattering is much less than absorption for the gas, the agreement between the extinction and absorption coefficients can be used to evaluate the theoretical calibration, so that the laser gas spectra are not needed. Photoacoustic theory is developed to account for strong absorption of the laser beam power in passage through the resonator. Findings are that the photoacoustic absorption based on heat-balance theory for the instrument compares well with absorption inferred from the extinction measurement, and that both are well within values represented by published spectra of nitrogen dioxide. Photodissociation of nitrogen dioxide limits the calibration method to wavelengths longer than 398 nm. Extinction and absorption at 532 and 1047 nm were measured for kerosene-flame soot to evaluate the calibration method, and the single scattering albedo was found to be 0.31 and 0.20 at these wavelengths, respectively

  14. Measurement of the Convective Heat-Transfer Coefficient

    Science.gov (United States)

    Conti, Rosaria; Gallitto, Aurelio Agliolo; Fiordilino, Emilio

    2014-01-01

    We propose an experiment for investigating how objects cool down toward the thermal equilibrium with their surroundings. We describe the time dependence of the temperature difference of the cooling objects and the environment with an exponential decay function. By measuring the thermal constant t, we determine the convective heat-transfer…

  15. Measurements of distribution coefficients and lipophilicity values for ...

    African Journals Online (AJOL)

    Hollow fibre supported liquid membrane (HFSLM) has been applied in the measurements of distribution constants, KD and lipophilicity (log P) values for the isomeric triterpenic acids, betulinic acid (BA) and oleanolic acid (OA) isolated from indigenous plants. The results have shown that BA had an optimum pH of 3.5 while ...

  16. Evaluation of deuterated cholesterol and deuterated sitostanol for measurement of cholesterol absorption in humans.

    Science.gov (United States)

    Lütjohann, D; Meese, C O; Crouse, J R; von Bergmann, K

    1993-06-01

    The continuous isotope feeding method of Crouse and Grundy (1978. J. Lipid Res. 19: 967-971) for measurement of dietary cholesterol absorption has been modified by using markers labeled with stable isotopes ([2,2,4,4,6-2H5]cholesterol or [25,26,26,26,27,27,27-2H4]cholesterol or [26,26,26,27,27,27-2H6] cholesterol and [5,6,22,23-2H4]sitostanol) quantified by gas-liquid chromatography-selected ion monitoring. Tracing of the isotope distribution of the authentic markers and after their intestinal passage, including the microbiological products (coprostanol and coprostanone) revealed stability of the labels. The new method was evaluated in six monkeys on two occasions by comparison with the original method using radioactively labeled cholesterol and sitosterol. The results obtained by the two different methods were in excellent agreement, and absorption ranged from 49% to 73% (mean 60%) for the stable isotope method and from 51% to 69% (mean 62%) for the radioactive method. The coefficient of variation of cholesterol absorption in animals ranged from 3.9% to 15.1% (mean 7.1%) for stable isotopes and 1.9% to 13.6% (mean 5.7%) for radioactive isotopes. In twelve subjects cholesterol absorption was measured by the new method from total fecal samples frozen immediately and compared to results obtained from small fecal aliquots (approximately 1 g) sent by ordinary mail to the laboratory. A significant correlation of cholesterol absorption between the two different sample handlings was obtained (r = 0.981, P < 0.001). In addition, measurement of cholesterol absorption twice in seven volunteers 2 weeks apart revealed identical results. Thus, the new method is extremely safe and reproducible without radioactive exposure to the subjects and labortory staff and can be used on women of child-bearing age.

  17. A new consensus measure based on Pearson correlation coefficient

    OpenAIRE

    Chiclana, Francisco; Gonzalez-Arteaga, Teresa; de Andres Calle, Rocio

    2016-01-01

    Obtaining consensual solutions is an important issue in decision making processes. It depends on several factors such as experts’ opinions, principles, knowledge, experience, etc. In the literature we can find a considerable amount of consensus measurement from different research areas (from a Social Choice perspective: Alcalde-Unzu and Vorsatz [1], Alcantud, de Andres Calle and Cascon [2] and Bosch [3], among others and from Decision Making Theory: Gonzalez-Arteaga, Alcantud and ...

  18. Measurement of effective Knudsen diffusion coefficients for powder beds used in heterogeneous uptake experiments.

    Science.gov (United States)

    Boulter, James E; Marschall, Jochen

    2006-09-07

    The effective Knudsen diffusion coefficients for characteristic oxide powder beds used in heterogeneous uptake experiments have been measured using countercurrent diffusion and transient pressure drop techniques. Room-temperature thermal-velocity-normalized effective Knudsen diffusion coefficients are found to lie in the 0.15 to 0.35 microm range for magnesium silicate, aluminum oxide, and iron oxide powder beds. Measured values are compared with theoretical estimates and are consistent with low bed tortuosities (below 3) expected for media with open porosity above 0.5. The impact of uncertainties in effective diffusion coefficients on corrections of measured uptake coefficients is discussed. The value of careful uptake measurements in both the low and high sample mass limits is reinforced, as this allows uptake corrections independent of explicitly measured or estimated diffusion coefficient values. It is suggested that correction procedures requiring tortuosity values greater than 3 are suspect.

  19. Aerosol absorption coefficient and Equivalent Black Carbon by parallel operation of AE31 and AE33 aethalometers at the Zeppelin station, Ny Ålesund, Svalbard

    Science.gov (United States)

    Eleftheriadis, Konstantinos; Kalogridis, Athina-Cerise; Vratolis, Sterios; Fiebig, Markus

    2016-04-01

    Light absorbing carbon in atmospheric aerosol plays a critical role in radiative forcing and climate change. Despite the long term measurements across the Arctic, comparing data obtained by a variety of methods across stations requires caution. A method for extracting the aerosol absorption coefficient from data obtained over the decades by filter based instrument is still under development. An IASOA Aerosol working group has been initiated to address this and other cross-site aerosol comparison opportunities. Continuous ambient measurements of EBC/light attenuation by means of a Magee Sci. AE-31 aethalometer operating at the Zeppelinfjellet station (474 m asl; 78°54'N, 11°53'E), Ny Ålesund, Svalbard, have been available since 2001 (Eleftheriadis et al, 2009), while a new aethalometer model (AE33, Drinovec et al, 2014) has been installed to operate in parallel from the same inlet since June 2015. Measurements are recorded by a Labview routine collecting all available parameters reported by the two instrument via RS232 protocol. Data are reported at 1 and 10 minute intervals as averages for EBC (μg m-3) and aerosol absorption coefficients (Mm-1) by means of routine designed to report Near Real Time NRT data at the EBAS WDCA database (ebas.nilu.no) Results for the first 6 month period are reported here in an attempt to evaluate comparative performance of the two instruments in terms of their response with respect to the variable aerosol load of light absorbing carbon during the warm and cold seasons found in the high arctic. The application of available conversion schemes for obtaining the absorption coefficient by the two instruments is found to demonstrate a marked difference in their output. During clean periods of low aerosol load (EBC < 30 ng m-3), the two instruments display a better agreement with regression slope for the 880 nm signal between the two at ~ 0.9 compared to a slope at ~ 0.6 during the period of higher absorbing carbon loads (400< EBC<30 ng m

  20. Measurement of Linear Coefficient of Thermal Expansion and Temperature-Dependent Refractive Index Using Interferometric System

    Science.gov (United States)

    Corsetti, James A.; Green, William E.; Ellis, Jonathan D.; Schmidt, Greg R.; Moore, Duncan T.

    2017-01-01

    A system combining an interferometer with an environmental chamber for measuring both coefficient of thermal expansion (CTE) and temperature-dependent refractive index (dn/dT) simultaneously is presented. The operation and measurement results of this instrument are discussed.

  1. A new method on recycling coefficient measurement using impurity pellet injection in a large helical device

    Science.gov (United States)

    Nozato, Hideaki; Morita, Shigeru; Goto, Motoshi

    2005-07-01

    Recycling coefficients of carbon, aluminum, and titanium were evaluated using a new technique combining impurity pellet injection with high-spatial resolution bremsstrahlung measurement in hydrogen and helium plasmas on the large helical device. The recycling coefficient of impurities was investigated by measuring absolute intensities with the visible bremsstrahlung array. The time evolution of the bremsstrahlung signals was modeled by an impurity transport code adjusting the diffusion coefficient, convective velocity, and recycling coefficient. As a result, a finite value of the recycling coefficient was required in the case of carbon, whereas aluminum and titanium were explained as nonrecycled particles. It was also clarified that the recycling coefficient of carbon had a larger value in hydrogen plasmas (R =0.5 -0.65 ) than in helium plasmas (R =0 -0.2 ) , suggesting the formation of hydrogen molecules.

  2. Spectroscopic absorption measurement of a low-Z plasma

    International Nuclear Information System (INIS)

    Yang Jiamin; Ding Yaonan; Yan Jun; Zheng Zhijan; Li Jiaming; Zhang Baohan; Yang Guohong; Zhang Wenhai; Wang Yaomei

    2002-01-01

    Low-Z plasmas have been produced by x-ray radiative heating of a low-Z sample on the 'Xingguang II' laser facility. High-resolution transmission spectra of the low-Z plasma (CHO) have been measured by using a flat field grating spectrometer. Absorption lines of oxygen and carbon ions in the region from 1.6 nm to 5.0 nm have been observed clearly and identified. The unresolved transition array model (UTA) has been introduced to calculate the transmission spectra of the CHO plasma. The measured transmission spectra have been compared with the calculated ones and the results of other works

  3. Transient Infrared Measurement of Laser Absorption Properties of Porous Materials

    Directory of Open Access Journals (Sweden)

    Marynowicz Andrzej

    2016-06-01

    Full Text Available The infrared thermography measurements of porous building materials have become more frequent in recent years. Many accompanying techniques for the thermal field generation have been developed, including one based on laser radiation. This work presents a simple optimization technique for estimation of the laser beam absorption for selected porous building materials, namely clinker brick and cement mortar. The transient temperature measurements were performed with the use of infrared camera during laser-induced heating-up of the samples’ surfaces. As the results, the absorbed fractions of the incident laser beam together with its shape parameter are reported.

  4. Indoor Measurement of Angle Resolved Light Absorption by Black Silicon

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Iandolo, Beniamino; Davidsen, Rasmus Schmidt

    2017-01-01

    Angle resolved optical spectroscopy of photovoltaic (PV) samples gives crucial information on PV panels under realistic working conditions. Here, we introduce measurements of angle resolved light absorption by PV cells, performed indoors using a collimated high radiance broadband light source. Our...... indoor method offers a significant simplification as compared to measurements by solar trackers. As a proof-of-concept demonstration, we show characterization of black silicon solar cells. The experimental results showed stable and reliable optical responses that makes our setup suitable for indoor......, angle resolved characterization of solar cells....

  5. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  6. Retrieval of Ocean Subsurface Particulate Backscattering Coefficient from Space-Borne CALIOP Lidar Measurement

    Science.gov (United States)

    Lu, Xiaomei; Hu, Yongxiang; Pelon, Jacques; Trepte, Chip; Liu, Katie; Rodier, Sharon; Zeng, Shan; Luckher, Patricia; Verhappen, Ron; Wilson, Jamie; hide

    2016-01-01

    A new approach has been proposed to determine ocean subsurface particulate backscattering coefficient bbp from CALIOP 30deg off-nadir lidar measurements. The new method also provides estimates of the particle volume scattering function at the 180deg scattering angle. The CALIOP based layer-integrated lidar backscatter and particulate backscattering coefficients are compared with the results obtained from MODIS ocean color measurements. The comparison analysis shows that ocean subsurface lidar backscatter and particulate backscattering coefficient bbp can be accurately obtained from CALIOP lidar measurements, thereby supporting the use of space-borne lidar measurements for ocean subsurface studies.

  7. Quantitative materials analysis of micro devices using absorption-based thickness measurements

    International Nuclear Information System (INIS)

    Sim, L M; Wog, B S; Spowage, A C

    2006-01-01

    Preliminary work in designing an X-ray inspection machine with the capability of providing quantitative thickness analysis based on absorption measurements has been demonstrated. This study attempts to use the gray levels data to investigate the nature and thickness of occluded features and materials within devices. The investigation focused on metallic materials essential to semiconductor and MEMS technologies such as tin, aluminium, copper, silver, iron and zinc. The materials were arranged to simulate different feature thicknesses and sample geometries. The X-ray parameters were varied in-order to modify the X-ray energy spectrum with the aim of optimising the measurement conditions for each sample. The capability of the method to resolve differences in thicknesses was found to be highly dependent on the material. The thickness resolution with aluminium was the poorest due to its low radiographic density. The thickness resolutions achievable for silver and tin were significantly better and of the order of 0.015 mm and 0.025 mm respectively. From the linear relationship between the X-ray attenuation and sample thickness established, the energy dependent linear attenuation coefficient for each material was determined for a series of specific energy spectra. A decrease in the linear attenuation coefficient was observed as the applied voltage and thickness of the material increased. The results provide a platform for the development of a novel absorption-based thickness measurement system that can be optimised for a range of industrial applications

  8. Measuring sound absorption properties of porous materials using a calibrated volume velocity source

    International Nuclear Information System (INIS)

    Arenas, Jorge P; Darmendrail, Luis

    2013-01-01

    Measurement of acoustic properties of sound-absorbing materials has been the source of much investigation that has produced practical measuring methods. In particular, the measurement of the normal incidence sound absorption coefficient is commonly done using a well-known configuration of a tube carrying a plane wave. The sound-absorbing coefficient is calculated from the surface impedance measured on a sample of material. Therefore, a direct measurement of the impedance requires knowing the ratio between the sound pressure and the volume velocity. However, the measurement of volume velocity is not straightforward in practice and many methods have been proposed including complex transducers, laser vibrometry, accelerometers and calibrated volume velocity sources. In this paper, a device to directly measure the acoustic impedance of a sample of sound-absorbing material is presented. The device uses an internal microphone in a small cavity sealed by a loudspeaker and a second microphone mounted in front of this source. The calibration process of the device and the limitations of the method are also discussed and measurement examples are presented. The accuracy of the device was assessed by direct comparison with the standardized method. The proposed measurement method was tested successfully with various types of commercial acoustic porous materials. (paper)

  9. Viscous slip coefficients for binary gas mixtures measured from mass flow rates through a single microtube

    OpenAIRE

    Yamaguchi, H.; Takamori, K.; Perrier, P.; Graur, I.; Matsuda, Y.; Niimi, T.

    2016-01-01

    The viscous slip coefficient for helium-argon binary gas mixture is extracted from the experimental values of the mass flow rate through a microtube. The mass flow rate is measured by the constant-volume method. The viscous slip coefficient was obtained by identifying the measured mass flow rate through a microtube with the corresponding analytical expression, which is a function of the Knudsen number. The measurements were carried out in the slip flow regime where the first-order slip bounda...

  10. Differential absorption lidar systems for tropospheric and stratospheric ozone measurements

    Science.gov (United States)

    Mcdermid, I. Stuart; Haner, David A.; Kleiman, Moshe M.; Walsh, T. Daniel; White, Mary L.

    1991-01-01

    A lidar facility has been established at the Jet Propulsion Laboratory-Table Mountain Facility located at an altitude of 2300 m in the San Gabriel Mountains in Southern California. This facility is using the technique of differential absorption lidar to measure atmospheric ozone concentration profiles. Two separate systems are needed to obtain the profile from the ground up to an altitude of 45 to 50 km. An Nd:YAG-based system is described for measurements from the ground up to 15 to 20 km altitude, and an excimer-laser-based system for measurements from 15 km to 45 to 50 km altitude. The systems were designed to make high-precision, long-term measurements to aid in the detection of changes in the atmospheric ozone abundance through participation in the Network of Detection of Stratospheric Change.

  11. Measurements of light absorption efficiency in InSb nanowires

    Directory of Open Access Journals (Sweden)

    A. Jurgilaitis

    2014-01-01

    Full Text Available We report on measurements of the light absorption efficiency of InSb nanowires. The absorbed 70 fs light pulse generates carriers, which equilibrate with the lattice via electron-phonon coupling. The increase in lattice temperature is manifested as a strain that can be measured with X-ray diffraction. The diffracted X-ray signal from the excited sample was measured using a streak camera. The amount of absorbed light was deduced by comparing X-ray diffraction measurements with simulations. It was found that 3.0(6% of the radiation incident on the sample was absorbed by the nanowires, which cover 2.5% of the sample.

  12. Absorptivity Measurements and Heat Source Modeling to Simulate Laser Cladding

    Science.gov (United States)

    Wirth, Florian; Eisenbarth, Daniel; Wegener, Konrad

    The laser cladding process gains importance, as it does not only allow the application of surface coatings, but also additive manufacturing of three-dimensional parts. In both cases, process simulation can contribute to process optimization. Heat source modeling is one of the main issues for an accurate model and simulation of the laser cladding process. While the laser beam intensity distribution is readily known, the other two main effects on the process' heat input are non-trivial. Namely the measurement of the absorptivity of the applied materials as well as the powder attenuation. Therefore, calorimetry measurements were carried out. The measurement method and the measurement results for laser cladding of Stellite 6 on structural steel S 235 and for the processing of Inconel 625 are presented both using a CO2 laser as well as a high power diode laser (HPDL). Additionally, a heat source model is deduced.

  13. Effective diffusion coefficient of radon in concrete, theory and method for field measurements

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1976-01-01

    A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author)

  14. Intercomparison of measurements of distribution coefficient. Investigation of factors affecting variability of measured values

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tomoyuki; Takebe, Shinichi; Kimura, Hideo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others

    1997-10-01

    The distribution coefficient(Kd), which is defined as partitioning of solute between a solid and liquid phases, is used for various models which describe the migration behavior of nuclides in the environment. Therefore it is a very important parameter for safety assessment of nuclear facilities. Aiming at the recommendation of standard methodologies for measurement and application of Kd, we have discussed a procedure of standardization in `WG on Parameters for Safety Assessment` of `Technical Committee on Behavior of Environmental Radioactivity` which belongs to `Research Committee on Environmental Radioactivity` organized by Japan Atomic Energy Research Institute. As a first step for recommendation of a standard methodology for measurement, intercomparisons on measurement of Kd for radionuclides ({sup 60}Co, {sup 137}Cs, {sup 85}Sr and {sup 54}Mn) were carried out by four groups to evaluate the cause of variability in measured Kds. As a result of five different experiments under various conditions, it was found that the difference of chemical property of radionuclide solution, form of vessels and method of shaking have strong influence on the measured values of Kd. (author)

  15. Effects of organometallic chelates and inulin in diets for laying hens on Mn and Fe absorption coefficients and their content in egg and tissue

    Directory of Open Access Journals (Sweden)

    Cornescu Gabriela Maria

    2015-01-01

    Full Text Available The aim of this study was to evaluate effects of organic sources of manganese (Mn and iron (Fe and inulin in diets for laying hens on absorption of these minerals and their deposition in egg and tissue. The study was conducted on 90 Lohmann Brown laying hens in the period from 46-52 weeks of age, assigned to 3 groups with 30 hens/group and 3 hens/cage. The hens from the control group (C received a diet based on corn, rice bran and soybean meal with 16% of crude protein, as well as 60 mg Fe/kg and 71.9 mg Mn/kg of diet in form of inorganic salts. The formulation of the experimental diets (E1 and E2 differed from C group diet by the replacement of inorganic Fe and Mn salts by organometallic chelates of these elements, at a level of 25% lower than in the premix for group C. As source of inulin, group E1 diet also included 0.5% of dry Jerusalem artichoke, while group E2 diet included 0.5% of a product based on chicory root extract. At the end of the experiment, 6 hens from each group were slaughtered and blood serum and liver samples were collected and assayed for concentration of Fe and Mn. In the final week of the experiment, 18 eggs/group were collected for determination of Fe and Mn concentration in egg yolk. Concentration of measured blood serum parameters (haemoglobin, haematocrit, Fe and Mn in experimental (E groups were lower than in group C, but no significant differences (P>0.05 were registered. Absorption coefficients of Mn had higher values in E groups than in group C, with significant increase (P0.05 between groups were observed for Mn and Fe concentration in egg yolk.

  16. Measurement and prediction of aromatic solute distribution coefficients for aqueous-organic solvent systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, J.R.; Luthy, R.G.

    1984-06-01

    Experimental and modeling activities were performed to assess techniques for measurement and prediction of distribution coefficients for aromatic solutes between water and immiscible organic solvents. Experiments were performed to measure distribution coefficients in both clean water and wastewater systems, and to assess treatment of a wastewater by solvent extraction. The theoretical portions of this investigation were directed towards development of techniques for prediction of solute-solvent/water distribution coefficients. Experiments were performed to assess treatment of a phenolic-laden coal conversion wastewater by solvent extraction. The results showed that solvent extraction for recovery of phenolic material offered several wastewater processing advantages. Distribution coefficients were measured in clean water and wastewater systems for aromatic solutes of varying functionality with different solvent types. It was found that distribution coefficients for these compounds in clean water systems were not statistically different from distribution coefficients determined in a complex coal conversion process wastewater. These and other aromatic solute distribution coefficient data were employed for evaluation of modeling techniques for prediction of solute-solvent/water distribution coefficients. Eight solvents were selected in order to represent various chemical classes: toluene and benzene (aromatics), hexane and heptane (alkanes), n-octanol (alcohols), n-butyl acetate (esters), diisopropyl ether (ethers), and methylisobutyl ketone (ketones). The aromatic solutes included: nonpolar compounds such as benzene, toluene and naphthalene, phenolic compounds such as phenol, cresol and catechol, nitrogenous aromatics such as aniline, pyridine and aminonaphthalene, and other aromatic solutes such as naphthol, quinolinol and halogenated compounds. 100 references, 20 figures, 34 tables.

  17. Elementary reaction rate measurements at high temperatures by tunable-laser flash-absorption

    Energy Technology Data Exchange (ETDEWEB)

    Hessler, J.P. [Argonne National Laboratory, IL (United States)

    1993-12-01

    The major objective of this program is to measure thermal rate coefficients and branching ratios of elementary reactions. To perform these measurements, the authors constructed an ultrahigh-purity shock tube to generate temperatures between 1000 and 5500 K. The tunable-laser flash-absorption technique is used to measure the rate of change of the concentration of species which absorb below 50,000 cm{sup {minus}1} e.g.: OH, CH, and CH{sub 3}. This technique is being extended into the vacuum-ultraviolet spectral region where one can measure atomic species e.g.: H, D, C, O, and N; and diatomic species e.g.: O{sub 2}, CO, and OH.

  18. In-situ measurement of electroosmotic drag coefficient in Nafion membrane for the PEMFC.

    Science.gov (United States)

    Peng, Zhe; Morin, Arnaud; Huguet, Patrice; Schott, Pascal; Pauchet, Joël

    2011-11-10

    A new method based on hydrogen pump has been developed to measure the electroosmotic drag coefficient in representative PEMFC operating conditions. It allows eliminating the back-flow of water which leads to some errors in the calculation of this coefficient with previously reported electrochemical methods. Measurements have been performed on 50 μm thick Nafion membranes both extruded and recast. Contrary to what has been described in most of previous published works, the electroosmotic drag coefficient decreases as the membrane water content increases. The same trend is observed for temperatures between 25 and 80 °C. For the same membrane water content, the electroosmotic drag coefficient increases with temperature. In the same condition, there is no difference in drag coefficient for extruded Nafion N112 and recast Nafion NRE212. These results are discussed on the basis of the two commonly accepted proton transport mechanisms, namely, Grotthus and vehicular.

  19. Extending reversed-flow chromatographic methods for the measurement of diffusion coefficients to higher temperatures.

    Science.gov (United States)

    McGivern, W Sean; Manion, Jeffrey A

    2011-11-18

    A reversed-flow gas-chromatography (RF-GC) apparatus for the measurement of binary diffusion coefficients is described and utilized to measure the binary diffusion coefficients for several systems at temperatures from (300 to 723)K. Hydrocarbons are detected using flame ionization detection, and inert species can be detected by thermal conductivity. The present apparatus has been utilized to measure diffusion coefficients at substantially higher temperatures than previous RF-GC work. Characterization of the new apparatus was accomplished by comparing measured binary diffusion coefficients of dilute argon in helium to established reference values. Further diffusion coefficient measurements for dilute helium in argon and dilute nitrogen in helium (using thermal conductivity detection) and dilute methane in helium (using flame ionization detection) were performed and found to be in excellent agreement with literature values. The measurement of these well-established diffusion coefficients has shown that specific experimental conditions are required for accurate diffusion measurements using this technique, particularly at higher temperatures. Numerical simulations of the diffusion experiments are presented to demonstrate that artifacts of the analysis procedure must be specifically identified to ensure accuracy, particularly at higher temperatures. Published by Elsevier B.V.

  20. Absorption coefficient and refractive index changes of a quantum ring in the presence of spin-orbit couplings: Temperature and Zeeman effects

    Science.gov (United States)

    Zamani, A.; Azargoshasb, T.; Niknam, E.

    2017-10-01

    Effects of applied magnetic field, temperature and dimensions on the optical absorption coefficients (AC) and refractive index (RI) changes of a GaAs quantum ring are investigated in the presence of both Rashba and Dresselhaus spin-orbit interactions (SOI). To this end, the finite difference method (FDM) is used in order to numerically calculate the energy eigenvalues and eigenstates of the system while the compact density matrix approach is hired to calculate the optical properties. It is shown that application of magnetic field, temperature as well as the geometrical size in the presence of spin-orbit interactions, alter the electronic structure and consequently influence the linear and third-order nonlinear optical absorption coefficients as well as the refractive index changes of the system. Results show an obvious blue shift in optical curves with enhancing external magnetic field and temperature while the increment of dimensions result in red shift.

  1. Interferometric measurement of lines shift in flames in connection with interpretation of lined absorption method in atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    L'vov, B.V.; Polzik, L.K.; Katskov, D.A.; Kruglikova, L.P.

    1975-01-01

    This paper is concerned with interferometric measuring of the line shift in flames in the view of interpretation of absorption lines in the atomic absorption spectroscopy. The newly measured line shifts were compared to the known data on Lorentz broadening of the same lines obtained by methods free of the systematic errors. The resonant lines of the alkaline earth elements (Sr, Ca, Ba) were investigated. To reduce self-absorption in the flame the solutions with minimum concentrations of the elements were used. The computation scheme includes the spectrometer apparatus width and line broadening due to the self-absorption. Formulae are given for computing the values studied. Good agreement was observed between the computed and experimental results. Error analysis was performed. It was concluded that any line shifts in the hydrocarbons were correctly taken into an account in the absolute computations of absorption

  2. Thermal expansion coefficient measurement from electron diffraction of amorphous films in a TEM.

    Science.gov (United States)

    Hayashida, Misa; Cui, Kai; Malac, Marek; Egerton, Ray

    2018-05-01

    We measured the linear thermal expansion coefficients of amorphous 5-30 nm thick SiN and 17 nm thick Formvar/Carbon (F/C) films using electron diffraction in a transmission electron microscope. Positive thermal expansion coefficient (TEC) was observed in SiN but negative coefficients in the F/C films. In case of amorphous carbon (aC) films, we could not measure TEC because the diffraction radii required several hours to stabilize at a fixed temperature. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  3. Measurements of low energy hydrogen ion effective sticking coefficients on titanium in the Wisconsin Levitated Octupole

    Energy Technology Data Exchange (ETDEWEB)

    Garner, H.; Post, R. S.

    1981-02-01

    The effective sticking coefficient for low energy (< 30 eV) hydrogen ions on titanium gettered aluminium walls has been measured in the Wisconsin Levitated Octupole. A value of greater than 0.75 was measured. The H/sub 2/ effective sticking coefficient for the same conditions is less than 0.01. Seventy-four percent of the wall area of the Octupole is gettered. The effects of recycling on plasma parameters is also discussed.

  4. 7 CFR 3300.10 - Measurement of the K-coefficient of an insulated body.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Measurement of the K-coefficient of an insulated body... insulated body. The K-coefficient shall be measured according to the procedures in ATP, Annex 1, Appendix 2... body shall be interpreted to mean between +19 °C (+66 °F) and 21 °C (+70 °F). (c) A report of each test...

  5. Measurement of linear attenuation coefficients of gamma rays for some salts by aqueous solution method

    International Nuclear Information System (INIS)

    Teli, M.T.; Dongarge, S.M.; Mahajan, C.S.; Malode, S.S.; Nathuram, R.

    1999-01-01

    The linear attenuation coefficients of dilute aqueous solutions of some salts with varying concentrations are measured for different gamma energies (0.36 MeV to 1.33 MeV). From these measurements, linear attenuation coefficients for pure salts are obtained by using the improved technique of Teli (1998). The comparison with theoretical values shows excellent agreement. Half value thicknesses of the salts and total atomic cross sections are also evaluated. (author)

  6. Differential Absorption Lidar (DIAL) Measurements of Landfill Methane Emissions

    Science.gov (United States)

    Innocenti, Fabrizio; Robinson, Rod; Gardiner, Tom; Finlayson, Andrew; Connor, Andy

    2017-04-01

    DIFFERENTIAL ABSORPTION LIDAR (DIAL) MEASURMENTS OF LANDFILL METHANE EMISSIONS F. INNOCENTI *, R.A. ROBINSON *, T.D. GARDINER, A. FINLAYSON *, A. CONNOR* * National Physical Laboratory (NPL), Hampton Road, Teddington, Middlesex, TW11 0LW, United Kingdom Methane is one of the most important gaseous hydrocarbon species for both industrial and environmental reasons. Understanding and quantifying methane emissions to atmosphere is an important element of climate change research. Range-resolved infrared Differential Absorption Lidar (DIAL) measurements provide the means to map and quantify a wide range of different methane sources. DIAL is a powerful technique that can be used to track and quantify plumes emitted from area emission sources such as landfill sites, waste water treatment plants and petrochemical plants. By using lidar (light detection and ranging), the DIAL technique is able to make remote range-resolved single-ended measurements of the actual distribution of target gases in the atmosphere, with no disruption to normal site operational activities. DIAL provides 3D mapping of emission concentrations and quantification of emission rates for a wide range of target gases such as methane. The NPL DIAL laser source is operated alternately at two similar wavelengths. One of these, termed the "on-resonant wavelength", is chosen to be at a wavelength which is absorbed by the target species. The other, the "off-resonant wavelength", is chosen to be at a nearby wavelength which is not absorbed significantly by the target species. The two wavelengths are chosen to be close, so that the atmospheric scattering properties are the same for both wavelengths. They are also chosen so that any differential absorption due to other atmospheric species are minimised. Any measured difference in the returned signals is therefore due to absorption by the target gas. In the typical DIAL measurement configuration the mobile DIAL facility is positioned downwind of the area being

  7. Coefficients of apparent absorption of the dietary nutrients from broiler feeds that include oil industry by-products (rapeseeds, grapes, buckthorn, flax and pumpkin meals

    Directory of Open Access Journals (Sweden)

    Tatiana Dumitra PANAITE

    2017-05-01

    Full Text Available A 42-day feeding trial was conducted on 120, day-old ROSS 308 chicks assigned to 4 (C; E1; E2; E3 groups. The broilers were housed in three-tier digestibility cages (5 broilers/cage which allowed the daily recording of the feed intake and excreta located in an experimental hall with controlled environmental conditions (27.07±2.750 C; humidity 64,80±9,57%; light regimen 23h. During the starter stage (1-10 days all chicks received a conventional compound feed (C. During the grower and finisher stages, compared to C formulation, the experimental diets different proportions, varying with the stage of development, of rapeseeds and grape meals (E1, buckthorn and flax meals (E2, pumpkin meal (lot E3. The balance study was conducted for 5 days, during weeks 4 and 6. During this period, average weights from each two cages (6 samples/group of feed consumed and excreta voided (dry matter basis were recorded and sampled for: dry matter, nitrogen, fat, fibre, ash and gross energy analysis. The chicks from E1 group had a lower (P≤0.05 coefficient of dietary nitrogen absorption than E2 chicks. The coefficients of apparent absorption of the dietary fat varied with the period of development. During the finishing stage, E3 chicks had a higher (P≤0.05 coefficient of fibre absorption than groups C, E1 and E2.

  8. Measurement of iron absorption from meals contaminated with iron

    International Nuclear Information System (INIS)

    Hallberg, L.; Bjoern-Rasmussen, E.

    1981-01-01

    A method is described to measure in vitro the extent of isotopic exchange between the native nonheme food iron and added inorganic reduction to radioiron tracer. The food is digested with pepsin and trypsin in the presence of radioiron. The exchangeability of food iron is calculated from the specific activity in the food and in an extract of bathophenantroline in isoamyl alcohol obtained after digesting this food. The precision and accuracy of the method is illustrated by two kinds of studies, those in which different amounts of contamination iron are added to a meal and those evaluating contamination iron in natural meals. The present method will make it possible to measure validly iron absorption from meals contaminated with unknown amounts of iron of unknown exchangeability with the extrinsic radioiron tracer

  9. Ultra sound absorption measurements in rock samples at low temperatures

    Science.gov (United States)

    Herminghaus, C.; Berckhemer, H.

    1974-01-01

    A new technique, comparable with the reverberation method in room acoustics, is described. It allows Q-measurements at rock samples of arbitrary shape in the frequency range of 50 to 600 kHz in vacuum (.1 mtorr) and at low temperatures (+20 to -180 C). The method was developed in particular to investigate rock samples under lunar conditions. Ultrasound absorption has been measured at volcanics, breccia, gabbros, feldspar and quartz of different grain size and texture yielding the following results: evacuation raises Q mainly through lowering the humidity in the rock. In a dry compact rock, the effect of evacuation is small. With decreasing temperature, Q generally increases. Between +20 and -30 C, Q does not change much. With further decrease of temperature in many cases distinct anomalies appear, where Q becomes frequency dependent.

