WorldWideScience

Sample records for aberration-free refractive surgery

  1. Study on the transverse chromatic aberration of the individual eye model after LASIK refractive surgery

    Science.gov (United States)

    Zhang, Mei; Wang, Zhao-Qi; Wang, Yan; Zuo, Tong

    2010-10-01

    The aim of this research is to study the properties of the transverse chromatic aberration (TCA) after the LASIK refractive surgery based on the individual eye model involving the angle between visual axis and optical axis. According to the measurements of the corneal surfaces, the optical axis lengths and the wavefront aberrations, the individual eye models before and after LASIK refractive surgery are constructed for 15 eyes by using ZEMAX optic design software, while the angle between the visual axis and optical axis is calculated from the data of the anterior corneal surface. The constructed eye models are then used to investigate the variation of the TCA after the surgery. The statistical distributions of the magnitude of the foveal TCA for 15 eyes over the visible spectrum are provided. Finally, we investigate the influence of the TCA on the visual quality and compare the results with previous research. The TCA is an indispensable criterion to evaluate the performance of the refractive surgery. This research is very meaningful for the studies of not only foveal vision but also the peripheral vision.

  2. Assessment of refractive astigmatism and simulated therapeutic refractive surgery strategies in coma-like-aberrations-dominant corneal optics.

    Science.gov (United States)

    Zhou, Wen; Stojanovic, Aleksandar; Utheim, Tor Paaske

    2016-01-01

    The aim of the study is to raise the awareness of the influence of coma-like higher-order aberrations (HOAs) on power and orientation of refractive astigmatism (RA) and to explore how to account for that influence in the planning of topography-guided refractive surgery in eyes with coma-like-aberrations-dominant corneal optics. Eleven eyes with coma-like-aberrations-dominant corneal optics and with low lenticular astigmatism (LA) were selected for astigmatism analysis and for treatment simulations with topography-guided custom ablation. Vector analysis was used to evaluate the contribution of coma-like corneal HOAs to RA. Two different strategies were used for simulated treatments aiming to regularize irregular corneal optics: With both strategies correction of anterior corneal surface irregularities (corneal HOAs) were intended. Correction of total corneal astigmatism (TCA) and RA was intended as well with strategies 1 and 2, respectively. Axis of discrepant astigmatism (RA minus TCA minus LA) correlated strongly with axis of coma. Vertical coma influenced RA by canceling the effect of the with-the-rule astigmatism and increasing the effect of the against-the-rule astigmatism. After simulated correction of anterior corneal HOAs along with TCA and RA (strategies 1 and 2), only a small amount of anterior corneal astigmatism (ACA) and no TCA remained after strategy 1, while considerable amount of ACA and TCA remained after strategy 2. Coma-like corneal aberrations seem to contribute a considerable astigmatic component to RA in eyes with coma-like-aberrations dominant corneal optics. If topography-guided ablation is programmed to correct the corneal HOAs and RA, the astigmatic component caused by the coma-like corneal HOAs will be treated twice and will result in induced astigmatism. Disregarding RA and treating TCA along with the corneal HOAs is recommended instead.

  3. Retrospective Analysis of the Post-Operative Changes in Higher-Order Aberrations: A Comparison of the WaveLight EX500 to the VISX S4 Laser in Refractive Surgery.

    Science.gov (United States)

    Reed, Donovan S; Apsey, Douglas; Steigleman, Walter; Townley, James; Caldwell, Matthew

    2017-11-01

    In an attempt to maximize treatment outcomes, refractive surgery techniques are being directed toward customized ablations to correct not only lower-order aberrations but also higher-order aberrations specific to the individual eye. Measurement of the entirety of ocular aberrations is the most definitive means to establish the true effect of refractive surgery on image quality and visual performance. Whether or not there is a statistically significant difference in induced higher-order corneal aberrations between the VISX Star S4 (Abbott Medical Optics, Santa Ana, California) and the WaveLight EX500 (Alcon, Fort Worth, Texas) lasers was examined. A retrospective analysis was performed to investigate the difference in root-mean-square (RMS) value of the higher-order corneal aberrations postoperatively between two currently available laser platforms, the VISX Star S4 and the WaveLight EX500 lasers. The RMS is a compilation of higher-order corneal aberrations. Data from 240 total eyes of active duty military or Department of Defense beneficiaries who completed photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK) refractive surgery at the Wilford Hall Ambulatory Surgical Center Joint Warfighter Refractive Surgery Center were examined. Using SPSS statistics software (IBM Corp., Armonk, New York), the mean changes in RMS values between the two lasers and refractive surgery procedures were determined. A Student t test was performed to compare the RMS of the higher-order aberrations of the subjects' corneas from the lasers being studied. A regression analysis was performed to adjust for preoperative spherical equivalent. The study and a waiver of informed consent have been approved by the Clinical Research Division of the 59th Medical Wing Institutional Review Board (Protocol Number: 20150093H). The mean change in RMS value for PRK using the VISX laser was 0.00122, with a standard deviation of 0.02583. The mean change in RMS value for PRK using the

  4. Aberration-free intraocular lenses - What does this really mean?

    Science.gov (United States)

    Langenbucher, Achim; Schröder, Simon; Cayless, Alan; Eppig, Timo

    2017-09-01

    So-called aberration-free intraocular lenses (IOLs) are well established in modern cataract surgery. Usually, they are designed to perfectly refract a collimated light beam onto the focal point. We show how much aberration can be expected with such an IOL in a convergent light beam such as that found anterior to the human cornea. Additionally, the aberration in a collimated beam is estimated for an IOL that has no aberrations in the convergent beam. The convergent beam is modelled as the pencil of rays corresponding to the spherical wavefront resulting from a typical corneal power of 43m -1 . The IOLs are modelled as infinitely thin phase plates with 20m -1 optical power placed 5mm behind the cornea. Their aberrations are reported in terms of optical path length difference and longitudinal spherical aberration (LSA) of the marginal rays, as well as nominal spherical aberration (SA) calculated based on a Zernike representation of the wavefront-error at the corneal plane within a 6mm aperture. The IOL designed to have no aberrations in a collimated light beam has an optical path length difference of -1.8μm, and LSA of 0.15m -1 in the convergent beam of a typical eye. The corresponding nominal SA is 0.065μm. The IOL designed to have no aberrations in a convergent light beam has an optical path length difference of 1.8μm, and LSA of -0.15m -1 in the collimated beam. An IOL designed to have no aberrations in a collimated light beam will increase the SA of a patient's eye after implantation. Copyright © 2017. Published by Elsevier GmbH.

  5. Related research on corneal higher-order aberrations after different ways refractive surgery

    Directory of Open Access Journals (Sweden)

    Shu-Xi He

    2015-08-01

    Full Text Available AIM:To evaluate the changes of corneal high-order aberration(including Coma, Spab, RMShafter laser in situ keratomileusis(LASIKwith femtosecond laser, sub-Bowman keratomileusis(SBKand laser epithelial keratomileusis(LASEK.METHODS: Of 82 myopic patients(164 eyes, 31 patients(62 eyeswere treated by FS-LASIK, 31 patients(62 eyeswere treated by SBK, 20 patients(40 eyeswere treated by LASEK. Sirius system was used for measuring the coma aberration, spherical aberration, and high order aberration at 1, 15d,1, 3mo after surgery.RESULTS: 1Vision: The uncorrected visual acuity of the three groups had no differences(P>0.05. 2Corneal aberrations: Three kinds of surgical procedure for patients with corneal aberration had significant impact. The C7, C8, C12 and RMSh of three groups were increased significantly(P0.05. The C7, C8, C12 and RMSh were not recovered to preoperative levels after 3mo. But the increase of patients after FS-LASIK was smaller than the other two groups, with statistical significance(P0.05.CONCLUSION: Compared with SBK and LASEK,FS-LASIK has better visual acuity in the early postoperative and corneal higher-order aberrations increase is relatively small.

  6. Refractive and diffractive neutron optics with reduced chromatic aberration

    DEFF Research Database (Denmark)

    Poulsen, Stefan Othmar; Poulsen, Henning Friis; Bentley, P.M.

    2014-01-01

    by the use of optics for focusing and imaging. Refractive and diffractive optical elements, e.g. compound refractive lenses and Fresnel zone plates, are attractive due to their low cost, and simple alignment. These optical elements, however, suffer from chromatic aberration, which limit their effectiveness...

  7. Ocular wavefront aberration and refractive error in pre-school children

    Science.gov (United States)

    Thapa, Damber; Fleck, Andre; Lakshminarayanan, Vasudevan; Bobier, William R.

    2011-11-01

    Hartmann-Shack images taken from an archived collection of SureSight refractive measurements of pre-school children in Oxford County, Ontario, Canada were retrieved and re-analyzed. Higher-order aberrations were calculated over the age range of 3 to 6 years. These higher-order aberrations were compared with respect to magnitudes of ametropia. Subjects were classified as emmetropic (range -0.5 to + 0.5D), low hyperopic (+ 0.5 to +2D) and high hyperopic (+2D or more) based upon the resulting spherical equivalent. Higher-order aberrations were found to increase with higher levels of hyperopia (p < 0.01). The strongest effect was for children showing more than +2.00D of hyperopia. The correlation coefficients were small in all of the higher-order aberrations; however, they were significant (p < 0.01). These analyses indicate a weak association between refractive error and higher-order aberrations in pre-school children.

  8. Questionnaires for Measuring Refractive Surgery Outcomes.

    Science.gov (United States)

    Kandel, Himal; Khadka, Jyoti; Lundström, Mats; Goggin, Michael; Pesudovs, Konrad

    2017-06-01

    To identify the questionnaires used to assess refractive surgery outcomes, assess the available questionnaires in regard to their psychometric properties, validity, and reliability, and evaluate the performance of the available questionnaires in measuring refractive surgery outcomes. An extensive literature search was done on PubMed, MEDLINE, Scopus, CINAHL, Cochrane, and Web of Science databases to identify articles that described or used at least one questionnaire to assess refractive surgery outcomes. The information on content quality, validity, reliability, responsiveness, and psychometric properties was extracted and analyzed based on an extensive set of quality criteria. Eighty-one articles describing 27 questionnaires (12 refractive error-specific, including 4 refractive surgery-specific, 7 vision-but-non-refractive, and 8 generic) were included in the review. Most articles (56, 69.1%) described refractive error-specific questionnaires. The Quality of Life Impact of Refractive Correction (QIRC), the Quality of Vision (QoV), and the Near Activity Visual Questionnaire (NAVQ) were originally constructed using Rasch analysis; others were developed using the Classical Test Theory. The National Eye Institute Refractive Quality of Life questionnaire was the most frequently used questionnaire, but it does not provide a valid measurement. The QoV, QIRC, and NAVQ are the three best existing questionnaires to assess visual symptoms, quality of life, and activity limitations, respectively. This review identified three superior quality questionnaires for measuring different aspects of quality of life in refractive surgery. Clinicians and researchers should choose a questionnaire based on the concept being measured with superior psychometric properties. [J Refract Surg. 2017;33(6):416-424.]. Copyright 2017, SLACK Incorporated.

  9. Comparison of real and computer-simulated outcomes of LASIK refractive surgery

    Science.gov (United States)

    Cano, Daniel; Barbero, Sergio; Marcos, Susana

    2004-06-01

    Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were compared with real postoperative outcomes. Standard LASIK refractive surgery for myopia increased corneal asphericity and spherical aberration. Computations with the theoretical Munnerlyn ablation pattern did not increase the corneal asphericity and spherical aberration. The theoretical parabolic pattern induced a slight increase of asphericity and spherical aberration, explaining only 40% of the clinically found increase. The theoretical biconic pattern controlled corneal spherical aberration. Computations showed that the theoretical customized pattern can correct high-order asymmetric aberrations. Simulations of changes in efficiency due to reflection and nonnormal incidence of the laser light showed a further increase in corneal asphericity. Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity.

  10. Intelligent Planning for Laser Refractive Surgeries

    Science.gov (United States)

    Wang, Wei; Yue, Yong; Elsheikh, Ahmed; Bao, Fangjun

    2018-02-01

    Refractive error is one of leading ophthalmic diseases for both genders all over the world. Laser refractive correction surgery, e.g., laser in-situ keratomileusis (LASIK), has been commonly used worldwide. The prediction of surgical parameters, e.g., corneal ablation depth, depends on the doctor’s experience, theoretical formula and surgery reference manual in the preoperative diagnosis. The error of prediction may present a potential surgical risk and complication. Being aware of the surgery parameters is important because these can be used to estimate a patient’s post-operative visual quality and help the surgeon plan a suitable treatment. Therefore, in this paper we discuss data mining techniques that can be utilized for the prediction of laser refractive correction surgery parameters. It can provide the surgeon with a reference for possible surgical parameters and outcomes of the patient before the laser refractive correction surgery.

  11. Macroeconomic landscape of refractive surgery in the United States.

    Science.gov (United States)

    Corcoran, Kevin J

    2015-07-01

    This review examines the economic history of refractive surgery and the decline of laser-assisted in-situ keratomileusis (LASIK) in the USA, and the emergence of refractive cataract surgery as an area of growth. Since it peaked in 2007 at 1.4 million procedures per year, LASIK has declined 50% in the USA, whereas refractive cataract surgery, including presbyopia-correcting intraocular lenses (IOLs), astigmatism-correcting IOLs, and femtosecond laser-assisted cataract surgery, has grown to 350 000 procedures per year, beginning in 2003. Patients are price-sensitive and responsive to publicity (good or bad) about refractive surgery and refractive cataract surgery. LASIK's decline has been partially offset by the emergence of refractive cataract surgery. About 11% of all cataract surgery in the USA involves presbyopia-correcting IOLs, astigmatism-correcting IOLs, or a femtosecond laser. From the surgeon's perspective, there are high barriers to entry into the marketplace for refractive surgery and refractive cataract surgery due to the high capital cost of excimer and femtosecond lasers, the high skill level required to deliver spectacular results to demanding patients who pay out of pocket, and the necessity to perform a high volume of surgeries to satisfy both of these requirements. Probably, less than 7% of US cataract surgeons can readily meet all of these requirements.

  12. Refractive and diffractive neutron optics with reduced chromatic aberration

    Energy Technology Data Exchange (ETDEWEB)

    Poulsen, S.O., E-mail: stefan.poulsen@northwestern.edu [NEXMAP, Department of Physics, Technical University of Denmark, Anker Engelunds Vej 1, 2800 Kgs. Lyngby (Denmark); Department of Materials Science and Engineering, Northwestern University, Evanston, IL 60208 (United States); Poulsen, H.F. [NEXMAP, Department of Physics, Technical University of Denmark, Anker Engelunds Vej 1, 2800 Kgs. Lyngby (Denmark); Bentley, P.M. [European Spallation Source ESS AB, Box 176, 221 00 Lund (Sweden)

    2014-12-11

    Thermal neutron beams are an indispensable tool in physics research. The spatial and the temporal resolution attainable in experiments are dependent on the flux and collimation of the neutron beam which remain relatively poor, even for modern neutron sources. These difficulties may be mitigated by the use of optics for focusing and imaging. Refractive and diffractive optical elements, e.g. compound refractive lenses and Fresnel zone plates, are attractive due to their low cost, and simple alignment. These optical elements, however, suffer from chromatic aberration, which limit their effectiveness to highly monochromatic beams. This paper presents two novel concepts for focusing and imaging non-monochromatic thermal neutron beams with well-known optical elements: (1) a fast mechanical transfocator based on a compound refractive lens, which actively varies the number of individual lenses in the beam path to focus and image a time-of-flight beam, and (2) a passive optical element consisting of a compound refractive lens, and a Fresnel zone plate, which may focus and image both continuous and pulsed neutron beams.

  13. Refractive Surgery: Malpractice Litigation Outcomes.

    Science.gov (United States)

    Custer, Benjamin L; Ballard, Steven R; Carroll, Robert B; Barnes, Scott D; Justin, Grant A

    2017-10-01

    To review data on malpractice claims related to refractive surgery to identify common allegations and injuries and financial outcomes. The WestlawNext database was reviewed for all malpractice lawsuits/settlements related to refractive eye surgery. Data evaluated included patient demographics, type of operation performed, plaintiff allegation, nature of injury, and litigation outcomes. A total of 167 cases met the inclusion criteria, of which 108 cases (64.7%) were found to be favorable and 59 cases (35.3%) unfavorable to the defendant. A total of 141 cases were tried by a jury with 108 cases (76.4%) favorable and 33 cases (23.6%) unfavorable to the defendant. Laser in situ keratomileusis was performed in 127 cases (76%). The most common allegations were negligence in treatment or surgery in 127 cases (76%) and lack of informed consent in 83 cases (49.7%). For all cases, the need for future surgery (P = 0.0001) and surgery resulting in keratoconus (P = 0.05) were more likely to favor the plaintiff. In jury verdict decisions, cases in which failure to diagnose a preoperative condition was alleged favored the defendant (P = 0.03), whereas machine malfunction (P = 0.05) favored the plaintiff. After adjustment for inflation, the overall mean award was $1,287,872. Jury verdicts and settlements led to mean awards of $1,604,801 and $826,883, respectively. Malpractice litigation in refractive surgery tends to favor the defendant. However, large awards and settlements were given in cases that were favorable to the plaintiff. The need for future surgery and surgery leading to keratoconus increased the chance of an unfavorable outcome.

  14. Cirurgia refrativa: quem precisa de tratamento personalizado? Refractive surgery: who needs customized ablation

    Directory of Open Access Journals (Sweden)

    Wallace Chamon

    2003-01-01

    Full Text Available Estamos em uma fase de ebulição para a determinação do futuro da cirurgia refrativa corneana. Dia após dia vão se tornando mais comuns os termos como: "análise de frentes de onda", "wave front", "ablação customizada" (que seria mais adequado se fosse alterado para "ablação personalizada", "supervisão", "aberrações", etc... O que será então o futuro de todas estas tecnologias? É importante que entendamos que todos estes termos convergem para alguns fatos que são inquestionáveis. Neste texto são abordados os seguintes pontos: 1. A melhora do desempenho visual com a correção das aberrações ópticas, 2. A mudança no conceito de óptica fisiológica 3. A relação entre refração e mapa refratométrico 4. O benefício visual 5. As aberrações cromáticas e as aberrações esféricasRefractive surgery is facing an important period of its evolution. Day by day we are getting used to terms such as: "wave front", "customized ablation", "supervision", "aberrations", etc. What will be the future of all these technologies? It is important to understand that all these terms are based on some unquestionable facts. In this manuscript the following subjects were considered: 1. Improvement of visual performance when correcting optical aberrations, 2. The change in the concept of physiologic optics, 3. The relationship between refraction and refractive map 4. Visual benefit, 5. Chromatic and spherical aberrations

  15. Past and present of corneal refractive surgery

    DEFF Research Database (Denmark)

    Vestergaard, Anders Højslet

    Surgical correction of refractive errors is becoming increasingly popular. In the 1990s, the excimer laser revolutionized the field of corneal refractive surgery with PRK and LASIK, and lately refractive lenticule extraction (ReLEx) of intracorneal tissue, using only a femtosecond laser, has become...

  16. Effects of SMILE and Trans-PRK on corneal higher order aberrations after myopic correction

    Directory of Open Access Journals (Sweden)

    Jiao Zhao

    2018-02-01

    Full Text Available AIM:To observe the effects of small incision lenticule extraction(SMILEand trans-epithelial photorefractive keratectomy(Trans-PRKon corneal horizontal coma, vertical coma, and spherical aberration and total higher order aberrations after refractive correction for myopia. METHODS: This was a prospective non-randomized cohort study. The cohort included 40 patients(80 eyeswith myopia, who received refraction correction surgery from December 2016 to February 2017 in Leshan Ophthalmic Center. Twenty patients(40 eyesreceived SMILE surgery and the other 20 patients(40 eyesreceived Trans-PRK surgery. Corneal aberrations were determined by a high-resolution Pentacam Scheimpflug camera before the surgery and at 1 and 3mo after the operation. Statistical analyses were performed using analysis of variance of repeated measures. RESULTS: At 1 and 3mo post-operation, the uncorrected visual acuity in both groups was better than or equal to the preoperative best corrected visual acuity. The preoperative corneal aberrations showed no significant difference between the two groups(P>0.05. Significantly higher aberration was found after the surgery in both groups(PP>0.05. Post-operation, horizontal and vertical coma had no significant difference between the two groups(P>0.05, while SMILE group showed lower spherical aberration and lower total higher order aberration than Trans-PRK group(PCONCLUSION: Both SMILE and Trans-PRK increase corneal aberration and their effects on horizontal and vertical coma are similar. However, SMILE has a minor influence on spherical aberration and total high order aberration than Trans-PRK.

  17. Visual and Refractive Outcomes after Cataract Surgery with Implantation of a New Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Cinzia Mazzini

    2013-06-01

    Full Text Available Purpose: The aim of this study was to evaluate and report the visual, refractive and aberrometric outcomes of cataract surgery with implantation of the new aspheric Tecnis ZCT toric intraocular lens (IOL in eyes with low to moderate corneal astigmatism. Methods: We conducted a prospective study of 19 consecutive eyes of 17 patients (mean age: 78 years with a visually significant cataract and moderate corneal astigmatism [higher than 1 diopter (D] undergoing cataract surgery with implantation of the aspheric Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive and aberrometric changes were evaluated during a 6-month follow-up. Ocular aberrations as well as IOL rotation were evaluated by means of the OPD-Station II (Nidek. Results: The six-month postoperative spherical equivalent and power vector components of the refractive cylinder were within ±0.50 D in all eyes (100%. Postoperative logMAR uncorrected and corrected distance visual acuities (UDVA/CDVA were 0.1 (about 20/25 or better in almost all eyes (94.74%. The mean logMAR CDVA improved significantly from 0.41 ± 0.23 to 0.02 ± 0.05 (p Conclusion: Cataract surgery with implantation of the aspheric Tecnis ZCT IOL is a predictable and effective procedure for visual rehabilitation in eyes with cataract and low to moderate corneal astigmatism, providing an excellent postoperative ocular optical quality.

  18. Comparison of monochromatic aberrations in young adults with different visual acuity and refractive errors.

    Science.gov (United States)

    Yazar, Seyhan; Hewitt, Alex W; Forward, Hannah; McKnight, Charlotte M; Tan, Alex; Mountain, Jenny A; Mackey, David A

    2014-03-01

    To compare the monochromatic aberrations in a large cohort of 20-year-old Australians with differing levels of visual acuity and explore the relationship between these aberrations and refractive error. Lions Eye Institute, Perth, Western Australia, Australia. Cross-sectional analysis of a population-based cohort. Monochromatic aberrations were measured using a Zywave II wavefront aberrometer with natural pupils in a dark room. The logMAR corrected distance visual acuity (CDVA) was measured monocularly under normal illumination. Cycloplegic autorefraction was also performed. The study enrolled 2039 eyes of 1040 participants. Data from 1007 right eyes were analyzed. The median CDVA and spherical equivalent were -0.06 logMAR (interquartile range [IQR], -0.10 to 0.00) and +0.25 diopters (D) (IQR, -0.38 to 0.63), respectively. The median 6.0 mm higher-order aberration (HOA) was 0.58 μm (IQR, 0.44 to 0.79). Coma-like aberrations and 3rd-, 4th-, and 5th-order HOAs were significantly different between subjects with a CDVA of -0.10 logMAR or better and those with a CDVA worse than -0.10 logMAR. Fourth-order aberrations Z(4,-4) (P=.024) and Z(4,-2) (P=.029) and 2nd-order aberration Z(2,0) (Peyes, emmetropic eyes, and hyperopic eyes. Subjects with higher myopia had slightly higher total HOAs. The HOAs in this population were marginally higher than previously reported values. The findings confirm there is a difference in monochromatic aberrations between different vision and refractive groups. Results in this study will benefit decision-making processes in the clinical setting. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Anterior segment surgery IOLs, lasers, and refractive keratoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Stark, W.J.; Terry, A.C.; Maumenee, A.E.

    1987-01-01

    The contributors to this text combine their expertise to make this book available on intraocular lenses, refractive corneal surgery, and the use of the YAG laser. Included is information on; IOL power calculations; the use of the YAG laser; retinal damage by short wavelength light; reviews of corneal refractive surgery; possibilities for the medical prevention of cataracts; and more.

  20. Automated refraction is stable 1 week after uncomplicated cataract surgery

    DEFF Research Database (Denmark)

    Ostri, Christoffer; Holfort, Stig K; Fich, Marianne S

    2018-01-01

    PURPOSE: To compare automated refraction 1 week and 1 month after uncomplicated cataract surgery. METHODS: In this prospective cohort study, we recruited patients in a 2-month period and included consecutive patients scheduled for bilateral small-incision phacoemulsification cataract surgery....... The exclusion criteria were (i) corneal and/or retinal pathology that could lead to automated refraction miscalculation and (ii) surgery complications. Automated refraction was measured 1 week and 1 month after surgery. RESULTS: Ninety-five patients met the in- and exclusion criteria and completed follow......-up. The mean refractive shift in spherical equivalent was -0.02 dioptre (D) between 1 week and 1 month after surgery and not statistical significant (p = 0.78, paired t-test). The magnitude of refractive shift in either myopic or hyperopic direction was neither correlated to age, preoperative corneal...

  1. Corneal polarimetry after LASIK refractive surgery

    Science.gov (United States)

    Bueno, Juan M.; Berrio, Esther; Artal, Pablo

    2006-01-01

    Imaging polarimetry provides spatially resolved information on the polarization properties of a system. In the case of the living human eye, polarization could be related to the corneal biomechanical properties, which vary from the normal state as a result of surgery or pathologies. We have used an aberro-polariscope, which we recently developed, to determine and to compare the spatially resolved maps of polarization parameters across the pupil between normal healthy and post-LASIK eyes. The depolarization distribution is not uniform across the pupil, with post-surgery eyes presenting larger levels of depolarization. While retardation increases along the radius in normal eyes, this pattern becomes irregular after LASIK refractive surgery. The maps of slow axis also differ in normal and post-surgery eyes, with a larger disorder in post-LASIK eyes. Since these changes in polarization indicate subtle structural modifications of the cornea, this approach can be useful in a clinical environment to follow the biomechanical and optical changes of the cornea after refractive surgery or for the early diagnosis of different corneal pathologies.

  2. Is LASIK for Me? A Patient's Guide to Refractive Surgery

    Science.gov (United States)

    Is LASIK for Me? A Patient’s Guide to Refractive Surgery October 2008 Is LASIK for Me? A Patient’s Guide to Refractive Surgery Table of Contents LASIK: A COMPREHENSIVE GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What Is ...

  3. Deviations of Lambert-Beer???s law affect corneal refractive parameters after refractive surgery

    OpenAIRE

    Jim??nez Cuesta, Jos?? Ram??n; Rodr??guez-Mar??n, Francisco; Gonz??lez Anera, Rosario; Jim??nez del Barco Jaldo, Luis Miguel

    2006-01-01

    We calculate whether deviations of Lambert-Beer???s law, which regulates depth ablation during corneal ablation, significantly influence corneal refractive parameters after refractive surgery and whether they influence visual performance. For this, we compute a point-to-point correction on the cornea while assuming a non-linear (including a quadratic term) fit for depth ablation. Post-surgical equations for refractive parameters using a non-linear fit show significant differences with respect...

  4. Refractive surgery trends and practice style changes in Germany over a 3-year period.

    Science.gov (United States)

    Schmack, Ingo; Auffarth, Gerd U; Epstein, Daniel; Holzer, Mike P

    2010-03-01

    To study the current practice styles and preferences of refractive surgeons in Germany. In February 2008, a seven-item questionnaire regarding the practice of refractive surgery was mailed to 282 members of the German Society of Intra-ocular Lens Implantation, Interventional, and Refractive Surgery (DGII) and the Commission of Refractive Surgery (KRC). Most questions were identical to our 2005 German refractive surgery survey. All data were analyzed in a masked fashion. The response rate was 42.2%. The majority (68%) of respondents reported that they perform refractive surgery in laser centers (exclusively or partially) followed by general hospitals (19.4%) and universities (12.6%). Although LASIK was the predominant type of refractive surgery performed (80.6%), other refractive procedures included refractive lens exchange (60.2%), photorefractive keratectomy (47.6%), phakic intraocular lens implants (45.6%), laser-assisted subepithelial keratectomy (36.9%), epithelial laser in situ keratomileusis (15.5%), intracorneal rings (5.8%), and limbal relaxing incisions (2.9%). The volume of refractive surgery procedures and the preferred type of excimer laser systems, microkeratomes, and diagnostic devices varied at different institutions. Most respondents performed either wavefront-guided custom ablation or wavefront-optimized ablation (63.1%) compared with conventional excimer laser correction (36.9%). Refractive surgery practice styles and preferences in Germany are comparable to trends in other European countries. Although LASIK is the most commonly performed refractive procedure, the numbers of various surface ablation techniques and refractive intraocular lens procedures are increasing. Copyright 2010, SLACK Incorporated.

  5. Indications for and outcomes of tertiary referrals in refractive surgery

    NARCIS (Netherlands)

    Patryn, Eliza K.; Vrijman, Violette; Nieuwendaal, Carla P.; van der Meulen, Ivanka J. E.; Mourits, Maarten P.; Lapid-Gortzak, Ruth

    2014-01-01

    To review the spectrum of disease, symptomatology, and management offered to patients referred for a second opinion after refractive surgery. A prospective cohort study was done on all patients referred from October 1, 2006, to September 30, 2011, to a tertiary eye clinic after refractive surgery of

  6. Trends in refractive surgery at an academic center: 2007-2009

    OpenAIRE

    Kuo, Irene C

    2011-01-01

    Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in t...

  7. Trends in refractive surgery at an academic center: 2007-2009

    Directory of Open Access Journals (Sweden)

    Kuo Irene C

    2011-05-01

    Full Text Available Abstract Background The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Methods Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK vs. laser-assisted in-situ keratomileusis (LASIK, and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Results Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10. The

  8. Trends in refractive surgery at an academic center: 2007-2009.

    Science.gov (United States)

    Kuo, Irene C

    2011-05-14

    The United States officially entered a recession in December 2007, and it officially exited the recession in December 2009, according to the National Bureau of Economic Research. Since the economy may affect not only the volume of excimer laser refractive surgery, but also the clinical characteristics of patients undergoing surgery, our goal was to compare the characteristics of patients completing excimer laser refractive surgery and the types of procedures performed in the summer quarter in 2007 and the same quarter in 2009 at an academic center. A secondary goal was to determine whether the volume of astigmatism- or presbyopia-correcting intraocular lenses (IOLs) has concurrently changed because like laser refractive surgery, these "premium" IOLs involve out-of-pocket costs for patients. Retrospective case series. Medical records were reviewed for all patients completing surgery at the Wilmer Laser Vision Center in the summer quarter of 2007 and the summer quarter of 2009. Outcome measures were the proportions of treated refractive errors, the proportion of photorefractive keratectomy (PRK) vs. laser-assisted in-situ keratomileusis (LASIK), and the mean age of patients in each quarter. Chi-square test was used to compare the proportions of treated refractive errors and the proportions of procedures; two-tailed t-test to compare the mean age of patients; and two-tailed z-test to compare proportions of grouped refractive errors in 2007 vs. 2009; alpha = 0.05 for all tests. Refractive errors were grouped by the spherical equivalent of the manifest refraction and were considered "low myopia" for 6 diopters (D) of myopia or less, "high myopia" for more than 6 D, and "hyperopia" for any hyperopia. Billing data were reviewed to obtain the volume of premium IOLs. Volume of laser refractive procedures decreased by at least 30%. The distribution of proportions of treated refractive errors did not change (p = 0.10). The proportion of high myopes, however, decreased (p = 0

  9. Refractive surgery or contact lenses – how and when to decide?

    Directory of Open Access Journals (Sweden)

    Xu K

    2011-11-01

    Full Text Available Kunyong Xu1, Vishal Jhanji2 1Michael G DeGroote School of Medicine, McMaster University, Hamilton, Ontario, Canada; 2Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong Abstract: Correction of refractive errors can be achieved with spectacles, contact lenses, and refractive surgery. The past decade has seen a surge in the availability of alternatives for patients and surgeons in terms of both surgical and nonsurgical options for the management of refractive errors. Newer generation contact lenses provide enhanced safety and better handling, whereas modern-day refractive surgery presents a plethora of choices based on the clinical characteristics and requirements of patients. We have moved from an era of "one size fits all" to a purely customized way of treating patients with refractive errors. This review presents the background, advantages, and disadvantages of the two most commonly used options for correction of ametropia, ie, contact lenses and refractive surgery. Keywords: laser-assisted in situ keratomileusis, contact lens, patient selection, complications, outcomes

  10. About the correctness of laser refractive surgery in children

    Directory of Open Access Journals (Sweden)

    V. V. Kurenkov

    2016-01-01

    Full Text Available Disturbances of refraction are one of the most urgent problems of pediatric ophthalmology. Late and incomplete correction of refractive errors leads to the development of amblyopia, disturbances of binocular vision, the appearance of strabismus. Such complications reduce the quality of life, drastically limit the choice of professional child. Pediatric Ophthalmology always face a choice: many drugs and technologies are not approved for use in pediatric patients, practitioners are forced to use their «off-label», but such situations require great care and strict medical indications. For example, refractive surgery has worked well in adults, but its use remains controversial in children for security reasons and unpredictable effects. Several authors have described the use of laser refractive surgery in children under the age of 18 years, but there are no results of a multicenter, controlled study evaluating the safety, efficacy, and especially long-term results. In all the studies, the calculation was performed on adult nomograms ablation, while not proved how they are accurate for children. Long-term results and data on the endothelial cell density, corneal curvature changes in catamnesis are presented no longer than two years. Despite the fact that currently there is insufficient information about the results of remote application keratorefractive laser surgery in children, and there are no indication system and contraindications, modern achievements in medicine should be used in pediatric patients, and our successful track record proves it clearly. Undoubtedly, the positive experience of the laser surgery use in a child with clouding of the cornea in the outcome of herpetic keratitis, which provided a positive result: high visual acuity, binocular vision and lack of infection relapses for 2 years, requires study, evidence multicenter studies, and possibly expansion of indications for refractive laser surgery.

  11. Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device.

    Science.gov (United States)

    Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P

    2015-08-01

    To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Strategies for the management and prevention of complications in refractive laser surgery

    NARCIS (Netherlands)

    F. Hafezi (Farhad)

    2008-01-01

    textabstractObjective. Reoperations after refractive surgery have increased in frequency during the past 10 years. The spectrum of the indications for repeat LASIK may have changed. Methods. All cases of reoperations after refractive surgery performed between May 1, 2004 and April 30, 2005 at the

  13. New Refractive Surgery Procedures and Their Implications for Aviation Safety

    National Research Council Canada - National Science Library

    Nakagawara, Van B; Wood, Kathryn J; Montgomery, Ron W

    2006-01-01

    ...., myopia, hyperopia, astigmatism) with corrective surgery. Prior Federal Aviation Administration research studies have shown that the number of civil airmen with refractive surgery continues to increase...

  14. Eye laterality: a comprehensive analysis in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Druchkiv, Vasyl; Steinberg, Johannes; Richard, Gisbert; Katz, Toam

    2013-08-01

    To explore eye laterality (higher refractive error in one eye) and its association with refractive state, spherical/astigmatic anisometropia, age and sex in refractive surgery candidates. Medical records of 12 493 consecutive refractive surgery candidates were filtered. Refractive error (subjective and cycloplegic) was measured in each subject and correlated with eye laterality. Only subjects with corrected distance visual acuity (CDVA) of >20/22 in each eye were enrolled to exclude amblyopia. Associations between eye laterality and refractive state were analysed by means of t-test, chi-squared test, Spearman's correlation and multivariate logistic regression analysis, respectively. There was no statistically significant difference in spherical equivalent between right (-3.47 ± 2.76 D) and left eyes (-3.47 ± 2.76 D, p = 0.510; Pearson's r = 0.948, p laterality for anisometropia >2.5 D in myopic (-5.64 ± 2.5 D versus -4.92 ± 2.6 D; p = 0.001) and in hyperopic (4.44 ± 1.69 D versus 3.04 ± 1.79 D; p = 0.025) subjects, (II) a tendency for left eye cylindrical laterality in myopic subjects, and (III) myopic male subjects had a higher prevalence of left eye laterality. (IV) Age did not show any significant impact on laterality. Over the full refractive spectrum, this study confirmed previously described strong interocular refractive correlation but revealed a statistically significant higher rate of right eye laterality for anisometropia >2.5 D. In general, our results support the use of data from one eye only in studies of ocular refraction. © 2013 The Authors. Acta Ophthalmologica © 2013 Acta Ophthalmologica Scandinavica Foundation.

  15. The New Zealand cataract and refractive surgery survey 1997/1998.

    Science.gov (United States)

    Elder, M; Tarr, K; Leaming, D

    2000-04-01

    This study documents the current practice for cataract and refractive surgery in New Zealand. A postal questionnaire was distributed in late 1997 to all consultant members of the Ophthalmological Society of New Zealand that were resident in the country at that time. Most questions were identical to the 1997 survey of the American Society of Cataract and Refraction Surgeons (ASCRS) to enable a comparison. There were 98 returns from 101 surveys distributed. Of the returns, 72 performed cataract surgery, 23 performed PRK and 11 performed LASIK. ASCRS members did more refractive surgery than did New Zealanders: 28 versus 1% of 1-5 RK per month, 7 versus 1% of 1-2 clear lens extractions per month and 85 versus 51% had access to an excimer laser. For cataract surgery, ASCRS members used more topical anaesthesia (30 vs 5.5%), used no sutures more often (73 vs 51%), used more preoperative antibiotics (76 vs 26%) and used fewer injections of antibiotic/steroids (38 vs 61%). Otherwise the two groups were broadly similar.

  16. Risk assessment for ectasia after corneal refractive surgery.

    Science.gov (United States)

    Randleman, J Bradley; Woodward, Maria; Lynn, Michael J; Stulting, R Doyle

    2008-01-01

    To analyze the epidemiologic features of ectasia after excimer laser corneal refractive surgery, to identify risk factors for its development, and to devise a screening strategy to minimize its occurrence. Retrospective comparative and case-control study. All cases of ectasia after excimer laser corneal refractive surgery published in the English language with adequate information available through December 2005, unpublished cases seeking treatment at the authors' institution from 1998 through 2005, and a contemporaneous control group who underwent uneventful LASIK and experienced a normal postoperative course. Evaluation of preoperative characteristics, including patient age, gender, spherical equivalent refraction, pachymetry, and topographic patterns; perioperative characteristics, including type of surgery performed, flap thickness, ablation depth, and residual stromal bed (RSB) thickness; and postoperative characteristics including time to onset of ectasia. Development of postoperative corneal ectasia. There were 171 ectasia cases, including 158 published cases and 13 unpublished cases evaluated at the authors' institution. Ectasia occurred after LASIK in 164 cases (95.9%) and after photorefractive keratectomy (PRK) in 7 cases (4.1%). Compared with controls, more ectasia cases had abnormal preoperative topographies (35.7% vs. 0%; Pvs. 40.0 years; Pvs. -5.09 diopters; Pvs. 546.5 microm; Pvs. 317.3 microm; PLASIK that, if validated, represents a significant improvement over current screening strategies.

  17. Wavefront coherence area for predicting visual acuity of post-PRK and post-PARK refractive surgery patients

    Science.gov (United States)

    Garcia, Daniel D.; van de Pol, Corina; Barsky, Brian A.; Klein, Stanley A.

    1999-06-01

    Many current corneal topography instruments (called videokeratographs) provide an `acuity index' based on corneal smoothness to analyze expected visual acuity. However, post-refractive surgery patients often exhibit better acuity than is predicted by such indices. One reason for this is that visual acuity may not necessarily be determined by overall corneal smoothness but rather by having some part of the cornea able to focus light coherently onto the fovea. We present a new method of representing visual acuity by measuring the wavefront aberration, using principles from both ray and wave optics. For each point P on the cornea, we measure the size of the associated coherence area whose optical path length (OPL), from a reference plane to P's focus, is within a certain tolerance of the OPL for P. We measured the topographies and vision of 62 eyes of patients who had undergone the corneal refractive surgery procedures of photorefractive keratectomy (PRK) and photorefractive astigmatic keratectomy (PARK). In addition to high contrast visual acuity, our vision tests included low contrast and low luminance to test the contribution of the PRK transition zone. We found our metric for visual acuity to be better than all other metrics at predicting the acuity of low contrast and low luminance. However, high contrast visual acuity was poorly predicted by all of the indices we studied, including our own. The indices provided by current videokeratographs sometimes fail for corneas whose shape differs from simple ellipsoidal models. This is the case with post-PRK and post-PARK refractive surgery patients. Our alternative representation that displays the coherence area of the wavefront has considerable advantages, and promises to be a better predictor of low contrast and low luminance visual acuity than current shape measures.

  18. Topical cyclosporine a treatment in corneal refractive surgery and patients with dry eye.

    Science.gov (United States)

    Torricelli, Andre A M; Santhiago, Marcony R; Wilson, Steven E

    2014-08-01

    To evaluate preoperative and postoperative dry eye and the effect of cyclosporine A treatment in patients screened for corneal refractive surgery and treated with photorefractive keratectomy (PRK) or LASIK. A consecutive case series of 1,056 patients screened for corneal refractive surgery from 2007 to 2012 was retrospectively analyzed. The level of preoperative and postoperative dry eye and the responsiveness to topical cyclosporine A treatment were assessed. One eye of each patient was randomly selected. A total of 642 eyes progressed to surgery: 524 (81.6%) and 118 (18.4%) underwent LASIK and PRK, respectively. Of 81 (7.7%) diagnosed as having dry eye, 55 were deemed potential candidates and optimized for refractive surgery. Thirty-seven patients with moderate dry eye were treated with topical cyclosporine A prior to surgery (mean duration: 3.2 ± 2.1 months; range: 1 to 12 months). After cyclosporine A treatment, 28 (75.7%) eyes underwent LASIK, 4 (10.8%) eyes underwent PRK, and 5 (13.5%) eyes were not operated on due to failed treatment of dry eye. Postoperative refractive surgery-induced neurotrophic epitheliopathy (LINE in LASIK) was noted in 132 (27.3%) and 12 (11.1%) eyes that underwent LASIK and PRK, respectively. Topical cyclosporine A was prescribed in 79 LASIK-induced and 3 PRK-induced dry eyes. After 12 months or more of cyclosporine A treatment, 5 (6.1%) eyes continued to have dry eye symptoms or signs. Topical cyclosporine A treatment is effective therapy for optimizing patients for refractive surgery and treatment of new onset or worsened dry eye after surgery. Copyright 2014, SLACK Incorporated.

  19. Seven-year changes in corneal power and aberrations after PRK or LASIK.

    Science.gov (United States)

    Ivarsen, Anders; Hjortdal, Jesper

    2012-09-06

    To examine long-term changes in corneal power and aberrations in myopic patients randomized to photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). Forty-five patients with myopia from -6 to -8 diopters (spherical equivalent refraction) were randomized to PRK (n = 20) or LASIK (n = 25). Patients were examined preoperatively and for up to 7 years after surgery. Measurements included refraction, topography (TMS-1), and ultrasound pachymetry. By 3 years, 16 PRK and 15 LASIK patients were examined and by 7 years, 9 PRK and 7 LASIK subjects were available. Only patients who had not been reoperated and attended the two late controls were included in data analyses. Optical analysis of topographic data was used to calculate corneal power and wavefront aberrations. PRK and LASIK caused a similar reduction in corneal power. During the first year after PRK, corneal power increased, but remained stable from 1 to 7 years. In contrast, corneal power continued to increase from 1 to 7 years after LASIK. Both PRK and LASIK caused an increase in coma-like and spherical aberrations that remained constant for 7 years. No significant changes in other higher-order aberrations were observed. The cornea may not be stable even 7 years after LASIK, as indicated by the continuing increase in corneal power. In contrast, PRK appears stable from 1 year post surgery. Coma-like and spherical aberrations are permanently increased after PRK and LASIK. (ClinicalTrials.gov number, NCT00404105.).

  20. [Complications after refractive surgery abroad].

    Science.gov (United States)

    Terzi, E; Kern, T; Kohnen, T

    2008-05-01

    In this article a retrospective analysis of patients presenting at a German university following refractive surgery abroad is presented. A total of 20 cases of patients who had undergone treatment between 1998 and 2006 in China (1 case), Greece (1 case), Iran (1 case), Russia (2 cases), Switzerland (1 case), Slovakia (1 case), Spain (2 cases), South Africa (3 cases), Turkey (6 cases) and the USA (2 cases) were analyzed retrospectively. The following complications were observed: epithelial ingrowth into the interface with or without melting of the flap (6 cases), corneal ectasia (2 cases), dislocation of a phakic posterior chamber intraocular lens and prolapse into the anterior chamber with endothelial cell loss (1 case), secondary increase of intraocular pressure following implantation of a phakic intraocular lens (1 case), flap-related complications following laser-in-situ keratomileusis (LASIK) (2 cases), keratitis (1 case), dislocation of the complete flap (1 case), diffuse lamellar keratitis (DLK) grade IV (1 case), hyperopia as a consequence of radial keratotomy (1 case), and under correction/over correction and poor optical quality following laser epithelial keratomileusis (LASEK) and LASIK for high myopia (5 cases) with possible early corneal ectasia. There are four important problems arising from refractive surgery abroad, often referred to as "LASIK tourism": wrong indications, insufficient management of complications, lack of postoperative care and the health economic aspect.

  1. A Novel Laser Refractive Surgical Treatment for Presbyopia: Optics-Based Customization for Improved Clinical Outcome.

    Science.gov (United States)

    Pajic, Bojan; Pajic-Eggspuehler, Brigitte; Mueller, Joerg; Cvejic, Zeljka; Studer, Harald

    2017-06-13

    Laser Assisted in Situ Keratomileusis (LASIK) is a proven treatment method for corneal refractive surgery. Surgically induced higher order optical aberrations were a major reason why the method was only rarely used to treat presbyopia, an age-related near-vision loss. In this study, a novel customization algorithm for designing multifocal ablation patterns, thereby minimizing induced optical aberrations, was used to treat 36 presbyopic subjects. Results showed that most candidates went from poor visual acuity to uncorrected 20/20 vision or better for near (78%), intermediate (92%), and for distance (86%) vision, six months after surgery. All subjects were at 20/25 or better for distance and intermediate vision, and a majority (94%) were also better for near vision. Even though further studies are necessary, our results suggest that the employed methodology is a safe, reliable, and predictable refractive surgical treatment for presbyopia.

  2. [Advocating standardization and customization of corneal refractive surgery in Chinese domestic situation].

    Science.gov (United States)

    Zhang, F J; Song, Y Z

    2016-07-01

    With the improvement and application of excimer laser and femtosecond laser equipment in clinical ophthalmology, the diversified strategies for corneal refractive surgery candidates have been provided. Based on the trend of " all-laser treatment", it is very necessary to take the domestic situation into consideration when a standard and customized choice is made according to the indications of each specific surgical type. The characteristics and limitations of various surgeries are elucidated and commented here in order to provide some reasonable treatment options for refractive surgery. (Chin J Ophthalmol, 2016, 52: 481-485).

  3. Comparison of biometric predictability and final refraction expected in phacoemulsification surgery with and without trabeculectomy

    Directory of Open Access Journals (Sweden)

    Fernanda Guedes Oliveira

    Full Text Available Abstract Objective: The main purpose of this article is to compare the predictability of biometric results and final refractive outcomes expected in patients undergoing cataract surgery through phacoemulsification with and without associated trabeculectomy. Methods: Cataract patients who have undergone phacoemulsification surgery alone (control group or associated with trabeculectomy (study group screened. All surgeries were performed following standard protocol. For enrollment, biometrics calculated by IOL Master (Carl Zeiss Meditec, Inc. biometry, refraction and intraocular pressure (IOP before and after surgery were required. Data was compared between groups in addition to the correlation between variation of IOP and final refraction. Results: Thirty eyes per group were enrolled. Only prior IOP (p <0.001, IOP post-surgery (p = 0.01 and the difference in IOP (p <0.001 were statistically significant. Axial length, IOL diopter used, expected spherical refraction by biometrics and astigmatism pre- and post-surgery were similar in both groups (p=0.1; 0.4; 0.4; 0.5 and 0.3, respectively. Spherical predictability by biometrics within 0.25 diopters was noted in both the control group (range 0.06 ± 0.45 and study group (range 0.25 ± 0.97, p = 0.3. There was no statistical significance between groups for the difference between final cylinder and corneal astigmatism (p = 0.9, and the difference between axis of refractive and corneal astigmatism (p = 0.7. Conclusion: The biometric predictability in phacoemulsification surgery and the expected final refraction are significant, andare not modified by trabeculectomy in the combined surgeries.

  4. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    Science.gov (United States)

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  5. SMILE and Wavefront-Guided LASIK Out-Compete Other Refractive Surgeries in Ameliorating the Induction of High-Order Aberrations in Anterior Corneal Surface

    Science.gov (United States)

    2016-01-01

    Purpose. To compare the change of anterior corneal higher-order aberrations (HOAs) after laser in situ keratomileusis (LASIK), wavefront-guided LASIK with iris registration (WF-LASIK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), and small incision lenticule extraction (SMILE). Methods. In a prospective study, 82 eyes underwent LASIK, 119 eyes underwent WF-LASIK, 88 eyes underwent FS-LASIK, and 170 eyes underwent SMILE surgery. HOAs were measured with Pentacam device preoperatively and 6 months after surgery. The aberrations were described as Zernike polynomials, and analysis focused on total HOAs, spherical aberration (SA), horizontal coma, and vertical coma over 6 mm diameter central corneal zone. Results. Six months postoperatively, all procedures result in increase of anterior corneal total HOAs and SA. There were no significant differences in the induced HOAs between LASIK and FS-LASIK, while SMILE induced fewer total HOAs and SA compared with LASIK and FS-LASIK. Similarly, WF-LASIK also induced less total HOAs than LASIK and FS-LASIK, but only fewer SA than FS-LASIK (P LASIK, whereas SMILE induced more horizontal coma and vertical coma compared with WF-LASIK (P LASIK and LASIK induced comparable anterior corneal HOAs. Compared to LASIK and FS-LASIK, both SMILE and WF-LASIK showed advantages in inducing less total HOAs. In addition, SMILE also possesses better ability to reduce the induction of SA in comparison with LASIK and FS-LASIK. However, SMILE induced more horizontal coma and vertical coma compared with WF-LASIK, indicating that the centration of SMILE procedure is probably less precise than WF-LASIK. PMID:27818792

  6. SMILE and Wavefront-Guided LASIK Out-Compete Other Refractive Surgeries in Ameliorating the Induction of High-Order Aberrations in Anterior Corneal Surface

    OpenAIRE

    Ye, Min-jie; Liu, Cai-yuan; Liao, Rong-feng; Gu, Zheng-yu; Zhao, Bing-ying; Liao, Yi

    2016-01-01

    Purpose. To compare the change of anterior corneal higher-order aberrations (HOAs) after laser in situ keratomileusis (LASIK), wavefront-guided LASIK with iris registration (WF-LASIK), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), and small incision lenticule extraction (SMILE). Methods. In a prospective study, 82 eyes underwent LASIK, 119 eyes underwent WF-LASIK, 88 eyes underwent FS-LASIK, and 170 eyes underwent SMILE surgery. HOAs were measured with Pentacam device pr...

  7. One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE).

    Science.gov (United States)

    Sekundo, Walter; Gertnere, Jana; Bertelmann, Thomas; Solomatin, Igor

    2014-05-01

    To report one year results of the first cohort of routine refractive lenticule extraction through a small incision (ReLEx SMILE) for correction of myopia and myopic astigmatism. Fifty-four eyes of 27 patients with spherical equivalent of -4.68 ± 1.29D who underwent routine ReLEx SMILE by a single surgeon were prospectively followed-up for 1 year. We used the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Germany) with a 500 kHz repetition rate. Folow-up intervals were at 1 day, 1 week, 1, 3, 6, and 12 months after surgery. We obtained following parameters: uncorrected (UDVA) and distance-corrected visual acuity (CDVA), contrast sensitivity, and wave front measurements. We also recorded all complications. Because of suction loss in one eye, 12-month results were obtained in 53 eyes as follows. After 1 year, 88% of eyes with plano target had an UDVA of 20/20 or better. Twelve percent of eyes lost 1 line of CDVA, while 31% gained 1 line and 3% gained 2 lines. The mean SE after 1 year was -0.19 ± 0.19. The mean refraction change between month 1 and 12 was 0.08 D. Neither mesopic nor photopic contrast sensitivity showed any significant changes. The high-order aberrations (HOA) increased from 0.17 to 0.27 μm (Malacara notation). No visually threatening complications were observed. In this first cohort, ReLEx SMILE produced satisfactory refractive outcomes with moderate induction of HOA and unaffected contrast sensitivity after 1 year.

  8. Wave aberrations in rhesus monkeys with vision-induced ametropias

    Science.gov (United States)

    Ramamirtham, Ramkumar; Kee, Chea-su; Hung, Li-Fang; Qiao-Grider, Ying; Huang, Juan; Roorda, Austin; Smith, Earl L.

    2007-01-01

    The purpose of this study was to investigate the relationship between refractive errors and high-order aberrations in infant rhesus monkeys. Specifically, we compared the monochromatic wave aberrations measured with a Shack-Hartman wavefront sensor between normal monkeys and monkeys with vision-induced refractive errors. Shortly after birth, both normal monkeys and treated monkeys reared with optically induced defocus or form deprivation showed a decrease in the magnitude of high-order aberrations with age. However, the decrease in aberrations was typically smaller in the treated animals. Thus, at the end of the lens-rearing period, higher than normal amounts of aberrations were observed in treated eyes, both hyperopic and myopic eyes and treated eyes that developed astigmatism, but not spherical ametropias. The total RMS wavefront error increased with the degree of spherical refractive error, but was not correlated with the degree of astigmatism. Both myopic and hyperopic treated eyes showed elevated amounts of coma and trefoil and the degree of trefoil increased with the degree of spherical ametropia. Myopic eyes also exhibited a much higher prevalence of positive spherical aberration than normal or treated hyperopic eyes. Following the onset of unrestricted vision, the amount of high-order aberrations decreased in the treated monkeys that also recovered from the experimentally induced refractive errors. Our results demonstrate that high-order aberrations are influenced by visual experience in young primates and that the increase in high-order aberrations in our treated monkeys appears to be an optical byproduct of the vision-induced alterations in ocular growth that underlie changes in refractive error. The results from our study suggest that the higher amounts of wave aberrations observed in ametropic humans are likely to be a consequence, rather than a cause, of abnormal refractive development. PMID:17825347

  9. Optical Aberrations and Wavefront

    Directory of Open Access Journals (Sweden)

    Nihat Polat

    2014-08-01

    Full Text Available The deviation of light to create normal retinal image in the optical system is called aberration. Aberrations are divided two subgroup: low-order aberrations (defocus: spherical and cylindrical refractive errors and high-order aberrations (coma, spherical, trefoil, tetrafoil, quadrifoil, pentafoil, secondary astigmatism. Aberrations increase with aging. Spherical aberrations are compensated by positive corneal and negative lenticular spherical aberrations in youth. Total aberrations are elevated by positive corneal and positive lenticular spherical aberrations in elderly. In this study, we aimed to analyze the basic terms regarding optic aberrations which have gained significance recently. (Turk J Ophthalmol 2014; 44: 306-11

  10. Theoretical investigation of aberrations upon ametropic human eyes

    Science.gov (United States)

    Tan, Bo; Chen, Ying-Ling; Lewis, J. W. L.; Baker, Kevin

    2003-11-01

    The human eye aberrations are important for visual acuity and ophthalmic diagnostics and surgical procedures. Reported monochromatic aberration data of the normal 20/20 human eyes are scarce. There exist even fewer reports of the relation between ametropic conditions and aberrations. We theoretically investigate the monochromatic and chromatic aberrations of human eyes for refractive errors of -10 to +10 diopters. Schematic human eye models are employed using optical design software for axial, index, and refractive types of ametropia.

  11. Comparison of quality of life between myopic patients with spectacles and contact lenses, and patients who have undergone refractive surgery

    Directory of Open Access Journals (Sweden)

    Nastaran Shams

    2015-03-01

    Conclusion: Quality of life for people with myopia who had the refractive surgery was better than people with myopia who wore spectacles or contact lenses. Although quality of life in people with myopia who had the refractive surgery was less than emmetropia, it seems that refractive surgery improves quality of life of myopic patients.

  12. Effects of different cutting centers on LASIK surgery in myopic patients

    Directory of Open Access Journals (Sweden)

    Yan-Wei Liu

    2017-07-01

    Full Text Available AIM:To investigate the effect of different cutting centers on the visual acuity, refractive diopter and visual quality of patients undergoing laser assisted in situ keratomileusis(LASIK. METHODS: A total of 80 patients(160 eyeswith myopia treated by elective LASIK were divided into two groups. Thirty-six cases(72 eyeswith visual axis corneal reflection point(VACRPas the cutting center were included into the VACRP group while 44 cases(88 eyeswith pupil center(PCas the cutting center were included into the PC group. The uncorrected visual acuity(UCVA, the best corrected visual acuity(BCVA, refractive diopter, corneal aberration \\〖total corneal and anterior corneal surface higher-order aberrations(HOA, spherical aberration(Z40, vertical coma(Z3-1, horizontal coma(totZ31and offset of cutting centers were determined before surgery and 1mo after surgery. RESULTS: There was no difference in the probability of UCVA ≥ 0.1, BCVA and refractive diopter between the two groups at 1mo after surgery(P>0.05. The astigmatism and cutting center deviation of VACRP group were lower than those of PC group(P40, totZ3-1, totZ31, froHOA, froZ3-1、froZ31 and froZ40 were lower in VACRP group than PC group at 1mo after surgery(PCONCLUSION: The UCVA of patients treated with both cutting centers for LASIK is good but VACRP has more advantages in reducing the offset of cutting center and improving postoperative visual quality.

  13. Comparison of the visual and intraocular optical performance of a refractive multifocal IOL with rotational asymmetry and an apodized diffractive multifocal IOL.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José

    2012-02-01

    To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.

  14. Excimer laser corneal surgery and free oxygen radicals.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Akata, F; Hasanreisoğlu, B; Türközkan, N

    1996-01-01

    Corneal photoablation with 193 nm argon fluoride excimer laser is a new technique for the treatment of refractive errors and for removing corneal opacities and irregularities. Ultraviolet radiation and thermal injury induce free radical formation in the tissues. The aim of this study was to confirm the production of free radicals by excimer laser photoablation in rabbits. The thermal changes of the posterior corneal surface were recorded during excimer laser photoablation. The lipid peroxide (LPO) levels and superoxide dismutase (SOD) activities of aqueous humour were measured after excimer laser keratectomy. The aqueous LPO levels were not changed after excimer laser ablation, but both the thermal increase in the cornea during the photoablation and the decreased aqueous SOD activities suggest that free radicals are formed in the cornea during excimer laser keratectomy, and that they may be responsible for some of the complications of excimer laser corneal surgery.

  15. Preliminary observation of refractive cataract surgery assisted by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Xiao-Li Wang

    2015-12-01

    Full Text Available AIM:To compare the differences of visual acuity and corneal astigmatism postoperatively between conventional refractive cataract surgery and that assisted by femtosecond laser.METHODS:Sixty patients(60 eyeswith age-related cataract and cornea astigmatism were divided into femtosecond group and conventional group randomly or voluntarily. The flat shaft, steep shaft and diopter of corneal astigmatism in patients in femtosecond group were inputted into the online vector calculators to get the location and width of the incision. Then femtosecond laser was used to make corneal releasing incision, the main and auxiliary incision. Phacoemulsification and aspheric multifocal intraocular lens implantation were undergone. Patients in conventional group received full-thickness relaxing incision by cornea paracentesis knife at the steepest meridian axis during phacoemulsification. Then aspheric multifocal intraocular lenses were implanted. Uncorrected distance visual acuity(UCDVA, uncorrected near visual acuity(UCNVAand cornea astigmatism were observed at 1d,1wk and 1mo postoperative. RESULTS:UCVA of patients in both groups was improved after the surgeries. UCDVA and UCNVA of femtosecond group were higher than those of conventional group, while the cornea astigmatism of femtosecond group was lower than that of conventional group.CONCLUSION:Refractile cataract surgery assisted by femtosecond laser canoffer better visual quality than conventional refractive cataract surgery because of lower cornea astigmatism and better visual acuity.

  16. Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery

    Science.gov (United States)

    Moshirfar, Majid; McCaughey, Michael V; Santiago-Caban, Luis

    2015-01-01

    Postoperative residual refractive error following cataract surgery is not an uncommon occurrence for a large proportion of modern-day patients. Residual refractive errors can be broadly classified into 3 main categories: myopic, hyperopic, and astigmatic. The degree to which a residual refractive error adversely affects a patient is dependent on the magnitude of the error, as well as the specific type of intraocular lens the patient possesses. There are a variety of strategies for resolving residual refractive errors that must be individualized for each specific patient scenario. In this review, the authors discuss contemporary methods for rectification of residual refractive error, along with their respective indications/contraindications, and efficacies. PMID:25663845

  17. Predicting Refractive Surgery Outcome: Machine Learning Approach With Big Data.

    Science.gov (United States)

    Achiron, Asaf; Gur, Zvi; Aviv, Uri; Hilely, Assaf; Mimouni, Michael; Karmona, Lily; Rokach, Lior; Kaiserman, Igor

    2017-09-01

    To develop a decision forest for prediction of laser refractive surgery outcome. Data from consecutive cases of patients who underwent LASIK or photorefractive surgeries during a 12-year period in a single center were assembled into a single dataset. Training of machine-learning classifiers and testing were performed with a statistical classifier algorithm. The decision forest was created by feature vectors extracted from 17,592 cases and 38 clinical parameters for each patient. A 10-fold cross-validation procedure was applied to estimate the predictive value of the decision forest when applied to new patients. Analysis included patients younger than 40 years who were not treated for monovision. Efficacy of 0.7 or greater and 0.8 or greater was achieved in 16,198 (92.0%) and 14,945 (84.9%) eyes, respectively. Efficacy of less than 0.4 and less than 0.5 was achieved in 322 (1.8%) and 506 (2.9%) eyes, respectively. Patients in the low efficacy group (differences compared with the high efficacy group (≥ 0.8), yet were clinically similar (mean differences between groups of 0.7 years, of 0.43 mm in pupil size, of 0.11 D in cylinder, of 0.22 logMAR in preoperative CDVA, of 0.11 mm in optical zone size, of 1.03 D in actual sphere treatment, and of 0.64 D in actual cylinder treatment). The preoperative subjective CDVA had the highest gain (most important to the model). Correlations analysis revealed significantly decreased efficacy with increased age (r = -0.67, P big data from refractive surgeries may be of interest. [J Refract Surg. 2017;33(9):592-597.]. Copyright 2017, SLACK Incorporated.

  18. Long-Term Changes in Refractive Error and Clinical Evaluation in Partially Accommodative Esotropia after Surgery.

    Directory of Open Access Journals (Sweden)

    Shin Yeop Oh

    Full Text Available We investigate the changes in refractive error and clinical evaluation in partially accommodative esotropia(PAET after surgery. A total of 68 patients PAET who received at least 2 years of follow-up after surgery were enrolled in this study. We performed a retrospective study in patients who underwent unilateral or bilateral medial rectus recession for a non-accommodative component of PAET between January 2005 and March 2013. Patients were divided into groups according to the presence of dominancy (dominant, non-dominant, alternative eye, and presence of amblyopia (amblyopic, fellow, normal eye. Changes and changing pattern in SE refractive error were analyzed in all patients and compared between groups. Patients were divided into two groups, those weaned off of hyperopic glasses and those who continued using them, then factors that significantly influenced the continued use of glasses were analyzed. The changes and changing pattern in SE refractive error according to time after operation and presence of amblyopia or dominancy. The mean length of follow-up was 4.89±1.74 years after surgery and the mean change in SE refractive error rate per year was -0.284±0.411 diopters (D. The pattern of changes in the mean SE refractive error for those with dominant, non-dominant, and alternative eyes was not significantly different (p = 0.292. The pattern of changes in the mean SE refractive error for those with amblyopic, fellow, and normal eyes was significantly different (p = 0.0002. Patients were successfully weaned off of hyperopic glasses at an average age of 9.41±2.74 years. The average SE refractive error in the group weaned off of hyperopic glasses was significantly lower than that in the group maintained on hyperopic glasses (p = 0.0002. The change of SE refractive error in amblyopic eyes decreased less than that in fellow or normal eyes, which may be correlated with the presence of amblyopia. Patients with a smaller esodeviated angle without

  19. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    Directory of Open Access Journals (Sweden)

    Xinjie Mao

    Full Text Available To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor.Twenty-eight adult subjects (32 pseudophakic eyes having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR and intraclass correlation coefficient (ICC were calculated.Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951.The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  20. Development of a subjective refraction simulator

    Science.gov (United States)

    Perches, S.; Ares, J.; Collados, M. V.

    2013-11-01

    We have developed simulation software by Matlab (MathworksInc.) with a graphical interface designed for non-expert users. This simulator allows you to complete the process of subjective refraction starting from the aberrometry of the patients and analyse the influence of different factors during the exam. In addition to explain the graphical interface and its working, we show two examples about a complete process of subjective refraction with the influence of high order aberrations and without them showing the retinal image obtained in each step of the refraction process. When the Jackson Cross-Cylinder technique is made with this software, it becomes clear the difficulty of chosen between two images when high order aberrations are present. Therefore, the variability of response during the refraction can be a problem when the examiner has to reach an adequate optical prescription.

  1. Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses.

