  1. An absolute dose determination of helical tomotherapy accelerator, TomoTherapy High-Art II

    International Nuclear Information System (INIS)

    Bailat, Claude J.; Buchillier, Thierry; Pachoud, Marc; Moeckli, Raphaeel; Bochud, Francois O.

    2009-01-01

    Purpose: A helical tomotherapy accelerator presents a dosimetric challenge because, to this day, there is no internationally accepted protocol for the determination of the absolute dose. Because of this reality, we investigated the different alternatives for characterizing and measuring the absolute dose of such an accelerator. We tested several dosimetric techniques with various metrological traceabilities as well as using a number of phantoms in static and helical modes. Methods: Firstly, the relationship between the reading of ionization chambers and the absorbed dose is dependent on the beam quality value of the photon beam. For high energy photons, the beam quality is specified by the tissue phantom ratio (TPR 20,10 ) and it is therefore necessary to know the TPR 20,10 to calculate the dose delivered by a given accelerator. This parameter is obtained through the ratio of the absorbed dose at 20 and 10 cm depths in water and was measured in the particular conditions of the tomotherapy accelerator. Afterward, measurements were performed using the ionization chamber (model A1SL) delivered as a reference instrument by the vendor. This chamber is traceable in absorbed dose to water in a Co-60 beam to a water calorimeter of the American metrology institute (NIST). Similarly, in Switzerland, each radiotherapy department is directly traceable to the Swiss metrology institute (METAS) in absorbed dose to water based on a water calorimeter. For our research, this traceability was obtained by using an ionization chamber traceable to METAS (model NE 2611A), which is the secondary standard of our institute. Furthermore, in order to have another fully independent measurement method, we determined the dose using alanine dosimeters provided by and traceable to the British metrology institute (NPL); they are calibrated in absorbed dose to water using a graphite calorimeter. And finally, we wanted to take into account the type of chamber routinely used in clinical practice and

  2. SU-F-T-492: The Impact of Water Temperature On Absolute Dose Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Islam, N [State University of New York at Buffalo, Buffalo, NY (United States); Podgorsak, M [State University of New York at Buffalo, Buffalo, NY (United States); Roswell Park Cancer Institute, Buffalo, NY (United States)

    2016-06-15

    Purpose: The Task Group 51 (TG 51) protocol prescribes that dose calibration of photon beams be done by irradiating an ionization chamber in a water tank at pre-defined depths. Methodologies are provided to account for variations in measurement conditions by applying correction factors. However, the protocol does not completely account for the impact of water temperature. It is well established that water temperature will influence the density of air in the ion chamber collecting volume. Water temperature, however, will also influence the size of the collecting volume via thermal expansion of the cavity wall and the density of the water in the tank. In this work the overall effect of water temperature on absolute dosimetry has been investigated. Methods: Dose measurements were made using a Farmer-type ion chamber for 6 and 23 MV photon beams with water temperatures ranging from 10 to 40°C. A reference ion chamber was used to account for fluctuations in beam output between successive measurements. Results: For the same beam output, the dose determined using TG 51 was dependent on the temperature of the water in the tank. A linear regression of the data suggests that the dependence is statistically significant with p-values of the slope equal to 0.003 and 0.01 for 6 and 23 MV beams, respectively. For a 10 degree increase in water phantom temperature, the absolute dose determined with TG 51 increased by 0.27% and 0.31% for 6 and 23 MV beams, respectively. Conclusion: There is a measurable effect of water temperature on absolute dose calibration. To account for this effect, a reference temperature can be defined and a correction factor applied to account for deviations from this reference temperature during beam calibration. Such a factor is expected to be of similar magnitude to most of the existing TG 51 correction factors.

  3. SU-F-T-492: The Impact of Water Temperature On Absolute Dose Calibration

    International Nuclear Information System (INIS)

    Islam, N; Podgorsak, M

    2016-01-01

    Purpose: The Task Group 51 (TG 51) protocol prescribes that dose calibration of photon beams be done by irradiating an ionization chamber in a water tank at pre-defined depths. Methodologies are provided to account for variations in measurement conditions by applying correction factors. However, the protocol does not completely account for the impact of water temperature. It is well established that water temperature will influence the density of air in the ion chamber collecting volume. Water temperature, however, will also influence the size of the collecting volume via thermal expansion of the cavity wall and the density of the water in the tank. In this work the overall effect of water temperature on absolute dosimetry has been investigated. Methods: Dose measurements were made using a Farmer-type ion chamber for 6 and 23 MV photon beams with water temperatures ranging from 10 to 40°C. A reference ion chamber was used to account for fluctuations in beam output between successive measurements. Results: For the same beam output, the dose determined using TG 51 was dependent on the temperature of the water in the tank. A linear regression of the data suggests that the dependence is statistically significant with p-values of the slope equal to 0.003 and 0.01 for 6 and 23 MV beams, respectively. For a 10 degree increase in water phantom temperature, the absolute dose determined with TG 51 increased by 0.27% and 0.31% for 6 and 23 MV beams, respectively. Conclusion: There is a measurable effect of water temperature on absolute dose calibration. To account for this effect, a reference temperature can be defined and a correction factor applied to account for deviations from this reference temperature during beam calibration. Such a factor is expected to be of similar magnitude to most of the existing TG 51 correction factors.

  4. Absolute dose measurement Gafchromic R EBT2 movies. Case Study of Kaposis sarcoma

    International Nuclear Information System (INIS)

    Pereira, L.; Moral, F. del; Meilan, E.; Azevedo Gomes, J. C. de; Tejeiro Garcia, A. G.; Andrade Alvarez, B.; Vazquez, J.; Nieto, I.; Medal, D.; Lopez Medina, A.; Francisco, S.; Salgado, M.; Munoz, V.

    2011-01-01

    Because of its high spatial resolution, low energy dependence and good response over a wide energy range, EBT2 Gafchromic films are widely used in many applications in radiotherapy for measuring relative dose. Despite being the most common use can be used to measure absolute dose. This text is an example of using films as EBT2 for in vivo absolute dose in a Kaposis sarcoma.

  5. Use of a concise prescription for specifying absolute dose distribution in external beam radiation therapy

    International Nuclear Information System (INIS)

    Viggers, D.A.; Shalev, S.

    1989-01-01

    Radiation therapy dose distributions are usually calculated relative to some normalization point to which a prescribed dose in grays is to be delivered. Often the radiation therapist requests that the prescribed dose be delivered to some other point(s), such as the 90% isodose. Therefore the prescribed dose is not well defined. Furthermore, this procedure leaves the shape of the dose distribution unspecified. The authors have used a dose prescription specifying the volumes of target and nontarget tissue that must lie within dose limits stated in grays. These dose-volume limits determine the magnitude and shape of the dose distribution. The prescription is well defined while allowing the absolute dose at a chosen point to be adjusted so that the dose distribution satisfies the prescription

  6. Absolute and relative dose measurements with Gafchromic trade mark sign EBT film for high energy electron beams with different doses per pulse

    International Nuclear Information System (INIS)

    Fiandra, Christian; Ragona, Riccardo; Ricardi, Umberto; Anglesio, Silvia; Giglioli, Francesca Romana

    2008-01-01

    The authors have evaluated the accuracy, in absolute and relative dose measurements, of the Gafchromic trade mark sign EBT film in pulsed high-energy electron beams. Typically, the electron beams used in radiotherapy have a dose-per-pulse value of less than 0.1 mGy/pulse. However, very high dose-per-pulse electron beams are employed in certain linear accelerators dedicated to intraoperatory radiation therapy (IORT). In this study, the absorbed dose measurements with Gafchromic trade mark sign EBT in both low (less than 0.3 mGy per pulse) and high (30 and 70 mGy per pulse) dose-per-pulse electron beams were compared with ferrous sulfate chemical Fricke dosimetry (operated by the Italian Primary Standard Dosimetry Laboratory), a method independent of the dose per pulse. A summary of Gafchromic trade mark sign EBT in relative and absolute beam output determination is reported. This study demonstrates the independence of Gafchromic trade mark sign EBT absorption as a function of dose per pulse at different dose levels. A good agreement (within 3%) was found with Fricke dosimeters for plane-base IORT applicators. Comparison with a diode detector is presented for relative dose measurements, showing acceptable agreement both in the steep dose falloff zone and in the homogeneous dose region. This work also provides experimental values for recombination correction factor (K sat ) of a Roos (plane parallel) ionization chamber calculated on the basis of theoretical models for charge recombination.

  7. Regional and site-specific absolute humidity data for use in tritium dose calculations

    International Nuclear Information System (INIS)

    Etnier, E.L.

    1980-01-01

    Due to the potential variability in average absolute humidity over the continental U.S., and the dependence of atmospheric 3 H specific activity on absolute humidity, availability of regional absolute humidity data is of value in estimating the radiological significance of 3 H releases. Most climatological data are in the form of relative humidity, which must be converted to absolute humidity for dose calculations. Absolute humidity was calculated for 218 points across the U.S., using the 1977 annual summary of U.S. Climatological Data, and is given in a table. Mean regional values are shown on a map. (author)

  8. Absolute determination of the deuterium content of heavy water, measurement of absolute density

    International Nuclear Information System (INIS)

    Ceccaldi, M.; Riedinger, M.; Menache, M.

    1975-01-01

    The absolute density of two heavy water samples rich in deuterium (with a grade higher than 99.9%) was determined with the hydrostatic method. The exact isotopic composition of this water (hydrogen and oxygen isotopes) was very carefully studied. A theoretical estimate enabled us to get the absolute density value of isotopically pure D 2 16 O. This value was found to be 1104.750 kg.m -3 at t 68 =22.3 0 C and under the pressure of one atmosphere. (orig.) [de

  9. Absolute and relative dose-surface and dose-volume histograms of the bladder: which one is the most representative for the actual treatment?

    International Nuclear Information System (INIS)

    Hoogeman, Mischa S; Peeters, Stephanie T H; Bois, Josien de; Lebesque, Joos V

    2005-01-01

    The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment

  10. Verification of the absorbed dose values determined with plane parallel ionization chambers in therapeutic electron beams using ferrous sulfate dosimetry

    International Nuclear Information System (INIS)

    Plaetsen, A. van der; Thierens, H.; Palmans, H.

    2000-01-01

    Absolute and relative dosimetry measurements in clinical electron beams using different detectors were performed at a Philips SL18 accelerator. For absolute dosimetry, ionization chamber measurements with the PTW Markus and PTW Roos plane parallel chambers were performed in water following the recommendations of the TRS-381 Code of Practice, using different options for chamber calibration. The dose results obtained with these ionization chambers using the electron beam calibration method were compared with the dose response of the ferrous sulphate (Fricke) chemical dosimeter. The influence of the choice of detector type on the determination of physical quantities necessary for absolute dose determination was investigated and discussed. Results for d max , R 50 and R p were in agreement within statistical uncertainties when using a diode, diamond or plane parallel chamber. The effective point of measurement for the Markus chamber is found to be shifted 0.5 mm from the front surface of the cavity. Fluence correction factors, h m , for dose determination in electron beams using a PMMA phantom were determined experimentally for both plane parallel chamber types. (author)

  11. System for determining absorbed dose and its distribution for high-energy electron radiation

    International Nuclear Information System (INIS)

    Hegewald, H.; Wulff, W.

    1977-01-01

    Taking into account the polarization effect, the dose determination for high-energy electron radiation from particle accelerators depends on the knowledge of the energy dependence of the mass stopping power. Results obtained with thermoluminescent dosemeters agree with theoretical values. For absorbed dose measurements the primary energy of electron radiation has been determined by nuclear photoreactions, and the calculation of the absorbed dose from charge measurements by means of the mass stopping power is described. Thus the calibration of ionization chambers for high-energy electron radiation by absolute measurements with the Faraday cage and chemical dosemeters has become possible. (author)

  12. Single- and multiple-dose pharmacokinetics and absolute bioavailability of tedizolid.

    Science.gov (United States)

    Flanagan, Shawn; Fang, Edward; Muñoz, Kelly A; Minassian, Sonia L; Prokocimer, Philippe G

    2014-09-01

    Tedizolid phosphate is a novel antibacterial under investigation for the treatment of gram-positive infections. This study was conducted to assess the pharmacokinetics, safety, and tolerability of intravenous tedizolid phosphate as well as the oral bioavailability of tedizolid phosphate. Double-blind, single-ascending dose, multiple-dose pharmacokinetics study, as well as tolerability and open-label crossover studies. Single center in the United States (Covance Clinical Research Unit, Madison, WI) between September 2009 and January 2010. Ninety healthy volunteers. Single intravenous (IV) doses of tedizolid phosphate 50 mg (lead-in) and 100-400 mg. Single oral and IV dose of tedizolid phosphate 200 mg in crossover fashion. Multiple IV doses of tedizolid phosphate 200 and 300 mg for up to 7 days. A dose-dependent increase was observed in the maximum plasma concentration (1.2-5.1 μg/ml) and the area under the concentration-time curve (17.4-58.7 μg × hr/ml) of tedizolid (the microbiologically active moiety of tedizolid phosphate) after single IV doses of tedizolid phosphate 100-400 mg. Administration of IV tedizolid phosphate 200 mg once/day for 7 days resulted in minimal (28%) tedizolid accumulation. The absolute oral bioavailability of tedizolid after a single 200-mg dose of tedizolid phosphate was 91%; pharmacokinetic parameters of tedizolid were similar with oral and IV administration. Treatment-related adverse events occurred in 41% of subjects. Most adverse events were related to infusion site and became more frequent with multiple dosing. In an additional 3-day tolerability study, IV tedizolid phosphate 200 mg and placebo were similarly tolerated, based on visual infusion phlebitis scores. These results from a population of healthy volunteers support once/day dosing of tedizolid phosphate 200 mg with both the oral and IV formulations, without the need for dose adjustment when switching administration routes. © 2014 Cubist Pharmaceuticals. Pharmacotherapy

  13. Studies of absorbed dose determinations and spatial dose distributions for high energy proton beams

    International Nuclear Information System (INIS)

    Hiraoka, Takeshi

    1982-01-01

    Absolute dose determinations were made with three types of ionization chamber and a Faraday cup. Methane based tissue equivalent (TE) gas, nitrogen, carbon dioxide, air were used as an ionizing gas with flow rate of 10 ml per minute. Measurements were made at the entrance position of unmodulated beams and for a beam of a spread out Bragg peak at a depth of 17.3 mm in water. For both positions, the mean value of dose determined by the ionization chambers was 0.993 +- 0.014 cGy for which the value of TE gas was taken as unity. The agreement between the doses estimated by the ionization chambers and the Faraday cup was within 5%. Total uncertainty estimated in the ionization chamber and the Faraday cup determinations is 6 and 4%, respectively. Common sources of error in calculating the dose from ionization chamber measurements are depend on the factors of ion recombination, W value, and mass stopping power ratio. These factors were studied by both experimentally and theoretically. The observed values for the factors show a good agreement to the predicted one. Proton beam dosimetry intercomparison between Japan and the United States was held. Good agreement was obtained with standard deviation of 1.6%. The value of the TE calorimeter is close to the mean value of all. In the proton spot scanning system, lateral dose distributions at any depth for one spot beam can be simulated by the Gaussian distribution. From the Gaussian distributions and the central axis depth doses for one spot beam, it is easy to calculate isodose distributions in the desired field by superposition of dose distribution for one spot beam. Calculated and observed isodose curves were agreed within 1 mm at any dose levels. (J.P.N.)

  14. On determining absolute entropy without quantum theory or the third law of thermodynamics

    Science.gov (United States)

    Steane, Andrew M.

    2016-04-01

    We employ classical thermodynamics to gain information about absolute entropy, without recourse to statistical methods, quantum mechanics or the third law of thermodynamics. The Gibbs-Duhem equation yields various simple methods to determine the absolute entropy of a fluid. We also study the entropy of an ideal gas and the ionization of a plasma in thermal equilibrium. A single measurement of the degree of ionization can be used to determine an unknown constant in the entropy equation, and thus determine the absolute entropy of a gas. It follows from all these examples that the value of entropy at absolute zero temperature does not need to be assigned by postulate, but can be deduced empirically.

  15. 3D measurement of absolute radiation dose in grid therapy

    International Nuclear Information System (INIS)

    Trapp, J V; Warrington, A P; Partridge, M; Philps, A; Leach, M O; Webb, S

    2004-01-01

    Spatially fractionated radiotherapy through a grid is a concept which has a long history and was routinely used in orthovoltage radiation therapy in the middle of last century to minimize damage to the skin and subcutaneous tissue. With the advent of megavoltage radiotherapy and its skin sparing effects the use of grids in radiotherapy declined in the 1970s. However there has recently been a revival of the technique for use in palliative treatments with a single fraction of 10 to 20 Gy. In this work the absolute 3D dose distribution in a grid irradiation is measured for photons using a combination of film and gel dosimetry

  16. Utilization of 1H NMR in the determination of absolute configuration of alcohols

    International Nuclear Information System (INIS)

    Barreiros, Marizeth L.; David, Jorge M.; David, Juceni P. . E-juceni@ufba.br

    2005-01-01

    This review reports the determination of absolute configuration of primary and secondary alcohols by 1 H NMR spectroscopy, using the Mosher method. This method consists in the derivatization of an alcohol possessing unknown absolute configuration with one or both enantiomers of an auxiliary reagent. The resulting diastereoisomer spectra are registered and compared, and the chemical shift differences (Δδ R,S = δ R - δ S ) are measured. The determination of the absolute configuration of the alcohol molecule is based on the correlation between its chiral center and the auxiliary reagent's chiral center. Therefore, the determination of the absolute configuration depends on aromatic ring shielding effects on the substituents of the alcohol as evidenced by the 1 H NMR spectrum. (author)

  17. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  18. Determination of Absorbed Dose in Large 60-Co Fields Radiotherapy

    International Nuclear Information System (INIS)

    Hrsak, H.

    2003-01-01

    Radiation in radiotherapy has selective impact on ill and healthy tissue. During the therapy the healthy tissue receives certain amount of dose. Therefore dose calculations in outer radiotherapy must be accurate because too high doses produce damage in healthy tissue and too low doses cannot ensure efficient treatment of cancer cells. A requirement on accuracy in the dose calculations has lead to improvement of detectors, and development of absolute and relative dosimetry. Determination of the dose distribution with use of computer is based on data provided by the relative dosimetry. This paper compares the percentage depth doses in cubic water phantoms of various dimensions with percentage depth doses calculated with use of Mayneord factor from the experimental depth doses measured in water phantom of large dimension. Depth doses in water phantoms were calculated by the model of empirical dosimetrical functions. The calculations were based on the assumption that large 6 0C o photon field exceeds the phantom's limits. The experimental basis for dose calculations by the model of empirical dosimetrical functions were exposure doses measured in air and dose reduction factors because of finite phantom dimensions. Calculations were performed by fortran 90 software. It was found that the deviation of dosimetric model was small in comparison to the experimental data. (author)

  19. Absolute and relative dosimetry for ELIMED

    Energy Technology Data Exchange (ETDEWEB)

    Cirrone, G. A. P.; Schillaci, F.; Scuderi, V. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Institute of Physics Czech Academy of Science, ELI-Beamlines project, Na Slovance 2, Prague (Czech Republic); Cuttone, G.; Candiano, G.; Musumarra, A.; Pisciotta, P.; Romano, F. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania (Italy); Carpinelli, M. [INFN Sezione di Cagliari, c/o Dipartimento di Fisica, Università di Cagliari, Cagliari (Italy); Leonora, E.; Randazzo, N. [INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Presti, D. Lo [INFN-Sezione di Catania, Via Santa Sofia 64, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Raffaele, L. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and INFN-Sezione di Catania, Via Santa Sofia 64, Catania (Italy); Tramontana, A. [INFN, Laboratori Nazionali del Sud, Via Santa Sofia 62, Catania, Italy and Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy); Cirio, R.; Sacchi, R.; Monaco, V. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino, Italy and Università di Torino, Dipartimento di Fisica, Via P.Giuria, 1 10125 Torino (Italy); Marchetto, F.; Giordanengo, S. [INFN, Sezione di Torino, Via P.Giuria, 1 10125 Torino (Italy)

    2013-07-26

    The definition of detectors, methods and procedures for the absolute and relative dosimetry of laser-driven proton beams is a crucial step toward the clinical use of this new kind of beams. Hence, one of the ELIMED task, will be the definition of procedures aiming to obtain an absolute dose measure at the end of the transport beamline with an accuracy as close as possible to the one required for clinical applications (i.e. of the order of 5% or less). Relative dosimetry procedures must be established, as well: they are necessary in order to determine and verify the beam dose distributions and to monitor the beam fluence and the energetic spectra during irradiations. Radiochromic films, CR39, Faraday Cup, Secondary Emission Monitor (SEM) and transmission ionization chamber will be considered, designed and studied in order to perform a fully dosimetric characterization of the ELIMED proton beam.

  20. Dosimetric verification and evaluation of segmental multileaf collimator (SMLC)-IMRT for quality assurance. The second report. Absolute dose

    International Nuclear Information System (INIS)

    Tateoka, Kunihiko; Hareyama, Masato; Oouchi, Atsushi; Nakata, Kensei; Nagase, Daiki; Saikawa, Tsunehiko; Shimizume, Kazunari; Sugimoto, Harumi; Waka, Masaaki

    2003-01-01

    Intensity-modulated radiation therapy (IMRT) was developed to irradiate the target are more conformally, sparing organs at risk (OARs). Since the beams are sequentially delivered by many, small, irregular, and off-center fields in IMRT, dosimetric quality assurance (QA) is an extremely important issue. QA is performed by verifying both the dose distribution and doses at arbitrary points. In this work, we describe the verification of doses at arbitrary points in our hospital for Segmental multileaf collimator (SMLC)-IMRT. In general, verification of the absolute doses for IMRT is performed by comparison between the calculated doses using Radiation Treatment Planning Systems (RTP) and the measured doses using an ionization chamber with a small volume at arbitrary points in relatively flat regions of the dose gradients. However, no clear definitions of the dose gradients and the flat regions have yet been reported. We carried out verification by comparison of the measured doses with the average dose and the central point dose in a virtual Farmer type ionization chamber (V-F) and a virtual PinPoint ionization chamber (V-P) equal to the Farmer-type ionization chamber volume and PinPoint ionization chamber volumes using the RTP. Furthermore, we defined the dose gradients as the deviation of the maximum dose from the minimum dose in the virtual ionization chamber volume. In IMRT, the dose gradients may be as high as 80% or more in the virtual ionization chamber volume. Therefore, it is thought that the effective center of the ionization chamber varies by segment for IMRT fields (i.e., the variation of the ionization chamber replacement effect). Additionally, in regions with a higher dose gradient, uncertainty in the measured doses is influenced by the variations in the ionization chamber replacement effect and the ionization chamber positioning error. We more objectively examined the verification method for the absolute dose in IMRT using the virtual ionization chamber

  1. Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Nath, Ravinder

    2007-01-01

    Accurate determination of dose-rate constant (Λ) for interstitial brachytherapy sources emitting low-energy photons (<50 keV) has remained a challenge in radiation dosimetry because of the lack of a suitable absolute dosimeter for accurate measurement of the dose rates near these sources. Indeed, a consensus value of Λ taken as the arithmetic mean of the dose-rate constants determined by different research groups and dosimetry techniques has to be used at present for each source model in order to minimize the uncertainties associated with individual determinations of Λ. Because the dosimetric properties of a source are fundamentally determined by the characteristics of the photons emitted by the source, a new technique based on photon spectrometry was developed in this work for the determination of dose-rate constant. The photon spectrometry technique utilized a high-resolution gamma-ray spectrometer to measure source-specific photon characteristics emitted by the low-energy sources and determine their dose-rate constants based on the measured photon-energy spectra and known dose-deposition properties of mono-energetic photons in water. This technique eliminates many of the difficulties arising from detector size, the energy dependence of detector sensitivity, and the use of non-water-equivalent solid phantoms in absolute dose rate measurements. It also circumvents the uncertainties that might be associated with the source modeling in Monte Carlo simulation techniques. It was shown that the estimated overall uncertainty of the photon spectrometry technique was less than 4%, which is significantly smaller than the reported 8-10% uncertainty associated with the current thermo-luminescent dosimetry technique. In addition, the photon spectrometry technique was found to be stable and quick in Λ determination after initial setup and calibration. A dose-rate constant can be determined in less than two hours for each source. These features make it ideal to determine

  2. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  3. An algorithm to include the bremsstrahlung component in the determination of the absorbed dose in electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Klevenhagen, S C [The Royal London Hospital, London (United Kingdom). Medical Physics Dept.

    1996-08-01

    Currently used dosimetry protocols for absolute dose determination of electron beams from accelerators in radiation therapy do not account for the effect of the bremsstrahlung contamination of the beam. This results in slightly erroneous doses calculated from ionization chamber measurements. In this report the deviation is calculated and an improved algorithm, which accounts for the effect of the bremsstrahlung component of the beam, is suggested. (author). 14 refs, 2 figs, 1 tab.

  4. SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field

    International Nuclear Information System (INIS)

    Green, O; Li, H; Goddu, S; Mutic, S; Kawrakow, I

    2016-01-01

    Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until an engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.

  5. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Sorri, J., E-mail: juha.m.t.sorri@jyu.fi [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Greenlees, P.T.; Papadakis, P.; Konki, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Cox, D.M. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J. [University of Jyvaskyla, Department of Physics, P.O. Box 35, FI-40014 University of Jyvaskyla (Finland); Herzberg, R.-D. [Department of Physics, University of Liverpool, Oxford Street, Liverpool L69 7ZE (United Kingdom); Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G. [Department of Physics, University of York, Heslington, York YO10 5DD (United Kingdom)

    2016-03-11

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of {sup 154}Sm, {sup 152}Sm and {sup 166}Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  6. Determination of absolute internal conversion coefficients using the SAGE spectrometer

    International Nuclear Information System (INIS)

    Sorri, J.; Greenlees, P.T.; Papadakis, P.; Konki, J.; Cox, D.M.; Auranen, K.; Partanen, J.; Sandzelius, M.; Pakarinen, J.; Rahkila, P.; Uusitalo, J.; Herzberg, R.-D.; Smallcombe, J.; Davies, P.J.; Barton, C.J.; Jenkins, D.G.

    2016-01-01

    A non-reference based method to determine internal conversion coefficients using the SAGE spectrometer is carried out for transitions in the nuclei of "1"5"4Sm, "1"5"2Sm and "1"6"6Yb. The Normalised-Peak-to-Gamma method is in general an efficient tool to extract internal conversion coefficients. However, in many cases the required well-known reference transitions are not available. The data analysis steps required to determine absolute internal conversion coefficients with the SAGE spectrometer are presented. In addition, several background suppression methods are introduced and an example of how ancillary detectors can be used to select specific reaction products is given. The results obtained for ground-state band E2 transitions show that the absolute internal conversion coefficients can be extracted using the methods described with a reasonable accuracy. In some cases of less intense transitions only an upper limit for the internal conversion coefficient could be given.

  7. Absolute dose measurement Gafchromic R EBT2 movies. Case Study of Kaposis sarcoma; Medida de dosis absoluta con peliculas Gafchromic EBT2. Caso practico de un sarcoma de Kaposi

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, L.; Moral, F. del; Meilan, E.; Azevedo Gomes, J. C. de; Tejeiro Garcia, A. G.; Andrade Alvarez, B.; Vazquez, J.; Nieto, I.; Medal, D.; Lopez Medina, A.; Francisco, S.; Salgado, M.; Munoz, V.

    2011-07-01

    Because of its high spatial resolution, low energy dependence and good response over a wide energy range, EBT2 Gafchromic films are widely used in many applications in radiotherapy for measuring relative dose. Despite being the most common use can be used to measure absolute dose. This text is an example of using films as EBT2 for in vivo absolute dose in a Kaposis sarcoma.

  8. Determination of absorbed dose in a proton beam for purposes of charged-particle radiation therapy

    International Nuclear Information System (INIS)

    Verhey, L.J.; Koehler, A.M.; McDonald, J.C.; Goitein, M.; Ma, I.C.; Schneider, R.J.; Wagner, M.

    1979-01-01

    Four methods are described by which absorbed dose has been measured in a proton beam extracted from the 160-MeV Harvard cyclotron. The standard dosimetry, used to determine doses for patient treatments, is based upon an absolute measurement of particle flux using a Faraday cup. Measurements have also been made using a parallel-plate ionization chamber; a thimble ionization chamber carying a 60 Co calibration traceable to NBS; and a tissue-equivalent calorimeter. The calorimeter, which provides an independent check of the dosimetry, agreed with the standard dosimetry at five widely different depths within a range from 0.8 to 2.6%

  9. Determination of absolute detection efficiencies for detectors of interest in homeland security

    International Nuclear Information System (INIS)

    Ayaz-Maierhafer, Birsen; DeVol, Timothy A.

    2007-01-01

    The absolute total and absolute peak detection efficiencies of gamma ray detector materials NaI:Tl, CdZnTe, HPGe, HPXe, LaBr 3 :Ce and LaCl 3 :Ce were simulated and compared to that of polyvinyltoluene (PVT). The dimensions of the PVT detector were 188.82 cmx60.96 cmx5.08 cm, which is a typical size for a single-panel portal monitor. The absolute total and peak detection efficiencies for these detector materials for the point, line and spherical source geometries of 60 Co (1332 keV), 137 Cs (662 keV) and 241 Am (59.5 keV) were simulated at various source-to-detector distances using the Monte Carlo N-Particle software (MCNP5-V1.30). The comparison of the absolute total detection efficiencies for a point, line and spherical source geometry of 60 Co and 137 Cs at different source-to-detector distance showed that the absolute detection efficiency for PVT is higher relative to the other detectors of typical dimensions for that material. However, the absolute peak detection efficiency of some of these detectors are higher relative to PVT, for example the absolute peak detection efficiency of NaI:Tl (7.62 cm diameterx7.62 cm long), HPGe (7.62 cm diameterx7.62 cm long), HPXe (11.43 cm diameterx60.96 cm long), and LaCl 3 :Ce (5.08 cm diameterx5.08 cm long) are all greater than that of a 188.82 cmx60.96 cmx5.08 cm PVT detector for 60 Co and 137 Cs for all geometries studied. The absolute total and absolute peak detection efficiencies of a right circular cylinder of NaI:Tl with various diameters and thicknesses were determined for a point source. The effect of changing the solid angle on the NaI:Tl detectors showed that with increasing solid angle and detector thickness, the absolute efficiency increases. This work establishes a common basis for differentiating detector materials for passive portal monitoring of gamma ray radiation

  10. SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

    International Nuclear Information System (INIS)

    Chu, A; Ahmad, M; Chen, Z; Nath, R; Feng, W

    2014-01-01

    Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions

  11. SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration

    Energy Technology Data Exchange (ETDEWEB)

    Chu, A; Ahmad, M; Chen, Z; Nath, R [Yale New Haven Hospital/School of Medicine Yale University, New Haven, CT (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States)

    2014-06-01

    Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilities of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions

  12. Mosher Amides: Determining the Absolute Stereochemistry of Optically-Active Amines

    Science.gov (United States)

    Allen, Damian A.; Tomaso, Anthony E., Jr.; Priest, Owen P.; Hindson, David F.; Hurlburt, Jamie L.

    2008-01-01

    The use of chiral reagents for the derivatization of optically-active amines and alcohols for the purpose of determining their enantiomeric purity or absolute configuration is a tool used by many chemists. Among the techniques used, Mosher's amide and Mosher's ester analyses are among the most reliable and one of the most often used. Despite this,…

  13. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  14. Determination of the absolute configuration of (+) - surinamensin's via diastereomeric O-methylmandelic esters

    International Nuclear Information System (INIS)

    Santos, L. da S.; Barata, L.E.S.

    1990-01-01

    The absolute configurarion of (+) surinamensin, a 8.0.4' neolignan, has been determined based on its O-methymandalates esters. Nuclear magnetic resonance and infrared and mass spectroscopy analysis are presented. (C.G.C.) [pt

  15. Pharmacokinetic evaluation of pamidronate after oral administration: a study on dose proportionality, absolute bioavailability, and effect of repeated administration

    DEFF Research Database (Denmark)

    Hyldstrup, Lars; Flesch, G; Hauffe, S A

    1993-01-01

    30 minutes at constant infusion rate. Repeated peroral doses (75 and 150 mg) were administered to 12 females (aged 51-70 years) for 10 consecutive days. Urinary excretion of pamidronate after peroral and i.v. administration was used for estimation of pamidronate absorption. Renal excretion...... of pamidronate ranged from 0.01% to 0.35% of dose, with mean values of 0.11, 0.16, and 0.18% for 75, 150, and 300 mg, respectively. After i.v. infusion, the renal excretion of pamidronate was 26-53% of the dose, lower than for other bisphosphonates. The absolute bioavailability was 0.31% (range 0.08-0.7%) after...

  16. ABSOLUTE NEUTRINO MASSES

    DEFF Research Database (Denmark)

    Schechter, J.; Shahid, M. N.

    2012-01-01

    We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos.......We discuss the possibility of using experiments timing the propagation of neutrino beams over large distances to help determine the absolute masses of the three neutrinos....

  17. Pharmacokinetics of fexofenadine: evaluation of a microdose and assessment of absolute oral bioavailability.

    Science.gov (United States)

    Lappin, Graham; Shishikura, Yoko; Jochemsen, Roeline; Weaver, Richard John; Gesson, Charlotte; Houston, Brian; Oosterhuis, Berend; Bjerrum, Ole J; Rowland, Malcolm; Garner, Colin

    2010-05-12

    A human pharmacokinetic study was performed to assess the ability of a microdose to predict the pharmacokinetics of a therapeutic dose of fexofenadine and to determine its absolute oral bioavailability. Fexofenadine was chosen to represent an unmetabolized transporter substrate (P-gP and OATP). Fexofenadine was administered to 6 healthy male volunteers in a three way cross-over design. A microdose (100microg) of (14)C-drug was administered orally (period 1) and intravenously by 30min infusion (period 2). In period 3 an intravenous tracer dose (100microg) of (14)C-drug was administered simultaneously with an oral unlabelled therapeutic dose (120mg). Plasma was collected from all 3 periods and analysed for both total (14)C content and parent drug by accelerator mass spectrometry (AMS). For period 3, plasma samples were also analysed using HPLC-fluorescence to determine total drug concentration. Urine was collected and analysed for total (14)C. Good concordance between the microdose and therapeutic dose pharmacokinetics was observed. Microdose: CL 13L/h, CL(R) 4.1L/h, V(ss) 54L, t(1/2) 16h; therapeutic dose: CL 16L/h, CL(R) 6.2L/h, V(ss) 64L, t(1/2) 12h. The absolute oral bioavailability of fexofenadine was 0.35 (microdose 0.41, therapeutic dose 0.30). Despite a 1200-fold difference in dose of fexofenadine, the microdose predicted well the pharmacokinetic parameters following a therapeutic dose for this transporter dependent compound.

  18. Fast, Computer Supported Experimental Determination of Absolute Zero Temperature at School

    Science.gov (United States)

    Bogacz, Bogdan F.; Pedziwiatr, Antoni T.

    2014-01-01

    A simple and fast experimental method of determining absolute zero temperature is presented. Air gas thermometer coupled with pressure sensor and data acquisition system COACH is applied in a wide range of temperature. By constructing a pressure vs temperature plot for air under constant volume it is possible to obtain--by extrapolation to zero…

  19. Metrological activity determination of {sup 133}Ba by sum-peak absolute method

    Energy Technology Data Exchange (ETDEWEB)

    Silva, R.L. da; Delgado, J.U.; Poledna, R.; Santos, A.; Veras, E.V. de; Rangel, J.; Trindade, O.L. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.br, E-mail: candida@cnen.gov.br [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The National Laboratory for Metrology of Ionizing Radiation provides gamma sources of radionuclide and standardized in activity with reduced uncertainties. Relative methods require standards to determine the sample activity while the absolute methods, as sum-peak, not. The activity is obtained directly with good accuracy and low uncertainties. {sup 133}Ba is used in research laboratories and on calibration of detectors for analysis in different work areas. Classical absolute methods do not calibrate {sup 133}Ba due to its complex decay scheme. The sum-peak method using gamma spectrometry with germanium detector standardizes {sup 133}Ba samples. Uncertainties lower than 1% to activity results were obtained.

  20. Comprehensive fluence model for absolute portal dose image prediction

    International Nuclear Information System (INIS)

    Chytyk, K.; McCurdy, B. M. C.

    2009-01-01

    Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) continue to be investigated as treatment verification tools, with a particular focus on intensity modulated radiation therapy (IMRT). This verification could be accomplished through a comparison of measured portal images to predicted portal dose images. A general fluence determination tailored to portal dose image prediction would be a great asset in order to model the complex modulation of IMRT. A proposed physics-based parameter fluence model was commissioned by matching predicted EPID images to corresponding measured EPID images of multileaf collimator (MLC) defined fields. The two-source fluence model was composed of a focal Gaussian and an extrafocal Gaussian-like source. Specific aspects of the MLC and secondary collimators were also modeled (e.g., jaw and MLC transmission factors, MLC rounded leaf tips, tongue and groove effect, interleaf leakage, and leaf offsets). Several unique aspects of the model were developed based on the results of detailed Monte Carlo simulations of the linear accelerator including (1) use of a non-Gaussian extrafocal fluence source function, (2) separate energy spectra used for focal and extrafocal fluence, and (3) different off-axis energy spectra softening used for focal and extrafocal fluences. The predicted energy fluence was then convolved with Monte Carlo generated, EPID-specific dose kernels to convert incident fluence to dose delivered to the EPID. Measured EPID data were obtained with an a-Si EPID for various MLC-defined fields (from 1x1 to 20x20 cm 2 ) over a range of source-to-detector distances. These measured profiles were used to determine the fluence model parameters in a process analogous to the commissioning of a treatment planning system. The resulting model was tested on 20 clinical IMRT plans, including ten prostate and ten oropharyngeal cases. The model predicted the open-field profiles within 2%, 2 mm, while a mean of 96.6% of pixels over all

  1. Determining organ dose: the holy grail

    International Nuclear Information System (INIS)

    Samei, Ehsan; Tian, Xiaoyu; Segars, W.P.

    2014-01-01

    Among the various metrics to quantify CT radiation dose, organ dose is generally regarded as one of the best to reflect patient radiation burden. Organ dose is dependent on two main factors, namely patient anatomy and irradiation field. An accurate estimation of organ dose requires detailed modeling of both factors. The modeling of patient anatomy needs to reflect the anatomical diversity and complexity across the population so that the attributes of a given clinical patient can be properly accounted for. The modeling of the irradiation field needs to accurately reflect the CT system condition, especially the tube current modulation (TCM) technique. We present an atlas-based method to model patient anatomy via a library of computational phantoms with representative ages, sizes and genders. A clinical patient is matched with a corresponding computational phantom to obtain a representation of patient anatomy. The irradiation field of the CT system is modeled using a validated Monte Carlo simulation program. The tube current modulation profiles are simulated using a manufacturer-generalizable ray-tracing algorithm. Combining the patient model, Monte Carlo results, and TCM profile, organ doses are obtained by multiplying organ dose values from a fixed mA scan (normalized to CTDI vol -normalized, denoted as h organ ) and an adjustment factor that reflects the specific irradiation of each organ. The accuracy of the proposed method was quantified by simulating clinical abdominopelvic examinations of 58 patients. The predicted organ doses showed good agreement with simulated organ dose across all organs and modulation schemes. For an average CTDI vol of a CT exam of 10 mGy, the absolute median error across all organs was 0.64 mGy (-0.21 and 0.97 for 25th and 75th percentiles, respectively). The percentage differences were within 15%. The study demonstrates that it is feasible to estimate organ doses in clinical CT examinations for protocols without and with tube current

  2. Determination of the absolute activity by the coincidences 4πβ-γ method

    International Nuclear Information System (INIS)

    Urcelay Silva, A.J.

    1975-01-01

    The 4π beta-gamma coincidence method for absolute determination of activities is extremely important in the production of high-precision radioactive sources. By means of this method it is possible to obtain absolute measurements of decay to within 0.1%. Thanks to the high efficiency of the 4π counter, most of the corrections required - background, random coincidences, dead time, decay scheme and detector efficiency - are small. The paper describes the experimental set-up showing the pulses in the two branches of the system, together with the conditions under which the 4πbeta flux detector functions. To determine whether the system was functioning satisfactorily, the activity of four cobalt-60 standards (supplied by the International Bureau of Weights and Measures based at Sevres in France) was determined and the differences obtained were less than 0.5% with respect to the certificates accompanying the sources. Alterations to the flux detector are suggested so that higher accuracy may be obtained. (author)

  3. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    Science.gov (United States)

    Chalouhi, Ch.; Hourani, E.; Loos, R.; Melki, S.

    1982-09-01

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained.

  4. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    International Nuclear Information System (INIS)

    Chalouhi, C.; Hourani, E.; Loos, R.; Melki, S.

    1982-01-01

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained. (orig.)

  5. Absolute determination of copper and silver in ancient coins using 14 MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Chalouhi, C.; Hourani, E.; Loos, R.; Melki, S. (Faculty of Science, Beirut (Lebanon))

    1982-09-15

    A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained.

  6. SU-F-T-347: An Absolute Dose-Volume Constraint Based Deterministic Optimization Framework for Multi-Co60 Source Focused Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liang, B; Liu, B; Li, Y; Guo, B; Xu, X; Wei, R; Zhou, F [Beihang University, Beijing, Beijing (China); Wu, Q [Duke University Medical Center, Durham, NC (United States)

    2016-06-15

    Purpose: Treatment plan optimization in multi-Co60 source focused radiotherapy with multiple isocenters is challenging, because dose distribution is normalized to maximum dose during optimization and evaluation. The objective functions are traditionally defined based on relative dosimetric distribution. This study presents an alternative absolute dose-volume constraint (ADC) based deterministic optimization framework (ADC-DOF). Methods: The initial isocenters are placed on the eroded target surface. Collimator size is chosen based on the area of 2D contour on corresponding axial slice. The isocenter spacing is determined by adjacent collimator sizes. The weights are optimized by minimizing the deviation from ADCs using the steepest descent technique. An iterative procedure is developed to reduce the number of isocenters, where the isocenter with lowest weight is removed without affecting plan quality. The ADC-DOF is compared with the genetic algorithm (GA) using the same arbitrary shaped target (254cc), with a 15mm margin ring structure representing normal tissues. Results: For ADC-DOF, the ADCs imposed on target and ring are (D100>10Gy, D50,10, 0<12Gy, 15Gy and 20Gy) and (D40<10Gy). The resulting D100, 50, 10, 0 and D40 are (9.9Gy, 12.0Gy, 14.1Gy and 16.2Gy) and (10.2Gy). The objectives of GA are to maximize 50% isodose target coverage (TC) while minimize the dose delivered to the ring structure, which results in 97% TC and 47.2% average dose in ring structure. For ADC-DOF (GA) techniques, 20 out of 38 (10 out of 12) initial isocenters are used in the final plan, and the computation time is 8.7s (412.2s) on an i5 computer. Conclusion: We have developed a new optimization technique using ADC and deterministic optimization. Compared with GA, ADC-DOF uses more isocenters but is faster and more robust, and achieves a better conformity. For future work, we will focus on developing a more effective mechanism for initial isocenter determination.

  7. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  8. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A. [Department of Radiological Sciences, St Jude Children' s Research Hospital, Memphis, Tennessee 38105 (United States); Mirro, Amy E. [Department of Biomedical Engineering, Washington University, St Louis, Missouri 63130 (United States)

    2014-07-15

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. The CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to

  9. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources

    International Nuclear Information System (INIS)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila

    2014-01-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose

  10. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1988-01-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed

  11. New Compounds from Euphorbia helioscopia and Absolute Configuration Determination by Computational Methods

    International Nuclear Information System (INIS)

    He, Jiangbo; Zhu, Hua Jie; Luo, Gui Fen; Li, Yan; Cheng, Yong Xian; Chen, Hao; Chen, Shaopeng; Lu, Xin; Zhou, Guochun; Liu, Guang Ming

    2010-01-01

    The whole plant of Euphorbia helioscopia is an important traditional Chinese medicine. Fom its BuOH soluble extract, one new lactam, three new terpenoids including a new naturally occurring compound, and three known compounds were isolated. Their structures were identified by spectroscopic evidences. In particular, the absolute configurations of side chain of compounds 1 and 2 were determined using computational methods

  12. Absolute bioavailability of evacetrapib in healthy subjects determined by simultaneous administration of oral evacetrapib and intravenous [13C8]‐evacetrapib as a tracer

    Science.gov (United States)

    Aburub, Aktham; Ward, Chris; Hinds, Chris; Czeskis, Boris; Ruterbories, Kenneth; Suico, Jeffrey G.; Royalty, Jane; Ortega, Demetrio; Pack, Brian W.; Begum, Syeda L.; Annes, William F.; Lin, Qun; Small, David S.

    2015-01-01

    This open‐label, single‐period study in healthy subjects estimated evacetrapib absolute bioavailability following simultaneous administration of a 130‐mg evacetrapib oral dose and 4‐h intravenous (IV) infusion of 175 µg [13C8]‐evacetrapib as a tracer. Plasma samples collected through 168 h were analyzed for evacetrapib and [13C8]‐evacetrapib using high‐performance liquid chromatography/tandem mass spectrometry. Pharmacokinetic parameter estimates following oral and IV doses, including area under the concentration‐time curve (AUC) from zero to infinity (AUC[0‐∞]) and to the last measureable concentration (AUC[0‐tlast]), were calculated. Bioavailability was calculated as the ratio of least‐squares geometric mean of dose‐normalized AUC (oral : IV) and corresponding 90% confidence interval (CI). Bioavailability of evacetrapib was 44.8% (90% CI: 42.2–47.6%) for AUC(0‐∞) and 44.3% (90% CI: 41.8–46.9%) for AUC(0‐tlast). Evacetrapib was well tolerated with no reports of clinically significant safety assessment findings. This is among the first studies to estimate absolute bioavailability using simultaneous administration of an unlabeled oral dose with a 13C‐labeled IV microdose tracer at about 1/1000th the oral dose, with measurement in the pg/mL range. This approach is beneficial for poorly soluble drugs, does not require additional toxicology studies, does not change oral dose pharmacokinetics, and ultimately gives researchers another tool to evaluate absolute bioavailability. PMID:26639670

  13. Proton spectroscopic imaging of polyacrylamide gel dosimeters for absolute radiation dosimetry

    International Nuclear Information System (INIS)

    Murphy, P.S.; Schwarz, A.J.; Leach, M.O.

    2000-01-01

    Proton spectroscopy has been evaluated as a method for quantifying radiation induced changes in polyacrylamide gel dosimeters. A calibration was first performed using BANG-type gel samples receiving uniform doses of 6 MV photons from 0 to 9 Gy in 1 Gy intervals. The peak integral of the acrylic protons belonging to acrylamide and methylenebisacrylamide normalized to the water signal was plotted against absorbed dose. Response was approximately linear within the range 0-7 Gy. A large gel phantom irradiated with three, coplanar 3x3cm square fields to 5.74 Gy at isocentre was then imaged with an echo-filter technique to map the distribution of monomers directly. The image, normalized to the water signal, was converted into an absolute dose map. At the isocentre the measured dose was 5.69 Gy (SD = 0.09) which was in good agreement with the planned dose. The measured dose distribution elsewhere in the sample shows greater errors. A T 2 derived dose map demonstrated a better relative distribution but gave an overestimate of the dose at isocentre of 18%. The data indicate that MR measurements of monomer concentration can complement T 2 -based measurements and can be used to verify absolute dose. Compared with the more usual T 2 measurements for assessing gel polymerization, monomer concentration analysis is less sensitive to parameters such as gel pH and temperature, which can cause ambiguous relaxation time measurements and erroneous absolute dose calculations. (author)

  14. Effect of various methods for rectum delineation on relative and absolute dose-volume histograms for prostate IMRT treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Kusumoto, Chiaki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Ohira, Shingo [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita (Japan); Miyazaki, Masayoshi [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Ueda, Yoshihiro [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Department of Radiation Oncology, Graduate School of Medicine, Osaka University, Suita (Japan); Isono, Masaru [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki, E-mail: teshima-te@mc.pref.osaka.jp [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan)

    2016-07-01

    Several reports have dealt with correlations of late rectal toxicity with rectal dose-volume histograms (DVHs) for high dose levels. There are 2 techniques to assess rectal volume for reception of a specific dose: relative-DVH (R-DVH, %) that indicates relative volume for a vertical axis, and absolute-DVH (A-DVH, cc) with its vertical axis showing absolute volume of the rectum. The parameters of DVH vary depending on the rectum delineation method, but the literature does not present any standardization of such methods. The aim of the present study was to evaluate the effects of different delineation methods on rectal DVHs. The enrollment for this study comprised 28 patients with high-risk localized prostate cancer, who had undergone intensity-modulated radiation therapy (IMRT) with the prescription dose of 78 Gy. The rectum was contoured with 4 different methods using 2 lengths, short (Sh) and long (Lg), and 2 cross sections, rectum (Rec) and rectal wall (Rw). Sh means the length from 1 cm above the seminal vesicles to 1 cm below the prostate and Lg the length from the rectosigmoid junction to the anus. Rec represents the entire rectal volume including the rectal contents and Rw the rectal volume of the area with a wall thickness of 4 mm. We compared dose-volume parameters by using 4 rectal contour methods for the same plan with the R-DVHs as well as the A-DVHs. For the high dose levels, the R-DVH parameters varied widely. The mean of V{sub 70} for Sh-Rw was the highest (19.4%) and nearly twice as high as that for Lg-Rec (10.4%). On the contrary, only small variations were observed in the A-DVH parameters (4.3, 4.3, 5.5, and 5.5 cc for Sh-Rw, Lg-Rw, Sh-Rec, and Lg-Rec, respectively). As for R-DVHs, the parameters of V{sub 70} varied depending on the rectal lengths (Sh-Rec vs Lg-Rec: R = 0.76; Sh-Rw vs Lg-Rw: R = 0.85) and cross sections (Sh-Rec vs Sh-Rw: R = 0.49; Lg-Rec vs Lg-Rw: R = 0.65). For A-DVHs, however, the parameters of Sh rectal A-DVHs hardly changed

  15. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  16. Absolute quantification of pharmacokinetic distribution of RES colloids in individuals with normal liver function

    International Nuclear Information System (INIS)

    Herzog, H.; Spohr, G.; Notohamiprodjo, G.; Feinendegen, L.E.

    1987-01-01

    Estimates of the radiation dose resulting from liver-spleen scintigraphy 99 TCsup(m)-labelled colloids are based on pharmacokinetic data mainly determined in animals. The aim of this study was to check the pharmacokinetic data by direct, absolute in vivo quantification in man. Liver and spleen activities were directly measured using a double-energy window technique. Activities in other organs were quantified by conjugate whole-body scans. All measurement procedures were checked using the whole-body Alderson phantom. Pharmacokinetic data for sulphur colloid, tin colloid, human serum albumin (HSA) millimicrospheres, and phytate were obtained in 13 to 20 normal subjects for each type of colloid. Depending on the colloid type liver uptake was between 54 and 75% of the total administered dose (TAD) and spleen uptake was 3.5 to 21% TAD. Activity measured in blood, urine, lung and thyroid proved to be far from negligible. The results of this work suggest a correction of the animal-based data of colloid distribution and radiation dose on the basis of the direct measurement of absolute uptake in man. (author)

  17. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  18. Research on determine the absolute neutron output of distributed pulse generators

    International Nuclear Information System (INIS)

    Li Bojun; Tang Zhangkui; Wang Dong; Yang Gaozhao; Peng Taiping

    2009-01-01

    In order to determine the absolute neutron output of distributed pulse generators, we deduced equivalent length to deal with experimental data, according to the different layout and weighting of multiple pulse generators. The deposited energy in scintillation crystal and the integral flux which drilling through crystal interface was simulated by MCNP code. The result shows the simulated proportion of different distributed pulse generators is approximately agreed with experimental data. The validity of the equivalent length model was proved by the consistent results between calculation and experimental data. (authors)

  19. A Method for Absolute Determination of the Surface Areal Density of Functional Groups in Organic Thin Films

    Energy Technology Data Exchange (ETDEWEB)

    Min, Hyegeun; Son, Jin Gyeong; Kim, Jeong Won; Yu, Hyunung; Lee, Tae Geol; Moon, Dae Won [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2014-03-15

    To develop a methodology for absolute determination of the surface areal density of functional groups on organic and bio thin films, medium energy ion scattering (MEIS) spectroscopy was utilized to provide references for calibration of X-ray photoelectron spectroscopy (XPS) or Fourier transformation-infrared (FT-IR) intensities. By using the MEIS, XPS, and FT-IR techniques, we were able to analyze the organic thin film of a Ru dye compound (C{sub 58}H{sub 86}O{sub 8}N{sub 8}S{sub 2}Ru), which consists of one Ru atom and various stoichiometric functional groups. From the MEIS analysis, the absolute surface areal density of Ru atoms (or Ru dye molecules) was determined. The surface areal densities of stoichiometric functional groups in the Ru dye compound were used as references for the calibration of XPS and FT-IR intensities for each functional group. The complementary use of MEIS, XPS, and FT-IR to determine the absolute surface areal density of functional groups on organic and bio thin films will be useful for more reliable development of applications based on organic thin films in areas such as flexible displays, solar cells, organic sensors, biomaterials, and biochips.

  20. Derivation, evidence and physical validity of a weighted beam-zone method for dose determination in blocked photon fields of arbitrary shape

    International Nuclear Information System (INIS)

    Glaeser, L.; Quast, U.

    1981-01-01

    A simple, practical procedure for dose determination at any point of an arbitrarily shaped field has been derived: Square-field photon beams are sectioned into a set of pyramid-shell-like parts (beam zones), nested into each other around the smallest realizable square field, of different sizes but with equal dose contributions (thus weighted) with respect to a central dose reference point. The dose at any reference point in an irregular field can be determined simply by counting the number of non-shielded dose-contributing zones (or zone fractions), leading to the associated order of square-field size (with the same number of zones), the equivalent field with known dose. For experimental evidence of the validity of the weighted beam-zone method, measurements were carried out with different high-energy photon beams with one or more beam zones shielded by absorbing blocks. Measurements were made at points in unshielded and shielded parts of the field, on and off the beam axis and at different depths in a phantom. Calculations and measurements were compared. While relative depth doses were shown to be equal to within +-2% over a range of 5 cm ahead of and behind the dose reference point, the absolute dose deviations were within +-4%. The sources of error were analysed. They were mainly determined by scattered radiation from the beam limiting device and the partial shielding deriving from the shielding blocks. The same errors also occur in most of the known methods of dose calculation in irregular fields. (author)

  1. Absolute Oral Bioavailability of Creatine Monohydrate in Rats: Debunking a Myth.

    Science.gov (United States)

    Alraddadi, Eman A; Lillico, Ryan; Vennerstrom, Jonathan L; Lakowski, Ted M; Miller, Donald W

    2018-03-08

    Creatine is an ergogenic compound used by athletes to enhance performance. Supplementation with creatine monohydrate (CM) has been suggested for musculoskeletal and neurological disorders. Until now, little is known about its pharmacokinetic profile. Our objective was to determine the oral bioavailability of CM and the influence of dose on oral absorption. Rats were dosed orally with low dose (10 mg/kg) or high dose (70 mg/kg) 13 C-labeled CM. Blood samples were removed at various time points. Muscle and brain tissue were collected at the conclusion of the study. Plasma and tissue levels of 13 C-labeled creatine were determined using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Physiologically based pharmacokinetic (PBPK) models of CM were built using GastroPlus™. These models were used to predict the plasma concentration-time profiles of creatine hydrochloride (CHCL), which has improved aqueous solubility compared to CM. Absolute oral bioavailability for low dose CM was 53% while high dose CM was only 16%. The simulated C max of 70 mg/kg CHCL was around 35 μg/mL compared to 14 μg/mL for CM with a predicted oral bioavailability of 66% with CHCL compared to 17% with CM. Our results suggest that the oral bioavailability of CM is less than complete and subject to dose and that further examination of improved dosage formulations of creatine is warranted.

  2. Accurate measurement of the optical activity of alanine crystals and the determination of their absolute chirality

    Science.gov (United States)

    Ishikawa, Kazuhiko; Terasawa, Yukana; Tanaka, Masahito; Asahi, Toru

    2017-05-01

    Wavelength dependence measurements of the chiroptical properties in alanine crystals have so far been unsuccessful using conventional spectroscopic techniques. We describe our attempts to measure the wavelength dependence of the optical activity in L- and D-alanine crystals along each crystallographic axis, and to determine the absolute chirality of alanine crystals by correlating the absolute structure to the optical activity using an x-ray diffractometer and a generalized high accuracy universal polarimeter. We have succeeded in accurately measuring the optical rotatory dispersion in the direction, which shows that the optical rotation of the D-alanine crystal is dextrorotatory and that of the L-alanine crystal is laevorotatory, thereby determining the absolute chirality. Furthermore, comparison with the optical activity in solution shows that the optical activity in alanine crystals is different not only in value, but also in the sign. These results have led us to conclude that the optical rotatory power in the crystalline state should not be simply the summation of molecular optical rotatory power values. We propose the necessity of a theory, which contains the contribution of molecular interactions within the crystal, in order to calculate the optical rotatory power of the crystalline state.

  3. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature.

    Science.gov (United States)

    Schmuck, S; Fessey, J; Gerbaud, T; Alper, B; Beurskens, M N A; de la Luna, E; Sirinelli, A; Zerbini, M

    2012-12-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron temperature is determined from the measurements. The current state of the interferometer hardware, the calibration setup, and the analysis technique for calibration and plasma operation are described. A new, full-system, absolute calibration employing continuous data acquisition has been performed recently and the calibration method and results are presented. The noise level in the measurement is very low and as a result the electron cyclotron emission spectrum and thus the spatial profile of the electron temperature are determined to within ±5% and in the most relevant region to within ±2%. The new calibration shows that the absolute response of the system has decreased by about 15% compared to that measured previously and possible reasons for this change are presented. Temperature profiles measured with the Michelson interferometer are compared with profiles measured independently using Thomson scattering diagnostics, which have also been recently refurbished and recalibrated, and agreement within experimental uncertainties is obtained.