  10. Nonlinear absorption coefficient and optically detected electrophonon resonance in cylindrical GaAs/AlAs quantum wires with different confined phonon models

    Science.gov (United States)

    Khoa, Doan Quoc; Phuong, Le Thi Thu; Hoi, Bui Dinh

    2017-03-01

    A quantum kinetic equation for electrons interacting with confined phonons is used to investigate the nonlinear absorption of an intense electromagnetic wave by electrons in cylindrical GaAs/AlAs quantum wires. The analytic expression for absorption coefficient is calculated for three models of confined optical phonons: the dielectric continuum (DC), hydrodynamic continuum (HC), and Huang-Zhu (HZ) models. The absorption coefficient depends on the square of the electromagnetic wave amplitude. The electrophonon resonance and optically detected electrophonon resonance (ODEPR) are observed through the absorption spectrum. The full width at half maximum (the line-width) of the ODEPR peaks is obtained by a computational method. The line-width is found to increase with increasing temperature and decrease with increasing the quantum wire radius. In particular, numerical results show that the DC and HZ models lead to a similar behaviour of electron - confined phonon interaction whereas the HC model results in a quite different one, especially at small quantum wire radius. For large quantum wire radii, above mentioned phonon models have equivalent contributions to the ODEPR line-width.

  11. Study of Material Moisture Measurement Method and Instrument by the Combination of Fast Neutron Absorption and γ Absorption

    International Nuclear Information System (INIS)

    Hou Chaoqin; Gong Yalin; Zhang Wei; Shang Qingmin; Li Yanfeng; Gou Qiangyuan; Yin Deyou

    2010-01-01

    To solve the problem of on-line sinter moisture measurement in the iron making plant, we developed material moisture measurement method and instrument by the combination of fast neutron absorption and y-absorption. It overcomes the present existed problems of other moisture meters for the sinter. Compare with microwave moisture meter, the measurement dose not affected by conductance and magnetism of material; to infrared moisture meter, the measurement result dose not influenced by colour and light-reflect performance of material surface, dose not influenced by changes of material kind; to slow neutron scatter moisture meter, the measurement dose not affected by density of material and thickness of hopper wall; to the moisture measurement meter which combined by slow neutron penetrate through and y-absorption, there are definite math model and good linear relation between the measurement values, and the measurement dose not affected by material thickness, changes of material form and component. (authors)

  12. Estimating absorption coefficients of colored dissolved organic matter (CDOM using a semi-analytical algorithm for southern Beaufort Sea waters: application to deriving concentrations of dissolved organic carbon from space

    Directory of Open Access Journals (Sweden)

    A. Matsuoka

    2013-02-01

    Full Text Available A series of papers have suggested that freshwater discharge, including a large amount of dissolved organic matter (DOM, has increased since the middle of the 20th century. In this study, a semi-analytical algorithm for estimating light absorption coefficients of the colored fraction of DOM (CDOM was developed for southern Beaufort Sea waters using remote sensing reflectance at six wavelengths in the visible spectral domain corresponding to MODIS ocean color sensor. This algorithm allows the separation of colored detrital matter (CDM into CDOM and non-algal particles (NAP through the determination of NAP absorption using an empirical relationship between NAP absorption and particle backscattering coefficients. Evaluation using independent datasets, which were not used for developing the algorithm, showed that CDOM absorption can be estimated accurately to within an uncertainty of 35% and 50% for oceanic and coastal waters, respectively. A previous paper (Matsuoka et al., 2012 showed that dissolved organic carbon (DOC concentrations were tightly correlated with CDOM absorption in our study area (r2 = 0.97. By combining the CDOM absorption algorithm together with the DOC versus CDOM relationship, it is now possible to estimate DOC concentrations in the near-surface layer of the southern Beaufort Sea using satellite ocean color data. DOC concentrations in the surface waters were estimated using MODIS ocean color data, and the estimates showed reasonable values compared to in situ measurements. We propose a routine and near real-time method for deriving DOC concentrations from space, which may open the way to an estimate of DOC budgets for Arctic coastal waters.

  13. Optical measurements of absorption changes in two-layered diffusive media

    International Nuclear Information System (INIS)

    Fabbri, Francesco; Sassaroli, Angelo; Henry, Michael E; Fantini, Sergio

    2004-01-01

    We have used Monte Carlo simulations for a two-layered diffusive medium to investigate the effect of a superficial layer on the measurement of absorption variations from optical diffuse reflectance data processed by using: (a) a multidistance, frequency-domain method based on diffusion theory for a semi-infinite homogeneous medium; (b) a differential-pathlength-factor method based on a modified Lambert-Beer law for a homogeneous medium and (c) a two-distance, partial-pathlength method based on a modified Lambert-Beer law for a two-layered medium. Methods (a) and (b) lead to a single value for the absorption variation, whereas method (c) yields absorption variations for each layer. In the simulations, the optical coefficients of the medium were representative of those of biological tissue in the near-infrared. The thickness of the first layer was in the range 0.3-1.4 cm, and the source-detector distances were in the range 1-5 cm, which is typical of near-infrared diffuse reflectance measurements in tissue. The simulations have shown that (1) method (a) is mostly sensitive to absorption changes in the underlying layer, provided that the thickness of the superficial layer is ∼0.6 cm or less; (2) method (b) is significantly affected by absorption changes in the superficial layer and (3) method (c) yields the absorption changes for both layers with a relatively good accuracy of ∼4% for the superficial layer and ∼10% for the underlying layer (provided that the absorption changes are less than 20-30% of the baseline value). We have applied all three methods of data analysis to near-infrared data collected on the forehead of a human subject during electroconvulsive therapy. Our results suggest that the multidistance method (a) and the two-distance partial-pathlength method (c) may better decouple the contributions to the optical signals that originate in deeper tissue (brain) from those that originate in more superficial tissue layers

  14. Procedures and apparatus for measuring diffusion and distribution coefficients in compacted clays

    International Nuclear Information System (INIS)

    Hume, H.B.

    1993-12-01

    Diffusion and distribution coefficients are needed to assess the migration of radionuclides through the compacted clay-based buffer and backfill materials proposed for use in a nuclear fuel waste disposal vault. This report describes the techniques used to measure these coefficients. Both steady-state and transient diffusion experiments are discussed. The procedures used to prepare the clay plug, assemble the cell, conduct the experiment and calculate the results are described. In addition, methods for obtaining distribution coefficients for radionuclides on both loose and compacted clays are discussed. (author). 18 refs., 3 tabs., 16 figs

  15. Rate Coefficient Measurements of the Reaction CH3 + O2 = CH3O + O

    Science.gov (United States)

    Hwang, S. M.; Ryu, Si-Ok; DeWitt, K. J.; Rabinowitz, M. J.

    1999-01-01

    Rate coefficients for the reaction CH3 + O2 = CH3O + O were measured behind reflected shock waves in a series of lean CH4-O2-Ar mixtures using hydroxyl and methyl radical diagnostics. The rate coefficients are well represented by an Arrhenius expression given as k = (1.60(sup +0.67, sub -0.47 ) x 10(exp 13) e(-15813 +/- 587 K/T)/cubic cm.mol.s. This expression, which is valid in the temperature range 1575-1822 K, supports the downward trend in the rate coefficients that has been reported in recent determinations. All measurements to date, including the present study, have been to some extent affected by secondary reactions. The complications due to secondary reactions, choice of thermochemical data, and shock-boundary layer interactions that affect the determination of the rate coefficients are examined.

  16. Rate Coefficient Measurements of the Reaction CH3+O2+CH3O+O

    Science.gov (United States)

    Hwang, S. M.; Ryu, Si-Ok; DeWitt, K. J.; Rabinowitz, M. J.

    1999-01-01

    Rate coefficients for the reaction CH3 + O2 = CH3O + O were measured behind reflected shock waves in a series of lean CH4-O2-Ar mixtures using hydroxyl and methyl radical diagnostics. The rate coefficients are well represented by an Arrhenius expression given as k = (1.60(sup +0.67, -0.47)) X 10(exp 13) exp(- 15813 +/- 587 K/T)cc/mol s. This expression, which is valid in the temperature range 1575-1822 K, supports the downward trend in the rate coefficients that has been reported in recent determinations. All measurements to date, including the present study, have been to some extent affected by secondary reactions. The complications due to secondary reactions, choice of thermochemical data, and shock-boundary layer interactions that affect the determination of the rate coefficients are examined.

  17. MEASUREMENTS OF ABSORPTION, EMISSIVITY REDUCTION, AND LOCAL SUPPRESSION OF SOLAR ACOUSTIC WAVES IN SUNSPOTS

    International Nuclear Information System (INIS)

    Chou, D.-Y.; Liang, Z.-C.; Yang, M.-H.; Zhao Hui; Sun, M.-T.

    2009-01-01

    The power of solar acoustic waves in magnetic regions is lower relative to the quiet Sun. Absorption, emissivity reduction, and local suppression of acoustic waves contribute to the observed power reduction in magnetic regions. We propose a model for the energy budget of acoustic waves propagating through a sunspot in terms of the coefficients of absorption, emissivity reduction, and local suppression of the sunspot. Using the property that the waves emitted along the wave path between two points have no correlation with the signal at the starting point, we can separate the effects of these three mechanisms. Applying this method to helioseismic data filtered with direction and phase-velocity filters, we measure the fraction of the contribution of each mechanism to the power deficit in the umbra of the leading sunspot of NOAA 9057. The contribution from absorption is 23.3 ± 1.3%, emissivity reduction 8.2 ± 1.4%, and local suppression 68.5 ± 1.5%, for a wave packet corresponding to a phase velocity of 6.98 x 10 -5 rad s -1 .

  18. STUDY ON EUROPEAN FUNDS ABSORPTION IN ROMANIA FOR MEASURE 313

    Directory of Open Access Journals (Sweden)

    Florentina D. MATEI

    2014-06-01

    Full Text Available In this paper we wish to highlight the main causes of regional disparities in Romania in terms of absorption of European funds through Measure 313: Encouragement of tourism activities. The post-accession of Romania shows a major deficiency in attracting funds from the European Union, this situation is generated, in particular, by the lack of a coherent long-term vision of the authorities, insufficient resources for co-financing projects, low administrative capacity at central and local level, lack of inter-institutional coordination, public-private partnerships failures and insufficient skilled human resources . We will analyze the number of projects approved and implemented in each region of Romania (2007-2013 to establish the real possibilities of expansion of rural tourism.

  19. Absorption dynamics of organic chemical transport across trout gills as related to octanol-water partition coefficient

    International Nuclear Information System (INIS)

    McKim, J.; Schmieder, P.; Veith, G.

    1985-01-01

    An in vivo fish preparation was used that allowed a direct measure of the transport rates of 14 different organic chemicals across the gills of rainbow trout (Salmo gairdneri). The chemicals, all C14 labeled, were selected from five classes, encompassing a range of octanol-water partition coefficient (log P) values, from 0.23 (ethyl formate) to 7.5 (mirex). The uptake efficiency (extraction efficiency) of each chemical was determined by monitoring the inspired and expired water of trout exposed to each chemical over an exposure period of 1 to 6 hr. The mean gill extraction efficiency for all chemicals tested varied from a low of 7% to a high of 60%, extracted in a single pall of the chemical across the gills. The extraction efficiency of chemicals with log P or 1 or less were low and showed no relationship to log P. These low extraction efficiencies seen at log P of 1 and below with molecular weights below 100 were indicative of aqueous pore transport. The mean extraction efficiency for chemicals with log P values of 1 to 3 seemed to vary directly with log P, to a maximum of slightly greater than 60%, suggesting that uptake was controlled by the lipid membrane. The mean extraction efficiency for chemicals with log P of 3 to 6 was independent of log P and remained at 60%, which suggested that gill uptake was controlled by aqueous diffusion rates rather than gill membrane permeability. The mean extraction efficiency with mirex (log P . 7.5) decreased to 20%

  20. Mass attenuation and mass energy absorption coefficients for 10 keV to 10 MeV photons; Coefficients d'attenuation massique et d'absorption massique en energie pour les photons de 10 keV a 10 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Joffre, H.; Pages, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    In this report are given the elements allowing the definition of the values of mass attenuation coefficients and mass energy absorption coefficients for some elements and mixtures, necessary for the study of tissue equivalent materials, for photons in the energy range 10 keV to 10 MeV. After a short reminding of the definitions of the two coefficients, follows, in table form, a compilation of these coefficients, as a function of energy, for simple elements, for certain mineral compounds, organic compounds, gases and particularly of soft tissues. (author) [French] Dans ce rapport, sont donnes les elements permettant de determiner les valeurs des coefficients d'attenuation massique et d'absorption massique en energie pour certains elements et melanges necessaires a l'etude des materiaux equivalents aux tissus pour les photons dans le domaine d'energie allant de 10 keV a 10 MeV. Apres un bref rappel des definitions des deux coefficients, suit, sous forme de tableaux, un recueil de ces coefficients, en fonction de l'energie, pour les elements simples, certains composes mineraux, composes organiques, gaz, et, particulierement, pour les tissus mous. (auteur)

  1. Accurate on-chip measurement of the Seebeck coefficient of high mobility small molecule organic semiconductors

    Directory of Open Access Journals (Sweden)

    C. N. Warwick

    2015-09-01

    Full Text Available We present measurements of the Seebeck coefficient in two high mobility organic small molecules, 2,7-dioctyl[1]benzothieno[3,2-b][1]benzothiophene (C8-BTBT and 2,9-didecyl-dinaphtho[2,3-b:2′,3′-f]thieno[3,2-b]thiophene (C10-DNTT. The measurements are performed in a field effect transistor structure with high field effect mobilities of approximately 3 cm2/V s. This allows us to observe both the charge concentration and temperature dependence of the Seebeck coefficient. We find a strong logarithmic dependence upon charge concentration and a temperature dependence within the measurement uncertainty. Despite performing the measurements on highly polycrystalline evaporated films, we see an agreement in the Seebeck coefficient with modelled values from Shi et al. [Chem. Mater. 26, 2669 (2014] at high charge concentrations. We attribute deviations from the model at lower charge concentrations to charge trapping.

  2. Ultrasonic measurements of the reflection coefficient at a water/polyurethane foam interface.

    Science.gov (United States)

    Sagers, Jason D; Haberman, Michael R; Wilson, Preston S

    2013-09-01

    Measured ultrasonic reflection coefficients as a function of normal incidence angle are reported for several samples of polyurethane foam submerged in a water bath. Three reflection coefficient models are employed as needed in this analysis to approximate the measured data: (1) an infinite plane wave impinging on an elastic halfspace, (2) an infinite plane wave impinging on a single fluid layer overlying a fluid halfspace, and (3) a finite acoustic beam impinging on an elastic halfspace. The compressional wave speed in each sample is calculated by minimizing the sum of squared error (SSE) between the measured and modeled data.

  3. Measurement of the friction coefficient between UO2 and cladding tube

    International Nuclear Information System (INIS)

    Tachibana, Toshimichi; Narita, Daisuke; Kaneko, Hiromitsu; Honda, Yutaka

    1978-01-01

    Most of fuel rods used for light water reactors or fast reactors consist of the cladding tubes filled with UO 2 -PuO 2 pellets. The measurement was made on the coefficient of static friction and the coefficient of dynamic friction in helium under high contact load on UO 2 /Zry-2 and UO 2 /SUS 316 combined samples at the temperature ranging from room temperature to 400 deg. C and from room temperature to 600 deg. C, respectively. The coefficient of static friction for Zry-2 tube and UO 2 pellets was 0.32 +- 0.08 at room temperature and 0.47 +- 0.07 at 400 deg. C, and increased with temperature rise in this temperature range. The coefficient of static friction between 316 stainless steel tube and UO 2 pellets was 0.29 +- 0.04 at room temperature and 1.2 +- 0.2 at 600 deg. C, and increased with temperature rise in this temperature range. The coefficient of dynamic friction for both UO 2 /Zry-2 and UO 2 /SUS 316 combinations seems to be equal to or about 10% excess of the coefficient of static friction. The coefficient of static friction for UO 2 /SUS 316 combination decreased with the increasing number of repetition, when repeating slip several times on the same contact surfaces. (Kobatake, H.)

  4. DCCO and SCCO: measurements of diffusion coefficients and of thermodiffusion in microgravity; DCCO et SCCO: mesures de coefficients de diffusion et de thermodiffusion en microgravite

    Energy Technology Data Exchange (ETDEWEB)

    Legros, J.C.; Van Vaerenbergh, S.; Dubois, F.; Decroly, Y. [Universite Libre de Bruxelles (Belgium); Montel, F. [ELF-Aquitaine Production, 64 - Pau (France); Goodman, S. [C-CORE, New Foundland, (Canada); Bekaert, G. [SABCA, Bruxelles (Belgium); Van Ransbeek, E. [IASB-BIRA, Bruxelles (Belgium)

    1996-12-31

    Measurements of diffusion coefficients of ternary systems and of thermodiffusion coefficients of multicomponent systems, including crude oils, have been undertaken by MRC and Elf-Aquitaine. The experiments DCCO and SCCO (respectively Diffusion and Soret Coefficients of Crude Oils) will be performed in 1997 and 1998 in GAS containers on the Space Shuttle. The 9 systems of DCCO are analyzed by Mach-Zehnder bicolor interferometry. The samples of the 18 systems of SCCO, among which three at 300 bars and at a mean temperature of 60 deg. C, will be analyzed after recovery on ground by a chromatographic technique. Such measurements performed in microgravity, like the measurements of Soret coefficients of binary solutions performed in the microgravity SCM experiments, are necessary reference measurements. (authors) 12 refs.

  5. Precise measurement of the transverse piezoelectric coefficient for thin films on anisotropic substrate

    International Nuclear Information System (INIS)

    Chun, Doo-Man; Sato, Masashi; Kanno, Isaku

    2013-01-01

    In this study, we propose a reliable measurement method for the effective transverse piezoelectric coefficient for thin films especially on anisotropic substrate. This coefficient for piezoelectric Pb(Zr, Ti)O 3 (PZT) thin films was calculated by measuring the electric field-induced tip displacement of unimorph cantilevers composed of PZT thin films and Si substrates. We evaluated the reliability of the proposed measurement method by comparing it with numerical analysis and confirmed that the relative error of the piezoelectric coefficient (e 31,f ) was less than 1%. We prepared 16 different unimorph cantilevers composed of identical PZT films on different Si beam geometries that had various substrate thicknesses and cantilever widths. Although the effective transverse piezoelectric coefficient e 31,f of PZT thin films ranged from −6.5 to −14 C/m 2 as a function of the applied voltage, the difference among the 16 samples with an applied voltage of 25 V was within 10%. These results demonstrate that the proposed measurement method has sufficient reliability and can be used to evaluate the effective transverse piezoelectric coefficient e 31,f of thin films.

  6. Measurement of capacity coefficient of inclined liquid phase catalytic exchange column for tritiated water processing

    International Nuclear Information System (INIS)

    Yamai, Hideki; Konishi, Satoshi; Yamanishi, Toshihiko; Okuno, Kenji

    1994-01-01

    Liquid phase catalytic exchange (LPCE) is effective method for enrichment and removal of tritium from tritiated water. Capacity coefficients of operating LPCE column that are essential to evaluate column performance were measured. Experiments were performed with short catalyst packed columns and effect of inclination was studied. Method for evaluation of capacity coefficients was established from measurement of isotope concentration of liquid, vapor, gas phases at the two ends of the column. The capacity coefficients were measured under various superficial gas velocities. Feasibility study of helical columns with roughened inner surface was performed with short inclined columns. The column performance was not strongly affected by the inclination. The result indicates technological feasibility of helical LPCE column, that is expected to have operation stability and reduced height

  7. Improved approach to measure the direct flexoelectric coefficient of bulk polyvinylidene fluoride

    Science.gov (United States)

    Lu, Jianfeng; Lv, Jiangyan; Liang, Xu; Xu, Minglong; Shen, Shengping

    2016-03-01

    We experimentally studied the built-in polarization induced effective piezoelectric constant and direct flexoelectric coefficient in α-phase bulk polyvinylidene fluoride (PVDF). This phenomenon was detected and discussed based on the compression of a truncated cone. An improved mechanical formulation of flexoelectricity was presented and discussed in this study, and the experiment was carried out based on the charge measurement. From the experiment study, a flexoelectric coupling coefficient 202.3 V was calculated from the flexoelectric coefficient μ11=1.6 ×10-8C /m for bulk polyvinylidene fluoride. We measured the flexoelectric response of bulk PVDF with consideration of the residual piezoelectric contributions and geometry-dependent calibration, which affect the flexoelectric measurement.

  8. Measuring Food Intake and Nutrient Absorption in Caenorhabditis elegans

    Science.gov (United States)

    Gomez-Amaro, Rafael L.; Valentine, Elizabeth R.; Carretero, Maria; LeBoeuf, Sarah E.; Rangaraju, Sunitha; Broaddus, Caroline D.; Solis, Gregory M.; Williamson, James R.; Petrascheck, Michael

    2015-01-01

    Caenorhabditis elegans has emerged as a powerful model to study the genetics of feeding, food-related behaviors, and metabolism. Despite the many advantages of C. elegans as a model organism, direct measurement of its bacterial food intake remains challenging. Here, we describe two complementary methods that measure the food intake of C. elegans. The first method is a microtiter plate-based bacterial clearing assay that measures food intake by quantifying the change in the optical density of bacteria over time. The second method, termed pulse feeding, measures the absorption of food by tracking de novo protein synthesis using a novel metabolic pulse-labeling strategy. Using the bacterial clearance assay, we compare the bacterial food intake of various C. elegans strains and show that long-lived eat mutants eat substantially more than previous estimates. To demonstrate the applicability of the pulse-feeding assay, we compare the assimilation of food for two C. elegans strains in response to serotonin. We show that serotonin-increased feeding leads to increased protein synthesis in a SER-7-dependent manner, including proteins known to promote aging. Protein content in the food has recently emerged as critical factor in determining how food composition affects aging and health. The pulse-feeding assay, by measuring de novo protein synthesis, represents an ideal method to unequivocally establish how the composition of food dictates protein synthesis. In combination, these two assays provide new and powerful tools for C. elegans research to investigate feeding and how food intake affects the proteome and thus the physiology and health of an organism. PMID:25903497

  9. [Impact of Light Polarization on the Measurement of Water Particulate Backscattering Coefficient].

    Science.gov (United States)

    Liu, Jia; Gong, Fang; He, Xian-qiang; Zhu, Qian-kun; Huang, Hai-qing

    2016-01-01

    Particulate backscattering coefficient is a main inherent optical properties (IOPs) of water, which is also a determining factor of ocean color and a basic parameter for inversion of satellite ocean color remote sensing. In-situ measurement with optical instruments is currently the main method for obtaining the particulate backscattering coefficient of water. Due to reflection and refraction by the mirrors in the instrument optical path, the emergent light source from the instrument may be partly polarized, thus to impact the measurement accuracy of water backscattering coefficient. At present, the light polarization of measuring instruments and its impact on the measurement accuracy of particulate backscattering coefficient are still poorly known. For this reason, taking a widely used backscattering coefficient measuring instrument HydroScat6 (HS-6) as an example in this paper, the polarization characteristic of the emergent light from the instrument was systematically measured, and further experimental study on the impact of the light polarization on the measurement accuracy of the particulate backscattering coefficient of water was carried out. The results show that the degree of polarization(DOP) of the central wavelength of emergent light ranges from 20% to 30% for all of the six channels of the HS-6, except the 590 nm channel from which the DOP of the emergent light is slightly low (-15%). Therefore, the emergent light from the HS-6 has significant polarization. Light polarization has non-neglectable impact on the measurement of particulate backscattering coefficient, and the impact degree varies with the wave band, linear polarization angle and suspended particulate matter (SPM) concentration. At different SPM concentrations, the mean difference caused by light polarization can reach 15.49%, 11.27%, 12.79%, 14.43%, 13.76%, and 12.46% in six bands, 420, 442, 470, 510, 590, and 670 nm, respectively. Consequently, the impact of light polarization on the

  10. Measurements of Narrow Mg II Associated Absorption Doublets with ...

    Indian Academy of Sciences (India)

    1994; de Kool & Begelman 1995; Murray & Chiang. 1997; Proga et al. 2000; Everett 2005) ... One of the most popular methods to identify the intrinsic absorption lines is the time variations of absorption ... The corrections of galactic extinction are done with the reddening map of Schlegel et al. (1998). For each spectra, we fit a ...

  11. Design And Construction of an Impedance Tube for Measuring Sound Absorptivity and Transmissibility of Materials Using Transfer Function Method

    Science.gov (United States)

    Gowda, Haarish Kapaninaikappa

    Noise is defined as unwanted sound, when perceived in excess can cause many harmful effects such as annoyance, interference with speech, and hearing loss, hence there is a need to control noise in practical situations. Noise can be controlled actively and/or passively, here we discuss the passive noise control techniques. Passive noise control involves using energy dissipating or reflecting materials such as absorbers or barriers respectively. Damping and isolating materials are also used in eliminating structure-borne noise. These materials exhibit properties such as reflection, absorption and transmission loss when incidence is by a sound source. Thus, there is a need to characterize the acoustical properties of these materials for practical use. The theoretical background of the random incident sound absorption with reverberation room and normal incident sound absorption using impedance tube are well documented. The Transfer Matrix method for measuring transmission loss and absorption coefficient using impedance tube is very attractive since it is rather inexpensive and fast. In this research, a low-cost Impedance Tube is constructed using transfer function method to measure both absorption and transmissibility of materials. Equipment and measurement instruments available in the laboratory were used in the construction of the tube, adhering to cost-effectiveness. Care has been taken for precise construction of tube to ensure better measurement results. Further various samples varying from hard non-porous to soft porous materials were tested for absorption and sound transmission loss. Absorption values were also compared with reverberation room method with the available samples further ensuring the reliability of the newly constructed tube for future measurements.

  12. A Multi-Band Analytical Algorithm for Deriving Absorption and Backscattering Coefficients from Remote-Sensing Reflectance of Optically Deep Waters

    Science.gov (United States)

    Lee, Zhong-Ping; Carder, Kendall L.

    2001-01-01

    A multi-band analytical (MBA) algorithm is developed to retrieve absorption and backscattering coefficients for optically deep waters, which can be applied to data from past and current satellite sensors, as well as data from hyperspectral sensors. This MBA algorithm applies a remote-sensing reflectance model derived from the Radiative Transfer Equation, and values of absorption and backscattering coefficients are analytically calculated from values of remote-sensing reflectance. There are only limited empirical relationships involved in the algorithm, which implies that this MBA algorithm could be applied to a wide dynamic range of waters. Applying the algorithm to a simulated non-"Case 1" data set, which has no relation to the development of the algorithm, the percentage error for the total absorption coefficient at 440 nm a (sub 440) is approximately 12% for a range of 0.012 - 2.1 per meter (approximately 6% for a (sub 440) less than approximately 0.3 per meter), while a traditional band-ratio approach returns a percentage error of approximately 30%. Applying it to a field data set ranging from 0.025 to 2.0 per meter, the result for a (sub 440) is very close to that using a full spectrum optimization technique (9.6% difference). Compared to the optimization approach, the MBA algorithm cuts the computation time dramatically with only a small sacrifice in accuracy, making it suitable for processing large data sets such as satellite images. Significant improvements over empirical algorithms have also been achieved in retrieving the optical properties of optically deep waters.

  13. IOP from reflectance measurements to obtain the Kd coefficient: application to the Gabon and Congo coastal waters

    Science.gov (United States)

    Schmeltz, M.; Froidefond, J.-M.; Jourdain, F.; Martiny, N.

    2009-08-01

    During the "Optic-Congo" oceanographic survey which took place in 2005 on board the "Beautemp-Beaupré" SHOM vessel, different optical measurements of the surface water were acquired using a TRIOS radiance sensor fixed onboard a mini-catamaran. Hydrological measurements (CTD, fluorescence, attenuation, scattering) and water samples were simultaneously collected in order to measure SPM, Chlorophyll-a and CDOM concentrations. Four types of surface water colours (blue, green-yellow, dark and brown) were identified. The main characteristics of these waters were the very low Chlorophyll-a concentrations for this period of the year (March), and the very high CDOM concentrations along the Congo coast, and particularly in the turbid plume of the Congo River. The attenuation and scattering measurements highlighted the predominance of organic matter at the water surface. These observations were documented using a beam electron microscope and by microanalysis. This data set was used to classify the water bodies along the Gabon and Congo coasts. We propose here to use the remote sensing reflectance (Rrs) measurements to invert the IOP (absorption (a) and backscattering (bb)) using the WASI numerical bio-optical model. The model is iterative: the Rrs WASI simulations are computed given initial values of ocean constituents' concentrations and iteratively adjusted to the Rrs in-situ measurements. The IOP computations are satisfying when the correlations between simulated and measured Rrs are optimized. Then, the attenuation coefficients (Kd) are computed from the IOP coefficients. These results are compared with measurements of Ku carried out during the survey.

  14. Measurements of recombination coefficient of hydrogen atoms on plasma deposited thin films

    International Nuclear Information System (INIS)

    Drenik, A.; Vesel, A.; Mozetic, M.

    2006-01-01

    We have performed experiments in plasma afterglow in order to determine the recombination coefficients of plasma deposited thin films of tungsten and graphite. Plasma deposited films rather than bulk material were used in order to more closely emulate surface structure of plasma-facing material deposits in fusion reactors. We have also determined the recombination coefficient of 85250 borosilicate glass and Teflon. Plasma was created by means of a radio frequency generator in a mixture of argon and hydrogen at the pressures between 60 Pa and 280 Pa. The degree of dissociation of hydrogen molecules was found to be between 0.1 and 1. The H-atom density was measured by Fiber Optic Catalytic Probe. The recombination coefficient was determined by measuring the axial profile of the H-atom density and using Smith's side arm diffusion model. (author)

  15. Application of double modulation for measurement of the thermal expansion coefficient of liquid metals

    International Nuclear Information System (INIS)

    Blagonravov, L A; Karchevskiy, O O; Ivannikov, P V; Soboleva, A V

    2008-01-01

    The first results of the thermal expansion coefficient measurement obtained for liquid conductors using a new modulation method are presented. The method is based on a superposition of two periodical influences on a liquid metal. The thermal expansion coefficient α P is determined by means of measuring the amplitudes of oscillations of electric current power w ∼ and pressure p ∼ . In the present work the K-Na alloy of the eutectic composition was used as a sample. Distinction of the experimental data obtained by authors from the literature data is 30 to 40%. Such a difference is in the range of error of determination of α P from the density data of K-Na alloy. The method allows direct determination of the thermal expansion coefficient of liquid conductors in absolute units

  16. Measurements of uptake coefficients for heterogeneous loss of HO2 onto submicron inorganic salt aerosols.

    Science.gov (United States)

    George, I J; Matthews, P S J; Whalley, L K; Brooks, B; Goddard, A; Baeza-Romero, M T; Heard, D E

    2013-08-21

    Laboratory studies were conducted to investigate the kinetics of HO2 radical uptake onto submicron inorganic salt aerosols. HO2 reactive uptake coefficients were measured at room temperature using an aerosol flow tube and the Fluorescence Assay by Gas Expansion (FAGE) technique that allowed for measurements to be conducted under atmospherically relevant HO2 concentrations ([HO2] = 10(8) to 10(9) molecule cm(-3)). The uptake coefficient for HO2 uptake onto dry inorganic salt aerosols was consistently below the detection limit (γ(HO2) atmospheric models (γ(HO2) = 0.1-1.0). Evidence is presented showing that the HO2 uptake coefficients onto aqueous salt aerosol particles are dependent both on the exposure time to the aerosol and on the HO2 concentration used.

  17. Rate Coefficient Measurements and Theoretical Analysis of the OH + ( E) CF3CH=CHCF3 Reaction.

    Science.gov (United States)

    Baasandorj, Munkhbayar; Marshall, Paul; Waterland, Robert L; Ravishankara, Akkihebbal R; Burkholder, James B

    2018-04-25

    Rate coefficients, k, for the gas-phase reaction of the OH radical with (E) CF3CH=CHCF3 ((E)-1,1,14,4,4-hexafluoro-2-butene, HFO-1336mzz(E)) were measured over a range of temperature (211-374 K) and bath gas pressure (20-300 Torr; He, N2) using a pulsed laser photolysis-laser induced fluorescence (PLP-LIF) technique. k1(T) was independent of pressure over this range of conditions with k1(296 K) = (1.31 ± 0.15) × 10 13 cm3 molecule 1 s 1 and k1(T) = (6.94 ± 0.80) × 10 13 exp[ (496 ± 10)/T] cm3 molecule 1 s 1, where the uncertainties are 2 and the pre-exponential term includes estimated systematic error. Rate coefficients for the OD reaction were also determined over a range of temperature (262-374 K) at 100 Torr (He). The OD rate coefficients were ~15% greater than the OH values and showed similar temperature dependent behavior with k2(T) = (7.52 ± 0.44) × 10 13 exp[ (476 ± 20)/T] and k2(296 K) = (1.53 ± 0.15) × 10 13 cm3 molecule 1 s 1. The rate coefficients for reaction 1 were also measured using a relative rate technique between 296 and 375 K with k1(296 K) measured to be (1.22 ± 0.1) × 10 13 cm3 molecule 1 s 1 in agreement with the PLP-LIF results. In addition, the 296 K rate coefficient for the O3 + (E) CF3CH=CHCF3 reaction was determined to be reaction and the significant decrease in OH reactivity compared to the (Z) CF3CH=CHCF3 stereoisomer reaction. The estimated atmospheric lifetime of (E) CF3CH=CHCF3, due to loss by reaction with OH, is estimated to be ~90 days, while the actual lifetime will depend on the location and season of its emission. Infrared absorption spectra of (E) CF3CH=CHCF3 were measured and used to estimate the 100-year time horizon global warming potentials (GWP) of 32 (atmospherically well-mixed) and 14 (lifetime-adjusted).