    Science.gov (United States)

    Marcos, Susana; Rosales, Patricia; Llorente, Lourdes; Jiménez-Alfaro, Ignacio

    2007-02-01

    To study the effect of cataract surgery through 3.2 mm superior incisions on corneal aberrations with 2 types of monofocal intraocular lenses (IOLs) with an aspherical design. Instituto de Optica, Consejo Superior de Investigaciones Científicas, and Fundación Jiménez Díaz, Madrid, Spain. Corneal topography of 43 eyes was obtained before and after small corneal incision cataract surgery. Twenty-two eyes had implantation of a Tecnis Z9000 silicone IOL (Advanced Medical Optics) and 21 had implantation of an AcrySof IQ SN60WF acrylic IOL (Alcon Research Labs) using the recommended injector for each IOL type. The intended incision size (3.2 mm) was similar in the 2 groups. Corneal aberrations were estimated using custom-developed algorithms (based on ray tracing) for 10.0 mm and 5.0 mm pupils. Comparisons between preoperative and postoperative measurements and across the groups were made for individual Zernike terms and root-mean-square (RMS) wavefront error. The RMS (excluding tilt and defocus) did not change in the AcrySof IQ group and increased significantly in the Tecnis group with the 10.0 mm and 5.0 mm pupil diameters. Spherical aberration and coma-like terms did not change significantly; however, vertical astigmatism, vertical trefoil, and vertical tetrafoil changed significantly with surgery with the 10.0 mm and 5.0 mm pupil diameters (Porder aberrations consistently showed a superior lobe, resulting from a combination of positive vertical trefoil (Z(3)(-3)) and negative tetrafoil (Z(4)(4)). The mean vertical astigmatism increased by 2.47 microm +/- 1.49 (SD) and 1.74 +/- 1.44 microm, vertical trefoil increased by 1.81 +/- 1.19 microm and 1.20 +/- 1.34 microm, and tetrafoil increased by -1.10 +/- 0.78 microm and -0.89 +/- 0.68 microm in the Tecnis group and AcrySof IQ group, respectively. There were no significant differences between the corneal aberrations in the 2 postoperative groups, although there was a tendency toward more terms or orders changing

  2. Effect of diquafosol three per cent ophthalmic solution on tear film and corneal aberrations after cataract surgery.

    Science.gov (United States)

    Lee, Hun; Kim, Sang Myung; Choi, Seonghee; Seo, Kyoung Yul; Kim, Eung Kweon; Kim, Tae-Im

    2017-11-01

    The aim was to evaluate the effect of diquafosol on tear film parameters and corneal aberrations after cataract surgery. This retrospective, comparative, observational case series included patients who underwent cataract surgery with or without peri-operative use of diquafosol three per cent ophthalmic solution. Patients in group I (31 eyes) were treated with diquafosol three per cent ophthalmic solution six times a day from one week before surgery to three months after surgery. Patients in group II (33 eyes) underwent cataract surgery without being administered diquafosol. Tear film break-up time (BUT), the ocular surface disease index (OSDI), the Oxford Scheme score, Schirmer's test I and corneal aberrations were determined before and at one and three months post-surgery. In group I, the BUT, OSDI and Oxford Scheme score showed significant improvement at one and three months post-surgery (p = 0.002 for BUT at one month and three months, p = 0.023 and p = 0.049 for OSDI at one month and three months and p = 0.001 and p = 0.026 for Oxford Scheme at one month and three months), compared to baseline. In group II, the BUT, OSDI and Oxford Scheme score did not show any significant improvement during the follow-up period. In both groups, Schirmer's test I significantly decreased at three months post-surgery (p = 0.011 for group I and p = 0.034 for group II), compared to baseline. There were significant differences in the BUT and OSDI between the groups at three months post-surgery (p = 0.037 for BUT and p = 0.011 for OSDI). Regarding the corneal aberration, there were no significant differences between the groups at three months post-surgery. Peri-operative application of diquafosol three per cent ophthalmic solution may prevent dry eye-related ocular surface changes accompanied by improvement of ocular symptom. No definite changes in corneal aberrations were noted. © 2017 Optometry Australia.

  3. Visual and refractive outcomes following myopic laser-assisted subepithelial keratectomy with a flying-spot excimer laser.

    Science.gov (United States)

    McAlinden, Colm; Skiadaresi, Eirini; Moore, Jonathan E

    2011-05-01

    To investigate the visual and refractive outcomes following laser-assisted subepithelial keratectomy (LASEK) surgery with a flying-spot excimer laser. Private practice, Ireland. Case series. In this prospective study, the mean manifest spherical equivalent (SE), sphere, and cylinder were measured preoperatively. All eyes had LASEK surgery with an aberration-free algorithm with the Schwind Amaris excimer laser. Outcomes measured at 1 month, 6 months, and 1 year were uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity, contrast sensitivity, aberrometry, and complications. Accuracy, efficacy, and safety were evaluated at 1 year. Preoperatively, the mean SE, sphere, and cylinder in the 80 eyes (48 patients) were -3.58 diopters (D) ± 2.00 (SD), -3.23 ± 1.93 D, and -0.85 ± 0.65 D, respectively. One year postoperatively, the mean SE was -0.00 ± 0.22 D; 57 eyes (71%) were within -0.13 to +0.13 D of the SE, and 71 eyes (98%) were within ±0.50 D. The mean UDVA was -0.06 ± 0.07 logMAR, with an efficacy index of 1.04. The postoperative SE was stable between 1 month, 3 months, and 1 year. One eye (1%) had a change in SE by more than 0.50 D at 6 months and 1 year. There were no statistically significant differences in any aberrations at 1 year. The contrast sensitivity improved from 1.66 ± 0.17 log units preoperatively to 1.72 ± 0.15 log units at 1 month postoperatively (P=.0003), which was unchanged at 6 months and 1 year. This study demonstrated the effectiveness of LASEK for the treatment of myopia with this flying-spot excimer laser. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. Comparison of wavefront aberrations under cycloplegic, scotopic and photopic conditions using WaveScan

    Directory of Open Access Journals (Sweden)

    Rong Fan

    2012-04-01

    wavefront aberrations is feasible for the wavefront-guided refractive surgery.

  5. Role of the treating surgeon in the consent process for elective refractive surgery

    Directory of Open Access Journals (Sweden)

    Schallhorn SC

    2016-11-01

    Full Text Available Steven C Schallhorn,1–3 Stephen J Hannan,3 David Teenan,3 Julie M Schallhorn1 1Department of Ophthalmology, University of California, San Francisco, San Francisco, 2Roski Eye Institute, University of Southern California, Los Angeles, CA, USA; 3Optical Express, Glasgow, UK Purpose: To compare patient’s perception of consent quality, clinical and quality-of-life outcomes after laser vision correction (LVC and refractive lens exchange (RLE between patients who met their treating surgeon prior to the day of surgery (PDOS or on the day of surgery (DOS. Design: Retrospective, comparative case series. Setting: Optical Express, Glasgow, UK. Methods: Patients treated between October 2015 and June 2016 (3972 LVC and 979 RLE patients who attended 1-day and 1-month postoperative aftercare and answered a questionnaire were included in this study. All patients had a thorough preoperative discussion with an optometrist, watched a video consent, and were provided with written information. Patients then had a verbal discussion with their treating surgeon either PDOS or on the DOS, according to patient preference. Preoperative and 1-month postoperative visual acuity, refraction, preoperative, 1-day and 1-month postoperative questionnaire were compared between DOS and PDOS patients. Multivariate regression model was developed to find factors associated with patient’s perception of consent quality. Results: Preoperatively, 8.0% of LVC and 17.1% of RLE patients elected to meet their surgeon ahead of the surgery day. In the LVC group, 97.5% of DOS and 97.2% of PDOS patients indicated they were properly consented for surgery (P=0.77. In the RLE group, 97.0% of DOS and 97.0% of PDOS patients stated their consent process for surgery was adequate (P=0.98. There was no statistically significant difference between DOS and PDOS patients in most of the postoperative clinical or questionnaire outcomes. Factors predictive of patient’s satisfaction with consent quality

  6. Endothelial cell loss and refractive predictability in femtosecond laser-assisted cataract surgery compared with conventional cataract surgery

    DEFF Research Database (Denmark)

    Krarup, Therese; Holm, Lars Morten; la Cour, Morten

    2014-01-01

    and the contralateral eye operated by CPS (stop and chop technique). Both eyes had intraocular aspheric lenses implanted. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), central corneal endothelial cell count and hexagonality with a non-contact specular microscope were assessed......PURPOSE: To investigate the amount of endothelial cell loss (ECL) and refractive predictability by femtosecond laser-assisted cataract surgery (FLACS) compared to conventional phacoemulsification cataract surgery (CPS). METHODS: Forty-seven patients had one eye operated by FLACS...

  7. Keratocyte apoptosis and corneal antioxidant enzyme activities after refractive corneal surgery.

    Science.gov (United States)

    Bilgihan, K; Bilgihan, A; Adiguzel, U; Sezer, C; Yis, O; Akyol, G; Hasanreisoglu, B

    2002-01-01

    Refractive corneal surgery induces keratocyte apoptosis and generates reactive oxygen radicals (ROS) in the cornea. The purpose of the present study is to evaluate the correlation between keratocyte apoptosis and corneal antioxidant enzyme activities after different refractive surgical procedures in rabbits. Rabbits were divided into six groups. All groups were compared with the control group (Group 1), after epithelial scraping (Group 2), epithelial scrape and photorefractive keratectomy (PRK) (traditional PRK: Group 3), transepithelial PRK (Group 4), creation of a corneal flap with microkeratome (Group 5) and laser-assisted in situ keratomileusis (LASIK, Group 6). Terminal deoxyribonucleotidyl transferase-mediated dUTP-digoxigenin nick-end labelling assay (to detect DNA fragmentation in situ) and light microscopy were used to detect apoptosis in rabbit eyes. Glutathione peroxidase (Gpx) and superoxide dismutase (SOD) activities of the corneal tissues were measured with spectrophotometric methods. Corneal Gpx and SOD activities decreased significantly in all groups when compared with the control group (P<0.05) and groups 2, 3 and 6 showed a significantly higher amount of keratocyte apoptosis (P<0.05). Not only a negative correlation was observed between corneal SOD activity and keratocyte apoptosis (cc: -0.3648) but Gpx activity also showed negative correlation with keratocyte apoptosis (cc: -0.3587). The present study illustrates the negative correlation between keratocyte apoptosis and corneal antioxidant enzyme activities. This finding suggests that ROS may be partly responsible for keratocyte apoptosis after refractive surgery.

  8. Ocular higher-order aberrations in a school children population

    Directory of Open Access Journals (Sweden)

    George Papamastorakis

    2015-04-01

    Conclusions: Differences in the low levels of ocular spherical aberration in young children possibly reflect differences in lenticular spherical aberration and relate to the gradient refractive index of the lens. The evaluation of spherical aberration at certain stages of eye growth may help to better understand the underlying mechanisms of myopia development.

  9. Camera processing with chromatic aberration.

    Science.gov (United States)

    Korneliussen, Jan Tore; Hirakawa, Keigo

    2014-10-01

    Since the refractive index of materials commonly used for lens depends on the wavelengths of light, practical camera optics fail to converge light to a single point on an image plane. Known as chromatic aberration, this phenomenon distorts image details by introducing magnification error, defocus blur, and color fringes. Though achromatic and apochromatic lens designs reduce chromatic aberration to a degree, they are complex and expensive and they do not offer a perfect correction. In this paper, we propose a new postcapture processing scheme designed to overcome these problems computationally. Specifically, the proposed solution is comprised of chromatic aberration-tolerant demosaicking algorithm and post-demosaicking chromatic aberration correction. Experiments with simulated and real sensor data verify that the chromatic aberration is effectively corrected.

  10. Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates

    Directory of Open Access Journals (Sweden)

    Zofia Pniakowska

    2016-01-01

    Full Text Available Context: Subclinical keratoconus is contraindication to refractive surgery. The currently used methods of preoperative screening do not always allow differentiating between healthy eyes and those with subclinical keratoconus. Aim: To evaluate biomechanical parameters of the cornea, waveform score (WS, and intraocular pressure (IOP as potentially useful adjuncts to the diagnostic algorithm for precise detection of the early keratoconus stages and selection of refractive surgery candidates. Settings and Design: Department of Ophthalmology and prospective cross-sectional study. Patients and Methods: Patients enrolled in the study were diagnosed with refractive disorders. We assessed parameters of corneal biomechanics such as corneal hysteresis (CH, corneal resistance factor (CRF, Goldman-correlated IOP (IOPg, corneal compensated IOP, WS, and keratoconus match index (KMI. They were classified into one of three groups based on the predefined KMI range: Group 1 (from 0.352 to 0.757 – 45 eyes, Group 2 (from −0.08 to 0.313 – 52 eyes, and Group 0 - control group (from 0.761 to 1.642 – 80 eyes. Results: In both study groups, IOPg, CRF, and CH were decreased when compared to control (P < 0.0001. In control group, there was positive correlation between CH and KMI (P < 0.05, with no correlations in any of the two study groups. CRF correlated positively with KMI in control (P < 0.0001 and in Group 2 (P < 0.05. Conclusions: CH and CRF, together with WS and IOPg, consist a clinically useful adjunct to detect subclinical keratoconus in patients referred for refractive surgery when based on KMI staging.

  11. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery.

    Science.gov (United States)

    Savini, Giacomo; Hoffer, Kenneth J; Barboni, Piero

    2015-04-01

    To evaluate the possible influence of anterior corneal surface asphericity on the refractive outcomes in eyes having intraocular lens (IOL) implantation after cataract surgery. Fondazione G.B. Bietti IRCCS, Rome, Italy. Retrospective comparative case series. Intraocular lens power was calculated using the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas. Asphericity (Q-value) was measured at 8.0 mm with a Placido-disk corneal topographer (Keratron), a rotating Scheimpflug camera (Pentacam), and a rotating Scheimpflug camera combined with Placido-disk corneal topography (Sirius). The relationship between the error in refraction prediction (ie, difference between expected refraction and refraction measured 1 month after surgery) and the Q-value was assessed by linear regression. The same IOL model (Acrysof SA60AT) was implanted in 115 eyes of 115 consecutive patients. Regression analysis showed a statistically significant relationship between the error in refraction prediction and the Q-value with all formulas and all devices. In all cases, a more negative Q-value (prolate cornea) was associated with a myopic outcome, whereas a more positive Q-value (oblate cornea) was associated with a hyperopic outcome. The highest coefficient of determination was detected between the Hoffer Q formula and the Placido-disk corneal topographer (R(2) = 0.2630), for which the error in refraction prediction (y) was related to the Q-value (x) according to the formula y = -0.2641 + 1.4589 × x. Corneal asphericity influences the refractive outcomes of IOL implantation and should be taken into consideration when using third-generation IOL power formulas. Dr. Hoffer receives book royalties from Slack, Inc., Thorofare, New Jersey, and formula royalties from all manufacturers using the Hoffer Q formula. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. The business of refractive laser assisted cataract surgery (ReLACS).

    Science.gov (United States)

    Berdahl, John P; Jensen, Matthew P

    2014-01-01

    Refractive Laser Assisted Cataract Surgery (ReLACS) combines the femtosecond laser with other noncovered tests and services in an attempt to reduce spectacle dependence in combination with cataract surgery. Significant interest is present among ophthalmologists who are considering adopting this technology, however significant capital outlays and continuing expenses can make the decision to adopt ReLACS foreboding. We review the financial considerations of ReLACS and review the trends seen in early adopters of this technology. Recent findings have shown that ReLACS is a growing segment of cataract surgery. Most practices who have implemented the technology have broken even and have a positive outlook on the financial return of implementing the ReLACS program. The average break-even analysis point for practices is around 230 cases a year. ReLACS is growing and appears to be a financial viable approach for many practices.

  13. Correction of refractive errors

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2005-10-01

    Full Text Available Background: Spectacles and contact lenses are the most frequently used, the safest and the cheapest way to correct refractive errors. The development of keratorefractive surgery has brought new opportunities for correction of refractive errors in patients who have the need to be less dependent of spectacles or contact lenses. Until recently, RK was the most commonly performed refractive procedure for nearsighted patients.Conclusions: The introduction of excimer laser in refractive surgery has given the new opportunities of remodelling the cornea. The laser energy can be delivered on the stromal surface like in PRK or deeper on the corneal stroma by means of lamellar surgery. In LASIK flap is created with microkeratome in LASEK with ethanol and in epi-LASIK the ultra thin flap is created mechanically.

  14. Using an International Medical Advisory Board to guide clinical governance in a corporate refractive surgery model.

    Science.gov (United States)

    Vukich, John A

    2009-07-01

    To describe the role played by the International Medical Advisory Board (IMAB) in clinical and corporate governance at Optical Express, a corporate provider of refractive surgery. A review of goals, objectives, and actions of the IMAB. The IMAB has contributed to study design, data analysis, and selection of instruments and procedures. Through interactions with Optical Express corporate and clinical staff, the IMAB has supported management's effort to craft a corporate culture focused on continuous improvement in the safety and visual outcomes of refractive surgery. The IMAB has fashioned significant changes in corporate policies and procedures and has had an impact on corporate culture at Optical Express.

  15. Reasons not to select patients for corneal refractive surgery Razões para recusar candidatos à cirurgia refrativa corneana

    Directory of Open Access Journals (Sweden)

    André Luiz Parolin Ribeiro

    2002-08-01

    Full Text Available Purpose: To present how the section of Refractive Surgery of the Federal University of São Paulo assesses the candidates and the reasons to indicate for corneal refractive surgery. Methods: We examined 1626 patients. Anamnesis, complete ophthalmologic examination and corneal topography were performed in all patients. The patients spontaneously seeked evaluation at the Refractive Surgery Section by telephone without a previous screening. Reasons to refuse patients for refractive surgery were previously established by the Refractive Surgery Section. Results: Based on current technology and clinical experience, 265 patients (16.29% were refused for excimer laser corneal refractive surgery. Myopia of patients who had insufficient preoperative corneal pachymetry for the laser treatment was the main cause for refusal (51 patients. Cataract (45 patients, keratoconus (31 patients, amblyopia (21 patients, hyperopia > 5 diopters and mixed astigmatism (19 patients, presbyopia (unaware ness of the need for optical correction after the procedure; 16 patients, pupillary diameter > 5mm (9 patients, single eye (9 patients, progressive myopia (8 patients, postradial keratotomy (7 patients and low ametropia (7 patients were among the reasons for the refusal. Conclusion: Candidates for excimer laser corneal refractive surgery may present risk factors that should be known in order to avoid complications.Objetivo: O objetivo deste estudo é mostrar como o setor de Cirurgia Refrativa da Escola Paulista de Medicina da Universidade Federal de São Paulo avalia seus candidatos e quais as razões para não selecioná-los para cirurgia refrativa. Métodos: Foram examinados 1626 pacientes. Anamnese, avaliação oftalmológica completa e topografia corneana foram realizadas em todos os pacientes. Os pacientes procuraram avaliação no setor de Cirurgia Refrativa espontaneamente sem triagem prévia. Resultados: Não foram selecionados 265 pacientes (16,29% para cirurgia

  16. [Refractive precision and objective quality of vision after toric lens implantation in cataract surgery].

    Science.gov (United States)

    Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J

    2012-10-01

    To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  17. Prevalence and associations of anisometropia with spherical ametropia, cylindrical power, age, and sex in refractive surgery candidates.

    Science.gov (United States)

    Linke, Stephan J; Richard, Gisbert; Katz, Toam

    2011-09-29

    To analyze the prevalence and associations of anisometropia with spherical ametropia, astigmatism, age, and sex in a refractive surgery population. Medical records of 27,070 eyes of 13,535 refractive surgery candidates were reviewed. Anisometropia, defined as the absolute difference in mean spherical equivalent powers between right and left eyes, was analyzed for subjective (A(subj)) and cycloplegic refraction (A(cycl)). Correlations between anisometropia (>1 diopter) and spherical ametropia, cylindrical power, age, and sex, were analyzed using χ² and nonparametric Kruskal-Wallis or Mann-Whitney tests and binomial logistic regression analyses. Power vector analysis was applied for further analysis of cylindrical power. Prevalence of A(subj) was 18.5% and of A(cycl) was 19.3%. In hyperopes, logistic regression analysis revealed that only spherical refractive error (odds ratio [OR], 0.72) and age (OR, 0.97) were independently associated with anisometropia. A(subj) decreased with increasing spherical ametropia and advancing age. Cylindrical power and sex did not significantly affect A(subj). In myopes all explanatory variables (spherical power OR, 0.93; cylindrical power OR, 0.75; age OR, 1.02; sex OR, 0.8) were independently associated with anisometropia. Cylindrical power was most strongly associated with anisometropia. Advancing age and increasing spherical/cylindrical power correlated positively with increasing anisometropia in myopic subjects. Female sex was more closely associated with anisometropia. This large-scale retrospective analysis confirmed an independent association between anisometropia and both spherical ametropia and age in refractive surgery candidates. Notably, an inverse relationship between these parameters in hyperopes was observed. Cylindrical power and female sex were independently associated with anisometropia in myopes.

  18. Spherical aberration correction in a scanning transmission electron microscope using a sculpted thin film.

    Science.gov (United States)

    Shiloh, Roy; Remez, Roei; Lu, Peng-Han; Jin, Lei; Lereah, Yossi; Tavabi, Amir H; Dunin-Borkowski, Rafal E; Arie, Ady

    2018-06-01

    Nearly eighty years ago, Scherzer showed that rotationally symmetric, charge-free, static electron lenses are limited by an unavoidable, positive spherical aberration. Following a long struggle, a major breakthrough in the spatial resolution of electron microscopes was reached two decades ago by abandoning the first of these conditions, with the successful development of multipole aberration correctors. Here, we use a refractive silicon nitride thin film to tackle the second of Scherzer's constraints and demonstrate an alternative method for correcting spherical aberration in a scanning transmission electron microscope. We reveal features in Si and Cu samples that cannot be resolved in an uncorrected microscope. Our thin film corrector can be implemented as an immediate low cost upgrade to existing electron microscopes without re-engineering of the electron column or complicated operation protocols and can be extended to the correction of additional aberrations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Bioinspired adaptive gradient refractive index distribution lens

    Science.gov (United States)

    Yin, Kezhen; Lai, Chuan-Yar; Wang, Jia; Ji, Shanzuo; Aldridge, James; Feng, Jingxing; Olah, Andrew; Baer, Eric; Ponting, Michael

    2018-02-01

    Inspired by the soft, deformable human eye lens, a synthetic polymer gradient refractive index distribution (GRIN) lens with an adaptive geometry and focal power has been demonstrated via multilayer coextrusion and thermoforming of nanolayered elastomeric polymer films. A set of 30 polymer nanolayered films comprised of two thermoplastic polyurethanes having a refractive index difference of 0.05 were coextruded via forced-assembly technique. The set of 30 nanolayered polymer films exhibited transmission near 90% with each film varying in refractive index by 0.0017. An adaptive GRIN lens was fabricated from a laminated stack of the variable refractive index films with a 0.05 spherical GRIN. This lens was subsequently deformed by mechanical ring compression of the lens. Variation in the optical properties of the deformable GRIN lens was determined, including 20% variation in focal length and reduced spherical aberration. These properties were measured and compared to simulated results by placido-cone topography and ANSYS methods. The demonstration of a solid-state, dynamic focal length, GRIN lens with improved aberration correction was discussed relative to the potential future use in implantable devices.

  20. Sources of medical error in refractive surgery.

    Science.gov (United States)

    Moshirfar, Majid; Simpson, Rachel G; Dave, Sonal B; Christiansen, Steven M; Edmonds, Jason N; Culbertson, William W; Pascucci, Stephen E; Sher, Neal A; Cano, David B; Trattler, William B

    2013-05-01

    To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters. Copyright 2013, SLACK Incorporated.

  1. Photographic simulation of off-axis blurring due to chromatic aberration in spectacle lenses.

    Science.gov (United States)

    Doroslovački, Pavle; Guyton, David L

    2015-02-01

    Spectacle lens materials of high refractive index (nd) tend to have high chromatic dispersion (low Abbé number [V]), which may contribute to visual blurring with oblique viewing. A patient who noted off-axis blurring with new high-refractive-index spectacle lenses prompted us to do a photographic simulation of the off-axis aberrations in 3 readily available spectacle lens materials, CR-39 (nd = 1.50), polyurethane (nd = 1.60), and polycarbonate (nd = 1.59). Both chromatic and monochromatic aberrations were found to cause off-axis image degradation. Chromatic aberration was more prominent in the higher-index materials (especially polycarbonate), whereas the lower-index CR-39 had more astigmatism of oblique incidence. It is important to consider off-axis aberrations when a patient complains of otherwise unexplained blurred vision with a new pair of spectacle lenses, especially given the increasing promotion of high-refractive-index materials with high chromatic dispersion. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  2. Simulation of the Effect of Different Presbyopia-Correcting Intraocular Lenses With Eyes With Previous Laser Refractive Surgery.

    Science.gov (United States)

    Camps, Vicente J; Miret, Juan J; García, Celia; Tolosa, Angel; Piñero, David P

    2018-04-01

    To simulate the optical performance of three presbyopia-correcting intraocular lenses (IOLs) implanted in eyes with previous laser refractive surgery. A simulation of the through-focus modulation transfer function (MTF) was performed for three presbyopia-correcting IOLs (Mplus, Oculentis GmbH, Berlin, Germany; Symfony, Johnson & Johnson Vision, Santa Ana, CA; and Mini Well, SIFI S.p.A., Lavinaio, Italy) in one eye with previous myopic LASIK and another with hyperopic LASIK. Real topographic data and the wavefront aberration profile of each IOL obtained with a Hartmann-Shack sensor were used. In the eye with myopic LASIK, all IOLs lost optical quality at near and intermediate distances for 4- and 4.7-mm pupil size. For 3-mm pupil size, the Mini Well IOL showed the best intermediate and near MTF and maintained the far focus independently of the pupil. In the eye with hyperopic LASIK, the Mini Well IOL showed an intermediate, distance, and -4.00-diopter (D) foci for all pupils. The Symfony IOL showed a depth of focus at far and intermediate distance for 3-mm and a focus at -2.50 D in the rest. The Mplus showed a focus of -4.50 and -3.00 D for the 3- and 4-mm pupil, respectively. The Mini Well and Symfony IOLs seem to work better than the Mplus IOL in eyes with previous myopic LASIK. With previous hyperopic LASIK, the Mini Well IOL seems to be able to provide acceptable near, intermediate, and far foci for all pupil sizes. These findings should be confirmed in future clinical studies. [J Refract Surg. 2018;34(4):222-227.]. Copyright 2018, SLACK Incorporated.

  3. Refractive surgery for accommodative esotropia: 5-year follow-up.

    Science.gov (United States)

    Magli, Adriano; Forte, Raimondo; Gallo, Flavio; Carelli, Roberta

    2014-02-01

    To assess the long-term effectiveness and safety of refractive surgery with LASIK or photorefractive keratectomy (PRK) for treating accommodative esotropia in adults. All patients with accommodative esotropia treated with LASIK or PRK until December 2007 and with a minimum follow-up of 5 years were retrospectively included. LASIK was performed on 44 eyes of 22 patients (12 women, 10 men; mean age: 22.7 ± 2.9 years). Mean postoperative follow-up was 62.1 ± 3.2 months. PRK was performed on 16 eyes of 8 patients (4 women, 4 men; mean age: 23.7 ± 1.7 years). Mean postoperative follow-up was 61.3 ± 2.8 months. At the 5-year follow-up, the mean cycloplegic refraction was more hyperopic in the PRK group (0.3 ± 0.8 vs 0.06 ± 0.3 diopters, P = .01). Correction of esotropia to esophoria or orthotropia was present in 21 patients (95.4%) treated with LASIK and in all patients treated with PRK. Both LASIK and PRK were effective in the long-term reduction of accommodative esotropia. Copyright 2014, SLACK Incorporated.

  4. The effect of humidity and temperature on visual outcomes after myopic corneal laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Hood CT

    2016-11-01

    Full Text Available Christopher T Hood,1 Roni M Shtein,1 Daniel Veldheer,1,2 Munira Hussain,1 Leslie M Niziol,1 David C Musch,1,3 Shahzad I Mian1 1Department of Ophthalmology and Visual Sciences, University of Michigan W.K. Kellogg Eye Center, Ann Arbor, MI, 2Department of Anesthesiology, Medical College of Wisconsin, Milwaukee, WI, 3Department of Epidemiology, University of Michigan, Ann Arbor, MI, USA Objective: To determine whether procedure room environmental conditions are associated with outcomes after myopic laser in situ keratomileusis (LASIK or laser-assisted keratomileusis (LASEK. Design: Retrospective chart review. Participants: Eight hundred sixty-three eyes of 458 consecutive patients at a university-based academic practice. Methods: We reviewed the medical records of consecutive patients who underwent LASIK or LASEK over a 3-year period. Linear mixed regression models were used to investigate the association of laser room temperature and humidity with the outcomes of visual acuity and postoperative manifest spherical equivalent refraction. Repeated measures logistic regression models were used for the outcomes of diffuse lamellar keratitis (DLK and need for enhancement surgery. Results: Subjects were on an average 38.6 years old at the time of surgery (standard deviation [SD] =10.3 and the average spherical equivalent refraction of eyes was 3.8 diopters (SD =2.03. Regression models did not reveal a significant association between temperature and uncorrected distance visual acuity (UDVA or corrected distance visual acuity (CDVA, or between humidity and UDVA (P>0.05 for all. However, increased humidity was associated with a small but statistically significant improvement in CDVA after LASIK at 1 day, 1 month, 3 months, and 1 year postoperatively (P<0.05 for all. There was no significant association between temperature and humidity and the need for enhancement, the incidence of DLK, or postoperative manifest refraction. Conclusion: While increased laser

  5. Visual and refractive outcomes with ReLEx® SMILE in 600 eyes

    Directory of Open Access Journals (Sweden)

    Sri Ganesh

    2016-02-01

    Full Text Available AIM:To study the outcomes of ReLEx® small incision lenticule extraction(SMILEfor correction of myopia or myopic astigmatism in terms of visual acuity, contrast sensitivity, aberrations, and dry eye.METHODS: In this prospective, non-randomized clinical study, done at Nethradhama Super Speciality Eye Hospital, a total of 600 eyes that met the inclusion criteria underwent a thorough preoperative examination, including corrected distance visual acuity(CDVA, contrast sensitivity, aberrometry, and dry eye assessment. VisuMax femtosecond laser system was used to perform SMILE. Patients were followed up on 1, 15d and 3mo. Pre and postoperative uncorrected visual acuity(UCVA, CDVA, aberrations, dry eye, and contrast sensitivity during 3mo of follow-up were recorded. Data analysis was done with the help of a computer using SPSS for Windows Software(version 17.0, SPSS, Inc., New York, USA. A paired t-test was used to test the significance of difference between quantitative variables and Yate's Chi-square test for qualitative variables. P value less than 0.05 denoted a significant relationship.RESULTS: The study enrolled 600 eyes of 305 patients, of which 10 patients underwent SMILE in 1 eye only due to anisometropia. At 3mo, 98.83% of eyes had attained a UCVA of 20/20 or better. No patient had a loss of CDVA, and 37 eyes(6.17%showed a gain in 1 line in postoperative CDVA. Postoperative induction of coma and spherical aberrations was minimal. Contrast sensitivity reduced immediate postoperatively(PP=0.43, 0.47, 0.46CONCLUSION:Our results demonstrate the high refractive accuracy and safety of ReLEx® SMILE for the treatment of myopia and myopic astigmatism. Increase in postoperative dryness and aberrations, both accepted drawbacks of any corneal refractive surgery were observed, while decrease in contrast sensitivity was insignificant at lower spatial frequencies.

  6. Linear self-focusing of continuous UV laser beam in photo-thermo-refractive glasses.

    Science.gov (United States)

    Sidorov, Alexander I; Gorbyak, Veronika V; Nikonorov, Nikolay V

    2018-03-19

    The experimental and theoretical study of continuous UV laser beam propagation through thick silver-containing photo-thermo-refractive glass is presented. It is shown for the first time that self-action of UV Gaussian beam in glass results in its self-focusing. The observed linear effect is non-reversible and is caused by the transformation of subnanosized charged silver molecular clusters to neutral state under UV laser radiation. Such transformation is accompanied by the increase of molecular clusters polarizability and the refractive index increase in irradiated area. As a result, an extended positive lens is formed in glass bulk. In a theoretical study of linear self-focusing effect, the "aberration-free" approximation was used, taking into account spatial distribution of induced absorption.

  7. A highly-sensitive label-free biosensor based on two dimensional photonic crystals with negative refraction

    Science.gov (United States)

    Malmir, Narges; Fasihi, Kiazand

    2017-11-01

    In this work, we present a novel high-sensitive optical label-free biosensor based on a two-dimensional photonic crystal (2D PC). The suggested structure is composed of a negative refraction structure in a hexagonal lattice PC, along with a positive refraction structure which is arranged in a square lattice PC. The frequency shift of the transmission peak is measured respect to the changes of refractive indices of the studied materials (the blood plasma, water, dry air and normal air). The studied materials are filled into a W1 line-defect waveguide which is located in the PC structure with positive refraction (the microfluidic nanochannel). Our numerical simulations, which are based on finite-difference time-domain (FDTD) method, show that in the proposed structure, a sensitivity about 1100 nm/RIU and a transmission efficiency more than 75% can be achieved. With this design, to the best of our knowledge, the obtained sensitivity and the transmission efficiency are one of the highest values in the reported PC label-free biosensors.

  8. Investigation of retinal damage during refractive eye surgery

    Science.gov (United States)

    Schumacher, S.; Sander, M.; Dopke, C.; Grone, A.; Ertmer, W.; Lubatschowski, H.

    2005-04-01

    Ultrashort laser pulses are increasingly used in refractive eye surgery to cut inside transparent corneal tissue. This is exploited by the fs-LASIK procedure which affords the opportunity to correct ametropia without any mechanical effects. The cutting process is caused by the optical breakdown occurring in the laser focus. During this process only a certain amount of the pulse energy is deposited into the tissue. The remaining pulse energy propagates further through the eye and interacts with the retina and the strong absorbing tissue layers behind. Therefore this investigation shall clarify if the intensity of the remaining laser pulse and the resulting temperature field can damage the retina and the surrounding tissue. Threshold values of the retinal tissue and theoretical calculations of the temperature field will be presented.

  9. An optomechanical model eye for ophthalmological refractive studies.

    Science.gov (United States)

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  10. Differences between wavefront and subjective refraction for infrared light.

    Science.gov (United States)

    Teel, Danielle F W; Jacobs, Robert J; Copland, James; Neal, Daniel R; Thibos, Larry N

    2014-10-01

    To determine the accuracy of objective wavefront refractions for predicting subjective refractions for monochromatic infrared light. Objective refractions were obtained with a commercial wavefront aberrometer (COAS, Wavefront Sciences). Subjective refractions were obtained for 30 subjects with a speckle optometer validated against objective Zernike wavefront refractions on a physical model eye (Teel et al., Design and validation of an infrared Badal optometer for laser speckle, Optom Vis Sci 2008;85:834-42). Both instruments used near-infrared (NIR) radiation (835 nm for COAS, 820 nm for the speckle optometer) to avoid correction for ocular chromatic aberration. A 3-mm artificial pupil was used to reduce complications attributed to higher-order ocular aberrations. For comparison with paraxial (Seidel) and minimum root-mean-square (Zernike) wavefront refractions, objective refractions were also determined for a battery of 29 image quality metrics by computing the correcting lens that optimizes retinal image quality. Objective Zernike refractions were more myopic than subjective refractions for 29 of 30 subjects. The population mean discrepancy was -0.26 diopters (D) (SEM = 0.03 D). Paraxial (Seidel) objective refractions tended to be hyperopically biased (mean discrepancy = +0.20 D, SEM = 0.06 D). Refractions based on retinal image quality were myopically biased for 28 of 29 metrics. The mean bias across all 31 measures was -0.24 D (SEM = 0.03). Myopic bias of objective refractions was greater for eyes with brown irises compared with eyes with blue irises. Our experimental results are consistent with the hypothesis that reflected NIR light captured by the aberrometer originates from scattering sources located posterior to the entrance apertures of cone photoreceptors, near the retinal pigment epithelium. The larger myopic bias for brown eyes suggests that a greater fraction of NIR light is reflected from choroidal melanin in brown eyes compared with blue eyes.

  11. Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy

    Directory of Open Access Journals (Sweden)

    Juan Carlos Sánchez Caballero

    2013-04-01

    Full Text Available OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.

  12. Correlations between corneal and total wavefront aberrations

    Science.gov (United States)

    Mrochen, Michael; Jankov, Mirko; Bueeler, Michael; Seiler, Theo

    2002-06-01

    Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p the corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p equals 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.

  13. Photorefractive keratectomy for visual rehabilitation of anisometropia induced by retinal detachment surgery.

    Science.gov (United States)

    Bilgihan, K; Ozdek, S C; Gürelik, G; Adigüzel, U; Onol, M; Hasanreisoglu, B

    2000-01-01

    To evaluate the efficacy of unilateral photorefractive keratectomy to correct anisometropia induced by retinal detachment surgery. Photorefractive keratectomy was performed in 10 eyes of 10 patients with anisometropia induced by previous retinal detachment surgery. The Aesculap Meditec MEL 60 excimer laser was used. Preoperative mean spherical equivalent refraction was -5.20 D. Mean postoperative spherical equivalent refraction was -0.25 D after a mean follow-up of 12.9 months. Mean preoperative spherical equivalent refraction difference between two eyes of 4.87 D was decreased to a mean 0.60 D postoperatively (t-test, P < .0001). All patients were free of anisometropic symptoms after laser surgery. Unilateral photorefractive keratectomy seems to be an effective method to correct anisometropia induced by conventional retinal detachment surgery, especially for patients with spectacle and contact lens intolerance.

  14. Aberration-free FTIR spectroscopic imaging of live cells in microfluidic devices.

    Science.gov (United States)

    Chan, K L Andrew; Kazarian, Sergei G

    2013-07-21

    The label-free, non-destructive chemical analysis offered by FTIR spectroscopic imaging is a very attractive and potentially powerful tool for studies of live biological cells. FTIR imaging of live cells is a challenging task, due to the fact that cells are cultured in an aqueous environment. While the synchrotron facility has proven to be a valuable tool for FTIR microspectroscopic studies of single live cells, we have demonstrated that high quality infrared spectra of single live cells using an ordinary Globar source can also be obtained by adding a pair of lenses to a common transmission liquid cell. The lenses, when placed on the transmission cell window, form pseudo hemispheres which removes the refraction of light and hence improve the imaging and spectral quality of the obtained data. This study demonstrates that infrared spectra of single live cells can be obtained without the focus shifting effect at different wavenumbers, caused by the chromatic aberration. Spectra of the single cells have confirmed that the measured spectral region remains in focus across the whole range, while spectra of the single cells measured without the lenses have shown some erroneous features as a result of the shift of focus. It has also been demonstrated that the addition of lenses can be applied to the imaging of cells in microfabricated devices. We have shown that it was not possible to obtain a focused image of an isolated cell in a droplet of DPBS in oil unless the lenses are applied. The use of the approach described herein allows for well focused images of single cells in DPBS droplets to be obtained.

  15. Deep Tissue Wavefront Estimation for Sensorless Aberration Correction

    Directory of Open Access Journals (Sweden)

    Ibrahimovic Emina

    2015-01-01

    Full Text Available The multiple light scattering in biological tissues limits the measurement depth for traditional wavefront sensor. The attenuated ballistic light and the background noise caused by the diffuse light give low signal to noise ratio for wavefront measurement. To overcome this issue, we introduced a wavefront estimation method based on a ray tracing algorithm to overcome this issue. With the knowledge of the refractive index of the medium, the wavefront is estimated by calculating optical path length of rays from the target inside of the samples. This method can provide not only the information of spherical aberration from the refractive-index mismatch between the medium and biological sample but also other aberrations caused by the irregular interface between them. Simulations based on different configurations are demonstrated in this paper.

  16. Index mismatch aberration correction over long working distances using spatial light modulation.

    Science.gov (United States)

    Gjonaj, Bergin; Johnson, Patrick; Bonn, Mischa; Domke, Katrin F

    2012-11-20

    For many microscopy applications, millimeters-long free working distances (LWD) are required. However, the high resolution and contrast of LWD objectives operated in air are lost when introducing glass and/or liquid with the sample. We propose to use spatial light modulation to correct for such beam aberrations caused by refractive index mismatches. Focusing a monochromatic laser beam with a 10 mm working distance air objective (50×, 0.5 NA) through air, glass, and water, we manage to restore a sharp, intense focus (FWHMLWD air objectives, extending their usage beyond applications in air.

  17. REFLECTION AND REFRACTION, VOLUME 2.

    Science.gov (United States)

    KLAUS, DAVID J.; AND OTHERS

    THIS VOLUME 2 OF A TWO-VOLUME SET PROVIDES AUTOINSTRUCTION IN PHYSICS. THE UNITS COVERED IN THIS VOLUME ARE (1) REFLECTION OF LIGHT, (2) PHOTOMETRY, (3) POLARIZATION, (4) REFRACTION OF LIGHT, (5) SNELL'S LAW, (6) LENSES, FOCUS, AND FOCAL POINTS, (7) IMAGE FORMATION, AND (8) ABERRATIONS, THE EYE, AND MAGNIFICATION. THE INTRODUCTION AND UNITS ON…

  18. Aberrant methylation of cell-free circulating DNA in plasma predicts poor outcome in diffuse large B cell lymphoma

    DEFF Research Database (Denmark)

    Sommer Kristensen, Lasse; Hansen, Jakob Werner; Kristensen, Søren Sommer

    2016-01-01

    BACKGROUND: The prognostic value of aberrant DNA methylation of cell-free circulating DNA in plasma has not previously been evaluated in diffuse large B cell lymphoma (DLBCL). The aim of this study was to investigate if aberrant promoter DNA methylation can be detected in plasma from DLBCL patients...

  19. Angle Kappa and its importance in refractive surgery

    Directory of Open Access Journals (Sweden)

    Majid Moshirfar

    2013-01-01

    Full Text Available Angle kappa is the difference between the pupillary and visual axis. This measurement is of paramount consideration in refractive surgery, as proper centration is required for optimal results. Angle kappa may contribute to MFIOL decentration and its resultant photic phenomena. Adjusting placement of MFIOLs for angle kappa is not supported by the literature but is likely to help reduce glare and haloes. Centering LASIK in angle kappa patients over the corneal light reflex is safe, efficacious, and recommended. Centering in-between the corneal reflex and the entrance pupil is also safe and efficacious. The literature regarding PRK in patients with an angle kappa is sparse but centering on the corneal reflex is assumed to be similar to centering LASIK on the corneal reflex. Thus, centration of MFIOLs, LASIK, and PRK should be focused on the corneal reflex for patients with a large angle kappa. More research is needed to guide surgeons′ approach to angle kappa.

  20. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan

    2015-11-23

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  1. Computational imaging using lightweight diffractive-refractive optics

    KAUST Repository

    Peng, Yifan; Fu, Qiang; Amata, Hadi; Su, Shuochen; Heide, Felix; Heidrich, Wolfgang

    2015-01-01

    Diffractive optical elements (DOE) show great promise for imaging optics that are thinner and more lightweight than conventional refractive lenses while preserving their light efficiency. Unfortunately, severe spectral dispersion currently limits the use of DOEs in consumer-level lens design. In this article, we jointly design lightweight diffractive-refractive optics and post-processing algorithms to enable imaging under white light illumination. Using the Fresnel lens as a general platform, we show three phase-plate designs, including a super-thin stacked plate design, a diffractive-refractive-hybrid lens, and a phase coded-aperture lens. Combined with cross-channel deconvolution algorithm, both spherical and chromatic aberrations are corrected. Experimental results indicate that using our computational imaging approach, diffractive-refractive optics is an alternative candidate to build light efficient and thin optics for white light imaging.

  2. Parabolic refractive X-ray lenses: a breakthrough in X-ray optics

    CERN Document Server

    Lengeler, B; Benner, B; Guenzler, T F; Kuhlmann, M; Tümmler, J; Simionovici, A S; Drakopoulos, M; Snigirev, A; Snigireva, I

    2001-01-01

    Refractive X-ray lenses, considered for a long time as unfeasible, have been realized with a rotational parabolic profile at our institute: The main features of the new lenses are: they focus in two directions and are free of spherical aberration. By varying the number of individual lenses in the stack the focal length can be chosen in a typical range from 0.5 to 2 m for photon energies between about 6 and 60 keV. The aperture of the lens is about 1 mm matching the angular divergence of undulator beams at 3d generation synchrotron radiation sources. They cope without problems with the heat load from the white beam of an undulator. Finally, they are easy to align and to operate. Refractive X-ray lenses can be used with hard X-rays in the same way as glass lenses can be used for visible light, if it is take into account that the numerical aperture is small (of the order 10 sup - sup 4). Being high-quality optical elements, the refractive X-ray lenses can be used for generating a focal spot in the mu m range wit...

  3. Comparison of the characteristics in hen and quail corneas as experimental models of refractive surgery.

    Science.gov (United States)

    Gonçalves, G C; Pérez-Merino, P; Martínez-García, M C; Barcía, A; Merayo-Loves, J

    2016-07-01

    To compare the histological, morphological and the biophysical measurements between hen and quail corneas, in order to determine which of them were better suited for use as an animal model for research into corneal refractive surgery. A study was performed using the biophysical measurements of the cornea (curvature, thickness, refraction, and axial length) of 20 animals (10 hens and 10 quails). The corneas were then prepared for histological analysis under microscopy light. The analysis showed that both groups have the same number of corneal layers as the human cornea and with an evident Bowman's layer. The thickness of the hen cornea and axial length of the eye, 225.3±18.4μm and 12.8±0.25mm, respectively, were larger than that of the quail (Phen central cornea, 3.65±0.08mm, was greater than that for the quail (Ppower of each cornea was similar. The proportion of total corneal thickness of the hen stroma, 82.6%, was more similar to that of the human than was the quail stroma, 72.5%. Within the hen stroma, the density of keratocytes, 8.57±1.49 per 5,000μm(2), was about half that in the quail stroma (Phen cornea, the stromal thickness and proportional similarity of the corneal layers with human cornea, the hen maybe better than the quail as an alternative species suitable for use in studies of corneal refractive surgery. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  4. Quality of vision in refractive and cataract surgery, indirect measurers: review article.

    Science.gov (United States)

    Parede, Taís Renata Ribeira; Torricelli, André Augusto Miranda; Mukai, Adriana; Vieira Netto, Marcelo; Bechara, Samir Jacob

    2013-01-01

    Visual acuity is the measurement of an individual's ability to recognize details of an object in a space. Visual function measurements in clinical ophthalmology are limited by factors such as maximum contrast and so it might not adequately reflect the real vision conditions at that moment as well as the subjective aspects of the world perception by the patient. The objective of a successful vision-restoring surgery lies not only in gaining visual acuity lines, but also in vision quality. Therefore, refractive and cataract surgeries have the responsibility of achieving quality results. It is difficult to define quality of vision by a single parameter, and the main functional-vision tests are: contrast sensitivity, disability glare, intraocular stray light and aberrometry. In the current review the different components of the visual function are explained and the several available methods to assess the vision quality are described.

  5. Increasing the number and signal-to-noise ratio of OBS traces with supervirtual refraction interferometry and free-surface multiples

    KAUST Repository

    Bharadwaj, P.; Wang, X.; Schuster, Gerard T.; McIntosh, K.

    2013-01-01

    The theory of supervirtual interferometry is modified so that free-surface related multiple refractions can be used to enhance the signal-to-noise ratio (SNR) of primary refraction events by a factor proportional to√Ns, where Ns is the number of post-critical sources for a specified refraction multiple. We also show that refraction multiples can be transformed into primary refraction events recorded at virtual hydrophones located between the actual hydrophones. Thus, data recorded by a coarse sampling of ocean bottom seismic (OBS) stations can be transformed, in principle, into a virtual survey with P times more OBS stations, where P is the order of the visible free-surface related multiple refractions. The key assumption is that the refraction arrivals are those of head waves, not pure diving waves. The effectiveness of this method is validated with both synthetic OBS data and an OBS data set recorded offshore from Taiwan. Results show the successful reconstruction of far-offset traces out to a source-receiver offset of 120 km. The primary supervirtual traces increase the number of pickable first arrivals from approximately 1600 to more than 3100 for a subset of the OBS data set where the source is only on one side of the recording stations. In addition, the head waves associated with the first-order free-surface refraction multiples allow for the creation of six new common receiver gathers recorded at virtual OBS station located about half way between the actual OBS stations. This doubles the number of OBS stations compared to the original survey and increases the total number of pickable traces from approximately 1600 to more than 6200. In summary, our results with the OBS data demonstrate that refraction interferometry can sometimes more than quadruple the number of usable traces, increase the source-receiver offsets, fill in the receiver line with a denser distribution of OBS stations, and provide more reliable picking of first arrivals. Apotential liability

  6. Increasing the number and signal-to-noise ratio of OBS traces with supervirtual refraction interferometry and free-surface multiples

    KAUST Repository

    Bharadwaj, P.

    2013-01-10

    The theory of supervirtual interferometry is modified so that free-surface related multiple refractions can be used to enhance the signal-to-noise ratio (SNR) of primary refraction events by a factor proportional to√Ns, where Ns is the number of post-critical sources for a specified refraction multiple. We also show that refraction multiples can be transformed into primary refraction events recorded at virtual hydrophones located between the actual hydrophones. Thus, data recorded by a coarse sampling of ocean bottom seismic (OBS) stations can be transformed, in principle, into a virtual survey with P times more OBS stations, where P is the order of the visible free-surface related multiple refractions. The key assumption is that the refraction arrivals are those of head waves, not pure diving waves. The effectiveness of this method is validated with both synthetic OBS data and an OBS data set recorded offshore from Taiwan. Results show the successful reconstruction of far-offset traces out to a source-receiver offset of 120 km. The primary supervirtual traces increase the number of pickable first arrivals from approximately 1600 to more than 3100 for a subset of the OBS data set where the source is only on one side of the recording stations. In addition, the head waves associated with the first-order free-surface refraction multiples allow for the creation of six new common receiver gathers recorded at virtual OBS station located about half way between the actual OBS stations. This doubles the number of OBS stations compared to the original survey and increases the total number of pickable traces from approximately 1600 to more than 6200. In summary, our results with the OBS data demonstrate that refraction interferometry can sometimes more than quadruple the number of usable traces, increase the source-receiver offsets, fill in the receiver line with a denser distribution of OBS stations, and provide more reliable picking of first arrivals. Apotential liability

  7. Adaptação de lentes de contato após cirurgia refrativa Contact lens fitting after refractive surgery

    Directory of Open Access Journals (Sweden)

    Adimara da Candelária Renesto

    2005-02-01

    Full Text Available OBJETIVO: Avaliar a adaptação e o uso de lente de contato em pacientes que foram submetidos à cirurgia refrativa. MÉTODOS: Foi realizado estudo retrospectivo de 53 pacientes submetidos à cirurgia refrativa, que posteriormente passaram a usar lente de contato, no período de 1999 a 2003. Foram avaliados a ametropia prévia, tipo de cirurgia realizada, refração pós-cirúrgica, equivalente esférico pós-cirurgia, ceratometria pós-operatória, curva base da lente adaptada, tipo de lente de contato adaptada, acuidade visual com óculos no pós-operatório, acuidade visual final com lente de contato, complicações e motivo da interrupção do uso. O tempo de seguimento variou de 1 mês a 84 meses (média de 42,5 meses. RESULTADOS: Dos 53 pacientes analisados, 19 pacientes foram submetidos a LASIK (Laser Assisted in Situ Keratomileusis, 29 pacientes foram submetidos à RK (ceratotomia radial, 4 pacientes foram submetidos a PRK (ceratectomia fotoablativa e em um paciente não foi possível obter o tipo de cirurgia realizado. Em 61,29% dos pacientes, (57 olhos de um total de 93, foram adaptadas lentes de contato rígidas gás-permeáveis esféricas. Houve melhora da acuidade visual em 60,21% dos casos (AV>20/40, com poucas complicações. CONCLUSÃO: Devido ao número cada vez maior de cirurgias refrativas realizadas, espera-se que aumente o número de pacientes insatisfeitos com o resultado no pós-operatório e para os quais o uso de lentes de contato venha a ser a melhor opção. A adaptação de lentes de contato pós-cirurgia refrativa exige conhecimento e dedicação e em geral tem bons resultados principalmente pela melhora da acuidade visual.PURPOSE: To evaluate the fitting and use of contact lens in patients submitted to refractive surgery. METHODS: This was a retrospective study in 53 patients submitted to refractive surgery who later started to use contact lens, from 1999 to 2003. The parameters were: previous ametropia, refractive

  8. Improving axial resolution in confocal microscopy with new high refractive index mounting media.

    Science.gov (United States)

    Fouquet, Coralie; Gilles, Jean-François; Heck, Nicolas; Dos Santos, Marc; Schwartzmann, Richard; Cannaya, Vidjeacoumary; Morel, Marie-Pierre; Davidson, Robert Stephen; Trembleau, Alain; Bolte, Susanne

    2015-01-01

    Resolution, high signal intensity and elevated signal to noise ratio (SNR) are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF), a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK) with a refractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.

  9. Improving axial resolution in confocal microscopy with new high refractive index mounting media.

    Directory of Open Access Journals (Sweden)

    Coralie Fouquet

    Full Text Available Resolution, high signal intensity and elevated signal to noise ratio (SNR are key issues for biologists who aim at studying the localisation of biological structures at the cellular and subcellular levels using confocal microscopy. The resolution required to separate sub-cellular biological structures is often near to the resolving power of the microscope. When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is often impaired by spherical aberration that may occur due to refractive index mismatches. Spherical aberration results in broadening of the point-spread function (PSF, a decrease in peak signal intensity when imaging in depth and a focal shift that leads to the distortion of the image along the z-axis and thus in a scaling error. In this study, we use the novel mounting medium CFM3 (Citifluor Ltd., UK with a refractive index of 1.518 to minimize the effects of spherical aberration. This mounting medium is compatible with most common fluorochromes and fluorescent proteins. We compare its performance with established mounting media, harbouring refractive indices below 1.500, by estimating lateral and axial resolution with sub-resolution fluorescent beads. We show furthermore that the use of the high refractive index media renders the tissue transparent and improves considerably the axial resolution and imaging depth in immuno-labelled or fluorescent protein labelled fixed mouse brain tissue. We thus propose to use those novel high refractive index mounting media, whenever optimal axial resolution is required.

  10. Corneal perforation after conductive keratoplasty with previous refractive surgery.

    Science.gov (United States)

    Kymionis, George D; Titze, Patrik; Markomanolakis, Marinos M; Aslanides, Ioannis M; Pallikaris, Ioannis G

    2003-12-01

    A 56-year-old woman had conductive keratoplasty (CK) for residual hyperopia and astigmatism. Three years before the procedure, the patient had arcuate keratotomy, followed by laser in situ keratomileusis 2 years later for high astigmatism correction in both eyes. During CK, a corneal perforation occurred in the right eye; during the postoperative examination, an iris perforation and anterior subcapsule opacification were seen beneath the perforation site. The perforation was managed with a bandage contact lens and an antibiotic-steroid ointment; it had a negative Seidel sign by the third day. The surgery in the left eye was uneventful. Three months after the procedure, the uncorrected visual acuity was 20/32 and the best corrected visual acuity 20/20 in both eyes with a significant improvement in corneal topography. Care must be taken to prevent CK-treated spots from coinciding with areas in the corneal stroma that might have been altered by previous refractive procedures.

  11. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    Science.gov (United States)

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  12. On-line pachymetry outcome of ablation in aberration free mode TransPRK.

    Science.gov (United States)

    Adib-Moghaddam, Soheil; Arba-Mosquera, Samuel; Salmanian, Bahram; Omidvari, Amir-Houshang; Noorizadeh, Farsad

    2014-01-01

    There are many independent factors that influence the outcome of refractive surgeries, consisting of patient characteristics and environmental factors. We studied the accuracy of central ablation depth compared to online pachymetry results. A total of 153 eyes that underwent TransPRK at Bina Eye Hospital, Tehran, Iran, were evaluated from November 2010 to January 2012 in a retrospective cross-sectional study. The relevant data were registered and bivariate correlations and linear regression association were investigated statistically. The mean age was 29 ± 5 years. Distribution of refractive errors was as follows: compound myopic astigmatism 123 (80.4%), simple myopia 24 (15.7%), and mixed astigmatism 6 (3.9%). Mean ambient temperature and humidity levels intraoperatively were 23.49 ± 1.16°C and 28.91 ± 6.16%, respectively. There was a significant difference (p<0.001) between the preassumed central ablation depth (131.68 ± 32.72 µm) and the net level of ablation depth (measured by online pachymetry, 168.04 ± 41.47 µm). Temperature and humidity levels were not in any statistically significant correlation with the net amount of difference found. The backward linear regression was done to reveal the association between ablation depth and several variables. This study showed that there is deviation in optical coherence pachymetry online measurements done with SCHWIND AMARIS laser. Ambient temperature and humidity levels intraoperatively do not influence the outcome. However, basic structural characteristics of patients along with change in refractive index and corneal shrinkage because of corneal dehydration are associated with the differences.

  13. Refractive corneal surgery - discharge

    Science.gov (United States)

    ... surgery. Avoid contact sports (such as boxing and football) for the first 4 weeks after surgery. DO ... herein should not be used during any medical emergency or for the diagnosis or treatment of any ...

  14. Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery

    Directory of Open Access Journals (Sweden)

    Inoue Y

    2016-12-01

    Full Text Available Yasushi Inoue, Shintarou Ochi Inoue Eye Clinic, Tamano, Okayama, Japan Purpose: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS and artificial tears (AT on higher-order aberrations (HOAs in patients with dry eye after cataract surgery. Design: This was a post hoc analysis of a previously conducted randomized clinical study. Methods: Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT, corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI] and changes in HOAs (stability index [SI] were compared within and between the two groups. Results: After 4 weeks of instillation, BUT significantly increased (P=0.001 compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group (P=0.014. Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group (P=0.018. In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern to an almost constant value (a stable pattern in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P=0.004. Conclusion: The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function. Keywords: cataract surgery, dry eye, tear film breakup time, higher-order aberrations

  15. Aberrant Free Radical Biology Is a Unifying Theme in the Etiology and Pathogenesis of Major Human Diseases

    Directory of Open Access Journals (Sweden)

    Frederick E. Domann

    2013-04-01

    Full Text Available The seemingly disparate areas of oxygen toxicity, radiation exposure, and aging are now recognized to share a common feature—the aberrant production and/or removal of biologically derived free radicals and other reactive oxygen and nitrogen species (ROS/RNS. Advances in our understanding of the effects of free radicals in biology and medicine have been, and continue to be, actively translated into clinically tractable diagnostic and therapeutic applications. This issue is dedicated to recent advances, both basic discoveries and clinical applications, in the field of free radicals in biology and medicine. As more is understood about the proximal biological targets of aberrantly produced or removed reactive species, their sensors, and effectors of compensatory response, a great deal more will be learned about the commonalities in mechanisms underlying seemingly disparate disease states. Together with this deeper understanding, opportunities will arise to devise rational therapeutic interventions to decrease the incidence and severity of these diseases and positively impact the human healthspan.

  16. [Analysis of refractive status after cataract surgery in age-related cataract patients with shallow anterior chamber].

    Science.gov (United States)

    Yang, Fei; Hou, Xianru; Wu, Huijuan; Bao, Yongzhen

    2014-02-01

    To evaluate the characteristics of postoperative refractive status in age-related cataract patients with shallow anterior chamber and the correlation between pre-operative anterior chamber depth and postoperative refractive status. Prospective case-control study. Sixty-eight cases (90 eyes) with age-related cataract were recruited from October 2010 to January 2012 in People's Hospital Peking University including 28 cases (34 eyes) in control group and 40 cases (56 eyes) in shallow anterior chamber group according to anterior chamber depth (ACD) measured by Pentacam system. Axial length and keratometer were measured by IOL Master and intraocular lens power was calculated using SRK/T formula. Postoperative refraction, ACD and comprehensive eye examination were performed at 1 month and 3 months after cataract surgery. Using SPSS13.0 software to establish a database, the two groups were compared with independent samples t-test and correlation analysis were performed with binary logical regression. The postoperative refractive deviation at 1 month were (-0.39 ± 0.62) D in control group and (+0.73 ± 0.26) D in shallow anterior chamber group respectively which present statistical significance between the two groups (P = 0.00, t = 3.67); the postoperative refractive deviation in 3 month was (-0.37 ± 0.62) D in control group and (+0.79 ± 0.28) D in shallow anterior chamber group operatively which present statistical significance between the two groups (P = 0.00, t = 3.33). In shallow anterior chamber group, with the shallower of ACD, the greater of refractive deviation (P = 0.00, r1 month = -0.57, r3 months = -0.61). Hyperopic shift existed in age-related cataract patients with shallow anterior chamber and the shallower of ACD was, the greater of hyperopic shift happened.

  17. [Impact of an Aspherical Aberration Correcting Monofocal Intraocular Lens on Patient Satisfaction for Daily Life Activities: The Heidelberg Daily Task Evaluation (DATE) Questionnaire].

    Science.gov (United States)

    Kretz, F T A; Son, H; Liebing, S; Tandogan, T; Auffarth, G U

    2015-08-01

    A clinical evaluation of the functional results and its impact on daily activities of an aspherical, aberration correcting intraocular lens (IOL) was undertaken. Twenty-one patients aged from 50 to 83 years underwent cataract surgery with implantation of the aspheric IOL (Tecnis ZCB00, Abbott Medical Optics). They were evaluated 2 to 4 months after surgery for their subjective satisfaction of vision quality and its impact on performance of daily activities as well as functional results and refractive outcome. Patients were asked to fill out a questionnaire - the Heidelberg DATE (DAily Tasks Evaluation) questionnaire. Significant changes from pre- to postoperative results were found in refraction (p ≤ 0.03), with a mean prediction error of + 0.21 ± 0.43 D. UDVA and CDVA improved significantly (p < 0.01), with a postoperative CDVA of 0.0 logMAR or better in 97.1 % of eyes. All patients would recommend the procedure to a relative or a friend and 93.8 % of patients reported to be satisfied with the outcome. The implantation of the aspheric IOL Tecnis ZCB00 after cataract surgery allows the restoration of visual function, providing an optimised optical quality and a high level of patient satisfaction. Georg Thieme Verlag KG Stuttgart · New York.

  18. Diffraction limit of refractive compound lens

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A compound X-ray and neutron lenses is an array of lenses with a common axis. The resolution limited by aberration and by diffraction. Diffraction limit comes from theory based on absorption aperture of the compound refractive lenses. Beam passing through transparent lenses form Airy pattern. Results of calculation of diffraction resolution limit for non-transparent X-ray and neutron lenses are discussed. (authors)

  19. Statistical characteristics of aberrations of human eyes after small incision lenticule extraction surgery and analysis of visual performance with individual eye model.

    Science.gov (United States)

    Lou, Qiqi; Wang, Yan; Wang, Zhaoqi; Liu, Yongji; Zhang, Lin; Fang, Hui

    2015-09-01

    Preoperative and postoperative wavefront aberrations of 73 myopic eyes with small incision lenticule extraction surgery are analyzed in this paper. Twenty-eight postoperative individual eye models are constructed to investigate the visual acuity (VA) of human eyes. Results show that in photopic condition, residual defocus, residual astigmatism, and higher-order aberrations are relatively small. 100% of eyes reach a VA of 0.8 or better, and 89.3% of eyes reach a VA of 1.0 or better. In scotopic condition, the residual defocus and the higher-order aberrations are, respectively, 1.9 and 8.5 times the amount of that in photopic condition, and the defocus becomes the main factor attenuating visual performance.

  20. Simulação computacional de cirurgias foto-refrativas personalizadas e precisão relacionada à ordem das aberrações ópticas Computational simulation of customized photorefractive surgery and precision of correction related to different order aberrations

    Directory of Open Access Journals (Sweden)

    Luis Alberto Vieira de Carvalho

    2007-12-01

    Full Text Available O objetivo principal deste trabalho foi o desenvolvimento e a implementação de um algoritmo para simulação de cirurgias foto-refrativas. Sabe-se que os atuais " flying-spot" lasers para cirurgia refrativa disponíveis no mercado ainda contêm limitações na correção de algumas aberrações de ordem alta. No entanto, há muito pouca informação quantitativa sobre os erros envolvidos em função da complexidade das aberrações. Aplicando-se superfícies objetivo descritas por uma série de coeficientes de Zernike e o conceito matemático de convolução, várias ablações personalizadas foram simuladas para várias aberrações, desde baixa ordem (esfero-cilíndricas até aberrações de décima ordem (como coma, aberração esférica, entre outras. Os resultados mostram que o perfil de ablação de cada pulso do laser assim como seu diâmetro são fatores críticos quando o objetivo é corrigir aberrações de alta ordem. Além disso, outras conclusões foram possíveis, como por exemplo a de que nem todas as aberrações de alta ordem induzem aos mesmos erros na ablação. Também foi possível verificar que a correção de aberrações de alta ordem nos termos radiais (como aberração esférica é bem mais difícil do que naqueles termos contendo alta frequência angular (como trefoil.PURPOSE: To develop and implement an algorithm for simulation of photorefractive surgery. It is well known that many flying-spot lasers in the market have limitations in correcting higher order aberrations, but there is little quantitative information about errors related to aberration complexity. METHODS: By applying known surfaces described by Zernike polynomials of different orders it was possible to simulate several target surfaces that may well resemble in vivo cases of refractive surgery candidates. An algorithm that uses the mathematical concept of convolution was implemented and several simulated surfaces were tested, ranging from low order

  1. Propagation of highly aberrated laser beams in nonquadratic plasma waveguides

    International Nuclear Information System (INIS)

    Feit, M.D.; Fleck, J.A. Jr.; Morris, J.R.

    1977-01-01

    The propagation of a laser beam in a plasma column several meters long with a realistic electron density distribution is examined. The electron density distribution is based on laser-beam heating at z=0, but is otherwise uncoupled to the laser beam. The aberrated nature of the resulting lenslike medium leads to essentially aperiodic beam properties, which contrast with the completely periodic properties of Gaussian beams propagating in quadratic lenslike media. The beam is nonetheless stably trapped. These aberrated-beam properties also help to stabilize the beam against axial variations in refractive index

  2. Corneal Biomechanics in Ectatic Diseases: Refractive Surgery Implications

    Science.gov (United States)

    Ambrósio, Jr, Renato; Correia, Fernando Faria; Lopes, Bernardo; Salomão, Marcella Q.; Luz, Allan; Dawson, Daniel G.; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Roberts, Cynthia J.

    2017-01-01

    Background: Ectasia development occurs due to a chronic corneal biomechanical decompensation or weakness, resulting in stromal thinning and corneal protrusion. This leads to corneal steepening, increase in astigmatism, and irregularity. In corneal refractive surgery, the detection of mild forms of ectasia pre-operatively is essential to avoid post-operative progressive ectasia, which also depends on the impact of the procedure on the cornea. Method: The advent of 3D tomography is proven as a significant advancement to further characterize corneal shape beyond front surface topography, which is still relevant. While screening tests for ectasia had been limited to corneal shape (geometry) assessment, clinical biomechanical assessment has been possible since the introduction of the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Buffalo, USA) in 2005 and the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) in 2010. Direct clinical biomechanical evaluation is recognized as paramount, especially in detection of mild ectatic cases and characterization of the susceptibility for ectasia progression for any cornea. Conclusions: The purpose of this review is to describe the current state of clinical evaluation of corneal biomechanics, focusing on the most recent advances of commercially available instruments and also on future developments, such as Brillouin microscopy. PMID:28932334

  3. Meta analysis of therapeutic effects of domestic deproteinized calf blood extract eye gel on corneal epithelial repair after laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Jian Zhang

    2018-01-01

    Full Text Available AIM: To systemically evaluate the clinical efficacy and safety of domestic deproteinized calf blood extract eye gel for corneal epithelial repair after laser refractive surgery. METHODS:We performed a comprehensive search via Pubmed, Embase, Cochrane Library, VIP Chinese Science and Technology Journal Database, CNKI and Wan Fang Chinese periodical Database for the randomized controlled trials(RCTsat home and abroad about effects of the domestic deproteinized calf blood extract eye gel for corneal epithelial repair after laser corneal refractive surgery with retrieval time from January 2007 to December 2016. According to the inclusion and exclusion criteria, 2 medical researchers independently screened documents, extracted data and evaluated the quality. Review Manager 5.3 software was used for Meta analysis. RESULTS: Seven RCTs involving 1 042 eyes, including 523 eyes in the treatment group and 519 eyes in the control group, were selected for this Meta-analysis. The results showed that the clinical efficacy in the treatment group was better than that in the control group(OR=1.81, 95%CI: 1.39~2.35; PWMD=-0.33, 95%CI: -0.45 to -0.21; PWMD=-1.26, 95%CI: -1.56 to -0.97; PCONCLUSION: The domestic deproteinized calf blood extract eye gel can relieve the patients' symptoms after laser refractive surgery, improve the corneal epithelial recovery and the efficiency of treatment. Due to the limited quality and quantity of the studies these conclusions should be further validated by more well-designed randomized double blind controlled trials.

