WorldWideScience

Sample records for zeiss eth2 theodolites

  1. Electronic theodolite intersection systems

    OpenAIRE

    Bingley, R. M.

    1990-01-01

    The development of electronic surveying instruments, such as electronic theodolites, and concurrent advances in computer technology, has revolutionised engineering surveying; one of the more recent examples being the introduction of Electronic Theodolite Intersection Systems (ETISs). An ETIS consists of two or more electronic theodolites and a computer, with peripheral hardware and suitable software. The theoretical principles on which they are based have been known for a long time, but ...

  2. An eighteenth century travelling theodolite.

    Science.gov (United States)

    Malaquias, Isabel

    2016-01-01

    An old topographic compass displayed in a showroom of the Museu de Astronomia e Ciências Afins (MAST), in Rio de Janeiro, Brazil, took our curiosity namely because of its resemblance to a theodolite, described by J.H. de Magellan. Not many things were known about its previous history. From the different documents studied, and the characteristics of this singular theodolite, it must have belonged to the collections of instruments acquired for the Brazilian border demarcations undertaken after the Santo Ildefonso Treaty, agreed to by the Portuguese and Spanish courts in 1777. Several instruments were bought in London, and supervised and chosen by Magellan, the Portuguese instruments expert. We present arguments in favour of this conclusion.

  3. The Planetarium and the Carl Zeiss Corporation, 1923-1933

    Science.gov (United States)

    Boyce-Jacino, Katherine

    2018-01-01

    The Carl Zeiss Company of Jena, Germany, introduced the first prototype planetarium in the fall of 1923. By 1933, there were a dozen planetaria in Germany alone, and nearly a dozen more abroad. This talk argues that on one hand, Zeiss saw the planetarium as an opportunity to reintroduce German engineering to a skeptical international market. On the other, Zeiss recognized that a large part of the planetarium’s domestic appeal lay in the romance of its German origins. Through an examination of Zeiss’ corporate correspondence, propaganda, and contemporary international and domestic press, this talk argues that in advertising the planetarium in Germany and abroad, the Zeiss company relied on competing constructions of a post-war German identity rooted in conflicting understandings of space.

  4. Zeiss ΣIGMA VP-FE-SEM User Guide

    Science.gov (United States)

    User guide for analyzing carbon based nanomaterials on a Zeiss Sigma microscope. The guide includes helpful steps for sample preparation and loading. Specific topics utilizing the scanning electron microscope are instrumentation startup and imagining. A variety of detectors in...

  5. Production, Characterization, and Flocculation Mechanism of Cation Independent, pH Tolerant, and Thermally Stable Bioflocculant from Enterobacter sp. ETH-2

    Science.gov (United States)

    Tang, Wei; Song, Liyan; Li, Dou; Qiao, Jing; Zhao, Tiantao; Zhao, Heping

    2014-01-01

    Synthetic high polymer flocculants, frequently utilized for flocculating efficiency and low cost, recently have been discovered as producing increased risk to human health and the environment. Development of a more efficient and environmentally sound alternative flocculant agent is investigated in this paper. Bioflocculants are produced by microorganisms and may exhibit a high rate of flocculation activity. The bioflocculant ETH-2, with high flocculating activity (2849 mg Kaolin particle/mg ETH-2), produced by strain Enterobacter sp. isolated from activated sludge, was systematically investigated with regard to its production, characterization, and flocculation mechanism. Analyses of microscopic observation, zeta potential and ETH-2 structure demonstrates the bridging mechanism, as opposed to charge neutralization, was responsible for flocculation of the ETH-2. ETH-2 retains high molecular weight (603 to 1820 kDa) and multi-functional groups (hydroxyl, amide and carboxyl) that contributed to flocculation. Polysaccharides mainly composed of mannose, glucose, and galactose, with a molar ratio of 1∶2.9∶9.8 were identified as the active constituents in bioflocculant. The structure of the long backbone with active sites of polysaccharides was determined as a primary basis for the high flocculation activity. Bioflocculant ETH-2 is cation independent, pH tolerant, and thermally stable, suggesting a potential fit for industrial application. PMID:25485629

  6. Production, characterization, and flocculation mechanism of cation independent, pH tolerant, and thermally stable bioflocculant from Enterobacter sp. ETH-2.

    Directory of Open Access Journals (Sweden)

    Wei Tang

    Full Text Available Synthetic high polymer flocculants, frequently utilized for flocculating efficiency and low cost, recently have been discovered as producing increased risk to human health and the environment. Development of a more efficient and environmentally sound alternative flocculant agent is investigated in this paper. Bioflocculants are produced by microorganisms and may exhibit a high rate of flocculation activity. The bioflocculant ETH-2, with high flocculating activity (2849 mg Kaolin particle/mg ETH-2, produced by strain Enterobacter sp. isolated from activated sludge, was systematically investigated with regard to its production, characterization, and flocculation mechanism. Analyses of microscopic observation, zeta potential and ETH-2 structure demonstrates the bridging mechanism, as opposed to charge neutralization, was responsible for flocculation of the ETH-2. ETH-2 retains high molecular weight (603 to 1820 kDa and multi-functional groups (hydroxyl, amide and carboxyl that contributed to flocculation. Polysaccharides mainly composed of mannose, glucose, and galactose, with a molar ratio of 1:2.9:9.8 were identified as the active constituents in bioflocculant. The structure of the long backbone with active sites of polysaccharides was determined as a primary basis for the high flocculation activity. Bioflocculant ETH-2 is cation independent, pH tolerant, and thermally stable, suggesting a potential fit for industrial application.

  7. Experience in use of optical theodolite for machine construction

    Science.gov (United States)

    Shereshevskiy, L. M.

    1984-02-01

    An optical theodolite, an instrument of small size and weight featuring a high-precision horizontal dial, was successfully used in production of forging and pressing equipment at the Voronezh plant. Such a TV-1 theodolite, together with a contact-type indicating device and a mechanism for centering the machined part, is included in a turret goniometer for angular alignment and control of cutting operations. Its micrometer has 1 inch scale divisions, the instrument is designed to give readings with a high degree of stability and reproducibility with the standard deviation of one measurement not exceeding 5 inches. It is particularly useful in production of parts with variable spacing and cross section of grooves or slots, including curvilinear ones. With a universal adapter plate on which guide prisms and an interchangeable gauge pin are mounted, this theodolite can also be used in production of large bevel gears: the same instrument for a wide range of gear sizes, diametral pitches, and tooth profiles. Using the maximum of standard components, this theodolite can be easily assembled at any manufacturing plant.

  8. Study on the calibration and optimization of double theodolites baseline

    Science.gov (United States)

    Ma, Jing-yi; Ni, Jin-ping; Wu, Zhi-chao

    2018-01-01

    For the double theodolites measurement system baseline as the benchmark of the scale of the measurement system and affect the accuracy of the system, this paper puts forward a method for calibration and optimization of the double theodolites baseline. Using double theodolites to measure the known length of the reference ruler, and then reverse the baseline formula. Based on the error propagation law, the analyses show that the baseline error function is an important index to measure the accuracy of the system, and the reference ruler position, posture and so on have an impact on the baseline error. The optimization model is established and the baseline error function is used as the objective function, and optimizes the position and posture of the reference ruler. The simulation results show that the height of the reference ruler has no effect on the baseline error; the posture is not uniform; when the reference ruler is placed at x=500mm and y=1000mm in the measurement space, the baseline error is the smallest. The experimental results show that the experimental results are consistent with the theoretical analyses in the measurement space. In this paper, based on the study of the placement of the reference ruler, for improving the accuracy of the double theodolites measurement system has a reference value.

  9. CCD Camera Lens Interface for Real-Time Theodolite Alignment

    Science.gov (United States)

    Wake, Shane; Scott, V. Stanley, III

    2012-01-01

    Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.

  10. Computer Simulation of Angle-measuring System of Photoelectric Theodolite

    International Nuclear Information System (INIS)

    Zeng, L; Zhao, Z W; Song, S L; Wang, L T

    2006-01-01

    In this paper, a virtual test platform based on malfunction phenomena is designed, using the methods of computer simulation and numerical mask. It is used in the simulation training of angle-measuring system of photoelectric theodolite. Actual application proves that this platform supplies good condition for technicians making deep simulation training and presents a useful approach for the establishment of other large equipment simulation platforms

  11. A novel calibration method for non-orthogonal shaft laser theodolite measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Bin, E-mail: wubin@tju.edu.cn, E-mail: xueting@tju.edu.cn; Yang, Fengting; Ding, Wen [State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072 (China); Xue, Ting, E-mail: wubin@tju.edu.cn, E-mail: xueting@tju.edu.cn [College of Electrical Engineering and Automation, Tianjin Key Laboratory of Process Measurement and Control, Tianjin University, Tianjin 300072 (China)

    2016-03-15

    Non-orthogonal shaft laser theodolite (N-theodolite) is a new kind of large-scale metrological instrument made up by two rotary tables and one collimated laser. There are three axes for an N-theodolite. According to naming conventions in traditional theodolite, rotary axes of two rotary tables are called as horizontal axis and vertical axis, respectively, and the collimated laser beam is named as sight axis. And the difference between N-theodolite and traditional theodolite is obvious, since the former one with no orthogonal and intersecting accuracy requirements. So the calibration method for traditional theodolite is no longer suitable for N-theodolite, while the calibration method applied currently is really complicated. Thus this paper introduces a novel calibration method for non-orthogonal shaft laser theodolite measurement system to simplify the procedure and to improve the calibration accuracy. A simple two-step process, calibration for intrinsic parameters and for extrinsic parameters, is proposed by the novel method. And experiments have shown its efficiency and accuracy.

  12. Prvi optički teodoliti : First optical theodolites

    Directory of Open Access Journals (Sweden)

    Nedim Tuno

    2011-12-01

    Full Text Available U radu je dat pregled prvih optičkih teodolita, koji su označili veliku prekretnicu u razvoju i primjeni geodetskih instrumenata. Njihova pojava veže se za ime čuvenog konstruktora Heinricha Wilda i imala je nemjerljivo pozitivan uticaj na cjelokupnu industriju geodetskih instrumenata, koji se osjeća čak i danas. Svrha članka nije komercijalna u smislu reklamiranja pojedinih tehničkih rješenja iz tvornice Wild (Leica, već pokušaj da se prikaže mjerna tehnologija koja je dominirala u prethodnom stoljeću, kroz prizmu legendarnog teodolita T2. : The article gives an overview of the first optical theodolites, which marked a major milestone in the development and use of surveying instruments. Their appearance is connected to the name of the famous constructor Heinrich Wild and had a immeasurably positive impact on the entire industry of surveying instruments, that is still felt today. The purpose of the article is not commercial in terms of advertising of certain technical solutions of the manufacturer Wild (Leica, but an attempt to show the measurement technology that has dominated the previous century, through the lens of legendary T2 theodolite.

  13. Reflector automatic acquisition and pointing based on auto-collimation theodolite

    Science.gov (United States)

    Luo, Jun; Wang, Zhiqian; Wen, Zhuoman; Li, Mingzhu; Liu, Shaojin; Shen, Chengwu

    2018-01-01

    An auto-collimation theodolite (ACT) for reflector automatic acquisition and pointing is designed based on the principle of autocollimators and theodolites. First, the principle of auto-collimation and theodolites is reviewed, and then the coaxial ACT structure is developed. Subsequently, the acquisition and pointing strategies for reflector measurements are presented, which first quickly acquires the target over a wide range and then points the laser spot to the charge coupled device zero position. Finally, experiments are conducted to verify the acquisition and pointing performance, including the calibration of the ACT, the comparison of the acquisition mode and pointing mode, and the accuracy measurement in horizontal and vertical directions. In both directions, a measurement accuracy of ±3″ is achieved. The presented ACT is suitable for automatic pointing and monitoring the reflector over a small scanning area and can be used in a wide range of applications such as bridge structure monitoring and cooperative target aiming.

  14. Alignment of Ion Accelerator for Surface Analysis using Theodolite and Laser Tracker

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Tae Sung; Seo, Dong Hyuk; Kim, Dae Il; Kim, Han Sung; Kwon, Hyeok Jung; Cho, Yong Sub [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The method of ion accelerator alignment is used two ways which are a theodolite and laser tracker. For the alignment and maintenance of the proton linear accelerator, the laser tracker is typically used at KOMAC. While the device for alignment by using laser tracker is not installed in all ion accelerator components, it was used in parallel in two methods. In this paper, alignment methods are introduced and the result and comparison of each alignment method are presented. The ion accelerator for surface analysis has aligned using theodolite and laser tracker. The two ways for alignment have advantage as well as weakness. But alignment using laser tracker is stronger than using theodolite. Because it is based on alignment and position data and it is more detailed. Also since the beam distribution is smaller than accelerator component that is direction of beam progress, main component (ex. Magnet, Chamber, Pelletron tank, etc.) alignment using laser tracker is enough to align the ion accelerator.

  15. Horizontal scale calibration of theodolites and total station using a gauge index table

    International Nuclear Information System (INIS)

    Vieira, L H B; Filho, W L O; Barros, W S

    2015-01-01

    This paper shows a methodology to calibrate the horizontal scale of theodolites and total station using a high accuracy index table. The calibration pursued the method of circular scales and precision polygons (also called Rosette Method [1] or multistep). This method consists in the angle comparison of two circular divisions in all relative positions possibilities. Index table errors and theodolite horizontal scale errors were obtained using the method of least squares which is used to process the data from Rosette Method. An experimental setup was used to evaluate this methodology and the details of the mechanical assembly are also described in this paper. Several theodolites and total stations were calibrated using the proposed system and the results infer that the method is suitable to calibrate the different models available in the market. The system showed good stability over time with measurements uncertainties around 1' (one second) depending on instrument features. (paper)

  16. Object recognition with video-theodolites and without targeting the object

    International Nuclear Information System (INIS)

    Kahmen, H.; Seixas, A. de

    1999-01-01

    At the Department of Applied Geodesy and Engineering Geodesy (TU Vienna) an new kind of theodolite measurement system is under development, enabling measurements with an accuracy of 1:30.000 with and without targeting the object. The main goal is, to develop an intelligent multi-sensor system. Thus an operator is only needed to supervise the system. Results are gained on-sine and can be stored in a CAD system. If no artificial targets are used identification of points has to be performed by the Master-Theodolite. The method, used in our project, is based on interest operators. The Slave-Theodolite has to track the master by searching for homologous regions. The before described method can only be used, if there is some texture on the surface of the object. If that is not fulfilled, a 'grid-line-method' can be used, to get informations about the surface of the object. In the case of a cartesian co-ordinate system, for instance, the grid-lines can be chosen by the operator before the measurement process is started. The theodolite-measurement system is then able to detect the grid-lines and to find the positions where the grid-lines intersect the surface of the object. This system could be used for positioning the different components of a particle accelerator. (author)

  17. Object recognition with video-theodolites and without targeting the object

    Energy Technology Data Exchange (ETDEWEB)

    Kahmen, H.; Seixas, A. de [University of Technology Vienna, Institute of Geodesy and Geophysics, Vienna (Austria)

    1999-07-01

    At the Department of Applied Geodesy and Engineering Geodesy (TU Vienna) an new kind of theodolite measurement system is under development, enabling measurements with an accuracy of 1:30.000 with and without targeting the object. The main goal is, to develop an intelligent multi-sensor system. Thus an operator is only needed to supervise the system. Results are gained on-sine and can be stored in a CAD system. If no artificial targets are used identification of points has to be performed by the Master-Theodolite. The method, used in our project, is based on interest operators. The Slave-Theodolite has to track the master by searching for homologous regions. The before described method can only be used, if there is some texture on the surface of the object. If that is not fulfilled, a 'grid-line-method' can be used, to get informations about the surface of the object. In the case of a cartesian co-ordinate system, for instance, the grid-lines can be chosen by the operator before the measurement process is started. The theodolite-measurement system is then able to detect the grid-lines and to find the positions where the grid-lines intersect the surface of the object. This system could be used for positioning the different components of a particle accelerator. (author)

  18. Debris flow cartography using differential GNSS and Theodolite measurements

    Science.gov (United States)

    Khazaradze, Giorgi; Guinau, Marta; Calvet, Jaume; Furdada, Gloria; Victoriano, Ane; Génova, Mar; Suriñach, Emma

    2016-04-01

    The presented results form part of a CHARMA project, which pursues a broad objective of reducing damage caused by uncontrolled mass movements, such as rockfalls, snow avalanches and debris flows. Ultimate goal of the project is to contribute towards the establishment of new scientific knowledge and tools that can help in the design and creation of early warning systems. Here we present the specific results that deal with the application of differential GNSS and classical geodetic (e.g. theodolite) methods for mapping debris and torrential flows. Specifically, we investigate the Portainé stream located in the Pallars Sobirà region of Catalonia (Spain), in the eastern Pyrenees. In the last decade more than ten debris-flow type phenomena have affected the region, causing considerable economic losses. Since early 2014, we have conducted several field campaigns within the study area, where we have employed a multi-disciplinary approach, consisting of geomorphological, dendro-chronological and geodetic methods, in order to map the river bed and reconstruct the history of the extreme flooding and debris flow events. Geodetic studies included several approaches, using the classical and satellite based methods. The former consisted of angle and distance measurements between the Geodolite 502 total station and the reflecting prisms placed on top of the control points located within the riverbed. These type of measurements are precise, although present several disadvantages such as the lack of absolute coordinates that makes the geo-referencing difficult, as well as a relatively time-consuming process that involves two persons. For this reason, we have also measured the same control points using the differential GNSS system, in order to evaluate the feasibility of replacing the total station measurements with the GNSS. The latter measuring method is fast and can be conducted by one person. However, the fact that the study area is within the riverbed, often below the trees

  19. Double-theodolite measurement system used in the image calibration of space photographic instrument

    Institute of Scientific and Technical Information of China (English)

    LI Yan; QIAO Yan-feng; SU Wan-xin; LIU Ze-xun

    2005-01-01

    The purpose of characterizing the image of space photographic instrument is to gain the space included angles from three coordinate axes in the three-dimensional coordinate of the image and the directionality of the three axes of coordinate in the frame of axes of the instrument. The two reference frames will keep in the same direction finally by adjusting according to space angles. This problem was solved by a new high-precision measurement system composed of a double-theodolite and a set of communication system. In the survey system, two TDA5005 total stations from Leica Company will be selected as the double-theodolite and the interdependence of both coordinate systems can be achieved by moving the stations only at one time. Therefore, this measurement system provides a highly efficient and high-precision surveying method to the image calibration of the space photographic instrument. According to the experiment, its measuring accuracy can reach arc-second level.

  20. Automatic Measurement in Large-Scale Space with the Laser Theodolite and Vision Guiding Technology

    Directory of Open Access Journals (Sweden)

    Bin Wu

    2013-01-01

    Full Text Available The multitheodolite intersection measurement is a traditional approach to the coordinate measurement in large-scale space. However, the procedure of manual labeling and aiming results in the low automation level and the low measuring efficiency, and the measurement accuracy is affected easily by the manual aiming error. Based on the traditional theodolite measuring methods, this paper introduces the mechanism of vision measurement principle and presents a novel automatic measurement method for large-scale space and large workpieces (equipment combined with the laser theodolite measuring and vision guiding technologies. The measuring mark is established on the surface of the measured workpiece by the collimating laser which is coaxial with the sight-axis of theodolite, so the cooperation targets or manual marks are no longer needed. With the theoretical model data and the multiresolution visual imaging and tracking technology, it can realize the automatic, quick, and accurate measurement of large workpieces in large-scale space. Meanwhile, the impact of artificial error is reduced and the measuring efficiency is improved. Therefore, this method has significant ramification for the measurement of large workpieces, such as the geometry appearance characteristics measuring of ships, large aircraft, and spacecraft, and deformation monitoring for large building, dams.

  1. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Science.gov (United States)

    Brunke, Heinz-Peter; Matzka, Jürgen

    2018-01-01

    At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer). Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination) measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996).We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters) of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017).

  2. Numerical evaluation of magnetic absolute measurements with arbitrarily distributed DI-fluxgate theodolite orientations

    Directory of Open Access Journals (Sweden)

    H.-P. Brunke

    2018-01-01

    Full Text Available At geomagnetic observatories the absolute measurements are needed to determine the calibration parameters of the continuously recording vector magnetometer (variometer. Absolute measurements are indispensable for determining the vector of the geomagnetic field over long periods of time. A standard DI (declination, inclination measuring scheme for absolute measurements establishes routines in magnetic observatories. The traditional measuring schema uses a fixed number of eight orientations (Jankowski et al., 1996.We present a numerical method, allowing for the evaluation of an arbitrary number (minimum of five as there are five independent parameters of telescope orientations. Our method provides D, I and Z base values and calculated error bars of them.A general approach has significant advantages. Additional measurements may be seamlessly incorporated for higher accuracy. Individual erroneous readings are identified and can be discarded without invalidating the entire data set. A priori information can be incorporated. We expect the general method to also ease requirements for automated DI-flux measurements. The method can reveal certain properties of the DI theodolite which are not captured by the conventional method.Based on the alternative evaluation method, a new faster and less error-prone measuring schema is presented. It avoids needing to calculate the magnetic meridian prior to the inclination measurements.Measurements in the vicinity of the magnetic equator are possible with theodolites and without a zenith ocular.The implementation of the method in MATLAB is available as source code at the GFZ Data Center Brunke (2017.

  3. Mathematical pointing model establishment of the visual tracking theodolite for satellites in two kinds of observation methods.

    Science.gov (United States)

    Zhang, Yuncheng

    The mathematical pointing model is establishment of the visual tracking theodolite for satellites in two kinds of observation methods at Yunnan Observatory, which is related to the digitalisation reform and the optical-electronic technique reform, is introduced respectively in this paper.

  4. Theodolite Polar measurements system and definition of the grid-lines method

    Directory of Open Access Journals (Sweden)

    Andréa de Seixas

    2004-12-01

    Full Text Available The requirements of construction quality, mainly in the car and airplane industries, accelerate the development of new 3D-Measurement Systems and Measurement Processes that make possible the automatic object recording and it’s post-processing on the basis, for example, on deformations. The geometrical reconstruction of objects or surface requires a minimal number of points, which abstracts and will be fulfill through interpolation its exact form and quality of the object in each case. The applications of the laser for the active signalization of a point object in combination with the directional measurement make possible in such way the determination of objects or surfaces, including also, places where the use of artificial targets is dangerous or impossible. This work describes the development of such measurement system based on two measurement robots or a reflector-free measuring tachymeter. The system is capable of reaching the intersections points of a grid-line that is defined in an appropriate coordinate system. The aim of this paper is to present the development of measurement methods that can reconstruct unknown three-dimensional and not signalized objects. The existing deformation-measurement, based on Pointer Theodolite and a Video Theodolite Measurement System and the other reflector-free Tachymeter Measurement System in context with the problematic analysis of deformation will be presented. The grid-lines Methods appear a solution and stand as new alternative for the geometrical reconstruction of the object surfaces. Its definition and preparations in a suitable coordinate system are discussed in detail.

  5. Comparing the Zeiss Callisto Eye and the Alcon Verion Image Guided System Toric Lens Alignment Technologies.

    Science.gov (United States)

    Hura, Arjan S; Osher, Robert H

    2017-07-01

    To compare the alignment meridian generated by the Zeiss Callisto Eye (Carl Zeiss AG, Dublin, CA) and the Alcon Verion Image Guided System (Alcon Laboratories, Inc., Fort Worth, TX). In this retrospective comparative evaluation of technology, intraoperative images were captured at different steps in the same surgery, allowing the comparison of the guidance lines generated by the Verion system to the parallel guidance lines generated by the Callisto Eye system. Measurements of each hemi-meridian were quantified using Adobe Photoshop 2015 CC software (Adobe Systems, San Jose, CA). The numbers of degrees separating these alignment meridians were calculated, entered into a database, and analyzed. The authors found that of 98 captured images of 16 eyes, the two technologies were identical in 0 eyes (θ 1 = θ 2 = 0), similar by 3° in 52 (53%) captured images (θ 1 ≠ θ 2 ≠ 0), and different by at least 3° in 46 (47%) captured images (θ 1 ≠ θ 2 ≠ 0). The target meridians were superimposed, the target lines were minimally separated, and the target lines were dissimilar. It was noted that some intraoperative variation occurred from measurement to measurement. Within the small group of 16 cases of routine toric lens implantation in this study, the absolute average number of degrees of misalignment between the Verion and Callisto Eye systems was 3.355 for θ 1 and 3.838 for θ 2 . On average, the intraoperative variation termed "drift" was noted to be 3.963° for θ 1 , and 4.557° for θ 2 . The authors found that small deviations were frequent when comparing two sophisticated technologies. Although deviations greater than 3° occurred in less than 47% of captured images from 16 eyes, smaller but significant variations of less than 3° occurred in 53% of captured images from 16 eyes. It was rare to identify a large deviation. However, the authors identified "drift" in the same eye when measurements were taken at different times. The results indicate that the two

  6. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    Science.gov (United States)

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p ultrasound, respectively (p power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  7. Avaliação do desempenho visual da lente intraocular difrativa multifocal - Zeiss AT Lisa 809 MTM

    Directory of Open Access Journals (Sweden)

    Lucas Monferrari Monteiro Vianna

    2014-04-01

    Full Text Available Objetivo: Avaliar a função visual dos pacientes com implante bilateral da LIO multifocal difrativa AT-Lisa 809 MTM por meio dos exames de acuidade visual com e sem correção óptica, curva de sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF39. Métodos: Estudo clínico, prospectivo e de intervenção, que avaliou os resultados de 20 olhos de 10 pacientes, submetidos à facoemulsificação e implante de LIO, entre fevereiro e junho de 2012. Resultados: A ametropia residual média pós-operatória foi de 0,05 ± 0,42 (-0,75 a +1,25 D dioptrias esféricas e -0,30 ± 0,42 (0 a -1,25 D dioptrias cilíndricas. Na curva de desenfoque mono e binocular, a melhor acuidade visual média obtida com 0.00 D de desenfoque (AV de longe. O segundo pico foi obtido com desenfoque de -3,00 D, o que equivale à visão de perto a 33 cm. Entre esses picos, observamos uma perda de desempenho visual, com desenfoque de -2,00 D, que equivale a visão intermediária a 50 cm. A sensibilidade ao contraste foi similar aos relatados na literatura com este tipo de LIO, tanto com quanto sem ofuscamento, e é mostrada em gráficos. O questionário de função visual (VFQ-39 teve valor médio de 91,91 +- 6,82. Conclusão: A LIO multifocal difrativa AT-Lisa 809MTM (Carl Zeiss Meditec Company - Alemanha apresentou resultados condizentes com a literatura quando avaliada pelos exames de acuidade visual com e sem correção óptica, sensibilidade ao contraste, curva de desfoco e questionário de qualidade de função visual (VQF 39.

  8. Automatic grid azimuth by hour angle of the sun, a star or a planet using an electronic theodolite Kern E2

    Science.gov (United States)

    Solaric, Nikola

    1991-03-01

    The paper describes a procedure for automatic determinations of the grid azimuth of an object on the earth surface by the hour angle of a celestial object (the sun, a star, or a planet), using the electronic theodolite Kern E2. The observation procedure is simple because the electronic calculator is directing the procedure, and the degree of accuracy is immediately determined. With this method, the external rms error of a single set is approximately two times smaller than in the case of the altitude method. The paper includes a flowchart of the program.

  9. Agile machining and inspection thrust area team-on-machine probing / compatibility assessment of Parametric Technology Corporation (PTC) pro/CMM DMIS with Zeiss DMISEngine.

    Energy Technology Data Exchange (ETDEWEB)

    Wade, James Rokwel; Tomlinson, Kurt; Bryce, Edwin Anthony

    2008-09-01

    The charter goal of the Agile Machining and Inspection Thrust Area Team is to identify technical requirements, within the nuclear weapons complex (NWC), for Agile Machining and Inspection capabilities. During FY 2008, the team identified Parametric Technology Corporation (PTC) Pro/CMM as a software tool for use in off-line programming of probing routines--used for measurement--for machining and turning centers. The probing routine would be used for in-process verification of part geometry. The same Pro/CMM program used on the machine tool could also be employed for program validation / part verification using a coordinate measuring machine (CMM). Funding was provided to determine the compatibility of the Pro/CMM probing program with CMM software (Zeiss DMISEngine).

  10. Reproducibility of disc and macula optical coherence tomography using the Canon OCT-HS100 as compared with the Zeiss Cirrus HD-OCT.