  4. Determination of the dose and dose distribution in radiation-linked polyolefins

    International Nuclear Information System (INIS)

    Andress, B.; Fischer, P.; Repp, H.H.; Roehl, P.

    1984-01-01

    The method serves the determination of the radiation dose and dose distribution in polyolefins cross-linked by electron beams; the cross-linking takes place in the presence of an additive which is inserted in the polyolefin by radiation. After the cross-linking the fraction of the additive which is not inserted will be extracted from the polyolefin and afterwards the total extinction of the polyolefin will be determined by photometry. This process allows in particular the determination of the quality of the irradiation conditions for the electron-beam cross-linking of medium-voltage cables insulated by polyolefins. (orig.) [de

  5. Determination of the absolute configuration of monosaccharides in complex carbohydrates by capillary G.L.C.

    NARCIS (Netherlands)

    Vliegenthart, J.F.G.; Gerwig, G.J.; Kamerling, J.P.

    1979-01-01

    The absolute configuration of neutral monosaccharides, 2-acetamido-2-deoxy sugars, and uronic acids can be determined by capillary g.l.c. on SE-30 after glycosidation with (-)-2-butanol and protection of the remaining polar groups. The method is illustrated by application to mixtures of the

  6. Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter.

    Science.gov (United States)

    Harty, P D; Lye, J E; Ramanathan, G; Butler, D J; Hall, C J; Stevenson, A W; Johnston, P N

    2014-05-01

    The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. The good agreement of

  7. Radiotherapy reference dose audit in the United Kingdom by the National Physical Laboratory: 20 years of consistency and improvements

    Directory of Open Access Journals (Sweden)

    Russell A.S. Thomas

    2017-07-01

    Conclusions: The introduction of the 2003 electron code of practice based on absorbed dose to water decreased the difference between absolute dose measurements by the centre and NPL. The use of a single photon code of practice over the period of measurements has contributed to a reduction in measurement variation. Within the clinical setting, on-site audit visits have been shown to identify areas of improvement for determining and implementing absolute dose calibrations.

  8. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis.

    Science.gov (United States)

    Yuan, H S; Stevens, R C; Bau, R; Mosher, H S; Koetzle, T F

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanal-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH3)3 group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH3)3 groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2(1) (monoclinic), a = 18.564(6) A, b = 7.713(2) A, c = 23.361(8) A, beta = 94.18(4) degrees, V = 3336.0(5) A3, Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis).

  9. Bioavailability of diclofenac potassium at low doses

    Science.gov (United States)

    Hinz, Burkhard; Chevts, Julia; Renner, Bertold; Wuttke, Henrike; Rau, Thomas; Schmidt, Andreas; Szelenyi, Istvan; Brune, Kay; Werner, Ulrike

    2005-01-01

    Aim Diclofenac-K has been recently launched at low oral doses in different countries for over-the-counter use. However, given the considerable first-pass metabolism of diclofenac, the degree of absorption of diclofenac-K at low doses remained to be determined. The aim of this study was to determine the bioavailability of low-dose diclofenac-K. Methods A randomized, three-way, cross-over study was performed in 10 subjects. Each received diclofenac-K, 22.5 mg via short-term i.v. infusion and orally at single doses of 12.5 mg and 25 mg. Results Mean (± SD) times to maximal plasma concentration (tmax) of diclofenac were 0.48 ± 0.28 h (12.5 mg) and 0.93 ± 0.96 h (25 mg). The absolute bioavailability of diclofenac-K after oral administration did not differ significantly in the 12.5-mg and 25-mg dose group (63.1 ± 12.6% vs. 65.1 ± 19.4%, respectively). The 90% confidence intervals for the AUC∞ and AUCt ratios for the two oral regimes were 82.6, 103.4% (point estimate 92.4%) and 86.2, 112.9% (point estimate 98.6%), respectively. These values were within the acceptance criteria for bioequivalence (80–125%). Conclusions Our data indicate that diclofenac-K is rapidly and well absorbed at low dose, and are consistent with a rapid onset of action of the drug. Abbreviations AUC, area under plasma concentraton-time curve; Cmax, peak plasma concentration; CI, confidence interval; COX, cyclooxygenase; D, dose; F, absolute bioavailability; tmax, time to reach Cmax. PMID:15606444

  10. Absolute entropy of ions in methanol

    International Nuclear Information System (INIS)

    Abakshin, V.A.; Kobenin, V.A.; Krestov, G.A.

    1978-01-01

    By measuring the initial thermoelectromotive forces of chains with bromo-silver electrodes in tetraalkylammonium bromide solutions the absolute entropy of bromide-ion in methanol is determined in the 298.15-318.15 K range. The anti Ssub(Brsup(-))sup(0) = 9.8 entropy units value is used for calculation of the absolute partial molar entropy of alkali metal ions and halogenide ions. It has been found that, absolute entropy of Cs + =12.0 entropy units, I - =14.0 entropy units. The obtained ion absolute entropies in methanol at 298.15 K within 1-2 entropy units is in an agreement with published data

  11. Wide-range neutron dose determination with CR-39

    International Nuclear Information System (INIS)

    Arneja, A.R.; Waker, A.J.

    1995-01-01

    Optical density measurements of CR-30 irradiated with 252 Cf neutrons and chemically etched with 6.5 N KOH solution have been used to determine neutron absorbed doses between 0.1 and 10 Gy. Optimum etching conditions will depend upon the absorbed dose. Since it is not always possible to know the range of absorbed dose on a CR-39 dosemeter collected from personnel and area monitor stations in a criticality accident situation, a three-step two-hour chemical etch at 60 o C has been found to be appropriate. If after a total of six hours of chemical etching the optical density is found to be below 0.04 for 500 nm light (transmission > 90%) then further treatment in the form of electrochemical etching can be carried out to determine the lower absorbed dose. In this manner, absorbed doses below 0.1 Gy can be determined by counting tracks over a unit area. (author)

  12. Dose-rate determination by radiochemical analysis

    International Nuclear Information System (INIS)

    Mangini, A.; Pernicka, E.; Wagner, G.A.

    1983-01-01

    At the previous TL Specialist Seminr we had suggested that α-counting is an unsuitable technique for dose-rate determination due to overcounting effects. This is confirmed by combining α-counting, neutron activation analysis, fission track counting, α-spectrometry on various pottery samples. One result of this study is that disequilibrium in the uranium decay chain alone cannot account for the observed discrepancies between α-counting and chemical analysis. Therefore we propose for routine dose-rate determination in TL dating to apply chemical analysis of the radioactive elements supplemented by an α-spectrometric equilibrium check. (author)

  13. a Chiral Tagging Strategy for Determining Absolute Configuration and Enantiomeric Excess by Molecular Rotational Spectroscopy

    Science.gov (United States)

    Evangelisti, Luca; Caminati, Walther; Patterson, David; Thomas, Javix; Xu, Yunjie; West, Channing; Pate, Brooks

    2017-06-01

    The introduction of three wave mixing rotational spectroscopy by Patterson, Schnell, and Doyle [1,2] has expanded applications of molecular rotational spectroscopy into the field of chiral analysis. Chiral analysis of a molecule is the quantitative measurement of the relative abundances of all stereoisomers of the molecule and these include both diastereomers (with distinct molecular rotational spectra) and enantiomers (with equivalent molecular rotational spectra). This work adapts a common strategy in chiral analysis of enantiomers to molecular rotational spectroscopy. A "chiral tag" is attached to the molecule of interest by making a weakly bound complex in a pulsed jet expansion. When this tag molecule is enantiopure, it will create diastereomeric complexes with the two enantiomers of the molecule being analyzed and these can be differentiated by molecule rotational spectroscopy. Identifying the structure of this complex, with knowledge of the absolute configuration of the tag, establishes the absolute configuration of the molecule of interest. Furthermore, the diastereomer complex spectra can be used to determine the enantiomeric excess of the sample. The ability to perform chiral analysis will be illustrated by a study of solketal using propylene oxide as the tag. The possibility of using current methods of quantum chemistry to assign a specific structure to the chiral tag complex will be discussed. Finally, chiral tag rotational spectroscopy offers a "gold standard" method for determining the absolute configuration of the molecule through determination of the substitution structure of the complex. When this measurement is possible, rotational spectroscopy can deliver a quantitative three dimensional structure of the molecule with correct stereochemistry as the analysis output. [1] David Patterson, Melanie Schnell, John M. Doyle, Nature 497, 475 (2013). [2] David Patterson, John M. Doyle, Phys. Rev. Lett. 111, 023008 (2013).

  14. Determination of effective dose of antimalarial from Cassia ...

    African Journals Online (AJOL)

    However, further investigation is required to determine an effective dose of the administered extract for a higher inhibitory effect and increasing effectiveness of the extract. Material and Methods: To determine the effective dose of ethanol extract of C. spectabilis leaves, a "4-day suppressive test"of Peter was performed with ...

  15. Determination of key radionuclides and parameters related to dose from the Columbia River pathway

    International Nuclear Information System (INIS)

    Napier, B.A.

    1993-03-01

    A series of scoping calculations has been undertaken to evaluate the absolute and relative contributions of different radionuclides and exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford Site. These scoping calculations may include some radionuclides and pathways that were included in the Phase 1 Columbia River pathway dose evaluations, as well as other potential exposure pathways being evaluated for possible inclusion in future Hanford Environmental Dose Reconstruction Project (HEDR) modeling efforts. This scoping calculation (Calculation 009) examines the contributions of numerous radionuclides to dose via environmental exposures and accumulation in water, fish, and other aquatic biota. Addressed in these calculations are the contributions to effective dose from (1) external exposure to contaminated river water, ( 2) ingestion of contaminated drinking water, and (3) ingestion of contaminated resident Columbia River fish. Additional information on contamination of anadromous fish and waterfowl is provided

  16. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, H.S.H.; Stevens, R.C.; Bau, R. (Univ. of Southern California, Los Angeles, CA (United States)); Mosher, H.S. (Stanford Univ., CA (United States)); Koetzle, T.F. (Brookhaven National Lab., Upton, NY (United States))

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanol-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH[sub 3])[sub 3] group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH[sub 3])[sub 3] groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2[sub 1] (monoclinic), a = 18.564(6) [angstrom], b = 7.713(2) [angstrom], c = 23.361(8) [angstrom], [beta] = 94.18(4)[degrees], V = 3336.0(5) [angstrom][sup 3], Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis). 49 refs., 7 figs., 2 tabs.

  17. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  18. Effect of heterogeneity of human population in cell radiosensitivity on the extrapolation of dose-response relationships to low doses

    International Nuclear Information System (INIS)

    Filyushkin, I.V.; Bragin, Yu.N.; Khandogina, E.K.

    1989-01-01

    Presented are the results of an investigation of the dose-response relationship for the yield of chromosome aberrations in peripheral blood lymphocytes of persons with some hereditary diseases which represent the high risk group with respect to the increased incidence of malignant tumors and decreased life span. Despite substantially different absolute radiosensitivities of chromosomes, the variations of the alpha/beta ratio determining the extrapolation of experimental dose-response relationships to low doses did not prove to be too high, the mean deviation from the control being 15%. This points to the possible practical use of the dose-response relationships averaged over the human population as a whole

  19. Determination of the contribution of livestock water ingestion to dose from the cow-milk pathway

    International Nuclear Information System (INIS)

    Ikenberry, T.A.

    1992-12-01

    As part of the Hanford Environmental Dose Reconstruction (HEDR) Project, a series of calculations has been undertaken to evaluate the absolute and relative contribution of different exposure pathways to thyroid doses that may have been received by individuals living in the vicinity of the Hanford Site. These evaluations include some pathways that were included in the Phase I air-pathway dose evaluations (HEDR staff 1991, page xx), as well as other potential exposure pathways being evaluated for possible inclusion in the future HEDR modeling efforts. This calculation (002) examined the possible doses that may have been received by individuals who drank milk from cows that drank from sources of water (stock tanks and farm ponds) exposed to iodine-131 in the atmosphere during 1945

  20. Invariant and Absolute Invariant Means of Double Sequences

    Directory of Open Access Journals (Sweden)

    Abdullah Alotaibi

    2012-01-01

    Full Text Available We examine some properties of the invariant mean, define the concepts of strong σ-convergence and absolute σ-convergence for double sequences, and determine the associated sublinear functionals. We also define the absolute invariant mean through which the space of absolutely σ-convergent double sequences is characterized.

  1. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources; Aplicabilidade de um prototipo para determinacao da dose absorvida utilizando equipamentos de braquiterapia com fontes de IR-192

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila, E-mail: vlsouza@cnen.gov.br, E-mail: mayaradqf@hotmail.com, E-mail: rodriguesss@hootmail.com, E-mail: waldecy@cnen.gov.br, E-mail: riziakeila@hotmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose.

  2. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  3. Cytogenetic, cytotoxic and GC-MS studies on concrete and absolute oils from Taif rose, Saudi Arabia.

    Science.gov (United States)

    Hagag, Heba A; Bazaid, Salih A; Abdel-Hameed, El-Sayed S; Salman, Mahmood

    2014-12-01

    Taif rose (Rosa damascena trigintipetala Dieck) is a sort of damask rose, which is considered as one of the most important economic products of Taif. In this study, the authors investigated the possible cytotoxic, genotoxic, antimutagenic and anticancer effect of concrete and absolute rose oils. The results showed that both concrete and absolute rose oils were cytotoxically and genotoxically safe at a dose of 10 μg/ml when tested on cultures of normal human blood lymphocytes. Also, the results showed significant antimutagenic activity at p oil at the same dose level when tested on cultures of normal human blood lymphocytes supplemented with 300 ng/ml mitomycin C (MMC). On the other hand, concrete and absolute oils exerted a cytotoxic activity against two kinds of human cancer cell lines: HepG2 and MCF7. Concrete oil showed cytotoxic activity against HepG2 and MCF7 with a half maximal inhibitory concentration (IC50) of 16.28 and 18.09 μg/ml, respectively, whereas absolute rose oil showed its cytotoxic activity against HepG2 and MCF7 with an IC50 of 24.94 and 19.69, respectively. From this study, it is concluded that concrete and absolute rose oils are cytotoxically and genotoxically safe at a dose of 10 μg/ml when tested on cultures of normal human blood lymphocytes. In addition, absolute oil has an antimutagenic activity at the same dose. Further investigations are needed to study the activity of higher doses of both oils in vitro and in vivo in experimental animals in order to evaluate the capability of using these oils as therapeutic for treatment of some kinds of cancers.

  4. Absolute measurement of a tritium standard

    International Nuclear Information System (INIS)

    Hadzisehovic, M.; Mocilnik, I.; Buraei, K.; Pongrac, S.; Milojevic, A.

    1978-01-01

    For the determination of a tritium absolute activity standard, a method of internal gas counting has been used. The procedure involves water reduction by uranium and zinc further the measurement of the absolute disintegration rate of tritium per unit of the effective volume of the counter by a compensation method. Criteria for the choice of methods and procedures concerning the determination and measurement of gaseous 3 H yield, parameters of gaseous hydrogen, sample mass of HTO and the absolute disintegration rate of tritium are discussed. In order to obtain gaseous sources of 3 H (and 2 H), the same reversible chemical reaction was used, namely, the water - uranium hydride - hydrogen system. This reaction was proved to be quantitative above 500 deg C by measuring the yield of the gas obtained and the absolute activity of an HTO standard. A brief description of the measuring apparatus is given, as well as a critical discussion of the brass counter quality and the possibility of obtaining equal working conditions at the counter ends. (T.G.)

  5. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  6. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  7. Determination of local absolute detection efficiency of a ceratron with 55Fe Auger electrons

    International Nuclear Information System (INIS)

    Mori, C.; Sugiyama, T.; Watanabe, T.

    1983-01-01

    The local absolute detection efficiency of a Ceratron (channel electron multiplier made of ceramics) was determined with collimated Mn K Auger electrons ( 5 keV) emitted from 55 Fe as a function of electron incident position and applied voltage. The local efficiency at the channel inlet did not depend so much on the applied voltage. The efficiency at the funnel increased with the applied voltage, while it was always lower than that at the channel inlet. (orig.)

  8. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  9. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    International Nuclear Information System (INIS)

    Hardy, A; Bostani, M; McMillan, K; Zankl, M; Cagnon, C; McNitt-Gray, M

    2016-01-01

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  10. TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, A; Bostani, M [University of California, Los Angeles, Los Angeles, CA (United States); McMillan, K [Mayo Clinic, Rochester, MN (United States); Zankl, M [Helmholtz Zentrum Munchen, Neuherberg (Germany); Cagnon, C [UCLA Medical Center, Los Angeles, CA (United States); McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical

  11. SU-F-T-566: Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Lu, S; Qin, Y; Huang, Y; Zhao, B; Liu, C; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of different dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

  12. Dose determination in radiotherapy for photon beams modified by static intensity modulators

    International Nuclear Information System (INIS)

    Castellanos Lopez, M.E.

    1998-01-01

    The static intensity modulators, used in radiotherapy, modify the spectral composition of the beam and lead to specific problems of the dose calculation. The aim of this work was to establish a three dimensional calculation, global and accurate, adapted to the primary-diffused separation algorithm and valid for any static modulator type. A theoretical study, experimentally verified, allowed the evaluation of the primary fluence, resulting from metallic sheets placed between photons beams of 6 to 23 MV nominal energy. It has been showed that the diffused, coming from the modulators, could be neglected for weak thickness and for the relative dose variation. In return it leads to significant variations of many % on the absolute dose and must be take into account for the bigger thicknesses. Corrective methods for the primary fluence have been proposed. From the energy spectra of the beam, the metallic modulator influence has been studied on the primary and diffused components of the dose and improvements of the calculation method have been proposed. These improvements are based on the modulator representation as a transmission matrix and on semi-empirical corrective factors. (A.L.B.)

  13. The use of absolute gravity data for the validation of Global Geopotential Models and for improving quasigeoid heights determined from satellite-only Global Geopotential Models

    Science.gov (United States)

    Godah, Walyeldeen; Krynski, Jan; Szelachowska, Malgorzata

    2018-05-01

    The objective of this paper is to demonstrate the usefulness of absolute gravity data for the validation of Global Geopotential Models (GGMs). It is also aimed at improving quasigeoid heights determined from satellite-only GGMs using absolute gravity data. The area of Poland, as a unique one, covered with a homogeneously distributed set of absolute gravity data, has been selected as a study area. The gravity anomalies obtained from GGMs were validated using the corresponding ones determined from absolute gravity data. The spectral enhancement method was implemented to overcome the spectral inconsistency in data being validated. The quasigeoid heights obtained from the satellite-only GGM as well as from the satellite-only GGM in combination with absolute gravity data were evaluated with high accuracy GNSS/levelling data. Estimated accuracy of gravity anomalies obtained from GGMs investigated is of 1.7 mGal. Considering omitted gravity signal, e.g. from degree and order 101 to 2190, satellite-only GGMs can be validated at the accuracy level of 1 mGal using absolute gravity data. An improvement up to 59% in the accuracy of quasigeoid heights obtained from the satellite-only GGM can be observed when combining the satellite-only GGM with absolute gravity data.

  14. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  15. A graphite calorimeter for absolute measurements of absorbed dose to water: application in medium-energy x-ray filtered beams.

    Science.gov (United States)

    Pinto, M; Pimpinella, M; Quini, M; D'Arienzo, M; Astefanoaei, I; Loreti, S; Guerra, A S

    2016-02-21

    The Italian National Institute of Ionizing Radiation Metrology (ENEA-INMRI) has designed and built a graphite calorimeter that, in a water phantom, has allowed the determination of the absorbed dose to water in medium-energy x-rays with generating voltages from 180 to 250 kV. The new standard is a miniaturized three-bodies calorimeter, with a disc-shaped core of 21 mm diameter and 2 mm thickness weighing 1.134 g, sealed in a PMMA waterproof envelope with air-evacuated gaps. The measured absorbed dose to graphite is converted into absorbed dose to water by means of an energy-dependent conversion factor obtained from Monte Carlo simulations. Heat-transfer correction factors were determined by FEM calculations. At a source-to-detector distance of 100 cm, a depth in water of 2 g cm(-2), and at a dose rate of about 0.15 Gy min(-1), results of calorimetric measurements of absorbed dose to water, D(w), were compared to experimental determinations, D wK, obtained via an ionization chamber calibrated in terms of air kerma, according to established dosimetry protocols. The combined standard uncertainty of D(w) and D(wK) were estimated as 1.9% and 1.7%, respectively. The two absorbed dose to water determinations were in agreement within 1%, well below the stated measurement uncertainties. Advancements are in progress to extend the measurement capability of the new in-water-phantom graphite calorimeter to other filtered medium-energy x-ray qualities and to reduce the D(w) uncertainty to around 1%. The new calorimeter represents the first implementation of in-water-phantom graphite calorimetry in the kilovoltage range and, allowing independent determinations of D(w), it will contribute to establish a robust system of absorbed dose to water primary standards for medium-energy x-ray beams.

  16. Absolute isotopic abundances of Ti in meteorites

    International Nuclear Information System (INIS)

    Niederer, F.R.; Papanastassiou, D.A.; Wasserburg, G.J.

    1985-01-01

    The absolute isotope abundance of Ti has been determined in Ca-Al-rich inclusions from the Allende and Leoville meteorites and in samples of whole meteorites. The absolute Ti isotope abundances differ by a significant mass dependent isotope fractionation transformation from the previously reported abundances, which were normalized for fractionation using 46 Ti/ 48 Ti. Therefore, the absolute compositions define distinct nucleosynthetic components from those previously identified or reflect the existence of significant mass dependent isotope fractionation in nature. We provide a general formalism for determining the possible isotope compositions of the exotic Ti from the measured composition, for different values of isotope fractionation in nature and for different mixing ratios of the exotic and normal components. The absolute Ti and Ca isotopic compositions still support the correlation of 50 Ti and 48 Ca effects in the FUN inclusions and imply contributions from neutron-rich equilibrium or quasi-equilibrium nucleosynthesis. The present identification of endemic effects at 46 Ti, for the absolute composition, implies a shortfall of an explosive-oxygen component or reflects significant isotope fractionation. Additional nucleosynthetic components are required by 47 Ti and 49 Ti effects. Components are also defined in which 48 Ti is enhanced. Results are given and discussed. (author)

  17. Dose measurement of ion implanted silicon by RBS technique

    International Nuclear Information System (INIS)

    Kamawanna, Teerasak; Intarasiri, Saweat; Prapunsri, Chowunchun; Thongleurm, Chome; Maleepatra, Saenee; Singkarat, Somsorn

    2003-10-01

    Surface modification can be achieved by ion implantation. This study used a 1 mm thick silicon wafer as a target which was implanted with Ar+ at 80 keV. The degree of the modification depends on both the ion energy and the implanted dose. The distribution of argon in the silicon substrate and the absolute implanted dose can be measured by using Rutherford Backscattering Spectrometry (RBS). These investigations utilized a 1.7 MV Tandetron accelerator system at Chiang Mai University. The dose determination by a direct calculation is in agreement with the simulation by the SIMNRA code

  18. Dose Rate Determination from Airborne Gamma-ray Spectra

    DEFF Research Database (Denmark)

    Bargholz, Kim

    1996-01-01

    The standard method for determination of ground level dose rates from airborne gamma-ray is the integral count rate which for a constant flying altitude is assumed proportional to the dose rate. The method gives reasonably results for natural radioactivity which almost always has the same energy...

  19. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  20. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  1. Redetermination and absolute configuration of atalaphylline

    Directory of Open Access Journals (Sweden)

    Hoong-Kun Fun

    2010-02-01

    Full Text Available The title acridone alkaloid [systematic name: 1,3,5-trihydroxy-2,4-bis(3-methylbut-2-enylacridin-9(10H-one], C23H25NO4, has previously been reported as crystallizing in the chiral orthorhombic space group P212121 [Chantrapromma et al. (2010. Acta Cryst. E66, o81–o82] but the absolute configuration could not be determined from data collected with Mo radiation. The absolute configuration has now been determined by refinement of the Flack parameter with data collected using Cu radiation. All features of the molecule and its crystal packing are similar to those previously described.

  2. Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Samantha, E-mail: Samantha.warren@oncology.ox.ac.uk [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Panettieri, Vanessa [William Buckland Radiotherapy Centre, Alfred Hospital, Commercial Road, Melbourne (Australia); Panakis, Niki; Bates, Nicholas [Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom); Lester, Jason F. [Velindre Cancer Centre, Velindre Road, Whitchurch, Cardiff (United Kingdom); Jain, Pooja [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Landau, David B. [Department of Radiotherapy, Guy' s and St. Thomas' NHS Foundation Trust, London (United Kingdom); Nahum, Alan E.; Mayles, W. Philip M. [Clatterbridge Cancer Centre, Clatterbridge Road, Wirral (United Kingdom); Fenwick, John D. [Department of Oncology, Gray Institute of Radiation Oncology and Biology, University of Oxford, Oxford (United Kingdom); Oxford Cancer Centre, Oxford University Hospitals, Oxford (United Kingdom)

    2014-04-01

    Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

  3. SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Cui, G; Ha, J; Zhou, S; Cui, J; Shiu, A [University Southern California, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validated by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.

  4. Method and apparatus for determining the dose value of neutrons

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Piesch, E.

    1976-01-01

    A method is provided for determining the dose value of neutrons leaving a body as thermal and intermediate neutrons after having been scattered in the body. A first dose value of thermal and intermediate neutrons is detected on the surface of the body by means of a first detector for neutrons which is shielded against thermal and intermediate neutrons not emerging from the body. A second detector is used to measure a second dose value of the thermal and intermediate neutrons not emerging from the body. A first correction factor based on the first and second values is obtained from a calibration diagram and is applied to the first dose value to determine a first corrected first dose value. 21 Claims, 6 Drawing Figures

  5. Cumulative cisplatin dose in concurrent chemoradiotherapy for head and neck cancer : A systematic review

    NARCIS (Netherlands)

    Strojan, Primoz; Vermorken, Jan B.; Beitler, Jonathan J.; Saba, Nabil F.; Haigentz, Missak; Bossi, Paolo; Worden, Francis P.; Langendijk, Johannes A.; Eisbruch, Avraham; Mendenhall, William M.; Lee, Anne W. M.; Harrison, Louis B.; Bradford, Carol R.; Smee, Robert; Silver, Carl E.; Rinaldo, Alessandra; Ferlito, Alfio

    Background. The optimal cumulative dose and timing of cisplatin administration in various concurrent chemoradiotherapy protocols for nonmetastatic head and neck squamous cell carcinoma (HNSCC) has not been determined. Methods. The absolute survival benefit at 5 years of concurrent chemoradiotherapy

  6. A novel setup for the determination of absolute cross sections for low-energy electron induced strand breaks in oligonucleotides - The effect of the radiosensitizer 5-fluorouracil

    International Nuclear Information System (INIS)

    Rackwitz, J.; Rankovic, M.L.; Milosavljevic, A.R.; Bald, I.

    2017-01-01

    Low-energy electrons (LEEs) play an important role in DNA radiation damage. Here we present a method to quantify LEE induced strand breakage in well-defined oligonucleotide single strands in terms of absolute cross sections. An LEE irradiation setup covering electron energies <500 eV is constructed and optimized to irradiate DNA origami triangles carrying well-defined oligonucleotide target strands. Measurements are presented for 10.0 and 5.5 eV for different oligonucleotide targets. The determination of absolute strand break cross sections is performed by atomic force microscopy analysis. An accurate fluence determination ensures small margins of error of the determined absolute single strand break cross sections σ SSB . In this way, the influence of sequence modification with the radiosensitive 5-Fluorouracil ( 5F U) is studied using an absolute and relative data analysis. We demonstrate an increase in the strand break yields of 5F U containing oligonucleotides by a factor of 1.5 to 1.6 compared with non-modified oligonucleotide sequences when irradiated with 10 eV electrons. (authors)

  7. Determination of environmental radioactivity for dose assessment

    International Nuclear Information System (INIS)

    Nakoaka, A.; Fukushima, M.; Takagi, S.

    1980-01-01

    A method was devised to determine detection limits for radioactivity in environmental samples. The method is based on the 5 mrem/yr whole-body dose objective established by the Japan Atomic Enerty Commission and is valid for assessing the internal dose from radionuclides in the environment around a nuclear facility. Eleven samples and 15 radionuclides were considered. Internal dose was assumed to be one-half of the total dose (5 mrem/yr) and was assessed using the critical pathway method. Needed detection limits (NDLs) were established to confirm the dose of 5 mrem/yr when there was more than one radionuclide per sample. The NDLs for γ-emitters were 10 -5 pCi/l. for air; 10 -3 pCi/l. for seawater; 10 -1 pCi/l. for drinking water; 10 0 pCi/kg for vegetables and fish; 10 0 pCi/l. for milk; and 10 1 pCi/kg for molluscs, crustaceans, seaweeds, soil and submarine sediments. The NDLs for β-emitters were 1-1/100 of those for γ-emitters. (author)

  8. Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Lillo, R.; Massardo, T.; Jofre, M.J.

    2002-01-01

    Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine. Introduction: The coadyuvant treatment with 131 I had proven to be useful in patients with differentiated thyroid carcinoma (DTC). Due to the physical characteristics of this radioisotope these patients must be absolutely isolated in order to reduce the radioactive exposure to other individuals. The aim of the study was to determine the time required to reach the maximum permissible radiation exposure level (0,25mR/h) to general public. Material between August 1999 and May 2000, 30 patients with DTC diagnosis in the University of Chile Clinical Hospital Nuclear Medicine Centre were studied, 25 women (83%) and 5 men (17%), mean age 45 years old (15-71 range). Tumoral histology was 86% papillary and 14% follicular types. Thirty one doses of 131 I were administered ( one patient received 2 doses): 24 of 100 mCi (77%), 5 of 150 mCi (16%) and 2 of 200 mCi (7%); afterwards the 1 m exposition rate in air was measured at neck level with a Geiger-Mueller detector. The procedure was repeated on day 4 and every day following until the predicted radiation exposure levels were reached. Results: The average exposure rate at day 0 ( after given the radiopharmaceutical) was 20,12 mR/h (4-32 range). At day 4 the average rate was 0,21 mR/h (0,08-0,34 ), and 61% (n=19) of the patients reached 0,25 mR/h within that day. On day 5 10% (n=3) reached 0,25 mR/h (0,25-0,26), on day 6 16% (n=5) reached 0,25 mR/h (0,2-0,28), on day 7 6% (n=2) reached 0,39 mR/h (0,25-0,48) and the remaining 7% on day 13 and day 17 (n=2). Conclusion After a treatment dose of 131 iodine over 60% of the cases can finish the isolation on day 4, and 90% on day 7. The measurement of 131 I uptake after 24 hours will help to determine the evolution of post treatment levels

  9. Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P [University of Chile Clinical Hospital Nuclear Medicine Centre, Santiago (Chile); Military Hospital Nuclear Medicine Department , Santiago (Chile); Lillo, R; Massardo, T [University of Chile Clinical Hospital Nuclear Medicine Centre, Santiago (Chile); Jofre, M J [Military Hospital Nuclear Medicine Department, Santiago (Chile)

    2002-09-01

    Isolation time determination of patients with differentiated thyroid carcinoma treated with therapeutic doses of 131 radioiodine. Introduction: The coadyuvant treatment with 131 I had proven to be useful in patients with differentiated thyroid carcinoma (DTC). Due to the physical characteristics of this radioisotope these patients must be absolutely isolated in order to reduce the radioactive exposure to other individuals. The aim of the study was to determine the time required to reach the maximum permissible radiation exposure level (0,25mR/h) to general public. Material between August 1999 and May 2000, 30 patients with DTC diagnosis in the University of Chile Clinical Hospital Nuclear Medicine Centre were studied, 25 women (83%) and 5 men (17%), mean age 45 years old (15-71 range). Tumoral histology was 86% papillary and 14% follicular types. Thirty one doses of 131 I were administered ( one patient received 2 doses): 24 of 100 mCi (77%), 5 of 150 mCi (16%) and 2 of 200 mCi (7%); afterwards the 1 m exposition rate in air was measured at neck level with a Geiger-Mueller detector. The procedure was repeated on day 4 and every day following until the predicted radiation exposure levels were reached. Results: The average exposure rate at day 0 ( after given the radiopharmaceutical) was 20,12 mR/h (4-32 range). At day 4 the average rate was 0,21 mR/h (0,08-0,34 ), and 61% (n=19) of the patients reached 0,25 mR/h within that day. On day 5 10% (n=3) reached 0,25 mR/h (0,25-0,26), on day 6 16% (n=5) reached 0,25 mR/h (0,2-0,28), on day 7 6% (n=2) reached 0,39 mR/h (0,25-0,48) and the remaining 7% on day 13 and day 17 (n=2). Conclusion After a treatment dose of 131 iodine over 60% of the cases can finish the isolation on day 4, and 90% on day 7. The measurement of 131 I uptake after 24 hours will help to determine the evolution of post treatment levels.

  10. Absolute measurement of {beta} activities and application to the determination of neutronic densities; Mesure absolue d'activites {beta} et application a la determination des densites neutronique

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, R. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1951-01-15

    M. Berthelot, to my entrance to the ''Commissariat a l 'Energie Atomique'', proposed me to study the absolute measurement of neutron densities. Very quickly the problem of the absolute activity of {beta} sources became the central object of this work. In a first part, we will develop the methods of absolute determination for {beta} activities. The use of a 4{pi} counter permits to get the absolute activity of all beta radioactive source, susceptible to be put as thin leaf and of period superior than some minutes. The method is independent of the spectra of the measured radioelement. we will describe in the second part some applications which use neutron densities measurement, neutron sources intensities and ratio of cross sections of capture of thermal neutrons. (M.B.) [French] M. Berthelot, a mon entree au ''Commissariat a l 'Energie Atomique'', m'a propose d'etudier la mesure absolue des densites neutroniques. Tres rapidement le probleme de l'activite absolue des sources beta est devenu l'objet central de ce travail. Dans une premiere partie, on abordera les methodes de determination absolue des activites beta. L'utilisation d'un compteur 4{pi} permet d 'obtenir l'activite absolue de toute source radioactive beta, susceptible d'etre mise sous forme de feuille mince et de periode superieure a quelques minutes. La methode est independante du spectre du radioelement mesure. On decrira dans la seconde partie quelques applications a des mesures de densites neutroniques, d'intensites de sources de neutrons et de rapport de sections efficaces de capture de neutrons thermiques. (M.B.)

  11. Advancing Absolute Calibration for JWST and Other Applications

    Science.gov (United States)

    Rieke, George; Bohlin, Ralph; Boyajian, Tabetha; Carey, Sean; Casagrande, Luca; Deustua, Susana; Gordon, Karl; Kraemer, Kathleen; Marengo, Massimo; Schlawin, Everett; Su, Kate; Sloan, Greg; Volk, Kevin

    2017-10-01

    We propose to exploit the unique optical stability of the Spitzer telescope, along with that of IRAC, to (1) transfer the accurate absolute calibration obtained with MSX on very bright stars directly to two reference stars within the dynamic range of the JWST imagers (and of other modern instrumentation); (2) establish a second accurate absolute calibration based on the absolutely calibrated spectrum of the sun, transferred onto the astronomical system via alpha Cen A; and (3) provide accurate infrared measurements for the 11 (of 15) highest priority stars with no such data but with accurate interferometrically measured diameters, allowing us to optimize determinations of effective temperatures using the infrared flux method and thus to extend the accurate absolute calibration spectrally. This program is integral to plans for an accurate absolute calibration of JWST and will also provide a valuable Spitzer legacy.

  12. Absolute risk, absolute risk reduction and relative risk

    Directory of Open Access Journals (Sweden)

    Jose Andres Calvache

    2012-12-01

    Full Text Available This article illustrates the epidemiological concepts of absolute risk, absolute risk reduction and relative risk through a clinical example. In addition, it emphasizes the usefulness of these concepts in clinical practice, clinical research and health decision-making process.

  13. Fast neutron radiation inactivation of Bacillus subtilis: Absorbed dose determination

    International Nuclear Information System (INIS)

    Song Lingli; Zheng Chun; Ai Zihui; Li Junjie; Dai Shaofeng

    2011-01-01

    In this paper, fast neutron inactivation effects of Bacillus subtilis were investigated with fission fast neutrons from CFBR-II reactor of INPC (Institute of Nuclear Physics and Chemistry) and mono-energetic neutrons from the Van de Graaff accelerator at Peking University. The method for determining the absorbed dose in the Bacillus subtilis suspension contained in test tubes is introduced. The absorbed dose, on account of its dependence on the volume and the form of confined state, was determined by combined experiments and Monte Carlo method. Using the calculation results of absorbed dose, the fast neutron inactivation effects on Bacillus subtilis were studied. The survival rates and absorbed dose curve was constructed. (authors)

  14. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  15. Incorrect Weighting of Absolute Performance in Self-Assessment

    Science.gov (United States)

    Jeffrey, Scott A.; Cozzarin, Brian

    Students spend much of their life in an attempt to assess their aptitude for numerous tasks. For example, they expend a great deal of effort to determine their academic standing given a distribution of grades. This research finds that students use their absolute performance, or percentage correct as a yardstick for their self-assessment, even when relative standing is much more informative. An experiment shows that this reliance on absolute performance for self-evaluation causes a misallocation of time and financial resources. Reasons for this inappropriate responsiveness to absolute performance are explored.

  16. A practical approach to determine dose metrics for nanomaterials.

    Science.gov (United States)

    Delmaar, Christiaan J E; Peijnenburg, Willie J G M; Oomen, Agnes G; Chen, Jingwen; de Jong, Wim H; Sips, Adriënne J A M; Wang, Zhuang; Park, Margriet V D Z

    2015-05-01

    Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking. The discussion regarding the most adequate dose metric for nanomaterials clearly needs a systematic, unbiased approach to determine the most appropriate dose metric for nanomaterials. In the present study, the authors propose such an approach and apply it to results from in vitro and in vivo experiments with silver and silica nanomaterials. The proposed approach is shown to provide a convenient tool to systematically investigate and interpret dose metrics of nanomaterials. Recommendations for study designs aimed at investigating dose metrics are provided. © 2015 SETAC.

  17. Determination of the radiation dose to the body due to external radiation

    International Nuclear Information System (INIS)

    Drexler, G.; Eckerl, H.

    1985-01-01

    Section 63 of the Radiation Protection Ordinance defines the basic requirement, determination of radiation dose to the body. The determination of dose equivalents for the body is the basic step in practical monitoring of dose equivalents or dose limits with regard to individuals or population groups, both for constant or varying conditions of exposure. The main field of monitoring activities is the protection of persons occupationally exposed to ionizing radiation. Conversion factors between body doses and radiation quantities are explained. (DG) [de

  18. Determination of the absolute K through O conversion coefficients of the 80-keV M4 transition in /sup 193/Ir/sup m/

    International Nuclear Information System (INIS)

    Lindner, M.; Gunnink, R.; Nagle, R.J.

    1987-01-01

    We produced carrier-free, nearly isotopically pure /sup 193/Ir/sup m/ from thermal-neutron irradiation of /sup 192/Os. From studies of the conversion-electron spectrum, the photon spectrum, and the absolute counting rates, we determined the absolute K, L1, L2, L3, M1, M3, M5, N, and O+P conversion coefficients for the first time. With possibly one exception, these values agree closely with theoretical calculations. The value for the energy of the unconverted gamma ray was found to be 80.22 +- 0.02 keV. The half-life for /sup 193/Ir/sup m/ determined by absolute electron counting in a proportional counter of 100% counting efficiency (4πβ) was found to be 10.53 +- 0.04 d. We have determined the L 1 subshell fluorescence yield, ω 1 , to be 0.120 +- 0.003 for iridium. Based upon our measurements of initial and final L subshell vacancies together with a best-fit literature value for ω 2 , we have found a plausible value for the Coster-Kronig coefficient f/sub 12/ to be 0.091 +- 0.011

  19. Investigate the capability of INAA absolute method to determine the concentrations of 238U and 232Th in rock samples

    International Nuclear Information System (INIS)

    Alnour, I.A.

    2014-01-01

    This work aimed to study the capability of INAA absolute method in determining the elemental concentration of 238 U and 232 Th in the rock samples. The INAA absolute method was implemented in PUSPATI TRIGA Mark II research reactor, Malaysian Nuclear Agency (NM). The accuracy of INAA absolute method was performed by analyzing the IAEA certified reference material (CRM) Soil-7. The analytical results showed the deviations between experimental and certified values were mostly less than 10 % with Z-score in most cases less than 1. In general, the results of analysed CRM Soil-7 show a good agreement between certified and experimental results which mean that the INAA absolute method can be used accurately for elemental analysis of uranium and thorium in various types of samples. The concentration of 238 U and 232 Th ranged from 1.77 to 24.25 and 0.88 to 95.50 ppm respectively. The highest value of 238 U and 232 Th was recorded for granite rock sample G17 of 238 U and sample G9 of 232 Th, whereas the lower value was 1.77 ppm of 238 U recorded in sandstone rock and 0.88 ppm of 232 Th for gabbro. Moreover, a comparison of the 238 U and 232 Th results obtained by the INAA absolute method shows an acceptable level of consistency with those obtained by the INAA relative method. (author)

  20. Absolute determination of zero-energy phase shifts for multiparticle single-channel scattering: Generalized Levinson theorem

    International Nuclear Information System (INIS)

    Rosenberg, L.; Spruch, L.

    1996-01-01

    Levinson close-quote s theorem relates the zero-energy phase shift δ for potential scattering in a given partial wave l, by a spherically symmetric potential that falls off sufficiently rapidly, to the number of bound states of that l supported by the potential. An extension of this theorem is presented that applies to single-channel scattering by a compound system initially in its ground state. As suggested by Swan [Proc. R. Soc. London Ser. A 228, 10 (1955)], the extended theorem differs from that derived for potential scattering; even in the absence of composite bound states δ may differ from zero as a consequence of the Pauli principle. The derivation given here is based on the introduction of a continuous auxiliary open-quote open-quote length phase close-quote close-quote η, defined modulo π for l=0 by expressing the scattering length as A=acotη, where a is a characteristic length of the target. Application of the minimum principle for the scattering length determines the branch of the cotangent curve on which η lies and, by relating η to δ, an absolute determination of δ is made. The theorem is applicable, in principle, to single-channel scattering in any partial wave for e ± -atom and nucleon-nucleus systems. In addition to a knowledge of the number of composite bound states, information (which can be rather incomplete) concerning the structure of the target ground-state wave function is required for an explicit, absolute, determination of the phase shift δ. As for Levinson close-quote s original theorem for potential scattering, no additional information concerning the scattering wave function or scattering dynamics is required. copyright 1996 The American Physical Society

  1. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    CERN Document Server

    Folz, E

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose.

  2. A single-aliquot OSL protocol using bracketing regenerative doses to accurately determine equivalent doses in quartz

    International Nuclear Information System (INIS)

    Folz, Elise; Mercier, Norbert

    1999-01-01

    In most cases, sediments show inherent heterogeneity in their luminescence behaviours and bleaching histories, and identical aliquots are not available: single-aliquot determination of the equivalent dose (ED) is then the approach of choice and the advantages of using regenerative protocols are outlined. Experiments on five laboratory bleached and dosed quartz samples, following the protocol described by Murray and Roberts (1998. Measurement of the equivalent dose in quartz using a regenerative-dose single aliquot protocol. Radiation Measurements 27, 171-184), showed the hazards of using a single regeneration dose: a 10% variation in the regenerative dose yielded some equivalent dose estimates that differed from the expected value by more than 5%. A protocol is proposed that allows the use of different regenerative doses to bracket the estimated equivalent dose. The measured ED is found to be in excellent agreement with the known value when the main regeneration dose is within 10% of the true equivalent dose

  3. Does Absolute Synonymy exist in Owere-Igbo? | Omego | AFRREV ...

    African Journals Online (AJOL)

    Among Igbo linguistic researchers, determining whether absolute synonymy exists in Owere–Igbo, a dialect of the Igbo language predominantly spoken by the people of Owerri, Imo State, Nigeria, has become a thorny issue. While some linguistic scholars strive to establish that absolute synonymy exists in the lexical ...

  4. Determination of tolerance dose uncertainties and optimal design of dose response experiments with small animal numbers

    International Nuclear Information System (INIS)

    Karger, C.P.; Hartmann, G.H.

    2001-01-01

    Background: Dose response experiments aim to determine the complication probability as a function of dose. Adjusting the parameters of the frequently used dose response model P(D)=1/[1+(D 50 /D) k ] to the experimental data, 2 intuitive quantities are obtained: The tolerance dose D 50 and the slope parameter k. For mathematical reasons, however, standard statistic software uses a different set of parameters. Therefore, the resulting fit parameters of the statistic software as well as their standard errors have to be transformed to obtain D 50 and k as well as their standard errors. Material and Methods: The influence of the number of dose levels on the uncertainty of the fit parameters is studied by a simulation for a fixed number of animals. For experiments with small animal numbers, statistical artifacts may prevent the determination of the standard errors of the fit parameters. Consequences on the design of dose response experiments are investigated. Results: Explicit formulas are presented, which allow to calculate the parameters D 50 and k as well as their standard errors from the output of standard statistic software. The simulation shows, that the standard errors of the resulting parameters are independent of the number of dose levels, as long as the total number of animals involved in the experiment, remains constant. Conclusion: Statistical artifacts in experiments containing small animal numbers may be prevented by an adequate design of the experiment. For this, it is suggested to select a higher number of dose levels, rather than using a higher number of animals per dose level. (orig.) [de

  5. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  6. The determination of effective doses from the intake of tritiated water

    International Nuclear Information System (INIS)

    1987-08-01

    To comply with the regulatory requirements relating to the dose from exposures to tritiated water (HTO), Atomic Energy Control Board (AECB) licensees currently measure tritium concentration in urine to determine whole body dose. This approach has been based on the consideration that the time-integrated tritium concentration (which is proportional to accumulated dose) in any organ from urine concentrations are always conservative. The International Commission on Radiological Protection (ICRP) recommends that the average soft tissue dose be used to determine effective dose equivalents for HTO exposures. The ICRP also recommends that only the retention in body water be considered when committed doses from HTO exposures are calculated; this recommendation is based on the consideration that the errors introduced by neglecting the long-lived tritium component (those tritium atoms retained in organic molecules of the body cells) are small (only of the order of 10% of the committed dose equivalent to the whole body). The AECB position is presented in the following regulatory policy statement

  7. Absolute luminosity measurements with the LHCb detector at the LHC

    CERN Document Server

    Aaij, R; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amhis, Y; Anderson, J; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Arrabito, L; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Bailey, D S; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bates, A; Bauer, C; Bauer, Th; Bay, A; Bediaga, I; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blanks, C; Blouw, J; Blusk, S; Bobrov, A; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Brisbane, S; Britsch, M; Britton, T; Brook, N H; Brown, H; Büchler-Germann, A; Burducea, I; Bursche, A; Buytaert, J; Cadeddu, S; Caicedo Carvajal, J M; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Charles, M; Charpentier, Ph; Chiapolini, N; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Collins, P; Constantin, F; Conti, G; Contu, A; Cook, A; Coombes, M; Corti, G; Cowan, G A; Currie, R; D'Almagne, B; D'Ambrosio, C; David, P; De Bonis, I; De Capua, S; De Cian, M; De Lorenzi, F; De Miranda, J M; De Paula, L; De Simone, P; Decamp, D; Deckenhoff, M; Degaudenzi, H; Deissenroth, M; Del Buono, L; Deplano, C; Deschamps, O; Dettori, F; Dickens, J; Dijkstra, H; Diniz Batista, P; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Eames, C; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisele, F; Eisenhardt, S; Ekelhof, R; Eklund, L; Elsasser, Ch; d'Enterria, D G; Esperante Pereira, D; Estève, L; Falabella, A; Fanchini, E; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Fernandez Albor, V; Ferro-Luzzi, M; Filippov, S; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Frank, M; Frei, C; Frosini, M; Furcas, S; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garnier, J-C; Garofoli, J; Garra Tico, J; Garrido, L; Gaspar, C; Gauvin, N; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Gregson, S; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Haefeli, G; Haen, C; Haines, S C; Hampson, T; Hansmann-Menzemer, S; Harji, R; Harnew, N; Harrison, J; Harrison, P F; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hofmann, W; Holubyev, K; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Huston, R S; Hutchcroft, D; Hynds, D; Iakovenko, V; Ilten, P; Imong, J; Jacobsson, R; Jaeger, A; Jahjah Hussein, M; Jans, E; Jansen, F; Jaton, P; Jean-Marie, B; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kandybei, S; Karacson, M; Karbach, T M; Keaveney, J; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kim, Y M; Knecht, M; Koblitz, S; Koppenburg, P; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kruzelecki, K; Kucharczyk, M; Kukulak, S; Kumar, R; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Li, L; Li Gioi, L; Lieng, M; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Luisier, J; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Magnin, J; Malde, S; Mamunur, R M D; Manca, G; Mancinelli, G; Mangiafave, N; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinez Santos, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Matveev, M; Maurice, E; Maynard, B; Mazurov, A; McGregor, G; McNulty, R; Mclean, C; Meissner, M; Merk, M; Merkel, J; Messi, R; Miglioranzi, S; Milanes, D A; Minard, M-N; Monteil, S; Moran, D; Morawski, P; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Musy, M; Mylroie-Smith, J; Naik, P; Nakada, T; Nandakumar, R; Nardulli, J; Nasteva, I; Nedos, M; Needham, M; Neufeld, N; Nguyen-Mau, C; Nicol, M; Nies, S; Niess, V; Nikitin, N; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Pal, B; Palacios, J; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Paterson, S K; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petrella, A; Petrolini, A; Pie Valls, B; Pietrzyk, B; Pilar, T; Pinci, D; Plackett, R; Playfer, S; Plo Casasus, M; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; du Pree, T; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Rinnert, K; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodrigues, F; Rodriguez Perez, P; Rogers, G J; Roiser, S; Romanovsky, V; Rouvinet, J; Ruf, T; Ruiz, H; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santinelli, R; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schleich, S; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shao, B; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skottowe, H P; Skwarnicki, T; Smith, A C; Smith, N A; Sobczak, K; Soler, F J P; Solomin, A; Soomro, F; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Styles, N; Subbiah, V K; Swientek, S; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Topp-Joergensen, S; Tran, M T; Tsaregorodtsev, A; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urquijo, P; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Vervink, K; Viaud, B; Videau, I; Vilasis-Cardona, X; Visniakov, J; Vollhardt, A; Voong, D; Vorobyev, A; Voss, H; Wacker, K; Wandernoth, S; Wang, J; Ward, D R; Webber, A D; Websdale, D; Whitehead, M; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Witzeling, W; Wotton, S A; Wyllie, K; Xie, Y; Xing, F; Yang, Z; Young, R; Yushchenko, O; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhong, L; Zverev, E; Zvyagin, A

    2012-01-01

    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic ``van der Meer scan'' method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5\\% in the absolute lumi...

  8. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  9. Absolute determination of 75Se for international comparison of activity measurements

    International Nuclear Information System (INIS)

    Iglicki, F.A.; Arenillas, P.A.; Furnari, J.C.

    1993-01-01

    An international intercomparison of absolute activity measurements of a solution of Se-75, organized by the Bureau International des Poids et Mesures, France, in 1992, has been carried out. The methodology and results are presented. Source preparation, experimental techniques and measurement system are described. (author). 2 refs

  10. Encasing the Absolutes

    Directory of Open Access Journals (Sweden)

    Uroš Martinčič

    2014-05-01

    Full Text Available The paper explores the issue of structure and case in English absolute constructions, whose subjects are deduced by several descriptive grammars as being in the nominative case due to its supposed neutrality in terms of register. This deduction is countered by systematic accounts presented within the framework of the Minimalist Program which relate the case of absolute constructions to specific grammatical factors. Each proposal is shown as an attempt of analysing absolute constructions as basic predication structures, either full clauses or small clauses. I argue in favour of the small clause approach due to its minimal reliance on transformations and unique stipulations. Furthermore, I propose that small clauses project a singular category, and show that the use of two cases in English absolute constructions can be accounted for if they are analysed as depictive phrases, possibly selected by prepositions. The case of the subject in absolutes is shown to be a result of syntactic and non-syntactic factors. I thus argue in accordance with Minimalist goals that syntactic case does not exist, attributing its role in absolutes to other mechanisms.

  11. Dose Determination of Activated Charcoal in Management of ...

    African Journals Online (AJOL)

    measured by high performance liquid chromatography (HPLC) for dose determination of activated ... paracetamol, benzodiazepines and alcohol [11]. .... Stability. The stability (short term) of standard and amitriptyline sample solutions was ...

  12. Determination of the absorbed dose and dose-distribution in water for low- and medium-energetic photons

    International Nuclear Information System (INIS)

    Bultman, J.H.

    1990-05-01

    The methods to determine the absorbed dose to water for low and medium energy photons were studied. Large differences between the results of these methods exists. So, a research proposition has been made to explain these differences. The goal of this research will be the development of a method to determine the absorbed dose below approximately 400 keV with an ionization chamber calibrated at 60 Co gamma radiation. To explain the differences between the set of methods, some causes were proposed, like the influence of the ionisation chamber on the measurement in water. Also, some methods to determine the factors are proposed. (author). 29 refs

  13. Determination of the total indicative dose in drinking and mineral waters

    International Nuclear Information System (INIS)

    Flesch, K.; Schulz, H.; Knappik, R.; Koehler, M.

    2006-01-01

    In Europe and Germany administrative regulations exist for the surveillance of the total indicative dose of water supplied for human consumption. This parameter, which cannot be analyzed directly, has to be calculated using nuclide specific activity concentration and age specific dose conversion factors and consumption rates. Available calculation methods differ regarding the used radionuclides, consumption rates and whether they use age specific dose conversion factors or not. In Germany administrative guidelines for the determination of the total indicative dose are still not available. As they have analyzed a large number of waters in the past, the authors derive a praxis orientated concept for the determination of the total indicative dose which respects radiological, analytical and hydrochemical aspects as well. Finally it is suggested to handle sparkling waters in the same manner as drinking waters. (orig.)

  14. Determination of organ doses in radiographic imaging and diagnostic radiology

    International Nuclear Information System (INIS)

    Rathjen, M.

    1981-01-01

    Earlier publications on diagnostic radiation exposure commonly presented data on the gonadal dose. This emphasis on the genetic radiation risk is no longer valid in view of recent radiobiological findings; equal attention should be paid to the somatic radiation risk which is manifested by the induction of malignant neoplasms, e.g. in the lungs, red bone marrow, thyroid and female breast (ICRP 26). The permissible radiation doses for these organs and the gonals for routine diagnostic radiology are determined. A formula is established on the basis of terms from relevant publications (e.g. open-air dose, backscattering factor) and from the author's own measurements in an Alderson-Rando phantom (depth dose curves, dose decrements). The measurements were carried out using CaP 2 thermoluminescence dosemeters, and the organ doses for the various techniques of X-ray examination were calculated by computer. Calculations of this type will enable the radiologist to determine the patient exposure quickly and easily from the records kept according to Sect. 29 of the X-ray Ordinance. Experimental value from relevant publications are compared with the author's own results. (orig./HP) [de

  15. Development of a graphite probe calorimeter for absolute clinical dosimetry

    International Nuclear Information System (INIS)

    Renaud, James; Seuntjens, Jan; Sarfehnia, Arman; Marchington, David

    2013-01-01

    The aim of this work is to present the numerical design optimization, construction, and experimental proof of concept of a graphite probe calorimeter (GPC) conceived for dose measurement in the clinical environment (U.S. provisional patent 61/652,540). A finite element method (FEM) based numerical heat transfer study was conducted using a commercial software package to explore the feasibility of the GPC and to optimize the shape, dimensions, and materials used in its design. A functioning prototype was constructed inhouse and used to perform dose to water measurements under a 6 MV photon beam at 400 and 1000 MU/min, in a thermally insulated water phantom. Heat loss correction factors were determined using FEM analysis while the radiation field perturbation and the graphite to water absorbed dose conversion factors were calculated using Monte Carlo simulations. The difference in the average measured dose to water for the 400 and 1000 MU/min runs using the TG-51 protocol and the GPC was 0.2% and 1.2%, respectively. Heat loss correction factors ranged from 1.001 to 1.002, while the product of the perturbation and dose conversion factors was calculated to be 1.130. The combined relative uncertainty was estimated to be 1.4%, with the largest contributors being the specific heat capacity of the graphite (type B, 0.8%) and the reproducibility, defined as the standard deviation of the mean measured dose (type A, 0.6%). By establishing the feasibility of using the GPC as a practical clinical absolute photon dosimeter, this work lays the foundation for further device enhancements, including the development of an isothermal mode of operation and an overall miniaturization, making it potentially suitable for use in small and composite radiation fields. It is anticipated that, through the incorporation of isothermal stabilization provided by temperature controllers, a subpercent overall uncertainty will be achieved.

  16. Determination of Absorbed Dose to Water for Leksell Gamma Knife Unit

    International Nuclear Information System (INIS)

    Hrsak, H.