  4. Comparison of Different Measurement Tools and Dimensional Parameters of Pterygium to Investigate its Impact on Refractive Indices and Ocular Aberrations.

    Science.gov (United States)

    Gumus, Koray; Guven, Aysegul; Altinkaynak, Miray; Keskin, Merve

    2018-03-01

    The aim of this study was to compare different measurement tools and parameters, including a new computer-assisted image processing technique for the quantitative analysis of the percentage of pterygium on the corneal surface, horizontal/vertical lengths obtained using slitlamp beam and surgical compass. A total of 21 pterygia of 17 patients were included in the study. The pterygia were measured by three different methods: a slitlamp beam, a surgical compass, and a new computer-assisted image processing method. Refractive indices and higher-order aberrations were analyzed in all cases. The new computer-assisted image processing technique revealed excellent intraclass correlation coefficients for intraobserver and interobserver reliability (0.999 and 0.995, respectively). However, horizontal and vertical lengths revealed more deviation between the measurements obtained with slitlamp beam and surgical compass. Although uncorrected visual acuity did not show any significant correlation between horizontal and vertical lengths of pterygia measured by either slitlamp beam or surgical compass, it was correlated with the digital pterygium ratio (rho, 0.462; P=0.035). All ocular aberration (total, higher-order, coma, trefoil, quatrefoil, spherical, and higher-order astigmatism) Root-mean-square values more strongly correlated with higher percentage values of pterygium that covers the cornea, measured by the new computer-assisted image processing technique. The percentage of pterygium covering the corneal surface seems to be more associated with the pterygium-related visual disturbances than with horizontal and vertical lengths measured by conventional techniques. Moreover, the new computer-assisted image processing technique can accurately and reliably measure the percentage extension of pterygium on cornea.

  5. Fluorescence microscopy point spread function model accounting for aberrations due to refractive index variability within a specimen.

    Science.gov (United States)

    Ghosh, Sreya; Preza, Chrysanthe

    2015-07-01

    A three-dimensional (3-D) point spread function (PSF) model for wide-field fluorescence microscopy, suitable for imaging samples with variable refractive index (RI) in multilayered media, is presented. This PSF model is a key component for accurate 3-D image restoration of thick biological samples, such as lung tissue. Microscope- and specimen-derived parameters are combined with a rigorous vectorial formulation to obtain a new PSF model that accounts for additional aberrations due to specimen RI variability. Experimental evaluation and verification of the PSF model was accomplished using images from 175-nm fluorescent beads in a controlled test sample. Fundamental experimental validation of the advantage of using improved PSFs in depth-variant restoration was accomplished by restoring experimental data from beads (6  μm in diameter) mounted in a sample with RI variation. In the investigated study, improvement in restoration accuracy in the range of 18 to 35% was observed when PSFs from the proposed model were used over restoration using PSFs from an existing model. The new PSF model was further validated by showing that its prediction compares to an experimental PSF (determined from 175-nm beads located below a thick rat lung slice) with a 42% improved accuracy over the current PSF model prediction.

  6. Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

    International Nuclear Information System (INIS)

    Kumari, S. Sindhu; Varadaraj, Kulandaiappan

    2014-01-01

    Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0 +/− ) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0 +/− /AQP1 +/− ) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P f ) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA. Transmission and

  7. Simultaneous versus sequential penetrating keratoplasty and cataract surgery.

    Science.gov (United States)

    Hayashi, Ken; Hayashi, Hideyuki

    2006-10-01

    To compare the surgical outcomes of simultaneous penetrating keratoplasty and cataract surgery with those of sequential surgery. Thirty-nine eyes of 39 patients scheduled for simultaneous keratoplasty and cataract surgery and 23 eyes of 23 patients scheduled for sequential keratoplasty and secondary phacoemulsification surgery were recruited. Refractive error, regular and irregular corneal astigmatism determined by Fourier analysis, and endothelial cell loss were studied at 1 week and 3, 6, and 12 months after combined surgery in the simultaneous surgery group or after subsequent phacoemulsification surgery in the sequential surgery group. At 3 and more months after surgery, mean refractive error was significantly greater in the simultaneous surgery group than in the sequential surgery group, although no difference was seen at 1 week. The refractive error at 12 months was within 2 D of that targeted in 15 eyes (39%) in the simultaneous surgery group and within 2 D in 16 eyes (70%) in the sequential surgery group; the incidence was significantly greater in the sequential group (P = 0.0344). The regular and irregular astigmatism was not significantly different between the groups at 3 and more months after surgery. No significant difference was also found in the percentage of endothelial cell loss between the groups. Although corneal astigmatism and endothelial cell loss were not different, refractive error from target refraction was greater after simultaneous keratoplasty and cataract surgery than after sequential surgery, indicating a better outcome after sequential surgery than after simultaneous surgery.

  8. Refractive error magnitude and variability: Relation to age.

    Science.gov (United States)

    Irving, Elizabeth L; Machan, Carolyn M; Lam, Sharon; Hrynchak, Patricia K; Lillakas, Linda

    2018-03-19

    To investigate mean ocular refraction (MOR) and astigmatism, over the human age range and compare severity of refractive error to earlier studies from clinical populations having large age ranges. For this descriptive study patient age, refractive error and history of surgery affecting refraction were abstracted from the Waterloo Eye Study database (WatES). Average MOR, standard deviation of MOR and astigmatism were assessed in relation to age. Refractive distributions for developmental age groups were determined. MOR standard deviation relative to average MOR was evaluated. Data from earlier clinically based studies with similar age ranges were compared to WatES. Right eye refractive errors were available for 5933 patients with no history of surgery affecting refraction. Average MOR varied with age. Children <1 yr of age were the most hyperopic (+1.79D) and the highest magnitude of myopia was found at 27yrs (-2.86D). MOR distributions were leptokurtic, and negatively skewed. The mode varied with age group. MOR variability increased with increasing myopia. Average astigmatism increased gradually to age 60 after which it increased at a faster rate. By 85+ years it was 1.25D. J 0 power vector became increasingly negative with age. J 45 power vector values remained close to zero but variability increased at approximately 70 years. In relation to comparable earlier studies, WatES data were most myopic. Mean ocular refraction and refractive error distribution vary with age. The highest magnitude of myopia is found in young adults. Similar to prevalence, the severity of myopia also appears to have increased since 1931. Copyright © 2018 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  9. Refractive regression after laser in situ keratomileusis.

    Science.gov (United States)

    Yan, Mabel K; Chang, John Sm; Chan, Tommy Cy

    2018-04-26

    Uncorrected refractive errors are a leading cause of visual impairment across the world. In today's society, laser in situ keratomileusis (LASIK) has become the most commonly performed surgical procedure to correct refractive errors. However, regression of the initially achieved refractive correction has been a widely observed phenomenon following LASIK since its inception more than two decades ago. Despite technological advances in laser refractive surgery and various proposed management strategies, post-LASIK regression is still frequently observed and has significant implications for the long-term visual performance and quality of life of patients. This review explores the mechanism of refractive regression after both myopic and hyperopic LASIK, predisposing risk factors and its clinical course. In addition, current preventative strategies and therapies are also reviewed. © 2018 Royal Australian and New Zealand College of Ophthalmologists.

  10. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    Science.gov (United States)

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  11. Preliminary study of the correlation between refractive error and corneal refractive power, corneal asphericity in myopic eye

    Directory of Open Access Journals (Sweden)

    Qi-Chao Han

    2014-05-01

    Full Text Available AIM: To investigate the correlation between myopic refractive error and relative factors, including the corneal refractive power, posterior refractive power, axial length, corneal asphericity coefficient Q value, central cornea thickness(CCTand intraocular pressure(IOP. METHODS:According to the degree of myopia measured by subjective refraction, 138 myopia patients were divided into three subgroups: mild group(-1.00D--3.00D, moderate group(-3.25D--6.00D, high group(>6.00D. The Pentacam anterior segment tomographer(Germany, Oculus Companywas used to measure the corneal refractive power, posterior refractive power, and corneal asphericity in the right eye. IOP, CCT and axial length were measured by a non-contact tonometer and A-scan ultrasonic, respectively. The data was analyzed with a Pearson correlation analysis and one-way ANOVA. RESULTS: The myopic refractive error was negatively correlated with the axial length(r=-0.682, Pr=0.009, P=0.925. The axial length was negatively correlated with corneal refractive power(r=-0.554, Pr=0.674, Pr=-0.375, P=0.01. There was no significantly correlation between the myopic refractive error and CCT, IOP(r=-0.138, P=0.141; r=-0.121, P=0.157. CONCLUSION:The corneal refractive power plays the role of emmetropization during the development of myopia. There is clinic significance for the correlation between Q value and refractive error, IOP to guide the corneal refractive surgery.

  12. Seguridad del paciente en la cirugía refractiva con láser Safety of the patients in the refractive surgery with laser

    Directory of Open Access Journals (Sweden)

    Yureisi Labarrere Cruz

    2012-06-01

    Full Text Available Objetivo: Describir aspectos relacionados con la seguridad del paciente en la cirugía refractiva con láser y enumerar las medidas para disminuir el riesgo de complicaciones. Métodos: Se realizó un estudio descriptivo transversal. El universo de estudio y la muestra se conformó por 11 720 ojos correspondientes a 5 955 pacientes que fueron intervenidos de cirugía refractiva con láser de excímeros entre los años 2005 y 2009 en el salón de cirugía refractiva del Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Los datos se presentaron en tablas y gráficos, procesados en el paquete estadístico Statgraph Plus 50. Resultados: El número de ojos operados tuvo un aumento progresivo y su mayor representación en los años 2008 y 2009 (24,5 % y 25,1 %, respectivamente. Las complicaciones representaron 0,74 % del total de ojos intervenidos y con tendencia a la disminución en el tiempo. Conclusión: Existe un aumento en la demanda de la cirugía refractiva por láser en nuestro medio para la corrección de los defectos refractivos. Es necesario cumplir un conjunto de medidas que disminuyen la presencia de complicaciones, así se brinda mayor seguridad al paciente.Objective: To Identify and to describe aspects of the patient's safety in the refractive surgery with laser, as well as the measures to reduce the risk of complications. Methods: A cross-sectional descriptive study was undertaken. The universe of study was the sample of 11 720 eyes from 5 955 patients who had undergone refractive surgery with excímer laser from 2005 to 2009 in Refractive Surgery service of ¨Ramón Pando Ferrer¨ Cuban Institute of Ophthalmology. Data was processed by Statgraph Plus 50 package and presented in charts and graphics. Results: The number of operated eyes progressively increased and the biggest figure was reached in 2008 and 2009, accounting for 24.5% and 25.1% respectively. The complications occurred in 0.74 % of the total of operated eyes, with a

  13. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    Science.gov (United States)

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  14. Parity-Time Symmetric Nonlocal Metasurfaces: All-Angle Negative Refraction and Volumetric Imaging

    Science.gov (United States)

    Monticone, Francesco; Valagiannopoulos, Constantinos A.; Alù, Andrea

    2016-10-01

    Lens design for focusing and imaging has been optimized through centuries of developments; however, conventional lenses, even in their most ideal realizations, still suffer from fundamental limitations, such as limits in resolution and the presence of optical aberrations, which are inherent to the laws of refraction. In addition, volume-to-volume imaging of three-dimensional regions of space is not possible with systems based on conventional refractive optics, which are inherently limited to plane-to-plane imaging. Although some of these limitations have been at least theoretically relaxed with the advent of metamaterials, several challenges still stand in the way of ideal imaging of three-dimensional regions of space. Here, we show that the concept of parity-time symmetry, combined with tailored nonlocal responses, enables overcoming some of these challenges, and we propose the design of a loss-immune, linear, transversely invariant, planarized metamaterial lens, with reduced aberrations and the potential to realize volume-to-volume imaging.

  15. Parity-Time Symmetric Nonlocal Metasurfaces: All-Angle Negative Refraction and Volumetric Imaging

    Directory of Open Access Journals (Sweden)

    Francesco Monticone

    2016-10-01

    Full Text Available Lens design for focusing and imaging has been optimized through centuries of developments; however, conventional lenses, even in their most ideal realizations, still suffer from fundamental limitations, such as limits in resolution and the presence of optical aberrations, which are inherent to the laws of refraction. In addition, volume-to-volume imaging of three-dimensional regions of space is not possible with systems based on conventional refractive optics, which are inherently limited to plane-to-plane imaging. Although some of these limitations have been at least theoretically relaxed with the advent of metamaterials, several challenges still stand in the way of ideal imaging of three-dimensional regions of space. Here, we show that the concept of parity-time symmetry, combined with tailored nonlocal responses, enables overcoming some of these challenges, and we propose the design of a loss-immune, linear, transversely invariant, planarized metamaterial lens, with reduced aberrations and the potential to realize volume-to-volume imaging.

  16. Resident and young physician experience with complex cataract surgery and new cataract and refractive technology: Results of the ASCRS 2016 Young Eye Surgeons survey.

    Science.gov (United States)

    Schallhorn, Julie M; Ciralsky, Jessica B; Yeu, Elizabeth

    2017-05-01

    A survey was offered to attendees of the 2016 annual meeting of the American Society of Cataract and Refractive Surgery (ASCRS) as well as online to ASCRS members. Of the 429 self-identified surgeons in training or those with fewer than 5 years in practice, 83% had performed complex cataract surgery using iris expansion devices or capsular tension rings (63%) and 70% had implanted a toric intraocular lens (IOL). A minority of respondents had performed laser-assisted cataract surgery (27%) or implanted presbyopia-correcting IOLs (39%), and only half (50%) had performed laser vision correction (LVC). Comfort with complex cataract and IOL procedures improved with increasing number of cases performed until greater than 10 cases. From this we can conclude that young surgeons have adequate exposure to complex cataracts but lack experience in refractive surgery and new IOL technology. Reported surgeon confidence improved with increased experience and exposure. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Aquaporin 0 plays a pivotal role in refractive index gradient development in mammalian eye lens to prevent spherical aberration

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, S. Sindhu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, New York, NY (United States)

    2014-10-03

    Highlights: • Intact AQP0 functions as fiber cell-to-fiber cell adhesion protein. • AQP0 facilitates reduction in extracellular space and lens water content. • AQP0 adhesion function aids in lens refractive index gradient (RING) formation. • AQP0 prevents lens spherical aberration by establishing RING. • AQP0 is critical for lens transparency and homeostasis. - Abstract: Aquaporin 0 (AQP0) is a transmembrane channel that constitutes ∼45% of the total membrane protein of the fiber cells in mammalian lens. It is critical for lens transparency and homeostasis as mutations and knockout cause autosomal dominant lens cataract. AQP0 functions as a water channel and as a cell-to-cell adhesion (CTCA) molecule in the lens. Our recent in vitro studies showed that the CTCA function of AQP0 could be crucial to establish lens refractive index gradient (RING). However, there is a lack of in vivo data to corroborate the role of AQP0 as a fiber CTCA molecule which is critical for creating lens RING. The present investigation is undertaken to gather in vivo evidence for the involvement of AQP0 in developing lens RING. Lenses of wild type (WT) mouse, AQP0 knockout (heterozygous, AQP0{sup +/−}) and AQP0 knockout lens transgenically expressing AQP1 (heterozygous AQP0{sup +/−}/AQP1{sup +/−}) mouse models were used for the study. Data on AQP0 protein profile of intact and N- and/or C-terminal cleaved AQP0 in the lens by MALDI-TOF mass spectrometry and SDS–PAGE revealed that outer cortex fiber cells have only intact AQP0 of ∼28 kDa, inner cortical and outer nuclear fiber cells have both intact and cleaved forms, and inner nuclear fiber cells have only cleaved forms (∼26–24 kDa). Knocking out of 50% of AQP0 protein caused light scattering, spherical aberration (SA) and cataract. Restoring the lost fiber cell membrane water permeability (P{sub f}) by transgene AQP1 did not reinstate complete lens transparency and the mouse lenses showed light scattering and SA

  18. Coagulase-negative staphylococci isolated from ocular wound infections after laser refractive surgery: attachment to and accumulation on soft contact lenses.

    Science.gov (United States)

    Faghri, Jamshid; Razavi, Mohamad Reza

    2009-03-01

    Disposable soft contact lenses that are commonly used after laser refractive surgery are known to be colonized by bacteria and play a key role in Bacterial Keraitis (BK) pathogenesis. Coagulase-negative staphylococci (CoNS) have been found to be the most common pathogen involved in this postoperative infection. In this study a rapid and a simple assay was developed for studying attachment and accumulation of CoNS on soft contact lenses in vitro using [3H] thymidine. Thirty-five isolates of CoNS were obtained from 27 laser refractive surgery patients. Twenty-five of these thirty-five CoNS were isolated in multiple cultures. Ten CoNS were isolated in cultures from patients who underwent reoperation. The assay was optimized using a biofilm-producing strain, S. epidermidis RP62A, which was subcultured overnight at 37 degrees C on blood agar medium. Quantitative determination of biofilm production was tested. Presence of the genes icaADB and icaD was determined in all isolates. All isolates were biochemically analyzed using the Phene Plate (PhP) system modified for typing of CoNS. The CoNS isolates were further characterized to species level using ID32Staph.Mann-Whitney rank sum test and chi-square test were used to identify statistical differences in adherence, index, antibiotic susceptibility patterns, and biofilm production or presence of the ica operon between clinically significant isolates and non-postoperative BK isolates. No differences in attachment and accumulation were found between isolates causing BK after laser refractive surgery and contaminant isolates. In addition, there were no differences in the distribution of the ica operon between the two groups, as determined by polymerase chain reaction. Nevertheless, the ability to produce biofilm was found to be present significantly more frequently among BK isolates than among non-postoperative BK isolates. This study shows that the method using radioactive thymidine to analyze adherence of CoNS to soft

  19. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    César Albarrán-Diego

    2017-11-01

    Full Text Available AIM: To evaluate the clinical utility of automated refraction (AR and keratometry (KR compared with subjective or manifest refraction (MR after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH refractive multifocal intraocular lens (IOL. METHODS: Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS: Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION: We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  20. Measurement of specimen-induced aberrations of biological samples using phase stepping interferometry.

    Science.gov (United States)

    Schwertner, M; Booth, M J; Neil, M A A; Wilson, T

    2004-01-01

    Confocal or multiphoton microscopes, which deliver optical sections and three-dimensional (3D) images of thick specimens, are widely used in biology. These techniques, however, are sensitive to aberrations that may originate from the refractive index structure of the specimen itself. The aberrations cause reduced signal intensity and the 3D resolution of the instrument is compromised. It has been suggested to correct for aberrations in confocal microscopes using adaptive optics. In order to define the design specifications for such adaptive optics systems, one has to know the amount of aberrations present for typical applications such as with biological samples. We have built a phase stepping interferometer microscope that directly measures the aberration of the wavefront. The modal content of the wavefront is extracted by employing Zernike mode decomposition. Results for typical biological specimens are presented. It was found for all samples investigated that higher order Zernike modes give only a small contribution to the overall aberration. Therefore, these higher order modes can be neglected in future adaptive optics sensing and correction schemes implemented into confocal or multiphoton microscopes, leading to more efficient designs.

  1. Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery.

    Science.gov (United States)

    Inoue, Yasushi; Ochi, Shintarou

    2017-01-01

    To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS) and artificial tears (AT) on higher-order aberrations (HOAs) in patients with dry eye after cataract surgery. This was a post hoc analysis of a previously conducted randomized clinical study. Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years) with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI]) and changes in HOAs (stability index [SI]) were compared within and between the two groups. After 4 weeks of instillation, BUT significantly increased ( P =0.001) compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group ( P =0.014). Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group ( P =0.018). In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern) to an almost constant value (a stable pattern) in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P =0.004). The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function.

  2. In vivo longitudinal chromatic aberration of pseudophakic eyes.

    Science.gov (United States)

    Siedlecki, Damian; Jóźwik, Agnieszka; Zając, Marek; Hill-Bator, Aneta; Turno-Kręcicka, Anna

    2014-02-01

    To present the results of longitudinal chromatic aberration measurements on two groups of pseudophakic eyes in comparison to healthy eyes. The longitudinal chromatic aberration of the eye, defined as chromatic difference of refraction with disabled accommodation, was measured with the use of a visual refractometer with a custom-designed target illuminator consisting of a narrow-band RGB diode (blue λb = 470 ± 15 nm; green λg = 525 ± 18 nm; red λr = 660 ± 10 nm). The measurements were performed on nine eyes implanted with AcrySof IQ SN60WF, 14 eyes implanted with AcrySof SA60AT, and 10 phakic eyes under cycloplegia. The mean values of the longitudinal chromatic aberration between 470 and 660 nm for the control group was 1.12 ± 0.14 D. For SA60AT group, it was 1.45 ± 0.42 D whereas for SN60WF it was 1.17 ± 0.52 D. The statistical test showed significant difference between SA60AT and the control group (p chromatic aberration in vivo can be easily and reliably estimated with an adapted visual refractometer. The two groups of pseudophakic eyes measured in this study showed different values of chromatic aberration. Its magnitude for SA60AT group was significantly larger than for the control group whereas for SN60WF the difference was not significant. The optical material used for intraocular lens design may have significant influence on the magnitude of the chromatic aberration of the pseudophakic eye, and therefore on its optical and visual performance in polychromatic light.

  3. Analysis of influence factors of free cataract surgery in suburban district of one city in middle China

    Directory of Open Access Journals (Sweden)

    Jian-He Xiao

    2013-09-01

    Full Text Available AIM:To investigate the reasons of the barriers to free cataract surgery in suburban area of one city in middle China. METHODS: From 2008 to 2009, in Sight Rehabilitation Programme of Cataract in suburban district of one city in middle China, all visually significant cataract patients screened were questioned about why he/she did not accept free cataract surgery. The answers were recorded and analyzed. RESULTS: Of 892 screened patients, only 387 patients(43.39%wanted a free cataract surgery at first. At last 490 patients(54.93%accepted free surgery. The main reasons for patients who did not accept free surgery include: be afraid of surgery and wanting other treatments(193, 21.64%, thinking the eyesight was enough for daily life(148, 16.59%, worrying about that the result would not be good as those paid for surgery(147, 16.48%, and other reasons(17, 1.91%.CONCLUSION: The reasons of the barriers to free cataract surgery include patients' ignorance, surgery outcome of patients around, and working mode of designated surgical hospital.

  4. Aberrant internal carotid artery in the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Keun Tak; Kang, Hyun Koo [Dept. of Radiology, Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2014-10-15

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  5. Aberrant internal carotid artery in the middle ear

    International Nuclear Information System (INIS)

    Roh, Keun Tak; Kang, Hyun Koo

    2014-01-01

    The knowledge about the aberrant internal carotid artery (ICA) in the middle ear is essential for clinicians, because a misdiagnosis of the aberrant ICA could have serious consequences such as excessive aural bleeding during a middle ear surgery. A 38-year-old woman presented with tinnitus and hearing difficulties of the left ear that had started 5 years ago. During otoscopy, an anteroinferior bluish mass was seen in the tympanic space. Computed tomography and magnetic resonance imaging demonstrated a left-side aberrant ICA with bony dehiscence of the carotid canal in the middle ear and a reduced diameter of the tympanic ICA. Herein we report a case of an aberrant ICA in the middle ear. We also review the literature regarding this important vascular anomaly of the temporal bone which may lead to disastrous surgical complications.

  6. Third-order aberration-free ion-optical system for an electromagnetic isotope separator

    International Nuclear Information System (INIS)

    Chavet, I.

    1982-12-01

    The essential qualities required of a production isotope separator are high output and high enrichment factor. For this purpose, the imaging system should have as little geometric aberration as possible. In the proposed system, consisting of a homogeneous sector-type analyzing magnet, the beam is crossed in the axial direction at the entrance boundary of the magnetic field and the incidence to this boundary is normal. It is shown that for this case all radial aberrations to the ''practical'' third order can be eliminated provided four optical conditions are satisfied: two related to heterogeneous aberration terms in addition to the two conditions related to the second and third order homogeneous aperture aberration terms. The resulting equations take into account the magnetic fringe-field effects to the third order. (author)

  7. Eye aberration analysis with Zernike polynomials

    Science.gov (United States)

    Molebny, Vasyl V.; Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.

    1998-06-01

    New horizons for accurate photorefractive sight correction, afforded by novel flying spot technologies, require adequate measurements of photorefractive properties of an eye. Proposed techniques of eye refraction mapping present results of measurements for finite number of points of eye aperture, requiring to approximate these data by 3D surface. A technique of wave front approximation with Zernike polynomials is described, using optimization of the number of polynomial coefficients. Criterion of optimization is the nearest proximity of the resulted continuous surface to the values calculated for given discrete points. Methodology includes statistical evaluation of minimal root mean square deviation (RMSD) of transverse aberrations, in particular, varying consecutively the values of maximal coefficient indices of Zernike polynomials, recalculating the coefficients, and computing the value of RMSD. Optimization is finished at minimal value of RMSD. Formulas are given for computing ametropia, size of the spot of light on retina, caused by spherical aberration, coma, and astigmatism. Results are illustrated by experimental data, that could be of interest for other applications, where detailed evaluation of eye parameters is needed.

  8. Epiretinal membrane surgery

    DEFF Research Database (Denmark)

    Hamoudi, Hassan; Correll Christensen, Ulrik; La Cour, Morten

    2017-01-01

    Purpose: To assess the impact of combined phacoemulsification-vitrectomy and sequential surgery for idiopathic epiretinal membrane (ERM) on refractive error (RE) and macular morphology. Methods: In this prospective clinical trial, we allocated phakic eyes with ERM to (1) cataract surgery and subs......Purpose: To assess the impact of combined phacoemulsification-vitrectomy and sequential surgery for idiopathic epiretinal membrane (ERM) on refractive error (RE) and macular morphology. Methods: In this prospective clinical trial, we allocated phakic eyes with ERM to (1) cataract surgery...... and achieved spherical equivalent); secondary outcomes were best-corrected visual acuity (BCVA), and incidence of cystoid macular oedema (CME) defined as >10% increment of central subfield macular thickness (CSMT). Results: Sixty-two eyes were enrolled. The mean RE showed a small myopic shift of -0.36D in all...... between the groups. Four cases (17%) in the CAT group had resolved visual complaints and improved BCVA after cataract surgery resulting in no need for PPV within the follow-up period. Conclusion: Surgery for idiopathic ERM in phakic eyes with either phaco-vitrectomy or sequential surgery are equal...

  9. Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Michael Lasta

    2017-01-01

    Full Text Available Purpose. To compare the effect of spherical aberration on optical quality in eyes with two different aspherical intraocular lenses. Methods. 120 eyes of 60 patients underwent phacoemulsification. In patients’ eyes, an aberration-free IOL (Aspira-aA; Human Optics or an aberration-correcting aspherical IOL (Tecnis ZCB00; Abott Medical Optics was randomly implanted. After surgery, contrast sensitivity and wavefront measurements as well as tilt and decentration measurements were performed. Results. Contrast sensitivity was significantly higher in eyes with Aspira lens under mesopic conditions with 12 cycles per degree (CPD and under photopic conditions with 18 CPD (p=0.02. Wavefront measurements showed a higher total spherical aberration with a minimal pupil size of 4 mm in the Aspira group (0.05 ± 0.03 than in the Tecnis group (0.03 ± 0.02 (p=0.001. Strehl ratio was higher in eyes with Tecnis (0.28 ± 0.17 with a minimal pupil size larger than 5 mm than that with Aspira (0.16 ± 0.14 (p=0.04. In pupils with a minimum diameter of 4 mm spherical aberration had a significant effect on Strehl ratio, but not in pupils with a diameter less than 4 mm. Conclusions. Optical quality was better in eyes with the aberration-correcting Tecnis IOL when pupils were large. In contrast, this could not be shown in eyes with pupils under 4 mm or larger. This trial is registered with Clinicaltrials.gov NCT03224728.

  10. Recurrent branchial sinus tract with aberrant extension.

    Science.gov (United States)

    Barret, J P

    2004-01-01

    Second branchial cysts are the commonest lesions among congenital lateral neck anomalies. Good knowledge of anatomy and embryology are necessary for proper treatment. Surgical treatment involves resection of all branchial remnants, which extend laterally in the neck, medial to the sternocleidomastoid muscle with cranial extension to the pharynx and ipsilateral tonsillar fosa. However, infections and previous surgery can distort anatomy, making the approach to branchial anomalies more difficult. We present a case of a 17-year-old patient who presented with a second branchial tract anomaly with an aberrant extension to the midline and part of the contralateral neck. Previous surgical interventions and chronic infections may have been the primary cause for this aberrant tract. All head and neck surgeons should bear in mind that aberrant presentations may exist when reoperating on chronic branchial cysts fistulas.

  11. Plasmon-negative refraction at the heterointerface of graphene sheet arrays.

    Science.gov (United States)

    Huang, He; Wang, Bing; Long, Hua; Wang, Kai; Lu, Peixiang

    2014-10-15

    We demonstrate negative refraction of surface plasmon polaritons (SPPs) at the heterointerface of two monolayer graphene sheet arrays (MGSAs) with different periods. The refraction angle is specifically related to the period ratio of the two MGSAs. By varying the incident Bloch momentum, the SPPs might be refracted in the direction normal to the heterointerface. Moreover, both positive and negative refraction could appear simultaneously. Because of the linear diffraction relation, the incident and refracted SPP beams experience diffraction-free propagation. The heterostructures composed of the MGSAs may find great applications in deep-subwavelength spatial light modulators, optical splitters, and switches.

  12. A Model of the Effect of Lens Development on Refraction in Schoolchildren.

    Science.gov (United States)

    He, Ji C

    2017-12-01

    The study provides a new theory on the mechanism underlying myopia development, and it could be useful in clinical practice to control myopia development in schoolchildren. To model the effect of the crystalline lens on refractive development in schoolchildren. The Zemax 13 was used to calculate Zernike aberrations and refractions across 50° horizontal visual fields. Optical effects of the anterior chamber depth, lens thickness, and radii of curvature of the lens surfaces on refractions were modeled. Refractive changes induced by lens development in emmetropic and myopic eyes, based on a previous longitudinal study from literature, were calculated. A lens thickness reduction with an anterior chamber depth deepening caused a hyperopic shift over the visual fields and even more at the periphery. Opposite effects were found when the lens was thinned without any change of the anterior chamber depth. While a flattening of the anterior lens surface produced hyperopic refractions overall, a posterior lens flattening caused a myopic shift at the periphery, but a hyperopic shift of the central refraction. In the myopic eye, lens development induced refractive change toward more hyperopic over the visual fields and more at the periphery. Lens thinning and lens axial movement participate in peripheral refractive development in schoolchildren, and lens development with a deeper anterior chamber depth and a flatter lens surface in the myopic eye could generate extra hyperopia over visual fields. The myopic lens development could be due to a backward movement of the lens, driven by a backward growth of the ciliary process, which might be a causative factor of myopia development.

  13. Estimating and controlling chromatic aberration losses for two-junction, two-terminal devices in refractive concentrator systems

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, S.R. [National Renewable Energy Lab., Golden, CO (United States); O`Neill, M.J. [ENTECH, Inc., Keller, TX (United States)

    1996-05-01

    Although previous studies have measured and calculated chromatic aberration losses and proposed methods for reducing these by modifying the optics, significant work remains to be done toward understanding how to quantity the losses and how various parameters affect this loss. This paper presents an analytical definition and calculation method for chromatic aberration losses. The effects of sheet resistance of the midlayers of the cell, total irradiance, incident spectrum, cell width, and diode quality factor are studied. A method for measuring the midlayer resistance in finished sells is described.

  14. Dry Eye Disease following Refractive Surgery: A 12-Month Follow-Up of SMILE versus FS-LASIK in High Myopia

    Science.gov (United States)

    Wang, Bingjie; Chu, Renyuan; Dai, Jinhui; Qu, Xiaomei; Zhou, Hao

    2015-01-01

    Purpose. To compare dry eye disease following SMILE versus FS-LASIK. Design. Prospective, nonrandomised, observational study. Patients. 90 patients undergoing refractive surgery for myopia were included. 47 eyes underwent SMILE and 43 eyes underwent FS-LASIK. Methods. Evaluation of dry eye disease was conducted preoperatively and at 1, 3, 6, and 12 months postoperatively, using the Salisbury Eye Evaluation Questionnaire (SEEQ) and TBUT. Results. TBUT reduced following SMILE at 1 and 3 months (p dry eye disease than FS-LASIK at 6 months postoperatively but demonstrates similar degrees of dry eye disease at 12 months. PMID:26649190

  15. Prevalence of myopic shifts among patients seeking cataract surgery

    Directory of Open Access Journals (Sweden)

    Rafael Iribarren

    2013-06-01

    Full Text Available Modern cataract surgery by phacoemulsification is a widely accepted procedure with a rapid recovery time. The prescription of specific intraocular lens, implanted during surgery, makes it possible to anticipate whether the patient will need reading glasses after the procedure. The present study analyses a sample of cataract surgery patients to show the frequency of myopic shifts related to nuclear opacity, which can result in clear near vision before surgery. A non-selected sample of consecutive patients who underwent elective cataract surgery in a private clinic was studied retrospectively. The myopic shift in refraction was assessed by comparing the old prescription with the spectacle correction at the time of interviewing.The mean age of the 229 subjects studied was 71.5 ± 10.4 years (109, 47.6%, males. A myopic shift in refraction, defined as at least - 0.5 diopters, was present in 37.1% of subjects (95% CI: 30.8%-43.4%. The mean change in refraction in these subjects was -2.52 ± 1.52 diopters. The percentage of subjects who had developed a myopic shift was significantly greater in those who presented greater nuclear opalescence. There were also differences in the mean myopic shift by refractive group, with the emmetropes having the greatest myopic shift. In this study of patients seeking cataract surgery in a clinical setting, more than one third had myopic shifts in refraction. This must be taken into account in order that patients maintain the benefit of clear near vision after surgery.

  16. Population spherical aberration: associations with ametropia, age, corneal curvature, and image quality

    Directory of Open Access Journals (Sweden)

    Kingston AC

    2013-05-01

    Full Text Available Amanda C Kingston,1,2 Ian G Cox11Bausch + Lomb, Rochester, NY, USA; 2Department of Biomedical Engineering, University of Rochester, Rochester, NY, USAPurpose: The aim of this analysis was to determine the total ocular wavefront aberration values of a large phakic population of physiologically normal, ametropic eyes, gathered under the same clinical protocol using the same diagnostic wavefront sensor.Materials and methods: Studies were conducted at multiple sites in Asia, North America, Europe, and Australia. A Bausch + Lomb Zywave II Wavefront Aberrometer (Rochester, NY, USA was used to measure the lower and higher order aberrations of each eye. Data analysis was conducted using linear regression analysis to determine the relationship between total spherical aberration, ametropia, age, corneal curvature, and image quality.Results: Linear regression analysis showed no correlation (r = 0.0207, P = 0.4874 between degree of ametropia and the amount of spherical aberration. There was also no correlation when the population was stratified into myopic and hyperopic refractive groups (rm = 0.0529, Pm = 0.0804 and rh = 0.1572, Ph = 0.2754. There was a statistically significant and weak positive correlation (r = 0.1962, P < 0.001 between age and the amount of spherical aberration measured in the eye; spherical aberration became more positive with increasing age. Also, there was a statistically significant and moderately positive correlation (r = 0.3611, P < 0.001 with steepness of corneal curvature; spherical aberration became more positive with increasing power of the anterior corneal surface. Assessment of image quality using optical design software (Zemax™, Bellevue, WA, USA showed that there was an overall benefit in correcting the average spherical aberration of this population.Conclusion: Analysis of this dataset provides insights into the inherent spherical aberration of a typical phakic, pre-presbyopic, population and provides the ability to

  17. Depth-of-Focus and its Association with the Spherical Aberration Sign. A Ray-Tracing Analysis

    Directory of Open Access Journals (Sweden)

    Ravi C. Bakaraju

    2010-01-01

    Conclusions: As regards presbyopic-correction strategies that use deliberately induced aberrations to increase the depth of focus, the current study suggests that both positive and negative SA have equal potential. However, practical considerations will probably limit the useful DoF achievable through the utilization of SCE in presbyopes. for reference to a contemporary record detailing refractive history.

  18. Cataract Surgery

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  19. DISCRIMINATING BETWEEN CLOUDY, HAZY, AND CLEAR SKY EXOPLANETS USING REFRACTION

    Energy Technology Data Exchange (ETDEWEB)

    Misra, Amit K.; Meadows, Victoria S. [Astronomy Department, University of Washington, Seattle, WA 98195 (United States)

    2014-11-01

    We propose a method to distinguish between cloudy, hazy, and clear sky (free of clouds and hazes) exoplanet atmospheres that could be applicable to upcoming large aperture space- and ground-based telescopes such as the James Webb Space Telescope (JWST) and the European Extremely Large Telescope (E-ELT). These facilities will be powerful tools for characterizing transiting exoplanets, but only after a considerable amount of telescope time is devoted to a single planet. A technique that could provide a relatively rapid means of identifying haze-free targets (which may be more valuable targets for characterization) could potentially increase the science return for these telescopes. Our proposed method utilizes broadband observations of refracted light in the out-of-transit spectrum. Light refracted through an exoplanet atmosphere can lead to an increase of flux prior to ingress and subsequent to egress. Because this light is transmitted at pressures greater than those for typical cloud and haze layers, the detection of refracted light could indicate a cloud- or haze-free atmosphere. A detection of refracted light could be accomplished in <10 hr for Jovian exoplanets with JWST and <5 hr for super-Earths/mini-Neptunes with E-ELT. We find that this technique is most effective for planets with equilibrium temperatures between 200 and 500 K, which may include potentially habitable planets. A detection of refracted light for a potentially habitable planet would strongly suggest the planet was free of a global cloud or haze layer, and therefore a promising candidate for follow-up observations.

  20. DISCRIMINATING BETWEEN CLOUDY, HAZY, AND CLEAR SKY EXOPLANETS USING REFRACTION

    International Nuclear Information System (INIS)

    Misra, Amit K.; Meadows, Victoria S.

    2014-01-01

    We propose a method to distinguish between cloudy, hazy, and clear sky (free of clouds and hazes) exoplanet atmospheres that could be applicable to upcoming large aperture space- and ground-based telescopes such as the James Webb Space Telescope (JWST) and the European Extremely Large Telescope (E-ELT). These facilities will be powerful tools for characterizing transiting exoplanets, but only after a considerable amount of telescope time is devoted to a single planet. A technique that could provide a relatively rapid means of identifying haze-free targets (which may be more valuable targets for characterization) could potentially increase the science return for these telescopes. Our proposed method utilizes broadband observations of refracted light in the out-of-transit spectrum. Light refracted through an exoplanet atmosphere can lead to an increase of flux prior to ingress and subsequent to egress. Because this light is transmitted at pressures greater than those for typical cloud and haze layers, the detection of refracted light could indicate a cloud- or haze-free atmosphere. A detection of refracted light could be accomplished in <10 hr for Jovian exoplanets with JWST and <5 hr for super-Earths/mini-Neptunes with E-ELT. We find that this technique is most effective for planets with equilibrium temperatures between 200 and 500 K, which may include potentially habitable planets. A detection of refracted light for a potentially habitable planet would strongly suggest the planet was free of a global cloud or haze layer, and therefore a promising candidate for follow-up observations

  1. Patient participation in free cataract surgery: a cross-sectional study of the low-income elderly in urban China.

    Science.gov (United States)

    Lin, Haotian; Lin, Duoru; Long, Erping; Jiang, Haofeng; Qu, Bo; Tang, Jinzhu; Lin, Yingfen; Chen, Jingjing; Wu, Xiaohang; Lin, Zhuoling; Li, Xiaoyan; Liu, Zhenzhen; Zhang, Bo; Chen, Hui; Tan, Xuhua; Luo, Lixia; Liu, Yizhi; Chen, Weirong

    2016-04-15

    To explore the characteristics of the low-income elderly who underwent free cataract surgery and to determine the degree of patient satisfaction with the free cataract surgery programme in urban China. A free cataract surgery management workflow was designed as a poverty relief project in Guangzhou. In this study, participants who underwent free cataract surgery between January and August 2014 received a telephone interview based on a structured questionnaire. Data were collected on patient demographics, resources, health conditions, reasons for undergoing the free surgery and overall evaluation of the free cataract surgery programme. Among the 833 participants, the mean surgical age was 76.85±7.46 years (95% CI 76.34 to 77.36), and the male to female ratio was 385:448. The majority (94.31%, 746/791) of patients resided in the main urban districts. Patients underwent surgery 61.08±60.15 months (95% CI 56.17 to 66.00) after becoming aware of the cataract, although 66.83% of them reported that their daily lives were influenced by cataracts. Only 21.5% of the respondents underwent physical examinations that included regular eye screening, and only 6.30% were highly educated patients. Financial problems were the primary reason cited by patients for participating in the free surgery programme. Those patients with a monthly family income of 1000-2999¥ (US$161-482) per capita constituted the largest patient population. The free clinics in the parks and the free cataract surgery were highly rated (9.46 and 9.11 of 10 points) by the beneficiaries. The telephone survey revealed a high level of patient satisfaction regarding the free cataract surgery programme. Most of the patients who participated in the programme resided in major urban districts and had poor health awareness and a low level of education. The information provided by this study is crucial for improving and expanding the management of free cataract surgery programmes. NCT02633865; Post

  2. Generalized beam quality factor of aberrated truncated Gaussian laser beams

    CSIR Research Space (South Africa)

    Mafusire, C

    2011-07-01

    Full Text Available with a quadratic refractive index profile, a change in the beam quality factor can be used to infer the pre- sence of aberrations and thereby study the media of interest. For these reasons, among others, research into the beam qual- ity factor... very much like a normal lens (without the rotational symmetry associated with defocus) since the beam quality factor is calculated in the principal axes. With y-astigmatism, the lenslike behavior does not take place in the principal axes where...

  3. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    focused beam yields findings about the optic used. The collected data give interesting information about the lenses and their aberrations. Comparison of simulated and measured data shows good agreement. Following this, the fabrication process of diamond lenses is described. Diamond with its extraordinary properties is well-suited as lens material for refractive lenses. Finally, a concluding overview of the present and future work of nanofocusing lenses is given. (orig.)

  4. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    focused beam yields findings about the optic used. The collected data give interesting information about the lenses and their aberrations. Comparison of simulated and measured data shows good agreement. Following this, the fabrication process of diamond lenses is described. Diamond with its extraordinary properties is well-suited as lens material for refractive lenses. Finally, a concluding overview of the present and future work of nanofocusing lenses is given. (orig.)

  5. Effect of Cycloplegia on Corneal Biometrics and Refractive State.

    Science.gov (United States)

    Bagheri, Abbas; Feizi, Mohadeseh; Shafii, Aliakbar; Faramarzi, Amir; Tavakoli, Mehdi; Yazdani, Shahin

    2018-01-01

    To determine changes in refractive state and corneal parameters after cycloplegia with cyclopentolate hydrochloride 1% using a dual Scheimpflug imaging system. In this prospective cross-sectional study patients aged 10 to 40 years who were referred for optometric evaluation enrolled and underwent autorefraction and corneal imaging with the Galilei dual Scheimpflug system before and 30 minutes after twice instillation of medication. Changes in refraction and astigmatism were investigated. Corneal biometrics including anterior and posterior corneal curvatures, total corneal power and corneal pachymetry were compared before and after cycloplegia. Two hundred and twelve eyes of 106 subjects with mean age of 28 ± 5 years including 201 myopic and 11 hyperopic eyes were evaluated. Mean spherical equivalent refractive error before cycloplegia was -3.4 ± 2.6 D. A mean hyperopic shift of 0.4 ± 0.5 D occurred after cycloplegia ( P biometrics should be considered before cataract and refractive surgeries.

  6. Multivariate correlation analysis of eye cyclotorsion degree in corneal refractive surgery

    Directory of Open Access Journals (Sweden)

    Xiao-Guang Niu

    2015-06-01

    Full Text Available AIM: To explore the correlation between eye cyclotorsion degrees and patient's age, gender, diopter and other factors in corneal refractive surgery. METHODS: A total of 762 wavefront-guided LASIK patients with 1524 eyes were retrospectively analyzed from January 2010 to December 2013 in our hospital. Iris recognition was accomplished successfully and eye cyclotorsion degrees were recorded intraoperatively for all the patients. The correlations between eye cyclotorsion degrees and patient's age, gender, different eye, diopter and the dominant eye or not were statistically analyzed. In which correlation analysis was used to analyze the relationship between eye cyclotorsion degrees and age and diopter, while the correlations with gender, different eye and the dominant eye or not were analyzed using t-test.RESULTS: The eye cyclotorsion degrees of patients were 0 to 9.7 degrees with an average of 3.08±2.22 degrees. Amongst the average cyclotorsion of 444 men with 888 eyes were 3.05±2.26 degrees, 318 women with 636 eyes were 3.12±2.15 degrees and there were no significant differences(t=1.905, P=0.168. The average age of all the patients was 22.6±5.4y. No significant correlation was found between cyclotorsion degrees and age(r=-0.012, P=0.748. The mean spherical equivalent was -4.76±1.77 degrees, and there was no significant correlation between the eye cyclotorsion degrees and spherical equivalent(r=0.017, P=0.633. The mean cylinder was -0.60±0.64 degrees of no significant correlation with eye cyclotorsion degrees(r=-0.004, P=0.910. The cyclotorsion of dominant eyes of all the patients was 3.0±2.17 degrees, and the non-dominant eyes were 3.11±2.12 degrees. No significant differences were found(t=-0.521,P=0.603. CONCLUSION: The eye cyclotorsion degrees occurred in LASIK surgery had no correlation with age, gender, different eye, diopter and the dominant eye or not.

  7. Laser Eye Surgery: MedlinePlus Health Topic

    Science.gov (United States)

    ... corneal surgery - discharge (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Laser Eye Surgery ... surgery - what to ask your doctor Related Health Topics Refractive Errors National Institutes of Health The primary ...

  8. Do Peripheral Refraction and Aberration Profiles Vary with the Type of Myopia? - An Illustration Using a Ray-Tracing Approach

    Directory of Open Access Journals (Sweden)

    Ravi C. Bakaraju

    2009-01-01

    Conclusion: This study has indicated that myopic eyes with primarily an axial component may have a greater risk of progression than their refractive counterparts albeit with the same degree of refractive error. This prediction emerges from the presented theoretical ray tracing model and, therefore, requires clinical confirmation.

  9. LASIK - Laser Eye Surgery

    Science.gov (United States)

    ... Refractive Surgery Procedures What Is Photorefractive Keratectomy (PRK)? LASIK — Laser Eye Surgery Leer en Español: LASIK—Cirugía ocular con láser ... loss of close-up focusing power. How the LASIK procedure works LASIK is performed while the patient ...

  10. Integrated dual-tomography for refractive index analysis of free-floating single living cell with isotropic superresolution.

    Science.gov (United States)

    B, Vinoth; Lai, Xin-Ji; Lin, Yu-Chih; Tu, Han-Yen; Cheng, Chau-Jern

    2018-04-13

    Digital holographic microtomography is a promising technique for three-dimensional (3D) measurement of the refractive index (RI) profiles of biological specimens. Measurement of the RI distribution of a free-floating single living cell with an isotropic superresolution had not previously been accomplished. To the best of our knowledge, this is the first study focusing on the development of an integrated dual-tomographic (IDT) imaging system for RI measurement of an unlabelled free-floating single living cell with an isotropic superresolution by combining the spatial frequencies of full-angle specimen rotation with those of beam rotation. A novel 'UFO' (unidentified flying object) like shaped coherent transfer function is obtained. The IDT imaging system does not require any complex image-processing algorithm for 3D reconstruction. The working principle was successfully demonstrated and a 3D RI profile of a single living cell, Candida rugosa, was obtained with an isotropic superresolution. This technology is expected to set a benchmark for free-floating single live sample measurements without labeling or any special sample preparations for the experiments.

  11. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  12. Fabrication of Radiation Shielding Glasses Based on Lead-free High Refractive Index Glasses Prepared from Local Sand

    International Nuclear Information System (INIS)

    Dararutana, Pisutti; Dutchaneepet, Jirapan; Sirikulrat, Narin

    2007-08-01

    Full text: Lead glasses that show high refractive index are the best know and most popular for radiation shielding. Due to harmful effects of lead and considering the health as well as the environmental issues, lead-free glasses were developed. In this work, content of Chumphon sand was fixed at 40 % (by weight) as a main composition but concentrations of BaCO3 were varied from 6 to 30 % (by weight). It was found that the absorption coefficient of the glass samples containing 30 % BaCO3 was 0.233 cm-1 for Ba-133. The density was also measured. It can be concluded that the prepared lead free glasses offered adequate shielding to gamma radiation in comparison with the lead ones. These glasses were one of the environmental friendly materials

  13. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  14. Comparing the relative peripheral refraction effect of single vision and multifocal contact lenses measured using an autorefractor and an aberrometer: A pilot study

    Directory of Open Access Journals (Sweden)

    Ravi C. Bakaraju

    2015-07-01

    Conclusion: For most test conditions, distinct differences were observed between the RPR measures obtained with the two modified instruments. The differences varied with CL design and centration. Although the pilot study supports the interchangeable use of the two instruments for on- and off-axis refraction in unaided eyes or eyes corrected with low/no spherical aberration; we advocate the use of the COAS-HD over the SN for special purposes like refracting through multifocal CLs.

  15. Control-matched comparison of refractive and visual outcomes between small incision lenticule extraction and femtosecond laser-assisted LASIK

    Directory of Open Access Journals (Sweden)

    Kataoka T

    2018-05-01

    Full Text Available Takahiro Kataoka,1 Tomoya Nishida,1 Azusa Murata,1 Mayuka Ito,1 Naoki Isogai,1 Rie Horai,1 Takashi Kojima,1,2 Yoko Yoshida,1 Tomoaki Nakamura1 1Nagoya Eye Clinic, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan Purpose: This retrospective case-matched study aimed to compare visual and refractive outcomes between small incision lenticule extraction (SMILE and LASIK. Patients and methods: Patients who underwent SMILE (34 eyes of 23 patients or LASIK (34 eyes of 24 patients were enrolled and matched according to preoperative manifest refractive spherical equivalents. The mean preoperative manifest refractive spherical equivalent was −4.69±0.6 and −4.67±0.64 D in the SMILE and LASIK groups, respectively. The safety, efficacy, and predictability were compared 3 months after surgery. Changes in corneal refractive power from the center to peripheral points and their maintenance ratios were analyzed and compared between the two groups. Results: In the SMILE and LASIK groups, 82.4% and 85.3% of patients, respectively, achieved 20/13 or better uncorrected distance visual acuity (p=1.00. There were no eyes that lost two or more lines of corrected distance visual acuity in either group. The maintenance ratios of corneal refractive power changes at the peripheral points in the SMILE group were significantly higher than those in the LASIK group (p<0.05. Conclusion: Both groups achieved similar high efficacy and safety. SMILE surgery resulted in higher refractive power correction in the peripheral cornea than LASIK surgery. Keywords: small incision lenticule extraction, LASIK, corneal refractive power, refractive power correction efficiency, corneal topography

  16. Chromosomal aberration

    International Nuclear Information System (INIS)

    Ishii, Yutaka

    1988-01-01

    Chromosomal aberrations are classified into two types, chromosome-type and chromatid-type. Chromosom-type aberrations include terminal deletion, dicentric, ring and interstitial deletion, and chromatid-type aberrations include achromatic lesion, chromatid deletion, isochromatid deletion and chromatid exchange. Clastogens which induce chromosomal aberration are divided into ''S-dependent'' agents and ''S-independent''. It might mean whether they can induce double strand breaks independent of the S phase or not. Double strand breaks may be the ultimate lesions to induce chromosomal aberrations. Caffeine added even in the G 2 phase appeared to modify the frequency of chromatid aberrations induced by X-rays and mitomycin C. Those might suggest that the G 2 phase involves in the chromatid aberration formation. The double strand breaks might be repaired by ''G 2 repair system'', the error of which might yield breakage types of chromatid aberrations and the by-pass of which might yield chromatid exchanges. Chromosome-type aberrations might be formed in the G 1 phase. (author)

  17. Carrier and aberrations removal in interferometric fringe projection profilometry

    Science.gov (United States)

    Blain, P.; Michel, F.; Renotte, Y.; Habraken, S.

    2012-04-01

    A profilometer which takes advantage of polarization states splitting technique and monochromatic light projection method as a way to overcome ambient lighting for in-situ measurement is under development [1, 2]. Because of the Savart plate which refracts two out of axis beams, the device suffers from aberrations (mostly coma and astigmatism). These aberrations affect the quality of the sinusoidal fringe pattern. In fringe projection profilometry, the unwrapped phase distribution map contains the sum of the object's shape-related phase and carrier-fringe-related phase. In order to extract the 3D shape of the object, the carrier phase has to be removed [3, 4]. An easy way to remove both the fringe carrier and the aberrations of the optical system is to measure the phases of the test object and to measure the phase of a reference plane with the same set up and to subtract both phase maps. This time consuming technique is suitable for laboratory but not for industry. We propose a method to numerically remove both the fringe carrier and the aberrations. A first reference phase of a calibration plane is evaluated knowing the position of the different elements in the set up and the orientation of the fringes. Then a fitting of the phase map by Zernike polynomials is computed [5]. As the triangulation parameters are known during the calibration, the computation of Zernike coefficients has only to be made once. The wavefront error can be adjusted by a scale factor which depends on the position of the test object.

  18. THz-induced ultrafast modulation of NIR refractive index of silicon

    DEFF Research Database (Denmark)

    Tarekegne, Abebe Tilahun; Hirori, Hideki; Iwaszczuk, Krzysztof

    2016-01-01

    We measure THz-induced change in refractive index of ∼5×10−3 in high resistivity silicon at 800 nm which indicates generation of high density of free carriers. The change in refractive index increases by more than 30 times with high initial carrier density set by optical excitation compared to op...

  19. Simultaneous refractive index and thickness measurement with the transmission interferometric adsorption sensor

    Energy Technology Data Exchange (ETDEWEB)

    Sannomiya, Takumi; Voeroes, Janos [Laboratory of Biosensors and Bioelectronics, Department of Information Technology and Electrical Engineering, ETH Zurich, 8092, Zurich (Switzerland); Balmer, Tobias E [Materials Research Center, ETH Zurich, 8093, Zurich (Switzerland); Heuberger, Manfred, E-mail: sannomiya@biomed.ee.ethz.c, E-mail: tobias.balmer@mat.ethz.c, E-mail: manfred.heuberger@empa.c, E-mail: janos.voros@biomed.ee.ethz.c [Laboratory for Surface Science and Technology, Department of Materials, ETH Zurich, 8093, Zurich (Switzerland)

    2010-10-13

    Refractive index and thickness of the adlayer are determined simultaneously using the transmission interferometric adsorption sensor (TInAS). Optical biosensors, where both refractive index and thickness of a homogeneous adlayer (thus the adsorbed mass) are determined simultaneously, so-called model-free biosensors, are important tools to investigate the adsorbed mass of biomolecules with unknown conformation. Our proposed calculation method enables model-free biosensing from a single spectrum acquired by a simple TInAS setup, namely using information of peak/dip positions as well as peak/dip intensities. The feasibility of this method was experimentally tested by adsorbing polyelectrolyte multilayer as well as biomolecules. To validate the new method also for the more intricate heterogeneous adlayer, the apparent refractive index and thickness were assessed theoretically by simulating a selection of different adsorbate configurations with the multiple multipole program (MMP). We found that a lateral inhomogeneity of the adsorbate (e.g. islands or adsorbed colloids) results in correct thickness and in reduced refractive index averaged in proportion to their density while vertically inhomogeneous density caused more complex responses. However, the apparent mass was always correct. Measurement errors can lead to significant errors in the apparent refractive index, particularly when the adlayer is very thin (<5 nm). This model-free TInAS technique would be useful not only for the measurement of adsorbed mass but also for the conformational analysis of the adsorbed molecules.

  20. Surface Modifier-Free Organic-Inorganic Hybridization To Produce Optically Transparent and Highly Refractive Bulk Materials Composed of Epoxy Resins and ZrO2 Nanoparticles.

    Science.gov (United States)

    Enomoto, Kazushi; Kikuchi, Moriya; Narumi, Atsushi; Kawaguchi, Seigou

    2018-04-25

    Surface modifier-free hybridization of ZrO 2 nanoparticles (NPs) with epoxy-based polymers is demonstrated for the first time to afford highly transparent and refractive bulk materials. This is achieved by a unique and versatile hybridization via the one-pot direct phase transfer of ZrO 2 NPs from water to epoxy monomers without any aggregation followed by curing with anhydride. Three types of representative epoxy monomers, bisphenol A diglycidyl ether (BADGE), 3,4-epoxycyclohexylmethyl-3',4'-epoxycyclohexane carboxylate (CEL), and 1,3,5-tris(3-(oxiran-2-yl)propyl)-1,3,5-triazinane-2,4,6-trione (TEPIC), are used to produce transparent viscous dispersions. The resulting ZrO 2 NPs are thoroughly characterized using dynamic light scattering (DLS), transmission electron microscopy (TEM), Fourier transform infrared (FT-IR), and solid-state 13 C CP/MAS NMR measurements. The results from DLS and TEM analyses indicate nanodispersion of ZrO 2 into epoxy monomers as a continuous medium. A surface modification mechanism and the binding fashion during phase transfer are proposed based on the FT-IR and solid-state 13 C CP/MAS NMR measurements. Epoxy-based hybrid materials with high transparency and refractive index are successfully fabricated by heat curing or polymerizing a mixture of monomers containing epoxy-functionalized ZrO 2 NPs and methylhexahydrophthalic anhydride in the presence of a phosphoric catalyst. The TEM and small-angle X-ray scattering measurements of the hybrids show a nanodispersion of ZrO 2 in the epoxy networks. The refractive index at 594 nm ( n 594 ) increases up to 1.765 for BADGE-based hybrids, 1.667 for CEL-based hybrids, and 1.693 for TEPIC-based hybrids. Their refractive indices and Abbe's numbers are quantitatively described by the Lorentz-Lorenz effective medium expansion theory. Their transmissivity is also reasonably explained using Fresnel refraction, Rayleigh scattering, and the Lambert-Beer theories. This surface modifier-free hybridization

  1. Contralateral comparison of wavefront-guided LASIK surgery with iris recognition versus without iris recognition using the MEL80 Excimer laser system.

    Science.gov (United States)

    Wu, Fang; Yang, Yabo; Dougherty, Paul J

    2009-05-01

    To compare outcomes in wavefront-guided LASIK performed with iris recognition software versus without iris recognition software in different eyes of the same patient. A randomised, prospective study of 104 myopic eyes of 52 patients undergoing LASIK surgery with the MEL80 excimer laser system was performed. Iris recognition software was used in one eye of each patient (study group) and not used in the other eye (control group). Higher order aberrations (HOAs), contrast sensitivity, uncorrected vision (UCV), visual acuity (VA) and corneal topography were measured and recorded pre-operatively and at one month and three months post-operatively for each eye. The mean post-operative sphere and cylinder between groups was similar, however the post-operative angles of error (AE) by refraction were significantly smaller in the study group compared to the control group both in arithmetic and absolute means (p = 0.03, p = 0.01). The mean logMAR UCV was significantly better in the study group than in the control group at one month (p = 0.01). The mean logMAR VA was significantly better in the study group than in control group at both one and three months (p = 0.01, p = 0.03). In addition, mean trefoil, total third-order aberration, total fourth-order aberration and the total scotopic root-mean-square (RMS) HOAs were significantly less in the study group than those in the control group at the third (p = 0.01, p = 0.05, p = 0.04, p = 0.02). By three months, the contrast sensitivity had recovered in both groups but the study group performed better at 2.6, 4.2 and 6.6 cpd (cycles per degree) than the control group (p = 0.01, p iris recognition results in better VA, lower mean higher-order aberrations, lower refractive post-operative angles of error and better contrast sensitivity at three months post-operatively than LASIK performed without iris recognition.

  2. Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses.

    Science.gov (United States)

    Yu, Qing; Wu, Jiang-Xiu; Zhang, He-Ning; Ye, Sheng; Dong, Shi-Qi; Zhang, Chen-Hao

    2013-01-01

    To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction. The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use. Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows: root mean square (RMS) (pre)=(1.438±0.328)µm, RMS (30 minutes)=(1.076±0.355)µm, RMS (1 day)=(1.362±0.402)µm, RMS (3 days)=(1.373±0.398)µm, RMS (7 days)=(1.387±0.415)µm, and RMS (14 days)=(1.430±0.423)µm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2(nd)- and 3(rd)-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4(th)-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were not significantly different from the values prior to use. The use RGP contact lenses greatly reduced total aberration of the anterior surface of

  3. Short-term stability in refractive status despite large fluctuations in glucose levels in diabetes mellitus type 1 and 2.

    Directory of Open Access Journals (Sweden)

    Byki Huntjens

    Full Text Available PURPOSE: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. METHODS: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45, central corneal thickness (CCT, anterior chamber depth (ACD, crystalline lens thickness (LT, axial length (AL and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. RESULTS: Blood glucose concentration at different times was found to vary significantly within (p0.05. Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. CONCLUSION: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients.

  4. Clinical Outcomes of SMILE With a Triple Centration Technique and Corneal Wavefront-Guided Transepithelial PRK in High Astigmatism.

    Science.gov (United States)

    Jun, Ikhyun; Kang, David Sung Yong; Reinstein, Dan Z; Arba-Mosquera, Samuel; Archer, Timothy J; Seo, Kyoung Yul; Kim, Tae-Im

    2018-03-01

    To comparatively investigate the clinical outcomes, vector parameters, and corneal aberrations of small incision lenticule extraction (SMILE) with a triple centration technique and corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) for the correction of high astigmatism. This retrospective, comparative case series study included 89 eyes (89 patients) that received treatment for myopia with high astigmatism (≥ 2.50 diopters) using SMILE with a triple centration technique (SMILE group; 45 eyes) and corneal wavefront-guided transepithelial PRK (transepithelial PRK group; 44 eyes). Visual acuity measurement, manifest refraction, slit-lamp examination, autokeratometry, corneal topography, and evaluation of corneal wavefront aberration were performed preoperatively and at 1, 3, and 6 months after surgery. The safety, efficacy, vector parameters, and corneal aberrations at 6 months after surgery were compared between the two groups. At 6 months after surgery, the transepithelial PRK and SMILE groups exhibited comparable mean uncorrected distance visual acuities (-0.06 ± 0.07 and -0.05 ± 0.07 logMAR, respectively), safety, efficacy, and predictability of refractive and visual outcomes. There was a slight but statistically significant difference in the correction index between the transepithelial PRK and SMILE groups (0.96 ± 0.11 and 0.91 ± 0.10, respectively). Whereas the transepithelial PRK group exhibited increased corneal spherical aberration and significantly reduced corneal coma and trefoil, no changes in aberrometric values were noted in the SMILE group. Both SMILE with a triple centration technique and corneal wavefront-guided transepithelial PRK are effective and provide predictable outcomes for the correction of high myopic astigmatism, although slight undercorrection was observed in the SMILE group. The triple centration technique was helpful in astigmatism correction by SMILE. [J Refract Surg. 2018;34(3):156-163.]. Copyright 2018

  5. A Right-sided Aortic Arch with Kommerell's Diverticulum of the Aberrant Left Subclavian Artery Presenting with Syncope

    Directory of Open Access Journals (Sweden)

    Ming-Hsun Yang

    2009-05-01

    Full Text Available A right-sided aortic arch with an aneurysm of the aberrant subclavian artery is a rare disease. We report a case of Kommerell's diverticulum of an aberrant left subclavian artery in a patient with a right-sided aortic arch. Fewer than 50 cases have been reported in the literature. A number of operative strategies are described. Right thoracotomy provides good exposure and avoids the morbidity associated with bilateral thoracotomy or sternotomy and thoracotomy. In our patient with symptoms of dysphagia, syncope, and left subclavian steal syndrome, a left thoracotomy was used. The repair was accomplished by division of a left ligamentum arteriosum, obliteration of the Kommerell's aneurysm, and an aorto-subclavian bypass. Postoperative complications included left vocal cord palsy and Horner's syndrome. Hoarseness and left ptosis recovered spontaneously 3 months after surgery, and the patient remained symptom-free at the 1-year follow-up. We believe a left thoracotomy for direct repair of Kommerell's diverticulum is a simple and safe method without the increased morbidity found in other procedures.