    Science.gov (United States)

    Brautaset, Rune; Birkeldh, Ulrika; Rosén, Rebecka; Ramsay, Marika Wahlberg; Nilsson, Maria

    2014-01-01

    In a clinical setting, the usefulness of optical coherence tomography (OCT) is strongly dependent on reproducibility of the measurement. The aim of the present study was to evaluate macula and optic disc measurement reproducibility with the new spectral-domain OCT (SD-OCT) from Canon (Canon OCT-HS100) and to compare reproducibility and obtained measurements with the Zeiss Cirrus HD-OCT. Macula and optic disc parameters from the right eyes of 31 subjects were obtained twice with both instruments. Interoperator reproducibility was evaluated by use of the coefficient of repeatability (CR), and the obtained measurements were compared between the instruments. No difference in interoperator reproducibility could be found when comparing the 2 instruments and reproducibility ranged from 3.94% to 12.77% for optic disc parameters and from 1.19% to 3.54% for macula parameters. The lowest reproducibility was found for cup volume and vertical cup/disc ratio with both instruments. For all macula and retinal nerve fiber layer (RNFL) thickness measurements, there was a statistical difference when comparing the 2 instruments, except for RFNL measurements of the superior quadrant, with the Canon OCT-HS100 always evaluating the thickness to be thicker; however, the 2 instruments correlated well. The Canon OCT-HS100 is a reproducible instrument that matches the Zeiss Cirrus HD-OCT well. It remains to be evaluated how sensitive the Canon OCT-HS100 is to detect small subtle changes in optic disc parameters and macular nerve fiber layer thickness. Furthermore, due to the differences in thickness estimation, it is important to emphasize that SD-OCTs are not interchangeable.

  11. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University -- Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  12. Acquisition of an Electron Back Scatter Diffraction (EBSD) system for the Zeiss Sigma SEM at Portland State University Planetary Major Equipment

    Science.gov (United States)

    Ruzicka, Alex

    To build on our parent Origins program award, entitled "Shock histories of chondrites as revealed by combined microstructural (TEM), petrographic, and X-ray microtomographic (micro-CT) analysis", we are requesting as Planetary Major Equipment the acquisition of an Electron Back Scatter Diffraction (EBSD) system, which will integrate with a Zeiss Sigma SEM that was installed at Portland State University last year (2010). This EBSD system will greatly augment the science return of the parent grant by allowing quantitative measurements of strain and textural fabrics in grains of all sizes and types across an entire thin section. Such measurements will help link data that are already being obtained with optical light microscopy, transmission electron microscopy, and micro- tomography methods. More generally, the EBSD system will augment the PI's research on the petrology of extraterrestrial materials by providing an additional tool for petrographic analyses, with data that can be used to evaluate strain, grain orientations, grain size distributions, phase proportions, and mineralogy. The equipment will enable quantitative characterization of the crystallography of primitive extraterrestrial materials, which will contribute to a better understanding of the formation and evolution of planetary systems, a major goal of NASA.

  13. EELS data acquisition, processing and display for the Zeiss CEM 902 based on LOTUS 1-2-3: application examples from a biological system and inorganic transition metal compounds.

    Science.gov (United States)

    Drechsler, M; Cantow, H J

    1991-04-01

    A personal computer combined with LOTUS 1-2-3 software, including the RS232 module of LOTUS MEASURE and a 12-bit ADC, has been used for data acquisition of electron energy-loss spectroscopy (EELS) spectra with the Zeiss CEM 902. The internal macro language of LOTUS 1-2-3 allows a menu-driven procedure. Macro-programs partly combined with external FORTRAN programs can be chosen from the menu for background subtraction, removal of multiple scattering effects by deconvolution, elemental quantification and several utilities. For special applications or conditions the macro programs can easily be modified. Spectra from crystals of two inorganic transition metal compounds, ruthenium trichloride and vanadium disulphide, and from a biological sample are presented as examples of the application of this software.

  14. Automatization Project for the Carl-Zeiss-Jena Coudè Telescope of the Simón Bolívar Planetarium I. The Electro-Mechanic System

    Science.gov (United States)

    Núñez, A.; Maharaj, A.; Muñoz, A. G.

    2009-05-01

    The ``Complejo Científico, Cultural y Turístico Simón Bolívar'' (CCCTSB), located in Maracaibo, Venezuela, lodges the Simón Bolívar Planetarium and an 150 mm aperture, 2250 mm focal length Carl-Zeiss-Jena Coudè refractor telescope. In this work we discuss the schematics for the automatization project of this Telescope, the planned improvements, methodology, engines, micro-controllers, interfaces and the uptodate status of the project. This project is working on the first two levels of the automation pyramid, the sensor -- actuator level and the control or Plant floor level. The Process control level correspond to the software related section. This mean that this project work immediately with the electrical, electronic and mechanical stuffs, and with the assembler micro controller language. All the pc related stuff, like GUI (Graphic user interfaces), remote control, Grid database, and others, correspond to the next two automation pyramid levels. The idea is that little human intervention will be required to manipulate the telescope, only giving a pair of coordinates to ubicate and follow an object on the sky. A set of three servomotors, coupling it with the telescope with a gear box, are going to manipulate right ascension, declination and focus movement. For the dome rotation, a three phase induction motor will be used. For dome aperture/closure it is suggested a DC motor powered with solar panels. All those actuators are controlled by a 8 bits micro-controller, which receive the coordinate imput, the signal from the position sensors and have the PID control algorithm. This algorithm is tuned based on the mathematical model of the telescope electro-mechanical instrumentation.

  15. Study of CCD Eyepiece on T-4 Theodolite.

    Science.gov (United States)

    1982-11-01

    11. REVIEW OF TWO-COLOR REFRACTOMETRY OBJECTIVES .....................3 III, ACHIEVEMENTS IN TWO- COLOR REFRACTOMETRY DURING THIS CONTRA...indirectly influence the questions of star catalogs. The initial efforts under this contract were addressed toward Two- Color Refractometry . This is a...in the astroposition procedure. Future efforts on other projects will consist of the return to the Two-Color Refractometry to provide a parallel

  16. Measurement of electrostatically formed antennas using photogrammetry and theodolites

    Science.gov (United States)

    Goslee, J. W.; Hinson, W. F.; Kennefick, J. F.; Mihora, D. J.

    1984-01-01

    An antenna concept is presently being evaluated which has extremely low mass and high surface precision for potential depolyment from the Space Shuttle. This antenna concept derives its reflector surface quality from the application of electrostatic forces to tension and form a thin membrane into the desired concave reflector surface. The Shuttle-deployed antenna would have a diameter of 100 meters and an RMS surface smoothness of 10 to 1 mm for operation at 1 to 10 GHz. NASA Langley Research Center (LaRC) has built, and is currently testing, a subscale (1/20 scale) membrane reflector model of such an antenna. Several surface measurement systems were evaluated as part of the experimental surface measuring efforts. The surface measurement systems are addressed as well as some of the preliminary measurement results.

  17. Accuracy of Visante and Zeiss-Humphrey Optical Coherence Tomographers and their cross calibration with optical pachymetry and physical references

    Directory of Open Access Journals (Sweden)

    Jyotsna Maram

    2011-10-01

    Conclusions: Using references lenses with refractive index of the cornea (1.376 allows rapid and simple calibration and cross calibration of instruments for measuring the corneal thickness. The Visante and OCT II do not produce measurements that are equal to physical references with refractive index equal to the human cornea.

  18. Comparison of the biometric measurements calculated with Zeiss IOL-Master and WaveLight OB-820

    Directory of Open Access Journals (Sweden)

    Labiris G

    2017-04-01

    Full Text Available Georgios Labiris,1,2 Panagiota Ntonti,2 Konstantinos Ntitsos,2 Andreas Katsanos,2 Haris Sideroudi,2 Vasilios Kozobolis1,2 1Department of Ophthalmology, University Hospital of Alexandroupolis, 2Eye Institute of Thrace, Alexandroupolis, Greece Background: The primary objective of this study was to investigate the level of agreement between IOL-Master and OB-820 ocular biometers.Materials and methods: In this prospective randomized case series, we measured the anterior chamber depth (ACD, the axial length (AL, the corneal radii (R1, R2, the ratio of mean corneal radius and spherical equivalent and the corneal astigmatism (cylinder [Cyl] before and after cataract extraction surgery.Results: Significant differences between pre- and postoperative data were observed for ACD for both biometric devices (P<0.01 and Cyl parameter in IOL-Master. Range and 95% limits of agreement (LoA were clinically significantly different for AL parameter pre- and postoperatively and for R2 and radius and spherical equivalent postoperatively (P<0.001. The rest of the parameters presented sufficient 95% LoA, which imply good agreement.Conclusion: In clinical practice, the IOL-master and OB-820 should not be used interchangeably due to discrepancy in the important AL parameter. Both biometers may provide consistent results regarding Cyl, ACD and R1. Keywords: cataract, IOL-Master, OB-820, biometry, level of agreement

  19. Data from theodolite measurements of creep rates on San Francisco Bay region faults, California, 1979-2012

    Science.gov (United States)

    McFarland, Forrest S.; Lienkaemper, James J.; Caskey, S. John

    2009-01-01

    Our purpose is to annually update our creep-data archive on San Francisco Bay region active faults for use by the scientific research community. Earlier data (1979-2001) were reported in Galehouse (2002) and were analyzed and described in detail in a summary report (Galehouse and Lienkaemper, 2003). A complete analysis of our earlier results obtained on the Hayward Fault was presented in Lienkaemper, Galehouse and Simpson (2001) and updated in Lienkaemper and others (2012). Lienkaemper and others (2014a) provide a new overview and analysis of fault creep along all sections of the northern San Andreas Fault system, from which they estimate by how much fault creep reduces the seismic hazard for each fault section.

  20. Hungarian repeat station survey, 2010

    Directory of Open Access Journals (Sweden)

    Péter Kovács

    2013-03-01

    Full Text Available The last Hungarian repeat station survey was completed between October 2010 and February 2011. Declination, inclination and the total field were observed using one-axial DMI fluxgate magnetometer mounted on Zeiss20A theodolite and GSM 19 Overhauser magnetometer. The magnetic elements of the sites were reduced to the epoch of 2010.5 on the basis of the continuous recordings of Tihany Geophysical Observatory. In stations located far from the reference observatory, the observations were carried out in the morning and afternoon in order to decrease the effect of the distant temporal correction. To further increase the accuracy, on-site dIdD variometer has also been installed near the Aggtelek station, in the Baradla cave, during the survey of the easternmost sites. The paper presents the technical details and the results of our last campaign. The improvement of the accuracy of the temporal reduction by the use of the local variometer is also reported.

  1. A battery-operated pilot balloon time-signal generator

    Science.gov (United States)

    Ralph H. Moltzau

    1966-01-01

    Describes the design and construction of a 1-pound, battery-operated, time-signal transmitter, which is usable with portable radio or field telephone circuits for synchronizing multi-theodolite observation of pilot balloons.

  2. The artificial satellite observation chronograph controlled by single chip microcomputer.

    Science.gov (United States)

    Pan, Guangrong; Tan, Jufan; Ding, Yuanjun

    1991-06-01

    The instrument specifications, hardware structure, software design, and other characteristics of the chronograph mounting on a theodolite used for artificial satellite observation are presented. The instrument is a real time control system with a single chip microcomputer.

  3. Rock glacier velocities, Selwyn Mountains, Yukon and NWT, Canada, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — An average of 6 markers were surveyed on each of 15 rock glaciers, once each in 1983 and 1995 using a level (1983) and a theodolite (1995). Measurement error was on...

  4. The Mark II Automatic Diflux

    Directory of Open Access Journals (Sweden)

    Jean L Rasson

    2011-07-01

    Full Text Available We report here on the new realization of an automatic fluxgate theodolite able to perform unattended absolute geomagnetic declination and inclination measurements: the AUTODIF MKII. The main changes of this version compared with the former one are presented as well as the better specifications we expect now. We also explain the absolute orientation procedure by means of a laser beam and a corner cube and the method for leveling the fluxgate sensor, which is different from a conventional DIflux theodolite.

  5. Modelagem numérica da superfície na geração da planialtimetra segundo dados de quatro equipamentos topogríficos

    OpenAIRE

    Gomes, Luciano Nardini [UNESP; Cardoso, Lincoln Gehring [UNESP

    2008-01-01

    The aim of this present work was to compare planialtimetric charts obtained from different risings using two different theodolite types, a total station, and a precision level, used as control. Using a total station, an area was marked with clear variations of relief, following a grid, with a distance of 20 meters among stakes. After that, the stakes were read by the total station and two theodolites of different precisions. The geometric leveling was done by a precision level. The data were ...

  6. Исследование процесса измерения корпусных деталей на координатно-измерительной машине Carl Zeiss Contura g2

    OpenAIRE

    ВАСИЛЬЕВА А.А.; АБЛЯЗ Т.Р.

    2015-01-01

    Развитие технологий невозможно без качественного контроля. Широкое применение станков с числовым программным управлением в производстве увеличило требования к используемым средствам контроля, адекватным ответом стало применение в контроле координатно-измерительных машин (КИМ). Современные КИМ представлены широким модельным рядом, что позволяет выбрать машину в соответствии с решаемыми измерительными задачами, условиями (температура, давление, влажность, запыленность) и финансовыми возможностя...

  7. DI3 - A New Procedure for Absolute Directional Measurements

    Directory of Open Access Journals (Sweden)

    A Geese

    2011-06-01

    Full Text Available The standard observatory procedure for determining a geomagnetic field's declination and inclination absolutely is the DI-flux measurement. The instrument consists of a non-magnetic theodolite equipped with a single-axis fluxgate magnetometer. Additionally, a scalar magnetometer is needed to provide all three components of the field. Using only 12 measurement steps, all systematic errors can be accounted for, but if only one of the readings is wrong, the whole measurement has to be rejected. We use a three-component sensor on top of the theodolites telescope. By performing more measurement steps, we gain much better control of the whole procedure: As the magnetometer can be fully calibrated by rotating about two independent directions, every combined reading of magnetometer output and theodolite angles provides the absolute field vector. We predefined a set of angle positions that the observer has to try to achieve. To further simplify the measurement procedure, the observer is guided by a pocket pc, in which he has only to confirm the theodolite position. The magnetic field is then stored automatically, together with the horizontal and vertical angles. The DI3 measurement is periodically performed at the Niemegk Observatory, allowing for a direct comparison with the traditional measurements.

  8. Southern right whales Eubalaena australis visit the coasts of ...

    African Journals Online (AJOL)

    spamer

    Counts and photographs of right whales Eubalaena australis taken on aerial surveys of the southern coast of. South Africa between ... of 0.08–2.89 km.h-1. Theodolite tracking of undisturbed groups of right whales from Cape Columbine produced ...... right whales on the coast of Argentina (Outer Coast) between 1971 and ...

  9. Measurements of movements of the Perua dam using classic and modern electronic instruments; Erforschung der Verschiebung des Staudammes vom Wasserkraftwerk Peruca mit den klassischen und modernen elektronischen Instrumenten

    Energy Technology Data Exchange (ETDEWEB)

    Bilajbegovic, A [Zagreb Univ. (Croatia). Geodaetische Fakultaet

    1997-12-31

    With the aim of investigating the moving of the power plant Peruca dam body, measurements with the classical precise theodolite WILD T3 as well as the modern electronic instruments, KERN E2 and WILD T2000S, were carried out in order to choose the most suitable instrumentaria. All three instruments were used in measuring with the same number of horizontal angle rounds; by using the statistical tests, a significant accuracy dependency on the used instrument type was established. The most accurate results were obtained by electronic theodolite Wild T2000S (estimated variance factor {sigma}=0.61), then by KERN E2 {sigma}=1.23, and finally by T3 {sigma}=1.68. Likewise, the use of the deformation analysis, i.e. global and local tests, the highest number of significant movements was established by measuring with the WILD T2000S electronic theodolite. The interior accuracy of straight line measurement of the electronic theodolite E2 was investigated in dependence with the number of horizontal angle rounds. Unfortunately, the war in this country is the reason that the planned measurements with the GPS devices have so far not been carried out. (orig.)

  10. Development and application of high-precision metrology for the ATLAS tile-calorimeter construction (pre-assembly experience and lessons)

    International Nuclear Information System (INIS)

    Batusov, V.Yu.; Budagov, Yu.A.; Khubua, D.I.

    2004-01-01

    In view of the forthcoming ATLAS assembly in the pit the pre-assembly of the Hadron Tile Calorimeter BARRELS was undertaken at the laboratory hall. A complex of metrology methods (laser, photogrammetry, theodolite, mechanic, PREDICTION programme) developed at the principal stages and resulted in successful high-precision erection of the barrels has been described

  11. Measurements of movements of the Perua dam using classic and modern electronic instruments; Erforschung der Verschiebung des Staudammes vom Wasserkraftwerk Peruca mit den klassischen und modernen elektronischen Instrumenten

    Energy Technology Data Exchange (ETDEWEB)

    Bilajbegovic, A. [Zagreb Univ. (Croatia). Geodaetische Fakultaet

    1996-12-31

    With the aim of investigating the moving of the power plant Peruca dam body, measurements with the classical precise theodolite WILD T3 as well as the modern electronic instruments, KERN E2 and WILD T2000S, were carried out in order to choose the most suitable instrumentaria. All three instruments were used in measuring with the same number of horizontal angle rounds; by using the statistical tests, a significant accuracy dependency on the used instrument type was established. The most accurate results were obtained by electronic theodolite Wild T2000S (estimated variance factor {sigma}=0.61), then by KERN E2 {sigma}=1.23, and finally by T3 {sigma}=1.68. Likewise, the use of the deformation analysis, i.e. global and local tests, the highest number of significant movements was established by measuring with the WILD T2000S electronic theodolite. The interior accuracy of straight line measurement of the electronic theodolite E2 was investigated in dependence with the number of horizontal angle rounds. Unfortunately, the war in this country is the reason that the planned measurements with the GPS devices have so far not been carried out. (orig.)

  12. Quercetin - A Flavonoid Compound from Sarcopyramis bodinieri var ...

    African Journals Online (AJOL)

    The flavonoid compound was identified as quercetin by 1H-. NMR and ESI-MS ... phenolic compounds were isolated, and their .... scored under a fluorescence microscope (Carl. Zeiss .... Antioxidant Properties of Sarcopyramis bodinieri.

  13. Nematoda: Dorylaimida

    African Journals Online (AJOL)

    1992-04-02

    sedimenta- tion method (Loubser 1985), killed by gentle heat, fixed in. FAA, processed into glycerine by Thome's slow method and mounted on permanent slides. Measurements and draw- ings were made with the aid of a Zeiss ...

  14. Morning Glory Disc Anomaly: A Case Report

    African Journals Online (AJOL)

    Ocular complications in affected eye may include strabismus, retinal detachment and reduced visual acuity. Contralateral ... near acuity was OD J3 and OS J1+ according to Jaeger. ... Using the Automated Humphrey Field analyser (Carl Zeiss.

  15. Micrometer and CCD measurements of double stars (Series 51

    Directory of Open Access Journals (Sweden)

    Popović G.M.

    1998-01-01

    Full Text Available 36 micrometric measurements of 20 double or multiple systems carried out with the Zeiss 65/1055 cm Refractor of Belgrade Observatory are communicated. Also 35 CCD measurements of 15 double or multiple systems are included.

  16. The potential of postharvest silicon dips to regulate phenolics in ...

    African Journals Online (AJOL)

    ACCI

    2013-03-27

    Mar 27, 2013 ... This study investigated the ability of silicon dips to enhance the phenolic content in order to .... observed under a scanning electron microscope equipped with. EDX detector (Zeiss EVO LS15, Oxford XMax detector, and INCA.

  17. Further development of the instrument and technique for photometric evaluation of autoradiograms

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, K; Baumbach, H; Birkholz, W; Kiese, H J [Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung

    1976-01-01

    Analogous and digital techniques for evaluation of autoradiograms are compared and measured for critical evaluation of autoradiograms. Additional instruments to a Zeiss-Photometer for digital and analogous evaluation of autoradiograms are described.

  18. Effect of nanocrystalline surface of substrate on microstructure and ...

    Indian Academy of Sciences (India)

    surface layers or bulk nanocrystalline metals and alloys more effectively. ... severe plastic deformation on surface layers of bulk met- als at high strains and strain rates. .... scanning electron microscopy (SEM) (Zeiss, model: Sigma. VP), energy ...

  19. Childhood Eye Diseases in Bayelsa State, Nigeria: A Tertiary Eye ...

    African Journals Online (AJOL)

    -Streit) and a posterior segement examination using a direct and indirect ophthalmoscopes (KeelerR) as necessary. Those requiring refraction was sent to the optometrist. Objective refraction was done using a Carl Zeiss 599 autorefractometer ...

  20. Mechanisms of antibacterial activity and stability of silver ...

    Indian Academy of Sciences (India)

    using scanning electron microscopy revealed that the size and surface density of AgNPs grown by the photoreduc- tion of silver ... doped TiO2 nanosheet films against S. aureus and E. coli in the dark .... Zeiss) with an attached Axiovert 200M (Zeiss) inverted flu- ... SEM imaging of TiO2 and AgNPs/TiO2 coatings as well as.

  1. The Oviduct and Serous Cancer Risk Assessment

    Science.gov (United States)

    2016-10-01

    genes deregulated in putative stem cells (Yamamoto et al) has been made public. Page 4 What was the impact on society beyond science and...Interline CCD camera and NIS-Elements Advanced Research v.4.13 software (Nikon, Japan) or an LSM 780 confocal microscope (Carl Zeiss, Germany ) with LSM...Carl Zeiss, Germany ) and each selected cell population from different slides of the same patient was pooled. Total RNAs were extracted using the Pico

  2. Preclinical Validation of Anti-Nuclear Factor Kappa B Therapy against Vestibular Schwannoma and Neurofibromatosis Type II

    Science.gov (United States)

    2015-06-01

    Thomsen, J., Nielsen, F.C., 2010. Deregulated genes in sporadic vestibular schwannomas. Otol. Neurotol. 31 (2), 256e266. Cioffi, J.A., Yue, W.Y., Mendolia...Thomas, R., Gope, M.L., Doddaballapur, S.K., Gope, R., 2006. Age dependent phosphorylation and deregulation of p53 in human vestibular schwannomas. Mol...tissue was visualized and imaged using a Carl Zeiss 2000 upright microscope (Carl Zeiss, Jena, Germany ). Schwann and schwannoma cell isolation and

  3. Dimensional measuring techniques in the automotive and aircraft industry

    Science.gov (United States)

    Muench, K. H.; Baertlein, Hugh

    1994-03-01

    Optical tooling methods used in industry are rapidly being replaced by new electronic sensor techniques. The impact of new measuring technologies on the production process has caused major changes on the industrial shop floor as well as within industrial measurement systems. The paper deals with one particular industrial measuring system, the manual theodolite measuring system (TMS), within the aircraft and automobile industry. With TMS, setup, data capture, and data analysis are flexible enough to suit industry's demands regarding speed, accuracy, and mobility. Examples show the efficiency and the wide range of TMS applications. In cooperation with industry, the Video Theodolite System was developed. Its origin, functions, capabilities, and future plans are briefly described. With the VTS a major step has been realized in direction to vision systems for industrial applications.

  4. Engineering surveying theory and examination problems for students

    CERN Document Server

    Schofield, W

    2013-01-01

    Engineering Surveying: Theory and Examination Problems for Students, Volume 1, Third Edition discusses topics concerning engineering surveying techniques and instrumentations. The book is comprised of eight chapters that cover several concerns in engineering survey. Chapter 1 discusses the basic concepts of surveying. Chapter 2 deals with simple and precise leveling, while Chapter 3 covers earthworks. The book also talks about the theodolite and its applications, and then discusses optical distance measurement. Curves, underground and hydrographic surveying, and aspects of dimensional control

  5. Seismic Motion Stability, Measurement and Precision Control.

    Science.gov (United States)

    1979-12-01

    azimuth reference used for precision alignment of test fixtures and components is a porro prism mounted within the inner labora- tory. The orientation of...14 6.2 Low Frequency Tilt Loop. .................... 15 6.3 Mechanical Resonances . ..................... 17 6.4 Seismometer Matching...this prism is ascertained, using autocollimating theodolites, either by directly "swinging" Polaris into the laboratory from outside through optical

  6. Precision siting of a particle accelerator; Locacao de precisao de um acelerador de particulas

    Energy Technology Data Exchange (ETDEWEB)

    Cintra, Jorge Pimentel

    1996-07-01

    Precise location is a specific survey job that involves a high skilled work to avoid unrecoverable results at the project installation. As a function of the different process stages, different specifications can be applied, invoking different instruments: theodolite, measurement tape, distanciometer, invar wire. This paper, based on experience obtained at the installation of particle accelerator equipment, deals with general principles of precise location: tolerance definitions, increasing accuracy techniques, schedule of locations, sensitivity analysis, quality control methods. (author)

  7. Precision siting of a particle accelerator

    International Nuclear Information System (INIS)

    Cintra, Jorge Pimentel

    1996-01-01

    Precise location is a specific survey job that involves a high skilled work to avoid unrecoverable results at the project installation. As a function of the different process stages, different specifications can be applied, invoking different instruments: theodolite, measurement tape, distanciometer, invar wire. This paper, based on experience obtained at the installation of particle accelerator equipment, deals with general principles of precise location: tolerance definitions, increasing accuracy techniques, schedule of locations, sensitivity analysis, quality control methods. (author)

  8. Systems of imaging digital systems in case of glaucoma

    International Nuclear Information System (INIS)

    Fernandez Argones, Liamet; Piloto Diaz, Ibrain; Coba Penna, Maria Josefa; Perez Tamayo, Bertila; Dominguez Randulfe, Marerneda; Trujillo Fonseca, Katia

    2009-01-01

    Now a day we can't consider the strict follow up in Glaucoma without the use of the digital analysis of image system of the optic nerve head and the retinal nerve fiber layer. This is a review about some contributions of Scanning Laser Polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, CA), Confocal Scanning Laser (Heidelberg Retina Tomograph HRT, Heidelberg Engineering Inc.) and Optical Coherence Tomography (Stratus OCT, Carl Zeiss Meditec, Alemania) in the diagnosis and follow up of Glaucoma. It's considered that objective measurement giving by them must be incorporate in the rigorous analysis of each glaucomatous patient

  9. Use of optical microscopes in research work in the field of work safety in mines

    Energy Technology Data Exchange (ETDEWEB)

    Piskorska-Kalisz, Z

    1979-05-01

    Notes that coal dust in mine air is measured by means of optical microscopes. The microscope is part of a dust counter called a konimeter. With the help of optical microscopes dust particles in a sample are counted. The Cawood-Patterson network is inserted in the eyepiece of a microscope. At present konimeters produced by Zeiss Works are used in Poland. In predicting rock burst hazard microscopes (light reflecting system) are used, e.g. Zeiss microscope Ng. With its help microcracks in coal samples are counted. An optical stereoscopic microscope is used for calculating the range of flames during coal dust explosions.

  10. CTC-Endothelial Cell Interactions during Metastasis

    Science.gov (United States)

    2014-06-01

    equipped with a Zeiss AxioCam MRm camera . A syringe pump (KDS 230, IITC Life Science, Woodland Hills, CA) was used to control the shear stress of the...HUVECs in 2 ml growth medium at 180 x g for 5 min. Measure the cell concentration using a neubauer hemocytometer and prepare 107 HUVEC cells/100 µl...selectin (R&D Systems, Minneapolis, MN). Coated microtubes were mounted on an inverted microscope equipped with a Zeiss AxioCam MRm camera . A syringe pump

  11. Generation of human antibody fragments recognizing distinct epitopes of the nucleocapsid (N SARS-CoV protein using a phage display approach

    Directory of Open Access Journals (Sweden)

    Grasso Felicia

    2005-09-01

    Full Text Available Abstract Background Severe acute respiratory syndrome (SARS-CoV is a newly emerging virus that causes SARS with high mortality rate in infected people. Successful control of the global SARS epidemic will require rapid and sensitive diagnostic tests to monitor its spread, as well as, the development of vaccines and new antiviral compounds including neutralizing antibodies that effectively prevent or treat this disease. Methods The human synthetic single-chain fragment variable (scFv ETH-2 phage antibody library was used for the isolation of scFvs against the nucleocapsid (N protein of SARS-CoV using a bio panning-based strategy. The selected scFvs were characterized under genetics-molecular aspects and for SARS-CoV N protein detection in ELISA, western blotting and immunocytochemistry. Results Human scFv antibodies to N protein of SARS-CoV can be easily isolated by selecting the ETH-2 phage library on immunotubes coated with antigen. These in vitro selected human scFvs specifically recognize in ELISA and western blotting studies distinct epitopes in N protein domains and detect in immunohistochemistry investigations SARS-CoV particles in infected Vero cells. Conclusion The human scFv antibodies isolated and described in this study represent useful reagents for rapid detection of N SARS-CoV protein and SARS virus particles in infected target cells.

  12. Association between physical and geochemical characteristics of ...

    African Journals Online (AJOL)

    Algae were identified with a Carl Zeiss inverted light microscope (magnification of 400 or 1 000). Sub- samples were taken until no new species .... An interesting picture that emerges from Table 2 is that certain algae are confined to specific ...