    2013-01-01

    Because of geometry of photon beams in Leksell Gamma Knife Unit (LGK), there are several technical problems in applying standard protocols for determination of absorbed dose to water (Dw). Currently, Dw in LGK unit, measured at the center of spherical plastic phantom, is used for dose calculation in LGK radiosurgery. Treatment planning software (LGP TPS) accepts this value as a measurement in water and since plastic phantom has higher electron density than water, this leads to systematic errors in dose calculation. To reduce these errors, a photon attenuation correction (PAC) method was applied. For that purpose, measurements of absorbed dose in a center of three different plastic phantoms with 16 cm diameter (ABS - acrylonitrile butadiene styrene, PMMA - polymethyl metacrylate, PMMA + teflon - polytetrafluoroethylene 5 mm shell) were made with ionization chamber (Semiflex, PTW Freiburg). For measured dose values, PAC to water was applied based on electron density (ED) and equivalent water depths (EWD) of the plastic phantoms. The relation between CT number and ED was determined by measuring CT number of standard CT to ED phantom (CIRS Model 062 Phantom). Absorbed dose in plastic phantoms was 2.5 % lower than calculated dose in water for ABS phantom and more than 5.5 % lower for PMMA and PMMA+teflon phantom. Calculated dose in water showed more consistent values for all three phantoms (max. difference 2.6 %). EWD for human cranial bones and brain has value close to the EWD of ABS phantom, which makes this phantom most suitable for dose measurements in clinical application. In LGK radiosurgery determination of errors related to the difference of phantom materials should not be neglected and measured dose should be corrected before usage for patient treatment dose calculation.(author)

  17. Alternatives to dose, quality factor and dose equivalent for low level irradiation

    International Nuclear Information System (INIS)

    Sondhaus, C.A.; Bond, V.P.; Feinendegen, L.E.

    1988-01-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to the sensitive target volumes within a small fraction of the cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Normalizing to equal numbers of events produced by different radiations and applying this cell response or hit size effectiveness function (HSEF) should define radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose evaluation, which are confounded when applied to low level irradiations. Examples using both calculation and experimental data are presented. 15 refs., 18 figs

  18. International comparison of calibration standards for exposure and absorbed dose

    International Nuclear Information System (INIS)

    Horakova, I.; Wagner, R.

    1990-01-01

    A comparison was performed of the primary calibration standards for 60 Co gamma radiation dose from Czechoslovakia (UDZ CSAV, Prague), Austria (OEFZS/BEV Seibersdorf) and Hungary (OMH Budapest) using ND 1005 (absolute measurement) and V-415 (by means of N x ) graphite ionization chambers. BEV achieved agreement better than 0.1%, OMH 0.35%. Good agreement was also achieved for the values of exposure obtained in absolute values and those obtained via N x , this for the ND 1005/8105 chamber. The first ever international comparison involving Czechoslovakia was also performed of the unit of absorbed gamma radiation in a water and/or graphite phantom. The participants included Czechoslovakia (UDZ CSAV Prague), the USSR (VNIIFTRI Moscow) and Austria (OEFZS/BEV Seibersdorf). In all measurements, the agreement was better than 1%, which, in view of the differences in methodologies (VNIIFTRI, BEV: calorimetry, UDZ, UVVVR: ionometry) and the overall inaccuracies in determining the absorbed dose values, is a good result. (author)

  19. Neuromuscular dose-response studies: determining sample size.

    Science.gov (United States)

    Kopman, A F; Lien, C A; Naguib, M

    2011-02-01

    Investigators planning dose-response studies of neuromuscular blockers have rarely used a priori power analysis to determine the minimal sample size their protocols require. Institutional Review Boards and peer-reviewed journals now generally ask for this information. This study outlines a proposed method for meeting these requirements. The slopes of the dose-response relationships of eight neuromuscular blocking agents were determined using regression analysis. These values were substituted for γ in the Hill equation. When this is done, the coefficient of variation (COV) around the mean value of the ED₅₀ for each drug is easily calculated. Using these values, we performed an a priori one-sample two-tailed t-test of the means to determine the required sample size when the allowable error in the ED₅₀ was varied from ±10-20%. The COV averaged 22% (range 15-27%). We used a COV value of 25% in determining the sample size. If the allowable error in finding the mean ED₅₀ is ±15%, a sample size of 24 is needed to achieve a power of 80%. Increasing 'accuracy' beyond this point requires increasing greater sample sizes (e.g. an 'n' of 37 for a ±12% error). On the basis of the results of this retrospective analysis, a total sample size of not less than 24 subjects should be adequate for determining a neuromuscular blocking drug's clinical potency with a reasonable degree of assurance.

  20. Absorbed dose to water determination with ionization chamber dosimetry and calorimetry in restricted neutron, photon, proton and heavy-ion radiation fields.

    Science.gov (United States)

    Brede, H J; Greif, K-D; Hecker, O; Heeg, P; Heese, J; Jones, D T L; Kluge, H; Schardt, D

    2006-08-07

    Absolute dose measurements with a transportable water calorimeter and ionization chambers were performed at a water depth of 20 mm in four different types of radiation fields, for a collimated (60)Co photon beam, for a collimated neutron beam with a fluence-averaged mean energy of 5.25 MeV, for collimated proton beams with mean energies of 36 MeV and 182 MeV at the measuring position, and for a (12)C ion beam in a scanned mode with an energy per atomic mass of 430 MeV u(-1). The ionization chambers actually used were calibrated in units of air kerma in the photon reference field of the PTB and in units of absorbed dose to water for a Farmer-type chamber at GSI. The absorbed dose to water inferred from calorimetry was compared with the dose derived from ionometry by applying the radiation-field-dependent parameters. For neutrons, the quantities of the ICRU Report 45, for protons the quantities of the ICRU Report 59 and for the (12)C ion beam, the recommended values of the International Atomic Energy Agency (IAEA) protocol (TRS 398) were applied. The mean values of the absolute absorbed dose to water obtained with these two independent methods agreed within the standard uncertainty (k = 1) of 1.8% for calorimetry and of 3.0% for ionometry for all types and energies of the radiation beams used in this comparison.

  1. Dose determination in computed tomography; Determinacion de dosis en tomografia computada

    Energy Technology Data Exchange (ETDEWEB)

    Descamps, C.; Garrigo, E.; Venencia, D. [Fundacion Marie Curie, Instituto Privado de Radioterapia, Departamento de Fisica Medica, Obispo Oro 423, X5000BFI Cordoba (Argentina); Gonzalez, M. [Universidad Nacional de Cordoba, Facultad de Ciencias Exactas, Fisicas y Naturales, Av. Velez Sarsfield 299, Corboba (Argentina); Germanier, A., E-mail: agermani@ceprocor.uncor.edu [Ministerio de Ciencia y Tecnologia, Ceprocor, Alvarez de Arenas 230, X5004AAP Barrio Juniors, Cordoba (Argentina)

    2011-10-15

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  2. Improvements in absolute seismometer sensitivity calibration using local earth gravity measurements

    Science.gov (United States)

    Anthony, Robert E.; Ringler, Adam; Wilson, David

    2018-01-01

    The ability to determine both absolute and relative seismic amplitudes is fundamentally limited by the accuracy and precision with which scientists are able to calibrate seismometer sensitivities and characterize their response. Currently, across the Global Seismic Network (GSN), errors in midband sensitivity exceed 3% at the 95% confidence interval and are the least‐constrained response parameter in seismic recording systems. We explore a new methodology utilizing precise absolute Earth gravity measurements to determine the midband sensitivity of seismic instruments. We first determine the absolute sensitivity of Kinemetrics EpiSensor accelerometers to 0.06% at the 99% confidence interval by inverting them in a known gravity field at the Albuquerque Seismological Laboratory (ASL). After the accelerometer is calibrated, we install it in its normal configuration next to broadband seismometers and subject the sensors to identical ground motions to perform relative calibrations of the broadband sensors. Using this technique, we are able to determine the absolute midband sensitivity of the vertical components of Nanometrics Trillium Compact seismometers to within 0.11% and Streckeisen STS‐2 seismometers to within 0.14% at the 99% confidence interval. The technique enables absolute calibrations from first principles that are traceable to National Institute of Standards and Technology (NIST) measurements while providing nearly an order of magnitude more precision than step‐table calibrations.

  3. Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

    International Nuclear Information System (INIS)

    Calcina, Carmen S Guzman; Almeida, Adelaide de; Rocha, Jose R Oliveira; Abrego, Felipe Chen; Baffa, Oswaldo

    2005-01-01

    Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40)

  4. Absolute advantage

    NARCIS (Netherlands)

    J.G.M. van Marrewijk (Charles)

    2008-01-01

    textabstractA country is said to have an absolute advantage over another country in the production of a good or service if it can produce that good or service using fewer real resources. Equivalently, using the same inputs, the country can produce more output. The concept of absolute advantage can

  5. Absolute calibration technique for spontaneous fission sources

    International Nuclear Information System (INIS)

    Zucker, M.S.; Karpf, E.

    1984-01-01

    An absolute calibration technique for a spontaneously fissioning nuclide (which involves no arbitrary parameters) allows unique determination of the detector efficiency for that nuclide, hence of the fission source strength

  6. Total Synthesis and Absolute Configuration of the Marine Norditerpenoid Xestenone

    Directory of Open Access Journals (Sweden)

    Hiroaki Miyaoka

    2009-11-01

    Full Text Available Xestenone is a marine norditerpenoid found in the northeastern Pacific sponge Xestospongia vanilla. The relative configuration of C-3 and C-7 in xestenone was determined by NOESY spectral analysis. However the relative configuration of C-12 and the absolute configuration of this compound were not determined. The authors have now achieved the total synthesis of xestenone using their developed one-pot synthesis of cyclopentane derivatives employing allyl phenyl sulfone and an epoxy iodide as a key step. The relative and absolute configurations of xestenone were thus successfully determined by this synthesis.

  7. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  8. Dose determination on buildup region using photodiodes

    International Nuclear Information System (INIS)

    Khoury, H.J.; Lopes, F.J.; Melo, F. de A.

    1989-01-01

    A clinical dosemeter using photodiode BPW-34 was developed, allowing the determination of dose on buildup region. The measures were made with X-rays beam of linear accelerator and with gamma radiation of cobalt 60. The results were compared with others made in a ionization chamber. (C.G.C.) [pt

  9. Determining effective radiation mutagen dose for garlic (Allium sativum L.)

    International Nuclear Information System (INIS)

    Taner, Y.; Kunter, B.

    2004-01-01

    This study was carried out to get database for future garlic mutation breeding studies. For this aim, 0, 5, 10, 15, 20, 25 and 30 Gy doses of Cs 137 (gamma-ray) were applied on garlic cloves as a physical mutagen. 50 cloves were used for each dose. Sixty days after treatment, germination rate and shoot development of cloves were determined. The Effective Mutagen Dose (ED 50 ) was calculated by regression analyses. According to the results, 4.455 Gy dose was found to be effective as ED 50 . (author)

  10. Committed effective dose determination in southern Brazilian cereal flours.

    Science.gov (United States)

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  11. Committed effective dose determination in southern Brazilian cereal flours

    International Nuclear Information System (INIS)

    Scheibel, V.; Appoloni, C. R.

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of 228 Th, 228 Ra, 226 Ra, 40 K, 7 Be and 137 Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of 228 Th and 40 K were 3.5±0.4 and 1469±17 Bq kg -1 for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for 137 Cs ranged from 0.04 to 0.4 Bq kg -1 . The highest committed effective dose was 0.36 μSv.y -1 for 228 Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y -1 , to the public exposure. (authors)

  12. Efficacy of intrahepatic absolute alcohol in unrespectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Hameed, K.; Khan, I.U.; Shah, S.

    2001-01-01

    To determine efficacy of intrahepatic absolute alcohol injection in researchable hepatocellular carcinoma. A randomized, controlled, experimental and interventional clinical trial. Gastroenterology Department, PGMI, Hayatabad Medical Complex, Peshawar during the period from June, 1998 to June, 2000. Thirty patients were treated by percutaneous, intrahepatic absolute alcohol injection sin repeated sessions, 33 patients were not given or treated with alcohol to serve as control. Both the groups were comparable for age, sex and other baseline characteristics. Absolute alcohol therapy significantly improved quality of life of patients, reduced the tumor size and mortality as well as showed significantly better results regarding survival (P< 0.05) than the patients of control group. We conclude that absolute alcohol is a beneficial and safe palliative treatment measure in advanced hepatocellular carcinoma (HCC). (author)

  13. Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-07-15

    Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement

  14. Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin.

    Science.gov (United States)

    Shibata, Kaito; Naito, Takafumi; Okamura, Jun; Hosokawa, Seiji; Mineta, Hiroyuki; Kawakami, Junichi

    2017-11-30

    Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200μg/mL. The lower limit of quantification of cetuximab in human serum was 4μg/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140μg/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r=0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Indoor external dose rates due to decorative sheet stone

    Energy Technology Data Exchange (ETDEWEB)

    Lu, C.H.; Sheu, R.D.; Jiang, S.H. [Dept. of Engineering and System Science, National Tsing Hua Univ., Hsinchu (Taiwan)

    2002-03-01

    The specific activities in decorative sheet stone made of granite or marble were measured, whereby the absolute peak efficiency of the HPGe detectors employed in the measurements for the sheet-stone sample was determined using the semi-empirical method. The spatial distribution for the indoor external dose rates due to the radionuclides present in the decorative sheet stone used to clad the floor and the four walls of a standard room was calculated using a three-dimensional point kernel computer code. It was found that the spatial distribution for the indoor dose rates was complex and non-uniform, which represents a difference in relation to the results of earlier studies. (orig.)

  16. Indoor external dose rates due to decorative sheet stone

    International Nuclear Information System (INIS)

    Lu, C.H.; Sheu, R.D.; Jiang, S.H.

    2002-01-01

    The specific activities in decorative sheet stone made of granite or marble were measured, whereby the absolute peak efficiency of the HPGe detectors employed in the measurements for the sheet-stone sample was determined using the semi-empirical method. The spatial distribution for the indoor external dose rates due to the radionuclides present in the decorative sheet stone used to clad the floor and the four walls of a standard room was calculated using a three-dimensional point kernel computer code. It was found that the spatial distribution for the indoor dose rates was complex and non-uniform, which represents a difference in relation to the results of earlier studies. (orig.)

  17. Determination of the absolute configurations at stereogenic centers in the presence of axial chirality.

    Science.gov (United States)

    Polavarapu, Prasad L; Jeirath, Neha; Kurtán, Tibor; Pescitelli, Gennaro; Krohn, Karsten

    2009-01-01

    Cephalochromin, a homodimeric naphthpyranone natural product, contains both axial chirality due to the hindered rotation along the biaryl axis and central chirality due to the C-2, C-2' stereogenic centers of the fused pyranone ring. For determining the absolute configurations (ACs) of central chirality elements, different chiroptical spectroscopic methods, namely vibrational circular dichroism (VCD), electronic circular dichroism (ECD), and optical rotation (OR), have been used. From these experimental data, in conjunction with corresponding quantum chemical predictions at B3LYP/6-311G* level, it is found that the ECD spectra of cephalochromin are dominated by its axial chirality and are not suitable to distinguish the (aS,2S,2'S) and (aS,2R,2'R) diastereomers and hence to determine the ACs of the central chirality elements. OR signs also did not distinguish the (aS,2S,2'S) and (aS,2R,2'R) diastereomers. On other hand, VCD spectrum of cephalochromin exhibited separate spectral features attributable to axial chirality and stereogenic centers, thereby allowing the determination of both types of chirality elements. This is the first investigation demonstrating that, because of vibrations specific to the studied stereogenic centers, VCD spectroscopy can be used to simultaneously determine the ACs of axial and central chirality elements whenever other chiroptical methods (ECD and OR) fail to report on them. (c) 2009 Wiley-Liss, Inc.

  18. Selective segmental sclerotherapy of the liver by transportal absolute ethanol injection: an animal experimental study

    International Nuclear Information System (INIS)

    Pan Jie; Yang Ning; Zhang Zhongzhong; Hu Libin; Chen Jie; Wu Wei; Jin Zhengyu; Liu Wei

    2003-01-01

    Objective: To evaluate the safety and efficacy of selective segmental sclerotherapy (SSS) of the liver by transportal absolute ethanol injection with an animal experimental study, and to discuss several technical points involved in this method. Methods: Thirty dogs received SSS of the liver by transportal absolute ethanol injection with the injection dose of 0.2-1.0 ml/kg, repeated examinations of blood ethanol level, WBC, and liver functions were done, and CT and pathological examinations of the liver were performed. Results: All dogs treated with SSS survived during the study. The maximum elevation of blood ethanol values occurred in group F. Its average value was (1.603 ± 0.083) mg/ml, which was much lower than that of death level. Transient elevations of blood WBC and ALT were seen. The average values of WBC and ALT were (46.36 ± 7.28) x 10 9 and (827.36 ± 147.25) U/L, respectively. CT and pathological examinations proved that the dogs given SSS by transportal absolute ethanol injection with the injection dose of 0.3-1.0 ml/kg had a complete wedge-shaped necrosis in the liver. Conclusion: Selective segmental sclerotherapy of the liver by transportal ethanol injection was quite safe and effective if the proper dose of ethanol was injected. SSS may be useful in the treatment of HCC

  19. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    International Nuclear Information System (INIS)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn; Wei, Lihui

    2015-01-01

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision

  20. Reduced dose measurement of absolute myocardial blood flow using dynamic SPECT imaging in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Timmins, Rachel; Klein, Ran; Petryk, Julia; Marvin, Brian; Kemp, Robert A. de; Ruddy, Terrence D.; Wells, R. Glenn, E-mail: gwells@ottawaheart.ca [Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada); Wei, Lihui [Nordion, Inc., Ottawa, Ontario K2K 1X8 (Canada)

    2015-09-15

    Purpose: Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements provide important additional information over traditional relative perfusion imaging. Recent advances in camera technology have made this possible with single-photon emission tomography (SPECT). Low dose protocols are desirable to reduce the patient radiation risk; however, increased noise may reduce the accuracy of MBF measurements. The authors studied the effect of reducing dose on the accuracy of dynamic SPECT MBF measurements. Methods: Nineteen 30–40 kg pigs were injected with 370 + 1110 MBq of Tc-99m sestamibi or tetrofosmin or 37 + 111 MBq of Tl-201 at rest + stress. Microspheres were injected simultaneously to measure MBF. The pigs were imaged in list-mode for 11 min starting at the time of injection using a Discovery NM 530c camera (GE Healthcare). Each list file was modified so that 3/4, 1/2, 1/4, 1/8, 1/16, and 1/32 of the original counts were included in the projections. Modified projections were reconstructed with CT-based attenuation correction and an energy window-based scatter correction and analyzed with FlowQuant kinetic modeling software using a 1-compartment model. A modified Renkin-Crone extraction function was used to convert the tracer uptake rate K1 to MBF values. The SPECT results were compared to those from microspheres. Results: Correlation between SPECT and microsphere MBF values for the full injected activity was r ≥ 0.75 for all 3 tracers and did not significantly degrade over all count levels. The mean MBF and MFR and the standard errors in the estimates were not significantly worse than the full-count data at 1/4-counts (Tc99m-tracers) and 1/2-counts (Tl-201). Conclusions: Dynamic SPECT measurement of MBF and MFR in pigs can be performed with 1/4 (Tc99m-tracers) or 1/2 (Tl-201) of the standard injected activity without significantly reducing accuracy and precision.

  1. Absolutely relative or relatively absolute: violations of value invariance in human decision making.

    Science.gov (United States)

    Teodorescu, Andrei R; Moran, Rani; Usher, Marius

    2016-02-01

    Making decisions based on relative rather than absolute information processing is tied to choice optimality via the accumulation of evidence differences and to canonical neural processing via accumulation of evidence ratios. These theoretical frameworks predict invariance of decision latencies to absolute intensities that maintain differences and ratios, respectively. While information about the absolute values of the choice alternatives is not necessary for choosing the best alternative, it may nevertheless hold valuable information about the context of the decision. To test the sensitivity of human decision making to absolute values, we manipulated the intensities of brightness stimuli pairs while preserving either their differences or their ratios. Although asked to choose the brighter alternative relative to the other, participants responded faster to higher absolute values. Thus, our results provide empirical evidence for human sensitivity to task irrelevant absolute values indicating a hard-wired mechanism that precedes executive control. Computational investigations of several modelling architectures reveal two alternative accounts for this phenomenon, which combine absolute and relative processing. One account involves accumulation of differences with activation dependent processing noise and the other emerges from accumulation of absolute values subject to the temporal dynamics of lateral inhibition. The potential adaptive role of such choice mechanisms is discussed.

  2. Determination of the equivalent of environmental dose, H*(d), in a radiotherapy installation

    International Nuclear Information System (INIS)

    Lima, M.A.F.; Borges, J.C.; Mota, H.C.

    1998-01-01

    In order to put into practice radiological protection has been required conversion factors for environmental dose equivalent determination to air kerma value for different kinds of photon and electron beams, such dose values have been determined in a spheric phantom of 30 cm diameter in a alignment field and expanded in a depth of this sphere. Details will be given for determining of equivalent dose distribution calculation using Monte Carlo computational method (ESG4) following the recommendations of ICRU. (Author)

  3. Determination of eye lenses dose equivalent in terms of Hp(3)

    International Nuclear Information System (INIS)

    Klamert, V.; Caresana, M.; Minchillo, G.; Tambussi, O.

    2002-01-01

    The Italian radioprotection legislation requires the determination of personal dose equivalent in terms of H p (10) and H p (0.07) and the determination of the eye lenses dose equivalent in terms of H p (3). Whereas the calibration of a dosemeter for the determination of H p (10) and H p (0.07) is feasible, the calibration of a dosemeter in terms of H p (3) is impossible, owing to the absence of the suitable phantom and the conversion coefficients h pk (3) from air kerma to H p (3). Using an anthropomorphic phantom for the irradiation, the aim of this work is to determine the experimental values of the conversion coefficients and to relate the result of the dosemeter worn on the forehead with the dose equivalent to the eye lenses. The study is performed in the X energy range from 30 keV to 100 keV, i.e. the one most widely used in medical practices

  4. Determining the absolute abundance of dinoflagellate cysts in recent marine sediments: The Lycopodium marker-grain method put to the test

    DEFF Research Database (Denmark)

    Mertens, K; Verhoeven; Verleye

    2009-01-01

    Absolute abundances (concentrations) of dinoflagellate cysts are often determined through the addition of Lycopodium clavatum marker-grains as a spike to a sample before palynological processing. An inter-laboratory calibration exercise was set up in order to test the comparability of results obt...

  5. Faraday cup: absolute dosimetry for ELIMED beam line

    International Nuclear Information System (INIS)

    Leanza, R.; Romano, F.; Scuderi, V.; Amico, A.G.; Cuttone, G.; Larosa, G.; Milluzzo, G.; Petringa, G.; Pipek, J.; Cirrone, G.A.P.; Margarone, D.; Schillaci, F.

    2017-01-01

    The scientific community has shown a growing interest towards multidisciplinary applications of laser-driven beams. In this framework, the ELIMED (ELI-Beamlines MEDical and multidisciplinary applications) beamline will be the first transport beamline dedicated to the medical and multidisciplinary studies with laser-accelerated ion beams. Detectors for dosimetry represent one of key-element of the ELIMED beamline, allowing a dose delivering with good result as required in the clinical applications. In this contribution, a Faraday Cup for absolute dosimetry, designed and realized at INFN-LNS, is described.

  6. Determination of subjective similarity for pairs of masses and pairs of clustered microcalcifications on mammograms: Comparison of similarity ranking scores and absolute similarity ratings

    International Nuclear Information System (INIS)

    Muramatsu, Chisako; Li Qiang; Schmidt, Robert A.; Shiraishi, Junji; Suzuki, Kenji; Newstead, Gillian M.; Doi, Kunio

    2007-01-01

    The presentation of images that are similar to that of an unknown lesion seen on a mammogram may be helpful for radiologists to correctly diagnose that lesion. For similar images to be useful, they must be quite similar from the radiologists' point of view. We have been trying to quantify the radiologists' impression of similarity for pairs of lesions and to establish a ''gold standard'' for development and evaluation of a computerized scheme for selecting such similar images. However, it is considered difficult to reliably and accurately determine similarity ratings, because they are subjective. In this study, we compared the subjective similarities obtained by two different methods, an absolute rating method and a 2-alternative forced-choice (2AFC) method, to demonstrate that reliable similarity ratings can be determined by the responses of a group of radiologists. The absolute similarity ratings were previously obtained for pairs of masses and pairs of microcalcifications from five and nine radiologists, respectively. In this study, similarity ranking scores for eight pairs of masses and eight pairs of microcalcifications were determined by use of the 2AFC method. In the first session, the eight pairs of masses and eight pairs of microcalcifications were grouped and compared separately for determining the similarity ranking scores. In the second session, another similarity ranking score was determined by use of mixed pairs, i.e., by comparison of the similarity of a mass pair with that of a calcification pair. Four pairs of masses and four pairs of microcalcifications were grouped together to create two sets of eight pairs. The average absolute similarity ratings and the average similarity ranking scores showed very good correlations in the first study (Pearson's correlation coefficients: 0.94 and 0.98 for masses and microcalcifications, respectively). Moreover, in the second study, the correlations between the absolute ratings and the ranking scores were also

  7. Relationship between Income and Subjective Economic Well-Being: Absolute or Relative?

    Directory of Open Access Journals (Sweden)

    V A Khashchenko

    2012-09-01

    Full Text Available The article considers the role of the absolute and relative income in determining the subjective economic well-being. It is shown that the relationship of the income to SEB is curvilinear with the increase of marginal utility for a higher income. At low income levels its effect on SEB is determined not by its absolute, but by its relative value based on the comparisons with the subjective standards of well-being.

  8. Calculation and mitigation of isotopic interferences in liquid chromatography-mass spectrometry/mass spectrometry assays and its application in supporting microdose absolute bioavailability studies.

    Science.gov (United States)

    Gu, Huidong; Wang, Jian; Aubry, Anne-Françoise; Jiang, Hao; Zeng, Jianing; Easter, John; Wang, Jun-sheng; Dockens, Randy; Bifano, Marc; Burrell, Richard; Arnold, Mark E

    2012-06-05

    A methodology for the accurate calculation and mitigation of isotopic interferences in liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays and its application in supporting microdose absolute bioavailability studies are reported for the first time. For simplicity, this calculation methodology and the strategy to minimize the isotopic interference are demonstrated using a simple molecule entity, then applied to actual development drugs. The exact isotopic interferences calculated with this methodology were often much less than the traditionally used, overestimated isotopic interferences simply based on the molecular isotope abundance. One application of the methodology is the selection of a stable isotopically labeled internal standard (SIL-IS) for an LC-MS/MS bioanalytical assay. The second application is the selection of an SIL analogue for use in intravenous (i.v.) microdosing for the determination of absolute bioavailability. In the case of microdosing, the traditional approach of calculating isotopic interferences can result in selecting a labeling scheme that overlabels the i.v.-dosed drug or leads to incorrect conclusions on the feasibility of using an SIL drug and analysis by LC-MS/MS. The methodology presented here can guide the synthesis by accurately calculating the isotopic interferences when labeling at different positions, using different selective reaction monitoring (SRM) transitions or adding more labeling positions. This methodology has been successfully applied to the selection of the labeled i.v.-dosed drugs for use in two microdose absolute bioavailability studies, before initiating the chemical synthesis. With this methodology, significant time and cost saving can be achieved in supporting microdose absolute bioavailability studies with stable labeled drugs.

  9. On determining dose rate constants spectroscopically

    International Nuclear Information System (INIS)

    Rodriguez, M.; Rogers, D. W. O.

    2013-01-01

    Purpose: To investigate several aspects of the Chen and Nath spectroscopic method of determining the dose rate constants of 125 I and 103 Pd seeds [Z. Chen and R. Nath, Phys. Med. Biol. 55, 6089–6104 (2010)] including the accuracy of using a line or dual-point source approximation as done in their method, and the accuracy of ignoring the effects of the scattered photons in the spectra. Additionally, the authors investigate the accuracy of the literature's many different spectra for bare, i.e., unencapsulated 125 I and 103 Pd sources. Methods: Spectra generated by 14 125 I and 6 103 Pd seeds were calculated in vacuo at 10 cm from the source in a 2.7 × 2.7 × 0.05 cm 3 voxel using the EGSnrc BrachyDose Monte Carlo code. Calculated spectra used the initial photon spectra recommended by AAPM's TG-43U1 and NCRP (National Council of Radiation Protection and Measurements) Report 58 for the 125 I seeds, or TG-43U1 and NNDC(2000) (National Nuclear Data Center, 2000) for 103 Pd seeds. The emitted spectra were treated as coming from a line or dual-point source in a Monte Carlo simulation to calculate the dose rate constant. The TG-43U1 definition of the dose rate constant was used. These calculations were performed using the full spectrum including scattered photons or using only the main peaks in the spectrum as done experimentally. Statistical uncertainties on the air kerma/history and the dose rate/history were ⩽0.2%. The dose rate constants were also calculated using Monte Carlo simulations of the full seed model. Results: The ratio of the intensity of the 31 keV line relative to that of the main peak in 125 I spectra is, on average, 6.8% higher when calculated with the NCRP Report 58 initial spectrum vs that calculated with TG-43U1 initial spectrum. The 103 Pd spectra exhibit an average 6.2% decrease in the 22.9 keV line relative to the main peak when calculated with the TG-43U1 rather than the NNDC(2000) initial spectrum. The measured values from three different

  10. Absolute orbit determination using line-of-sight vector measurements between formation flying spacecraft

    Science.gov (United States)

    Ou, Yangwei; Zhang, Hongbo; Li, Bin

    2018-04-01

    The purpose of this paper is to show that absolute orbit determination can be achieved based on spacecraft formation. The relative position vectors expressed in the inertial frame are used as measurements. In this scheme, the optical camera is applied to measure the relative line-of-sight (LOS) angles, i.e., the azimuth and elevation. The LIDAR (Light radio Detecting And Ranging) or radar is used to measure the range and we assume that high-accuracy inertial attitude is available. When more deputies are included in the formation, the formation configuration is optimized from the perspective of the Fisher information theory. Considering the limitation on the field of view (FOV) of cameras, the visibility of spacecraft and the installation of cameras are investigated. In simulations, an extended Kalman filter (EKF) is used to estimate the position and velocity. The results show that the navigation accuracy can be enhanced by using more deputies and the installation of cameras significantly affects the navigation performance.

  11. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  12. An Update on the Depth-Dose Curve of Antiprotons

    DEFF Research Database (Denmark)

    Taasti, Vicki Trier; Holzscheiter, Michael H.; Knudsen, Helge

    in water. The experimental results are compared with the Monte Carlo particle transport code SHIELD-HIT12A. Contrary to [1], here the full ionization chamber is simulated and the dose is scored in the ionization chamber air gap. Stopping power ratios are determined as well in order to translate...... the simulated dose to dose-to-water formalism. Results: Generally, the experimental data are in good agreement with the simulated dose on an absolute scale in the plateau region. However some deviations are found near the annihilation peak. A full geometric description of the ionization chamber simulation...... improves the situation, in particular on the upstream side of the Bragg-peak. This is attributed to a different spectrum of annihilation products created in the entrance window of the ionization chamber in comparison to the case of simply simulating annihilation taking place on water. Yet, a large portion...

  13. Absolute magnitudes by statistical parallaxes

    International Nuclear Information System (INIS)

    Heck, A.

    1978-01-01

    The author describes an algorithm for stellar luminosity calibrations (based on the principle of maximum likelihood) which allows the calibration of relations of the type: Msub(i)=sup(N)sub(j=1)Σqsub(j)Csub(ij), i=1,...,n, where n is the size of the sample at hand, Msub(i) are the individual absolute magnitudes, Csub(ij) are observational quantities (j=1,...,N), and qsub(j) are the coefficients to be determined. If one puts N=1 and Csub(iN)=1, one has q 1 =M(mean), the mean absolute magnitude of the sample. As additional output, the algorithm provides one also with the dispersion in magnitude of the sample sigmasub(M), the mean solar motion (U,V,W) and the corresponding velocity ellipsoid (sigmasub(u), sigmasub(v), sigmasub(w). The use of this algorithm is illustrated. (Auth.)

  14. Low-Dose Radiation Cataract and Genetic Determinants of Radiosensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Kleiman, Norman Jay [Columbia University

    2013-11-30

    The lens of the eye is one of the most radiosensitive tissues in the body. Ocular ionizing radiation exposure results in characteristic, dose related, progressive lens changes leading to cataract formation. While initial, early stages of lens opacification may not cause visual disability, the severity of such changes progressively increases with dose until vision is impaired and cataract extraction surgery may be required. Because of the transparency of the eye, radiation induced lens changes can easily be followed non-invasively over time. Thus, the lens provides a unique model system in which to study the effects of low dose ionizing radiation exposure in a complex, highly organized tissue. Despite this observation, considerable uncertainties remain surrounding the relationship between dose and risk of developing radiation cataract. For example, a growing number of human epidemiological findings suggest significant risk among various groups of occupationally and accidentally exposed individuals and confidence intervals that include zero dose. Nevertheless, questions remain concerning the relationship between lens opacities, visual disability, clinical cataract, threshold dose and/or the role of genetics in determining radiosensitivity. Experimentally, the response of the rodent eye to radiation is quite similar to that in humans and thus animal studies are well suited to examine the relationship between radiation exposure, genetic determinants of radiosensitivity and cataractogenesis. The current work has expanded our knowledge of the low-dose effects of X-irradiation or high-LET heavy ion exposure on timing and progression of radiation cataract and has provided new information on the genetic, molecular, biochemical and cell biological features which contribute to this pathology. Furthermore, findings have indicated that single and/or multiple haploinsufficiency for various genes involved in DNA repair and cell cycle checkpoint control, such as Atm, Brca1 or Rad9

  15. Resolution and Determination of the Absolute Configuration of a Twisted Bis-Lactam Analogue of Troger's Base: A Comparative Spectroscopic and Computational Study

    DEFF Research Database (Denmark)

    Rúnarsson, Ögmundur Vidar; Benkhäuser, Christian; Christensen, Niels Johan

    2015-01-01

    ) and electronic circular dichroism (ECD) spectra. The absolute configuration of (-)-2 was determined by comparing experimental and calculated electronic circular dichroism (ECD) spectra. The corresponding theoretical spectra were calculated using the lowest energy conformation of (R,R)-2 and (S,S)-2 at the B3LYP...

  16. Absolute gravity measurements in California

    Science.gov (United States)

    Zumberge, M. A.; Sasagawa, G.; Kappus, M.

    1986-08-01

    An absolute gravity meter that determines the local gravitational acceleration by timing a freely falling mass with a laser interferometer has been constructed. The instrument has made measurements at 11 sites in California, four in Nevada, and one in France. The uncertainty in the results is typically 10 microgal. Repeated measurements have been made at several of the sites; only one shows a substantial change in gravity.

  17. Genomic DNA-based absolute quantification of gene expression in Vitis.

    Science.gov (United States)

    Gambetta, Gregory A; McElrone, Andrew J; Matthews, Mark A

    2013-07-01

    Many studies in which gene expression is quantified by polymerase chain reaction represent the expression of a gene of interest (GOI) relative to that of a reference gene (RG). Relative expression is founded on the assumptions that RG expression is stable across samples, treatments, organs, etc., and that reaction efficiencies of the GOI and RG are equal; assumptions which are often faulty. The true variability in RG expression and actual reaction efficiencies are seldom determined experimentally. Here we present a rapid and robust method for absolute quantification of expression in Vitis where varying concentrations of genomic DNA were used to construct GOI standard curves. This methodology was utilized to absolutely quantify and determine the variability of the previously validated RG ubiquitin (VvUbi) across three test studies in three different tissues (roots, leaves and berries). In addition, in each study a GOI was absolutely quantified. Data sets resulting from relative and absolute methods of quantification were compared and the differences were striking. VvUbi expression was significantly different in magnitude between test studies and variable among individual samples. Absolute quantification consistently reduced the coefficients of variation of the GOIs by more than half, often resulting in differences in statistical significance and in some cases even changing the fundamental nature of the result. Utilizing genomic DNA-based absolute quantification is fast and efficient. Through eliminating error introduced by assuming RG stability and equal reaction efficiencies between the RG and GOI this methodology produces less variation, increased accuracy and greater statistical power. © 2012 Scandinavian Plant Physiology Society.

  18. Determination of the absolute efficiency of an organic scintillator for neutrons with energies between 0.5 and 800 MeV

    International Nuclear Information System (INIS)

    Howe, S.D.; Lisowski, P.W.; Russell, G.J.; King, N.S.P.; Donnert, H.J.

    1984-01-01

    We have determined the absolute efficiency of an NE-213 scintillator for neutrons with energies from 0.5 to 800 MeV. The detector was 5.1 cm in diameter and 2.5 cm deep. The efficiencies were obtained for detector thresholds of 0.011, 0.48, 1.12, and 4.48 MeVee. Our results are compared to predictions of the STANTON computer code. (orig.)

  19. SU-G-BRB-15: Verifications of Absolute and Relative Dosimetry of a Novel Stereotactic Breast Device: GammaPodTM

    Energy Technology Data Exchange (ETDEWEB)

    Becker, S; Mossahebi, S; Yi, B; Prado, K; Mutaf, Y [University of Maryland School Of Medicine (United States); Niu, Y [Xcision Medical Systems, Rockville, MD (United States); Yu, C [University of Maryland School Of Medicine (United States); Xcision Medical Systems, Rockville, MD (United States)

    2016-06-15

    Purpose: A dedicated stereotactic breast radiotherapy device, GammaPod, was developed to treat early stage breast cancer. The first clinical unit was installed and commissioned at University of Maryland. We report our methodology of absolute dosimetry in multiple calibration conditions and dosimetric verifications of treatment plans produced by the system. Methods: GammaPod unit is comprised of a rotating hemi-spherical source carrier containing 36 Co-60 sources and a concentric tungsten collimator providing beams of 15 and 25 mm. Absolute dose calibration formalism was developed with modifications to AAPM protocols for unique geometry and different calibration medium (acrylic, polyethylene or liquid water). Breast cup-size specific and collimator output factors were measured and verified with respect to Monte-Carlo simulations for single isocenter plans. Multiple isocenter plans were generated for various target size, location and cup-sizes in phantoms and 20 breast cancer patients images. Stereotactic mini-farmer chamber, OSL and TLD detectors as well as radio-chromic films were used for dosimetric measurements. Results: At the time of calibration (1/14/2016), absolute dose rate of the GammaPod was established to be 2.10 Gy/min in acrylic for 25 mm for sources installed in March 2011. Output factor for 15 mm collimator was measured to be 0.950. Absolute dose calibration was independently verified by IROC-Houston with a TLD/Institution ratio of 0.99. Cup size specific output measurements in liquid water for single isocenter were found to be within 3.0% of MC simulations. Point-dose measurements of multiple isocenter treatment plans were found to be within −1.0 ± 1.2 % of treatment planning system while 2-dimensional gamma analysis yielded a pass rate of 97.9 ± 2.2 % using gamma criteria of 3% and 2mm. Conclusion: The first GammaPod treatment unit for breast stereotactic radiotherapy was successfully installed, calibrated and commissioned for patient treatments

  20. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  1. Absolute cross sections from the ''boomerang model'' for resonant electron-molecule scattering

    International Nuclear Information System (INIS)

    Dube, L.; Herzenberg, A.

    1979-01-01

    The boomerang model is used to calculate absolute cross sections near the 2 Pi/sub g/ shape resonance in e-N 2 scattering. The calculated cross sections are shown to satisfy detailed balancing. The exchange of electrons is taken into account. A parametrized complex-potential curve for the intermediate N 2 /sup ts-/ ion is determined from a small part of the experimental data, and then used to calculate other properties. The calculations are in good agreement with the absolute cross sections for vibrational excitation from the ground state, the absolute cross section v = 1 → 2, and the absolute total cross section

  2. The bolometric, infrared and visual absolute magnitudes of Mira variables

    International Nuclear Information System (INIS)

    Robertson, B.S.C.; Feast, M.W.

    1981-01-01

    Statistical parallaxes, as well as stars with individually known distances are used to derive bolometric and infrared absolute magnitudes of Mira (Me) variables. The derived bolometric magnitudes are in the mean about 0.75 mag fainter than recent estimates. The problem of determining the pulsation constant is discussed. Miras with periods greater than 150 days probably pulsate in the first overtone. Those of shorter periods are anomalous and may be fundamental pulsators. It is shown that the absolute visual magnitudes at mean light of Miras with individually determined distances are consistent with values derived by Clayton and Feast from statistical parallaxes. (author)

  3. A simple method to back-project isocenter dose of radiotherapy treatments using EPID transit dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, T.B.; Cerbaro, B.Q.; Rosa, L.A.R. da, E-mail: thiago.fisimed@gmail.com, E-mail: tbsilveira@inca.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro - RJ (Brazil)

    2017-07-01

    The aim of this work was to implement a simple algorithm to evaluate isocenter dose in a phantom using the back-projected transmitted dose acquired using an Electronic Portal Imaging Device (EPID) available in a Varian Trilogy accelerator with two nominal 6 and 10 MV photon beams. This algorithm was developed in MATLAB language, to calibrate EPID measured dose in absolute dose, using a deconvolution process, and to incorporate all scattering and attenuation contributions due to photon interactions with phantom. Modeling process was simplified by using empirical curve adjustments to describe the contribution of scattering and attenuation effects. The implemented algorithm and method were validated employing 19 patient treatment plans with 104 clinical irradiation fields projected on the phantom used. Results for EPID absolute dose calibration by deconvolution have showed percent deviations lower than 1%. Final method validation presented average percent deviations between isocenter doses calculated by back-projection and isocenter doses determined with ionization chamber of 1,86% (SD of 1,00%) and -0,94% (SD of 0,61%) for 6 and 10 MV, respectively. Normalized field by field analysis showed deviations smaller than 2% for 89% of all data for 6 MV beams and 94% for 10 MV beams. It was concluded that the proposed algorithm possesses sufficient accuracy to be used for in vivo dosimetry, being sensitive to detect dose delivery errors bigger than 3-4% for conformal and intensity modulated radiation therapy techniques. (author)

  4. Stable isotope-labelled intravenous microdose for absolute bioavailability and effect of grapefruit juice on ibrutinib in healthy adults.

    Science.gov (United States)

    de Vries, Ronald; Smit, Johan W; Hellemans, Peter; Jiao, James; Murphy, Joseph; Skee, Donna; Snoeys, Jan; Sukbuntherng, Juthamas; Vliegen, Maarten; de Zwart, Loeckie; Mannaert, Erik; de Jong, Jan

    2016-02-01

    Ibrutinib, an inhibitor of Bruton's tyrosine kinase, is used in the treatment of mantle cell lymphoma or chronic lymphocytic leukaemia. Ibrutinib undergoes extensive rapid oxidative metabolism mediated by cytochrome P450 3A both at the level of first pass and clearance, which might result in low oral bioavailability. The present study was designed to investigate the absolute bioavailability (F) of ibrutinib in the fasting and fed state and assess the effect of grapefruit juice (GFJ) on the systemic exposure of ibrutinib in order to determine the fraction escaping the gut (Fg ) and the fraction escaping hepatic extraction (Fh ) in the fed state. All participants received treatment A [560 mg oral ibrutinib, under fasting conditions], B (560 mg PO ibrutinib, fed, administered after drinking glucose drink) and C (140 mg oral ibrutinib, fed, with intake of GFJ before dosing). A single intravenous (i.v.) dose of 100 μg (13) C6 -ibrutinib was administered 2 h after each oral dose. The estimated 'F' for treatments A, B and C was 3.9%, 8.4% and 15.9%, respectively. Fg and Fh in the fed state were 47.0% and 15.9%, respectively. Adverse events were mild to moderate in severity (Grade 1-2) and resolved without sequelae by the end of the study. The absolute oral bioavailability of ibrutinib was low, ranging from 3.9% in the fasting state to 8.4% when administered 30 min before a standard breakfast without GFJ and 15.9% with GFJ. Ibrutinib was well tolerated following a single oral and i.v. dose, under both fasted and fed conditions and regardless of GFJ intake status. © 2015 The British Pharmacological Society.

  5. Stable isotope‐labelled intravenous microdose for absolute bioavailability and effect of grapefruit juice on ibrutinib in healthy adults

    Science.gov (United States)

    Smit, Johan W.; Hellemans, Peter; Jiao, James; Murphy, Joseph; Skee, Donna; Snoeys, Jan; Sukbuntherng, Juthamas; Vliegen, Maarten; de Zwart, Loeckie; Mannaert, Erik; de Jong, Jan

    2016-01-01

    Aims Ibrutinib, an inhibitor of Bruton's tyrosine kinase, is used in the treatment of mantle cell lymphoma or chronic lymphocytic leukaemia. Ibrutinib undergoes extensive rapid oxidative metabolism mediated by cytochrome P450 3A both at the level of first pass and clearance, which might result in low oral bioavailability. The present study was designed to investigate the absolute bioavailability (F) of ibrutinib in the fasting and fed state and assess the effect of grapefruit juice (GFJ) on the systemic exposure of ibrutinib in order to determine the fraction escaping the gut (Fg) and the fraction escaping hepatic extraction (Fh) in the fed state. Methods All participants received treatment A [560 mg oral ibrutinib, under fasting conditions], B (560 mg PO ibrutinib, fed, administered after drinking glucose drink) and C (140 mg oral ibrutinib, fed, with intake of GFJ before dosing). A single intravenous (i.v.) dose of 100 μg 13C6‐ibrutinib was administered 2 h after each oral dose. Results The estimated ‘F’ for treatments A, B and C was 3.9%, 8.4% and 15.9%, respectively. Fg and Fh in the fed state were 47.0% and 15.9%, respectively. Adverse events were mild to moderate in severity (Grade 1–2) and resolved without sequelae by the end of the study. Conclusion The absolute oral bioavailability of ibrutinib was low, ranging from 3.9% in the fasting state to 8.4% when administered 30 min before a standard breakfast without GFJ and 15.9% with GFJ. Ibrutinib was well tolerated following a single oral and i.v. dose, under both fasted and fed conditions and regardless of GFJ intake status. PMID:26382728

  6. Determination of crossed gamma doses for garlic improvement (Allium Sativum)

    International Nuclear Information System (INIS)

    Perez Talavera, S.; Labrada, A.; Savin, V.

    1991-01-01

    The determination of four Cuban varieties of garlic was made so as to optimized the use of ionizing radiations in Cuba to breed vegetatively propagated crops such as garlic. The dose-effect regresion equation characterizing the radioinhibition zone of each crop was presented. We used a criteria to select the irradiation dose to be used in mutation breeding techniques based on obtaining height variability in the productive indicators, a survival and a number of garlic cloves high enough to allow and adequate reproduction of M1 plants. It was verified that this small inhibitor doses of radiations produced a higher percentage of good variability than the medium and high doses. With the use of small inhibitor doses (GR10-GR20) on the Guadalupe-15 garlic variety, 65 variety plants were obtained., 93.7% out of this number is higher than the control in the indicators considered

  7. Application of x-ray fluorescence (XRF) absolute analysis method for silica refractories

    International Nuclear Information System (INIS)

    Asakura, Hideo; Yamada, Yasujiro; Kansai, Kouhei; Tomatsu, Ichirou; Murata, Mamoru

    2015-01-01

    X-ray fluorescence (XRF) analysis is a rapid and precise quantitative analytical method for the determination of major and trace elements in many industries and academics. XRF analytical values are relative due to the use of the calibration curves calculated from measuring the reference standard materials such as Japanese Refractory Reference Materials (JRRM) series with certified values determined by wet chemical analysis. The development of the XRF analytical method from relative to absolute analysis will help much to determine the absolute values of samples from the fields where reference standard samples have not been prepared, and thus can be applied widely in many industries. The implement of the absolute XRF analysis for silica refractories requires high purity reagents and/or reference standard solution for the binary basic calibration curve, and theoretical matrix correction coefficients for the multi-components silica refractories analysis. The reproducibility and repeatability of this method for Al 2 O 3 5 mass% sample were 0.009 and 0.006 mass% in Al 2 O 3 and showed better values that those of ICP-AES recognized as an absolute method in JIS R 2212-2, which yielded 0.028 and 0.031 mass%, respectively. The XRF absolute analysis for JRRM 200 series, 201a and 205a does not show a bias but coincides with their certified values. (author)

  8. How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?

    International Nuclear Information System (INIS)

    Jones, A. Kyle; Ensor, Joe E.; Pasciak, Alexander S.

    2014-01-01

    Purpose: Skin dosimetry is important for fluoroscopically-guided interventions, as peak skin doses (PSD) that result in skin reactions can be reached during these procedures. There is no consensus as to whether or not indirect skin dosimetry is sufficiently accurate for fluoroscopically-guided interventions. However, measuring PSD with film is difficult and the decision to do so must be madea priori. The purpose of this study was to assess the accuracy of different types of indirect dose estimates and to determine if PSD can be calculated within ±50% using indirect dose metrics for embolization procedures. Methods: PSD were measured directly using radiochromic film for 41 consecutive embolization procedures at two sites. Indirect dose metrics from the procedures were collected, including reference air kerma. Four different estimates of PSD were calculated from the indirect dose metrics and compared along with reference air kerma to the measured PSD for each case. The four indirect estimates included a standard calculation method, the use of detailed information from the radiation dose structured report, and two simplified calculation methods based on the standard method. Indirect dosimetry results were compared with direct measurements, including an analysis of uncertainty associated with film dosimetry. Factors affecting the accuracy of the different indirect estimates were examined. Results: When using the standard calculation method, calculated PSD were within ±35% for all 41 procedures studied. Calculated PSD were within ±50% for a simplified method using a single source-to-patient distance for all calculations. Reference air kerma was within ±50% for all but one procedure. Cases for which reference air kerma or calculated PSD exhibited large (±35%) differences from the measured PSD were analyzed, and two main causative factors were identified: unusually small or large source-to-patient distances and large contributions to reference air kerma from cone

  9. Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, H; Menon, G; Sloboda, R [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2 (Canada); Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-08-15

    The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (∼28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ∼2% for 75 kVp and ∼5% for I-125 seed exposures.

  10. Hematological toxicity in radioimmunotherapy is predicted both by the computed absorbed whole body dose (cGy) and by the administered dose (mCi)

    International Nuclear Information System (INIS)

    Marquez, Sheri D.; Knox, Susan J.; Trisler, Kirk D.; Goris, Michael L.

    1997-01-01

    Purpose/Objective: Radioimmunotherapy (RIT) has yielded encouraging response rates in patients with recurrent non-Hodgkin's lymphoma, but myelotoxicity remains the dose limiting factor. Dose optimization is theoretically possible, since a pretreatment biodistribution study with tracer doses allows for a fairly accurate estimate of the whole body (and by implication the bone marrow) dose in patients. It has been shown that the radiation dose as a function of the administered dose varies widely from patient to patient. The pretreatment study could therefore be used to determine the maximum tolerable dose for each individual patient. The purpose of this study was to examine whether the administered dose or the estimated whole body absorbed radiation dose were indeed predictors of bone marrow toxicity. Materials and Methods: We studied two cohorts of patients to determine if the computed integral whole body or marrow dose is predictive of myelotoxicity. The first cohort consisted of 13 patients treated with Yttrium-90 labeled anti-CD20 (2B8) monoclonal antibody. Those patients were treated in a dose escalation protocol, based on the administered dose, without correction for weight or body surface. The computed whole body dose varied from 41 to 129 cGy. The second cohort (6 patients) were treated with Iodine-131 labeled anti-CD20 (B1) antibody. In this group the administered dose was tailored to deliver an estimated 75 cGy whole body dose. The administered dose varied from 54 to 84 mCi of Iodine-131. For each patient, white blood cell count with differential, hemoglobin, hematocrit, and platelet levels were measured before and at regular intervals after RIT was administered. Using linear regression analysis, a relationship between administered dose, absorbed dose and myelotoxicity was determined for each patient cohort. Results: Marrow toxicity was measured by the absolute decrease in white blood cell (DWBC), platelet (DPLAT), and neutrophil (DN) values. In the Yttrium

  11. Determining the Absolute Configuration of Two Marine Compounds Using Vibrational Chiroptical Spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hopmann, K. H.; Šebestík, Jaroslav; Novotná, J.; Stensen, W.; Urbanová, M.; Svenson, J.; Svendsen, J. S.; Bouř, Petr; Ruud, K.

    2012-01-01

    Roč. 77, č. 2 (2012), s. 858-869 ISSN 0022-3263 R&D Projects: GA ČR GAP208/11/0105; GA MŠk(CZ) LH11033 Institutional research plan: CEZ:AV0Z40550506 Keywords : vibrational circular dichroism * Raman optical activity * absolute configuration * bioprospecting Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 4.564, year: 2012

  12. Dose determination in irradiated chicken meat by ESR method

    International Nuclear Information System (INIS)

    Polat, M.

    1996-01-01

    In this work, the properties of the radicals produced in chicken bones have been investigated by ESR technique to determine the amount of dose applied to the chicken meats during the food irradiation. For this goal, the drumsticks from 6-8 weeks old chickens purchased from a local market were irradiated at dose levels of 0; 2; 4; 6; 8 and 10 kGy. Then, the ESR spectra of the powder samples prepared from the bones of the drumsticks have been investigated. Unirradiated chicken bones have been observed to show a weak ESR signal of single line character. CO-2 ionic radicals of axial symmetry with g=1.9973 and g=2.0025 were observed to be produced in irradiated samples which would give rise to a three peaks ESR spectrum. In addition, the signal intensities of the samples were found to depend linearly on the irradiation dose in the dose range of 0-10 kGy. The powder samples prepared from chicken leg bones cleaned from their meats and marrow and irradiated at dose levels of 1, 2, 3, 4, 5, 6, B, 10, 12,14, 16, 1B, 20 and 22 kGy were used to get the dose-response curve. It was found that this curve has biphasic character and that the dose yield was higher in the 12-1B kGy dose range and a decrease appears in this curve over 18 kGy. The radical produced in the bones were found to be the same whether the irradiation was performed after stripping the meat and removing the marrow from the bone or before the stripping. The ESR spectra of both irradiated and non irradiated samples were investigated in the temperature range of 100 K-450 K and changes in the ESR spectra of CO-2 radical have been studied. For non irradiated samples (controls). the signal intensities were found to decrease when the temperature was increased. The same investigation has been carried out for irradiated samples and it was concluded that the signal intensities relative to the peaks of the radical spectrum increase in the temperature range of 100 K-330 K, then they decrease over 330 K. The change in the

  13. Absolute determination of single-stranded and self-complementary adeno-associated viral vector genome titers by droplet digital PCR.

    Science.gov (United States)

    Lock, Martin; Alvira, Mauricio R; Chen, Shu-Jen; Wilson, James M

    2014-04-01

    Accurate titration of adeno-associated viral (AAV) vector genome copies is critical for ensuring correct and reproducible dosing in both preclinical and clinical settings. Quantitative PCR (qPCR) is the current method of choice for titrating AAV genomes because of the simplicity, accuracy, and robustness of the assay. However, issues with qPCR-based determination of self-complementary AAV vector genome titers, due to primer-probe exclusion through genome self-annealing or through packaging of prematurely terminated defective interfering (DI) genomes, have been reported. Alternative qPCR, gel-based, or Southern blotting titering methods have been designed to overcome these issues but may represent a backward step from standard qPCR methods in terms of simplicity, robustness, and precision. Droplet digital PCR (ddPCR) is a new PCR technique that directly quantifies DNA copies with an unparalleled degree of precision and without the need for a standard curve or for a high degree of amplification efficiency; all properties that lend themselves to the accurate quantification of both single-stranded and self-complementary AAV genomes. Here we compare a ddPCR-based AAV genome titer assay with a standard and an optimized qPCR assay for the titration of both single-stranded and self-complementary AAV genomes. We demonstrate absolute quantification of single-stranded AAV vector genomes by ddPCR with up to 4-fold increases in titer over a standard qPCR titration but with equivalent readout to an optimized qPCR assay. In the case of self-complementary vectors, ddPCR titers were on average 5-, 1.9-, and 2.3-fold higher than those determined by standard qPCR, optimized qPCR, and agarose gel assays, respectively. Droplet digital PCR-based genome titering was superior to qPCR in terms of both intra- and interassay precision and is more resistant to PCR inhibitors, a desirable feature for in-process monitoring of early-stage vector production and for vector genome biodistribution

  14. Dose rate determining factors of PWR primary water

    International Nuclear Information System (INIS)

    Terachi, Takumi; Kuge, Toshiharu; Nakano, Nobuo

    2014-01-01

    The relationship between dose rate trends and water chemistry has been studied to clarify the determining factors on the dose rates. Therefore dose rate trends and water chemistry of 11 PWR plants of KEPCO (Kansai Electric Power Co., Inc.) were summarized. It is indicated that the chemical composition of the oxide film, behaviour of corrosion products and Co-58/Co-60 ratio in the primary system have effected dose rate trends based on plant operation experiences for over 40 years. According to plant operation experiences, the amount of Co-58 has been decreasing with the increasing duration of SG (Steam Generator) usage. It is indicated that the stable oxide film formation on the inner surface of SG tubing, is a major beneficial factor for radiation sources reduction. On the other hand, the reduction of the amount of Co-60 for the long term has been not clearly observed especially in particular high dose plants. The primary water parameters imply that considering release and purification balance on Co-59 is important to prevent accumulation of source term in primary water. In addition, the effect of zinc injection, which relates to the chemical composition of oxide film, was also assessed. As the results, the amount of radioactive Co has been clearly decreased. The decreasing trend seems to correlate to the half-life of Co-60, because it is considered that the injected zinc prevents the uptake of radioactive Co into the oxide film on the inner surface of the components and piping. In this paper, the influence of water chemistry and the replacement experiences of materials on the dose rates were discussed. (author)

  15. Neutron activation analysis of certified samples by the absolute method

    Science.gov (United States)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  16. The relative importance of perceptual and memory sampling processes in determining the time course of absolute identification.