  18. Optical method for measuring thermal accommodation coefficients using a whispering-gallery microresonator.

    Science.gov (United States)

    Ganta, D; Dale, E B; Rezac, J P; Rosenberger, A T

    2011-08-28

    A novel optical method has been developed for the measurement of thermal accommodation coefficients in the temperature-jump regime. The temperature dependence of the resonant frequency of a fused-silica microresonator's whispering-gallery mode is used to measure the rate at which the microresonator comes into thermal equilibrium with the ambient gas. The thermal relaxation time is related to the thermal conductivity of the gas under some simplifying assumptions and measuring this time as a function of gas pressure determines the thermal accommodation coefficient. Using a low-power tunable diode laser of wavelength around 1570 nm to probe a microsphere's whispering-gallery mode through tapered-fiber coupling, we have measured the accommodation coefficients of air, helium, and nitrogen on fused silica at room temperature. In addition, by applying thin-film coatings to the microsphere's surface, we have demonstrated that accommodation coefficients can be measured for various gases on a wide range of modified surfaces using this method. © 2011 American Institute of Physics

  19. Low level optical absorption measurements on organic semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Stella, M.; Rojas, F.; Escarre, J.; Asensi, J.M.; Bertomeu, J.; Andreu, J. [Dept. de Fisica Aplicada i Optica, Universitat de Barcelona. Av. Diagonal 647, 08028 Barcelona (Spain); Voz, C.; Puigdollers, J.; Fonrodona, M. [Micro and Nano Technology Group (MNT), Dept. d' Enginyeria Electronica, Universitat Politecnica de Catalunya, C/Jordi Girona 1-3, Campus Nord - Modul C4, 08034 Barcelona (Spain)

    2006-06-15

    The optical absorption of n-type (C{sub 60} and PTCDA) and p-type (CuPc and pentacene) organic semiconductors is investigated by optical transmission and photothermal deflection spectroscopy. The usual absorption bands related to HOMO-LUMO transitions are observed in the high absorption region of transmission spectra. Photothermal deflection spectroscopy also evidences exponential absorption shoulders with characteristic energies 47meV for CuPc, 38meV for pentacene, 50 meV for PTCDA and 87meV for C{sub 60}. In addition, broad bands in the low absorption level are observed for C{sub 60} and PTCDA. These bands have been attributed to contamination due to air exposure. On the other hand, in CuPc a clear absorption peak at 1.12eV is observed with smaller features at 1.04eV, 1.20eV and 1.33eV. These peaks are attributed to transitions between the Pc levels of CuPc ions. Finally, the optical absorption expected in blends of organic semiconductors is estimated by an effective media approximation. (author)

  20. Exploring Capacitance-Voltage measurements to find the Piezoelectric Coefficient of Aluminum Nitride

    NARCIS (Netherlands)

    van Hemert, T.; Sakriotis, D.; Hueting, Raymond Josephus Engelbart; Schmitz, Jurriaan

    2011-01-01

    In this work we explore an uncommon method to extract the piezoelectric coefficient of the piezoelectric material aluminum nitride. The method exploits the bias dependence of CV (capacitance voltage) measurements on M_M (metal-piezoelectric-metal) capacitors. We propose a bias dependent capacitance

  1. Experimental Determination of Drug Diffusion Coefficients in Unstirred Aqueous Environments by Temporally Resolved Concentration Measurements.

    Science.gov (United States)

    di Cagno, Massimiliano Pio; Clarelli, Fabrizio; Våbenø, Jon; Lesley, Christina; Rahman, Sokar Darsim; Cauzzo, Jennifer; Franceschinis, Erica; Realdon, Nicola; Stein, Paul C

    2018-04-02

    The diffusion coefficient (also known as diffusivity) of an active pharmaceutical ingredient (API) is a fundamental physicochemical parameter that affects passive diffusion through biological barriers and, as a consequence, bioavailability and biodistribution. However, this parameter is often neglected, and it is quite difficult to find diffusion coefficients of small molecules of pharmaceutical relevance in the literature. The available methods to measure diffusion coefficients of drugs all suffer from limitations that range from poor sensitivity to high selectivity of the measurements or the need for dedicated instrumentation. In this work, a simple but reliable method based on time-resolved concentration measurements by UV-visible spectroscopy in an unstirred aqueous environment was developed. This method is based on spectroscopic measurement of the variation of the local concentration of a substance during spontaneous migration of molecules, followed by standard mathematical treatment of the data in order to solve Fick's law of diffusion. This method is extremely sensitive and results in highly reproducible data. The technique was also employed to verify the influence of the environmental characteristics (i.e., ionic strength and presence of complexing agents) on the diffusivity. The method can be employed in any research laboratory equipped with a standard UV-visible spectrophotometer and could become a useful and straightforward tool in order to characterize diffusion coefficients in physiological conditions and help to better understand the drug permeability process.

  2. Measuring temperature coefficient of TRIGA MARK I reactor by noise analysis

    International Nuclear Information System (INIS)

    Soares, P.A.

    1975-01-01

    The transfer function of TRIGA MARK I Reactor is measured at power zero (5w) and power 118Kw, in the frequency range of 0.02 to 0.5 rd/s. The method of intercorrelation between a pseudostochasticbinary signal is used. A simple dynamic model of the reactor is developed and the coefficient of temperature is estimated [pt

  3. A novel method measuring optical fiber nonlinear coefficient based on XPM

    Science.gov (United States)

    Zhang, Shuangxi; Wu, Xuqiang; Ai, Fei; Zhang, Chengmei; Zhang, Bo; Yu, Benli

    2009-11-01

    In optic communication systems, the nonlinear effect of the optical fiber is of great importance. There are several methods measuring optical fiber nonlinear coefficient. A novel method measuring optical fiber nonlinear coefficient is proposed, which is based on a Mach-Zehnder interferometer fabricated with 3×3 coupler, polarization controller and so on. According to cross phase modulation (XPM), when two optical waves are injected into the same optical fiber, the phase of one optical wave will be changed because of the other one. So a sinusoidal phase signal will be generated through coupling a sinusoidal modulated high-power laser into one arm of the interferometer, and then the three outputs of the interferometer will contain the sinusoidal phase signal. According to the characteristic of the 3×3 coupler, the phase difference between the three outputs is 2π / 3 . Through mathematics disposition of the three outputs of the interferometer, a couple of orthogonal signals can be yielded. Then the amplitude of the sinusoidal phase signal can be demodulated accurately by arctan method. The length of the optical fiber and the power of the laser can be measured easily, according to expression about the nonlinear phase shift induced by XPM, the optical fiber nonlinear coefficient of certain wavelength will be calculated. The optical fiber nonlinear effect is simulated by the software optisystem, and the process measuring the optical fiber nonlinear coefficient is analyzed in detail based on the schematic design.

  4. Environmental coefficients of the free-field sensitivity of measurement microphones

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Cutanda Henriquez, Vicente; Torras-Rosell, Antoni

    2017-01-01

    The sensitivity of measurement microphones, both pressure and free field, is affected by changes in the environmental conditions, mainly temperature and static pressure. Static pressure and temperature coefficients for the pressure sensitivity have been the object of previous studies focused on L...

  5. Measurements of the Absorptive Properties of the Ionosphere

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Absorption of radio waves occurs when electrons responding to the wave fields collide with and transfer energy to the neutral particles. A study of ionospheric...

  6. The measurement of friction coefficient down to 1.8 K for LHC Magnets

    CERN Document Server

    Artoos, K; Poncet, Alain; Savary, F; Veness, R J M

    1994-01-01

    The Large Hadron Collider (LHC) proposed for construction at CERN consists of a series of high field superconducting dipole magnet operating at 1.8K. The mechanical structure of these magnets contains many components in close contact. A knowledge of the friction coefficient between these components is required. Indeed, during assembly and cool down of the magnets, prestresses must be transferred to the superconducting coils. During operation, frictional heating may provoke loss of superconductivity. A machine has been built at CERN to measure the coefficient of friction from room temperature down to 1.8K. This paper describes the cryogenic tribometer and the results collected to date.

  7. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    CERN Document Server

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  8. Exciton diffusion coefficient measurement in ZnO nanowires under electron beam irradiation

    Science.gov (United States)

    Donatini, Fabrice; Pernot, Julien

    2018-03-01

    In semiconductor nanowires (NWs) the exciton diffusion coefficient can be determined using a scanning electron microscope fitted with a cathodoluminescence system. High spatial and temporal resolution cathodoluminescence experiments are needed to measure independently the exciton diffusion length and lifetime in single NWs. However, both diffusion length and lifetime can be affected by the electron beam bombardment during observation and measurement. Thus, in this work the exciton lifetime in a ZnO NW is measured versus the electron beam dose (EBD) via a time-resolved cathodoluminescence experiment with a temporal resolution of 50 ps. The behavior of the measured exciton lifetime is consistent with our recent work on the EBD dependence of the exciton diffusion length in similar NWs investigated under comparable SEM conditions. Combining the two results, the exciton diffusion coefficient in ZnO is determined at room temperature and is found constant over the full span of EBD.

  9. Consequences of using home-made radon sources for measuring the radon diffusion coefficient

    International Nuclear Information System (INIS)

    Dobrovolny, T.; Jiranek, M.

    2017-01-01

    The applicability of home-made radon sources for determining the radon diffusion coefficient of waterproofing materials was studied for three representatives of materials with a high radium content: uraninite, slag concrete and filter sand. The results of our investigation confirmed that the radon production rate of home-made radon sources is significantly lower than the radon production rate of artificial sources. Consequently, home-made sources are usually unable to generate concentrations higher than 100 kBq/m 3 in the source container. Therefore, they cannot be used for determining radon diffusion coefficients lower than 1 x 10 -12 m 2 /s. In addition, when home-made radon sources are used, only time-dependent mathematical solutions of the non-stationary radon diffusion can be used for determining the radon diffusion coefficient from the measured data. (authors)

  10. Measurement of Turbulent Skin Friction Drag Coefficients Produced by Distributed Surface Roughness of Pristine Marine Coatings

    DEFF Research Database (Denmark)

    Zafiryadis, Frederik; Meyer, Knud Erik; Gökhan Ergin, F.

    Skin friction drag coefficients are determined for marine antifouling coatings in pristine condition by use of Constant Temperature Anemometry (CTA) with uni-directionalhot-wires. Mean flow behaviour for varying surface roughness is analysed in zero pressure gradient, flat plate, turbulentboundary...... drag coefficients as well as roughness Reynolds numbers for the various marine coatings across the range of Rex by fitting of the van Driest profile. The results demonstrate sound agreement with the present ITTC method for determining skin friction coefficients for practically smooth surfaces at low...... layers for Reynolds numbers from Rex =1:91x105 to Rex = 9:54x105. The measurements were conducted at the Technical University of Denmark in a closed-loop wind tunnel redesigned for investigations as this. Ensemble averages of the boundary layer velocity profiles allowed for determination of skin friction...

  11. Discharge Coefficient Measurements for Flow Through Compound-Angle Conical Holes with Cross-Flow

    Directory of Open Access Journals (Sweden)

    M. E. Taslim

    2004-01-01

    Full Text Available Diffusion-shaped film holes with compound angles are currently being investigated for high temperature gas turbine airfoil film cooling. An accurate prediction of the coolant blowing rate through these film holes is essential in determining the film effectiveness. Therefore, the discharge coefficients associated with these film holes for a range of hole pressure ratios is essential in designing airfoil cooling circuits. Most of the available discharge coefficient data in open literature has been for cylindrical holes. The main objective of this experimental investigation was to measure the discharge coefficients for subsonic as well as supersonic pressure ratios through a single conical-diffusion hole. The conical hole has an exit-to-inlet area ratio of 4, a nominal flow length-to-inlet diameter ratio of 4, and an angle with respect to the exit plane (inclination angle of 0°, 30°, 45°, and 60°. Measurements were performed with and without a cross-flow. For the cases with a cross-flow, discharge coefficients were measured for each of the hole geometries and 5 angles between the projected conical hole axis and the cross-flow direction of 0°, 45°, 90°, 135°, and 180°. Results are compared with available data in open literature for cylindrical film holes as well as limited data for conical film holes.

  12. Temperature dependent absorption measurement of various transition metal doped laser materials

    Science.gov (United States)

    Horackova, Lucie; Šulc, Jan; Jelinkova, Helena; Jambunathan, Venkatesan; Lucianetti, Antonio; Mocek, Tomás.

    2015-05-01

    In recent years, there has been a vast development of high energy class lasers of the order of 100 J to kJ level which have potential applications in the field of science and technology. Many such systems use the gain media cooled at cryogenic temperatures which will help in enhancing the spectroscopic and thermo-optical properties. Nevertheless, parasitic effects like amplified spontaneous emission enhance and affect the overall efficiency. The best way to suppress this effect is to use cladding element attached to the gain material. Based on these facts, this work was focused on the systematic investigation of temperature dependent absorption of several materials doped with transition metals, which can be used as cladding, as laser gain material, or as passive Q-switching element. The Ti:sapphire, Cr:YAG, V:YAG, and Co:MALO samples were measured in temperature range from 80 K to 330 K by step of 50 K. Using Beer-Lambert law we estimated the absorption coefficient of these materials.

  13. Water vapor measurements in the 0.94 micron absorption band - Calibration, measurements and data applications

    Science.gov (United States)

    Reagan, J. A.; Thome, K.; Herman, B.; Gall, R.

    1987-01-01

    This paper describes methods and presents results for sensing the columnar content of atmospheric water vapor via differential solar transmission measurements in and adjacent to the 0.94-micron water-vapor absorption band. Calibration and measurement techniques are presented for obtaining the water vapor transmission from the radiometer measurements. Models are also presented for retrieving the columnar water vapor amount from the estimated transmission. Example retrievals are presented for radiometer measurements made during the 1986 Arizona Monsoon Season to track temporal variations in columnar water vapor amount.

  14. Novel Instrument to Measure Aerosol Fluorescence, Absorption, and Scattering, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Picarro, Inc proposes to develop the first cavity ringdown spectroscopy (CRDS) system to measure fluorescence, absorption, and scattering properties of atmospheric...

  15. Dynamic Optoelectronic Properties in Perovskite Oxide Thin Films Measured with Ultrafast Transient Absorption & Reflectance Spectroscopy

    Science.gov (United States)

    Smolin, Sergey Y.

    -derived static spectra of LaFeO3, we find that thermal contributions dominate the transient absorption and reflectance spectra above the band gap. A transient photoinduced absorption feature below the band gap at 1.9 eV is not reproduced in the thermally derived spectra and has significantly longer decay kinetics from the thermallyinduced features; therefore, this long lived photoinduced absorption is likely derived, at least partially, from photoexcited carriers with lifetimes much longer than 3 nanoseconds. LaFeO3 has a wide band gap of 2.4 eV but its absorption can be decreased with chemical substitution of Sr for Fe to make it more suitable for various applications. This type of A-site substitution is a common route to change static optical absorption in perovskite oxides, but there are no systematic studies looking at how A-site substitution changes dynamic optoelectronic properties. To understand the relationship between composition and static and dynamic optical properties we worked with the model system of La1-xSrxFeO 3-delta epitaxial films grown on LSAT, uncovering the effects of A-site cation substitution and oxygen stoichiometry. Variable-angle spectroscopic ellipsometry was used to measure static optical properties, revealing a linear increase in absorption coefficient at 1.25 eV and a red-shifting of the optical absorption edge with increasing Sr fraction. The absorption spectra can be similarly tuned through the introduction of oxygen vacancies, indicating the critical role that nominal Fe valence plays in optical absorption. Dynamic optoelectronic properties were studied with ultrafast transient reflectance spectroscopy with broadband visible (1.6 eV to 4 eV) and near-infrared (0.9 eV to 1.5 eV) probes. The sign of the reflectance change in the near-infrared region in LSFO is indicative of carrier bandfilling of newly created electronic states by photoexcited carriers. Moreover, we find that similar transient spectral trends can be induced with A

  16. Comparison of radon diffusion coefficients measured by transient-diffusion and steady-state laboratory methods

    International Nuclear Information System (INIS)

    Kalwarf, D.R.; Nielson, K.K.; Rich, D.C.; Rogers, V.C.

    1982-11-01

    A method was developed and used to determine radon diffusion coefficients in compacted soils by transient-diffusion measurements. A relative standard deviation of 12% was observed in repeated measurements with a dry soil by the transient-diffusion method, and a 40% uncertainty was determined for moistures exceeding 50% of saturation. Excellent agreement was also obtained between values of the diffusion coefficient for radon in air, as measured by the transient-diffusion method, and those in the published literature. Good agreement was also obtained with diffusion coefficients measured by a steady-state method on the same soils. The agreement was best at low moistures, averaging less than ten percent difference, but differences of up to a factor of two were observed at high moistures. The comparison of the transient-diffusion and steady-state methods at low moistures provides an excellent verification of the theoretical validity and technical accuracy of these approaches, which are based on completely independent experimental conditions, measurement methods and mathematical interpretations

  17. Tail-weighted dependence measures with limit being the tail dependence coefficient

    KAUST Repository

    Lee, David

    2017-12-02

    For bivariate continuous data, measures of monotonic dependence are based on the rank transformations of the two variables. For bivariate extreme value copulas, there is a family of estimators (Formula presented.), for (Formula presented.), of the extremal coefficient, based on a transform of the absolute difference of the α power of the ranks. In the case of general bivariate copulas, we obtain the probability limit (Formula presented.) of (Formula presented.) as the sample size goes to infinity and show that (i) (Formula presented.) for (Formula presented.) is a measure of central dependence with properties similar to Kendall\\'s tau and Spearman\\'s rank correlation, (ii) (Formula presented.) is a tail-weighted dependence measure for large α, and (iii) the limit as (Formula presented.) is the upper tail dependence coefficient. We obtain asymptotic properties for the rank-based measure (Formula presented.) and estimate tail dependence coefficients through extrapolation on (Formula presented.). A data example illustrates the use of the new dependence measures for tail inference.

  18. Characterization of thin poly(dimethylsiloxane)-based tissue-simulating phantoms with tunable reduced scattering and absorption coefficients at visible and near-infrared wavelengths.

    Science.gov (United States)

    Greening, Gage J; Istfan, Raeef; Higgins, Laura M; Balachandran, Kartik; Roblyer, Darren; Pierce, Mark C; Muldoon, Timothy J

    2014-01-01

    Optical phantoms are used in the development of various imaging systems. For certain applications, the development of thin phantoms that simulate the physical size and optical properties of tissue is important. Here, we demonstrate a method for producing thin phantom layers with tunable optical properties using poly(dimethylsiloxane) (PDMS) as a substrate material. The thickness of each layer (between 115 and 880 μm) was controlled using a spin coater. The reduced scattering and absorption coefficients were controlled using titanium dioxide and alcohol-soluble nigrosin, respectively. These optical coefficients were quantified at six discrete wavelengths (591, 631, 659, 691, 731, and 851 nm) at varying concentrations of titanium dioxide and nigrosin using spatial frequency domain imaging. From the presented data, we provide lookup tables to determine the appropriate concentrations of scattering and absorbing agents to be used in the design of PDMS-based phantoms with specific optical coefficients. In addition, heterogeneous phantoms mimicking the layered features of certain tissue types may be fabricated from multiple stacked layers, each with custom optical properties. These thin, tunable PDMS optical phantoms can simulate many tissue types and have broad imaging calibration applications in endoscopy, diffuse optical spectroscopic imaging, and optical coherence tomography, etc.

  19. In situ gas temperature measurements by UV-absorption spectroscopy

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    2009-01-01

    The absorption spectrum of the NO A(2)Sigma(+) <- X(2)Pi gamma-system can be used for in situ evaluation of gas temperature. Experiments were performed with a newly developed atmospheric-pressure high-temperature flow gas cell at highly uniform and stable gas temperatures over a 0.533 m path in t....... The accuracy of both methods is discussed. Validation of the classical Lambert-Beer law has been demonstrated at NO concentrations up to 500 ppm and gas temperatures up to 1,500 degrees C over an optical absorption path length of 0.533 m....

  20. Prediction of transmission, reflection and absorption coefficients of periodic structures using a hybrid Wave Based - Finite Element unit cell method

    Science.gov (United States)

    Deckers, Elke; Jonckheere, Stijn; Van Belle, Lucas; Claeys, Claus; Desmet, Wim

    2018-03-01

    This paper presents a hybrid Wave Based Method - Finite Element unit cell method to predict the absorption, reflection and transmission properties of arbitrary, two-dimensional periodic structures. The planar periodic structure, represented by its unit cell combined with Bloch-Floquet periodicity boundary conditions, is modelled within the Finite Element Method, allowing to represent complex geometries and to include any type of physics. The planar periodic structure is coupled to semi-infinite acoustic domains above and/or below, in which the dynamic pressure field is modelled with the Wave Based Method, applying a wave function set that fulfills the Helmholtz equation and satisfies the Sommerfeld radiation condition and the Bloch-Floquet periodicity conditions inherently. The dynamic fields described within both frameworks are coupled using a direct coupling strategy, accounting for the mutual dynamic interactions via a weighted residual formulation. The method explicitly accounts for the interaction between the unit cell and the surrounding acoustic domain, also accounting for higher order periodic waves. The convergence of the method is analysed and its applicability is shown for a variety of problems, proving it to be a useful tool combining the strengths of two methods.

  1. Improvements to water vapor transmission and capillary absorption measurements in porous materials

    Science.gov (United States)

    Samuel L. Zelinka; Samuel V. Glass; Charles R. Boardman

    2016-01-01

    The vapor permeability (or equivalently the vapor diffusion resistance factor) and the capillary absorption coefficient are frequently used as inputs to hygrothermal or heat, air, and moisture (HAM) models. However, it has been well documented that the methods used to determine these properties are sensitive to the operator, and wide variations in the properties have...

  2. Midinfrared absorption measured at a lambda/400 resolution with an atomic force microscope.

    Science.gov (United States)

    Houel, Julien; Homeyer, Estelle; Sauvage, Sébastien; Boucaud, Philippe; Dazzi, Alexandre; Prazeres, Rui; Ortéga, Jean-Michel

    2009-06-22

    Midinfrared absorption can be locally measured using a detection combining an atomic force microscope and a pulsed excitation. This is illustrated for the midinfrared bulk GaAs phonon absorption and for the midinfrared absorption of thin SiO(2) microdisks. We show that the signal given by the cantilever oscillation amplitude of the atomic force microscope follows the spectral dependence of the bulk material absorption. The absorption spatial resolution achieved with microdisks is around 50 nanometer for an optical excitation around 22 micrometer wavelength.

  3. Dynamic Calibration and Verification Device of Measurement System for Dynamic Characteristic Coefficients of Sliding Bearing

    Science.gov (United States)

    Chen, Runlin; Wei, Yangyang; Shi, Zhaoyang; Yuan, Xiaoyang

    2016-01-01

    The identification accuracy of dynamic characteristics coefficients is difficult to guarantee because of the errors of the measurement system itself. A novel dynamic calibration method of measurement system for dynamic characteristics coefficients is proposed in this paper to eliminate the errors of the measurement system itself. Compared with the calibration method of suspension quality, this novel calibration method is different because the verification device is a spring-mass system, which can simulate the dynamic characteristics of sliding bearing. The verification device is built, and the calibration experiment is implemented in a wide frequency range, in which the bearing stiffness is simulated by the disc springs. The experimental results show that the amplitude errors of this measurement system are small in the frequency range of 10 Hz–100 Hz, and the phase errors increase along with the increasing of frequency. It is preliminarily verified by the simulated experiment of dynamic characteristics coefficients identification in the frequency range of 10 Hz–30 Hz that the calibration data in this frequency range can support the dynamic characteristics test of sliding bearing in this frequency range well. The bearing experiments in greater frequency ranges need higher manufacturing and installation precision of calibration device. Besides, the processes of calibration experiments should be improved. PMID:27483283

  4. Extending differential optical absorption spectroscopy for limb measurements in the UV

    Directory of Open Access Journals (Sweden)

    J. Puķīte

    2010-05-01

    Full Text Available Methods of UV/VIS absorption spectroscopy to determine the constituents in the Earth's atmosphere from measurements of scattered light are often based on the Beer-Lambert law, like e.g. Differential Optical Absorption Spectroscopy (DOAS. While the Beer-Lambert law is strictly valid for a single light path only, the relation between the optical depth and the concentration of any absorber can be approximated as linear also for scattered light observations at a single wavelength if the absorption is weak. If the light path distribution is approximated not to vary with wavelength, also linearity between the optical depth and the product of the cross-section and the concentration of an absorber can be assumed. These assumptions are widely made for DOAS applications for scattered light observations.

    For medium and strong absorption of scattered light (e.g. along very long light-paths like in limb geometry the relation between the optical depth and the concentration of an absorber is no longer linear. In addition, for broad wavelength intervals the differences in the travelled light-paths at different wavelengths become important, especially in the UV, where the probability for scattering increases strongly with decreasing wavelength.

    However, the DOAS method can be extended to cases with medium to strong absorptions and for broader wavelength intervals by the so called air mass factor modified (or extended DOAS and the weighting function modified DOAS. These approaches take into account the wavelength dependency of the slant column densities (SCDs, but also require a priori knowledge for the air mass factor or the weighting function from radiative transfer modelling.

    We describe an approach that considers the fitting results obtained from DOAS, the SCDs, as a function of wavelength and vertical optical depth and expands this function into a Taylor series of both quantities. The Taylor coefficients are then applied as

  5. Measurements of the electron particle diffusion coefficient with the JET multichannel reflectometer

    International Nuclear Information System (INIS)

    Sips, A.C.C.; Haas, J.C.M. de; Costley, A.E.; Prentice, R.

    1989-01-01

    Experimental determinations of the cross-field particle diffusion coefficient (D p ) are important in studies of transport in tokamak plasmas. D p has been determined from measurements of density perturbations following a sawtooth collapse, oscillating gas puff, and injected high velocity pellets. In each case the density changes have been measured using multichord interferometry and D p is obtained with an accuracy of typically 20%. In this paper, we present our most recent measurements of D p . The experimental data are compared with the prediction of a comprehensive numerical transport model which includes both outward going and inward going density pulses. (author) 8 refs., 6 figs

  6. Simultaneous measurement of thermo-optic and thermal expansion coefficients with a single arm double interferometer.

    Science.gov (United States)

    Domenegueti, Jose Francisco Miras; Andrade, Acacio A; Pilla, Viviane; Zilio, Sergio Carlos

    2017-01-09

    A low-cost single arm double interferometer was developed for the concurrent measurement of linear thermal expansion (α) and thermo-optic (dn/dT) coefficients of transparent samples with plane and parallel surfaces. Owing to its common-path optical arrangement, the device is compact and stable, and allows the simultaneous measurement of interferences arising from a low-finesse Fabry-Perot etalon and from a Mach-Zehnder-type interferometer. The method was demonstrated with measurements of solid (silica, BK7, SF6) and liquid (water, ethanol and acetone) samples.

  7. Measurement of activity coefficients of mixtures by head-space gas chromatography: general procedure.

    Science.gov (United States)

    Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I

    2013-08-09

    Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Water absorption tests for measuring permeability of field concrete.

    Science.gov (United States)

    2013-09-01

    The research results from CFIRE Project 04-06 were communicated to engineers and researchers in this project. : Specifically, the water absorption of concrete samples (i.e., 2-in. thick, 4-in. diameter discs cut from concrete : cylinders) was found s...

  9. Measurements of the fuel temperature coefficient of reactivity at Hinkley Point 'B': 1981

    International Nuclear Information System (INIS)

    George, T.A.

    1982-03-01

    Measurements of the fuel temperature coefficient of reactivity made at Hinkley Point 'B' AGR in 1981 are described. These measurements follow earlier tests reported in e.g. RD/B/N4846 and are part of a series of measurements designed to support theoretical estimates of the change of fuel temperature coefficient as a function of core irradiation. Low and high power measurements were made at a mean core irradiation of 1170GWD. As previously, the measurements at both power levels show agreement with theoretical predictions to within the estimated experimental errors. Recent measurements (mean core irradiation >500GWD) show evidence of a small systematic difference between measured and theoretical values with the experimental values being approximately equal to 0.1mN/ 0 C more positive than the theoretical ones. The measured value of αsub(U) at high power was -0.64+-0.10mN/ 0 C and the low power value, corrected theoretically to normal operating conditions, was also -0.64+-0.10mN/ 0 C. (author)

  10. Measurements of complex coupling coefficients in a ring resonator of a laser gyroscope

    Science.gov (United States)

    Bessonov, A. S.; Makeev, A. P.; Petrukhin, E. A.

    2017-07-01

    A method is proposed for measuring complex coupling coefficients in a ring optical resonator in the absence of an active gas mixture. A setup is described on which measurements are performed in ring resonators of ring He-Ne lasers with a wavelength of 632.8 nm. A model of backscattering field interference between conservative and dissipative sources is presented. Within the framework of this model, the unusual behaviour of backscattering fields in ring resonators observed in experiments is explained: a significant difference in the moduli of coupling coefficients of counterpropagating waves and variation of the magnitude of the total phase shift in a wide range. It is proposed to use this method as a metrological method when assembling and aligning a ring resonator of a laser gyroscope.

  11. Interaction between lactose and cadmium chloride in aqueous solutions as seen by diffusion coefficients measurements

    International Nuclear Information System (INIS)

    Verissimo, Luis M.P.; Gomes, Joselaine C.S.; Romero, Carmen; Esteso, Miguel A.; Sobral, Abilio J.F.N.; Ribeiro, Ana C.F.

    2013-01-01

    Highlights: ► Diffusion coefficients of aqueous systems containing lactose and cadmium chloride. ► Influence of the lactose on the diffusion of cadmium chloride. ► Interactions between Cd 2+ and lactose. -- Abstract: Diffusion coefficients of an aqueous system containing cadmium chloride 0.100 mol · dm −3 and lactose at different concentrations at 25 °C have been measured, using a conductimetric cell and an automatic apparatus to follow diffusion. The cell relies on an open-ended capillary method and a conductimetric technique is used to follow the diffusion process by measuring the resistance of a solution inside the capillaries, at recorded times. From these results and by ab initio calculations, it was possible to obtain a better understanding of the effect of lactose on transport of cadmium chloride in aqueous solutions

  12. Measurements of fuel temperature coefficient of reactivity on a commercial AGR

    International Nuclear Information System (INIS)

    Telford, A.; Bridge, M.J.

    1978-01-01

    Tests have been carried out on the commercial AGR at Hikley Point to determine the fuel temperature coefficient of reactivity, an important safety related parameter. Reactor neutron flux was measured during transients induced by movement of a bank of control rods from one steady position to another. An inverse kinetics analysis was applied to the measured flux to determine the change which occured in core reactivity as the fuel temperature changed. The variation of mean fuel temperature was deduced from the flux transient by means of a nine-plane thermal hydraulics representation of the AGR fuel channel. Results so far obtained confirm the predicted variation of fuel temperature coefficient with butn-up. (author)

  13. Measurement of the local particle diffusion coefficient in a magnetized plasma

    International Nuclear Information System (INIS)

    Meyerhofer, D.D.; Levinton, F.M.

    1987-02-01

    Local impurity particle diffusion coefficients have been measured in a low temperature plasma by the injection of test particles at the center of the plasma. The injection is accomplished by a high voltage discharge between two small graphite electrodes on a probe. The probe can be located anywhere in the plasma. The diffusion is observed spectroscopically. An analysis of the spatial and temporal evolution of the CII radiation from the carbon discharge can determine the parallel and perpendicular diffusion of the impurity ions. Results with the diagnostic have been obtained in the Proto S-1/C spheromak. The measured value of the diffusion coefficient in the afterglow plasma is in good agreement with classical predictions

  14. Home built equipment for measuring Hall coefficient and charge carrier concentration, mobility and resistivity

    DEFF Research Database (Denmark)

    Borup, Kasper Andersen; Christensen, Mogens; Blichfeld, Anders Bank

    2011-01-01

    We present here a home built setup for measuring the specific resistivity, hall coefficient, and charge carrier concentration and mobility at elevated temperatures. The system is optimized for measurements of samples ranging between doped semiconductors and high resistivity metals and uses the van...... der Pauw method. The commercial availability of these systems is limited and they are usually not optimized for measurements on samples which show properties characteristic of thermoelectric materials. We give an assessment of the reliability of the measurements and a comparison with a commercial...... system, the Quantum Design, Physical Properties Measurement System (PPMS). Measurements on samples with different resistivity and charge carrier concentration will be shown, covering both ends of the interval of samples we are able to measure as well as the range normally observed for thermoelectrics...

  15. The method of solution of equations with coefficients that contain measurement errors, using artificial neural network.

    Science.gov (United States)

    Zajkowski, Konrad

    This paper presents an algorithm for solving N -equations of N -unknowns. This algorithm allows to determine the solution in a situation where coefficients A i in equations are burdened with measurement errors. For some values of A i (where i  = 1,…, N ), there is no inverse function of input equations. In this case, it is impossible to determine the solution of equations of classical methods.

  16. Effective diffusion coefficients for methanol in sulfuric acid solutions measured by Raman spectroscopy.

    Science.gov (United States)

    Van Loon, Lisa L; Allen, Heather C; Wyslouzil, Barbara E

    2008-10-30

    The diffusion of methanol into 0-96.5 wt % sulfuric acid solutions was followed using Raman spectroscopy. Because methanol reacts to form protonated methanol (CH 3OH 2 (+)) and methyl hydrogen sulfate in H 2SO 4 solutions, the reported diffusion coefficients, D, are effective diffusion coefficients that include all of the methyl species diffusing into H 2SO 4. The method was first verified by measuring D for methanol into water. The value obtained here, D = (1.4 +/- 0.6) x 10 (-5) cm (2)/s, agrees well with values found in the literature. The values of D in 39.2-96.5 wt % H 2SO 4 range from (0.11-0.3) x 10 (-5) cm (2)/s, with the maximum value of D occurring for 61.6 wt % H 2SO 4. The effective diffusion coefficients do not vary systematically with the viscosity of the solutions, suggesting that the speciation of both methanol and sulfuric acid may be important in determining these transport coefficients.