  13. The response of microalgal biomass and community composition to ...

    African Journals Online (AJOL)

    2011-06-06

    Jun 6, 2011 ... Estuary (33º 43' S; 25º 51' E), and is permanently open to the sea (Fig. 1). .... visualised using the Imaplan V 2.06 image analysis programme. (IMATEC ... using the Zeiss IM 35 inverted microscope at 630x magnifica- tion.

  14. Linear reciprocating wear behaviour of plasma-sprayed Al2O3 ...

    Indian Academy of Sciences (India)

    Balmukund Dhakar

    2017-08-31

    Aug 31, 2017 ... However, few reports are available on the compound effects of the variations in ... polished samples is studied by using field emission scan- ning electron microscope (FESEM, Zeiss Supra-55). The phases present in the ... calculated by measured track depth and width by Altisurf. 500 optical profiler (figure ...

  15. Thermal behaviour of strontium tartrate single crystals grown in gel

    Indian Academy of Sciences (India)

    Unknown

    Keywords. Strontium tartrate; dopant; effect of magnetic field; thermal behaviour. 1. Introduction ... tals of such type of compounds cannot be grown by either slow evaporation or ... is observed under a stereo binocular microscope (Carl. Zeiss) and ... a depth of 1⋅8 cm due to the diffusion of the top solution. After about a week ...

  16. A new rhodamine based 'turn-on' ion selective chemosensor in ...

    Indian Academy of Sciences (India)

    ABHISHEK MAJI

    2017-08-03

    Aug 3, 2017 ... working under a physiological condition with a fast response is highly .... fluorescence microscope (Carl Zeiss, Germany) using an oil immersion lens at 63X ... mg/mL PBS) was added to each well of a 96-well culture plate and ...

  17. Macular volume and central foveal thickness measurements in ...

    African Journals Online (AJOL)

    Objective: To determine macular volume and central foveal thickness measurements in normal eyes of healthy. Nigerian adults using Stratus optical coherence tomography. Subjects and Methods: Consenting 100 adults Nigerians with normal eyes were recruited and examined using Carl. Zeiss Stratus Optical Coherence ...

  18. Porcine circovirus type 2 ORF4 protein binds heavy chain ferritin

    Indian Academy of Sciences (India)

    2015-08-13

    Aug 13, 2015 ... protein is a newly identified viral protein of PCV2 and is involved in ... The porcine alveolar macrophages (PAMs) of a healthy, 2- .... firmation by restriction analysis and DNA sequencing, the ... croscope (Model LSM510 META, Zeiss). ..... circovirus-like viruses from pigs with a wasting disease in the.

  19. Journal of Astrophysics and Astronomy | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... Keywords. Telescopes; method: observational; stars: oscillation. Abstract. The Maidanak One-meter Telescope (MOT) is a Ritchey-Chretien telescope by Carl Zeiss, located atop Maidanak in Uzbekistan, where site parameters indicate excellent atmospheric seeing conditions. An effort to computerize the ...

  20. Nanofluidic Pre-Concentration Devices for Enhancing the Detection Sensitivity and Selectivity of Biomarkers for Human Performance Monitoring

    Science.gov (United States)

    2012-12-01

    approximately 1.5 V/cm field strength. The preconcentration of fluorescently labeled strep- tavidin protein samples (52.8 kDa, Molecular Probes, Engene , OR, USA...Molecular Probes, Engene , OR) or ~50 nm silica nanoparticles (Corpuscular Inc., Cold Spring, NY) using an inverted microscope (Zeiss Observer A1

  1. Determination of Serum Lithium by Flame Emission Spectroscopy

    Directory of Open Access Journals (Sweden)

    R. Nafissy

    1976-07-01

    Full Text Available Lithum can be de termined both by atomic absorption spectroscopy andflame emission spectroscopy. We have used the later method with a Zeiss Model pMQlI spectro photometer fitt ed with ante-chamber atomizer and a potensiome rric line recorder. Accurate ana lysis for the clement was acco mplished due to a sophisracared measuring instrument.

  2. Dual Beam System (SEM/FIB) Equipment for the Kleberg Advanced Microscopy Center

    Science.gov (United States)

    2015-06-05

    PRODUCT, INCLUDING SPECIFICALLY, BUT WITHOUT LIMITATION, LIABILITY FOR NEGLIGENCE OR STRICT LIABILITY IN TORT . NOTWITHSTANDING ANY OTHER PROVISION OF THIS...CONTRACT OR TORT ) TO BUYER OR ANY OTHER PERSON FOR ANY PUNITIVE, SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WITH RESPECT TO ZEISS’S OBLIGATIONS HEREUNDER

  3. Hydrothermal Synthesis of NiFe2O4 nano-particles: Structural ...

    Indian Academy of Sciences (India)

    10

    Cole plots are drawn to study electrical conduction mechanism and the kind of ... Zeiss), Transmission Electron Microscope (TEM: Model Tecnai G20, FEI, USA), JASCO ...... Z' Vs. Z" plot (Nyquist plot) of NiFe2O4 at room temperature (RT).

  4. Newly designed, simple relief phase contrast for microscopy of microorganisms

    Czech Academy of Sciences Publication Activity Database

    Žižka, Zdeněk

    2010-01-01

    Roč. 55, č. 6 (2010), s. 662-665 ISSN 0015-5632 R&D Projects: GA MŠk LC06066 Institutional research plan: CEZ:AV0Z50200510 Keywords : optical microscopy * Zeiss NG 10/1 * microphotography Subject RIV: EE - Microbiology, Virology Impact factor: 0.977, year: 2010

  5. The Replication Stress Response in Pancreatic Cancer

    Science.gov (United States)

    2014-12-01

    both causes cell death. We hypothesize that novel RSR genes maintain genome integrity and that deregulation of RSR genes and their cancer barrier...Microscopy, Jena, Germany ) microscope with Axiovision Rei 4.8 software (Zeiss, Jena. Germany ) using the x 63 oil objective. Foci quantitation was

  6. Heating ability and biocompatibility study of silica-coated magnetic ...

    Indian Academy of Sciences (India)

    systems, MNPs are normally coated with a thermosensitive polymer ... and dispersed in water alkalized by adding some drops of ammonia ... The morphology and particle size distribution of nanoparti- cles were examined using a Zeiss-EM10C transmission elec- tron microscope (TEM) operated at an acceleration voltage.

  7. Compilation of 1993 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G-I

    Science.gov (United States)

    1994-04-01

    10 2 2 Regulus satrapa Ruby-crowned Kinglet 2 10 2 2 Regulus calendula Blue-gray Gnatcatcher 3 10 1 3 Polioptila caerulea Eastern Bluebird 4 12 5 2...on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX Neofluar phase objective with numerical aperture of 1.30

  8. Compilation of 1991 Annual Reports of the Navy ELF Communications Systems Ecological Monitoring Program

    Science.gov (United States)

    1992-08-01

    crowned Kinglet 46 36 48 31 49 40 7 12 15 11 Reaulus satraoaa I Ruby-crowned Kinglet 19 9 4 2 1 0 0 0 1 0 Regulus calendula I Eastern Bluebird 0 0 3 2 0 0...determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX Neofluar phase

  9. Evaluation of actual vs expected photodynamic therapy spot size.

    Science.gov (United States)

    Ranchod, Tushar M; Brucker, Alexander J; Liu, Chengcheng; Cukras, Catherine A; Hopkins, Tim B; Ying, Gui-Shuang

    2009-05-01

    To determine the accuracy of the photodynamic therapy (PDT) laser spot size on the retina as generated by 2 Food and Drug Administration (FDA)-approved lasers. Prospective observational case series. Fundus photographs were taken of 1 eye of each of 10 subjects with the WinStation 4000 fundus photography system (OIS; Ophthalmic Imaging Systems, Sacramento, California, USA); disc size was calculated using OIS software. Slit-lamp photographs were taken of the PDT laser spot focused on the retina adjacent to the optic disc, using various spot sizes in combination with 3 different contact lenses and 2 different lasers. Spot size at the retina was determined by measuring the ratio of disc diameter to spot diameter in Adobe Photoshop (San Jose, California, USA) and applying this ratio to the OIS disc measurements. Spot size at the retina averaged 87% of expected spot size for the Coherent Opal laser (Coherent Inc, Santa Clara, California, USA) and 104% of expected spot size for the Zeiss Visulas laser (Carl Zeiss Meditec Inc, Dublin, California, USA)(P = .002). Multivariate analysis demonstrated that percentage of expected spot size decreased with larger spot diameter (P = .01 for Coherent laser; P = .02 for Zeiss laser). PDT spot size at the retina appears to be consistently smaller than expected for the Coherent laser while the spot size was consistently within 10% of expected size for the Zeiss laser. The deviation from expected size increased with larger spot size using the Coherent laser.

  10. Global analytic treatment of terrestrial photogrammetric networks

    CERN Document Server

    Mayoud, M

    1980-01-01

    In order to solve certain special CERN metrology problems, analytical terrestrial photogrammetry may have some advantages which are first discussed along with their drawbacks and limitations. In this application, it is necessary to carry out a rigorous and global adjustment of the observations and simultaneously process all the perspective ray bundles. The basic principles, the least squares solution and the stochastic analysis of the results are presented. However, for the CERN project, one wonders if the production of digital theodolites is going to reduce the advantages of the photogrammetric method. (12 refs).

  11. Re-Evaluation of Geomagnetic Field Observation Data at Syowa Station, Antarctica

    Directory of Open Access Journals (Sweden)

    K Takahashi

    2013-05-01

    Full Text Available The Japanese Antarctic Research Expedition has conducted geomagnetic observations at Syowa Station, Antarctica, since 1966. Geomagnetic variation data measured with a fluxgate magnetometer are not absolute but are relative to a baseline and show drift. To enhance the importance of the geomagnetic data at Syowa Station, therefore, it is necessary to correct the continuous variation data by using absolute baseline values acquired by a magnetic theodolite and proton magnetometer. However, the database of baseline values contains outliers. We detected outliers in the database and then converted the geomagnetic variation data to absolute values by using the reliable baseline values.

  12. Hidrología y variación topográfica de un riachuelo subantártico en la ensenada MacKellar, Isla Rey Jorge, Antártida

    OpenAIRE

    Tavares Correa, Carlos

    2015-01-01

    The purpose of this study is to present preliminary results of the hydrologic and topographic monitoring of a small stream at the King George Island, Antarctica. Two methods were used in order to measure stream discharge: an area-velocity method using a flow meter and a Parshall flume. Also a topographical survey was made using a total-station theodolite. Great stream discharge fluctuations were identified at the seven stream sections between January 21st and February 13th, 2000. Comparison b...

  13. Helical coil alignment in the advanced toroidal facility

    International Nuclear Information System (INIS)

    Taylor, D.J.; Cole, M.J.; Johnson, R.L.; Nelson, B.E.; Warwick, J.E.; Whitson, J.C.

    1985-01-01

    This paper presents a brief overview of the helical coil design concept, detailed descriptions of the method for installation and alignment, and discussions of segment installation and alignment equipment. Alignment is accomplished by optical methods using electronic theodolites connected to a microcomputer to form a coordinate measurement system. The coordinate measurement system is described in detail, along with target selection and fixturing for manipulation of the helical coil segments during installation. In addition, software is described including vendor-supplied software used in the coordinate measurement system and in-house-developed software used to calibrate segment and positioning fixture motion. 2 refs., 8 figs

  14. Recent development of micro-triangulation for magnet fiducialisation

    CERN Document Server

    Vlachakis, Vasileios; Mainaud Durand, Helene; CERN. Geneva. ATS Department

    2016-01-01

    The micro-triangulation method is proposed as an alternative for magnet fiducialisation. The main objective is to measure horizontal and vertical angles to fiducial points and stretched wires, utilising theodolites equipped with cameras. This study aims to develop various methods, algorithms and software tools to enable the data acquisition and processing. In this paper, we present the first test measurement as an attempt to demonstrate the feasibility of the method and to evaluate the accuracy. The preliminary results are very promising, with accuracy always better than 20 μm for the wire position, and of about40 μm/m for the wire orientation, compared with a coordinate measuring machine.

  15. CDF central detector installation. An efficient merge of digital photogrammetry and laser tracker metrology

    International Nuclear Information System (INIS)

    Greenwood, John A.; Wojcik, George J.

    2003-01-01

    Metrology for Run II at the Collider Detector at Fermilab (CDF) required a very complex geodetic survey. The Collision Hall network, surveyed with a Laser Tracker and digital level, provides a constraining network for the positioning of the Central Detector (CD). A part-based Laser Tracker network, which surrounded the 2,000-ton CD, was used as control for assembly. Subassembly surveys of the Detector's major components were measured as independent networks using Laser Tracker, V-STARS/S (Video-Simultaneous Triangulation And Resection System/Single camera) digital photogrammetry system, and BETS (Brunson Electronic Theodolite System) theodolite triangulation system. Each subassembly survey was transformed into and constrained by the part-based network. For roll-in, the CD part-based network was transformed into the Collision Hall network coordinate system. The CD was positioned in the Collision Hall using two Laser Trackers in 'stakeout mode.' This paper discusses the survey, adjustment, transformation, and precision of the various networks. (author)

  16. All-Fiber Airborne Coherent Doppler Lidar to Measure Wind Profiles

    Directory of Open Access Journals (Sweden)

    Liu Jiqiao

    2016-01-01

    Full Text Available An all-fiber airborne pulsed coherent Doppler lidar (CDL prototype at 1.54μm is developed to measure wind profiles in the lower troposphere layer. The all-fiber single frequency pulsed laser is operated with pulse energy of 300μJ, pulse width of 400ns and pulse repetition rate of 10kHz. To the best of our knowledge, it is the highest pulse energy of all-fiber eye-safe single frequency laser that is used in airborne coherent wind lidar. The telescope optical diameter of monostatic lidar is 100 mm. Velocity-Azimuth-Display (VAD scanning is implemented with 20 degrees elevation angle in 8 different azimuths. Real-time signal processing board is developed to acquire and process the heterodyne mixing signal with 10000 pulses spectra accumulated every second. Wind profiles are obtained every 20 seconds. Several experiments are implemented to evaluate the performance of the lidar. We have carried out airborne wind lidar experiments successfully, and the wind profiles are compared with aerological theodolite and ground based wind lidar. Wind speed standard error of less than 0.4m/s is shown between airborne wind lidar and balloon aerological theodolite.

  17. Optimization and validation of a method for the determination of the refractive index of milk serum based on the reaction between milk and copper(II) sulfate to detect milk dilutions.

    Science.gov (United States)

    Rezende, Patrícia Sueli; Carmo, Geraldo Paulo do; Esteves, Eduardo Gonçalves

    2015-06-01

    We report the use of a method to determine the refractive index of copper(II) serum (RICS) in milk as a tool to detect the fraudulent addition of water. This practice is highly profitable, unlawful, and difficult to deter. The method was optimized and validated and is simple, fast and robust. The optimized method yielded statistically equivalent results compared to the reference method with an accuracy of 0.4% and quadrupled analytical throughput. Trueness, precision (repeatability and intermediate precision) and ruggedness are determined to be satisfactory at a 95.45% confidence level. The expanded uncertainty of the measurement was ±0.38°Zeiss at the 95.45% confidence level (k=3.30), corresponding to 1.03% of the minimum measurement expected in adequate samples (>37.00°Zeiss). Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Small Incision Lenticule Extraction (SMILE) vs. Femtosecond Laser in Situ Keratomileusis (FS-LASIK) for treatment of myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Justesen, Birgitte

    Purpose: - 67 ord LASIK has been the dominating corneal refractive procedure for almost two decades, but the new flap-free SMILE procedure has shown promising results. The aim of this study was to evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA...... and CDVA), and safety at 1 day, 1 week and 3 months after SMILE and FS-LASIK for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark Methods: - 157 ord Retrospective study of results after SMILE and FS-LASIK for all degrees...... having undergone re-treatment. The SMILE treatments and FS-LASIK flaps were performed with a VisuMax® femtosecond laser (Carl Zeiss-Meditec, Jena, Germany). The FS-LASIK photoablation was performed with a MEL-80 flying-spot excimer laser with eye-tracker (Carl Zeiss-Meditec, Jena, Germany). In SMILE...

  19. Installation of a technological center for highly efficient optical gratings at Helmholtz-Zentrum Berlin (HZB)

    International Nuclear Information System (INIS)

    Loechel, B; Erko, A; Lemke, St; Senf, F; Nelles, B; Schmidt, M

    2013-01-01

    In 2009 Carl Zeiss stopped the manufacture of precision gratings. All users of their gratings were very concerned about this decision, since they all need precision gratings for their experiments. One of the institutes of the HZB, the Institute for Nanometer Optics and Technology (INT), has extensive experience in micro fabrication (technology group). In spring 2010, HZB decided to take over the old C. Zeiss grating fabrication and build up its own technology center for grating fabrication. In March 2010, the INT applied to the Senate of Berlin for funding for our project from the European Regional Development Fund (ERDF). In October 2010, HZB received an approval of its application from the Senate of Berlin (contract No 20072013 2/43). Using this governmental support, HZB will install all necessary equipment and processes to fulfill these demands until end of 2013.

  20. Whither a "National Planetarium"?

    Science.gov (United States)

    DeVorkin, David

    2018-01-01

    In Spring 1927 Zeiss contacted the Smithsonian Institution about its new wonderful planetarium projector, sending along brochures and testimonials from astronomers. By the end of the year after much back and forth, Zeiss even found backers to underwrite the planetarium for the Smithsonian, feeling that the first planetarium should be built in Washington. Over the following decades, the push for a “national planetarium” revived several times, as a possible option for Jefferson’s Memorial or as a commercial enterprise to revitalize the southwest quadrant of the city. It was even the topic for a student essay contest. Nothing caught on, though planetariums soon proved to be wildly popular in the cities that nurtured them. Here I’ll outline the efforts for Washington, D.C. and ask what the campaigns reveal about the perception of astronomy on the National Mall.

  1. Pseudo-gonio synechia: An artifact on two-mirror gonioscopy

    Directory of Open Access Journals (Sweden)

    Garudadri Chandra

    2010-01-01

    Full Text Available Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-goniosynechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  2. Pseudo-gonio synechia: an artifact on two-mirror gonioscopy.

    Science.gov (United States)

    Garudadri, Chandra Sekhar

    2010-01-01

    Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-gonio synechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  3. Pseudo-gonio synechia: An artifact on two-mirror gonioscopy

    OpenAIRE

    Garudadri, Chandra Sekhar

    2010-01-01

    Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-goniosynechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.

  4. Investment Casting vs Replicast CS Considered in Terms of the Ceramic Mould Making and Dimensional Accuracy of Castings

    Directory of Open Access Journals (Sweden)

    Karwiński A.

    2014-03-01

    Full Text Available The article presents an analysis of the applicability of the Replicast CS process as an alternative to the investment casting process, considered in terms of the dimensional accuracy of castings. Ceramic shell moulds were based on the Ekosil binder and a wide range of ceramic materials, such as crystalline quartz, fused silica, aluminosilicates and zirconium silicate. The linear dimensions were measured with a Zeiss UMC 550 machine that allowed reducing to minimum the measurement uncertainty

  5. Studies on The Mechanism of The Microfilarial Periodicity(FN-4) : Studies on the essential feature of the autofluorescent substance(s) in the nocturnalmicronlariae (B)

    OpenAIRE

    真喜志, 金造; Makaishi, Kinzo; 琉球大学医学部第一内科学教室

    1981-01-01

    1. The night specimens of Mf. immitis emitted significantly more photons in 5seconds,excited by near 400nm, than those emitted from the daytime specimens. 2. Laser-Raman analysis detected in Mf. immitis the presence of Vitamin A, showing prominent Raman line near 1600cm-1, just samely with that of authentic V. A palmitate. 3. The similarity to rhodopsin and its intermediates was pursued. Microscopic fluorescence spectra, taken using UMSP-1 Zeiss, equipped with a Farrand-fluorescenee recorder,...

  6. Ultrastructural features of Mimulus aurantiacus (Scrophulariaceae) pollen tubes in vivo

    OpenAIRE

    Ekici,Nuran; Dane,Feruzan; Olgun,Göksel

    2009-01-01

    The aim of this study is to give information on ultrastructure of in vivo pollen tubes of Mimulus aurantiacus which were collected from the Botanical Garden of the University of California at Berkeley. Materials were prepared according to electron microscopy methods and examined under Zeiss electron microscope. Four zones were examined in the pollen tubes of Mimulus aurantiacus. APICAL ZONE: Mitochondria, smooth endoplasmic reticulum, rough endoplasmic reticulum, dictyosomes and secretory ves...

  7. Topological laser speckle analyzer of differentiation and proliferation activity during morphogenesis in cell cultures

    OpenAIRE

    Notchenko A.V.; Gradov O.V.

    2011-01-01

    An automated system for morpho-topological determination of cell division phases and structur al differentiation of tissues during morphogenesis was implemented on the basis of topological properties of cell cultures, considered within the framework of set and manifold theories. A simple robotic hardware and software system based on Zeiss microscope with a modified stage and a Velleman manipulator KSR-1 allow to control the laser module position, carrying out the angular irradiation of s...

  8. Direct Functionalization of Kevlar (registered trademark) with Copolymers Containing Sulfonyl Nitrene

    Science.gov (United States)

    2016-01-01

    alumina plug. Methacrylic acid was purified by vacuum distillation. Penta- fluorophenol acrylate was synthesized according to a pre- viously published...megapixel digital camera on a Zeiss AX10 Observer inverted microscope with an X-cite Series 120 fluorescent light source and Chroma Technol- ogy filter...Polypentafluorophenolacrylate-co-styrene sulfonyl azide (pPFPA-co-SSAz) (7) 1.0 g (4.2 mmol) of pentafluorophenol acrylate , 46 mg (0.22 mmol) styrene

  9. Diabetes induces changes in neuroretina before retinal vessels: a spectral-domain optical coherence tomography study

    OpenAIRE

    Rodrigues, Eduardo B?chele; Urias, M?ller Gon?alves; Penha, Fernando Marcondes; Badar?, Emmerson; Novais, Eduardo; Meirelles, Rodrigo; Farah, Michel Eid

    2015-01-01

    Purpose To investigate retinal changes prior to vascular signs in patients with type 2 diabetes without diabetic retinopathy or with mild non proliferative diabetic retinopathy. Methods A cross-sectional study was performed in three groups: patients without diabetes, patients with type 2 diabetes without diabetic retinopathy, and patients with diabetes with mild diabetic retinopathy. Analysis of retinal layers was performed objectively with the Cirrus Review Software 6.0 (Carl Zeiss Meditec, ...

  10. Effet de l'amendement au carbonate de calcium (mikhart) de ...

    African Journals Online (AJOL)

    SARAH

    31 janv. 2017 ... control substratum, SCa10 (S0 + 10 % powder of calcium carbonate), SCa20 (S0 + 20 % powder of calcium carbonate), SCa30 (S0 ..... puis montés sur un microscope électronique FEG Supra. 40 VP Zeiss à balayage et pression variable. Dès lors, ..... substrats amendés d'un apport en quantité et en qualité.

  11. Effect of Bleaching on Color Change and Surface Topography of Composite Restorations

    OpenAIRE

    Pruthi, Gunjan; Jain, Veena; Kandpal, H. C.; Mathur, Vijay Prakash; Shah, Naseem

    2010-01-01

    This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE), Esthet X (Dentsply India), and Admira (Voco, Germany). Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS). 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Den...

  12. Fluorimetric routine determination of uranium in urine samples

    International Nuclear Information System (INIS)

    Widua, L.; Schieferdecker, H.; Hezel, U.

    With a modified RA 2 reflectance accessory for the Zeiss PMQII/PMQ3 spectrophotometer, uranium in urine was detected with higher sensitivity. A quick method is now available with a detection limit of <2 μg U/1 urine for the determination of possible uranium incorporations, whose sensitivity meets the requirements of radiation protection. Compared with other extraction methods, the instrument outlay and the required working time are small. The total error of the method is below 5 percent

  13. Gratings for synchrotron and FEL beamlines: a project for the manufacture of ultra-precise gratings at Helmholtz Zentrum Berlin.

    Science.gov (United States)

    Siewert, F; Löchel, B; Buchheim, J; Eggenstein, F; Firsov, A; Gwalt, G; Kutz, O; Lemke, St; Nelles, B; Rudolph, I; Schäfers, F; Seliger, T; Senf, F; Sokolov, A; Waberski, Ch; Wolf, J; Zeschke, T; Zizak, I; Follath, R; Arnold, T; Frost, F; Pietag, F; Erko, A

    2018-01-01

    Blazed gratings are of dedicated interest for the monochromatization of synchrotron radiation when a high photon flux is required, such as, for example, in resonant inelastic X-ray scattering experiments or when the use of laminar gratings is excluded due to too high flux densities and expected damage, for example at free-electron laser beamlines. Their availability became a bottleneck since the decommissioning of the grating manufacture facility at Carl Zeiss in Oberkochen. To resolve this situation a new technological laboratory was established at the Helmholtz Zentrum Berlin, including instrumentation from Carl Zeiss. Besides the upgraded ZEISS equipment, an advanced grating production line has been developed, including a new ultra-precise ruling machine, ion etching technology as well as laser interference lithography. While the old ZEISS ruling machine GTM-6 allows ruling for a grating length up to 170 mm, the new GTM-24 will have the capacity for 600 mm (24 inch) gratings with groove densities between 50 lines mm -1 and 1200 lines mm -1 . A new ion etching machine with a scanning radiofrequency excited ion beam (HF) source allows gratings to be etched into substrates of up to 500 mm length. For a final at-wavelength characterization, a new reflectometer at a new Optics beamline at the BESSY-II storage ring is under operation. This paper reports on the status of the grating fabrication, the measured quality of fabricated items by ex situ and in situ metrology, and future development goals.

  14. EXPERIMENTAL MEASUREMENTS OF TAILING UNDERWATER SEDIMENTS AND LIQUID INDUSTRIAL WASTES IN STORAGE TANK ON THE BASIS OF ECHOLOCATION AND GPS-SYSTEMS AT JSC “BELARUSKALI”

    Directory of Open Access Journals (Sweden)

    V. I. Mikhailov

    2016-01-01

    Full Text Available The paper presents a new approach to calculate volume of tailing underwater sediments and liquid industrial wastes on the basis of innovative technologies. Two theodolites which are set at various points and a boat with a load for measuring water depth have been traditionally used for topographic survey of slime storage bottom. Horizontal directions have been simultaneously measured on the boat marker while using theodolites. Water depth has been determined while using  a 2-kg circular load which was descended into brine solution with the help of rope. In addition to rather large time and labour costs such technology has required synchronization in actions on three participants involved in the work: operators of two theodolites and boat team in every depth measuring point. Methodology has been proposed for more efficient solution of the problem. It presupposes the use of echolocation together with space localization systems (GPS-systems which can be set on a boat with the purpose to measure depth of a storage tank bed. An echolocation transducer has been installed under the boat bottom at the depth of 10 cm from the brine solution level in the slime storage.  An aerial of GPS-receiver has been fixed over the echo-sounder transducer. Horizontal positioning of bottom depth measuring points have been carried out in the local coordinate system. Formation of digital model for slime storage bottom has been executed after data input of the coordinate positioning that corresponded to corrected depths in the software package LISCAD Plus SEE. The formation has been made on the basis of a strict triangulation method.  Creation of the digital model makes it rather easy to calculate a volume between a storage bottom and a selected level (height of filling material. In this context it is possible to determine a volume and an area not only above but also lower of the datum surface. For this purpose it is recommended to use digital models which are developed

  15. Application for surveying technology for the alignment of large optical systems

    International Nuclear Information System (INIS)

    Bauke, W.

    1984-01-01

    Precise alignment of optical elements in large optical systems is difficult if many elements are positioned such that direct alignment or boresighting becomes impossible. A practical approach is to identify discrete optical path segments and align these using standard surveying or optical-tooling instrumentation. One simply has to develop an alignment theory in which the alignment optical path duplicates or closely approximates the optical path of the operational device. The surveying instruments can then be used to simulate the optical input beams to the system segments to be aligned. Auxiliary targets and reflectors may be added, and the alignment procedure may be augmented by standard optical test instrumentation and techniques. Examples are given using theodolites, transits, and levels with autocollimating capability and micrometer adaptors to perform boresighting and autocollimation techniques on segments of the optical train of the Antares Laser Fusion System at Los Alamos National Laboratory

  16. Precision and accuracy of the static GNSS system for surveying networks used in Civil Engineering

    Directory of Open Access Journals (Sweden)

    Nixon Alexander Correa Muñoz

    2018-01-01

    Full Text Available A field check was implemented for calibrating surveying equipment. It was geo-referenced with a Total Station Theodolite and by implementing procedures concerning repeatability and reproducibility. We carried out GNSS (Global Navigation Satellite System static positioning with double frequency equipment, sensitizing occupation times, day times, uncorrected coordinates subjected to a differential correction procedure and type of coordinates obtained. This facilitated an evaluation of precision and accuracy for the GNSS positioning with the static method, which gave a global RMSE (root mean square error of 1 cm for conditions with no multipath effect and 4 cm for field calibration points close to buildings. Additionally, optimal results for occupation times of 30 minutes were found, and the need to use planar Cartesian coordinates to ensure compatibility with the surveys using electronic measurement of distances, which allows the use of the static GNSS positioning for geo-referencing precise surveying networks, and can be used in different applications in Civil Engineering.