    Science.gov (United States)

    Guest, Duncan; Kent, Christopher; Adelman, James S

    2018-04-01

    In absolute identification, the extended generalized context model (EGCM; Kent & Lamberts, 2005, 2016) proposes that perceptual processing determines systematic response time (RT) variability; all other models of RT emphasize response selection processes. In the EGCM-RT the bow effect in RTs (longer responses for stimuli in the middle of the range) occurs because these middle stimuli are less isolated, and as perceptual information is accumulated, the evidence supporting a correct response grows more slowly than for stimuli at the ends of the range. More perceptual information is therefore accumulated in order to increase certainty in response for middle stimuli, lengthening RT. According to the model reducing perceptual sampling time should reduce the size of the bow effect in RT. We tested this hypothesis in 2 pitch identification experiments. Experiment 1 found no effect of stimulus duration on the size of the RT bow. Experiment 2 used multiple short stimulus durations as well as manipulating set size and stimulus spacing. Contrary to EGCM-RT predictions, the bow effect on RTs was large for even very short durations. A new version of the EGCM-RT could only capture this, alongside the effect of stimulus duration on accuracy, by including both a perceptual and a memory sampling process. A modified version of the selective attention, mapping, and ballistic accumulator model (Brown, Marley, Donkin, & Heathcote, 2008) could also capture the data, by assuming psychophysical noise diminishes with increased exposure duration. This modeling suggests systematic variability in RT in absolute identification is largely determined by memory sampling and response selection processes. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  17. Evolution of the excess absolute risk (EAR) in the Valencian breast cancer screening programme

    International Nuclear Information System (INIS)

    Ferrer, S.; Ramos, M.; Villaescusa, J. I.; Verdu, G.; Salas, M. D.; Cuevas, M. D.

    2004-01-01

    Breast cancer is one of the most frequent diseases in women, with a high incidence rate. The best fight against the breast cancer is the early detection by menas of mammograms in a screening programme. The Valencian Breast Cancer Screening Programme (VBCSP) started at 1992, and it is composed of twenty-two mammography units. The programme is targeted towards asympotomatic women dfrom 45 to 69 years old, but this screening has a negative influence in the studied woman, whatever the diagnosis was. By means of MCNP-4c2 Monte Carlo code, some conversion factors from air kerma air kerma to glandular dose have been developed. Different breast woamn models, according to the Valencian brest anathomy (taking into account the relation breast radius / breast compression thickness obtained from real samples, have been simulated in order to obtain the glandular breast dose values. Quality control parameters as ESAK values were also employed for developing the methods. The conversion factors give a simple and fast wasy to obtain the mean glandular dose from mammography exposition parameters. The glandular dose has been also calculated following the European Protocol on Dosimetry in order to compare the results of the new methodology. Four sample populations of 100 omen from each uunit of the VBCSP have been taken innnn order to estimate the mean glandular dose and the associated excess absolute risk (EAR). Once the doses for each woman from the samples are obtained and according to the age of them, the EAR value for each sample has been determinated following the UNSCEAR 2000 projection risk model, which takes into account the characteristics of the Valencian population and gives the EAR for radio-induced breast cancer. The results have been calculated and compared by means of the ASQRAD software, but with an older risk projection model, the UNSCEAR 1994. Once the four sample average EAR have been calculated, the evolution of the induced risk in the Valencian Breast Cancer

  18. Dose determination of 600 MeV proton irradiated specimens

    International Nuclear Information System (INIS)

    Gavillet, D.

    1991-01-01

    The calculation method for the experimental determination of the atomic production cross section from the γ activity measurements are presented. This method is used for the determination of some isotope production cross sections for 600 MeV proton irradition in MANET steel, copper, tungsten, gold and titanium. The results are compared with some calculation. These values are used to determine the dose of specimens irradiated in the PIREX II facility. The results are discussed in terms of the irradiation parameters. A guide for the use of the production cross section determined in the dosimetry experiment are given. (author) tabs., refs

  19. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  20. Absolute activity determinations on large volume geological samples independent of self-absorption effects

    International Nuclear Information System (INIS)

    Wilson, W.E.

    1980-01-01

    This paper describes a method for measuring the absolute activity of large volume samples by γ-spectroscopy independent of self-absorption effects using Ge detectors. The method yields accurate matrix independent results at the expense of replicative counting of the unknown sample. (orig./HP)

  1. Determination of the absolute two-photon ionization cross section of He by an XUV free electron laser

    International Nuclear Information System (INIS)

    Sato, Takahiro; Iwasaki, Atsushi; Ishibashi, Kazuki; Okino, Tomoya; Yamanouchi, Kaoru; Adachi, Junichi; Yagishita, Akira; Yazawa, Hiroki; Aoyma, Makoto; Yabashi, Makina; Nagasono, Mitsuru; Higashiya, Atsushi; Ishikawa, Tetsuya; Kannari, Fumihiko; Yamakawa, Koichi; Midorikawa, Katsumi; Nakano, Hidetoshi

    2011-01-01

    The resonant and non-resonant two-photon single ionization processes of He were investigated using intense free electron laser light in the extreme ultraviolet (XUV) region (53.4-61.4 nm) covering the 1s-2p and 1s-3p resonant transitions of He. On the basis of the dependences of the yield of He + on the XUV light-field intensity at 53.4, 58.4, 56.0 and 61.4 nm, the absolute values of the two-photon ionization cross sections of He at the four different wavelengths and their dependence on the light-field intensity were determined for the first time. (fast track communication)

  2. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  3. Identification of absolute conversion to geraldol from fisetin and pharmacokinetics in mouse.

    Science.gov (United States)

    Jo, Jun Hyeon; Jo, Jung Jae; Lee, Jae-Mok; Lee, Sangkyu

    2016-12-01

    Fisetin (3,3',4',7-tetrahydroxyflavone) is a flavonoid found in several fruits, vegetables, nuts, and wine and has anti-oxidant, anti-inflammatory, and anti-angiogenic properties. Geraldol is the 3'-methoxylated metabolite of fisetin (3,4',7-trihydroxy-3'-methoxyflavone). The concentration of fisetin and geraldol in mouse plasma was determined by LC-MS/MS, following direct protein precipitation. These concentrations were determined after administration of fisetin at doses of 2mg/kg (i.v.) and 100 and 200mg/kg (p.o.). The method was validated in terms of linearity, accuracy, precision, matrix effect, and stability. The pharmacokinetics parameters of fisetin and geraldol were successfully determined using a validated method in mice. Results indicated that fisetin was very rapidly methylated to geraldol in vivo. Following administration of fisetin, it was observed that the C max and AUC values for geraldol were higher than those of fisetin. The absolute bioavailability of fisetin was calculated as 7.8% and 31.7% after oral administration of 100 and 200mg/kg fisetin, respectively. This method was successfully applied to determine the pharmacokinetic parameters of fisetin and its main metabolite geraldol in mouse plasma. Geraldol was the dominant circulating metabolite after fisetin administration in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. New absolute paleointensity determinations for the Permian-Triassic boundary from the Kuznetsk Trap Basalts.

    Science.gov (United States)

    Kulakov, E.; Metelkin, D. V.; Kazansky, A.

    2015-12-01

    We report the results of a pilot absolute paleointensity study of the ~250 Ma basalts of Kuznetsk traps (Kuznetsk Basin, Altai-Sayan folded area). Studied samples are characterized by a reversed polarity of natural remanent magnetization that corresponds to the lower part of Siberian Trap basalts sequence. Geochemical similarity of Kuznets basalts with those from Norilsk region supports this interpretation. Primary origin of thermal remanence in our sample is confirmed by a positive backed contact test. Rock magnetic analyses indicate that the ChRM is carried by single-domain titanomagnetite. The Coe-version of the Thellier-Therllier double-heating method was utilized for the paleointensity determinations. In contrast to the previous studies of the Permian-Triassic Siberian trap basalts, our data indicate that by the P-T boundary the paleofield intensity was relatively high and comparable with geomagnetic field strength for the last 10 millions of years. New results question the duration of the "Mesozoic dipole-low".

  5. Thermodynamics of negative absolute pressures

    International Nuclear Information System (INIS)

    Lukacs, B.; Martinas, K.

    1984-03-01

    The authors show that the possibility of negative absolute pressure can be incorporated into the axiomatic thermodynamics, analogously to the negative absolute temperature. There are examples for such systems (GUT, QCD) processing negative absolute pressure in such domains where it can be expected from thermodynamical considerations. (author)

  6. Development and verification of an analytical algorithm to predict absorbed dose distributions in ocular proton therapy using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Koch, Nicholas C; Newhauser, Wayne D

    2010-01-01

    Proton beam radiotherapy is an effective and non-invasive treatment for uveal melanoma. Recent research efforts have focused on improving the dosimetric accuracy of treatment planning and overcoming the present limitation of relative analytical dose calculations. Monte Carlo algorithms have been shown to accurately predict dose per monitor unit (D/MU) values, but this has yet to be shown for analytical algorithms dedicated to ocular proton therapy, which are typically less computationally expensive than Monte Carlo algorithms. The objective of this study was to determine if an analytical method could predict absolute dose distributions and D/MU values for a variety of treatment fields like those used in ocular proton therapy. To accomplish this objective, we used a previously validated Monte Carlo model of an ocular nozzle to develop an analytical algorithm to predict three-dimensional distributions of D/MU values from pristine Bragg peaks and therapeutically useful spread-out Bragg peaks (SOBPs). Results demonstrated generally good agreement between the analytical and Monte Carlo absolute dose calculations. While agreement in the proximal region decreased for beams with less penetrating Bragg peaks compared with the open-beam condition, the difference was shown to be largely attributable to edge-scattered protons. A method for including this effect in any future analytical algorithm was proposed. Comparisons of D/MU values showed typical agreement to within 0.5%. We conclude that analytical algorithms can be employed to accurately predict absolute proton dose distributions delivered by an ocular nozzle.

  7. Effects of 14-day oral low dose selenium nanoparticles and selenite in rat—as determined by metabolite pattern determination

    DEFF Research Database (Denmark)

    Hadrup, Niels; Löschner, Katrin; Skov, Kasper

    2016-01-01

    Selenium (Se) is an essential element with a small difference between physiological and toxic doses. To provide more effective and safe Se dosing regimens, as compared to dosing with ionic selenium, nanoparticle formulations have been developed. However, due to the nano-formulation, unexpected...... toxic effects may occur. We used metabolite pattern determination in urine to investigate biological and/or toxic effects in rats administered nanoparticles and for comparison included ionic selenium at an equimolar dose in the form of sodium selenite. Low doses of 10 and 100 fold the recommended human...

  8. Continuous dose-response relationship of the LDL-cholesterol-lowering effect of phytosterol intake.

    Science.gov (United States)

    Demonty, Isabelle; Ras, Rouyanne T; van der Knaap, Henk C M; Duchateau, Guus S M J E; Meijer, Linsie; Zock, Peter L; Geleijnse, Johanna M; Trautwein, Elke A

    2009-02-01

    Phytosterols (plant sterols and stanols) are well known for their LDL-cholesterol (LDL-C)-lowering effect. A meta-analysis of randomized controlled trials in adults was performed to establish a continuous dose-response relationship that would allow predicting the LDL-C-lowering efficacy of different phytosterol doses. Eighty-four trials including 141 trial arms were included. A nonlinear equation comprising 2 parameters (the maximal LDL-C lowering and an incremental dose step) was used to describe the dose-response curve. The overall pooled absolute (mmol/L) and relative (%) LDL-C-lowering effects of phytosterols were also assessed with a random effects model. The pooled LDL-C reduction was 0.34 mmol/L (95% CI: -0.36, -0.31) or 8.8% (95% CI: -9.4, -8.3) for a mean daily dose of 2.15 g phytosterols. The impacts of subject baseline characteristics, food formats, type of phytosterols, and study quality on the continuous dose-response curve were determined by regression or subgroup analyses. Higher baseline LDL-C concentrations resulted in greater absolute LDL-C reductions. No significant differences were found between dose-response curves established for plant sterols vs. stanols, fat-based vs. non fat-based food formats and dairy vs. nondairy foods. A larger effect was observed with solid foods than with liquid foods only at high phytosterol doses (>2 g/d). There was a strong tendency (P = 0.054) towards a slightly lower efficacy of single vs. multiple daily intakes of phytosterols. In conclusion, the dose-dependent LDL-C-lowering efficacy of phytosterols incorporated in various food formats was confirmed and equations of the continuous relationship were established to predict the effect of a given phytosterol dose. Further investigations are warranted to investigate the impact of solid vs. liquid food formats and frequency of intake on phytosterol efficacy.

  9. High-dose preoperative chemoradiotherapy in esophageal cancer patients does not increase postoperative pulmonary complications: Correlation with dose-volume histogram parameters

    International Nuclear Information System (INIS)

    Hurmuzlu, Meysan; Ovrebo, Kjell; Wentzel-Larsen, Tore; Muren, Ludvig Paul; Viste, Asgaut; Smaaland, Rune

    2010-01-01

    Purpose: To investigate the association of high-dose preoperative chemoradiotherapy (CRT) and dose-volume histogram (DVH) parameters of lungs with incidence of postoperative pulmonary complications and to identify predictive clinical factors of pulmonary complications. Methods: Data of 65 patients were collected retrospectively. Thirty-five patients underwent transthoracic esophagectomy (TTE) alone and 30 received cisplatin and 5-fluorouracil, concomitant with radiotherapy, median dose 66 Gy, and followed by TTE. From the DVH for each lung alone and for both lungs together as one organ we generated total lung volume, mean radiotherapy dose, relative and absolute volumes receiving more than a threshold dose, and relative and absolute volumes receiving less than a threshold dose. Postoperative pulmonary complications were defined as pneumonia or respiratory failure. Results: Sixty percent of the patients in the TTE alone group had postoperative pulmonary complications versus 63% in the CRT + TTE group. Postoperative mortality was 8.6% and 16.7% in the respective patient groups (p = NS). None of the DVH parameters was associated with postoperative pulmonary complications. Squamous cell carcinoma was an adverse factor related to increased postoperative pulmonary complications. Conclusion: High-dose preoperative CRT was not associated with increased postoperative pulmonary complications in this cohort of esophageal cancer patients.

  10. Determination of absorbed dose in reactors

    International Nuclear Information System (INIS)

    1971-01-01

    There are many areas in the use and operation of research reactors where the absorbed dose and the neutron fluence are required. These include work on the determination of the radiolytic stability of the coolant and moderator and on the determination of radiation damage in structural materials, and reactor experiments involving radiation chemistry and radiation biology. The requirements range from rough estimates of the total heating due to radiation to precise values specifying the contributions of gamma rays, thermal neutrons and fast neutrons. To meet all these requirements a variety of experimental measurements and calculations as well as a knowledge of reactor radiations and their interactions is necessary. Realizing the complexity and importance of this field, its development at widely separated laboratories and the need to bring the experts in this work together, the IAEA has convened three panel meetings. These were: 'In-pile dosimetry', held in July 1964 (published by the Agency as Technical Reports Series No. 46); 'Neutron fluence measurements', in October 1965; and 'In-pile dosimetry', in November 1966. The recommendations of these three panels led the Agency to form a Working Group on Reactor Radiation Measurements and to commission the writing of this book and a book on Neutron Fluence Measurements. The latter was published in May 1970 (Technical Reports Series No. 107). The material on neutron fluence and absorbed dose measurements is widely scattered in reports and reviews. It was considered that it was time for all relevant information to be evaluated and put together in the form of a practical guide that would be valuable both to experienced workers and beginners in the field

  11. Absolute determination of thyroid activity from profile scans. Description of a correction method for extra-thyroidal activity of the neck. , pt. 2

    International Nuclear Information System (INIS)

    Damme, K.J. van

    1977-01-01

    An absolute method to measure the uptake of radioactive iodide by the thyroid by making a profile scan across the thyroid region with a slit-collimated detector is described. It is well known that the extra-thyroidal activity (ETA) in the neck may constitute a severe hindrance to measure the uptake accurately, especially in cases of hypothyroidism and often during the first few hours after the administration of the traces dose (e.g. orally 0.5 μCiNa 131 I). The author's approach to the problem is presented. A practical application of the method is discussed in extenso. A comparative evaluation of the usability of 123 I and 131 I as least-burdening radionuclides for child patients is given at the end

  12. A multicentre audit of HDR/PDR brachytherapy absolute dosimetry in association with the INTERLACE trial (NCT015662405)

    Science.gov (United States)

    Díez, P.; Aird, E. G. A.; Sander, T.; Gouldstone, C. A.; Sharpe, P. H. G.; Lee, C. D.; Lowe, G.; Thomas, R. A. S.; Simnor, T.; Bownes, P.; Bidmead, M.; Gandon, L.; Eaton, D.; Palmer, A. L.

    2017-12-01

    A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre’s treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60Co source, (Co0.A86). Alanine measurements when compared to the centres’ calculated dose showed a mean difference (±SD) of  +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%-4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.

  13. Absolute calibration of TFTR helium proportional counters

    International Nuclear Information System (INIS)

    Strachan, J.D.; Diesso, M.; Jassby, D.; Johnson, L.; McCauley, S.; Munsat, T.; Roquemore, A.L.; Loughlin, M.

    1995-06-01

    The TFTR helium proportional counters are located in the central five (5) channels of the TFTR multichannel neutron collimator. These detectors were absolutely calibrated using a 14 MeV neutron generator positioned at the horizontal midplane of the TFTR vacuum vessel. The neutron generator position was scanned in centimeter steps to determine the collimator aperture width to 14 MeV neutrons and the absolute sensitivity of each channel. Neutron profiles were measured for TFTR plasmas with time resolution between 5 msec and 50 msec depending upon count rates. The He detectors were used to measure the burnup of 1 MeV tritons in deuterium plasmas, the transport of tritium in trace tritium experiments, and the residual tritium levels in plasmas following 50:50 DT experiments

  14. Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams

    International Nuclear Information System (INIS)

    Pedroni, E; Scheib, S; Boehringer, T; Coray, A; Grossmann, M; Lin, S; Lomax, A

    2005-01-01

    In this paper we present the pencil beam dose model used for treatment planning at the PSI proton gantry, the only system presently applying proton therapy with a beam scanning technique. The scope of the paper is to give a general overview on the various components of the dose model, on the related measurements and on the practical parametrization of the results. The physical model estimates from first physical principles absolute dose normalized to the number of incident protons. The proton beam flux is measured in practice by plane-parallel ionization chambers (ICs) normalized to protons via Faraday-cup measurements. It is therefore possible to predict and deliver absolute dose directly from this model without other means. The dose predicted in this way agrees very well with the results obtained with ICs calibrated in a cobalt beam. Emphasis is given in this paper to the characterization of nuclear interaction effects, which play a significant role in the model and are the major source of uncertainty in the direct estimation of the absolute dose. Nuclear interactions attenuate the primary proton flux, they modify the shape of the depth-dose curve and produce a faint beam halo of secondary dose around the primary proton pencil beam in water. A very simple beam halo model has been developed and used at PSI to eliminate the systematic dependences of the dose observed as a function of the size of the target volume. We show typical results for the relative (using a CCD system) and absolute (using calibrated ICs) dosimetry, routinely applied for the verification of patient plans. With the dose model including the nuclear beam halo we can predict quite precisely the dose directly from treatment planning without renormalization measurements, independently of the dose, shape and size of the dose fields. This applies also to the complex non-homogeneous dose distributions required for the delivery of range-intensity-modulated proton therapy, a novel therapy technique

  15. Towards absolute neutrino masses

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory 106-38, Caltech, Pasadena, CA 91125 (United States)

    2007-06-15

    Various ways of determining the absolute neutrino masses are briefly reviewed and their sensitivities compared. The apparent tension between the announced but unconfirmed observation of the 0{nu}{beta}{beta} decay and the neutrino mass upper limit based on observational cosmology is used as an example of what could happen eventually. The possibility of a 'nonstandard' mechanism of the 0{nu}{beta}{beta} decay is stressed and the ways of deciding which of the possible mechanisms is actually operational are described. The importance of the 0{nu}{beta}{beta} nuclear matrix elements is discussed and their uncertainty estimated.

  16. Determination of the absolute second-order rate constant for the reaction Na + O3 → NaO + O2

    International Nuclear Information System (INIS)

    Husain, David; Marshall, Paul; Plane, J.M.C.

    1985-01-01

    The absolute second-order rate constant for the reaction Na + O 3 -> NaO + O 2 (k 1 ) has been determined by time-resolved atomic resonance absorption spectroscopy at lambda = 589 nm [Na(3 2 Psub(j)) 2 Ssub(1/2))] following pulsed irradiation, coupled with monitoring of O 3 by light absorption in the ultra-violet; this yields k 1 (500 K) = 4(+4,-2) x 10 -10 cm 3 molecule -1 s -1 , resolving large differences for various estimates of this important quantity used in modelling the sodium layer in the mesosphere. (author)

  17. Absolute measurement of 85Sr

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Watanabe, Tamaki

    1978-01-01

    An extension of 4πe.x-γ coincidence technique is described to measure the absolute disintegration rate of 85 Sr. This nuclide shows electron capture-gamma decay, and 514keV level of 85 Rb is a meta-stable state with half life of 0.958 μsec. Therefore, the conventional 4 πe.x-γ coincidence technique with about 1 μsec of resolution time can not be applied to this nuclide. To measure the absolute disintegration rate of this, the delayed 4 πe.x-γ coincidence technique with two different resolution time has been used. The disintegration rate was determined from four counting rates of electron-x ray, gamma ray and two coincidences, and the true disintegration rate could be obtained by extraporation of the electron-x ray detection efficiency to 1. Two resolution time appearing in the calculation formulas were determined from the chance coincidence between electron-x ray and delayed gamma ray signals. When the coincidence countings with three different resolution time were carried out by one coincidence circuit, the results calculated from all combinations did not agree each other. However, when the two coincidence circuits of the same type were used to fix the resolution time, a good coincidence absorption function was obtained and the disintegration rate was determined with accuracy of +- 0.5%. To evaluate the validity of the results the disintegration rates were measured by two NaI (Tl) scintillation detectors whose gamma-ray detection efficiency was previously determined and both results were agreed within accuracy of +- 0.5%. This method can be applied with nearly same accuracy for the beta-gamma decay nuclide possessing a meta-stable state of the half life below about 10 μsec. (auth.)

  18. Determination the lethal dose of ascaris lumbricoides ova by gamma irradiation

    International Nuclear Information System (INIS)

    Shamma, M.; Al-Adawi, M.; Sharabi, N.

    2002-11-01

    The lethal gamma irradiation dose of ascaris lumbricoides which collected from Damascus Sewage water Plant was determined. Ascaris lumbricoides ova were treated with several gamma irradiation doses with (0.1, 0.2, 0.3, 0.4,...and 1.5 KGy). No morphological changes were observed on the eggs when directly examined microscopically after irradiation. However after two weeks of incubation at 37 degree centigrade the cell contents of the eggs which irradiated with 0.5 KGy and beyond were fragmented and scattered in the whole eggs and no larvae were observed after eight weeks of incubation. It is concluded that the dose 0.5 my be considered as the dose of choice if sewage water is to be treated by gamma rays. (author)

  19. Determination the lethal dose of ascaris lumbricoides ova by gamma irradiation

    CERN Document Server

    Shamma, M A; Sharabi, N

    2002-01-01

    The lethal gamma irradiation dose of ascaris lumbricoides which collected from Damascus Sewage water Plant was determined. Ascaris lumbricoides ova were treated with several gamma irradiation doses with (0.1, 0.2, 0.3, 0.4,...and 1.5 KGy). No morphological changes were observed on the eggs when directly examined microscopically after irradiation. However after two weeks of incubation at 37 degree centigrade the cell contents of the eggs which irradiated with 0.5 KGy and beyond were fragmented and scattered in the whole eggs and no larvae were observed after eight weeks of incubation. It is concluded that the dose 0.5 my be considered as the dose of choice if sewage water is to be treated by gamma rays.

  20. Methods of determining the effective dose in dental radiology

    International Nuclear Information System (INIS)

    Thilander-Klang, A.; Helmrot, E.

    2010-01-01

    A wide variety of X-ray equipment is used today in dental radiology, including intra-oral, ortho-pan-tomographic, cephalo-metric, cone-beam computed tomography (CBCT) and computed tomography (CT). This raises the question of how the radiation risks resulting from different kinds of examinations should be compared. The risk to the patient is usually expressed in terms of effective dose. However, it is difficult to determine its reliability, and it is difficult to make comparisons, especially when different modalities are used. The classification of the new CBCT units is also problematic as they are sometimes classified as CT units. This will lead to problems in choosing the best dosimetric method, especially when the examination geometry resembles more on an ordinary ortho-pan-tomographic examination, as the axis of rotation is not at the centre of the patient, and small radiation field sizes are used. The purpose of this study was to present different methods for the estimation of the effective dose from the equipment currently used in dental radiology, and to discuss their limitations. The methods are compared based on commonly used measurable and computable dose quantities, and their reliability in the estimation of the effective dose. (authors)

  1. Committed effective dose determination in cereal flours by gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Scheibel, Viviane

    2006-01-01

    The health impact from radionuclides ingestion of foodstuffs was evaluated by the committed effective doses determined in commercial samples of South-Brazilian cereal flours (soy, wheat, corn, manioc, rye, oat, barley and rice flour). The radioactivity traces of 228 Th, 228 Ra, 226 Ra, 40 K, 7 Be and 137 Cs were measured by gamma-ray spectrometry employing a 66% relative efficiency HPGe detector. The energy resolution for the 1332.46 keV line of 60 Co was 2.03 keV. The committed effective doses were calculated with the activities analyzed in the present flour samples, the foodstuff rates of consumption (Brazilian Institute of Geography and Statistics) and the ingestion dose coefficients (International Commission of Radiological Protection). The reliability median activities were verified with χ 2 tests, assuring the fittings quality. The highest concentration levels of 228 Th and 40 K were 3.5 ± 0.4 and 1469 ± 17 Bq.kg -1 for soy flour, respectively, with 95% of confidence level. The lower limit of detection for 137 Cs ranged from 0.04 to 0.4 Bq.kg -1 . The highest committed effective dose was 0.36 μSv.y -1 for 228 Ra in manioc flour (adults). All committed effective doses determined at the present work were lower than the UNSCEAR limits of 140 μSv.y -1 and much lower than the ICRP (1991) limits of 1 mSv.y -1 , for general public. There are few literature references for natural and artificial radionuclides in foodstuffs and mainly for committed effective doses. This work brings the barley flour data, which is not present at the literature and 7 Be data which is not encountered in foodstuffs at the literature, besides all the other flours data information about activities and committed effective doses. (author)

  2. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2015-09-01

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D PMMA (10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K a obtaining a value of 1.20 Sv Gy -1 with a u c = 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy -1 with a u c = 2%. (Author)

  3. Doses determination in UCCA treatments with LDR brachytherapy using Monte Carlo methods

    International Nuclear Information System (INIS)

    Benites R, J. L.; Vega C, H. R.

    2017-10-01

    Using Monte Carlo methods, with the code MCNP5, a gynecological mannequin and a vaginal cylinder were modeled. The spatial distribution of absorbed dose rate in uterine cervical cancer (UCCA) treatments was determined under the modality of manual brachytherapy of low dose rate (B-LDR). The design of the model included the gynecological liquid water mannequin, a vaginal cylinder applicator of Lucite (PMMA) with hemisphere termination. The applicator was formed by a vaginal cylinder 10.3 cm long and 2 cm in diameter. This cylinder was mounted on a stainless steel tube 15.2 cm long by 0.6 cm in diameter. A linear array of four radioactive sources of Cesium 137 was inserted into the tube. 13 water cells of 0.5 cm in diameter were modeled around the vaginal cylinder and the absorbed dose was calculated in these. The distribution of the fluence of gamma photons in the mesh was calculated. It was found that the distribution of the absorbed dose is symmetric for cells located in the upper and lower part of the vaginal cylinder. The values of the absorbed dose rate were estimated for the date of manufacture of the sources. This result allows the use of the law of radioactive decay to determine the dose rate at any date of a gynecological treatment of B-LDR. (Author)

  4. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  5. Danish Towns during Absolutism

    DEFF Research Database (Denmark)

    This anthology, No. 4 in the Danish Urban Studies Series, presents in English recent significant research on Denmark's urban development during the Age of Absolutism, 1660-1848, and features 13 articles written by leading Danish urban historians. The years of Absolutism were marked by a general...

  6. Detection of atomic and molecular hydrogen in post-discharge by resonant multi-photo-ionisation. Determination of absolute atomic densities

    International Nuclear Information System (INIS)

    Persuy, Philippe

    1990-01-01

    Within the frame of studies on devices for physical vapour deposition, and on phenomena leading to these depositions, this research thesis reports the development of a laser-diagnosis based on the phenomenon of resonant multi-photo-ionisation, and an attempt to obtain from it values of the absolute concentration of atomic hydrogen. After some recalls on the diversity of multi-photon phenomena, their theoretical and experimental evolutions, and on the particular role of hydrogen, the author reports experiments performed at 307.7 and 364.7 nm which respectively addressed the post-discharge detection of molecular hydrogen and of atomic hydrogen. A model is presented which addresses the interaction volume, and results of experiments of atom multi-photo-ionisation are reported. One of the results of this model is an assessment of the cross-section of the excitation with three photons of the hydrogen atom. This result is then used to determine the absolute density of atoms in fundamental state for different discharge conditions. Finally, the author presents the calculation software and some curve examples displaying the evolution of the number of ions and of excited states within the interaction volume [fr

  7. Concepts for dose determination in flat-detector CT

    Science.gov (United States)

    Kyriakou, Yiannis; Deak, Paul; Langner, Oliver; Kalender, Willi A.

    2008-07-01

    Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDIL=100 mm, where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm × 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDIL determination with respect to the desired CTDI∞. Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of >=600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of >=600 mm appeared to be necessary to approximate CTDI∞ in within 1%. MC simulations

  8. Absolute photoionization cross-section of the methyl radical.

    Science.gov (United States)

    Taatjes, Craig A; Osborn, David L; Selby, Talitha M; Meloni, Giovanni; Fan, Haiyan; Pratt, Stephen T

    2008-10-02

    The absolute photoionization cross-section of the methyl radical has been measured using two completely independent methods. The CH3 photoionization cross-section was determined relative to that of acetone and methyl vinyl ketone at photon energies of 10.2 and 11.0 eV by using a pulsed laser-photolysis/time-resolved synchrotron photoionization mass spectrometry method. The time-resolved depletion of the acetone or methyl vinyl ketone precursor and the production of methyl radicals following 193 nm photolysis are monitored simultaneously by using time-resolved synchrotron photoionization mass spectrometry. Comparison of the initial methyl signal with the decrease in precursor signal, in combination with previously measured absolute photoionization cross-sections of the precursors, yields the absolute photoionization cross-section of the methyl radical; sigma(CH3)(10.2 eV) = (5.7 +/- 0.9) x 10(-18) cm(2) and sigma(CH3)(11.0 eV) = (6.0 +/- 2.0) x 10(-18) cm(2). The photoionization cross-section for vinyl radical determined by photolysis of methyl vinyl ketone is in good agreement with previous measurements. The methyl radical photoionization cross-section was also independently measured relative to that of the iodine atom by comparison of ionization signals from CH3 and I fragments following 266 nm photolysis of methyl iodide in a molecular-beam ion-imaging apparatus. These measurements gave a cross-section of (5.4 +/- 2.0) x 10(-18) cm(2) at 10.460 eV, (5.5 +/- 2.0) x 10(-18) cm(2) at 10.466 eV, and (4.9 +/- 2.0) x 10(-18) cm(2) at 10.471 eV. The measurements allow relative photoionization efficiency spectra of methyl radical to be placed on an absolute scale and will facilitate quantitative measurements of methyl concentrations by photoionization mass spectrometry.

  9. Determination of absorbed dose to the lens of eye from external sources

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-01-01

    The methods of determining absorbed dose distributions in human eyeball by means of the experiments and available theories have been reported. A water phantom was built up. The distributions of beta dose were measured by an extrapolation ionization chamber at some depths corresponding to components of human eyeball such as cornea, sclera, anterior chamber and the lens of eye. The ratios among superficial absorbed dose (at 0.07 mm) and average absorbed doses at the depths 1,2,3 mm are obtained. They can be used for confining the deterministic effects of superficial tissues and organs such as the lens of eye for weakly penetrating radiations

  10. Effect of Absolute From Hibiscus syriacus L. Flower on Wound Healing in Keratinocytes

    Science.gov (United States)

    Yoon, Seok Won; Lee, Kang Pa; Kim, Do-Yoon; Hwang, Dae Il; Won, Kyung-Jong; Lee, Dae Won; Lee, Hwan Myung

    2017-01-01

    Background: Proliferation and migration of keratinocytes are essential for the repair of cutaneous wounds. Hibiscus syriacus L. has been used in Asian medicine; however, research on keratinocytes is inadequate. Objective: To establish the dermatological properties of absolute from Hibiscus syriacus L. flower (HSF) and to provide fundamental research for alternative medicine. Materials and Methods: We identified the composition of HSF absolute using gas chromatography-mass spectrometry analysis. We also examined the effect of HSF absolute in HaCaT cells using the XTT assay, Boyden chamber assay, sprout-out growth assay, and western blotting. We conducted an in-vivo wound healing assay in rat tail-skin. Results: Ten major active compounds were identified from HSF absolute. As determined by the XTT assay, Boyden chamber assay, and sprout-out growth assay results, HSF absolute exhibited similar effects as that of epidermal growth factor on the proliferation and migration patterns of keratinocytes (HaCaT cells), which were significantly increased after HSF absolute treatment. The expression levels of the phosphorylated signaling proteins relevant to proliferation, including extracellular signal-regulated kinase 1/2 (Erk 1/2) and Akt, were also determined by western blot analysis. Conclusion: These results of our in-vitro and ex-vivo studies indicate that HSF absolute induced cell growth and migration of HaCaT cells by phosphorylating both Erk 1/2 and Akt. Moreover, we confirmed the wound-healing effect of HSF on injury of the rat tail-skin. Therefore, our results suggest that HSF absolute is promising for use in cosmetics and alternative medicine. SUMMARY Hisbiscus syriacus L. flower absolute increases HaCaT cell migration and proliferation.Hisbiscus syriacus L. flower absolute regulates phosphorylation of ERK 1/2 and Akt in HaCaT cell.Treatment with Hisbiscus syriacus L. flower induced sprout outgrowth.The wound in the tail-skin of rat was reduced by Hisbiscus syriacus

  11. The determination of patient dose from 18F-FDG PET/CT examination

    International Nuclear Information System (INIS)

    Khamwan, K.; Krisanachinda, A.; Pasawang, P.

    2010-01-01

    The use of positron emission tomography/computed tomography (PET/CT) system has heightened the need for medical diagnosis. However, the patient dose is increasing in comparison to whole-body PET/CT dose. The aim of this study is to determine the patient effective dose in 35 oncology Thai patients with the age range of 28-60 y from PET scan using [fluorine-18]-fluoro-2-deoxy-D-glucose and from CT scan. Cumulated activity and residence time of various organs were calculated from time-activity curves by using S-value based on the body mass. Mean organ absorbed dose and the effective dose from CT scan were calculated using the Medical Internal Radiation Dosimetry method and Monte Carlo simulation, respectively. The average whole-body effective doses from PET and CT were 4.40 ± 0.61 and 14.45 ± 2.82 mSv, respectively, resulting in the total patient dose of 18.85 mSv. This can be used as the reference dose in Thai patients. (authors)

  12. Objective method to report planner-independent skin/rib maximal dose in balloon-based high dose rate (HDR) brachytherapy for breast cancer

    International Nuclear Information System (INIS)

    Kim, Yongbok; Trombetta, Mark G.

    2011-01-01

    Purpose: An objective method was proposed and compared with a manual selection method to determine planner-independent skin and rib maximal dose in balloon-based high dose rate (HDR) brachytherapy planning. Methods: The maximal dose to skin and rib was objectively extracted from a dose volume histogram (DVH) of skin and rib volumes. A virtual skin volume was produced by expanding the skin surface in three dimensions (3D) external to the breast with a certain thickness in the planning computed tomography (CT) images. Therefore, the maximal dose to this volume occurs on the skin surface the same with a conventional manual selection method. The rib was also delineated in the planning CT images and its maximal dose was extracted from its DVH. The absolute (Abdiff=|D max Man -D max DVH |) and relative (Rediff[%]=100x(|D max Man -D max DVH |)/D max DVH ) maximal skin and rib dose differences between the manual selection method (D max Man ) and the objective method (D max DVH ) were measured for 50 balloon-based HDR (25 MammoSite and 25 Contura) patients. Results: The average±standard deviation of maximal dose difference was 1.67%±1.69% of the prescribed dose (PD). No statistical difference was observed between MammoSite and Contura patients for both Abdiff and Rediff[%] values. However, a statistically significant difference (p value max >90%) compared with lower dose range (D max <90%): 2.16%±1.93% vs 1.19%±1.25% with p value of 0.0049. However, the Rediff[%] analysis eliminated the inverse square factor and there was no statistically significant difference (p value=0.8931) between high and low dose ranges. Conclusions: The objective method using volumetric information of skin and rib can determine the planner-independent maximal dose compared with the manual selection method. However, the difference was <2% of PD, on average, if appropriate attention is paid to selecting a manual dose point in 3D planning CT images.

  13. Determination of uranium and thorium using gamma spectrometry: a pilot study

    Science.gov (United States)

    Olivares, D. M. M.; Koch, E. S.; Guevara, M. V. M.; Velasco, F. G.

    2018-03-01

    This paper presents the results of a pilot experiment aimed at standardizing procedures for the CPqCTR/UESC Gamma Spectrometry Laboratory (LEG) for the quantification of natural radioactive elements in solid environmental samples. The concentrations of 238U, 232Th and 40K in two sediment matrix belonging to the Caetité region were determined, by using the absolute method with uncertainties about 5%. The results were obtained using gamma spectrometry with a high-resolution p-type HPGe detector. As a closure, the absorbed dose, radium equivalent activity and the annual effective dose were calculated.

  14. Enantioselective semi-preparative HPLC separation of PCB metabolites and their absolute structures determined by electronic and vibrational circular dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Tuan, H.P.; Larsson, C.; Huehnerfuss, H. [Hamburg Univ. (Germany). Inst. fuer Organische Chemie; Hoffmann, F.; Froeba, M. [Giessen Univ. (Germany). Inst. fuer Anorganische und Analytische Chemie; Bergmann, Aa. [Stockholm Univ. (Sweden). Dept. of Environmental Chemistry

    2004-09-15

    The present paper represents a first result of an ongoing systematic study of atropisomeric methylsulfonyl, methylthionyl, hydroxy, and methoxy metabolites of environmentally most relevant PCBs. This involves semi-preparative enantioselective HPLC separation to obtain pure atropisomers from synthesized PCB metabolite standards, their configuration estimation using the electronic circular dichroism (UV-CD) method and the determination / confirmation of these absolute configurations applying the combined vibrational circular dichroism (VCD) / ab initio approach. The following substances have been investigated: 4-HO-, 4-MeO-, 4-MeS-, 4-MeSO2-, 3-MeS- and 3-MeSO{sub 2}-CB149.

  15. Using DNA origami nanostructures to determine absolute cross sections for UV photon-induced DNA strand breakage.

    Science.gov (United States)

    Vogel, Stefanie; Rackwitz, Jenny; Schürman, Robin; Prinz, Julia; Milosavljević, Aleksandar R; Réfrégiers, Matthieu; Giuliani, Alexandre; Bald, Ilko

    2015-11-19

    We have characterized ultraviolet (UV) photon-induced DNA strand break processes by determination of absolute cross sections for photoabsorption and for sequence-specific DNA single strand breakage induced by photons in an energy range from 6.50 to 8.94 eV. These represent the lowest-energy photons able to induce DNA strand breaks. Oligonucleotide targets are immobilized on a UV transparent substrate in controlled quantities through attachment to DNA origami templates. Photon-induced dissociation of single DNA strands is visualized and quantified using atomic force microscopy. The obtained quantum yields for strand breakage vary between 0.06 and 0.5, indicating highly efficient DNA strand breakage by UV photons, which is clearly dependent on the photon energy. Above the ionization threshold strand breakage becomes clearly the dominant form of DNA radiation damage, which is then also dependent on the nucleotide sequence.

  16. An automated LS(β)- NaI(Tl)(γ) coincidence system as absolute standard for radioactivity measurements.

    Science.gov (United States)

    Joseph, Leena; Das, A P; Ravindra, Anuradha; Kulkarni, D B; Kulkarni, M S

    2018-07-01

    4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of 60 Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions. Copyright © 2018. Published by Elsevier Ltd.

  17. Pharmacokinetics of marbofloxacin in pigs after intravenous and intramuscular administration of a single dose of 8 mg/kg: dose proportionality, influence of the age of the animals and urinary elimination.

    Science.gov (United States)

    Schneider, M; Paulin, A; Dron, F; Woehrlé, F

    2014-12-01

    The pharmacokinetics of marbofloxacin in pigs were evaluated as a function of dose and animal age following intravenous and intramuscular administration of a 16% solution (Forcyl(®) ). The absolute bioavailability of marbofloxacin as well as the dose proportionality was evaluated in 27-week-old fattening pigs. Blood PK and urinary excretion of marbofloxacin were evaluated after a single intramuscular dose of 8 mg/kg in 16-week-old male pigs. An additional group of 12-week-old weaned piglets was used for the evaluation of age-related kinetics. The plasma and urine concentration of marbofloxacin was determined using a HPLC method. Pharmacokinetic parameters were calculated using noncompartmental methods. After intravenous administration in 27-week-old fattening pigs, the total body clearance was 0.065 L/h·kg. After intramuscular administration to the same animals, the mean observed Cmax was 6.30 μg/mL, and the AUCINF was 115 μg·h/mL. The absolute bioavailability was 91.5%, and dose proportionality was shown within the dose range of 4-16 mg/kg. The renal clearance was about half of the value of the total clearance. The total systemic clearance values significantly decreased as a function of age, being 0.092 L/h·kg and 0.079 L/h·kg in pigs aged 12 and 16 weeks, respectively. © 2014 The Authors. Journal of Veterinary Pharmacology and Therapeutics Published by John Wiley & Sons Ltd.

  18. Is patient size important in dose determination and optimization in cardiology?

    International Nuclear Information System (INIS)

    Reay, J; Chapple, C L; Kotre, C J

    2003-01-01

    Patient dose determination and optimization have become more topical in recent years with the implementation of the Medical Exposures Directive into national legislation, the Ionising Radiation (Medical Exposure) Regulations. This legislation incorporates a requirement for new equipment to provide a means of displaying a measure of patient exposure and introduces the concept of diagnostic reference levels. It is normally assumed that patient dose is governed largely by patient size; however, in cardiology, where procedures are often very complex, the significance of patient size is less well understood. This study considers over 9000 cardiology procedures, undertaken throughout the north of England, and investigates the relationship between patient size and dose. It uses simple linear regression to calculate both correlation coefficients and significance levels for data sorted by both room and individual clinician for the four most common examinations, left ventrical and/or coronary angiography, single vessel stent insertion and single vessel angioplasty. This paper concludes that the correlation between patient size and dose is weak for the procedures considered. It also illustrates the use of an existing method for removing the effect of patient size from dose survey data. This allows typical doses and, therefore, reference levels to be defined for the purposes of dose optimization

  19. Determination of alpha-dose rates and chronostratigraphical study of travertine samples

    International Nuclear Information System (INIS)

    Oufni, L.; University Moulay Ismail, Errachidia; Misdaq, M.A.; Boudad, L.; Kabiri, L.

    2001-01-01

    Uranium and thorium contents in different layers of stratigraphical sedimentary deposits have been evaluated by using LR-115 type II and CR-39 solid state nuclear track detectors (SSNTD). A method has been developed for determining the alpha-dose rates of the sedimentary travertine samples. Using the U/Th dating method, we succeeded in age dating carbonated level sampled in the sedimentary deposits. Correlation between the stratigraphy, alpha-dose rates and age has been investigated. (author)

  20. Determination of the dose index in computerized tomography using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Azorin, J.C.; Calderon, A.; Azorin, J.

    2004-01-01

    In this work the obtained results of the determination of the dose index are presented in thorax studies in computed tomography and helical tomography carried out in Mexico using thermoluminescent dosemeters of LiF: Mg,Cu,P + Ptfe developed and manufactured in our country. The results showed that under similar conditions of irradiation and operation (pitch = 1), significant differences don't exist among the doses absorbed measures in the phantom due to the two types of used tomographs. (Author)

  1. Absolute measurement of the viscosity of classical and quantum fluids by rotating-cylinder viscometers

    International Nuclear Information System (INIS)

    Donnelly, R.J.; LaMar, M.M.

    1987-01-01

    We discuss the use of rotating-cylinder viscometers to determine absolute shear viscosities of classical fluids and of helium II in the context of past and current knowledge of the stability and flow of these fluids between concentric cylinders. We identify a problem in measuring the absolute viscosity when the inner cylinder is rotating and the outer cylinder is at rest. We conclude by discussing the design of viscometers for absolute viscosity measurements in helium I and helium II

  2. On the absorbed dose determination method in high energy photon beams

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Mitru, E.; Avadanei, C.

    2008-01-01

    The absorbed dose determination method in water, based on standards of air kerma or exposure in high energy photon beams generated by electron with energies in the range of 1 MeV to 50 MeV is presented herein. The method is based on IAEA-398, AAPM TG-51, DIN 6800-2, IAEA-381, IAEA-277 and NACP-80 recommendations. The dosimetry equipment is composed of UNIDOS T 10005 electrometer and different ionization chambers calibrated in air kerma method in a Co 60 beam. Starting from the general formalism showed in IAEA-381, the determination of absorbed dose in water, under reference conditions in high energy photon beams, is given. This method was adopted for the secondary standard dosimetry laboratory (SSDL) in NILPRP-Bucharest

  3. Single Dose Versus 3 Doses of Intramuscular Benzathine Penicillin for Early Syphilis in HIV: A Randomized Clinical Trial.

    Science.gov (United States)

    Andrade, Roberto; Rodriguez-Barradas, Maria C; Yasukawa, Kosuke; Villarreal, Erick; Ross, Michael; Serpa, Jose A

    2017-03-15

    Patients coinfected with syphilis and human immunodeficiency virus (HIV) may have a slower decrease in rapid plasma reagin (RPR) titers. Currently a single dose of 2.4 million units of intramuscular benzathine penicillin G (BPG) is recommended for the treatment of early syphilis. Some observational studies have suggested that this regimen may lead to high failure rates in coinfected patients. We conducted an open-label randomized clinical trial to compare the efficacy of single-dose and 3-dose regimens of BPG for the treatment of early syphilis in HIV-infected individuals. RPR titers were monitored every 3 months. Treatment success was defined as a decrease in RPR titers of ≥2 dilutions (4-fold) during a 12-month follow-up period. Sixty-four patients were included. In the intention-to-treat analysis, treatment success rates were 80% (28 of 35 subjects) and 93% (27 of 29 subjects) in the single-dose and 3-dose regimens, respectively (absolute difference, 13% [95% confidence interval {CI}, -5% to 30%; P = .17). In the per-protocol analysis, success rates were 93% (27 of 29) and 100% in the single-dose and 3-dose regimens, respectively (absolute difference, 7% [95% CI, -7% to 22%]; P = .49). CD4 T-cell count, RPR titer and syphilis stage did not affect treatment results. When compared with a single dose of BPG, a 3-dose regimen did not improve syphilis serological outcomes. Our results support the Centers for Disease Control and Prevention recommendation of a single dose of BPG in HIV-infected patients with early syphilis. NCT02611765. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  4. Concepts for dose determination in flat-detector CT

    International Nuclear Information System (INIS)

    Kyriakou, Yiannis; Deak, Paul; Langner, Oliver; Kalender, Willi A

    2008-01-01

    Flat-detector computed tomography (FD-CT) scanners provide large irradiation fields of typically 200 mm in the cranio-caudal direction. In consequence, dose assessment according to the current definition of the computed tomography dose index CTDI L=100mm , where L is the integration length, would demand larger ionization chambers and phantoms which do not appear practical. We investigated the usefulness of the CTDI concept and practical dosimetry approaches for FD-CT by measurements and Monte Carlo (MC) simulations. An MC simulation tool (ImpactMC, VAMP GmbH, Erlangen, Germany) was used to assess the dose characteristics and was calibrated with measurements of air kerma. For validation purposes measurements were performed on an Axiom Artis C-arm system (Siemens Medical Solutions, Forchheim, Germany) equipped with a flat detector of 40 cm x 30 cm. The dose was assessed for 70 kV and 125 kV in cylindrical PMMA phantoms of 160 mm and 320 mm diameter with a varying phantom length from 150 to 900 mm. MC simulation results were compared to the values obtained with a calibrated ionization chambers of 100 mm and 250 mm length and to thermoluminesence (TLD) dose profiles. The MCs simulations were used to calculate the efficiency of the CTDI L determination with respect to the desired CTDI ∞ . Both the MC simulation results and the dose distributions obtained by MC simulation were in very good agreement with the CTDI measurements and with the reference TLD profiles, respectively, to within 5%. Standard CTDI phantoms which have a z-extent of 150 mm underestimate the dose at the center by up to 55%, whereas a z-extent of ≥600 mm appears to be sufficient for FD-CT; the baseline value of the respective profile was within 1% to the reference baseline. As expected, the measurements with ionization chambers of 100 mm and 250 mm offer a limited accuracy, whereas an increased integration length of ≥600 mm appeared to be necessary to approximate CTDI ∞ in within 1%. MC

  5. Absolute instabilities of travelling wave solutions in a Keller-Segel model

    Science.gov (United States)

    Davis, P. N.; van Heijster, P.; Marangell, R.

    2017-11-01

    We investigate the spectral stability of travelling wave solutions in a Keller-Segel model of bacterial chemotaxis with a logarithmic chemosensitivity function and a constant, sublinear, and linear consumption rate. Linearising around the travelling wave solutions, we locate the essential and absolute spectrum of the associated linear operators and find that all travelling wave solutions have parts of the essential spectrum in the right half plane. However, we show that in the case of constant or sublinear consumption there exists a range of parameters such that the absolute spectrum is contained in the open left half plane and the essential spectrum can thus be weighted into the open left half plane. For the constant and sublinear consumption rate models we also determine critical parameter values for which the absolute spectrum crosses into the right half plane, indicating the onset of an absolute instability of the travelling wave solution. We observe that this crossing always occurs off of the real axis.

  6. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography

    International Nuclear Information System (INIS)

    Zhang, Jie; Patterson, Robert

    2010-01-01

    Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 ± 13 years, 78 ± 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC—end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Ω cm to 1583 Ω cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method

  7. Non-invasive determination of absolute lung resistivity in adults using electrical impedance tomography.

    Science.gov (United States)

    Zhang, Jie; Patterson, Robert

    2010-08-01

    Lung resistivity is a physiological parameter that describes the electrical characteristics of the lungs. Lung composition changes due to changes in the lung tissues, fluid and air volume. Various diseases that can cause a change in lung composition may be monitored by measuring lung resistivity. Currently, there is no accepted non-invasive method to measure lung resistivity. In this study, we presented a method and framework to non-invasively determine lung resistivity using electrical impedance tomography (EIT). By comparing actual measurements from subjects with data from a 3D human thorax model, an EIT image can be reconstructed to show a resistivity difference between the model and the subject. By adjusting the lung resistivity in the model, the resistivity difference in the lung regions can be reduced to near zero. This resistivity value then is the estimation of the lung resistivity of the subject. Using the proposed method, the lung resistivities of four normal adult males (43 +/- 13 years, 78 +/- 10 kg) in the supine position at air volumes starting at functional residual capacity (FRC--end expiration) and increasing in 0.5 l steps to 1.5 l were studied. The averaged lung resistivity changes 12.59%, from 1406 Omega cm to 1583 Omega cm, following the inspiration of 1.5 l air from FRC. The coefficients of variation (CV) of precision for the four subjects are less than 10%. The experiment was repeated five times at each air volume on a subject to test the reproducibility. The CVs are less than 3%. The results show that it is feasible to determine absolute lung resistivity using an EIT-based method.

  8. Determination of ionizing irradiation summary dose for animals of West Kazakstan

    International Nuclear Information System (INIS)

    Gal'tsev, V.E.; Nasirov, R.N.; Gal'tseva, E.V.; Lebedev, Ya.S.; Bubnov, N.N.

    1996-01-01

    By mean of tooth enamel EPR dosimetry the accumulated radiation doses received animals near Azgyr and Tajsojgan nuclear test sites (West Kazakstan) were determined . In the work camel's two teeth (Tajsojgan) and cow's two teeth (from Azgyr and Tajsojgan test sites - accordingly) were used. Registration of EPR spectrum has been carried out on production-type EPR-spectrometer ESR-300 of Bruker firm under temperature 77 K. SHF power level is 5 MW. Constant magnetic field's modulation frequency was equal to 100 k Hz and modulation amplitude was equal to 3,2 Gs. Received data allow to make conclusion that all tested animals have got summary dose exceeded significantly a natural background radiation dose (1-1,5 μGy/y. Comparison of irradiation dose accumulated in both the front and back tooth walls testifies about predominance of hard γ-rays in the spectrum. 4 refs., 2 figs

  9. Autoshaping as a psychophysical paradigm: Absolute visual sensitivity in the pigeon

    Science.gov (United States)

    Passe, Dennis H.

    1981-01-01

    A classical conditioning procedure (autoshaping) was used to determine absolute visual threshold in the pigeon. This method provides the basis for a standardized visual psychophysical paradigm. PMID:16812228

  10. Clinical use of carbon-loaded thermoluminescent dosimeters for skin dose determination

    International Nuclear Information System (INIS)

    Ostwald, Patricia M.; Kron, Tomas; Hamilton, Christopher S.; Denham, James W.

    1995-01-01

    Purpose: Carbon-loaded thermoluminescent dosimeters (TLDs) are designed for surface/skin dose measurements. Following 4 years in clinical use at the Mater Hospital, the accuracy and clinical usefulness of the carbon-loaded TLDs was assessed. Methods and Materials: Teflon-based carbon-loaded lithium fluoride (LiF) disks with a diameter of 13 mm were used in the present study. The TLDs were compared with ion chamber readings and TLD extrapolation to determine the effective depth of the TLD measurement. In vivo measurements were made on patients receiving open-field treatments to the chest, abdomen, and groin. Skin entry dose or entry and exit dose were assessed in comparison with doses estimated from phantom measurements. Results: The effective depth of measurement in a 6 MV therapeutic x-ray beam was found to be about 0.10 mm using TLD extrapolation as a comparison. Entrance surface dose measurements made on a solid water phantom agreed well with ion chamber and TLD extrapolation measurements, and black TLDs provide a more accurate exit dose than the other methods. Under clinical conditions, the black TLDs have an accuracy of ± 5% (± 2 SD). The dose predicted from black TLD readings correlate with observed skin reactions as assessed with reflectance spectroscopy. Conclusion: In vivo dosimetry with carbon-loaded TLDs proved to be a useful tool in assessing the dose delivered to the basal cell layer in the skin of patients undergoing radiotherapy

  11. DETERMINATION OF SUPERFICIAL ABSORBED DOSE FROM EXTERNAL EXPOSURE OF WEAKLY PENETRATING RADIATIONS

    Institute of Scientific and Technical Information of China (English)

    陈丽姝

    1994-01-01

    The methods of determining the superficial absorbed dose distributions in a water phantom by means of the experiments and available theories have been reported.The distributions of beta dose were measured by an extrapolation ionization chamber at definite depthes corresponding to some superficial organs and tissues such as the radiosensitive layer of the skin,cornea,sclera,anterior chamber and lens of eyeball.The ratios among superficial absorbed dose D(0.07) and average absorbed doses at the depthes 1,2,3,4,5 and 6mm are also obtained with Cross's methods.They can be used for confining the deterministic effects of some superficial tissues and organs such as the skin and the components of eyeball for weakly penetrating radiations.

  12. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    International Nuclear Information System (INIS)

    Moore, B; Brady, S; Kaufman, R; Mirro, A

    2014-01-01

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE

  13. MO-E-17A-04: Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Moore, B; Brady, S; Kaufman, R [St Jude Children' s Research Hospital, Memphis, TN (United States); Mirro, A [Washington University, St. Louis, MO (United States)

    2014-06-15

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) mean age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.

  14. A determination of the absolute radiant energy of a Robertson-Berger meter sunburn unit

    Science.gov (United States)

    DeLuisi, John J.; Harris, Joyce M.

    Data from a Robertson-Berger (RB) sunburn meter were compared with concurrent measurements obtained with an ultraviolet double monochromator (DM), and the absolute energy of one sunburn unit measured by the RB-meter was determined. It was found that at a solar zenith angle of 30° one sunburn unit (SU) is equivalent to 35 ± 4 mJ cm -2, and at a solar zenith angle of 69°, one SU is equivalent to 20 ± 2 mJ cm -2 (relative to a wavelength of 297 nm), where the rate of change is non-linear. The deviation is due to the different response functions of the RB-meter and the DM system used to simulate the response of human skin to the incident u.v. solar spectrum. The average growth rate of the deviation with increasing solar zenith angle was found to be 1.2% per degree between solar zenith angles 30 and 50° and 2.3% per degree between solar zenith angles 50 and 70°. The deviations of response with solar zenith angle were found to be consistent with reported RB-meter characteristics.

  15. Determination of Entrance Skin Doses and Organ Doses for Medical X Ray Examinations

    International Nuclear Information System (INIS)

    Tung, C.J.; Cheng, C.Y.; Chao, T.C.; Tsai, H.Y.

    1999-01-01

    A national survey of patient doses for diagnostic X ray radiographs is planned in Taiwan. Entrance skin doses and organ doses for all installed X ray machines will be investigated. A pilot study has been carried out for the national survey to develop a protocol for the dose assessment. Entrance skin doses and organ doses were measured by thermoluminescence dosemeters and calculated by Monte Carlo simulations for several X ray examinations. The conversion factor from free air entrance absorbed dose to entrance skin dose was derived. A formula for the computation of entrance skin doses from inputs of kV p , mA.s, source to skin distance, aluminium filtration, and generator rectifying was constructed. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom. All data will be passed to the Atomic Energy Council for developing a programme of national survey and regulatory controls for diagnostic X ray examinations. (author)

  16. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT plans already planned on treatment planning system (TPS for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA. All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA and dose for each plan was measured by 0.13 cc ion chamber. The percentage (% variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA plans were as 0.65 (Standard deviation (SD: 0.38 with confidence limit (CL 1.39, 1.16 (SD: 0.61 with CL 2.36 and 2.40 (SD: 0.86 with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  

  17. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    Science.gov (United States)

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies 80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Near threshold absolute TDCS: First results

    International Nuclear Information System (INIS)

    Roesel, T.; Schlemmer, P.; Roeder, J.; Frost, L.; Jung, K.; Ehrhardt, H.