  17. Measuring the Coefficient of Friction of a Small Floating Liquid Marble.

    Science.gov (United States)

    Ooi, Chin Hong; Nguyen, Anh Van; Evans, Geoffrey M; Dao, Dzung Viet; Nguyen, Nam-Trung

    2016-12-02

    This paper investigates the friction coefficient of a moving liquid marble, a small liquid droplet coated with hydrophobic powder and floating on another liquid surface. A floating marble can easily move across water surface due to the low friction, allowing for the transport of aqueous solutions with minimal energy input. However, the motion of a floating marble has yet to be systematically characterised due to the lack of insight into key parameters such as the coefficient of friction between the floating marble and the carrier liquid. We measured the coefficient of friction of a small floating marble using a novel experimental setup that exploits the non-wetting properties of a liquid marble. A floating liquid marble pair containing a minute amount magnetite particles were immobilised and then released in a controlled manner using permanent magnets. The capillarity-driven motion was analysed to determine the coefficient of friction of the liquid marbles. The "capillary charge" model was used to fit the experimental results. We varied the marble content and carrier liquid to establish a relationship between the friction correction factor and the meniscus angle.

  18. Employing the Gini coefficient to measure participation inequality in treatment-focused Digital Health Social Networks.

    Science.gov (United States)

    van Mierlo, Trevor; Hyatt, Douglas; Ching, Andrew T

    2016-01-01

    Digital Health Social Networks (DHSNs) are common; however, there are few metrics that can be used to identify participation inequality. The objective of this study was to investigate whether the Gini coefficient, an economic measure of statistical dispersion traditionally used to measure income inequality, could be employed to measure DHSN inequality. Quarterly Gini coefficients were derived from four long-standing DHSNs. The combined data set included 625,736 posts that were generated from 15,181 actors over 18,671 days. The range of actors (8-2323), posts (29-28,684), and Gini coefficients (0.15-0.37) varied. Pearson correlations indicated statistically significant associations between number of actors and number of posts (0.527-0.835, p  addiction networks (0.619 and 0.276, p  networks ( t  = -4.305 and -5.934, p  network engagement. Further, mixed-methods research investigating quantitative performance metrics is required.

  19. EPMA-EDS surface measurements of interdiffusion coefficients between miscible metals in thin films

    International Nuclear Information System (INIS)

    Christien, F.; Pierson, J.F.; Hassini, A.; Capon, F.; Le Gall, R.; Brousse, T.

    2010-01-01

    A new technique is developed to study interdiffusion between two miscible metals. The technique is applied to the Ni-Pd system. It consists in measuring the change of apparent surface composition of a Pd substrate coated with an 800 nm Ni thin film during annealing at a given temperature. The measurement is carried out in-situ inside the chamber of a SEM (scanning electron microscope) by EPMA-EDS (electron probe microanalysis-energy dispersive X-ray spectroscopy). The experimental data are processed using a model that mixes the Fick's diffusion equations and the electron probe microanalysis equation. This process allows the determination of the mean interdiffusion coefficient at a given annealing temperature. The main advantages of the technique are the possible determination of interdiffusion coefficients in thin films and at very low temperature (down to 430 deg. C, i.e. ∼0.4 T m ), which is not achievable with other techniques conventionally used for the study of interdiffusion. The Ni-Pd mean interdiffusion coefficient is shown to follow an Arrhenius law (D-tilde c =6.32x10 -3 exp((178.8kJmol -1 )/(RT) )cm 2 s -1 ) between 430 deg. C and 900 deg. C, in relatively good agreement with previous interdiffusion measurements made on the Ni-Pd system at higher temperature.

  20. Three-dimensional measurement of the local extinction coefficient in a dense spray

    International Nuclear Information System (INIS)

    Wellander, Rikard; Berrocal, Edouard; Kristensson, Elias; Richter, Mattias; Aldén, Marcus

    2011-01-01

    Laser extinction, signal attenuation and multiple scattering are the three main phenomena limiting qualitative and quantitative measurements in planar laser imaging of sprays. In this paper, a method is presented where structured laser illumination planar imaging is used to remove the signal contribution from multiply scattered light. Based on this technique, data from side scattering and transmission measurements are obtained simultaneously. An algorithm, compensating for signal attenuation and laser extinction, is further applied to calculate the local extinction coefficient. The method is first demonstrated on a cuvette containing a homogeneous solution of scattering particles with an extinction coefficient μ-bar e = 0.13 mm −1 . Finally the procedure is applied on an air-assisted water spray with a maximum optical depth of OD ∼ 3, where the position-dependent extinction coefficient is extracted within the probed volume. To the best of our knowledge, this paper demonstrates for the first time a method to measure the local μ-bar e within the three dimensions of an inhomogeneous scattering medium using laser sheet illumination, after suppression of the multiple light scattering intensity

  1. Airborne Measurements of CO2 Column Absorption and Range Using a Pulsed Direct-Detection Integrated Path Differential Absorption Lidar

    Science.gov (United States)

    Abshire, James B.; Riris, Haris; Weaver, Clark J.; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Browell, Edward V.

    2013-01-01

    We report on airborne CO2 column absorption measurements made in 2009 with a pulsed direct-detection lidar operating at 1572.33 nm and utilizing the integrated path differential absorption technique. We demonstrated these at different altitudes from an aircraft in July and August in flights over four locations in the central and eastern United States. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The lidar measurement statistics were also calculated for each flight as a function of altitude. The optical depth varied nearly linearly with altitude, consistent with calculations based on atmospheric models. The scatter in the optical depth measurements varied with aircraft altitude as expected, and the median measurement precisions for the column varied from 0.9 to 1.2 ppm. The altitude range with the lowest scatter was 810 km, and the majority of measurements for the column within it had precisions between 0.2 and 0.9 ppm.

  2. Airborne measurements of CO2 column absorption and range using a pulsed direct-detection integrated path differential absorption lidar.

    Science.gov (United States)

    Abshire, James B; Riris, Haris; Weaver, Clark J; Mao, Jianping; Allan, Graham R; Hasselbrack, William E; Browell, Edward V

    2013-07-01

    We report on airborne CO(2) column absorption measurements made in 2009 with a pulsed direct-detection lidar operating at 1572.33 nm and utilizing the integrated path differential absorption technique. We demonstrated these at different altitudes from an aircraft in July and August in flights over four locations in the central and eastern United States. The results show clear CO(2) line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. The lidar measurement statistics were also calculated for each flight as a function of altitude. The optical depth varied nearly linearly with altitude, consistent with calculations based on atmospheric models. The scatter in the optical depth measurements varied with aircraft altitude as expected, and the median measurement precisions for the column varied from 0.9 to 1.2 ppm. The altitude range with the lowest scatter was 8-10 km, and the majority of measurements for the column within it had precisions between 0.2 and 0.9 ppm.

  3. New Light Source Setup for Angle Resolved Light Absorption measurement of PV samples

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Poulsen, Peter Behrensdorff; Thorsteinsson, Sune

    Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light.......Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light....

  4. New Light Source Setup for Angle Resolved Light Absorption measurement of PV sample

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Poulsen, Peter Behrensdorff; Thorsteinsson, Sune

    Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light.......Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light....

  5. Measurement of off-diagonal transport coefficients in two-phase flow in porous media.

    Science.gov (United States)

    Ramakrishnan, T S; Goode, P A

    2015-07-01

    The prevalent description of low capillary number two-phase flow in porous media relies on the independence of phase transport. An extended Darcy's law with a saturation dependent effective permeability is used for each phase. The driving force for each phase is given by its pressure gradient and the body force. This diagonally dominant form neglects momentum transfer from one phase to the other. Numerical and analytical modeling in regular geometries have however shown that while this approximation is simple and acceptable in some cases, many practical problems require inclusion of momentum transfer across the interface. Its inclusion leads to a generalized form of extended Darcy's law in which both the diagonal relative permeabilities and the off-diagonal terms depend not only on saturation but also on the viscosity ratio. Analogous to application of thermodynamics to dynamical systems, any of the extended forms of Darcy's law assumes quasi-static interfaces of fluids for describing displacement problems. Despite the importance of the permeability coefficients in oil recovery, soil moisture transport, contaminant removal, etc., direct measurements to infer the magnitude of the off-diagonal coefficients have been lacking. The published data based on cocurrent and countercurrent displacement experiments are necessarily indirect. In this paper, we propose a null experiment to measure the off-diagonal term directly. For a given non-wetting phase pressure-gradient, the null method is based on measuring a counter pressure drop in the wetting phase required to maintain a zero flux. The ratio of the off-diagonal coefficient to the wetting phase diagonal coefficient (relative permeability) may then be determined. The apparatus is described in detail, along with the results obtained. We demonstrate the validity of the experimental results and conclude the paper by comparing experimental data to numerical simulation. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Analyses of Spring Barley Evapotranspiration Rates Based on Gradient Measurements and Dual Crop Coefficient Model

    Directory of Open Access Journals (Sweden)

    Gabriela Pozníková

    2014-01-01

    Full Text Available The yield of agricultural crops depends on water availability to a great extent. According some projections, the likelihood of stress caused by drought is increasing in future climates expected for the Central Europe. Therefore, in order to manage agro-ecosystems properly, it is necessary to know water demand of particular crops as precisely as possible. Evapotranspiration (ET is the main part of water balance which takes the water from agro-ecosystems away. The ET consists of evaporation from the soil (E and transpiration (T through the stomata of plants. In this study, we investigated ET of spring barley 1-ha field (Domanínek, Czech Republic measured by Bowen ratio/energy balance method during growing period 2013 (May 8 to July 31. Special focus was dedicated to comparison of barley ET with the reference grass ETo calculated according FAO-56 model, i.e. the determination of barley crop coefficient (Kc. This crop coefficient was subsequently separated into soil evaporation (Ke and transpiration fraction (Kcb by adjusting soil and phenological parameters of dual crop coefficient model to minimize the root mean square error between measured and modelled ET. The resulting Kcb of barley was 0.98 during mid-growing period and 0.05 during initial and end periods. According to FAO-56, typical values are 1.10 and 0.15 for Kcb mid and Kcb end, respectively. Modelled and measured ET show satisfactory agreement with root mean square error equal 0.41 mm. Based on the sums of ET and E for the whole growing season of the spring barley, ET partitioning by FAO-56 dual crop coefficient model resulted in E/ET ratio being 0.24.

  7. Evaluation of Systematic and Random Error in the Measurement of Equilibrium Solubility and Diffusion Coefficient for Liquids in Polymers

    National Research Council Canada - National Science Library

    Shuely, Wendel

    2001-01-01

    A standardized thermogravimetric analyzer (TGA) desorption method for measuring the equilibrium solubility and diffusion coefficient of toxic contaminants with polymers was further developed and evaluated...

  8. The activity of γ-emitters as measured by ionisation chambers the determination of the specific emission coefficient γ for some radio-elements (1961)

    International Nuclear Information System (INIS)

    Engelmann, J.

    1962-06-01

    The object of this work is to study techniques of measurement using the gamma ionisation chamber, making it possible either to measure the activities of radioactive sources, or to determine the specific emission coefficient γ (or the coefficient K) of a given radioelement. The ionisation chambers studied belong to two categories: graphites cavity-chambers, and 4 π γ chambers. For the cavity-chamber measurements, the different correction factors of which account must be taken have been calculated, in particular the geometric and hygrometric corrections. The absorption and auto-absorption corrections have led to the introduction of the notion of the 'effective energy γ' of a radioelement. In the case of 4 π γ chambers, it has been shown that appropriately shaped electrodes make it possible to improve their performances. One of the chambers described permits the measurement of β emitters using the associated Bremsstrahlung. In order to measure the K coefficient of some radioelements, it has been found useful a 4 π γ chamber with graphite walls, the measurement being carried out by comparison with a radium standard. The validity of the method was checked with radioelements for whom the K coefficient values are well-known ( 24 Na, 60 Co, 131 I, 198 Au). For other radioelements, the following values were obtained (expressed in r cm 3 mc -1 h -1 ): 51 Cr: 0,18; 56 Mn: 8,8; 65 Zn: 3,05; 124 Sb: 9,9; 134 Cs: 9,3; 137 Cs: 3,35; 141 Ce: 0,46; 170 Tm: 0,023; 192 Ir: 24,9; 203 Hg: 1,18; These values have been corrected for the contribution to the dose of the fluorescent radiation which may be emitted by the source, except in the case of Tm 170 . In the last part of this work, the performances of the different electro-metric devices used were compared. (author) [fr

  9. Nonlinear absorption coefficient and relative refraction index change for an asymmetrical double δ-doped quantum well in GaAs with a Schottky barrier potential

    Energy Technology Data Exchange (ETDEWEB)

    Rojas-Briseño, J.G.; Martínez-Orozco, J.C.; Rodríguez-Vargas, I. [Unidad Académica de Física, Universidad Autónoma de Zacatecas, Calzada Solidaridad esquina con Paseo la Bufa S/N, C.P. 98060, Zacatecas, Zac. (Mexico); Mora-Ramos, M.E. [Facultad de Ciencias, Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, CP 62209, Cuernavaca, Morelos (Mexico); Instituto de Física, Universidad de Antioquia, AA 1226, Medellín (Colombia); Duque, C.A., E-mail: cduque@fisica.udea.edu.co [Instituto de Física, Universidad de Antioquia, AA 1226, Medellín (Colombia)

    2013-09-01

    In this work we are reporting the energy level spectrum for a quantum system consisting of an n-type double δ-doped quantum well with a Schottky barrier potential in a Gallium Arsenide matrix. The calculated states are taken as the basis for the evaluation of the linear and third-order nonlinear contributions to the optical absorption coefficient and to the relative refractive index change, making particular use of the asymmetry of the potential profile. These optical properties are then reported as a function of the Schottky barrier height (SBH) and the separation distance between the δ-doped quantum wells. Also, the effects of the application of hydrostatic pressure are studied. The results show that the amplitudes of the resonant peaks are of the same order of magnitude of those obtained in the case of single δ-doped field effect transistors; but tailoring the asymmetry of the confining potential profile allows the control the resonant peak positions.

  10. Calculation procedure to determine average mass transfer coefficients in packed columns from experimental data for ammonia-water absorption refrigeration systems

    Energy Technology Data Exchange (ETDEWEB)

    Sieres, Jaime; Fernandez-Seara, Jose [University of Vigo, Area de Maquinas y Motores Termicos, E.T.S. de Ingenieros Industriales, Vigo (Spain)

    2008-08-15

    The ammonia purification process is critical in ammonia-water absorption refrigeration systems. In this paper, a detailed and a simplified analytical model are presented to characterize the performance of the ammonia rectification process in packed columns. The detailed model is based on mass and energy balances and simultaneous heat and mass transfer equations. The simplified model is derived and compared with the detailed model. The range of applicability of the simplified model is determined. A calculation procedure based on the simplified model is developed to determine the volumetric mass transfer coefficients in the vapour phase from experimental data. Finally, the proposed model and other simple calculation methods found in the general literature are compared. (orig.)

  11. Measurement and modeling of CO2 diffusion coefficient in Saline Aquifer at reservoir conditions

    Science.gov (United States)

    Azin, Reza; Mahmoudy, Mohamad; Raad, Seyed; Osfouri, Shahriar

    2013-12-01

    Storage of CO2 in deep saline aquifers is a promising techniques to mitigate global warming and reduce greenhouse gases (GHG). Correct measurement of diffusivity is essential for predicting rate of transfer and cumulative amount of trapped gas. Little information is available on diffusion of GHG in saline aquifers. In this study, diffusivity of CO2 into a saline aquifer taken from oil field was measured and modeled. Equilibrium concentration of CO2 at gas-liquid interface was determined using Henry's law. Experimental measurements were reported at temperature and pressure ranges of 32-50°C and 5900-6900 kPa, respectively. Results show that diffusivity of CO2 varies between 3.52-5.98×10-9 m2/s for 5900 kPa and 5.33-6.16×10-9 m2/s for 6900 kPa initial pressure. Also, it was found that both pressure and temperature have a positive impact on the measures of diffusion coefficient. Liquid swelling due to gas dissolution and variations in gas compressibility factor as a result of pressure decay was found negligible. Measured diffusivities were used model the physical model and develop concentration profile of dissolved gas in the liquid phase. Results of this study provide unique measures of CO2 diffusion coefficient in saline aquifer at high pressure and temperature conditions, which can be applied in full-field studies of carbon capture and sequestration projects.

  12. Absorption measurement s in InSe single crystal under an applied electric field

    International Nuclear Information System (INIS)

    Ates, A.; Guerbulak, B.; Guer, E.; Yildirim, T.; Yildirim, M.

    2002-01-01

    InSe single crystal was grown by Bridgman-Stockberger method. Electric field effect on the absorption measurements have been investigated as a function of temperature in InSe single crystal. The absorption edge shifted towards longer wavelengths and decreased of intensity in absorption spectra under an electric field. Using absorption measurements, Urbach energy was calculated under an electric field. Applied electric field caused a increasing in the Urbach energy. At 10 K and 320 K, the first exciton energies were calculated as 1.350 and 1.311 eV for zero voltage and 1.334 and 1.301 eV for electric field respectively

  13. TESTING BRAND VALUE MEASUREMENT METHODS IN A RANDOM COEFFICIENT MODELING FRAMEWORK

    Directory of Open Access Journals (Sweden)

    Szõcs Attila

    2014-07-01

    Full Text Available Our objective is to provide a framework for measuring brand equity, that is, the added value to the product endowed by the brand. Based on a demand and supply model, we propose a structural model that enables testing the structural effect of brand equity (demand side effect on brand value (supply side effect, using Monte Carlo simulation. Our main research question is which of the three brand value measurement methods (price premium, revenue premium and profit premium is more suitable from the perspective of the structural link between brand equity and brand value. Our model is based on recent developments in random coefficients model applications.

  14. Electrode size and boundary condition independent measurement of the effective piezoelectric coefficient of thin films

    Directory of Open Access Journals (Sweden)

    M. Stewart

    2015-02-01

    Full Text Available The determination of the piezoelectric coefficient of thin films using interferometry is hindered by bending contributions. Using finite element analysis (FEA simulations, we show that the Lefki and Dormans approximations using either single or double-beam measurements cannot be used with finite top electrode sizes. We introduce a novel method for characterising piezoelectric thin films which uses a differential measurement over the discontinuity at the electrode edge as an internal reference, thereby eliminating bending contributions. This step height is shown to be electrode size and boundary condition independent. An analytical expression is derived which gives good agreement with FEA predictions of the step height.

  15. A Tale of two Cities: Photoacoustic and Aethalometer Measurements Comparisons of Light Absorption in Mexico City and Las Vegas, NV, USA

    Science.gov (United States)

    Paredes-Miranda, G.; Arnott, W. P.; Marley, N. A.; Gaffney, J. S.

    2007-05-01

    As part of the Megacity Impacts on Regional and Global Environments, MIRAGE-Mex deployment to Mexico City in the period of 30 days, March 2006, a suite of photoacoustic spectrometers (PAS; W. Arnott & G. Paredes), nephelometer scattering, and aetholemeter absorption instruments (N. Marley & J.Gaffney) were installed to measure at ground level the light absorption and scattering by aerosols at the urban site at Instituto Mexicano del Petroleo (Mexican Oil Institute, denoted by IMP). This IMP site gave in-situ characterization of the Mexico City plume under favorable wind conditions. The PAS used at IMP operates at 532 nm, and conveniently allowed for characterization of gaseous absorption at this wavelength as well. Light scattering measurements are accomplished within the PAS by the reciprocal nephelometery method. In the urban site the aerosol absorption coefficient typically varies between 20 and 180 Mm-1 during the course of the day and significant diurnal variation of the aerosol single scattering albedo was observed. The Las Vegas, NV site was located at East Charleston Street on January-February, 2003. In east Las Vegas typical westerly winds carry the city plume across the site. Comparisons of PAS aerosol light absorption and aetholemeter absorption measurements at 521 nm at both Las Vegas NV and Mexico City sites will be presented. We will also present a broad overview of the diurnal variation of the scattering and absorption as well as the single scattering albedo and fraction of absorption due to gases at the sites in relation to secondary aerosol formation.

  16. Vertical comb drive actuator for the measurement of piezoelectric coefficients in small-scale systems

    International Nuclear Information System (INIS)

    Wooldridge, J; Muniz-Piniella, A; Stewart, M; Shean, T A V; Weaver, P M; Cain, M G

    2013-01-01

    A micro-electro-mechanical systems (MEMS) vertical levitation comb drive actuator has been created for the measurement of piezoelectric coefficients in thin/thick films or piezoelectrically active micro-scale components of other MEMS devices. The device exerts a dynamic force of 33 μN at an applied voltage of 100 V. The charge developed on the piezoelectric test device is measured using a charge sensitive pre-amplifier and lock-in technique, enabling measurements down to 1×10 −5 pC. The system was tested with ten different piezoelectric samples with coefficients in the range 70–1375 pC N −1 and showed a good correlation (r = 0.9997) to measurements performed with macroscopic applied stresses, and piezoelectric impedance resonance techniques. The measurement of the direct piezoelectric effect in micro- and nano-scale piezo-materials has been made possible using MEMS processing technology. This new application of a MEMS metrology device has been developed and fully characterized in order to accurately evaluate the functional properties of piezoelectric materials at the scale required in micro- to nano-scale applications. (paper)

  17. Measurements of linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene in the ν4+ν5 combination band using a cw quantum cascade laser

    KAUST Repository

    Sajid, Muhammad Bilal

    2014-11-01

    Linestrengths, N2-, Ar-, He- and self-broadening coefficients of acetylene have been measured at 296K in the P branch of the ν4+ν5 combination band for 25 rotational transitions. The effect of gas temperature is studied over 296-683K for five transitions to allow the determination of the temperature dependent exponent n for N2- and Ar-broadening coefficients. These measurements were performed using a continuous-wave quantum cascade laser (cw-QCL) operating over 1253-1310cm-1. Spectroscopic parameters were obtained by fitting absorption spectra using Voigt, Galatry and Rautian profiles. Linestrength and broadening results are compared with previous studies available in literature for the ν4+ν5 combination band and other vibrational bands of acetylene. © 2014 Elsevier Ltd.

  18. Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion

    International Nuclear Information System (INIS)

    Kwee, T.C.; Takahara, Taro; Nievelstein, R.A.J.; Mali, W.P.T.M.; Luijten, P.R.; Muro, Isao; Imai, Yutaka; Cauteren, M. Van

    2010-01-01

    The aim of this study was to examine the effect of simulated linear respiratory motion on apparent diffusion coefficient (ADC) measurements. Six rectangular test tubes (14 x 92 mm) filled with either water, tomato ketchup, or mayonnaise were positioned in a box containing agarose gel. This box was connected to a double-acting pneumatic cylinder, capable of inducing periodic linear motion in the long-axis direction of the magnetic bore (23-mm stroke). Diffusion-weighted magnetic resonance imaging was performed for both the static and moving phantoms, and ADC measurements were made in the six test tubes in both situations. In the three test tubes whose long axes were parallel to the direction of motion, ADCs agreed well between the moving and static phantom situations. However, in two test tubes that were filled with fluids that had a considerably lower diffusion coefficient than the surrounding agarose gel, and whose long axes were perpendicular to the direction of motion, the ADCs agreed poorly between the moving and static phantom situations. ADC measurements of large homogeneous structures are not affected by linear respiratory motion. However, ADC measurements of inhomogeneous or small structures are affected by linear respiratory motion due to partial volume effects. (author)

  19. Measurements of elliptic flow and higher-order Fourier coefficients with the ATLAS experiment

    CERN Document Server

    Jia, J; The ATLAS collaboration

    2011-01-01

    We report the measurements of collective harmonic flow coefficients $v_n$ for $n=2-6$ in Pb+Pb collisions at sqrt(s_NN)=2.76 TeV with the ATLAS detector. They are extracted via an event plane method based on the ATLAS Forward Calorimeter over a broad range in $p_T$, $eta$ and centrality. The $v_n$ coefficients are found to change weakly within $|eta|<2.5$ and all with the same qualitative trend as a function of $p_T$: all rise up to 3-4 GeV, and then fall towards higher $p_T$. The high statistical precision of the $v_2$ term, allow us to clearly determine its trend out to 20 GeV for a broad centrality classes. The same harmonic flow coefficients are also obtained via a Fourier analysis of the two-particle $Deltaphi-Deltaeta$ correlation with a large $Deltaeta$ gap. A detailed comparison with the event plane method allow us to determine the regions of the two-particle phase space (in $p_T$ and $Deltaeta$ and centrality), in which the collective phenomena play a dominating role. The physics implications ...

  20. Converting Sabine absorption coefficients to random incidence absorption coefficients

    DEFF Research Database (Denmark)

    Jeong, Cheol-Ho

    2013-01-01

    are suggested: An optimization method for the surface impedances for locally reacting absorbers, the flow resistivity for extendedly reacting absorbers, and the flow resistance for fabrics. With four porous type absorbers, the conversion methods are validated. For absorbers backed by a rigid wall, the surface...... impedance optimization produces the best results, while the flow resistivity optimization also yields reasonable results. The flow resistivity and flow resistance optimization for extendedly reacting absorbers are also found to be successful. However, the theoretical conversion factors based on Miki's model...

  1. Measurement of thermal accommodation coefficients of inert gas mixtures on a surface of stainless steel

    Science.gov (United States)

    Jun, Byung Soon

    Heat transfer in the fuel-clad gap in a nuclear reactor impacts the overall temperature distribution, stored energy and the mechanical properties of a nuclear fuel rod. Therefore, an accurate estimation of the gap conductance between the UO2 fuel and the clad is critically important for reactor design and operations. To obtain the requisite accuracy in the gap conductance estimation, the thermal accommodation coefficients of the various gases present on the fuel outer surface and the cladding inner surface are very important. In present work, we studied the stainless steel that is the most favored cladding material for advanced gas-cooled reactors. Our goal was to obtain the thermal accommodation coefficients of select inert gases and mixtures of the same on this stainless steel. It has been found for pure helium, pure argon and select He-Ar mixtures that the thermal accommodation coefficient values with stainless steel are very close to constant over the range of pressures studied. The values obtained in this work are in good agreement with similar values reported previously in the literature. As far as we aware, these measurements are the first made of the thermal accommodation coefficients of inert gas mixtures on stainless steel. To aid in the verification of the kinetic theory, additional experiments were done using a two-sphere system and were analyzed using the equivalent sphere approximation. It is found that this theory can be applicable to spherical geometry problems and can be used for a wide range of values of the Knudsen number (Kn). Some sensitivity studies were performed to delineate some key parameter effect in terms of cooling rate, DeltaT difference, and Knudsen number.

  2. Using measured octanol-air partition coefficients to explain environmental partitioning of organochlorine pesticides.

    Science.gov (United States)

    Shoeib, Mahiba; Harner, Tom

    2002-05-01

    Octanol-air partition coefficients (Koa) were measured directly for 19 organochlorine (OC) pesticides over the temperature range of 5 to 35 degrees C. Values of log Koa at 25 degrees C ranged over three orders of magnitude, from 7.4 for hexachlorobenzene to 10.1 for 1,1-dichloro-2,2-bis(p-chlorophenyl) ethane. Measured values were compared to values calculated as KowRT/H (where R is the ideal gas constant [8.314 J mol(-1) K(-1)], T is absolute temperature, and H is Henry's law constant) were, in general, larger. Discrepancies of up to three orders of magnitude were observed, highlighting the need for direct measurements of Koa. Plots of Koa versus inverse absolute temperature exhibited a log-linear correlation. Enthalpies of phase transition between octanol and air (deltaHoa) were determined from the temperature slopes and were in the range of 56 to 105 kJ mol(-1) K(-1). Activity coefficients in octanol (gamma(o)) were determined from Koa and reported supercooled liquid vapor pressures (pL(o)), and these were in the range of 0.3 to 12, indicating near-ideal solution behavior. Differences in Koa values for structural isomers of hexachlorocyclohexane were also explored. A Koa-based model was described for predicting the partitioning of OC pesticides to aerosols and used to calculate particulate fractions at 25 and -10 degrees C. The model also agreed well with experimental results for several OC pesticides that were equilibrated with urban aerosols in the laboratory. A log-log regression of the particle-gas partition coefficient versus Koa had a slope near unity, indicating that octanol is a good surrogate for the aerosol organic matter.

  3. Relative measurement of the excitation rate coefficients of the FeXI ion

    International Nuclear Information System (INIS)

    Marotta, A.

    1982-01-01

    The collision rate coefficients for the iron atoms are measured through the hot plasma obtainment. The physical model used in this determination is the crown stationary model which consider that the excitation by electronic collisions is balanced by the spontaneous emission. This work was realized in a 15Kj theta pinch device, of high pulse reproductibility. The iron-pentacarbonyl [Fe(Co) 5 ] was used as the impurity source of a hydrogen gas. The temperature and density were determined by the scattering light analysis of a rubi laser using the Thomson scattering. (L.C.) [pt

  4. Coefficient of Friction Measurements for Thermoplastics and Fiber Composites under Low Sliding Velocity and High Pressure

    DEFF Research Database (Denmark)

    Poulios, Konstantinos; Svendsen, G.; Hiller, Jochen

    2012-01-01

    materials which are untypical for brake applications, like thermoplastics and fiber composites, can offer superior performance in terms of braking torque, wear resistance and cost than typical brake linings. In this paper coefficient of friction measurements for various thermoplastic and fiber composite......Friction materials for typical brake applications are normally designed considering thermal stability as the major performance criterion. There are however brake applications with very limited sliding velocities, where the generated heat is insignificant. In such cases it is possible that friction...

  5. Coefficient of Friction Measurements for Thermoplastics and Fibre Composites Under Low Sliding Velocity and High Pressure

    DEFF Research Database (Denmark)

    Poulios, Konstantinos; Svendsen, Gustav Winther; Hiller, Jochen

    2013-01-01

    that friction materials which are untypical for brake applications, like thermoplastics and fibre composites, can offer superior performance in terms of braking torque, wear resistance and cost than typical brake linings. In this paper coefficient of friction measurements for various thermoplastic and fibre......Friction materials for typical brake applications are normally designed considering thermal stability as the major performance criterion. There are, however, brake applications with very limited sliding velocities, where the generated heat is insignificant. In such cases it is possible...... in order to interpret the changes of friction observed during the running-in phase....

  6. Infrared and UV-visible absorption measurement at Syowa Station (abstract)

    OpenAIRE

    Murata,Isao; Kita,Kazuyuki; Iwagami,Naomoto; Ogawa ,Toshihiro

    1993-01-01

    Vertical column contents of some trace gases were observed by solar infrared and UV-visible absorption techniques at Syowa Station, to study the dynamics and chemistry of Antarctic ozone. HCl, HF, N_2O, OCS, CO and C_2H_6 column contents were measured by infrared absorption spectroscopy in the 3-5

  7. Measurement of isothermal temperature reactivity coefficient at research reactor with IRT-4M fuel

    International Nuclear Information System (INIS)

    Bily, Tomas; Sklenka, Lubomir

    2014-01-01

    Highlights: • Isothermal coefficient of reactivity with IRT-4M fuel was measured. • Experiment was performed at VR-1 zero power reactor. • Tailor-made instrumentation was used. • MCNP code was used for analysis of experimental data. - Abstract: Transients analyses is of high importance for reactor safety studies. The temperature reactivity coefficients belong to key input parameters for such studies. However, the amount of experimental data for validation of such parameters for the conditions of research reactors operated with LEU fuel is limited. To improve the situation, a tailor-made experimental instrumentation has been recently developed at zero power research reactor VR-1 that allows for detailed measurement of temperature reactivity effects in lattices with IRT-4M fuel. The instrumentation enables by external water heater to change the temperature of fuel and surrounding water moderator in 2 × 2 positions of reactor grid in the range from 20 to 40 °C. Using the instrumentation the isothermal temperature reactivity effect was measured for a group of four eight-tube fuel assemblies in the above mentioned temperature range. Results were compared to MCNP calculations with the precise model of the VR-1 reactor. The MCNP code was further used for deeper analysis of experimental data

  8. A Noncontact Measurement Technique for the Density and Thermal Expansion Coefficient of Solid and Liquid Materials

    Science.gov (United States)

    Chung, Sang K.; Thiessen, David B.; Rhim, Won-Kyu

    1996-01-01

    A noncontact measurement technique for the density and the thermal expansion refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator (HTESL) at the Jet Propulsion Laboratory in which 2-3 mm diameter samples can be levitated, melted, and radiatively cooled in a vacuum. Due to the axisymmetric nature of the molten samples when levitated in the HTESL, a rather simple digital image analysis can be employed to accurately measure the volumetric change as a function of temperature. Density and the thermal expansion coefficient measurements were made on a pure nickel sample to test the accuracy of the technique in the temperature range of 1045-1565 C. The result for the liquid phase density can be expressed by p = 8.848 + (6.730 x 10(exp -4)) x T (degC) g/cu cm within 0.8% accuracy, and the corresponding thermal expansion coefficient can be expressed by Beta=(9.419 x 10(exp -5)) - (7.165 x 10(exp -9) x T (degC)/K within 0.2% accuracy.

  9. Heat Transmission Coefficient Measurements in Buildings Utilizing a Heat Loss Measuring Device

    DEFF Research Database (Denmark)

    Sørensen, Lars Schiøtt

    2013-01-01

    and cooling our houses. There is a huge energy-saving potential in this area for reducing both the global climate problems as well as economy challenges. Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from...... to optimize the energy performance. This paper presents a method for measuring the heat loss by utilizing a U-value meter. The U-value meter measures the heat transfer in the unit W/Km2 and has been used in several projects to upgrade the energy performance in temperate regions. The U-value meter was also......Global energy efficiency can be obtained in two ordinary ways. One way is to improve the energy production and supply side, and the other way is, in general, to reduce the consumption of energy in society. This paper has focus on the latter and especially the consumption of energy for heating...

  10. Photothermal method for absorption measurements in anisotropic crystals

    Czech Academy of Sciences Publication Activity Database

    Stubenvoll, M.; Schäfer, B.; Mann, K.; Novák, Ondřej

    2016-01-01

    Roč. 87, č. 2 (2016), 1-7, č. článku 023904. ISSN 0034-6748 R&D Projects: GA ČR GA16-12960S; GA MŠk EE2.3.30.0057 Grant - others:HILASE(XE) CZ.1.05/2.1.00/01.0027; HILASE(XE) CZ.1.05/2.1.00/01.0027; OP VK 4 POSTDOK(XE) CZ.1.07/2.3.00/30.0057 Institutional support: RVO:68378271 Keywords : wave-front deformation * bulk absorption * gray-tracking * barium borate * duv-optics * ktp Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.515, year: 2016

  11. A new method for measuring the interdiffusion coefficient in a liquid metal alloy

    International Nuclear Information System (INIS)

    Gonella, Ch.; Blanchet, A.; Le Ny, J.