  6. Mudanças na refração após cirurgia de correção de esotropia Refractive changes following surgery for correction of esotropia

    Directory of Open Access Journals (Sweden)

    Marcelo F. Gaal Vadas

    2001-08-01

    Full Text Available Objetivo: Estudar o comportamento da refração e da curvatura corneana em pacientes com esotropia essencial submetidos à cirurgia monocular para correção do estrabismo. Métodos: Estudo prospectivo em que 42 olhos de 21 pacientes com esotropia essencial de ângulo moderado, sem quaisquer outros estrabismos associados, foram selecionados e submetidos ao exame oftalmológico completo e à cirurgia monocular. O olho contralateral serviu como grupo controle. Foram feitas avaliações de pré-operatório, pós-operatório de 1 mês e pós-operatório de 6 meses. O astigmatismo pré-operatório foi confrontado com os astigmatismos pós-operatórios por análise vetorial e cálculo do valor polar. Resultados: Obtivemos, nos olhos operados, redução significante (pPurpose: To evaluate changes in refraction and corneal curvature following surgery for correction of acquired esotropia. Methods: 42 eyes of 21 patients with acquired moderate angle esotropia without any other form of strabismus were prospectively enrolled and submitted to a complete ophthalmological examination followed by recess/resect procedure in a single eye. Data from the fellow eye were selected as control. Ophthalmological assessment was carried out preoperatively, 1 month after surgery and 6 months after surgery, where astigmatism was compared using vector analysis and the polar value concept. Results: The eyes submitted to surgery revealed a significant (p<0.05 decrease in spherical equivalent, from 3.28 ± 1.98 diopters to 3.05 ± 1.95 diopters. Refraction data disclosed a significant increase in the 90° component of net astigmatism, from 0.458 ± 0.594 diopters to 1.002 ± 0.718 diopters, which was also observed in keratometric readings:1.083 ± 0.560 diopters to 1.690 ± 0.591 diopters. Surgically induced astigmatism, assessed using refraction data was 0.63 ± 0.27 diopters at an average axis of 92.30 ± 14.91 degrees, and 0.71 ± 0.27 diopters at an average axis of 94.45

  7. Disease-free survival after complete mesocolic excision compared with conventional colon cancer surgery

    DEFF Research Database (Denmark)

    Bertelsen, Claus Anders; Neuenschwander, Anders Ulrich; Jansen, Jens Erik

    2015-01-01

    BACKGROUND: Application of the principles of total mesorectal excision to colon cancer by undertaking complete mesocolic excision (CME) has been proposed to improve oncological outcomes. We aimed to investigate whether implementation of CME improved disease-free survival compared with conventional...... consisted of patients who underwent CME surgery in a centre validated to perform such surgery; the control group consisted of patients undergoing conventional colon resection in three other hospitals. Data were collected from the Danish Colorectal Cancer Group (DCCG) database and medical charts. Patients...... updated by the National Central Office of Civil Registration. FINDINGS: The CME group consisted of 364 patients and the non-CME group consisted of 1031 patients. For all patients, 4-year disease-free survival was 85.8% (95% CI 81.4-90.1) after CME and 75.9% (72.2-79.7) after non-CME surgery (log-rank p=0...

  8. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  9. The quality of systematic reviews about interventions for refractive error can be improved: a review of systematic reviews.

    Science.gov (United States)

    Mayo-Wilson, Evan; Ng, Sueko Matsumura; Chuck, Roy S; Li, Tianjing

    2017-09-05

    Systematic reviews should inform American Academy of Ophthalmology (AAO) Preferred Practice Pattern® (PPP) guidelines. The quality of systematic reviews related to the forthcoming Preferred Practice Pattern® guideline (PPP) Refractive Errors & Refractive Surgery is unknown. We sought to identify reliable systematic reviews to assist the AAO Refractive Errors & Refractive Surgery PPP. Systematic reviews were eligible if they evaluated the effectiveness or safety of interventions included in the 2012 PPP Refractive Errors & Refractive Surgery. To identify potentially eligible systematic reviews, we searched the Cochrane Eyes and Vision United States Satellite database of systematic reviews. Two authors identified eligible reviews and abstracted information about the characteristics and quality of the reviews independently using the Systematic Review Data Repository. We classified systematic reviews as "reliable" when they (1) defined criteria for the selection of studies, (2) conducted comprehensive literature searches for eligible studies, (3) assessed the methodological quality (risk of bias) of the included studies, (4) used appropriate methods for meta-analyses (which we assessed only when meta-analyses were reported), (5) presented conclusions that were supported by the evidence provided in the review. We identified 124 systematic reviews related to refractive error; 39 met our eligibility criteria, of which we classified 11 to be reliable. Systematic reviews classified as unreliable did not define the criteria for selecting studies (5; 13%), did not assess methodological rigor (10; 26%), did not conduct comprehensive searches (17; 44%), or used inappropriate quantitative methods (3; 8%). The 11 reliable reviews were published between 2002 and 2016. They included 0 to 23 studies (median = 9) and analyzed 0 to 4696 participants (median = 666). Seven reliable reviews (64%) assessed surgical interventions. Most systematic reviews of interventions for

  10. Reading ability with pseudophakic monovision and with refractive multifocal intraocular lenses: comparative study.

    Science.gov (United States)

    Ito, Misae; Shimizu, Kimiya

    2009-09-01

    To the compare the reading ability after bilateral cataract surgery in patients who had pseudophakic monovision achieved by monofocal intraocular lens (IOL) implantation and patients who had refractive multifocal IOL implantation. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. This study evaluated patients who had bilateral cataract surgery using the monovision method with monofocal IOL implantation to correct presbyopia (monovision group) or who had bilateral cataract surgery with refractive multifocal IOL implantation (multifocal group). In the monovision group, the dominant eye was corrected for distance vision and the nondominant eye for near vision. The maximum reading speed, critical character size, and reading acuity were measured binocularly without refractive correction using MNREAD-J acuity charts. The monovision group comprised 38 patients and the multifocal group, 22 patients. The mean maximum reading speed was 350.5 characters per minute (cpm) +/- 62.3 (SD) in the monovision group and 355.0 +/- 53.3 cpm in the multifocal group; the difference was not statistically significant. The mean critical character size was 0.24 +/- 0.12 logMAR and 0.40 +/- 0.16 logMAR, respectively (P<.05). The mean reading acuity was 0.05 +/- 0.12 logMAR and 0.19 +/- 0.11 logMAR, respectively (P<.01). The monovision group had better critical character size and reading acuity results. The monovision method group had better reading ability; however, careful patient selection is essential.

  11. Changes in monkey crystalline lens spherical aberration during simulated accommodation in a lens stretcher.

    Science.gov (United States)

    Maceo Heilman, Bianca; Manns, Fabrice; de Castro, Alberto; Durkee, Heather; Arrieta, Esdras; Marcos, Susana; Parel, Jean-Marie

    2015-02-10

    The purpose of this study was to quantify accommodation-induced changes in the spherical aberration of cynomolgus monkey lenses. Twenty-four lenses from 20 cynomolgus monkeys (Macaca fascicularis; 4.4-16.0 years of age; postmortem time 13.5 ± 13.0 hours) were mounted in a lens stretcher. Lens spherical aberration was measured in the unstretched (accommodated) and stretched (relaxed) states with a laser ray tracing system that delivered 51 equally spaced parallel rays along 1 meridian of the lens over the central 6-mm optical zone. A camera mounted below the lens was used to measure the ray height at multiple positions along the optical axis. For each entrance ray, the change in ray height with axial position was fitted with a third-order polynomial. The effective paraxial focal length and Zernike spherical aberration coefficients corresponding to a 6-mm pupil diameter were extracted from the fitted values. The unstretched lens power decreased with age from 59.3 ± 4.0 diopters (D) for young lenses to 45.7 ± 3.1 D for older lenses. The unstretched lens shifted toward less negative spherical aberration with age, from -6.3 ± 0.7 μm for young lenses to -5.0 ± 0.5 μm for older lenses. The power and spherical aberration of lenses in the stretched state were independent of age, with values of 33.5 ± 3.4 D and -2.6 ± 0.5 μm, respectively. Spherical aberration is negative in cynomolgus monkey lenses and becomes more negative with accommodation. These results are in good agreement with the predicted values using computational ray tracing in a lens model with a reconstructed gradient refractive index. The spherical aberration of the unstretched lens becomes less negative with age. Copyright 2015 The Association for Research in Vision and Ophthalmology, Inc.

  12. Changes in higher order aberrations after wavefront-guided PRK for correction of low to moderate myopia and myopic astigmatism: two-year follow-up.

    Science.gov (United States)

    Wigledowska-Promienska, D; Zawojska, I

    2007-01-01

    To assess efficacy, safety, and changes in higher order aberrations after wavefront-guided photorefractive keratectomy (PRK) in comparison with conventional PRK for low to moderate myopia with myopic astigmatism using a WASCA Workstation with the MEL 70 G-Scan excimer laser. A total of 126 myopic or myopic-astigmatic eyes of 112 patients were included in this retrospective study. Patients were divided into two groups: Group 1, the study group; and Group 2, the control group. Group 1 consisted of 78 eyes treated with wavefront-guided PRK. Group 2 consisted of 48 eyes treated with spherocylindrical conventional PRK. Two years postoperatively, in Group 1, 5% of eyes achieved an uncorrected visual acuity (UCVA) of 0.05; 69% achieved a UCVA of 0.00; 18% of eyes experienced enhanced visual acuity of -0.18 and 8% of -0.30. In Group 2, 8% of eyes achieved a UCVA of 0.1; 25% achieved a UCVA of 0.05; and 67% achieved a UCVA of 0.00 according to logMAR calculation method. Total higher-order root-mean square increased by a factor 1.18 for Group 1 and 1.6 for Group 2. There was a significant increase of coma by a factor 1.74 in Group 2 and spherical aberration by a factor 2.09 in Group 1 and 3.56 in Group 2. The data support the safety and effectiveness of the wavefront-guided PRK using a WASCA Workstation for correction of low to moderate refractive errors. This method reduced the number of higher order aberrations induced by excimer laser surgery and improved uncorrected and spectacle-corrected visual acuity when compared to conventional PRK.

  13. Lowered threshold energy for femtosecond laser induced optical breakdown in a water based eye model by aberration correction with adaptive optics.

    Science.gov (United States)

    Hansen, Anja; Géneaux, Romain; Günther, Axel; Krüger, Alexander; Ripken, Tammo

    2013-06-01

    In femtosecond laser ophthalmic surgery tissue dissection is achieved by photodisruption based on laser induced optical breakdown. In order to minimize collateral damage to the eye laser surgery systems should be optimized towards the lowest possible energy threshold for photodisruption. However, optical aberrations of the eye and the laser system distort the irradiance distribution from an ideal profile which causes a rise in breakdown threshold energy even if great care is taken to minimize the aberrations of the system during design and alignment. In this study we used a water chamber with an achromatic focusing lens and a scattering sample as eye model and determined breakdown threshold in single pulse plasma transmission loss measurements. Due to aberrations, the precise lower limit for breakdown threshold irradiance in water is still unknown. Here we show that the threshold energy can be substantially reduced when using adaptive optics to improve the irradiance distribution by spatial beam shaping. We found that for initial aberrations with a root-mean-square wave front error of only one third of the wavelength the threshold energy can still be reduced by a factor of three if the aberrations are corrected to the diffraction limit by adaptive optics. The transmitted pulse energy is reduced by 17% at twice the threshold. Furthermore, the gas bubble motions after breakdown for pulse trains at 5 kilohertz repetition rate show a more transverse direction in the corrected case compared to the more spherical distribution without correction. Our results demonstrate how both applied and transmitted pulse energy could be reduced during ophthalmic surgery when correcting for aberrations. As a consequence, the risk of retinal damage by transmitted energy and the extent of collateral damage to the focal volume could be minimized accordingly when using adaptive optics in fs-laser surgery.

  14. Povidone-Iodine Concentration and Dosing in Cataract Surgery.

    Science.gov (United States)

    Koerner, Jagger C; George, Mary J; Meyer, Dale R; Rosco, Michael G; Habib, Matthew M

    2018-05-17

    Iodine has been recognized as an effective bactericide since the 1800's, and povidone-iodine (PI) solution has been applied to the ocular surface and periocular skin since the 1980's to prevent endophthalmitis in cataract surgery. In vitro, PI solution kills bacteria very quickly at dilute concentrations (0.05-1.0%). In many instances, PI kills bacteria more quickly at these dilute concentrations than more conventional (5%-10%) concentrations. This is due to greater availability of diatomic free iodine in dilute solution, the bactericidal component of PI. The toxicity of PI, both in vitro and clinically has been shown to be related to concentration. Current American Academy of Ophthalmology (AAO) and the European Society of Cataract and Refractive Surgeons (ESCRS) recommendations regarding PI use suggest using 5% PI prior to surgery. An alternative dosing strategy uses dilute PI repetitively throughout cataract surgery (0.25% every thirty seconds). We review the povidone-iodine literature with attention to basic science and use of dilute PI. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. The anatomy of forearm free flap phalloplasty for transgender surgery.

    Science.gov (United States)

    Kim, S; Dennis, M; Holland, J; Terrell, M; Loukas, M; Schober, J

    2018-03-01

    Transgender surgeries are becoming more frequent and visual interpretation of anatomy is essential for both surgeons and patients. Since the forearm free flap phalloplasty was introduced in 1984, it has been known to provide reliable cosmetic and functional results for transitioning men compared with phalloplasty by different flaps. Surgical text descriptions were enhanced by the creation of new anatomic illustrations. The forearm free flap consists of the anterior forearm skin, subcutaneous tissue, fascia containing the radial artery as the perforator and its venae comitantes, cephalic and basilic veins, and lateral and medial antebrachial cutaneous nerves are demonstrated in relation to the surgically derived flap. Song's forearm free flap phalloplasty requires two surgical stages with a three-month interval between the stages: prelamination of a neourethra and construction of a neophallus. The neophallus created by forearm flap phalloplasty is reported to achieve acceptable aesthetical and psychological satisfaction, appropriate size and shape, and satisfying sexual intercourse. Despite increasing experiences in gender confirming surgery with modifications made by many authors, urethral complications including fistula and/or stricture formation are the leading causes of reoperation. The poor esthetic outcome of the forearm donor site and a decrease in rigidity of the neophallus are the main limitations. Illustrations of anatomy help inform surgical choice and understanding of risks and benefits by patients. The anatomy of the free forearm flap phalloplasty supports creation of a neophallus for transsexual anatomy revision. Clin. Anat. 31:145-151, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses

    Directory of Open Access Journals (Sweden)

    Shi-Qi Dong

    2013-04-01

    Full Text Available AIM: To record aberrations with a corneal topographic device on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP contact lenses. The effect of wearing RGP on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction. METHODS: The study objects were 24 eyes from 24 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry and corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses everyday for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 minutes, 1 day, 3, 7 and 14 days following use. RESULTS: Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results were as follows:root mean square (RMS (pre=(1.438±0.328μm, RMS (30 minutes=(1.076±0.355μm, RMS (1 day=(1.362±0.402μm, RMS (3 days=(1.373±0.398μm, RMS (7 days=(1.387±0.415μm, and RMS (14 days=(1.430±0.423μm. Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2nd- and 3rd-order aberrations change. Quadrafoil Z10 and spherical Z12 of the 4th-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant differences compared with the time period prior to RGP use:Z5 and Z6 decreased, and Z12 increased slightly. Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use. At 14 days after discontinued use, all aberrations were not significantly different from the values prior to use. CONCLUSION: The use RGP contact lenses greatly reduced total

  17. Visual and Refractive Outcomes in Manual versus Femtosecond Laser-Assisted Cataract Surgery: A Single-Center Retrospective Cohort Analysis of 1838 Eyes.

    Science.gov (United States)

    Berk, Thomas A; Schlenker, Matthew B; Campos-Möller, Xavier; Pereira, Austin M; Ahmed, Iqbal Ike K

    2018-03-06

    Femtosecond laser-assisted cataract surgery (FLACS) has emerged as an alternative to manual cataract surgery (MCS) for corneal incision and capsulorhexis creation, as well as nuclear fragmentation. This study compares postoperative refractive and visual outcomes in eyes receiving MCS or FLACS. Single-center, comparative, retrospective cohort analysis. Consecutive eyes receiving FLACS and MCS from July 1, 2012, to July 31, 2015, at a single tertiary care center. Demographic data, ocular history, preoperative measurements and biometry, and postoperative surgical results were retrospectively obtained and statistically analyzed using a generalized linear mixed model adjusting for differences in baseline characteristics and within-patient correlation. A 2-tailed P value <0.05 was considered statistically significant throughout the study. Percentage of eyes achieving absolute error (AE) ≤0.5 diopters (D). Secondary outcomes included percentage of eyes with AE ≤0.25 D and ≤1.0 D, and percentage of distance-targeted eyes achieving uncorrected distance visual acuity (UDVA) of 20/20 or better, 20/25 or better, and 20/30 or better. A total of 883 eyes received MCS and 955 received FLACS among 1089 patients. Some 82.6% of FLACS eyes and 78.8% of MCS eyes had ≤0.5 D of AE at 3 weeks, representing an adjusted odds ratio (OR) of 1.28 (95% confidence interval [CI], 0.98-1.66) of FLACS relative to MCS being within target. Some 97.1% of FLACS and 97.2% of MCS eyes had ≤1.0 D of AE (OR, 0.96; 95% CI, 0.57-1.60) and 49.3% of FLACS and 46.3% of MCS eyes, ≤0.25 D of AE (OR, 1.13; 95% CI, 0.91-1.39). Factors predictive of a favorable refractive outcome included axial length between 22 and 24.8 mm, receiving a toric intraocular lens, less preoperative cylinder, and greater preoperative average keratometry. There was no significant difference in the percentage of patients targeted for distance who achieved UDVA of 20/20 or better (P = 0.30), 20/25 or better (P = 0.06), or 20

  18. Evaluation of the shifting of the line of sight and higher order aberrations of eyes with keratoconus after corneal cross-linking.

    Science.gov (United States)

    Kosekahya, Pinar; Koc, Mustafa; Tekin, Kemal; Uzel, Murat; Atilgan, Cemile Ucgul; Caglayan, Mehtap; Yilmazbas, Pelin

    2017-10-01

    To evaluate changes in the coordinates of the line of sight (LoS) and higher order aberrations (HOAs) of eyes with keratoconus, following corneal cross-linking (CXL). All patients (93 eyes) underwent detailed ophthalmologic examination and Pentacam HR measurements at baseline and at 3, 6, and 12 months after corneal CXL. LoS coordinates on the horizontal (x) and vertical (y) axes, vertical coma, vertical trefoil, spherical aberration, total root-mean square (RMS), and HOA-RMS values were recorded along with visual acuity and topographical parameters. LoS significantly shifted to the nasal region after corneal CXL in both right and left eyes (p=0.003 and p=0.01, respectively). Horizontal axis values of both eyes significantly shifted to the temporal region at postoperative 6th months compared to the baseline measurements (p=0.02 and p=0.02, respectively) and remained the same between postoperative 6th months and 12th months (p=1.00 and p=0.97, respectively). Total-RMS, HOA-RMS, vertical coma, and spherical aberration values significantly improved after corneal CXL (pbaseline measurements (p=0.003, p=0.02, p0.05 for all values). The changes in horizontal-axis coordinates in left eyes were significantly correlated with anterior elevation, anterior astigmatism, total-RMS and HOA-RMS changes (r 2 =0.20, p=0.03; r 2 =0.35, pshifted to the nasal region and HOAs improved after corneal CXL and these changes stabilized 6th months after corneal CXL. It would be more better to perform refractive surgery in crosslinked corneas at least 6th months after corneal CXL. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Multimodal label-free ex vivo imaging using a dual-wavelength microscope with axial chromatic aberration compensation.

    Science.gov (United States)

    Filippi, Andrea; Dal Sasso, Eleonora; Iop, Laura; Armani, Andrea; Gintoli, Michele; Sandri, Marco; Gerosa, Gino; Romanato, Filippo; Borile, Giulia

    2018-03-01

    Label-free microscopy is a very powerful technique that can be applied to study samples with no need for exogenous fluorescent probes, keeping the main benefits of multiphoton microscopy, such as longer penetration depths and intrinsic optical sectioning while enabling serial multitechniques examinations on the same specimen. Among the many label-free microscopy methods, harmonic generation (HG) is one of the most intriguing methods due to its generally low photo-toxicity and relative ease of implementation. Today, HG and common two-photon microscopy (TPM) are well-established techniques, and are routinely used in several research fields. However, they require a significant amount of fine-tuning to be fully exploited, making them quite difficult to perform in parallel. Here, we present our designed multimodal microscope, capable of performing simultaneously TPM and HG without any kind of compromise thanks to two, separate, individually optimized laser sources with axial chromatic aberration compensation. We also apply our setup to the examination of a plethora of ex vivo samples to prove its capabilities and the significant advantages of a multimodal approach. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  20. Influence of DMSO on Carbon K ultrasoft X-rays induced chromosome aberrations in V79 Chinese hamster cells

    Energy Technology Data Exchange (ETDEWEB)

    Natarajan, Adayapalam T., E-mail: natarajan@live.nl [University of Tuscia, Viterbo (Italy); Palitti, Fabrizio [University of Tuscia, Viterbo (Italy); Hill, Mark A. [CRUK/MRC Gray Institute for Radiation Oncology and Biology, University of Oxford, Old Road Campus Research Building, Oxford OX3 7DQ (United Kingdom); MRC Radiation and Genome Stability Unit, Harwell, Oxfordshire OX11 0RD (United Kingdom); Stevens, David L. [MRC Radiation and Genome Stability Unit, Harwell, Oxfordshire OX11 0RD (United Kingdom); Ahnstroem, Gunnar [Department of Microbiology and Genetic Toxicology, Stockholm University, Stockholm (Sweden)

    2010-09-10

    Ultrasoft X-rays have been shown to be very efficient in inducing chromosomal aberrations in mammalian cells. The present study was aimed to evaluate the modifying effects of DMSO (a potent scavenger of free radicals) on the frequencies of chromosome aberrations induced by soft X-rays. Confluent held G1 Chinese hamster cells (V79) were irradiated with Carbon K ultrasoft X-rays in the presence and absence of 1 M DMSO and frequencies of chromosome aberrations in the first division cells were determined. DMSO reduced the frequencies of exchange types of aberrations (dicentrics and centric rings) by a factor of 2.1-3.5. The results indicate that free radicals induced by ultrasoft X-rays contribute to a great extent to the induction of chromosome aberrations. The possible implications of these results in interpreting the mechanisms involved in the high efficiency of ultrasoft X-rays in the induction of chromosome aberrations are discussed.

  1. Modification of Low Refractive Index Polycarbonate for High Refractive Index Applications

    Directory of Open Access Journals (Sweden)

    Gunjan Suri

    2009-01-01

    Full Text Available Polycarbonates and polythiourethanes are the most popular materials in use today, for optical applications. Polycarbonates are of two types which fall in the category of low refractive index and medium refractive index. The present paper describes the conversion of low refractive index polycarbonates into high refractive index material by the use of a high refractive index monomer, polythiol, as an additive. Novel polycarbonates, where the properties of refractive index and Abbe number can be tailor made, have been obtained. Thermal studies and refractive index determination indicate the formation of a new polymer with improved properties and suitable for optical applications.

  2. High-resolution study of photoinduced modification in fused silica produced by a tightly focused femtosecond laser beam in the presence of aberrations

    International Nuclear Information System (INIS)

    Hnatovsky, C.; Taylor, R.S.; Simova, E.; Bhardwaj, V.R.; Rayner, D.M.; Corkum, P.B.

    2005-01-01

    An ultrahigh-resolution (20 nm) technique of selective chemical etching and atomic force microscopy has been used to study the photoinduced modification in fused silica produced at various depths by tightly focused femtosecond laser radiation affected by spherical aberration. We demonstrate that shapes of the irradiated zones near the threshold for modification can be predicted by taking proper account of spherical aberration caused by the refractive index mismatched air-silica interface. We establish a depth dependence of the pulse energy required to initiate modification and characterize the relationship between numerical aperture of the writing lens and practically achievable writing depth. We also show that spatial characteristics of the laser-modified zones can be controlled by a specially designed focusing system which allows correction for a variable amount of spherical aberration

  3. Integrated Microfibre Device for Refractive Index and Temperature Sensing

    Directory of Open Access Journals (Sweden)

    Sulaiman W. Harun

    2012-08-01

    Full Text Available A microfibre device integrating a microfibre knot resonator in a Sagnac loop reflector is proposed for refractive index and temperature sensing. The reflective configuration of this optical structure offers the advantages of simple fabrication and ease of sensing. To achieve a balance between responsiveness and robustness, the entire microfibre structure is embedded in low index Teflon, except for the 0.5–2 mm diameter microfibre knot resonator sensing region. The proposed sensor has exhibited a linear spectral response with temperature and refractive index. A small change in free spectral range is observed when the microfibre device experiences a large refractive index change in the surrounding medium. The change is found to be in agreement with calculated results based on dispersion relationships.

  4. Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).

    Science.gov (United States)

    Wolfram, Christian; Höhn, René; Kottler, Ulrike; Wild, Philipp; Blettner, Maria; Bühren, Jens; Pfeiffer, Norbert; Mirshahi, Alireza

    2014-07-01

    To study the distribution of refractive errors among adults of European descent. Population-based eye study in Germany with 15010 participants aged 35-74 years. The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia +0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. 13959 subjects were eligible. Refractive errors ranged from -21.5 to +13.88 D. Myopia was present in 35.1% of this study sample, hyperopia in 31.8%, astigmatism in 32.3% and anisometropia in 13.5%. The prevalence of myopia decreased, while the prevalence of hyperopia, astigmatism and anisometropia increased with age. 3.5% of the study sample had no refractive correction for their ametropia. Refractive errors affect the majority of the population. The Gutenberg Health Study sample contains more myopes than other study cohorts in adult populations. Our findings do not support the hypothesis of a generally lower prevalence of myopia among adults in Europe as compared with East Asia.

  5. Nonlinear refraction at the absorption edge in InAs.

    Science.gov (United States)

    Poole, C D; Garmire, E

    1984-08-01

    The results of measurements of nonlinear refraction at the absorption edge in InAs between 68 and 90 K taken with an HF laser are compared with those of a band-gap resonant model in which the contribution of the light-hole band is included and found to account for more than 40% of the observed nonlinear refraction. A generalized expression for the nonlinear index is derived by using the complete Fermi-Dirac distribution function. Good agreement between theory and experiment is obtained, with no free parameters.

  6. Analysis on second operation after laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Wen-Xuan Pei

    2015-07-01

    Full Text Available AIM: To observe clinical effects between the laser in situ keratomileusis(LASIKsurgery and the laser subepithelial keratomileusis(LASEKsurgery as the second operation after an unsuccessful LASIK surgery. METHODS:Forty-nine patients(98 eyeswith refractive regression after LASIK operation received the second surgery. All patients were divided into two groups: group A and B. Group A(48 eyes of 24 patientsreceived LASIK surgery and group B(50 eyes of 25 patientsreceived LASEK surgery. Inspect the main parameters included visual acuity, refraction, corneal curvature, and the total value of high-aberration after 1wk, 1mo and 1a, t-test of groups was used as statistical analysis method.RESULTS: There was statistically significant(PP>0.05. There developed one case of epithelium in growth after LASIK surgery, and one case of haze Ⅱ after LASEK surgery. CONCLUSION: Both LASIK and LASEK surgery can obtain satisfactory therapeutic results after an unsuccessful LASIK surgery.

  7. Aberrant cervical thymus in an infant: an unusual cause of stridor

    International Nuclear Information System (INIS)

    Hammoud, D.A.; Khoury, N.J.; Haddad, M.C.

    2000-01-01

    We report an 8-month-old infant presenting with stridor caused by a nonpalpable neck mass discovered at imaging and surgery. The diagnosis of aberrant thymic tissue was confirmed at histopathology. The authors reviewed the literature and discuss the embryology, imaging findings and differential diagnosis of this rare disorder. (orig.)

  8. Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy.

    Science.gov (United States)

    Binding, Jonas; Ben Arous, Juliette; Léger, Jean-François; Gigan, Sylvain; Boccara, Claude; Bourdieu, Laurent

    2011-03-14

    Two-photon laser scanning microscopy (2PLSM) is an important tool for in vivo tissue imaging with sub-cellular resolution, but the penetration depth of current systems is potentially limited by sample-induced optical aberrations. To quantify these, we measured the refractive index n' in the somatosensory cortex of 7 rats in vivo using defocus optimization in full-field optical coherence tomography (ff-OCT). We found n' to be independent of imaging depth or rat age. From these measurements, we calculated that two-photon imaging beyond 200 µm into the cortex is limited by spherical aberration, indicating that adaptive optics will improve imaging depth.

  9. Dry Eye Epidemiology in Patients before Refractive Operations

    OpenAIRE

    S. N. Sakhnov; S. V. Yanchenko; A. V. Malyshev; Y. A. Kalantaevskaya; R. A. Ismaylova; E. M. Ehieva; M. V. Grishenko; I. V. Gorbunova; O. F. Ozhug; O. A. Klokova

    2018-01-01

    Purpose. To evaluate the prevalence, clinical severity, clinical and pathogenetic variants and etiology of dry eye (DE) in patientsbefore refractive surgery. Methods. OSDI testing, lipid interferential test, TBUT, Shirmer-1, -2 tests, compression Norn test in Korbmodification, calculation of xerosis index by Bijsterveld, tear meniscus index evaluation, LIPCOF test, evaluation of epitheliopaty and microerosion by Tseng and lid viper epitheliopaty were performed in 600 myopia (with or without a...

  10. Immediate free jejunum transfer for salvage surgery of gastric tube necrosis.

    Science.gov (United States)

    Umezawa, Hiroki; Matsutani, Takeshi; Ogawa, Rei; Hyakusoku, Hiko

    2014-01-01

    Gastric tube necrosis after esophagus cancer surgery is a rare but critical situation. Salvage reconstruction of the esophagus remains a challenging procedure for head and neck surgeons. Historically, surgeons have employed a two-stage salvage surgery consisting of debridement followed by reconstruction. While this procedure generates good results, the time to restart oral alimentation is long. The present report describes the case of a 62-year-old male who developed gastric tube necrosis 3 days after undergoing surgery for thoracic-cervical esophageal cancer and immediate reconstruction with the retrosternal gastric pullup technique. He was treated with debridement and simultaneous free jejunum transfer 4 days after the primary surgery. He was able to restart oral alimentation 10 days after the salvage surgery. This rapid return to oral alimentation is a major advantage of the one-stage immediate esophagus salvage reconstruction. Another advantage is the ease of the reconstructive procedure: the absence of scarring and prolonged inflammation, which are disadvantages of the two-stage procedure, meant that recipient vessel selection and anastomosis were uncomplicated. The one-step procedure may be particularly useful in cases where the inflammation is discovered early.

  11. Degenerações periféricas da retina em pacientes candidatos à cirurgia refrativa Peripheral retina degeneration in patients who are candidates for refractive surgery

    Directory of Open Access Journals (Sweden)

    Paulo Henrique de Avila Morales

    2001-02-01

    Full Text Available Objetivo: O objetivo desse estudo é verificar em indivíduos míopes candidatos à cirurgia refrativa a prevalência dos diferentes tipos de lesões retinianas periféricas degenerativas de acordo com o tipo de miopia. Métodos: De forma prospectiva, no período de um ano, foram examinados os olhos dos pacientes no Setor de Cirurgia Refrativa do Departamento de Oftalmologia da Universidade Federal de São Paulo - Escola Paulista de Medicina que durante a sua consulta inicial apresentassem refração com equivalente esférico superior ou igual a -1,00 dioptria esférica, e não tivessem antecedentes pessoais de doença ou cirurgia ocular no período. Foi investigada a existência de lesões e/ou degenerações periféricas predisponentes ao descolamento regmatogênico de retina. Resultados: O grupo foi composto, em sua maioria, por adultos jovens (média de idade de 31 anos. Foram observados olhos com miopia baixa (263 olhos, 31%, moderada (300 olhos, 36% e alta (277 olhos, 33%; em 35,4% dos pacientes (27% dos olhos foram encontradas degenerações periféricas, sendo o branco com e sem pressão a alteração mais freqüente (23,4% dos pacientes ou 17,5% dos olhos. Entre as lesões predisponentes ao descolamento regmatogênico da retina, a mais encontrada foi a degeneração em treliça (8,6% dos pacientes ou 6% dos olhos. Conclusões: As alterações periféricas predisponentes ou não ao descolamento regmatogênico de retina apresentaram aumento de prevalência de acordo com o aumento do grau de miopia, com exceção das roturas. Todos os pacientes com miopia alta e candidatos à cirurgia refrativa devem ter a periferia retiniana de ambos os olhos examinada.Purpose: To verify, in myopic individuals who are candidates for refractive surgery, the prevalence of different types of peripheral degenerative lesions of the retina, according to the type of myopia. Methods: Prospectively, during a one-year interval, we examined the eyes of patients in

  12. Functional and refractive results after one month of AcrySof toric intraocular lens implantation

    Directory of Open Access Journals (Sweden)

    Francisco Alba-Bueno

    2011-04-01

    Conclusions: The implantation of SN60T toric IOL in patients with CA higher than 0.75 D is a safe, predictable and effective way of reducing refractive astigmatism in patients undergoing cataract surgery.

  13. Negative Refraction in Rare-Earth Doped Crystals

    Science.gov (United States)

    2016-06-09

    in the material, which in turn refracts into free- space. The false- color plots in Fig. 10 show the snapshots for the electric field in the two spatial...M. Shelby, Homogeneous Line Broadening of Optical Transitions of Ions and Molecules in Glasses, J. Lumin. 36, 179 (1987). [20] B. S. Ham , P. R

  14. Aberrant right subclavian artery causing megaoesophagus in three cats.

    Science.gov (United States)

    Cinti, F; Della Santa, D; Borgonovo, S; Bussadori, R; Troiano, D; Pisani, G

    2018-05-07

    Three entire, domestic, shorthair male cats (age range: 3 months to 5 years) were referred because of regurgitation. Megaoesophagus attributable to aberrant right subclavian artery, originating from the aorta at the level of the fourth intercostal space, was diagnosed in all cats using thoracic radiography and CT angiography. One cat had concurrent patent ductus arteriosus with a normal aortic arch. Three-dimensional volume-rendered CT images were used to assess the malformations and to plan surgery for the treatment of the vascular anomalies. Different surgical approaches were used in the two kittens. The third cat was not operated. CT angiography is well suited for preoperative planning in cats with aberrant right subclavian artery alone or in combination with other vascular anomalies. © 2018 British Small Animal Veterinary Association.

  15. Spherical aberration correction with threefold symmetric line currents.

    Science.gov (United States)

    Hoque, Shahedul; Ito, Hiroyuki; Nishi, Ryuji; Takaoka, Akio; Munro, Eric

    2016-02-01

    It has been shown that N-fold symmetric line current (henceforth denoted as N-SYLC) produces 2N-pole magnetic fields. In this paper, a threefold symmetric line current (N3-SYLC in short) is proposed for correcting 3rd order spherical aberration of round lenses. N3-SYLC can be realized without using magnetic materials, which makes it free of the problems of hysteresis, inhomogeneity and saturation. We investigate theoretically the basic properties of an N3-SYLC configuration which can in principle be realized by simple wires. By optimizing the parameters of a system with beam energy of 5.5keV, the required excitation current for correcting 3rd order spherical aberration coefficient of 400 mm is less than 1AT, and the residual higher order aberrations can be kept sufficiently small to obtain beam size of less than 1 nm for initial slopes up to 5 mrad. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. [Analysis of aberration changes of the corneal anterior surface following discontinued use of rigid gas permeable contact lenses].

    Science.gov (United States)

    Yu, Qing; Wu, Jiang-xiu; Zhang, He-ning; Ye, Sheng; Dong, Shi-qi; Zhang, Chen-hao

    2011-04-01

    The present study used a corneal topographic device to record aberrations on the anterior surface of the cornea at different time-points prior to wearing and following discontinued use of rigid gas permeable (RGP) contact lenses. The effect of wearing RGPCL on the anterior surface of the cornea was discussed to provide guidance for clinical refractive error correction. The study objects were 60 eyes from 30 patients. All patients underwent identical examination procedures prior to lens use, as well as afterwards, including slit-lamp examination, non-contact tonometer measurement, computer optometry & corneal curvature measurement, subjective refraction test, and corneal topography analysis. The patients wore contact lenses every day for 1 month and then discontinued. Corneal topographies were recorded at certain time points of 30 min, 1 day, 3 days, 1 week, and 2 weeks following use. Total corneal aberration at each time point following discontinued use of RGP contact lenses was less than the time point prior to use. Detailed results are as follows; root mean square (RMS) (pre) = (1.438 ± 0.328), RMS (30 min) = (1.076 ± 0.355), RMS (1 day) = (1.362 ± 0.402), RMS (3 day) = (1.373 ± 0.398), RMS (7 day) = (1.387 ± 0.415), and RMS (14 day) = (1.448 ± 0.423). Results showed that at 30 minutes after discontinued use of RGP contact lenses, almost all 2(nd)- and 3(rd)-order aberrations were altered. Quadrafoil Z10 and spherical Z12 of the 4(th)-order were also changed. Alterations to Z5, Z6, and Z12 at 1 day after discontinued use were significant compared with the time period prior to RGP use: Z5 and Z6 decreased, and Z12 increased slightly (F = 2.869 ∼ 5.549, P = 0.001 ∼ 0.042). Z5 and Z6 remained decreased at 3 days after discontinued use, but Z9 and Z10 continued to increase and Z12 returned to levels prior to RGP use (P > 0.05). At 2 weeks after discontinued use, all aberrations were not significantly different from the values prior to use (P > 0.05). The

  17. Interocular differences in visual quality due to ocular aberrations and scattering in a patient with post-traumatic anisocoria: A case report

    Directory of Open Access Journals (Sweden)

    Andrés Gené-Sampedro

    2012-04-01

    Full Text Available A 41-year-old patient with visual disturbances after an ocular trauma in right eye three years before was carefully analyzed and discussed. No corneal or intraocular sequelae were present. Only a significant anisocoria could be observed. Right eye (RE achieved a best spectacle-corrected visual acuity (BSCVA of 0.05 LogMAR with a refraction of +0.50 sphere and −1.25 cylinder. Left eye (LE achieved a BSCVA of 0.0 LogMAR with a refraction of +0.75 sphere and −1.00 cylinder. In photopic conditions pupil diameter was 4.96 mm for RE and 3.02 mm for LE whereas in scotopic conditions, these values were 7.45 mm and 6.71 mm, respectively. More significant levels of higher-order corneal and ocular aberrations were found in RE for the same pupil size. In addition, the scattering index (OSI was 3.8 in RE and 1.0 in LE (4-mm pupil. In conclusion, anisocoria can lead to relevant visual disturbances if significant interocular differences in ocular aberrations and scattering are present.

  18. Nano-imprint gold grating as refractive index sensor

    International Nuclear Information System (INIS)

    Kumari, Sudha; Mohapatra, Saswat; Moirangthem, Rakesh S.

    2016-01-01

    Large scale of fabrication of plasmonic nanostructures has been a challenging task due to time consuming process and requirement of expensive nanofabrication tools such as electron beam lithography system, focused ion beam system, and extreme UV photolithography system. Here, we present a cost-effective fabrication technique so called soft nanoimprinting to fabricate nanostructures on the larger sample area. In our fabrication process, a commercially available optical DVD disc was used as a template which was imprinted on a polymer glass substrate to prepare 1D polymer nano-grating. A homemade nanoimprinting setup was used in this fabrication process. Further, a label-free refractive index sensor was developed by utilizing the properties of surface plasmon resonance (SPR) of a gold coated 1D polymer nano-grating. Refractive index sensing was tested by exposing different solutions of glycerol-water mixture on the surface of gold nano-grating. The calculated bulk refractive index sensitivity was found to be 751nm/RIU. We believed that our proposed SPR sensor could be a promising candidate for developing low-cost refractive index sensor with high sensitivity on a large scale.

  19. Heme Oxygenase-2 as a novel target to treat inflammation and chronic neuropathic pain associated with corneal injury and surgery

    OpenAIRE

    Marrazzo, Giuseppina

    2012-01-01

    Corneal refractive surgery aims at correcting alteration of the shape of the cornea correlated with myopia, hyperopia and astigmatism. More than 12 million patients have undergone refractive surgery since it was approved (see http://www. laser-eye-surgery statistics.com/). Laser-assisted in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) are the most used techniques to perform experimental corneal surgery. Several studies demonstrated that after epithelial removal (first...

  20. Femtosecond laser corneal refractive surgery for the correction of high myopic anisometropic amblyopia in juveniles

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    2017-11-01

    Full Text Available AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis (FS-LASIK and small-incision lenticule extraction (SMILE to correct high myopic anisometropic amblyopia in juvenile patients. METHODS: From November 2013 to January 2015, 33 amblyopic patients with high myopic anisometropic amblyopia were studied. FS-LASIK (30 eyes or SMILE (3 eyes was performed in the amblyopic eyes. Visual acuity, refraction, contrast sensitivity, stereoacuity and complications were evaluated. Patients completed follow-up examinations at 3d, 1mo, 3mo and the last follow-up time (mean 8.17±3.23mo after surgery. RESULTS: The mean age at surgery was 9.04±3.04y (range 6-16y. The mean spherical equivalent in the amblyopic eyes was significantly decreased from -10.00±2.39 D preoperatively to -0.06±1.06 D at 1mo, -0.19±1.33 D at 3mo and -0.60±1.43 D at approximately 8mo postoperatively (P<0.05 for all. The mean myopic anisometropia was significantly decreased from -9.45±2.33 D preoperatively to +0.37±1.48 D at 1mo, -0.46±1.47 D at 3mo and -0.09±1.83 D at approximately 8mo (P<0.05 for all. The logarithm of the minimum angle of resolution (logMAR for uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively of the amblyopic eye improved from 1.74±0.35 and 0.98±0.63 preoperatively to 0.45±0.31 and 0.41±0.33 at approximately 8mo after surgery, respectively. The logMAR CDVA at 3d, 1, 3 and 8mo postoperatively improved by means of 1.42, 2.22, 2.96, and 4.39 lines, and a gain of more than two lines accounted for 45%, 50%, 74% and 86% of all patients, respectively. The contrast sensitivity of both amblyopic eyes and dominant eyes at 0.5, 2, 8 cycles per degree was significantly improved postoperatively (P<0.05 for all. Of the 33 pediatric patients, no patients had near stereopsis preoperatively and seven patients (21.2% recovered near stereopsis (400″ to 60″ at approximately 8mo after surgery. No intraoperative or

  1. A web-based information system for management and analysis of patient data after refractive eye surgery.

    Science.gov (United States)

    Zuberbuhler, Bruno; Galloway, Peter; Reddy, Aravind; Saldana, Manuel; Gale, Richard

    2007-12-01

    The aim was to develop a software tool for refractive surgeons using a standard user-friendly web-based interface, providing the user with a secure environment to protect large volumes of patient data. The software application was named "Internet-based refractive analysis" (IBRA), and was programmed with the computer languages PHP, HTML and JavaScript, attached to the opensource MySQL database. IBRA facilitated internationally accepted presentation methods including the stability chart, the predictability chart and the safety chart; it was able to perform vector analysis for the course of a single patient or for group data. With the integrated nomogram calculation, treatment could be customised to reduce the postoperative refractive error. Multicenter functions permitted quality-control comparisons between different surgeons and laser units.

  2. Composition of the excimer laser-induced plume produced during LASIK refractive surgery

    Science.gov (United States)

    Glickman, Randolph D.; Liu, Yun; Mayo, George L.; Baribeau, Alan D.; Starck, Tomy; Bankhead, Tom

    2003-07-01

    Because of concerns about potential hazards to surgical personnel of the plume associated with laser refractive surgery, this study was performed to characterize the composition of such plumes. Filter elements were removed from the smoke evacuator of a VISX S3 excimer laser (filter pore size ~0.3 microns) and from a Mastel Clean Room ( filter pore size ~0.2 microns) used with a LADARVISION excimer laser. The filters from both laser systems captured the laser-induced plumes from multiple, routine, LASIK patient procedures. Some filters were processed for scanning electron microscopy, while others were extracted with methanol and chloroform for biochemical analysis. Both the VISX "Final Air" filter and the Mastel "Clean Room" filter captured material that was not observed in filters that had clean operating room air only passed through them. In the VISX system, air flows through the filter unit parallel to the filter matrix. SEM analysis showed these filters captured discrete particles of 0.3 to 3.0 microns in size. In the Mastel Clean Room unit, air flows orthogonally through the filter, and the filter matrix was heavily layered with captured debris so that individual particles were not readily distinguished. Amino acid analysis and gel electrophoresis of extracted material revealed proteinaceous molecules as large as 5000 molecular weight. Such large molecules in the laser plume are not predicted by the existing theory of photochemical ablation. The presence of relatively large biomolecules may constitute a risk of allergenic reactions in personnel exposed to the plume, and also calls into question the precise mechanism of excimer laser photochemical ablation. Supported by the RMG Research Endowment, and Research to Prevent Blindness

  3. Combining noncontingent reinforcement and differential reinforcement schedules as treatment for aberrant behavior.

    OpenAIRE

    Marcus, B A; Vollmer, T R

    1996-01-01

    Research has shown that noncontingent reinforcement (NCR) can be an effective behavior-reduction procedure when based on a functional analysis. The effects of NCR may be a result of elimination of the contingency between aberrant behavior and reinforcing consequences (extinction) or frequent and free access to reinforcers that may reduce the participant's motivation to engage in aberrant behaviors or mands. If motivation is momentarily reduced, behavior such as mands may not be sensitive to p...

  4. Propofol Effect on Stress Response and Free Radicals in Patient during Surgery and Sedation Procedure

    Directory of Open Access Journals (Sweden)

    Theresia Monica Rahardjo

    2015-12-01

    Full Text Available BACKGROUND: Propofol is an intravenous anesthetic used worldwide as an anesthesia induction and maintenance agent. Propofol also used as sedation agent in Intensive Care Unit (ICU. Despite it’s usual anesthesia properties, propofol has an unique pharmacologic characteristic, especially as antioxidant and stress response reduction. These advantages suggested propofol has positive effects when used as an anesthesia agent in surgery or sedation in ICU in conditions when high stress and free radical level are released. CONTENT: Stress response and free radical can be elevated in various conditions including surgery or during care in ICU, especially critical ill patient. Cortisol is a major stress hormone that influences metabolism, cardiovascular and central nervous system, either in acute or chronic phase. Oxidative stress was marked by free radical elevation called Radical Oxygen Species (ROS. Combination of both elements (cortisol and ROS can worsen patient condition. Propofol with anti-stress and antioxidant properties could be used to reduce stress response and attenuate free radical level in order to improve patient condition. SUMMARY: The anti-stress and antioxidant properties of Propofol are interesting, because these benefits can be added as adjunctive therapy when propofol was used as an anesthetic agent in surgery and a sedation in ICU. KEYWORDS: propofol, stress response, antioxidant.

  5. Applying field mapping refractive beam shapers to improve holographic techniques

    Science.gov (United States)

    Laskin, Alexander; Williams, Gavin; McWilliam, Richard; Laskin, Vadim

    2012-03-01

    Performance of various holographic techniques can be essentially improved by homogenizing the intensity profile of the laser beam with using beam shaping optics, for example, the achromatic field mapping refractive beam shapers like πShaper. The operational principle of these devices presumes transformation of laser beam intensity from Gaussian to flattop one with high flatness of output wavefront, saving of beam consistency, providing collimated output beam of low divergence, high transmittance, extended depth of field, negligible residual wave aberration, and achromatic design provides capability to work with several laser sources with different wavelengths simultaneously. Applying of these beam shapers brings serious benefits to the Spatial Light Modulator based techniques like Computer Generated Holography or Dot-Matrix mastering of security holograms since uniform illumination of an SLM allows simplifying mathematical calculations and increasing predictability and reliability of the imaging results. Another example is multicolour Denisyuk holography when the achromatic πShaper provides uniform illumination of a field at various wavelengths simultaneously. This paper will describe some design basics of the field mapping refractive beam shapers and optical layouts of their applying in holographic systems. Examples of real implementations and experimental results will be presented as well.

  6. Determination of aberration center of Ronchigram for automated aberration correctors in scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Sannomiya, Takumi, E-mail: sannomiya@mtl.titech.ac.jp [Tokyo Institute of Technology, Ookayama, Tokyo (Japan); Sawada, Hidetaka; Nakamichi, Tomohiro; Hosokawa, Fumio [JEOL Limited, Akishima, Tokyo (Japan); Nakamura, Yoshio; Tanishiro, Yasumasa; Takayanagi, Kunio [Tokyo Institute of Technology, Ookayama, Tokyo (Japan)

    2013-12-15

    A generic method to determine the aberration center is established, which can be utilized for aberration calculation and axis alignment for aberration corrected electron microscopes. In this method, decentering induced secondary aberrations from inherent primary aberrations are minimized to find the appropriate axis center. The fitness function to find the optimal decentering vector for the axis was defined as a sum of decentering induced secondary aberrations with properly distributed weight values according to the aberration order. Since the appropriate decentering vector is determined from the aberration values calculated at an arbitrary center axis, only one aberration measurement is in principle required to find the center, resulting in /very fast center search. This approach was tested for the Ronchigram based aberration calculation method for aberration corrected scanning transmission electron microscopy. Both in simulation and in experiments, the center search was confirmed to work well although the convergence to find the best axis becomes slower with larger primary aberrations. Such aberration center determination is expected to fully automatize the aberration correction procedures, which used to require pre-alignment of experienced users. This approach is also applicable to automated aperture positioning. - Highlights: • A generic method to determine the aberration center is established for (S)TEM. • Decentering induced secondary aberrations are utilized to find the center. • The method is tested on Ronchigrams both in simulation and experiment. • Proper weighting of the aberration gives a good convergence. • Larger primary aberration results in a slower convergence.

  7. Comparison of objective refraction in darkness to cycloplegic refraction: a pilot study.

    Science.gov (United States)

    Vasudevan, Balamurali; Ciuffreda, Kenneth J; Meehan, Kelly; Grk, Dejana; Cox, Misty

    2016-03-01

    The aim was to assess non-cycloplegic objective refraction in darkness using an open-field auto-refractor, and furthermore to compare it with distance cycloplegic subjective refraction and distance cycloplegic retinoscopy in the light, in children and young adults. Twenty-three, visually-normal, young-adults (46 eyes) ages 23 to 31 years, and five children (10 eyes) ages five to 12 years, participated in the study. The spherical component of their refraction ranged from -2.25 D to +3.75 D with a mean of +1.80 D, and a mean cylinder of -0.70 D. Three techniques were used to assess refractive error. An objective measure of the non-cycloplegic refractive state was obtained using an open-field autorefractor (WAM-5500) after five minutes in the dark to allow for dissipation of accommodative transients and relaxation of accommodation. In addition, both distance retinoscopy and subjective distance refraction were performed following cycloplegia (Cyclopentolate, 1%) using conventional clinical procedures. All measurements were obtained on the same day within a single session. The spherical component of the refraction was compared among the three techniques in both the children and adults. There was no significant difference in spherical refraction among the three techniques: non-cycloplegic objective refraction in the dark, distance cycloplegic retinoscopy and distance cycloplegic subjective refraction, in either the adults [F(2, 137) = 0.79, p = 0.45] or the children [F(2, 27) = 0.47, p = 0.62]. Mean difference in the spherical component between refraction in the dark and the cycloplegic distance retinoscopy was -0.34 D (r = 0.89) in the adults and +0.14 D (r = 0.96) in the children. The mean difference in spherical component between refraction in the dark and the cycloplegic distance subjective refraction was -0.25 D (r = 0.92) in the adults and -0.05 D (r = 0.95) in the children. Comparison of the spherical refractive component between the three techniques was not

  8. Refractive neutron lens

    International Nuclear Information System (INIS)

    Petrov, P.V.; Kolchevsky, N.N.

    2013-01-01

    Model of the refractive neutron lens is proposed. System of N lenses acts as one thin lens with a complex refraction index n*. The maximum number N max of individual lenses for 'thick' neutron lens is calculated. Refractive neutron lens properties (resolution, focal depth) as function of resolution factor F 0 =ρbc/μ and depth of field factor dF 0 =λF 0 =λρbc/μ are calculated. It is shown that micro resolution of the refractive neutron optics is far from the wavelength in size and its open possibilities for progress in refractive neutron optics. (authors)

  9. Military target task performance after wavefront-guided (WFG) and wavefront-optimized (WFO) photorefractive keratectomy (PRK)

    Science.gov (United States)

    Maurer, Tana; Deaver, Dawne; Howell, Christopher; Moyer, Steve; Nguyen, Oanh; Mueller, Greg; Ryan, Denise; Sia, Rose K.; Stutzman, Richard; Pasternak, Joseph; Bower, Kraig

    2014-06-01

    Major decisions regarding life and death are routinely made on the modern battlefield, where visual function of the individual soldier can be of critical importance in the decision-making process. Glasses in the combat environment have considerable disadvantages: degradation of short term visual performance can occur as dust and sweat accumulate on lenses during a mission or patrol; long term visual performance can diminish as lenses become increasingly scratched and pitted; during periods of intense physical trauma, glasses can be knocked off the soldier's face and lost or broken. Although refractive surgery offers certain benefits on the battlefield when compared to wearing glasses, it is not without potential disadvantages. As a byproduct of refractive surgery, elevated optical aberrations can be induced, causing decreases in contrast sensitivity and increases in the symptoms of glare, halos, and starbursts. Typically, these symptoms occur under low light level conditions, the same conditions under which most military operations are initiated. With the advent of wavefront aberrometry, we are now seeing correction not only of myopia and astigmatism but of other, smaller optical aberrations that can cause the above symptoms. In collaboration with the Warfighter Refractive Eye Surgery Program and Research Center (WRESP-RC) at Fort Belvoir and Walter Reed National Military Medical Center (WRNMMC), the overall objective of this study is to determine the impact of wavefront guided (WFG) versus wavefront-optimized (WFO) photorefractive keratectomy (PRK) on military task visual performance. Psychophysical perception testing was conducted before and after surgery to measure each participant's performance regarding target detection and identification using thermal imagery. The results are presented here.

  10. Postoperative ocular higher-order aberrations and contrast sensitivity: femtosecond lenticule extraction versus pseudo small-incision lenticule extraction.

    Science.gov (United States)

    Tan, Deborah K L; Tay, Wan Ting; Chan, Cordelia; Tan, Donald T H; Mehta, Jodhbir S

    2015-03-01

    To evaluate and compare changes in contrast sensitivity and ocular higher-order aberrations (HOAs) after femtosecond lenticule extraction (FLEx) and pseudo small-incision lenticule extraction (SMILE). Singapore National Eye Centre, Singapore. Retrospective case series. Patients had femtosecond lenticule extraction (Group 1) or pseudo small-incision lenticule extraction (Group 2) between March 2010 and December 2011. The main outcome measures were manifest refraction, HOAs, and contrast sensitivity 1, 3, 6, and 12 months postoperatively. Fifty-two consecutive patients (102 eyes) were recruited, 21 patients (42 eyes) in Group 1 and the 31 patients (60 eyes) in Group 2. The uncorrected and corrected distance visual acuities were significantly better in Group 2 than in Group 1 at 12 months (P = .032). There was no significant increase in 3rd- or 4th-order aberrations at 1 year and no significant difference between the 2 groups preoperatively or postoperatively. At 1 year, there was a significant increase in mesopic contrast sensitivity in Group 2 at 1.5 cycles per degree (cpd) (P = .008) that was not found in Group 1, and photopic contrast sensitivity at 6.0 cpd was higher in Group 2 (P = .027). These results indicate that refractive lenticule extraction is safe and effective with no significant induction of HOAs or deterioration in contrast sensitivity at 1 year. Induction of HOAs was not significantly different between both variants of refractive lenticule extraction. However, there was significant improvement in photopic contrast sensitivity after pseudo small-incision lenticule extraction, which persisted through 1 year. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    Science.gov (United States)

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  12. The Use of Harmonic Scalpel for Free Flap Dissection in Head and Neck Reconstructive Surgery

    Directory of Open Access Journals (Sweden)

    Sebastien Albert

    2012-01-01

    Full Text Available Surgeons conventionally use electrocautery dissection and surgical clip appliers to harvest free flaps. The ultrasonic Harmonic Scalpel is a new surgical instrument that provides high-quality dissection and hemostasis and minimizes tissue injury. The aim of this study was to evaluate the effectiveness and advantages of the ultrasonic Harmonic Scalpel compared to conventional surgical instruments in free flap surgery. This prospective study included 20 patients who underwent head and neck reconstructive surgery between March 2009 and May 2010. A forearm free flap was used for reconstruction in 12 patients, and a fibular flap was used in 8 patients. In half of the patients, electrocautery and surgical clips were used for free flap harvesting (the EC group, and in the other half of the patients, ultrasonic dissection was performed using the Harmonic Scalpel (the HS group. The following parameters were significantly lower in the HS group compared to the EC group: the operative time of flap dissection (35% lower in the HS group, blood loss, number of surgical clips and cost of surgical materials. This study demonstrated the effectiveness of the Harmonic Scalpel in forearm and fibular free flap dissections that may be extended to other free flaps.

  13. [Surgery guided by customized devices: reconstruction with a free fibula flap].

    Science.gov (United States)

    Schouman, T; Bertolus, C; Chaine, C; Ceccaldi, J; Goudot, P

    2014-02-01

    The reconstruction of jaws with a free fibula flap can be anticipated virtually. The simulation can be transferred to the operating theater using customized devices obtained from computer-assisted design and manufacturing in a complete digital workflow. Several alternatives are available, from cutting guides to customized titanium osteosynthesis plates, to obtain the best accuracy and reproducibility of reconstruction. Moreover, these new processes allow integrating prosthetic planning concomitantly with reconstruction. We present the virtual three-dimensional planning method for jaw reconstruction with a free fibula flap and the various alternatives of surgery guided by customized devices provided by this planning. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  14. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    Science.gov (United States)

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  15. Transient structural distortion of metal-free Cu/Zn superoxide dismutase triggers aberrant oligomerization

    DEFF Research Database (Denmark)

    Teilum, Kaare; Smith, Melanie H; Schulz, Eike

    2009-01-01

    remained enigmatic, however, as is the case in other protein-misfolding diseases. Here, we target the critical conformational change that defines the earliest step toward aggregation. Using nuclear spin relaxation dispersion experiments, we identified a short-lived (0.4 ms) and weakly populated (0.......7%) conformation of metal-depleted SOD1 that triggers aberrant oligomerization. This excited state emanates from the folded ground state and is suppressed by metal binding, but is present in both the disulfide-oxidized and disulfide-reduced forms of the protein. Our results pinpoint a perturbed region......Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease linked to the misfolding of Cu/Zn superoxide dismutase (SOD1). ALS-related defects in SOD1 result in a gain of toxic function that coincides with aberrant oligomerization. The structural events triggering oligomerization have...

  16. Laser parameters, focusing optics, and side effects in femtosecond laser corneal surgery

    Science.gov (United States)

    Plamann, Karsten; Nuzzo, Valeria; Peyrot, Donald A.; Deloison, Florent; Savoldelli, Michèle; Legeais, Jean-Marc

    2008-02-01

    Nowadays, femtosecond lasers are routinely used in refractive eye surgery. Until recently, commercialised clinical systems were exclusively based on ytterbium or neodymium-doped solid state lasers emitting sub-picosecond pulses at a wavelength of about 1 μm and repetition rates of a few 10 kHz. These systems use pulse energies in the μJ range and focussing optics of NA = 0.3 to 0.5. Recent developments have provided a variety of alternative and equally viable approaches: systems are now available using nJ pulses at high numerical apertures and MHz repetition rates - an approach so far only used for femtosecond cell surgery - and fibre laser technology is now being used for femtosecond laser corneal surgery. Recent research has also provided more insight in side effects occurring in present systems: self focusing phenomena and so far unexplained periodical structures have been observed even at high numerical apertures (NA >> 0.5) and moderate pulse energies. The interaction of femtosecond laser pulses with strongly scattering tissue has been studied in view of extending the application of femtosecond lasers to keratoplasty for opaque corneas and to glaucoma surgery. The use of new laser wavelengths and adaptive optics has been proposed. Despite the reputation of femtosecond surgical systems for their precision, repeatability and the absence of secondary effects or complications, a closer examination reveals the presence of subtle phenomena which merit further investigation. We present three of these phenomena: the influence of optical aberration on the quality of the incision, the occurrence of filamentation effects, and the deposit of microscopic glass fragments when performing penetrating incisions.

  17. Estudo dos movimentos torcionais em cirurgia refrativa Study of torsional movements in refractive surgery

    Directory of Open Access Journals (Sweden)

    Guilherme José Nunes Marques Rocha

    2005-12-01

    Full Text Available OBJETIVO: Verificar a ocorrência de movimentos torcionais do globo ocular no momento da cirurgia refrativa em pacientes astigmatas e suas possíveis conseqüências no resultado da cirurgia. MÉTODOS: Estudo prospectivo de 49 olhos de 40 pacientes atendidos no Hospital de Olhos do Paraná, portadores de astigmatismo, e que seriam submetidos à cirurgia refrativa. A técnica cirúrgica utilizada em todos os pacientes foi o LASIK. Os pacientes foram divididos em dois grupos, de acordo com o poder do astigmatismo, que variou no primeiro grupo 0,25 a 2,00D; e no segundo grupo de 2,25 a 6,00D. Todos os pacientes foram examinados para avaliar a ocorrência de torção do globo ocular no momento da cirurgia, e com base nestes dados foi corrigido o eixo do tratamento por meio de programa específico do aparelho de laser. Os resultados dos dois grupos foram analisados e comparados estatisticamente. Os resultados foram relacionados com os dados existentes sobre influência da variação do eixo do tratamento com o resultado da cirurgia. RESULTADOS: Observou-se torção média de 3,5º+/- no grupo A; e de 4,5º+/- no grupo B. Não houve diferença estatística significativa entre os grupos. CONCLUSÕES: Os movimentos torcionais ocorrem de forma significativa em quase todos os pacientes submetidos à cirurgia refrativa e portanto, devem ser sempre corrigidos para se evitar redução na eficiência do tratamento. Isto é especialmente importante nos casos de cirurgia personalizada.PURPOSE: To observe torsional movements of the eye in refractive surgery, and their possible consequences in the surgery outcome. METHODS: In a prospective study, 49 eyes of 40 patients were submitted to surgical correction of astigmatism, by the LASIK technique. Patients were divided in two groups based on the cylindric power. Group A from -0.25 to -2.00D; group B from -2.25 to -6.00D. The occurrence of torsional movements was recorded in all patients, and based on this, the axis

  18. Clinical study of the clusters of diffuse lamellar keratitis after laser corneal refractive surgery

    Directory of Open Access Journals (Sweden)

    Qing-Hong Lin

    2017-06-01

    Full Text Available AIM: To investigate the potential causes and management of the clusters of diffuse lamellar keratitis(DLKafter laser corneal refractive surgery. METHODS: The study enrolled 98 eyes(53 patientscomplicated with DLK after receiving laser in situ keratomileusis(LASIK, FS-LASIK or small-incision lenticule extraction(SMILEin our center from February 10th,2016 to February 22th,2016. They were given clinical classification treatments according to corneal layer inflammatory extent and then followed up after 1, 3, 5, 7, 10d and 1mo. RESULTS: The clusters of DLK occurred 5 times in the study period. The incidence and degree of DLK significantly decreased after changed the sterilization, surgical equipments, temperature and humidity of the operating room. There were 80 eyes(82%had stage 1 DLK, 11 eyes(11%had stage 2, 4 eyes(4%had stage 3 and 3 eyes(3%had stage 4. The incidence of DLK after FS-LASIK was 40%(79 eyes in 42 patients, that after LASIK assistant by Hastome keratome was 45%(10 eyes in 5 patients, that after SMILE was 20%(9 eyes in 6 patients. After intensive treatment, as glucocorticoid treatment and flap lifting flushing, all cases recovered within 1mo. CONCLUSION: The outbreak of DLK may be associated with the disposable item, flushing liquor, temperature and humidity of the operating room. Early diagnosis, prevention and treatment are the key of decreasing the incidence of DLK.

  19. Refractive errors in children and adolescents in Bucaramanga (Colombia).

    Science.gov (United States)

    Galvis, Virgilio; Tello, Alejandro; Otero, Johanna; Serrano, Andrés A; Gómez, Luz María; Castellanos, Yuly

    2017-01-01

    The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia). This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D). Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.

  20. Refractive errors in children and adolescents in Bucaramanga (Colombia

    Directory of Open Access Journals (Sweden)

    Virgilio Galvis

    Full Text Available ABSTRACT Purpose: The aim of this study was to establish the frequency of refractive errors in children and adolescents aged between 8 and 17 years old, living in the metropolitan area of Bucaramanga (Colombia. Methods: This study was a secondary analysis of two descriptive cross-sectional studies that applied sociodemographic surveys and assessed visual acuity and refraction. Ametropias were classified as myopic errors, hyperopic errors, and mixed astigmatism. Eyes were considered emmetropic if none of these classifications were made. The data were collated using free software and analyzed with STATA/IC 11.2. Results: One thousand two hundred twenty-eight individuals were included in this study. Girls showed a higher rate of ametropia than boys. Hyperopic refractive errors were present in 23.1% of the subjects, and myopic errors in 11.2%. Only 0.2% of the eyes had high myopia (≤-6.00 D. Mixed astigmatism and anisometropia were uncommon, and myopia frequency increased with age. There were statistically significant steeper keratometric readings in myopic compared to hyperopic eyes. Conclusions: The frequency of refractive errors that we found of 36.7% is moderate compared to the global data. The rates and parameters statistically differed by sex and age groups. Our findings are useful for establishing refractive error rate benchmarks in low-middle-income countries and as a baseline for following their variation by sociodemographic factors.

  1. Possible mechanisms of chromosome aberrations. 2. Formation of aberrations after UV-irradiation

    International Nuclear Information System (INIS)

    Lebedeva, L.I.

    1982-01-01

    One of mechanisms of chromosome aberrations after UV-radiation of animal cells initiated by thymine dimerization from different dna threads (by cross joints) and finished in mitosis metaphase is discussed. The model of aberration formation, taking a count of peculiarities of chromosome ansate structure and predicting the important role of chromosome isolation during mitosis in realization of structural aberrations, is suggested. An attempt to present aberration formation under conditions of exact repair is the distinguishing feature of the model

  2. Prosthetic Rehabilitation After Fibular Free Flap Surgery of Mandibular Defects in a Patient With Oral Squamous Cell Carcinoma.

    Science.gov (United States)

    Yoon, Hyung-In

    2016-10-01

    This report is to present the treatment procedure and clinical considerations of prosthodontic management of a patient who had undergone a partial mandibulectomy and fibular free flap surgery. A 59-year-old man with a squamous cell carcinoma received a partial mandibular resection. Microsurgical reconstruction with a fibular free flap surgery and implant-supported zirconia-fixed prosthesis produced by computer-aided manufacturing led to successful results for the oral rehabilitation of mandibular defects. The implant-supported zirconia-fixed prosthesis can be recommended for use in patients with mandibulectomy and fibular free flaps. Close cooperation between the surgeon and the prosthodontist is mandatory for the satisfaction of the patient.

  3. Graphical Approach to Fresnel's Equations for Reflection and Refraction of Light.

    Science.gov (United States)

    Doyle, William T.

    1980-01-01

    Develops a coordinate-free approach to Fresnel's equations for the reflection and refraction of light at a plane interface. Describes a graphical construction for finding the vector amplitudes of the reflected and transmitted waves. (Author/CS)

  4. Low-energy foil aberration corrector

    International Nuclear Information System (INIS)

    Aken, R.H. van; Hagen, C.W.; Barth, J.E.; Kruit, P.