    1992-01-01

    A new method, and first results for an impact energy 2 eV above the threshold of ionisation of helium, are presented for the measurement of absolute triple differential cross sections (TDCS) in a crossed beam experiment. The method is based upon measurement of beam/target overlap densities using known absolute total ionisation cross sections and of detection efficiencies using known absolute double differential cross sections (DDCS). For the present work the necessary absolute DDCS for 1 eV electrons had also to be measured. Results are presented for several different coplanar kinematics and are compared with recent DWBA calculations. (orig.)

  19. Absolute total cross sections for noble gas systems

    International Nuclear Information System (INIS)

    Kam, P. van der.

    1981-01-01

    This thesis deals with experiments on the elastic scattering of Ar, Kr and Xe, using the molecular beam technique. The aim of this work was the measurement of the absolute value of the total cross section and the behaviour of the total cross section, Q, as function of the relative velocity g of the scattering partners. The author gives an extensive analysis of the glory structure in the total cross section and parametrizes the experimental results using a semiclassical model function. This allows a detailed comparison of the phase and amplitude of the predicted and measured glory undulations. He indicates how the depth and position of the potential well should be changed in order to come to an optimum description of the glory structure. With this model function he has also been able to separate the glory and attractive contribution to Q, and using the results from the extrapolation measurements he has obtained absolute values for Qsub(a). From these absolute values he has calculated the parameter C 6 that determines the strength of the attractive region of the potential. In two of the four investigated gas combinations the obtained values lie outside the theoretical bounds. (Auth.)

  20. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron

    2014-01-01

    numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model...... is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken...

  1. Communication: Probing the absolute configuration of chiral molecules at aqueous interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lotze, Stephan, E-mail: lotze@amolf.nl; Versluis, Jan [FOM Institute for Atomic and Molecular Physics, Science Park 104, 1098 XG Amsterdam (Netherlands); Olijve, Luuk L. C.; Schijndel, Luuk van; Milroy, Lech G.; Voets, Ilja K. [Laboratory of Macromolecular and Organic Chemistry, Department of Chemical Engineering and Chemistry, and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Bakker, Huib J., E-mail: bakker@amolf.nl [FOM Institute AMOLF, Science Park 104, 1098 XG Amsterdam (Netherlands)

    2015-11-28

    We demonstrate that the enantiomers of chiral macromolecules at an aqueous interface can be distinguished with monolayer sensitivity using heterodyne-detected vibrational sum-frequency generation (VSFG). We perform VSFG spectroscopy with a polarization combination that selectively probes chiral molecular structures. By using frequencies far detuned from electronic resonances, we probe the chiral macromolecular structures with high surface specificity. The phase of the sum-frequency light generated by the chiral molecules is determined using heterodyne detection. With this approach, we can distinguish right-handed and left-handed helical peptides at a water-air interface. We thus show that heterodyne-detected VSFG is sensitive to the absolute configuration of complex, interfacial macromolecules and has the potential to determine the absolute configuration of enantiomers at interfaces.

  2. Determination of Effect of Low Dose Vs Moderate Dose of Clofibrate on the Decreasing in Serum Bilirubin Level in the Term Healthy Neonate

    OpenAIRE

    Mohammad Ashkan Moslehi; Narges Pishva

    2007-01-01

    Objective: This study was performed to determine the effect of low doses (25 mg/Kg) vs. moderate doses (50 mg/Kg) of clofibrate in treatment of non-hemolytic hyperbilirubin¬emia in healthy term neonates. Material & Methods: A clinical randomized controlled trial was performed in three groups of healthy term neonates. One group was treated with a single low dose of clofibrate (25 mg/Kg) while another group received a single moderate dose (50mg/kg) both orally plus phototherapy; the results wer...

  3. Absolute determination of the dominant amplitudes of the electroproduction of neutral pions at the momentum transfer of 0,630 GeV2

    International Nuclear Information System (INIS)

    Bantes, B.

    2003-10-01

    A complete Monte Carlo simulation for the neutral pion electroproduction experiment in the kinematics of the Δ(1232) that was carried out at the accelerator facility ELSA has been developed to correct the data concerning effects like detector resolution efficiencies, acceptances and radiation corrections. Results for the leading amplitudes are extracted at the four momentum transfer of 0.630 GeV 2 . Absolute cross sections are extracted using the well known elastic ep scattering to determine the luminosity. (orig.)

  4. Hyperglycemia in critical patients: Determinants of insulin dose choice

    Directory of Open Access Journals (Sweden)

    Aline Klitzke Paliosa

    Full Text Available Summary Objective: To identify factors that can determine the choice of intermittent subcutaneous regular insulin dose in critically ill patients with hyperglycemia. Method: Cross-sectional study in a general adult ICU with 26 beds, data collected between September and October 2014. The variables analyzed were: sex, age, previous diagnosis of diabetes mellitus, use of corticosteroids, use of lactulose, sepsis, fasting, enteral nutrition, use of dextrose 5% in water, NPH insulin prescription and blood glucose level. Patients with one or more episodes of hyperglycemia (blood glucose greater than 180 mg/dL were included as a convenience sample, not consecutively. Those with continuous insulin prescription were excluded from analysis. Results: We included 64 records of hyperglycemia observed in 22 patients who had at least one episode of hyperglycemia. The median administered subcutaneous regular human insulin was 6 IU and among the factors evaluated only blood glucose levels were associated with the choice of insulin dose administered. Conclusion: Clinical characteristics such as diet, medications and diagnosis of diabetes mellitus are clearly ignored in the decision-making regarding insulin dose to be administered for glucose control in critically ill patients with hyperglycemia.

  5. Determining absorbed dose of Ramsar people from natural radioactivity

    International Nuclear Information System (INIS)

    Ismaieli; Abdolreza

    1999-01-01

    Radiation exposure versus natural resources of environment is in external form. Especially, in some regions of the world radionuclides assembling in soils caused background of high radioactivity. Ramsar is one of these regions. The main purpose is to estimate gamma radiation exposure inside and outside of residential buildings in Ramsar and the suburbs and to present exposure map of Ramsar; also estimating internal exposure of radon gas and obtaining effective dose of Ramsar population. There for, SAPOS 90M gamma monitor and RSS-112 and Na I(Tl) scintillator were used. To determine the concentration of 226 Ra, 232 Th, 40 K in soil and building materials gamma spectrometer and Germanium detector were used. In addition to exposure rate of different sections of Ramsar and its suburbs, 200 residential houses with high exposure rate and more than 600 ones with normal exposure rate were determined. The results of measurement were respectively 11μRh -1 to 3 μRh -1 in indoor region and 11μRh -1 to 2μR -1 in indoor regions. Annual gamma exposure was 5.99+-18.01 mSv. Maximum of annual gamma exposure rate of this region is 131 mSv. The estimated radon dose, through previous measurement is approximated to 14.67+-39.14 mSv annually. normal exposure is respectively 8μRh -1 to 17μRh -1 in outdoor regions and 10μRh -1 to 130μRh -1 in indoor regions. Annual exposure rate of gamma radiation is 0.68+-0.01 mSv and estimated radon gas from indoor and outdoor exposure for effective dose is 2.34+ 0 .02 mSv

  6. Effects of 14-day oral low dose selenium nanoparticles and selenite in rat—as determined by metabolite pattern determination

    Directory of Open Access Journals (Sweden)

    Niels Hadrup

    2016-10-01

    Full Text Available Selenium (Se is an essential element with a small difference between physiological and toxic doses. To provide more effective and safe Se dosing regimens, as compared to dosing with ionic selenium, nanoparticle formulations have been developed. However, due to the nano-formulation, unexpected toxic effects may occur. We used metabolite pattern determination in urine to investigate biological and/or toxic effects in rats administered nanoparticles and for comparison included ionic selenium at an equimolar dose in the form of sodium selenite. Low doses of 10 and 100 fold the recommended human high level were employed to study the effects at borderline toxicity. Evaluations of all significantly changed putative metabolites, showed that Se nanoparticles and sodium selenite induced similar dose dependent changes of the metabolite pattern. Putative identified metabolites included increased decenedioic acid and hydroxydecanedioic acid for both Se formulations whereas dipeptides were only increased for selenite. These effects could reflect altered fatty acid and protein metabolism, respectively.

  7. Determination of burial dose in incompletely bleached fluvial samples using single grains of quartz

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, A.S.; Bøtter-Jensen, Lars

    2007-01-01

    We determine the burial dose in three known-age incompletely bleached fluvial samples using single grains of quartz. Estimation of burial dose in incompletely bleached samples requires that the characteristics of the well-bleached part of the distribution are known in order to distinguish between...... well-bleached and poorly bleached grains. It is especially important to investigate if the uncertainties assigned to individual estimates of dose adequately describe the observed variability in well-bleached dose distributions. We investigate this by quantifying the overdispersion in laboratory-bleached...

  8. Comparision between the IAEA's protocols (TRS-277 and TRS-398) for absorbed dose determination

    International Nuclear Information System (INIS)

    Bero, M.; Anjak, O.

    2007-12-01

    The aim of this study is to compare between two IAEA's Protocols [IAEA-TRS-277 (1987) and IAEA-TRS-398 (2000)] for Absorbed Dose Determination. Five types (5 Chamber) of commonly used cylindrical ionization chambers (Farmer type, 0.6 cc) were used to check the difference in absorbed dose to water determination for Co-60 beams under reference condition. TLD dosimeter was also used for inter-comparison with IAEA's SSDL. The mean values of the measured absorbed dose were found to be similar in both cases and the relative error D (TRS-398)/D (TRS-277) is found to be approximately less than 0.5% for all chambers used in this study.(authors)

  9. Determination of uranium and thorium using gamma spectrometry: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Olivares, D.M.M.; Koch, E.S.; Manso Guevara, M.V.; Garcia Velasco, F., E-mail: diango.mo87@gmail.com [Universidade Estadual de Santa Cruz (UNESC), Ilhéus, BA (Brazil)

    2017-07-01

    This paper presents the results of a pilot experiment aimed at standardizing procedures for the CPqCTR/UESC Gamma Spectrometry Laboratory (LEG) for the quantification of natural radioactive elements in solid environmental samples. The concentrations of {sup 238}U, {sup 232}Th and {sup 40}K in two sediment matrix belonging to the Caetité region were determined, by using the absolute method with uncertainties about 5%. The results were obtained using gamma spectrometry with a high-resolution p-type HPGe detector. As a closure, the absorbed dose, radium equivalent activity and the annual effective dose were calculated. (author)

  10. Determination of the dose of traffic in HDR brachytherapy with ALANINE/R PE technique

    International Nuclear Information System (INIS)

    Guzman Calcina, C. S.; Chen, F.; Almeida, A. de; Baffa, O.

    2001-01-01

    It determines, experimentally, the dose of traffic in brachytherapy for High Dose Rate (HDR), using for the first-time the Electronic Paramagnetic Resonance (EPR) technique with alanine detectors. The value obtained is the published next to obtained using lithium fluoride thermoluminescent dosimeters [es

  11. Relationship of bone marrow dose to eosinophilia following radiotherapy

    International Nuclear Information System (INIS)

    Murohashi, Ikuo; Gomi, Hiromichi; Nakano, Takashi; Morita, Shinroku; Arai, Tatsuo; Jinnai, Itsuro; Nara, Nobuo; Bessho, Masami; Hirashima, Kunitake.

    1986-01-01

    Absolute blood eosinophils were counted prior to and during radiotherapy in a total of 380 patients with carcinoma in the chest, pelvis, or abdomen. The patients were divided into 5 groups by types of cancer, and these groups differed in the irradiation sites or the sizes of radiation field. Accumulated bone marrow dose from the start of radiotherapy to the time when eosinophil count during radiotherapy reached its peak was simultaneously determined. In each group, maximum eosinophil count during radiotherapy was significantly increased compared with the value before radiotherapy. In all groups except one, the increase in eosinophil count following radiotherapy was directly proportional to the bone marrow dose. However, in the most heavily irradiated ovarian cancer group, the increase in eosinophil count was markedly lower. In contrast, neutrophils were reduced in numbers in all groups. These results suggest that bone marrow (red marrow) damage by irradiation results in eosinophilia, and that unimpaired hemopoiesis is also indispensable for such an eosinophil response. Accumulated bone marrow doses of 800 - 900 rad given during 4 weeks fractionated irradiation caused the most prominent eosinophilia. (author)

  12. Three-dimensional absorbed dose determinations by N.M.R. analysis of phantom-dosemeters

    International Nuclear Information System (INIS)

    Gambarini, G.; Birattari, C.; Fumagalli, M.L.; Vai, A.; Monti, D.; Salvadori, P.; Facchielli, L.; Sichirollo, A.E.

    1996-01-01

    Magnetic resonance imaging of a tissue-equivalent phantom is a promising technique for three-dimensional determination of absorbed dose from ionizing radiation. A reliable method of determining the spatial distribution of absorbed dose is indispensable for the planning of treatment in the presently developed radiotherapy techniques aimed at obtaining high energy selectively delivered to cancerous tissues, with low dose delivered to the surrounding healthy tissue. Aqueous gels infused with the Fricke dosemeter (i.e. with a ferrous sulphate solution), as proposed in 1984 by Gore et al., have shown interesting characteristics and, in spite of some drawbacks that cause a few limitations to their utilisation, they have shown the feasibility of three-dimensional dose determinations by nuclear magnetic resonance (NMR) imaging. Fricke-infused agarose gels with various compositions have been analysed, considering the requirements of the new radiotherapy techniques, in particular Boron Neutron Capture Therapy (B.N.C.T.) and proton therapy. Special attention was paid to obtain good tissue equivalence for every radiation type of interest. In particular, the tissue equivalence for thermal neutrons, which is a not simple problem, has also been satisfactorily attained. The responses of gel-dosemeters having the various chosen compositions have been analysed, by mean of NMR instrumentation. Spectrophotometric measurements have also been performed, to verify the consistence of the results. (author)

  13. A vibration correction method for free-fall absolute gravimeters

    Science.gov (United States)

    Qian, J.; Wang, G.; Wu, K.; Wang, L. J.

    2018-02-01

    An accurate determination of gravitational acceleration, usually approximated as 9.8 m s-2, has been playing an important role in the areas of metrology, geophysics, and geodetics. Absolute gravimetry has been experiencing rapid developments in recent years. Most absolute gravimeters today employ a free-fall method to measure gravitational acceleration. Noise from ground vibration has become one of the most serious factors limiting measurement precision. Compared to vibration isolators, the vibration correction method is a simple and feasible way to reduce the influence of ground vibrations. A modified vibration correction method is proposed and demonstrated. A two-dimensional golden section search algorithm is used to search for the best parameters of the hypothetical transfer function. Experiments using a T-1 absolute gravimeter are performed. It is verified that for an identical group of drop data, the modified method proposed in this paper can achieve better correction effects with much less computation than previous methods. Compared to vibration isolators, the correction method applies to more hostile environments and even dynamic platforms, and is expected to be used in a wider range of applications.

  14. Absorbed dose determination in kilovoltage X-ray synchrotron radiation using alanine dosimeters.

    Science.gov (United States)

    Butler, D J; Lye, J E; Wright, T E; Crossley, D; Sharpe, P H G; Stevenson, A W; Livingstone, J; Crosbie, J C

    2016-12-01

    Alanine dosimeters from the National Physical Laboratory (NPL) in the UK were irradiated using kilovoltage synchrotron radiation at the imaging and medical beam line (IMBL) at the Australian Synchrotron. A 20 × 20 mm 2 area was irradiated by scanning the phantom containing the alanine through the 1 mm × 20 mm beam at a constant velocity. The polychromatic beam had an average energy of 95 keV and nominal absorbed dose to water rate of 250 Gy/s. The absorbed dose to water in the solid water phantom was first determined using a PTW Model 31014 PinPoint ionization chamber traceable to a graphite calorimeter. The alanine was read out at NPL using correction factors determined for 60 Co, traceable to NPL standards, and a published energy correction was applied to correct for the effect of the synchrotron beam quality. The ratio of the doses determined by alanine at NPL and those determined at the synchrotron was 0.975 (standard uncertainty 0.042) when alanine energy correction factors published by Waldeland et al. (Waldeland E, Hole E O, Sagstuen E and Malinen E, Med. Phys. 2010, 37, 3569) were used, and 0.996 (standard uncertainty 0.031) when factors by Anton et al. (Anton M, Büermann L., Phys Med Biol. 2015 60 6113-29) were used. The results provide additional verification of the IMBL dosimetry.

  15. Calibration of ionization chambers and determination of the absorbed doses

    International Nuclear Information System (INIS)

    RANDRIANTSEHENO, H.F

    1996-01-01

    In order to further improve the accuracy of dosimetric measurements in radiation therapy, the IAEA and WHO supported the establishment of Secondary Standard Dosimetry Laboratory (SSDLs). These SSDLs bridge the gap between the primary measurement standards and the user of ionizing radiation by providing the latter with calibrations against the SSDLs' secondary standards and by giving technical advice and assistance. However, a properly calibrated dosimeter is just necessary first condition for the determination of the dose. It has been demonstrated that the success or failure of radiation treatment depends on the absorbed dose delivered to the tumour and that this should not vary by more than a few per cent from described values. [fr

  16. Comparative studies of the dose-response relationship of radiation-induced chromosomal aberrations in human lymphocytes induced by low radiation doses, using Feulgen orcein glacial acetic acid and FPG staining

    International Nuclear Information System (INIS)

    Wagner, R.

    1982-01-01

    Peripheral lymphocytes were exposed in vitro to 220 kV X-radiation, with doses of 0.05, 0.1, 0.2, 0.4, and 0.5 Gy, their culture and preparation was made under standardized conditions. The slides were stained using two different methods, namely FPG staining (fluorescence plus giemsa), and the conventional Feulgen orcein glacial acetic acid method. Compared to the conventional method, FPG staining achieved absolute yields of acentric fragments three times higher, and of dicentric chromosomes twice as high. A linear dose-response relationship in acentric fragments was found by the two staining methods alike, which agrees with the theory. Both staining methods revealed a linear-square dose-response relationship in dicentric chromosomes. Using FPG staining, preparing only M 1 cells for evaluation, the linear component was found to be dominant over the whole dose range applied. The conventional method, analysing M 1 and M 2 cells, revealed the square component to be the most important one. The dose-response relationships determined after FPG staining can be used for biological dosimetry. Calibration can be improved by increasing the number of cells analysed at doses [de

  17. Monte Carlo dose calculation improvements for low energy electron beams using eMC

    International Nuclear Information System (INIS)

    Fix, Michael K; Frei, Daniel; Volken, Werner; Born, Ernst J; Manser, Peter; Neuenschwander, Hans

    2010-01-01

    The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm 2 of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d max and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm 2 at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation

  18. Monte Carlo dose calculation improvements for low energy electron beams using eMC.

    Science.gov (United States)

    Fix, Michael K; Frei, Daniel; Volken, Werner; Neuenschwander, Hans; Born, Ernst J; Manser, Peter

    2010-08-21

    The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose

  19. Least Squares Problems with Absolute Quadratic Constraints

    Directory of Open Access Journals (Sweden)

    R. Schöne

    2012-01-01

    Full Text Available This paper analyzes linear least squares problems with absolute quadratic constraints. We develop a generalized theory following Bookstein's conic-fitting and Fitzgibbon's direct ellipse-specific fitting. Under simple preconditions, it can be shown that a minimum always exists and can be determined by a generalized eigenvalue problem. This problem is numerically reduced to an eigenvalue problem by multiplications of Givens' rotations. Finally, four applications of this approach are presented.

  20. Trends and the determination of effective doses for standard X-ray procedures

    International Nuclear Information System (INIS)

    Johnson, H.M.; Neduzak, C.; Gallet, J.; Sandeman, J.

    2001-01-01

    Trends in the entrance skin exposures (air kerma) for standard x-ray imaging procedures are reported for the Province of Manitoba, Canada. Average annual data per procedure using standard phantoms and standard ion chambers have been recorded since 1981. For example, chest air kerma (backscatter included) has decreased from 0.14 to 0.09 mGy. Confounding factors may negate the gains unless facility quality control programs are maintained. The data were obtained for a quality assurance and regulatory compliance program. Quoting such data for risk evaluation purposes lacks rigor hence a compartment model for organ apportioning, using organ absorbed doses and weighting factors, has been applied to determine effective dose per procedure. The effective doses for the standard procedures are presented, including the value of 0.027 mSv (1999) calculated for the effective dose in PA chest imaging. (author)

  1. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Santos, Emilie M.M.; Yoo, Albert J.; Beenen, Ludo F.; Majoie, Charles B.; Berkhemer, Olvert A.; Blanken, Mark D. den; Wismans, Carrie; Niessen, Wiro J.; Marquering, Henk A.

    2016-01-01

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  2. Observer variability of absolute and relative thrombus density measurements in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Emilie M.M. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Department of Radiology, AMC, Amsterdam (Netherlands); Yoo, Albert J. [Texas Stroke Institute, Plano, TX (United States); Beenen, Ludo F.; Majoie, Charles B. [Department of Radiology, AMC, Amsterdam (Netherlands); Berkhemer, Olvert A. [Department of Radiology, AMC, Amsterdam (Netherlands); Department of Neurology, Erasmus MC, Rotterdam (Netherlands); Blanken, Mark D. den; Wismans, Carrie [AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Niessen, Wiro J. [Erasmus MC - University Medical Center Rotterdam, Department of Radiology, P.O. Box 2040, Rotterdam (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Delft (Netherlands); Marquering, Henk A. [Department of Radiology, AMC, Amsterdam (Netherlands); AMC, Department of Biomedical Engineering and Physics, Amsterdam (Netherlands); Collaboration: on behalf of the MR CLEAN investigators

    2016-02-15

    Thrombus density may be a predictor for acute ischemic stroke treatment success. However, only limited data on observer variability for thrombus density measurements exist. This study assesses the variability and bias of four common thrombus density measurement methods by expert and non-expert observers. For 132 consecutive patients with acute ischemic stroke, three experts and two trained observers determined thrombus density by placing three standardized regions of interest (ROIs) in the thrombus and corresponding contralateral arterial segment. Subsequently, absolute and relative thrombus densities were determined using either one or three ROIs. Intraclass correlation coefficient (ICC) was determined, and Bland-Altman analysis was performed to evaluate interobserver and intermethod agreement. Accuracy of the trained observer was evaluated with a reference expert observer using the same statistical analysis. The highest interobserver agreement was obtained for absolute thrombus measurements using three ROIs (ICCs ranging from 0.54 to 0.91). In general, interobserver agreement was lower for relative measurements, and for using one instead of three ROIs. Interobserver agreement of trained non-experts and experts was similar. Accuracy of the trained observer measurements was comparable to the expert interobserver agreement and was better for absolute measurements and with three ROIs. The agreement between the one ROI and three ROI methods was good. Absolute thrombus density measurement has superior interobserver agreement compared to relative density measurement. Interobserver variation is smaller when multiple ROIs are used. Trained non-expert observers can accurately and reproducibly assess absolute thrombus densities using three ROIs. (orig.)

  3. Numerical simulation of a TLD pulsed laser-heating scheme for determination of shallow dose and deep dose in low-LET radiation fields

    International Nuclear Information System (INIS)

    Kearfott, K.J.; Han, S.; Wagner, E.C.; Samei, E.; Wang, C.-K.C.

    2000-01-01

    A new method is described to determine the depth-dose distribution in low-LET radiation fields using a thick thermoluminescent dosimeter (TLD) with a pulsed laser-heating scheme to obtain TL glow output. The computational simulation entails heat conduction and glow curve production processes. An iterative algorithm is used to obtain the dose distribution in the detector. The simulation results indicate that the method can predict the shallow and deep dose in various radiation fields with relative errors less than 20%

  4. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    Science.gov (United States)

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  5. Absolute configurations of zingiberenols isolated from ginger (Zingiber officinale) rhizomes

    Science.gov (United States)

    The sesquiterpene alcohol zingiberenol, or 1,10-bisaboladien-3-ol, was isolated some time ago from ginger, Zingiber officinale, rhizomes, but its absolute configuration had not been determined. With three chiral centers present in the molecule, zingiberenol can exist in eight stereoisomeric forms. ...

  6. Projective absoluteness for Sacks forcing

    NARCIS (Netherlands)

    Ikegami, D.

    2009-01-01

    We show that Sigma(1)(3)-absoluteness for Sacks forcing is equivalent to the nonexistence of a Delta(1)(2) Bernstein set. We also show that Sacks forcing is the weakest forcing notion among all of the preorders that add a new real with respect to Sigma(1)(3) forcing absoluteness.

  7. Forecasting Error Calculation with Mean Absolute Deviation and Mean Absolute Percentage Error

    Science.gov (United States)

    Khair, Ummul; Fahmi, Hasanul; Hakim, Sarudin Al; Rahim, Robbi

    2017-12-01

    Prediction using a forecasting method is one of the most important things for an organization, the selection of appropriate forecasting methods is also important but the percentage error of a method is more important in order for decision makers to adopt the right culture, the use of the Mean Absolute Deviation and Mean Absolute Percentage Error to calculate the percentage of mistakes in the least square method resulted in a percentage of 9.77% and it was decided that the least square method be worked for time series and trend data.

  8. Absolute Hydration Free Energy of Proton from First Principles Electronic Structure Calculations

    International Nuclear Information System (INIS)

    Zhan, Chang-Guo; Dixon, David A.

    2001-01-01

    The absolute hydration free energy of the proton, DGhyd298(H+), is one of the fundamental quantities for the thermodynamics of aqueous systems. Its exact value remains unknown despite extensive experimental and computational efforts. We report a first-principles determination of DGhyd298(H+) by using the latest developments in electronic structure theory and massively parallel computers. DGhyd298(H+) is accurately predicted to be -262.4 kcal/mol based on high-level, first-principles solvation-included electronic structure calculations. The absolute hydration free energies of other cations can be obtained by using appropriate available thermodynamic data in combination with this value. The high accuracy of the predicted absolute hydration free energy of proton is confirmed by applying the same protocol to predict DGhyd298(Li+)

  9. Determination of Doses for X-Ray Examinations of Paranasal Sinuses of Children

    International Nuclear Information System (INIS)

    Milkovic, D.; Miljanic, S.; Knezevic, Z.; Ranogajec-Komor, M.; Beck, N; Zagar, I.

    2013-01-01

    The knowledge of the absorbed doses during X-ray examination is very important, especially in paediatric radiology in order to improve radiation protection. In childhood, the paranasal sinuses diseases are very frequent and the development of sinuses has some specialities which has to be taken into consideration in X-ray diagnostics. The aim of this work was the determination of the relative doses on the thyroid gland and eyes, in respect to the entrance dose on the anthropomorphic child phantom (CIRS). The entrance doses on the phantom to the entrance dose on patients of similar age. Simultaneously the influence of human working method was studied, i.e. the performance of the radiological technicians. The age of the patients varied from 7 to 15 years, the child phantom was equivalent to 10 years age. A protective lead apron on the necks of both children and phantom was used. Doses were measured with radiophotoluminescence (RPL) and thermoluminescence (TL) dosemeters. The mean doses on the thyroid and the eyes measured in the phantom after 10 expositions were 0.20 ± 0.05 mSv, and 0.32 ± 0.02 mSv, respectively. Relative doses were calculated in relation to entrance dose of 9.96 mSv for 10 exposures, and the results were 0.02 and 0.03 for the thyroid gland and the eyes, respectively. The dosimetry results on 45 patients showed that there was a good correlation between measured doses and the body mass index (BMI). The mean entrance dose measured on the 45 patients was 0.97 ± 0.08 mSv.(author)

  10. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    International Nuclear Information System (INIS)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R.; Gallego, E.; Lorente, A.

    2012-10-01

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,θ) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  11. Determination of fluence-to-dose conversion coefficients by means of artificial neural networks

    Energy Technology Data Exchange (ETDEWEB)

    Soto B, T. G.; Rivera P, E.; De Leon M, H. A.; Hernandez D, V. M.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Gallego, E.; Lorente, A., E-mail: tzinnia.soto@gmail.com [Universidad Politecnica de Madrid, Departamento de Ingenieria Nuclear, Jose Gutierrez Abascal No. 2, 28006 Madrid (Spain)

    2012-10-15

    In this paper is presented an Artificial Neural Network (Ann) that has been designed, trained and validated to determinate the effective dose e, ambient dose equivalent h(10) and personal dose equivalent hp(10,{theta}) fluence-to-dose conversion coefficients at different positions, having as only input data 7 count rates obtained with a Bonner Sphere Spectrometer (Bss) system. A set of 211 neutron spectra and the fluence-to-dose conversion coefficients published by the International Atomic Energy Agency were used to train and validate the Ann. This set was divided into 2 subsets, one of 181 elements to train the Ann and the remaining 30 to validate it. The Ann was trained using Bss count rates as input data and the fluence-to-dose conversion coefficients as output data. The network was validated and tested with the set of 30 elements that were not used during the training process. Good results were obtained proving that Ann are a good choice for calculating the fluence-to-dose conversion coefficients having as only data the count rates obtained with a Bss. (Author)

  12. The irradiation tolerance dose of the proximal vagina

    International Nuclear Information System (INIS)

    Au, Samuel P.; Grigsby, Perry W.

    2003-01-01

    Purpose: The purpose of this investigation was to determine the irradiation tolerance level and complication rates of the proximal vagina to combined external irradiation and low dose rate (LDR) brachytherapy. Also, the mucosal tolerance for fractionated high dose rate (HDR) brachytherapy is further projected based on the biological equivalent dose (BED) of LDR for an acceptable complication rate. Materials and methods: Two hundred seventy-four patients with stages I-IV cervical carcinoma treated with irradiation therapy alone from 1987 to 1997 were retrospectively reviewed for radiation-associated late sequelae of the proximal vagina. All patients received LDR brachytherapy and 95% also received external pelvic irradiation. Follow-up ranged from 15 to 126 months (median, 43 months). The proximal vagina mucosa dose from a single ovoid (single source) or from both ovoids plus the tandem (all sources), together with the external irradiation dose, were used to derive the probability of a complication using the maximum likelihood logistic regression technique. The BED based on the linear-quadratic model was used to compute the corresponding tolerance levels for LDR or HDR brachytherapy. Results: Grades 1 and 2 complications occurred in 10.6% of patients and Grade 3 complications occurred in 3.6%. There were no Grade 4 complications. Complications occurred from 3 to 71 months (median, 7 months) after completion of irradiation, with over 60% occurring in the first year. By logistic regression analysis, both the mucosal dose from a single ovoid or that from all sources, combined with the external irradiation dose, demonstrate a statistically significant fit to the dose response complication curves (both with P=0.016). The single source dose was highly correlated with the all source dose with a cross-correlation coefficient 0.93. The all source dose was approximately 1.4 times the single source dose. Over the LDR brachytherapy dose rate range, the complication rate was

  13. Dose verification with different ion chambers for SRT/SBRT plans

    Science.gov (United States)

    Durmus, I. F.; Tas, B.; Okumus, A.; Uzel, O. E.

    2017-02-01

    Verification of patient plan is very important in stereotactic treatments. VMAT plans were prepared with 6MV-FFF or 10MV-FFF energies for 25 intracranial and extracranial stereotactic patients. Absolute dose was measured for dose verification in each plans. Iba® CC01, Iba® CC04, Iba® CC13 ion chambers placed at a depth of 5cm in solid phantom (RW3). Also we scanned this phantom with ion chambers by Siemens® Biograph mCT. QA plans were prepared by transferring twenty five patient plans to phantom assemblies for three ion chambers. All plans were performed separately for three ion chambers at Elekta® Versa HD linear accelerator. Statistical analysis of results were made by Wilcoxon signed-rank test. Difference between dose values were determined %1.84±3.4 (p: 0.001) with Iba CC13 ion chamber, %1.80±3.4 (p: 0.002) with Iba CC04 ion chamber and %0.29±4.6 (p: 0.667) with Iba CC01 ion chamber. In stereotactic treatments, dosimetric uncertainty increases in small areas. We determined more accurate results with small sized detectors. Difference between TPS calculations and all measurements were founded lower than %2.

  14. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    Science.gov (United States)

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  15. Determination of dose received by bladder and rectum in external cervical irradiation

    International Nuclear Information System (INIS)

    Omer, Mohamed Ahmed Ali

    2001-12-01

    The cervical carcinoma is the common type of malignant tumor among sudanese females during the last years. The conventional external irradiation therapy is the common model of treatment for cervical carcinoma in (RICK). The irradiation of such cases implemented via four fields (box technique), two anterior and posterior and two lateral opposed fields, as central dose calculation, giving a dose of 5000 c Gy fractionated into 25 to 30 fractions. The parameter of the fields lie at the promontory of the sacral cephalic and at the obturators foramen caudally and laterally at the bony pelvic by one centimeter. The aim of the research is to determine the dose received by the rectum and bladder (critical organs), out of central dose calculation versus off axis dose calculation to (Day's method). The data obtained by using simulator and radiation oncological computerized system (Rocs). The results are analyzed by using statistical processing for social science program (SPSS) that shows the mean dose received by the bladder is 3821 cGy, due to central dose calculation that accompanied by an un-optimum encompassment of treatment line and 4210.6 c Gy. due to Off Axis Dose calculation dose 3324.4 c Gy and 3712.1 c Gy due to central dose calculation. The increment of dose received by the rectum and the bladder is due to utilizing of wider width of the filed size for lateral irradiation. To score the aim of International Atomic Energy Agency (IAEA) and (ALARA) principle A s Low As As Reasonable Available , we have to use the simulator to obtain the anatomical structures on the contour, or will be better to use CT. Scan for calculation of dose at the side of interest. (Author)

  16. A non-invasive diffuse reflectance calibration-free method for absolute determination of exogenous biochemicals concentration in biological tissues

    Science.gov (United States)

    Lappa, Alexander V.; Kulikovskiy, Artem N.; Busarov, Oleg G.

    2014-03-01

    The paper presents a new method for distant non-destructive determination of concentration of light absorbing admixtures in turbid media. In particular, it is intended for non-invasive in vivo control of accumulation in patient tissues of various biochemicals introduced to the patients for chemotherapy, photodynamic therapy or diagnostics. It is require that the admixture absorption spectrum should have a clearly marked peak in the wavelength region where the pure medium one varies regularly. Fluorescence of admixtures is not required. The method uses the local diffuse reflectance spectroscopy with optical fiber probe including one emitting and two reading There are several features in the method: the value to be determined is absolute concentration of admixtures; the method needs no calibration measurements on phantoms; it needs no reference measurements on sample with zero admixture concentration; it uses a two parametric kinetic light propagation model and original algorithms to resolve direct and inverse tasks of radiation transport theory. Experimental testing passed with tissue equivalent phantoms and different admixtures, including a chlorine photosensitizer, showed accuracy under 10% in all cases.

  17. Structure and Absolute Configuration of Nyasol and Hinokiresinol via Synthesis and Vibrational Circular Dichroism Spectroscopy

    DEFF Research Database (Denmark)

    Lassen, Peter Rygaard

    2005-01-01

    The absolute configuration of the norlignan (+)-nyasol was determined to be S by comparison of the experimental vibrational circular dichroism data with first-principle calculations taking into account the eight lowest energy conformations. The established absolute configuration of (+)-nyasol...... enables establishment of the absolute configuration of (-)-hinokiresinol, which is concluded to be S. A total synthesis and resolution of hinokiresinol has been performed to resolve the conflicting reports of the coupling constant of the vinylic protons of the disubstituted double bond in this molecule...

  18. Absolute photoionization cross-section of the propargyl radical

    Energy Technology Data Exchange (ETDEWEB)

    Savee, John D.; Welz, Oliver; Taatjes, Craig A.; Osborn, David L. [Sandia National Laboratories, Combustion Research Facility, Livermore, California 94551 (United States); Soorkia, Satchin [Institut des Sciences Moleculaires d' Orsay, Universite Paris-Sud 11, Orsay (France); Selby, Talitha M. [Department of Chemistry, University of Wisconsin, Washington County Campus, West Bend, Wisconsin 53095 (United States)

    2012-04-07

    Using synchrotron-generated vacuum-ultraviolet radiation and multiplexed time-resolved photoionization mass spectrometry we have measured the absolute photoionization cross-section for the propargyl (C{sub 3}H{sub 3}) radical, {sigma}{sub propargyl}{sup ion}(E), relative to the known absolute cross-section of the methyl (CH{sub 3}) radical. We generated a stoichiometric 1:1 ratio of C{sub 3}H{sub 3} : CH{sub 3} from 193 nm photolysis of two different C{sub 4}H{sub 6} isomers (1-butyne and 1,3-butadiene). Photolysis of 1-butyne yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(26.1{+-}4.2) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(23.4{+-}3.2) Mb, whereas photolysis of 1,3-butadiene yielded values of {sigma}{sub propargyl}{sup ion}(10.213 eV)=(23.6{+-}3.6) Mb and {sigma}{sub propargyl}{sup ion}(10.413 eV)=(25.1{+-}3.5) Mb. These measurements place our relative photoionization cross-section spectrum for propargyl on an absolute scale between 8.6 and 10.5 eV. The cross-section derived from our results is approximately a factor of three larger than previous determinations.

  19. Quality audit for dose determination in the field of radiotherapy using TLD

    International Nuclear Information System (INIS)

    Kharita, M. H.; Anjak, O.

    2010-08-01

    Quality audit is one of the important procedures in radiotherapy centers in order to verify the accuracy of the delivered radiation doses. The aim of this work is to establish a procedure for dose audit using TL dosimeters and to apply this procedure in radiotherapy centers. TL Dosimeters were distributed to several radiotherapy centers in Syria and Lebanon (4 with Co-60 and 14 with high energy photon beam radiotherapy units). They were exposed to 2 Gy in order to make an intercomparison study of the absorbed dose in water determined under reference conditions. The results show that only two beams were outside the accepted range, which is ±3.5%. and the were within the accepted range. External Quality audit is one of the important procedures in field of radiotherapy dosimeter in order to verify the accuracy of the radiation doses delivered to patients. (Author)

  20. Commercial sugar, an alternative dosemeter for the dose determination in radiological emergency conditions

    International Nuclear Information System (INIS)

    Urena N, F.; Galindo, S.

    1997-01-01

    It was carried out the dosimetric evaluation of commercial sugar, with the purpose to determine the feasibility to be able to use this type of substance as a dosimetric material in cases to present some radiological emergency cases. The studied parameters using the Electron Paramagnetic Resonance (EPR) technique were: pre-doses signal or depth signal, dose-response stability, reproducibility, reliability and signal clearing decreasing. (Author)

  1. A method, using ICRP 26 weighting factors, to determine effective dose equivalent due to nonuniform external exposures

    International Nuclear Information System (INIS)

    Dyer, S.G.

    1993-01-01

    Westinghouse Savannah River Company (WSRC) has recently implemented a methodology and supporting procedures to calculate effective dose equivalent for external exposures. The calculations are based on ICRP 26 methodology and are used to evaluate exposures when multibadging is used. The methodology is based upon the concept of open-quotes whole bodyclose quotes compartmentalization (i.e., the whole body is separated into seven specific regions of radiological concern and weighted accordingly). The highest dose measured in each compartment is used to determine the weighted dose to that compartment. Benefits of determining effective dose equivalent are compliance with DOE Orders, more accurate dose assessments, and the opportunity for improved worker protection through new ALARA opportunities

  2. Direct Determination of Absolute Configuration of Methyl-Substituted Phenyloxiranes: A Combined Experimental and Theoretical Approach

    DEFF Research Database (Denmark)

    Fristrup, Peter; Lassen, Peter Rygaard; Johannessen, Christian

    2006-01-01

    obtained from quantum mechanical calculations (density functional theory with the B3LYP hybrid exchange correlation functional with 6-31++G**, aug-cc-pVDZ, or aug-cc-pVTZ basis set) and related to the physical structure of the compounds. The absolute configuration could be established directly in each case...

  3. Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

    International Nuclear Information System (INIS)

    Li, Heng; Zhu, X. Ronald; Zhang, Xiaodong

    2015-01-01

    Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

  4. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  5. Standardization of a method to calculate absolute renal uptake of 99m Tc-DMSA in children

    International Nuclear Information System (INIS)

    Ono, Carla Rachel; Sapienza, Marcelo Tatit; Watanabe, Tomoco; Costa, Paulo Luiz Aguirre; Okamoto, Miriam Roseli Yoshie; Garcez, Alexandre Teles; Buchpiguel, Carlos Alberto; Machado, Beatriz Marcondes; Machado, Marcia Melo Campos; Liberato Junior, Waldyr de Paula

    2006-01-01

    Objective:To standardize a method and determine normal values for absolute renal uptake of 99m Tc-DMSA in children with normal creatinine clearance. Materials and methods: Twenty-two children (between 7 months and 10 years of age; mean 4.5 years) without clinical evidence of renal disease were studied using 99m Tc-DMSA scintigraphy. Eighteen had normal renal ultrasonography, micturating urethrocystography, creatinine clearance and visual interpretation of the scintigraphy with 99m Tc-DMSA. Four children were excluded, one with incomplete creatinine clearance and three due to reduction in the creatinine clearance. Absolute renal uptake of 99m Tc-DMSA (DMSA-Abs) was expressed as the fraction of the administered dose retained by each kidney six hours after administration of the radiopharmaceutical. Results: DMSA-Abs was 21.8 +- 3.2% for the right kidney and 23.1 +-3.3% for the left kidney. There was no correlation between renal uptake and the age groups studied, although there was a tendency to an increase in the creatinine clearance with age. Conclusion: Normal values of DMSA-Abs can be used as an additional parameter for the initial diagnostic evaluation and during follow-up of renal diseases, mainly when bilateral impairment of renal function is suspected or in a patient with a single functioning kidney (in which renal differential function is of limited value). (author)

  6. Use of thermoluminescence dosimetry for evaluation of internal beta dose-rate in archaeological dating

    Energy Technology Data Exchange (ETDEWEB)

    Bailiff, I K; Aitken, M J [Oxford Univ. (UK). Research Lab. for Archaeology

    1980-07-01

    An experimental technique is described for the absolute determination of beta dose-rate in pottery. The calibrated system utilizes thermoluminescent dosimeters (natural calcium fluoride) which are located external to the pottery sample. These measurements give an evaluation of the dose-rate at the centre of the pottery that is effectively independent of the relative importance of the thorium, uranium and potassium content (typically 12 ppm Th, 3 ppm U and 1% K/sub 2/O in pottery). This has been checked using analysed uranium, thorium and potassium materials. A dose-rate evaluation may be made after 10-14 d with an accuracy of +-5%, where the dose-rate to the dosimeter is of the order of 0.3 mrad d/sup -1/. Although the background dose-rate due to cosmic radiation and that arising from radioactive impurities in the calcium fluoride is significant (one third), measurements have shown that it may be accurately established. The technique described is to be preferred to other systems used in pottery dating because of its independence of relative radioisotope concentration.

  7. Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Jennifer L., E-mail: peterson.jennifer2@mayo.edu [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States); Buskirk, Steven J. [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States); Heckman, Michael G.; Diehl, Nancy N. [Section of Biostatistics, Mayo Clinic Florida, Jacksonville, FL (United States); Bernard, Johnny R. [Section of Biostatistics, Mayo Clinic Florida, Jacksonville, FL (United States); Department of Radiation Oncology, Southern Ohio Medical Center, Portsmouth, OH (United States); Tzou, Katherine S.; Casale, Henry E.; Bellefontaine, Louis P.; Serago, Christopher; Kim, Siyong; Vallow, Laura A.; Daugherty, Larry C.; Ko, Stephen J. [Department of Radiation Oncology, Mayo Clinic Florida, Jacksonville, FL (United States)

    2014-04-01

    Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm{sup 3} of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications.

  8. Image-guided intensity-modulated radiotherapy for prostate cancer: Dose constraints for the anterior rectal wall to minimize rectal toxicity

    International Nuclear Information System (INIS)

    Peterson, Jennifer L.; Buskirk, Steven J.; Heckman, Michael G.; Diehl, Nancy N.; Bernard, Johnny R.; Tzou, Katherine S.; Casale, Henry E.; Bellefontaine, Louis P.; Serago, Christopher; Kim, Siyong; Vallow, Laura A.; Daugherty, Larry C.; Ko, Stephen J.

    2014-01-01

    Rectal adverse events (AEs) are a major concern with definitive radiotherapy (RT) treatment for prostate cancer. The anterior rectal wall is at the greatest risk of injury as it lies closest to the target volume and receives the highest dose of RT. This study evaluated the absolute volume of anterior rectal wall receiving a high dose to identify potential ideal dose constraints that can minimize rectal AEs. A total of 111 consecutive patients with Stage T1c to T3a N0 M0 prostate cancer who underwent image-guided intensity-modulated RT at our institution were included. AEs were graded according to the Common Terminology Criteria for Adverse Events, version 4.0. The volume of anterior rectal wall receiving 5 to 80 Gy in 2.5-Gy increments was determined. Multivariable Cox regression models were used to identify cut points in these volumes that led to an increased risk of early and late rectal AEs. Early AEs occurred in most patients (88%); however, relatively few of them (13%) were grade ≥2. At 5 years, the cumulative incidence of late rectal AEs was 37%, with only 5% being grade ≥2. For almost all RT doses, we identified a threshold of irradiated absolute volume of anterior rectal wall above which there was at least a trend toward a significantly higher rate of AEs. Most strikingly, patients with more than 1.29, 0.73, or 0.45 cm 3 of anterior rectal wall exposed to radiation doses of 67.5, 70, or 72.5 Gy, respectively, had a significantly increased risk of late AEs (relative risks [RR]: 2.18 to 2.72; p ≤ 0.041) and of grade ≥ 2 early AEs (RR: 6.36 to 6.48; p = 0.004). Our study provides evidence that definitive image-guided intensity-modulated radiotherapy (IG-IMRT) for prostate cancer is well tolerated and also identifies dose thresholds for the absolute volume of anterior rectal wall above which patients are at greater risk of early and late complications

  9. Absolute total electronically elastic differential e--H2 scattering cross-section measurements from 1 to 19 eV

    International Nuclear Information System (INIS)

    Furst, J.; Mahgerefteh, M.; Golden, D.E.

    1984-01-01

    Absolute e - -H 2 total electronically elastic differential scattering cross sections have been determined from relative scattered-electron angular distribution measurements in the energy range from 1 to 19 eV by comparison to absolute e - -He elastic differential scattering cross sections measured in the same apparatus. Integrated total cross sections have been determined as well. Absolute differences as large as 50% between the present results and some previous results have been found, although the agreement as to shape is quite good in many cases. The present results are generally in excellent agreement with recent full rovibrational laboratory-frame close-coupling calculations

  10. Experimental Determination of the Neutron Radiation-Dose Distribution in the Human Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Stipcic, Neda [Institute Rudjer Bogkovic, Zagreb, Yugoslavia (Serbia)

    1967-01-15

    The quality of the radiation delivering the radiation dose to the human phantom is quite different from that of the incident neutron beam. This paper describes the experimental investigation of the variation of neutron dose related to the variation of neutron fluence with depth in the human phantom. The distribution of neutron radiation was determined in the human phantom - a cube of paraffin wax 25 cm x 25 cm x 50 cm with a density of 0.92 cm{sup -3}. Po-Be and Ra-Be point sources were used as neutron sources. Neutron fluences were measured using different types of detector: scintillation detector, BF{sub 3} counter, and nuclear-track emulsions. Since the fluence measurements with these three types of detectors were carried out under the same experimental conditions, it was possible to separate and analyse each part of the radiation dose in the paraffin. From the investigations, the distribution of the total radiation dose was obtained as a function of the paraffin depth. The maximum value of this dose distribution is constant with respect to the distance between the source and the paraffin phantom. From the results obtained, some conclusions may be drawn concerning the amount of absorbed radiation dose in the human phantom. (author)

  11. Variance computations for functional of absolute risk estimates.

    Science.gov (United States)

    Pfeiffer, R M; Petracci, E

    2011-07-01

    We present a simple influence function based approach to compute the variances of estimates of absolute risk and functions of absolute risk. We apply this approach to criteria that assess the impact of changes in the risk factor distribution on absolute risk for an individual and at the population level. As an illustration we use an absolute risk prediction model for breast cancer that includes modifiable risk factors in addition to standard breast cancer risk factors. Influence function based variance estimates for absolute risk and the criteria are compared to bootstrap variance estimates.

  12. Optimized computational method for determining the beta dose distribution using a multiple-element thermoluminescent dosimeter system

    International Nuclear Information System (INIS)

    Shen, L.; Levine, S.H.; Catchen, G.L.

    1987-01-01

    This paper describes an optimization method for determining the beta dose distribution in tissue, and it describes the associated testing and verification. The method uses electron transport theory and optimization techniques to analyze the responses of a three-element thermoluminescent dosimeter (TLD) system. Specifically, the method determines the effective beta energy distribution incident on the dosimeter system, and thus the system performs as a beta spectrometer. Electron transport theory provides the mathematical model for performing the optimization calculation. In this calculation, parameters are determined that produce calculated doses for each of the chip/absorber components in the three-element TLD system. The resulting optimized parameters describe an effective incident beta distribution. This method can be used to determine the beta dose specifically at 7 mg X cm-2 or at any depth of interest. The doses at 7 mg X cm-2 in tissue determined by this method are compared to those experimentally determined using an extrapolation chamber. For a great variety of pure beta sources having different incident beta energy distributions, good agreement is found. The results are also compared to those produced by a commonly used empirical algorithm. Although the optimization method produces somewhat better results, the advantage of the optimization method is that its performance is not sensitive to the specific method of calibration

  13. Regression models in the determination of the absorbed dose with extrapolation chamber for ophthalmological applicators

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Morales P, R.

    1992-06-01

    The absorbed dose for equivalent soft tissue is determined,it is imparted by ophthalmologic applicators, ( 90 Sr/ 90 Y, 1850 MBq) using an extrapolation chamber of variable electrodes; when estimating the slope of the extrapolation curve using a simple lineal regression model is observed that the dose values are underestimated from 17.7 percent up to a 20.4 percent in relation to the estimate of this dose by means of a regression model polynomial two grade, at the same time are observed an improvement in the standard error for the quadratic model until in 50%. Finally the global uncertainty of the dose is presented, taking into account the reproducibility of the experimental arrangement. As conclusion it can infers that in experimental arrangements where the source is to contact with the extrapolation chamber, it was recommended to substitute the lineal regression model by the quadratic regression model, in the determination of the slope of the extrapolation curve, for more exact and accurate measurements of the absorbed dose. (Author)

  14. The absolute differential calculus calculus of tensors

    CERN Document Server

    Levi-Cività, Tullio

    1926-01-01

    Written by a towering figure of twentieth-century mathematics, this classic examines the mathematical background necessary for a grasp of relativity theory. Tullio Levi-Civita provides a thorough treatment of the introductory theories that form the basis for discussions of fundamental quadratic forms and absolute differential calculus, and he further explores physical applications.Part one opens with considerations of functional determinants and matrices, advancing to systems of total differential equations, linear partial differential equations, algebraic foundations, and a geometrical intro

  15. The absolute environmental performance of buildings

    DEFF Research Database (Denmark)

    Brejnrod, Kathrine Nykjær; Kalbar, Pradip; Petersen, Steffen

    2017-01-01

    Our paper presents a novel approach for absolute sustainability assessment of a building's environmental performance. It is demonstrated how the absolute sustainable share of the earth carrying capacity of a specific building type can be estimated using carrying capacity based normalization factors....... A building is considered absolute sustainable if its annual environmental burden is less than its share of the earth environmental carrying capacity. Two case buildings – a standard house and an upcycled single-family house located in Denmark – were assessed according to this approach and both were found...... to exceed the target values of three (almost four) of the eleven impact categories included in the study. The worst-case excess was for the case building, representing prevalent Danish building practices, which utilized 1563% of the Climate Change carrying capacity. Four paths to reach absolute...

  16. Determination of carcinogenic threshold limit values using the tumorigenic dose rate 50% (TD50)

    International Nuclear Information System (INIS)

    Bonvalot, Y.; Oudiz, A.; Hubert, P.; Abenhaim, L.

    1989-01-01

    The objective of the present study is to propose a simple procedure for the determination of Occupational Limit Values (OLVs) based on the TD 50 concept (Tumorigenic Dose Rate 50%). The TD 50 concept was introduced by Peto R. and al. to help classify chemical substances according to their carcinogenic potency. The TD 50 is that dose rate (in mg/KXg body weight/day) which, if administered chronically for the standard lifespan of the species will halve the probability of remaining tumorless throughout that period. Using TD 50 values available for 776 substances, the procedure presented here allows one to determine OLVs corresponding to a fixed excess risk. It is based on a mathematical high-to-low doses extrapolation of the TD 50 . OLVs obtained with this procedure are compared with currently available TLVs and other occupational guidelines. (author)

  17. Absolute measurement of the activity of 222Rn using a proportional counter

    International Nuclear Information System (INIS)

    Busch, Ingo; Greupner, Heinz; Keyser, Uwe

    2002-01-01

    A measuring set-up comprising a proportional counter of calculable 222 Rn efficiency and quantifiable active volume (δ V 222 Rn efficiency is determined by computer simulation of the measured α-spectra. The procedures necessary for absolute measurements by means of the counter are described, and the suitability of the counter for absolute measurements of the 222 Rn activity is proved by experiments. Thus, a new method for the realization of the unit of activity of 222 Rn is obtained, which is independent of the unit of activity of 226 Ra

  18. Absolute Summ

    Science.gov (United States)

    Phillips, Alfred, Jr.

    Summ means the entirety of the multiverse. It seems clear, from the inflation theories of A. Guth and others, that the creation of many universes is plausible. We argue that Absolute cosmological ideas, not unlike those of I. Newton, may be consistent with dynamic multiverse creations. As suggested in W. Heisenberg's uncertainty principle, and with the Anthropic Principle defended by S. Hawking, et al., human consciousness, buttressed by findings of neuroscience, may have to be considered in our models. Predictability, as A. Einstein realized with Invariants and General Relativity, may be required for new ideas to be part of physics. We present here a two postulate model geared to an Absolute Summ. The seedbed of this work is part of Akhnaton's philosophy (see S. Freud, Moses and Monotheism). Most important, however, is that the structure of human consciousness, manifest in Kenya's Rift Valley 200,000 years ago as Homo sapiens, who were the culmination of the six million year co-creation process of Hominins and Nature in Africa, allows us to do the physics that we do. .

  19. Combining Near-Subject Absolute and Relative Measures of Longitudinal Hydration in Hemodialysis

    OpenAIRE

    Chan, Cian; McIntyre, Christopher; Smith, David; Spanel, Patrik; Davies, Simon J.

    2009-01-01

    Background and objectives: The feasibility and additional value of combining bioimpedance analysis (BIA) with near-subject absolute measurement of total body water using deuterium dilution (TBWD) in determining longitudinal fluid status was investigated.

  20. Determination of the irradiation dose for the inhibition (D-10 radiation doses) of some gram negative and gram positive bacteria in peptone saline water

    International Nuclear Information System (INIS)

    Ayhan, H.; Tutluer, H.

    1994-01-01

    Determination of the irradiation dose for the inhibition of some pathogenic bacteria which cause food poisoning and spoilage were aimed. For this purpose, Salmonella typhi, Salmonella typhimurium,Salmonella enteridits,Klebsiella pneumonia, Pseudomonas fluorescence,Proteus vulgaris, Aeromonas hydrophila ,(gram-negative bacteria) and Bacillus cereus, Staphylococcus aureus strain 24,Staphylococcus aureus ATCC 6538 P,Staphylococcus epidermidis strain 115 and Clostridium perfringens A4TTK,(gram-positive bacteria) were used.Sensitivity of above mentioned bacteria to gamma rays (source Cs-137) was examined in saline with 0.1% peptone at different temperatures.Survivor plots (log.10 number of survivors versus dose) were determined by regression analysis of the data.Decimal reduction doses (D values in kGy) were calculated as the slope obtained from the regression analysis

  1. Double dosimetry procedures for the determination of occupational effective dose in interventional radiology

    International Nuclear Information System (INIS)

    Jaervinen, H.; Buls, N.; Clerinx, P.; Miljanic, S.; Ranogajec-Komor, M.; Nikodemova, D.; D'Errico, F.

    2008-01-01

    Full text: In interventional radiology, for an accurate determination of occupational effective dose, measurements with two dosemeters ('double dosimetry', DD) have been recommended, one dosemeter located above and one under the protective apron. In this paper, based on an extensive literature search, the most recent algorithms developed for the determination of effective dose from the dosimeter readings have been compared for a few practical interventional procedures. Recommendations on the practices and algorithms are given on the basis of the results. For the comparison of algorithms, dosemeter readings and the effective dose were obtained both experimentally and by calculation. Further, data from published Monte Carlo calculations have been applied. The literature review has indicated that very few regulations for DD exist and the DD practices have not been harmonized. There is no firm consensus on the most suitable calculation algorithms. Single dosemeter (SD) measurements are still mostly used for the calculation of effective dose. Most DD and SD algorithms overestimate effective dose significantly, sometimes by over ten times. However, SD algorithms can significantly underestimate effective dose in certain interventional radiology conditions. Due to the possibility of underestimating effective dose, DD is generally recommended. The results suggest that there might not be a single DD algorithm which would be optimum for all interventional radiology procedures. However, the selection of a precise DD algorithm for each individual condition is not practical and compromises must be made. For accurate personnel dosimetry, the accuracy of the algorithm selected should be tested for typical local interventional radiology condition. Personnel dosemeters should be used in the recommended positions. The dosemeter above the apron should be on a collar and its reading also used to assess the risk of lens injuries. The dosemeter under the apron can be on the chest or

  2. Absolute Determination of High DC Voltages by Means of Frequency Measurement

    Science.gov (United States)

    Peier, Dirk; Schulz, Bernd

    1983-01-01

    A novel absolute measuring procedure is presented for the definition of fixed points of the voltage in the 100 kV range. The method is based on transit time measurements with accelerated electrons. By utilizing the selective interaction of a monoenergetic electron beam with the electromagnetic field of a special cavity resonator, the voltage is referred to fundamental constants and the base unit second. Possible balance voltages are indicated by a current detector. Experimental investigations are carried out with resonators in the normal conducting range. With a copper resonator operating at the temperature of boiling nitrogen (77 K), the relative uncertainty of the voltage points is estimated to be +/- 4 × 10-4. The technically realizable uncertainty can be reduced to +/- 1 × 10-5 by the proposed application of a superconducting niobium resonator. Thus this measuring device becomes suitable as a primary standard for the high-voltage range.