  17. Blast forecasting guide for the Site 300 Meteorology Center

    International Nuclear Information System (INIS)

    Odell, B.N.; Pfeifer, H.E.; Arganbright, V.E.

    1978-01-01

    These step-by-step procedures enable an occasional operator to run the Site 300 Meteorological Center. The primary function of the Center is to determine the maximum weight of high explosives that can be fired at Site 300 under any given meteorological conditions. A secondary function is to supply weather data for other programs such as ARAC (Atmospheric Release Advisory Capability). Included in the primary function are radar and theodolite operations for balloon tracking; calculation of temperatures for various altitudes using Oakland weather obtained from a teletype; computer terminal operation to obtain wind directions, wind velocities, temperatures, and pressure at various altitudes; and methods to determine high-explosive weight limits for simple inversions and focus conditions using pressure-versus-altitude information obtained from the computer. General information is included such as names, telephone numbers, and addresses of maintenance personnel, additional sources of weather information, chart suppliers, balloons, spare parts, etc

  18. Optics Alignment of a Balloon-Borne Far-Infrared Interferometer BETTII

    Science.gov (United States)

    Dhabal, Arnab; Rinehart, Stephen A.; Rizzo, Maxime J.; Mundy, Lee; Sampler, Henry; Juanola Parramon, Roser; Veach, Todd; Fixsen, Dale; Vila Hernandez De Lorenzo, Jor; Silverberg, Robert F.

    2017-01-01

    The Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) is an 8-m baseline far-infrared (FIR: 30 90 micrometer) interferometer providing spatially resolved spectroscopy. The initial scientific focus of BETTII is on clustered star formation, but this capability likely has a much broader scientific application.One critical step in developing an interferometer, such as BETTII, is the optical alignment of the system. We discuss how we determine alignment sensitivities of different optical elements on the interferogram outputs. Accordingly, an alignment plan is executed that makes use of a laser tracker and theodolites for precise optical metrology of both the large external optics and the small optics inside the cryostat. We test our alignment on the ground by pointing BETTII to bright near-infrared sources and obtaining their images in the tracking detectors.

  19. Surveying and optical tooling technologies combined to align a skewed beamline at the LAMPF accelerator

    International Nuclear Information System (INIS)

    Bauke, W.; Clark, D.A.; Trujillo, P.B.

    1985-01-01

    Optical Tooling evolved from traditional surveying, and both technologies are sometimes used interchangeably in large industrial installations, since the instruments and their specialized adapters and supports complement each other well. A unique marriage of both technologies was accomplished in a novel application at LAMPF, the Los Alamos Meson Physics Facility. LAMPF consists of a linear accelerator with multiple target systems, one of which had to be altered to accommodate a new beamline for a neutrino experiment. The new line was to be installed into a crowded beam tunnel and had to be skewed and tilted in compound angles to avoid existing equipment. In this paper we describe how Optical Tooling was used in conjunction with simple alignment and reference fixtures to set fiducials on the magnets and other mechanical components of the beamline, and how theodolites and sight levels were then adapted to align these components along the calculated skew planes. Design tolerances are compared with measured alignment results

  20. Methodology For Determination Of Space Control For 3D Reconstruction In Statscan Digital X-Ray Radiology Using Static Frame Model

    Directory of Open Access Journals (Sweden)

    Jacinta S. Kimuyu

    2015-08-01

    Full Text Available The methodology was designed to employ two positioning techniques in order to determine the three-dimensional control space of target points on static metal frame model to be used as space control data in 3D reconstructions in Statscan digital X-Ray imaging. These techniques were digital close-range photogrammetry and precise theodolite positioning method. The space coordinates for the target points were determined 3D using both techniques. Point positioning accuracy 0.5mm in root mean square error of X Y and Z space coordinates was achieved. The outcome of the comparison of the results obtained from both methods were of satisfactory accuracy hence further use of the control space data in Stastcan imaging and 3D reconstruction.

  1. The distance from CERN to LNGS

    CERN Document Server

    Jones, M; Crespi, M; Colosimo, G; Mazzoni, A; Durand, S

    2012-01-01

    The calculation of the distance from CERN to Gran Sasso involves the combination of three independent sets of measurements: the calculation of the distance between pillars included in the geodetic reference network at CERN and the Lab Nationale Gran Sasso (LNGS); and the transfer on each site of coordinates, from the geodetic surface network, underground into the tunnel or experiment hall installations. The transfer of coordinates, from the surface, underground at the two sites was not done as part of the CNGS Project. Initial survey concerns for the project were directed towards the orientation of the beamline from CERN to LNGS to within ~100 m. Gyro-theodolite measurements underground were planned at CERN so a transfer would effectively only translate the target point. Given the precision estimated for previous transfers, it was decided not to undertake expensive and time-consuming measurements campaigns for a negligible gain in accuracy. Therefore only GPS measurements at the two sites were carried out. Th...

  2. Blast forecasting guide for the Site 300 Meteorology Center

    Energy Technology Data Exchange (ETDEWEB)

    Odell, B.N.; Pfeifer, H.E.; Arganbright, V.E.

    1978-06-01

    These step-by-step procedures enable an occasional operator to run the Site 300 Meteorological Center. The primary function of the Center is to determine the maximum weight of high explosives that can be fired at Site 300 under any given meteorological conditions. A secondary function is to supply weather data for other programs such as ARAC (Atmospheric Release Advisory Capability). Included in the primary function are radar and theodolite operations for balloon tracking; calculation of temperatures for various altitudes using Oakland weather obtained from a teletype; computer terminal operation to obtain wind directions, wind velocities, temperatures, and pressure at various altitudes; and methods to determine high-explosive weight limits for simple inversions and focus conditions using pressure-versus-altitude information obtained from the computer. General information is included such as names, telephone numbers, and addresses of maintenance personnel, additional sources of weather information, chart suppliers, balloons, spare parts, etc.

  3. LAMPF transition-region mechanical fabrication

    International Nuclear Information System (INIS)

    Bush, E.D. Jr.; Gallegos, J.D.F.; Harrison, R.; Hart, V.E.; Hunter, W.T.; Rislove, S.E.; Sims, J.R.; Van Dyke, W.J.

    1984-07-01

    The primary purpose of the new Transition Region (TR-II) is to optimize the phase matching of the H + and H - beams during simultaneous transport. TR-II incorporates several design improvements that include larger aperture, a straight beam track, greater beam-path length adjustments, and utility lines integrated with the support system. The close pack density of magnets and beam-line hardware required innovative solutions to magnet design and mounting, vacuum manifolding, and utility routing. Critical magnet placement was accomplished using a new three-dimensional alignment system that does real-time vector calculations on a computer with input from two digital theodolites. All assembly and a large fraction of the mechanical fabrication were done by LAMPF personnel. The TR-II has been operational since September 1983 and routinely transports production beams up to 900-μA current with no major problems

  4. A digital video tracking system

    Science.gov (United States)

    Giles, M. K.

    1980-01-01

    The Real-Time Videotheodolite (RTV) was developed in connection with the requirement to replace film as a recording medium to obtain the real-time location of an object in the field-of-view (FOV) of a long focal length theodolite. Design philosophy called for a system capable of discriminatory judgment in identifying the object to be tracked with 60 independent observations per second, capable of locating the center of mass of the object projection on the image plane within about 2% of the FOV in rapidly changing background/foreground situations, and able to generate a predicted observation angle for the next observation. A description is given of a number of subsystems of the RTV, taking into account the processor configuration, the video processor, the projection processor, the tracker processor, the control processor, and the optics interface and imaging subsystem.

  5. Passive acoustic monitoring of toothed whales with implications for mitigation, management and biology

    DEFF Research Database (Denmark)

    Kyhn, Line Anker

    these differences to successfully differentiate the species in Monte Carlo simulations, which means that it may also be possible to separate sympatric NBHF species with acoustic monitoring. Secondly, I was interested in examining the species differences in an evolutionary light to see if there were differences...... that describes the probability of detecting an acoustic cue at a given distance from the datalogger? In chapter II I describe one such possibility where we tracked harbour porpoises visually around dataloggers by means of a theodolite and following compared the visual and acoustic detections in a mark...... is in accordance with new molecular phylogenies. In chapter I use the information I have gathered on spectral source properties as well as on source levels and directionality and use this information to challenge the theories for the evolution of the NBHF click type. I conclude that the NBHF signals likely evolved...

  6. CIRCLE Enhancement After Myopic SMILE.

    Science.gov (United States)

    Siedlecki, Jakob; Luft, Nikolaus; Mayer, Wolfgang J; Siedlecki, Martin; Kook, Daniel; Meyer, Bertram; Bechmann, Martin; Wiltfang, Rainer; Priglinger, Siegfried G; Dirisamer, Martin

    2018-05-01

    To report the outcomes of enhancement after small incision lenticule extraction (SMILE) using the VisuMax CIRCLE option (Carl Zeiss Meditec AG, Jena, Germany), which converts the SMILE cap into a femtosecond LASIK flap for secondary excimer laser application. Of 2,065 SMILE procedures, 22 eyes (1.1%) re-treated with CIRCLE with a follow-up of 3 months were included in the analysis. SMILE was performed in the usual manner. For re-treatment, the CIRCLE procedure was performed with pattern D flap creation on the VisuMax system and subsequent excimer laser ablation with a Zeiss MEL 90 laser (Carl Zeiss Meditec) with plano target in all cases. Spherical equivalent was -5.56 ± 2.22 diopters (D) before SMILE and -0.51 ± 1.08 D before CIRCLE. CIRCLE enhancement was performed after a mean of 10.0 ± 7.9 months, allowed for safe flap lifting in all eyes, and resulted in a final manifest refraction spherical equivalent of 0.18 ± 0.31 D at 3 months (P line of UDVA. Corrected distance visual acuity (CDVA) remained unchanged at all time points (before vs after CIRCLE, P = .40). Two eyes (9.1 %) lost one line of CDVA; no eye lost two or more lines. The safety and efficacy indices were 1.03 and 0.97 at 3 months. The CIRCLE procedure represents an effective re-treatment option after SMILE. Compared to surface ablation re-treatment after SMILE, CIRCLE seems to offer advantages in respect to speed of visual recovery, safety, and predictability, but at the price of flap creation. [J Refract Surg. 2018;34(5):304-309.]. Copyright 2018, SLACK Incorporated.

  7. Bursting Smoke as an Infrared Countermeasure

    OpenAIRE

    Amarjit Singh; P. J. Kamale; S. A. Joshi; L. K. Bankar

    1998-01-01

    This paper describes the experimental setup for the evaluation of bursting smoke for anti-infrared role using SR-5000 spectroradiometer and a source of IR radiation (8-13 micrometer) using cadmium-mercury-telluride (CMI) detector cooled by liquid nitrogen. The particle size and shape of the powders used in the bursting smokes were determined microscopically using Carl Zeiss Jena Neophot- 21. Highest attenuation of 97 -lOO percent was produced for about 12 s using a mixture of bronze fl...

  8. Comportamiento de la cromósfera solar en la línea H-alfa durante el período enero/05-agosto/06

    Science.gov (United States)

    Missio, H.; Davoli, D.; Aquilano, R.

    Using the instrument at Observatorio Astronómico Municipal de Rosario (OAMR), we analyze the solar chromospheric activity during the period January/05-August/06. The instrument is a Carl Zeiss refractor telescope of 150 mm aperture and 2250 mm of focal distance with a monochromatic filter in the H-alpha line. We take as proxy for the solar activity the area covered by chromospheric ``plages''. The measurements are done using photographic registers. We describe our technique and the results obtained. We observe a decrease of solar activity that corresponds to the end of cycle 23. FULL TEXT IN SPANISH

  9. Observing Fluorescent Probes in Living Cells using a Low-Cost LED Flashlight Retrofitted to a Common Vintage Light Microscope

    Directory of Open Access Journals (Sweden)

    G. A. Babbitt

    2013-03-01

    Full Text Available While the application of molecular biological techniques based upon fluorescent probes has rapidly expanded over recent decades, the equipment cost of fluorescent microscopy has largely prevented its adoption in the college and high school classroom. We offer a simple solution to this problem by describing in detail how to build with simple tools, a fluorescent microscope using a common brand of colored LED flashlights and second-hand components of vintage Nikon microscopes. This extremely low cost solution is qualitatively compared to an expensive modern Zeiss system.

  10. Confocal scanning microscopy

    DEFF Research Database (Denmark)

    Bariani, Paolo

    This report is based on a metrological investigation on confocal microscopy technique carried out by Uffe Rolf Arlø Theilade and Paolo Bariani. The purpose of the experimental activity was twofold a metrological instrument characterization and application to assessment of rough PP injection moulded...... replicated topography. Confocal microscopy is seen to be a promising technique in metrology of microstructures. Some limitations with respect to surface metrology were found during the experiments. The experiments were carried out using a Zeiss LSM 5 Pascal microscope owned by the Danish Polymer Centre...

  11. Professor Ernst Bresslau, founder of the Zoology Departments at the Universities of Cologne and Sao Paulo: lessons to learn from his life history.

    Science.gov (United States)

    Pflüger, Hans-Joachim

    2017-06-01

    In this article, the life history of the founding father of the departments of Zoology at the Universities of Cologne and Sao Paulo, Prof. Ernst Bresslau, is described on occasion of the establishing of the "Ernst Bresslau Guest Professorship" at the University of Cologne. His main scientific achievements are discussed, in particular his research on the evolutionary origin of the mammary apparatus, in addition to his broad interest in biological topics. Among the many technical advancements that he introduced was the micro slow-motion camera developed together with the Zeiss Company which allowed to film ciliary beats at high speeds. Copyright © 2017 Elsevier GmbH. All rights reserved.

  12. Five HSFA telescopes and spectrographs - family silver or Greek gift?

    Science.gov (United States)

    Kotrč, P.

    2010-12-01

    A quarter-century ago five horizontal solar telescopes were delivered to Czechoslovakia from the Carl Zeiss Jena Company. Two of them have been installed in Ondrejov and one each in Hurbanovo, and Stará Lesná, with the last one reaching a mountain observatory near Alma Ata, Kazakhstan. The paper summarizes the brief history and characteristics of the instruments, different ways of their use, and realistic plans for their development. The users of the equipment received a dozen questions. The answers help us understand the importance of these instruments for the individual observatories.

  13. Application of stereo photogrammetric techniques for measuring African Elephants

    Directory of Open Access Journals (Sweden)

    A. J Hall-Martin

    1979-12-01

    Full Text Available Measurements of shoulder height and back length of African elephants were obtained by means of stereo photogrammetric techniques. A pair of Zeiss UMK 10/1318 cameras, mounted on a steel frame on the back of a vehicle, were used to photograph the elephants in the Addo Elephant National Park, Republic of South Africa. Several modifications of normal photogrammetry procedure applicable to the field situation (eg. control points and the computation of results (eg. relative orientation are briefly mentioned. Six elephants were immobilised after being photographed and the measurements obtained from them agreed within a range of 1 cm-10 cm with the photogrammetric measurements.

  14. Using laser technological unit ALTI "Karavella" for precision components of IEP production

    Science.gov (United States)

    Labin, N. A.; Chursin, A. D.; Paramonov, V. S.; Klimenko, V. I.; Paramonova, G. M.; Kolokolov, I. S.; Vinogradov, K. Y.; Betina, L. L.; Bulychev, N. A.; Dyakov, Yu. A.; Zakharyan, R. A.; Kazaryan, M. A.; Koshelev, K. K.; Kosheleva, O. K.; Grigoryants, A. G.; Shiganov, I. N.; Krasovskii, V. I.; Sachkov, V. I.; Plyaka, P. S.; Feofanov, I. N.; Chen, C.

    2015-12-01

    The paper revealed the using of industrial production equipment ALTI "Karavella-1", "Karavella-1M", "Karavella-2" and "Karavella-2M" precision components of IEP production [1-4]. The basis for the ALTI using in the IEP have become the positive results of research and development of technologies of foil (0.01-0.2 mm) and thin sheets (0.3-1 mm) materials micromachining by pulsed radiation CVL [5, 6]. To assess the micromachining quality and precision the measuring optical microscope (UHL VMM200), projection microscope (Mitutoyo PV5100) and Carl Zeiss microscope were used.

  15. DOLOČITEV POVRŠINSKE NAPETOSTI Z METODO KAPILARNEGA DVIGA DVOFAZNIH SISTEMOV

    OpenAIRE

    Kravanja, Gregor

    2014-01-01

    Namen magistrske naloge je bil postavitev merilne naprave in razvoj nove metode merjenja površinske napetosti s kapilarnim dvigom dvofaznih sistemov v okolici kritične točke. Za pridobitev natančnih in primerljivih meritev je bilo potrebno poznati natančni notranji premer tankih kapilar. Določili smo ga z metodo laserskega tipanja na nemški koordinatni merilni napravi ZEISS tipa UMC-850 s pomočjo merilne programske opreme CALYPSO 5.1.4. Za merjenje ravnotežne višine smo uporabili računalniški...

  16. Compilation of 1989 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G, H

    Science.gov (United States)

    1990-08-01

    Regulus calendula ! Eastern Bluebird 1 0 2 1 0 0 0 0 0 0 Sialia sialis 3 Veery 0 0 20 18 17 25 1 0 2 0 Catharus fuscescens Swainson’s Thrush 0 0 0 2 0 0...Regulus satrapa3 Ruby-crowned -Kinglet 1 0 2 1 0 0 0 0 3 0 Regulus calendula Veery 1 0- 12 4 2 2 0- 3 0 0 Catharus fuscescens -Swainson’s Thrush 0 0- 0...calculations, andIspecies determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil

  17. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed......PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...

  18. Gross anatomy of central nervous system in firefly, Pteroptyx tener (Coleoptera: Lampyridae)

    Science.gov (United States)

    Hudawiyah, Nur; Wahida, O. Nurul; Norela, S.

    2015-09-01

    This paper describes for the first time the organization and fine structure of the central nervous system (CNS) in the fireflies, Pteroptyx tener (Coleoptera: Lampyridae). The morphology of the CNS was examined by using Carl Zeiss AxioScope A1 photomicroscope with iSolution Lite software. Some specific structural features such as the localization of protocerebrum, deutocerebrum and tritocerebrum in the brain region were analyzed. Other than that, the nerve cord and its peripheral structure were also analyzed. This study suggests that, there is a very obvious difference between male and female central nervous system which illustrates that they may differ in function in controlling physiological and behavioral activities.

  19. Microstructure characterization of ceramic nuclear fuel

    International Nuclear Information System (INIS)

    Boehmert, J.; Gaessner, W.

    1984-08-01

    A system of characterizing methods is described based on quantitative ceramographic methods. This system is applicable in quality assurance of UO 2 nuclear fuel in small-scale production and for determining microstructural parameters in scientific investigations. The system is based essentially on the measuring of microstructural parameters by the methods of linear analysis by the VEB Carl Zeiss Jena EPIQUANT mechanical optical microstructural analyzer. It is completed by measuring the pore size using automatic the television analyzer QTM. Before the quantitative microstructural characterization, in each case the morphology of the structure is estimated qualitatively. (author)

  20. Fabrication of High Energy Density Tin/Carbon Anode Using Reduction Expansion Synthesis and Aerosol Through Plasma Techniques

    Science.gov (United States)

    2017-03-01

    his assistance with the analysis of samples using the TEM, as well as teaching me the safe use of XRD and SEM. Special thanks also go out to Ryan Adams...from the energy and construct a greyscale image for display. Figure 19. Zeiss NEON 40 SEM. Setup of SEM. Left: SEM and movement of stage using...delithiation cycling,” J. Electrochem. Soc., vol. 161, no. 11, pp. 3019– 3024, Jun. 2014. [20] P. L. Walker, Chemistry and Physics of Carbon: A Series of

  1. Ecdysis triggering hormone signaling in the yellow fever mosquito Aedes aegypti.

    Science.gov (United States)

    Dai, Li; Adams, Michael E

    2009-05-15

    At the end of each developmental stage, the yellow fever mosquito Aedes aegypti performs the ecdysis behavioral sequence, a precisely timed series of behaviors that culminates in shedding of the old exoskeleton. Here we describe ecdysis triggering hormone-immunoreactive Inka cells located at branch points of major tracheal trunks and loss of staining coincident with ecdysis. Peptides (AeaETH1, AeaETH2) purified from extracts of pharate 4th instar larvae have--PRXamide C-terminal amino acid sequence motifs similar to ETHs previously identified in moths and flies. Injection of synthetic AeaETHs induced premature ecdysis behavior in pharate larvae, pupae and adults. Two functionally distinct subtypes of ETH receptors (AeaETHR-A, AeaETHR-B) of A. aegypti are identified and show high sensitivity and selectivity to ETHs. Increased ETHR transcript levels and behavioral sensitivity to AeaETHs arising in the hours preceding the 4th instar larva-to-pupa ecdysis are correlated with rising ecdysteroid levels, suggesting steroid regulation of receptor gene expression. Our description of natural and ETH-induced ecdysis in A. aegypti should facilitate future approaches directed toward hormone-based interference strategies for control of mosquitoes as human disease vectors.

  2. Comparison of LED and Conventional Fluorescence Microscopy for Detection of Acid Fast Bacilli in a Low-Incidence Setting

    Science.gov (United States)

    Minion, Jessica; Pai, Madhukar; Ramsay, Andrew; Menzies, Dick; Greenaway, Christina

    2011-01-01

    Introduction Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. Methods In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS). Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. Results There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. Conclusions Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used. PMID:21811622

  3. Comparison of LED and conventional fluorescence microscopy for detection of acid fast bacilli in a low-incidence setting.

    Directory of Open Access Journals (Sweden)

    Jessica Minion

    Full Text Available INTRODUCTION: Light emitting diode fluorescence microscopes have many practical advantages over conventional mercury vapour fluorescence microscopes, which would make them the preferred choice for laboratories in both low- and high-resource settings, provided performance is equivalent. METHODS: In a nested case-control study, we compared diagnostic accuracy and time required to read slides with the Zeiss PrimoStar iLED, LW Scientific Lumin, and a conventional fluorescence microscope (Leica DMLS. Mycobacterial culture was used as the reference standard, and subgroup analysis by specimen source and organism isolated were performed. RESULTS: There was no difference in sensitivity or specificity between the three microscopes, and agreement was high for all comparisons and subgroups. The Lumin and the conventional fluorescence microscope were equivalent with respect to time required to read smears, but the Zeiss iLED was significantly time saving compared to both. CONCLUSIONS: Light emitting diode microscopy should be considered by all tuberculosis diagnostic laboratories, including those in high income countries, as a replacement for conventional fluorescence microscopes. Our findings provide support to the recent World Health Organization policy recommending that conventional fluorescence microscopy be replaced by light emitting diode microscopy using auramine staining in all settings where fluorescence microscopy is currently used.

  4. The effect of laser unit on photodynamic therapy spot size.

    Science.gov (United States)

    Ansari-Shahrezaei, Siamak; Binder, Susanne; Stur, Michael

    2011-01-01

    To determine the effect of the laser unit on photodynamic therapy (PDT) spot size. A calibrated Gullstrand-type model eye was used for this study. The axial length of the model eye was set to different values ranging from 22.2 to 27.0 mm, and the actual spot size from the laser console was recorded for treating a spot of 4 mm in the center of the artificial fundus using two different laser units (Coherent Opal laser; Coherent Inc, Santa Clara, California, USA and Zeiss Visulas laser; Carl Zeiss Meditec Inc, Dublin, California, USA) and two indirect contact laser lenses (Volk PDT laser lens and Volk Area Centralis lens; Volk Optical Inc, Mentor, Ohio, USA). From myopia to hyperopia, the total deviation from the intended spot size was -22.5% to -7.5% (Opal laser and PDT laser lens), and -17.5% to +2.5% (Visulas laser and PDT laser lens), -12.5% to +7.5% (Opal laser and Area Centralis lens), and -7.5% to +10% (Visulas laser and Area Centralis lens). The used laser unit has a significant effect on PDT spot size in this model. These findings may be important for optimizing PDT of choroidal neovascular lesions.

  5. Effect of Intracytoplasmic Sperm Injection (ICSI on Mouse Embryos Preimplantational Development

    Directory of Open Access Journals (Sweden)

    Claudia Cârstea

    2012-05-01

    Full Text Available It is known that the in vitro culture (IVC of preimplantation embryos is associated with changes in gene expression. It is however, not known if the method of fertilization affects the global pattern of gene expression. We compared the development of mouse blastocysts produced by intracytoplasmic sperm injection (ICSI versus blastocysts fertilized in vivo and cultured in vitro from the zygote stage (IVC. At the end of cultivation (96 hrs for blastocyst stage embryos, expanded blastocysts of each group were randomly selected, and ICM and total cells number were differentially stained. The total cell number of blastocysts was estimated by counting the total number of nuclei using DAPI staining. Cell number for inner cell mass (ICM was estimated by counting the OCT4 (POU5FL positive cells. Digitally recombined, composite images were analyzed using the Zeiss Axion Vision software and Zeiss Apotome. All 5–10 optical sections were divided using a standard grid over each layer to count all. Comparing the total cells and the ICM cells number, it appears that each method of fertilization has a unique pattern development. The developmental rate and the total cell number of the blastocyst were significantly lower in ICSI versus in vivo fertilized embryos which affect the embryonic developmental rate and the total cell number of blastocysts.

  6. Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking.

    Science.gov (United States)

    Pahuja, Natasha; Shetty, Rohit; Jayadev, Chaitra; Nuijts, Rudy; Hedge, Bharath; Arora, Vishal

    2015-01-01

    To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700) in keratoconus patients undergoing accelerated collagen crosslinking (ACXL) between epithelium on (epi-on) and epithelium off (epi-off). Intraoperative images were obtained during each of the procedures. Seven keratoconus patients underwent epi-on ACXL and four underwent epi-off ACXL. A software tool was developed using Microsoft.NET and Open Computer Vision (OpenCV) libraries for image analysis. Pre- and postprocedure images were analyzed for changes in the corneal hyperreflectance pattern as a measure of the depth of riboflavin penetration. The mean corneal hyperreflectance in the epi-on group was 12.97 ± 1.49 gray scale units (GSU) before instillation of riboflavin and 14.46 ± 2.09 GSU after AXCL (P = 0.019) while in the epi-off group it was 11.43 ± 2.68 GSU and 16.98 ± 8.49 GSU, respectively (P = 0.002). The average depth of the band of hyperreflectance in the epi-on group was 149.39 ± 15.63 microns and in the epi-off group it was 191.04 ± 32.18 microns. This novel in vivo, real time imaging study demonstrates riboflavin penetration during epi-on and epi-off ACXL.

  7. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    Directory of Open Access Journals (Sweden)

    Megan B. Goodman

    2015-08-01

    Full Text Available Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT and fundus auto fluorescence (FAF images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ, referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B consisted of 53 patients on CQ for more than 5 years. A 200 × 200 macula thickness map, 5-line raster SD-OCT on a Carl Zeiss Meditec Cirrus HD-OCT and FAF images on a Carl Zeiss Meditec Visucam 500 were recorded for 223 eyes. Images were reviewed independently, and then those of Groups A and B compared. Results: There were no statistically significant differences between Groups A and B. The criteria included the internal limiting membrane and the retinal pigment epithelium (ILM-RPE thickness, interdigitation zone integrity (p = 0.891, df = 1, χ² = 0.1876, ellipsoid zone integrity (p = 0.095, df = 2, χ² = 4.699 and FAF image irregularities (p = 0.479, df = 1, χ²= 4995978. Conclusion: The inclusion of SD-OCT and FAF as objective tests into the prescribed screening guidelines does not appear to simplify the detection of subclinical injury in patients on chloroquine treatment.

  8. Radiation dose determines the method for quantification of DNA double strand breaks

    International Nuclear Information System (INIS)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra; Todorović, Danijela

    2016-01-01

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  9. Objective detection of apoptosis in rat renal tissue sections using light microscopy and free image analysis software with subsequent machine learning: Detection of apoptosis in renal tissue.