    2002-01-01

    A spherical and chromatic aberration corrector for electron microscopes is proposed, consisting of a thin foil sandwiched between two apertures. The electrons are retarded at the foil to almost zero energy, so that they can travel ballistically through the foil. It is shown that such a low-voltage corrector has a negative spherical aberration for not too large distances between aperture and foil, as well as a negative chromatic aberration. For various distances the third- and fifth-order spherical aberration coefficients and the first- and second-order chromatic aberration coefficients are calculated using ray tracing. Provided that the foils have sufficient electron transmission the corrector is able to correct the third-order spherical aberration and the first-order chromatic aberration of a typical low-voltage scanning electron microscope. Preliminary results show that the fifth-order spherical aberration and the second-order chromatic aberration can be kept sufficiently low

  5. RADIO REFRACTIVITY RADIO REFRACTIVITY STUDY IN AKURE ...

    African Journals Online (AJOL)

    eobe

    Propagation of waves in a microwave link is through the troposphere which is the non-ionized lowest portion of the atmosphere [5]. The refractive index is defined as [5]. (1). Where εr is the dielectric constant of the troposphere. C is the speed of light and V is the phase velocity of the wave in the medium. The refractive index ...

  6. Uncorrected refractive errors.

    Science.gov (United States)

    Naidoo, Kovin S; Jaggernath, Jyoti

    2012-01-01

    Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC), were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR) Development, Service Development and Social Entrepreneurship.

  7. Uncorrected refractive errors

    Directory of Open Access Journals (Sweden)

    Kovin S Naidoo

    2012-01-01

    Full Text Available Global estimates indicate that more than 2.3 billion people in the world suffer from poor vision due to refractive error; of which 670 million people are considered visually impaired because they do not have access to corrective treatment. Refractive errors, if uncorrected, results in an impaired quality of life for millions of people worldwide, irrespective of their age, sex and ethnicity. Over the past decade, a series of studies using a survey methodology, referred to as Refractive Error Study in Children (RESC, were performed in populations with different ethnic origins and cultural settings. These studies confirmed that the prevalence of uncorrected refractive errors is considerably high for children in low-and-middle-income countries. Furthermore, uncorrected refractive error has been noted to have extensive social and economic impacts, such as limiting educational and employment opportunities of economically active persons, healthy individuals and communities. The key public health challenges presented by uncorrected refractive errors, the leading cause of vision impairment across the world, require urgent attention. To address these issues, it is critical to focus on the development of human resources and sustainable methods of service delivery. This paper discusses three core pillars to addressing the challenges posed by uncorrected refractive errors: Human Resource (HR Development, Service Development and Social Entrepreneurship.

  8. Effectiveness and comfort of Oculus Keratograph on tear film function test before corneal refractive surgery

    Directory of Open Access Journals (Sweden)

    Peng Zhang

    2017-08-01

    Full Text Available AIM: To explore correlation, consistency and comfort between traditional tear film examination methods and Oculus Keratograph. METHODS: A retrospective study. Totally 101 cases(101 eyeswere diagnosed myopia and then accepted LASEK(laser epithelial keratomileusis. Non-invasive tear film break-up time(NIBUT, lower tear meniscus height(LTMHwere measured with Oculus Keratograph, fluorescein tear film break-up time(fl-BUTand Schimer Ⅰ test(SⅠtwere performed on all cases. The correlations analysis between NIBUT and fl-BUT, LTMH and SⅠt were performed by Spearman rank correlation, consistency check between NIBUT and fl-BUT by Bland-Altman analysis. Visual analogue scale(VASwas applied on evaluating the comfort of two kinds of examination methods. RESULTS: LTMH and SⅠt showed positive correlation(rs=0.346, P=0.001. NIBUT and fl-BUT showed positive correlation(rs=0.393, P=0.001, 95% consistency limits range -9.62 to 14.18 in Bland-Altman Figure. There was significant difference between VAS of NIBUT and VAS of fl-BUT(z=-2.324, P=0.020. There was significant difference between VAS of LTMH and VAS of SⅠt(z=-8.845,P=0.001.CONCLUSION: Oculus Keratograph can objectively measure NIBUT and LTMH, and was more comfortable than traditional tear film examination methods. It can effectively assess tear film function before corneal refractive surgery.

  9. Automatic phase aberration compensation for digital holographic microscopy based on deep learning background detection.

    Science.gov (United States)

    Nguyen, Thanh; Bui, Vy; Lam, Van; Raub, Christopher B; Chang, Lin-Ching; Nehmetallah, George

    2017-06-26

    We propose a fully automatic technique to obtain aberration free quantitative phase imaging in digital holographic microscopy (DHM) based on deep learning. The traditional DHM solves the phase aberration compensation problem by manually detecting the background for quantitative measurement. This would be a drawback in real time implementation and for dynamic processes such as cell migration phenomena. A recent automatic aberration compensation approach using principle component analysis (PCA) in DHM avoids human intervention regardless of the cells' motion. However, it corrects spherical/elliptical aberration only and disregards the higher order aberrations. Traditional image segmentation techniques can be employed to spatially detect cell locations. Ideally, automatic image segmentation techniques make real time measurement possible. However, existing automatic unsupervised segmentation techniques have poor performance when applied to DHM phase images because of aberrations and speckle noise. In this paper, we propose a novel method that combines a supervised deep learning technique with convolutional neural network (CNN) and Zernike polynomial fitting (ZPF). The deep learning CNN is implemented to perform automatic background region detection that allows for ZPF to compute the self-conjugated phase to compensate for most aberrations.

  10. EDITORIAL: Sensitive structures: refractive indices in nanotechnology Sensitive structures: refractive indices in nanotechnology

    Science.gov (United States)

    Demming, Anna

    2012-12-01

    Refractive index effects using nanoscale systems are frequently applied in new imaging, sensing and even visibility cloaking technology. In this issue, researchers in Japan use simulations and experiments to describe the confinement of optical vortices in nanoscale fin structures and the sensitivity of these systems to the refractive index of the surrounding media [1]. The effects of refraction as light rays pass between different media were recorded as long ago as the first century AD, by Ptolemy [2]. Over the following centuries the phenomena inspired Ibn Sahl in 984 [3], Thomas Harriot in 1602 [4], Willebrord Snellius in 1621 [5] and Rene Descartes in 1637 [6] to independently derive the more accurate and elegant equation for refraction so familiar to us today. Recent studies of the interactions between light and matter continue to reveal a wealth of phenomena that originate in the effects of the refractive indices of materials. Nanostructures can be used to manipulate conditions that affect the refractive indices of materials, such as temperature. A E Aliev et al at the University of Texas reported a striking demonstration of temperature-dependent refractive index effects using a free-standing, highly aligned carbon nanotube aerogel sheet [7]. They used the extremely low thermal capacitance and high heat transfer ability of transparent carbon nanotube sheets to enable high-frequency modulation of the sheet temperature over an enormous temperature range. The resulting sharp, rapidly changing gradient of the refractive index in the surrounding liquid or gas makes objects seem to disappear and can be used for visibility cloaking. Light-matter interaction resonances, where light is confined at the nanoscale, can be extremely sensitive to changes in the refractive index of the surrounding media [8], even allowing single-molecule detection [9]. Plasmons, the collective oscillations of electrons in response to incident light, are a typical example. Researchers at Rice

  11. A comparison of preservative-free diclofenac and preserved diclofenac eye drops after cataract surgery in patients with diabetic retinopathy.

    Science.gov (United States)

    Yasuda, Kanako; Miyazawa, Akiko; Shimura, Masahiko

    2012-06-01

    The aim of this study was to compare the anti-inflammatory efficacy of preservative-free and preserved 0.1% diclofenac eye drops for the management of postoperative inflammation after cataract surgery in patients with nonproliferative diabetic retinopathy and in normal controls. Forty-two diabetic patients and 50 normal control patients who underwent small-incision phacoemulsification cataract surgery bilaterally received topical preservative-free diclofenac in 1 eye and preserved diclofenac in the other eye. The corrected distance visual acuity (CDVA) as determined by a logarithm of the minimum angle of resolution (logMAR) chart, intraocular pressure (IOP), foveal thickness (FT) using optical coherence tomography (OCT), and the anterior chamber flare (ACF) score measured with a laser flare cell meter were monitored for 12 weeks after surgery. In the eyes with diabetic retinopathy, there were no significant differences in CDVA, IOP, FT, and ACF score between the right and left eyes at the initial exam. After cataract surgery, changes in CDVA, IOP, and FT were not influenced by the preservative in the diclofenac eye drops. In contrast, the ACF score in the eyes treated with preserved diclofenac showed slower recovery from postoperative inflammation than the eyes treated with preservative-free diclofenac. In the normal control eyes, similar but milder changes were observed in each of the clinical parameters. Because preservative suppressed the anti-inflammatory efficacy of topical diclofenac after cataract surgery, preservative-free diclofenac may have an improved safety profile during postoperative treatment, especially in patients with diabetic retinopathy.

  12. All-angle negative refraction and active flat lensing of ultraviolet light.

    Science.gov (United States)

    Xu, Ting; Agrawal, Amit; Abashin, Maxim; Chau, Kenneth J; Lezec, Henri J

    2013-05-23

    Decades ago, Veselago predicted that a material with simultaneously negative electric and magnetic polarization responses would yield a 'left-handed' medium in which light propagates with opposite phase and energy velocities--a condition described by a negative refractive index. He proposed that a flat slab of left-handed material possessing an isotropic refractive index of -1 could act like an imaging lens in free space. Left-handed materials do not occur naturally, and it has only recently become possible to achieve a left-handed response using metamaterials, that is, electromagnetic structures engineered on subwavelength scales to elicit tailored polarization responses. So far, left-handed responses have typically been implemented using resonant metamaterials composed of periodic arrays of unit cells containing inductive-capacitive resonators and conductive wires. Negative refractive indices that are isotropic in two or three dimensions at microwave frequencies have been achieved in resonant metamaterials with centimetre-scale features. Scaling the left-handed response to higher frequencies, such as infrared or visible, has been done by shrinking critical dimensions to submicrometre scales by means of top-down nanofabrication. This miniaturization has, however, so far been achieved at the cost of reduced unit-cell symmetry, yielding a refractive index that is negative along only one axis. Moreover, lithographic scaling limits have so far precluded the fabrication of resonant metamaterials with left-handed responses at frequencies beyond the visible. Here we report the experimental implementation of a bulk metamaterial with a left-handed response to ultraviolet light. The structure, based on stacked plasmonic waveguides, yields an omnidirectional left-handed response for transverse magnetic polarization characterized by a negative refractive index. By engineering the structure to have a refractive index close to -1 over a broad angular range, we achieve Veselago

  13. Silicon photonic crystal nanostructures for refractive index sensing

    DEFF Research Database (Denmark)

    Dorfner, Dominic; Hürlimann, T.; Zabel, T.

    2008-01-01

    The authors present the fabrication and optical investigation of Silicon on Insulator photonic crystal drop-filters for use as refractive index sensors. Two types of defect nanocavities (L3 and H1-r) are embedded between two W1 photonic crystal waveguides to evanescently route light at the cavity...... mode frequency between input and output waveguides. Optical characterization of the structures in air and various liquids demonstrate detectivities in excess of n=n = 0:018 and n=n = 0:006 for the H1-r and L3 cavities, respectively. The measured cavity-frequencies and detector refractive index...... responsivities are in good agreement with simulations, demonstrating that the method provides a background free transducer signal with frequency selective addressing of a specic area of the sensor chip....

  14. Three-dimensional ray tracing for refractive correction of human eye ametropies

    Science.gov (United States)

    Jimenez-Hernandez, J. A.; Diaz-Gonzalez, G.; Trujillo-Romero, F.; Iturbe-Castillo, M. D.; Juarez-Salazar, R.; Santiago-Alvarado, A.

    2016-09-01

    Ametropies of the human eye, are refractive defects hampering the correct imaging on the retina. The most common ways to correct them is by means of spectacles, contact lenses, and modern methods as laser surgery. However, in any case it is very important to identify the ametropia grade for designing the optimum correction action. In the case of laser surgery, it is necessary to define a new shape of the cornea in order to obtain the wanted refractive correction. Therefore, a computational tool to calculate the focal length of the optical system of the eye versus variations on its geometrical parameters is required. Additionally, a clear and understandable visualization of the evaluation process is desirable. In this work, a model of the human eye based on geometrical optics principles is presented. Simulations of light rays coming from a punctual source at six meter from the cornea are shown. We perform a ray-tracing in three dimensions in order to visualize the focusing regions and estimate the power of the optical system. The common parameters of ametropies can be easily modified and analyzed in the simulation by an intuitive graphic user interface.

  15. Prevention of Oral Candidiasis After Free Flap Surgery: Role of 3% Sodium Bicarbonate Saline in Oral Care.

    Science.gov (United States)

    Yang, Yue; Zhang, Fang; Lyu, Xin; Yan, Zhimin; Hua, Hong; Peng, Xin

    2017-03-01

    Relevant reports about oral candidiasis status and prevention measures after free flap surgery for the oral and maxillofacial region are limited. The present study explored oral candidiasis status after free flap surgery and its prevention through a prospective comparative study. One hundred four patients were randomized to a control group (n = 54) and an experimental group (n = 50). Compared with the control group, the experimental group was provided an additional 3% sodium bicarbonate saline solution for oral care after free flap surgery. The incidence of oral candidiasis was evaluated by objective examination (saliva culture and salivary pH measurement) and subjective evaluation (clinical signs of oral candidiasis) at admission and from postoperative days 1 to 14. The salivary pH values of the 2 groups were lower than the normal salivary pH, and postoperative salivary pH values were always lower than the active range of oral lysozymes in the control group. The salivary pH values of the experimental group were higher than those of the control group from postoperative days 6 to 14 (P < .05). The incidence of oral candidiasis was 13.0% in the control group, which was higher than that in the experimental group (2.0%; P < .05). In addition, advanced age, use of a free flap for the simultaneous repair of intraoral and paraoral defects, and a combination of 2 antibiotic types were risk factors for oral candidiasis. Oral candidiasis was common in patients after free flap reconstruction surgery, and the use of 3% sodium bicarbonate saline solution for oral care effectively prevented it. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif

    2016-09-06

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  17. Parsimonious refraction interferometry

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2016-01-01

    We present parsimonious refraction interferometry where a densely populated refraction data set can be obtained from just two shot gathers. The assumptions are that the first arrivals are comprised of head waves and direct waves, and a pair of reciprocal shot gathers is recorded over the line of interest. The refraction traveltimes from these reciprocal shot gathers can be picked and decomposed into O(N2) refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. This enormous increase in the number of virtual traveltime picks and associated rays, compared to the 2N traveltimes from the two reciprocal shot gathers, allows for increased model resolution and better condition numbers in the normal equations. Also, a reciprocal survey is far less time consuming than a standard refraction survey with a dense distribution of sources.

  18. Cataract Surgery From 1918 to the Present and Future-Just Imagine!

    Science.gov (United States)

    Olson, Randall J

    2018-01-01

    To review the history of cataract surgery over the past 100 years, and to offer predictions about new developments that may occur during the next 50 years. Interpretive essay. Review of historical literature and author experiences pertaining to cataract surgery, with commentary and perspective. By this time, cataract surgery has advanced to the point that Kelman's introduction of phacoemulsification and use of intraocular lenses (IOLs), both very controversial when initially introduced, have become state of the art. Outpatient surgery, minimally limited mobility, sutureless incisions, and topical anesthesia also have become key components of standard treatment. The author envisions availability of medications for nuclear sclerosis and presbyopia, expansion of lens surgery for refractive purposes with postsurgical adjustment and unprecedented precision, increased mechanization of lens removal with emphasis on uncomplicated surgery rather than refractive precision, and accommodating IOLs all becoming standard. Acknowledging and appreciating the past contributions of pioneers in cataract surgery is vital to understanding the development of today's clinical care. Clues as to the future do help give us a possible scenario worthy of such conjecture. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Comparison of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients

    Directory of Open Access Journals (Sweden)

    Zhan-Jiang Liu

    2016-01-01

    Full Text Available AIM:To investigate the effects of Bigbag and Rayner620H intraocular lens in cataract surgeries in high myopia patients. METHODS:Seventy-seven patients(128 eyeswere treated by phacoemulsification combined with intraocular lens implantation from January 2014 to March 2015 in our hospital. Thirty-nine patients(65 eyeswere treated with Bigbag intraocular lens, 38 cases(63 eyeswere treated with Rayner620H. The best corrected visual acuity(BCVAdistribution, the actual refractive value, the difference between predictive refractive value and actual refractive value and complications were measured and recorded in the two groups at 1mo after surgeries. RESULTS:The difference between the two groups on BCVA are statistically significant(PWilcoxon rank sum test. The differences between predictive refractive value and actual refractive value of the two groups were statistically significant(PPCONCLUSION:The effect of Bigbag intraocular lens for patients with phacoemulsification and intraocular lens implantation is good, and it can reduce the risk of complications.

  20. Double-layered metal grating for high-performance refractive index sensing.

    Science.gov (United States)

    Li, Guozhen; Shen, Yang; Xiao, Guohui; Jin, Chongjun

    2015-04-06

    The detection of minuscule changes in the local refractive index by localized surface plasmon resonances (LSPRs), carried by metal nanostructures, has been used successfully in applications such as real-time and label-free detection of molecular binding events. However, localized plasmons demonstrate 1-2 orders of magnitude lower figure of merit (FOM) compared with their propagating counterparts. Here, we propose and experimentally demonstrate a high-performance refractive index sensor based on a structure of double-layered metal grating (DMG) with an FOM and FOM* reaching 38 and 40 respectively under normal incidence. Such a high FOM and FOM* arise from a result of a sharp fano resonance, which is caused by the coherent interference between the LSPR from the individual top gold stripes and Wood's anomaly (WA). Moreover, a small conformal decay length of ~68 nm is determined in DMG, indicating that the DMG is a promising candidate for label-free biomedical sensing.

  1. The influence of protein free calf blood extract eye gel on dry eye after pterygium surgery

    Directory of Open Access Journals (Sweden)

    Cai-Ni Ji

    2013-07-01

    Full Text Available AIM: To investigate the influence of protein free calf blood extract eye gel on dry eye after pterygium surgery. METHODS: Thirty six patients(40 eyeswith primary nasal pterygium were enrolled in this study, which were divided into study group and control group randomly, with 20 eyes in each group. All patients received pterygium excision and limbal stem cell autograft surgery and tobramicin dexamethasone eye drops after surgery. Patients of the study group received protein free calf blood extract eye gel while those of the control group received 0.1% sodium hyaluronate eye drops furthermore. Ocular surface disease index(OSDIquestionnaire, tear film break-up time(BUTand Schirmer's Ⅰ test Ⅰ(SⅠtwere carried before and 3 months after surgery to evaluate the dry eye degree of the patients. RESULTS: There was no statistical difference between the age, gender and size of the pterygium of the study and control groups preoperatively. There was no statistical difference between the OSDI(2.33±1.02 vs 2.32±0.93, BUT(8.80±2.48 vs 8.35±2.28seconds and SⅠt(4.30±2.30 vs 4.40±2.44of the two groups preoperatively. There was statistical difference between the OSDI(1.45±0.47 vs 1.81±0.60, BUT(11.20±2.07 vs 9.50±2.40seconds and SⅠt(8.35±3.13 vs 6.35±2.18of the two groups 3 months postoperatively, which was also different from that of the preoperative data correspondingly. CONCLUSION: Protein free calf blood extract eye gel could reduce the dry eye after pterygium surgery.

  2. Microvascular anastomosis using the vascular closure device in free flap reconstructive surgery: A 13-year experience.

    Science.gov (United States)

    Reddy, Chaitan; Pennington, David; Stern, Harvey

    2012-02-01

    The achievement of patency of the microvascular anastomosis in free flap surgery is dependent on a number of factors, central to which is atraumatic handling of the vessel lumen, and intimal apposition. Initial laboratory studies demonstrating the superiority of the non-penetrating vascular closure staple (VCS - Anastoclip ®) were followed by our report in 1999 on a series of free flaps. There is still a paucity of data in the literature on the use of non-penetrating devices for microvascular anastomosis, and our review gives evidence to support the routine use of the VCS in microsurgical free flap surgery. We now report on its successful use over a thirteen year period in 819 free flap reconstructions. Our data indicates the VCS device to be as effective as sutured anastomoses in free tissue transfer surgery. There is also statistically significant data (Barnard's Exact Test) to demonstrate a higher vascular patency rate of the VCS device over sutured anastomoses when sub group analysis is performed. 'Take-back' revision rates were lower amongst flaps that employed VCS use. For arterial anastomoses, this equated to 3/654(0.05%) vs 4/170(2.4%) with hand-sewn anastomoses (p = 0.02). Similarly, for venous anastomoses the 'take-back' revision rate was 7/661(1.1%) vs 8/165(4.8%) with hand-sewn anastomoses (p = 0.003). Furthermore, the major advantage of the VCS is reduction in anastomosis time, from approximately 25 min per anastomosis for sutures to between five and 10 min for staples. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. IOL Implants: Lens Replacement and Cataract Surgery (Intraocular Lenses)

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  4. Postoperative irradiation after reconstructive surgery: comparative study of radiosensitivity between free-skin grafts and skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Kaneda, T.; Oka, T.; Torii, S.; Sakuma, S.

    1984-01-01

    Radiation effects after reconstructive surgery (free-skin grafts and skin flaps) were studied in the rat, and the optimum time for irradiation was determined. The radiosensitivity of both free-skin grafts and skin flaps showed the same trend depending on time of irradiation after operation. The grafts or flaps irradiated in the hypervascular stage showed severe reactions to irradiation, whereas those irradiated in the hypovascular stage showed milder reactions in gross and microangiographic observation. Vascular damage should be given primary consideration when deciding the proper time for irradiation after reconstructive surgery. In general, free-skin grafts showed more severe reactions than skin flaps, especially in the grafts irradiated in the early stage after operation. The experimental results of this study cannot be readily transferred to a clinical setting, but they suggest that postoperative irradiation could be begun 3 to 4 weeks after operation with respect to graft or flap survival, and the results of the clinical cases almost coincide with these experimental results

  5. An aberration corrected photoemission electron microscope at the advanced light source

    International Nuclear Information System (INIS)

    Feng, J.; MacDowell, A.A.; Duarte, R.; Doran, A.; Forest, E.; Kelez, N.; Marcus, M.; Munson, D.; Padmore, H.; Petermann, K.; Raoux, S.; Robin, D.; Scholl, A.; Schlueter, R.; Schmid, P.; Stohr, J.; Wan, W.; Wei, D.H.; Wu, Y.

    2003-01-01

    Design of a new aberration corrected Photoemission electron microscope PEEM3 at the Advanced Light Source is outlined. PEEM3 will be installed on an elliptically polarized undulator beamline and will be used for the study of complex materials at high spatial and spectral resolution. The critical components of PEEM3 are the electron mirror aberration corrector and aberration-free magnetic beam separator. The models to calculate the optical properties of the electron mirror are discussed. The goal of the PEEM3 project is to achieve the highest possible transmission of the system at resolutions comparable to our present PEEM2 system (50 nm) and to enable significantly higher resolution, albeit at the sacrifice of intensity. We have left open the possibility to add an energy filter at a later date, if it becomes necessary driven by scientific need to improve the resolution further

  6. Generation of surface electromagnetic waves in terahertz spectral range by free-electron laser radiation and their refractive index determination

    International Nuclear Information System (INIS)

    Bogomolov, G.D.; Jeong, Uk Young; Zhizhin, G.N.; Nikitin, A.K.; Zavyalov, V.V.; Kazakevich, G.M.; Lee, Byung Cheol

    2005-01-01

    First experiments for observation of surface electromagnetic waves (SEW) in the terahertz spectral range generated on dense aluminum films covering the optical quality glass plates are presented in this paper. Coherent radiation of the new free-electron laser covering the frequency range from 30 to 100cm -1 was used. The interference technique employing SEW propagation in the part of one shoulder of the asymmetric interferometer was applied. From the interference pattern the real part of SEW's effective refractive index ae ' was determined for the two laser emission wavelengths: at λ=150μm-ae ' =1+5x10 -5 , at λ=110μm-ae ' =1+8x10 -4 . High sensitivity of the interference patterns to overlayers made of Ge and Si with thickness of 100nm was demonstrated as well

  7. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  8. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    Science.gov (United States)

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  9. Wave refraction and backward magnon-plasmon polaritons in left-handed antiferromagnet/semiconductor superlattices

    International Nuclear Information System (INIS)

    Tarkhanyan, R.H.; Niarchos, D.G.

    2007-01-01

    Characteristics of the bulk electromagnetic waves in teraHertz frequency region are examined in a left-handed superlattice (SL) which consists of alternating layers of nonmagnetic semiconductor and nonconducting antiferromagnetic materials. General problem on the sign of the refractive index for anisotropic media is considered. It is shown that the phase refraction index is always positive while the group refractive index can be negative when some general conditions are fulfilled. Effective permittivity and permeability tensors of the SL are derived for perpendicular and parallel orientation of the magnetic anisotropy axis with respect to the plane of the layers. Problem of anomalous refraction for transverse electric and transverse magnetic-type polarized waves is examined in such media. Analytical expressions for both the phase and group refractive indices are obtained for various propagated modes. It is shown that, in general, three different types of the refracted waves with different relative orientation of the phase and group velocity vectors are possible in left-handed media. Unusual peculiarities of the backward modes corresponding to the coupled magnon-plasmon polaritons are considered. It is shown, in particular, that the number of the backward modes depends on the free charge carrier's density in semiconductor layers, variation of which allows to create different frequency regions for the wave propagation

  10. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola

    2014-05-02

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  11. Iterative supervirtual refraction interferometry

    KAUST Repository

    Al-Hagan, Ola; Hanafy, Sherif M.; Schuster, Gerard T.

    2014-01-01

    In refraction tomography, the low signal-to-noise ratio (S/N) can be a major obstacle in picking the first-break arrivals at the far-offset receivers. To increase the S/N, we evaluated iterative supervirtual refraction interferometry (ISVI), which is an extension of the supervirtual refraction interferometry method. In this method, supervirtual traces are computed and then iteratively reused to generate supervirtual traces with a higher S/N. Our empirical results with both synthetic and field data revealed that ISVI can significantly boost up the S/N of far-offset traces. The drawback is that using refraction events from more than one refractor can introduce unacceptable artifacts into the final traveltime versus offset curve. This problem can be avoided by careful windowing of refraction events.

  12. Optical traps with geometric aberrations

    International Nuclear Information System (INIS)

    Roichman, Yael; Waldron, Alex; Gardel, Emily; Grier, David G.

    2006-01-01

    We assess the influence of geometric aberrations on the in-plane performance of optical traps by studying the dynamics of trapped colloidal spheres in deliberately distorted holographic optical tweezers. The lateral stiffness of the traps turns out to be insensitive to moderate amounts of coma, astigmatism, and spherical aberration. Moreover holographic aberration correction enables us to compensate inherent shortcomings in the optical train, thereby adaptively improving its performance. We also demonstrate the effects of geometric aberrations on the intensity profiles of optical vortices, whose readily measured deformations suggest a method for rapidly estimating and correcting geometric aberrations in holographic trapping systems

  13. Significance of MR angiography in the diagnosis of aberrant renal arteries as the cause of ureteropelvic junction obstruction in children; Stellenwert der MR-Angiografie in der Diagnostik aberrierender Nierenarterien als Ursache einer Ureterabgangsstenose bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, L.; Sorge, I.; Hirsch, F.W.; Vieweger, A. [Leipzig Univ. (Germany). Dept. of Pediatric Radiology; Goetz, G.; Lehnert, T.; Buehligen, U.; Geyer, C. [Leipzig Univ. (Germany). Dept. of Pediatric Surgery

    2015-01-15

    To determine the importance of MRI with contrast-enhanced MRA for the detection or exclusion of aberrant or obstructing renal arteries in ureteropelvic junction obstruction in children. Key word-based search in RIS database (ureteropelvic junction obstruction/MRI) and retrospective comparison of arterial findings from preoperative contrast-enhanced MRA and intra-operative inspection. From 2007 to 2013, 19 children with ureteropelvic junction obstruction underwent contrast-enhanced MRA. Based on the results of the MRI scan and MAG3 scintigraphy, the children were referred to surgery (Anderson-Hynes-pyeloplasty). An aberrant renal artery was diagnosed with MRI in 14 of 19 children, and intra-operative inspection confirmed 13 of those 14. In the remaining 5 children, no aberrant vessel could be observed in MRI and this was confirmed intra-operatively in 3 of the 5 cases, while in the remaining 2, an aberrant vessel was found. Of the 14 children with aberrant vessels, 12 underwent surgery due to assumed ureteral obstruction, which was confirmed by surgery in 11 cases. In one case, an aberrant artery was found intra-operatively, but obstruction could not be confirmed. In one of the 14 children, the vessel was found in MRI, but its obstructing character was negated via MRA, which was confirmed intra-operatively. In the diagnosis of aberrant and obstructing renal arteries, contrast-enhanced MRA presents 85 % sensitivity and 80 % specificity, with a positive predictive value of 0.8. MRI with contrast-enhanced MRA is suitable to detect aberrant and obstructing renal arteries. An obstructive effect of the aberrant vessel is to be assumed if the vessel has a close relationship to the ureteropelvic junction and if it is linearly stretched.

  14. Understanding refraction contrast using a comparison of absorption and refraction computed tomographic techniques

    Science.gov (United States)

    Wiebe, S.; Rhoades, G.; Wei, Z.; Rosenberg, A.; Belev, G.; Chapman, D.

    2013-05-01

    Refraction x-ray contrast is an imaging modality used primarily in a research setting at synchrotron facilities, which have a biomedical imaging research program. The most common method for exploiting refraction contrast is by using a technique called Diffraction Enhanced Imaging (DEI). The DEI apparatus allows the detection of refraction between two materials and produces a unique ''edge enhanced'' contrast appearance, very different from the traditional absorption x-ray imaging used in clinical radiology. In this paper we aim to explain the features of x-ray refraction contrast as a typical clinical radiologist would understand. Then a discussion regarding what needs to be considered in the interpretation of the refraction image takes place. Finally we present a discussion about the limitations of planar refraction imaging and the potential of DEI Computed Tomography. This is an original work that has not been submitted to any other source for publication. The authors have no commercial interests or conflicts of interest to disclose.

  15. Higher-order aberrations and best-corrected visual acuity in Native American children with a high prevalence of astigmatism.

    Science.gov (United States)

    Miller, Joseph M; Harvey, Erin M; Schwiegerling, Jim

    2015-08-01

    To determine whether higher-order aberrations (HOAs) in children from a highly astigmatic population differ from population norms and whether HOAs are associated with astigmatism and reduced best-corrected visual acuity. Subjects were 218 Tohono O'odham Native American children 5-9 years of age. Noncycloplegic HOA measurements were obtained with a handheld Shack-Hartmann sensor (SHS). Signed (z06s to z14s) and unsigned (z06u to z14u) wavefront aberration Zernike coefficients Z(3,-3) to Z(4,4) were rescaled for a 4 mm diameter pupil and compared to adult population norms. Cycloplegic refraction and best-corrected logMAR letter visual acuity (BCVA) were also measured. Regression analyses assessed the contribution of astigmatism (J0) and HOAs to BCVA. The mean root-mean-square (RMS) HOA of 0.191 ± 0.072 μm was significantly greater than population norms (0.100 ± 0.044 μm). All unsigned HOA coefficients (z06u to z14u) and all signed coefficients except z09s, z10s, and z11s were significantly larger than population norms. Decreased BCVA was associated with astigmatism (J0) and spherical aberration (z12u) but not RMS coma, with the effect of J0 about 4 times as great as z12u. Tohono O'odham children show elevated HOAs compared to population norms. Astigmatism and unsigned spherical aberration are associated with decreased acuity, but the effects of spherical aberration are minimal and not clinically significant. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  16. Dry Eye Epidemiology in Patients before Refractive Operations

    Directory of Open Access Journals (Sweden)

    S. N. Sakhnov

    2018-01-01

    Full Text Available Purpose. To evaluate the prevalence, clinical severity, clinical and pathogenetic variants and etiology of dry eye (DE in patientsbefore refractive surgery. Methods. OSDI testing, lipid interferential test, TBUT, Shirmer-1, -2 tests, compression Norn test in Korbmodification, calculation of xerosis index by Bijsterveld, tear meniscus index evaluation, LIPCOF test, evaluation of epitheliopaty and microerosion by Tseng and lid viper epitheliopaty were performed in 600 myopia (with or without astigmatism patients (234 men, 366 women; 30.1 ± 6.26 years old before refractive surgery. The structure of the DE etiological conditions, was studied both in DE patients and non-DE subjects with calculation of the Pearson xi-square test. To estimate the strength of the connection between the etiological condition and the DE, the normalized value of the Pearson coefficient (C' was used. Results. The dry eye prevalence was 38.83% (of them, 71.76% was mild, 28.83% — moderate, by Brzhesky. Clinical and pathogenetic variants of mild DE included: lipid deficiency (53.29%; lipid-mucin deficiency (26.95%; mucin deficiency (11.38%; state without signs of lipid or mucin deficiency (8.38%. In patients with moderate DE were identified: isolated aqueous deficiency (6.06%; aqueous-lipid deficiency (34.85%; aqueous-mucin deficiency (7.58%; aqueous-lipid-mucin deficiency (51.52%. Statistically significant (р < 0.01 etiological conditions for the disease in patients with diagnosed DE include: contact lenses wearing (C' = 0.349; visual display use (C' = 0.342; the use of medication affecting tear production or tear film stability (C' = 0.41; application of cosmetics (cosmetic pencil or mascara in the intercostal space of the eyelid margin — in the area of the excretory ducts of the meibomian glands (C' = 0.44; meibomian glands dysfunction (C' = 0.782; chronic allergic conjunctivitis (C' = 0.543; the presence of gynecological pathology (C' = 0.413; thyroid

  17. Malignant glaucoma after cataract surgery.

    Science.gov (United States)

    Varma, Devesh K; Belovay, Graham W; Tam, Diamond Y; Ahmed, Iqbal Ike K

    2014-11-01

    To report a series of eyes that developed malignant glaucoma after cataract surgery. Private academic practice, Toronto, Ontario, Canada. Retrospective case series. Eyes that developed malignant glaucoma after cataract surgery were treated with medical therapy. This was followed by laser iridozonulohyaloidotomy, anterior chamber reformation and intraocular lens (IOL) pushback, and finally with surgical iridozonulohyaloidovitrectomy if all other measures were unsuccessful. Refraction, intraocular pressure (IOP), gonioscopy, and anterior chamber depth (ACD) by anterior segment optical coherence tomography were analyzed before treatment and after treatment. The study evaluated 20 eyes of 18 female patients aged 44 to 86 years. Preoperatively, the mean refraction was +3.11 diopters (D) ± 2.89 (SD), the mean axial length was 21.30 ± 1.40 mm, and all eyes had narrow or closed angles. Malignant glaucoma was diagnosed a mean of 5.8 ± 7.1 weeks postoperatively. At diagnosis, the mean refraction was -2.15 ± 2.95 D; the mean ACD, 2.49 ± 0.72 mm; and the mean IOP, 28.3 ± 10.8 mm Hg on a mean of 1.3 ± 1.6 medications. Two eyes responded to cycloplegia, 7 to laser iridozonulohyaloidotomy, and 6 to anterior chamber reformation-IOL pushback; 5 eyes required vitrectomy. Posttreatment, the mean refraction was -0.56 ± 1.07 D; the mean ACD, 3.30 ± 0.50 mm; and the mean IOP, 14.4 ± 4.60 mm Hg on a mean of 1.2 ± 1.4 medications. Cycloplegia was discontinued in 17 eyes. Malignant glaucoma can occur after phacoemulsification and presents with myopic surprise, anterior chamber shallowing and, possibly, elevated IOP. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. "Peak-tracking chip" (PTC) for bulk refractive index sensing and bioarray sensing

    KAUST Repository

    Bougot-Robin, Kristelle; Austin, H. Robert; Benisty, Henri; Hsing, I-Ming; Kodzius, Rimantas; Li, Shunbo; Wen, Weijia; Zhang, Yinghua

    2013-01-01

    Resonant techniques are of wide interest to detect variation of effective refractive index at a chip surface. Both Surface Plasmon Resonance (SPR) and dielectric resonant waveguide (RWGs) can be exploited. Through their design, RWGs allow more flexibility (size of the biomolecule to detect, detection angle…). Using specially designed RWG “Peak-tracking chip”, we propose to use spatial information from a simple monochromatic picture as a new label-free bioarray technique. We discuss robustness, sensitivity, multiplex detection, fluidic integration of the technique and illustrate it through bulk refractive index sensing as well as specific recognition of DNA fragment from gyrase A.

  19. "Peak-tracking chip" (PTC) for bulk refractive index sensing and bioarray sensing

    KAUST Repository

    Bougot-Robin, Kristelle

    2013-10-20

    Resonant techniques are of wide interest to detect variation of effective refractive index at a chip surface. Both Surface Plasmon Resonance (SPR) and dielectric resonant waveguide (RWGs) can be exploited. Through their design, RWGs allow more flexibility (size of the biomolecule to detect, detection angle…). Using specially designed RWG “Peak-tracking chip”, we propose to use spatial information from a simple monochromatic picture as a new label-free bioarray technique. We discuss robustness, sensitivity, multiplex detection, fluidic integration of the technique and illustrate it through bulk refractive index sensing as well as specific recognition of DNA fragment from gyrase A.

  20. Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.

    Science.gov (United States)

    Shraiki, Mario; Arba-Mosquera, Samuel

    2011-06-01

    To evaluate ablation algorithms and temperature changes in laser refractive surgery. The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.

  1. Mask-induced aberration in EUV lithography

    Science.gov (United States)

    Nakajima, Yumi; Sato, Takashi; Inanami, Ryoichi; Nakasugi, Tetsuro; Higashiki, Tatsuhiko

    2009-04-01

    We estimated aberrations using Zernike sensitivity analysis. We found the difference of the tolerated aberration with line direction for illumination. The tolerated aberration of perpendicular line for illumination is much smaller than that of parallel line. We consider this difference to be attributable to the mask 3D effect. We call it mask-induced aberration. In the case of the perpendicular line for illumination, there was a difference in CD between right line and left line without aberration. In this report, we discuss the possibility of pattern formation in NA 0.25 generation EUV lithography tool. In perpendicular pattern for EUV light, the dominant part of aberration is mask-induced aberration. In EUV lithography, pattern correction based on the mask topography effect will be more important.

  2. Photorefractive keratectomy after cataract surgery in uncommon cases: long-term results

    Directory of Open Access Journals (Sweden)

    Anna Maria Roszkowska

    2018-04-01

    Full Text Available AIM: To evaluate the efficacy and safety of the excimer laser correction of the residual refractive errors after cataract extraction with intraocular lens (IOL implantation in uncommon cases. METHODS: Totally 24 patients with high residual refractive error after cataract surgery with IOL implantation were examined. Twenty-two patients had a history of phacoemulsification and IOL implantation, and two had extra-capsular cataract extraction with IOL implantation. Detailed examination of preoperative medical records was done to explain the origin of the post-cataract refractive errors. All patients underwent photorefractire keratectomy (PRK enhancement. The mean outcome measures were refraction, uncorretted visual acuity (UCVA, best corrected visual acuity (BCVA and corneal transparency and follow up ranged from 1 to 8y. RESULTS: The principal causes of residual ametropia was inexact IOL calculation in abnormal eyes with high myopia and congenital lens abnormalities, followed by corneal astigmatism both suture induced and preexisting. After cataract surgery and before the laser enhancement the mean spherical equivalent (SE was -0.56±3 D ranging from -4.62 to +2.25 D in high myopic patients, instead it was -1±1.73 D ranging from -3.25 to +3.75 D in the astigmatic eyes, with a mean cylinder of -3.75±0 ranging from -3 to +5.50 D. After laser refractive surgery the mean SE was 0.1±0.73, ranging from -0.50 to +1.50 in the myopic group, and it was -0.50±0.57 ranging from -1.25 to +0.50 in astigmatic patients, with a mean cylinder of -0.25±0.75. In myopic patients the mean UCVA and BCVA were 0.038±0.072 logMAR and 0.018±0.04 respectively, both ranging from 0.10 to 0.0. In astigmatic patients, the mean UCVA and BCVA were 0.213±0.132 and 0.00±0.0 respectively, UCVA ranging from 0.50 to 0.22 and BCVA was 0.00. All patients presented normal corneal transparency. No ocular hypertension was detected and no corneal haze was observed. All registered

  3. Surgical treatment of massive bleeding of a right aberrant subclavian artery after oesophageal stent removal

    Directory of Open Access Journals (Sweden)

    Michael Raum

    2018-06-01

    Full Text Available We report a case of a 9-year-old female who required surgical treatment and resuscitation after severe transoesophageal bleeding of a right aberrant subclavian artery (RASA. Bleeding of this RASA was caused by a mechanical irritation due to an oesophageal stent. The stent was placed weeks before to dilate the oesophagus after accidental ingestion of a caustic agent. Although conservative management of benign oesophageal stenosis in children is highly recommended, there are still some major complications to be considered. To avoid erosion of aberrant subclavian artery vascular rings and slings, as described in several case reports, these vessels should be excluded by computed tomography (CT or magnetic resonance imaging (MRI scans before placement of oesophageal stents. This case suggests that management of caustic ingestion in children is still a major challenge in paediatric surgical departments. Keywords: Paediatric surgery, Chemical Burn, Oesophageal stenosis, Oesophageal stenting, Vascular abnormalities, Right aberrant subclavian artery

  4. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif; Schuster, Gerard T.

    2017-01-01

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves

  5. A Comparison of the American Society of Cataract and Refractive Surgery post-myopic LASIK/PRK Intraocular Lens (IOL calculator and the Ocular MD IOL calculator

    Directory of Open Access Journals (Sweden)

    Hsu M

    2011-09-01

    Full Text Available David L DeMill1, Majid Moshirfar1, Marcus C Neuffer1, Maylon Hsu1, Shameema Sikder21John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 2Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USABackground: To compare the average values of the American Society of Cataract and Refractive Surgery (ASCRS and Ocular MD intraocular lens (IOL calculators to assess their accuracy in predicting IOL power in patients with prior laser-in-situ keratomileusis (LASIK or photorefractive keratectomy.Methods: In this retrospective study, data from 21 eyes with previous LASIK or photorefractive keratectomy for myopia and subsequent cataract surgery was used in an IOL calculator comparison. The predicted IOL powers of the Ocular MD SRK/T, Ocular MD Haigis, and ASCRS averages were compared. The Ocular MD average (composed of an average of Ocular MD SRK/T and Ocular MD Haigis and the all calculator average (composed of an average of Ocular MD SRK/T, Ocular MD Haigis, and ASCRS were also compared. Primary outcome measures were mean arithmetic and absolute IOL prediction error, variance in mean arithmetic IOL prediction error, and the percentage of eyes within ±0.50 and ±1.00 D.Results: The Ocular MD SRK/T and Ocular MD Haigis averages produced mean arithmetic IOL prediction errors of 0.57 and –0.61 diopters (D, respectively, which were significantly larger than errors from the ASCRS, Ocular MD, and all calculator averages (0.11, –0.02, and 0.02 D, respectively, all P < 0.05. There was no statistically significant difference between the methods in absolute IOL prediction error, variance, or the percentage of eyes with outcomes within ±0.50 and ±1.00 D.Conclusion: The ASCRS average was more accurate in predicting IOL power than the Ocular MD SRK/T and Ocular MD Haigis averages alone. Our methods using combinations of these averages which, when compared with the individual averages, showed a trend of decreased mean arithmetic IOL

  6. Dry Eye Disease following Refractive Surgery: A 12-Month Follow-Up of SMILE versus FS-LASIK in High Myopia

    Directory of Open Access Journals (Sweden)

    Bingjie Wang

    2015-01-01

    Full Text Available Purpose. To compare dry eye disease following SMILE versus FS-LASIK. Design. Prospective, nonrandomised, observational study. Patients. 90 patients undergoing refractive surgery for myopia were included. 47 eyes underwent SMILE and 43 eyes underwent FS-LASIK. Methods. Evaluation of dry eye disease was conducted preoperatively and at 1, 3, 6, and 12 months postoperatively, using the Salisbury Eye Evaluation Questionnaire (SEEQ and TBUT. Results. TBUT reduced following SMILE at 1 and 3 months (p<0.001 and at 1, 3, and 6 months following FS-LASIK (p<0.001. TBUT was greater following SMILE than FS-LASIK at 3, 6, and 12 months (p<0.001, p<0.001, and p=0.009, resp.. SEEQ scores increased (greater symptoms following SMILE at 1 month (p<0.001 and 3 months (p=0.003 and at 1, 3, and 6 months following FS-LASIK (p<0.001. SMILE produced lower SEEQ scores (fewer symptoms than FS-LASIK at 1, 3, and 6 months (p<0.001. Conclusion. SMILE produces less dry eye disease than FS-LASIK at 6 months postoperatively but demonstrates similar degrees of dry eye disease at 12 months.

  7. Incidence and Outcomes of Optical Zone Enlargement and Recentration After Previous Myopic LASIK by Topography-Guided Custom Ablation.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara

    2018-02-01

    To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after

  8. Lower- and higher-order aberrations predicted by an optomechanical model of arcuate keratotomy for astigmatism.

    Science.gov (United States)

    Navarro, Rafael; Palos, Fernando; Lanchares, Elena; Calvo, Begoña; Cristóbal, José A

    2009-01-01

    To develop a realistic model of the optomechanical behavior of the cornea after curved relaxing incisions to simulate the induced astigmatic change and predict the optical aberrations produced by the incisions. ICMA Consejo Superior de Investigaciones Científicas and Universidad de Zaragoza, Zaragoza, Spain. A 3-dimensional finite element model of the anterior hemisphere of the ocular surface was used. The corneal tissue was modeled as a quasi-incompressible, anisotropic hyperelastic constitutive behavior strongly dependent on the physiological collagen fibril distribution. Similar behaviors were assigned to the limbus and sclera. With this model, some corneal incisions were computer simulated after the Lindstrom nomogram. The resulting geometry of the biomechanical simulation was analyzed in the optical zone, and finite ray tracing was performed to compute refractive power and higher-order aberrations (HOAs). The finite-element simulation provided new geometry of the corneal surfaces, from which elevation topographies were obtained. The surgically induced astigmatism (SIA) of the simulated incisions according to the Lindstrom nomogram was computed by finite ray tracing. However, paraxial computations would yield slightly different results (undercorrection of astigmatism). In addition, arcuate incisions would induce significant amounts of HOAs. Finite-element models, together with finite ray-tracing computations, yielded realistic simulations of the biomechanical and optical changes induced by relaxing incisions. The model reproduced the SIA indicated by the Lindstrom nomogram for the simulated incisions and predicted a significant increase in optical aberrations induced by arcuate keratotomy.

  9. Refractive index sensor based on total scattering of plasmonic nanotube

    Science.gov (United States)

    Yao, Kaiqiang; Zeng, Qingbing; Hu, Zengrong; Zhan, Yaohui

    2018-03-01

    Plasmonic nanostructures can couple free space light into anultrafine space; therefore,they are employed extensively in the refractive index sensors to minimize the device size or further improve the detection sensitivity. In this work, the optical response of the plasmonic nanotube are investigated comprehensively by using full wave finite element method. With a subwavelength scale, the silver nanotube have prominent scattering peaks in the visible range, which is very suitable for observing through the dark field microscope. The geometric dependence of the scattering spectra and the sensing performance are evaluated carefully. Results show that the scattering peaks are in linear relationship to the circumstance refractive index and a sensitivity of 337 nm/RIUcan be achieved easily by such a plasmonicnanotube with an optimized size.

  10. Crystalline lens power and refractive error.

    Science.gov (United States)

    Iribarren, Rafael; Morgan, Ian G; Nangia, Vinay; Jonas, Jost B

    2012-02-01

    To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal refractive power, anterior chamber depth, lens thickness, and axial length according to Bennett's formula. The study included 1885 subjects. Mean refractive lens power was 25.5 ± 3.0 D (range, 13.9-36.6). After adjustment for age and sex, the standardized correlation coefficients (β) of the association with the ocular refractive error were highest for crystalline lens power (β = -0.41; P lens opacity grade (β = -0.42; P lens power (β = -0.95), lower corneal refractive power (β = -0.76), higher lens thickness (β = 0.30), deeper anterior chamber (β = 0.28), and less marked nuclear lens opacity (β = -0.05). Lens thickness was significantly lower in eyes with greater nuclear opacity. Variations in refractive error in adults aged 50+ years were mostly influenced by variations in axial length and in crystalline lens refractive power, followed by variations in corneal refractive power, and, to a minor degree, by variations in lens thickness and anterior chamber depth.

  11. Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2012-06-01

    Full Text Available PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients had an uncorrected visual acuity of 20/20 or better in the myopic and hyperopic groups, respectively. The safety and efficacy indexes were 1.05 and 0.88 for the myopic and 1.01 and 0.86 for the hyperopic groups at distance vision. Within the myopic group, 20 eyes remained unchanged after the surgery, and 3 gained >2 lines of best corrected visual acuity. For the hyperopic group, 2 eyes lost 2 lines of best corrected visual acuity, 21 did not change, and 3 eyes gained 2 lines. At near vision, the safety and efficacy indexes were 1.23 and 1.17 for the myopic and 1.16 and 1.13 for the hyperopic groups. Best corrected near visual acuity improved after surgery in both groups (from 0.10 logMAR to 0.01 logMAR in the myopic group, and from 0.10 logMAR to 0.04 logMAR in the hyperopic group. CONCLUSIONS: The ReSTOR® SN6AD3 intraocular lens in refractive lens exchange demonstrated good safety, efficacy, and predictability in correcting high ametropia and presbyopia.

  12. Estudo refracional em crianças pseudofácicas Refraction study on pseudophakic children

    Directory of Open Access Journals (Sweden)

    Gerson López Moreno

    2005-06-01

    Full Text Available OBJETIVO: Verificar as alterações refratométricas em olhos de crianças submetidas à cirurgia de catarata com implante de lente intra-ocular (LIO e pesquisar a previsão da biometria nesses casos. MÉTODOS: Foram estudados 33 olhos com medição prévia da acuidade visual com indicação cirúrgica de catarata com implante de lente intra-ocular no Ambulatório de Catarata Congênita da Escola Paulista de Medicina - Universidade Federal de São Paulo (UNIFESP-EPM, desde janeiro de 1998 até dezembro de 2000. No pós-operatório foi realizada a refração, prescritos os óculos com o adequado tratamento para estimulação visual da criança e a medida da acuidade visual final com a correção. Foram analisadas: refrações finais, a acurácia da biometria e os possíveis fatores de erros. RESULTADOS: Foram realizadas 33 cirurgias em 29 crianças. O seguimento teve média de 10,15 meses com variação de 2 até 34 ±8,18 meses. Em 43% dos casos obteve-se visão igual ou maior que 20/50. Quarenta e seis por cento dos pacientes apresentaram refração final entre +1,00 e -1,00 dioptrias esféricas. CONCLUSÃO: O tratamento da catarata congênita mediante implante de lente intra-ocular continua controverso, sendo que os resultados a longo prazo não são conhecidos. Número grande de pacientes foram operados tardiamente evoluindo com ambliopia e baixa acuidade visual mesmo após o tratamento devido a grande dificuldade de acesso ao tratamento adequado e precoce. Apesar da refração residual os pacientes obtiveram boa acuidade visual. Em 21% dos casos que permaneceram com alteração refratométrica com hipermetropia ainda terão aumento no seu diâmetro axial e conseqüentemente miopização com redução de sua refração.PURPOSE: To verify the refractive alterations in eyes of children submitted to surgery with implant of intraocular lens (IOL and to investigate prediction of biometry in these cases. METHODS: Thirty-three eyes were studied with

  13. Personalized pseudophakic model for refractive assessment.

    Science.gov (United States)

    Ribeiro, Filomena J; Castanheira-Dinis, António; Dias, João M

    2012-01-01

    To test a pseudophakic eye model that allows for intraocular lens power (IOL) calculation, both in normal eyes and in extreme conditions, such as post-LASIK. The model's efficacy was tested in 54 participants (104 eyes) who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corneal topography. MODELLING: The Liou-Brennan eye model was used as a starting point, and biometric values were replaced by individual measurements. Detailed corneal surface data were obtained from topography (Orbscan®) and a grid of elevation values was used to define corneal surfaces in an optical ray-tracing software (Zemax®). To determine IOL power, optimization criteria based on values of the modulation transfer function (MTF) weighted according to contrast sensitivity function (CSF), were applied. Pre-operative refractive assessment calculated by our eye model correlated very strongly with SRK/T (r = 0.959, p0.05). Comparison of post-operative refractive assessment obtained using our eye model with the average of currently used formulas showed a strong correlation (r = 0.778, p0.05). Results suggest that personalized pseudophakic eye models and ray-tracing allow for the use of the same methodology, regardless of previous LASIK, independent of population averages and commonly used regression correction factors, which represents a clinical advantage.

  14. On- and off-eye spherical aberration of soft contact lenses and consequent changes of effective lens power.

    Science.gov (United States)

    Dietze, Holger H; Cox, Michael J

    2003-02-01

    Soft contact lenses produce a significant level of spherical aberration affecting their power on-eye. A simple model assuming that a thin soft contact lens aligns to the cornea predicts that these effects are similar on-eye and off-eye. The wavefront aberration for 17 eyes and 33 soft contact lenses on-eye was measured with a Shack-Hartmann wavefront sensor. The Zernike coefficients describing the on-eye spherical aberration of the soft contact lens were compared with off-eye ray-tracing results. Paraxial and effective lens power changes were determined. The model predicts the on-eye spherical aberration of soft contact lenses closely. The resulting power change for a +/- 7.00 D spherical soft contact lens is +/- 0.5 D for a 6-mm pupil diameter and +/- 0.1 D for a 3-mm pupil diameter. Power change is negligible for soft contact lenses corrected for off-eye spherical aberration. For thin soft contact lenses, the level of spherical aberration and the consequent power change is similar on-eye and off-eye. Soft contact lenses corrected for spherical aberration in air will be expected to be aberration-free on-eye and produce only negligibly small power changes. For soft contact lenses without aberration correction, for higher levels of ametropia and large pupils, the soft contact lens power should be determined with trial lenses with their power and p value similar to the prescribed lens. The benefit of soft contact lenses corrected for spherical aberration depends on the level of ocular spherical aberration.

  15. Induced Higher-order aberrations after Laser In Situ Keratomileusis (LASIK) Performed with Wavefront-Guided IntraLase Femtosecond Laser in moderate to high Astigmatism.

    Science.gov (United States)

    Al-Zeraid, Ferial M; Osuagwu, Uchechukwu L

    2016-03-22

    Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, -3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser-enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61% of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from -0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0

  16. [Femtosecond laser in cataract surgery. A critical appraisal].

    Science.gov (United States)

    Menapace, R M; Dick, H B

    2014-01-01

    The use of femtosecond lasers (FSL) is increasingly spreading in cataract surgery. Potential advantages over standard manual cataract surgery are the superior precision of corneal incisions and capsular openings as well as the reduction of ultrasound energy for lens nucleus work-up. Exact positioning and dimensioning of the anterior capsular opening should help reduce decentration and tilt of the intraocular lens (IOL) optics and thus achieve better target refraction. Together with the possibility to correct low-grade corneal astigmatism by precise arcuate incision, FSL technology is expected to convert cataract surgery from a purely curative into a refractive procedure. Apart from own experiences this review article critically analyses the pertinent literature published so far as well as congress presentations and personal reports of other FSL surgeons. The advantages and disadvantages are scrutinized with regard to their impact on the surgical and refractive results and compared with those experienced by the authors with manual cataract surgery over several decades. Economic and healthcare political aspects are also addressed. The use of FSL surgery improves the precision and reproducibility of corneal incisions and the capsular opening and reduces the amount of ultrasound energy required for lens nucleus work-up. However, the clinical benefits must be put into perspective due to the subsequent surgical manipulation of the incisions (during lens emulsification, aspiration and IOL injection), the lacking possibility to visualize the crystalline lens equator as the reference for correct capsulotomy centration and the relativity of ultrasound energy consumption on the corneal endothelial trauma. This is of particular relevance against the background of the significantly higher costs. Conversely, tears of the anterior capsule edge which, apart from interfering with correct IOL positioning, may entail serious complications presently occur more frequently with all FSL

  17. Incidence and types of complications after ablative oral cancer surgery with primary microvascular free flap reconstruction

    NARCIS (Netherlands)

    Lodders, J.N.; Parmar, S.; Stienen, N.-L.M.; Martin, T.J.; Karagozoglu, K.H.; Heymans, M.W.; Nandra, B.; Forouzanfar, T.

    2015-01-01

    Background: The aims of the study were 1) to evaluate the incidence and types of postoperative complications after ablative oral cancer surgery with primary free flap reconstruction and 2) identify prognostic variables for postoperative complications. Material and Methods: Desired data was retrieved

  18. Incidence and types of complications after ablative oral cancer surgery with primary microvascular free flap reconstruction

    NARCIS (Netherlands)

    Lodders, J.N.; Parmar, S.; Stienen, N.L.M.; Martin, T.J.; Karagozoglu, K.H.; Heymans, M.W.; Nandra, B.; Forouzanfar, T.

    2015-01-01

    BACKGROUND: The aims of the study were 1) to evaluate the incidence and types of postoperative complications after ablative oral cancer surgery with primary free flap reconstruction and 2) identify prognostic variables for postoperative complications. MATERIAL AND METHODS: Desired data was retrieved

  19. Theoretical and experimental study of ions focusing systems in order to improve the ions beam brightness by suppressing aberration causes; Etude theorique et experimentale de la focalisation des ions afin d'ameliorer la brillance du faisceau ionique par la suppression des causes d'aberration

    Energy Technology Data Exchange (ETDEWEB)

    Faure, J

    1966-07-01

    It is shown that a beam brightness can be improved by an order of magnitude when the sources of aberrations are suppressed in the anode region source, as well as in the extraction region and in the electrostatic focusing system. A calculation was first set up to determine a simple focusing system. The aberration ratio due to this focusing system is smaller than 10 to 15 per cent. The experimental study was developed by using an ion source and its extraction system capable of producing an aberration free beam at an energy of 20 keV and an accelerating unit up to 190 keV that confirms that the qualities of a 35 mA beam produced by the said ion source are not spoiled when the beam goes through the focusing and accelerating system that was designed to be aberration free. (author) [French] Dans ce travail, on s'attache a demontrer que la brillance d'un faisceau peut etre amelioree d'un ordre de grandeur lorsque l'on supprime les causes d'aberration aussi bien a la sortie de la source, dans la zone d'extraction, que dans le systeme de focalisation electrostatique. Un calcul est, tout d'abord, mis au point pour determiner un systeme de focalisation simple. Cette focalisation n'entraine pas un taux d'aberrations superieur a 10 ou 15 pour cent. Puis l'etude experimentale conduit: a) a la realisation d'une source et de son systeme d'extraction fournissant un faisceau sans aberration a une energie de 20 keV. b) et a l'elaboration d'un petit accelerateur a 190 keV qui verifie que les proprietes d'un faisceau de 35 mA issu de la source ne sont pas affectees par la traversee des systemes focalisateur et accelerateur lorsque ceux-ci n'apportent pas d'aberration. (auteur)

  20. Comparison of single-step reverse transepithelial all-surface laser ablation (ASLA) to alcohol-assisted photorefractive keratectomy.

    Science.gov (United States)

    Aslanides, Ioannis M; Padroni, Sara; Arba Mosquera, Samuel; Ioannides, Antonis; Mukherjee, Achyut

    2012-01-01

    To evaluate postoperative pain, corneal epithelial healing, development of corneal haze, refractive outcomes, and corneal aberrations in a novel one-step, modified transepithelial photorefractive keratectomy (PRK), termed All-surface laser ablation (ASLA), compared to conventional, alcohol-assisted PRK. Sixty eyes of 30 myopic patients were prospectively recruited to a randomized fellow eye study. Patients underwent conventional alcohol-assisted PRK in one eye (control group) and ASLA-modified transepithelial PRK in the other (30 eyes in each treatment arm). Primary endpoints were postoperative pain and haze scores at 1 day, 3 days, 1 week, and 1, 3, 6, and 12 months. Secondary endpoints included visual acuity at 1, 3, 6, and 12 months, corneal aberrations at 3, 6, and 12 months, and early and late onset haze. Refractive predictability, safety, and efficacy of the two methods were considered. The average age of the cohort was 29 years (standard deviation [SD]: 9; range: 18-46), and the average spherical equivalent refractive error was -4.18 diopters (SD: 1.9). At 3 days after surgery, the average pain score was 64% lower in the ASLA group (P < 0.0005). At this point, 96% of ASLA eyes had no epithelial defect, whereas 43% in the alcohol-assisted group did not achieve complete epithelial healing, and required replacement of bandage contact lens. The haze level was consistently lower in the ASLA group at all time points from 1 to 6 months. This study shows that the ASLA technique may have a future role in refractive surgery, due to the fact that it offers faster epithelial healing, lower pain scores, and significantly less haze formation.

  1. Metal-Free Poly-Cycloaddition of Activated Azide and Alkynes toward Multifunctional Polytriazoles: Aggregation-Induced Emission, Explosive Detection, Fluorescent Patterning, and Light Refraction.

    Science.gov (United States)

    Wu, Yongwei; He, Benzhao; Quan, Changyun; Zheng, Chao; Deng, Haiqin; Hu, Rongrong; Zhao, Zujin; Huang, Fei; Qin, Anjun; Tang, Ben Zhong

    2017-09-01

    The metal-free click polymerization (MFCP) of activated alkynes and azides or activated azide and alkynes have been developed into powerful techniques for the construction of polytriazoles without the obsession of metallic catalyst residues problem. However, the MFCP of activated azides and alkynes is rarely applied in preparation of functional polytriazoles. In this paper, soluble multifunctional polytriazoles (PIa and PIb) with high weight-average molecular weights (M w up to 32 000) are prepared via the developed metal-free poly-cycloaddition of activated azide and alkynes in high yields (up to 90%). The resultant PIa and PIb are thermally stable, and show aggregation-induced emission characteristics, enabling their aggregates to detect explosives with superamplification effect. Moreover, thanks to their containing aromatic rings and polar moieties, PIa and PIb exhibit high refractive indices. In addition, they can also be cross-linked upon UV irradiation to generate 2D fluorescent patterning due to their remaining azide groups and containing ester groups. Thus, these multifunctional polytriazoles are potentially applicable in the optoelectronic and sensing fields. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Refraction in the lower troposphere: Higher order image distortion effects due to refractive profile curvature

    Science.gov (United States)

    Short, Daniel J.

    There are many applications that rely on the propagation of light through the atmosphere - all of which are subject to atmospheric conditions. While there are obvious processes such as scattering due to particulates like clouds and dust that affect the received intensity of the radiation, the clear atmosphere can also cause significant effects. Refraction is a clear air effect that can cause a variety of phenomena such as apparent relocation, stretching and compression of objects when viewed through the atmosphere. Recently, there has been significant interest in studying the refractive effects for low angle paths within the troposphere, and in particular, near-horizontal paths in the Earth's boundary layer, which is adjacent to the ground. Refractive effects in this case become problematic for many terrestrial optical applications. For example, the pointing of a free space optical communication or a remote sensing system can suffer wandering effects, high-resolution imagery can present distorted and/or dislocated targets, optical tracking of targets can be inaccurate, and optical geodetic surveying accuracy is also very sensitive to the effects of refraction. The work in this dissertation was inspired by data from a time-lapse camera system that collects images of distant targets over a near-horizontal path along the ground. This system was used previously to study apparent diurnal image displacement and this dissertation extends that work by exploring the higher order effects that result from curvature in the vertical refractive index profile of the atmosphere. There are surprisingly few experiments involving atmospheric refractive effects that carefully correlate field data to analytical expressions and other factors such as meteorological data. In working with the time-lapse data, which is comprised of sequences of hundreds or thousands of images collected over durations of weeks or months, it is important to develop straightforward analysis techniques that can

  3. Alterações motoras após cirurgia refrativa no paciente estrábico Motor disturbances after refractive surgery in patients with strabismus

    Directory of Open Access Journals (Sweden)

    Rosana Nogueira Pires da Cunha

    2004-06-01

    second group. RESULTS: All patients of the first group required strabismus surgery in order to control symptoms of double vision or to correct the ocular deviation. The majority of the patients of the second group had worsening of their sensorial condition and some also presented worsening of their motor conditions. Half of the patients of the second group showed some relief of astenopia when eyeglasses for near were used. Those with accomodative esotropia did not have any or had less symptoms after the laser procedure and the follow-up showed more stable clinical feature. CONCLUSIONS: Refractive surgeons must select their patients and avoid underestimating some conditions that might compromise fusion capability after laser. We recommend motor and sensorial evaluation as part of their preoperative work up for candidates for refractive surgery.

  4. Modal study of refractive effects on x-ray laser coherence

    International Nuclear Information System (INIS)

    Amendt, P.; London, R.A.; Strauss, M.

    1991-01-01

    The role of smoothly varying transverse gain and refraction profiles on x-ray laser intensity and coherence is analyzed by modally expanding the electric field within the paraxial approximation. Comparison with a square transverse profile reveals that smooth-edged profiles lead to: (1) a greatly reduced number of guided modes, (2) the continued cancellation of local intensity from a loosely guided mode by resonant free modes, (3) and the absence of extraneous (or anomalous) free mode resonances. These generic spectral properties should enable a considerable simplification in analyzing and optimizing the coherence properties of laboratory soft x-ray lasers. 6 refs., 3 figs

  5. Influence of refraction index strength on the light propagation in dielectrics material with periodic refraction index

    International Nuclear Information System (INIS)

    Hidayat, Arif; Latifah, Eny; Kurniati, Diana; Wisodo, Hari

    2016-01-01

    This study investigated the influence of refraction index strength on the light propagation in refraction index-varied dielectric material. This dielectric material served as photonic lattice. The behavior of light propagation influenced by variation of refraction index in photonic lattice was investigated. Modes of the guiding light were determined numerically using squared-operator iteration method. It was found that the greater the strength of refraction index, the smaller the guiding modes.

  6. Design and analysis of beam separator magnets for third generation aberration compensated PEEMs

    International Nuclear Information System (INIS)

    Wu, Y.K.; Robin, D.S.; Forest, E.; Schlueter, R.; Anders, S.; Feng, J.; Padmore, H.; Wei, D.H.