  3. Absolute measurement of the $\\beta\\alpha$ decay of $^{16}$N

    CERN Multimedia

    We propose to study the $\\beta$-decay of $^{16}$N at ISOLDE with the aim of determining the branching ratio for $\\beta\\alpha$ decay on an absolute scale. There are indications that the previously measured branching ratio is in error by an amount significantly larger than the quoted uncertainty. This limits the precision with which the S-factor of the astrophysically important $^{12}$C($\\alpha, \\gamma)^{16}$O reaction can be determined.

  4. Synthesis and absolute configurations of the cytotoxic polyacetylenes isolated from the callus of Panax ginseng.

    Science.gov (United States)

    Fujimoto, Y; Satoh, M; Takeuchi, N; Kirisawa, M

    1990-06-01

    Panaxacol (1) and dihydropanaxacol (2), cytotoxic polyacetylenes isolated from the callus of Panax ginseng, were synthesized starting from D-(-)-diethyl tartrate. The absolute configuration of 1 was determined to be 9R, 10R and the absolute configuration at C-3 of 2 was tentatively assigned as 3S by the application of the R(+)-alpha-methoxy-alpha-(trifluoro methyl)phenylacetyl (MTPA) method.

  5. Absolute flux scale for radioastronomy

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Stankevich, K.S.

    1986-01-01

    The authors propose and provide support for a new absolute flux scale for radio astronomy, which is not encumbered with the inadequacies of the previous scales. In constructing it the method of relative spectra was used (a powerful tool for choosing reference spectra). A review is given of previous flux scales. The authors compare the AIS scale with the scale they propose. Both scales are based on absolute measurements by the ''artificial moon'' method, and they are practically coincident in the range from 0.96 to 6 GHz. At frequencies above 6 GHz, 0.96 GHz, the AIS scale is overestimated because of incorrect extrapolation of the spectra of the primary and secondary standards. The major results which have emerged from this review of absolute scales in radio astronomy are summarized

  6. A novel method for measuring patients' adherence to insulin dosing guidelines: introducing indicators of adherence

    Directory of Open Access Journals (Sweden)

    Cahané Michel

    2008-12-01

    Full Text Available Abstract Background Diabetic type 1 patients are often advised to use dose adjustment guidelines to calculate their doses of insulin. Conventional methods of measuring patients' adherence are not applicable to these cases, because insulin doses are not determined in advance. We propose a method and a number of indicators to measure patients' conformance to these insulin dosing guidelines. Methods We used a database of logbooks of type 1 diabetic patients who participated in a summer camp. Patients used a guideline to calculate the doses of insulin lispro and glargine four times a day, and registered their injected doses in the database. We implemented the guideline in a computer system to calculate recommended doses. We then compared injected and recommended doses by using five indicators that we designed for this purpose: absolute agreement (AA: the two doses are the same; relative agreement (RA: there is a slight difference between them; extreme disagreement (ED: the administered and recommended doses are merely opposite; Under-treatment (UT and over-treatment (OT: the injected dose is not enough or too high, respectively. We used weighted linear regression model to study the evolution of these indicators over time. Results We analyzed 1656 insulin doses injected by 28 patients during a three weeks camp. Overall indicator rates were AA = 45%, RA = 30%, ED = 2%, UT = 26% and OT = 30%. The highest rate of absolute agreement is obtained for insulin glargine (AA = 70%. One patient with alarming behavior (AA = 29%, RA = 24% and ED = 8% was detected. The monitoring of these indicators over time revealed a crescendo curve of adherence rate which fitted well in a weighted linear model (slope = 0.85, significance = 0.002. This shows an improvement in the quality of therapeutic decision-making of patients during the camp. Conclusion Our method allowed the measurement of patients' adherence to their insulin adjustment guidelines. The indicators that we

  7. Absolute surface reconstruction by slope metrology and photogrammetry

    Science.gov (United States)

    Dong, Yue

    Developing the manufacture of aspheric and freeform optical elements requires an advanced metrology method which is capable of inspecting these elements with arbitrary freeform surfaces. In this dissertation, a new surface measurement scheme is investigated for such a purpose, which is to measure the absolute surface shape of an object under test through its surface slope information obtained by photogrammetric measurement. A laser beam propagating toward the object reflects on its surface while the vectors of the incident and reflected beams are evaluated from the four spots they leave on the two parallel transparent windows in front of the object. The spots' spatial coordinates are determined by photogrammetry. With the knowledge of the incident and reflected beam vectors, the local slope information of the object surface is obtained through vector calculus and finally yields the absolute object surface profile by a reconstruction algorithm. An experimental setup is designed and the proposed measuring principle is experimentally demonstrated by measuring the absolute surface shape of a spherical mirror. The measurement uncertainty is analyzed, and efforts for improvement are made accordingly. In particular, structured windows are designed and fabricated to generate uniform scattering spots left by the transmitted laser beams. Calibration of the fringe reflection instrument, another typical surface slope measurement method, is also reported in the dissertation. Finally, a method for uncertainty analysis of a photogrammetry measurement system by optical simulation is investigated.

  8. The Absolute Deviation Rank Diagnostic Approach to Gear Tooth Composite Fault

    Directory of Open Access Journals (Sweden)

    Guangbin Wang

    2017-01-01

    Full Text Available Aiming at nonlinear and nonstationary characteristics of the different degree with single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, a method for the diagnosis of absolute deviation of gear faults is presented. The method uses ADAMS, respectively, set-up dynamics model of single fault gear tooth broken, pitting, and composite fault gear tooth broken-pitting, to obtain the result of different degree of broken teeth, pitting the single fault and compound faults in the meshing frequency, and the amplitude frequency doubling through simulating analysis. Through the comparison with the normal state to obtain the sensitive characteristic of the fault, the absolute value deviation diagnostic approach is used to identify the fault and validate it through experiments. The results show that absolute deviation rank diagnostic approach can realize the recognition of gear single faults and compound faults with different degrees and provide quick reference to determine the degree of gear fault.

  9. Using a Novel Absolute Ontogenetic Age Determination Technique to Calculate the Timing of Tooth Eruption in the Saber-Toothed Cat, Smilodon fatalis.

    Directory of Open Access Journals (Sweden)

    M Aleksander Wysocki

    Full Text Available Despite the superb fossil record of the saber-toothed cat, Smilodon fatalis, ontogenetic age determination for this and other ancient species remains a challenge. The present study utilizes a new technique, a combination of data from stable oxygen isotope analyses and micro-computed tomography, to establish the eruption rate for the permanent upper canines in Smilodon fatalis. The results imply an eruption rate of 6.0 millimeters per month, which is similar to a previously published average enamel growth rate of the S. fatalis upper canines (5.8 millimeters per month. Utilizing the upper canine growth rate, the upper canine eruption rate, and a previously published tooth replacement sequence, this study calculates absolute ontogenetic age ranges of tooth development and eruption in S. fatalis. The timing of tooth eruption is compared between S. fatalis and several extant conical-toothed felids, such as the African lion (Panthera leo. Results suggest that the permanent dentition of S. fatalis, except for the upper canines, was fully erupted by 14 to 22 months, and that the upper canines finished erupting at about 34 to 41 months. Based on these developmental age calculations, S. fatalis individuals less than 4 to 7 months of age were not typically preserved at Rancho La Brea. On the whole, S. fatalis appears to have had delayed dental development compared to dental development in similar-sized extant felids. This technique for absolute ontogenetic age determination can be replicated in other ancient species, including non-saber-toothed taxa, as long as the timing of growth initiation and growth rate can be determined for a specific feature, such as a tooth, and that growth period overlaps with the development of the other features under investigation.

  10. Using a Novel Absolute Ontogenetic Age Determination Technique to Calculate the Timing of Tooth Eruption in the Saber-Toothed Cat, Smilodon fatalis.

    Science.gov (United States)

    Wysocki, M Aleksander; Feranec, Robert S; Tseng, Zhijie Jack; Bjornsson, Christopher S

    2015-01-01

    Despite the superb fossil record of the saber-toothed cat, Smilodon fatalis, ontogenetic age determination for this and other ancient species remains a challenge. The present study utilizes a new technique, a combination of data from stable oxygen isotope analyses and micro-computed tomography, to establish the eruption rate for the permanent upper canines in Smilodon fatalis. The results imply an eruption rate of 6.0 millimeters per month, which is similar to a previously published average enamel growth rate of the S. fatalis upper canines (5.8 millimeters per month). Utilizing the upper canine growth rate, the upper canine eruption rate, and a previously published tooth replacement sequence, this study calculates absolute ontogenetic age ranges of tooth development and eruption in S. fatalis. The timing of tooth eruption is compared between S. fatalis and several extant conical-toothed felids, such as the African lion (Panthera leo). Results suggest that the permanent dentition of S. fatalis, except for the upper canines, was fully erupted by 14 to 22 months, and that the upper canines finished erupting at about 34 to 41 months. Based on these developmental age calculations, S. fatalis individuals less than 4 to 7 months of age were not typically preserved at Rancho La Brea. On the whole, S. fatalis appears to have had delayed dental development compared to dental development in similar-sized extant felids. This technique for absolute ontogenetic age determination can be replicated in other ancient species, including non-saber-toothed taxa, as long as the timing of growth initiation and growth rate can be determined for a specific feature, such as a tooth, and that growth period overlaps with the development of the other features under investigation.

  11. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  12. A global algorithm for estimating Absolute Salinity

    Science.gov (United States)

    McDougall, T. J.; Jackett, D. R.; Millero, F. J.; Pawlowicz, R.; Barker, P. M.

    2012-12-01

    The International Thermodynamic Equation of Seawater - 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density) than does Practical Salinity. When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic), Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg-1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p) in the world ocean. To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811). In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally).

  13. Rational functions with maximal radius of absolute monotonicity

    KAUST Repository

    Loczi, Lajos

    2014-05-19

    We study the radius of absolute monotonicity R of rational functions with numerator and denominator of degree s that approximate the exponential function to order p. Such functions arise in the application of implicit s-stage, order p Runge-Kutta methods for initial value problems and the radius of absolute monotonicity governs the numerical preservation of properties like positivity and maximum-norm contractivity. We construct a function with p=2 and R>2s, disproving a conjecture of van de Griend and Kraaijevanger. We determine the maximum attainable radius for functions in several one-parameter families of rational functions. Moreover, we prove earlier conjectured optimal radii in some families with 2 or 3 parameters via uniqueness arguments for systems of polynomial inequalities. Our results also prove the optimality of some strong stability preserving implicit and singly diagonally implicit Runge-Kutta methods. Whereas previous results in this area were primarily numerical, we give all constants as exact algebraic numbers.

  14. Is Dose Deformation–Invariance Hypothesis Verified in Prostate IGRT?

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Antoine, E-mail: antoine.simon@univ-rennes1.fr [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Le Maitre, Amandine; Nassef, Mohamed; Rigaud, Bastien [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Castelli, Joël [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Department of Radiotherapy, Centre Eugène Marquis, 35000 Rennes (France); Acosta, Oscar; Haigron, Pascal [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Lafond, Caroline; Crevoisier, Renaud de [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Department of Radiotherapy, Centre Eugène Marquis, 35000 Rennes (France)

    2017-03-15

    Purpose: To assess dose uncertainties resulting from the dose deformation–invariance hypothesis in prostate cone beam computed tomography (CT)–based image guided radiation therapy (IGRT), namely to evaluate whether rigidly propagated planned dose distribution enables good estimation of fraction dose distributions. Methods and Materials: Twenty patients underwent a CT scan for planning intensity modulated radiation therapy–IGRT delivering 80 Gy to the prostate, followed by weekly CT scans. Two methods were used to obtain the dose distributions on the weekly CT scans: (1) recalculating the dose using the original treatment plan; and (2) rigidly propagating the planned dose distribution. The cumulative doses were then estimated in the organs at risk for each dose distribution by deformable image registration. The differences between recalculated and propagated doses were finally calculated for the fraction and the cumulative dose distributions, by use of per-voxel and dose-volume histogram (DVH) metrics. Results: For the fraction dose, the mean per-voxel absolute dose difference was <1 Gy for 98% and 95% of the fractions for the rectum and bladder, respectively. The maximum dose difference within 1 voxel reached, however, 7.4 Gy in the bladder and 8.0 Gy in the rectum. The mean dose differences were correlated with gas volume for the rectum and patient external contour variations for the bladder. The mean absolute differences for the considered volume receiving greater than or equal to dose x (V{sub x}) of the DVH were between 0.37% and 0.70% for the rectum and between 0.53% and 1.22% for the bladder. For the cumulative dose, the mean differences in the DVH were between 0.23% and 1.11% for the rectum and between 0.55% and 1.66% for the bladder. The largest dose difference was 6.86%, for bladder V{sub 80Gy}. The mean dose differences were <1.1 Gy for the rectum and <1 Gy for the bladder. Conclusions: The deformation–invariance hypothesis was

  15. Equivalent dose determination in foraminifera: analytical description of the CO2--signal dose-response curve

    International Nuclear Information System (INIS)

    Hoffmann, D.; Woda, C.; Mangini, A.

    2003-01-01

    The dose-response of the CO 2 - signal (g=2.0006) in foraminifera with ages between 19 and 300 ka is investigated. The sum of two exponential saturation functions is an adequate function to describe the dose-response curve up to an additional dose of 8000 Gy. It yields excellent dating results but requires an artificial doses of at least 5000 Gy. For small additional doses of about 500 Gy the single exponential saturation function can be used to calculate a reliable equivalent dose D E , although it does not describ the dose-response for higher doses. The CO 2 - -signal dose-response indicates that the signal has two components of which one is less stable than the other

  16. Responses of absolute and specific enzyme activity to consecutive application of composted sewage sludge in a Fluventic Ustochrept.

    Directory of Open Access Journals (Sweden)

    Xiao Liu

    Full Text Available Composted sewage sludge (CS is considered a rich source of soil nutrients and significantly affects the physical, chemical, and biological characteristics of soil, but its effect on specific enzyme activity in soil is disregarded. The present experiment examined the absolute and specific enzyme activity of the enzymes involved in carbon, nitrogen, and phosphorus cycles, the diversity of soil microbial functions, and soil community composition in a Fluventic Ustochrept under a maize-wheat rotation system in North China during 2012-2015. Application of CS led to increase in MBC and in its ratio to both total organic carbon (TOC and microbial biomass nitrogen (MBN. Absolute enzyme activity, except that of phosphatase, increased in CS-treated soils, whereas specific activity of all the enzymes declined, especially at the highest dose of CS (45 t ha-1. The diversity of soil microbial community also increased in CS-treated soils, whereas its functional diversity declined at higher doses of CS owing to the lowered specific enzyme activity. These changes indicate that CS application induced the domination of microorganisms that are not metabolically active and those that use resources more efficiently, namely fungi. Redundancy analysis showed that fundamental alterations in soil enzyme activity depend on soil pH. Soil specific enzyme activity is affected more than absolute enzyme activity by changes in soil properties, especially soil microbial activity and composition of soil microflora (as judged by the following ratios: MBC/TOC, MBC/MBN, and TOC/LOC, that is labile organic carbon through the Pearson Correlation Coefficient. Specific enzyme activity is thus a more accurate parameter than absolute enzyme activity for monitoring the effect of adding CS on the activities and structure of soil microbial community.

  17. Determination of high level absorbed dose in a 60Co gamma ray field with ionization chambers

    International Nuclear Information System (INIS)

    Zhongying Li; Benjiang Mao; Lu Zhang

    1995-01-01

    This paper relates to the principles and methods for determining the absorbed dose of high energy photons radiation with ionization chambers, and its shows the doserate results of high level 60 Co γ-rays in water measured with Farmer chambers. The results with two kinds of chambers at a same point are consistent within 0.3%, and the total uncertainty is less than ± 4%. In the domestic intercomparison on determining high level absorbed dose in which 12 laboratories participated, the deviation of our result from the mean result of the intercomparison is -0.04% [Chen Yundong (1992). Summing up report on a high level absorbed dose intercomparison (in Chinese)]. (author)

  18. Measurement of multi-slice computed tomography dose profile with the Dose Magnifying Glass and the MOSkin radiation dosimeter

    International Nuclear Information System (INIS)

    Lian, C.P.L.; Wong, J.H.D.; Young, A.; Cutajar, D.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2013-01-01

    This study describes the application of two in-house developed dosimeters, the Dose Magnifying Glass (DMG) and the MOSkin dosimeter at the Centre for Medical Radiation Physics, University of Wollongong, Australia, for the measurement of CT dose profiles for a clinical diagnostic 16-slice MSCT scanner. Two scanner modes were used; axial mode and helical mode, and the effect of varying beam collimation and pitch was studied. With an increase in beam collimation in axial mode and an increase of CT pitch in helical mode, cumulative point dose at scanner isocentre decreased while FWHM increased. There was generally good agreement to within 3% between the acquired dose profiles obtained by the DMG and the film except at dose profile tails, where film over-responded by up to 30% due to its intrinsic depth dose dependence at low doses. -- Highlights: ► This study shows the CT beam profiles acquired with our institution's detectors. ► The DMG is a relative dosimeter calibrated to absolute MOSkin readings. ► There was good agreement between dose profiles acquired by the DMG and the film

  19. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  20. Absolute elastic cross sections for electron scattering from SF6

    International Nuclear Information System (INIS)

    Gulley, R.J.; Uhlmann, L.J.; Dedman, C.J.; Buckman, S.J.; Cho, H.; Trantham, K.W.

    2000-01-01

    Full text: Absolute differential cross sections for vibrationally elastic scattering of electrons from sulphur hexafluoride (SF 6 ) have been measured at fixed angles of 60 deg, 90 deg and 120 deg over the energy range of 5 to 15 eV, and also at 11 fixed energies between 2.7 and 75 eV for scattering angles between 10 deg and 180 deg. These measurements employ the magnetic angle-changing technique of Read and Channing in combination with the relative flow technique to obtain absolute elastic scattering cross sections at backward angles (135 deg to 180 deg) for incident energies below 15 eV. The results reveal some substantial differences with several previous determinations and a reasonably good level of agreement with a recent close coupling calculation

  1. Determination and Analysis of Ar-41 Dose Rate Characteristic at Thermal Column of Kartini Reactor

    International Nuclear Information System (INIS)

    Widarto; Sardjono, Y.

    2007-01-01

    Determination and Analysis of Ar-41 activity dose rate at the thermal column after shutdown of Kartini reactor has been done. Based on evaluation and analysis concluded that external dose rate is D = 1.606x10 -6 Sv/second and internal dose rate is 3.429x10 -1 1 Sv/second. It means that if employee work at the column thermal area for 15 minutes a day, 5 days a week, in a year will be 0.376 Sv still under dose rate limit i.e. 0.5 Sv, so that the column thermal facility is safely area. (author)

  2. Determination and reliability of dose coefficients for radiopharmaceuticals; Ermittlung der Zuverlaessigkeit von Dosiskoeffizienten fuer Radiopharmaka

    Energy Technology Data Exchange (ETDEWEB)

    Spielmann, V.; Li, W.B.; Zankl, M.; Oeh, U.

    2015-11-15

    The dose coefficients used in nuclear medicine for dose calculations of radiopharmaceuticals are based on recommendations by ICRP (International Commission on radiological protection) and the MIRD (Medical Internal Radiation Dose Committee) using mathematical models for the temporal activity distributions in organs and tissues (biokinetic models) and mathematical models of the human body. These models using an idealized human body do not include uncertainty estimations. The research project is aimed to determine the uncertainties and thus the reliability of the dose coefficients for radiopharmaceuticals and to identify the biokinetic and dosimetric parameters that contribute most of the uncertainties.

  3. Retrospective dosimetry: Preliminary use of the single aliquot regeneration (SAR) protocol for the measurement of quartz dose in young house bricks

    DEFF Research Database (Denmark)

    Banerjee, D.; Bøtter-Jensen, L.; Murray, A.S.

    1999-01-01

    with the expected values based on their known age and confirms the absolute accuracy of the SAR method. It is concluded that a similar to 18 mGy fallout dose component can be detected on a background of similar to 100 mGy; this detection limit is controlled by uncertainties in the natural dose rare measurement......In retrospective dosimetry, the total dose absorbed by some pre-existing dosemeters, such as house bricks or tiles, is used to derive the dose to the population arising from a nuclear accident. This paper uses the newly developed SAR protocol to determine the total dose in young house bricks from...... the vicinity of the Chernobyl reactor site and from Roskilde, Denmark. For these samples, it is shown that high precision (similar to 1%) on the mean estimates of total dose can be achieved with similar to 20 independent measurements. The SAR total dose estimates of two Danish house bricks agree...

  4. RBE/absorbed dose relationship of d(50)-Be neutrons determined for early intestinal tolerance in mice

    International Nuclear Information System (INIS)

    Gueulette, J.; Wambersie, A.

    1978-01-01

    RBE/absorbed dose relationship of d(50)-Be neutrons (ref.: 60 Co) was determined using intestinal tolerance in mice (LD50) after single and fractionated irradiation. RBE is 1.8 for a single fraction (about 1000 rad 60 Co dose); it increases when decreasing dose and reaches the plateau value of 2.8 for a 60 Co dose of about 200 rad. This RBE value is used for the clinical applications with the cyclotron 'Cyclone' at Louvain-la-Neuve [fr

  5. A simple calculation for the determination of organ or tissue dose from medical x-ray diagnosis for stomach and chest

    International Nuclear Information System (INIS)

    Nishizawa, Kanae

    1984-01-01

    A simple calculation method has been developed to determine the organ or tissue doses of patients for typical X-ray diagnoses. The absorbed doses related to radiation-induced stochastic effects were calculated based on the dosimetric parameters experimentally determined and technical parameters for X-ray diagnostic examinations. The present method is principally based on the TRA method for the beam therapy. The dosimetric parameters such as percentage depth-dose curves and isodose curves were measured with ionization chambers in the MixDP phantom. The distance from the incident surface of X-ray beams to the organ or tissue of interest was determined with a mathematical phantom, which was the modified version of the MIRD phantom for the average Japanese adult. The absorbed doses were determined with a simple table look-up method using a computer. The calculated doses were tabulated for various technical parameters of stomach and chest X-ray examinations. The present calculation was applied to the Rando woman phantom to compare with the phantom measurements. The calculated values agree with the experimental doses within 20% discrepancy. It was concluded that the present calculation method can determine organ or tissue doses very simply for various X-ray examinations and that it was valuable for the estimation of population doses and risks from X-ray diagnoses. (author)

  6. A global algorithm for estimating Absolute Salinity

    Directory of Open Access Journals (Sweden)

    T. J. McDougall

    2012-12-01

    Full Text Available The International Thermodynamic Equation of Seawater – 2010 has defined the thermodynamic properties of seawater in terms of a new salinity variable, Absolute Salinity, which takes into account the spatial variation of the composition of seawater. Absolute Salinity more accurately reflects the effects of the dissolved material in seawater on the thermodynamic properties (particularly density than does Practical Salinity.

    When a seawater sample has standard composition (i.e. the ratios of the constituents of sea salt are the same as those of surface water of the North Atlantic, Practical Salinity can be used to accurately evaluate the thermodynamic properties of seawater. When seawater is not of standard composition, Practical Salinity alone is not sufficient and the Absolute Salinity Anomaly needs to be estimated; this anomaly is as large as 0.025 g kg−1 in the northernmost North Pacific. Here we provide an algorithm for estimating Absolute Salinity Anomaly for any location (x, y, p in the world ocean.

    To develop this algorithm, we used the Absolute Salinity Anomaly that is found by comparing the density calculated from Practical Salinity to the density measured in the laboratory. These estimates of Absolute Salinity Anomaly however are limited to the number of available observations (namely 811. In order to provide a practical method that can be used at any location in the world ocean, we take advantage of approximate relationships between Absolute Salinity Anomaly and silicate concentrations (which are available globally.

  7. A double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]-basimglurant and absolute bioavailability after oral administration and concomitant intravenous microdose administration of [13C6]-labeled basimglurant in humans.

    Science.gov (United States)

    Guerini, Elena; Schadt, Simone; Greig, Gerard; Haas, Ruth; Husser, Christophe; Zell, Manfred; Funk, Christoph; Hartung, Thomas; Gloge, Andreas; Mallalieu, Navita L

    2017-02-01

    1. The emerging technique of employing intravenous microdose administration of an isotope tracer concomitantly with an [ 14 C]-labeled oral dose was used to characterize the disposition and absolute bioavailability of a novel metabotropic glutamate 5 (mGlu5) receptor antagonist under clinical development for major depressive disorder (MDD). 2. Six healthy volunteers received a single 1 mg [ 12 C/ 14 C]-basimglurant (2.22 MBq) oral dose and a concomitant i.v. tracer dose of 100 μg of [ 13 C 6 ]-basimglurant. Concentrations of [ 12 C]-basimglurant and the stable isotope [ 13 C 6 ]-basimglurant were determined in plasma by a specific LC/MS-MS method. Total [ 14 C] radioactivity was determined in whole blood, plasma, urine and feces by liquid scintillation counting. Metabolic profiling was conducted in plasma, urine, blood cell pellet and feces samples. 3. The mean absolute bioavailability after oral administration (F) of basimglurant was ∼67% (range 45.7-77.7%). The major route of [ 14 C]-radioactivity excretion, primarily in form of metabolites, was in urine (mean recovery 73.4%), with the remainder excreted in feces (mean recovery 26.5%). The median t max for [ 12 C]-basimglurant after the oral administration was 0.71 h (range 0.58-1.00) and the mean terminal half-life was 77.2 ± 38.5 h. Terminal half-life for the [ 14 C]-basimglurant was 178 h indicating presence of metabolites with a longer terminal half-life. Five metabolites were identified with M1-Glucuronide as major and the others in trace amounts. There was minimal binding of drug to RBCs. IV pharmacokinetics was characterized with a mean ± SD CL of 11.8 ± 7.4 mL/h and a Vss of 677 ± 229 L. 4. The double-tracer technique used in this study allowed to simultaneously characterize the absolute bioavailability and disposition characteristics of the new oral molecular entity in a single study.

  8. Experimental and theoretical determinations of the absolute ionization cross section of alkali metals by electron impact in the energy range from 100 to 2000 eV

    International Nuclear Information System (INIS)

    Jalin, Rene

    1972-01-01

    The absolute electron impact ionization cross sections for the alkali metals in the energy range between 100 eV and 2000 eV were measured by the non-modulated crossed beam technique. The neutral beam of alkali atoms is produced by a Knudsen cell and crossed at right angles with the electron beam. The ions formed are collected on a plate and their intensity determined with a D.C. amplifier. The neutral beam is condensed on a cold trap cooled with liquid nitrogen, this temperature being much lower than that required to obtain total condensation. The amount of metal deposited is measured by the isotopic dilution technique and by atomic absorption, and the density of the atoms in the neutral beam is calculated. The total absolute ionization cross sections can then be determined. All possible errors have been carefully analyzed and their magnitudes estimated. The absolute ionization cross section for Li at an energy of 500 eV is: Q Li = 0,358 x 10 -16 cm 2 . This value is half of that obtained by Mac Farland and Kinney. The partial ionization cross sections for the singly and multiply charged ions is determined with a mass spectrometer attached to this apparatus. For the singly charged ions, the variation of the cross section with the energy of the ionizing electrons is in agreement with the optically allowed transition law: Q = A log BE/E. From the variation of Q with E, the squared matrix elements of the transition moment (|M i |) 2 are determined for all the elements studied. New calculations of the ionization cross section of Li and Na were performed in the framework of the Born-Bethe approximation as modified by Gaudin and Botter to take into account collisions with large momentum variation of the incident electron. Hartree-Fock type wave functions for the ground state atom (tabulated by Clementi) were used. The calculated values are in good agreement with our experimental results and with the former theoretical results calculated by various methods. This work also

  9. Commissioning of the Absolute Luminosity For ATLAS Detector at the LHC

    DEFF Research Database (Denmark)

    Jakobsen, Sune

    To determine the total cross section and absolute luminosity in the ATLAS detector at the LHC via pp scattering under very small angles, a dedicated sub-detector called ALFA has been made. Several performance evaluation tests including a test beam campaign lead to improvements of the detector...

  10. Determination of quality factors by microdosimetry

    International Nuclear Information System (INIS)

    Al-Affan, I.A.M.; Watt, D.E.

    1987-01-01

    The application of microdose parameters for the specification of a revised scale of quality factors which would be applicable at low doses and dose rates is examined in terms of an original proposal by Rossi. Two important modifications are suggested to enable an absolute scale of quality factors to be constructed. Allowance should be made to allow for the dependence of the saturation threshold of lineal energy on the type of heavy charged particle. Also, an artificial saturation threshold should be introduced for electron tracks as a means of modifying the measurements made in the microdosimeter to the more realistic site sizes of nanometer dimensions. The proposed absolute scale of quality factors nicely encompasses the high RBEs of around 3 observed at low doses for tritium β rays and is consistent with the recent recommendation of the ICRP that the quality factor for fast neutrons be increased by a factor of two, assuming that there is no biological repair for the reference radiation. (orig.)

  11. Determination of quality factors by microdosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Al-Affan, I.A.M.; Watt, D.E.

    1987-03-15

    The application of microdose parameters for the specification of a revised scale of quality factors which would be applicable at low doses and dose rates is examined in terms of an original proposal by Rossi. Two important modifications are suggested to enable an absolute scale of quality factors to be constructed. Allowance should be made to allow for the dependence of the saturation threshold of lineal energy on the type of heavy charged particle. Also, an artificial saturation threshold should be introduced for electron tracks as a means of modifying the measurements made in the microdosimeter to the more realistic site sizes of nanometer dimensions. The proposed absolute scale of quality factors nicely encompasses the high RBEs of around 3 observed at low doses for tritium ..beta.. rays and is consistent with the recent recommendation of the ICRP that the quality factor for fast neutrons be increased by a factor of two, assuming that there is no biological repair for the reference radiation.

  12. Cooperative use of VCD and XRD for the determination of tetrahydrobenzoisoquinolines absolute configuration: a reliable proof of memory of chirality and retention of configuration in enediyne rearrangements.

    Science.gov (United States)

    Mondal, Shovan; Naubron, Jean-Valère; Campolo, Damien; Giorgi, Michel; Bertrand, Michéle P; Nechab, Malek

    2013-12-01

    The absolute configurations (AC) of azaheterocylic compounds resulting from the cascade rearrangement of enediynes involving only light atoms were unambiguously assigned by the joint use of vibrational circular dichroism (VCD) and copper radiation single crystal X-ray diffraction (XRD). These AC determinations proved that the rearrangements of enediynes proceeded with memory of chirality and retention of configuration. © 2013 Wiley Periodicals, Inc.

  13. Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

    Energy Technology Data Exchange (ETDEWEB)

    Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura; Kovac, Axel O., E-mail: axel.kovac@mumc.nl; Wijnhoven, Geert, E-mail: g.wijnhoven@mumc.nl [Maastricht University Medical Centre, Department of Radiology (Netherlands); Schurink, Geert Willem H., E-mail: gwh.schurink@mumc.nl; Mees, Barend, E-mail: barend.mees@mumc.nl [Maastricht University Medical Centre, Department of Vascular Surgery (Netherlands); Das, Marco, E-mail: m.das@mumc.nl; Wildberger, Joachim E., E-mail: j.wildberger@mumc.nl; Haan, Michiel W. de, E-mail: m.de.haan@mumc.nl; Jeukens, Cécile R. L. P. N., E-mail: cecile.jeukens@mumc.nl [Maastricht University Medical Centre, Department of Radiology (Netherlands)

    2017-03-15

    PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to procedure type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.

  14. Dose determination with nitro blue tetrazolium containing radiochromic dye films by measuring absorbed and reflected light

    DEFF Research Database (Denmark)

    Kovács, A.; Baranyai, M.; Wojnárovits, L.

    2000-01-01

    determination in a wide dose range both by absorbance and reflectance measurements. The concept of measuring reflected light from dose labels has been discussed earlier and emerged recently due to the requirement of introducing semiquantitative label dose indicators for quarantine control. The usefulness...... of the method was studied using the newly developed radiochromic dye films as well as already existing ones. (C) 2000 Elsevier Science Ltd. All rights reserved....

  15. Blood flow determinations utilizing digital densitometry

    International Nuclear Information System (INIS)

    Lois, F.; Mankovich, N.J.; Gomes, A.S.

    1987-01-01

    A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512 2 and 1024 2 mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024 2 and 512 2 imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024 2 matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512 2 and 1024 2 imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512 2 or 1024 2 imaging. The increased accuracy in vessel size determination with 1024 2 imaging makes this high resolution system potentially perferable to determine absolute blood flow. (orig.)

  16. Surface energy loss processes in XPS studied by absolute reflection electron energy loss spectroscopy

    International Nuclear Information System (INIS)

    Nagatomi, T.; Goto, K.

    2010-01-01

    The results of the investigation of the inelastic interaction of 300-3000 eV electrons with the Ni and Au surfaces by the analysis of absolute reflection electron energy loss spectroscopy (REELS) spectra were described. The present analysis enables the inelastic mean free path (IMFP), surface excitation parameter (SEP) and differential SEP (DSEP) to be obtained simultaneously from an absolute REELS spectrum. The obtained IMFPs for Ni and Au showed a good agreement with those calculated using the TPP-2M predictive equation. The present SEPs determined for Ni and Au were fitted to the Chen's formula describing the dependence of the SEP on the electron energy, and material parameters for Ni and Au in Chen's formula were proposed. The present DESPs were compared with the theoretical results, and a reasonable agreement between the experimentally determined DSEPs and theoretical results was confirmed. The MC modeling of calculating the REELS spectrum, in which energy loss processes due to surface excitations are taken into account, was also described. The IMFP, SEP and DSEP determined by the present absolute REELS analysis were employed to describe energy loss processes by inelastic scattering in the proposed MC simulation. The simulated REELS spectra were found to be in a good agreement with the experimental spectra for both Ni and Au.

  17. Cryogenic, Absolute, High Pressure Sensor

    Science.gov (United States)

    Chapman, John J. (Inventor); Shams. Qamar A. (Inventor); Powers, William T. (Inventor)

    2001-01-01

    A pressure sensor is provided for cryogenic, high pressure applications. A highly doped silicon piezoresistive pressure sensor is bonded to a silicon substrate in an absolute pressure sensing configuration. The absolute pressure sensor is bonded to an aluminum nitride substrate. Aluminum nitride has appropriate coefficient of thermal expansion for use with highly doped silicon at cryogenic temperatures. A group of sensors, either two sensors on two substrates or four sensors on a single substrate are packaged in a pressure vessel.

  18. Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff

    International Nuclear Information System (INIS)

    Jaervinen, H.; Buls, N.; Clerinx, P.; Jansen, J.; Miljanic, S.; Nikodemova, D.; Ranogajec-Komor, M.; D'Errico, F.

    2008-01-01

    In interventional radiology, for an accurate determination of effective dose to the staff, measurements with two dosemeters have been recommended, one located above and one under the protective apron. Such 'double dosimetry' practices and the algorithms used for the determination of effective dose were reviewed in this study by circulating a questionnaire and by an extensive literature search. The results indicated that regulations for double dosimetry almost do not exist and there is no firm consensus on the most suitable calculation algorithms. The calculation of effective dose is mainly based on the single dosemeter measurements, in which either personal dose equivalent, directly, (dosemeter below the apron) or a fraction of personal dose equivalent (dosemeter above the apron) is taken as an assessment of effective dose. The most recent studies suggest that there might not be just one double dosimetry algorithm that would be optimum for all interventional radiology procedures. Further investigations in several critical configurations of interventional radiology procedures are needed to assess the suitability of the proposed algorithms. (authors)

  19. Absolute single-ion solvation free energy scale in methanol determined by the lithium cluster-continuum approach.

    Science.gov (United States)

    Pliego, Josefredo R; Miguel, Elizabeth L M

    2013-05-02

    Absolute solvation free energy of the lithium cation in methanol was calculated by the cluster-continuum quasichemical theory of solvation. Clusters with up to five methanol molecules were investigated using X3LYP, MP2, and MP4 methods with DZVP, 6-311+G(2df,2p), TZVPP+diff, and QZVPP+diff basis sets and including the cluster solvation through the PCM and SMD continuum models. Our calculations have determined a value of -118.1 kcal mol(-1) for the solvation free energy of the lithium, in close agreement with a value of -116.6 kcal mol(-1) consistent with the TATB assumption. Using data of solvation and transfer free energy of a pair of ions, electrode potentials and pKa, we have obtained the solvation free energy of 25 ions in methanol. Our analysis leads to a value of -253.6 kcal mol(-1) for the solvation free energy of the proton, which can be compared with the value of -263.5 kcal mol(-1) obtained by Kelly et al. using the cluster pair approximation. Considering that this difference is due to the methanol surface potential, we have estimated that it corresponds to -0.429 V.

  20. A developmental study of latent absolute pitch memory.

    Science.gov (United States)

    Jakubowski, Kelly; Müllensiefen, Daniel; Stewart, Lauren

    2017-03-01

    The ability to recall the absolute pitch level of familiar music (latent absolute pitch memory) is widespread in adults, in contrast to the rare ability to label single pitches without a reference tone (overt absolute pitch memory). The present research investigated the developmental profile of latent absolute pitch (AP) memory and explored individual differences related to this ability. In two experiments, 288 children from 4 to12 years of age performed significantly above chance at recognizing the absolute pitch level of familiar melodies. No age-related improvement or decline, nor effects of musical training, gender, or familiarity with the stimuli were found in regard to latent AP task performance. These findings suggest that latent AP memory is a stable ability that is developed from as early as age 4 and persists into adulthood.

  1. SU-E-T-636: Investigation of Dose Variation in High Dose Radiation Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hyvarinen, M; Leventouri, T; Casey, C; Long, S [Florida Atlantic University, Boca Raton, FL (United States); Pella, S [South Florida Radiation Oncology and Florida Atlantic University, Boca Raton, FL (United States); Dumitru, N [University of Bucharest, Bucharest-magurele, Ilfov (Romania); Herrera, R [Louis Stokes VA Medical Center, Cleveland, OH (United States)

    2014-06-15

    Purpose: The purpose of this study is to revise most of the HDR types of treatments with their applicators and their localization challenges. Since every millimeter of misplacement counts the study will look into the necessity of increasing the immobilization for several types of applicators Methods: The study took over 136 plans generated by the treatment planning system (TPS) looking into the applicator's placement in regard to the organs at risk (OR) and simulated the three possible displacements at the hottest dose point on the critical organ for several accessories to evaluate the variation of the delivered dose at the point due to the displacement. Results: Significant dose variation was obtained for the Contura, Savi, MLM and Prostate applicators. Conclusion: This study data indicates that an improvement of the immobilization devices for HDR is absolutely necessary. Better applicator fixation devices are required too. Developing new immobilization devices for all the applicators is recommended. Florida Atlantic University may provide Travel reimbursements.

  2. Achieving Climate Change Absolute Accuracy in Orbit

    Science.gov (United States)

    Wielicki, Bruce A.; Young, D. F.; Mlynczak, M. G.; Thome, K. J; Leroy, S.; Corliss, J.; Anderson, J. G.; Ao, C. O.; Bantges, R.; Best, F.; hide

    2013-01-01

    The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

  3. Determining dose rate with a semiconductor detector - Monte Carlo calculations of the detector response

    Energy Technology Data Exchange (ETDEWEB)

    Nordenfors, C

    1999-02-01

    To determine dose rate in a gamma radiation field, based on measurements with a semiconductor detector, it is necessary to know how the detector effects the field. This work aims to describe this effect with Monte Carlo simulations and calculations, that is to identify the detector response function. This is done for a germanium gamma detector. The detector is normally used in the in-situ measurements that is carried out regularly at the department. After the response function is determined it is used to reconstruct a spectrum from an in-situ measurement, a so called unfolding. This is done to be able to calculate fluence rate and dose rate directly from a measured (and unfolded) spectrum. The Monte Carlo code used in this work is EGS4 developed mainly at Stanford Linear Accelerator Center. It is a widely used code package to simulate particle transport. The results of this work indicates that the method could be used as-is since the accuracy of this method compares to other methods already in use to measure dose rate. Bearing in mind that this method provides the nuclide specific dose it is useful, in radiation protection, since knowing what the relations between different nuclides are and how they change is very important when estimating the risks

  4. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  5. A phase I/II trial of intensity modulated radiation (IMRT) dose escalation with concurrent fixed-dose rate gemcitabine (FDR-G) in patients with unresectable pancreatic cancer.

    Science.gov (United States)

    Ben-Josef, Edgar; Schipper, Mathew; Francis, Isaac R; Hadley, Scott; Ten-Haken, Randall; Lawrence, Theodore; Normolle, Daniel; Simeone, Diane M; Sonnenday, Christopher; Abrams, Ross; Leslie, William; Khan, Gazala; Zalupski, Mark M

    2012-12-01

    Local failure in unresectable pancreatic cancer may contribute to death. We hypothesized that intensification of local therapy would improve local control and survival. The objectives were to determine the maximum tolerated radiation dose delivered by intensity modulated radiation with fixed-dose rate gemcitabine (FDR-G), freedom from local progression (FFLP), and overall survival (OS). Eligibility included pathologic confirmation of adenocarcinoma, radiographically unresectable, performance status of 0-2, absolute neutrophil count of ≥ 1,500/mm(3), platelets ≥ 100,000/mm(3), creatinine CRM (Time-to-Event Continual Reassessment Method) with the target dose-limiting toxicity (DLT) rate set to 0.25. Fifty patients were accrued. DLTs were observed in 11 patients: G3/4 anorexia, nausea, vomiting, and/or dehydration (7); duodenal bleed (3); duodenal perforation (1). The recommended dose is 55 Gy, producing a probability of DLT of 0.24. The 2-year FFLP is 59% (95% confidence interval [CI]: 32-79). Median and 2-year overall survival are 14.8 months (95% CI: 12.6-22.2) and 30% (95% CI 17-45). Twelve patients underwent resection (10 R0, 2 R1) and survived a median of 32 months. High-dose radiation therapy with concurrent FDR-G can be delivered safely. The encouraging efficacy data suggest that outcome may be improved in unresectable patients through intensification of local therapy. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Radiation dose determines the method for quantification of DNA double strand breaks

    International Nuclear Information System (INIS)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra; Todorović, Danijela

    2016-01-01

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  7. Real time determination of dose radiation through artificial intelligence and virtual reality

    International Nuclear Information System (INIS)

    Freitas, Victor G.G.; Mol, Antonio C.A.; Pereira, Claudio M.N.A.

    2009-01-01

    In the last years, a virtual environment of Argonauta research reactor, sited in the Instituto de Engenharia Nuclear (Brazil), has been developed. Such environment, called here Argonauta Virtual (AV), is a 3D model of the reactor hall, in which virtual people (avatar) can navigate. In AV, simulations of nuclear sources and doses are possible. In a recent work, a real time monitoring system (RTMS) was developed to provide (by means of Ethernet TCP/IP) the information of area detectors situated in the reactor hall. Extending the scope of AV, this work is intended to provide a continuous determination of gamma radiation dose in the reactor hall, based in several monitored parameters. To accomplish that a module based in artificial neural network (ANN) was developed. The ANN module is able to predict gamma radiation doses using as inputs: the avatar position (from virtual environment), the reactor power (from RTMS) and information of fixed area detectors (from RTMS). The ANN training data has been obtained by measurements of gamma radiation doses in a mesh of points, with previously defined positions, for different power levels. Through the use of ANN it is possible to estimate, in real time, the dose received by a person at any position in Argonauta reactor hall. Such approach allows tasks simulations and training of people inside the AV system, without exposing them to radiation effects. (author)

  8. Radiation dose determines the method for quantification of DNA double strand breaks

    Energy Technology Data Exchange (ETDEWEB)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra [University of Belgrade, Vinča Institute of Nuclear Sciences, Belgrade (Serbia); Todorović, Danijela, E-mail: dtodorovic@medf.kg.ac.rs [University of Kragujevac, Faculty of Medical Sciences, Kragujevac (Serbia)

    2016-03-15

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  9. Real time determination of dose radiation through artificial intelligence and virtual reality

    International Nuclear Information System (INIS)

    Freitas, Victor Goncalves Gloria

    2009-01-01

    In the last years, a virtual environment of Argonauta research reactor, sited in the Instituto de Engenharia Nuclear (Brazil), has been developed. Such environment, called here Argonauta Virtual (AV), is a 3D model of the reactor hall, in which virtual people (avatar) can navigate. In AV, simulations of nuclear sources and doses are possible. In a recent work, a real time monitoring system (RTMS) was developed to provide (by means of Ethernet TCP/I P) the information of area detectors situated in the reactor hall. Extending the scope of AV, this work is intended to provide a continuous determination of gamma radiation dose in the reactor hall, based in several monitored parameters. To accomplish that a module based in artificial neural network (ANN) was developed. The ANN module is able to predict gamma radiation doses using as inputs: the avatar position (from virtual environment), the reactor power (from RTMS) and information of fixed area detectors (from RTMS). The ANN training data has been obtained by measurements of gamma radiation doses in a mesh of points, with previously defined positions, for different power levels. Through the use of ANN it is possible to estimate, in real time, the dose received by a person at any position in Argonauta reactor hall. Such approach allows tasks simulations and training of people inside the AV system, without exposing them to radiation effects. (author)

  10. Errors and limits in the determination of plasma electron density by measuring the absolute values of the emitted continuum radiation intensity

    International Nuclear Information System (INIS)

    Bilbao, L.; Bruzzone, H.; Grondona, D.

    1994-01-01

    The reliable determination of a plasma electron structure requires a good knowledge of the errors affecting the employed technique. A technique based on the measurements of the absolute light intensity emitted by travelling plasma structures in plasma focus devices has been used, but it can be easily modified to other geometries and even to stationary plasma structures with time-varying plasma densities. The purpose of this work is to discuss in some detail the errors and limits of this technique. Three separate errors are shown: the minimum size of the density structure that can be resolved, an overall error in the measurements themselves, and an uncertainty in the shape of the density profile. (author)

  11. Absolute concentration determination of phosphorus metabolites in the Langendorff-perfused rabbit heart by phosphorus-31 nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Gard, J.K.

    1984-01-01

    The concentrations of mobile high energy phosphorus metabolites and intracellular pH of Langendorff-perfused rabbit heart have been determined under control and reduced flow conditions. Absolute concentration determination was accomplished by Lorentzian lineshape analysis after development of hexachlorocyclotriphosphazene as an external intensity standard. Hearts were demonstrated to be biochemically and physiologically competent during control perfusion periods and compromised during reduced flow conditions by independent hemodynamic and metabolic measurements coincident with the NMR experiment. Reduction in perfusate flow from 20 mL/min to 5.0 mL/min (25% flow) or 2.5 mL/min (12.5% flow) demonstrated a fall in phosphocreatine and adenosine triphosphate concentrations, a rise in cytosolic inorganic phosphate concentrations, and drops in pH. Subsequent recovery upon reflow was observed. The derived values for the free concentration of ADP were very close to the reported values of the Michaelis constant for respiratory stimulation, implicating a regulatory role for this molecule in cellular respiration. Strong evidence that the creating kinase reaction was in equilibrium in the 25% flow study was seen. The NMR observable correlated closely with myocardial performance and biochemical indices of metabolic function, and supported the use of phosphocreatine as an indicator of current metabolic integrity

  12. WE-E-18A-03: How Accurately Can the Peak Skin Dose in Fluoroscopy Be Determined Using Indirect Dose Metrics?

    International Nuclear Information System (INIS)

    Jones, A; Pasciak, A

    2014-01-01

    Purpose: Skin dosimetry is important for fluoroscopically-guided interventions, as peak skin doses (PSD) that Result in skin reactions can be reached during these procedures. The purpose of this study was to assess the accuracy of different indirect dose estimates and to determine if PSD can be calculated within ±50% for embolization procedures. Methods: PSD were measured directly using radiochromic film for 41 consecutive embolization procedures. Indirect dose metrics from procedures were collected, including reference air kerma (RAK). Four different estimates of PSD were calculated and compared along with RAK to the measured PSD. The indirect estimates included a standard method, use of detailed information from the RDSR, and two simplified calculation methods. Indirect dosimetry was compared with direct measurements, including an analysis of uncertainty associated with film dosimetry. Factors affecting the accuracy of the indirect estimates were examined. Results: PSD calculated with the standard calculation method were within ±50% for all 41 procedures. This was also true for a simplified method using a single source-to-patient distance (SPD) for all calculations. RAK was within ±50% for all but one procedure. Cases for which RAK or calculated PSD exhibited large differences from the measured PSD were analyzed, and two causative factors were identified: ‘extreme’ SPD and large contributions to RAK from rotational angiography or runs acquired at large gantry angles. When calculated uncertainty limits [−12.8%, 10%] were applied to directly measured PSD, most indirect PSD estimates remained within ±50% of the measured PSD. Conclusions: Using indirect dose metrics, PSD can be determined within ±50% for embolization procedures, and usually to within ±35%. RAK can be used without modification to set notification limits and substantial radiation dose levels. These results can be extended to similar procedures, including vascular and interventional oncology

  13. Effective and absolute cross sections for low-energy (1-30 eV) electron interactions with condensed biomolecules

    Science.gov (United States)

    Zheng, Yi; Sanche, Léon

    2018-06-01

    Ionizing radiation is intensively used for therapeutic [e.g., radiotherapy, brachytherapy, and targeted radionuclide therapy (TRT)], as well as for diagnostic medical imaging purposes. In these applications, the radiation dose given to the patient should be known and controlled. In conventional cancer treatments, absorbed dose calculations rely essentially on scattering cross sections (CSs) of the primary high-energy radiation. In more sophisticated treatments, such as combined radio- and chemo-therapy, a description of the details of energy deposits at the micro- and nano-scopic level is preferred to relate dose to radiobiological effectiveness or to evaluate doses at the biomolecular level, when radiopharmaceuticals emitting short-range radiation are delivered to critical molecular components of cancer cells (e.g., TRT). These highly radiotoxic compounds emit large densities of low-energy electrons (LEEs). More generally, LEE (0-30 eV) are emitted in large numbers by any type of high-energy radiation; i.e., about 30 000 per MeV of deposited primary energy. Thus, to optimize the effectiveness of several types of radiation treatments, the energy deposited by LEEs must be known at the level of the cell, nucleus, chromosome, or DNA. Such local doses can be evaluated by Monte Carlo (MC) calculations, which account event-by-event, for the slowing down of all generations of particles. In particular, these codes require as input parameters absolute LEE CSs for elastic scattering, energy losses, and direct damage to vital cellular molecules, particularly DNA, the main target of radiation therapy. In the last decade, such CSs have emerged in the literature. Furthermore, a method was developed to transform relative yields of damages into absolute CSs by measuring specific parameters in the experiments. In this review article, we first present a general description of dose calculations in biological media via MC simulation and give an overview of the CSs available from

  14. Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kroll, Florian; Karsch, Leonhard [OncoRay - National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, TU Dresden, 01307 Dresden (Germany); Pawelke, Jörg [OncoRay - National Center for Radiation Research in Oncology, Medical Faculty Carl Gustav Carus, TU Dresden, 01307 Dresden, Germany and Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiation Physics, P.O. Box 510119, 01314 Dresden (Germany)

    2013-08-15

    Purpose: Clinical QA in teletherapy as well as the characterization of experimental radiation sources for future medical applications requires effective methods for measuring three-dimensional (3D) dose distributions generated in a water-equivalent medium. Current dosimeters based on ionization chambers, diodes, thermoluminescence detectors, radiochromic films, or polymer gels exhibit various drawbacks: High quality 3D dose determination is either very sophisticated and expensive or requires high amounts of effort and time for the preparation or read out. New detectors based on scintillator blocks in combination with optical tomography are studied, since they have the potential to facilitate the desired cost-effective, transportable, and long-term stable dosimetry system that is able to determine 3D dose distributions with high spatial resolution in a short time.Methods: A portable detector prototype was set up based on a plastic scintillator block and four digital cameras. During irradiation the scintillator emits light, which is detected by the fixed cameras. The light distribution is then reconstructed by optical tomography, using maximum-likelihood expectation maximization. The result of the reconstruction approximates the 3D dose distribution. First performance tests of the prototype using laser light were carried out. Irradiation experiments were performed with ionizing radiation, i.e., bremsstrahlung (6 to 21 MV), electrons (6 to 21 MeV), and protons (68 MeV), provided by clinical and research accelerators.Results: Laser experiments show that the current imaging properties differ from the design specifications: The imaging scale of the optical systems is position dependent, ranging from 0.185 mm/pixel to 0.225 mm/pixel. Nevertheless, the developed dosimetry method is proven to be functional for electron and proton beams. Induced radiation doses of 50 mGy or more made 3D dose reconstructions possible. Taking the imaging properties into account, determined

  15. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water

    International Nuclear Information System (INIS)

    2000-01-01

    The International Atomic Energy Agency published in 1987 an International Code of Practice entitled 'Absorbed Dose Determination in Photon and Electron Beams' (IAEA Technical Reports Series No. 277 (TRS-277)), recommending procedures to obtain the absorbed dose in water from measurements made with an ionization chamber in external beam radiotherapy. A second edition of TRS-277 was published in 1997 updating the dosimetry of photon beams, mainly kilovoltage X rays. Another International Code of Practice for radiotherapy dosimetry entitled 'The Use of Plane-Parallel Ionization Chambers in High Energy Electron and Photon Beams' (IAEA Technical Reports Series No. 381 (TRS-381)) was published in 1997 to further update TRS-277 and complement it with respect to the area of parallel-plate ionization chambers. Both codes have proven extremely valuable for users involved in the dosimetry of the radiation beams used in radiotherapy. In TRS-277 the calibration of the ionization chambers was based on primary standards of air kerma; this procedure was also used in TRS-381, but the new trend of calibrating ionization chambers directly in a water phantom in terms of absorbed dose to water was introduced. The development of primary standards of absorbed dose to water for high energy photon and electron beams, and improvements in radiation dosimetry concepts, offer the possibility of reducing the uncertainty in the dosimetry of radiotherapy beams. The dosimetry of kilovoltage X rays, as well as that of proton and heavy ion beams, interest in which has grown considerably in recent years, can also be based on these standards. Thus a coherent dosimetry system based on standards of absorbed dose to water is possible for practically all radiotherapy beams. Many Primary Standard Dosimetry Laboratories (PSDLs) already provide calibrations in terms of absorbed dose to water at the radiation quality of 60 Co gamma rays. Some laboratories have extended calibrations to high energy photon and

  16. Determination of organ doses during radiological examinations and calculation of somatically significant dose

    International Nuclear Information System (INIS)

    Steiner, H.

    1980-01-01

    Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) may well be in need of modification; nevertheless the numerical estimation of SSD arrived at here appears to reflect the right order of magnitude for the estimation of somatic risk. The consideration of the threshold dose for somatic injury remains a problem. (orig./MG) [de

  17. Overcoming interference with the detection of a stable isotopically labeled microtracer in the evaluation of beclabuvir absolute bioavailability using a concomitant microtracer approach.

    Science.gov (United States)

    Jiang, Hao; Titsch, Craig; Zeng, Jianing; Jones, Barry; Joyce, Philip; Gandhi, Yash; Turley, Wesley; Burrell, Richard; Aubry, Anne F; Arnold, Mark E

    2017-09-05

    The oral absolute bioavailability of beclabuvir in healthy subjects was determined using a microdose (100μg) of the stable isotopically labeled tracer via intravenous (IV) infusion started after oral dosing of beclabuvir (150mg). To simultaneously analyze the concentrations of the IV microtracer ([ 13 C 6 ]beclabuvir) and beclabuvir in plasma samples, a liquid chromatography-triple quadrupole mass spectrometry (LC-MS/MS) method was initially developed. Surprisingly beclabuvir significantly interfered with the IV microtracer detection when using the selected reaction monitoring (SRM) in the assay. An interfering component from the drug substance was observed using a high resolution mass spectrometer (HRMS). The mass-to-charge (m/z) of the interfering component was -32ppm different from the nominal value for the IV microtracer and thus could not be differentiated in the SRM assay by the unit mass resolution. To overcome this interference, we evaluated two approaches by either monitoring an alternative product ion using the SRM assay or isolating the interfering component using the parallel reaction monitoring (PRM) assay on the HRMS. This case study has demonstrated two practical approaches for overcoming interferences with the detection of stable isotopically labeled IV microtracers in the evaluation of absolute bioavailability, which provides users the flexibility in using either LC-MS/MS or HRMS to mitigate unpredicted interferences in the assay to support microtracer absolute bioavailability studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Cell wall microstructure, pore size distribution and absolute density of hemp shiv

    Science.gov (United States)

    Jiang, Y.; Lawrence, M.; Ansell, M. P.; Hussain, A.

    2018-04-01

    This paper, for the first time, fully characterizes the intrinsic physical parameters of hemp shiv including cell wall microstructure, pore size distribution and absolute density. Scanning electron microscopy revealed microstructural features similar to hardwoods. Confocal microscopy revealed three major layers in the cell wall: middle lamella, primary cell wall and secondary cell wall. Computed tomography improved the visualization of pore shape and pore connectivity in three dimensions. Mercury intrusion porosimetry (MIP) showed that the average accessible porosity was 76.67 ± 2.03% and pore size classes could be distinguished into micropores (3-10 nm) and macropores (0.1-1 µm and 20-80 µm). The absolute density was evaluated by helium pycnometry, MIP and Archimedes' methods. The results show that these methods can lead to misinterpretation of absolute density. The MIP method showed a realistic absolute density (1.45 g cm-3) consistent with the density of the known constituents, including lignin, cellulose and hemi-cellulose. However, helium pycnometry and Archimedes' methods gave falsely low values owing to 10% of the volume being inaccessible pores, which require sample pretreatment in order to be filled by liquid or gas. This indicates that the determination of the cell wall density is strongly dependent on sample geometry and preparation.