    2000-01-01

    A knowledge of diffusion mechanisms and the values of associated coefficients is essential for controlling changes in heated materials and alloys with time. In contrast to solids, where a large literature is available, little research has been done on diffusion coefficients in liquid metals. This is due to experimental difficulties: compatibility of the liquid with the measurement cell, high vapor pressures, convective processes. A significant improvement was achieved by the use of the shear cell, which puts the elements into contact with each other at the selected working temperature and isolates the different sections at the end of the diffusion time. This method employs radioactive sources, generally as tracers, which need counting after cooling. Each alloy composition requires a test, increasing the number of experiments needed. To eliminate the use of tracers, we propose a method based on the shear cell procedure for putting the liquids into contact, which allows determination of the interdiffusion coefficient in a liquid alloy in a single experiment from the measurement of a mass spectrometer signal. The experimental principle is shown schematically. Iron is in the upper ceramic cell and uranium in the lower. After stabilizing the temperature and adjusting the detected signal of the spectrometer to the mass of iron, the iron and uranium are brought into contact by rotating the upper cell from outside the vacuum chamber. The diffusion experiment consists in recording the decrease over time of the signal received by the spectrometer. During the diffusion period, the upper surface of the iron is enriched in uranium, thereby decreasing the thermodynamic activity of the iron and the detected signal. (authors)

  12. Radionuclide adsorption distribution coefficients measured in Hanford sediments for the low level waste performance assessment project

    International Nuclear Information System (INIS)

    Kaplan, D.I.; Serne, R.J.; Owen, A.T.

    1996-08-01

    Preliminary modeling efforts for the Hanford Site's Low Level Waste-Performance Assessment (LLW PA) identified 129 I, 237 Np, 79 Se, 99 Tc, and 234 , 235 , 238 U as posing the greatest potential health hazard. It was also determined that the outcome of these simulations was very sensitive to the parameter describing the extent to which radionuclides sorb to the subsurface matrix, i.e., the distribution coefficient (K d ). The distribution coefficient is a ratio of the radionuclide concentration associated with the solid phase to that in the liquid phase. The objectives of this study were to (1) measure iodine, neptunium, technetium, and uranium K d values using laboratory conditions similar to those expected at the LLW PA disposal site, and (2) evaluate the effect of selected environmental parameters, such as pH, ionic strength, moisture concentration, and radio nuclide concentration, on K d values of selected radionuclides. It is the intent of these studies to develop technically defensible K d values for the PA. The approach taken throughout these studies was to measure the key radio nuclide K d values as a function of several environmental parameters likely to affect their values. Such an approach provides technical defensibility by identifying the mechanisms responsible for trends in K d values. Additionally, such studies provide valuable guidance regarding the range of K d values likely to be encountered in the proposed disposal site

  13. Tire-to-Surface Friction-Coefficient Measurements with a C-123B Airplane on Various Runway Surfaces

    Science.gov (United States)

    Sawyer, Richard H.; Kolnick, Joseph J.

    1959-01-01

    An investigation was conducted to obtain information on the tire-to-surface friction coefficients available in aircraft braking during the landing run. The tests were made with a C-123B airplane on both wet and dry concrete and bituminous pavements and on snow-covered and ice surfaces at speeds from 12 to 115 knots. Measurements were made of the maximum (incipient skidding) friction coefficient, the full-skidding (locked wheel) friction coefficient, and the wheel slip ratio during braking.

  14. Comparison of two dependent within subject coefficients of variation to evaluate the reproducibility of measurement devices

    Directory of Open Access Journals (Sweden)

    Kaya Namik

    2008-04-01

    Full Text Available Abstract Background The within-subject coefficient of variation and intra-class correlation coefficient are commonly used to assess the reliability or reproducibility of interval-scale measurements. Comparison of reproducibility or reliability of measurement devices or methods on the same set of subjects comes down to comparison of dependent reliability or reproducibility parameters. Methods In this paper, we develop several procedures for testing the equality of two dependent within-subject coefficients of variation computed from the same sample of subjects, which is, to the best of our knowledge, has not yet been dealt with in the statistical literature. The Wald test, the likelihood ratio, and the score tests are developed. A simple regression procedure based on results due to Pitman and Morgan is constructed. Furthermore we evaluate the statistical properties of these methods via extensive Monte Carlo simulations. The methodologies are illustrated on two data sets; the first are the microarray gene expressions measured by two plat- forms; the Affymetrix and the Amersham. Because microarray experiments produce expressions for a large number of genes, one would expect that the statistical tests to be asymptotically equivalent. To explore the behaviour of the tests in small or moderate sample sizes, we illustrated the methodologies on data from computer-aided tomographic scans of 50 patients. Results It is shown that the relatively simple Wald's test (WT is as powerful as the likelihood ratio test (LRT and that both have consistently greater power than the score test. The regression test holds its empirical levels, and in some occasions is as powerful as the WT and the LRT. Conclusion A comparison between the reproducibility of two measuring instruments using the same set of subjects leads naturally to a comparison of two correlated indices. The presented methodology overcomes the difficulty noted by data analysts that dependence between

  15. Measurement of secondary cosmic radiation and calculation of associated dose conversion coefficients for humans

    International Nuclear Information System (INIS)

    Simmer, Gregor

    2012-01-01

    Due to secondary cosmic radiation (SCR), pilots and flight attendants receive elevated effective doses at flight altitudes. For this reason, since 2003 aircrew members are considered as occupationally exposed, in Germany. This work deals with the calculation of dose conversion coefficients (DCC) for protons, neutrons, electrons, positrons, photons and myons, which are crucial for estimation of effective dose from SCR. For the first time, calculations were performed combining Geant4 - a Monte Carlo code developed at CERN - with the voxel phantoms for the reference female and male published in 2008 by ICRP and ICRU. Furthermore, measurements of neutron fluence spectra - which contribute the major part to the effective dose of SCR - were carried out at the Environmental Research Station Schneefernerhaus (UFS) located at 2650 m above sea level nearby the Zugspitze mountain, Germany. These measured neutron spectra, and additionally available calculated spectra, were then folded with the DCC calculated in this work, and effective dose rates for different heights were calculated.

  16. Codon Deviation Coefficient: A novel measure for estimating codon usage bias and its statistical significance

    KAUST Repository

    Zhang, Zhang

    2012-03-22

    Background: Genetic mutation, selective pressure for translational efficiency and accuracy, level of gene expression, and protein function through natural selection are all believed to lead to codon usage bias (CUB). Therefore, informative measurement of CUB is of fundamental importance to making inferences regarding gene function and genome evolution. However, extant measures of CUB have not fully accounted for the quantitative effect of background nucleotide composition and have not statistically evaluated the significance of CUB in sequence analysis.Results: Here we propose a novel measure--Codon Deviation Coefficient (CDC)--that provides an informative measurement of CUB and its statistical significance without requiring any prior knowledge. Unlike previous measures, CDC estimates CUB by accounting for background nucleotide compositions tailored to codon positions and adopts the bootstrapping to assess the statistical significance of CUB for any given sequence. We evaluate CDC by examining its effectiveness on simulated sequences and empirical data and show that CDC outperforms extant measures by achieving a more informative estimation of CUB and its statistical significance.Conclusions: As validated by both simulated and empirical data, CDC provides a highly informative quantification of CUB and its statistical significance, useful for determining comparative magnitudes and patterns of biased codon usage for genes or genomes with diverse sequence compositions. 2012 Zhang et al; licensee BioMed Central Ltd.

  17. [The measurement of thermal expansion coefficient of Co-Cr alloy fabricated by selective laser melting].

    Science.gov (United States)

    Tian, Xiao-mei; Zeng, Li; Wei, Bin; Huang, Yi-feng

    2015-12-01

    To investigate the thermal expansion coefficient of different processing parameters upon the Co-Cr alloy prepared by selective laser melting (SLM) technique, in order to provide technical support for clinical application of SLM technology. The heating curve of self-made Co-Cr alloy was protracted from room temperature to 980°C centigrade with DIL402PC thermal analysis instrument, keeping temperature rise rate and cooling rate at 5 K/min, and then the thermal expansion coefficient of 9 groups of Co-Cr alloy was measured from 20°C centigrade to 500°C centigrade and 600°C centigrade. The 9 groups thermal expansion coefficient values of Co-Cr alloy heated from 20°C centigrade to 500°C centigrade were 13.9×10(-6)/K,13.6×10(-6)/K,13.9×10(-6)/K,13.7×10(-6)/K,13.5×10(-6)/K,13.8×10(-6)/K,13.7×10(-6)/K,13.7×10(-6)/K,and 13.9×10(-6)/K, respectively; when heated from 20°C centigrade to 600°C centigrade, they were 14.2×10(-6)/K,13.9×10(-6)/K,13.8×10(-6)/K,14.0×10(-6)/K,14.1×10(-6)/K,14.1×10(-6)/K,13.9×10(-6)/K,14.2×10(-6)/K, and 13.7×10(-6)/K, respectively. The results showed that the Co-Cr alloy has good matching with the VITA VMK 95 porcelain powder and can meet the requirement of clinic use.

  18. Absorption of Solar Radiation by the Cloudy Atmosphere Interpretations of Collocated Aircraft Measurements

    Science.gov (United States)

    Valero, Francisco P. J.; Cess, Robert D.; Zhang, Minghua; Pope, Shelly K.; Bucholtz, Anthony; Bush, Brett; Vitko, John, Jr.

    1997-01-01

    As part of the Atmospheric Radiation Measurement (ARM) Enhanced Shortwave Experiment (ARESE), we have obtained and analyzed measurements made from collocated aircraft of the absorption of solar radiation within the atmospheric column between the two aircraft. The measurements were taken during October 1995 at the ARM site in Oklahoma. Relative to a theoretical radiative transfer model, we find no evidence for excess solar absorption in the clear atmosphere and significant evidence for its existence in the cloudy atmosphere. This excess cloud solar absorption appears to occur in both visible (0.224-0.68 microns) and near-infrared (0.68-3.30 microns) spectral regions, although not at 0.5 microns for the visible contribution, and it is shown to be true absorption rather than an artifact of sampling errors caused by measuring three-dimensional clouds.

  19. Measurement of atmospheric precipitable water using a solar radiometer. [water vapor absorption effects

    Science.gov (United States)

    Pitts, D. E.; Dillinger, A. E.; Mcallum, W. E.

    1974-01-01

    A technique is described and tested that allows the determination of atmospheric precipitable water from two measurements of solar intensity: one in a water-vapor absorption band and another in a nearby spectral region unaffected by water vapor.

  20. A Compact In Situ Sensor for Measurement of Absorption and Backscattering in Natural Waters, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop an active sensor for in situ measurement of the inherent optical properties (IOPs) absorption and backscattering at multiple wavelengths....

  1. Measurement of the effective atomic numbers of compounds with cerium near to the absorption edge

    International Nuclear Information System (INIS)

    Polat, Recep; Icelli, Orhan

    2010-01-01

    In order to measure atomic, molecular and electronic cross-section; the effective atomic number, density of electron and absorption jump factor, we have first measured μ t values of compounds which are determined by mixture rule using transmission method. In order to measure experimentally the effective atomic number within absorption jump factors of compounds with Ce, the X-ray source used Am-241 whose gamma rays were stopped at secondary source (Sm), thus producing Kα and Kβ X-ray emission. The most crucial finding in this study is that measurement of the effective atomic number is not appropriate near to the absorption edge and the effective atomic number is affected by near to the absorption edge. The results obtained have been compared with theoretical values.

  2. Measurement of the first Townsend ionization coefficient in a methane-based tissue-equivalent gas

    Energy Technology Data Exchange (ETDEWEB)

    Petri, A.R. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Gonçalves, J.A.C. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Departamento de Física, Pontifícia Universidade Católica de São Paulo, 01303-050 São Paulo (Brazil); Mangiarotti, A. [Instituto de Física - Universidade de São Paulo, Cidade Universitária, 05508-080 São Paulo (Brazil); Botelho, S. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Bueno, C.C., E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil)

    2017-03-21

    Tissue-equivalent gases (TEGs), often made of a hydrocarbon, nitrogen, and carbon dioxide, have been employed in microdosimetry for decades. However, data on the first Townsend ionization coefficient (α) in such mixtures are scarce, regardless of the chosen hydrocarbon. In this context, measurements of α in a methane-based tissue-equivalent gas (CH{sub 4} – 64.4%, CO{sub 2} – 32.4%, and N{sub 2} – 3.2%) were performed in a uniform field configuration for density-normalized electric fields (E/N) up to 290 Td. The setup adopted in our previous works was improved for operating at low pressures. The modifications introduced in the apparatus and the experimental technique were validated by comparing our results of the first Townsend ionization coefficient in nitrogen, carbon dioxide, and methane with those from the literature and Magboltz simulations. The behavior of α in the methane-based TEG was consistent with that observed for pure methane. All the experimental results are included in tabular form in the .

  3. An easy way to measure accurately the direct magnetoelectric voltage coefficient of thin film devices

    Science.gov (United States)

    Poullain, Gilles; More-Chevalier, Joris; Cibert, Christophe; Bouregba, Rachid

    2017-01-01

    TbxDy1-xFe2/Pt/Pb(Zrx, Ti1-x)O3 thin films were grown on Pt/TiO2/SiO2/Si substrate by multi-target sputtering. The magnetoelectric voltage coefficient αΗΜΕ was determined at room temperature using a lock-in amplifier. By adding, in series in the circuit, a capacitor of the same value as that of the device under test, we were able to demonstrate that the magnetoelectric device behaves as a voltage source. Furthermore, a simple way to subtract the stray voltage arising from the flow of eddy currents in the measurement set-up, is proposed. This allows the easy and accurate determination of the true magnetoelectric voltage coefficient. A large αΗΜΕ of 8.3 V/cm. Oe was thus obtained for a Terfenol-D/Pt/PZT thin film device, without DC magnetic field nor mechanical resonance.

  4. Measurement of Retinalamin diffusion coefficient in human sclera by optical spectroscopy

    Science.gov (United States)

    Genina, Elina A.; Bashkatov, Alexey N.; Zubkova, Elena A.; Kamenskikh, Tatiana G.; Tuchin, Valery V.

    2008-12-01

    The use of cytomedines (such as Retinalamin) in clinical practice has shown high effectiveness of the medicaments in ophthalmology. The study of diffusion of Retinalamin in scleral tissue is important for estimation of a drug dose delivered into inner tissue of eye, time of drug action, etc. In vitro measurements of spectral reflectance of sclera interacting with aqueous solution of Retinalamin have been carried out. Ten human sclera samples were included in the study. The results of the experiments have shown that penetration of Retinalamin into scleral tissue leads to the decrease of scleral reflectance due to optical immersion. Estimation of diffusion coefficient of studied solution has been made on the basis of analysis of optical reflectance dynamics of the sclera samples. The diffusion coefficient of Retinalamin in human scleral tissue was evaluated as (1.82±0.14)×10 -6 cm 2/s. The results are important for treatment of partial optic atrophy observed at primary open-angle glaucoma and others eye diseases.

  5. Measuring the flexoelectric coefficient of bulk barium titanate from a shock wave experiment

    Science.gov (United States)

    Hu, Taotao; Deng, Qian; Liang, Xu; Shen, Shengping

    2017-08-01

    In this paper, a phenomenon of polarization introduced by shock waves is experimentally studied. Although this phenomenon has been reported previously in the community of physics, this is the first time to link it to flexoelectricity, the coupling between electric polarization and strain gradients in dielectrics. As the shock waves propagate in a dielectric material, electric polarization is thought to be induced by the strain gradient at the shock front. First, we control the first-order hydrogen gas gun to impact and generate shock waves in unpolarized bulk barium titanate (BT) samples. Then, a high-precision oscilloscope is used to measure the voltage generated by the flexoelectric effect. Based on experimental results, strain elastic wave theory, and flexoelectric theory, a longitudinal flexoelectric coefficient of the bulk BT sample is calculated to be μ 11 = 17.33 × 10 - 6 C/m, which is in accord with the published transverse flexoelectric coefficient. This method effectively suppresses the majority of drawbacks in the quasi-static and low frequency dynamic techniques and provides more reliable results of flexoelectric behaviors.

  6. Critical electrode size in measurement of d33 coefficient of films via spatial distribution of piezoelectric displacement

    International Nuclear Information System (INIS)

    Wang Zhihong; Miao Jianmin

    2008-01-01

    Spatial distributions of piezoelectric displacement response across the top electrode have been used in this paper to measure the piezoelectric coefficient d 33 of films based on the converse piezoelectric effect. The technical details and features of a scanning laser Doppler vibrometer have been summarized and discussed for accurately obtaining the spatial displacement distributions. Three definitions, including the apparent, the effective and the constrained piezoelectric coefficient d 33 of films, have been clarified and used to better understand the fundamental phenomenon behind the measured displacement distributions. Finite element analysis reveals that both the apparent and the effective piezoelectric coefficients depend on the electrode radius of test capacitor as well as film thickness. However, there exists a critical electrode size for apparent piezoelectric coefficients and a critical test capacitor aspect ratio for effective piezoelectric coefficient. Beyond their respective critical values, both coefficients converge to the constrained piezoelectric coefficient irrespective of film thickness. The finding of the critical electric size makes it possible to consistently measure the constrained piezoelectric coefficient of films by using the spatial distributions of the piezoelectric displacement response and becomes the fundamental criterion of this measurement method

  7. Measurement of attenuation coefficient of core and cladding modes in Bragg fiber

    Science.gov (United States)

    Frank, Milan; Jelínek, Michal; Kubeček, Václav; Matějec, Vlastimil; Podrazký, Ondřej; Kašík, Ivan

    2017-12-01

    In this contribution a new method for determination of transmission characteristics and mechanism of optical radiation propagation in Bragg fibers is described. The investigated Bragg fibers are designed for high-power laser radiation delivery. Attenuation coefficient and coupling efficiency are usually measured using simple cutback method for optimum mode matching of the incident radiation to the fiber mode. Our current approach is based on the cut-back technique but we also investigate the dependence of the mentioned parameters on radial position of the excitation mode from the fiber axis. In addition, using the imaging of the measured fiber output face on a CCD camera, the spatial profile of the propagated beam can be obtained. For this reason this method is suitable for delivered laser mode control. The investigated Bragg fiber consisted of the 26um diameter silica core surrounded by three pairs of circular Bragg layers. Each pair is composed of one layer with a high and one layer with a low refractive index being characterized by a refractive-index contrast up to 0.03. The 1064nm laser beam was focused by a telescope onto the fiber input face. The beam radius in the focal plane was 5um. The Bragg fiber output face was imaged by a 1:6 optical telescope on the CCD camera. The transmitted power and spatial beam profile were registered simultaneously for various offset from the fiber axis. After the fiber shortening, the measurement was repeated and the cut-back was performed. The lowest attenuation coefficient of 0.17dB/m corresponded to a core mode of the delivered laser radiation. In general, the attenuation was higher with a shift from the radial axis of the fiber symmetry. In the case of cladding mode excitation, the attenuation parameter shows a local minimum. This phenomenon was consistent with the refractive index profile of the tested Bragg fiber.

  8. Intersubband optical absorption coefficients and refractive index changes in a graded quantum well under intense laser field: Effects of hydrostatic pressure, temperature and electric field

    International Nuclear Information System (INIS)

    Ungan, F.; Restrepo, R.L.; Mora-Ramos, M.E.; Morales, A.L.; Duque, C.A.

    2014-01-01

    The effects of hydrostatic pressure, temperature, and electric field on the optical absorption coefficients and refractive index changes associated with intersubband transition in a typical GaAs/Ga 0.7 Al 0.3 As graded quantum well under intense laser field have been investigated theoretically. The electron energy eigenvalues and the corresponding eigenfunctions of the graded quantum well are calculated within the effective mass approximation and envelope wave function approach. The analytical expressions of the optical properties are obtained using the compact density-matrix approach and the iterative method. The numerical results show that the linear and nonlinear optical properties depend strongly on the intense laser field and electric field but weakly on the hydrostatic pressure and temperature. Additionally, it has been found that the electronic and optical properties in a GaAs/Ga 0.7 Al 0.3 As graded quantum well under the intense laser field can be tuned by changing these external inputs. Thus, these results give a new degree of freedom in the devices applications

  9. Intestinal cholesterol transport: Measuring cholesterol absorption and its reverse

    NARCIS (Netherlands)

    Jakulj, L.

    2013-01-01

    Intestinal cholesterol transport might serve as an attractive future target for cardiovascular disease reduction, provided that underlying molecular mechanisms are more extensively elucidated, combined with improved techniques to measure changes in cholesterol fluxes and their possible

  10. Apparent Diffusion Coefficient Measurement in Mediastinal Lymphadenopathies: Differentiation between Benign and Malignant Lesions

    Directory of Open Access Journals (Sweden)

    Fethi Emre Ustabasioglu

    2017-01-01

    Full Text Available Objectives: We aimed to prospectively assess the diagnostic value of apparent diffusion coefficient (ADC measurement in the differentiation of benign and malignant mediastinal lymphadenopathies. Materials and Methods: The study included 63 consecutive patients (28 women, 35 men; mean age 59.3 years with 125 mediastinal lymphadenopathies. Echoplanar diffusion-weighted magnetic resonance imaging of the mediastinum was performed with b-factors of 0 and 600 mm2/s before mediastinoscopy and mediastinotomy, and ADC values were measured. The ADC values were compared with the histological results, and statistical analysis was done. P < 0.05 was considered statistically significant. Results: The mean ADC value of malignant mediastinal lymphadenopathy (1.030 ± 0.245 × 10−3 mm2/s was significantly lower (P < 0.05 when compared to benign lymphadenopathies (1.571 ± 0.559 × 10−3 mm2/s. For differentiating malignant from benign mediastinal lymphadenopathy, the best result was obtained when an ADC value of 1.334 × 10−3 mm2/s was used as a threshold value; area under the curve 0.848, accuracy 78.4%, sensitivity 66%, specificity of 86%, positive predictive value 76.7%, and negative predictive value of 79.2%. Interobserver agreement was excellent for ADC measurements. Conclusions: ADC measurements could be considered an important supportive method in differentiating benign from malignant mediastinal lymphadenopathies.

  11. SPME-Based Ca-History Method for Measuring SVOC Diffusion Coefficients in Clothing Material.

    Science.gov (United States)

    Cao, Jianping; Liu, Ningrui; Zhang, Yinping

    2017-08-15

    Clothes play an important role in dermal exposure to indoor semivolatile organic compounds (SVOCs). The diffusion coefficient of SVOCs in clothing material (D m ) is essential for estimating SVOC sorption by clothing material and subsequent dermal exposure to SVOCs. However, few studies have reported the measured D m for clothing materials. In this paper, we present the solid-phase microextraction (SPME) based C a -history method. To the best of our knowledge, this is the first try to measure D m with known relative standard deviation (RSD). A thin sealed chamber is formed by a circular ring and two pieces of flat SVOC source materials that are tightly covered by the targeted clothing materials. D m is obtained by applying an SVOC mass transfer model in the chamber to the history of gas-phase SVOC concentrations (C a ) in the chamber measured by SPME. D m 's of three SVOCs, di-iso-butyl phthalate (DiBP), di-n-butyl phthalate (DnBP), and tris(1-chloro-2-propyl) phosphate (TCPP), in a cotton T-shirt can be obtained within 16 days, with RSD less than 3%. This study should prove useful for measuring SVOC D m in various sink materials. Further studies are expected to facilitate application of this method and investigate the effects of temperature, relative humidity, and clothing material on D m .

  12. Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.

    Science.gov (United States)

    Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L

    2014-03-01

    Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.

  13. Measurements of the hydrogenic recombination coefficient for the TFTR vacuum vessel

    International Nuclear Information System (INIS)

    Dylla, H.F.; Cecchi, J.L.; Knize, R.J.

    1983-12-01

    Characteristic values of the recombination rate coefficient for hydrogen and deuterium in stainless steel have been measured for the inner wall of the TFTR vacuum vessel for vessel temperatures of 25 to 100 C. In situ measurements of k/sub r/ are important for predicting the hydrogen isotope retention in the wall as a function of time, temperature, and discharge exposure, particularly because existing laboratory measurements of k/sub r/ for stainless steel span a range of four orders of magnitude. The measurement technique involved the observation of the decrease in hydrogen pressure during a glow discharge in the TFTR vacuum vessel with an initial static gas fill. The resulting values of k/sub r/ at 25 C are in the range of (0.4 to 4) x 10 -27 cm 4 -s -1 assuming a value of the hydrogenic diffusivity of 2 x 10 -12 cm 2 -s -1 at room temperature. No significant isotopic dependence was observed and the temperature dependence of k/sub r/ is consistent with the literature value (0.5 eV) of the activation energy. The implications of this range of values of k/sub r/, for the estimation of the in-vessel tritium inventory following D-T operation in TFTR are discussed

  14. Characterisation of large area THGEMs and experimental measurement of the Townsend coefficients for CF4

    Science.gov (United States)

    Burns, J.; Crane, T.; Ezeribe, A. C.; Grove, C. L.; Lynch, W.; Scarff, A.; Spooner, N. J. C.; Steer, C.

    2017-10-01

    Whilst the performance of small THGEMs is well known, here we consider the challenges in scaling these up to large area charge readouts. We first verify the expected gain of larger THGEMs by reporting experimental Townsend coefficients for a 10 cm diameter THGEM in low-pressure CF4. Large area 50 cm by 50 cm THGEMs were sourced from a commercial PCB supplier and geometrical imperfections were observed which we quantified using an optical camera setup. The large area THGEMs were experimentally characterised at Boulby Underground Laboratory through a series of gain calibrations and alpha spectrum measurements. ANSYS, Magboltz and Garfield++ simulations of the design of a TPC based on the large area THGEMs are presented. We also consider their implications for directional dark matter research and potential applications within nuclear security.

  15. Measuring Apparatus for Convective Heat Transfer Coefficient of Nanofluids Using a Thermistor Temperature Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sin Pyo [Kyonggi Univ., Suwon (Korea, Republic of)

    2016-02-15

    Fine wires made from platinum have been used as sensors to evaluate the convection performance of nanofluids. However, the wire sensor is difficult to handle due to its fragility. Additionally, an unrealistic convective heat transfer coefficient (h) is obtained if a rigorous calibration process combined with precision equipment is not used for measurement. This paper proposes a new evaluation apparatus for h of nanofluids that uses a thermistor sensor instead of the platinum wire. The working principles are also explained in detail. Validation experiments for pure engine oil comparing h from the two sensors confirmed numerous practical benefits of the thermistor. The proposed system can be used as a useful tool to justify the adoption of developed nanofluids.

  16. Measurement of exposure buildup factors: The influence of scattered photons on gamma-ray attenuation coefficients

    Science.gov (United States)

    Mann, Kulwinder Singh

    2018-01-01

    Scattered photon's influence on measured values of attenuation coefficients (μm, cm2g-1) for six low-Z (effective atomic number) building materials, at three photon energies has been estimated. Narrow-beam transmission geometry has been used for the measurements. Samples of commonly used engineering materials (Cements, Clay, Lime-Stone, Plaster of Paris) have been selected for the present study. Standard radioactive sources Cs137 and Co60 have been used for obtaining γ-ray energies 661.66, 1173.24 and 1332.50 keV. The optical thickness (OT) of 0.5 mfp (mean free path) has been found the optimum optical thickness (OOT) for μm-measurement in the selected energy range (661.66-1332.50 keV). The aim of this investigation is to provide neglected information regarding subsistence of scattered photons in narrow beam geometry measurements for low-Z materials. The measurements have been performed for a wide range of sample-thickness (2-26 cm) such that their OT varies between 0.2-3.5 mfp in selected energy range. A computer program (GRIC2-toolkit) has been used for various theoretical computations required in this investigation. It has been concluded that in selected energy-range, good accuracy in μm-measurement of low-Z materials can be achieved by keeping their sample's OT below 0.5 mfp. The exposure buildup factors have been measured with the help of mathematical-model developed in this investigation.

  17. The accurate measurement of second virial coefficients using self-interaction chromatography: experimental considerations.

    Science.gov (United States)

    Quigley, A; Heng, J Y Y; Liddell, J M; Williams, D R

    2013-11-01

    Measurement of B22, the second virial coefficient, is an important technique for describing the solution behaviour of proteins, especially as it relates to precipitation, aggregation and crystallisation phenomena. This paper describes the best practise for calculating B22 values from self-interaction chromatograms (SIC) for aqueous protein solutions. Detailed analysis of SIC peak shapes for lysozyme shows that non-Gaussian peaks are commonly encountered for SIC, with typical peak asymmetries of 10%. This asymmetry reflects a non-linear chromatographic retention process, in this case heterogeneity of the protein-protein interactions. Therefore, it is important to use the centre of mass calculations for determining accurate retention volumes and thus B22 values. Empirical peak maximum chromatogram analysis, often reported in the literature, can result in errors of up to 50% in B22 values. A methodology is reported here for determining both the mean and the variance in B22 from SIC experiments, includes a correction for normal longitudinal peak broadening. The variance in B22 due to chemical effects is quantified statistically and is a measure of the heterogeneity of protein-protein interactions in solution. In the case of lysozyme, a wide range of B22 values are measured which can vary significantly from the average B22 values. Copyright © 2013. Published by Elsevier B.V.

  18. Field Measurements of Water Continuum and Water Dimer Absorption by Active Long Path Differential Optical Absorption Spectroscopy (DOAS)

    OpenAIRE

    Lotter, Andreas

    2006-01-01

    Water vapor plays an important role in Earth's radiative budget since water molecules strongly absorb the incoming solar shortwave and the outgoing thermal infrared radiation. Superimposed on the water monomer absorption, a water continuum absorption has long been recognized, but its true nature still remains controversial. On the one hand, this absorption is explained by a deformation of the line shape of the water monomer absorption lines as a consequence of a molecular collision. One the o...

  19. [Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum].

    Science.gov (United States)

    Liu, Hui-jun; Tao, Shao-hua; Yang, Bing-chu; Deng, Hong-gui

    2015-12-01

    The absorptance spectrum of a gas is the basis for the qualitative and quantitative analysis of the gas by the law of the Lambert-Beer. The integral value of the absorptance spectrum is an important parameter to describe the characteristics of the gas absorption. Based on the measured absorptance spectrum of a gas, we collected the required data from the database of HIT-RAN, and chose one of the spectral lines and calculated the integral value of the absorptance spectrum in the frequency domain, and then substituted the integral value into Lambert-Beer's law to obtain the concentration of the detected gas. By calculating the integral value of the absorptance spectrum we can avoid the more complicated calculation of the spectral line function and a series of standard gases for calibration, so the gas concentration measurement will be simpler and faster. We studied the changing trends of the integral values of the absorptance spectrums versus temperature. Since temperature variation would cause the corresponding variation in pressure, we studied the changing trends of the integral values of the absorptance spectrums versus both the pressure not changed with temperature and changed with the temperature variation. Based on the two cases, we found that the integral values of the absorptance spectrums both would firstly increase, then decrease, and finally stabilize with temperature increasing, but the ranges of specific changing trend were different in the two cases. In the experiments, we found that the relative errors of the integrated values of the absorptance spectrum were much higher than 1% and still increased with temperature when we only considered the change of temperature and completely ignored the pressure affected by the temperature variation, and the relative errors of the integrated values of the absorptance spectrum were almost constant at about only 1% when we considered that the pressure were affected by the temperature variation. As the integral value

  20. Active feedback regulation of a Michelson interferometer to achieve zero-background absorption measurements.

    Science.gov (United States)

    Lundin, Patrik; Guan, Zuguang; Svanberg, Sune

    2011-01-20

    An active phase-controlling scheme based on a proportional-integral-derivative-controlled piezoelectric transducer is presented with the purpose of stabilizing a quasi-zero-background absorption spectrometer. A fiber-based balanced Michelson interferometer is used, and absorption due to a gas sample in one of its arms results in an increased light signal to a detector, which otherwise, thanks to destructive interference, experiences a very low light level. With the presented approach, the sensitivity of already potent absorption measurement techniques, e.g., based on modulation, could be improved even further.

  1. Data for moisture measurements during vertical absorption in building porous materials such as brick and limestone.

    Science.gov (United States)

    Evangelides, Chris; Arampatzis, George

    2018-04-01

    This article contains the datasets obtained from experiments in laboratory related to moisture propagation in building porous materials. The datasets contain moisture measurements and corresponding time measurements during vertical infiltration experiment in brick and limestone samples. Moisture measurements were carried out using a γ-ray device and water volume absorption was recorded by a computer controlled digital scale.

  2. Spectral light absorption by ambient aerosols influenced by biomass burning in the Amazon Basin. I: Comparison and field calibration of absorption measurement techniques

    Directory of Open Access Journals (Sweden)

    O. Schmid

    2006-01-01

    Amazonian aerosol, we found no absorption enhancement due to hygroscopic particle growth in the relative humidity (RH range between 40% and 80%. However, a substantial bias in PSAP sensitivity that correlated with both RH and temperature (T was observed for 20%measurement principle, the PSAP and Aethalometer require markedly different correction factors, which is probably due to the different filter media used. Although on-site calibration of the PSAP and Aethalometer is advisable for best data quality, we recommend a set of "best practice" correction factors for ambient sampling based on the data from the present and previous studies. For this study, the estimated accuracies of the absorption coefficients determined by the PAS, PSAP and Aethalometer were 10, 15 and 20% (95% confidence level, respectively.

  3. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats.

    Science.gov (United States)

    Zilversmit, D B; Hughes, L B

    1974-09-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ((14)C or (3)H) and an intravenous dose of colloidal labeled cholesterol ((3)H or (14)C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-hr period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method.