    2004-01-01

    A state of the art X-ray photoemission electron microscope (PEEM2) is operational at the Advanced Light Source at a resolution of typically 50 nm for a range of chemical and magnetic surface studies. A new microscope, PEEM3, is under development with an aim of achieving a resolution of 5 nm and more than an order of magnitude increase in transmission at the nominal resolution of PEEM2. The resolution and flux improvement is realized by providing geometric and chromatic aberration compensations in the system using an electron mirror and a beam separator magnet. The nearly aberration-free design of the beam separator is critical to the performance of third generation PEEMs. In this paper, we present the optics design model, optimal operation parameters, analyses of aberration impact, as well as the mechanical alignment tolerance for PEEM3 separator prototypes. In particular, we emphasize the importance of a new semi-analytical approach to design complex charged particle optics using the truncated power series algebra. Because of its ability to compute high-order aberrations, this approach allows systematic and comprehensive analyses of any charged particle optics systems with analytical electric and magnetic fields

  7. Studies on protective effects of superoxide dismutase on radiation induced-chromosomal aberrations

    International Nuclear Information System (INIS)

    Zheng Siying; Jiang Jiagui; Lin Xingcheng

    1987-09-01

    This study demonstrates that radiation induced-chromosomal aberrations are not only due to the direct effect of radiation h it , but the indirect effect of free radical as well. Therefore, chromosome damage induced by radiation may be reduced by adding exogenous SOD into the radiation exposed lymphocyte culture to eliminate the superoxide free radical which damages DNA. On the other hand, however, the radiosensitivity of lymphocytes can be raised by adding SOD inhibitor (DDC) into the lymphocyte culture, which makes radiation induced-chromosomal damages more severely

  8. Sensitivity of photonic crystal fiber grating sensors: biosensing, refractive index, strain, and temperature sensing

    DEFF Research Database (Denmark)

    Rindorf, Lars Henning; Bang, Ole

    2008-01-01

    We study the sensitivity of fiber grating sensors in the applications of strain, temperature, internal label-free biosensing, and internal refractive index sensing. New analytical expressions for the sensitivities, valid for photonic crystal fibers are rigorously derived. These are generally vali...

  9. Non-random intrachromosomal distribution of radiation-induced chromatid aberrations in Vicia faba. [Aberration clustering

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, I; Rieger, R [Akademie der Wissenschaften der DDR, Gatersleben. Zentralinst. fuer Genetik und Kulturpflanzenforschung

    1976-04-01

    A reconstructed karyotype of Vicia faba, with all chromosomes individually distinguishable, was treated with X-rays, fast neutrons, (/sup 3/H) uridine (/sup 3/HU). The distribution within metaphase chromosomes of induced chromatid aberrations was non-random for all agents used. Aberration clustering, in part agent specific, occurred in chromosome segments containing heterochromatin as defined by the presence of G bands. The pattern of aberration clustering found after treatment with /sup 3/HU did not allow the recognition of chromosome regions active in transcription during treatment. Furthermore, it was impossible to obtain unambiguous indications of the presence of AT- and GC-base clusters from the patterns of /sup 3/HT- and /sup 3/HC-induced chromatid aberrations, respectively. Possible reasons underlying these observations are discussed.

  10. Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-up.

    Science.gov (United States)

    Aizawa, Daisuke; Shimizu, Kimiya; Komatsu, Mari; Ito, Misae; Suzuki, Masanobu; Ohno, Koji; Uozato, Hiroshi

    2003-08-01

    To evaluate the clinical outcomes 6 months after wavefront-guided laser in situ keratomileusis (LASIK) for myopia in Japan. Department of Ophthalmology, Sanno Hospital, Tokyo, Japan. This prospective study comprised 22 eyes of 12 patients treated with wavefront-guided LASIK who were available for evaluation at 6 months. The mean patient age was 31.2 years +/- 8.4 (SD) (range 23 to 50 years), and the mean preoperative spherical equivalent refraction was -7.30 +/- 2.72 diopters (D) (range -2.75 to -11.88 D). In all cases, preoperative wavefront analysis was performed with a Hartmann-Shack aberrometer and the Technolas 217z flying-spot excimer laser system (Bausch & Lomb) was used with 1.0 mm and 2.0 mm spot sizes and an active eye tracker with a 120 Hz tracking rate. The clinical outcomes of wavefront-guided LASIK were evaluated in terms of safety, efficacy, predictability, stability, complications, and preoperative and postoperative aberrations. At 6 months, 10 eyes had no change in best spectacle-correct visual acuity and 10 gained 1 or more lines. The safety index was 1.11 and the efficacy index, 0.82. Slight undercorrections were observed in highly myopic eyes. In all eyes, the postoperative refraction tended slightly toward myopia for 3 months and stabilized after that. No complication such as epithelial ingrowth, diffuse lamellar keratitis, or infection was observed. Comparison of the preoperative and postoperative aberrations showed that 2nd-order aberrations decreased and higher-order aberrations increased. In the 3rd order, aberrations increased in the high-myopia group (-6.0 D or worse) and decreased in the low to moderate-myopia group (better than -6.0 D). Wavefront-guided LASIK was a good option for refractive surgery, although a longer follow-up in a larger study is required.

  11. Use of M-FISH analysis of α-particle-induced chromosome aberrations for the assessment of chromosomal breakpoint distribution and complex aberration formation

    International Nuclear Information System (INIS)

    Anderson, R.M.; Sumption, N.D.; Papworth, D.G.; Goodhead, D.T.

    2003-01-01

    Double strand breaks (dsb) of varying complexity are an important class of damage induced after exposure to ionising radiation and are considered to be the critical lesion for the formation of radiation-induced chromosome aberrations. Assuming the basic principles of the 'Breakage and Reunion' theory, dsb represent 'breakage' and aberrations are produced from the illegitimate repair (reunion) of the resulting dsb free-'ends'. Numerous questions relate to this process, in particular, (1) do chromosomal breakpoint 'hot-spots' that represent sensitive sites for breakage and/or regions of preferential repair/mis-repair, exist? (2) Considering that individual chromosomes and chromosome regions occupy discrete territories in the interphase nucleus, could rearrangements between specific chromosomes reflect domain organisation at the time of damage? (3) Assuming the topological constraints imposed on chromatin are not dramatically influenced by the presence of dsb, then how do multiple 'ends' from different chromosomes proximally associate for mis-repair as complex chromosome aberrations? To address these questions, we have analysed the chromosome aberrations induced in peripheral blood lymphocytes after exposure to 0.5 Gy α -particles (mean of 1 α -particle/cell) using the technique of M-FISH. This technique 'paints' all the human chromosomes (excluding homologues) uniquely, allowing chromosomal mis-repair to be visualised as differential colour-junctions and in addition, enhanced DAPI banding enables gross breakpoint assignation of these colour junctions. To test for non-randomness, we are comparing the frequency of occurrence of breakpoints obtained up to now with the F98 glioma model our knowledbased on chromosome length. Similarly, the involvement of each chromosome relative to other chromosomes within individual rearrangements can be determined by assuming the volume of chromosome domains is also proportional to their length. The current data to be presented will

  12. Parsimonious Refraction Interferometry and Tomography

    KAUST Repository

    Hanafy, Sherif

    2017-02-04

    We present parsimonious refraction interferometry and tomography where a densely populated refraction data set can be obtained from two reciprocal and several infill shot gathers. The assumptions are that the refraction arrivals are head waves, and a pair of reciprocal shot gathers and several infill shot gathers are recorded over the line of interest. Refraction traveltimes from these shot gathers are picked and spawned into O(N2) virtual refraction traveltimes generated by N virtual sources, where N is the number of geophones in the 2D survey. The virtual traveltimes can be inverted to give the velocity tomogram. This enormous increase in the number of traveltime picks and associated rays, compared to the many fewer traveltimes from the reciprocal and infill shot gathers, allows for increased model resolution and a better condition number with the system of normal equations. A significant benefit is that the parsimonious survey and the associated traveltime picking is far less time consuming than that for a standard refraction survey with a dense distribution of sources.

  13. Análise comparativa entre a refração clínica subjetiva e a automatizada obtida por sensor de frentes de onda Comparative analyses between clinical refraction and automatic refraction obtained through a wave front sensor

    Directory of Open Access Journals (Sweden)

    Wilson de Freitas

    2007-08-01

    Full Text Available OBJETIVO: Avaliar e comparar os resultados obtidos da refração estática clínica com a obtida por sensor de frentes de onda. MÉTODOS: Estudo prospectivo, não seqüencial, de 279 olhos de 147 pacientes. Todos os pacientes foram examinados sob cicloplegia. Primeiro realizamos a refração clínica e a seguir a automatizada por sensor de frentes de onda. Os dados refracionais obtidos foram decompostos para análise vetorial. Foram analisados separadamente os dados de um olho por paciente e dos dois olhos. RESULTADOS: A diferença entre a refração clínica e a automatizada foi de -0,19 DE combinada com -0,06 DC no eixo de 15º para os dados de um olho por paciente e -0,17 DE combinada com -0,05 DC no eixo de 3º para todos os olhos da amostra. CONCLUSÃO: Os dados da refração clínica são comparáveis com os da refração obtida por um sensor de frentes de onda.PURPOSE: To evaluate and compare refractive errors obtained through clinical subjective and automatized wavefront refraction analyses in eyes under cycloplegia. METHODS: Prospective study of 147 patients, 279 eyes, undergoing preoperative examination for refractive surgery. Clinical subjective refraction was performed first followed by wavefront refraction. Results on astigmatism obtained from refraction were decomposed in power vectors for statistical analyses. Data were first analyzed in one eye and then in both eyes. RESULTS: The mean difference between clinical subjective refraction and automatized wavefront refraction on cycloplegic eyes was of -0.19 SD combined with -0.06 CD in the 15º axis for data in one eye, and -0.17 SD combined with -0.05 CD in the 3º axis for data in both eyes of the same patient. CONCLUSION: In the present study clinical subjective refraction and automatized wavefront refraction under cycloplegia had similar numerical values.

  14. Modificaciones de la curvatura posterior corneal después de la cirugía refractiva láser Modifications in the corneal posterior curve after laser refractive surgery

    Directory of Open Access Journals (Sweden)

    Lorelei Ortega Díaz

    2011-06-01

    Full Text Available OBJETIVO: Describir las modificaciones de la curvatura posterior corneal en pacientes sometidos a cirugía refractiva láser en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" en el período de mayo a octubre de 2010. MÉTODOS: Se realizó un estudio descriptivo, longitudinal y prospectivo, con un universo de 257 pacientes (504 ojos sometidos a cirugía refractiva láser. La muestra quedó conformada por 31 pacientes (59 ojos. Se analizaron variables como edad, sexo, equivalente esférico, paquimetría preoperatoria, cantidad de ablación, estroma residual y diferencia de elevación posterior corneal, esta última obtenida del mapa de diferencia del topógrafo Galilei, con medición preoperatoria al mes y a los tres meses de la cirugía. Mediante análisis de regresión múltiple fueron valorados dichos cambios de la paquimetría, la cantidad de ablación y el estroma residual. RESULTADOS: El equivalente esférico, la paquimetría, la cantidad de ablación y el estroma residual se encontraron dentro de los parámetros de seguridad establecidos. La diferencia promedio de la elevación corneal posterior fue de 15,62 µm al mes y de 11,78 µm a los tres meses, con disminución significativa con el tiempo (p= 0,000. Se observó asociación con la paquimetría preoperatoria y el estroma residual, y se encontró una correlación inversa entre este último y la elevación corneal posterior a los tres meses. CONCLUSIONES: La cirugía refractiva láser induce un aumento precoz en la elevación corneal posterior, con disminución progresiva hacia el tercer mes. Los factores que más influyeron en estos cambios fueron el estroma residual y la paquimetría preoperatoria.OBJECTIVES: To describe the modifications in the corneal posterior curve in patients underwent laser refractive surgery in the "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from May to October, 2020. METHODS: A prospective, longitudinal and descriptive study was conducted

  15. Differential changes in free and total insulin-like growth factor I after major, elective abdominal surgery

    DEFF Research Database (Denmark)

    Skjærbæk, Christian; Frystyk, Jan; Ørskov, Hans

    1998-01-01

    Major surgery is accompanied by extensive proteolysis of insulin-like growth factor (IGF)-binding protein-3 (IGFBP-3). Proteolysis of IGFBP-3 is generally believed to increase IGF bioavailability due to a diminished affinity of the IGFBP-3 fragments for IGFs. We have investigated 18 patients...... undergoing elective ileo-anal J-pouch surgery. Patients were randomized to treatment with GH (12 IU/day; n = 9) or placebo (n = 9) from 2 days before to 7 days after operation. Free IGF-I and IGF-II were measured by ultrafiltration of serum, and IGFBP-3 proteolytic activity was determined by a [125I...

  16. Personalized pseudophakic model for refractive assessment.

    Directory of Open Access Journals (Sweden)

    Filomena J Ribeiro

    Full Text Available PURPOSE: To test a pseudophakic eye model that allows for intraocular lens power (IOL calculation, both in normal eyes and in extreme conditions, such as post-LASIK. METHODS: PARTICIPANTS: The model's efficacy was tested in 54 participants (104 eyes who underwent LASIK and were assessed before and after surgery, thus allowing to test the same method in the same eye after only changing corneal topography. MODELLING: The Liou-Brennan eye model was used as a starting point, and biometric values were replaced by individual measurements. Detailed corneal surface data were obtained from topography (Orbscan® and a grid of elevation values was used to define corneal surfaces in an optical ray-tracing software (Zemax®. To determine IOL power, optimization criteria based on values of the modulation transfer function (MTF weighted according to contrast sensitivity function (CSF, were applied. RESULTS: Pre-operative refractive assessment calculated by our eye model correlated very strongly with SRK/T (r = 0.959, p0.05. Comparison of post-operative refractive assessment obtained using our eye model with the average of currently used formulas showed a strong correlation (r = 0.778, p0.05. CONCLUSIONS: Results suggest that personalized pseudophakic eye models and ray-tracing allow for the use of the same methodology, regardless of previous LASIK, independent of population averages and commonly used regression correction factors, which represents a clinical advantage.

  17. Influence of Refraction on the Applicability of the Zehnder-Mach Interferometer to Studies of Cooled Boundary Layers

    National Research Council Canada - National Science Library

    Kinsler, Martin

    1951-01-01

    .... It was found that for low wall to free-stream temperature ratios, the effects of light refraction may cause considerable error in the boundary-layer density profiles calculated from interferogram...

  18. Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Zina Zhang

    2017-01-01

    Full Text Available Purpose: To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. Methods: Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refractive analysis (ORA system. Analysis was performed to determine the accuracy of monofocal IOL power prediction and postoperative manifest refraction at 1 month of the ORA versus IOLMaster. Results: Two hundred and ninety-five eyes reviewed, 61 had only preoperative IOLMaster measurements and 234 had both IOLMaster and ORA measurements. Of these 234 eyes, 6 were excluded, 107 had the same recommended IOL power by ORA and IOLMaster. Sixty-four percent of these eyes were within ±0.5D. 95 eyes had IOL power implantation based on ORA instead of IOLMaster. Seventy percent of these eyes were within ±0.5D of target refraction. 26 eyes had IOL power chosen based on IOLMaster predictions instead of ORA. Sixty-five percent were within ±0.5D. In the group with IOLMaster without ORA measurements, 80% of eyes were within ±0.5D of target refraction. The absolute error was statistically smaller in those eyes where the ORA and IOLMaster recommended the same IOL power based on preoperative target refraction compared to instances in which IOL selection was based on ORA or IOLMaster alone. Neither prediction errors were statistically different between the ORA and IOLMaster alone. Conclusion: Intraoperative wavefront aberrometry with the ORA system provides postoperative refractive results comparable to conventional biometry with the IOLMaster for monofocal IOL selection.

  19. Wavefront-guided refractive surgery results of training-surgeons Resultados das cirurgias refrativas guiadas por frentes de ondas de cirurgiões em treinamento

    Directory of Open Access Journals (Sweden)

    Iane Stillitano

    2010-08-01

    Full Text Available PURPOSE: To assess clinical outcomes and changes on higher-order aberrations (HOA after wavefront-guided laser in situ keratomileusis (LASIK and photorefractive keratectomy (PRK for correction of myopia and myopic astigmatism performed by training-surgeons. METHODS: One hundred and seventy patients had customized LASIK (207 eyes and PRK (103 eyes performed by surgeons in-training using the LADARVision 4000 (Alcon, Fort Worth, TX. Preoperative and 1, 3, 6 and 12 months postoperative data of spherical equivalent (SE, best spectacle-corrected visual acuity (BSCVA and uncorrected visual acuity (UCVA were analysed. Wavefront changes were determined using the LADARWave Hartmann-Shack wavefront aberrometer and the pupil size was scaled for 6.5 mm. RESULTS: The mean SE in the LASIK group was -3.04 ±1.07 D and in the PRK group was -1.60 ± 0.59 D. At 1-year follow-up, (80.6% (LASIK and (66.7% (PRK were within ± 0.50 D of the intended refraction. The UCVA was 20/20 or better in (58.1% (LASIK and (66.7% (PRK of the operated eyes. A statistically significant positive correlation was found between achieved versus attempted refractive correction in both groups: LASIK (r=0.975, POBJETIVO: Avaliar os resultados clínicos e mudanças nas aberrações de alta-ordem (HOA, após ceratomileuse assistida por excimer laser in situ (LASIK e ceratectomia fotorrefrativa (PRK guiados por frentes de onda para correção da miopia e astigmatismo miópico realizada por cirurgiões em treinamento. MÉTODOS: Estudo prospectivo de 170 pacientes submetidos a LASIK personalizado (207 olhos e PRK (103 olhos realizados por cirurgiões em treinamento utilizando o LADARVision 4000 (Alcon, Fort Worth, TX. Dados do equivalente esférico (SE, melhor acuidade visual corrigida (BSCVA e acuidade visual não corrigida (UCVA foram analisados no pré-operatório e com 1, 3, 6 e 12 meses de pós-operatório. As alterações de frentes de onda foram determinadas usando o aberrômetro Hartmann

  20. Peripheral refraction in normal infant rhesus monkeys

    Science.gov (United States)

    Hung, Li-Fang; Ramamirtham, Ramkumar; Huang, Juan; Qiao-Grider, Ying; Smith, Earl L.

    2008-01-01

    Purpose To characterize peripheral refractions in infant monkeys. Methods Cross-sectional data for horizontal refractions were obtained from 58 normal rhesus monkeys at 3 weeks of age. Longitudinal data were obtained for both the vertical and horizontal meridians from 17 monkeys. Refractive errors were measured by retinoscopy along the pupillary axis and at eccentricities of 15, 30, and 45 degrees. Axial dimensions and corneal power were measured by ultrasonography and keratometry, respectively. Results In infant monkeys, the degree of radial astigmatism increased symmetrically with eccentricity in all meridians. There were, however, initial nasal-temporal and superior-inferior asymmetries in the spherical-equivalent refractive errors. Specifically, the refractions in the temporal and superior fields were similar to the central ametropia, but the refractions in the nasal and inferior fields were more myopic than the central ametropia and the relative nasal field myopia increased with the degree of central hyperopia. With age, the degree of radial astigmatism decreased in all meridians and the refractions became more symmetrical along both the horizontal and vertical meridians; small degrees of relative myopia were evident in all fields. Conclusions As in adult humans, refractive error varied as a function of eccentricity in infant monkeys and the pattern of peripheral refraction varied with the central refractive error. With age, emmetropization occurred for both central and peripheral refractive errors resulting in similar refractions across the central 45 degrees of the visual field, which may reflect the actions of vision-dependent, growth-control mechanisms operating over a wide area of the posterior globe. PMID:18487366

  1. Single-step transepithelial photorefractive keratectomy in myopia and astigmatism: 18-month follow-up.

    Science.gov (United States)

    Adib-Moghaddam, Soheil; Soleyman-Jahi, Saeed; Salmanian, Bahram; Omidvari, Amir-Houshang; Adili-Aghdam, Fatemeh; Noorizadeh, Farsad; Eslani, Medi

    2016-11-01

    To evaluate the long-term quantitative and qualitative optical outcomes of 1-step transepithelial photorefractive keratectomy (PRK) to correct myopia and astigmatism. Bina Eye Hospital, Tehran, Iran. Prospective interventional case series. Eyes with myopia with or without astigmatism were evaluated. One-step transepithelial PRK was performed with an aberration-free aspheric optimized profile and the Amaris 500 laser. Eighteen-month follow-up results for refraction, visual acuities, vector analysis, higher-order aberrations, contrast sensitivity, postoperative pain, and haze grade were assessed. The study enrolled 146 eyes (74 patients). At the end of follow-up, 93.84% of eyes had an uncorrected distance visual acuity of 20/20 or better and 97.94% of eyes were within ±0.5 diopter of the targeted spherical refraction. On vector analysis, the mean correction index value was close to 1 and the mean index of success and magnitude of error values were close to 0. The achieved correction vector was on an axis counterclockwise to the axis of the intended correction. Photopic and mesopic contrast sensitivities and ocular and corneal spherical, cylindrical, and corneal coma aberrations significantly improved (all P < .001). A slight amount of trefoil aberration was induced (P < .001, ocular aberration; P < .01, corneal aberration). No eye lost more than 1 line of corrected distance visual acuity. No eye had a haze grade of 2+ degrees or higher throughout the follow-up. Eighteen-month results indicate the efficacy and safety of transepithelial PRK to correct myopia and astigmatism. It improved refraction and quality of vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Iteration of ultrasound aberration correction methods

    Science.gov (United States)

    Maasoey, Svein-Erik; Angelsen, Bjoern; Varslot, Trond

    2004-05-01

    Aberration in ultrasound medical imaging is usually modeled by time-delay and amplitude variations concentrated on the transmitting/receiving array. This filter process is here denoted a TDA filter. The TDA filter is an approximation to the physical aberration process, which occurs over an extended part of the human body wall. Estimation of the TDA filter, and performing correction on transmit and receive, has proven difficult. It has yet to be shown that this method works adequately for severe aberration. Estimation of the TDA filter can be iterated by retransmitting a corrected signal and re-estimate until a convergence criterion is fulfilled (adaptive imaging). Two methods for estimating time-delay and amplitude variations in receive signals from random scatterers have been developed. One method correlates each element signal with a reference signal. The other method use eigenvalue decomposition of the receive cross-spectrum matrix, based upon a receive energy-maximizing criterion. Simulations of iterating aberration correction with a TDA filter have been investigated to study its convergence properties. A weak and strong human-body wall model generated aberration. Both emulated the human abdominal wall. Results after iteration improve aberration correction substantially, and both estimation methods converge, even for the case of strong aberration.

  3. Emmetropisation and the aetiology of refractive errors

    Science.gov (United States)

    Flitcroft, D I

    2014-01-01

    The distribution of human refractive errors displays features that are not commonly seen in other biological variables. Compared with the more typical Gaussian distribution, adult refraction within a population typically has a negative skew and increased kurtosis (ie is leptokurtotic). This distribution arises from two apparently conflicting tendencies, first, the existence of a mechanism to control eye growth during infancy so as to bring refraction towards emmetropia/low hyperopia (ie emmetropisation) and second, the tendency of many human populations to develop myopia during later childhood and into adulthood. The distribution of refraction therefore changes significantly with age. Analysis of the processes involved in shaping refractive development allows for the creation of a life course model of refractive development. Monte Carlo simulations based on such a model can recreate the variation of refractive distributions seen from birth to adulthood and the impact of increasing myopia prevalence on refractive error distributions in Asia. PMID:24406411

  4. Fat-Free Mass and Skeletal Muscle Mass Five Years After Bariatric Surgery.

    Science.gov (United States)

    Davidson, Lance E; Yu, Wen; Goodpaster, Bret H; DeLany, James P; Widen, Elizabeth; Lemos, Thaisa; Strain, Gladys W; Pomp, Alfons; Courcoulas, Anita P; Lin, Susan; Janumala, Isaiah; Thornton, John C; Gallagher, Dympna

    2018-07-01

    This study investigated changes in fat-free mass (FFM) and skeletal muscle 5 years after surgery in participants from the Longitudinal Assessment of Bariatric Surgery-2 trial. A three-compartment model assessed FFM, and whole-body magnetic resonance imaging (MRI) quantified skeletal muscle mass prior to surgery (T0) and 1 year (T1), 2 years (T2), and 5 years (T5) postoperatively in 93 patients (85% female; 68% Caucasian; age 44.2 ± 11.6 years) who underwent gastric bypass (RYGB), sleeve gastrectomy, or adjustable gastric band. Repeated-measures mixed models were used to analyze the data. Significant weight loss occurred across all surgical groups in females from T0 to T1. FFM loss from T0 to T1 was greater after RYGB (mean ± SE: -6.9 ± 0.6 kg) than adjustable gastric band (-3.5 ± 1.4 kg; P FFM (-3.3 ± 0.7 kg; P FFM loss while maintaining FFM and skeletal muscle from T1 to T5. Between 1 and 5 years following common bariatric procedures, FFM and skeletal muscle are maintained or decrease minimally. The changes observed in FFM and muscle during the follow-up phase may be consistent with aging. © 2018 The Obesity Society.

  5. Advanced personalized nomogram for myopic laser surgery: First 100 eyes

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; van der Linden, Jan Willem; van der Meulen, Ivanka J. E.; Nieuwendaal, Carla P.

    2008-01-01

    PURPOSE: To report the results in the first 100 eyes treated for myopia using a new advanced nomogram. SETTING: Private refractive surgery clinic. METHODS: This prospective interventional case series comprised 58 patients (100 eyes) consecutively treated for myopia with laser in situ keratomileusis

  6. Spherical aberration compensation method for long focal-length measurement based on Talbot interferometry

    Science.gov (United States)

    Luo, Yupeng; Huang, Xiao; Bai, Jian; Du, Juan; Liu, Qun; Luo, Yujie; Luo, Jia

    2017-08-01

    Large-aperture and long focal-length lens is widely used in high energy laser system. The method based on Talbot interferometry is a reliable method to measure the focal length of such elements. By employing divergent beam and two gratings of different periods, this method could realize full-aperture measurement, higher accuracy and better repeatability. However, it does not take into account the spherical aberration of the measured lens resulting in the moiré fringes bending, which will introduce measurement error. Furthermore, in long-focal measurement with divergent beam, this error is an important factor affecting the measurement accuracy. In this paper, we propose a new spherical aberration compensation method, which could significantly reduce the measurement error. Characterized by central-symmetric scanning window, the proposed method is based on the relationship between spherical aberration and the lens aperture. Angle data of moiré fringes in each scanning window is retrieved by Fourier analysis and statistically fitted to estimate a globally optimum value for spherical-aberration-free focal length calculation. Simulation and experiment have been carried out. Compared to the previous work, the proposed method is able to reduce the relative measurement error by 50%. The effect of scanning window size and shift step length on the results is also discussed.

  7. Atmospheric refraction : a history

    NARCIS (Netherlands)

    Lehn, WH; van der Werf, S

    2005-01-01

    We trace the history of atmospheric refraction from the ancient Greeks up to the time of Kepler. The concept that the atmosphere could refract light entered Western science in the second century B.C. Ptolemy, 300 years later, produced the first clearly defined atmospheric model, containing air of

  8. Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laser

    Science.gov (United States)

    Arbelaez, María Clara; Vidal, Camila; Arba Mosquera, Samuel

    2011-01-01

    Purpose To evaluate postoperative clinical outcomes, and corneal High Order Aberrations, among eyes with hyperopia up to +5 D of spherical equivalent, that have undergone LASIK treatments using the SCHWIND AMARIS laser system. Methods At six-month follow-up, 100 eyes with preoperative hyperopia or hyperopic astigmatism up to +5 D of spherical equivalent were retrospectively analysed. Standard examinations, pre- and postoperative wavefront analysis with a corneal-wavefront-analyzer (OPTIKON Scout) were performed. Aberration-Free aspheric treatments were planned with Custom Ablation Manager software and ablations performed using the SCHWIND AMARIS flying-spot excimer laser system (both SCHWIND eye-tech-solutions). LASIK flaps were created using a LDV femtosecond laser (Ziemer Group) in all cases. Clinical outcomes were evaluated in terms of predictability, refractive outcome, safety, and wavefront aberration. Results At six month, 90 % of eyes achieved ≥ 20/25 UCVA and 44 % achieved ≥ 20/16 UCVA. Seventy-four percent of eyes were within ± 0.25D of spherical equivalent and 89 % within ± 0.50D, with 94 % within 0.50D of astigmatism. Mean spherical equivalent was −0.12 ± 0.51D and 0.50 ± 0.51D for the astigmatism. Fifty-two percent of eyes improved BSCVA vs. only 19 % losing lines of BSCVA. Predictability slope for refraction was 1.03 and intercept +0.01 D. On average, negative corneal spherical aberrations were significantly increased by the treatments, no other aberration terms changed from pre- to postoperative values. Conclusions LASIK for hyperopia and hyperopic astigmatism with SCHWIND AMARIS yields very satisfactory visual outcomes. Preoperative refractions were postoperatively reduced to subclinical values with no clinically relevant induction of corneal HOA.

  9. [Monochromatic aberration in accommodation. Dynamic wavefront analysis].

    Science.gov (United States)

    Fritzsch, M; Dawczynski, J; Jurkutat, S; Vollandt, R; Strobel, J

    2011-06-01

    Monochromatic aberrations may influence the visual acuity of the eye. They are not stable and can be affected by different factors. The subject of the following paper is the dynamic investigation of the changes in wavefront aberration with accommodation. Dynamic measurement of higher and lower order aberrations was performed with a WASCA Wavefront Analyzer (Carl-Zeiss-Meditec) and a specially constructed target device for aligning objects in far and near distances on 25 subjects aged from 15 to 27 years old. Wavefront aberrations showed some significant changes in accommodation. In addition to the characteristic sphere reaction accompanying miosis and changes in horizontal prism (Z(1) (1)) in the sense of a convergence movement of the eyeball also occurred. Furthermore defocus rose (Z(2) (0)) and astigmatism (Z(2) (-2)) changed. In higher-order aberrations a decrease in coma-like Zernike polynomials (Z(3) (-1), Z(3) (1)) was found. The most obvious change appeared in spherical aberration (Z(4) (0)) which increased and changed from positive to negative. In addition the secondary astigmatism (Z(4) (-2)) and quadrafoil (Z(4) (4)) rise also increased. The total root mean square (RMS), as well as the higher-order aberrations (RMS-HO) significantly increased in accommodation which is associated with a theoretical reduction of visual acuity. An analysis of the influence of pupil size on aberrations showed significant increases in defocus, spherical aberration, quadrafoil, RMS and RMS HO by increasing pupil diameter. By accommodation-associated miosis, the growing aberrations are partially compensated by focusing on near objects. Temporal analysis of the accommodation process with dynamic wavefront analysis revealed significant delays in pupil response and changing of prism in relation to the sphere reaction. In accommodation to near objects a discrete time ahead of third order aberrations in relation to the sphere response was found. Using dynamic wavefront measurement

  10. Evaluation of Optical Quality: Ocular Scattering and Aberrations in Eyes Implanted with Diffractive Multifocal or Monofocal Intraocular Lenses.

    Science.gov (United States)

    Liao, Xuan; Lin, Jia; Tian, Jing; Wen, BaiWei; Tan, QingQing; Lan, ChangJun

    2018-06-01

    To compare objective optical quality, ocular scattering and aberrations of eyes implanted with an aspheric monofocal intraocular lens (IOL) or an aspheric apodized diffractive multifocal IOL three months after surgery. Prospective consecutive nonrandomized comparative cohort study. A total of 80 eyes from 57 cataract patients were bilaterally or unilaterally implanted with monofocal (AcrySof IQ SN60WF) or multifocal (AcrySof IQ ReSTOR SN6AD1) IOLs. Respectively, 40 eyes of 27 patients were implanted with monofocal IOLs, and 40 eyes of 30 patients were implanted with multifocal IOLs. Ocular high-order aberration (HOA) values were obtained using Hartmann-Shack aberrometer; objective scatter index (OSI), modulation transfer function (MTF) cutoff, Strehl ratio (SR), and contrast visual acuity OV at 100%, 20%, and 9% were measured using Objective Quality Analysis System II (OQAS II). Ocular aberrations performed similar in both groups (p > 0.05). However, significantly higher values of OSI and lower values of MTF cutoff, SR and OV were found in the SN6AD1 group (p < 0.05). Both ocular scattering and wave-front aberrations play essential role in retinal image quality, which may be overestimated when only aberrations were taken into account. Combining the effect of ocular scattering with HOA will result in a more accurate assessment of the visual and optical quality.

  11. Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

    Directory of Open Access Journals (Sweden)

    Teresa Ferrer-Blasco

    2013-04-01

    Full Text Available PURPOSE: To evaluate distance and near contrast sensitivity (CS under photopic and mesopic conditions before and after refractive lens exchange (RLE and implantation of the aspheric AcrySof®ReSTOR® (SN6AD3 model intraocular lens (IOL. METHODS:Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m² before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. RESULTS: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002. CONCLUSIONS: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.

  12. Reversing the direction of space and inverse Doppler effect in positive refraction index media

    International Nuclear Information System (INIS)

    Sun, Fei; He, Sailing

    2017-01-01

    A negative refractive index medium, in which all spatial coordinates are reversed (i.e. a left-hand triplet is formed) by a spatial folding transformation, can create many novel electromagnetic phenomena, e.g. backward wave propagation, and inversed Doppler effect (IDE). In this study, we use coordinate rotation transformation to reverse only two spatial coordinates (e.g. x ′ and y ′), while keeping z ′ unchanged. In this case, some novel phenomena, e.g. radiation-direction-reversing illusions and IDE, can be achieved in a free space region wrapped by the proposed shell without any negative refractive index medium, which is easier for experimental realization and future applications. (paper)

  13. The uncorrected refractive error challenge

    Directory of Open Access Journals (Sweden)

    Kovin Naidoo

    2016-11-01

    Full Text Available Refractive error affects people of all ages, socio-economic status and ethnic groups. The most recent statistics estimate that, worldwide, 32.4 million people are blind and 191 million people have vision impairment. Vision impairment has been defined based on distance visual acuity only, and uncorrected distance refractive error (mainly myopia is the single biggest cause of worldwide vision impairment. However, when we also consider near visual impairment, it is clear that even more people are affected. From research it was estimated that the number of people with vision impairment due to uncorrected distance refractive error was 107.8 million,1 and the number of people affected by uncorrected near refractive error was 517 million, giving a total of 624.8 million people.

  14. The Correlation Analysis between Corneal Biomechanical Properties and the Surgically Induced Corneal High-Order Aberrations after Small Incision Lenticule Extraction and Femtosecond Laser In Situ Keratomileusis

    Directory of Open Access Journals (Sweden)

    Wenjing Wu

    2015-01-01

    Full Text Available Background. To investigate the correlation between corneal biomechanics and the surgically induced corneal high-order aberrations (HOAs after small incision lenticule extraction (SMILE and femtosecond laser in situ keratomileusis (FS-LASIK. Methods. A total of 150 right myopic eyes that underwent SMILE or FS-LASIK surgery were included in this retrospective study, 75 eyes in each group. The corneal hysteresis (CH and the corneal resistance factor (CRF with the corneal HOAs of the anterior, posterior, and total cornea were assessed preoperatively and three months postoperatively. Multivariate linear regression was applied to determine the correlations. Results. The preoperative CRF was significantly correlated with the induced 3rd–6th-order HOAs and spherical aberration of the anterior surface and the total cornea after SMILE and FS-LASIK surgeries (P<0.05, postoperatively. The CRF was significantly correlated with the induced vertical coma of the anterior and posterior surfaces and the total cornea after SMILE surgery (P<0.05. There was a significant correlation between the CRF and the induced posterior corneal horizontal coma after FS-LASIK surgery (P=0.013. Conclusions. The corneal biomechanics affect the surgically induced corneal HOAs after SMILE and FS-LASIK surgery, which may be meaningful for screening the patients preoperatively and optimizing the visual qualities postoperatively.

  15. The prediction of spherical aberration with schematic eyes.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1996-07-01

    Many model eyes have been proposed; they differ in optical characteristics and therefore have different aberrations and image quality. In predicting the visual performance of the eye, we are most concerned with the central foveal vision. Spherical aberration is the only on-axis monochromatic aberration and can be used as a criterion to assess the degree of resemblance of eye models to the human eye. We reviewed and compiled experimental values of the spherical aberration of the eye, calculated the spherical aberration of several different categories of model eyes and compared the calculated results to the experimental data. Results show an over-estimation of spherical aberration by all models, the finite schematic eyes predicting values of spherical aberration closest to the experimental data. Current model eyes do not predict the average experimental values of the spherical aberration of the eye. A new model eye satisfying this assessment criterion is required for investigations of the visual performance of the eye.

  16. Effect of Ramadan fasting in tropical summer months on ocular refractive and biometric characteristics.

    Science.gov (United States)

    Nowroozzadeh, Mohammad Hosein; Mirhosseini, Amirhossein; Meshkibaf, Mohammad Hassan; Roshannejad, Javad

    2012-03-01

    Islamic Ramadan is the month of fasting, in which intake of food and drink is restricted from sunrise until sunset. The objective of the present study was to find out the effect of altered eating habits during Ramadan fasting on ocular refractive and biometric properties. In this prospective case series, 40 eyes of 22 healthy volunteers with a mean age of 60.55 ± 12.20 years were enrolled. Patients with any systemic disorder and eyes with pathology or previous surgery were excluded. One month before Ramadan (at 8.00 am), during Ramadan fasting (at 8.00 am and 4.00 pm) and one month later during the non-fasting period (at 8.00 am), ocular refractive and biometric characteristics were measured using an autokeratorefractometer (Auto-Kerato-Refractometer KR-8900; Topcon Co, Tokyo, Japan) and contact ultrasonic biometry (Nidek Echoscan US 800; Nidek Co, Tokyo, Japan). Anterior chamber depth was significantly increased during fasting compared with baseline measurements and returned to baseline one month after Ramadan (3.22 ± 0.07 mm and 4.33 ± 0.17 mm for non-fasting and fasting, respectively; p Ramadan (23.09 ± 0.14 mm and 22.65 ± 0.18 mm, for non-fasting and fasting, respectively; p Ramadan (SRK-T formula: 21.46 ± 0.27 D and 22.92 ± 0.46 D, for non-fasting and fasting, respectively; p Ramadan fasting is associated with statistically significant alterations in anterior chamber depth and axial length that result in both statistically and clinically significant changes in intraocular lens power calculations. Therefore, relying on measurements taken during this month might lead to refractive errors after cataract surgery. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

  17. Imaging characteristics of Zernike and annular polynomial aberrations.

    Science.gov (United States)

    Mahajan, Virendra N; Díaz, José Antonio

    2013-04-01

    The general equations for the point-spread function (PSF) and optical transfer function (OTF) are given for any pupil shape, and they are applied to optical imaging systems with circular and annular pupils. The symmetry properties of the PSF, the real and imaginary parts of the OTF, and the modulation transfer function (MTF) of a system with a circular pupil aberrated by a Zernike circle polynomial aberration are derived. The interferograms and PSFs are illustrated for some typical polynomial aberrations with a sigma value of one wave, and 3D PSFs and MTFs are shown for 0.1 wave. The Strehl ratio is also calculated for polynomial aberrations with a sigma value of 0.1 wave, and shown to be well estimated from the sigma value. The numerical results are compared with the corresponding results in the literature. Because of the same angular dependence of the corresponding annular and circle polynomial aberrations, the symmetry properties of systems with annular pupils aberrated by an annular polynomial aberration are the same as those for a circular pupil aberrated by a corresponding circle polynomial aberration. They are also illustrated with numerical examples.

  18. Types of structural chromosome aberrations and their incidences in human spermatozoa X-irradiated in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Kamiguchi, Yujiroh; Tateno, Hiroyuki; Mikamo, Kazuya (Asahikawa Medical College (Japan). Department of Biological Sciences)

    1990-02-01

    The authors studied the effects of in vitro X-irradiation on human sperm chromosomes, using our interspecific in vitro fertilization system between human spermatozoa and zona-free hamster oocytes. 28 semen samples from 5 healthy men were exposed to 0.23, 0.45, 0.91 and 1.82 Gy of X-rays. Totals of 2098 and 2862 spermatozoa were karyotyped in the control and the irradiated groups, respectively. The indicence of spermatozoa with X-ray-induced structural chromosome aberrations (Y) increased linearly with increasing dosage (D), being best expressed by the equation, Y = 0.08 + 34.52 D. The incidence of breakage-type aberrations was moe than 9 times higher than that of exchange-type aberrations. Both of them showed linear dose-dependent increases, which were expressed by the regression lines, Y = -0.014 + 0.478 D and Y -0.010 + 0.057 D, respectively. The incidence of chromosome-ltype aberrations was about 6 times higher than that of chromatid-type aberrations. Their dose-dependent increases were expressed by the regression lines, Y = -0.015 + 0.462 D and Y = -0.006 + 0.079 D, respectively. These results are discussed in relation to the previous data obtained with {gamma}-rays. The repair mechanism of X-ray-induced sperm DNA lesions is also discussed. (author). 21 refs.; 4 figs.; 4 tabs.

  19. Geometric characteristics of aberrations of plane-symmetric optical systems

    International Nuclear Information System (INIS)

    Lu Lijun; Deng Zhiyong

    2009-01-01

    The geometric characteristics of aberrations of plane-symmetric optical systems are studied in detail with a wave-aberration theory. It is dealt with as an extension of the Seidel aberrations to realize a consistent aberration theory from axially symmetric to plane-symmetric systems. The aberration distribution is analyzed with the spot diagram of a ray and an aberration curve. Moreover, the root-mean-square value and the centroid of aberration distribution are discussed. The numerical results are obtained with the focusing optics of a toroidal mirror at grazing incidence.

  20. Negative refraction angular characterization in one-dimensional photonic crystals.

    Directory of Open Access Journals (Sweden)

    Jesus Eduardo Lugo

    2011-04-01

    Full Text Available Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs.By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone.Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  1. Negative refraction angular characterization in one-dimensional photonic crystals.

    Science.gov (United States)

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-04-06

    Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity developed here. We also analytically derived the negative refraction correctness condition that gives the angular region where negative refraction occurs. By using standard photonic techniques we experimentally determined the relationship between incidence and negative refraction angles and found the negative refraction range by applying the correctness condition. In order to compare both theories with experimental results an output refraction correction was utilized. The correction uses Snell's law and an effective refractive index based on two effective dielectric constants. We found good agreement between experiment and both theories in the negative refraction zone. Since both theories and the experimental observations agreed well in the negative refraction region, we can use both negative refraction theories plus the output correction to predict negative refraction angles. This can be very useful from a practical point of view for space filtering applications such as a photonic demultiplexer or for sensing applications.

  2. Nodal aberration theory applied to freeform surfaces

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P.; Thompson, Kevin P.

    2014-12-01

    When new three-dimensional packages are developed for imaging optical systems, the rotational symmetry of the optical system is often broken, changing its imaging behavior and making the optical performance worse. A method to restore the performance is to use freeform optical surfaces that compensate directly the aberrations introduced from tilting and decentering the optical surfaces. In order to effectively optimize the shape of a freeform surface to restore optical functionality, it is helpful to understand the aberration effect the surface may induce. Using nodal aberration theory the aberration fields induced by a freeform surface in an optical system are explored. These theoretical predications are experimentally validated with the design and implementation of an aberration generating telescope.

  3. Small-aperture corneal inlay in patients with prior radial keratotomy surgeries

    Directory of Open Access Journals (Sweden)

    Huseynova T

    2013-09-01

    Full Text Available Tukezban Huseynova,1,* Tomomi Kanamori,1 George O Waring IV,2 Minoru Tomita1,3,* 1Shinagawa LASIK Center, Chiyoda-ku, Tokyo, Japan; 2Medical University of South Carolina, Storm Eye Institute, Charleston, SC, USA; 3Department of Ophthalmology, Wenzhou Medical College, Wenzhou, People's Republic of China *These authors contributed equally to this study Abstract: This paper describes the 3-month results of two patients who underwent KAMRA™ (AcuFocus, Inc, Irvine, CA, USA inlay implantation surgery with a history of prior radial keratotomy. The refractive error just before KAMRA inlay implantation was corrected in one patient with a laser-assisted in situ keratomileusis (LASIK procedure. The post-inlay implantation surgery results showed effective uncorrected near visual acuity outcomes with no impact on uncorrected distance visual acuity in both patients. Keywords: KAMRA™, RK, LASIK, uncorrected distance visual acuity, refractive error, uncorrected near visual acuity

  4. Transfer of unstable chromosomal aberrations in human peripheral lymphocytes at cell division and their significance for the aberration frequency

    International Nuclear Information System (INIS)

    Stephan, G.; Chang Tsangpi.

    1986-04-01

    In 48 h cultures, the fraction of human lymphocytes in 2nd mitosis was found to be between 0 and 42.5% (mean value 8.7%). The X-ray exposure from irradiating with 2 Gy resulted in a cell cycle delay which varied from donor to donor. A loss of nearly 50% of dicentric chromosomes and acentric fragments from unstable chromosomes occurred at cell division, while centric rings were not impeded. When dicentric chromosomes, or acentric fragments are found in 2nd mitosis, they show a characteristic differential staining, which means that chromatides at cell division fall free and are replicated in daughter cells. When plotting dose effect curves of dicentric chromosomes, up to 20% of 2nd mitosis fractions have little influence on the aberration rate. This may be additionally verified as part of the 'biological dosimetry' in a person with 24% of 2nd mitosis. When the rates of dicentric chromosomes exclusively evaluated from 1st mitosis after irradiation with 2.0 Gy were related to the donors age, no age-dependent sensitivity to radiation could be observed. Aberration rates which deviate from person to person are comparable to the results achieved by conventional staining methods. (orig./MG) [de

  5. Reflective type objective based spectral-domain phase-sensitive optical coherence tomography for high-sensitive structural and functional imaging of cochlear microstructures through intact bone of an excised guinea pig cochlea

    Science.gov (United States)

    Subhash, Hrebesh M.; Wang, Ruikang K.; Chen, Fangyi; Nuttall, Alfred L.

    2013-03-01

    Most of the optical coherence tomographic (OCT) systems for high resolution imaging of biological specimens are based on refractive type microscope objectives, which are optimized for specific wave length of the optical source. In this study, we present the feasibility of using commercially available reflective type objective for high sensitive and high resolution structural and functional imaging of cochlear microstructures of an excised guinea pig through intact temporal bone. Unlike conventional refractive type microscopic objective, reflective objective are free from chromatic aberrations due to their all-reflecting nature and can support a broadband of spectrum with very high light collection efficiency.

  6. Aberration characteristics of immersion lenses for LVSEM

    International Nuclear Information System (INIS)

    Khursheed, Anjam

    2002-01-01

    This paper investigates the on-axis aberration characteristics of various immersion objective lenses for low voltage scanning electron microscopy (LVSEM). A simple aperture lens model is used to generate smooth axial field distributions. The simulation results show that mixed field electric-magnetic immersion lenses are predicted to have between 1.5 and 2 times smaller aberration limited probe diameters than their pure-field counterparts. At a landing energy of 1 keV, mixed field immersion lenses operating at the vacuum electrical field breakdown limit are predicted to have on-axis aberration coefficients between 50 and 60 μm, yielding an ultimate image resolution of below 1 nm. These aberrations lie in the same range as those for LVSEM systems that employ aberration correctors

  7. FREE ANTEROLATERAL FEMORAL FLAP IS THE FIRST CHOICE IN EMERGENCY RECONSTRUCTIVE SURGERY OF THE LOWER LIMB (ANALYSIS OF CLINICAL CASES

    Directory of Open Access Journals (Sweden)

    A. V. Nevedrov

    2015-01-01

    Full Text Available BACKGROUND. Requirements for the graft used in microsurgery are simple retrieval, minimal anatomic variability, the possibility to operate on one surgical area, great length and diameter of flap vessels.PURPOSE OF STUDY. Evaluation of the results and advantages of revascularized free anterolateral muscle flap usage in emergency surgery.MATERIALS AND METHODS. Free muscle flap of the lateral vastus muscle on a vascular pedicle of the descending branch of the lateral femoral circumflex artery (anterolateral flap was used to replace the defect in 2 patients. In one case, a patient had open fractures of the lower leg, complicated with primary defects of soft tissue, and in the other case a patient had incomplete traumatic amputation of the left foot. All the victims underwent soft tissue defects restoration within the first hours after the injury, next to fixation of the fracture.RESULTS. All grafts have completely healed, total necrosis of muscle flaps hasn’t been observed. All patients had primary wound healing after the transfer. Cases of deep purulent infection after the surgery haven’t been noted.CONCLUSION. The transfer of a free anterolateral muscle flap is the best method for emergency plastic and reconstructive surgery of the lower limbs. The advantages are simple and prompt retreival, no need to turn the patient to the lateral position, large amount of the flap, great length and caliber of vessels. 

  8. Freeform aberrations in phase space: an example.

    Science.gov (United States)

    Babington, James

    2017-06-01

    We consider how optical propagation and aberrations of freeform systems can be formulated in phase space. As an example system, a freeform prism is analyzed and discussed. Symmetry considerations and their group theory descriptions are given some importance. Numerical aberrations are also highlighted and put into the context of the underlying aberration theory.

  9. Spherical aberrations of human astigmatic corneas.

    Science.gov (United States)

    Zhao, Huawei; Dai, Guang-Ming; Chen, Li; Weeber, Henk A; Piers, Patricia A

    2011-11-01

    To evaluate whether the average spherical aberration of human astigmatic corneas is statistically equivalent to human nonastigmatic corneas. Spherical aberrations of 445 astigmatic corneas prior to laser vision correction were retrospectively investigated to determine Zernike coefficients for central corneal areas 6 mm in diameter using CTView (Sarver and Associates). Data were divided into groups according to cylinder power (0.01 to 0.25 diopters [D], 0.26 to 0.75 D, 0.76 to 1.06 D, 1.07 to 1.53 D, 1.54 to 2.00 D, and >2.00 D) and according to age by decade. Spherical aberrations were correlated with age and astigmatic power among groups and the entire population. Statistical analyses were conducted, and P.05 for all tested groups). Mean spherical aberration of astigmatic corneas was not correlated significantly with cylinder power or age (P>.05). Spherical aberrations are similar to those of nonastigmatic corneas, permitting the use of these additional data in the design of aspheric toric intra-ocular lenses. Copyright 2011, SLACK Incorporated.

  10. Wave-vector and polarization dependence of conical refraction.

    Science.gov (United States)

    Turpin, A; Loiko, Yu V; Kalkandjiev, T K; Tomizawa, H; Mompart, J

    2013-02-25

    We experimentally address the wave-vector and polarization dependence of the internal conical refraction phenomenon by demonstrating that an input light beam of elliptical transverse profile refracts into two beams after passing along one of the optic axes of a biaxial crystal, i.e. it exhibits double refraction instead of refracting conically. Such double refraction is investigated by the independent rotation of a linear polarizer and a cylindrical lens. Expressions to describe the position and the intensity pattern of the refracted beams are presented and applied to predict the intensity pattern for an axicon beam propagating along the optic axis of a biaxial crystal.

  11. Femtosecond laser cataract surgery: technology and clinical practice.

    Science.gov (United States)

    Roberts, Timothy V; Lawless, Michael; Chan, Colin Ck; Jacobs, Mark; Ng, David; Bali, Shveta J; Hodge, Chris; Sutton, Gerard

    2013-03-01

    The recent introduction of femtosecond lasers to cataract surgery has generated much interest among ophthalmologists around the world. Laser cataract surgery integrates high-resolution anterior segment imaging systems with a femtosecond laser, allowing key steps of the procedure, including the primary and side-port corneal incisions, the anterior capsulotomy and fragmentation of the lens nucleus, to be performed with computer-guided laser precision. There is emerging evidence of reduced phacoemulsification time, better wound architecture and a more stable refractive result with femtosecond cataract surgery, as well as reports documenting an initial learning curve. This article will review the current state of technology and discuss our clinical experience. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  12. Spherical aberration correction with an in-lens N-fold symmetric line currents model.

    Science.gov (United States)

    Hoque, Shahedul; Ito, Hiroyuki; Nishi, Ryuji

    2018-04-01

    In our previous works, we have proposed N-SYLC (N-fold symmetric line currents) models for aberration correction. In this paper, we propose "in-lens N-SYLC" model, where N-SYLC overlaps rotationally symmetric lens. Such overlap is possible because N-SYLC is free of magnetic materials. We analytically prove that, if certain parameters of the model are optimized, an in-lens 3-SYLC (N = 3) doublet can correct 3rd order spherical aberration. By computer simulation, we show that the required excitation current for correction is less than 0.25 AT for beam energy 5 keV, and the beam size after correction is smaller than 1 nm at the corrector image plane for initial slope less than 4 mrad. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Whole eye wavefront aberrations in Mexican male subjects.

    Science.gov (United States)

    Cantú, Roberto; Rosales, Marco A; Tepichín, Eduardo; Curioca, Andrée; Montes, Victor; Bonilla, Julio

    2004-01-01

    To analyze the characteristics, incidence, and appearance of wavefront aberrations in undilated, normal, unoperated eyes. Eighty-eight eyes of 44 healthy male Mexican subjects (mean age 25.32 years, range 18 to 36 yr) were divided into three groups based on uncorrected visual acuity of greater than or equal to 20/20, 20/30, or 20/40. UCVA measurements were obtained using an Acuity Max computer screen chart. Wavefront aberrations were measured with the Nidek OPD-Scan ARK 10000, Ver. 1.11b. All measurements were carried out at the same center by the same technician during a single session, following manufacturer instructions. Background illumination was 3 Lux. Wavefront aberration measurements for each group were statistically analyzed using StatView; an average eye was characterized and the resulting aberrations were simulated using MATLAB. We obtained wavefront aberration maps for the 20/20 undilated normal unoperated eyes for total, low, and high order aberration coefficients. Wavefront maps for right eyes were practically the same as those for left eyes. Higher aberrations did not contribute substantially to total wavefront analysis. Average aberrations of this "normal eye" will be used as criteria to decide the necessity of wavefront-guided ablation in our facilities. We will focus on the nearly zero average of high order aberrations in this normal whole eye as a reference to be matched.

  14. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism.

    Science.gov (United States)

    Xia, Li-Kun; Ma, Jing; Liu, He-Nan; Shi, Ce; Huang, Qing

    2018-01-01

    To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant ( t =-1.59, P =0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group ( t =5.76, P =0.00), and 0.14 D in the SMILE group ( t =0.54, P =0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group ( P =0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P =0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better

  15. GENERAL SURGERY

    African Journals Online (AJOL)

    in the endoscopy room. GENERAL SURGERY. T du Toit, O C Buchel, S J A Smit. Department of Surgery, University of the Free State, Bloemfontein, ... The lack of video instrumentation in developing countries: Redundant fibre-optic instruments (the old. “eye scope”) are still being used. This instrument brings endoscopists ...

  16. Modeling the influence of LASIK surgery on optical properties of the human eye

    Science.gov (United States)

    Szul-Pietrzak, Elżbieta; Hachoł, Andrzej; Cieślak, Krzysztof; Drożdż, Ryszard; Podbielska, Halina

    2011-11-01

    The aim was to model the influence of LASIK surgery on the optical parameters of the human eye and to ascertain which factors besides the central corneal radius of curvature and central thickness play the major role in postsurgical refractive change. Ten patients were included in the study. Pre- and postsurgical measurements included standard refraction, anterior corneal curvature and pachymetry. The optical model used in the analysis was based on the Le Grand and El Hage schematic eye, modified by the measured individual parameters of corneal geometry. A substantial difference between eye refractive error measured after LASIK and estimated from the eye model was observed. In three patients, full correction of the refractive error was achieved. However, analysis of the visual quality in terms of spot diagrams and optical transfer functions of the eye optical system revealed some differences in these measurements. This suggests that other factors besides corneal geometry may play a major role in postsurgical refraction. In this paper we investigated whether the biomechanical properties of the eyeball and changes in intraocular pressure could account for the observed discrepancies.

  17. Human resources for refraction services in Central Nepal.

    Science.gov (United States)

    Kandel, Himal; Murthy, G V S; Bascaran, Covadonga

    2015-07-01

    Uncorrected refractive error is a public health problem globally and in Nepal. Planning of refraction services is hampered by a paucity of data. This study was conducted to determine availability and distribution of human resources for refraction, their efficiency, the type and extent of their training; the current service provision of refraction services and the unmet need in human resources for refraction in Central Nepal. This was a descriptive cross-sectional study. All refraction facilities in the Central Region were identified through an Internet search and interviews of key informants from the professional bodies and parent organisations of primary eye centres. A stratified simple random sampling technique was used to select 50 per cent of refraction facilities. The selected facilities were visited for primary data collection. Face-to-face interviews were conducted with the managers and the refractionists available in the facilities using a semi-structured questionnaire. Data was collected in 29 centres. All the managers (n=29; response rate 100 per cent) and 50 refractionists (Response rate 65.8 per cent) were interviewed. Optometrists and ophthalmic assistants were the main providers of refraction services (n=70, 92.11 per cent). They were unevenly distributed across the region, highly concentrated around urban areas. The median number of refractions per refractionist per year was 3,600 (IQR: 2,400 - 6,000). Interviewed refractionists stated that clients' knowledge, attitude and practice related factors such as lack of awareness of the need for refraction services and/or availability of existing services were the major barriers to the output of refraction services. The total number of refractions carried out in the Central Region per year was 653,176. An additional 170 refractionists would be needed to meet the unmet need of 1,323,234 refractions. The study findings demand a major effort to develop appropriately trained personnel when planning

  18. Measuring and correcting aberrations of a cathode objective lens

    International Nuclear Information System (INIS)

    Tromp, R.M.

    2011-01-01

    In this paper I discuss several theoretical and practical aspects related to measuring and correcting the chromatic and spherical aberrations of a cathode objective lens as used in Low Energy Electron Microscopy (LEEM) and Photo Electron Emission Microscopy (PEEM) experiments. Special attention is paid to the various components of the cathode objective lens as they contribute to chromatic and spherical aberrations, and affect practical methods for aberration correction. This analysis has enabled us to correct a LEEM instrument for the spherical and chromatic aberrations of the objective lens. -- Research highlights: → Presents a comprehensive theory of the relation between chromatic aberration and lens current in a cathode objective lens. → Presents practical methods for measuring both spherical and chromatic aberrations of a cathode objective lens. → Presents measurements of these aberrations in good agreement with theory. → Presents practical methods for measuring and correcting these aberrations with an electron mirror.

  19. Thermodynamic study of three pharmacologically significant drugs: Density, viscosity, and refractive index measurements at different temperatures

    International Nuclear Information System (INIS)

    Iqbal, Muhammad Javed; Chaudhry, Mansoora Ahmed

    2009-01-01

    Measurements of density, viscosity, and refractive index of three pharmacologically significant drugs, i.e. diclofenac sodium, cetrizine, and doxycycline have been carried in aqueous medium at T = (293.15 to 313.15) K. An automated vibrating-tube densimeter, viscometer, and refractometer are used in a concentration range from (7.5) . 10 -3 to 25 . 10 -3 ) mol . kg -1 . The precise density results are used to evaluate the apparent molar volume, partial molar volume, thermal expansion coefficient, partial molar expansivity, and the Hepler's constant. Viscosity results are used to calculate the Jones-Dole viscosity B-coefficient, free energy of activation of the solute and solvent, activation enthalpy, and activation entropy. The molar refractive indices of the drug solutions can be employed to calculate molar refraction. It is inferred from these results that the above mentioned drugs act as structure-making compounds due to hydrophobic hydration of the molecules in the drugs

  20. Fully 3D refraction correction dosimetry system

    International Nuclear Information System (INIS)

    Manjappa, Rakesh; Makki, S Sharath; Kanhirodan, Rajan; Kumar, Rajesh; Vasu, Ram Mohan

    2016-01-01

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  1. Fully 3D refraction correction dosimetry system.

    Science.gov (United States)

    Manjappa, Rakesh; Makki, S Sharath; Kumar, Rajesh; Vasu, Ram Mohan; Kanhirodan, Rajan

    2016-02-21

    The irradiation of selective regions in a polymer gel dosimeter results in an increase in optical density and refractive index (RI) at those regions. An optical tomography-based dosimeter depends on rayline path through the dosimeter to estimate and reconstruct the dose distribution. The refraction of light passing through a dose region results in artefacts in the reconstructed images. These refraction errors are dependant on the scanning geometry and collection optics. We developed a fully 3D image reconstruction algorithm, algebraic reconstruction technique-refraction correction (ART-rc) that corrects for the refractive index mismatches present in a gel dosimeter scanner not only at the boundary, but also for any rayline refraction due to multiple dose regions inside the dosimeter. In this study, simulation and experimental studies have been carried out to reconstruct a 3D dose volume using 2D CCD measurements taken for various views. The study also focuses on the effectiveness of using different refractive-index matching media surrounding the gel dosimeter. Since the optical density is assumed to be low for a dosimeter, the filtered backprojection is routinely used for reconstruction. We carry out the reconstructions using conventional algebraic reconstruction (ART) and refractive index corrected ART (ART-rc) algorithms. The reconstructions based on FDK algorithm for cone-beam tomography has also been carried out for comparison. Line scanners and point detectors, are used to obtain reconstructions plane by plane. The rays passing through dose region with a RI mismatch does not reach the detector in the same plane depending on the angle of incidence and RI. In the fully 3D scanning setup using 2D array detectors, light rays that undergo refraction are still collected and hence can still be accounted for in the reconstruction algorithm. It is found that, for the central region of the dosimeter, the usable radius using ART-rc algorithm with water as RI matched

  2. Pressure dependence of the refractive index in wurtzite and rocksalt indium nitride

    International Nuclear Information System (INIS)

    Oliva, R.; Segura, A.; Ibáñez, J.; Artús, L.; Yamaguchi, T.; Nanishi, Y.

    2014-01-01

    We have performed high-pressure Fourier transform infrared reflectance measurements on a freestanding InN thin film to determine the refractive index of wurtzite InN and its high-pressure rocksalt phase as a function of hydrostatic pressure. From a fit to the experimental refractive-index curves including the effect of the high-energy optical gaps, phonons, free carriers, and the direct (fundamental) band-gap in the case of wurtzite InN, we obtain pressure coefficients for the low-frequency (electronic) dielectric constant ε ∞ . Negative pressure coefficients of −8.8 × 10 −2  GPa −1 and −14.8 × 10 −2  GPa −1 are obtained for the wurtzite and rocksalt phases, respectively. The results are discussed in terms of the electronic band structure and the compressibility of both phases

  3. Laser-assisted cataract surgery: benefits and barriers.

    Science.gov (United States)

    Hatch, Kathryn M; Talamo, Jonathan H

    2014-01-01

    The use of the femtosecond laser (FSL) in cataract surgery may represent the largest advancement in the field since the inception of phacoemulsification. The goal of this review is to outline the benefits of and barriers to this technology. There are several significant potential benefits of the FSL in cataract surgery over conventional manual cataract surgery: precise capsulotomy formation, clear corneal and limbal relaxing incision construction, lens fragmentation, and lens softening. Evidence suggests that refractive benefits include more precise effective lens position as well as reduced effective phacoemulsification time with the use of FSL compared with manual surgery. Patients with conditions such as Fuchs' endothelial dystrophy, pseudoexfoliation, history of trauma, or brunescent cataracts may particularly benefit from this technology. There are significant financial and logistical issues to consider prior to the purchase of a FSL, including the cost of the laser, and charges to patients, and how the laser affects the patient flow in the operating room. The FSL may significantly change the current approach to cataract surgery.

  4. Dark refraction shift with allowance for astigmatism

    Directory of Open Access Journals (Sweden)

    W.D.H. Gillan

    2005-12-01

    Full Text Available Purpose: To show that the dark refraction shift (dark focus is a more complicated phenomenon than implied when presented as spherical. Methods: Fifty autorefractor measurements of refractive state of the right eye were obtained in light  and  dark  conditions.  Multivariate  methods were used to analyze the data and stereo-pair scat-ter plots, polar meridional profiles and other means of presenting results are used to show important characteristics of the dark refraction shift. Results: The complexity of the dark refrac-tion shift is indicated by stereo-pair scatter plots showing the amount of stigmatic and antistigmatic variation that occurs in light and dark conditions. The mean dark refraction shift is presented in a complete manner including all three components of refractive state. The greater variance and covari-ance under dark conditions is clearly shown by the term-by-term dark-light variance-covariance ratio and polar profiles  of variance and covariance.Conclusions: The  dark  refraction  shift  is  a more complicated phenomenon than implied by representations as purely spherical in nature.

  5. Estudio topoaberrométrico en Lasik después de queratotomía radial Topoaberrometric study in Lasik after radial keratotomy

    Directory of Open Access Journals (Sweden)

    Yamila Díaz Parra

    2007-12-01

    Full Text Available La cirugía refractiva personalizada consiste en adecuar el tratamiento de cada paciente según las características de la córnea y corregir defectos que afectan la calidad de la visión; por ejemplo, las aberraciones ópticas. Se seleccionaron 21 ojos de 13 pacientes con miopía residual después de queratotomía radial. Se realizó agudeza visual sin corrección y con ella, queratometría, refracción dinámica, refracción ciclopléjica; topografía corneal, taquimetría, tonometría, biomicroscopia, estudio de la lágrima y fondoscopia. A todos se les aplicó el software de análisis de frente de onda corneal y se realizó Lasik (Queratomileusis in situ con láser y queratectomía refractiva optimizada. La agudeza visual sin corrección varió de 0,17 a 0,75. El equivalente esférico promedio se modificó de -4,81 D a -0,67 D. Las aberraciones de alto orden (HORMS prequirúrgicas y posquirúrgicas variaron de 0,970 um hasta 1,130 um. La agudeza visual sin corrección fue superior a 0,8 en todos los casos después de la cirugía de Lasik. Disminuyó el equivalente esférico y el componente cilíndrico en todos los ojos. Las aberraciones totales disminuyeron también en todos los casos.Customized refractive surgery means adapting treatment to the patient according to the corneal characteristics and correcting defects that affect the quality of vision, for example, optical aberrations. Twenty one eyes from 13 patients with residual myopia after undergoing radial keratotomy were selected. Visual acuity without correction and also, keratometry, dynamic refraction, cycloplegic refraction, corneal topography, tachymetry, tonometry, biomicroscopy, study of the tear and funduscopy were performed. All the eyes were applied the sofware for analysis of corneal wavefront and Lasik (Queratomileusis in situ with laser and optimized refractive keratectomy were performed. Visual acuity without correction changed from 0.17 to 0.75. Average sphere equivalent

  6. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali

    2012-02-26

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green\\'s functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  7. Super-Virtual Refraction Interferometric Redatuming: Enhancing the Refracted Energy

    KAUST Repository

    Aldawood, Ali; Alshuhail, Abdulrahman Abdullatif Abdulrahman; Hanafy, Sherif

    2012-01-01

    onshore seismic data processing. Refraction tomography is becoming a common way to estimate an accurate near surface velocity model. One of the problems with refraction tomography is the low signal to noise ration in far offset data. To improve, we propose using super-virtual refraction interferometry to enhance the weak energy at far offsets. We use Interferometric Green's functions to redatum sources by cross-correlating two traces recorded at receiver stations, A and B, from a source at location W. The result is a redatumed trace with a virtual source at A and a receiver at B, which can also be obtained by correlating two traces recorded at A and B from different shots. Stacking them would enhance the signal-to-noise ratio of this "virtual" trace. We next augment redatuming with convolution and stacking. The trace recorded at B from a virtual source at A is convolved with the original trace recorded at A from a source at W. The result is a "super-virtual" trace at B in the far-offset from a source at W. Stacking N traces gives a vN-improvement. We applied our method to noisy synthetic and field data recorded over a complex near-surface and we could pick more traces at far offsets. It was possible to accommodate more picks resulting in a better subsurface coverage

  8. Chromosomal aberrations in ore miners of Slovakia

    International Nuclear Information System (INIS)

    Beno, M.; Vladar, M.; Nikodemova, D.; Vicanova, M.; Durcik, M.