    Science.gov (United States)

    Macedo, Nayana Damiani; Buzin, Aline Rodrigues; de Araujo, Isabela Bastos Binotti Abreu; Nogueira, Breno Valentim; de Andrade, Tadeu Uggere; Endringer, Denise Coutinho; Lenz, Dominik

    2017-02-01

    The current study proposes an automated machine learning approach for the quantification of cells in cell death pathways according to DNA fragmentation. A total of 17 images of kidney histological slide samples from male Wistar rats were used. The slides were photographed using an Axio Zeiss Vert.A1 microscope with a 40x objective lens coupled with an Axio Cam MRC Zeiss camera and Zen 2012 software. The images were analyzed using CellProfiler (version 2.1.1) and CellProfiler Analyst open-source software. Out of the 10,378 objects, 4970 (47,9%) were identified as TUNEL positive, and 5408 (52,1%) were identified as TUNEL negative. On average, the sensitivity and specificity values of the machine learning approach were 0.80 and 0.77, respectively. Image cytometry provides a quantitative analytical alternative to the more traditional qualitative methods more commonly used in studies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Low-cost, smartphone based frequency doubling technology visual field testing using virtual reality (Conference Presentation)

    Science.gov (United States)

    Alawa, Karam A.; Sayed, Mohamed; Arboleda, Alejandro; Durkee, Heather A.; Aguilar, Mariela C.; Lee, Richard K.

    2017-02-01

    Glaucoma is the leading cause of irreversible blindness worldwide. Due to its wide prevalence, effective screening tools are necessary. The purpose of this project is to design and evaluate a system that enables portable, cost effective, smartphone based visual field screening based on frequency doubling technology. The system is comprised of an Android smartphone to display frequency doubling stimuli and handle processing, a Bluetooth remote for user input, and a virtual reality headset to simulate the exam. The LG Nexus 5 smartphone and BoboVR Z3 virtual reality headset were used for their screen size and lens configuration, respectively. The system is capable of running the C-20, N-30, 24-2, and 30-2 testing patterns. Unlike the existing system, the smartphone FDT tests both eyes concurrently by showing the same background to both eyes but only displaying the stimulus to one eye at a time. Both the Humphrey Zeiss FDT and the smartphone FDT were tested on five subjects without a history of ocular disease with the C-20 testing pattern. The smartphone FDT successfully produced frequency doubling stimuli at the correct spatial and temporal frequency. Subjects could not tell which eye was being tested. All five subjects preferred the smartphone FDT to the Humphrey Zeiss FDT due to comfort and ease of use. The smartphone FDT is a low-cost, portable visual field screening device that can be used as a screening tool for glaucoma.

  11. PERFLUOROCARBON LIQUIDS' ABILITY TO PROTECT THE MACULA FROM INTRAOCULAR DROPPING OF METALLIC FOREIGN BODIES: A Model Eye Study.

    Science.gov (United States)

    Shah, Chirag M; Gentile, Ronald C; Mehta, Mitul C

    2016-07-01

    To examine the utility of perfluoro-n-octane (PFO) in balanced salt solution (BSS) to shield the macula from the impact of dropped metallic intraocular foreign bodies (IOFBs) by modeling scenarios in which they may fall during surgical removal. Model eyes were filled with various fluid mixtures (Group 1: 10% PFO/90% BSS; Group 2: 100% BSS; Group 3: 100% PFO; Group 4: 10% PFO/90% air; Group 5: 10% BSS/90% air). In Groups 1, 4, and 5, the 10% fluid volume covered the theoretical macula. For each fluid mixture, up to 30 IOFB drop scenarios were performed for each of the 5 sample IOFBs from 3 locations. Trajectories were recorded using a camera attached to a Zeiss operating microscope (Carl Zeiss, Jena, Germany). The percentages of IOFBs impacting the macula were calculated and Fisher exact test was used to assess differences. In Group 1, 93% (417/450) of the dropped IOFBs were deflected by the PFO-BSS interface compared with 0% (0/500) in Groups 2, 3, 4, and 5 (P macula in 30% of tests when dropped from the superior posterior segment (P < 0.01), all other IOFBs (2.8-13.4 mg) were deflected by the PFO-BSS interface in 100% of Group 1 drops (P < 0.01). As demonstrated by these simulations, the PFO-BSS interface can deflect IOFBs dropped during surgery in a wide range of scenarios, especially when the IOFB is of lower mass.

  12. INTRASURGICAL MICROSCOPE-INTEGRATED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY-ASSISTED MEMBRANE PEELING.

    Science.gov (United States)

    Falkner-Radler, Christiane I; Glittenberg, Carl; Gabriel, Max; Binder, Susanne

    2015-10-01

    To evaluate microscope-integrated intrasurgical spectral domain optical coherence tomography during macular surgery in a prospective monocenter study. Before pars plana vitrectomy and before, during, and after membrane peeling, 512 × 128 macular cube scans were performed using a Carl Zeiss Meditec Cirrus high-definition OCT system adapted to the optical pathway of a Zeiss OPMI VISU 200 surgical microscope and compared with retinal staining. The study included 51 patients with epiretinal membranes, with 8 of those having additional lamellar macular holes, 11 patients with vitreomacular traction, and 8 patients with full-thickness macular holes. Intraoperative spectral domain optical coherence tomography allowed performing membrane peeling without using retinal dyes in 40% of cases (28 of 70 patients). No residual membranes were found in 94.3% of patients (66 of 70 patients) in intrasurgical spectral domain optical coherence tomography and subsequent (re)staining. In patients with vitreomacular traction, intrasurgical spectral domain optical coherence tomography scans facilitated decisions on the need for an intraocular tamponade after membrane peeling. Intraoperative spectral domain optical coherence tomography was comparable with retinal dyes in confirming success after membrane peeling. However, the visualization of flat membranes was better after staining.

  13. Ants Colony Optimisation of a Measuring Path of Prismatic Parts on a CMM

    Directory of Open Access Journals (Sweden)

    Stojadinovic Slavenko M.

    2016-03-01

    Full Text Available This paper presents optimisation of a measuring probe path in inspecting the prismatic parts on a CMM. The optimisation model is based on: (i the mathematical model that establishes an initial collision-free path presented by a set of points, and (ii the solution of Travelling Salesman Problem (TSP obtained with Ant Colony Optimisation (ACO. In order to solve TSP, an ACO algorithm that aims to find the shortest path of ant colony movement (i.e. the optimised path is applied. Then, the optimised path is compared with the measuring path obtained with online programming on CMM ZEISS UMM500 and with the measuring path obtained in the CMM inspection module of Pro/ENGINEER® software. The results of comparing the optimised path with the other two generated paths show that the optimised path is at least 20% shorter than the path obtained by on-line programming on CMM ZEISS UMM500, and at least 10% shorter than the path obtained by using the CMM module in Pro/ENGINEER®.

  14. Radiation dose determines the method for quantification of DNA double strand breaks

    Energy Technology Data Exchange (ETDEWEB)

    Bulat, Tanja; Keta, Olitija; Korićanac, Lela; Žakula, Jelena; Petrović, Ivan; Ristić-Fira, Aleksandra [University of Belgrade, Vinča Institute of Nuclear Sciences, Belgrade (Serbia); Todorović, Danijela, E-mail: dtodorovic@medf.kg.ac.rs [University of Kragujevac, Faculty of Medical Sciences, Kragujevac (Serbia)

    2016-03-15

    Ionizing radiation induces DNA double strand breaks (DSBs) that trigger phosphorylation of the histone protein H2AX (γH2AX). Immunofluorescent staining visualizes formation of γH2AX foci, allowing their quantification. This method, as opposed to Western blot assay and Flow cytometry, provides more accurate analysis, by showing exact position and intensity of fluorescent signal in each single cell. In practice there are problems in quantification of γH2AX. This paper is based on two issues: the determination of which technique should be applied concerning the radiation dose, and how to analyze fluorescent microscopy images obtained by different microscopes. HTB140 melanoma cells were exposed to γ-rays, in the dose range from 1 to 16 Gy. Radiation effects on the DNA level were analyzed at different time intervals after irradiation by Western blot analysis and immunofluorescence microscopy. Immunochemically stained cells were visualized with two types of microscopes: AxioVision (Zeiss, Germany) microscope, comprising an ApoTome software, and AxioImagerA1 microscope (Zeiss, Germany). Obtained results show that the level of γH2AX is time and dose dependent. Immunofluorescence microscopy provided better detection of DSBs for lower irradiation doses, while Western blot analysis was more reliable for higher irradiation doses. AxioVision microscope containing ApoTome software was more suitable for the detection of γH2AX foci. (author)

  15. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    Science.gov (United States)

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  16. Magnetic observations at Geophysical Observatory Paratunka IKIR FEB RAS: tasks, possibilities and future prospects

    Science.gov (United States)

    Khomutov, Sergey Y.

    2017-10-01

    Continuous magnetic measurements at Geophysical Observatory "Paratunka" (PET) of IKIR FEB RAS are performed since 1967. In the new millennium analogue magnetometers were modernized to digital, the technologies of absolute observations were changed, the data processing was completely transferred to computers, and the status of INTERMAGNET observatory was obtained. Currently, the observatory uses the following magnetometers: (a) for absolute observations - DIflux LEMI-203 (theodolite 3T2KP) and Mag-01 (theodolite Wild-T1), Overhauser magnetometers POS-1 and GSM-19W; (b) for variation measurements - fluxgate magnetometers FGE-DTU, FRG-601 and MAGDAS (installed under international agreements of IKIR), vector magnetometers dIdD GSM-19FD and POS-4 with Overhauser sensors and coil systems, scalar magnetometer GSM-90 and induction magnetometer STELAB. During Spring-Autumn season dIdD also is installed at remote station "Karymshina" at distance of 15 km from Observatory. There is monitoring system for monitoring of conditions in which magnetic observations are performed, including the semi-professional weather stations Davis Vantage Pro2 and WS2000 and a network of digital temperature sensors DS19B20 located at various points in magnetic pavilions and outdoor. All measurements are synchronized with the UTC. The results of observations are collected by the IKIR data server from the recorders and loggers, including in real-time. Specialized software was developed (based on MATLAB and Octave packages), which allows automatic and semi-automatic processing of data, the comparison of the results from different magnetometers and presenting final data in formats, defined by international standards, including INTERMAGNET. Significant efforts of observatory staff are direct to archive (raw) magnetic data, a significant part of which has not been entirely processed, is not presented in international data centers and is still not available to the scientific community. Digital images of

  17. Magnetic observations at Geophysical Observatory Paratunka IKIR FEB RAS: tasks, possibilities and future prospects

    Directory of Open Access Journals (Sweden)

    Khomutov Sergey Y.

    2017-01-01

    Full Text Available Continuous magnetic measurements at Geophysical Observatory “Paratunka” (PET of IKIR FEB RAS are performed since 1967. In the new millennium analogue magnetometers were modernized to digital, the technologies of absolute observations were changed, the data processing was completely transferred to computers, and the status of INTERMAGNET observatory was obtained. Currently, the observatory uses the following magnetometers: (a for absolute observations – DIflux LEMI-203 (theodolite 3T2KP and Mag-01 (theodolite Wild-T1, Overhauser magnetometers POS-1 and GSM-19W; (b for variation measurements – fluxgate magnetometers FGE-DTU, FRG-601 and MAGDAS (installed under international agreements of IKIR, vector magnetometers dIdD GSM-19FD and POS-4 with Overhauser sensors and coil systems, scalar magnetometer GSM-90 and induction magnetometer STELAB. During Spring-Autumn season dIdD also is installed at remote station “Karymshina” at distance of 15 km from Observatory. There is monitoring system for monitoring of conditions in which magnetic observations are performed, including the semi-professional weather stations Davis Vantage Pro2 and WS2000 and a network of digital temperature sensors DS19B20 located at various points in magnetic pavilions and outdoor. All measurements are synchronized with the UTC. The results of observations are collected by the IKIR data server from the recorders and loggers, including in real-time. Specialized software was developed (based on MATLAB and Octave packages, which allows automatic and semi-automatic processing of data, the comparison of the results from different magnetometers and presenting final data in formats, defined by international standards, including INTERMAGNET. Significant efforts of observatory staff are direct to archive (raw magnetic data, a significant part of which has not been entirely processed, is not presented in international data centers and is still not available to the scientific

  18. Archaeoastronomical Fieldwork in Peru

    Science.gov (United States)

    Zawaski, Mike J.; Malville, J.

    2006-09-01

    During June-July 2005, sets of 14 horizon photographs were obtained at 10 major monumental sites of the Inca as identified in Hemming and Ranney (1982) . The photographs were combined to yield complete 360o panoramas at each of the sites. To calibrate the panoramas a Wild T-2 theodolite was used to obtain 5 pairs of altitude/azimuth measurements of the Sun at each site. The standard deviation of multiple determinations of true north was typically 0.25'to 0.5'. As a check on the sun sights, a line-of-sight azimuth was also established with GPS measurements at each site. Agreement between these baselines and the sun sights are satisfactory. We find evidence of June solstice and/or Pleiades orientations at Llactapata, Sayhuite, and Ollantaytambo; cardinal orientation at Vilcashuman; June solstice established by horizon towers above Urubamba; and both zenith and anti-zenith solar alignments at the tower of Muyuc Marca of Sacsayhuman. Terracing, walls, and water features at Ollantaytambo suggest interest in both June and December solstices. The statistical significance of these orientations is evaluated. A permit was issued by the office of the Institute Cultura National in Cusco for field work at all of these sites. This work was undertook as partial fulfillment of the requirement for a MA degree in Earth Sciences at the University of Northern Colorado. Funding was provided by Sigma Xi and The University of Northern Colorado. Hemming, J. and E. Ranney. 1982. Monuments of the Inca, Boston: Little, Brown

  19. An automatic DI-flux at the Livingston Island geomagnetic observatory, Antarctica: requirements and lessons learned

    Science.gov (United States)

    Marsal, Santiago; José Curto, Juan; Torta, Joan Miquel; Gonsette, Alexandre; Favà, Vicent; Rasson, Jean; Ibañez, Miquel; Cid, Òscar

    2017-07-01

    The DI-flux, consisting of a fluxgate magnetometer coupled with a theodolite, is used for the absolute manual measurement of the magnetic field angles in most ground-based observatories worldwide. Commercial solutions for an automated DI-flux have recently been developed by the Royal Meteorological Institute of Belgium (RMI), and are practically restricted to the AutoDIF and its variant, the GyroDIF. In this article, we analyze the pros and cons of both instruments in terms of its suitability for installation at the partially manned geomagnetic observatory of Livingston Island (LIV), Antarctica. We conclude that the GyroDIF, even if it is less accurate and more power demanding, is more suitable than the AutoDIF for harsh conditions due to the simpler infrastructure that is necessary. Power constraints in the Spanish Antarctic Station Juan Carlos I (ASJI) during the unmanned season require an energy-efficient design of the thermally regulated box housing the instrument as well as thorough power management. Our experiences can benefit the geomagnetic community, which often faces similar challenges.

  20. An automatic DI-flux at the Livingston Island geomagnetic observatory, Antarctica: requirements and lessons learned

    Directory of Open Access Journals (Sweden)

    S. Marsal

    2017-07-01

    Full Text Available The DI-flux, consisting of a fluxgate magnetometer coupled with a theodolite, is used for the absolute manual measurement of the magnetic field angles in most ground-based observatories worldwide. Commercial solutions for an automated DI-flux have recently been developed by the Royal Meteorological Institute of Belgium (RMI, and are practically restricted to the AutoDIF and its variant, the GyroDIF. In this article, we analyze the pros and cons of both instruments in terms of its suitability for installation at the partially manned geomagnetic observatory of Livingston Island (LIV, Antarctica. We conclude that the GyroDIF, even if it is less accurate and more power demanding, is more suitable than the AutoDIF for harsh conditions due to the simpler infrastructure that is necessary. Power constraints in the Spanish Antarctic Station Juan Carlos I (ASJI during the unmanned season require an energy-efficient design of the thermally regulated box housing the instrument as well as thorough power management. Our experiences can benefit the geomagnetic community, which often faces similar challenges.

  1. High-precision optical systems with inexpensive hardware: a unified alignment and structural design approach

    Science.gov (United States)

    Winrow, Edward G.; Chavez, Victor H.

    2011-09-01

    High-precision opto-mechanical structures have historically been plagued by high costs for both hardware and the associated alignment and assembly process. This problem is especially true for space applications where only a few production units are produced. A methodology for optical alignment and optical structure design is presented which shifts the mechanism of maintaining precision from tightly toleranced, machined flight hardware to reusable, modular tooling. Using the proposed methodology, optical alignment error sources are reduced by the direct alignment of optics through their surface retroreflections (pips) as seen through a theodolite. Optical alignment adjustments are actualized through motorized, sub-micron precision actuators in 5 degrees of freedom. Optical structure hardware costs are reduced through the use of simple shapes (tubes, plates) and repeated components. This approach produces significantly cheaper hardware and more efficient assembly without sacrificing alignment precision or optical structure stability. The design, alignment plan and assembly of a 4" aperture, carbon fiber composite, Schmidt-Cassegrain concept telescope is presented.

  2. Monitoring of the Nirano Mud Volcanoes Regional Natural Reserve (North Italy using Unmanned Aerial Vehicles and Terrestrial Laser Scanning

    Directory of Open Access Journals (Sweden)

    Tommaso Santagata

    2017-09-01

    Full Text Available In the last years, measurement instruments and techniques for three-dimensional mapping as Terrestrial Laser Scanning (TLS and photogrammetry from Unmanned Aerial Vehicles (UAV are being increasingly used to monitor topographic changes on particular geological features such as volcanic areas. In addition, topographic instruments such as Total Station Theodolite (TST and GPS receivers can be used to obtain precise elevation and coordinate position data measuring fixed points both inside and outside the area interested by volcanic activity. In this study, the integration of these instruments has helped to obtain several types of data to monitor both the variations in heights of extrusive edifices within the mud volcano field of the Nirano Regional Natural Reserve (Northern Italy, as well as to study the mechanism of micro-fracturing and the evolution of mud flows and volcanic cones with very high accuracy by 3D point clouds surface analysis and digitization. The large amount of data detected were also analysed to derive morphological information about mud-cracks and surface roughness. This contribution is focused on methods and analysis performed using measurement instruments as TLS and UAV to study and monitoring the main volcanic complexes of the Nirano Natural Reserve as part of a research project, which also involves other studies addressing gases and acoustic measurements, mineralogical and paleontological analysis, organized by the University of Modena and Reggio Emilia in collaboration with the Municipality of Fiorano Modenese.

  3. Optical tools and techniques for aligning solar payloads with the SPARCS control system. [Solar Pointing Aerobee Rocket Control System

    Science.gov (United States)

    Thomas, N. L.; Chisel, D. M.

    1976-01-01

    The success of a rocket-borne experiment depends not only on the pointing of the attitude control system, but on the alignment of the attitude control system to the payload. To ensure proper alignment, special optical tools and alignment techniques are required. Those that were used in the SPARCS program are described and discussed herein. These tools include theodolites, autocollimators, a 38-cm diameter solar simulator, a high-performance 1-m heliostat to provide a stable solar source during the integration of the rocket payload, a portable 75-cm sun tracker for use at the launch site, and an innovation called the Solar Alignment Prism. Using the real sun as the primary reference under field conditions, the Solar Alignment Prism facilitates the coalignment of the attitude sun sensor with the payload. The alignment techniques were developed to ensure the precise alignment of the solar payloads to the SPARCS attitude sensors during payload integration and to verify the required alignment under field conditions just prior to launch.

  4. A brief history of the evolution of surveying and its role in today´s world | Uma breve história da evolução do levantamento e seu papel no mundo de hoje

    Directory of Open Access Journals (Sweden)

    Rafael Silva Anjos

    2016-06-01

    The land surveying appeared millennia ago as a measurement technique for large human constructions. Before all its historical process that science has gone through phases of improvement that has become quite popular nowadays. Since the first measurement instruments as the Egyptian Groma to the use of theodolites and total stations integrated with all kinds of instruments of spatial data acquisition (GNSS receivers, aerial photographs, multispectral satellites the surveying methods now form the basis for various types of research. Quite confused with other sciences, such as Geodesy, Topography makes a more limited planialtimetric survey. That is why their applications are given in areas such as civil engineering, architecture, agronomy to architecture. If we know the differentiation of these key concepts related to topography we can to understand the applicability of this science, helping researchers in various fields. It is in this context, that the present paper aims to address the main concepts related to topography and the main activities human using this technique, making a historical approach since the beginning of its use to the instruments most widely used in the survey.

  5. Jean Gervaise 1921 -2007

    CERN Multimedia

    2007-01-01

    Jean Gervaise, a pioneer of metrology at CERN, passed away on 10 April. A French geodesist, he was behind the creation and development of CERN's metrology group and was a consistently fervent advocate of innovation to meet the increasingly demanding alignment needs of the accelerators and detectors. Under his leadership, metrology at CERN acquired international renown. Jean Gervaise taking measurements with invar wire and a theodolite on a pillar at the PS. In spite of the disruptions caused by the second world war, Jean Gervaise was able to complete an engineering degree at the Ecole nationale des Sciences géographiques in Paris, which led to a first job in the prestigious Geodesy Department of the Institut géographique national (IGN). This 'queen of disciplines', as he called it, is the most scientific and most complex of the branches of cartography, offering opportunities for exciting and varied - sometimes highly adventurous - missions at home and abroad. The rich experience he acquired here helped to...

  6. Alignment of the stanford linear collider Arcs

    International Nuclear Information System (INIS)

    Pitthan, R.; Bell, B.; Friedsam, H.

    1987-01-01

    The alignment of the Arcs for the Stanford Linear Collider at SLAC has posed problems in accelerator survey and alignment not encountered before. These problems come less from the tight tolerances of 0.1 mm, although reaching such a tight statistically defined accuracy in a controlled manner is difficult enough, but from the absence of a common reference plane for the Arcs. Traditional circular accelerators, including HERA and LEP, have been designed in one plane referenced to local gravity. For the SLC Arcs no such single plane exists. Methods and concepts developed to solve these and other problems, connected with the unique design of SLC, range from the first use of satellites for accelerator alignment, use of electronic laser theodolites for placement of components, computer control of the manual adjustment process, complete automation of the data flow incorporating the most advanced concepts of geodesy, strict separation of survey and alignment, to linear principal component analysis for the final statistical smoothing of the mechanical components

  7. Digital Documentation of Ships in Cultural Heritage: a European Review

    Science.gov (United States)

    Colson, A.

    2017-08-01

    Ships of different shapes and times are lying in harbours, on land or in museums, all over the world. Our aim with this paper was to review work done on digital documentation of ships in Cultural Heritage based on different initiatives in Europe using Coordinate Measuring Machine (Newport Ship and Doel 1); Total Station Theodolite (Vasa and Mary-Rose) and Laser scanning (LaScanMar and Traditional boats of Ireland). Our results showed that some discrepancy exist between the projects, in terms of techniques and expertise at hand. Furthermore, few guidelines have been in practice but only for Archaeology and Ethnology. However, no standards are existing. Three focuses have emerged: documentation of single ship elements, monitoring of the long-term deformation processes and the documentation of collections of ships. We discussed the diversity of expert's background and the complexity of comparability between projects. In conclusion, guidelines are necessary to enable a common ground for all professions to work together, e.g. in Architecture. This path must be taken now for digital documentation of ships, if not information and knowledge will be lost on the way.

  8. THE USE OF GEOTECHNOLOGY IN ANALYSIS OF ENVIRONMENTAL IMPACTS IN SALTO VENTOSO (FARROUPILHA/RS

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Teixeira

    2012-03-01

    Full Text Available This paper is the outcome of a survey on environmental impacts due to visitors in a tourist attraction, using geotechnology as a tool. The study was carried out at Salto Ventoso, Farroupilha, Rio Grande do Sul State (Brazil, a tourist attraction with major importance for the region. At the site, a private area, the attraction is a 60 meters (197 feet height cascade and its scenic landscape. Visitors can also hike through the trail that goes behind the waterfall. The trail was mapped using GPS (Global Positioning System and theodolite, and divided into twelve sections, which were evaluated on the issues of declivity, width, damage to natural resources and infrastructure, drainage problems, number of unofficial trails and amount of waste. The results showed that the site presents a series of environmental impacts resulting from both lack of planning and great amount of visitors. Some strategies for managing the site would be the installation of safety and signing infrastructure, as well as a work on environmental awareness of the visitors and their impacts on site.

  9. Alignment of the Stanford Linear Collider Arcs: Concepts and results

    International Nuclear Information System (INIS)

    Pitthan, R.; Bell, B.; Friedsam, H.; Pietryka, M.; Oren, W.; Ruland, R.

    1987-02-01

    The alignment of the Arcs for the Stanford Linear Collider at SLAC has posed problems in accelerator survey and alignment not encountered before. These problems come less from the tight tolerances of 0.1 mm, although reaching such a tight statistically defined accuracy in a controlled manner is difficult enough, but from the absence of a common reference plane for the Arcs. Traditional circular accelerators, including HERA and LEP, have been designed in one plane referenced to local gravity. For the SLC Arcs no such single plane exists. Methods and concepts developed to solve these and other problems, connected with the unique design of SLC, range from the first use of satellites for accelerator alignment, use of electronic laser theodolites for placement of components, computer control of the manual adjustment process, complete automation of the data flow incorporating the most advanced concepts of geodesy, strict separation of survey and alignment, to linear principal component analysis for the final statistical smoothing of the mechanical components

  10. Methods for acquiring data on terrain geomorphology, course geometry and kinematics of competitors' runs in alpine skiing: a historical review.

    Science.gov (United States)

    Erdmann, Włodzimierz S; Giovanis, Vassilis; Aschenbrenner, Piotr; Kiriakis, Vaios; Suchanowski, Andrzej

    2017-01-01

    This paper aims at the description and comparison of methods of topographic analysis of racing courses at all disciplines of alpine skiing sports for the purposes of obtaining: terrain geomorphology (snowless and with snow), course geometry, and competitors' runs. The review presents specific methods and instruments according to the order of their historical appearance as follows: (1) azimuth method with the use of a compass, tape and goniometer instruments; (2) optical method with geodetic theodolite, laser and photocells; (3) triangulation method with the aid of a tape and goniometer; (4) image method with the use of video cameras; (5) differential global positioning system and carrier phase global positioning system methods. Described methods were used at homologation procedure, at training sessions, during competitions of local level and during International Ski Federation World Championships or World Cups. Some methods were used together. In order to provide detailed data on course setting and skiers' running it is recommended to analyse course geometry and kinematics data of competitors' running for all important competitions.

  11. Analysis of Double Meridian Distance for a Closed Traverse Area towards Developing a Contour Map and Land Title

    Directory of Open Access Journals (Sweden)

    T. U. Ganiron Jr

    2014-07-01

    Full Text Available This research aimed to analyze double meridian distance for a closed traverse area in developing a land title for a propose gymnasium in Qassim University. Theodolite, leveling rod and steel tape plays an important role in measuring elevations, bearings and distances of the boundaries of a lot. Contour map is necessary to determine the traces of level surfaces of successive elevation. This will enable to identify the type of contour map and type of contour lines necessary for this project. Corel draw software is used to draw contour map and guide to interpret the significance of the variables. It is essential to check the error of closure for interior angles and for both latitude and departure before applying the Double Meridian Distance (DMD method to obtain the total area of the lot. Technical descriptions of the land such as distance, bearing, boundaries and area are necessary to visualize the shape & exact location of the land. Developing a land title will be obtained using the technical descriptions of the lot in preparation for the type of gymnasium necessary for Qassim University.

  12. Newly devised infrared radiometer (ERI type IR ground scanner) and the surface temperature of the Mihara crater, O-shima

    Energy Technology Data Exchange (ETDEWEB)

    Shimozuru, D [Earthquake Res. Inst., Univ. of Tokyo; Kagiyama, T

    1976-10-01

    The infrared radiometer, a remote sensing tool, can be successfully used to measure the surface temperature of a volcanic or geothermal area. Many of these devices are available commercially for industrial use but their application to volcano observations is limited due to a wide field of view which prohibits detailed examination of specific points. A commercial radiometer was mounted on a balloon theodolite with an electrically driven rotating base. A telescope was attached to the radiometer to permit monitoring of the field of view. Radiometer output can be recorded either on a magnetic tape data recorder or a strip chart recorder. The device is also useful for continuous monitoring of the temperature of a vent or fumarole. The observed temperatures are dependent upon the wave length of actual spatial temperature distribution, the field of view and the scanning speed. Detailed information of both a theoretical and an experimental nature is provided. The improved radiometer was utilized to observe surface temperature in the caldera of Miharayama, Oshima in March, 1976. It was found that the vent temperature was markedly lower than had previously been recorded, as was the average surface temperature.