  19. Improvement of dose determination using glass display of mobile phones for accident dosimetry

    International Nuclear Information System (INIS)

    Discher, M.; Woda, C.; Fiedler, I.

    2013-01-01

    Previous studies have demonstrated that mobile phones can be used as suitable emergency dosimeters in case of an accidental radiation overexposure. Glass samples extracted from displays of mobile phones are sensitive to ionizing radiation and can be measured using the thermoluminescence (TL) method. A non-radiation induced background signal (so-called zero dose signal) was observed which overlaps with the radiation induced signal and consequently limits the minimum detectable dose. Investigations of several glasses from different displays showed that it is possible to reduce the zero dose signal up to 90% by etching the glass surface with concentrated hydrofluoric acid. With this approach a reduction of the detection limit of a factor of four, corresponding to approximately 80 mGy, was achieved. Dosimetric properties of etched samples are presented and developed protocols validated by dose recovery tests under realistic conditions. With the improvements in sample preparation the proposed method of dose determination is a competitive alternative to OSL/TL measurements of electronic components and chip cards and provides a useful option for retrospective accident dosimetry. -- Highlights: ► Glass displays from mobile phones have good potential for emergency dosimetry. ► The background signal can be reduced by etching glass samples with hydrofluoric acid. ► The minimum detectable dose can be lowered to approximately 80 mGy

  20. Absolute near-infrared refractometry with a calibrated tilted fiber Bragg grating.

    Science.gov (United States)

    Zhou, Wenjun; Mandia, David J; Barry, Seán T; Albert, Jacques

    2015-04-15

    The absolute refractive indices (RIs) of water and other liquids are determined with an uncertainty of ±0.001 at near-infrared wavelengths by using the tilted fiber Bragg grating (TFBG) cladding mode resonances of a standard single-mode fiber to measure the critical angle for total internal reflection at the interface between the fiber and its surroundings. The necessary condition to obtain absolute RIs (instead of measuring RI changes) is a thorough characterization of the dispersion of the core mode effective index of the TFBG across the full range of its cladding mode resonance spectrum. This technique is shown to be competitive with the best available measurements of the RIs of water and NaCl solutions at wavelengths in the vicinity of 1550 nm.

  1. Determination of subcellular compartment sizes for estimating dose variations in radiotherapy

    International Nuclear Information System (INIS)

    Poole, Christopher M.; Ahnesjo, Anders; Enger, Shirin A.

    2015-01-01

    The variation in specific energy absorbed to different cell compartments caused by variations in size and chemical composition is poorly investigated in radiotherapy. The aim of this study was to develop an algorithm to derive cell and cell nuclei size distributions from 2D histology samples, and build 3D cellular geometries to provide Monte Carlo (MC)-based dose calculation engines with a morphologically relevant input geometry. Stained and unstained regions of the histology samples are segmented using a Gaussian mixture model, and individual cell nuclei are identified via thresholding. Delaunay triangulation is applied to determine the distribution of distances between the centroids of nearest neighbour cells. A pouring simulation is used to build a 3D virtual tissue sample, with cell radii randomised according to the cell size distribution determined from the histology samples. A slice with the same thickness as the histology sample is cut through the 3D data and characterised in the same way as the measured histology. The comparison between this virtual slice and the measured histology is used to adjust the initial cell size distribution into the pouring simulation. This iterative approach of a pouring simulation with adjustments guided by comparison is continued until an input cell size distribution is found that yields a distribution in the sliced geometry that agrees with the measured histology samples. The thus obtained morphologically realistic 3D cellular geometry can be used as input to MC-based dose calculation programs for studies of dose response due to variations in morphology and size of tumour/healthy tissue cells/nuclei, and extracellular material. (authors)

  2. Behavior of Multiclass Pesticide Residue Concentrations during the Transformation from Rose Petals to Rose Absolute.

    Science.gov (United States)

    Tascone, Oriane; Fillâtre, Yoann; Roy, Céline; Meierhenrich, Uwe J

    2015-05-27

    This study investigates the concentrations of 54 multiclass pesticides during the transformation processes from rose petal to concrete and absolute using roses spiked with pesticides as a model. The concentrations of the pesticides were followed during the process of transforming the spiked rose flowers from an organic field into concrete and then into absolute. The rose flowers, the concrete, and the absolute, as well as their transformation intermediates, were analyzed for pesticide content using gas chromatography/tandem mass spectrometry. We observed that all the pesticides were extracted and concentrated in the absolute, with the exception of three molecules: fenthion, fenamiphos, and phorate. Typical pesticides were found to be concentrated by a factor of 100-300 from the rose flowers to the rose absolute. The observed effect of pesticide enrichment was also studied in roses and their extracts from four classically phytosanitary treated fields. Seventeen pesticides were detected in at least one of the extracts. Like the case for the spiked samples in our model, the pesticides present in the rose flowers from Turkey were concentrated in the absolute. Two pesticides, methidathion and chlorpyrifos, were quantified in the rose flowers at approximately 0.01 and 0.01-0.05 mg kg(-1), respectively, depending on the treated field. The concentrations determined for the corresponding rose absolutes were 4.7 mg kg(-1) for methidathion and 0.65-27.25 mg kg(-1) for chlorpyrifos.

  3. Field dose radiation determination by active learning with Gaussian Process for autonomous robot guiding

    International Nuclear Information System (INIS)

    Freitas Naiff, Danilo de; Silveira, Paulo R.; Pereira, Claudio M.N.A.

    2017-01-01

    This article proposes an approach for determination of radiation dose pro le in a radiation-susceptible environment, aiming to guide an autonomous robot in acting on those environments, reducing the human exposure to dangerous amount of dose. The approach consists of an active learning method based on information entropy reduction, using log-normally warped Gaussian Process (GP) as surrogate model, resulting in non-linear online regression with sequential measurements. Experiments with simulated radiation dose fields of varying complexity were made, and results showed that the approach was effective in reconstruct the eld with high accuracy, through relatively few measurements. The technique was also shown some robustness in presence measurement noise, present in real measurements, by assuming Gaussian noise. (author)

  4. Field dose radiation determination by active learning with Gaussian Process for autonomous robot guiding

    Energy Technology Data Exchange (ETDEWEB)

    Freitas Naiff, Danilo de; Silveira, Paulo R.; Pereira, Claudio M.N.A., E-mail: danilonai1992@poli.ufrj.br, E-mail: paulo@lmp.ufrj.br, E-mail: cmnap@ien.gov.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil); Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    This article proposes an approach for determination of radiation dose pro le in a radiation-susceptible environment, aiming to guide an autonomous robot in acting on those environments, reducing the human exposure to dangerous amount of dose. The approach consists of an active learning method based on information entropy reduction, using log-normally warped Gaussian Process (GP) as surrogate model, resulting in non-linear online regression with sequential measurements. Experiments with simulated radiation dose fields of varying complexity were made, and results showed that the approach was effective in reconstruct the eld with high accuracy, through relatively few measurements. The technique was also shown some robustness in presence measurement noise, present in real measurements, by assuming Gaussian noise. (author)

  5. Integrable covariant law of energy-momentum conservation for a gravitational field with the absolute parallelism structure

    International Nuclear Information System (INIS)

    Asanov, G.S.

    1979-01-01

    It is shown the description of gravitational field in the riemannian space-time by means of the absolute parallelism structure makes it possible to formulate an integrable covariant law of energy-momentum conservation for gravitational field, by imposing on the energy-momentum tensor the condition of vanishing of the covariant divergence (in the sense of the absolute parallelism). As a result of taking into account covariant constraints for the tetrads of the absolute parallelism, the Lagrangian density turns out to be not geometrised anymore and leads to the unambiguous conservation law of the type mentioned in the N-body problem. Covariant field equations imply the existence of the special euclidean coordinates outside of static neighbourhoods of gravitationing bodies. In these coordinates determined by the tetrads of the absolute parallelism, the linear approximation is not connected with any noncovariant assumptions

  6. Dynamic determination of equivalent CT source models for personalized dosimetry

    Directory of Open Access Journals (Sweden)

    Rosendahl Stephan

    2017-09-01

    Full Text Available With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.

  7. NGS Absolute Gravity Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The NGS Absolute Gravity data (78 stations) was received in July 1993. Principal gravity parameters include Gravity Value, Uncertainty, and Vertical Gradient. The...

  8. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.

    Science.gov (United States)

    Esquinas, Pedro L; Tanguay, Jesse; Gonzalez, Marjorie; Vuckovic, Milan; Rodríguez-Rodríguez, Cristina; Häfeli, Urs O; Celler, Anna

    2016-12-01

    In the nuclear medicine department, the activity of radiopharmaceuticals is measured using dose calibrators (DCs) prior to patient injection. The DC consists of an ionization chamber that measures current generated by ionizing radiation (emitted from the radiotracer). In order to obtain an activity reading, the current is converted into units of activity by applying an appropriate calibration factor (also referred to as DC dial setting). Accurate determination of DC dial settings is crucial to ensure that patients receive the appropriate dose in diagnostic scans or radionuclide therapies. The goals of this study were (1) to describe a practical method to experimentally determine dose calibrator settings using a thyroid-probe (TP) and (2) to investigate the accuracy, reproducibility, and uncertainties of the method. As an illustration, the TP method was applied to determine 188 Re dial settings for two dose calibrator models: Atomlab 100plus and Capintec CRC-55tR. Using the TP to determine dose calibrator settings involved three measurements. First, the energy-dependent efficiency of the TP was determined from energy spectra measurements of two calibration sources ( 152 Eu and 22 Na). Second, the gamma emissions from the investigated isotope ( 188 Re) were measured using the TP and its activity was determined using γ-ray spectroscopy methods. Ambient background, scatter, and source-geometry corrections were applied during the efficiency and activity determination steps. Third, the TP-based 188 Re activity was used to determine the dose calibrator settings following the calibration curve method [B. E. Zimmerman et al., J. Nucl. Med. 40, 1508-1516 (1999)]. The interobserver reproducibility of TP measurements was determined by the coefficient of variation (COV) and uncertainties associated to each step of the measuring process were estimated. The accuracy of activity measurements using the proposed method was evaluated by comparing the TP activity estimates of 99m Tc

  9. Age and dose as determinants of times of appearance of radium-induced osteosarcomas in humans

    International Nuclear Information System (INIS)

    Stebbings, J.H.; Lucas, H.F.

    1983-01-01

    Determinants of time-until-tumor for bone sarcomas in US radium cases have been reevaluated. For the 57 measured female bone sarcoma cases exposed to 226 Ra and/or 228 Ra, ages at appearance of tumor are more strongly correlated with radium intake doses than are latency periods. Ages at appearance of tumor increase as initial radium intakes decrease. As many lower dose cases were iatrogenic cases exposed in mid-adult life, rather than about age 22 as for the dial worker cases, these results may be artifactual, resulting from an increased susceptability to sarcoma induction at older ages. Alternatively the time of appearance of a sarcoma may be in part directly determined by age. Both explanations find support in the literature. These results suggest that 226 228 Ra-induced bone sarcomas do have an expression period. The downturn in sarcoma incidence at very high doses may result from truncation of the expression period on its early side by the minimum induction period

  10. Absolute dose calibration of an X-ray system and dead time investigations of photon-counting techniques

    CERN Document Server

    Carpentieri, C; Ludwig, J; Ashfaq, A; Fiederle, M

    2002-01-01

    High precision concerning the dose calibration of X-ray sources is required when counting and integrating methods are compared. The dose calibration for a dental X-ray tube was executed with special dose calibration equipment (dosimeter) as function of exposure time and rate. Results were compared with a benchmark spectrum and agree within +-1.5%. Dead time investigations with the Medipix1 photon-counting chip (PCC) have been performed by rate variations. Two different types of dead time, paralysable and non-paralysable will be discussed. The dead time depends on settings of the front-end electronics and is a function of signal height, which might lead to systematic defects of systems. Dead time losses in excess of 30% have been found for the PCC at 200 kHz absorbed photons per pixel.

  11. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    International Nuclear Information System (INIS)

    Borg, J.; Christensen, P.

    1995-01-01

    The extrapolation chamber measurement method is the basic method for the determination of dose rates in beta radiation fields and the method has been used for the establishment of beta calibration fields. The paper describes important details of the method and presents results from the measurements of depth-dose profiles from different beta radiation fields with E max values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high sensitivity. GM responses were measured from exposures in different beta radiation fields using different filters in front of the GM detector and the paper discusses the possibility of using the results from GM measurements with two different filters in an unknown beta radiation field to obtain a value of the dose rate. (Author)

  12. A robust method for determining the absorbed dose to water in a phantom for low-energy photon radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T, E-mail: thorsten.schneider@ptb.de [Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig (Germany)

    2011-06-07

    The application of more and more low-energy photon radiation in brachytherapy-either in the form of low-dose-rate radioactive seeds such as Pd-103 or I-125 or in the form of miniature x-ray tubes-has induced greater interest in determining the absorbed dose to water in water in this energy range. As it seems to be hardly feasible to measure the absorbed dose with calorimetric methods in this low energy range, ionometric methods are the preferred choice. However, the determination of the absorbed dose to water in water by ionometric methods is difficult in this energy range. With decreasing energy, the relative uncertainty of the photon cross sections increases and as the mass energy transfer coefficients show a steep gradient, the spectra of the radiation field must be known precisely. In this work two ionometric methods to determine the absorbed dose to water are evaluated with respect to their sensitivity to the uncertainties of the spectra and of the atomic database. The first is the measurement of the air kerma free in air and the application of an MC-based conversion factor to the absorbed dose to water. The second is the determination of the absorbed dose to water by means of an extrapolation chamber as an integral part of a phantom. In the complementing MC-calculations, two assortments of spectra each of which is based on a separate unfolding procedure were used as well as two kinds of databases: the standard PEGS and the recently implemented NIST database of EGSnrc. Experimental results were obtained by using a parallel-plate graphite extrapolation chamber and a free-air chamber. In the case when the water kerma in a phantom is determined from the measurements of air kerma free in air, differences in the order of 10% were found, according to which the database or the kind of spectrum is used. In contrast to this, for the second method, the differences found were about 0.5%.

  13. Masses and K-line absolute magnitudes of γ Leonis and 35 Comae

    International Nuclear Information System (INIS)

    Deming, D.; Dykton, M.

    1979-01-01

    The visual binary system γ Leonis consists of two K giants whose total mass was found by Wilson to be less than 0.6M/sub sun/ when a distance was obtained from K-line absolute magnitudes of both components. Since the orbital period of the system is of order 600 years, the orbital solution has usually been regarded as the most likely explanation of the anomalous mass. We have investigated the uniqueness of the orbital solution. We find that the individual orbital elements are only poorly determined, but that a 3 /P 2 is known to within +- 10%. The anomalous mass of this binary system implies either extensive mass-loss or the need for revisions in the K-line absolute magnitudes. We also investigate the binary system 35 Comae. Wilson has noted that in this system the K-line absolute magnitude of the G8 III primary component implies a total mass of 8 M/sub sun/. However the A component of 35 Comae is not sufficiently luminous to justify such a large total mass. The system has a period of order 700 years, and the uniqueness of the orbital solution is therefore suspect. However, in this case also we have investigated the uniqueness of the orbital solution and find that individual orbital elements are poorly determined, but that a 3 /P 2 is known to within +- 17%. We point out that 35 Comae is known to be very metal rich, in contrast to γ Leonis which is metal poor. We conclude that a composition-dependent correction to the K-line absolute magnitudes provides the simplest explanation of these mass anomalies. Such a correction would also give better agreement with the trigonometric parallaxes of these binary systems

  14. SHORT-TERM TOXICITY STUDY IN RATS DOSED WITH PEPPERMINT OIL

    DEFF Research Database (Denmark)

    Thorup, I.; Würtzen, G.; Carstensen, J.

    1983-01-01

    creatinine content, lowered terminal body weight and caused histopathological changes in the liver and in the white matter of cerebellum. For menthol at all dose levels a significant increase in absolute and relative liver weights and vacuolisation of hepatocytes was found. No sign of encephalopathy...

  15. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  16. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  17. Evaluation of the Accuracy of Polymer Gels for Determining Electron Dose Distributions in the Presence of Small Heterogeneities.

    Science.gov (United States)

    Asl, R Ghahraman; Nedaie, H A; Banaee, N

    2017-12-01

    The aim of this study is to evaluate the application and accuracy of polymer gels for determining electron dose distributions in the presence of small heterogeneities made of bone and air. Different cylindrical phantoms containing MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gel were used under the slab phantoms during irradiation. MR images of the irradiated gel phantoms were obtained to determine their R2 (spin-spin) relaxation maps for conversion to absorbed dose. One- and 2-dimensional lateral dose profiles were acquired at depths of 1 and 4 cm for 8 and 15 MeV electron beams. The results were compared with the doses measured by a diode detector at the same positions. In addition, the dose distribution in the axial orientation was measured by the gel dosimeter. The slope and intercept for the R2 versus dose curve were 0.509 ± 0.002 Gy s and 4.581 ± 0.005 s, respectively. No significant variation in dose-R2 response was seen for the two electron energies within the applied dose ranges. The mean dose difference between the measured gel dose profiles was smaller than 3% compared to those measured by the diode detector. These results provide further demonstration that electron dose distributions are significantly altered in the presence of tissue inhomogeneities such as bone and air cavity and that MAGIC gel is a useful tool for 3-dimensional dose visualization and qualitative assessment of tissue inhomogeneity effects in electron beam dosimetry.

  18. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models

    International Nuclear Information System (INIS)

    Jarry, G; De Marco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-01-01

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  19. A Semiempirical Approach to the Determination of Daily Erythemal Doses.

    Science.gov (United States)

    Silva, Abel A; Yamamoto, Ana L C; Corrêa, Marcelo P

    2018-02-15

    The maintenance of ground-based instruments to measure the incidence of ultraviolet radiation (UVR) from the Sun demands strict and well-developed procedures. A piece of equipment can be out of service for a couple of weeks or months for calibration, repair or even the improvement of the facilities where it has been set up. However, the replacement of an instrument in such circumstances can be logistically and financially prohibitive. On the other hand, the lack of data can jeopardize a long-term experiment. In this study, we introduce a semiempirical approach to the determination of the theoretical daily erythemal dose (DED t ) for periods of instrumental absence in a tropical site. The approach is based on 5 years of ground-based measurements of daily erythemal dose (DED) linearly correlated with parameters of total ozone column (TOC) and reflectivity (R PC ) from the Ozone Monitoring Instrument (OMI) and the cosine of solar zenith angle at noon (SZA n ). Seventeen months of missing ground-based data were replaced with DED t , leading to a complete 5-year series of data. The lowest and the highest values of typical DED were 2411 ± 322 J m -2 (1σ) (winter) and 5263 ± 997 J m -2 (summer). The monthly integrated erythemal dose (mED) varied from 59 kJ m -2 (winter) to 162 kJ m -2 (summer). Both of them depended mainly on cos(SZA n ) and R PC . The 12-month integrated erythemal dose (12-ED) ranged from 1350 kJ m -2 to 1546 kJ m -2 , but it can depend significantly on other atmospheric parameter (maybe aerosols) not explicitly considered here. © 2018 The American Society of Photobiology.

  20. Comparison of measured and calculated radiation doses in granite around emplacement holes in the spent-fuel test: Climax, Nevada Test Site

    International Nuclear Information System (INIS)

    van Konynenburg, R.A.

    1982-01-01

    Lawrence Livermore National Laboratory (LLNL) has emplaced eleven spent nuclear-reactor fuel assemblies in the Climax granite at the Nevada Test Site as part of the DOE Nevada Nuclear-Waste Storage Investigations. One of our objectives is to study radiation effects on the rock. The neutron and gamma-ray doses to the rock have been determined by MORSE-L Monte Carlo calculations and measurements using optical absorption and thermoluminescence dosimeters and metal foils. We compare the results to date. Generally, good agreement is found in the spatial and time dependence of the doses, but some of the absolute dose results appear to differ by more than the expected uncertainties. Although the agreement is judged to be adequate for radiation effects studies, suggestions for improving the precision of the calculations and measurements are made

  1. Long-term temporal stability of the National Institute of Standards and Technology spectral irradiance scale determined with absolute filter radiometers

    International Nuclear Information System (INIS)

    Yoon, Howard W.; Gibson, Charles E.

    2002-01-01

    The temporal stability of the National Institute of Standards and Technology (NIST) spectral irradiance scale as measured with broadband filter radiometers calibrated for absolute spectral irradiance responsivity is described. The working standard free-electron laser (FEL) lamps and the check standard FEL lamps have been monitored with radiometers in the ultraviolet and the visible wavelength regions. The measurements made with these two radiometers reveal that the NIST spectral irradiance scale as compared with an absolute thermodynamic scale has not changed by more than 1.5% in the visible from 1993 to 1999. Similar measurements in the ultraviolet reveal that the corresponding change is less than 1.5% from 1995 to 1999. Furthermore, a check of the spectral irradiance scale by six different filter radiometers calibrated for absolute spectral irradiance responsivity based on the high-accuracy cryogenic radiometer shows that the agreement between the present scale and the detector-based scale is better than 1.3% throughout the visible to the near-infrared wavelength region. These results validate the assigned spectral irradiance of the widely disseminated NIST or NIST-traceable standard sources

  2. Investigating Absolute Value: A Real World Application

    Science.gov (United States)

    Kidd, Margaret; Pagni, David

    2009-01-01

    Making connections between various representations is important in mathematics. In this article, the authors discuss the numeric, algebraic, and graphical representations of sums of absolute values of linear functions. The initial explanations are accessible to all students who have experience graphing and who understand that absolute value simply…

  3. Thyroid neoplasia following low-dose radiation in childhood

    International Nuclear Information System (INIS)

    Ron, E.; Modan, B.; Preston, D.; Alfandary, E.; Stovall, M.; Boice, J.D. Jr.

    1989-01-01

    The thyroid gland is highly sensitive to the carcinogenic effects of ionizing radiation. Previously, we reported a significant increase of thyroid cancer and adenomas among 10,834 persons in Israel who received radiotherapy to the scalp for ringworm. These findings have now been extended with further follow-up and revised dosimetry. Overall, 98 thyroid tumors were identified among the exposed and 57 among 10,834 nonexposed matched population and 5392 sibling comparison subjects. An estimated thyroid dose of 9 cGy was linked to a fourfold (95% Cl = 2.3-7.9) increase of malignant tumors and a twofold (95% Cl = 1.3-3.0) increase of benign tumors. The dose-response relationship was consistent with linearity. Age was an important modifier of risk with those exposed under 5 years being significantly more prone to develop thyroid tumors than older children. The pattern of radiation risk over time could be described on the basis of a constant multiplication of the background rate, and an absolute risk model was not compatible with the observed data. Overall, the excess relative risk per cGy for thyroid cancer development after childhood exposure is estimated as 0.3, and the absolute excess risk as 13 per 10(6) PY-cGy. For benign tumors the estimated excess relative risk was 0.1 per cGy and the absolute risk was 15 per 10(6) PY-cGy

  4. The main sequence of NGC 6231 and the calibration of absolute magnitudes

    International Nuclear Information System (INIS)

    Garrison, R.F.

    1978-01-01

    The author presents a discussion of a new approach to the calibration of absolute magnitudes for MK spectral types. With the addition of the NGC 6231 main sequence down to A0, the material for the cluster fitting method using very carefully determined MK types is complete. (Auth.)

  5. Absorbed dose determination in water in medium energy x-ray beam

    International Nuclear Information System (INIS)

    Nisevic, G.; Spasic-Jokic, V.

    1998-01-01

    Absorbed dose determination in water phantom in medium energy X-ray beam, according to IAEA recommendations is given. This method is applied on Radiotherapy department of Military Academy Hospital in Belgrade. Reference points of measurements are on depth of 5 cm and 2 cm as it recommended in ref. Experimental results are shown in aim to introduce new dosimetric concept based on air kerma calibration factor recommended for application in our radiotherapy centers (author)

  6. SU-F-18C-11: Diameter Dependency of the Radial Dose Distribution in a Long Polyethylene Cylinder

    Energy Technology Data Exchange (ETDEWEB)

    Bakalyar, D; McKenney, S [Henry Ford Health System, Detroit, MI (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States)

    2014-06-15

    Purpose: The radial dose distribution in the central plane of a long cylinder following a long CT scan depends upon the diameter and composition of the cylinder. An understanding of this behavior is required for determining the spatial average of the dose in the central plane. Polyethylene, the material for construction of the TG200/ICRU phantom (30 cm in diameter) was used for this study. Size effects are germane to the principles incorporated in size specific dose estimates (SSDE); thus diameter dependency was explored as well. Method: ssuming a uniform cylinder and cylindrically symmetric conditions of irradiation, the dose distribution can be described using a radial function. This function must be an even function of the radial distance due to the conditions of symmetry. Two effects are accounted for: The direct beam makes its weakest contribution at the center while the contribution due to scatter is strongest at the center and drops off abruptly at the outer radius. An analytic function incorporating these features was fit to Monte Carlo results determined for infinite polyethylene cylinders of various diameters. A further feature of this function is that it is integrable. Results: Symmetry and continuity dictate a local extremum at the center which is a minimum for the larger sizes. The competing effects described above can Resultin an absolute maximum occurring between the center and outer edge of the cylinders. For the smallest cylinders, the maximum dose may occur at the center. Conclusion: An integrable, analytic function can be used to characterize the radial dependency of dose for cylindrical CT phantoms of various sizes. One use for this is to help determine average dose distribution over the central cylinder plane when equilibrium dose has been reached.

  7. Determining {sup 252}Cf source strength by absolute passive neutron correlation counting

    Energy Technology Data Exchange (ETDEWEB)

    Croft, S. [Oak Ridge National Laboratory, Oak Ridge, TN 37831-6166 (United States); Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2013-06-21

    Physically small, lightly encapsulated, radionuclide sources containing {sup 252}Cf are widely used for a vast variety of industrial, medical, educational and research applications requiring a convenient source of neutrons. For many quantitative applications, such as detector efficiency calibrations, the absolute strength of the neutron emission is needed. In this work we show how, by using a neutron multiplicity counter the neutron emission rate can be obtained with high accuracy. This provides an independent and alternative way to create reference sources in-house for laboratories such as ours engaged in international safeguards metrology. The method makes use of the unique and well known properties of the {sup 252}Cf spontaneous fission system and applies advanced neutron correlation counting methods. We lay out the foundation of the method and demonstrate it experimentally. We show that accuracy comparable to the best methods currently used by national bodies to certify neutron source strengths is possible.

  8. Conversion coefficients for determination of dispersed photon dose during radiotherapy: NRUrad input code for MCNP.

    Science.gov (United States)

    Shahmohammadi Beni, Mehrdad; Ng, C Y P; Krstic, D; Nikezic, D; Yu, K N

    2017-01-01

    Radiotherapy is a common cancer treatment module, where a certain amount of dose will be delivered to the targeted organ. This is achieved usually by photons generated by linear accelerator units. However, radiation scattering within the patient's body and the surrounding environment will lead to dose dispersion to healthy tissues which are not targets of the primary radiation. Determination of the dispersed dose would be important for assessing the risk and biological consequences in different organs or tissues. In the present work, the concept of conversion coefficient (F) of the dispersed dose was developed, in which F = (Dd/Dt), where Dd was the dispersed dose in a non-targeted tissue and Dt is the absorbed dose in the targeted tissue. To quantify Dd and Dt, a comprehensive model was developed using the Monte Carlo N-Particle (MCNP) package to simulate the linear accelerator head, the human phantom, the treatment couch and the radiotherapy treatment room. The present work also demonstrated the feasibility and power of parallel computing through the use of the Message Passing Interface (MPI) version of MCNP5.

  9. Determination of Absorbed Dose Using a Dosimetric Film

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Badita, E.; Mitru, E.

    2009-01-01

    This paper presents the absorbed dose measurements by means of the irradiated dosimetric reference films. The dose distributions were made by MULTIDATA film densitometer using RTD-4 software, in INFLPR Linear Accelerator Department

  10. Investigation of initial contamination for disposal medical infusion items and determination of sterilization dose

    International Nuclear Information System (INIS)

    Hu Jinhui; Xu Ziyan; Sun Naifeng; Yan Aoshuang; Gao Wei; Wang Binglin

    1993-01-01

    Statistical analyses on initial contamination of 624 disposal medical infusion items are made. The normal distribution of the initial contamination, the relation of initial contamination of inner and outer walls of disposal medical infusion items and the changes of initial contamination before irradiation are shown. The sterilized dose for disposal infusion is determined as 17.2 kGy using bioburden information. The SAL (sterility assurance level) dose is 10 6 . The SIP (device sample item proportion) is 1 and the average initial contamination is 7 CFU/item

  11. THE ABSOLUTE MAGNITUDES OF TYPE Ia SUPERNOVAE IN THE ULTRAVIOLET

    International Nuclear Information System (INIS)

    Brown, Peter J.; Roming, Peter W. A.; Ciardullo, Robin; Gronwall, Caryl; Hoversten, Erik A.; Pritchard, Tyler; Milne, Peter; Bufano, Filomena; Mazzali, Paolo; Elias-Rosa, Nancy; Filippenko, Alexei V.; Li Weidong; Foley, Ryan J.; Hicken, Malcolm; Kirshner, Robert P.; Gehrels, Neil; Holland, Stephen T.; Immler, Stefan; Phillips, Mark M.; Still, Martin

    2010-01-01

    We examine the absolute magnitudes and light-curve shapes of 14 nearby (redshift z = 0.004-0.027) Type Ia supernovae (SNe Ia) observed in the ultraviolet (UV) with the Swift Ultraviolet/Optical Telescope. Colors and absolute magnitudes are calculated using both a standard Milky Way extinction law and one for the Large Magellanic Cloud that has been modified by circumstellar scattering. We find very different behavior in the near-UV filters (uvw1 rc covering ∼2600-3300 A after removing optical light, and u ∼ 3000-4000 A) compared to a mid-UV filter (uvm2 ∼2000-2400 A). The uvw1 rc - b colors show a scatter of ∼0.3 mag while uvm2-b scatters by nearly 0.9 mag. Similarly, while the scatter in colors between neighboring filters is small in the optical and somewhat larger in the near-UV, the large scatter in the uvm2 - uvw1 colors implies significantly larger spectral variability below 2600 A. We find that in the near-UV the absolute magnitudes at peak brightness of normal SNe Ia in our sample are correlated with the optical decay rate with a scatter of 0.4 mag, comparable to that found for the optical in our sample. However, in the mid-UV the scatter is larger, ∼1 mag, possibly indicating differences in metallicity. We find no strong correlation between either the UV light-curve shapes or the UV colors and the UV absolute magnitudes. With larger samples, the UV luminosity might be useful as an additional constraint to help determine distance, extinction, and metallicity in order to improve the utility of SNe Ia as standardized candles.

  12. Approach To Absolute Zero

    Indian Academy of Sciences (India)

    more and more difficult to remove heat as one approaches absolute zero. This is the ... A new and active branch of engineering ... This temperature is called the critical temperature, Te' For sulfur dioxide the critical ..... adsorbent charcoal.

  13. Immunogenicity to poliovirus type 2 following two doses of fractional intradermal inactivated poliovirus vaccine: A novel dose sparing immunization schedule.

    Science.gov (United States)

    Anand, Abhijeet; Molodecky, Natalie A; Pallansch, Mark A; Sutter, Roland W

    2017-05-19

    The polio eradication endgame strategic plan calls for the sequential removal of Sabin poliovirus serotypes from the trivalent oral poliovirus vaccine (tOPV), starting with type 2, and the introduction of ≥1 dose of inactivated poliovirus vaccine (IPV), to maintain an immunity base against poliovirus type 2. The global removal of oral poliovirus type 2 was successfully implemented in May 2016. However, IPV supply constraints has prevented introduction in 21 countries and led to complete stock-out in >20 countries. We conducted a literature review and contacted corresponding authors of recent studies with fractional-dose IPV (fIPV), one-fifth of intramuscular dose administered intradermally, to conduct additional type 2 immunogenicity analyses of two fIPV doses compared with one full-dose IPV. Four studies were identified that assessed immunogenicity of two fIPV doses compared to one full-dose IPV. Two fractional doses are more immunogenic than 1 full-dose, with type 2 seroconversion rates improving between absolute 19-42% (median: 37%, pvaccine compared to one full-dose IPV. In response to the current IPV shortage, a schedule of two fIPV doses at ages 6 and 14weekshas been endorsed by technical oversight committees and has been introduced in some affected countries. Copyright © 2017. Published by Elsevier Ltd.

  14. Determination of beta radiation doses received by personnel involved in the mitigation of the Chernobyl accident

    International Nuclear Information System (INIS)

    Osanov, D.P.; Krjuchkov, V.P.; Shaks, A.I.

    1993-01-01

    During the accident at the Chernobyl nuclear power plant on April 26, 1986, and in the post-accident period, workers were exposed to beta and low-energy-photon radiation. This paper describes a method of retrospective estimation of skin doses from these radiations by correlating known doses from gamma radiation. Dose distributions of beta and gamma radiation in tissue-equivalent materials were both calculated and measured using multilayer thermoluminescent dosimeters placed at different site locations. It was determined that the doses to the skin from beta radiation exceeded the maximum doses to the whole-body from gamma radiation by 1 or even 2 orders of magnitude. It is concluded that nuclear power plants should be equipped with multilayer skin dosimeters in order to ensure accurate skin dosimetry. 16 refs., 13 figs., 3 tabs

  15. Beam intensity scanner system for three dimensional dose verification of IMRT

    International Nuclear Information System (INIS)

    Vahc, Young W.; Kwon, Ohyun; Park, Kwangyl; Park, Kyung R.; Yi, Byung Y.; Kim, Keun M.

    2003-01-01

    Patient dose verification is clinically one of the most important parts in the treatment delivery of radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in IMRT. Here we present beam intensity scanner (BInS) system for the pre-treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom-made software for dose conversion of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6 MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera-based scintillator (DVCS) will be processed by our custom made software to reproduce 3D- relative dose distribution. For the intensity modulated beam (IMB), the BInS calculates absorbed dose in absolute beam fluence which is used for the patient dose distribution. Using BInS, we performed various measurements related to IMRT and found the following: (1) The 3D-dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimation of dynamic and/or step MLC system. This is mostly due to leaf transmission, leaf penumbra scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multi leaf opening. These phenomena result in a fluence distribution that can be substantially different from the initial and calculated intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT. (author)

  16. Determination of gamma radiation dose for destruction of Salmonella spp. in chicken flesh

    International Nuclear Information System (INIS)

    Santos, Andreia Ferreira dos

    1997-01-01

    The aim of this study was to determinate: 1) the radio sensibility of Salmonella typhimurium ATCC 14028 in soy trypticase broth; 2) the radio sensibility of Salmonella typhimurium ATCC 14028 in chicken thigh and; 3) to recommend a radiation dose which can be non hazardous for human consumption

  17. Using thermoluminescence dosimetry (TLD) to determine the gonadal dose of patients under-going chest X-ray examinations at NKST hospital, Mkar

    International Nuclear Information System (INIS)

    Agba, E.H.; Akaagerger, N.B.; Kungur, S.T.

    2011-01-01

    The doses absorbed by the gonads of patients undergoing chest X-ray examinations at NKST Christian Hospital, Mkar was determined using the Thermoluminescence Dosimetry Technique of measurement. Also, the direct X-ray dose to the chest of patients undergoing the routine examinations was also determined using the Thermolumnescence Dosimetry technique of measurement. The mean gonadal dose and the X-ray dose to the patients were found to be 0.03±0.02μSv and 0.04±0.03mSv respectively after exposure. These X-ray doses to the patients is seen to be within the acceptable recommended X -ray dose limits of 1mGy recommended by ICRP.

  18. The Evaluation of personnel radiation dose and society radiation on RSG-GAS around as proposal determination of ALARA value

    International Nuclear Information System (INIS)

    Pande Made Udiyani; Puradwi IW

    2007-01-01

    Each nuclear installation to achieve radiation safety has to meet the ALARA concepts. The ALARA value of a nuclear installation should be enacted by regulator body. ALARA value can be determined by evaluation radiation exposure and dose acceptance of nuclear installation operation. As case study in Indonesia, ALARA assessment in nuclear installation is done at RSG-GAS reactor. Intention of this research is to determine gyration reference assess ALARA by evaluate radiation dose acceptance by RSG-GAS radiation personnel and the influence of RSG-GAS operation to presentation of radiation accepted by society which living around its. ALARA of RSG-GAS determined based on evaluation of measurement data of the radiation doses which is accepted by personnel radiation. While evaluation of radiation doses which is accepted by society in the radius 5 km of the RSG-GAS conducted to data result of calculation using program package of CAP-88 and measurement result with method of carborne survey. Result of radiation dose evaluation obtained which not pass dose definition for the radiation worker that is 50 mSv/year, and for society around RSG-GAS that is 5 mSv/year. Based on the result of evaluation hence obtained value of ALARA for RSG-GAS in value of gyration 17 - 50 mSv/year. (author)

  19. Absolute spectrophotometry of Nova Cygni 1975

    International Nuclear Information System (INIS)

    Kontizas, E.; Kontizas, M.; Smyth, M.J.

    1976-01-01

    Radiometric photoelectric spectrophotometry of Nova Cygni 1975 was carried out on 1975 August 31, September 2, 3. α Lyr was used as reference star and its absolute spectral energy distribution was used to reduce the spectrophotometry of the nova to absolute units. Emission strengths of Hα, Hβ, Hγ (in W cm -2 ) were derived. The Balmer decrement Hα:Hβ:Hγ was compared with theory, and found to deviate less than had been reported for an earlier nova. (author)

  20. The Pragmatics of "Unruly" Dative Absolutes in Early Slavic

    Directory of Open Access Journals (Sweden)

    Daniel E. Collins

    2011-08-01

    Full Text Available This chapter examines some uses of the dative absolute in Old Church Slavonic and in early recensional Slavonic texts that depart from notions of how Indo-European absolute constructions should behave, either because they have subjects coreferential with the (putative main-clause subjects or because they function as if they were main clauses in their own right. Such "noncanonical" absolutes have generally been written off as mechanistic translations or as mistakes by scribes who did not understand the proper uses of the construction. In reality, the problem is not with literalistic translators or incompetent scribes but with the definition of the construction itself; it is quite possible to redefine the Early Slavic dative absolute in a way that accounts for the supposedly deviant cases. While the absolute is generally dependent semantically on an adjacent unit of discourse, it should not always be regarded as subordinated syntactically. There are good grounds for viewing some absolutes not as dependent clauses but as independent sentences whose collateral character is an issue not of syntax but of the pragmatics of discourse.

  1. On the absorbed dose determination method in high energy electrons beams

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Oane, M.; Mitru, E.; Avadanei, C.

    2008-01-01

    The absorbed dose determination method in water for electron beams with energies in the range from 1 MeV to 50 MeV is presented herein. The dosimetry equipment for measurements is composed of an UNIDOS.PTW electrometer and different ionization chambers calibrated in air kerma in a Co 60 beam. Starting from the code of practice for high energy electron beams, this paper describes the method adopted by the secondary standard dosimetry laboratory (SSDL) in NILPRP - Bucharest

  2. The absolute chronology and thermal processing of solids in the solar protoplanetary disk

    DEFF Research Database (Denmark)

    Connelly, James; Bizzarro, Martin; Krot, Alexander N.

    2012-01-01

    Transient heating events that formed calcium-aluminum - rich inclusions (CAIs) and chondrules are fundamental processes in the evolution of the solar protoplanetary disk, but their chronology is not understood. Using U-corrected Pb-Pb dating, we determined absolute ages of individual CAIs and cho...

  3. Absolutyzm i pluralizm (ABSOLUTISM AND PLURALISM

    Directory of Open Access Journals (Sweden)

    Renata Ziemińska

    2005-06-01

    Full Text Available Alethic absolutism is a thesis that propositions can not be more or less true, that they are true or false for ever (if true at all and that their truth is independent on any circumstances of their assertion. In negative version, easier to defend, alethic absolutism claims the very same proposition can not be both true and false relative to circumstances of its assertion. Simple alethic pluralism is a thesis that we have many concepts of truth. It is a very good way to dissolve the controversy between alethic relativism and absolutism. Many philosophical concepts of truth are the best reason for such pluralism. If concept is meaning of a name, we have many concepts of truth because the name 'truth' was understood in many ways. The variety of meanings however can be superficial. Under it we can find one idea of truth expressed in correspondence truism or schema (T. The content of the truism is too poor to be content of anyone concept of truth, so it usually is connected with some picture of the world (ontology and we have so many concepts of truth as many pictures of the world. The authoress proposes the hierarchical pluralism with privileged classic (or correspondence in weak sense concept of truth as absolute property.Other author's publications:

  4. Tissue-specific Calibration of Real-time PCR Facilitates Absolute Quantification of Plasmid DNA in Biodistribution Studies

    Directory of Open Access Journals (Sweden)

    Joan K Ho

    2016-01-01

    Full Text Available Analysis of the tissue distribution of plasmid DNA after administration of nonviral gene delivery systems is best accomplished using quantitative real-time polymerase chain reaction (qPCR, although published strategies do not allow determination of the absolute mass of plasmid delivered to different tissues. Generally, data is expressed as the mass of plasmid relative to the mass of genomic DNA (gDNA in the sample. This strategy is adequate for comparisons of efficiency of delivery to a single site but it does not allow direct comparison of delivery to multiple tissues, as the mass of gDNA extracted per unit mass of each tissue is different. We show here that by constructing qPCR standard curves for each tissue it is possible to determine the dose of intact plasmid remaining in each tissue, which is a more useful parameter when comparing the fates of different formulations of DNA. We exemplify the use of this tissue-specific qPCR method by comparing the delivery of naked DNA, cationic DNA complexes, and neutral PEGylated DNA complexes after intramuscular injection. Generally, larger masses of intact plasmid were present 24 hours after injection of DNA complexes, and neutral complexes resulted in delivery of a larger mass of intact plasmid to the spleen.

  5. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  6. Introducing the Mean Absolute Deviation "Effect" Size

    Science.gov (United States)

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  7. Determining the 13C(α, n)16O absolute cross section through the concurrent application of ANC and THM and astrophysical consequences for the s-process in AGB-LMSs.

    Science.gov (United States)

    Trippella, Oscar; La Cognata, Marco

    2018-01-01

    The 13C(α, n)16O reaction is considered to be the most important neutron source for the s-process main component in low-mass asymptotic giant branch stars. No direct experimental data exist at very low energies and measurements performed through direct techniques show inconsistent results, mostly in their absolute values. In this context, we reversed the usual normalization procedure combining two indirect approaches, the asymptotic normalization coefficient and the Trojan Horse Method, to unambiguously determine the absolute value of the 13C(α, n)16O astrophysical S(E)-factor in the most relevant energy-region for astrophysics. Adopting the new reaction rate for the n-source in the NEWTON s-process nucleosynthesis code, astrophysical calculations show only limited variations, less than 1%, for those nuclei whose production is considered to be totally due to slow neutron captures.

  8. SHORT-TERM TOXICITY STUDY IN RATS DOSED WITH PULEGONE AND MENTHOL

    DEFF Research Database (Denmark)

    Thorup, I.; Würtzen, G.; Carstensen, J.

    1983-01-01

    creatinine content, lowered terminal body weight and caused histopathological changes in the liver and in the white matter of cerebellum. For menthol at all dose levels a significant increase in absolute and relative liver weights and vacuolisation of hepatocytes was found. No sign of encephalopathy...

  9. Determination method of inactivating minimal dose of gama radiation for Salmonella typhimurium

    International Nuclear Information System (INIS)

    Araujo, E.S.; Campos, H. de; Silva, D.M.

    1979-01-01

    A method for determination of minimal inactivating dose (MID) with Salmonella typhimurium is presented. This is a more efficient way to improve the irradiated vaccines. The MID found for S. thyphimurium 6.616 by binomial test was 0.55 MR. The method used allows to get a definite value for MID and requires less consumption of material, work and time in comparison with the usual procedure [pt

  10. Direct determination of absolute configuration: a vibrational circular dichroism study on dimethyl-substituted phenyloxiranes synthesized by Shi epoxidation

    DEFF Research Database (Denmark)

    Fristrup, Peter; Lassen, Peter Rygaard; Tanner, David Ackland

    2008-01-01

    obtained using DFT/B3LYP calculations, and the differences between experiment and theory are discussed. The absolute configuration at the benzylic position was established as being (R), (S) and (R) for the cis, trans and geminal dimethylsubstituted phenyloxiranes, respectively. In all three cases...

  11. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  12. Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose

    International Nuclear Information System (INIS)

    Almeida Junior, Airton T.; Campos, L.L.R.; Araujo, F.G.S.; Santos, M.A.P.; Nogueira, M.S.

    2014-01-01

    This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm 3 , collected in the state of Sao Paulo), Purple barite (density 2.95g/cm 3 , collected in the state of Bahia) and White barite (density 3.10g/cm 3 , collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated

  13. Development and validation of Monte Carlo dose computations for contrast-enhanced stereotactic synchrotron radiation therapy

    International Nuclear Information System (INIS)

    Vautrin, M.

    2011-01-01

    Contrast-enhanced stereotactic synchrotron radiation therapy (SSRT) is an innovative technique based on localized dose-enhancement effects obtained by reinforced photoelectric absorption in the tumor. Medium energy monochromatic X-rays (50 - 100 keV) are used for irradiating tumors previously loaded with a high-Z element. Clinical trials of SSRT are being prepared at the European Synchrotron Radiation Facility (ESRF), an iodinated contrast agent will be used. In order to compute the energy deposited in the patient (dose), a dedicated treatment planning system (TPS) has been developed for the clinical trials, based on the ISOgray TPS. This work focuses on the SSRT specific modifications of the TPS, especially to the PENELOPE-based Monte Carlo dose engine. The TPS uses a dedicated Monte Carlo simulation of medium energy polarized photons to compute the deposited energy in the patient. Simulations are performed considering the synchrotron source, the modeled beamline geometry and finally the patient. Specific materials were also implemented in the voxelized geometry of the patient, to consider iodine concentrations in the tumor. The computation process has been optimized and parallelized. Finally a specific computation of absolute doses and associated irradiation times (instead of monitor units) was implemented. The dedicated TPS was validated with depth dose curves, dose profiles and absolute dose measurements performed at the ESRF in a water tank and solid water phantoms with or without bone slabs. (author) [fr

  14. Absolute measurements of the fast neutron flux in the reactor RA

    Energy Technology Data Exchange (ETDEWEB)

    Berovic, N; Boreli, F; Dragin, R [Institute of Nuclear Sciences Boris Kidric, Department of physics, Vinca, Beograd (Serbia and Montenegro)

    1961-10-15

    The absolute neutron flux in the vertical VK-5 hole of the reactor RA was determined by using the {sup 27}Al (n, alpha) {sup 24}Na reaction, and by counting the {sup 24}Na - 2.5 MeV gamma line photopeak activity. A method for the determination of {sigma}{sub eff} as a mean value between the two large limiting cases of neutron spectra is used. The flux at the power level of 5 MW was found to be (2.5{+-}0.9){center_dot}10{sup 12}n/cm{sup 2}sec (author)

  15. Absolute Configuration of Andrographolide and Its Proliferation of Osteoblast Cell Lines

    Science.gov (United States)

    Chantrapromma, S.; Boonnak, N.; Pitakpornpreecha, T.; Yordthong, T.; Chidan Kumar, C. S.; Fun, H. K.

    2018-05-01

    Andrographolide, C20H30O5, is a labdane diterpenoid which was isolated from the leave of Andrographis paniculata. Its crystal structure is determined by single crystal X-ray diffraction: monoclinic, sp. gr. P21, Z = 2. Absolute configuration is determined by the refinement of the Flack parameter to 0.21(19). In the crystal, molecules are linked by O-H···O hydrogen bonds and C-H···O interactions into two dimensional network parallel to the (001) plane. Its proliferation of osteoblast cell lines is reported.

  16. Gafchromic EBT-XD film: Dosimetry characterization in high-dose, volumetric-modulated arc therapy.

    Science.gov (United States)

    Miura, Hideharu; Ozawa, Shuichi; Hosono, Fumika; Sumida, Naoki; Okazue, Toshiya; Yamada, Kiyoshi; Nagata, Yasushi

    2016-11-08

    Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%. © 2016 The Authors.

  17. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ( PST Λ) was then compared to those determined by TLD ( TLD Λ) and Monte Carlo ( MC Λ) techniques. A likely consensus Λ value was estimated as the arithmetic mean of the average Λ values determined by each of three different techniques. Results: The average PST Λ value for the three Advantage sources was found to be (0.676±0.026) cGyh -1 U -1 . Intersource variation in PST Λ was less than 0.01%. The PST Λ was within 2% of the reported MC Λ values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported TLD Λ. A likely consensus Λ value was estimated to be (0.688±0.026) cGyh -1 U -1 , similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686±0.033) cGyh -1 U -1 , the NASI (Chatsworth, CA) Model MED3633 (0.688±0.033) cGyh -1 U -1 , and the Best Medical (Springfield, VA) Model 2335 (0.685±0.033) cGyh -1 U -1 103 Pd sources. Conclusions: An independent Λ determination has been performed for the Advantage Pd-103 source. The PST Λ obtained in this work provides additional information

  18. Radiation sterilisation dose determination for lyophilised amnion membranes and lyophilised bone grafts

    International Nuclear Information System (INIS)

    Hilmy, N.; Basril, A.; Febrida, A.

    1999-01-01

    Radiation sterilisation of medical products is now well established in commercial scale and at present there are more than two hundred irradiation facilities in operation throughout the world. It is a cold sterilisation process without toxic chemical residues, high degree of safety and easy to control, so that it is a safe technology to sterilise human tissue grafts. According to ISO (International Organisation of Standard) No. 11137, radiation sterilisation dose should be established based on the number of product's bioburden (number of product's contaminated microbes before irradiation). Bioburden of lyophilised amnion membranes and lyophilised bone grafts produced by Batan Research Tissue Bank (BRTB) have been determined since 1990 and 1994 consecutively by using 100 up to 120 pieces of samples per year. Results show that the average bioburden of the amnion membranes were 1.4 ( 0.2 x 103; 1.2 (0.2 x 103; 1.2 ( 1.2 x 103; 4.5 ( 0.5 x 102; 1.8 ( 0.9 x 102; 2.4 ( 2.3 x 102; 1.7(l.5 x 102; 1.5 ( 1.7 x 102 cells per sample, calculated in 1990 to 1997 consecutively and the average bioburden of the bonegrafts were 1.5 (0.4x 101; 0.25 (0.12 x 101; 0; 0 cells per sample, calculated in 1994 to 1997 consecutively. Morphological of those contaminants were found to be Gram positive coccoid forms (98%) and Gram positive vegetative rod (2%) with the D10 - values of 0.25 to 0.50 kGy. No spore forming bacteria and Gram negative bacteria were found in those contaminations. The highest bioburden of lyophilised amnion membranes and lyophilised bone grafts were found to be 4900 and 80 cells per sample consecutively, and the lowest was found to be 0 cell per sample in both of materials observed. According to ISO 11137 radiation sterilisation doses for amnion membranes were ranging between 21 to 25 kGy and for bone grafts was around 15 kGy with the Sterility Assurance Level (SAL) of 106. Since 1990, radiation sterilisation dose used for lyophilised amnion membranes produced by BRTB

  19. Application of the personnel photographic monitoring method to determine equivalent radiation dose beyond proton accelerator shielding

    International Nuclear Information System (INIS)

    Gel'fand, E.K.; Komochkov, M.M.; Man'ko, B.V.; Salatskaya, M.I.; Sychev, B.S.

    1980-01-01

    Calculations of regularities to form radiation dose beyond proton accelerator shielding are carried out. Numerical data on photographic monitoring dosemeter in radiation fields investigated are obtained. It was shown how to determine the total equivalent dose of radiation fields beyond proton accelerator shielding by means of the photographic monitoring method by introduction into the procedure of considering nuclear emulsions of division of particle tracks into the black and grey ones. A comparison of experimental and calculational data has shown the applicability of the used calculation method for modelling dose radiation characteristics beyond proton accelerator shielding [ru

  20. Impact of dose-distribution uncertainties on rectal ntcp modeling I: Uncertainty estimates

    International Nuclear Information System (INIS)

    Fenwick, John D.; Nahum, Alan E.

    2001-01-01

    A trial of nonescalated conformal versus conventional radiotherapy treatment of prostate cancer has been carried out at the Royal Marsden NHS Trust (RMH) and Institute of Cancer Research (ICR), demonstrating a significant reduction in the rate of rectal bleeding reported for patients treated using the conformal technique. The relationship between planned rectal dose-distributions and incidences of bleeding has been analyzed, showing that the rate of bleeding falls significantly as the extent of the rectal wall receiving a planned dose-level of more than 57 Gy is reduced. Dose-distributions delivered to the rectal wall over the course of radiotherapy treatment inevitably differ from planned distributions, due to sources of uncertainty such as patient setup error, rectal wall movement and variation in the absolute rectal wall surface area. In this paper estimates of the differences between planned and treated rectal dose-distribution parameters are obtained for the RMH/ICR nonescalated conformal technique, working from a distribution of setup errors observed during the RMH/ICR trial, movement data supplied by Lebesque and colleagues derived from repeat CT scans, and estimates of rectal circumference variations extracted from the literature. Setup errors and wall movement are found to cause only limited systematic differences between mean treated and planned rectal dose-distribution parameter values, but introduce considerable uncertainties into the treated values of some dose-distribution parameters: setup errors lead to 22% and 9% relative uncertainties in the highly dosed fraction of the rectal wall and the wall average dose, respectively, with wall movement leading to 21% and 9% relative uncertainties. Estimates obtained from the literature of the uncertainty in the absolute surface area of the distensible rectal wall are of the order of 13%-18%. In a subsequent paper the impact of these uncertainties on analyses of the relationship between incidences of bleeding

  1. Absolute determination of the gelling point of gelatin under quasi-thermodynamic equilibrium.

    Science.gov (United States)

    Bellini, Franco; Alberini, Ivana; Ferreyra, María G; Rintoul, Ignacio

    2015-05-01

    Thermodynamic studies on phase transformation of biopolymers in solution are useful to understand their nature and to evaluate their technological potentials. Thermodynamic studies should be conducted avoiding time-related phenomena. This condition is not easily achieved in hydrophilic biopolymers. In this contribution, the simultaneous effects of pH, salt concentration, and cooling rate (Cr) on the folding from random coil to triple helical collagen-like structures of gelatin were systematically studied. The phase transformation temperature at the absolute invariant condition of Cr = 0 °C/min (T(T)Cr=0) ) is introduced as a conceptual parameter to study phase transformations in biopolymers under quasi-thermodynamic equilibrium and avoiding interferences coming from time-related phenomena. Experimental phase diagrams obtained at different Cr are presented. The T(T)(Cr=0) compared with pH and TT(Cr=0) compared with [NaCl] diagram allowed to explore the transformation process at Cr = 0 °C/min. The results were explained by electrostatic interactions between the biopolymers and its solvation milieu. © 2015 Institute of Food Technologists®

  2. A radon progeny sampler for the determination of effective dose

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, S.B. [Australian Radiation Laboratory, Victoria (Australia)

    1997-12-01

    The design and simulated performance is described of a two-stage sampler (HE-Sampler) for {sup 222}Rn progeny. This HE-Sampler has a collection efficiency optimised to match the particle size dependency of the radon progeny dose conversion factor (DCF), derived from the latest Respiratory Tract Model of the International Commission on Radiological Protection, as implemented in the computer code RADEP. The He-Sampler comprises a wire screen pre-separator, matched to the nasal deposition, and a wire screen collector, matched to the respiratory tract collection. This HE-Sampler allows for the estimation of the radiation dose from the inhalation of {sup 222}Rn progeny, derived from two concurrent alpha particle activity measurements, one on the HE-Sampler screen collector and one on a reference filter sample. As a first approximation, the DCF is proportional to the collected fraction. The HE-Sampler response was simulated for a range of radon progeny size distributions to determine the error in the estimated DCF values. The simulation results show that the HE-Sampler is relatively insensitive to variations in sampling rate and in the screen parameters, particularly for environmental exposure. (Author).

  3. A Phase I/II Trial of Intensity Modulated Radiation (IMRT) Dose Escalation With Concurrent Fixed-dose Rate Gemcitabine (FDR-G) in Patients With Unresectable Pancreatic Cancer

    International Nuclear Information System (INIS)

    Ben-Josef, Edgar; Schipper, Mathew; Francis, Isaac R.; Hadley, Scott; Ten-Haken, Randall; Lawrence, Theodore; Normolle, Daniel; Simeone, Diane M.; Sonnenday, Christopher; Abrams, Ross; Leslie, William; Khan, Gazala; Zalupski, Mark M.

    2012-01-01

    Purpose: Local failure in unresectable pancreatic cancer may contribute to death. We hypothesized that intensification of local therapy would improve local control and survival. The objectives were to determine the maximum tolerated radiation dose delivered by intensity modulated radiation with fixed-dose rate gemcitabine (FDR-G), freedom from local progression (FFLP), and overall survival (OS). Methods and Materials: Eligibility included pathologic confirmation of adenocarcinoma, radiographically unresectable, performance status of 0-2, absolute neutrophil count of ≥1500/mm 3 , platelets ≥100,000/mm 3 , creatinine 2 /100 min intravenously) was given on days −22 and −15, 1, 8, 22, and 29. Intensity modulated radiation started on day 1. Dose levels were escalated from 50-60 Gy in 25 fractions. Dose-limiting toxicity was defined as gastrointestinal toxicity grade (G) ≥3, neutropenic fever, or deterioration in performance status to ≥3 between day 1 and 126. Dose level was assigned using TITE-CRM (Time-to-Event Continual Reassessment Method) with the target dose-limiting toxicity (DLT) rate set to 0.25. Results: Fifty patients were accrued. DLTs were observed in 11 patients: G3/4 anorexia, nausea, vomiting, and/or dehydration (7); duodenal bleed (3); duodenal perforation (1). The recommended dose is 55 Gy, producing a probability of DLT of 0.24. The 2-year FFLP is 59% (95% confidence interval [CI]: 32-79). Median and 2-year overall survival are 14.8 months (95% CI: 12.6-22.2) and 30% (95% CI 17-45). Twelve patients underwent resection (10 R0, 2 R1) and survived a median of 32 months. Conclusions: High-dose radiation therapy with concurrent FDR-G can be delivered safely. The encouraging efficacy data suggest that outcome may be improved in unresectable patients through intensification of local therapy.