  4. Optoacoustic measurements of water vapor absorption at selected CO laser wavelengths in the 5-micron region

    Science.gov (United States)

    Menzies, R. T.; Shumate, M. S.

    1976-01-01

    Measurements of water vapor absorption were taken with a resonant optoacoustical detector (cylindrical pyrex detector, two BaF2 windows fitted into end plates at slight tilt to suppress Fabry-Perot resonances), for lack of confidence in existing spectral tabular data for the 5-7 micron region, as line shapes in the wing regions of water vapor lines are difficult to characterize. The measurements are required for air pollution studies using a CO laser, to find the differential absorption at the wavelengths in question due to atmospheric constituents other than water vapor. The design and performance of the optoacoustical detector are presented. Effects of absorption by ambient NO are considered, and the fixed-frequency discretely tunable CO laser is found suitable for monitoring urban NO concentrations in a fairly dry climate, using the water vapor absorption data obtained in the study.

  5. The effect of ISM absorption on stellar activity measurements and its relevance for exoplanet studies

    Science.gov (United States)

    Fossati, L.; Marcelja, S. E.; Staab, D.; Cubillos, P. E.; France, K.; Haswell, C. A.; Ingrassia, S.; Jenkins, J. S.; Koskinen, T.; Lanza, A. F.; Redfield, S.; Youngblood, A.; Pelzmann, G.

    2017-05-01

    Past ultraviolet and optical observations of stars hosting close-in Jupiter-mass planets have shown that some of these stars present an anomalously low chromospheric activity, significantly below the basal level. For the hot Jupiter planet host WASP-13, observations have shown that the apparent lack of activity is possibly caused by absorption from the intervening interstellar medium (ISM). Inspired by this result, we study the effect of ISM absorption on activity measurements (S and log R 'HK indices) for main-sequence late-type stars. To this end, we employ synthetic stellar photospheric spectra combined with varying amounts of chromospheric emission and ISM absorption. We present the effect of ISM absorption on activity measurements by varying several instrumental (spectral resolution), stellar (projected rotational velocity, effective temperature, and chromospheric emission flux), and ISM parameters (relative velocity between stellar and ISM Ca II lines, broadening b-parameter, and Ca II column density). We find that for relative velocities between the stellar and ISM lines smaller than 30-40 km s-1 and for ISM Ca II column densities log NCaII ⪆ 12, the ISM absorption has a significant influence on activity measurements. Direct measurements and three dimensional maps of the Galactic ISM absorption indicate that an ISM Ca II column density of log NCaII = 12 is typically reached by a distance of about 100 pc along most sight lines. In particular, for a Sun-like star lying at a distance greater than 100 pc, we expect a depression (bias) in the log R'HK value larger than 0.05-0.1 dex, about the same size as the typical measurement and calibration uncertainties on this parameter. This work shows that the bias introduced by ISM absorption must always be considered when measuring activity for stars lying beyond 100 pc. We also consider the effect of multiple ISM absorption components. We discuss the relevance of this result for exoplanet studies and revise the

  6. Experimental and theoretical comparison of the precision of flame atomic absorption, fluorescence, and emission measurements

    International Nuclear Information System (INIS)

    Bower, N.W.; Ingle, J.D. Jr.

    1981-01-01

    Theoretical equations and experimental evaluation procedures for the determination of the precision of flame atomic absorption, emission, and fluorescence measurements are presented. These procedures and noise power spectra are used to evaluate the precision and noise characteristics of atomic copper measurements with all three techniques under the same experimental conditions in a H 2 -air flame. At the detection limit, emission and fluorescence measurements are limited by background emission shot and flicker noise whereas absorption measurements are limited by flame transmission lamp flicker noise. Analyte flicker noise limits precision at higher analyte concentrations for all three techniques. Fluctutations in self-absorption and the inner filter effect are shown to contribute to the noise in atomic emission and fluorescence measurements

  7. A new method for measuring the interdiffusion coefficient in a liquid metal alloy; Nouvelle methode de mesure du coefficient d'interdiffusion dans un alliage liquide metallique

    Energy Technology Data Exchange (ETDEWEB)

    Gonella, Ch.; Blanchet, A.; Le Ny, J. [CEA Saclay, Dept. des Procedes d' Enrichissement (DCC/DPE/SPCP), 91 - Gif-sur-Yvette (France)

    2000-07-01

    A knowledge of diffusion mechanisms and the values of associated coefficients is essential for controlling changes in heated materials and alloys with time. In contrast to solids, where a large literature is available, little research has been done on diffusion coefficients in liquid metals. This is due to experimental difficulties: compatibility of the liquid with the measurement cell, high vapor pressures, convective processes. A significant improvement was achieved by the use of the shear cell, which puts the elements into contact with each other at the selected working temperature and isolates the different sections at the end of the diffusion time. This method employs radioactive sources, generally as tracers, which need counting after cooling. Each alloy composition requires a test, increasing the number of experiments needed. To eliminate the use of tracers, we propose a method based on the shear cell procedure for putting the liquids into contact, which allows determination of the interdiffusion coefficient in a liquid alloy in a single experiment from the measurement of a mass spectrometer signal. The experimental principle is shown schematically. Iron is in the upper ceramic cell and uranium in the lower. After stabilizing the temperature and adjusting the detected signal of the spectrometer to the mass of iron, the iron and uranium are brought into contact by rotating the upper cell from outside the vacuum chamber. The diffusion experiment consists in recording the decrease over time of the signal received by the spectrometer. During the diffusion period, the upper surface of the iron is enriched in uranium, thereby decreasing the thermodynamic activity of the iron and the detected signal. (authors)

  8. Absorption cross-section measurements of methane, ethane, ethylene and methanol at high temperatures

    KAUST Repository

    Alrefae, Majed

    2014-09-01

    Mid-IR absorption cross-sections are measured for methane, ethane, ethylene and methanol over 2800-3400 cm-1 (2.9-3.6 μm) spectral region. Measurements are carried out using a Fourier-Transform-Infrared (FTIR) spectrometer with temperatures ranging 296-1100 K and pressures near atmospheric. As temperature increases, the peak cross-sections decrease but the wings of the bands increase as higher rotational lines appear. Integrated band intensity is also calculated over the measured spectral region and is found to be a very weak function of temperature. The absorption cross-sections of the relatively small fuels studied here show dependence on the bath gas. This effect is investigated by studying the variation of absorption cross-sections at 3.392 μm using a HeNe laser in mixtures of fuel and nitrogen, argon, or helium. Mixtures of fuel with He have the highest value of absorption cross-sections followed by Ar and N2. Molecules with narrow absorption lines, such as methane and methanol, show strong dependence on bath gas than molecules with relatively broader absorption features i.e. ethane and ethylene. © 2014 Elsevier Inc. All rights reserved.

  9. The Consequences of Ignoring Measurement Invariance for Path Coefficients in Structural Equation Models

    Directory of Open Access Journals (Sweden)

    Nigel eGuenole

    2014-09-01

    Full Text Available We report a Monte Carlo study examining the effects of 2 strategies for handling measurement non-invariance - modeling and ignoring non-invariant items - on structural regression coefficients between latent variables measured with Item Response Theory models for categorical indicators. These strategies were examined across 4 levels and 3 types of non-invariance – non-invariant loadings, non-invariant thresholds, and combined non-invariance on loadings and thresholds - in simple, partial, mediated and moderated regression models where the non-invariant latent variable occupied predictor, mediator, and criterion positions in the structural regression models. When non-invariance is ignored in the latent predictor, the focal group regression parameters are biased in the opposite direction to the difference in loadings and thresholds relative to the referent group (i.e. lower loadings and thresholds for the focal group lead to overestimated regression parameters. With criterion non-invariance, the focal group regression parameters are biased in the same direction as the difference in loadings and thresholds relative to the referent group. While unacceptable levels of parameter bias were confined to the focal group, bias occurred at considerably lower levels of ignored non-invariance than was previously recognized in referent and focal groups.

  10. Hybrid aligned nematic based measurement of the sum (e1+e3) of the flexoelectric coefficients

    Science.gov (United States)

    Tartan, Chloe C.; Elston, Steve J.

    2015-02-01

    A new method has been established for the measurement of the sum of the flexoelectric coefficients e1+e3 in liquid crystals by exploiting the properties of highly ionic materials in order to screen out the internal bias due to the different surface alignment polarities in a Hybrid Aligned Nematic (HAN) liquid crystal device. It has been shown that responses to pulses are independent of the external offset of a signal applied to a HAN device filled with a highly ionic material. Driving the device with step changes in the offset leads to either a transient increase or transient decrease in the response, depending on the polarity of the offset, while the equilibrium response remains the same. The time constant of the transient effect is consistent with the relaxation time of the ions present in the material. Assuming these ions screen out the internal bias completely, the remaining response can be used as a measure of the flexoelectric effect. Based on this approach, a value of (10 ± 2) pC m-1 was found for the modulus of the flexoelectric sum in the standard commercial eutectic E70 nematic liquid crystal mixture.

  11. Measurements of the static friction coefficient between bone and muscle tissues.

    Science.gov (United States)

    Shacham, Sharon; Castel, David; Gefen, Amit

    2010-08-01

    This study aimed at measuring the static coefficient of friction (mu) between bone and skeletal muscle tissues in order to support finite element (FE) modeling in orthopaedic and rehabilitation research, where such contact conditions need to be defined. A custom-made friction meter (FM) that employs the load cell and motion-controlled loading arm of a materials testing machine was designed for this study. The FM was used to measure mu between fresh ulna bones and extensor muscles surrounding the ulna, which were harvested from five young adult pigs. Mean bone-muscle mu were between 0.36 and 0.29, decreased with the increase in loads applied on the bone (p<0.05) and plateaued at a mean approximately 0.3 for loads exceeding 4 N. Hence, for FE modeling of bone-muscle contacts through which loads with magnitudes of kgs to 10s-of-kgs are transferred, assuming mu of approximately 0.3 appears to be appropriate.

  12. Further validation of the plasma isotope ratio method for measurement of cholesterol absorption in man.

    Science.gov (United States)

    Samuel, P; McNamara, D J; Ahrens, E H; Crouse, J R; Parker, T

    1982-03-01

    Recently we evaluated an isotope ratio method (IRM) for measurement of cholesterol absorption in 14 patients (15 experiments) hospitalized in the metabolic ward by comparing it to simultaneous measurements with a fecal radioactivity method (FRM) and found good to excellent agreement between two procedures (Samuel, P., J. R. Crouse, and E. H. Ahrens, Jr. 1978 J. Lipid Res. 19: 82-93). This comparison has now been extended to additional studies carried out in eight hospitalized patients (19 experiments). Of the 34 comparisons between the IRM and the FRM in our hands, 29 were technically acceptable (chromic oxide fecal recovery >/=80%): percent cholesterol absorption was 43.1 +/- 12% by the FRM and 46.0 +/- 11% by the IRM, exhibiting an accuracy within 3.5% at the 95% and 4.7% at the 99% confidence levels. In addition, various procedural modifications of the IRM were studied in out-patients. The measurement of isotope ratios in a single blood sample (analyzed in sextuplicate) on the third day (or later) following the tests gave identical results to those obtained from six to eight daily blood samplings. Blood samples drawn at any time during the day gave cholesterol absorption values similar to those obtained from samples drawn following an overnight fast. Absorption tests carried out before and 1 hr after breakfast, lunch, or dinner, or giving the oral isotope in three divided daily doses all yielded identical results with tests carried out in the am in the fasting state. Cholesterol absorption was markedly reduced when the oral radiolabeled cholesterol was administered in orange juice vs. liquid formula, milk or a solution of glucose and amino acids, consistent with the well-known fact that gallbladder contraction is a critical requirement of cholesterol absorption. A meal high in cholesterol consumed on the day of the test did not influence the results of the absorption measurements. Furthermore, addition of three eggs per day (~750mg cholesterol) for 3 weeks to a

  13. The concept of measurement of thermal neutron absorption cross section in small samples

    International Nuclear Information System (INIS)

    Czubek, J.A.

    1980-01-01

    Theoretical principles of the method of measurement of the absorption cross section for thermal neutrons are presented in the one velocity approach. In consecutive measurements the sample investigated is enveloped in shells of a known moderator of varying thickness and irradiated with the pulsed beam of fast neutrons. The die-away rate of thermal neutrons escaping from such a system is measured. The absorption cross section of the unknown sample is found as the intersection of the experimental curve (die-away rate viz. thickness of the moderator) with the theoretical one calculated for the case of the zero value of the material buckling of the sample. (author)

  14. Realization of a new sensor for a real-time local measurement of tissue optical coefficients

    Science.gov (United States)

    Ettori, Dominique; Tinet, Eric; Nguyen Tien, Tuan; Revel, Franck; Tualle, Jean-Michel; Avrillier, Sigrid

    2004-09-01

    We develop a new sensor for the local in vivo measurement of optical coefficients near the surface of a tissue. To be less sensitive to the heterogeneous surface of the sample, we decided to perform space and time-resolved measurements. The sensor is a bundle of fibres. The excitation light is generated by a mode-locked Ti-Sa laser at 800nm and filtered by a 1.5nm bandwidth dielectric filter in order to limit group velocity dispersion in the monomode excitation fibre. The reflectance light is collected by gradient index fibres at 250μm and 1.3 mm from the source. The detection is performed with a Hamamatsu M5675 synchroscan streak camera. The whole system allows a time resolution of about 5ps. We made comparisons between time and space resolved Monte-Carlo numerical simulations and in vitro experimental data obtained with unskimmed UHT milk which is a known reference medium. The system does not rely on the absolute value of the reflected light intensity nor depend on the intensity ratio between different fibres since the distance between the medium and the fibres as well as the fibres tip cleanness cannot be guaranteed in vivo. As a consequence we use global characteristic of the time resolved curves such as the FWHM and their evolution with the distance from the source. The good agreement between the simulations and the experimental data lets us envisage to use numerically pre-computed tables for a real time determination of the local scattering mean free path and the anisotropy factor . We soon will be able to perform measurements with biological tissues, in vitro in a first time and in vivo in a second time.

  15. Repeatability of n-octanol/water partition coefficient values between liquid chromatography measurement methods.

    Science.gov (United States)

    Saranjampour, Parichehr; Armbrust, Kevin

    2018-03-20

    The n-octanol/water partition coefficient (K OW ) is a physical/chemical property that is extensively used for regulatory and environmental risk and exposure assessments. The K OW value can estimate various chemical properties such as water solubility, bioavailability, and toxicity using quantitative structure-activity relationships which demands an accurate knowledge of this property. The present investigation aims to compare outcomes of three commonly cited methods of K OW measurement in the literature for six hydrophobic chemicals with insecticidal functions as well as highly volatile petroleum constituents. This measurement has been difficult to obtain for the selected pyrethroid insecticides, cypermethrin, and bifenthrin and is a novel measurement for the latter: polycyclic aromatic sulfur heterocycles, dibenzothiophene (DBT), and three of its alkyl derivatives except for DBT. The K OW values were obtained using two liquid chromatographic methods with isocratic and gradient programming, and the slow-stirring method following OECD 117 and 123 guidelines, respectively. The mean log K OW values of bifenthrin, cypermethrin, DBT, methyl-DBT, dimethyl-DBT, and diethyl-DBT were 8.4 ± 0.1, 6.0 ± 0.3, 4.8 ± 0.0, 5.4 ± 0.1, 6.0 ± 0.1, and 6.8 ± 0.0 using the HPLC method with gradient programing. The K OW values were significantly reproducible within a method, however, not between the methods. Results suggest assessing a chemical's property and environmental risk and exposure solely based on the K OW value should be practiced with caution.

  16. Capturing Absorptive Capacity: Concepts, Determinants, Measurement Modes and Role in Open Innovation

    Directory of Open Access Journals (Sweden)

    Lewandowska Małgorzata Stefania

    2015-03-01

    Full Text Available Absorptive capacity (ACAP enables firm to adjust to a rapidly changing environment and achieve sustained competitive advantage. This study contributes to the existing body of knowledge on ACAP by providing a comprehensive literature review of the various conceptual attributes of the construct, its determinants, outcomes, and positive and negative consequences of using its input-oriented, output-oriented, and perceptive measurement modes. Proposals for constructing ACAP based on the Community Innovation Survey (CIS empirically illustrate for the conceptual part of the paper. Additionally, combining concepts of absorptive capacity and open innovation (which is still rare in the literature provides a new perspective on the role of absorptive capacity in opening up the innovation process. This advances the understanding of both inter-related proposals. The article also identifies key problems and formulates future research directions to improve the multi-level characteristics of absorptive capacity.

  17. Diagnosis of laser ablated carbon particles measured by time-resolved X-ray absorption spectroscopy

    International Nuclear Information System (INIS)

    Miyashita, Atsumi; Yoda, Osamu; Ohyanagi, T.; Murakami, K.

    1995-01-01

    The time and space resolved properties of laser ablated carbon particles were measured by X-ray absorption spectroscopy using LPX as an X-ray source. The energy density of the irradiation laser on the sample was in the range of 0.5-20J/cm 2 and the time delay was varied between 0 and 120ns. The absorption spectra exhibited several peaks originated from level to level transitions and an intense broad absorption in the energy range of C-K edge. At a delay time of 120ns, the absorption peak from 1s→2p transition of neutral carbon atom (C 0 ), C - , C + and C 2+ ions were observed. The absorption peak from C 0 was stronger as the probing position was closer to the sample surface and decreased rapidly with distance from the sample surface. The absorption peak C 2+ ion was observed only at comparatively distant positions from surface. The maximum speeds of highly charged ions were faster than that of neutral atoms and negative charged ions. The neutral atom and lower charged ions were emitted from the sample even after laser irradiation. The spatial distributions of the laser ablated carbon particles in the localized helium gas environment were measured. In the helium gas environment, the ablation plume was depressed by the helium cloud generated on the top of ablation plume. (author)

  18. Experimental friction coefficients for bovine cartilage measured with a pin-on-disk tribometer: testing configuration and lubricant effects.

    Science.gov (United States)

    Shi, Liu; Sikavitsas, Vassilios I; Striolo, Alberto

    2011-01-01

    The friction coefficient between wet articular cartilage surfaces was measured using a pin-on-disk tribometer adopting different testing configurations: cartilage-on-pin vs. alumina-on-disk (CA); cartilage-on-pin vs. cartilage-on-disk (CC); and alumina-on-pin vs. cartilage-on-disk (AC). Several substances were dissolved in the phosphate buffered saline (PBS) solution to act as lubricants: 10,000 molecular weight (MW) polyethylene glycol (PEG), 100,000 MW PEG, and chondroitin sulfate (CS), all at 100 mg/mL concentration. Scanning electron microscopy photographs of the cartilage specimens revealed limited wear due to the experiment. Conducting the experiments in PBS solutions we provide evidence according to which a commercial pin-on-disk tribometer allows us to assess different lubrication mechanisms active in cartilage. Specifically, we find that the measured friction coefficient strongly depends on the testing configuration. Our results show that the friction coefficient measured under CC and AC testing configurations remains very low as the sliding distance increases, probably because during the pin displacement the pores present in the cartilage replenish with PBS solution. Under such conditions the fluid phase supports a large load fraction for long times. By systematically altering the composition of the PBS solution we demonstrate the importance of solution viscosity in determining the measured friction coefficient. Although the friction coefficient remains low under the AC testing configuration in PBS, 100 mg/mL solutions of both CS and 100,000 MW PEG in PBS further reduce the friction coefficient by ~40%. Relating the measured friction coefficient to the Hersey number, our results are consistent with a Stribeck curve, confirming that the friction coefficient of cartilage under the AC testing configuration depends on a combination of hydrodynamic, boundary, and weep bearing lubrication mechanisms.

  19. Methodology for using prompt gamma activation analysis to measure the binary diffusion coefficient of a gas in a porous medium

    International Nuclear Information System (INIS)

    Rios Perez, Carlos A.; Biegalski, Steve R.; Deinert, Mark R.

    2012-01-01

    Highlights: ► Prompt gamma activation analysis is used to study gas diffusion in a porous system. ► Diffusion coefficients are determined using prompt gamma activation analysis. ► Predictions concentrations fit experimental measurements with an R 2 of 0.98. - Abstract: Diffusion plays a critical role in determining the rate at which gases migrate through porous systems. Accurate estimates of diffusion coefficients are essential if gas transport is to be accurately modeled and better techniques are needed that can be used to measure these coefficients non-invasively. Here we present a novel method for using prompt gamma activation analysis to determine the binary diffusion coefficients of a gas in a porous system. Argon diffusion experiments were conducted in a 1 m long, 10 cm diameter, horizontal column packed with a SiO 2 sand. The temporal variation of argon concentration within the system was measured using prompt gamma activation analysis. The binary diffusion coefficient was obtained by comparing the experimental data with the predictions from a numerical model in which the diffusion coefficient was varied until the sum of square errors between experiment and model data was minimized. Predictions of argon concentration using the optimal diffusivity fit experimental measurements with an R 2 of 0.983.

  20. Measurement of absorption with a p-u sound intensity probe in an impedance tube

    DEFF Research Database (Denmark)

    Liu, Yang; Jacobsen, Finn

    2005-01-01

    An alternative method of measuring the normal-incidence sound absorption of a sample of material in an impedance tube is examined. The method is based on measurement of the sound pressure and the normal component of the particle velocity using a "p-u" sound intensity probe. This technique...

  1. Estimation of monthly Angstrom-Prescott equation coefficients from measured daily data in Toledo, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Almorox, J.; Hontoria, C. [Universidad Politecnica de Madrid (Spain). Dpto. De Edafologia; Benito, M. [Universidad Politecnica de Madrid (Spain). Dpto. De Silvopasicultura

    2005-05-01

    In this study, daily global radiation for Toledo (39{sup o}53'05''N, 4{sup o}02'58''W, Spain) were utilized to determine monthly-specific equations for estimating global solar radiation from sunshine hours and to obtain improved fits to monthly Angstrom-Prescott's coefficients. Models were compared using the root mean square error (RMSE), the mean bias error (MBE) and the t-statistic. According to our results, all the models fitted the data adequately and can be used to estimate the specific monthly global solar radiation. Average RMSE and MBE for comparison between observed and estimated global radiation were 1.260 and -0.002 MJ m{sup -2} day{sup -1}, respectively. The t-statistic was used as the best indicator, this indicator depends on both, and is more effective for determining the model performance. The agreement between the estimated and the measured data were remarkable and the method was recommended for use in Toledo (Spain). (author)

  2. Measurements of Drag Coefficients and Rotation Rates of Free-Falling Helixes

    KAUST Repository

    Al-Omari, Abdulrhaman A.

    2016-05-01

    The motion of bacteria in the environment is relevant to several fields. At very small scales and with simple helical shapes, we are able to describe experimentally and mathematically the motion of solid spirals falling freely within a liquid pool. Using these shapes we intend to mimic the motion of bacteria called Spirochetes. We seek to experimentally investigate the linear and the rotational motion of such shapes. A better understanding of the dynamics of this process will be practical not only on engineering and physics, but the bioscience and environmental as well. In the following pages, we explore the role of the shape on the motion of passive solid helixes in different liquids. We fabricate three solid helical shapes and drop them under gravity in water, glycerol and a mixture of 30% glycerol in water. That generated rotation due to helical angle in water. However, we observe the rotation disappear in glycerol. The movement of the solid helical shapes is imaged using a high-speed video camera. Then, the images are analyzed using the supplied software and a computer. Using these simultaneous measurements, we examine the terminal velocity of solid helical shapes. Using this information we computed the drag coefficient and the drag force. We obtain the helical angular velocity and the torque applied to the solid. The results of this study will allow us to more accurately predict the motion of solid helical shape. This analysis will also shed light onto biological questions of bacteria movement.

  3. Measurement of thermal expansion coefficient of graphene diaphragm using optical fiber Fabry–Perot interference

    International Nuclear Information System (INIS)

    Li, Cheng; Liu, Qianwen; Peng, Xiaobin; Fan, Shangchun

    2016-01-01

    Application of the Fabry–Perot (FP) interference method for determining the coefficient of thermal expansion (CTE) of a graphene diaphragm is investigated in this paper. A miniature extrinsic FP interferometric (EFPI) sensor was fabricated by using an approximate 8-layer graphene diaphragm. The extremely thin diaphragm was transferred onto the endface of a ferrule with an inner diameter of 125 μ m, and van der Waals interactions between the graphene diaphragm and its substrate created a low finesse FP interferometer with a cavity length of 36.13 μ m. Double reference FP cavities using two cleaved optical fibers as reflectors were also constructed to differentially cancel the thermal expansion effects of the trapped gas and adhesive material. A temperature test demonstrated an approximate cavity length change of 166.1 nm °C −1 caused by film thermal expansion in the range of 20–60 °C. Then along with the established thermal deformation model of the suspended circular diaphragm, the calculated CTE ranging from  −9.98  ×  10 −6 K −1 to  −2.09  ×  10 −6 K −1 conformed well to the previously measured results. The proposed method would be applicable in other types of elastic materials as the sensitive diaphragm of an EFPI sensor over a wide temperature range. (paper)

  4. Mass-transport limitation to in-cloud reaction rates: Implications of new accommodation coefficient measurements

    International Nuclear Information System (INIS)

    Schwartz, S.E.

    1988-10-01

    Although it has been recognized for some time that the rate of reactive uptake of gases in cloudwater can depend on the value of the mass-accommodation coefficient (α) describing interfacial mass transport (MT), definitive evaluation of such rates is only now becoming possible with the availability of measurements of α for gases of atmospheric interest at air-water interfaces. Examination of MT limitation to the rate of in-cloud aqueous-phase oxidation of SO 2 by O 3 and H 2 O 2 shows that despite the low value of α/sub O3/ (5 /times/ 10/sup /minus/4/), interfacial MT of this species is not limiting under essentially all conditions of interest; the high values of α for SO 2 (≥ 0.2) and H 2 O 2 (≥ 0.08) indicate no interfacial MT limitation for these species also. Although gas- and aqueous-phase MT can be limiting under certain extremes of conditions, treating the system as under chemical kinetic control is generally an excellent approximation. Interfacial MT limitation also is found not to hinder the rate of H 2 O 2 formation by aqueous-phase disproportionation of HO 2 . Finally, the rapid uptake of N 2 O 5 by cloud droplets implies that the yield of aqueous HNO 3 from in-cloud gas-phase oxidation of NO 2 by O 3 can be substantial even under daytime conditions. This report consists of copies of viewgraphs prepared for this presentation

  5. Value of apparent diffusion coefficient measurement for discrimination of focal benign and malignant hepatic masses.

    Science.gov (United States)

    Kilickesmez, O; Bayramoglu, S; Inci, E; Cimilli, T

    2009-02-01

    The purpose of our study was to investigate the value of diffusion-weighted magnetic resonance imaging (DW-MRI) to discriminate benign and malignant focal lesions of the liver using parallel imaging technique. A total of 77 patients and 65 healthy controls were enrolled in the study. DW-MRI was performed with b-factors of 0, 500 and 1000 s/mm(2), and the apparent diffusion coefficients (ADC) values of the normal liver and the lesions were calculated. The mean ADC value of the focal liver lesions were as follows: simple cysts (3.16 +/- 0.18 x 10(-3) mm(2)/s), hydatid cysts (2.58 +/- 0.53 x 10(-3) mm(2)/s), hemangiomas (1.97 +/- 0.49 x 10(-3) mm(2)/s), metastases (1.14 +/- 0.41 x 10(-3) mm(2)/s) and hepatocellular carcinomas (HCC) (1.15 +/- 0.36 x 10(-3) mm(2)/s). The mean ADC values of all the disease groups were statistically significant when compared with the mean ADC value of the normal liver (1.56 +/- 0.14 x 10(-3) mm(2)/s), (P values of hemangiomas and HCC metastases (P present study showed that ADC measurement has the potential to differentiate benign and malignant focal hepatic lesions. We propose to add DW sequence in the MR protocol for the detection and quantitative discrimination of hepatic pathologies.

  6. Can two dots form a Gestalt? Measuring emergent features with the capacity coefficient.

    Science.gov (United States)

    Hawkins, Robert X D; Houpt, Joseph W; Eidels, Ami; Townsend, James T

    2016-09-01

    While there is widespread agreement among vision researchers on the importance of some local aspects of visual stimuli, such as hue and intensity, there is no general consensus on a full set of basic sources of information used in perceptual tasks or how they are processed. Gestalt theories place particular value on emergent features, which are based on the higher-order relationships among elements of a stimulus rather than local properties. Thus, arbitrating between different accounts of features is an important step in arbitrating between local and Gestalt theories of perception in general. In this paper, we present the capacity coefficient from Systems Factorial Technology (SFT) as a quantitative approach for formalizing and rigorously testing predictions made by local and Gestalt theories of features. As a simple, easily controlled domain for testing this approach, we focus on the local feature of location and the emergent features of Orientation and Proximity in a pair of dots. We introduce a redundant-target change detection task to compare our capacity measure on (1) trials where the configuration of the dots changed along with their location against (2) trials where the amount of local location change was exactly the same, but there was no change in the configuration. Our results, in conjunction with our modeling tools, favor the Gestalt account of emergent features. We conclude by suggesting several candidate information-processing models that incorporate emergent features, which follow from our approach. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Measurement of gas/water uptake coefficients for trace gases active in the marine environment

    Energy Technology Data Exchange (ETDEWEB)

    Davidovits, P. (Boston Coll., Chestnut Hill, MA (United States). Dept. of Chemistry); Worsnop, D.W.; Zahniser, M.S.; Kolb, C.E. (Aerodyne Research, Inc., Billerica, MA (United States). Center for Chemical and Environmental Physics)

    1992-02-01

    Ocean produced reduced sulfur compounds including dimethylsulfide (DMS), hydrogen sulfide (H{sub 2}S), carbon disulfide (CS{sub 2}), methyl mercaptan (CH{sub 3}CH) and carbonyl sulfide (OCS) deliver a sulfur burden to the atmosphere which is roughly equal to sulfur oxides produced by fossil fuel combustion. These species and their oxidation products dimethyl sulfoxide (DMSO), dimethyl sulfone (DMSO{sub 2}) and methane sulfonic acid (MSA) dominate aerosol and CCN production in clean marine air. Furthermore, oxidation of reduced sulfur species will be strongly influenced by NO{sub x}/O{sub 3} chemistry in marine atmospheres. The multiphase chemical processes for these species must be understood in order to study the evolving role of combustion produced sulfur oxides over the oceans. We have measured the chemical and physical parameters affecting the uptake of reduced sulfur compounds, their oxidation products, ozone, and nitrogen oxides by the ocean's surface, and marine clouds, fogs, and aerosols. These parameters include: gas/surface mass accommodation coefficients; physical and chemically modified (effective) Henry's law constants; and surface and liquid phase reaction constants. These parameters are critical to understanding both the interaction of gaseous trace species with cloud and fog droplets and the deposition of trace gaseous species to dew covered, fresh water and marine surfaces.

  8. A 2-Micron Pulsed Integrated Path Differential Absorption Lidar Development For Atmospheric CO2 Concentration Measurements

    Science.gov (United States)

    Yu, Jirong; Petros, Mulugeta; Reithmaier, Karl; Bai, Yingxin; Trieu, Bo C.; Refaat, Tamer F.; Kavaya, Michael J.; Singh, Upendra N.

    2012-01-01

    A 2-micron pulsed, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric CO2 concentration measurements via direct detection method is being developed at NASA Langley Research Center. This instrument will provide an alternate approach to measure atmospheric CO2 concentrations with significant advantages. A high energy pulsed approach provides high-precision measurement capability by having high signal-to-noise level and unambiguously eliminates the contamination from aerosols and clouds that can bias the IPDA measurement.

  9. Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy

    Science.gov (United States)

    Hallacoglu, Bertan; Sassaroli, Angelo; Wysocki, Michael; Guerrero-Berroa, Elizabeth; Schnaider Beeri, Michal; Haroutunian, Vahram; Shaul, Merav; Rosenberg, Irwin H.; Troen, Aron M.; Fantini, Sergio

    2012-08-01

    We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85±6 years) and 19 young adults (mean age, 28±4 years). Non-invasive measurements were obtained on the forehead using a commercially available multi-distance frequency-domain system and analyzed using a diffusion theory model for a semi-infinite, homogeneous medium with semi-infinite boundary conditions. Our study included repeat measurements, taken five months apart, on 16 elderly volunteers that demonstrate intra-subject reproducibility of the absolute measurements with cross-correlation coefficients of 0.9 for absorption coefficient (μa), oxy-hemoglobin concentration ([HbO2]), and total hemoglobin concentration ([HbT]), 0.7 for deoxy-hemoglobin concentration ([Hb]), 0.8 for hemoglobin oxygen saturation (StO2), and 0.7 for reduced scattering coefficient (). We found significant differences between the two age groups. Compared to young subjects, elderly subjects had lower cerebral [HbO2], [Hb], [HbT], and StO2 by 10±4 μM, 4±3 μM, 14±5 μM, and 6%±5%, respectively. Our results demonstrate the reliability and robustness of multi-distance near-infrared spectroscopy measurements based on a homogeneous model in the human forehead on a large sample of human subjects. Absolute, non-invasive optical measurements on the brain, such as those presented here, can significantly advance the development of NIRS technology as a tool for monitoring resting/basal cerebral perfusion, hemodynamics, oxygenation, and metabolism.