  13. Status report on the alignment activities at SLAC

    International Nuclear Information System (INIS)

    Le Cocq, Catherine; Fuss, Brian; Ruland, Robert

    2003-01-01

    This report mainly focuses on the Alignment Engineering Group, which deals with all aspects of activities involving surveying and alignment at SLAC (Stanford Linear Accelerator Center). These activities are field work, ongoing studies and mapping effort. The majority of fieldwork at SLAC is initiated by the various current physics experiments. As PEP-II switched into operational mode, another major project was fully ramping up: SPEAR. The Stanford Synchrotron Radiation Laboratory (SSRL) had been preparing the upgrade SPEAR3 (3 GeV, 200 mA). Currently the effort has been to remap the entire SPEAR2 ring including existing magnets but also to map and tie in the connected booster ring. Laser trackers, total stations, and digital levels were used and substantial post processing was necessary to tie everything together. In parallel with field works, several instrumentation studies are in progress on laser tracker and total station, leveling instrumentation and gyro theodolites. Further enhancements have been included in the core network analysis package used at SLAC (LEGO). To keep up with the new installation, SLAC is undergoing an update of its site map. Overall this is a very interesting and dynamic time at SLAC, which celebrated its 40th anniversary on October 2nd 2002. (Y. Tanaka)

  14. Object tracking with robotic total stations: Current technologies and improvements based on image data

    Science.gov (United States)

    Ehrhart, Matthias; Lienhart, Werner

    2017-09-01

    The importance of automated prism tracking is increasingly triggered by the rising automation of total station measurements in machine control, monitoring and one-person operation. In this article we summarize and explain the different techniques that are used to coarsely search a prism, to precisely aim at a prism, and to identify whether the correct prism is tracked. Along with the state-of-the-art review, we discuss and experimentally evaluate possible improvements based on the image data of an additional wide-angle camera which is available for many total stations today. In cases in which the total station's fine aiming module loses the prism, the tracked object may still be visible to the wide-angle camera because of its larger field of view. The theodolite angles towards the target can then be derived from its image coordinates which facilitates a fast reacquisition of the prism. In experimental measurements we demonstrate that our image-based approach for the coarse target search is 4 to 10-times faster than conventional approaches.

  15. Astronomical Orientation Method Based on Lunar Observations Utilizing Super Wide Field of View

    Directory of Open Access Journals (Sweden)

    PU Junyu

    2018-04-01

    Full Text Available In this paper,astronomical orientation is achieved by observing the moon utilizing camera with super wide field of view,and formulae are deduced in detail.An experiment based on real observations verified the stability of the method.In this experiment,after 15 minutes' tracking shoots,the internal precision could be superior to ±7.5" and the external precision could approximately reach ±20".This camera-based method for astronomical orientation can change the traditional mode (aiming by human eye based on theodolite,thus lowering the requirements for operator's skill to some extent.Furthermore,camera with super wide field of view can realize the function of continuous tracking shoots on the moon without complicated servo control devices.Considering the similar existence of gravity on the moon and the earth's phase change when observed from the moon,once the technology of self-leveling is developed,this method can be extended to orientation for lunar rover by shooting the earth.

  16. Generation of human scFvs antibodies recognizing a prion protein epitope expressed on the surface of human lymphoblastoid cells

    Directory of Open Access Journals (Sweden)

    Imperiale Valentina

    2007-07-01

    Full Text Available Abstract Background A hallmark of prion disease is the transformation of normal cellular prion protein (PrPc into an infectious disease-associated isoform, (PrPsc. Anti-prion protein monoclonal antibodies are invaluable for structure-function studies of PrP molecules. Furthermore recent in vitro and in vivo studies indicate that anti-PrP monoclonal antibodies can prevent the incorporation of PrPc into propagating prions. In the present article, we show two new human phage antibodies, isolated on recombinant hamster prion protein (rHaPrP. Results We adopted an antibody phage display strategy to isolate specific human antibodies directed towards rHaPrP which has been used as a bait for panning the synthetic ETH-2 antibody phage library. Two phage antibodies clones named MA3.B4 and MA3.G3 were isolated and characterized under genetic biochemical and immunocytochemical aspects. The clones were found to recognize the prion protein in ELISA studies. In flow-cytometry studies, these human single chain Fragment variable (scFv phage-antibodies show a well defined pattern of reactivity on human lymphoblastoid and myeloid cells. Conclusion Sequence analysis of the gene encoding for the antibody fragments and antigen recognition patterns determined by flow-cytometry analysis indicate that the isolated scFvs recognize novel epitopes in the PrPc molecule. These new anti PrPc human antibodies are unique reagents for prion protein detection and may represent a biologic platform to develop new reagents to treat PrPsc associated disease.

  17. Role of Dispersive Fluorous Interaction in the Solvation Dynamics of the Perfluoro Group Containing Molecules.

    Science.gov (United States)

    Mondal, Saptarsi; Chaterjee, Soumit; Halder, Ritaban; Jana, Biman; Singh, Prashant Chandra

    2017-08-17

    Perfluoro group containing molecules possess an important self-aggregation property through the fluorous (F···F) interaction which makes them useful for diverse applications such as medicinal chemistry, separation techniques, polymer technology, and biology. In this article, we have investigated the solvation dynamics of coumarin-153 (C153) and coumarin-6H (C6H) in ethanol (ETH), 2-fluoroethanol (MFE), and 2,2,2-trifluoroethanol (TFE) using the femtosecond upconversion technique and molecular dynamics (MD) simulation to understand the role of fluorous interaction between the solute and solvent molecules in the solvation dynamics of perfluoro group containing molecules. The femtosecond upconversion data show that the time scales of solvation dynamics of C6H in ETH, MFE, and TFE are approximately the same whereas the solvation dynamics of C153 in TFE is slow as compared to that of ETH and MFE. It has also been observed that the time scale of solvation dynamics of C6H in ETH and MFE is higher than that of C153 in the same solvents. MD simulation results show a qualitative agreement with the experimental data in terms of the time scale of the slow components of the solvation for all the systems. The experimental and simulation studies combined lead to the conclusion that the solvation dynamics of C6H in all solvents as well as C153 in ETH and MFE is mostly governed by the charge distribution of ester moieties (C═O and O) of dye molecules whereas the solvation of C153 in TFE is predominantly due to the dispersive fluorous interaction (F···F) between the perfluoro groups of the C153 and solvent molecules.

  18. Application of differential interference contrast with inverted microscopes to the in vitro perfused nephron.

    Science.gov (United States)

    Horster, M; Gundlach, H

    1979-12-01

    The study of in vitro perfused individual nephron segments requires a microscope which provides: (1) easy access to the specimen for measurement of cellular solute flux and voltage; (2) an image with high resolution and contrast; (3) optical sectioning of the object at different levels; and (4) rapid recording of the morphological phenomena. This paper describes an example of commercially available apparatus meeting the above requirements, and illustrates its efficiency. The microscope is of the inverted type (Zeiss IM 35) equipped with differential-interference-contrast (DIC) with a long working distance, and an automatically controlled camera system. The microscopic image exhibits cellular and intercellular details in the unstained transporting mammalian nephron segments despite their tubular structure and great thickness and makes obvious function-structure correlations (e.g. cell volume changes); luminal and contraluminal cell borders are well resolved for controlled microelectrode impalement.

  19. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  20. Photogrammetry experiments with a model eye.

    Science.gov (United States)

    Rosenthal, A R; Falconer, D G; Pieper, I

    1980-01-01

    Digital photogrammetry was performed on stereophotographs of the optic nerve head of a modified Zeiss model eye in which optic cups of varying depths could be simulated. Experiments were undertaken to determine the impact of both photographic and ocular variables on the photogrammetric measurements of cup depth. The photogrammetric procedure tolerates refocusing, repositioning, and realignment as well as small variations in the geometric position of the camera. Progressive underestimation of cup depth was observed with increasing myopia, while progressive overestimation was noted with increasing hyperopia. High cylindrical errors at axis 90 degrees led to significant errors in cup depth estimates, while high cylindrical errors at axis 180 degrees did not materially affect the accuracy of the analysis. Finally, cup depths were seriously underestimated when the pupil diameter was less than 5.0 mm. Images PMID:7448139

  1. Digital Levelling in Subterranean Spaces

    Directory of Open Access Journals (Sweden)

    Tomáš Jiřikovský

    2007-06-01

    Full Text Available For precision levelling works are now more often used digital levels and code-scale staffs. Advantages in (and problems with their application to the regular line-levelling are well known and described. However, when using the digital levelling for measurements in specific local geodetic networks, monitoring networks and inside of buildings and underground spaces, new problems appear with the signalisation of the observed points, readability of the code (non-uniform illumination, temperature changes etc. The article informs about the application of two types of digital levels (Sokkia SDL-2, Trimble Zeiss DiNi 12T in the experimental subterranean levelling network for the basement settlement monitoring of a ten-floor building; the solution of marking of the points, field calibration and the system calibration of digital levels.

  2. Sample Preparation and Mounting of Drosophila Embryos for Multiview Light Sheet Microscopy.

    Science.gov (United States)

    Schmied, Christopher; Tomancak, Pavel

    2016-01-01

    Light sheet fluorescent microscopy (LSFM), and in particular its most widespread flavor Selective Plane Illumination Microscopy (SPIM), promises to provide unprecedented insights into developmental dynamics of entire living systems. By combining minimal photo-damage with high imaging speed and sample mounting tailored toward the needs of the specimen, it enables in toto imaging of embryogenesis with high spatial and temporal resolution. Drosophila embryos are particularly well suited for SPIM imaging because the volume of the embryo does not change from the single cell embryo to the hatching larva. SPIM microscopes can therefore image Drosophila embryos embedded in rigid media, such as agarose, from multiple angles every few minutes from the blastoderm stage until hatching. Here, we describe sample mounting strategies to achieve such a recording. We also provide detailed protocols to realize multiview, long-term, time-lapse recording of Drosophila embryos expressing fluorescent markers on the commercially available Zeiss Lightsheet Z.1 microscope and the OpenSPIM.

  3. Comportamiento de la cromósfera solar en la línea H-alpha durante el ciclo 23

    Science.gov (United States)

    Davoli, D.; Aquilano, R.; Missio, H.

    Using the instrumental of the Observatorio Astronómico Municipal de Rosario (OAMR), we analyze the solar chromospheric activity during an approximate period of 11 years. The instrument is a Carl Zeiss refractor telescope of 150 mm aperture and 2250 mm of focal distance with monochromatic filter in the H-alpha line. We take as proxy for the solar activity the area covered by chromospheric plages. Simultaneously, we determine the relative wolf number from observations of the solar photosphere. We describe our technique and the results obtained. We observe 2 maxima of solar activity in the years 2000 and 2001 respectively, and a later decrease of this activity with low average values starting around 2006 that corresponds to the end of cycle 23. FULL TEXT IN SPANISH

  4. Virtual microscopy: an evaluation of its validity and diagnostic performance in routine histologic diagnosis of skin tumors

    DEFF Research Database (Denmark)

    Nielsen, Patricia Switten; Lindebjerg, Jan; Rasmussen, Jan

    2010-01-01

    Digitization of histologic slides is associated with many advantages, and its use in routine diagnosis holds great promise. Nevertheless, few articles evaluate virtual microscopy in routine settings. This study is an evaluation of the validity and diagnostic performance of virtual microscopy...... in routine histologic diagnosis of skin tumors. Our aim is to investigate whether conventional microscopy of skin tumors can be replaced by virtual microscopy. Ninety-six skin tumors and skin-tumor-like changes were consecutively gathered over a 1-week period. Specimens were routinely processed, and digital...... slides were captured on Mirax Scan (Carl Zeiss MicroImaging, Göttingen, Germany). Four pathologists evaluated the 96 virtual slides and the associated 96 conventional slides twice with intermediate time intervals of at least 3 weeks. Virtual slides that caused difficulties were reevaluated to identify...

  5. Digital Archive of the Astrograph Plates Stored at the Inasan Zvenigorod Observatory

    Directory of Open Access Journals (Sweden)

    Vereshchagin S. V.

    2012-09-01

    Full Text Available The plate collection of the Zvenigorod 40-cm Carl Zeiss astrograph, obtained in 1972-2003, contains direct photographs of star fields, comets, asteroids, Pluto, and Mars. The electronic library of images from photographic plates was created from scanning the astronomical negatives. We present information on programs scheduled at the telescope and the structure and maintenance of the plate stacks. We also list the plates with images of asteroids and comets. Access to all our plate lists is provided at the web sites of the Institute of Astronomy (INASAN and WFPDB. It is possible to select plates by the date of observation, by the coordinates of the sky area, by the object type. Preview images can be inspected.

  6. Microstructure and Service Properties of Copper Alloys

    Directory of Open Access Journals (Sweden)

    Polok-Rubiniec M.

    2016-09-01

    Full Text Available This elaboration shows the effect of combined heat treatment and cold working on the structure and utility properties of alloyed copper. As the test material, alloyed copper CuTi4 was employed. The samples were subjected to treatment according to the following schema: 1st variant – supersaturation and ageing, 2nd variant – supersaturation, cold rolling and ageing. The paper presents the results of microstructure, hardness, and abrasion resistance. The analysis of the wipe profile geometry was realized using a Zeiss LSM 5 Exciter confocal microscope. Cold working of the supersaturated solid solution affects significantly its hardness but the cold plastic deformation causes deterioration of the wear resistance of the finally aged CuTi4 alloy.

  7. Oculometry findings in high myopia at adult age: considerations based on oculometric follow-up data over 28 years in a cohort-based Danish high-myopia series

    DEFF Research Database (Denmark)

    Fledelius, Hans C; Goldschmidt, Ernst

    2010-01-01

    PURPOSE: To present and discuss oculometry data in a series of adults with high myopia followed between the ages of 26 and 54 years. Emphasis is on axial length (AL) findings and corneal curvature radius (Crad). METHODS: Thirty-four out of the 39 individuals recruited as teenagers from a Copenhagen...... 1948 birth cohort with myopia of at least 6 D have had current follow-up exams, to include AL measurements (by ultrasound, 1974-2002; the latter year also with the Zeiss IOLMaster) and keratometry. The cross-sectional and longitudinal analyses are based primarily on the eyes with high myopia; however......, the fellow eye is also assessed in unilateral cases. RESULTS: At age 54 years, the maximum myopia in the series was -26 D; the highest AL value was 35.4 mm. The myopia had increased in most, with an increase from the 26-year oculometry baseline averaging 1.0 D [standard deviation (SD) 1.84]. Ultrasound...

  8. On the construction of a 2-metre mirror blank for the universal reflecting telescope in Tautenburg (German Title: Über die Fertigung eines 2-Meter-Spiegelträgers für das Universal-Spiegelteleskop in Tautenburg )

    Science.gov (United States)

    Lödel, Wolfgang

    The astronomers' desire to penetrate deeper into space transforms into a demand for larger telescopes. The primary mirror constitutes the main part of a reflecting telescope, and it determines all subsequent activities. Already in the 1930s activities existed in the Schott company to manufacture mirror blanks up to diameters of 2 metres, which could not be pursued because of political constraints. This ambitious goal was again picked up a few years after the war. At a time when the procurement of raw materials was extremely difficult, the glass workers of Schott in Jena attacked this large project. After some failures, a good mirror blank could be delivered to the Carl Zeiss Company in 1951 for further processing and for the construction of the first 2-metre reflecting telescope. From 1960 to 1986, this mirror made from optical glass ZK7 served its purpose at the Karl Schwarzschild Observatory in Tautenburg. lt was then replaced by a zero expansion glass ceramics mirror.

  9. [Regeneration of the ciliary beat of human ciliated cells].

    Science.gov (United States)

    Wolf, G; Koidl, B; Pelzmann, B

    1991-10-01

    The influence of an isotonic, alkaline saline solution (diluted "Emser Sole" or brine from the spa of Bad Ems) on the ciliary beat of isolated cultured human ciliated cells of the upper respiratory tract was investigated. The ciliary beat was observed via an inverted phase contrast microscope (Zeiss Axiomat IDPC) and measured microphotometrically under physiological conditions and after the damaging influence of 1% propanal solution. Under physiological conditions the saline solution had a positive, although statistically not significant influence on the frequency of the ciliary beat. After damage of the cultivated cells by 1% propanal solution, the saline solution had a significant better influence on the regeneration of the cultured cells than a physiological sodium chloride solution. It is concluded that diluted brine from Bad Ems has a positive effect on the ciliary beat of the respiratory epithelium and accelerates its regeneration after damage by viral and bacterial infections, surgery or inhaled noxae.

  10. Studying fatigue damage evolution in uni-directional composites using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    , it will be possible to lower the costs of energy for wind energy based electricity. In the present work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre failure during...... comparable x-ray studies) have been used in order to ensure a representative test volume during the ex-situ fatigue testing. Using the ability of the x-ray computed tomography to zoom into regions of interest, non-destructive, the fatigue damage evolution in a repeating ex-situ fatigue loaded test sample has...... improving the fatigue resistance of non-crimp fabric used in the wind turbine industry can be made....

  11. Revealing fatigue damage evolution in unidirectional composites for wind turbine blades using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    ’. Thereby, it will be possible to lower the cost of energy for wind energy based electricity. In the presented work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre...... to other comparable x-ray studies) have been used in order to ensure a representative test volume during the ex-situ fatigue testing. Using the ability of the x-ray computed tomography to zoom into regions of interest, non-destructive, the fatigue damage evolution in a repeating ex-situ fatigue loaded test...... improving the fatigue resistance of non-crimp fabric used in the wind turbine industry can be made....

  12. Seven year follow-up after advanced surface ablation with excimer laser for treatment of myopia: Long-term outcomes of cooling PRK and LASEK

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    Purpose: To evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA and CDVA), corneal haze, corneal densitometry and patient satisfaction up to 7 years after Photorefractive Keratectomy with cooling (cPRK) and Laser-Assisted Sub-epithelial Keratectomy...... (LASEK) for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark. Methods: Retrospective follow-up study of eyes treated with cPRK or LASEK for all degrees of myopia from 2007 to 2009 at the Department of Ophthalmology...... laser with eye-tracker (Carl Zeiss Meditec AG, Jena, Germany) was used for photoablation in both procedures. Optical zone size ranged from 5.50 to 6.00 mm in both procedures, and maximum attempted spherical correction was -8.50 D. cPRK was performed as a standard PRK procedure, but with immediately...

  13. [Morphometrical analyze of the middle cerebral artery system at the 13-15 weeks fetuses].

    Science.gov (United States)

    Macovei, Georgeta Nataşa; Varlam, H; St Antohe, D

    2002-01-01

    Tele-encephalization process is accompanied by the appearance and progressive complication of the middle cerebral artery system. The aim of our study is to analyze the morphometrical parameters of the middle cerebral artery branches in the beginning of the edification of its system. We used 162 cerebral hemispheres from 88 fetuses aged of 13-15 weeks. Middle cerebral artery system was injected with a gelatin-China ink mixture and images recorded by means of a Zeiss surgical microscope. Parameters evaluation (length, proximal and distal diameters, external surface, volume, angles of bifurcation) was realized with KS-300 program. At this early age middle cerebral artery system has only 4-5 generations of branches usually resulting from acute angle bifurcations.

  14. Automation of technological processes at surface mines in the GDR as one of the main directions of increased coal extraction effectiveness by surface mining

    Energy Technology Data Exchange (ETDEWEB)

    Jona, U.

    1987-12-01

    In the GDR, about 53% of brown coal is mined with the use of overburden conveyor bridges, 27% with the use of belt conveyors, and 20% with the use of rail transport. Compares efficiency and cost per 1 m/sup 3/ of these transport methods. The overburden conveyor bridges, their specifications and microcomputer control are described. Describes utilization of microcomputer techniques, especially the stereochart system of Carl Zeiss Jena, for automated processing of data on surface mine geometry. Other computer applications are also presented, e.g. for surveying, slope stability calculation, and conveyor bridge control. Maintains that application of the KED/KEM microcomputer system for overburden conveyor bridge control increases its effectiveness by 10%, i.e. by 8 million m/sup 3//a.

  15. Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

    Science.gov (United States)

    Wirtz, C R; Bonsanto, M M; Knauth, M; Tronnier, V M; Albert, F K; Staubert, A; Kunze, S

    1997-01-01

    We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

  16. Prize for Industrial Applications of Physics Talk: Low energy spread Ion source for focused ion beam systems-Search for the holy grail

    Science.gov (United States)

    Ward, Bill

    2011-03-01

    In this talk I will cover my personal experiences as a serial entrepreneur and founder of a succession of focused ion beam companies (1). Ion Beam Technology, which developed a 200kv (FIB) direct ion implanter (2). Micrion, where the FIB found a market in circuit edit and mask repair, which eventually merged with FEI corporation. and (3). ALIS Corporation which develop the Orion system, the first commercially successful sub-nanometer helium ion microscope, that was ultimately acquired by Carl Zeiss corporation. I will share this adventure beginning with my experiences in the early days of ion beam implantation and e-beam lithography which lead up to the final breakthrough understanding of the mechanisms that govern the successful creation and operation of a single atom ion source.

  17. Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

    DEFF Research Database (Denmark)

    Zheng, Yi; Yang, Yan; Rogowska, M.

    2017-01-01

    to achieve this is to find a suitable condition to create a stable 3D space in carbonate rock by injecting liquid to prepare space for the later CO2 injection. Micro-CT imaging is a non-destructive 3D method that can be used to study the property changes of carbonate rocks during and after CO2 injection....... The advance in lab source based micro-CT has made it capable of in situ experiments. We used a commercial bench top micro-CT (Zeiss Versa XRM410) to study the microstructure changes of chalk during liquid injection. Flexible temporal CT resolution is essential in this study because that the time scales...... of coupled physical and chemical processes can be very different. The results validated the feasibility of using a bench top CT system with a pressure cell to monitor the mesoscale multiphase interactions in chalk....

  18. Measuring large aspherics using a commercially available 3D-coordinate measuring machine

    Science.gov (United States)

    Otto, Wolfgang; Matthes, Axel; Schiehle, Heinz

    2000-07-01

    A CNC-controlled precision measuring machine is a very powerful tool in the optical shop not only to determine the surface figure, but also to qualify the radius of curvature and conic constant of aspherics. We used a commercially available 3D-coordinate measuring machine (CMM, ZEISS UPMC 850 CARAT S-ACC) to measure the shape of the GEMINI 1-m convex secondary mirrors at different lapping and polishing stages. To determine the measuring accuracy we compared the mechanical measurements with the results achieved by means of an interferometrical test setup. The data obtained in an early stage of polishing were evaluated in Zernike polynomials which show a very good agreement. The deviation concerning long wave rotational symmetrical errors was 20 nm rms, whereas the accuracy measuring of mid spatial frequency deviations was limited to about 100 nm rms.

  19. Contributions to the History of Astronomy, Vol. 7 (German Title: Beiträge zur Astronomiegeschichte, Band 7)

    Science.gov (United States)

    Dick, Wolfgang R.; Hamel, Jürgen

    The topics of this volume extend from the work of the islamic scienticst al-Tusi in the 13th century to the development of astronomical instrumentation at the Carl Zeiss Jena Company in the second half of the 20th century. The contents of the remaining articles are found between these limits: the well-known textbooks of Johannes de Sacrobosco, Tycho Brahe's stays in Augsburg, Gottfried Kirch's calendars, published around 1700, a portrait of Bessel, made during his Königsberg time, Fraunhofer's successors at the Munich Optical Institute, and Einstein's cosmological ideas in his ``Four lectures on the Theory of Relativity''. The earliest disputation of the learned Jesuit Christoph Scheiner is printed for the first time in a German translation. The volume is concluded by a bibliographical overview on historical Venus transits, additional short notes, an obituary of Jerzy Dobrzycki, and book reviews. Most papers are written in German. Main papers have English abstracts.

  20. Approach for investigations of progressive fatigue damage in 3D in fibre composites using X-ray tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard; Jespersen, Kristine Munk

    (Jespersen & Mikkelsen, 2016) has been performed. An ex-situ study where it has been important to design a good gripping strategy inside the scanning machine. Doing this, it has been possible to scan the same region multiple times. Thereby, a progressive fatigue damage evolution has been observed.......Understanding fatigue damage initiation and evolution in the load carrying laminates inside wind turbine blade plays a key factor designing longer and lighter turbine blades. Thereby, it is possible to lower the Cost of Energy for the wind energy based electricity production either by simply...... building larger wind turbines or by upgrading existing turbines for lower wind classes’ . In the presented work, a Zeiss Xradia Versa 520 scanner has been used in connection with ex-situ fatigue testing with the purpose of identifying fibre failure during the fatigue loading. The load carrying laminates...

  1. Investigation of the surface morphology of ion-bombarded biocompatible materials with a SEM and profilograph

    International Nuclear Information System (INIS)

    Kowalski, Z.W.

    1984-01-01

    The surface morphology (topography and roughness) is a very important factor which affects the response of biological tissue to an implant material. The effect of an incident ion beam on surface morphology of various biocompatible materials was studied. All materials were bombarded by Ar + ions at an applied voltage of 7 kV at various incident angles from 0 to 1.4 rad (0 to 80 deg) and at a beam current up to 0.1 mA. The surface topographies of ion-bombarded samples were examined with a Japan Electron Optics Laboratory, model JSM-35, scanning electron microscope. The roughness of the surface was calculated from the shape of a surface profile, which was recorded by a profilograph, the ME 10 (supplied by VEB Carl Zeiss, Jena). (author)

  2. Use of X-ray fluorescence analysis in studying vertical element migration in weathering zone

    International Nuclear Information System (INIS)

    Houdkova, Z.; Hally, J.

    1980-01-01

    The vertical migration of elements was studied in a model area of the Zelivka river basin. The VRS 2 Zeiss GDR analyzer, connected to automatic processor KSR 4 100, were used for the study of concentration variations. Soil samples were taken from bore holes drilled to a depth of the solid bedrock (0 to 6 m). The contents of SiO 2 , Al 2 O 3 , Fe 2 O 3 , K 2 O, CaO, TiO 2 , P 2 O 5 and MnO were determined in concentration ranges from 10 -2 to 10 1 %. The method was tested in comparative measurements against conventional methods of chemical analysis. (author)

  3. Compilation of 1990 Annual Reports of the Navy ELF Communications System Ecological Monitoring Program. Volume 3. Tabs G thru I.

    Science.gov (United States)

    1991-08-01

    crowned Kinglet 12 11 1 3 5 0 0 9 3 4 i Reciulus calendula _Gnatcatcher 0 1 0 0 0 0 00 0Blue-grayGattce Polioptila caerulea Eastern Bluebird 0 0 0 0 1 0 6 0...and species determinations was done at 1250X magnification on a Zeiss microscope equipped with phase contrast illumination and an oil immersion 10OX...xx MMN M M N NŘ N NMN NM M N II~ ~ 0 a MM NM 333 30661 6961 x x x 39961 x x xK x x S996 x K K U I *c E I I. i~~ 0* oil ] o o I4 33 0) x LL 5 I. CoI

  4. A Study of Precataclysmic Binaries Through Theoretic Modeling of Light Curves and Spectra

    Science.gov (United States)

    Mitrofanova, A. A.; Shimansky, V. V.; Borisov, N. V.

    2017-06-01

    The article presents results of three pre-cataclysmic binaries (PN G068.1+11.0, TW Crv and RE J2013+4002) investigation. Spectroscopic and photometric observations were obtained on BTA and Zeiss-1000 of SAO RAS and on RTT-150. We used the modeling of light curves and spectra to determine the fundamental parameters for all three systems. The PN G068.1+11.0 parameters were obtained with the use of the evolutionary tracks for the nuclei of planetary nebulae of different masses. According to the results of the study, it was found that the secondary components of PN G068.1+11.0 and TW Crv have luminosity excess, but secondary component of RE J2013+4002 doesn't have one.

  5. Comparasion of Optic Nerve Head with Stereophotometric and Scanning Laser Ophthalmoscopic Imaging

    Directory of Open Access Journals (Sweden)

    Serek Tekin

    2016-01-01

    Full Text Available Aim: To compare theevaluation results of two experienced clinicians about examination of optic discs in glaucoma patients and healthy inidividuals by stereophotometry and scanning laser ophthalmoscopy. Material and Method: We studied 116 individuals (217 eyes who were divided as normal, glaucoma and suspected glaucoma in numbers of 54, 42 and 20 respectively. Stereophotometric photographs of optic disc were examined with fundus camera (Zeiss, FF 450 plus. Optic disc was also evaluated with HRT-3 in the same visit. Two experienced clinicians evaluated the cup/disc ratios and whether the optic discs were glaucomatous or not. Evaluation results were analysed and compared with HRT-3 examinations. Results:There were no significant age and gende rdifferences between the groups(p>0.05.Stereophotographic C/D ratio correlations between the clinicians were 0.79 (p

  6. Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease.