  4. Accuracy assessment of pharmacogenetically predictive warfarin dosing algorithms in patients of an academic medical center anticoagulation clinic.

    Science.gov (United States)

    Shaw, Paul B; Donovan, Jennifer L; Tran, Maichi T; Lemon, Stephenie C; Burgwinkle, Pamela; Gore, Joel

    2010-08-01

    The objectives of this retrospective cohort study are to evaluate the accuracy of pharmacogenetic warfarin dosing algorithms in predicting therapeutic dose and to determine if this degree of accuracy warrants the routine use of genotyping to prospectively dose patients newly started on warfarin. Seventy-one patients of an outpatient anticoagulation clinic at an academic medical center who were age 18 years or older on a stable, therapeutic warfarin dose with international normalized ratio (INR) goal between 2.0 and 3.0, and cytochrome P450 isoenzyme 2C9 (CYP2C9) and vitamin K epoxide reductase complex subunit 1 (VKORC1) genotypes available between January 1, 2007 and September 30, 2008 were included. Six pharmacogenetic warfarin dosing algorithms were identified from the medical literature. Additionally, a 5 mg fixed dose approach was evaluated. Three algorithms, Zhu et al. (Clin Chem 53:1199-1205, 2007), Gage et al. (J Clin Ther 84:326-331, 2008), and International Warfarin Pharmacogenetic Consortium (IWPC) (N Engl J Med 360:753-764, 2009) were similar in the primary accuracy endpoints with mean absolute error (MAE) ranging from 1.7 to 1.8 mg/day and coefficient of determination R (2) from 0.61 to 0.66. However, the Zhu et al. algorithm severely over-predicted dose (defined as >or=2x or >or=2 mg/day more than actual dose) in twice as many (14 vs. 7%) patients as Gage et al. 2008 and IWPC 2009. In conclusion, the algorithms published by Gage et al. 2008 and the IWPC 2009 were the two most accurate pharmacogenetically based equations available in the medical literature in predicting therapeutic warfarin dose in our study population. However, the degree of accuracy demonstrated does not support the routine use of genotyping to prospectively dose all patients newly started on warfarin.

  5. Direct determination of the absorbed dose to water from 125I low dose-rate brachytherapy seeds using the new absorbed dose primary standard developed at ENEA-INMRI

    International Nuclear Information System (INIS)

    Toni, M.P.; Pimpinella, M.; Pinto, M.; Quini, M.; Cappadozzi, G.; Silvestri, C.; Bottauscio, O.

    2012-01-01

    Low-intensity radioactive sources emitting low-energy photons are used in the clinic for low dose-rate brachytherapy treatments of tumours. The dosimetry of these sources is based on reference air kerma rate measurements. The absorbed dose rate to water at the reference depth d 0 = 1 cm, D w , 1 cm, is then obtained by a conversion procedure with a large relative standard uncertainty of about 5%. This paper describes a primary standard developed at ENEA-INMRI to directly measure D w , 1 cm due to LDR sources. The standard is based on a large-angle and variable-volume ionization chamber, embedded in a graphite phantom and operating under 'wall-less air chamber' conditions. A set of correction and conversion factors, based on experiments and Monte Carlo simulations, are determined to obtain the value of D w , 1 cm from measurements of increment of ionization current with increasing chamber volume. The relative standard uncertainty on D w , 1 cm is 2.6%, which is appreciably lower than the current uncertainty. Characteristics of the standard, its associated uncertainty budget, and some experimental results are given for 125 I BEBIG I25.S16.C brachytherapy seeds. Finally, results of the experimental determination of the dose-rate constant 1 cm, traceable to the D w , 1 cm and the low-energy air kerma ENEA-INMRI standards, are given. The relative standard uncertainty on 1 cm is 2.9%, appreciably lower than the typical uncertainty (4.8%) of the values available in the literature. (authors)

  6. Testicular dose in prostate cancer radiotherapy. Impact on impairment of fertility and hormonal function

    Energy Technology Data Exchange (ETDEWEB)

    Boehmer, D.; Badakhshi, H.; Budach, V. [Dept. of Radiation Oncology, Charite - Univ. Clinic - Campus Mitte, Berlin (Germany); Kuschke, W.; Bohsung, J. [Dept. of Medical Physics, Charite - Univ. Clinic - Campus Mitte, Berlin (Germany)

    2005-03-01

    Purpose: to determine the dose received by the unshielded testicles during a course of 20-MV conventional external-beam radiotherapy for patients with localized prostate cancer. Critical evaluation of the potential impact on fertility and hormonal impairment in these patients according to the literature. Patients and methods: the absolute dose received by the testicles of 20 randomly selected patients undergoing radiotherapy of prostate cancer was measured by on-line thermoluminescence dosimetry. Patients were treated in supine position with an immobilization cushion under their knees. A flexible tube, containing three calibrated thermoluminescence dosimeters (TLDs) was placed on top or underneath the testicle closest to the perineal region with a day-to-day alternation. The single dose to the planning target volume was 1.8 Gy. Ten subsequent testicle measurements were performed on each patient. The individual TLDs were then read out and the total absorbed dose was calculated. Results: the mean total dose ({+-} standard deviation) measured in a series of 10 subsequent treatment days in all patients was 49 cGy ({+-} 36 cGy). The calculated projected doses made on a standard series of 40 fractions of external-beam radiotherapy were 196 cGy ({+-} 145 cGy). The results of this study are appraised with the available data in the literature. Conclusion: the dose received by the unshielded testes can be assessed as a risk for permanent infertility and impairment of hormonal function in prostate cancer patients treated with external-beam radiotherapy. (orig.)

  7. Absolute instrumental neutron activation analysis at Lawrence Livermore Laboratory

    International Nuclear Information System (INIS)

    Heft, R.E.

    1977-01-01

    The Environmental Science Division at Lawrence Livermore Laboratory has in use a system of absolute Instrumental Neutron Activation Analysis (INAA). Basically, absolute INAA is dependent upon the absolute measurement of the disintegration rates of the nuclides produced by neutron capture. From such disintegration rate data, the amount of the target element present in the irradiated sample is calculated by dividing the observed disintegration rate for each nuclide by the expected value for the disintegration rate per microgram of the target element that produced the nuclide. In absolute INAA, the expected value for disintegration rate per microgram is calculated from nuclear parameters and from measured values of both thermal and epithermal neutron fluxes which were present during irradiation. Absolute INAA does not depend on the concurrent irradiation of elemental standards but does depend on the values for thermal and epithermal neutron capture cross-sections for the target nuclides. A description of the analytical method is presented

  8. A review of radiology staff doses and dose monitoring requirements

    International Nuclear Information System (INIS)

    Martin, C. J.

    2009-01-01

    Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand. (authors)

  9. Experimental ratio between the 'real' dose per organ and the calculated dose determined by means of the Embalse nuclear power plant's personal dosimeter

    International Nuclear Information System (INIS)

    Thomasz, E.; Salas, C.A.

    1987-01-01

    The specific purpose of the study was to determine the experimental ratio between the reading of dosimeters used by the personnel of the Embalse nuclear power plant and the 'real' dose absorbed by the worker in different organs. An anthropomorphic phantom ALDERSON internal and externally loaded with approximately 150 TLD crystals was used. This phantom was placed in five enclosures that were usually occupied by workers of the Embalse nuclear power plant. In this way, the average dose per organ and the effective equivalent dosis in each enclosure could be calculated and compared with the personal dosimeters placed over the thorax and the conversion factor rem/rem for each enclosure was determined. The average factor resulting from the five considered enclosures was 0.73 rem/rem. This means that the personal dosimeters over value the real dosis absorbed by the personnel of the Embalse nuclear power plant in approximately 37%. (Author)

  10. Dose Determination of Activated Charcoal in Management of ...

    African Journals Online (AJOL)

    Purpose: To assess the doses of activated charcoal currently used in the management of acute amitriptyline-induced drug poisoning and explore the possibility of using lower doses. Methods: Albino male Wistar rats, weighing 200 ± 20 g, were used for the study. The animals were divided into four groups of eight animals ...

  11. Determination of line edge roughness in low-dose top-down scanning electron microscopy images

    NARCIS (Netherlands)

    Verduin, T.; Kruit, P.; Hagen, C.W.

    2014-01-01

    We investigated the off-line metrology for line edge roughness (LER) determination by using the discrete power spectral density (PSD). The study specifically addresses low-dose scanning electron microscopy (SEM) images in order to reduce the acquisition time and the risk of resist shrinkage. The

  12. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  13. Globular Clusters: Absolute Proper Motions and Galactic Orbits

    Science.gov (United States)

    Chemel, A. A.; Glushkova, E. V.; Dambis, A. K.; Rastorguev, A. S.; Yalyalieva, L. N.; Klinichev, A. D.

    2018-04-01

    We cross-match objects from several different astronomical catalogs to determine the absolute proper motions of stars within the 30-arcmin radius fields of 115 Milky-Way globular clusters with the accuracy of 1-2 mas yr-1. The proper motions are based on positional data recovered from the USNO-B1, 2MASS, URAT1, ALLWISE, UCAC5, and Gaia DR1 surveys with up to ten positions spanning an epoch difference of up to about 65 years, and reduced to Gaia DR1 TGAS frame using UCAC5 as the reference catalog. Cluster members are photometrically identified by selecting horizontal- and red-giant branch stars on color-magnitude diagrams, and the mean absolute proper motions of the clusters with a typical formal error of about 0.4 mas yr-1 are computed by averaging the proper motions of selected members. The inferred absolute proper motions of clusters are combined with available radial-velocity data and heliocentric distance estimates to compute the cluster orbits in terms of the Galactic potential models based on Miyamoto and Nagai disk, Hernquist spheroid, and modified isothermal dark-matter halo (axisymmetric model without a bar) and the same model + rotating Ferre's bar (non-axisymmetric). Five distant clusters have higher-than-escape velocities, most likely due to large errors of computed transversal velocities, whereas the computed orbits of all other clusters remain bound to the Galaxy. Unlike previously published results, we find the bar to affect substantially the orbits of most of the clusters, even those at large Galactocentric distances, bringing appreciable chaotization, especially in the portions of the orbits close to the Galactic center, and stretching out the orbits of some of the thick-disk clusters.

  14. Prediction of absolute infrared intensities for the fundamental vibrations of H2O2

    Science.gov (United States)

    Rogers, J. D.; Hillman, J. J.

    1981-01-01

    Absolute infrared intensities are predicted for the vibrational bands of gas-phase H2O2 by the use of a hydrogen atomic polar tensor transferred from the hydroxyl hydrogen atom of CH3OH. These predicted intensities are compared with intensities predicted by the use of a hydrogen atomic polar tensor transferred from H2O. The predicted relative intensities agree well with published spectra of gas-phase H2O2, and the predicted absolute intensities are expected to be accurate to within at least a factor of two. Among the vibrational degrees of freedom, the antisymmetric O-H bending mode nu(6) is found to be the strongest with a calculated intensity of 60.5 km/mole. The torsional band, a consequence of hindered rotation, is found to be the most intense fundamental with a predicted intensity of 120 km/mole. These results are compared with the recent absolute intensity determinations for the nu(6) band.

  15. PC based system for absolute neutron flux-spectrum measurements. Final report for the period 1 April 1994 - 15 December 1997

    International Nuclear Information System (INIS)

    Dobrea, D.

    1998-01-01

    When measuring absolute neutron flux-spectra, thin detector foils are irradiated in a neutron field. The absolute activity of isotopes generated by activation or fission reactions (fission products) is then measured, using an efficiency calibrated high resolution gamma-ray spectroscopy system, and the absolute reaction rates for their production is determined. Finally the flux-spectrum is determined based upon the reaction rate values. A general method to obtain flux-spectra from the reaction rate is the unfolding method. The above process involves computations of photopeak area, reaction rate, flux perturbation corrections and flux-spectrum. The PC's are well suited for the data processing system outlined above. Using available interfaces, the PC's can be involved even in the data acquisition. Graphical facilities allow decision upon the data processing flow

  16. Absolute Navigation Information Estimation for Micro Planetary Rovers

    Directory of Open Access Journals (Sweden)

    Muhammad Ilyas

    2016-03-01

    Full Text Available This paper provides algorithms to estimate absolute navigation information, e.g., absolute attitude and position, by using low power, weight and volume Microelectromechanical Systems-type (MEMS sensors that are suitable for micro planetary rovers. Planetary rovers appear to be easily navigable robots due to their extreme slow speed and rotation but, unfortunately, the sensor suites available for terrestrial robots are not always available for planetary rover navigation. This makes them difficult to navigate in a completely unexplored, harsh and complex environment. Whereas the relative attitude and position can be tracked in a similar way as for ground robots, absolute navigation information, unlike in terrestrial applications, is difficult to obtain for a remote celestial body, such as Mars or the Moon. In this paper, an algorithm called the EASI algorithm (Estimation of Attitude using Sun sensor and Inclinometer is presented to estimate the absolute attitude using a MEMS-type sun sensor and inclinometer, only. Moreover, the output of the EASI algorithm is fused with MEMS gyros to produce more accurate and reliable attitude estimates. An absolute position estimation algorithm has also been presented based on these on-board sensors. Experimental results demonstrate the viability of the proposed algorithms and the sensor suite for low-cost and low-weight micro planetary rovers.

  17. Revisiting Dosing Regimen Using Pharmacokinetic/Pharmacodynamic Mathematical Modeling: Densification and Intensification of Combination Cancer Therapy.

    Science.gov (United States)

    Meille, Christophe; Barbolosi, Dominique; Ciccolini, Joseph; Freyer, Gilles; Iliadis, Athanassios

    2016-08-01

    Controlling effects of drugs administered in combination is particularly challenging with a densified regimen because of life-threatening hematological toxicities. We have developed a mathematical model to optimize drug dosing regimens and to redesign the dose intensification-dose escalation process, using densified cycles of combined anticancer drugs. A generic mathematical model was developed to describe the main components of the real process, including pharmacokinetics, safety and efficacy pharmacodynamics, and non-hematological toxicity risk. This model allowed for computing the distribution of the total drug amount of each drug in combination, for each escalation dose level, in order to minimize the average tumor mass for each cycle. This was achieved while complying with absolute neutrophil count clinical constraints and without exceeding a fixed risk of non-hematological dose-limiting toxicity. The innovative part of this work was the development of densifying and intensifying designs in a unified procedure. This model enabled us to determine the appropriate regimen in a pilot phase I/II study in metastatic breast patients for a 2-week-cycle treatment of docetaxel plus epirubicin doublet, and to propose a new dose-ranging process. In addition to the present application, this method can be further used to achieve optimization of any combination therapy, thus improving the efficacy versus toxicity balance of such a regimen.

  18. Measuring the absolute DT neutron yield using the Magnetic Recoil Spectrometer at OMEGA and the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Casey, D; Frenje, J A; Johnson, M G; Seguin, F H; Li, C K; Petrasso, R D; Glebov, V Y; Katz, J; Knauer, J; Meyerhofer, D; Sangster, T; Bionta, R; Bleuel, D; Hachett, S P; Hartouni, E; Lepape, S; Mckernan, M; Moran, M; Yeamans, C

    2012-05-03

    A Magnetic Recoil Spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion (ICF) implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  19. The effects of intra-cerebroventricular administered rocuronium on the central nervous system of rats and determination of its epileptic seizure-inducing dose.

    Science.gov (United States)

    Baykal, Mehmet; Gökmen, Necati; Doğan, Alper; Erbayraktar, Serhat; Yılmaz, Osman; Ocmen, Elvan; Erdost, Hale Aksu; Arkan, Atalay

    The aim of this study was to investigate the effects of intracerebroventricularly administered rocuronium bromide on the central nervous system, determine the seizure threshold dose of rocuronium bromide in rats, and investigate the effects of rocuronium on the central nervous system at 1/5, 1/10, and 1/100 dilutions of the determined seizure threshold dose. A permanent cannula was placed in the lateral cerebral ventricle of the animals. The study was designed in two phases. In the first phase, the seizure threshold dose of rocuronium bromide was determined. In the second phase, Group R 1/5 (n=6), Group 1/10 (n=6), and Group 1/100 (n=6) were formed using doses of 1/5, 1/10, and 1/100, respectively, of the obtained rocuronium bromide seizure threshold dose. The rocuronium bromide seizure threshold value was found to be 0.056±0.009μmoL. The seizure threshold, as a function of the body weight of rats, was calculated as 0.286μmoL/kg -1 . A dose of 1/5 of the seizure threshold dose primarily caused splayed limbs, posturing, and tremors of the entire body, whereas the dose of 1/10 of the seizure threshold dose caused agitation and shivering. A dose of 1/100 of the seizure threshold dose was associated with decreased locomotor activity. This study showed that rocuronium bromide has dose-related deleterious effects on the central nervous system and can produce dose-dependent excitatory effects and seizures. Published by Elsevier Editora Ltda.

  20. [The effects of intra-cerebroventricular administered rocuronium on the central nervous system of rats and determination of its epileptic seizure-inducing dose].

    Science.gov (United States)

    Baykal, Mehmet; Gökmen, Necati; Doğan, Alper; Erbayraktar, Serhat; Yılmaz, Osman; Ocmen, Elvan; Erdost, Hale Aksu; Arkan, Atalay

    The aim of this study was to investigate the effects of intracerebroventricularly administered rocuronium bromide on the central nervous system, determine the seizure threshold dose of rocuronium bromide in rats, and investigate the effects of rocuronium on the central nervous system at 1/5, 1/10, and 1/100 dilutions of the determined seizure threshold dose. A permanent cannula was placed in the lateral cerebral ventricle of the animals. The study was designed in two phases. In the first phase, the seizure threshold dose of rocuronium bromide was determined. In the second phase, Group R 1/5 (n=6), Group 1/10 (n=6), and Group 1/100 (n=6) were formed using doses of 1/5, 1/10, and 1/100, respectively, of the obtained rocuronium bromide seizure threshold dose. The rocuronium bromide seizure threshold value was found to be 0.056±0.009μmoL. The seizure threshold, as a function of the body weight of rats, was calculated as 0.286μmoL/kg -1 . A dose of 1/5 of the seizure threshold dose primarily caused splayed limbs, posturing, and tremors of the entire body, whereas the dose of 1/10 of the seizure threshold dose caused agitation and shivering. A dose of 1/100 of the seizure threshold dose was associated with decreased locomotor activity. This study showed that rocuronium bromide has dose-related deleterious effects on the central nervous system and can produce dose-dependent excitatory effects and seizures. Publicado por Elsevier Editora Ltda.

  1. Determination of internal exposure doses of the personnel of uranium-mining company due to radon isotopes decay products

    International Nuclear Information System (INIS)

    Sevostyanov, V.N.

    2004-01-01

    This work carries out a determination of individual doses of internal exposure of the staff of the uranium-mining company in Kazakhstan due to radon decay products. The company extracts uranium by in-situ leaching. After leaching, uranium is sorbed from a solution in facilities where the staff is located. The state of three uranium mines was analyzed. The dose determination was conducted in tune with the proposed method by using integral alpha-tracking detectors to identify the content of 222 Rn and express appliances to identify the content of radio-active aerosols in air of the working area for determination the equilibrium coefficient. The measurements were performed within one year. The work produced the results in average annual values of radon and thoron decay products activity concentration and variation, equilibrium coefficient variation, and so-called expressive-to-integral value conversion factor. The obtained personnel's individual radiation doses due to radon exposure for this period lie within the range of < 1 mSv/year. (author)

  2. AXAOTHER XL -- A spreadsheet for determining doses for incidents caused by tornadoes or high-velocity straight winds

    International Nuclear Information System (INIS)

    Simpkins, A.A.

    1996-09-01

    AXAOTHER XL is an Excel Spreadsheet used to determine dose to the maximally exposed offsite individual during high-velocity straight winds or tornado conditions. Both individual and population doses may be considered. Potential exposure pathways are inhalation and plume shine. For high-velocity straight winds the spreadsheet has the capability to determine the downwind relative air concentration, however for the tornado conditions, the user must enter the relative air concentration. Theoretical models are discussed and hand calculations are performed to ensure proper application of methodologies. A section has also been included that contains user instructions for the spreadsheet

  3. Absolute-magnitude distributions of supernovae

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, Dean; Wright, John [Department of Physics, Xavier University of Louisiana, New Orleans, LA 70125 (United States); Jenkins III, Robert L. [Applied Physics Department, Richard Stockton College, Galloway, NJ 08205 (United States); Maddox, Larry, E-mail: drichar7@xula.edu [Department of Chemistry and Physics, Southeastern Louisiana University, Hammond, LA 70402 (United States)

    2014-05-01

    The absolute-magnitude distributions of seven supernova (SN) types are presented. The data used here were primarily taken from the Asiago Supernova Catalogue, but were supplemented with additional data. We accounted for both foreground and host-galaxy extinction. A bootstrap method is used to correct the samples for Malmquist bias. Separately, we generate volume-limited samples, restricted to events within 100 Mpc. We find that the superluminous events (M{sub B} < –21) make up only about 0.1% of all SNe in the bias-corrected sample. The subluminous events (M{sub B} > –15) make up about 3%. The normal Ia distribution was the brightest with a mean absolute blue magnitude of –19.25. The IIP distribution was the dimmest at –16.75.

  4. In vitro absolute metabolic quantification by magnetic resonance spectroscopy; Quantificacao metabolica absoluta in vitro por espectroscopia de ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Barreto, Felipe R.; Salmon, Carlos E.G. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica], e-mail: garrido@ffclrp.usp.br

    2010-03-15

    In this project we estimated characteristic nuclear relaxation times (T1 and T2) from {sup 1}H in vitro of water and the following human brain metabolites: N-Acetyl-Aspartate (NAA), Choline (Cho), Creatine (Cr) and Myo-Inositol (M-Ins) using nuclear magnetic resonance spectroscopy, aiming at relaxation effects correction for absolute quantification. Phantoms with 300 mL of a standard solution with a metabolite were used for spectra acquisition. Variable eco time sequences were used to determinate T2 while variable repetition or inversion time was used for T1 determination. Spectra processing was done with MRUI and LCModel software. Origin 8.0 was used for data fitting. The following T1/T2 values (ms) were the best estimated according to calculated absolute concentration analyses: (4061/934) for water, (1800/830) for NAA, (2316/717) for Cr, (2356/1095) for Cho and (1537/531) for M-Ins. With MRUI better results were obtained in T1 and T2 determination for relaxation effects correction in the absolute quantification process. (author)

  5. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  6. Determination of photon conversion factors relating exposure and dose for several extremity phantom designs

    International Nuclear Information System (INIS)

    Roberson, P.L.; Eichner, F.N.; Reece, W.D.

    1986-09-01

    This report presents the results of measurements of dosimetric properties of simple extremity phantoms suitable for use in extremity dosimeter performance testing. Two sizes of phantoms were used in this study. One size represented the forearm or lower leg and the other size represented the finger or toe. For both phantom sizes, measurements were performed on solid plastic phantoms and on phantoms containing simulated bone material to determine the effect of backscattered radiations from the bone on the surface dose. Exposure-to-dose conversion factors (C/sub x/ factors) were determined for photon energies ranging from 16 to 1250 keV (average for 60 Co). The effect of the presence of a phantom was also measured for a 90 Sr/ 90 Y source. Significant differences in the measured C/sub x/ factors were found among the phantoms investigated. The factors for the finger-sized phantoms were uniformly less than for the arm-sized phantoms

  7. Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Gatu Johnson, M; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Knauer, J P; Meyerhofer, D D; Sangster, T C; Bionta, R M; Bleuel, D L; Döppner, T; Glenzer, S; Hartouni, E; Hatchett, S P; Le Pape, S; Ma, T; MacKinnon, A; McKernan, M A; Moran, M; Moses, E; Park, H-S; Ralph, J; Remington, B A; Smalyuk, V; Yeamans, C B; Kline, J; Kyrala, G; Chandler, G A; Leeper, R J; Ruiz, C L; Cooper, G W; Nelson, A J; Fletcher, K; Kilkenny, J; Farrell, M; Jasion, D; Paguio, R

    2012-10-01

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion parameters are determined including the primary DT neutron yield, the ion temperature, and the down-scattered neutron yield. As the MRS detection efficiency is determined from first principles, the absolute DT neutron yield is obtained without cross-calibration to other techniques. The MRS primary DT neutron measurements at OMEGA and the NIF are shown to be in excellent agreement with previously established yield diagnostics on OMEGA, and with the newly commissioned nuclear activation diagnostics on the NIF.

  8. Energy and integrated dose dependence of MOSFET dosimeter for clinical electron beams

    International Nuclear Information System (INIS)

    Manigandan, D.; Bharanidharan, G.; Aruna, P.; Ganesan, S.; Tamil Kumar, T.; Rai

    2008-01-01

    In this study, the sensitivity (mV/cGy) and integral dose dependence of a MOSFET detector for different clinical electron beams was studied. Calibrated clinical electron beams (Varian 2100) were used for the exposure. A Markus type parallel plate chamber was used for the absolute dose measurements. In order to study the sensitivity of a MOSFET, the response of the ion chamber and MOSFET for the absorbed dose of 100 cGy was measured. The sensitivity of the MOSFET was then expressed as mV/cGy. Sensitivity was measured for 4-18 MeV electron beams. (author)

  9. Absolute photoabsorption cross-sections (oscillator strengths) for hydrogen chloride, hydrogen bromide and hydrogen iodide

    International Nuclear Information System (INIS)

    Brion, C.E.; Dyck, M.; Cooper, G.

    2004-01-01

    Full text: Absolute photoabsorption cross-sections (oscillator strengths) for the free molecules HCl, HBr and HI have been measured in the valence and selected in- ner shell regions. The experimental technique used for these studies is dipole (e,e) spectroscopy [1-3] which is not affected by line saturation effects (i.e. bandwidth interactions) which can complicate direct photoabsorption methods using the Beer- Lambert law. The dipole (e,e) method is also not subject to the effects of higher order radiation. In the dipole (e,e) method relative intensities obtained in fast (3 keV) for- ward scattered electron energy loss spectra are converted to relative dipole oscillator strengths (i.e. photoabsorption spectra) using the known Bethe-Born factors for the instrument as a function of photon energy (i.e. energy loss). The target pressure is constant at 10 - 5 torr, but it is not necessary to know the absolute target density. The absolute oscillator strength scale for HCl is determined from Bethe-Born converted, wide range dipole (e,e) spectra using the Thomas-Reiche-Kuhn (TRK) sum rule. For HBr and HI the absolute oscillator strength scales have been established using the S(-2) Sum Rule and literature values of the static dipole polarizability

  10. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Science.gov (United States)

    Brunke, Heinz-Peter; Matzka, Jürgen

    2018-01-01

    At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer). Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination) measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996).We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters) of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017).

  11. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Directory of Open Access Journals (Sweden)

    H.-P. Brunke

    2018-01-01

    Full Text Available At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer. Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996.We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017.

  12. Fieldable computer system for determining gamma-ray pulse-height distributions, flux spectra, and dose rates from Little Boy

    International Nuclear Information System (INIS)

    Moss, C.E.; Lucas, M.C.; Tisinger, E.W.; Hamm, M.E.

    1984-01-01

    Our system consists of a LeCroy 3500 data acquisition system with a built-in CAMAC crate and eight bismuth-germanate detectors 7.62 cm in diameter and 7.62 cm long. Gamma-ray pulse-height distributions are acquired simultaneously for up to eight positions. The system was very carefully calibrated and characterized from 0.1 to 8.3 MeV using gamma-ray spectra from a variety of radioactive sources. By fitting the pulse-height distributions from the sources with a function containing 17 parameters, we determined theoretical repsonse functions. We use these response functions to unfold the distributions to obtain flux spectra. A flux-to-dose-rate conversion curve based on the work of Dimbylow and Francis is then used to obtain dose rates. Direct use of measured spectra and flux-to-dose-rate curves to obtain dose rates avoids the errors that can arise from spectrum dependence in simple gamma-ray dosimeter instruments. We present some gamma-ray doses for the Little Boy assembly operated at low power. These results can be used to determine the exposures of the Hiroshima survivors and thus aid in the establishment of radation exposure limits for the nuclear industry

  13. Dose mapping sensitivity to deformable registration uncertainties in fractionated radiotherapy – applied to prostate proton treatments

    International Nuclear Information System (INIS)

    Tilly, David; Tilly, Nina; Ahnesjö, Anders

    2013-01-01

    Calculation of accumulated dose in fractionated radiotherapy based on spatial mapping of the dose points generally requires deformable image registration (DIR). The accuracy of the accumulated dose thus depends heavily on the DIR quality. This motivates investigations of how the registration uncertainty influences dose planning objectives and treatment outcome predictions. A framework was developed where the dose mapping can be associated with a variable known uncertainty to simulate the DIR uncertainties in a clinical workflow. The framework enabled us to study the dependence of dose planning metrics, and the predicted treatment outcome, on the DIR uncertainty. The additional planning margin needed to compensate for the dose mapping uncertainties can also be determined. We applied the simulation framework to a hypofractionated proton treatment of the prostate using two different scanning beam spot sizes to also study the dose mapping sensitivity to penumbra widths. The planning parameter most sensitive to the DIR uncertainty was found to be the target D 95 . We found that the registration mean absolute error needs to be ≤0.20 cm to obtain an uncertainty better than 3% of the calculated D 95 for intermediate sized penumbras. Use of larger margins in constructing PTV from CTV relaxed the registration uncertainty requirements to the cost of increased dose burdens to the surrounding organs at risk. The DIR uncertainty requirements should be considered in an adaptive radiotherapy workflow since this uncertainty can have significant impact on the accumulated dose. The simulation framework enabled quantification of the accuracy requirement for DIR algorithms to provide satisfactory clinical accuracy in the accumulated dose

  14. Communicating cardiovascular disease risk: an interview study of General Practitioners' use of absolute risk within tailored communication strategies.

    Science.gov (United States)

    Bonner, Carissa; Jansen, Jesse; McKinn, Shannon; Irwig, Les; Doust, Jenny; Glasziou, Paul; McCaffery, Kirsten

    2014-05-29

    Cardiovascular disease (CVD) prevention guidelines encourage assessment of absolute CVD risk - the probability of a CVD event within a fixed time period, based on the most predictive risk factors. However, few General Practitioners (GPs) use absolute CVD risk consistently, and communication difficulties have been identified as a barrier to changing practice. This study aimed to explore GPs' descriptions of their CVD risk communication strategies, including the role of absolute risk. Semi-structured interviews were conducted with a purposive sample of 25 GPs in New South Wales, Australia. Transcribed audio-recordings were thematically coded, using the Framework Analysis method to ensure rigour. GPs used absolute CVD risk within three different communication strategies: 'positive', 'scare tactic', and 'indirect'. A 'positive' strategy, which aimed to reassure and motivate, was used for patients with low risk, determination to change lifestyle, and some concern about CVD risk. Absolute risk was used to show how they could reduce risk. A 'scare tactic' strategy was used for patients with high risk, lack of motivation, and a dismissive attitude. Absolute risk was used to 'scare' them into taking action. An 'indirect' strategy, where CVD risk was not the main focus, was used for patients with low risk but some lifestyle risk factors, high anxiety, high resistance to change, or difficulty understanding probabilities. Non-quantitative absolute risk formats were found to be helpful in these situations. This study demonstrated how GPs use three different communication strategies to address the issue of CVD risk, depending on their perception of patient risk, motivation and anxiety. Absolute risk played a different role within each strategy. Providing GPs with alternative ways of explaining absolute risk, in order to achieve different communication aims, may improve their use of absolute CVD risk assessment in practice.

  15. Planck absolute entropy of a rotating BTZ black hole

    Science.gov (United States)

    Riaz, S. M. Jawwad

    2018-04-01

    In this paper, the Planck absolute entropy and the Bekenstein-Smarr formula of the rotating Banados-Teitelboim-Zanelli (BTZ) black hole are presented via a complex thermodynamical system contributed by its inner and outer horizons. The redefined entropy approaches zero as the temperature of the rotating BTZ black hole tends to absolute zero, satisfying the Nernst formulation of a black hole. Hence, it can be regarded as the Planck absolute entropy of the rotating BTZ black hole.

  16. Absolute nuclear material assay using count distribution (LAMBDA) space

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2012-06-05

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  17. SU-G-201-06: Directional Low-Dose Rate Brachytherapy: Determination of the TG-43 Dose-Rate Constant Analog for a New Pd-103 Source

    Energy Technology Data Exchange (ETDEWEB)

    Aima, M; Culberson, W; Hammer, C; Micka, J; DeWerd, L [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI (United States)

    2016-06-15

    Purpose: The aim of this work is to determine the TG-43 dose-rate constant analog for a new directional low-dose rate brachytherapy source based on experimental methods and comparison to Monte Carlo simulations. The CivaSheet™ is a new commercially available planar source array comprised of a variable number of discrete directional source elements called “CivaDots”. Given the directional nature and non-conventional design of the source, modifications to the AAPM TG-43 protocol for dosimetry are required. As a result, various parameters of the TG-43 dosimetric formalism have to be adapted to accommodate this source. This work focuses on the dose-rate constant analog determination for a CivaDot. Methods: Dose to water measurements of the CivaDot were performed in a polymethyl methacrylate phantom (20×20×12 cm{sup 3}) using thermoluminescent dosimeters (TLDs) and Gafchromic EBT3 film. The source was placed in the center of the phantom, and nine TLD micro-cubes were irradiated along its central axis at a distance of 1 cm. For the film measurements, the TLDs were substituted by a (3×3) cm{sup 2} EBT3 film. Primary air-kerma strength measurements of the source were performed using a variable-aperture free-air chamber. Finally, the source was modeled using the Monte Carlo N-Particle Transport Code 6. Results: Dose-rate constant analog observed for a total of eight CivaDots using TLDs and five CivaDots using EBT3 film was within ±7.0% and ±2.9% of the Monte Carlo predicted value respectively. The average difference observed was −4.8% and −0.1% with a standard deviation of 1.7% and 2.1% for the TLD and the film measurements respectively, which are both within the comparison uncertainty. Conclusion: A preliminary investigation to determine the doserate constant analog for a CivaDot was conducted successfully with good agreement between experimental and Monte Carlo based methods. This work will aid in the eventual realization of a clinically-viable dosimetric

  18. Evaluation of six TPS algorithms in computing entrance and exit doses

    Science.gov (United States)

    Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun P.; Elliott, Alex

    2014-01-01

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%‐3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.N‐, 87.53.Bn PMID:24892349

  19. Validation of GPU based TomoTherapy dose calculation engine.

    Science.gov (United States)

    Chen, Quan; Lu, Weiguo; Chen, Yu; Chen, Mingli; Henderson, Douglas; Sterpin, Edmond

    2012-04-01

    The graphic processing unit (GPU) based TomoTherapy convolution/superposition(C/S) dose engine (GPU dose engine) achieves a dramatic performance improvement over the traditional CPU-cluster based TomoTherapy dose engine (CPU dose engine). Besides the architecture difference between the GPU and CPU, there are several algorithm changes from the CPU dose engine to the GPU dose engine. These changes made the GPU dose slightly different from the CPU-cluster dose. In order for the commercial release of the GPU dose engine, its accuracy has to be validated. Thirty eight TomoTherapy phantom plans and 19 patient plans were calculated with both dose engines to evaluate the equivalency between the two dose engines. Gamma indices (Γ) were used for the equivalency evaluation. The GPU dose was further verified with the absolute point dose measurement with ion chamber and film measurements for phantom plans. Monte Carlo calculation was used as a reference for both dose engines in the accuracy evaluation in heterogeneous phantom and actual patients. The GPU dose engine showed excellent agreement with the current CPU dose engine. The majority of cases had over 99.99% of voxels with Γ(1%, 1 mm) engine also showed similar degree of accuracy in heterogeneous media as the current TomoTherapy dose engine. It is verified and validated that the ultrafast TomoTherapy GPU dose engine can safely replace the existing TomoTherapy cluster based dose engine without degradation in dose accuracy.

  20. Dose patient verification during treatment using an amorphous silicon electronic portal imaging device in radiotherapy

    International Nuclear Information System (INIS)

    Berger, Lucie

    2006-01-01

    Today, amorphous silicon electronic portal imaging devices (aSi EPID) are currently used to check the accuracy of patient positioning. However, they are not use for dose reconstruction yet and more investigations are required to allow the use of an aSi EPID for routine dosimetric verification. The aim of this work is first to study the dosimetric characteristics of the EPID available at the Institut Curie and then, to check patient dose during treatment using these EPID. First, performance optimization of the Varian aS500 EPID system is studied. Then, a quality assurance system is set up in order to certify the image quality on a daily basis. An additional study on the dosimetric performance of the aS500 EPID is monitored to assess operational stability for dosimetry applications. Electronic portal imaging device is also a useful tool to improve IMRT quality control. The validation and the quality assurance of a portal dose image prediction system for IMRT pre-treatment quality control are performed. All dynamic IMRT fields are verified in clinical routine with the new method based on portal dosimetry. Finally, a new formalism for in vivo dosimetry using transit dose measured with EPID is developed and validated. The absolute dose measurement issue using aSi EPID is described and the midplane dose determination using in vivo dose measurements in combination with portal imaging is used with 3D-conformal-radiation therapy. (author) [fr

  1. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  2. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2010-02-15

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd

  3. Absorbed dose determination in photon fields using the tandem method

    International Nuclear Information System (INIS)

    Marques Pachas, J.F.

    1999-01-01

    The purpose of this work is to develop an alternative method to determine the absorbed dose and effective energy of photons with unknown spectral distributions. It includes a 'tandem' system that consists of two thermoluminescent dosemeters with different energetic dependence. LiF: Mg, Ti, CaF 2 : Dy thermoluminescent dosemeters and a Harshaw 3500 reading system are employed. Dosemeters are characterized with 90 Sr- 90 Y, calibrated with the energy of 60 Co and irradiated with seven different qualities of x-ray beams, suggested by ANSI No. 13 and ISO 4037. The answers of each type of dosemeter are adjusted to a function that depends on the effective energy of photons. The adjustment is carried out by means of the Rosenbrock minimization algorithm. The mathematical model used for this function includes five parameters and has a gauss and a straight line. Results show that the analytical functions reproduce the experimental data of the answers, with a margin of error of less than 5%. The reason of the answers of the CaF 2 : Dy and LiF: Mg, Ti, according to the energy of the radiation, allows us to establish the effective energy of photons and the absorbed dose, with a margin of error of less than 10% and 20% respectively

  4. Determination of gonad, eye and bone marrow doses with EMI-5005 head and whole body scans

    International Nuclear Information System (INIS)

    Nishizawa, Kanae; Iwata, Takeo; Furuya, Yoshiro; Maruyama, Takashi; Hashizume, Tadashi.

    1979-01-01

    Dose determinations of tissues and organs during head and whole body scanning with an EMI computed tomographic equipment have been carried out using a Rando woman phantom. The surface dose on the phantom was measured with a Sakura lith Contact film dosimeter system. The absorbed doses in the eyes, thyroids, ovaries and the bone marrow were measured with a thermoluminescent dosimeter. The resultant surface doses for head scanning were 2.8 rad (28 mGy) per scan at maximum and 0.26 rad (2.6 mGy) per scan at minimum, and the doses for whole body scanning were 2.7 rad (27 mGy) per scan at maximum and 0.1 rad (1.0 mGy) per scan at minimum. For the complete gynecological scanning consisting of 8 slices, the eye, thyroid, ovary and the bone marrow dose was 2.4 mrad (24 μGy), 3.5 mrad (35 μGy), 500 mrad (5 mGy) and 225 mrad (2.25 mGy), respectively. And, for a typical head scanning consisting of 5 slices, the eye, thyroid, ovary and the bone marrow dose was 1400 mrad (14 mGy), 46 mrad (460 μGy), 0.60 mrad (6 μGy) and 73 mrad (730 μGy), respectively. (author)

  5. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  6. Central-to-axial chirality transfer revealed by liquid crystals: a combined experimental and computational approach for the determination of absolute configuration of carboxylic acids with an α chirality centre.

    Science.gov (United States)

    Ferrarini, Alberta; Ferroni, Fiammetta; Pieraccini, Silvia; Rosini, Carlo; Superchi, Stefano; Spada, Gian Piero

    2011-10-01

    The conversion into 6,7-dihydro-5H-dibenz[c,e]azepine (DAZ) N-protected amides is a viable route for the determination of the absolute configuration of chiral 2-substituted carboxylic acids. The biphenyl moiety of DAZ, besides being a probe of chirality for the electronic circular dichroism (ECD) spectroscopy, makes these systems suitable for configuration assignment by exploiting the chirality amplification which occurs in nematic liquid crystals. To assess the reliability of the liquid crystal method in detecting the absolute stereochemistry of chiral amides bound to a biphenyl group, we measured the helical twisting power of a series of DAZ-N-protected amides and compared these data with the results obtained from ECD measurements. We will show that the liquid crystal method, corroborated by HTP predictions, is trustworthy with our biphenyl derivatives, even when ECD spectra are ambiguous for the presence of aryl moieties displaying strong UV absorptions in the same range of the biphenyl chromophore. © 2011 Wiley-Liss, Inc.

  7. Decimal reduction dose (D10) and optimal dose determination to eliminate salmonella typhimurium in chicken hamburgers through 60Co gamma radiation

    International Nuclear Information System (INIS)

    Basurto B, H.M.

    2001-01-01

    Under aerobic conditions and at room temperature, decimal reduction dose (D 10 ) of S. typhimurium in casoy broth (TSB) was determined through irradiation, inoculating 9,78 log ufc/mL of a strain during 24±2 hours and obtaining a D 10 of 0,425 kGy. Next, the D 10 value of S. typhimurium inoculated in chicken hamburger with a 9,3 log ufc/g concentration was determined under the same conditions of the previous case, obtaining a D 10 of 0,547 kGy, 22,3% higher than the first value. Then, hamburgers were irradiated at 2, 4 and 6 kGy and kept under storage for 57 days at 2±2 o C. During evaluations, it was observed that there is a synergic effect between the irradiation dose and the time of storage (α=5%) for S. typhimurium inoculated in hamburgers. Besides, in the case of the non-irradiated samples, the number of total coliforms increased from 29 to 4250 NMP/g in day 22, while fecal coliforms increased from 4 to 240 NMP/g during the same period, dropping at the end of storage. In the case of irradiated samples, no coliforms were found (<3 NMP/g). Mesofilic and psicrotrofic bacteria diminished their ability to form colonies proportionally to the applied irradiation doses. Nevertheless, as storage time goes by, these bacteria recover the ability to grow up and cause deterioration. Peroxide rate values of irradiated samples were 100% higher than those of the non-irradiated samples. However, there was no significant difference between samples treated at 2,4 and 6 kGy. Finally, useful life of hamburgers was determined through sensorial evaluation of characteristics such as color, external appearance and smell of raw hamburgers, and taste, smell and texture of fried hamburgers. The results obtained were 13, 19, 41 and 34 days for non-irradiated samples, at 2, 4, and 6 kGy respectively

  8. On the absolute photoionization cross section and dissociative photoionization of cyclopropenylidene.

    Science.gov (United States)

    Holzmeier, Fabian; Fischer, Ingo; Kiendl, Benjamin; Krueger, Anke; Bodi, Andras; Hemberger, Patrick

    2016-04-07

    We report the determination of the absolute photoionization cross section of cyclopropenylidene, c-C3H2, and the heat of formation of the C3H radical and ion derived by the dissociative ionization of the carbene. Vacuum ultraviolet (VUV) synchrotron radiation as provided by the Swiss Light Source and imaging photoelectron photoion coincidence (iPEPICO) were employed. Cyclopropenylidene was generated by pyrolysis of a quadricyclane precursor in a 1 : 1 ratio with benzene, which enabled us to derive the carbene's near threshold absolute photoionization cross section from the photoionization yield of the two pyrolysis products and the known cross section of benzene. The cross section at 9.5 eV, for example, was determined to be 4.5 ± 1.4 Mb. Upon dissociative ionization the carbene decomposes by hydrogen atom loss to the linear isomer of C3H(+). The appearance energy for this process was determined to be AE(0K)(c-C3H2; l-C3H(+)) = 13.67 ± 0.10 eV. The heat of formation of neutral and cationic C3H was derived from this value via a thermochemical cycle as Δ(f)H(0K)(C3H) = 725 ± 25 kJ mol(-1) and Δ(f)H(0K)(C3H(+)) = 1604 ± 19 kJ mol(-1), using a previously reported ionization energy of C3H.

  9. Determination of uranium in soil with emphasis on dose assessment

    International Nuclear Information System (INIS)

    Vidic, A.; Ilic, Z.; Deljkic, D.; Repinc, U.; Benedik, Lj.; Maric, S.

    2005-01-01

    Uranium is present naturally in the earth crust and has three isotopes with long half-lives. These isotopes are 2 38U (99.27% natural abundance), 2 35U (0.72% natural abundance) and 2 34U (0.006% natural abundance). Isotope 2 35U is a valuable fuel for nuclear power plants. During the manufacture of nuclear fuel the concentration of 2 35U is increased. Depleted uranium (DU) is a waste product of this enrichment process and typically contains about 99.8% 2 38U , 0.2% 2 35U and 0.0006% 2 34U in mass. Due to its high density and other physical properties, DU is used in munitions designed to penetrate armour plate. DU weapons were used during the Balkan war in Bosnia and Herzegovina. It was estimated, that nearly 10,000 projectiles were fired or 3 tonnes of DU used in BandH. The aim of this work was to determine uranium radioisotopes in soil and air collected in Hadzici (near Sarajevo). The investigated area is a former military base used for the production and maintenance of tanks and other heavy military vehicles. During a NATO attack in 1995, about 1,500 rounds were fired at the site. The specific activities of 2 38U found in soil ranged from 28 Bq/kg to 55 Bq/kg. We found higher specific activities in some foci, in the range from 143 Bq/kg to 810 Bq/kg. The specific activities of uranium isotopes in the air were determined using simple dust loading approach. The results served to calculate the annual effective dose that could be received by individual workers at the site and by general population from the surrounding area. Radioactivity measurements in the environment of Hadzici showed that the annual effective dose for general population was less than 20 micro Sv.(author)

  10. Synchronous absolute EIT in three thoracic planes at different gravity levels

    International Nuclear Information System (INIS)

    Hahn, G; Just, A; Dittmar, J; Fromm, K H; Quintel, M

    2013-01-01

    The validity of absolute Electrical Impedance Tomography (a-EIT) for assessment of local lung volume has been investigated far less than the well evaluated ventilation monitoring by functional EIT (f-EIT). To achieve progress in a-EIT we investigated 10 healthy volunteers in an upright sitting position by using a-EIT at normal gravity (1 g), weightlessness (0 g) and approx. double gravity (1.8 g) during parabolic flight manoeuvres. Lung resistivity in three thoracic planes was determined by a-EIT using a multiple-plane synchronised Goe-MF II EIT system. Tomograms of resistivity at end-expiration in normal spontaneous breathing were reconstructed by a modified SIRT algorithm. Local lung resistivity was determined separately for both lungs. The respective resistivity values at 1 g and 1.8 g before and after weightlessness show an almost reversible behaviour along the sequence of gravity changes with a tendency to be lower after occurrence of weightlessness. The results reveal not only the expected varying resistivity of lung tissue in cranio-caudal direction but also a clear difference in these cranio-caudal stratifications of local lung volume between the left and right lung. The resolution and stability of absolute EIT seem to be valid and expressive for future investigations of unilateral lung volume under different physiological and pathological conditions.

  11. Enantiomeric Mixtures in Natural Product Chemistry: Separation and Absolute Configuration Assignment.

    Science.gov (United States)

    N L Batista, Andrea; M Dos Santos, Fernando; Batista, João M; Cass, Quezia B

    2018-02-23

    Chiral natural product molecules are generally assumed to be biosynthesized in an enantiomerically pure or enriched fashion. Nevertheless, a significant amount of racemates or enantiomerically enriched mixtures has been reported from natural sources. This number is estimated to be even larger since the enantiomeric purity of secondary metabolites is rarely checked in the natural product isolation pipeline. This latter fact may have drastic effects on the evaluation of the biological activity of chiral natural products. A second bottleneck is the determination of their absolute configurations. Despite the widespread use of optical rotation and electronic circular dichroism, most of the stereochemical assignments are based on empirical correlations with similar compounds reported in the literature. As an alternative, the combination of vibrational circular dichroism and quantum chemical calculations has emerged as a powerful and reliable tool for both conformational and configurational analysis of natural products, even for those lacking UV-Vis chromophores. In this review, we aim to provide the reader with a critical overview of the occurrence of enantiomeric mixtures of secondary metabolites in nature as well the best practices for their detection, enantioselective separation using liquid chromatography, and determination of absolute configuration by means of vibrational circular dichroism and density functional theory calculations.

  12. Passive Dosing to Determine the Speciation of Hydrophobic Organic Chemicals in Aqueous Samples

    DEFF Research Database (Denmark)

    Birch, Heidi; Gouliarmou, V.; Lützhøft, Hans-Christian Holten

    2010-01-01

    A new analytical approach to determine the speciation of hydrophobic organic analytes is presented. The freely dissolved concentration in a sample is controlled by passive dosing from silicone (poly(dimethylsiloxane)), and the total sample concentration at equilibrium is measured. The free fraction...... is determined as the ratio between measured concentrations in pure water and sample. C-14-labeled fluoranthene served as model analyte, and total sample concentrations were easily measured by liquid scintillation counting. The method was applied to surface water, stormwater runoff, and wastewater...... (SPME). This analytical approach combines simplicity with high precision, and it does not require any phase separation steps....

  13. SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Gersh, J [Gibbs Cancer Center & Research Institute - Pelham, Greer, SC (United States); Spectrum Medical Physics, LLC - Greenville, SC (United States); Willett, B [Accuray, Inc., Sunnyvale, CA (United States)

    2015-06-15

    Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC method introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

  14. The optimal fraction size in high-dose-rate brachytherapy: dependency on tissue repair kinetics and low-dose rate

    International Nuclear Information System (INIS)

    Sminia, Peter; Schneider, Christoph J.; Fowler, Jack F.

    2002-01-01

    Background and Purpose: Indications of the existence of long repair half-times on the order of 2-4 h for late-responding human normal tissues have been obtained from continuous hyperfractionated accelerated radiotherapy (CHART). Recently, these data were used to explain, on the basis of the biologically effective dose (BED), the potential superiority of fractionated high-dose rate (HDR) with large fraction sizes of 5-7 Gy over continuous low-dose rate (LDR) irradiation at 0.5 Gy/h in cervical carcinoma. We investigated the optimal fraction size in HDR brachytherapy and its dependency on treatment choices (overall treatment time, number of HDR fractions, and time interval between fractions) and treatment conditions (reference low-dose rate, tissue repair characteristics). Methods and Materials: Radiobiologic model calculations were performed using the linear-quadratic model for incomplete mono-exponential repair. An irradiation dose of 20 Gy was assumed to be applied either with HDR in 2-12 fractions or continuously with LDR for a range of dose rates. HDR and LDR treatment regimens were compared on the basis of the BED and BED ratio of normal tissue and tumor, assuming repair half-times between 1 h and 4 h. Results: With the assumption that the repair half-time of normal tissue was three times longer than that of the tumor, hypofractionation in HDR relative to LDR could result in relative normal tissue sparing if the optimum fraction size is selected. By dose reduction while keeping the tumor BED constant, absolute normal tissue sparing might therefore be achieved. This optimum HDR fraction size was found to be largely dependent on the LDR dose rate. On the basis of the BED NT/TUM ratio of HDR over LDR, 3 x 6.7 Gy would be the optimal HDR fractionation scheme for replacement of an LDR scheme of 20 Gy in 10-30 h (dose rate 2-0.67 Gy/h), while at a lower dose rate of 0.5 Gy/h, four fractions of 5 Gy would be preferential, still assuming large differences between tumor

  15. Determination of the delivered hemodialysis dose using standard methods and on-line clearance monitoring

    Directory of Open Access Journals (Sweden)

    Vlatković Vlastimir

    2006-01-01

    Full Text Available Background/aim: Delivered dialysis dose has a cumulative effect and significant influence upon the adequacy of dialysis, quality of life and development of co-morbidity at patients on dialysis. Thus, a great attention is given to the optimization of dialysis treatment. On-line Clearance Monitoring (OCM allows a precise and continuous measurement of the delivered dialysis dose. Kt/V index (K = dialyzer clearance of urea; t = dialysis time; V = patient's total body water, measured in real time is used as a unit for expressing the dialysis dose. The aim of this research was to perform a comparative assessment of the delivered dialysis dose by the application of the standard measurement methods and a module for continuous clearance monitoring. Methods. The study encompassed 105 patients who had been on the chronic hemodialysis program for more than three months, three times a week. By random choice, one treatment per each controlled patient was taken. All the treatments understood bicarbonate dialysis. The delivered dialysis dose was determined by the calculation of mathematical models: Urea Reduction Ratio (URR singlepool index Kt/V (spKt/V and by the application of OCM. Results. Urea Reduction Ratio was the most sensitive parameter for the assessment and, at the same time, it was in the strongest correlation with the other two, spKt/V indexes and OCM. The values pointed out an adequate dialysis dose. The URR values were significantly higher in women than in men, p < 0.05. The other applied model for the delivered dialysis dose measurement was Kt/V index. The obtained values showed that the dialysis dose was adequate, and that, according to this parameter, the women had significantly better dialysis, then the men p < 0.05. According to the OCM, the average value was slightly lower than the adequate one. The women had a satisfactory dialysis according to this index as well, while the delivered dialysis dose was insufficient in men. The difference

  16. Approach to Absolute Zero

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 10. Approach to Absolute Zero Below 10 milli-Kelvin. R Srinivasan. Series Article Volume 2 Issue 10 October 1997 pp 8-16. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/10/0008-0016 ...

  17. Single dose pharmacokinetics of fenspiride hydrochloride: phase I clinical trial.

    Science.gov (United States)

    Montes, B; Catalan, M; Roces, A; Jeanniot, J P; Honorato, J M

    1993-01-01

    The absolute bioavailability of fenspiride has been studied in twelve healthy volunteers. It was administered IV and orally in single doses of 80 mg fenspiride hydrochloride according to a randomised crossover pattern. Following IV administration, the plasma clearance of fenspiride was about 184 ml.min-1, and its apparent volume of distribution was moderately large (215 l). When given orally as a tablet, fenspiride exhibited fairly slow ab- sorption; the maximum plasma concentration (206 ng.ml-1) was achieved 6 h after administration. The absolute bioavailability was almost complete (90%). The tablet had slow release characteristics. The elimination half-life obtained from the plasma data was 14 to 16 h independent of the route of administration.

  18. Absolute Configuration from Different Multifragmentation Pathways in Light-Induced Coulomb Explosion Imaging.

    Science.gov (United States)

    Pitzer, Martin; Kastirke, Gregor; Kunitski, Maksim; Jahnke, Till; Bauer, Tobias; Goihl, Christoph; Trinter, Florian; Schober, Carl; Henrichs, Kevin; Becht, Jasper; Zeller, Stefan; Gassert, Helena; Waitz, Markus; Kuhlins, Andreas; Sann, Hendrik; Sturm, Felix; Wiegandt, Florian; Wallauer, Robert; Schmidt, Lothar Ph H; Johnson, Allan S; Mazenauer, Manuel; Spenger, Benjamin; Marquardt, Sabrina; Marquardt, Sebastian; Schmidt-Böcking, Horst; Stohner, Jürgen; Dörner, Reinhard; Schöffler, Markus; Berger, Robert

    2016-08-18

    The absolute configuration of individual small molecules in the gas phase can be determined directly by light-induced Coulomb explosion imaging (CEI). Herein, this approach is demonstrated for ionization with a single X-ray photon from a synchrotron light source, leading to enhanced efficiency and faster fragmentation as compared to previous experiments with a femtosecond laser. In addition, it is shown that even incomplete fragmentation pathways of individual molecules from a racemic CHBrClF sample can give access to the absolute configuration in CEI. This leads to a significant increase of the applicability of the method as compared to the previously reported complete break-up into atomic ions and can pave the way for routine stereochemical analysis of larger chiral molecules by light-induced CEI. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Population-based absolute risk estimation with survey data

    Science.gov (United States)

    Kovalchik, Stephanie A.; Pfeiffer, Ruth M.

    2013-01-01

    Absolute risk is the probability that a cause-specific event occurs in a given time interval in the presence of competing events. We present methods to estimate population-based absolute risk from a complex survey cohort that can accommodate multiple exposure-specific competing risks. The hazard function for each event type consists of an individualized relative risk multiplied by a baseline hazard function, which is modeled nonparametrically or parametrically with a piecewise exponential model. An influence method is used to derive a Taylor-linearized variance estimate for the absolute risk estimates. We introduce novel measures of the cause-specific influences that can guide modeling choices for the competing event components of the model. To illustrate our methodology, we build and validate cause-specific absolute risk models for cardiovascular and cancer deaths using data from the National Health and Nutrition Examination Survey. Our applications demonstrate the usefulness of survey-based risk prediction models for predicting health outcomes and quantifying the potential impact of disease prevention programs at the population level. PMID:23686614

  20. Absolute marine gravimetry with matter-wave interferometry.

    Science.gov (United States)

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.