  10. Determining CDOM Absorption Spectra in Diverse Coastal Environments Using a Multiple Pathlength, Liquid Core Waveguide System. Measuring the Absorption of CDOM in the Field Using a Multiple Pathlength Liquid Waveguide System

    Science.gov (United States)

    Miller, Richard L.; Belz, Mathias; DelCastillo, Carlos; Trzaska, Rick

    2000-01-01

    We evaluated the accuracy, sensitivity and precision of a multiple pathlength, liquid core waveguide (MPLCW) system for measuring colored dissolved organic matter (CDOM) absorption in the UV-visible spectral range (370-700 nm). The MPLCW has four optical paths (2.0, 9.8, 49.3, and 204 cm) coupled to a single Teflon AF sample cell. Water samples were obtained from inland, coastal and ocean waters ranging in salinity from 0 to 36 PSU. Reference solutions for the MPLCW were made having a refractive index of the sample. CDOM absorption coefficients, a(sub CDOM), and the slope of the log-linearized absorption spectra, S, were compared with values obtained using a dual-beam spectrophotometer. Absorption of phenol red secondary standards measured by the MPLCW at 558 nm were highly correlated with spectrophotometer values (r > 0.99) and showed a linear response across all four pathlengths. Values of a(sub CDOM) measured using the MPLCW were virtually identical to spectrophotometer values over a wide range of concentrations. The dynamic range of a(sub CDOM) for MPLCW measurements was 0.002 - 231.5/m. At low CDOM concentrations (a(sub 370) < 0.1/m) spectrophotometric a(sub CDOM) were slightly greater than MPLCW values and showed larger fluctuations at longer wavelengths due to limitations in instrument precision. In contrast, MPLCW spectra followed an exponential to 600 nm for all samples. The maximum deviation in replicate MPLCW spectra was less than 0.001 absorbance units. The portability, sampling, and optical characteristics of a MPLCW system provide significant enhancements for routine CDOM absorption measurements in a broad range of natural waters.

  11. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    Science.gov (United States)

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Agnostic stacking of intergalactic doublet absorption: measuring the Ne VIII population

    Science.gov (United States)

    Frank, Stephan; Pieri, Matthew M.; Mathur, Smita; Danforth, Charles W.; Shull, J. Michael

    2018-05-01

    We present a blind search for doublet intergalactic metal absorption with a method dubbed `agnostic stacking'. Using a forward-modelling framework, we combine this with direct detections in the literature to measure the overall metal population. We apply this novel approach to the search for Ne VIII absorption in a set of 26 high-quality COS spectra. We probe to an unprecedented low limit of log N>12.3 at 0.47≤z ≤1.34 over a path-length Δz = 7.36. This method selects apparent absorption without requiring knowledge of its source. Stacking this mixed population dilutes doublet features in composite spectra in a deterministic manner, allowing us to measure the proportion corresponding to Ne VIII absorption. We stack potential Ne VIII absorption in two regimes: absorption too weak to be significant in direct line studies (12.3 13.7). We do not detect Ne VIII absorption in either regime. Combining our measurements with direct detections, we find that the Ne VIII population is reproduced with a power-law column density distribution function with slope β = -1.86 ^{+0.18 }_{ -0.26} and normalization log f_{13.7} = -13.99 ^{+0.20 }_{ -0.23}, leading to an incidence rate of strong Ne VIII absorbers dn/dz =1.38 ^{+0.97 }_{ -0.82}. We infer a cosmic mass density for Ne VIII gas with 12.3 < log N < 15.0 of Ω _{{{Ne {VIII}}}} = 2.2 ^{+1.6 }_{ _-1.2} × 10^{-8}, a value significantly lower that than predicted by recent simulations. We translate this density into an estimate of the baryon density Ωb ≈ 1.8 × 10-3, constituting 4 per cent of the total baryonic mass.

  13. Agnostic Stacking of Intergalactic Doublet Absorption: Measuring the Ne VIII Population

    Science.gov (United States)

    Frank, Stephan; Pieri, Matthew M.; Mathur, Smita; Danforth, Charles W.; Michael Shull, J.

    2018-02-01

    We present a blind search for doublet intergalactic metal absorption with a method dubbed `agnostic stacking'. Using a forward-modelling framework we combine this with direct detections in the literature to measure the overall metal population. We apply this novel approach to the search for Ne VIII absorption in a set of 26 high-quality COS spectra. We probe to an unprecedented low limit of log N>12.3 at 0.47≤z ≤1.34 over a pathlength Δz = 7.36. This method selects apparent absorption without requiring knowledge of its source. Stacking this mixed population dilutes doublet features in composite spectra in a deterministic manner, allowing us to measure the proportion corresponding to Ne VIII absorption. We stack potential Ne VIII absorption in two regimes: absorption too weak to be significant in direct line studies (12.3 13.7). We do not detect Ne VIII absorption in either regime. Combining our measurements with direct detections, we find that the Ne VIII population is reproduced with a power law column density distribution function with slope β = -1.86+0.18-0.26 and normalisation log f_{13.7} = -13.99+0.20-0.23, leading to an incidence rate of strong Ne VIII absorbers dn/dz =1.38+0.97-0.82. We infer a cosmic mass density for Ne VIII gas with 12.3 < log N < 15.0 of Ω _{Ne VIII} = 2.2+1.6-1.2 × 10^{-8}, a value significantly lower that than predicted by recent simulations. We translate this density into an estimate of the baryon density Ωb ≈ 1.8 × 10-3, constituting 4% of the total baryonic mass.

  14. Measurement of total-body cobalt-57 vitamin B12 absorption with a gamma camera

    International Nuclear Information System (INIS)

    Cardarelli, J.A.; Slingerland, D.W.; Burrows, B.A.; Miller, A.

    1985-01-01

    Previously described techniques for the measurement of the absorption of [ 57 Co]vitamin B 12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room

  15. Laboratory measurements of the coefficient of thermal expansion of Olkiluoto drill core samples

    International Nuclear Information System (INIS)

    Aakesson, U.

    2012-04-01

    The coefficient of thermal expansion and the wet density has been determined on 22 specimens from the ONKALO drillholes ONK-PP167, ONK-PP199, ONK-PP224, ONK-PP225 and ONK-PP226, Olkiluoto, Finland. The coefficient of thermal expansion has been determined in the temperature interval 20-60 deg C. The results indicated that the thermal expansion was almost linear, and the coefficient of thermal expansion for the investigated specimens range between 3.2 and 14.4 x 10 -6 mm/mm deg C, and the wet density between 2,610 and 2,820 kg/m 3 . The granite pegmatite has slightly lower coefficient of thermal expansion and wet density than gneissic rocks. (orig.)

  16. Measurement of K-shell absorption jump factors and jump ratios in some lanthanide elements using EDXRF technique

    International Nuclear Information System (INIS)

    Polat, Recep; İçelli, Orhan; Yalçın, Zeynel; Pesen, Erhan; Orak, Salim

    2013-01-01

    Highlights: ► Mass attenuation coefficients, jump factor and jump ratio for lanthanide elements are obtained. ► The method used in this experiment is combined both transmission and scattering geometry. ► Secondary gamma rays energy is 59.5 keV. ► Experimental values of jump factor and jump ratio for K shell are new. ► The experimental values are in good agreement with those calculated theoretically. - Abstract: 59.5 keV gamma rays scattered by an aluminum foil have been used as a radiation source to measure the absorption jump factor and jump ratios for absorbers Ce, Pr, Nd, Sm, Eu and Tb. The theoretical and experimental values are compared with the corresponding ones in the literature

  17. Rate Coefficients of C1 and C2 Criegee Intermediate Reactions with Formic and Acetic Acid Near the Collision Limit: Direct Kinetics Measurements and Atmospheric Implications**

    Science.gov (United States)

    Welz, Oliver; Eskola, Arkke J; Sheps, Leonid; Rotavera, Brandon; Savee, John D; Scheer, Adam M; Osborn, David L; Lowe, Douglas; Murray Booth, A; Xiao, Ping; Anwar H Khan, M; Percival, Carl J; Shallcross, Dudley E; Taatjes, Craig A

    2014-01-01

    Rate coefficients are directly determined for the reactions of the Criegee intermediates (CI) CH2OO and CH3CHOO with the two simplest carboxylic acids, formic acid (HCOOH) and acetic acid (CH3COOH), employing two complementary techniques: multiplexed photoionization mass spectrometry and cavity-enhanced broadband ultraviolet absorption spectroscopy. The measured rate coefficients are in excess of 1×10−10 cm3 s−1, several orders of magnitude larger than those suggested from many previous alkene ozonolysis experiments and assumed in atmospheric modeling studies. These results suggest that the reaction with carboxylic acids is a substantially more important loss process for CIs than is presently assumed. Implementing these rate coefficients in global atmospheric models shows that reactions between CI and organic acids make a substantial contribution to removal of these acids in terrestrial equatorial areas and in other regions where high CI concentrations occur such as high northern latitudes, and implies that sources of acids in these areas are larger than previously recognized. PMID:24668781

  18. Rate coefficients of C(1) and C(2) Criegee intermediate reactions with formic and acetic Acid near the collision limit: direct kinetics measurements and atmospheric implications.

    Science.gov (United States)

    Welz, Oliver; Eskola, Arkke J; Sheps, Leonid; Rotavera, Brandon; Savee, John D; Scheer, Adam M; Osborn, David L; Lowe, Douglas; Murray Booth, A; Xiao, Ping; Anwar H Khan, M; Percival, Carl J; Shallcross, Dudley E; Taatjes, Craig A

    2014-04-25

    Rate coefficients are directly determined for the reactions of the Criegee intermediates (CI) CH2 OO and CH3 CHOO with the two simplest carboxylic acids, formic acid (HCOOH) and acetic acid (CH3 COOH), employing two complementary techniques: multiplexed photoionization mass spectrometry and cavity-enhanced broadband ultraviolet absorption spectroscopy. The measured rate coefficients are in excess of 1×10(-10)  cm(3)  s(-1) , several orders of magnitude larger than those suggested from many previous alkene ozonolysis experiments and assumed in atmospheric modeling studies. These results suggest that the reaction with carboxylic acids is a substantially more important loss process for CIs than is presently assumed. Implementing these rate coefficients in global atmospheric models shows that reactions between CI and organic acids make a substantial contribution to removal of these acids in terrestrial equatorial areas and in other regions where high CI concentrations occur such as high northern latitudes, and implies that sources of acids in these areas are larger than previously recognized. © 2014 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

  19. Developments in Methods for Measuring the Intestinal Absorption of Nanoparticle-Bound Drugs.

    Science.gov (United States)

    Liu, Wei; Pan, Hao; Zhang, Caiyun; Zhao, Liling; Zhao, Ruixia; Zhu, Yongtao; Pan, Weisan

    2016-07-21

    With the rapid development of nanotechnology, novel drug delivery systems comprising orally administered nanoparticles (NPs) have been paid increasing attention in recent years. The bioavailability of orally administered drugs has significant influence on drug efficacy and therapeutic dosage, and it is therefore imperative that the intestinal absorption of oral NPs be investigated. This review examines the various literature on the oral absorption of polymeric NPs, and provides an overview of the intestinal absorption models that have been developed for the study of oral nanoparticles. Three major categories of models including a total of eight measurement methods are described in detail (in vitro: dialysis bag, rat gut sac, Ussing chamber, cell culture model; in situ: intestinal perfusion, intestinal loops, intestinal vascular cannulation; in vivo: the blood/urine drug concentration method), and the advantages and disadvantages of each method are contrasted and elucidated. In general, in vitro and in situ methods are relatively convenient but lack accuracy, while the in vivo method is troublesome but can provide a true reflection of drug absorption in vivo. This review summarizes the development of intestinal absorption experiments in recent years and provides a reference for the systematic study of the intestinal absorption of nanoparticle-bound drugs.

  20. Numerical study on over reading coefficient in wet steam flow measurement

    International Nuclear Information System (INIS)

    Bai Xuesong; Yuan Dewen; Yan Xiao; Peng Xingjian

    2013-01-01

    This paper investigated the flow process of wet steam in Venturi under interested conditions with CFD simulation software. The effect of pressure, mass flow rate, throat radius on over reading factor was analyzed. This paper aims to improve the wet steam over reading model and the prediction accuracy in wet steam. The results prove that the mass flow has a small effect on over reading coefficient, while the effect that throat radius has on over reading coefficient increases as the pressure rises. (authors)

  1. Airborne differential absorption lidar system for measurements of atmospheric water vapor and aerosols

    Science.gov (United States)

    Carter, Arlen F.; Allen, Robert J.; Mayo, M. Neale; Butler, Carolyn F.; Grossman, Benoist E.; Ismail, Syed; Grant, William B.; Browell, Edward V.; Higdon, Noah S.; Mayor, Shane D.; hide

    1994-01-01

    An airborne differential absorption lidar (DIAL) system has been developed at the NASA Langley Research Center for remote measurements of atmospheric water vapor (H2O) and aerosols. A solid-state alexandrite laser with a 1-pm linewidth and greater than 99.85% spectral purity was used as the on-line transmitter. Solid-state avalanche photodiode detector technology has replaced photomultiplier tubes in the receiver system, providing an average increase by a factor of 1.5-2.5 in the signal-to-noise ratio of the H2O measurement. By incorporating advanced diagnostic and data-acquisition instrumentation into other subsystems, we achieved additional improvements in system operational reliability and measurement accuracy. Laboratory spectroscopic measurements of H2O absorption-line parameters were performed to reduce the uncertainties in our knowledge of the absorption cross sections. Line-center H2O absorption cross sections were determined, with errors of 3-6%, for more than 120 lines in the 720-nm region. Flight tests of the system were conducted during 1989-1991 on the NASA Wallops Flight Facility Electra aircraft, and extensive intercomparison measurements were performed with dew-point hygrometers and H2O radiosondes. The H2O distributions measured with the DIAL system differed by less than 10% from the profiles determined with the in situ probes in a variety of atmospheric conditions.

  2. Cavity ring-down spectroscopy (CRDS) system for measuring atmospheric mercury using differential absorption

    Science.gov (United States)

    Pierce, A.; Obrist, D.; Moosmuller, H.; Moore, C.

    2012-04-01

    Atmospheric elemental mercury (Hg0) is a globally pervasive element that can be transported and deposited to remote ecosystems where it poses — particularly in its methylated form — harm to many organisms including humans. Current techniques for measurement of atmospheric Hg0 require several liters of sample air and several minutes for each analysis. Fast-response (i.e., 1 second or faster) measurements would improve our ability to understand and track chemical cycling of mercury in the atmosphere, including high frequency Hg0 fluctuations, sources and sinks, and chemical transformation processes. We present theory, design, challenges, and current results of our new prototype sensor based on cavity ring-down spectroscopy (CRDS) for fast-response measurement of Hg0 mass concentrations. CRDS is a direct absorption technique that implements path-lengths of multiple kilometers in a compact absorption cell using high-reflectivity mirrors, thereby improving sensitivity and reducing sample volume compared to conventional absorption spectroscopy. Our sensor includes a frequency-doubled, dye-laser emitting laser pulses tunable from 215 to 280 nm, pumped by a Q-switched, frequency tripled Nd:YAG laser with a pulse repetition rate of 50 Hz. We present how we successfully perform automated wavelength locking and stabilization of the laser to the peak Hg0 absorption line at 253.65 nm using an external isotopically-enriched mercury (202Hg0) cell. An emphasis of this presentation will be on the implementation of differential absorption measurement whereby measurements are alternated between the peak Hg0 absorption wavelength and a nearby wavelength "off" the absorption line. This can be achieved using a piezo electric tuning element that allows for pulse-by-pulse tuning and detuning of the laser "online" and "offline" of the Hg absorption line, and thereby allows for continuous correction of baseline extinction losses. Unexpected challenges with this approach included

  3. Electron temperature distribution measurement in Z pinch by the laser radiation absorption method

    International Nuclear Information System (INIS)

    Sarkisov, G.S.; Ehtlisher, B.

    1995-01-01

    The paper proposes a new method for measuring the temperature of internal region of Z-pinch; the method is based on laser probing of plasma and simultaneous measurements of absorption profiles and interferential run-on of probing radiation phase inside Z-pinch. It is shown that opaque pinch region which occurs laser probing experiments is related to the absorption of radiation. It is shown that laser radiation which has passed through Z-pinch features sufficiently high degree of coherence which enables interferometry of absorption region. The values of electron density and electron temperature were recovered in the experiments with Z-pinches (produced after an explosion of 20 μm aluminium wire by 50 ns pulse of current of about 250 kA for necking the pinch of ∼ 1.4 x 10 20 cm -3 and ∼ 530 eV, respectively. 11 refs., 4 figs

  4. Iodine flow rate measurement for COIL with the chemical iodine generator based on absorption spectroscopy

    Science.gov (United States)

    Zhao, Weili; Zhang, Yuelong; Zhang, Peng; Xu, Mingxiu; Jin, Yuqi; Sang, Fengting

    2015-02-01

    A dual-components absorption method based on absorption spectroscopy was described in the paper. It can easily eliminate the influence of the serious contamination and aerosol scattering on IFR measurement by utilizing the absorptions of iodine vapor and chlorine on two different wavelengths respectively. According to the character that there is no other gaseous product in the reaction besides iodine vapor, IFR in real time can be obtained by the connections of the pressure and the flow rate among chlorine remainder, iodine vapor, and the buffer gas. We used this method to measure IFR for the first time at the exit of a chemical iodine generator. The average of IFR is coincident with that calculated by chemical weighting mass.

  5. Detection of O4 absorption around 328 and 419 nm in measured atmospheric absorption spectra

    Directory of Open Access Journals (Sweden)

    J. Lampel

    2018-02-01

    Full Text Available Retrieving the column of an absorbing trace gas from spectral data requires that all absorbers in the corresponding wavelength range are sufficiently well known. This is especially important for the retrieval of weak absorbers, whose absorptions are often in the 10−4 range. Previous publications on the absorptions of the oxygen dimer O2–O2 (or short: O4 list absorption peaks at 328 and 419 nm, for which no spectrally resolved literature cross sections are available. As these absorptions potentially influence the spectral retrieval of various trace gases, such as HCHO, BrO, OClO and IO, their shape and magnitude need to be quantified. We assume that the shape of the absorption peaks at 328 and 419 nm can be approximated by their respective neighbouring absorption peaks. Using this approach we obtain estimates for the wavelength of the absorption and its magnitude. Using long-path differential optical absorption spectroscopy (LP-DOAS observations and multi-axis DOAS (MAX-DOAS observations, we estimate the peak absorption cross sections of O4 to be (1.96  ±  0.20 × 10−47 cm5 molec−2 and determine the wavelength of its maximum at 328.59  ±  0.15 nm. For the absorption at 419.13  ±  0.42 nm a peak O4 cross-section value is determined to be (5.0  ±  3.5 × 10−48 cm5 molec−2.

  6. Effects of the Absorption Behaviour of ZnO Nanoparticles on Cytotoxicity Measurements

    Directory of Open Access Journals (Sweden)

    Nigar Najim

    2014-01-01

    Full Text Available ZnO absorbs certain wavelengths of light and this behavior is more pronounced for nanoparticles of ZnO. As many toxicity measurements rely on measuring light transmission in cell lines, it is essential to determine how far this light absorption influences experimental toxicity measurements. The main objective was to study the ZnO absorption and how this influenced the cytotoxicity measurements. The cytotoxicity of differently sized ZnO nanoparticles in normal and cancer cell lines derived from lung tissue (Hs888Lu, neuron-phenotypic cells (SH-SY5Y, neuroblastoma (SH-SY5Y, human histiocytic lymphoma (U937, and lung cancer (A549 was investigated. Our results demonstrate that the presence of ZnO affected the cytotoxicity measurements due to the absorption characteristic of ZnO nanoparticles. The data revealed that the ZnO nanoparticles with an average particle size of around 85.7 nm and 190 nm showed cytotoxicity towards U937, SH-SY5Y, differentiated SH-SY5Y, and Hs888Lu cell lines. No effect on the A549 cells was observed. It was also found that the cytotoxicity of ZnO was particle size, concentration, and time dependent. These studies are the first to quantify the influence of ZnO nanoparticles on cytotoxicity assays. Corrections for absorption effects were carried out which gave an accurate estimation of the concentrations that produce the cytotoxic effects.

  7. Aerosol absorption measurement with a sinusoidal phase modulating fiber optic photo thermal interferometer

    Science.gov (United States)

    Li, Shuwang; Shao, Shiyong; Mei, Haiping; Rao, Ruizhong

    2016-10-01

    Aerosol light absorption plays an important role in the earth's atmosphere direct and semi-direct radiate forcing, simultaneously, it also has a huge influence on the visibility impairment and laser engineering application. Although various methods have been developed for measuring aerosol light absorption, huge challenge still remains in precision, accuracy and temporal resolution. The main reason is that, as a part of aerosol light extinction, aerosol light absorption always generates synchronously with aerosol light scattering, and unfortunately aerosol light scattering is much stronger in most cases. Here, a novel photo-thermal interferometry is proposed only for aerosol absorption measurement without disturbance from aerosol scattering. The photo-thermal interferometry consists of a sinusoidal phase-modulating single mode fiber-optic interferometer. The thermal dissipation, caused by aerosol energy from photo-thermal conversion when irritated by pump laser through interferometer, is detected. This approach is completely insensitive to aerosol scattering, and the single mode fiber-optic interferometer is compact, low-cost and insensitive to the polarization shading. The theory of this technique is illustrated, followed by the basic structure of the sinusoidal phase-modulating fiber-optic interferometer and demodulation algorithms. Qualitative and quantitative analysis results show that the new photo-thermal interference is a potential approach for aerosol absorption detection and environmental pollution detection.

  8. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats

    International Nuclear Information System (INIS)

    Zilversmit, D.B.; Hughes, L.B.

    1974-01-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ( 14 C or 3 H) and an intravenous dose of colloidal labeled cholesterol ( 3 H or 14 C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-h period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method. (U.S.)

  9. Estimates of repeatability coefficients and the number of the optimum measure to select superior genotypes in Annona muricata L.

    Science.gov (United States)

    Sanchéz, C F B; Alves, R S; Garcia, A D P; Teodoro, P E; Peixoto, L A; Silva, L A; Bhering, L L; Resende, M D V

    2017-09-21

    The aim of this study was to evaluate repeated measures over the years to estimate repeatability coefficient and the number of the optimum measure to select superior genotypes in Annona muricata L. The fruit production was evaluated over 16 years in 71 genotypes without an experimental design. The estimation of variance components and the prediction of the permanent phenotypic value were performed using REML/BLUP proceedings. The coefficient of determination, accuracy, and selective efficiency increased when measures increased. The coefficient of determination of 80% was reached beyond 8 crop seasons with high accuracy and selective efficiency. Thus, the evaluation of 8 crop seasons can be suitable to select superior genotypes in the A. muricata L. breeding program. Predicted selection gain had a high magnitude for fruit production indicating that it is possible to take a progressive genetic advance for this trait over cycle breeding.

  10. Measurements of the reactivity temperature coefficient during zero-power tests in the nuclear power plant Gundremmingen

    International Nuclear Information System (INIS)

    Jaag, Stefan; Grosshans, Ingo

    2008-01-01

    According to the regulatory codes during the zero-power tests before the beginning of each reactor cycle it is mandatory to demonstrate by measurements that the reactivity temperature coefficient reaches negative values before reaching the operation temperature. In the past the reactivity temperature coefficient of the fuel loading composed of uranium fuel elements with final burnup smaller 40 MWd/kg was negative at about 20 C. For modern fuel loadings with higher enriched uranium fuel elements or mixed oxide fuel elements that reach final burnup of 60 MWd/kg the reactivity temperature coefficient is negative at relatively high temperatures. This fact increases the metrological expenses for the conventional measuring method. The authors describe a modified measuring technique that allows a significant time saving.

  11. Extracting surface diffusion coefficients from batch adsorption measurement data: application of the classic Langmuir kinetics model.

    Science.gov (United States)

    Chu, Khim Hoong

    2017-11-09

    Surface diffusion coefficients may be estimated by fitting solutions of a diffusion model to batch kinetic data. For non-linear systems, a numerical solution of the diffusion model's governing equations is generally required. We report here the application of the classic Langmuir kinetics model to extract surface diffusion coefficients from batch kinetic data. The use of the Langmuir kinetics model in lieu of the conventional surface diffusion model allows derivation of an analytical expression. The parameter estimation procedure requires determining the Langmuir rate coefficient from which the pertinent surface diffusion coefficient is calculated. Surface diffusion coefficients within the 10 -9 to 10 -6  cm 2 /s range obtained by fitting the Langmuir kinetics model to experimental kinetic data taken from the literature are found to be consistent with the corresponding values obtained from the traditional surface diffusion model. The virtue of this simplified parameter estimation method is that it reduces the computational complexity as the analytical expression involves only an algebraic equation in closed form which is easily evaluated by spreadsheet computation.

  12. A mathematical approach for estimating light absorption by a crop from continuous radiation measurements and restricted absorption data

    International Nuclear Information System (INIS)

    Zanetti, P.; Delfine, S.; Alvino, A.

    1999-01-01

    A sunflower (Helianthus annuus L.) crop was grown with four different water regimes to obtain different canopy growth and light absorption capability. The incoming solar radiation was recorded by an agrometeorological field station, while the percentage absorbed by the crop was measured by a ceptometer at four times and on a quasi-daily basis over the all reproductive phases. Triangulation on these data points and cubic interpolation was used to model the radiation absorbed by the canopies over time. In order to validate this approach, the procedure was also applied to a small subset of the data. Numerical quadrature based on an adaptive recursive Simpson’s rule was used to integrate the radiation absorbed by the canopies. The numerical quadrature was applied (i) to the whole data collected, represented by a cubic two-dimensional spline interpolation function, and (ii) to the interpolated values obtained from the restricted data set. The differences between (i) and (ii) for the four water regimes varied from 3.6 to 5.2% approximately. These comparisons demonstrated the potential of a restricted data interpolation model for investigating the complex phenomena of light interception by canopies with different plant structure. (author)

  13. Femtosecond Near Edge X-ray Absorption Measurement of the VO2 Phase Transition

    International Nuclear Information System (INIS)

    Cavalleri, A.; Chong, H.H.W.; Fourmaux, S.; Glover, T.E.; Heimann, P.A; Kieffer, J.C.; Padmore, H.A.; Schoenlein, R.W.

    2004-01-01

    The authors measure the insulator-to-metal transition in VO 2 using femtosecond Near-Edge X-ray Absorption. Sliced pulses of synchrotron radiation are used to detect the photo-induced dynamics at the 516-eV Vanadium L 3 edge

  14. Cryogenic Far-IR Laser Absorptivity Measurements of the Herschel Space Observatory Telescope Mirror Coatings

    NARCIS (Netherlands)

    Fischer, J.; Klaassen, T.O.; Hovenier, J.W.; Jakob, G.; Poglitsch, A.; Sternberg, O.

    2004-01-01

    Far-infrared laser calorimetry was used to measure the absorptivity, and thus the emissivity, of aluminum-coated silicon carbide mirror samples produced during the coating qualification run of the Herschel Space Observatory telescope to be launched by the European Space Agency in 2007. The samples

  15. Study and development of an in situ acoustic absorption measurement method

    NARCIS (Netherlands)

    Tijs, E.

    2013-01-01

    Sound absorbing materials are used in many applications to attenuate unwanted noise. However, existing measurement methods can only be used on a limited number of material packages and under restricted circumstances. Since PU probes are relatively new, the possibilities they offer for (absorption)

  16. On the local plane wave methods for in situ measurement of acoustic absorption

    NARCIS (Netherlands)

    Wijnant, Ysbrand H.

    2015-01-01

    In this paper we address a series of so-called local plane wave methods (LPW) to measure acoustic absorption. As opposed to other methods, these methods do not rely on assumptions of the global sound field, like e.g. a plane wave or diffuse field, but are based on a local plane wave assumption.

  17. Theory and application of a new method for the in-situ measurement of sound absorption

    NARCIS (Netherlands)

    Kuipers, E.R.; Wijnant, Ysbrand H.; de Boer, Andries; Klemenz, M.

    2011-01-01

    In many applications of noise control engineering, knowledge about the sound-absorbing properties of acoustically reacting surfaces is essential. Being able to measure sound absorption of surfaces in-situ, i.e. at the site but also for the actual sound source, is very useful and would eliminate the

  18. The Measurement of Polymer Swelling Processes by an Interferometric Method and Evaluation of Diffusion Coefficients

    Directory of Open Access Journals (Sweden)

    Aleš Mráček

    2010-02-01

    Full Text Available The amorphous polymer film swelling in a liquid solvent below the glass transition temperature was characterized by a few kinetic parameters (especially the mutual diffusion coefficient of swelling and its mean value obtained by interference of monochromatic light in the wedge arrangement. This interferometric method allows one to determine the concentration field in the swollen surface layer and consequently to compute the concentration-dependent diffusion coefficient. A software system developed at the Department of Physics and Material Engineering at TBU in Zlin has been used for the evaluation of the main kinetic parameters of the swelling process. The software can be used for the on-line analyses of interferograms during the swelling process. The main application outputs are the computation of the concentration profile, the concentration gradient, the mutual diffusion coefficient of the swelling by the solvent and its mean value.

  19. Experimental measurement of fluid force coefficients for helical tube arrays in air cross flow

    International Nuclear Information System (INIS)

    Shen Shifang; Liu Reilan

    1993-01-01

    A helical coil steam generator is extensively used in the High Temperature Gas Cooled Reactor (HTGCR) and Sodium Cooled Reactor (SCR) nuclear power stations because of its compact structure, good heat-exchange, and small volume. The experimental model is established by the structure parameter of 200MW HTGCR. The fluid elastic instability of helical tube arrays in air cross flow is studied in this experiment, and the fluid force coefficients of helical tube arrays having the same notational direction of two adjacent layers in air cross flow are obtained. As compared to the fluid force coefficients of cylinder tube arrays, the fluid force coefficients of helical tube arrays are smaller in the low velocity area, and greater in the high velocity area. The experimental results help the study of the dynamic characteristics of helical tube arrays in air cross flow

  20. Method for measurement of relative differences in thermal expansion coefficients (LWBR development program)

    International Nuclear Information System (INIS)

    Alexander, J.E.

    1978-06-01

    The report describes a test which was conducted to determine the variation in thermal expansion coefficients of specimens from several material heats of Type 304 stainless steel. The purpose of this document is to identify the procedures, equipment, and analysis used in performing this test. From a review of the data which were used in establishing the values given for mean coefficient of thermal expansion in the 1968 ASME Boiler and Pressure Vessel Code, Section III, a +-3.3-percent maximum variation was determined for Type 304 CRES in the temperature range of interest. The results of the test reduced this variation to +-0.53 percent based on a 95/99-percent tolerance interval for the material tested. The testing equipment, procedure, and analysis are not complicated and this type of test is recommended for applications in which the variation in thermal expansion coefficients is desired for a limited number of material heats

  1. Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

    Science.gov (United States)

    Chang, Leyen S.; Strand, Christopher L.; Jeffries, Jay B.; Hanson, Ronald K.; Diskin, Glenn S.; Gaffney, Richard L.; Capriotti, Diego P.

    2011-01-01

    Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

  2. Measurement of the Diffusion Coefficient of Water in RP-3 and RP-5 Jet Fuels Using Digital Holography Interferometry

    Science.gov (United States)

    Li, Chaoyue; Feng, Shiyu; Shao, Lei; Pan, Jun; Liu, Weihua

    2018-04-01

    The diffusion coefficient of water in jet fuel was measured employing double-exposure digital holographic interferometry to clarify the diffusion process and make the aircraft fuel system safe. The experimental method and apparatus are introduced in detail, and the digital image processing program is coded in MATLAB according to the theory of the Fourier transform. At temperatures ranging from 278.15 K to 333.15 K in intervals of 5 K, the diffusion coefficient of water in RP-3 and RP-5 jet fuels ranges from 2.6967 × 10 -10 m2·s-1 to 8.7332 × 10 -10 m2·s-1 and from 2.3517 × 10 -10 m2·s-1 to 8.0099 × 10-10 m2·s-1, respectively. The relationship between the measured diffusion coefficient and temperature can be well fitted by the Arrhenius law. The diffusion coefficient of water in RP-3 jet fuel is higher than that of water in RP-5 jet fuel at the same temperature. Furthermore, the viscosities of the two jet fuels were measured and found to be expressible in the form of the Arrhenius equation. The relationship among the diffusion coefficient, viscosity and temperature is analyzed according to the classic prediction model, namely the Stokes-Einstein correlation, and this correlation is further revised via experimental data to obtain a more accurate predication result.

  3. Carbon emission coefficient measurement of the coal-to-power energy chain in China

    OpenAIRE

    Shiwei Yu; Yi-Ming Wei; Haixiang Guo; Liping Ding

    2012-01-01

    Coal-fired electricity generation has become the largest source of carbon emission in China. This study utilizes life-cycle assessment to assess the effect of carbon emissions and to calculate the coefficient of carbon emissions in coal-to-energy chains. Results show that the carbon emission coefficient of the coal-to-energy chain in China is 875 g/kW h-1, which is a relatively low level compared with that of other countries. CO2 is the main type of greenhouse gas emission and the most abunda...

  4. Emission and absorption quantum noise measurement with an on-chip resonant circuit.

    Science.gov (United States)

    Basset, J; Bouchiat, H; Deblock, R

    2010-10-15

    Using a quantum detector, a superconductor-insulator-superconductor junction, we probe separately the emission and absorption noise in the quantum regime of a superconducting resonant circuit at equilibrium. At low temperature the resonant circuit exhibits only absorption noise related to zero point fluctuations, whereas at higher temperature emission noise is also present. By coupling a Josephson junction, biased above the superconducting gap, to the same resonant circuit, we directly measure the noise power of quasiparticles tunneling through the junction at two resonance frequencies. It exhibits a strong frequency dependence, consistent with theoretical predictions.

  5. Measurement of the X-ray mass attenuation coefficients of silver in the 5-20 keV range.

    Science.gov (United States)

    Islam, M Tauhidul; Tantau, Lachlan J; Rae, Nicholas A; Barnea, Zwi; Tran, Chanh Q; Chantler, Christopher T

    2014-03-01

    The X-ray mass attenuation coefficients of silver were measured in the energy range 5-20 keV with an accuracy of 0.01-0.2% on a relative scale down to 5.3 keV, and of 0.09-1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X-ray attenuation of high-Z elements can be measured with high accuracy even at low X-ray energies (silver in the low energy range, indicating the possibility of obtaining high-accuracy X-ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X-ray extended-range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.