    Science.gov (United States)

    Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea

    2015-12-01

    Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP). Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed. Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD. PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Utilizing Neon Ion Microscope for GaSb nanopatterning studies: Nanostructure formation and comparison with low energy nanopatterning

    International Nuclear Information System (INIS)

    El-Atwani, Osman; Huynh, Chuong; Norris, Scott

    2016-01-01

    Graphical abstract: - Highlights: • Carl Zeiss-neon ion microscope was used to irradiated GaSb surfaces with 5 keV neon. • In-situ imaging using helium beam and ex-situ imaging using an electron beam were performed. • Differences in imaging output between the helium and the electron beam were observed. • Transition occurred in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. • Collision cascade simulations suggested a transition toward bulk-driven mechanisms. - Abstract: Low energy irradiation of GaSb surfaces has been shown to lead to nanopillar formation. Being performed ex-situ, controlling the parameters of the ion beam for controlled nanopattern formation is challenging. While mainly utilized for imaging and cutting purposes, the development of multibeam (helium/neon) ion microscopes has opened the path towards the use of these microscopes for in-situ ion irradiation and nanopatterning studies. In this study, in-situ irradiation (neon ions)/imaging (helium ions) of GaSb surfaces is performed using Carl Zeiss-neon ion microscope at low energies (5 and 10 keV). Imaging with helium ions, nanodots were shown to form at particular fluences after which are smoothed. Ex-situ imaging with SEM showed nanopore formation of size controlled by the ion energy and fluence. Compared to lower energy ex-situ neon ion irradiation at similar fluxes, where nanopillars are formed, the results demonstrated a transition in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. Simulations show an increase in the ballistic diffusion and a decrease in the strength of phase separation as a function of ion energy in agreement with the suppression of nanopillar formation at higher energies. Collision cascade simulations suggest a transition toward bulk-driven mechanisms.

  8. [Comparison of film-screen combinations with contrast detail diagram and interactive image analysis. 2: Linear assessment of grey scale ranges with interactive image analysis].

    Science.gov (United States)

    Stamm, G; Eichbaum, G; Hagemann, G

    1997-09-01

    The following three screen-film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film, and c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum pre-filter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512 x 512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 microns2. Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated.

  9. Theaters of time and space: The American planetarium community, 1930-1970

    Science.gov (United States)

    Marche, Jordan Dale, II

    American astronomy education was transformed by the introduction of a remarkable teaching tool---the projection planetarium. Conceived at the Carl Zeiss firm of Jena, Germany, the first prototype was exhibited at the Deutsches Museum, Munich, in 1923. Between 1930 and 1970, more than 700 planetaria were completed or remained under construction in the Unite States, Canada, and Mexico. Members of the American planetarium community united to form the first continent-wide professional association and to launch its quarterly journal, signifying that disciplinary maturity had been achieved. Social developments in the American planetarium community are examined in light of three principal issues (along with the role of gender): patronage, professionalization, and popularization. The analytical narrative is supplemented by quantitative analysis of North American planetaria and their personnel. Utilizing methods employed in collective biography, the Appendix contains further assessments derived from five professional traits of the community's 919 known planetarium directors. On the basis of technological developments and the changing nature of patronage, three distinct periods of historical development are recognized. In the formative stage (1930--1946), the community was dominated by Zeiss-equipped facilities installed at five metropolitan cities. During the second period (1947--1957), inexpensive pinhole-style projectors, marketed by Philadelphia entrepreneur Armand N. Spitz, revolutionized the availability of 'artificial skies'. In response to the "crisis of confidence" triggered by Sputnik's launch, a third developmental period (1958--1970) ensued. The necessity of offering a space science education to rapidly growing numbers of young people justified the construction of hundreds of new planetaria through the 1960s. Originally created for teaching the confirmation of scientific theories, planetaria became important tools for researching other biological and educational

  10. Photographic Observations of Major Planets and Their Moons During 1961-1990 at the MAO NAS of Ukraine

    Science.gov (United States)

    Yizhakevych, O. M.; Andruk, V. M.; Pakuliak, L. K.

    We present the results of photographic observations' processing of Saturn's moons, Uranus, Neptune and their moons on the basis of MAO NAS of Ukraine photographic observational archive. The analysis of the results is given. Observations were obtained using 4 telescopes: Double Long-Focus Astrograph (DLFA, D/F = 400/5500), Zeiss Double Astrograph (DAZ, D/F= 400/3000), Reflector Zeiss-600 (D/F= 600/7500), Wideangle Astrograph, (DWA, D/F= 400/2000). Observations were carried out during 1961 - 1990 (http://gua.db.ukrvo. org). Digitizing of plates has been done by EPSON EXPRESSION 10000XL (EE) flatbed scanner in 16-bit gray color range with resolution 1200dpi.(Andruk et al.: 2005, 2012; Golovnja et al.: 2010;. Protsyuk et al. 2014a, 2014b). The reduction of plates was made using the software developed in MAO NASU in the enhanced LINUX-MIDAS software kit. (Andruk V. et al.: 2016a, 2016b). Tycho2 was used as a reference system. The internal accuracy of the reduction for the first three instruments is ±0.08 - ±0.13 arcsec for both coordinates. For the wide angle astrograph DWA, RMS errors appeared 2 - 2.5 times higher. The total amount of processed plates with images of Saturn's moons is 209 (511 frames), 33 plates contain the images of Uranus and U1,U2,U3,U4 moons, 29 plates have images of Neptune and N1 moon (Yizhakevych et al., 2015, 2016, 2017; Protsyuk et al., 2015). The online comparison of calculated positions of objects with IMCCE ephemeris data was made (http://lnfm1.sai.msu.ru/neb/nss/nssephmf.htm).

  11. Utilizing Neon Ion Microscope for GaSb nanopatterning studies: Nanostructure formation and comparison with low energy nanopatterning

    Energy Technology Data Exchange (ETDEWEB)

    El-Atwani, Osman, E-mail: oelatwan25@gmail.com [School of Nuclear Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Huynh, Chuong [Carl Zeiss Microscopy, LLC, One Corporation Way, Peabody, MA 01960 (United States); Norris, Scott [Department of Mathematics, Southern Methodist University, Dallas, TX 75275 (United States)

    2016-05-01

    Graphical abstract: - Highlights: • Carl Zeiss-neon ion microscope was used to irradiated GaSb surfaces with 5 keV neon. • In-situ imaging using helium beam and ex-situ imaging using an electron beam were performed. • Differences in imaging output between the helium and the electron beam were observed. • Transition occurred in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. • Collision cascade simulations suggested a transition toward bulk-driven mechanisms. - Abstract: Low energy irradiation of GaSb surfaces has been shown to lead to nanopillar formation. Being performed ex-situ, controlling the parameters of the ion beam for controlled nanopattern formation is challenging. While mainly utilized for imaging and cutting purposes, the development of multibeam (helium/neon) ion microscopes has opened the path towards the use of these microscopes for in-situ ion irradiation and nanopatterning studies. In this study, in-situ irradiation (neon ions)/imaging (helium ions) of GaSb surfaces is performed using Carl Zeiss-neon ion microscope at low energies (5 and 10 keV). Imaging with helium ions, nanodots were shown to form at particular fluences after which are smoothed. Ex-situ imaging with SEM showed nanopore formation of size controlled by the ion energy and fluence. Compared to lower energy ex-situ neon ion irradiation at similar fluxes, where nanopillars are formed, the results demonstrated a transition in the nanostructure type and formation mechanism as the energy is changed from 2 to 5 keV. Simulations show an increase in the ballistic diffusion and a decrease in the strength of phase separation as a function of ion energy in agreement with the suppression of nanopillar formation at higher energies. Collision cascade simulations suggest a transition toward bulk-driven mechanisms.

  12. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications.

    Science.gov (United States)

    Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen

    2016-02-01

    We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking

    Directory of Open Access Journals (Sweden)

    Natasha Pahuja

    2015-01-01

    Full Text Available Purpose. To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700 in keratoconus patients undergoing accelerated collagen crosslinking (ACXL between epithelium on (epi-on and epithelium off (epi-off. Methods. Intraoperative images were obtained during each of the procedures. Seven keratoconus patients underwent epi-on ACXL and four underwent epi-off ACXL. A software tool was developed using Microsoft.NET and Open Computer Vision (OpenCV libraries for image analysis. Pre- and postprocedure images were analyzed for changes in the corneal hyperreflectance pattern as a measure of the depth of riboflavin penetration. Results. The mean corneal hyperreflectance in the epi-on group was 12.97 ± 1.49 gray scale units (GSU before instillation of riboflavin and 14.46 ± 2.09 GSU after AXCL (P = 0.019 while in the epi-off group it was 11.43 ± 2.68 GSU and 16.98 ± 8.49 GSU, respectively (P = 0.002. The average depth of the band of hyperreflectance in the epi-on group was 149.39 ± 15.63 microns and in the epi-off group it was 191.04 ± 32.18 microns. Conclusion. This novel in vivo, real time imaging study demonstrates riboflavin penetration during epi-on and epi-off ACXL.

  14. Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis

    Science.gov (United States)

    Armstrong, James J.; Pintwala, Robert; Hutnik, Cindy

    2018-01-01

    Purpose Early detection, monitoring and understanding of changes in the retina are central to the diagnosis of glaucomatous optic neuropathy, and vital to reduce visual loss from this progressive condition. The main objective of this investigation was to compare glaucoma diagnostic accuracy of commercially available optical coherence tomography (OCT) devices (Zeiss Stratus, Zeiss Cirrus, Heidelberg Spectralis and Optovue RTVue, and Topcon 3D-OCT). Patients 16,104 glaucomatous and 11,543 normal eyes reported in 150 studies. Methods Between Jan. 2017 and Feb 2017, MEDLINE®, EMBASE®, CINAHL®, Cochrane Library®, Web of Science®, and BIOSIS® were searched for studies assessing glaucoma diagnostic accuracy of the aforementioned OCT devices. Meta-analysis was performed pooling area under the receiver operating characteristic curve (AUROC) estimates for all devices, stratified by OCT type (RNFL, macula), and area imaged. Results 150 studies with 16,104 glaucomatous and 11,543 normal control eyes were included. Key findings: AUROC of glaucoma diagnosis for RNFL average for all glaucoma patients was 0.897 (0.887–0.906, n = 16,782 patient eyes), for macula ganglion cell complex (GCC) was 0.885 (0.869–0.901, n = 4841 eyes), for macula ganglion cell inner plexiform layer (GCIPL) was 0.858 (0.835–0.880, n = 4211 eyes), and for total macular thickness was 0.795 (0.754–0.834, n = 1063 eyes). Conclusion The classification capability was similar across all 5 OCT devices. More diagnostically favorable AUROCs were demonstrated in patients with increased glaucoma severity. Diagnostic accuracy of RNFL and segmented macular regions (GCIPL, GCC) scans were similar and higher than total macular thickness. This study provides a synthesis of contemporary evidence with features of robust inclusion criteria and large sample size. These findings may provide guidance to clinicians when navigating this rapidly evolving diagnostic area characterized by numerous options. PMID:29300765

  15. The Role of the Modern Planetarium as an Effective Tool in Astronomy Education and Public Outreach

    Science.gov (United States)

    Albin, Edward F.

    2016-01-01

    As the planetarium approaches its 100th anniversary, today's planetarium educator must reflect on the role of such technology in contemporary astronomy education and outreach. The projection planetarium saw "first light" in 1923 at the Carl Zeiss factory in Jena, Germany. During the 20th century, the concept of a star projector beneath a dome flourished as an extraordinary device for the teaching of astronomy. The evolution of digital technology over the past twenty years has dramatically changed the perception / utilization of the planetarium. The vast majority of modern star theaters have shifted entirely to fulldome digital projection systems, abandoning the once ubiquitous electromechanical star projector altogether. These systems have evolved into ultra-high resolution theaters, capable of projecting imagery, videos, and any web-based media onto the dome. Such capability has rendered the planetarium as a multi-disciplinary tool, broadening its educational appeal to a wide variety of fields -- including life sciences, the humanities, and even entertainment venues. However, we suggest that what is at the heart of the planetarium appeal is having a theater adept at projecting a beautiful / accurate star-field. To this end, our facility chose to keep / maintain its aging Zeiss V star projector while adding fulldome digital capability. Such a hybrid approach provides an excellent compromise between presenting state of the art multimedia while at the same time maintaining the ability to render a stunning night sky. In addition, our facility maintains two portable StarLab planetariums for outreach purposes, one unit with a classic electromechanical star projector and the other having a relatively inexpensive fulldome projection system. With a combination of these technologies, it is possible for the planetarium to be an effective tool for astronomical education / outreach well into the 21st century.

  16. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening.

    Science.gov (United States)

    Rajalakshmi, Ramachandran; Arulmalar, Subramanian; Usha, Manoharan; Prathiba, Vijayaraghavan; Kareemuddin, Khaji Syed; Anjana, Ranjit Mohan; Mohan, Viswanathan

    2015-01-01

    To evaluate the sensitivity and specificity of "fundus on phone' (FOP) camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR) detection and DR severity in comparison with 7-standard field digital retinal photography. Single-site, prospective, comparative, instrument validation study. 301 patients (602 eyes) with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR) was defined by the presence of proliferative DR(PDR) or diabetic macular edema. The sensitivity, specificity and image quality were assessed. The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR) and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8-96.1) and 98.4% (95%CI 94.3-99.8) respectively and the kappa (ĸ) agreement was 0.90 (95%CI-0.85-0.95 p<0.001) while for STDR, the sensitivity was 87.9% (95%CI 83.2-92.9), specificity 94.9% (95%CI 89.7-98.2) and ĸ agreement was 0.80 (95%CI 0.71-0.89 p<0.001), compared to conventional photography. Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

  17. Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening.

    Directory of Open Access Journals (Sweden)

    Ramachandran Rajalakshmi

    Full Text Available To evaluate the sensitivity and specificity of "fundus on phone' (FOP camera, a smartphone based retinal imaging system, as a screening tool for diabetic retinopathy (DR detection and DR severity in comparison with 7-standard field digital retinal photography.Single-site, prospective, comparative, instrument validation study.301 patients (602 eyes with type 2 diabetes underwent standard seven-field digital fundus photography with both Carl Zeiss fundus camera and indigenous FOP at a tertiary care diabetes centre in South India. Grading of DR was performed by two independent retina specialists using modified Early Treatment of Diabetic Retinopathy Study grading system. Sight threatening DR (STDR was defined by the presence of proliferative DR(PDR or diabetic macular edema. The sensitivity, specificity and image quality were assessed.The mean age of the participants was 53.5 ±9.6 years and mean duration of diabetes 12.5±7.3 years. The Zeiss camera showed that 43.9% had non-proliferative DR(NPDR and 15.3% had PDR while the FOP camera showed that 40.2% had NPDR and 15.3% had PDR. The sensitivity and specificity for detecting any DR by FOP was 92.7% (95%CI 87.8-96.1 and 98.4% (95%CI 94.3-99.8 respectively and the kappa (ĸ agreement was 0.90 (95%CI-0.85-0.95 p<0.001 while for STDR, the sensitivity was 87.9% (95%CI 83.2-92.9, specificity 94.9% (95%CI 89.7-98.2 and ĸ agreement was 0.80 (95%CI 0.71-0.89 p<0.001, compared to conventional photography.Retinal photography using FOP camera is effective for screening and diagnosis of DR and STDR with high sensitivity and specificity and has substantial agreement with conventional retinal photography.

  18. Hydroxychloroquine Induced Retinopathy: A Case Series

    Directory of Open Access Journals (Sweden)

    Maryam Mobini

    2016-10-01

    Full Text Available Background and Purpose: Occular toxicity is one of the most important complications of Hydroxychloroquine. Not any type of treatment has so far been found and recommended for this disorder. The purpose of this study was to report some characteristics of patients with Hydroxychloroquine Induced Retinopathy.    Materials and Methods: From 107 patients with rheumatoid arthritis (RA and/or systemic lupus erythematosus (SLE during 2013-14 in Sari, Iran, who were selected by a simple sampling method and were referred to hospitals for ophthalmologic examinations, 21 patients were found with HCQ induced retinopathy. The Examination for HCQ-induced maculopathy was performed through fundoscopy, perimetry or optical coherence tomography (OCT, and the physicians had their own discretion based on the examination. Although the patients were examined by different ophthalmologists, all of them were evaluated by the same device (Zeiss cirrus HD OCT4000.USA for OCT, Zeiss Humphrey Field analyzer 2i. USA for visual field, and Topcon. TRC.50Dx. Japan for angiography. Based on the collected data, the characteristics of clinical and ophthalmologic changes were reported, and the data were analysed through Independent Sample t Test and χ2.    Results: 21 patients (19 females with a mean age of 49.86 (±15.6 were evaluated during 4.95 (±4.7 years of therapy. The mean of cumulative dose was calculated to be 313.18±269.8 grams. Based on the findings, hypertension was detected in 5 (23.8% of the patients. Conclusion: In the present study, it was found that HCQ induced retinal toxicity may occur even in recommended doses or for less than 5 years. Other risk factors such as hypertension in addition to the dose or duration of toxicity could also accelerate retinal toxicity.

  19. Morfometria do tecido conjuntivo do coração de equinos PSI

    Directory of Open Access Journals (Sweden)

    Eduardo Pecorali Leite

    2004-06-01

    Full Text Available Objetivou-se, neste trabalho, estudar a proporção de tecido conjuntivo existente na fração ventricular direita e esquerda do músculo cardíaco de eqüinos da raça puro sangue inglês, buscando, através da morfometria, dados referentes à inter-relação entre o tecido conjuntivo e o tecido muscular cardíaco. Utilizaram-se corações eqüinos, machos, com idade entre 20 e 120 meses, sem alterações cardíacas. Preparou-se o material oriundo da região média do terço médio dos ventrículos, tanto da face direita quanto da esquerda, segundo as técnicas histológicas convencionais e corados com Picrosirius red, Fucsina-Paraldeido associada ao Tricromo de Gomori e Tricromo de Masson, para evidenciação das fibras conjuntivas. As lâminas foram analisadas com auxílio do Axioscópio Zeiss® acoplado ao programa de análise de imagens KS-400 Zeiss. A quantidade de tecido conjuntivo no Ventrículo Esquerdo variou de 0,008 a 24,695%; no Ventrículo Direito variou de 0,029 a 20,921%; nos corações de eqüinos da raça puro sangue inglês. Os resultados obtidos mostram que há uma complexa rede de fibras conjuntivas envolvendo as fibras do tecido muscular cardíaco e que sua quantidade e disposição é muito variada, dependendo da região estudada, animais mais jovens exibem baixa quantidade de tecido conjuntivo, também dependendo de sua atividade física.

  20. Comparison of screen-film combinations: results of a contrast detail study and interactive image quality analysis. Pt. 2. Linear assessment of grey scale ranges with interactive (automatic) image analysis

    International Nuclear Information System (INIS)

    Stamm, G.; Eichbaum, G.; Hagemann, G.

    1997-01-01

    The following three screen-film combinations were compared: (a) A combination of anticross-over film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film, and (c) a conventional green fluorescing screen-film combination. Radiographs of a specially designed plexiglass phantom (0.2x0.2x0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminium prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an IBAS system and a Zeiss Kontron computer. Display conditions were the following: Display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a Pb0 photocathode, 625 lines (Siemens Heimann), an IBAS image matrix of 512x512 pixels with a resolution of 7 lines/mm, the projected matrix area was 5000 μm 2 . Grey scale ranges were measured on a line perpendicular to the grouped bar patterns. The difference between the maximum and minimum density value served as signal. The spatial resolution of the detector system was measured when the signal value was three times higher than the standard deviation of the means of multiple density measurements. The results showed considerable advantages of the two new screen-film combinations as compared to the conventional screen-film combination. The result was contradictory to the findings with pure visual assessment of thresholds (part I) that had found no differences. The authors concluded that (automatic) interactive image analysis algorithms serve as an objective measure and are specifically advantageous when small differences in image quality are to be evaluated. (orig.) [de

  1. Using Donor Lenticules Obtained Through SMILE for an Epikeratophakia Technique Combined With Phototherapeutic Keratectomy.

    Science.gov (United States)

    Zhao, Jing; Sun, Ling; Shen, Yang; Tian, Mi; Yao, Peijun; Zhou, Xingtao

    2016-12-01

    To investigate the feasibility, safety, and efficacy of using a donor lenticule created during small incision lenticule extraction (SMILE) in an epikeratophakia technique combined with phototherapeutic keratectomy (PTK). Six patients with decreased visual acuity due to a recurrence of corneal dystrophy were included in this prospective pilot study. PTK was performed using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany) followed by the transplantation of donor lenticules onto the recipient eyes. These lenticules were extracted during SMILE procedures using the VisuMax femtosecond laser (Carl Zeiss Meditec) on 6 donors with myopia and served as the epikeratophakia tissue. The surgeries and postoperative follow-up examinations were uneventful and no complications were noted over 6 months of follow-up. The epithelium remodelling was achieved within 1 month. At the last measurement, the corrected distance visual acuity of all recipient eyes gained at least two lines. Five eyes (83.3%) gained at least two lines of uncorrected distance visual acuity compared to their preoperative levels. Mean keratometric power increased by 5.97 ± 3.73 diopters and central corneal thickness increased by 55.25 ± 36.38 µm. The epithelium healed and the lenticules remained clear over the follow-up period as observed under slit-lamp examination. Anterior segment optical coherence tomography observation showed the lenticule was transparent with a visible demarcation line during the follow-up examination. The use of a SMILE lenticule as a donor lenticule for an epikeratophakia technique appears feasible and safe in the short term. The predictability and long-term effects need further investigation. [J Refract Surg. 2016;32(12):840-845.]. Copyright 2016, SLACK Incorporated.

  2. The efficiency of aspheric intraocular lens according to biometric measurements.

    Science.gov (United States)

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  3. Efeitos da hiperprolactinemia sobre o útero de camundongos no proestro Hyperprolactinemia effects on the female mice uterus during proestrous

    Directory of Open Access Journals (Sweden)

    Regina Célia Teixeira Gomes

    2009-08-01

    Full Text Available OBJETIVO: avaliar o efeito da hiperprolactinemia induzida pela metoclopramida sobre o endométrio e miométrio de camundongos fêmeas na fase de proestro. MÉTODOS: 24 camundongos fêmeas foram divididas aleatoriamente em dois grupos: GCtr/controle e GExp/tratadas com metoclopramida (6,7 µg/g por dia. Após 50 dias, os animais foram sacrificados na fase de proestro, e o sangue foi coletado para determinação dos níveis de estradiol, progesterona e prolactina. Os cornos uterinos foram removidos e fixados em formol a 10%; foram, então, processados para inclusão em parafina. Cortes de 4 µm foram corados pela hematoxilina-eosina (H/E. Na análise morfológica, foi utilizado microscópio de luz, da marca Carl Zeiss, com objetivas variando de 4 a 400 X, para caracterização de cada corte histológico. Na análise morfométrica, foi avaliada a espessura do epitélio superficial, da lâmina própria e do miométrio, com auxílio de um analisador de imagem (AxionVision, Carl Zeiss acoplado ao microscópio de luz (Carl Zeiss. A análise estatística foi realizada pela ANOVA seguida pelo teste Wilcoxon. O valor de p foi considerado significante quando PURPOSE: to evaluate the effect of hyperprolactinemia induced by metoclopramide on the endometrium and myometrium of female mice in the proestrus phase. METHODS: 24 female mice were randomly divided in two groups: CtrG/control and ExpG/treated with metoclopramide (6.7 mg/g daily. After 50 days, the animals were sacrificed in the proestrus phase, and the blood was collected to determine the levels of estradiol, progesterone and prolactin. The uterine horns were removed, fixed in 10% formaldehyde and processed before being included in paraffin. Slices of 4 µm were stained by hematoxylin and eosin (H/E. In the morphological analysis, a Carl Zeiss light microscope, with objectives varying from 4 to 400 X was used for each histological slice characterization. In the morphometrical analysis, the superficial

  4. Application of gyrotheodolite for alignment in large spacecraft installation process%陀螺经纬仪在大型航天产品精测中的应用

    Institute of Scientific and Technical Information of China (English)

    任春珍; 季宇; 孙刚

    2011-01-01

    The gyrotheodolite is a kind of orientation instrument commonly used for determining the azimuth angle relative to the local North. In the AIT process of Tiangong-Ⅰ target spacecraft, it is required to determine the attitude of two devices at operation platforms of different heights. On that condition, two theodolites may be blocked due to alignment between each other, thus it is unable to set up the relationship between the datum cube mirrors. To solve that problem, the geodetic coordinates are used as a transfer coordinate system to obtain the angle relationships. This new method for gyrotheodolite measurement is shown to be feasible with a satisfactory error analysis result, which can be used for similar precision measurements of large spacecraft.%陀螺经纬仪通常是做某一方向与当地大地北向的方位角关系测量用.文章针对“天宫一号”目标飞行器精测中遇到的问题,即高空不同平台间两台设备需要姿态关系测量的需求,通过对陀螺经纬仪测量原理的研究,借助大地坐标系作为中间传递坐标系,解决了经纬仪测量因互瞄被遮挡无法建立基准镜坐标系间关系的问题.测量误差分析结果验证了这种新方法的可行性,该方法可用于大型航天产品设备安装精度的测量.

  5. The Orientations of the Giza Pyramids and Associated Structures

    Science.gov (United States)

    Nell, Erin; Ruggles, Clive

    2014-08-01

    Ever since Flinders Petrie undertook a theodolite survey on the Giza plateau in 1881 and drew attention to the extraordinary degree of precision with which the three colossal pyramids are oriented upon the four cardinal directions, there have been a great many suggestions as to how this was achieved and why it was of importance. Surprisingly, given the many astronomical hypotheses and speculations that have been offered in the intervening 130 years, there have been remarkably few attempts to reaffirm or improve on the basic survey data concerning the primary orientations. This paper presents the results of a week-long Total Station survey undertaken by the authors during December 2006 whose principal aim was to clarify the basic data concerning the orientation of each side of the three large pyramids and to determine, as accurately as possible, the orientations of as many as possible of the associated structures. The principal difference between this and all previous surveys is that it focuses upon measurements of sequences of points along multiple straight and relatively well preserved structural segments, with best-fit techniques being used to provide the best estimate of their orientation, as opposed to simple triangulation between directly identified or extrapolated corners. Our results suggest that there is only a very slight difference in orientation (c. 0.5 arc minutes) between the north-south axes of Khufu's and Khafre's pyramids, that the sides of Khafre's are more perfectly perpendicular than those of Khufu's, and that the east-west axis is closer to true cardinality in both cases. The broader context of associated structures suggests that the east-west orientation in relation to sunrise or (in one case) sunset may have been a, or even the, key factor in many cases.

  6. The Photogrammetry Cube

    Science.gov (United States)

    2008-01-01

    We can determine distances between objects and points of interest in 3-D space to a useful degree of accuracy from a set of camera images by using multiple camera views and reference targets in the camera s field of view (FOV). The core of the software processing is based on the previously developed foreign-object debris vision trajectory software (see KSC Research and Technology 2004 Annual Report, pp. 2 5). The current version of this photogrammetry software includes the ability to calculate distances between any specified point pairs, the ability to process any number of reference targets and any number of camera images, user-friendly editing features, including zoom in/out, translate, and load/unload, routines to help mark reference points with a Find function, while comparing them with the reference point database file, and a comprehensive output report in HTML format. In this system, scene reference targets are replaced by a photogrammetry cube whose exterior surface contains multiple predetermined precision 2-D targets. Precise measurement of the cube s 2-D targets during the fabrication phase eliminates the need for measuring 3-D coordinates of reference target positions in the camera's FOV, using for example a survey theodolite or a Faroarm. Placing the 2-D targets on the cube s surface required the development of precise machining methods. In response, 2-D targets were embedded into the surface of the cube and then painted black for high contrast. A 12-inch collapsible cube was developed for room-size scenes. A 3-inch, solid, stainless-steel photogrammetry cube was also fabricated for photogrammetry analysis of small objects.

  7. Imaging Total Stations - Modular and Integrated Concepts

    Science.gov (United States)

    Hauth, Stefan; Schlüter, Martin

    2010-05-01

    Keywords: 3D-Metrology, Engineering Geodesy, Digital Image Processing Initialized in 2009, the Institute for Spatial Information and Surveying Technology i3mainz, Mainz University of Applied Sciences, forces research towards modular concepts for imaging total stations. On the one hand, this research is driven by the successful setup of high precision imaging motor theodolites in the near past, on the other hand it is pushed by the actual introduction of integrated imaging total stations to the positioning market by the manufacturers Topcon and Trimble. Modular concepts for imaging total stations are manufacturer independent to a large extent and consist of a particular combination of accessory hardware, software and algorithmic procedures. The hardware part consists mainly of an interchangeable eyepiece adapter offering opportunities for digital imaging and motorized focus control. An easy assembly and disassembly in the field is possible allowing the user to switch between the classical and the imaging use of a robotic total station. The software part primarily has to ensure hardware control, but several level of algorithmic support might be added and have to be distinguished. Algorithmic procedures allow to reach several levels of calibration concerning the geometry of the external digital camera and the total station. We deliver insight in our recent developments and quality characteristics. Both the modular and the integrated approach seem to have its individual strengths and weaknesses. Therefore we expect that both approaches might point at different target applications. Our aim is a better understanding of appropriate applications for robotic imaging total stations. First results are presented. Stefan Hauth, Martin Schlüter i3mainz - Institut für Raumbezogene Informations- und Messtechnik FH Mainz University of Applied Sciences Lucy-Hillebrand-Straße 2, 55128 Mainz, Germany

  8. Optics of Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII): Delay Lines and Alignment

    Science.gov (United States)

    Dhabal, Arnab; Rinehart, Stephen A.; Rizzo, Maxime J.; Mundy, Lee; Fixsen, Dale; Sampler, Henry; Mentzell, Eric; Veach, Todd; Silverberg, Robert F.; Furst, Stephen; hide

    2016-01-01

    We present the optics of Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII) as it gets ready for launch. BETTII is an 8-meter baseline far-infrared (30-90 microns) interferometer mission with capabilities of spatially resolved spectroscopy aimed at studying star formation and galaxy evolution. The instrument collects light from its two arms, makes them interfere, divides them into two science channels (30-50 microns and 60-90 microns), and focuses them onto the detectors. It also separates out the NIR light (1-2.5 microns) and uses it for tip-tilt corrections of the telescope pointing. Currently, all the optical elements have been fabricated, heat treated, coated appropriately and are mounted on their respective assemblies. We are presenting the optical design challenges for such a balloon borne spatio-spectral interferometer, and discuss how they have been mitigated. The warm and cold delay lines are an important part of this optics train. The warm delay line corrects for path length differences between the left and the right arm due to balloon pendulation, while the cold delay line is aimed at introducing a systematic path length difference, thereby generating our interferograms from where we can derive information about the spectra. The details of their design and the results of the testing of these opto-mechanical parts are also discussed. The sensitivities of different optical elements on the interferograms produced have been determined with the help of simulations using FRED software package. Accordingly, an alignment plan is drawn up which makes use of a laser tracker, a CMM, theodolites and a LUPI interferometer.