    1998-01-01

    A pilot study was performed in which the incidence of chromosomal aberrations in lymphocytes of miners in ore mines located in Central Slovakia was monitored and related to lifetime underground radon exposure and to lifetime smoking. The conclusions drawn from the results of the study were as follows: the counts of chromosomal aberrations in lymphocytes of miners were significantly higher than in an age matched control group of white-collar staff; the higher counts of chromosomal aberrations could be ascribed to underground exposure of miners and to smoking; a dependence of chromosomal aberration counts on the exposure to radon could not be assessed. (A.K.)

  9. Aberration studies and computer algebra

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    1981-01-01

    The labour of calculating expressions for aberration coefficients is considerably lightened if a computer algebra language is used to perform the various substitutions and expansions involved. After a brief discussion of matrix representations of aberration coefficients, a particular language, which has shown itself to be well adapted to particle optics, is described and applied to the study of high frequency cavity lenses. (orig.)

  10. Flow cytogenetics: progress toward chromosomal aberration detection

    International Nuclear Information System (INIS)

    Carrano, A.V.; Gray, J.W.; Van Dilla, M.A.

    1977-01-01

    Using clonal derivatives of the Chinese hamster M3-1 cell line, we demonstrate the potential of flow systems to karyotype homogeneous aberrations (aberrations which are identical and present in every cell) and to detect heterogeneous aberrations (aberrations which occur randomly in a population and are not identical in every cell). Flow cytometry (FCM) of ethidium bromide stained isolated chromosomes from clone 650A of the M3-1 cells distinguishes nine chromosome types from the fourteen present in the actual karyotype. X-irradiation of this parent 650A clone produced two sub-clones with an altered flow karyotype, that is, their FCM distributions were characterized by the addition of new peaks and alterations in area under existing peaks. From the relative DNA content and area for each peak, as determined by computer analysis, we predicted that each clone had undergone a reciprocal translocation involving chromosomes from two peaks. This prediction was confirmed by Giemsa-banding the metaphase cells. Heterogeneous aberrations are reflected in the flow karyotype as an increase in background, that is, an increase in area underlying the chromosome peaks. This increase is dose dependent but, as yet, the sample variability has been too large for quantitative analysis. Flow sorting of the valleys between chromosome peaks produces enriched fractions of aberrant chromosomes for visual analysis. These approaches are potentially applicable to the analysis of chromsomal aberrations induced by environmental contaminants

  11. Aberration-corrected STEM: current performance and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Nellist, P D [Department of Physics, University of Dublin, Trinity College, Dublin 2 (Ireland); Chisholm, M F [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Lupini, A R [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Borisevich, A [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Jr, W H Sides [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Pennycook, S J [Condensed Matter Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6030 (United States); Dellby, N [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Keyse, R [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Krivanek, O L [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Murfitt, M F [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States); Szilagyi, Z S [Nion Co., 1102 8th St., Kirkland, WA 98033 (United States)

    2006-02-22

    Through the correction of spherical aberration in the scanning transmission electron microscope (STEM), the resolving of a 78 pm atomic column spacing has been demonstrated along with information transfer to 61 pm. The achievement of this resolution required careful control of microscope instabilities, parasitic aberrations and the compensation of uncorrected, higher order aberrations. Many of these issues are improved in a next generation STEM fitted with a new design of aberration corrector, and an initial result demonstrating aberration correction to a convergence semi-angle of 40 mrad is shown. The improved spatial resolution and beam convergence allowed for by such correction has implications for the way in which experiments are performed and how STEM data should be interpreted.

  12. Refracting surface plasmon polaritons with nanoparticle arrays

    DEFF Research Database (Denmark)

    Radko, I.P.; Evlyukhin, A.B.; Boltasseva, Alexandra

    2008-01-01

    Refraction of surface plasmon polaritons (SPPs) by various structures formed by a 100-nm-period square lattice of gold nanoparticles on top of a gold film is studied by leakage radiation microscopy. SPP refraction by a triangular-shaped nanoparticle array indicates that the SPP effective refractive...... to design nanoparticle arrays for specific applications requiring in-plane SPP manipulation....

  13. Measurement of the effective refractive index of a turbid colloidal suspension using light refraction

    International Nuclear Information System (INIS)

    Reyes-Coronado, A; Garcia-Valenzuela, A; Sanchez-Perez, C; Barrera, R G

    2005-01-01

    We propose and analyse a simple method to measure simultaneously the real and imaginary parts of the effective refractive index of a turbid suspension of particles. The method is based on measurements of the angle of refraction and transmittance of a laser beam that traverses a hollow glass prism filled with a colloidal suspension. We provide a comprehensive assessment of the method. It can offer high sensitivity while still being simple to interpret. We present results of experiments using an optically turbid suspension of polystyrene particles and compare them with theoretical predictions. We also report experimental evidence showing that the refractive behaviour of the diffuse component of light coming from a suspension depends on the volume fraction of the colloidal particles

  14. Adaptive deformable mirror dynamics and modular control

    NARCIS (Netherlands)

    Ellenbroek, R.M.L.

    2011-01-01

    The refractive index of air varies a.o. with temperature, humidity, pressure and the CO2 concentration. Due to atmospheric turbulence this refractive index varies both in space and in time, leading to aberrations in images of light having passed though it. These aberrations limit the achievable

  15. Nodal aberration theory for wild-filed asymmetric optical systems

    Science.gov (United States)

    Chen, Yang; Cheng, Xuemin; Hao, Qun

    2016-10-01

    Nodal Aberration Theory (NAT) was used to calculate the zero field position in Full Field Display (FFD) for the given aberration term. Aiming at wide-filed non-rotational symmetric decentered optical systems, we have presented the nodal geography behavior of the family of third-order and fifth-order aberrations. Meanwhile, we have calculated the wavefront aberration expressions when one optical element in the system is tilted, which was not at the entrance pupil. By using a three-piece-cellphone lens example in optical design software CodeV, the nodal geography is testified under several situations; and the wavefront aberrations are calculated when the optical element is tilted. The properties of the nodal aberrations are analyzed by using Fringe Zernike coefficients, which are directly related with the wavefront aberration terms and usually obtained by real ray trace and wavefront surface fitting.

  16. Review on the refractive treatment methods of aphakia

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Deng

    2015-06-01

    Full Text Available The refractive treatment methods of aphakia include corrective glasses, contact lens correction and intraocular lens(IOLimplantation. It magnifies images highly and limits vision field with corrective glasses. For infant aphakia corrective glasses are more likely to be chosen because their eyes are still unable to tolerate IOL implantation in the developmental stage. With low magnification of images, contact lens includes soft contact lens and rigid contact lens. The former is rarely used because it is prone to ocular lesions due to its poor oxygen permeability. The latter is widely used due to its good oxygen permeability especially suitable for the eyes of irregular astigmatism or iris missing due to trauma. At present, the most commonly used in clinical work is IOL implantation. The eye of IOL may avoid anisometropia, aberrations and so on because of more physiological anatomy. According to the IOL implantation site, it is divided into the anterior chamber IOL implantation and the posterior chamber IOL implantation. The anterior chamber IOL implantation is divided into angle fixed IOL implantation and iris fixed IOL implantation. The posterior chamber IOL implantation is divided into secondary in-the-bag IOL implantation, the ciliary sulcus IOL implantation and transscleral suture fixed IOL implantation.

  17. Aspheric photorefractive keratectomy for myopia and myopic astigmatism with the SCHWIND AMARIS laser: 2 years postoperative outcomes

    Science.gov (United States)

    Aslanides, Ioannis M.; Padroni, Sara; Arba-Mosquera, Samuel

    2012-01-01

    Purpose To evaluate mid-term refractive outcomes and higher order aberrations of aspheric PRK for low, moderate and high myopia and myopic astigmatism with the AMARIS excimer laser system (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). Methods This prospective longitudinal study evaluated 80 eyes of 40 subjects who underwent aspheric PRK. Manifest refractive spherical equivalent (MRSE) of up to −10.00 diopters (D) at the spectacle plane with cylinder up to 3.25 was treated. Refractive outcomes and corneal wavefront data (6 mm pupil to the 7th Zernike order) were evaluated out to 2 years postoperatively. Statistical significance was indicated by P  0.05, both cases). There was a statistical increase in postoperative coma (+0.12 μm) and spherical aberration (+0.14 μm) compared to preoperatively (P < 0.001, both cases). Conclusion Aspheric PRK provides excellent visual and refractive outcomes with induction in individual corneal aberrations but not overall corneal aberrations.

  18. Compound refractive X-ray lens

    International Nuclear Information System (INIS)

    Nygren, D.R.; Cahn, R.; Cederstrom, B.; Danielsson, M.; Vestlund, J.

    2000-01-01

    An apparatus and method are disclosed for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point

  19. Compound refractive X-ray lens

    Science.gov (United States)

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  20. Thermodynamic study of three pharmacologically significant drugs: Density, viscosity, and refractive index measurements at different temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Javed [Department of Chemistry, Quaid-i-Azam University, Islamabad 45320 (Pakistan)], E-mail: mjiqauchem@yahoo.com; Chaudhry, Mansoora Ahmed [Department of Chemistry, Quaid-i-Azam University, Islamabad 45320 (Pakistan)

    2009-02-15

    Measurements of density, viscosity, and refractive index of three pharmacologically significant drugs, i.e. diclofenac sodium, cetrizine, and doxycycline have been carried in aqueous medium at T = (293.15 to 313.15) K. An automated vibrating-tube densimeter, viscometer, and refractometer are used in a concentration range from (7.5) . 10{sup -3} to 25 . 10{sup -3}) mol . kg{sup -1}. The precise density results are used to evaluate the apparent molar volume, partial molar volume, thermal expansion coefficient, partial molar expansivity, and the Hepler's constant. Viscosity results are used to calculate the Jones-Dole viscosity B-coefficient, free energy of activation of the solute and solvent, activation enthalpy, and activation entropy. The molar refractive indices of the drug solutions can be employed to calculate molar refraction. It is inferred from these results that the above mentioned drugs act as structure-making compounds due to hydrophobic hydration of the molecules in the drugs.

  1. The generalized vectorial laws of reflection and refraction

    International Nuclear Information System (INIS)

    Bhattacharjee, Pramode Ranjan

    2005-01-01

    This paper discloses two important discoveries. These are: (i) discovery of ambiguity in the well-established laws of reflection and refraction of light which have been in regular use for many years, and (ii) discovery of generalized vectorial laws of reflection and refraction of light. The existing definitions of angle of incidence, angle of reflection and angle of refraction are considered first. Each of these definitions is found to be ambiguous, not in compliance with the fundamental definition of angle in geometry. Two typical questions (one in the case of reflection and the other for refraction) have been addressed, which cannot be dealt with by using the existing laws of reflection and refraction of light. Thus, the existing laws of reflection and refraction of light seem to be ambiguous in respect of generality and their validity in a broad sense is questionable. With a view to removing the ambiguities, proper definitions of the above three angles are given first and then the statement of the generalized vectorial law of reflection (as well as that of refraction) has been offered

  2. Adaptive aberration correction using a triode hyperbolic electron mirror

    International Nuclear Information System (INIS)

    Fitzgerald, J.P.S.; Word, R.C.; Koenenkamp, R.

    2011-01-01

    A converging electron mirror can be used to compensate spherical and chromatic aberrations in an electron microscope. This paper presents an analytical solution to a novel triode (three electrode) hyperbolic mirror as an improvement to the well-known diode (two electrode) hyperbolic mirror for aberration correction. A weakness of the diode mirror is a lack of flexibility in changing the chromatic and spherical aberration coefficients independently without changes in the mirror geometry. In order to remove this limitation, a third electrode can be added. We calculate the optical properties of the resulting triode mirror analytically on the basis of a simple model field distribution. We present the optical properties-the object/image distance, z 0 , and the coefficients of spherical and chromatic aberration, C s and C c , of both mirror types from an analysis of electron trajectories in the mirror field. From this analysis, we demonstrate that while the properties of both designs are similar, the additional parameters in the triode mirror improve the range of aberration that can be corrected. The triode mirror is also able to provide a dynamic adjustment range of chromatic aberration for fixed spherical aberration and focal length, or any permutation of these three parameters. While the dynamic range depends on the values of aberration correction needed, a nominal 10% tuning range is possible for most configurations accompanied by less than 1% change in the other two properties. -- Highlights: → Electrostatic aberration correction for chromatic and spherical aberration in electron optics. → Simultaneous correction of spherical and chromatic aberrations over a wide, adjustable range. → Analytic and quantitative description of correction parameters.

  3. Optical guiding and beam bending in free-electron lasers

    International Nuclear Information System (INIS)

    Scharlemann, E.T.

    1987-01-01

    The electron beam in a free-electron laser (FEL) can act as an optical fiber, guiding or bending the optical beam. The refractive and gain effects of the bunched electron beam can compensate for diffraction, making possible wigglers that are many Rayleigh ranges (i.e., characteristic diffraction lengths) long. The origin of optical guiding can be understood by examining gain and refractive guiding in a fiber with a complex index of refraction, providing a mathematical description applicable also to the FEL, with some extensions. In the exponential gain regime of the FEL, the electron equations of motion must be included, but a self-consistent description of exponential gain with diffraction fully included becomes possible. The origin of the effective index of refraction of an FEL is illustrated with a simple example of bunched, radiating dipoles. Some of the properties of the index of refraction are described. The limited experimental evidence for optical beam bending is summarized. The evidence does not yet provide conclusive proof of the existence of optical guiding, but supports the idea. Finally, the importance of refractive guiding for the performance of a high-gain tapered-wiggler FEL amplifier is illustrated with numerical simulations

  4. Physics of negative refractive index materials

    International Nuclear Information System (INIS)

    Ramakrishna, S Anantha

    2005-01-01

    In the past few years, new developments in structured electromagnetic materials have given rise to negative refractive index materials which have both negative dielectric permittivity and negative magnetic permeability in some frequency ranges. The idea of a negative refractive index opens up new conceptual frontiers in photonics. One much-debated example is the concept of a perfect lens that enables imaging with sub-wavelength image resolution. Here we review the fundamental concepts and ideas of negative refractive index materials. First we present the ideas of structured materials or meta-materials that enable the design of new materials with a negative dielectric permittivity, negative magnetic permeability and negative refractive index. We discuss how a variety of resonance phenomena can be utilized to obtain these materials in various frequency ranges over the electromagnetic spectrum. The choice of the wave-vector in negative refractive index materials and the issues of dispersion, causality and energy transport are analysed. Various issues of wave propagation including nonlinear effects and surface modes in negative refractive materials (NRMs) are discussed. In the latter part of the review, we discuss the concept of a perfect lens consisting of a slab of a NRM. This perfect lens can image the far-field radiative components as well as the near-field evanescent components, and is not subject to the traditional diffraction limit. Different aspects of this lens such as the surface modes acting as the mechanism for the imaging of the evanescent waves, the limitations imposed by dissipation and dispersion in the negative refractive media, the generalization of this lens to optically complementary media and the possibility of magnification of the near-field images are discussed. Recent experimental developments verifying these ideas are briefly covered

  5. Pressure dependence of the refractive index in wurtzite and rocksalt indium nitride

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, R. [Institut Jaume Almera, Consell Superior d' Investigacions Científiques (CSIC), Lluís Solé i Sabarís s.n., 08028 Barcelona, Catalonia (Spain); MALTA-Consolider Team, Departament de Física Aplicada, ICMUV, Universitat de València, c/Dr. Moliner 50, 46100 Burjassot, València (Spain); Segura, A. [MALTA-Consolider Team, Departament de Física Aplicada, ICMUV, Universitat de València, c/Dr. Moliner 50, 46100 Burjassot, València (Spain); Ibáñez, J., E-mail: jibanez@ictja.csic.es; Artús, L. [Institut Jaume Almera, Consell Superior d' Investigacions Científiques (CSIC), Lluís Solé i Sabarís s.n., 08028 Barcelona, Catalonia (Spain); Yamaguchi, T.; Nanishi, Y. [Faculty of Science and Engineering, Ritsumeikan University, Shiga 525-8577 (Japan)

    2014-12-08

    We have performed high-pressure Fourier transform infrared reflectance measurements on a freestanding InN thin film to determine the refractive index of wurtzite InN and its high-pressure rocksalt phase as a function of hydrostatic pressure. From a fit to the experimental refractive-index curves including the effect of the high-energy optical gaps, phonons, free carriers, and the direct (fundamental) band-gap in the case of wurtzite InN, we obtain pressure coefficients for the low-frequency (electronic) dielectric constant ε{sub ∞}. Negative pressure coefficients of −8.8 × 10{sup −2 }GPa{sup −1} and −14.8 × 10{sup −2 }GPa{sup −1} are obtained for the wurtzite and rocksalt phases, respectively. The results are discussed in terms of the electronic band structure and the compressibility of both phases.

  6. Rooting Out Aberrant Behavior in Training.

    Science.gov (United States)

    Kokalis, Jerry, Jr.; Paquin, Dave

    1989-01-01

    Discusses aberrant, or disruptive, behavior in an industrial/business, classroom-based, instructor-led training setting. Three examples of aberrant behavior are described, typical case studies are provided for each, and preventive (long-term) and corrective (on-the-spot) strategies for dealing with the problems are discussed. (LRW)

  7. Refractive accuracy with light-adjustable intraocular lenses.

    Science.gov (United States)

    Villegas, Eloy A; Alcon, Encarna; Rubio, Elena; Marín, José M; Artal, Pablo

    2014-07-01

    To evaluate efficacy, predictability, and stability of refractive treatments using light-adjustable intraocular lenses (IOLs). University Hospital Virgen de la Arrixaca, Murcia, Spain. Prospective nonrandomized clinical trial. Eyes with a light-adjustable IOL (LAL) were treated with spatial intensity profiles to correct refractive errors. The effective changes in refraction in the light-adjustable IOL after every treatment were estimated by subtracting those in the whole eye and the cornea, which were measured with a Hartmann-Shack sensor and a corneal topographer, respectively. The refractive changes in the whole eye and light-adjustable IOL, manifest refraction, and visual acuity were obtained after every light treatment and at the 3-, 6-, and 12-month follow-ups. The study enrolled 53 eyes (49 patients). Each tested light spatial pattern (5 spherical; 3 astigmatic) produced a different refractive change (Plight adjustments induced a maximum change in spherical power of the light-adjustable IOL of between -1.98 diopters (D) and +2.30 D and in astigmatism of up to -2.68 D with axis errors below 9 degrees. Intersubject variability (standard deviation) ranged between 0.10 D and 0.40 D. The 2 required lock-in procedures induced a small myopic shift (range +0.01 to +0.57 D) that depended on previous adjustments. Light-adjustable IOL implantation achieved accurate refractive outcomes (around emmetropia) with good uncorrected distance visual acuity, which remained stable over time. Further refinements in nomograms and in the treatment's protocol would improve the predictability of refractive and visual outcomes with these IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. The correction of electron lens aberrations

    Energy Technology Data Exchange (ETDEWEB)

    Hawkes, P.W., E-mail: peter.hawkes@cemes.fr

    2015-09-15

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies.

  9. The correction of electron lens aberrations

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    2015-01-01

    The progress of electron lens aberration correction from about 1990 onwards is chronicled. Reasonably complete lists of publications on this and related topics are appended. A present for Max Haider and Ondrej Krivanek in the year of their 65th birthdays. By a happy coincidence, this review was completed in the year that both Max Haider and Ondrej Krivanek reached the age of 65. It is a pleasure to dedicate it to the two leading actors in the saga of aberration corrector design and construction. They would both wish to associate their colleagues with such a tribute but it is the names of Haider and Krivanek (not forgetting Joachim Zach) that will remain in the annals of electron optics, next to that of Harald Rose. I am proud to know that both regard me as a friend as well as a colleague. - Highlights: • Geometrical aberration correction. • Chromatic aberration correction. • 50 pm resolution. • High-resolution electron energy-loss spectroscopy. • Extensive bibliographies

  10. Refractive index contrast in porous silicon multilayers

    Energy Technology Data Exchange (ETDEWEB)

    Nava, R.; Mora, M.B. de la; Tagueena-Martinez, J. [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Rio, J.A. del [Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Temixco, Morelos (Mexico); Centro Morelense de Innovacion y Transferencia Tecnologica, Consejo de Ciencia y Tecnologia del Estado de Morelos (Mexico)

    2009-07-15

    Two of the most important properties of a porous silicon multilayer for photonic applications are flat interfaces and a relative large refractive index contrast between layers in the optical wavelength range. In this work, we studied the effect of the current density and HF electrolyte concentration on the refractive index of porous silicon. With the purpose of increasing the refractive index contrast in a multilayer, the refractive index of porous silicon produced at low current was studied in detail. The current density applied to produce the low porosity layers was limited in order to keep the electrolyte flow through the multilayer structure and to avoid deformation of layer interfaces. We found that an electrolyte composed of hydrofluoric acid, ethanol and glycerin in a ratio of 3:7:1 gives a refractive index contrast around 1.3/2.8 at 600 nm. Several multilayer structures with this refractive index contrast were fabricated, such as dielectric Bragg mirrors and microcavities. Reflectance spectra of the structures show the photonic quality of porous silicon multilayers produced under these electrochemical conditions. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  11. Isaac Newton and the astronomical refraction.

    Science.gov (United States)

    Lehn, Waldemar H

    2008-12-01

    In a short interval toward the end of 1694, Isaac Newton developed two mathematical models for the theory of the astronomical refraction and calculated two refraction tables, but did not publish his theory. Much effort has been expended, starting with Biot in 1836, in the attempt to identify the methods and equations that Newton used. In contrast to previous work, a closed form solution is identified for the refraction integral that reproduces the table for his first model (in which density decays linearly with elevation). The parameters of his second model, which includes the exponential variation of pressure in an isothermal atmosphere, have also been identified by reproducing his results. The implication is clear that in each case Newton had derived exactly the correct equations for the astronomical refraction; furthermore, he was the first to do so.

  12. 3D super-virtual refraction interferometry

    KAUST Repository

    Lu, Kai; AlTheyab, Abdullah; Schuster, Gerard T.

    2014-01-01

    Super-virtual refraction interferometry enhances the signal-to-noise ratio of far-offset refractions. However, when applied to 3D cases, traditional 2D SVI suffers because the stationary positions of the source-receiver pairs might be any place

  13. Refractive Outcomes, Contrast Sensitivity, HOAs, and Patient Satisfaction in Moderate Myopia: Wavefront-Optimized Versus Tissue-Saving PRK.

    Science.gov (United States)

    Nassiri, Nader; Sheibani, Kourosh; Azimi, Abbas; Khosravi, Farinaz Mahmoodi; Heravian, Javad; Yekta, Abasali; Moghaddam, Hadi Ostadi; Nassiri, Saman; Yasseri, Mehdi; Nassiri, Nariman

    2015-10-01

    To compare refractive outcomes, contrast sensitivity, higher-order aberrations (HOAs), and patient satisfaction after photorefractive keratectomy for correction of moderate myopia with two methods: tissue saving versus wavefront optimized. In this prospective, comparative study, 152 eyes (80 patients) with moderate myopia with and without astigmatism were randomly divided into two groups: the tissue-saving group (Technolas 217z Zyoptix laser; Bausch & Lomb, Rochester, NY) (76 eyes of 39 patients) or the wavefront-optimized group (WaveLight Allegretto Wave Eye-Q laser; Alcon Laboratories, Inc., Fort Worth, TX) (76 eyes of 41 patients). Preoperative and 3-month postoperative refractive outcomes, contrast sensitivity, HOAs, and patient satisfaction were compared between the two groups. The mean spherical equivalent was -4.50 ± 1.02 diopters. No statistically significant differences were detected between the groups in terms of uncorrected and corrected distance visual acuity and spherical equivalent preoperatively and 3 months postoperatively. No statistically significant differences were seen in the amount of preoperative to postoperative contrast sensitivity changes between the two groups in photopic and mesopic conditions. HOAs and Q factor increased in both groups postoperatively (P = .001), with the tissue-saving method causing more increases in HOAs (P = .007) and Q factor (P = .039). Patient satisfaction was comparable between both groups. Both platforms were effective in correcting moderate myopia with or without astigmatism. No difference in refractive outcome, contrast sensitivity changes, and patient satisfaction between the groups was observed. Postoperatively, the tissue-saving method caused a higher increase in HOAs and Q factor compared to the wavefront-optimized method, which could be due to larger optical zone sizes in the tissue-saving group. Copyright 2015, SLACK Incorporated.

  14. [Visual outcomes four years after small incision lenticule extraction (SMILE) surgery on highly myopic eyes [French version

    Science.gov (United States)

    Burazovitch, J; Naguzeswski, D; Beuste, T; Guillard, M

    2017-09-01

    To determine whether the visual outcomes of the refractive surgery technique, small incision lenticule extraction (SMILE), are stable, effective, and predictable for high myopia over a four-year period. This is a retrospective study. The data were collected between March 2012 and July 2016. Two hundred and forty-eight patients participated in the study; that is, 496 eyes: 140 eyes of 70 patients (52 women/18 men) were classified in the highly myopic group (refraction measured in spherical equivalent [RMSE]>-6D), and 356 eyes of 178 patients (98 women/80 men) in the control group (RMSE≤-6D). Follow-up tests were conducted immediately post-operatively (D+1), after three months, after one year, and after four years. Refraction, uncorrected visual acuity (UCVA), and best visual corrected acuity (BCVA) were measured. The highly myopic group (HMG) contained more women, and astigmatism was higher for this group than for the control group (CG). These are BCVA, refractive stability, the index of safety (SI: BCVA preoperatively D+1/BCVA postoperatively), and predictability (the percentage of eyes within±0.5 D of the target). In both groups, UCVA was better after the fourth year than it was immediately after the procedure (HMG: P=0.001; CG: P=0.001). Although it differed at one year (P=0.01), the groups' refractive stability tended to converge over four years (P=0.138). Both groups' SI was identical in the four follow-up tests (P=0.734 at D+1; P=0.07 at M+1; P=0.160 at M3 and Y1; and P=0.274 at Y4). For the HMG, SI stability was attained after three months (1.00±0.1); whereas it was attained after one month (0.91±0.11) for the CG. Four years after the surgery, we observed that 87 % of the operated eyes in the HMG were within 0.5 D of the target. SMILE is a good refractive surgery technique for treating high myopia. It yields stable, safe, effective, and predictable results over four years. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Third-rank chromatic aberrations of electron lenses.

    Science.gov (United States)

    Liu, Zhixiong

    2018-02-01

    In this paper the third-rank chromatic aberration coefficients of round electron lenses are analytically derived and numerically calculated by Mathematica. Furthermore, the numerical results are cross-checked by the differential algebraic (DA) method, which verifies that all the formulas for the third-rank chromatic aberration coefficients are completely correct. It is hoped that this work would be helpful for further chromatic aberration correction in electron microscopy. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Planning Strabismus Surgery: How to Avoid Pitfalls and Complications.

    Science.gov (United States)

    Aroichane, Maryam

    2016-01-01

    Good surgical results following strabismus surgery depend on several factors. In this article, detailed steps for planning strabismus surgery will be reviewed for basic horizontal strabismus surgery, vertical, and oblique muscle surgeries. The thought process behind each case will be presented to help in selecting the best surgical approach to optimize postoperative results. The surgical planning for strabismus will be developed with clinical examples from easy cases to more complex ones. Preoperative pictures of the ocular alignment are an integral part of planning surgery and help in documenting the strabismus before and after surgery. Three cases of strabismus cases will be reviewed with several key factors for planning surgery, including visual acuity, refractive error, potential for stereovision, and risk of postoperative diplopia. The most important factor is accurate orthoptic measurements. The surgical planning for each patient is detailed along with preoperative pictures. Strabismus surgery results can be improved by careful preoperative planning. The surgeon has the ability to discern potential pitfalls that can alter the surgical outcome. Surgical planning allows a dedicated time of reflection before surgery, foreseeing potential problems, and avoiding them during the surgery. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.

  17. Clinical Outcomes after Uncomplicated Cataract Surgery with Implantation of the Tecnis Toric Intraocular Lens

    Directory of Open Access Journals (Sweden)

    Wojciech Lubiński

    2016-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes after uncomplicated cataract surgery with implantation of an aspheric toric intraocular lens (IOL during a 6-month follow-up. Methods. Prospective study including 27 consecutive eyes of 18 patients (mean age: 66.1±11.4 years with a visually significant cataract and corneal astigmatism ≥ 0.75 D and undergoing uncomplicated cataract surgery with implantation of the Tecnis ZCT toric IOL (Abbott Medical Optics. Visual, refractive, and keratometric outcomes as well as IOL rotation were evaluated during a 6-month follow-up. At the end of the follow-up, patient satisfaction and perception of optical/visual disturbances were also evaluated using a subjective questionnaire. Results. At 6 months after surgery, mean LogMAR uncorrected (UDVA and corrected distance visual acuity (CDVA were 0.19±0.12 and 0.14±0.10, respectively. Postoperative UDVA of 20/40 or better was achieved in 92.6% of eyes. Mean refractive cylinder decreased significantly from −3.73±1.96 to −1.42±0.88 D (p<0.001, while keratometric cylinder did not change significantly (p=0.44. Mean absolute IOL rotation was 1.1±2.4°, with values of more than 5° in only 2 eyes (6.9%. Mean patient satisfaction score was 9.70±0.46, using a scale from 0 (not at all satisfied to 10 (very satisfied. No postoperative optical/visual disturbances were reported. Conclusion. Cataract surgery with implantation of the Tecnis toric IOL is an effective method of refractive correction in eyes with corneal astigmatism due to the good IOL positional stability, providing high levels of patient’s satisfaction.

  18. Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens

    Directory of Open Access Journals (Sweden)

    Talita Shimoda

    2014-04-01

    Full Text Available Purpose: To assess the postoperative outcomes of a novel toric multifocal in traocular lens (IOL in patients with cataract and corneal astigmatism. Methods: This prospective nonrandomized study included patients with cataract, corneal astigmatism, and a motivation for spectacle independence. In all patients, a Rayner M-flex® T toric IOL was implanted in the capsular bag. Three months after surgery, the distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity were evaluated. A patient satisfaction and visual phenomena questionnaire was administered to all patients. Results: Thirty-four eyes of 18 patients were included in this study. Three months after surgery, the mean corrected distance visual acuity (logMAR was 0.00 ± 0.08 at 6 m, 0.20 ± 0.09 at 70 cm, and 0.08 ± 0.11 at 40 cm. Uncorrected distance vision acuity was 20/40 or better in 100% eyes. The preoperative mean refractive cylinder (RC was -2.19 (SD: ± 0.53. After a 3-month follow-up, the average RC was -0.44 D (SD: ± 0.27; p<0.001. Contrast sensitivity levels were high. At the last follow-up, 87.5% patients were spectacle-independent for near, intermediate, and distance vision, and approximately 44% patients reported halos and glare. Conclusion: Toric multifocal IOL implantation in patients with cataract and corneal astigmatism using the Rayner M-flex® T toric IOL was a simple, safe, and accurate option. This technology provides surgeons with a feasible option for meeting patient expectations of an enhanced lifestyle resulting from decreased spectacle dependence.

  19. Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial.

    Science.gov (United States)

    Ang, Marcus; Tan, Donald; Mehta, Jodhbir S

    2012-05-31

    Small incision lenticule extraction or SMILE is a novel form of 'flapless' corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. This novel

  20. The Distribution of Chromosomal Aberrations in Human Cells Predicted by a Generalized Time-Dependent Model of Radiation-Induced Formation of Aberrations

    Science.gov (United States)

    Ponomarev, Artem L.; George, K.; Cucinotta, F. A.

    2011-01-01

    New experimental data show how chromosomal aberrations for low- and high-LET radiation are dependent on DSB repair deficiencies in wild-type, AT and NBS cells. We simulated the development of chromosomal aberrations in these cells lines in a stochastic track-structure-dependent model, in which different cells have different kinetics of DSB repair. We updated a previously formulated model of chromosomal aberrations, which was based on a stochastic Monte Carlo approach, to consider the time-dependence of DSB rejoining. The previous version of the model had an assumption that all DSBs would rejoin, and therefore we called it a time-independent model. The chromosomal-aberrations model takes into account the DNA and track structure for low- and high-LET radiations, and provides an explanation and prediction of the statistics of rare and more complex aberrations. We compared the program-simulated kinetics of DSB rejoining to the experimentally-derived bimodal exponential curves of the DSB kinetics. We scored the formation of translocations, dicentrics, acentric and centric rings, deletions, and inversions. The fraction of DSBs participating in aberrations was studied in relation to the rejoining time. Comparisons of simulated dose dependence for simple aberrations to the experimental dose-dependence for HF19, AT and NBS cells will be made.

  1. The refractive index of relic gravitons

    CERN Document Server

    Giovannini, Massimo

    2016-01-01

    The dynamical evolution of the refractive index of the tensor modes of the geometry produces a specific class of power spectra characterized by a blue (i.e. slightly increasing) slope which is directly determined by the competition of the slow-roll parameter and of the rate of variation of the refractive index. Throughout the conventional stages of the inflationary and post-inflationary evolution, the microwave background anisotropies measurements, the pulsar timing limits and the big-bang nucleosythesis constraints set stringent bounds on the refractive index and on its rate of variation. Within the physically allowed region of the parameter space the cosmic background of relic gravitons leads to a potentially large signal for the ground based detectors (in their advanced version) and for the proposed space-borne interferometers. Conversely, the lack of direct detection of the signal will set a qualitatively new bound on the dynamical variation of the refractive index.

  2. Genomic portrait of resectable hepatocellular carcinomas: implications of RB1 and FGF19 aberrations for patient stratification.

    Science.gov (United States)

    Ahn, Sung-Min; Jang, Se Jin; Shim, Ju Hyun; Kim, Deokhoon; Hong, Seung-Mo; Sung, Chang Ohk; Baek, Daehyun; Haq, Farhan; Ansari, Adnan Ahmad; Lee, Sun Young; Chun, Sung-Min; Choi, Seongmin; Choi, Hyun-Jeung; Kim, Jongkyu; Kim, Sukjun; Hwang, Shin; Lee, Young-Joo; Lee, Jong-Eun; Jung, Wang-Rim; Jang, Hye Yoon; Yang, Eunho; Sung, Wing-Kin; Lee, Nikki P; Mao, Mao; Lee, Charles; Zucman-Rossi, Jessica; Yu, Eunsil; Lee, Han Chu; Kong, Gu

    2014-12-01

    Hepatic resection is the most curative treatment option for early-stage hepatocellular carcinoma, but is associated with a high recurrence rate, which exceeds 50% at 5 years after surgery. Understanding the genetic basis of hepatocellular carcinoma at surgically curable stages may enable the identification of new molecular biomarkers that accurately identify patients in need of additional early therapeutic interventions. Whole exome sequencing and copy number analysis was performed on 231 hepatocellular carcinomas (72% with hepatitis B viral infection) that were classified as early-stage hepatocellular carcinomas, candidates for surgical resection. Recurrent mutations were validated by Sanger sequencing. Unsupervised genomic analyses identified an association between specific genetic aberrations and postoperative clinical outcomes. Recurrent somatic mutations were identified in nine genes, including TP53, CTNNB1, AXIN1, RPS6KA3, and RB1. Recurrent homozygous deletions in FAM123A, RB1, and CDKN2A, and high-copy amplifications in MYC, RSPO2, CCND1, and FGF19 were detected. Pathway analyses of these genes revealed aberrations in the p53, Wnt, PIK3/Ras, cell cycle, and chromatin remodeling pathways. RB1 mutations were significantly associated with cancer-specific and recurrence-free survival after resection (multivariate P = 0.038 and P = 0.012, respectively). FGF19 amplifications, known to activate Wnt signaling, were mutually exclusive with CTNNB1 and AXIN1 mutations, and significantly associated with cirrhosis (P = 0.017). RB1 mutations can be used as a prognostic molecular biomarker for resectable hepatocellular carcinoma. Further study is required to investigate the potential role of FGF19 amplification in driving hepatocarcinogenesis in patients with liver cirrhosis and to investigate the potential of anti-FGF19 treatment in these patients. © 2014 by the American Association for the Study of Liver Diseases.

  3. Peripheral refractive correction and automated perimetric profiles.

    Science.gov (United States)

    Wild, J M; Wood, J M; Crews, S J

    1988-06-01

    The effect of peripheral refractive error correction on the automated perimetric sensitivity profile was investigated on a sample of 10 clinically normal, experienced observers. Peripheral refractive error was determined at eccentricities of 0 degree, 20 degrees and 40 degrees along the temporal meridian of the right eye using the Canon Autoref R-1, an infra-red automated refractor, under the parametric conditions of the Octopus automated perimeter. Perimetric sensitivity was then undertaken at these eccentricities (stimulus sizes 0 and III) with and without the appropriate peripheral refractive correction using the Octopus 201 automated perimeter. Within the measurement limits of the experimental procedures employed, perimetric sensitivity was not influenced by peripheral refractive correction.

  4. Initial resident refractive surgical experience: outcomes of PRK and LASIK for myopia.

    Science.gov (United States)

    Wagoner, Michael D; Wickard, Joseph C; Wandling, George R; Milder, Lisa C; Rauen, Matthew P; Kitzmann, Anna S; Sutphin, John E; Goins, Kenneth M

    2011-03-01

    To evaluate and compare the outcome of initial resident surgical experience with photorefractive keratectomy (PRK) and LASIK. Retrospective review of all cases performed with the VISX Star S4 platform (Abbott Medical Optics) between July 1, 2003 and June 30, 2007. Inclusion criteria were spherical equivalent of -0.50 to -10.00 diopters (D), refractive astigmatic error of ≤3.00 D, intention to provide full distance correction, and minimum 3-month postoperative follow-up after initial ablation or retreatment (if performed). A total of 153 cases performed by 20 different residents met the inclusion criteria; 38 eyes underwent PRK and 115 eyes had LASIK. After initial treatment, mean Snellen uncorrected distance visual acuity (UDVA) after PRK was 20/17.3 and after LASIK was 20/19.5. Photorefractive keratectomy was associated with a significantly better approximation between preoperative corrected distance visual acuity (CDVA) and postoperative UDVA (ΔlogMAR 0.009 vs 0.091; P=.004) and a greater percentage of eyes that achieved UDVA of 20/20 or better (94.7% vs 78.3%; P=.02) or 20/30 or better (100% vs 87.8%; P=.02). There was a higher prevalence of retreatment in eyes that underwent LASIK (7.0% vs 0%; P=.20). One (0.9%) eye lost 2 lines of CDVA after LASIK. Supervised refractive surgery residents can achieve excellent visual outcomes in patients operated during their initial refractive experience. Photorefractive keratectomy was associated with better visual outcome than LASIK. Copyright 2011, SLACK Incorporated.

  5. Chromosome aberrations in pesticide-exposed greenhouse workers

    DEFF Research Database (Denmark)

    Lander, B F; Knudsen, Lisbeth E.; Gamborg, M O

    2000-01-01

    OBJECTIVES: The aim of this study was to investigate the possibility of subtoxic exposure to pesticides causing chromosome aberrations in greenhouse workers. METHODS: In a cross-sectional and prospective study design chromosome aberration frequencies in cultured lymphocytes were examined for 116...... greenhouse workers exposed to a complex mixture of almost 50 insecticides, fungicides, and growth regulators and also for 29 nonsmoking, nonpesticide-exposed referents. RESULTS: The preseason frequencies of chromosome aberrations were slightly but not statistically significantly elevated for the greenhouse...... workers when they were compared with the referents. After a summer season of pesticide spraying in the greenhouses, the total frequencies of cells with chromosome aberrations were significantly higher than in the preseason samples (P=0.02) and also higher than for the referents (P=0.05). This finding...

  6. Reflective and refractive objects for mixed reality.

    Science.gov (United States)

    Knecht, Martin; Traxler, Christoph; Winklhofer, Christoph; Wimmer, Michael

    2013-04-01

    In this paper, we present a novel rendering method which integrates reflective or refractive objects into a differential instant radiosity (DIR) framework usable for mixed-reality (MR) applications. This kind of objects are very special from the light interaction point of view, as they reflect and refract incident rays. Therefore they may cause high-frequency lighting effects known as caustics. Using instant-radiosity (IR) methods to approximate these high-frequency lighting effects would require a large amount of virtual point lights (VPLs) and is therefore not desirable due to real-time constraints. Instead, our approach combines differential instant radiosity with three other methods. One method handles more accurate reflections compared to simple cubemaps by using impostors. Another method is able to calculate two refractions in real-time, and the third method uses small quads to create caustic effects. Our proposed method replaces parts in light paths that belong to reflective or refractive objects using these three methods and thus tightly integrates into DIR. In contrast to previous methods which introduce reflective or refractive objects into MR scenarios, our method produces caustics that also emit additional indirect light. The method runs at real-time frame rates, and the results show that reflective and refractive objects with caustics improve the overall impression for MR scenarios.

  7. Label-free monitoring of diffusion in microfluidics

    DEFF Research Database (Denmark)

    Sørensen, Kristian Tølbøl; Kristensen, Anders

    2017-01-01

    Label-free, real-time detection of concentration gradients is demonstrated in a microfluidic H-filter, using an integrated photonic crystal slab sensor to monitor sample refractive index with spatial resolution. The recorded diffusion profiles reveal root-mean-square diffusion lengths for non...

  8. Comparison of single-step reverse transepithelial all-surface laser ablation (ASLA to alcohol-assisted photorefractive keratectomy

    Directory of Open Access Journals (Sweden)

    Aslanides IM

    2012-06-01

    Full Text Available Ioannis M Aslanides,1 Sara Padroni,1 Samuel Arba Mosquera,2 Antonis Ioannides,1 Achyut Mukherjee11Emmetropia Mediterranean Eye Institute, Heraklion, Crete, Greece; 2Schwind eye-tech-solutions GmbH, Kleinostheim, GermanyPurpose: To evaluate postoperative pain, corneal epithelial healing, development of corneal haze, refractive outcomes, and corneal aberrations in a novel one-step, modified transepithelial photorefractive keratectomy (PRK, termed All-surface laser ablation (ASLA, compared to conventional, alcohol-assisted PRK.Materials and methods: Sixty eyes of 30 myopic patients were prospectively recruited to a randomized fellow eye study. Patients underwent conventional alcohol-assisted PRK in one eye (control group and ASLA-modified transepithelial PRK in the other (30 eyes in each treatment arm. Primary endpoints were postoperative pain and haze scores at 1 day, 3 days, 1 week, and 1, 3, 6, and 12 months. Secondary endpoints included visual acuity at 1, 3, 6, and 12 months, corneal aberrations at 3, 6, and 12 months, and early and late onset haze. Refractive predictability, safety, and efficacy of the two methods were considered.Results: The average age of the cohort was 29 years (standard deviation [SD]: 9; range: 18–46, and the average spherical equivalent refractive error was -4.18 diopters (SD: 1.9. At 3 days after surgery, the average pain score was 64% lower in the ASLA group (P < 0.0005. At this point, 96% of ASLA eyes had no epithelial defect, whereas 43% in the alcohol-assisted group did not achieve complete epithelial healing, and required replacement of bandage contact lens. The haze level was consistently lower in the ASLA group at all time points from 1 to 6 months.Conclusion: This study shows that the ASLA technique may have a future role in refractive surgery, due to the fact that it offers faster epithelial healing, lower pain scores, and significantly less haze formation.Keywords: cornea, ASLA, PRK, alcohol

  9. Supersonic Fe beam source for chromatic aberration-free laser focusing of atoms

    CERN Document Server

    Bosch, R C M; Van der Straten, P; Leeuwen, K A H

    2002-01-01

    A monochromatic Fe beam is generated by heated supersonic expansion of argon seeded with Fe vapor. At a nozzle temperature of 1930 K and 800 torr argon inlet pressure the Fe beam has an axial velocity spread of 8% and intensity of 3 x 10 sup 1 sup 5 s sup - sup 1 sr sup - sup 1 , corresponding to a deposition rate of 10 nm/h at 150 mm from the nozzle. The two-chamber alumina crucibles are chemically stable for liquid Fe. With 400 mm sup 3 Fe we have operated for more than 200 hours without reloading. The power consumption at 1930 K is 750 W. Temperature stability at constant power (without feedback) is better than 30 K. The source is intended for deposition of nano-structures by laser focusing of the Fe beam. The small axial velocity spread virtually eliminates the increase in focal spot size due to chromatic aberration. (authors)

  10. A randomized clinical evaluation of the safety of Systane® Lubricant Eye Drops for the relief of dry eye symptoms following LASIK refractive surgery

    Directory of Open Access Journals (Sweden)

    Daniel Durrie

    2008-12-01

    Full Text Available Daniel Durrie, Jason StahlDurrie Vision, Overland Park, Kansas, USAPurpose: To evaluate the safety of Systane® Lubricant Eye Drops in relieving the symptoms of dry eye following laser-assisted in situ keratomileusis (LASIK surgery.Methods: This was a randomized, double-masked, single-center, placebo-controlled, contralateral eye study of 30 patients undergoing LASIK surgery. The mean age of patients was 42.4 ± 10.7 years, and the mean spherical equivalent was −3.29 (range, +1.75 to −7.38. Patients’ right and left eyes were randomized to receive either Systane® or placebo – a preserved, thimerosal-free saline solution – beginning from the day of surgery and ending 30 days following surgery. Outcome measures included tear film break up time (TFBUT, visual acuity, degree of corneal and conjunctival staining, and treatment-related adverse events.Results: Preoperatively, placebo-treated eyes had statistically significantly higher sum corneal staining score than Systane®-treated eyes (p = 0.0464; however, the difference was clinically insignificant (p = 0.27. Two weeks post operatively, the average TFBUT in the Systane®-treated eyes was 1.23 seconds longer than that of the placebo-treated eyes (p = 0.028. All other evaluated variables were comparable between the two treatments. No adverse events were reported in the study.Conclusion: Systane® Lubricant Eye Drops are safe for use following LASIK surgery to relieve the discomfort symptoms of dry eye associated with the procedure.Keywords: Systane®, safety, dry eye, LASIK

  11. Parsimonious wave-equation travel-time inversion for refraction waves

    KAUST Repository

    Fu, Lei

    2017-02-14

    We present a parsimonious wave-equation travel-time inversion technique for refraction waves. A dense virtual refraction dataset can be generated from just two reciprocal shot gathers for the sources at the endpoints of the survey line, with N geophones evenly deployed along the line. These two reciprocal shots contain approximately 2N refraction travel times, which can be spawned into O(N2) refraction travel times by an interferometric transformation. Then, these virtual refraction travel times are used with a source wavelet to create N virtual refraction shot gathers, which are the input data for wave-equation travel-time inversion. Numerical results show that the parsimonious wave-equation travel-time tomogram has about the same accuracy as the tomogram computed by standard wave-equation travel-time inversion. The most significant benefit is that a reciprocal survey is far less time consuming than the standard refraction survey where a source is excited at each geophone location.

  12. Image transfer with spatial coherence for aberration corrected transmission electron microscopes

    International Nuclear Information System (INIS)

    Hosokawa, Fumio; Sawada, Hidetaka; Shinkawa, Takao; Sannomiya, Takumi

    2016-01-01

    The formula of spatial coherence involving an aberration up to six-fold astigmatism is derived for aberration-corrected transmission electron microscopy. Transfer functions for linear imaging are calculated using the newly derived formula with several residual aberrations. Depending on the symmetry and origin of an aberration, the calculated transfer function shows characteristic symmetries. The aberrations that originate from the field’s components, having uniformity along the z direction, namely, the n-fold astigmatism, show rotational symmetric damping of the coherence. The aberrations that originate from the field’s derivatives with respect to z, such as coma, star, and three lobe, show non-rotational symmetric damping. It is confirmed that the odd-symmetric wave aberrations have influences on the attenuation of an image via spatial coherence. Examples of image simulations of haemoglobin and Si [211] are shown by using the spatial coherence for an aberration-corrected electron microscope. - Highlights: • The formula of partial coherence for aberration corrected TEM is derived. • Transfer functions are calculated with several residual aberrations. • The calculated transfer function shows the characteristic damping. • The odd-symmetric wave aberrations can cause the attenuation of image via coherence. • The examples of aberration corrected TEM image simulations are shown.

  13. Image transfer with spatial coherence for aberration corrected transmission electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Fumio, E-mail: hosokawa@bio-net.co.jp [BioNet Ltd., 2-3-28 Nishikityo, Tachikwa, Tokyo (Japan); Tokyo Institute of Technology, 4259 Nagatsuta, Midoriku, Yokohama 226-8503 (Japan); Sawada, Hidetaka [JEOL (UK) Ltd., JEOL House, Silver Court, Watchmead, Welwyn Garden City, Herts AL7 1LT (United Kingdom); Shinkawa, Takao [BioNet Ltd., 2-3-28 Nishikityo, Tachikwa, Tokyo (Japan); Sannomiya, Takumi [Tokyo Institute of Technology, 4259 Nagatsuta, Midoriku, Yokohama 226-8503 (Japan)

    2016-08-15

    The formula of spatial coherence involving an aberration up to six-fold astigmatism is derived for aberration-corrected transmission electron microscopy. Transfer functions for linear imaging are calculated using the newly derived formula with several residual aberrations. Depending on the symmetry and origin of an aberration, the calculated transfer function shows characteristic symmetries. The aberrations that originate from the field’s components, having uniformity along the z direction, namely, the n-fold astigmatism, show rotational symmetric damping of the coherence. The aberrations that originate from the field’s derivatives with respect to z, such as coma, star, and three lobe, show non-rotational symmetric damping. It is confirmed that the odd-symmetric wave aberrations have influences on the attenuation of an image via spatial coherence. Examples of image simulations of haemoglobin and Si [211] are shown by using the spatial coherence for an aberration-corrected electron microscope. - Highlights: • The formula of partial coherence for aberration corrected TEM is derived. • Transfer functions are calculated with several residual aberrations. • The calculated transfer function shows the characteristic damping. • The odd-symmetric wave aberrations can cause the attenuation of image via coherence. • The examples of aberration corrected TEM image simulations are shown.

  14. Microstructured optical fiber refractive index sensor

    DEFF Research Database (Denmark)

    Town, Graham E.; McCosker, Ravi; Yuan, Scott Wu

    2010-01-01

    We describe a dual-core microstructured optical fiber designed for refractive index sensing of fluids. We show that by using the exponential dependence of intercore coupling on analyte refractive index, both large range and high sensitivity can be achieved in the one device. We also show...

  15. Effect of aberration of light in X-ray free electron lasers

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2015-11-01

    We discuss the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick. Particle tracking shows that the electron beam direction changes after the kick, while the orientation of the microbunching wavefront stays unvaried. Therefore, electrons motion and wavefront normal have different directions. Coherent radiation emission in a downstream undulator is expected to be dramatically suppressed as soon as the kick angle becomes larger than the divergence of the output radiation. In fact, according to conventional treatments, coherent radiation is emitted along the normal to the microbunching wavefront. Here we show that kinematics predicts a surprising effect. Namely, a description of coherent undulator radiation in the laboratory frame yields the radical notion that, due light aberration, strong coherent radiation is produced along the direction of the kick. We hold a recent FEL study made at the LCLS as a direct experimental evidence that coherent undulator radiation can be kicked by an angle of about five times the rms radiation divergence without suppression. We put forward our kinematical description of this experiment.

  16. Effect of aberrations in human eye on contrast sensitivity function

    Science.gov (United States)

    Quan, Wei; Wang, Feng-lin; Wang, Zhao-qi

    2011-06-01

    The quantitative analysis of the effect of aberrations in human eye on vision has important clinical value in the correction of aberrations. The wave-front aberrations of human eyes were measured with the Hartmann-Shack wave-front sensor and modulation transfer function (MTF) was computed from the wave-front aberrations. Contrast sensitivity function (CSF) was obtained from MTF and the retinal aerial image modulation (AIM). It is shown that the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations deteriorate contrast sensitivity function. When the 2nd, 3rd, 4th, 5th, 6th Zernike aberrations are corrected high contrast sensitivity function can be obtained.

  17. The experimental set-valued index of refraction of dielectric and anelastic media

    Directory of Open Access Journals (Sweden)

    M. Caputo

    2000-06-01

    Full Text Available The dielectric parameter, in the generalised Debye form, of all studied substances (Cole and Cole, 1941 contains a rational power of the imaginary frequency which implies that the index of refraction is a multivalued function of the frequency; the same property, concerning the stress strain relation, also applies to anelastic media (Bagley and Torvik, 1983a,b. The multivalued index of refraction implies then that the free modes of dielectric and anelastic media are split into a number of modes which depend on the exponent of the imaginary frequency. In order to estimate if it is possible to observe this splitting, this note computes the parameters appearing in the generalised Debye form of the dielectric parameters of many substances and also the complex anelastic parameter of an anelastic medium. The analysis of the data indicates that, depending on the accuracy of the experimental data, with few exceptions, the splitting is observable.

  18. Chromosome aberration analysis for biological dosimetry: a review

    International Nuclear Information System (INIS)

    Paul, S.F.D.; Venkatachalam, P.; Jeevanram, R.K.

    1996-01-01

    Among various biological dosimetry techniques, dicentric chromosome aberration method appears to be the method of choice in analysing accidental radiation exposure in most of the laboratories. The major advantage of this method is its sensitivity as the number of dicentric chromosomes present in control population is too small and more importantly radiation induces mainly dicentric chromosome aberration among unstable aberration. This report brings out the historical development of various cytogenetic methods, the basic structure of DNA, chromosomes and different forms of chromosome aberrations. It also highlights the construction of dose-response curve for dicentric chromosome and its use in the estimation of radiation dose. (author)

  19. The Art of Optical Aberrations

    Science.gov (United States)

    Wylde, Clarissa Eileen Kenney

    Art and optics are inseparable. Though seemingly opposite disciplines, the combination of art and optics has significantly impacted both culture and science as they are now known. As history has run its course, in the sciences, arts, and their fruitful combinations, optical aberrations have proved to be a problematic hindrance to progress. In an effort to eradicate aberrations the simple beauty of these aberrational forms has been labeled as undesirable and discarded. Here, rather than approach aberrations as erroneous, these beautiful forms are elevated to be the photographic subject in a new body of work, On the Bright Side. Though many recording methods could be utilized, this work was composed on classic, medium-format, photographic film using white-light, Michelson interferometry. The resulting images are both a representation of the true light rays that interacted on the distorted mirror surfaces (data) and the artist's compositional eye for what parts of the interferogram are chosen and displayed. A detailed description of the captivating interdisciplinary procedure is documented and presented alongside the final artwork, CCD digital reference images, and deformable mirror contour maps. This alluring marriage between the arts and sciences opens up a heretofore minimally explored aspect of the inextricable art-optics connection. It additionally provides a fascinating new conversation on the importance of light and optics in photographic composition.

  20. Photonic Crystal Biosensor Chip for Label-Free Detection of Bacteria

    DEFF Research Database (Denmark)

    Kristensen, Martin; Krüger, Asger Christian; Groothoff, Nathaniel

    Narrow polarization-mixing resonances in planar photonic crystals are studied as candidate components for label-free refractive index sensors for detecting bacteria causing sepsis through the identification of DNA strands....

  1. The refractive index of human hemoglobin in the visible range

    International Nuclear Information System (INIS)

    Zhernovaya, O; Tuchin, V; Sydoruk, O; Douplik, A

    2011-01-01

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l -1 . This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l -1 . The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  2. Negative Refraction Angular Characterization in One-Dimensional Photonic Crystals

    OpenAIRE

    Lugo, Jesus Eduardo; Doti, Rafael; Faubert, Jocelyn

    2011-01-01

    Background Photonic crystals are artificial structures that have periodic dielectric components with different refractive indices. Under certain conditions, they abnormally refract the light, a phenomenon called negative refraction. Here we experimentally characterize negative refraction in a one dimensional photonic crystal structure; near the low frequency edge of the fourth photonic bandgap. We compare the experimental results with current theory and a theory based on the group velocity de...

  3. Phase sensitive diffraction sensor for high sensitivity refractive index measurement

    Science.gov (United States)

    Kumawat, Nityanand; Varma, Manoj; Kumar, Sunil

    2018-02-01

    In this study a diffraction based sensor has been developed for bio molecular sensing applications and performing assays in real time. A diffraction grating fabricated on a glass substrate produced diffraction patterns both in transmission and reflection when illuminated by a laser diode. We used zeroth order I(0,0) as reference and first order I(0,1) as signal channel and conducted ratiometric measurements that reduced noise by more than 50 times. The ratiometric approach resulted in a very simple instrumentation with very high sensitivity. In the past, we have shown refractive index measurements both for bulk and surface adsorption using the diffractive self-referencing approach. In the current work we extend the same concept to higher diffraction orders. We have considered order I(0,1) and I(1,1) and performed ratiometric measurements I(0,1)/I(1,1) to eliminate the common mode fluctuations. Since orders I(0,1) and I(1,1) behaved opposite to each other, the resulting ratio signal amplitude increased more than twice compared to our previous results. As a proof of concept we used different salt concentrations in DI water. Increased signal amplitude and improved fluid injection system resulted in more than 4 times improvement in detection limit, giving limit of detection 1.3×10-7 refractive index unit (RIU) compared to our previous results. The improved refractive index sensitivity will help significantly for high sensitivity label free bio sensing application in a very cost-effective and simple experimental set-up.

  4. Aberration design of zoom lens systems using thick lens modules.

    Science.gov (United States)

    Zhang, Jinkai; Chen, Xiaobo; Xi, Juntong; Wu, Zhuoqi

    2014-12-20

    A systematic approach for the aberration design of a zoom lens system using a thick lens module is presented. Each component is treated as a thick lens module at the beginning of the design. A thick lens module refers to a thick lens component with a real lens structure, like lens materials, lens curvatures, lens thicknesses, and lens interval distances. All nine third-order aberrations of a thick lens component are considered during the design. The relationship of component aberrations in different zoom positions can be approximated from the aberration shift. After minimizing the aberrations of the zoom lens system, the nine third-order aberrations of every lens component can be determined. Then the thick lens structure of every lens component can be determined after optimization according to their first-order properties and third-order aberration targets. After a third optimization for minimum practical third-order aberrations of a zoom lens system, the aberration design using the thick lens module is complete, which provides a practical zoom lens system with thick lens structures. A double-sided telecentric zoom lens system is designed using the thick lens module in this paper, which shows that this method is practical for zoom lens design.

  5. Experimental Determination of Refractive Index of Gas Hydrates

    DEFF Research Database (Denmark)

    Bylov, Martin; Rasmussen, Peter

    1997-01-01

    . For methane hydrate (structure I) the refractive index was found to be 1.346 and for natural gas hydrate (structure II) it was found to be 1.350. The measurements further suggest that the gas hydrate growth rate increases if the water has formed hydrates before. The induction time, on the other hand, seems......The refractive indexes of methane hydrate and natural gas hydrate have been experimentally determined. The refractive indexes were determined in an indirect manner making use of the fact that two non-absorbing materials will have the same refractive index if they cannot be distinguished visually...

  6. Characterizing conical refraction optical tweezers

    Science.gov (United States)

    McDonald, C.; McDougall, C.; Rafailov, E.; McGloin, D.

    2014-12-01

    Conical refraction occurs when a beam of light travels through an appropriately cut biaxial crystal. By focussing the conically refracted beam through a high numerical aperture microscope objective, conical refraction optical tweezers can be created, allowing for particle manipulation in both Raman spots and in the Lloyd/Poggendorff rings. We present a thorough quantification of the trapping properties of such a beam, focussing on the trap stiffness and how this varies with trap power and trapped particle location. We show that the lower Raman spot can be thought of as a single-beam optical gradient force trap, while radiation pressure dominates in the upper Raman spot, leading to optical levitation rather than trapping. Particles in the Lloyd/Poggendorff rings experience a lower trap stiffness than particles in the lower Raman spot but benefit from rotational control.

  7. Refractive Errors Affect the Vividness of Visual Mental Images

    Science.gov (United States)

    Palermo, Liana; Nori, Raffaella; Piccardi, Laura; Zeri, Fabrizio; Babino, Antonio; Giusberti, Fiorella; Guariglia, Cecilia

    2013-01-01

    The hypothesis that visual perception and mental imagery are equivalent has never been explored in individuals with vision defects not preventing the visual perception of the world, such as refractive errors. Refractive error (i.e., myopia, hyperopia or astigmatism) is a condition where the refracting system of the eye fails to focus objects sharply on the retina. As a consequence refractive errors cause blurred vision. We subdivided 84 individuals according to their spherical equivalent refraction into Emmetropes (control individuals without refractive errors) and Ametropes (individuals with refractive errors). Participants performed a vividness task and completed a questionnaire that explored their cognitive style of thinking before their vision was checked by an ophthalmologist. Although results showed that Ametropes had less vivid mental images than Emmetropes this did not affect the development of their cognitive style of thinking; in fact, Ametropes were able to use both verbal and visual strategies to acquire and retrieve information. Present data are consistent with the hypothesis of equivalence between imagery and perception. PMID:23755186

  8. Long-term outcomes of limbal relaxing incisions during cataract surgery: aberrometric analysis

    Directory of Open Access Journals (Sweden)

    Monaco G

    2015-08-01

    Full Text Available Gaspare Monaco, Antonio ScialdoneDepartment of Ophthalmology, Ospedale Fatebenefratelli e Oftalmico, Milan, ItalyPurpose: To compare the final changes in corneal wavefront aberration by limbal relaxing incisions (LRIs after cataract surgery.Methods: This prospective cumulative interventional nonrandomized case study included cataract and astigmatic patients undergoing LRIs and phaco with intraocular lens implantation. LRIs were planned using Donnenfeld nomogram. The root mean square of corneal wave aberration for total Z(n,i(1≤n≤8, astigmatism Z(2,±1, coma Z(3–5–7,±1, trefoil Z(3–5–7,±2, spherical Z(4–6–8,0, and higher-order aberration (HOA Z(3≤n≤8 was examined before and 3 years after surgery (optical path difference-Scan II [OPD-Scan II]. Uncorrected distance visual acuity and best-corrected distance visual acuity (CDVA for distance, keratometric cylinder, and variations in average corneal power were also analyzed.Results: Sixty-four eyes of 48 patients were included in the study. Age ranged from 42 to 92 years (70.6±8.4 years. After LRIs, uncorrected distance visual acuity and best-corrected distance visual acuity improved statistically (P<0.01. The keratometric cylinder value decreased by 40.1%, but analysis of KP90 and KP135 polar values did not show any decrease that could be statistically confirmed (P=0.22 and P=0.24. No significant changes were detected in root mean square of total (P=0.61 and HOAs (P=0.13 aberrations. LRIs did not induce alteration in central corneal power confirming a 1:1 coupling ratio.Conclusion: LRIs determined a nonsignificant alteration of corneal HOA. Therefore, LRIs can be still considered a qualitatively viable mean in those cases where toric intraocular lenses are contraindicated or not available. Yet, the authors raise the question of nonpersonalized nomograms, as in the present study, LRIs did not reach the preset target cylinder. Keywords: astigmatism, ocular wavefront, intraocular

  9. Third-order monochromatic aberrations via Fermat's principle

    International Nuclear Information System (INIS)

    Marasco, A.; Romano, A.

    2006-01-01

    By Fermat's principle and particular optical paths, which are not rays, a new aberration function is introduced. This function allows to derive, without resorting to the whole Hamiltonian formalism, the third-order geometrical aberrations of an optical system with a symmetry of revolution

  10. Simultaneous bilateral cataract surgery: economic analysis; Helsinki Simultaneous Bilateral Cataract Surgery Study Report 2.

    Science.gov (United States)

    Leivo, Tiina; Sarikkola, Anna-Ulrika; Uusitalo, Risto J; Hellstedt, Timo; Ess, Sirje-Linda; Kivelä, Tero

    2011-06-01

    To present an economic-analysis comparison of simultaneous and sequential bilateral cataract surgery. Helsinki University Eye Hospital, Helsinki, Finland. Economic analysis. Effects were estimated from data in a study in which patients were randomized to have bilateral cataract surgery on the same day (study group) or sequentially (control group). The main clinical outcomes were corrected distance visual acuity, refraction, complications, Visual Function Index-7 (VF-7) scores, and patient-rated satisfaction with vision. Health-care costs of surgeries and preoperative and postoperative visits were estimated, including the cost of staff, equipment, material, floor space, overhead, and complications. The data were obtained from staff measurements, questionnaires, internal hospital records, and accountancy. Non-health-care costs of travel, home care, and time were estimated based on questionnaires from a random subset of patients. The main economic outcome measures were cost per VF-7 score unit change and cost per patient in simultaneous versus sequential surgery. The study comprised 520 patients (241 patients included non-health-care and time cost analyses). Surgical outcomes and patient satisfaction were similar in both groups. Simultaneous cataract surgery saved 449 Euros (€) per patient in health-care costs and €739 when travel and paid home-care costs were included. The savings added up to €849 per patient when the cost of lost working time was included. Compared with sequential bilateral cataract surgery, simultaneous bilateral cataract surgery provided comparable clinical outcomes with substantial savings in health-care and non-health-care-related costs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Catadioptric aberration correction in cathode lens microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tromp, R.M. [IBM T.J. Watson Research Center, PO Box 218, Yorktown Heights, NY 10598 (United States); Kamerlingh Onnes Laboratory, Leiden Institute of Physics, Niels Bohrweg 2, 2333 CA Leiden (Netherlands)

    2015-04-15

    In this paper I briefly review the use of electrostatic electron mirrors to correct the aberrations of the cathode lens objective lens in low energy electron microscope (LEEM) and photo electron emission microscope (PEEM) instruments. These catadioptric systems, combining electrostatic lens elements with a reflecting mirror, offer a compact solution, allowing simultaneous and independent correction of both spherical and chromatic aberrations. A comparison with catadioptric systems in light optics informs our understanding of the working principles behind aberration correction with electron mirrors, and may point the way to further improvements in the latter. With additional developments in detector technology, 1 nm spatial resolution in LEEM appears to be within reach. - Highlights: • The use of electron mirrors for aberration correction in LEEM/PEEM is reviewed. • A comparison is made with similar systems in light optics. • Conditions for 1 nm spatial resolution are discussed.

  12. Radiation-induced chromosome aberrations in the rat peripheral blood

    International Nuclear Information System (INIS)

    Ziemba-Zoltowska, B.; Bocian, E.; Radwan, I.; Rosiek, O.; Sablinski, J.