  6. Determination of the manning coefficient from measured bed roughness in natural channels

    Science.gov (United States)

    Limerinos, John Thomas

    1970-01-01

    This report presents the results of a study to test the hypothesis that basic values of the Manning roughness coefficient of stream channels may be related to (1) some characteristic size of the streambed particles and to (2) the distribution of particle size. These two elements involving particle size can be combined into a single element by weighting characteristic particle sizes. The investigation was confined to channels with coarse bed material to avoid the complication of bed-form roughness that is associated with alluvial channels composed of fine bed material. Fifty current-meter measurements of discharge and appropriate field surveys were made at 11 sites on California streams for the purpose of computing the roughness coefficient, n, by the Manning formula. The test sites were selected to give a wide range in average size of bed material, and the discharge measurements and surveys were made at such times as to provide data covering a suitable range in stream depth. The sites selected were relatively free of the extraneous flow-retarding effects associated with irregular channel conformation and streambank vegetation. The characteristic bed-particle sizes used in the analyses were the 16,- 50,- and 84-percentile sizes as obtained from a cumulative frequency distribution of the diameters of randomly sampled surficial bed material. Separate distributions were computed for the minimum and intermediate values of the three diameters of a particle. The minimum diameters of the streambed particles were used in the study because a particle at rest on the bed invariably has its minimum diameter in the vertical position; this diameter is, therefore, the most representative measure of roughness height. The intermediate diameter was also studied because this is the diameter most easily measurable-either by sieve analysis or by photographic techniques--and--because it is the diameter that had been used in previous studies by other investigators. No significant

  7. Application of the beta-ray absorption method to the measurement of particles in the air

    Energy Technology Data Exchange (ETDEWEB)

    Ise, Hiroaki; Nakamura, Masaru; Maeno, Tomokazu; Tanizaki, Yoshiyuki [Tokyo Metropolitan Isotope Research Center (Japan)

    1996-03-01

    With a view to facilitating the application of the micro-mass measuring technology which utilizes the beta-ray absorption method to the field of measurement of particles in the air, we have developed a multipurpose device to capture and evaluate the particles. It is applicable to a wide range of measurement of particles such as suspended particulate matters (SPM), dust falls and source particles. We have also made a study on its performance. As a result of our study on the material of the filter, which was carried out to improve the accuracy of measurement by beta-ray absorption method taking into consideration the application of such methods as the component analysis by PIXE, it was clarified that the combination of the polycarbonate membrane filter and the glass fiber filter coated with Teflon is excellent in performance. Moreover we also made a study on a simple measuring method of SPM, which will make it possible to measure the mass concentration of captured SPM even if its amount is very small, based on the data obtained by the automatic measuring device which is always monitoring one hour value of mass concentration of SPM through the beta-ray absorption method. As a result, we found that the combined method of the beta-ray absorption method the laser light scattering method and the filtration capturing/color differential method is excellent. So, we suggested a new measuring method derived from the color differential method and the sensual evaluation method. It will make it possible to measure SPM with an accuracy in the order of microgram. (author)

  8. A COMPARATIVE LOOK INTO HOW TO MEASURE THE EFFECTIVENESS OF VOCABULARY LEARNING STRATEGIES: THROUGH USING PERCENTAGES OR CORRELATION COEFFICIENTS

    Directory of Open Access Journals (Sweden)

    İsmail Hakkı ERTEN

    2008-10-01

    Full Text Available This study aims to compare the appropriateness of two statistical procedures for measuring the effectiveness of vocabulary learning strategies: percentages and correlation coefficients. To do this a group of 20 learners of English were asked to study 12 words in a written list, with their pronunciations, dictionary definitions, and example sentences. Data was collected through introspection where students were asked to verbalize their mental processes as they studied the target words. A pre-test and post-test were given to measure the task achievement. The qualitative data was transcribed verbatim and content-analysed for tokens of strategy use as well as by noting whether each use of strategies led to successful recall of the words on which they were used. To calculate the strategy effectiveness, both simple percentage calculation and correlation coefficients were employed for comparison. The findings indicated that percentage calculation can give a more realistic picture of strategy effectiveness than correlation coefficients.

  9. Easy measurement of diffusion coefficients of EGFP-tagged plasma membrane proteins using k-space Image Correlation Spectroscopy

    DEFF Research Database (Denmark)

    Christensen, Eva Arnspang; Koffman, Jennifer Skaarup; Marlar, Saw

    2014-01-01

    Lateral diffusion and compartmentalization of plasma membrane proteins are tightly regulated in cells and thus, studying these processes will reveal new insights to plasma membrane protein function and regulation. Recently, k-Space Image Correlation Spectroscopy (kICS)1 was developed to enable...... routine measurements of diffusion coefficients directly from images of fluorescently tagged plasma membrane proteins, that avoided systematic biases introduced by probe photophysics. Although the theoretical basis for the analysis is complex, the method can be implemented by nonexperts using a freely...... to the correlation function yields the diffusion coefficient. This paper provides a step-by-step guide to the image analysis and measurement of diffusion coefficients via kICS. First, a high frame rate image sequence of a fluorescently labeled plasma membrane protein is acquired using a fluorescence microscope Then...

  10. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Gonen, Korcan Aysun, E-mail: aysunbalc@yahoo.com [Department of Radiology, State Hospital, Eski Cami district, Hastane street, N:1, 59300, Tekirdag (Turkey); Simsek, Mehmet Masum, E-mail: radyoloji@haydapasanumune.gov.tr [Department of Radiology, Haydarpasa Numune Training and Research Hospital, Tibbiye street, Uskudar 34200, Istanbul (Turkey)

    2010-11-15

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC{sub IC}), ischemic penumbra (ADC{sub P}) and the nonischemic parenchymal tissue (ADC{sub N}). P values < 0.05 were accepted to be statistically significant. Results: During the between 6 and 12 h mean infarction volume calculated by DWI was 23.3 cm{sup 3} for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm{sup 3} (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm{sup 3} (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC{sub IC} and ADC{sub N} values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC{sub P} values between the groups was found to be highly significant (p < 0.001). When the differences between the ADC{sub P} and ADC{sub IC} and ADC{sub N} and ADC{sub P} were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from

  11. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    International Nuclear Information System (INIS)

    Gonen, Korcan Aysun; Simsek, Mehmet Masum

    2010-01-01

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC IC ), ischemic penumbra (ADC P ) and the nonischemic parenchymal tissue (ADC N ). P values 3 for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm 3 (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm 3 (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC IC and ADC N values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC P values between the groups was found to be highly significant (p P and ADC IC and ADC N and ADC P were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from the core and the penumbra of the infarction area will be beneficial in the estimation of the infarction prognosis and in the planning of a treatment protocol.

  12. Carbon emission coefficient measurement of the coal-to-power energy chain in China

    International Nuclear Information System (INIS)

    Yu, Shiwei; Wei, Yi-Ming; Guo, Haixiang; Ding, Liping

    2014-01-01

    Highlights: • CO 2 emissions coefficient of the coal-energy chain in China is currently at 875 g/kW h −1 . • The emission coefficient is a relatively low level compared with other countries. • CO 2 is the main type of GHG emission and the most direct emission in the chain. • A great decline of potential energy use exists in the coal mining process of China compared with other countries. - Abstract: Coal-fired electricity generation has become the largest source of carbon emission in China. This study utilizes life-cycle assessment to assess the effect of carbon emissions and to calculate the coefficient of carbon emissions in coal-to-energy chains. Results show that the carbon emission coefficient of the coal-to-energy chain in China is 875 g/kW h −1 , which is a relatively low level compared with that of other countries. CO 2 is the main type of greenhouse gas emission and is the most abundant type of direct emission. China has to reduce electrical consumption in the coal-mining process to reduce carbon emissions in coal-to-energy chains. Moreover, China has to facilitate railway-line construction to improve the proportion of railway transportation to coal transportation

  13. Novel Technique for Direct Measurement of the Plasma Diffusion Coefficient in Magnetized Plasma

    Czech Academy of Sciences Publication Activity Database

    Brotánková, Jana; Martines, E.; Adámek, Jiří; Stöckel, Jan; Popa, G.; Costin, C.; Ionita, G.; Schrittwieser, R.; Van Oost, G.

    2008-01-01

    Roč. 48, 5-7 (2008), s. 418-423 ISSN 0863-1042. [International Workshop on Electrical Probes in Magnetized Plasmas/7th./. Praha, 22.07.2007-25.07.2007] Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak * probe diagnostics * diffusion coefficient Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.250, year: 2008

  14. Comment on "A theoretical framework for quantitatively characterizing sound field diffusion based on scattering coefficient and absorption coefficient of walls" [J. Acoust. Soc. Am. 128, 1140-1148 (2010)] (L).

    Science.gov (United States)

    Omoto, Akira

    2013-01-01

    The relationship between the acoustic scattering characteristics of materials and the degree of diffusion in enclosed acoustic spaces has recently attracted considerable research attention. Hanyu [J. Acoust. Soc. Am. 128(3), 1140-1148 (2010)] introduced a theoretical framework, in which the diffusion time in an enclosure is expressed as a function of a material's average scattering coefficient. In this letter, a modification of this theory is proposed. The decay process of the sound energy through scattering is divided into discrete sub-processes, specifically, a purely scattering process, and alternating scattering and specular reflections. The behavior of each process is examined for different scattering coefficients.

  15. Inferring brown carbon content from UV aerosol absorption measurements during biomass burning season

    Science.gov (United States)

    Mok, J.; Krotkov, N. A.; Arola, A. T.; Torres, O.; Jethva, H. T.; Andrade, M.; Labow, G. J.; Eck, T. F.; Li, Z.; Dickerson, R. R.; Stenchikov, G. L.; Osipov, S.

    2015-12-01

    Measuring spectral dependence of light absorption by colored organic or "brown" carbon (BrC) is important, because of its effects on photolysis rates of ozone and surface ultraviolet (UV) radiation. Enhanced UV spectral absorption by BrC can in turn be exploited for simultaneous retrievals of BrC and black carbon (BC) column amounts in field campaigns. We present an innovative ground-based retrieval of BC and BrC volume fractions and their mass absorption efficiencies during the biomass burning season in Santa Cruz, Bolivia in September-October 2007. Our method combines retrieval of BC volume fraction using AERONET inversion in visible wavelengths with the inversion of total BC+BrC absorption (i.e., column effective imaginary refractive index, kmeas) using Diffuse/Direct irradiance measurements in UV wavelengths. First, we retrieve BrC volume fraction by fitting kmeas at 368nm using Maxwell-Garnett (MG) mixing rules assuming: (1) flat spectral dependence of kBC, (2) known value of kBrC at 368nm from laboratory absorption measurements or smoke chamber experiments, and (3) known BC volume fraction from AERONET inversion. Next, we derive kBrC in short UVB wavelengths by fitting kmeas at 305nm, 311nm, 317nm, 325nm, and 332nm using MG mixing rules and fixed volume fractions of BC and BrC. Our retrievals show larger than expected spectral dependence of kBrC in UVB wavelengths, implying reduced surface UVB irradiance and inhibited photolysis rates of surface ozone destruction. We use a one-dimensional chemical box model to show that the observed strong wavelength dependence of BrC absorption leads to inhibited photolysis of ozone to O(1D), a loss mechanism, while having little impact or even accelerating photolysis of NO2, an ozone production mechanism. Although BC only absorption in biomass burning aerosols is important for climate radiative forcing in the visible wavelengths, additional absorption by BrC is important because of its impact on surface UVB radiation

  16. Cosmological Evolution of the Universe Neutral Gas Mass Measured by Quasar Absorption Systems

    OpenAIRE

    Peroux, Celine; McMahon, Richard G.; Irwin, Mike; Storrie-Lombardi, Lisa J.

    2001-01-01

    The cosmological evolution of neutral hydrogen is an efficient way of tracing structure formation with redshift. It indicates the rate of evolution of gas into stars and hence the gas consumption and rate star formation history of the Universe. In measuring HI, quasar absorbers have proven to be an ideal tool and we use observations from a recent survey for high-redshift quasar absorption systems together with data gathered from the literature to measure the cosmological comoving mass density...

  17. Measurement of Soret coefficients in a ternary mixture of toluene-methanol-cyclohexane in convection-free environment

    Science.gov (United States)

    Mialdun, A.; Ryzhkov, I.; Khlybov, O.; Lyubimova, T.; Shevtsova, V.

    2018-01-01

    We report on the measurement of Soret (ST) coefficients in the ternary system toluene (T)-methanol (M)-cyclohexane (Ch) onboard the International Space Station in the experiment selectable optical diagnostic instrument/DCMIX2 (Diffusion Coefficients Measurement in ternary mIXtures). Nine experiments were conducted in the range of mean temperatures between 298.15 K and 306.15 K in the mixture with composition 0.62 (T)-0.31 (M)-0.07 (Ch) in mass fractions. A linear dependence of the Soret coefficients on temperature was established for the ternary mixture. It has also been found that, over considered range of mean temperatures, the Soret coefficients of toluene are small and positive, while the Soret coefficients for methanol are negative and, at least, two times larger. The present work also presents a comprehensive study of possible methodologies to process raw data from the Soret experiment in ternary mixtures. All the experiments were processed by seven different schemes and two of them were identified as the most reliable. We also investigate the error propagation and explain the reasons for the discrepancy of the results obtained by different schemes.

  18. [Measurement on gas temperature distribution by tunable diode laser absorption spectroscopy].

    Science.gov (United States)

    Li, Ning; Yan, Jian-hua; Wang, Fei; Chi, Yong; Cen, Ke-fa

    2008-08-01

    The technique of tunable diode laser absorption spectroscopy (TDLAS) can be used for gas temperature distribution measurement by scanning multiple gas absorption lines with a tunable diode laser. The fundamental of gas temperature distribution measurement by TDLAS is introduced in the present paper, and the discretization strategy of equation for gas absorption is also given here. Using constrained linear least-square fitting method, the gas temperature distribution can be calculated with the help of physical constraints under the condition of uniform gas concentration and pressure. Based on the spectral parameters of four CO absorption lines near 6330 cm(-1) from HITRAN database, the model of two-temperature distribution at 300 and 600 K with each path length of 55 cm was set up. The effects of relative measurement error and different path length constraints of temperature bins on the gas temperature distribution measurement results were simulated by constrained linear least-square fitting. The results show that the temperature distribution calculation error increases as the relative measurement error rises. A measurement error of 5% could lead to a maximum relative error of 11%, and an average relative error of 2.2% for calculation result. And the weak physical constraints of path length for temperature bins could increase the calculation result error during the process of constrained linear least-square fitting. By setting up the model of two-temperature distribution with gas cells at room temperature as the cold section and in tube furnace as the hot section, the experiment of gas temperature distribution measurement in lab was carried out. Using four absorption lines of CO near 6330 cm(-1) scanned by VCSEL diode laser, and fitting the background laser intensity without absorption by the cubic polynomial to get the baseline signal, the integrals of spectral absorbance for gas temperature distribution measurement can be calculated. The relative calculation

  19. High-spectral-resolution lidar using an iodine absorption filter for atmospheric measurements

    Science.gov (United States)

    Liu, Zhaoyan; Matsui, Ichiro; Sugimoto, Nubuo

    1999-10-01

    We develop high-spectral-resolution lidar (HSRL) using an iodine absorption filter and a narrow-band Nd:YAG laser with high-frequency-doubled output and use it for atmospheric measurements at the National Institute for Environmental Studies. The lidar system separates Doppler-broadened molecular scattering and unbroadened aerosol scattering components of the backscattered laser light, consequently providing direct measurements of these two signals. Due to stable and strong absorption at room temperature, iodine absorption filters are easy to use and they enable high rejection against aerosol scattering with a short length. The measurement principle with an error analysis and the system construction of the HSRL are described. Examples of aerosol and cloud observations made by the HSRL are also presented. The experimental results indicate that the HSRL is a powerful tool for quantitatively measuring aerosol and cloud optical properties. The use of a high-output laser gives our system the ability to provide stratospheric observations. We also present the HSRL measurements of the stratospheric temperature and backscatter profiles with better resolutions in both range and time. An example of temperature and backscatter measurements is shown for the altitude range from approximately 10 to approximately 40 km with a vertical resolution of 300 m and an integrated time of approximately 2 h.

  20. Measurement of K-conversion coefficient of the M3 transition in sup 112 In sup m

    Energy Technology Data Exchange (ETDEWEB)

    Krishna, K.R.; Sastry, D.L.; Reddy, K.V. (Andhra Univ., Visakhapatnam (India). Labs. for Nuclear Research); Chintalapudi, S.N. (Variable Energy Cyclotron Centre, Calcutta (India))

    1991-11-01

    The K-conversion coefficient of the 155 keV (M3) isomeric transition in the decay of {sup 112}In was measured using the normalized peak to gamma method. The {alpha}{sub K} value is found to be 4.82{+-}0.29 in agreement with the theoretical value of 5.12. (author).

  1. Permeability and Diffusion Coefficients of Single Methyl Lactate Enantiomers in Nafion® and Cellophane Membranes Measured in Diffusion Cell.

    Czech Academy of Sciences Publication Activity Database

    Hovorka, Š.; Randová, A.; Borbášová, T.; Sysel, P.; Vychodilová, Hana; Červenková Šťastná, Lucie; Brožová, Libuše; Žitka, Jan; Storch, Jan; Kačírková, Marie; Drašar, P.; Izák, Pavel

    2016-01-01

    Roč. 158, JAN 28 (2016), s. 322-332 ISSN 1383-5866 R&D Projects: GA ČR(CZ) GAP106/12/0569 Institutional support: RVO:67985858 ; RVO:61389013 Keywords : diffusion coefficient measurement * permeability * nafion * cellophane * chirality of polymer membrane Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  2. Accurate measurement of the piezoelectric coefficient of thin films by eliminating the substrate bending effect using spatial scanning laser vibrometry

    International Nuclear Information System (INIS)

    Leighton, Glenn J T; Huang, Zhaorong

    2010-01-01

    One of the major difficulties in measuring the piezoelectric coefficient d 33,f for thin films is the elimination of the contribution from substrate bending. We show by theoretical analysis and experimental measurements that by bonding thin film piezoelectric samples to a substantial holder, the substrate bending can be minimized to a negligible level. Once the substrate bending can be effectively eliminated, single-beam laser scanning vibrometry can be used to measure the precise strain distribution of a piezoelectric thin film under converse actuation. A significant strain increase toward the inside edge of the top electrode (assuming a fully covered bottom electrode) and a corresponding strain peak in the opposite direction just outside the electrode edge were observed. These peaks were found to increase with the increasing Poisson's ratio and transverse piezoelectric coefficient of the piezoelectric thin film. This is due to the non-continuity of the electric field at the edge of the top electrode, which leads to the concentration of shear stress and electric field in the vicinity of the electrode edge. The measured d 33,f was found to depend not only on the material properties such as the electromechanical coefficients of the piezoelectric thin films and elastic coefficients of the thin film and the substrate, but also on the geometry factors such as the thickness of the piezoelectric films, the dimensions of the electrode, and also the thickness of the substrate

  3. Measurement of the thermal conductivity and heat transfer coefficient of a binary bed of beryllium pebbles

    Energy Technology Data Exchange (ETDEWEB)

    Donne, M.D.; Piazza, G. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Neutronenphysik und Reaktortechnik; Goraieb, A.; Sordon, G.

    1998-01-01

    The four ITER partners propose to use binary beryllium pebble bed as neutron multiplier. Recently this solution has been adopted for the ITER blanket as well. In order to study the heat transfer in the blanket the effective thermal conductivity and the wall heat transfer coefficient of the bed have to be known. Therefore at Forschungszentrum Karlsruhe heat transfer experiments have been performed with a binary bed of beryllium pebbles and the results have been correlated expressing thermal conductivity and wall heat transfer coefficients as a function of temperature in the bed and of the difference between the thermal expansion of the bed and of that of the confinement walls. The comparison of the obtained correlations with the data available from the literature show a quite good agreement. (author)

  4. Methane optical density measurements with an integrated path differential absorption lidar from an airborne platform

    Science.gov (United States)

    Riris, Haris; Numata, Kenji; Wu, Stewart; Gonzalez, Brayler; Rodriguez, Michael; Scott, Stan; Kawa, Stephan; Mao, Jianping

    2017-07-01

    We report on an airborne demonstration of atmospheric methane (CH4) measurements with an integrated path differential absorption lidar using an optical parametric amplifier and optical parametric oscillator laser transmitter and sensitive avalanche photodiode detector. The lidar measures the atmospheric CH4 absorption at multiple, discrete wavelengths near 1650.96 nm. The instrument was deployed in the fall of 2015, aboard NASA's DC-8 airborne laboratory along with an in situ spectrometer and measured CH4 over a wide range of surfaces and atmospheric conditions from altitudes of 2 to 13 km. We will show the results from our flights, compare the performance of the two laser transmitters, and identify areas of improvement for the lidar.

  5. Methane optical density measurements with an integrated path differential absorption lidar from an airborne platform.

    Science.gov (United States)

    Riris, Haris; Numata, Kenji; Wu, Stewart; Gonzalez, Brayler; Rodriguez, Michael; Scott, Stan; Kawa, Stephan; Mao, Jianping

    2017-07-01

    We report on an airborne demonstration of atmospheric methane (CH 4 ) measurements with an Integrated Path Differential Absorption (IPDA) lidar using an optical parametric amplifier (OPA) and optical parametric oscillator (OPO) laser transmitter and sensitive avalanche photodiode detector. The lidar measures the atmospheric CH 4 absorption at multiple, discrete wavelengths near 1650.96 nm. The instrument was deployed in the fall of 2015, aboard NASA's DC-8 airborne laboratory along with an in-situ spectrometer and measured CH 4 over a wide range of surfaces and atmospheric conditions from altitudes of 2 km to 13 km. In this paper, we will show the results from our flights, compare the performance of the two laser transmitters, and identify areas of improvement for the lidar.

  6. Measurement of He neutral temperature in detached plasmas using laser absorption spectroscopy

    Science.gov (United States)

    Aramaki, M.; Tsujihara, T.; Kajita, S.; Tanaka, H.; Ohno, N.

    2018-01-01

    The reduction of the heat load onto plasma-facing components by plasma detachment is an inevitable scheme in future nuclear fusion reactors. Since the control of the plasma and neutral temperatures is a key issue to the detached plasma generation, we have developed a laser absorption spectroscopy system for the metastable helium temperature measurements and used together with a previously developed laser Thomson scattering system for the electron temperature and density measurements. The thermal relaxation process between the neutral and the electron in the detached plasma generated in the linear plasma device, NAGDIS-II was studied. It is shown that the electron temperature gets close to the neutral temperature by increasing the electron density. On the other hand, the pressure dependence of electron and neutral temperatures shows the cooling effect by the neutrals. The possibility of the plasma fluctuation measurement using the fluctuation in the absorption signal is also shown.

  7. Resonant tube for measurement of sound absorption in gases at low frequency/pressure ratios

    Science.gov (United States)

    Zuckerwar, A. J.; Griffin, W. A.

    1980-01-01

    The paper describes a resonant tube for measuring sound absorption in gases, with specific emphasis on the vibrational relaxation peak of N2, over a range of frequency/pressure ratios from 0.1 to 2500 Hz/atm. The experimental background losses measured in argon agree with the theoretical wall losses except at few isolated frequencies. Rigid cavity terminations, external excitation, and a differential technique of background evaluation were used to minimize spurious contributions to the background losses. Room temperature measurements of sound absorption in binary mixtures of N2-CO2 in which both components are excitable resulted in the maximum frequency/pressure ratio in Hz/atm of 0.063 + 123m for the N2 vibrational relaxation peak, where m is mole percent of added CO2; the maximum ratio for the CO2 peak was 34,500 268m where m is mole percent of added N2.

  8. Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

    Science.gov (United States)

    Rattanakijsuntorn, Komsan; Penkova, Anita; Sadha, Satwindar S.

    2018-01-01

    In early studies, the ‘contour method’ for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).

  9. Analyses of Spring Barley Evapotranspiration Rates Based on Gradient Measurements and Dual Crop Coefficient Model

    Czech Academy of Sciences Publication Activity Database

    Pozníková, Gabriela; Fischer, Milan; Pohanková, Eva; Trnka, Miroslav

    2014-01-01

    Roč. 62, č. 5 (2014), s. 1079-1086 ISSN 1211-8516 R&D Projects: GA MŠk LH12037; GA MŠk(CZ) EE2.3.20.0248 Institutional support: RVO:67179843 Keywords : evapotranspiration * dual crop coefficient model * Bowen ratio/energy balance method * transpiration * soil evaporation * spring barley Subject RIV: EH - Ecology, Behaviour OBOR OECD: Environmental sciences (social aspects to be 5.7)

  10. Determination of reactivity coefficients from measurable effects of small external perturbations using a bank of Kalman filters

    International Nuclear Information System (INIS)

    Racz, A.

    1990-12-01

    The goal of this paper is to present a method for the determination of reactivity coefficients in a nuclear power reactor in operation. A method based on Kalman filtering technique and the Magill-Bogler test is proposed for the determination of reactivity coefficients from measured effects of small external perturbation introduced into a steady-state power reactor. Numerical experiments are presented to justify the procedure. A realistic problem is considered: the calculation of the control rod worth. Finally a possible way is given to check the goodness of the estimation. (author) 16 refs.; 4 figs

  11. Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

    Science.gov (United States)

    Browell, Edward V.; Ismail, Syed; Grossmann, Benoist E.

    1991-01-01

    Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

  12. Measurement as absorption of Feynman trajectories: Collapse of the wave function can be avoided

    International Nuclear Information System (INIS)

    Marchewka, A.; Schuss, Z.

    2002-01-01

    We define a measuring device (detector) of the coordinate of quantum particle as an absorbing wall that cuts off the particle's wave function. The wave function in the presence of such a detector vanishes on the detector. The trace the absorbed particles leave on the detector is identified as the absorption current density on the detector. This density is calculated from the solution of Schroedinger's equation with a reflecting boundary at the detector. This current density is not the usual Schroedinger current density. We define the probability distribution of the time of arrival to a detector in terms of the absorption current density. We define coordinate measurement by an absorbing wall in terms of four postulates. In the resulting theory the quantum-mechanical collapse of the wave function is replaced with the usual collapse of the probability distribution after observation. Two measurement experiments are proposed to measure time of arrival and the probability density function of a freely propagating two-dimensional Gaussian packet from the measurement of the absorption current on two planes

  13. Measurement of sound power and absorption in reverberation chambers using energy density.

    Science.gov (United States)

    Nutter, David B; Leishman, Timothy W; Sommerfeldt, Scott D; Blotter, Jonathan D

    2007-05-01

    Reverberation chamber measurements typically rely upon spatially averaged squared pressure for the calculation of sound absorption, sound power, and other acoustic values. While a reverberation chamber can provide an approximately diffuse sound field, variations in sound pressure consistently produce uncertainty in measurement results. This paper explores the benefits of using total energy density or squared particle velocity magnitude (kinetic energy density) instead of squared pressure (potential energy density) for sound absorption and sound power measurements. The approaches are based on methods outlined in current ISO standards. The standards require a sufficient number of source-receiver locations to obtain suitable measurement results. The total and kinetic energy densities exhibit greater spatial uniformity at most frequencies than potential energy density, thus requiring fewer source-receiver positions to produce effective results. Because the total energy density is typically the most uniform of the three quantities at low frequencies, its use could also impact the usable low-frequency ranges of reverberation chambers. In order to employ total and kinetic energy densities for sound absorption measurements, relevant energy-based impulse responses were developed as part of the work for the assessment of sound field decays.

  14. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Science.gov (United States)

    Conti, C. C.; Anjos, M. J.; Salgado, C. M.

    2014-09-01

    X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br.

  15. Simulation study on the measurements of diffusion coefficients in solid materials by short-lived radiotracer beams

    CERN Document Server

    Jeong, S C; Kawakami, H

    2003-01-01

    We have examined, by a computer simulation, an on-line measurement of diffusion coefficients by using a short-lived alpha particle emitter, sup 8 Li (half life of 0.84s), as a radiotracer. The energy spectra of alpha particles emitted from diffusing sup 8 Li primarily implanted in the sample of LiAl ar simulated as a measure of the diffusion of sup 8 Li in the sample. As a possible time sequence for the measurement, a time cycle of 6s, i.e. the implantation of sup 8 Li for 1.5s and subsequent diffusion for 4.5s, is supposed. The sample is primarily set on a given temperature for the measurement. The time-dependent yields of alpha particles during the time cycle reveal the possibility to measure the diffusion coefficient with an accuracy of 10% if larger than 1 x 10 sup - sup 9 cm sup 2 /s, by the comparison with the experimental spectra measured at the temperature, i.e. at a certain diffusion coefficient. (author)

  16. Measured Wavelength-Dependent Absorption Enhancement of Internally Mixed Black Carbon with Absorbing and Nonabsorbing Materials.

    Science.gov (United States)

    You, Rian; Radney, James G; Zachariah, Michael R; Zangmeister, Christopher D

    2016-08-02

    Optical absorption spectra of laboratory generated aerosols consisting of black carbon (BC) internally mixed with nonabsorbing materials (ammonium sulfate, AS, and sodium chloride, NaCl) and BC with a weakly absorbing brown carbon surrogate derived from humic acid (HA) were measured across the visible to near-IR (550 to 840 nm). Spectra were measured in situ using a photoacoustic spectrometer and step-scanning a supercontinuum laser source with a tunable wavelength and bandwidth filter. BC had a mass-specific absorption cross section (MAC) of 7.89 ± 0.25 m(2) g(-1) at λ = 550 nm and an absorption Ångström exponent (AAE) of 1.03 ± 0.09 (2σ). For internally mixed BC, the ratio of BC mass to the total mass of the mixture was chosen as 0.13 to mimic particles observed in the terrestrial atmosphere. The manner in which BC mixed with each material was determined from transmission electron microscopy (TEM). AS/BC and HA/BC particles were fully internally mixed, and the BC was both internally and externally mixed for NaCl/BC particles. The AS/BC, NaCl/BC, and HA/BC particles had AAEs of 1.43 ± 0.05, 1.34 ± 0.06, and 1.91 ± 0.05, respectively. The observed absorption enhancement of mixed BC relative to the pure BC was wavelength dependent for AS/BC and decreased from 1.5 at λ = 550 nm with increasing wavelength while the NaCl/BC enhancement was essentially wavelength independent. For HA/BC, the enhancement ranged from 2 to 3 and was strongly wavelength dependent. Removal of the HA absorption contribution to enhancement revealed that the enhancement was ≈1.5 and independent of wavelength.

  17. Quenching of Einstein-coefficients by photons

    International Nuclear Information System (INIS)

    Aumayr, F.; Lee, W.; Skinner, C.H.; Suckewer, S.

    1991-03-01

    Experimental evidence is presented for the change of Einstein's A- coefficients for spontaneous transitions from the upper laser level of argon ion laser discharge due to the presence of the high- intensity laser flux. To demonstrate that this quenching effect cannot be attributed to a reduction in self-absorption of the strong spontaneous emission line, absorption and line profile measurements have been performed. Computer modelling of the reduction of self absorption due to Rabi splitting also indicated that this effect is too small to explain the observed quenching of spontaneous line emissions. 13 refs., 11 figs

  18. High-resolution absorption measurements of NH3 at high temperatures: 2100–5500 cm−1

    International Nuclear Information System (INIS)

    Barton, Emma J.; Yurchenko, Sergei N.; Tennyson, Jonathan; Clausen, Sønnik; Fateev, Alexander

    2017-01-01

    High-resolution absorption spectra of NH 3 in the region 2100–5500 cm −1 at 1027 °C and approximately atmospheric pressure (1045±3 mbar) are measured. An NH 3 concentration of 10% in volume fraction is used in the measurements. Spectra are recorded in a high-temperature gas-flow cell using a Fourier Transform Infrared (FTIR) spectrometer at a nominal resolution of 0.09 cm −1 . The spectra are analysed by comparison to a variational line list, BYTe, and experimental energy levels determined using the MARVEL procedure. 2308 lines have been assigned to 45 different bands, of which 1755 and 15 have been assigned or observed for the first time in this work. - Highlights: • Absorption spectrum of ammonia recorded at 1300 K. • 2038 line assignments, 1755 newly assigned. • 15 bands observed for the first time.

  19. Improved multi-element measurement of absorption via the fecal monitoring technique

    International Nuclear Information System (INIS)

    Gibson, R.S.; Gibson, I.L.; Weber, C.E.; Atkinson, S.A.

    1986-01-01

    The fecal monitoring technique for measuring the absorption of Mn, Se and Fe was studied in eight piglets using high resolution gamma spectrometry. Four day old piglets were fed a complete liquid diet for five days prior to the administration of an isotope dose ( 75 Se, 54 Mn, 59 Fe) equilibrated with the milk feeding. 51 CrCl 3 was used as a fecal marker. Subsequently stool and urine samples were collected daily for 15-21 days. Following counting, the % fecal excretion of the administered dose was calculated. As 0 to 33% of the administered 51 CrCl 3 was absorbed this fecal marker is inappropriate for piglets. Results indicate that endogenous excretion for each of the isotopes was not constant but decreased exponentially with time. An improved method for calculating the endogenous excretion was therefore developed. This method is based on the pattern of endogenous excretion in comparable piglets injected intravenously with the same isotopes, and on the level of endogenous excretion in the orally fed animals in the post-absorptive phase of excretion. These findings have important implications for the estimation of endogenous excretion in future fecal monitoring absorption studies. Previous results using the latter technique have frequently underestimated true absorption

  20. Optical Measurement of Radiocarbon below Unity Fraction Modern by Linear Absorption Spectroscopy.

    Science.gov (United States)

    Fleisher, Adam J; Long, David A; Liu, Qingnan; Gameson, Lyn; Hodges, Joseph T

    2017-09-21

    High-precision measurements of radiocarbon ( 14 C) near or below a fraction modern 14 C of 1 (F 14 C ≤ 1) are challenging and costly. An accurate, ultrasensitive linear absorption approach to detecting 14 C would provide a simple and robust benchtop alternative to off-site accelerator mass spectrometry facilities. Here we report the quantitative measurement of 14 C in gas-phase samples of CO 2 with F 14 C radiocarbon measurement science including the study of biofuels and bioplastics, illicitly traded specimens, bomb dating, and atmospheric transport.