    1978-01-01

    Chromosome aberrations in rat lymphocytes of peripheral blood after X (in vitro and in vivo) and 3 H tritiated water (in vivo) irradiations were studied. The yield of chromosome aberrations after in vivo and in vitro exposure to X-rays was similar. The frequency of chromosome aberrations three weeks after exposure to X-rays and soon after irradiation was practically on the same level. The yield of chromosome aberrations determined three weeks after injection with tritiated water or X-rays exposure was similar. (author)

  13. Chromosomal aberrations in bone marrow of continuously irradiated rats

    Energy Technology Data Exchange (ETDEWEB)

    Chlebosky, O; Praslicka, M; Chlebovska, K [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Prirodovedecka Fakulta

    1975-01-01

    Research on chromosomal aberrations of the bone marrow in continuously irradiated rats showed that chromosomal aberrations are a highly sensitive indicator of radiation injury. An increase in the chromosomal aberration frequency was already found on the 5th day at daily doses of 0.5 R, i.e. a 12% increase at a total dose of 25 R. In the steady-state stage at daily doses of 0.5; 1; 2.5 R, the number of chromosomal aberrations stabilized at values of about 20%; at daily doses of 5 and 10 R at values of 30.=., at daily doses of 53 R at 45%, at a daily dose of 82.5 R, the number of chromosomal aberrations increased to 55%.

  14. Aberration-corrected STEM/TEM imaging at 15 kV

    International Nuclear Information System (INIS)

    Sasaki, Takeo; Sawada, Hidetaka; Hosokawa, Fumio; Sato, Yuta; Suenaga, Kazu

    2014-01-01

    The performance of aberration-corrected (scanning) transmission electron microscopy (S/TEM) at an accelerating voltage of 15 kV was evaluated in a low-voltage microscope equipped with a cold-field emission gun and a higher-order aberration corrector. Aberrations up to the fifth order were corrected by the aberration measurement and auto-correction system using the diffractogram tableau method in TEM and Ronchigram analysis in STEM. TEM observation of nanometer-sized particles demonstrated that aberrations up to an angle of 50 mrad were compensated. A TEM image of Si[110] exhibited lattice fringes with a spacing of 0.192 nm, and the power spectrum of the image showed spots corresponding to distances of 0.111 nm. An annular dark-field STEM image of Si[110] showed lattice fringes of (111) and (22¯0) planes corresponding to lattice distances of 0.314 nm and 0.192 nm, respectively. At an accelerating voltage of 15 kV, the developed low-voltage microscope achieved atomic-resolution imaging with a small chromatic aberration and a large uniform phase. - Highlights: • Aberration-corrected STEM/TEM imaging at 15 kV demonstrated lattice fringes of Si[110] single crystal with a spacing of 0.192 nm. • To achieve this performance at a lower accelerating voltage, uniform phase area over 50 mrad is mandatory in Ronchigram and Diffractogram tableau. • This means a higher-order aberration of six-fold astigmatism should be compensated. • In addition, decreasing the effect of chromatic aberration plays an important role for improving the performance of linear scattering component at 15 kV TEM

  15. Monitoring change in refractive index of cytosol of animal cells on affinity surface under osmotic stimulus for label-free measurement of viability.

    Science.gov (United States)

    Park, Jina; Jin, Sung Il; Kim, Hyung Min; Ahn, Junhyoung; Kim, Yeon-Gu; Lee, Eun Gyo; Kim, Min-Gon; Shin, Yong-Beom

    2015-02-15

    We demonstrated that a metal-clad waveguide (MCW)-based biosensor can be applied to label-free measurements of viability of adherent animal cells with osmotic stimulation in real time. After Chinese hamster ovary (CHO) and human embryonic kidney cell 293 (HEK293) cells were attached to a Concanavalin A (Con A)-modified sensor surface, the magnitudes of cell responses to non-isotonic stimulation were compared between live and dead cells. The live cells exhibited a change in the refractive index (RI) of the cytosol caused by a redistribution of water through the cell membrane, which was induced by the osmotic stimulus, but the dead cells did not. Moreover, the normalized change in the RI measured via the MCW sensor was linearly proportional to the viability of attached cells and the resolution in monitoring cell viability was about 0.079%. Therefore, the viability of attached animal cells can be measured without labels by observing the relative differences in the RI of cytosol in isotonic and non-isotonic buffers. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Topography-modified refraction (TMR): adjustment of treated cylinder amount and axis to the topography versus standard clinical refraction in myopic topography-guided LASIK.

    Science.gov (United States)

    Kanellopoulos, Anastasios John

    2016-01-01

    To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.

  17. Estimation of dose from chromosome aberration rate

    International Nuclear Information System (INIS)

    Li Deping

    1990-01-01

    The methods and skills of evaluating dose from correctly scored shromsome aberration rate are presented, and supplemented with corresponding BASIC computer code. The possibility and preventive measures of excessive probability of missing score of the aberrations in some of the current routine score methods are discussed. The use of dose-effect relationship with exposure time correction factor G in evaluating doses and their confidence intervals, dose estimation in mixed n-γ exposure, and identification of high by nonuniform acute exposure to low LET radiation and its dose estimation are discussed in more detail. The difference of estimated dose due to whether the interaction between subleisoms produced by n and γ have been taken into account is examined. In fitting the standard dose-aberration rate curve, proper weighing of experiment points and comparison with commonly accepted values are emphasised, and the coefficient of variation σ y √y of the aberration rate y as a function of dose and exposure time is given. In appendix I and II, the dose-aberration rate formula is derived from dual action theory, and the time variation of subleisom is illustrated and in appendix III, the estimation of dose from scores of two different types of aberrations (of other related score) is illustrated. Two computer codes are given in appendix IV, one is a simple code, the other a complete code, including the fitting of standard curve. the skills of using compressed data storage, and the production of simulated 'data ' for testing the curve fitting procedure are also given

  18. Evidence for subwavelength imaging with positive refraction

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Yun Gui [Temasek Laboratories, National University of Singapore, Singapore 119260 (Singapore); Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf [School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews KY16 9SS (United Kingdom); Ong, C K, E-mail: ulf@st-andrews.ac.uk [Centre for Superconducting and Magnetic Materials, Department of Physics, National University of Singapore, Singapore 117542 (Singapore)

    2011-03-15

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  19. Evidence for subwavelength imaging with positive refraction

    International Nuclear Information System (INIS)

    Ma, Yun Gui; Sahebdivan, Sahar; Tyc, Tomas; Leonhardt, Ulf; Ong, C K

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction.

  20. Aberration of a negative ion beam caused by space charge effect

    International Nuclear Information System (INIS)

    Miyamoto, K.; Wada, S.; Hatayama, A.

    2010-01-01

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  1. Aberration of a negative ion beam caused by space charge effect

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, K. [Naruto University of Education, 748 Nakashima, Takashima, Naruto-cho, Naruto-shi, Tokushima 772-8502 (Japan); Wada, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522 (Japan)

    2010-02-15

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  2. Aberration of a negative ion beam caused by space charge effect.

    Science.gov (United States)

    Miyamoto, K; Wada, S; Hatayama, A

    2010-02-01

    Aberrations are inevitable when the charged particle beams are extracted, accelerated, transmitted, and focused with electrostatic and magnetic fields. In this study, we investigate the aberration of a negative ion accelerator for a neutral beam injector theoretically, especially the spherical aberration caused by the negative ion beam expansion due to the space charge effect. The negative ion current density profiles with the spherical aberration are compared with those without the spherical aberration. It is found that the negative ion current density profiles in a log scale are tailed due to the spherical aberration.

  3. Phakic intraocular lenses for the treatment of refractive errors: an evidence-based analysis.

    Science.gov (United States)

    2009-01-01

    .6 per 10,000 people in Canada have low vision. The 2001 Participation and Activity Limitation Survey (PALS) found that 594,350 (2.5%) Canadians had "difficulty seeing ordinary newsprint or clearly seeing the face of someone from 4 m," and the Canadian National Institute for the Blind (CNIB) registry classified 105,000 (.35%) Canadians as visually disabled. PHAKIC INTRAOCULAR LENSES (PIOL): A phakic intraocular lens (pIOL) is a supplementary lens that is inserted into the anterior or posterior chamber of the eye to correct refractive errors (myopia, hyperopia, and astigmatism). Unlike in cataract surgery, the eye's natural crystalline lens is not removed when the pIOL is inserted, so the eye retains its accommodative ability. In Canada and the United States, iris-fixated (anterior chamber lenses that are anchored to the iris with a claw) and posterior chamber lenses are the only types of pIOLs that are licensed by Health Canada and the Food and Drug Administration, respectively. EVIDENCE-BASED ANALYSIS METHOD: RESEARCH QUESTIONS #ENTITYSTARTX00026; What are the effectiveness, cost-effectiveness, and safety of pIOLs for the treatment of myopia, hyperopia, and astigmatism?Do certain subgroups (e.g. high myopia and low vision) benefit more from pIOLs?How do pIOLs compare with alternative surgical treatment options (LASIK, PRK, and CLE)?Using appropriate keywords, a literature search was conducted up to January 2009. Systematic reviews, meta-analyses, randomized controlled trials, and observational studies with more than 20 eyes receiving pIOLs were eligible for inclusion. The primary outcomes of interest were uncorrected visual acuity (UCVA), predictability of manifest refraction spherical equivalent (MRSE), and adverse events. The GRADE approach was used to systematically and explicitly evaluate the quality of evidence. The search identified 1,131 citations published between January 1, 2003, and January 16, 2009. Including a health technology assessment (HTA) identified in

  4. Aberrant regeneration of the third cranial nerve.

    Science.gov (United States)

    Shrestha, U D; Adhikari, S

    2012-01-01

    Aberrant regeneration of the third cranial nerve is most commonly due to its damage by trauma. A ten-month old child presented with the history of a fall from a four-storey building. She developed traumatic third nerve palsy and eventually the clinical features of aberrant regeneration of the third cranial nerve. The adduction of the eye improved over time. She was advised for patching for the strabismic amblyopia as well. Traumatic third nerve palsy may result in aberrant regeneration of the third cranial nerve. In younger patients, motility of the eye in different gazes may improve over time. © NEPjOPH.

  5. Transverse correlation vanishing due to phase aberrations

    CSIR Research Space (South Africa)

    Godin, T

    2011-06-01

    Full Text Available of the effects of each aberration on the ratio Sp ?? / , the following condition are imposed: 0max3max2max1 )()()( ??????? === . (9) It is assumed that the phase aberration is set in the beam-waist plane of radius mmW 5.10 = . Arbitrarily, the value... of max? is fixed to twice the incident beam width, 0max 2W=? , where the intensity is only 0.03% of the on-axis value. In the following we will express the aberration 0? in number of equivalent wavelengths given by the ratio )2/(00 pi...

  6. Frequencies of chromosome aberration on radiation workers

    International Nuclear Information System (INIS)

    Yanti Lusiyanti; Zubaidah Alatas

    2016-01-01

    Radiation exposure of the body can cause damage to the genetic material in cells (cytogenetic) in the form of changes in the structure or chromosomal aberrations in peripheral blood lymphocytes. Chromosomal aberrations can be unstable as dicentric and ring chromosomes, and is stable as translocation. Dicentric chromosome is the gold standard biomarker due to radiation exposure, and chromosome translocation is a biomarker for retrospective biodosimetry. The aim of this studi is to conduct examination of chromosomal aberrations in the radiation worker to determine the potential damage of cell that may arise due to occupational radiation exposure. The examination have been carried out on blood samples from 55 radiation workers in the range of 5-30 year of service. Chromosome aberration frequency measurement starts with blood sampling, culturing, harvesting, slide preparations, and lymphocyte chromosome staining with Giemsa and painting with Fluorescence In Situ Hybridization (FISH) technique. The results showed that chromosomal translocations are not found in blood samples radiation workers and dicentric chromosomes found only on 2 blood samples of radiation workers with a frequency of 0.001/cell. The frequency of chromosomal aberrations in the blood cells such workers within normal limits and this means that the workers have been implemented a radiation safety aspects very well. (author)

  7. Seismic refraction survey of the ANS preferred site

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R.K. (Automated Sciences Group, Inc., Oak Ridge, TN (United States)); Hopkins, R.A. (Marrich, Inc., Knoxville, TN (United States)); Doll, W.E. (Oak Ridge National Lab., TN (United States))

    1992-02-01

    Between September 19, 1991 and October 8, 1991 personnel from Martin Marietta Energy Systems, Inc. (Energy Systems), Automated Sciences Group, Inc., and Marrich, Inc. performed a seismic refraction survey at the Advanced Neutron Source (ANS) preferred site. The purpose of this survey was to provide estimates of top-of-rock topography, based on seismic velocities, and to delineate variations in rock and soil velocities. Forty-four seismic refraction spreads were shot to determine top-of-rock depths at 42 locations. Nine of the seismic spreads were shot with long offsets to provide 216 top-of-rock depths for 4 seismic refraction profiles. The refraction spread locations were based on the grid for the ANS Phase I drilling program. Interpretation of the seismic refraction data supports the assumption that the top-of-rock surface generally follows the local topography. The shallow top-of-rock interface interpreted from the seismic refraction data is also supported by limited drill information at the site. Some zones of anomalous data are present that could be the result of locally variable weathering, a localized variation in shale content, or depth to top-of-rock greater than the site norm.

  8. On the effective refractive index of blood

    Science.gov (United States)

    Nahmad-Rohen, Alexander; Contreras-Tello, Humberto; Morales-Luna, Gesuri; García-Valenzuela, Augusto

    2016-01-01

    We calculated the real and imaginary parts of the effective refractive index {n}{eff} of blood as functions of wavelength from 400 to 800 nm; we employed van de Hulst’s theory, together with the anomalous diffraction approximation, for the calculation. We modelled blood as a mixture of plasma and erythrocytes. Our results indicate that erythrocyte orientation has a strong effect on {n}{eff}, making blood an optically anisotropic medium except when the erythrocytes are randomly oriented. In the case in which their symmetry axis is perpendicular to the wave vector, {n}{eff} equals the refractive index of plasma at certain wavelengths. Furthermore, the erythrocytes’ shape affects their contribution to {n}{eff} in an important way, implying that studies on the effective refractive index of blood should avoid approximating them as spheres or spheroids. Finally, the effective refractive index of blood predicted by van de Hulst’s theory is different from what would be obtained by averaging the refractive indices of its constituents weighted by volume; such a volume-weighted average is appropriate only for haemolysed blood. We then measured the real part of the refractive index of various blood solutions using two different experimental setups. One of the most important results of our expriment is that {n}{eff} is measurable to a good degree of precision even for undiluted blood, although not all measuring apparatuses are appropriate. The experimental data is self-consistent and in reasonable agreement with our theoretical calculations.

  9. Dose-response relationship for the induction of structural chromosome aberrations in human spermatozoa after in vitro exposure ti tritium. beta. -rays

    Energy Technology Data Exchange (ETDEWEB)

    Kamiguchi, Yujiroh; Tateno, Hiroyuki; Mikamo, Kazuya (Asahikawa Medical College (Japan). Department of Biological Sciences)

    1990-02-01

    THe effects of tritium (HTO) {beta}-rays on human sperm chromosomes were studied using our interspecific in vitro fertilization system between human spermatozoa and zona-free hamster oocytes. Semen samples were treated with media containing 1.53-24.3 mCi/ml HTO for about 80 min. 1290 spermatozoa from the controls and 1842 spermatozoa from the irradiated groups were karyotyped. The incidence of spermatozoa with structural chromosome aberrations increased linearly with increasing dosage. Breakage-type aberrations occurred far more frequently than exchange-type. Chromosome-type aberrations appeared far more frequently than chromatid-ype. All of these types of aberrations showed linear dose-dependent increases. The RBE valus of HTO {beta}-rays relative to X-rays were calculated for the above-mentioned 5 indices, respectively. Their RBE values franged from 1.89 to 3.00 when the absorbed dose was estimated to be the minimum, whereas the values ranged between 1.04 and 1.65 when the absorbed dose was estimated to be the maximum. (author). 15 refs.; 3 figs.; 4 tabs.

  10. Light rays in gravitating, refractive media

    International Nuclear Information System (INIS)

    Noonan, T.W.

    1982-01-01

    The field-to-particle method of H. P. Robertson is applied to the general-relativistic Maxwell equations in order to obtain the general-relativistic equation of motion for a photon in a refractive medium. For the special case of an uncharged, refractive, spherically symmetric mass, the exact first-order differential equation for the light-ray path is given

  11. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism

    Directory of Open Access Journals (Sweden)

    Li-Kun Xia

    2018-03-01

    Full Text Available AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs, contrast sensitivity (CS and dry eye parameters after small incision lenticule extraction (SMILE and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE of -8.11±1.09 diopters (D received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI and tear break-up time (TBUT were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13. The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00, and 0.14 D in the SMILE group (t=0.54, P=0.59 from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00, but the coma root mean square (RMS was higher in the SMILE group (0.59±0.26 than in the FS-LASIK group (0.29±0.14, P=0.00. The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long

  12. Fifth-order canonical geometric aberration analysis of electrostatic round lenses

    CERN Document Server

    Liu Zhi Xiong

    2002-01-01

    In this paper the fifth-order canonical geometric aberration patterns are analyzed and a numerical example is given on the basis of the analytical expressions of fifth-order aberration coefficients derived in the present work. The fifth-order spherical aberration, astigmatism and field curvature, and distortion are similar to the third-order ones and the fifth-order coma is slightly different. Besides, there are two more aberrations which do not exist in the third-order aberration: they are peanut aberration and elliptical coma in accordance with their shapes. In the numerical example, by using a cross-check of the calculated coefficients with those computed through the differential algebraic method, it has been verified that all the expressions are correct and the computational results are reliable with high precision.

  13. Chromosomal aberrations induced by alpha particles

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M.

    2005-01-01

    The chromosomal aberrations produced by the ionizing radiation are commonly used when it is necessary to establish the exposure dose of an individual, it is a study that is used like complement of the traditional physical systems and its application is only in cases in that there is doubt about what indicates the conventional dosimetry. The biological dosimetry is based on the frequency of aberrations in the chromosomes of the lymphocytes of the individual in study and the dose is calculated taking like reference to the dose-response curves previously generated In vitro. A case of apparent over-exposure to alpha particles to which is practiced analysis of chromosomal aberrations to settle down if in fact there was exposure and as much as possible, to determine the presumed dose is presented. (Author)

  14. Population based outcomes of cataract surgery in three tribal areas of Andhra Pradesh, India: risk factors for poor outcomes.

    Directory of Open Access Journals (Sweden)

    Rohit C Khanna

    Full Text Available PURPOSE: To report visual outcomes and risk factors for poor outcomes of cataract surgery in three Integrated Tribal Development Agency (ITDA areas of Andhra Pradesh, India. METHODS AND RESULTS: Using validated Rapid Assessment of Avoidable Blindness (RAAB methodology, a population based cross-sectional study, was conducted in three ITDA areas. A two-stage sampling procedure was used to select 7281 participants aged 50 years and above. Vision assessment using a tumbling E chart and standard ocular examinations were completed. Visual outcomes and risk factors for poor outcomes were assessed among subjects undergoing cataract surgery (1548 eyes of 1124 subjects. Mean age at surgery was 67±8 years; Among the operated eyes, presenting visual acuity (PVA and best corrected visual acuity (BCVA worse than 6/18 was seen in 492 (31.8%; 95% CI, 29.5-34.2% and 298 eyes (19.3%; 95% CI, 17.3-21.3%, respectively. Similarly, PVA and BCVA worse than 6/60 was seen in 219 (14.1%; 95% CI, 12.4-16% and 147 eyes (9.5%; 95% CI, 8.1-11.1%, respectively. When either eye was taken into consideration, the PVA and BCVA worse than 6/18 was seen in 323 (20.1%; 95% CI, 18.9-23% and 144 subjects (9.3%; 95% CI, 7.9-10.9%, respectively. PVA and BCVA worse than 6/60 was seen in 74 (4.8%; 95% CI, 3.8-6% and 49 subjects (3.2%; 95% CI, 2.4-4.2%, respectively. Posterior capsular opacification was seen in 51 of 1316 pseudophakic eyes (3.9%; 95% CI, 2.9-5.1%. In multivariable analysis among pseudophakic subjects with PVA worse than 6/18, increasing age (p = 0.002 and undergoing free surgery (p = 0.05 were independent risk factors. Undergoing surgery before 2005 (p = 0.05 and being illiterate (p = 0.05 were independent risk factors for BCVA worse than 6/18. CONCLUSIONS: There are changing trends with improved outcomes in cataract surgery among these tribal populations of India. However, post-operative refractive error correction remains an issue, especially for those

  15. REFRACTIVE ERROR STATUS IN BAYELSA STATE, NIGERIA

    African Journals Online (AJOL)

    LIVINGSTON

    deepening poverty because of their inability to see well” . In 2002, the .... all the refractions) and other health workers. During the period .... To the best of our knowledge, there is no ... 2020 and eliminate uncorrected refractive error within the ...

  16. Evidence for subwavelength imaging with positive refraction

    OpenAIRE

    Ma, Yun Gui; Sahebdivan, Sahar; Ong, C. K.; Tyc, Tomas; Leonhardt, Ulf

    2011-01-01

    The resolution of lenses is normally limited by the wave nature of light. Imaging with perfect resolution was believed to rely on negative refraction, but here we present experimental evidence for subwavelength imaging with positive refraction. Publisher PDF Peer reviewed

  17. Effect of refractive error on temperament and character properties

    Institute of Scientific and Technical Information of China (English)

    Emine; Kalkan; Akcay; Fatih; Canan; Huseyin; Simavli; Derya; Dal; Hacer; Yalniz; Nagihan; Ugurlu; Omer; Gecici; Nurullah; Cagil

    2015-01-01

    AIM: To determine the effect of refractive error on temperament and character properties using Cloninger’s psychobiological model of personality.METHODS: Using the Temperament and Character Inventory(TCI), the temperament and character profiles of 41 participants with refractive errors(17 with myopia,12 with hyperopia, and 12 with myopic astigmatism) were compared to those of 30 healthy control participants.Here, temperament comprised the traits of novelty seeking, harm-avoidance, and reward dependence, while character comprised traits of self-directedness,cooperativeness, and self-transcendence.RESULTS: Participants with refractive error showed significantly lower scores on purposefulness,cooperativeness, empathy, helpfulness, and compassion(P <0.05, P <0.01, P <0.05, P <0.05, and P <0.01,respectively).CONCLUSION: Refractive error might have a negative influence on some character traits, and different types of refractive error might have different temperament and character properties. These personality traits may be implicated in the onset and/or perpetuation of refractive errors and may be a productive focus for psychotherapy.

  18. Spherical aberration and other higher-order aberrations in the human eye : from summary wave-front analysis data to optical variables relevant to visual perception

    NARCIS (Netherlands)

    Jansonius, Nomdo M.

    Wave-front analysis data from the human eye are commonly presented using the aberration coefficient c(4)(0) (primary spherical aberration) together with an overall measure of all higher-order aberrations. If groups of subjects are compared, however, the relevance of an observed difference cannot

  19. Perfect imaging without negative refraction

    OpenAIRE

    Leonhardt, Ulf

    2009-01-01

    Perfect imaging has been believed to rely on negative refraction, but here we show that an ordinary positively-refracting optical medium may form perfect images as well. In particular, we establish a mathematical proof that Maxwell's fish eye in two-dimensional integrated optics makes a perfect instrument with a resolution not limited by the wavelength of light. We also show how to modify the fish eye such that perfect imaging devices can be made in practice. Our method of perfect focusing ma...

  20. Optical and Biometric Characteristics of Anisomyopia in Human Adults

    Science.gov (United States)

    Tian, Yibin; Tarrant, Janice; Wildsoet, Christine F.

    2011-01-01

    Purpose To investigate the role of higher order optical aberrations and thus retinal image degradation in the development of myopia, through the characterization of anisomyopia in human adults in terms of their optical and biometric characteristics. Methods The following data were collected from both eyes of fifteen young adult anisometropic myopes and sixteen isometropic myopes: subjective and objective refractive errors, corneal power and shape, monochromatic optical aberrations, anterior chamber depth, lens thickness, vitreous chamber depth, and best corrected visual acuity. Monochromatic aberrations were analyzed in terms of their higher order components, and further analyzed in terms of 31 optical quality metrics. Interocular differences for the two groups (anisomyopes vs. isomyopes) were compared and the relationship between measured ocular parameters and refractive errors also analyzed across all eyes. Results As expected, anisomyopes and isomyopes differed significantly in terms of interocular differences in vitreous chamber depth, axial length and refractive error. However, interocular differences in other optical properties showed no significant intergroup differences. Overall, higher myopia was associated with deeper anterior and vitreous chambers, higher astigmatism, more prolate corneas, and more positive spherical aberration. Other measured optical and biometric parameters were not significantly correlated with spherical refractive error, although some optical quality metrics and corneal astigmatism were significantly correlated with refractive astigmatism. Conclusions An optical cause for anisomyopia related to increased higher order aberrations is not supported by our data. Corneal shape changes and increased astigmatism in more myopic eyes may be a by-product of the increased anterior chamber growth in these eyes; likewise, the increased positive spherical aberration in more myopic eyes may be a product of myopic eye growth. PMID:21797915

  1. Statistical estimation of ultrasonic propagation path parameters for aberration correction.

    Science.gov (United States)

    Waag, Robert C; Astheimer, Jeffrey P

    2005-05-01

    Parameters in a linear filter model for ultrasonic propagation are found using statistical estimation. The model uses an inhomogeneous-medium Green's function that is decomposed into a homogeneous-transmission term and a path-dependent aberration term. Power and cross-power spectra of random-medium scattering are estimated over the frequency band of the transmit-receive system by using closely situated scattering volumes. The frequency-domain magnitude of the aberration is obtained from a normalization of the power spectrum. The corresponding phase is reconstructed from cross-power spectra of subaperture signals at adjacent receive positions by a recursion. The subapertures constrain the receive sensitivity pattern to eliminate measurement system phase contributions. The recursion uses a Laplacian-based algorithm to obtain phase from phase differences. Pulse-echo waveforms were acquired from a point reflector and a tissue-like scattering phantom through a tissue-mimicking aberration path from neighboring volumes having essentially the same aberration path. Propagation path aberration parameters calculated from the measurements of random scattering through the aberration phantom agree with corresponding parameters calculated for the same aberrator and array position by using echoes from the point reflector. The results indicate the approach describes, in addition to time shifts, waveform amplitude and shape changes produced by propagation through distributed aberration under realistic conditions.

  2. Recurrence-free survival, but not surgical therapy per se, determines 583 patients' long-term satisfaction following primary pilonidal sinus surgery.

    Science.gov (United States)

    Doll, Dietrich; Luedi, Markus M; Evers, Theo; Kauf, Peter; Matevossian, Edouard

    2015-05-01

    With pilonidal sinus disease (PSD) incidence increasing and patients freely choosing their surgeon, patients' interest issues have been brought forward estimating patient satisfaction following pilonidal sinus surgery. The influence of wound healing time and long-term recurrence rate on patient satisfaction in primary PSD surgery has not been investigated yet. Five hundred eighty-three patients (German military cohort) were interviewed, compiling wound healing time, aesthetic satisfaction, long-term recurrence-free survival and patient satisfaction having undergone primary open (PO) treatment, marsupialization (MARS) or primary midline closure (PMC) treatment. Recurrence rate was determined by Kaplan-Meier calculation following up to 20 years after primary PSD surgery. Patient satisfaction ranking from 1 to 10 (10 = max. satisfied) showed an average satisfaction of 8.2 (range 0-10; 95% confidence interval (CI) 7891-8250). In-hospital stay time was significantly longer in primary open (PO) and marsupialization (MARS) group as compared to primary midline closure (PMC; p < 0.0001, Kruskal-Wallis test). Satisfaction was comparable between treatment groups, and was neither linked to in-hospital stay time nor to longer outpatient wound care period or total treatment time. Recurrence-free survival, as seen in the PO and PMC treatment group, revealed a highly significant difference for all patients. Improvement in MARS patients with versus without recurrence was low, as satisfaction with primary treatment was lower as the other groups. Neither choice of surgical treatment nor treatment duration within hospital or after hospital influences patient satisfaction, as long as recurrence-free survival can be provided. Marsupialization was ranked lower in both groups (with or without recurrence), and should be abandoned, as patients are significantly less satisfied with either results, independent of recurrence.

  3. Clinical and theoretical results of intraocular lens power calculation for cataract surgery after photorefractive keratectomy for myopia.

    NARCIS (Netherlands)

    Odenthal, M.T.; Eggink, C.A.; Melles, G.R.J.; Pameyer, J.H.; Geerards, A.J.; Beekhuis, W.H.

    2002-01-01

    OBJECTIVES: To describe the refractive results of cataract surgery after photorefractive keratectomy (PRK) for patients with myopia, and to find a more accurate method to predict intraocular lens (IOL) power in these cases. DESIGN: Nonrandomized, retrospective clinical study. PATIENTS AND METHODS:

  4. Prevalence of cataract surgery and visual outcomes in Indian immigrants in Singapore: the Singapore Indian eye study.

    Science.gov (United States)

    Gupta, Preeti; Zheng, Yingfeng; Ting, Tay Wan; Lamoureux, Ecosse L; Cheng, Ching-Yu; Wong, Tien-Yin

    2013-01-01

    To determine the prevalence of cataract surgery and factors associated with post-surgical visual outcomes in migrant Indians living in Singapore. We conducted a population-based study in 3,400 Indian immigrants residing in Singapore-the Singapore Indian Eye Study (SINDI). All participants underwent comprehensive medical eye examination and a standardized interview. Post-operative visual impairment (VI) was defined as best-corrected or presenting visual acuity (BCVA or PVA) of 20/60 or worse. The age- and gender-standardized prevalence of cataract surgery was 9.7% (95% confidence interval [CI]: 8.9%, 10.7%) in Singapore resident Indians. Post-operative VI defined by BCVA occurred in 10.9% eyes (87/795). The main causes of post-operative VI were diabetic retinopathy (20.7%), posterior capsular opacification (18.4%), and age-related macular degeneration (12.6%). Undercorrected refractive error doubled the prevalence of post-operative VI when PVA was used. The rate of cataract surgery is about 10% in Indian residents in Singapore. Socioeconomic variables and migration had no significant impact on the prevalence of cataract surgery. Diabetic retinopathy was a major cause of post-operative VI in migrant Indians living in Singapore. Uncorrected postoperative refractive error remains an efficient way to improve vision.

  5. Higher order aberrations of the eye: Part one

    Directory of Open Access Journals (Sweden)

    Marsha Oberholzer

    2016-06-01

    Full Text Available This article is the first in a series of two articles that provide a comprehensive literature review of higher order aberrations (HOAs of the eye. The present article mainly explains the general principles of such HOAs as well as HOAs of importance, and the measuring apparatus used to measure HOAs of the eye. The second article in the series discusses factors contributing to variable results in measurements of HOAs of the eye. Keywords: Higher order aberrations; wavefront aberrations; aberrometer

  6. Dispersion characteristics of negative refraction sonic crystals

    International Nuclear Information System (INIS)

    Wu, L.-Y.; Chen, L.-W.; Wang, R.C.-C.

    2008-01-01

    Dispersion characteristics of negative refraction sonic crystals are investigated. The plane wave expansion method is used to calculate the equifrequency surface; the dependences of refractive direction on frequencies and incident angles for triangular lattices are shown. There exist the positive and negative refractive waves which include k.V g ≥0 and k.V g ≤0 in the second band for the triangular system. We also use the finite element method to demonstrate that the relative intensity of the transmitted acoustic waves is dependent on incident frequencies and angles. The positions of the partial band gaps obtained by the plane wave expansion method are in good agreement with those obtained by the finite element method. The sonic crystals with negative effective index are shown to have higher transmission intensities. By using the negative refraction behavior, we can design a sonic crystal plane lens to focus a sonic wave

  7. Circulating Tumor Cells with Aberrant ALK Copy Number Predict Progression-Free Survival during Crizotinib Treatment in ALK-Rearranged Non-Small Cell Lung Cancer Patients.

    Science.gov (United States)

    Pailler, Emma; Oulhen, Marianne; Borget, Isabelle; Remon, Jordi; Ross, Kirsty; Auger, Nathalie; Billiot, Fanny; Ngo Camus, Maud; Commo, Frédéric; Lindsay, Colin R; Planchard, David; Soria, Jean-Charles; Besse, Benjamin; Farace, Françoise

    2017-05-01

    The duration and magnitude of clinical response are unpredictable in ALK -rearranged non-small cell lung cancer (NSCLC) patients treated with crizotinib, although all patients invariably develop resistance. Here, we evaluated whether circulating tumor cells (CTC) with aberrant ALK -FISH patterns [ ALK -rearrangement, ALK -copy number gain ( ALK -CNG)] monitored on crizotinib could predict progression-free survival (PFS) in a cohort of ALK -rearranged patients. Thirty-nine ALK -rearranged NSCLC patients treated with crizotinib as first ALK inhibitor were recruited prospectively. Blood samples were collected at baseline and at an early time-point (2 months) on crizotinib. Aberrant ALK -FISH patterns were examined in CTCs using immunofluorescence staining combined with filter-adapted FISH after filtration enrichment. CTCs were classified into distinct subsets according to the presence of ALK -rearrangement and/or ALK -CNG signals. No significant association between baseline numbers of ALK -rearranged or ALK -CNG CTCs and PFS was observed. However, we observed a significant association between the decrease in CTC number with ALK -CNG on crizotinib and a longer PFS (likelihood ratio test, P = 0.025). In multivariate analysis, the dynamic change of CTC with ALK -CNG was the strongest factor associated with PFS (HR, 4.485; 95% confidence interval, 1.543-13.030, P = 0.006). Although not dominant, ALK -CNG has been reported to be one of the mechanisms of acquired resistance to crizotinib in tumor biopsies. Our results suggest that the dynamic change in the numbers of CTCs with ALK -CNG may be a predictive biomarker for crizotinib efficacy in ALK -rearranged NSCLC patients. Serial molecular analysis of CTC shows promise for real-time patient monitoring and clinical outcome prediction in this population. Cancer Res; 77(9); 2222-30. ©2017 AACR . ©2017 American Association for Cancer Research.

  8. Generation of highly confined photonic nanojet using crescent-shape refractive index profile in microsphere

    Science.gov (United States)

    Patel, H. S.; Kushwaha, P. K.; Swami, M. K.

    2018-05-01

    Photonic nanojets (PNJs) owing to their sub-wavelength near-field features have found many interesting applications like nanoscopy, nano photolithography, high density optical storage, enhancement of Raman signal and single molecule spectroscopy etc. More recently, the focus of research has been on tailoring of PNJs either for better confinement and thus higher peak intensity or for elongation of nanojet for high resolution far field applications. In this paper, we show that crescent-shape refractive index profile (CSRP) of microspheres can be used to generate highly confined PNJ. By optimizing the refractive index of different layers in CSRP microsphere, we show a free space confinement down to ∼ λ / 4 . 5 (FWHM ∼ 110 nm for excitation with 500 nm wavelength). Further, it was observed that the optical properties of substrates also modulate the PNJ characteristics and lead to a further improvement in the transverse confinement to ∼ λ / 6 . 7.

  9. Integrated refractive index optical ring resonator detector for capillary electrophoresis.

    Science.gov (United States)

    Zhu, Hongying; White, Ian M; Suter, Jonathan D; Zourob, Mohammed; Fan, Xudong

    2007-02-01

    We developed a novel miniaturized and multiplexed, on-capillary, refractive index (RI) detector using liquid core optical ring resonators (LCORRs) for future development of capillary electrophoresis (CE) devices. The LCORR employs a glass capillary with a diameter of approximately 100 mum and a wall thickness of a few micrometers. The circular cross section of the capillary forms a ring resonator along which the light circulates in the form of the whispering gallery modes (WGMs). The WGM has an evanescent field extending into the capillary core and responds to the RI change due to the analyte conducted in the capillary, thus permitting label-free measurement. The resonating nature of the WGM enables repetitive light-analyte interaction, significantly enhancing the LCORR sensitivity. This LCORR architecture achieves dual use of the capillary as a sensor head and a CE fluidic channel, allowing for integrated, multiplexed, and noninvasive on-capillary detection at any location along the capillary. In this work, we used electro-osmotic flow and glycerol as a model system to demonstrate the fluid transport capability of the LCORRs. In addition, we performed flow speed measurement on the LCORR to demonstrate its flow analysis capability. Finally, using the LCORR's label-free sensing mechanism, we accurately deduced the analyte concentration in real time at a given point on the capillary. A sensitivity of 20 nm/RIU (refractive index units) was observed, leading to an RI detection limit of 10-6 RIU. The LCORR marries photonic technology with microfluidics and enables rapid on-capillary sample analysis and flow profile monitoring. The investigation in this regard will open a door to novel high-throughput CE devices and lab-on-a-chip sensors in the future.

  10. Combined resection of aberrant right hepatic artery without anastomosis in panceaticoduodenectomy for pancreatic head cancer: A case report.

    Science.gov (United States)

    Nanashima, Atsushi; Imamura, Naoya; Tsuchimochi, Yuki; Hiyoshi, Masahide; Fujii, Yoshiro

    2016-01-01

    This case report is intended to inform pancreas surgeons of our experience in operative management of aberrant pancreatic artery. A 63-year-old woman was admitted to our institute's Department of Surgery with obstructive jaundice, and the pancreas head tumor was found. To improve liver dysfunction, an endoscopic retrograde nasogastric biliary drainage tube was placed in the bile duct. Endoscopic fine-needle aspiration showed a pancreas head carcinoma invading the common bile duct, the aberrant right hepatic artery arising from the superior mesenteric artery, and the portal vein. Enhanced computed tomography showed the communicating artery between the right and left hepatic artery via the hepatic hilar plate. By way of imaging preoperative examination, a pancreaticoduodenectomy combined resection of the aberrant right hepatic artery and portal vein was conducted without arterial anastomosis. Hepatic arterial flow was confirmed by intraoperative Doppler ultrasonography, and R0 resection without tumor exposure at the dissected plane was achieved. The patient's postoperative course was uneventful. In this case report, perioperative detail examination by imaging diagnosis with respect to hepatic arterial communication to achieve curative resection in a pancreas head cancer was necessary. Non-anastomosis of hepatic artery was achieved, and the necessity of R0 resection was stressed by such management. By the preoperative and intraoperative imaging managements conducted, combined resection of the aberrant right hepatic artery without anastomosis was achieved by pancreaticoduodenectomy for pancreas head cancer. However, improvements in imaging diagnosis and careful management of R0 resection are important. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. Effect of spherical aberration on scintillations of Gaussian beams in atmospheric turbulence

    International Nuclear Information System (INIS)

    Ji, Xiaoling; Deng, Jinping

    2014-01-01

    The effect of spherical aberration on scintillations of Gaussian beams in weak, moderate and strong turbulence is studied using numerical simulation method. It is found that the effect of the negative spherical aberration on the on-axis scintillation index is quite different from that of the positive spherical aberration. In weak turbulence, the positive spherical aberration results in a decrease of the on-axis scintillation index on propagation, but the negative spherical aberration results in an increase of the on-axis scintillation index when the propagation distance is not large. In particular, in weak turbulence the negative spherical aberration may cause peaks of the on-axis scintillation index, and the peaks disappear in moderate and strong turbulence, which is explained in physics. The strong turbulence leads to less discrepancy among scintillations of Gaussian beams with and without spherical aberration. - Highlights: • In weak turbulence scintillations can be suppressed using positive spherical aberration. • In weak turbulence scintillations may be very large due to negative spherical aberration. • The effect of spherical aberration on scintillations is less with increasing of turbulence

  12. Effect of spherical aberration on scintillations of Gaussian beams in atmospheric turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Xiaoling, E-mail: jiXL100@163.com; Deng, Jinping

    2014-07-18

    The effect of spherical aberration on scintillations of Gaussian beams in weak, moderate and strong turbulence is studied using numerical simulation method. It is found that the effect of the negative spherical aberration on the on-axis scintillation index is quite different from that of the positive spherical aberration. In weak turbulence, the positive spherical aberration results in a decrease of the on-axis scintillation index on propagation, but the negative spherical aberration results in an increase of the on-axis scintillation index when the propagation distance is not large. In particular, in weak turbulence the negative spherical aberration may cause peaks of the on-axis scintillation index, and the peaks disappear in moderate and strong turbulence, which is explained in physics. The strong turbulence leads to less discrepancy among scintillations of Gaussian beams with and without spherical aberration. - Highlights: • In weak turbulence scintillations can be suppressed using positive spherical aberration. • In weak turbulence scintillations may be very large due to negative spherical aberration. • The effect of spherical aberration on scintillations is less with increasing of turbulence.

  13. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    Science.gov (United States)

    Zhao, Hao-Xin; Xu, Bing; Xue, Li-Xia; Dai, Yun; Liu, Qian; Rao, Xue-Jun

    2008-04-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory.

  14. Influence of Misalignment on High-Order Aberration Correction for Normal Human Eyes

    International Nuclear Information System (INIS)

    Hao-Xin, Zhao; Bing, Xu; Li-Xia, Xue; Yun, Dai; Qian, Liu; Xue-Jun, Rao

    2008-01-01

    Although a compensation device can correct aberrations of human eyes, the effect will be degraded by its misalignment, especially for high-order aberration correction. We calculate the positioning tolerance of correction device for high-order aberrations, and within what degree the correcting effect is better than low-order aberration (defocus and astigmatism) correction. With fixed certain misalignment within the positioning tolerance, we calculate the residual wavefront rms aberration of the first-6 to first-35 terms along with the 3rd-5th terms of aberrations corrected, and the combined first-13 terms of aberrations are also studied under the same quantity of misalignment. However, the correction effect of high-order aberrations does not meliorate along with the increase of the high-order terms under some misalignment, moreover, some simple combined terms correction can achieve similar result as complex combinations. These results suggest that it is unnecessary to correct too much the terms of high-order aberrations which are difficult to accomplish in practice, and gives confidence to correct high-order aberrations out of the laboratory

  15. Refractive index inhomogeneity within an aerogel block

    International Nuclear Information System (INIS)

    Bellunato, T.; Calvi, M.; Da Silva Costa, C.F.; Matteuzzi, C.; Musy, M.; Perego, D.L.

    2006-01-01

    Evaluating local inhomogeneities of the refractive index inside aerogel blocks to be used as Cherenkov radiator is important for a high energy physics experiment where angular resolution is crucial. Two approaches are described and compared. The first one is based on the bending of a laser beam induced by refractive index gradients along directions normal to the unperturbed optical path. The second method exploits the Cherenkov effect itself by shooting an ultra-relativistic collimated electron beam through different points of the aerogel surface. Local refractive index variations result in sizable differences in the Cherenkov photons distribution

  16. Possible mechanisms of chromosomal aberrations: VII. Comparative dynamics of sister chromatid disjunction and realization of radiation-induced chromosomal aberrations during mitosis

    International Nuclear Information System (INIS)

    Lebedeva, L.I.; Akhmamet'eva, E.M.

    1994-01-01

    An increase in radiation-induced chromosomal aberrations during c-metaphase sister chromatid disjunction was demonstrated in murine bone marrow cells exposed to a total γ-irradiation at 0.5 Gy. Caffeine (Cf) treatment during mitosis partially suppressed the chromatid disjunction rate and increased the number of radiation-induced aberrations in this mitosis. Nalidixic acid (NA) treatment of c-metaphase cells completely suppressed chromatid disjunction and the realization of induced aberrations. Topoisomerase 2 was assumed to be involved during mitosis in both processes

  17. Cryogenic refractive index of Heraeus homosil glass

    Science.gov (United States)

    Miller, Kevin H.; Quijada, Manuel A.; Leviton, Douglas B.

    2017-08-01

    This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34—3.16 μm and temperature range of 120—335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASA's Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a fieldwidened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitive performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/dλ) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in the literature.

  18. Refractive index as materials property. Der Brechungsindex als Stoffeigenschaft

    Energy Technology Data Exchange (ETDEWEB)

    Zilian, U. (Ciba-Geigy AG, Basel (Switzerland))

    1991-10-01

    The investigation of the relationship between refractive index (n) and molecular structure of a series of gases, liquids, and solids led to the conclusion that the refractive index of a substance is an independent molecular property. Light is refracted by two types of electron pairs. a) Bonding Electron Pairs (BEP) and b) Response Electron Pairs (REP). - Paraffins exhibit only BEPs which can easily be counted. REP is a new term we introduce to quantify the effects of several nonbonding electrons. The inert gases, for example, refract solely with REPs. They can be determined, and the most important ones are herein tabulated or delineated in the text. For compounds with known formular weight (M) and density (d), the refractive index can be simply calculated using the following formula. (orig.).

  19. Chromosome aberration analysis based on a beta-binomial distribution

    International Nuclear Information System (INIS)

    Otake, Masanori; Prentice, R.L.

    1983-10-01

    Analyses carried out here generalized on earlier studies of chromosomal aberrations in the populations of Hiroshima and Nagasaki, by allowing extra-binomial variation in aberrant cell counts corresponding to within-subject correlations in cell aberrations. Strong within-subject correlations were detected with corresponding standard errors for the average number of aberrant cells that were often substantially larger than was previously assumed. The extra-binomial variation is accomodated in the analysis in the present report, as described in the section on dose-response models, by using a beta-binomial (B-B) variance structure. It is emphasized that we have generally satisfactory agreement between the observed and the B-B fitted frequencies by city-dose category. The chromosomal aberration data considered here are not extensive enough to allow a precise discrimination between competing dose-response models. A quadratic gamma ray and linear neutron model, however, most closely fits the chromosome data. (author)

  20. Visual quality analysis of femtosecond LASIK and iris location guided mechanical SBK for high myopia

    Directory of Open Access Journals (Sweden)

    Hong-Su Jiang

    2015-07-01

    Full Text Available AIM: To make a analysis of visual quality of iris location guided femtosecond laser assisted in situ keratomi(LASIKand iris location guided mechanical sub-bowman keratomileusis(SBKfor high myopia treatment. METHODS:Femtosecond LASIK(study groupwas performed in 102 eyes of 51 patients with high myopia and 70 eyes of 35 patients were received mechanical SBK(control groupfrom January to October 2013. The spherical refraction of all the patients was from -6.00~-9.50D. Best corrected visual acuity(BCVAof the patients was ≥1.0. Uncorrected visual acuity(UCVA, BCVA, thickness of cornea flap, contrast sensitivity function(CSFand senior ocular aberration were examined in these patients and follow-up was 1a. RESULTS: At 1a after surgery 94.1% UCVA in study group reached ≥1.0 and there was 94.3% in control group. There was no significant difference between two groups(P>0.05. Residual refraction of study group was -0.08±0.10 D and control group was -0.10±0.07 D. There was no significant difference of residual refraction between two groups(P>0.05. C12, C8 of senior ocular aberration and RMSH in study group was less than control group, amplification: 0.1642±0.0519 and 0.2229±0.0382(t=8.077, Pt=0.556, P>0.05. C8 was 0.0950±0.069 and 0.1858±0.095(t=7.261, Pt=12.801, PP>0.05.CONCLUSION: Femtosecond LASIK and mechanical SBK is effective for high myopia. Compared to mechanical SBK, femtosecond LASIK shows more advantages in the senior ocular aberration and visual quality. The cornea flap is more regular from central to peripheral area with femtosecond laser.

  1. Refractive Results: Safety and Efficacy of Secondary Piggyback Sensar™ AR40 Intraocular Lens Implantation to Correct Pseudophakic Refractive Error

    Directory of Open Access Journals (Sweden)

    Alahmady Hamad Alsmman Hassan

    2016-01-01

    Full Text Available In this study we evaluate the visual outcomes, safety, efficacy, and stability of implanting of second sulcus intraocular lens (IOL to correct unsatisfied ametropic patients after phacoemulsification. Methods. Retrospective study of 15 eyes (15 patients underwent secondary intraocular lens implanted into the ciliary sulcus. The IOL used was a Sensar IOL three-piece foldable hydrophobic acrylic IOL. The first IOL in all patients was acrylic intrabagal IOL implanted in uncomplicated phacoemulsification surgery. Results. Fifteen eyes (15 patients were involved in this study. Preoperatively, mean log⁡MAR UDVA and CDVA were 0.88 ± 0.22 and 0.19 ± 0.13, respectively, with a mean follow-up of 28 months (range: 24 to 36 months. At the end of the follow-up, all eyes achieved log⁡MAR UDVA of 0.20 ± 0.12 with postoperative refraction ranging from 0.00 to −0.50 D of attempted emmetropia. Conclusions. Implantation of the second sulcus SensarAR40 IOL was found to be safe, easy, and simple technique for management of ametropia following uncomplicated phacoemulsification.

  2. Clinical outcomes of small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a Meta-analysis

    Science.gov (United States)

    Yan, Huan; Gong, Li-Yan; Huang, Wei; Peng, Yan-Li

    2017-01-01

    AIM To evaluate the possible differences in visual quality between small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) for myopia. METHODS A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PubMed, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (PLASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK. PMID:28944205

  3. Chromosome aberrations: plants to human and Feulgen to FISH

    International Nuclear Information System (INIS)

    Natarajan, A.T.

    2005-01-01

    Chromosome aberrations and their impact on human health have been recognized for a long time. In the 1950s, in India, studies on induced chromosome aberrations in plants were initiated by Swaminathan and his students. I trace here the impact of these initial studies on further developments in this field. The studies which were started in plants have been extended to mammals (including human) and the simple squash and solid staining have been improved by molecular cytogenetic techniques, thus enabling accurate identification and quantification of different types of chromosome aberrations. These studies have also thrown light on the mechanisms of chromosome aberration formation, especially following exposure to ionizing radiation. (author)

  4. Measurements of photoinduced refractive index changes in ...

    Indian Academy of Sciences (India)

    Abstract. We report the pump–probe measurements of nonlinear refractive index changes in photochromic bacteriorhodopsin films. The photoinduced absorption is caused by pump beam at 532 nm and the accompanying refractive index changes are studied using a probe beam at 633 nm. The proposed technique is ...

  5. Refractive index inversion based on Mueller matrix method

    Science.gov (United States)

    Fan, Huaxi; Wu, Wenyuan; Huang, Yanhua; Li, Zhaozhao

    2016-03-01

    Based on Stokes vector and Jones vector, the correlation between Mueller matrix elements and refractive index was studied with the result simplified, and through Mueller matrix way, the expression of refractive index inversion was deduced. The Mueller matrix elements, under different incident angle, are simulated through the expression of specular reflection so as to analyze the influence of the angle of incidence and refractive index on it, which is verified through the measure of the Mueller matrix elements of polished metal surface. Research shows that, under the condition of specular reflection, the result of Mueller matrix inversion is consistent with the experiment and can be used as an index of refraction of inversion method, and it provides a new way for target detection and recognition technology.

  6. Radiation-induced cellular reproductive death and chromosome aberrations

    International Nuclear Information System (INIS)

    Bedford, J.S.; Mitchell, J.B.; Griggs, H.G.; Bender, M.A.

    1978-01-01

    If a major mode of cell killing by ionizing radiation is the death of cells containing visible chromosomal aberrations, as for example from anaphase-bridge formation at mitosis, then cells bearing such aberrations should be selectively eliminated from the population, resulting in an increased survival potential for the population remaining at each succeeding cell generation. Using synchronized V79B Chinese hamster cells, we measured the aberration frequency and the colony-forming ability of mitotic cells at each of the first three generations following irradiation in G1. Cells were resynchronized by mechanial harvest at each succeeding mitosis after irradiation in order to avoid mixing of generations in the cell population at later sampling times. As anticipated, the chromosome aberration frequencies decreased markedly from the first to the second and from the second to the third mitosis. The surviving fraction, however, was virtually the same for plating assays carried out immediately after irradiation, at the first, or at the second mitosis. The surviving fraction was significantly higher for cells reaching the third postirradiation mitosis. Survival and aberration frequencies were assayed again at approximately the fourteenth postirradiation division, by which time the irradiated and control populations were not significantly different

  7. Theory of aberration fields for general optical systems with freeform surfaces.

    Science.gov (United States)

    Fuerschbach, Kyle; Rolland, Jannick P; Thompson, Kevin P

    2014-11-03

    This paper utilizes the framework of nodal aberration theory to describe the aberration field behavior that emerges in optical systems with freeform optical surfaces, particularly φ-polynomial surfaces, including Zernike polynomial surfaces, that lie anywhere in the optical system. If the freeform surface is located at the stop or pupil, the net aberration contribution of the freeform surface is field constant. As the freeform optical surface is displaced longitudinally away from the stop or pupil of the optical system, the net aberration contribution becomes field dependent. It is demonstrated that there are no new aberration types when describing the aberration fields that arise with the introduction of freeform optical surfaces. Significantly it is shown that the aberration fields that emerge with the inclusion of freeform surfaces in an optical system are exactly those that have been described by nodal aberration theory for tilted and decentered optical systems. The key contribution here lies in establishing the field dependence and nodal behavior of each freeform term that is essential knowledge for effective application to optical system design. With this development, the nodes that are distributed throughout the field of view for each aberration type can be anticipated and targeted during optimization for the correction or control of the aberrations in an optical system with freeform surfaces. This work does not place any symmetry constraints on the optical system, which could be packaged in a fully three dimensional geometry, without fold mirrors.

  8. Theoretical analyses of the refractive implications of transepithelial PRK ablations.

    Science.gov (United States)

    Arba Mosquera, Samuel; Awwad, Shady T

    2013-07-01

    To analyse the refractive implications of single-step, transepithelial photorefractive keratectomy (TransPRK) ablations. A simulation for quantifying the refractive implications of TransPRK ablations has been developed. The simulation includes a simple modelling of corneal epithelial profiles, epithelial ablation profiles as well as refractive ablation profiles, and allows the analytical quantification of the refractive implications of TransPRK in terms of wasted tissue, achieved optical zone (OZ) and induced refractive error. Wasted tissue occurs whenever the actual corneal epithelial profile is thinner than the applied epithelial ablation profile, achieved OZ is reduced whenever the actual corneal epithelial profile is thicker than the applied epithelial ablation profile and additional refractive errors are induced whenever the actual difference centre-to-periphery in the corneal epithelial profile deviates from the difference in the applied epithelial ablation profile. The refractive implications of TransPRK ablations can be quantified using simple theoretical simulations. These implications can be wasted tissue (∼14 µm, if the corneal epithelial profile is thinner than the ablated one), reduced OZ (if the corneal epithelial profile is thicker than ablated one, very severe for low corrections) and additional refractive errors (∼0.66 D, if the centre-to-periphery progression of the corneal epithelial profile deviates from the progression of the ablated one). When TransPRK profiles are applied to normal, not previously treated, non-pathologic corneas, no specific refractive implications associated to the transepithelial profile can be anticipated; TransPRK would provide refractive outcomes equal to those of standard PRK. Adjustments for the planned OZ and, in the event of retreatments, for the target sphere can be easily derived.

  9. Annals of Pediatric Surgery

    African Journals Online (AJOL)

    The Annals of Pediatric Surgery is striving to fill an important niche that provides focus to clinical care, technical innovation and clinical research. ... Nonconventionalmesocaval prosthetic shunt interposition in refractory case with portal hypertension in a 10-kg female infant · EMAIL FREE FULL TEXT EMAIL FREE FULL ...

  10. Influence of changes in an eye's optical system on refraction

    Science.gov (United States)

    Bartkowska, Janina

    1998-10-01

    The optical system of eye is composed of cornea, lens, anterior chamber, and vitreous body. In the standard schematic eye there are 6 refracting surfaces. The changes of the curvature radii, of the distances between them, of the refractive indices influence the ametropia, refractive power of the eye and retinal image size. The influence of these changes can be appreciated by ray tracing or by an analytical method. There are presented simplified formulae for the differentials of ametropia and refractive power of the eye with respect to the surfaces curvatures, refracting power of cornea and lens, refractive indices. The relations are valid too for bigger changes if ametropia is measured in the cornea vertex. The formulae for the differentials with respect to distances, lens translation, eye axis length are valid if ametropia is measured in the object focus of the eye.

  11. Compact Aberration-Free Relay-Imaging Multi-Pass Layouts for High-Energy Laser Amplifiers

    Directory of Open Access Journals (Sweden)

    Jörg Körner

    2016-11-01

    Full Text Available We present the results from a theoretical investigation of laser beam propagation in relay imaging multi-pass layouts, which recently found application in high-energy laser amplifiers. Using a method based on the well-known ABCD-matrix formalism and proven by ray tracing, it was possible to derive a categorization of such systems. Furthermore, basic rules for the setup of such systems and the compensation for low order aberrations are derived. Due to the introduced generalization and parametrization, the presented results can immediately be applied to any system of the investigated kinds for a wide range of parameters, such as number of round-trips, focal lengths and optics sizes. It is shown that appropriate setups allow a close-to-perfect compensation of defocus caused by a thermal lens and astigmatism caused by non-normal incidence on the imaging optics, as well. Both are important to avoid intensity spikes leading to damages of optics in multi-pass laser amplifiers.

  12. A case report of central toxic keratopathy in a patient post TransPRK (followed by corneal collagen cross-linking

    Directory of Open Access Journals (Sweden)

    Davey N

    2017-04-01

    Full Text Available Nicholas Davey, Ioannis M Aslanides, Vasilis Selimis Emmetropia Mediterranean Eye Institute, Heraklion, Crete, Greece Purpose: The purpose of this article is to report a case of central toxic keratopathy in a patient post transepithelial photorefractive keratectomy (TransPRK, followed immediately by corneal collagen cross-linking.Methods: This article describes the case of a 26-year-old male after bilateral aberration-free, TransPRK laser (Schwind Amaris 750S. The procedure was performed for compound myopic astigmatism in November 2015, followed immediately by accelerated corneal collagen cross-linking for early keratoconus.Results: From day 3 post-op, tear film debris underneath both contact lenses with corneal haze and early, progressive central anterior stromal opacity formation only in the left eye were noted. At 2 weeks post-op, the left eye was noted to have a significant hyperopic shift with central corneal thinning in the anterior stroma. A central anterior stromal dense opacity had formed in the left eye with the surrounding superficial stromal haze. As of month 2, the opacity gradually started to improve in size and density. The hyperopic shift peaked at 2 months and continued to improve, largely due to epithelial compensation with a gradual recovery of stromal thickness.Conclusion: The question remains as to what provokes the typical central corneal necrosis/thinning in central toxic keratopathy. We hypothesize that the space between the contact lens and the corneal surface post TransPRK is prone to a “pseudo-interface pathology” that could mimic diffuse lamellar keratitis-like pathology. Suboptimal lid hygiene, resulting in tear film combinations of bacteria, inflammatory cells, matrix metalloproteinases and other proteolytic enzymes, contributes to the degradation of vulnerable, exposed collagen stromal tissue post TransPRK or any surface corneal ablation. Refractive surgeons should maintain a healthy lid margin and tear

  13. Conical Refraction: new observations and a dual cone model.

    Science.gov (United States)

    Sokolovskii, G S; Carnegie, D J; Kalkandjiev, T K; Rafailov, E U

    2013-05-06

    We propose a paraxial dual-cone model of conical refraction involving the interference of two cones of light behind the exit face of the crystal. The supporting experiment is based on beam selecting elements breaking down the conically refracted beam into two separate hollow cones which are symmetrical with one another. The shape of these cones of light is a product of a 'competition' between the divergence caused by the conical refraction and the convergence due to the focusing by the lens. The developed mathematical description of the conical refraction demonstrates an excellent agreement with experiment.

  14. An aberrant precision account of autism.

    Directory of Open Access Journals (Sweden)

    Rebecca P Lawson

    2014-05-01

    Full Text Available Autism is a neurodevelopmental disorder characterised by problems with social-communication, restricted interests and repetitive behaviour. A recent and controversial article presented a compelling normative explanation for the perceptual symptoms of autism in terms of a failure of Bayesian inference (Pellicano and Burr, 2012. In response, we suggested that when Bayesian interference is grounded in its neural instantiation – namely, predictive coding – many features of autistic perception can be attributed to aberrant precision (or beliefs about precision within the context of hierarchical message passing in the brain (Friston et al., 2013. Here, we unpack the aberrant precision account of autism. Specifically, we consider how empirical findings – that speak directly or indirectly to neurobiological mechanisms – are consistent with the aberrant encoding of precision in autism; in particular, an imbalance of the precision ascribed to sensory evidence relative to prior beliefs.

  15. Higher-order aberrations and visual acuity after LASEK.

    Science.gov (United States)

    Urgancioglu, Berrak; Bilgihan, Kamil; Ozturk, Sertac

    2008-08-01

    To determine ocular higher-order aberrations (HOAs) in eyes with supernormal vision after myopic astigmatic laser subepithelial keratomileusis (LASEK) and to compare the findings with those in eyes with natural supernormal vision. Ocular HOAs were measured after LASEK in 20 eyes of 12 myopic astigmatic patients with postoperative uncorrected visual acuity (UCVA) of >20/16 (group 1). Patients who were included in the study had no visual symptoms like glare, halo or double vision. The measurements were taken 8.3 +/- 3 months after LASEK surgery. In group 2 ocular HOAs were examined in 20 eyes of 10 subjects with natural UCVA of >20/16 as a control. Measurements were taken across a pupil with a diameter of 4.0 mm and 6.0 mm. Root-mean-square (RMS) values of HOAs, Z(3)-1, Z(3)1, Z(4)0, Z(5)-1, Z(5)1 and Z(6)0 were analyzed. The mean RMS values for each order were higher in group 1 when compared with group 2 at 4.0 mm and 6.0 mm pupil diameters. There was no statistically significant difference between groups in spherical and coma aberrations (P > 0.05). Mean RMS values for total HOAs were 0.187 +/- 0.09 microm at 4.0 mm and 0.438 +/- 0.178 microm at 6.0 mm pupil in group 1 and 0.120 +/- 0.049 microm at 4.0 mm and 0.344 +/- 0.083 microm at 6.0 mm pupil in group 2. The difference between groups in total HOAs was statistically significant at 4.0 mm and 6.0 mm pupil diameters (P < 0.05). Ocular HOAs exist in eyes with supernormal vision. After LASEK, the amount of HOAs of the eye increases under both mesopic and photopic conditions. However the amount of HOA increase does not seem to be consistent with visual symptoms.

  16. Turbulence-Free Double-slit Interferometer

    Science.gov (United States)

    Smith, Thomas A.; Shih, Yanhua

    2018-02-01

    Optical turbulence can be detrimental for optical observations. For instance, atmospheric turbulence may reduce the visibility or completely blur out the interference produced by an interferometer in open air. However, a simple two-photon interference theory based on Einstein's granularity picture of light makes a turbulence-free interferometer possible; i.e., any refraction index, length, or phase variations along the optical paths of the interferometer do not have any effect on its interference. Applying this mechanism, the reported experiment demonstrates a two-photon double-slit interference that is insensitive to atmospheric turbulence. The turbulence-free mechanism and especially the turbulence-free interferometer would be helpful in optical observations that require high sensitivity and stability such as for gravitational-wave detection.

  17. Image based method for aberration measurement of lithographic tools

    Science.gov (United States)

    Xu, Shuang; Tao, Bo; Guo, Yongxing; Li, Gongfa

    2018-01-01

    Information of lens aberration of lithographic tools is important as it directly affects the intensity distribution in the image plane. Zernike polynomials are commonly used for a mathematical description of lens aberrations. Due to the advantage of lower cost and easier implementation of tools, image based measurement techniques have been widely used. Lithographic tools are typically partially coherent systems that can be described by a bilinear model, which entails time consuming calculations and does not lend a simple and intuitive relationship between lens aberrations and the resulted images. Previous methods for retrieving lens aberrations in such partially coherent systems involve through-focus image measurements and time-consuming iterative algorithms. In this work, we propose a method for aberration measurement in lithographic tools, which only requires measuring two images of intensity distribution. Two linear formulations are derived in matrix forms that directly relate the measured images to the unknown Zernike coefficients. Consequently, an efficient non-iterative solution is obtained.

  18. Cell survival and radiation induced chromosome aberrations. Pt. 2

    International Nuclear Information System (INIS)

    Bauchinger, M.; Schmid, E.; Braselmann, H.

    1986-01-01

    Human peripheral lymphocytes were irradiated in whole blood with 0.5-4.0 Gy of 220 kVp X-rays and the frequency of chromosome aberrations was determined in 1st or 2nd division metaphases discriminated by fluorescence plus giemsa staining. Using the empirical distributions of aberrations among cells, cell survival and transmission of aberrations were investigated. Considering both daughter cells, we found that 20% of fragments and 55% of dicentrics or ring chromosomes are lost during the 1st cell division; i.e. cell survival rate from 1st to 2nd generation is mainly influenced by anaphase bridging of these two-hit aberrations. Cell survival to 2nd mitosis was calculated considering this situation and compared with the survival derived from the fraction of M1 cells without unstable aberrations. The resulting shouldered survival curves showed significantly different slopes, indicating that cell reproductive death is overestimated in the latter approach. (orig.)

  19. Revisiting Cross-Channel Information Transfer for Chromatic Aberration Correction

    KAUST Repository

    Sun, Tiancheng; Peng, Yifan; Heidrich, Wolfgang

    2017-01-01

    Image aberrations can cause severe degradation in image quality for consumer-level cameras, especially under the current tendency to reduce the complexity of lens designs in order to shrink the overall size of modules. In simplified optical designs, chromatic aberration can be one of the most significant causes for degraded image quality, and it can be quite difficult to remove in post-processing, since it results in strong blurs in at least some of the color channels. In this work, we revisit the pixel-wise similarity between different color channels of the image and accordingly propose a novel algorithm for correcting chromatic aberration based on this cross-channel correlation. In contrast to recent weak prior-based models, ours uses strong pixel-wise fitting and transfer, which lead to significant quality improvements for large chromatic aberrations. Experimental results on both synthetic and real world images captured by different optical systems demonstrate that the chromatic aberration can be significantly reduced using our approach.

  20. Revisiting Cross-Channel Information Transfer for Chromatic Aberration Correction

    KAUST Repository

    Sun, Tiancheng

    2017-12-25

    Image aberrations can cause severe degradation in image quality for consumer-level cameras, especially under the current tendency to reduce the complexity of lens designs in order to shrink the overall size of modules. In simplified optical designs, chromatic aberration can be one of the most significant causes for degraded image quality, and it can be quite difficult to remove in post-processing, since it results in strong blurs in at least some of the color channels. In this work, we revisit the pixel-wise similarity between different color channels of the image and accordingly propose a novel algorithm for correcting chromatic aberration based on this cross-channel correlation. In contrast to recent weak prior-based models, ours uses strong pixel-wise fitting and transfer, which lead to significant quality improvements for large chromatic aberrations. Experimental results on both synthetic and real world images captured by different optical systems demonstrate that the chromatic aberration can be significantly reduced using our approach.