  9. NASA Tech Briefs, January 2003

    Science.gov (United States)

    2003-01-01

    Topics covered include: Optoelectronic Tool Adds Scale Marks to Photographic Images; Compact Interconnection Networks Based on Quantum Dots; Laterally Coupled Quantum-Dot Distributed-Feedback Lasers; Bit-Serial Adder Based on Quantum Dots; Stabilized Fiber-Optic Distribution of Reference Frequency; Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System; Ladar System Identifies Obstacles Partly Hidden by Grass; Survivable Failure Data Recorders for Spacecraft; Fiber-Optic Ammonia Sensors; Silicon Membrane Mirrors with Electrostatic Shape Actuators; Nanoscale Hot-Wire Probes for Boundary-Layer Flows; Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing; Efficient Coupling of Lasers to Telescopes with Obscuration; Aligning Three Off-Axis Mirrors with Help of a DOE; Calibrating Laser Gas Measurements by Use of Natural CO2; Laser Ranging Simulation Program; Micro-Ball-Lens Optical Switch Driven by SMA Actuator; Evaluation of Charge Storage and Decay in Spacecraft Insulators; Alkaline Capacitors Based on Nitride Nanoparticles; Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells; Software for a GPS-Reflection Remote-Sensing System; Software for Building Models of 3D Objects via the Internet; "Virtual Cockpit Window" for a Windowless Aerospacecraft; CLARAty Functional-Layer Software; Java Library for Input and Output of Image Data and Metadata; Software for Estimating Costs of Testing Rocket Engines; Energy-Absorbing, Lightweight Wheels; Viscoelastic Vibration Dampers for Turbomachine Blades; Soft Landing of Spacecraft on Energy-Absorbing Self-Deployable Cushions; Pneumatically Actuated Miniature Peristaltic Vacuum Pumps; Miniature Gas-Turbine Power Generator; Pressure-Sensor Assembly Technique; Wafer-Level Membrane-Transfer Process for Fabricating MEMS; A Reactive-Ion Etch for Patterning Piezoelectric Thin Film; Wavelet-Based Real-Time Diagnosis of Complex Systems; Quantum Search in Hilbert Space; Analytic Method for Computing Instrument

  10. Parallels Between Antarctic Travel in 1950 and Planetary Travel in 2050 (to Accompany Notes on "The Norwegian British-Swedish Antarctic Expedition 1949-52")

    Science.gov (United States)

    Swithinbank, Charles

    2012-01-01

    Objectives (Slides 2, 12, 21-22) To explore as much as possible of 1 million km2 of unexplored territory. We were the first expedition to winter in Antarctica between 95 E and 57 W - nearly half the coastline of Antarctica. It was understood that we must be self-sufficient in every respect for 2 years. There could be no firm or detailed plans for inland exploration until we found where it was possible to make a landing. Geology (Slide 20) Our two geologists traveled far from the Advance Base during both field seasons. Carrying fuel supplies (dog food) for a month, man food (dehydrated) and rock specimens acquired along the way, they covered a vast area. The surveyor drove his own dogs with the geophysicist as assistant. While the geologists were hacking away at rocks, the survey team lugged a theodolite up peaks to extend a triangulation network. Glaciology (Slides 21-22) The glaciologists each had an assistant from the support staff, so they could either travel together or divided into two parties to cover more ground. At each camp they dug a pit to determine the rate of snow accumulation, drilled (by hand) to a depth of 10 m to measure ice temperatures, and in places set up and surveyed ice-movement markers to be resurveyed the following season. Geophysics (Slides 33, 34-36, 38) The principal object was to determine the thickness of ice by seismic sounding the only means known at the time. After experiments as far as the Advance Base in the 1950-51 summer, both Weasels were devoted to a seismic sounding traverse in 1951-52 as far inland as supplies would allow. The party reached 620 km inland and found ice thicknesses of 2,500 m.

  11. Global Positioning System (GPS) survey of Augustine Volcano, Alaska, August 3-8, 2000: data processing, geodetic coordinates and comparison with prior geodetic surveys

    Science.gov (United States)

    Pauk, Benjamin A.; Power, John A.; Lisowski, Mike; Dzurisin, Daniel; Iwatsubo, Eugene Y.; Melbourne, Tim

    2001-01-01

    Between August 3 and 8,2000,the Alaska Volcano Observatory completed a Global Positioning System (GPS) survey at Augustine Volcano, Alaska. Augustine is a frequently active calcalkaline volcano located in the lower portion of Cook Inlet (fig. 1), with reported eruptions in 1812, 1882, 1909?, 1935, 1964, 1976, and 1986 (Miller et al., 1998). Geodetic measurements using electronic and optical surveying techniques (EDM and theodolite) were begun at Augustine Volcano in 1986. In 1988 and 1989, an island-wide trilateration network comprising 19 benchmarks was completed and measured in its entirety (Power and Iwatsubo, 1998). Partial GPS surveys of the Augustine Island geodetic network were completed in 1992 and 1995; however, neither of these surveys included all marks on the island.Additional GPS measurements of benchmarks A5 and A15 (fig. 2) were made during the summers of 1992, 1993, 1994, and 1996. The goals of the 2000 GPS survey were to:1) re-measure all existing benchmarks on Augustine Island using a homogeneous set of GPS equipment operated in a consistent manner, 2) add measurements at benchmarks on the western shore of Cook Inlet at distances of 15 to 25 km, 3) add measurements at an existing benchmark (BURR) on Augustine Island that was not previously surveyed, and 4) add additional marks in areas of the island thought to be actively deforming. The entire survey resulted in collection of GPS data at a total of 24 sites (fig. 1 and 2). In this report we describe the methods of GPS data collection and processing used at Augustine during the 2000 survey. We use this data to calculate coordinates and elevations for all 24 sites surveyed. Data from the 2000 survey is then compared toelectronic and optical measurements made in 1988 and 1989. This report also contains a general description of all marks surveyed in 2000 and photographs of all new marks established during the 2000 survey (Appendix A).

  12. Development and performance validation of a cryogenic linear stage for SPICA-SAFARI verification

    Science.gov (United States)

    Ferrari, Lorenza; Smit, H. P.; Eggens, M.; Keizer, G.; de Jonge, A. W.; Detrain, A.; de Jonge, C.; Laauwen, W. M.; Dieleman, P.

    2014-07-01

    In the context of the SAFARI instrument (SpicA FAR-infrared Instrument) SRON is developing a test environment to verify the SAFARI performance. The characterization of the detector focal plane will be performed with a backilluminated pinhole over a reimaged SAFARI focal plane by an XYZ scanning mechanism that consists of three linear stages stacked together. In order to reduce background radiation that can couple into the high sensitivity cryogenic detectors (goal NEP of 2•10-19 W/√Hz and saturation power of few femtoWatts) the scanner is mounted inside the cryostat in the 4K environment. The required readout accuracy is 3 μm and reproducibility of 1 μm along the total travel of 32 mm. The stage will be operated in "on the fly" mode to prevent vibrations of the scanner mechanism and will move with a constant speed varying from 60 μm/s to 400 μm/s. In order to meet the requirements of large stroke, low dissipation (low friction) and high accuracy a DC motor plus spindle stage solution has been chosen. In this paper we will present the stage design and stage characterization, describing also the measurements setup. The room temperature performance has been measured with a 3D measuring machine cross calibrated with a laser interferometer and a 2-axis tilt sensor. The low temperature verification has been performed in a wet 4K cryostat using a laser interferometer for measuring the linear displacements and a theodolite for measuring the angular displacements. The angular displacements can be calibrated with a precision of 4 arcsec and the position could be determined with high accuracy. The presence of friction caused higher values of torque than predicted and consequently higher dissipation. The thermal model of the stage has also been verified at 4K.

  13. UST-ID robotics: Wireless communication and minimum conductor technology, and end-point tracking technology surveys

    International Nuclear Information System (INIS)

    Holliday, M.A.

    1993-10-01

    This report is a technology review of the current state-of-the-art in two technologies applicable to the Underground Storage Tank (UST) program at the Hanford Nuclear Reservation. The first review is of wireless and minimal conductor technologies for in-tank communications. The second review is of advanced concepts for independent tool-point tracking. This study addresses the need to provide wireless transmission media or minimum conductor technology for in-tank communications and robot control. At present, signals are conducted via contacting transmission media, i.e., cables. Replacing wires with radio frequencies or invisible light are commonplace in the communication industry. This technology will be evaluated for its applicability to the needs of robotics. Some of these options are radio signals, leaky coax, infrared, microwave, and optical fiber systems. Although optical fiber systems are contacting transmission media, they will be considered because of their ability to reduce the number of conductors. In this report we will identify, evaluate, and recommend the requirements for wireless and minimum conductor technology to replace the present cable system. The second section is a technology survey of concepts for independent end-point tracking (tracking the position of robot end effectors). The position of the end effector in current industrial robots is determined by computing that position from joint information, which is basically a problem of locating a point in three-dimensional space. Several approaches are presently being used in industrial robotics, including: stereo-triangulation with a theodolite network and electrocamera system, photogrammetry, and multiple-length measurement with laser interferometry and wires. The techniques that will be evaluated in this survey are advanced applications of the aforementioned approaches. These include laser tracking (3-D and 5-D), ultrasonic tracking, vision-guided servoing, and adaptive robotic visual tracking

  14. Two-UAV Intersection Localization System Based on the Airborne Optoelectronic Platform.

    Science.gov (United States)

    Bai, Guanbing; Liu, Jinghong; Song, Yueming; Zuo, Yujia

    2017-01-06

    To address the limitation of the existing UAV (unmanned aerial vehicles) photoelectric localization method used for moving objects, this paper proposes an improved two-UAV intersection localization system based on airborne optoelectronic platforms by using the crossed-angle localization method of photoelectric theodolites for reference. This paper introduces the makeup and operating principle of intersection localization system, creates auxiliary coordinate systems, transforms the LOS (line of sight, from the UAV to the target) vectors into homogeneous coordinates, and establishes a two-UAV intersection localization model. In this paper, the influence of the positional relationship between UAVs and the target on localization accuracy has been studied in detail to obtain an ideal measuring position and the optimal localization position where the optimal intersection angle is 72.6318°. The result shows that, given the optimal position, the localization root mean square error (RMS) will be 25.0235 m when the target is 5 km away from UAV baselines. Finally, the influence of modified adaptive Kalman filtering on localization results is analyzed, and an appropriate filtering model is established to reduce the localization RMS error to 15.7983 m. Finally, An outfield experiment was carried out and obtained the optimal results: σ B = 1.63 × 10 - 4 ( ° ) , σ L = 1.35 × 10 - 4 ( ° ) , σ H = 15.8 ( m ) , σ s u m = 27.6 ( m ) , where σ B represents the longitude error, σ L represents the latitude error, σ H represents the altitude error, and σ s u m represents the error radius.

  15. Ash and Steam, Soufriere Hills Volcano, Monserrat

    Science.gov (United States)

    2002-01-01

    International Space Station crew members are regularly alerted to dynamic events on the Earth's surface. On request from scientists on the ground, the ISS crew observed and recorded activity from the summit of Soufriere Hills on March 20, 2002. These two images provide a context view of the island (bottom) and a detailed view of the summit plume (top). When the images were taken, the eastern side of the summit region experienced continued lava growth, and reports posted on the Smithsonian Institution's Weekly Volcanic Activity Report indicate that 'large (50-70 m high), fast-growing, spines developed on the dome's summit. These spines periodically collapsed, producing pyroclastic flows down the volcano's east flank that sometimes reached the Tar River fan. Small ash clouds produced from these events reached roughly 1 km above the volcano and drifted westward over Plymouth and Richmond Hill. Ash predominately fell into the sea. Sulfur dioxide emission rates remained high. Theodolite measurements of the dome taken on March 20 yielded a dome height of 1,039 m.' Other photographs by astronauts of Montserrat have been posted on the Earth Observatory: digital photograph number ISS002-E-9309, taken on July 9, 2001; and a recolored and reprojected version of the same image. Digital photograph numbers ISS004-E-8972 and 8973 were taken 20 March, 2002 from Space Station Alpha and were provided by the Earth Sciences and Image Analysis Laboratory at Johnson Space Center. Additional images taken by astronauts and cosmonauts can be viewed at the NASA-JSC Gateway to Astronaut Photography of Earth.

  16. Laser Tracker Calibration - Testing the Angle Measurement System -

    Energy Technology Data Exchange (ETDEWEB)

    Gassner, Georg; Ruland, Robert; /SLAC

    2008-12-05

    Physics experiments at the SLAC National Accelerator Laboratory (SLAC) usually require high accuracy positioning, e. g. 100 {micro}m over a distance of 150 m or 25 {micro}m in a 10 x 10 x 3 meter volume. Laser tracker measurement systems have become one of the most important tools for achieving these accuracies when mapping components. The accuracy of these measurements is related to the manufacturing tolerances of various individual components, the resolutions of measurement systems, the overall precision of the assembly, and how well imperfections can be modeled. As with theodolites and total stations, one can remove the effects of most assembly and calibration errors by measuring targets in both direct and reverse positions and computing the mean to obtain the result. However, this approach does not compensate for errors originating from the encoder system. In order to improve and gain a better understanding of laser tracker angle measurement tolerances we extended our laboratory's capabilities with the addition of a horizontal angle calibration test stand. This setup is based on the use of a high precision rotary table providing an angular accuracy of better than 0.2 arcsec. Presently, our setup permits only tests of the horizontal angle measurement system. A test stand for vertical angle calibration is under construction. Distance measurements (LECOCQ & FUSS, 2000) are compared to an interferometer bench for distances of up to 32 m. Together both tests provide a better understanding of the instrument and how it should be operated. The observations also provide a reasonable estimate of covariance information of the measurements according to their actual performance for network adjustments.

  17. Light and enlightenment: some musings

    Science.gov (United States)

    Patthoff, Donald D.

    2012-03-01

    In the beginning of the age of enlightenment (or reason), the language of philosophy, science, and theology stemmed equally from the same pens. Many of these early enlightenment authors also applied their thoughts and experiences to practical inventions and entrepreneurship; in the process, they noted and measured different characteristics of light and redirected the use of lenses beyond that of the heat lens which had been developing for over 2000 years. Within decades, microscopes, telescopes, theodolites, and many variations of the heat lens were well known. These advances rapidly changed and expanded the nature of science, subsequent technology, and many boundary notions; that is the way boundaries are defined not just in the sense of what is land and commercial property, but also what notions of boundary help shape and define society, including the unique role that professions play within society. The advent of lasers in the mid twenty century, though, introduced the ability to measure the effects and characteristic of single coherent wavelengths. This also introduced more ways to evaluate the relationship of specific wavelengths of light to other variables and interactions. At the most basic level, the almost revolutionary boundary developments of lasers seem to split down two paths of work: 1) a pursuit of more sophisticated heat lenses having better controls over light's destructive and cutting powers and, 2) more nuanced light-based instruments that not only enhanced the powers of observation, but also offered more minute measurement opportunities and subtle treatment capabilities. It is well worth deliberating, then, if "enlightenment" and "light" might share more than five letters in a row. And (if a common underlying foundation is revealed within these deliberations) , is it worth questioning any possible revelations that might arise, or that might bear relevance on today's research and developments in light based sciences, technology, clinical

  18. Seismic and geodetic signatures of fault slip at the Slumgullion Landslide Natural Laboratory

    Science.gov (United States)

    Gomberg, J.; Schulz, W.; Bodin, P.; Kean, J.

    2011-01-01

    We tested the hypothesis that the Slumgullion landslide is a useful natural laboratory for observing fault slip, specifically that slip along its basal surface and side-bounding strike-slip faults occurs with comparable richness of aseismic and seismic modes as along crustal- and plate-scale boundaries. Our study provides new constraints on models governing landslide motion. We monitored landslide deformation with temporary deployments of a 29-element prism array surveyed by a robotic theodolite and an 88-station seismic network that complemented permanent extensometers and environmental instrumentation. Aseismic deformation observations show that large blocks of the landslide move steadily at approximately centimeters per day, possibly punctuated by variations of a few millimeters, while localized transient slip episodes of blocks less than a few tens of meters across occur frequently. We recorded a rich variety of seismic signals, nearly all of which originated outside the monitoring network boundaries or from the side-bounding strike-slip faults. The landslide basal surface beneath our seismic network likely slipped almost completely aseismically. Our results provide independent corroboration of previous inferences that dilatant strengthening along sections of the side-bounding strike-slip faults controls the overall landslide motion, acting as seismically radiating brakes that limit acceleration of the aseismically slipping basal surface. Dilatant strengthening has also been invoked in recent models of transient slip and tremor sources along crustal- and plate-scale faults suggesting that the landslide may indeed be a useful natural laboratory for testing predictions of specific mechanisms that control fault slip at all scales.

  19. A Cross-Reactive Human Single-Chain Antibody for Detection of Major Fish Allergens, Parvalbumins, and Identification of a Major IgE-Binding Epitope.

    Directory of Open Access Journals (Sweden)

    Merima Bublin

    Full Text Available Fish allergy is associated with moderate to severe IgE-mediated reactions to the calcium binding parvalbumins present in fish muscle. Allergy to multiple fish species is caused by parvalbumin-specific cross-reactive IgE recognizing conserved epitopes. In this study, we aimed to produce cross-reactive single chain variable fragment (scFv antibodies for the detection of parvalbumins in fish extracts and the identification of IgE epitopes. Parvalbumin-specific phage clones were isolated from the human ETH-2 phage display library by three rounds of biopanning either against cod parvalbumin or by sequential biopanning against cod (Gad m 1, carp (Cyp c 1 and rainbow trout (Onc m 1 parvalbumins. While biopanning against Gad m 1 resulted in the selection of clones specific exclusively for Gad m 1, the second approach resulted in the selection of clones cross-reacting with all three parvalbumins. Two clones, scFv-gco9 recognizing all three parvalbumins, and scFv-goo8 recognizing only Gad m 1 were expressed in the E. coli non-suppressor strain HB2151 and purified from the periplasm. scFv-gco9 showed highly selective binding to parvalbumins in processed fish products such as breaded cod sticks, fried carp and smoked trout in Western blots. In addition, the scFv-gco9-AP produced as alkaline phosphatase fusion protein, allowed a single-step detection of the parvalbumins. In competitive ELISA, scFv-gco9 was able to inhibit binding of IgE from fish allergic patients' sera to all three β-parvalbumins by up to 80%, whereas inhibition by scFv-goo8 was up to 20%. 1H/15N HSQC NMR analysis of the rGad m 1:scFv-gco9 complex showed participation of amino acid residues conserved among these three parvalbumins explaining their cross-reactivity on a molecular level. In this study, we have demonstrated an approach for the selection of cross-reactive parvalbumin-specific antibodies that can be used for allergen detection and for mapping of conserved epitopes.

  20. A Cross-Reactive Human Single-Chain Antibody for Detection of Major Fish Allergens, Parvalbumins, and Identification of a Major IgE-Binding Epitope.

    Science.gov (United States)

    Bublin, Merima; Kostadinova, Maria; Fuchs, Julian E; Ackerbauer, Daniela; Moraes, Adolfo H; Almeida, Fabio C L; Lengger, Nina; Hafner, Christine; Ebner, Christof; Radauer, Christian; Liedl, Klaus R; Valente, Ana Paula; Breiteneder, Heimo

    2015-01-01

    Fish allergy is associated with moderate to severe IgE-mediated reactions to the calcium binding parvalbumins present in fish muscle. Allergy to multiple fish species is caused by parvalbumin-specific cross-reactive IgE recognizing conserved epitopes. In this study, we aimed to produce cross-reactive single chain variable fragment (scFv) antibodies for the detection of parvalbumins in fish extracts and the identification of IgE epitopes. Parvalbumin-specific phage clones were isolated from the human ETH-2 phage display library by three rounds of biopanning either against cod parvalbumin or by sequential biopanning against cod (Gad m 1), carp (Cyp c 1) and rainbow trout (Onc m 1) parvalbumins. While biopanning against Gad m 1 resulted in the selection of clones specific exclusively for Gad m 1, the second approach resulted in the selection of clones cross-reacting with all three parvalbumins. Two clones, scFv-gco9 recognizing all three parvalbumins, and scFv-goo8 recognizing only Gad m 1 were expressed in the E. coli non-suppressor strain HB2151 and purified from the periplasm. scFv-gco9 showed highly selective binding to parvalbumins in processed fish products such as breaded cod sticks, fried carp and smoked trout in Western blots. In addition, the scFv-gco9-AP produced as alkaline phosphatase fusion protein, allowed a single-step detection of the parvalbumins. In competitive ELISA, scFv-gco9 was able to inhibit binding of IgE from fish allergic patients' sera to all three β-parvalbumins by up to 80%, whereas inhibition by scFv-goo8 was up to 20%. 1H/15N HSQC NMR analysis of the rGad m 1:scFv-gco9 complex showed participation of amino acid residues conserved among these three parvalbumins explaining their cross-reactivity on a molecular level. In this study, we have demonstrated an approach for the selection of cross-reactive parvalbumin-specific antibodies that can be used for allergen detection and for mapping of conserved epitopes.

  1. Effect of experimental ileitis on expression of tlr-2 in lymphfocytes of small intestine

    Directory of Open Access Journals (Sweden)

    A. S. Zherebiatiev

    2013-08-01

    Full Text Available Introduction Crohn’s disease and ulcerative colitis are the main clinical phenotypes of inflammatory bowel disease (IBD. Both forms of IBD can increase the incidence of gastrointestinal and colon cancers, and both ones are associated with significant morbidity and mortality worldwide. In addition, they can begin early in life and persist for long periods. The pathogenesis of IBD is complex and multifactorial. Differential alteration of Toll-like receptor (TLR expression in inflammatory bowel disease was first described 15 years ago. Studies have led to the current concept that TLRs represent key mediators of innate host defense in the intestine, and they are involved in mucosa maintaining as well as commensal homeostasis. Recent findings in diverse murine models of ileitis have helped to reveal the importance of TLR dysfunction mechanisms in IBD pathogenesis. The aim of research The aim of this study was to investigate the effect of acute ileitis on expression intensity of TLR-2 in lymphocytes of small intestine. Materials and methods Male Wistar rats with weight 200–250 g were housed in standard wire-mesh bottom cages at constant temperature of 25°C and 12/12 h light/dark cycles. The rats were given water and standard laboratory diet with no restriction prior to indomethacin injection. A total number of 20 rats were examined, including control group (n = 10. For induction of acute ileitis, rats received one subcutaneous dose of indomethacin (Sigma, 15 mg/kg. Tissue was examined on the fifth day. For histological examination sections were colored with haematoxylin and eosin. The TLR-2+cells were determined using a direct immunofluorescence technique with using monoclonal rat anti-TLR-2 antibodies. Images were taken by using a fluorescence microscope PrimoStar (ZEISS, Germany with a computer-assisted video system AxioCam 5c (ZEISS, Germany including the NIH-Image software (NIH Image version 1·46. All statistical analyses were performed

  2. [Comparison of film-screen combinations in contrast-detail diagram and with interactive image analysis. 3: Trimodal histograms of gray scale distribution in bar groups of lead pattern images].

    Science.gov (United States)

    Hagemann, G; Eichbaum, G; Stamm, G

    1998-05-01

    The following four screen film combinations were compared: a) a combination of anticrossover film and UV-light emitting screens, b) a combination of blue-light emitting screens and film and c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m3) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analysis was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 micron 2. Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ("mean value method"). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time.

  3. Nitric oxide-dependent vasodilation and Ca2+ signalling induced by erythrodiol in rat aorta

    Directory of Open Access Journals (Sweden)

    Fidèle Ntchapda

    2015-06-01

    Full Text Available Objective: To evaluate the pharmacological property of erythrodiol, a natural triterpenoid contained in propolis, as vasodilatory agent, and to determine its mechanism of action. Methods: Rats aortic rings were isolated and suspended in organ baths, and the effects of erythrodiol were studied by means of isometric tension recording experiments. Nitric oxide (NO was detected by ozone-induced chemiluminescence. The technique used to evaluate changes in intracellular Ca2+ concentration in intact endothelium was opened aortic ring and loaded with 16 µmol Fura-2/AM for 60 min at room temperature, washed and fixed by small pins with the luminal face up. In situ, ECs were visualized by an upright epifluorescence Axiolab microscope (Carl Zeiss, Oberkochen, Germany equipped with a Zeiss×63 Achroplan objective (water immersion, 2.0 mm working distance, 0.9 numerical apertures. ECs were excited alternately at 340 and 380 nm, and the emitted light was detected at 510 nm. Results: In aortic rings with intact endothelium pre-contracted with norepinephrine (10-4 mol/L, the addition of erythrodiol (10-8-10-4 mol/L induced vasorelaxation in a concentration-dependent manner; in endothelium-denuded rings, the relaxant response induced by erythrodiol was almost completely abolished suggesting that vasorelaxation was endothelium-dependent. They had almost no relaxant effect on depolarised or endothelium-denuded aortic segments. The relaxation was significantly attenuated by pre-treatment with the NO synthase inhibitor Nvnitro-L-arginine-methylester. Erythrodiol (10-4 mol/L was able to significantly increase NOx levels. This effect was completely abolished after removal of the vascular endothelium. Erythrodiol (100 µmol/L caused a slow, long-lasting increase in intracellular Ca2+ concentration. These results further supported the hypothesis that erythrodiol can induce activation of the NO/soluble guanylate cyclase/cyclic guanosine monophosphate pathway, as

  4. Efeito do meio Erd Schreiber no cultivo das microalgas Dunaliella salina, Tetraselmis chuii e Isochrysis galbana = Erd Schreiber medium effect in culture of microalgae Dunaliella salina, Tetraselmis chuii and Isochrysis galbana

    Directory of Open Access Journals (Sweden)

    Vera Lucia Mota Klein

    2006-04-01

    Full Text Available As microalgas são utilizadas como fonte de alimento em aqüicultura. Neste trabalho cultivaram-se D. salina, T. chuii e I. galbana. O objetivo do trabalho consistiu em determinar o efeito do meio Erd Schreiber sobre o seu crescimento. Iniciou-se o cultivo com a mistura de 200 mg de Na2HPO4,7H2O, 100 mg de NaNO3 e 50 mL de extrato de solo. No monitoramento, manteve-se a temperatura entre 24 - 28 oC, a salinidade a 34 ppt, à iluminação constante, a densidade celular com uma câmara de Neubauer e um microscópio binocular modelo ZEISS. Como resultado, I. galbana, D. salina e T. chuii atingiram 969 104 cel/mL, 457 x 104 cel/mL e 258,66 x 104 cel/mL, respectivamente, e oscoeficientes angulares b foram 3,76 x 104 cel./mL/dia, 6,84 x 104 cel./mL/dia e 2,08 x 104 cel./mL/dia respectivamente, indicando bom desempenho de todas as microalgas no meio Erd Shreiber.The microalgae is used as food source in aqüicultura. In this work they had cultivated D. salina , T. chuii and I. galbana . The objective of the work is to determine the effect of Erd Schreiber´s culture medium on the microalgae growth. The culture initiated mixting 200mg of Na2HPO4,7H2O, 100 mg of NaNO3 and 50 mL of soil extract. During the culture the temperature had varied between 24 and 28oC, the salinity was fixed on 34 %o, and the illumination was maintained constant. The assessment of the culture was made by a chamber of Neubauer and a binocular microscope ZEISS model. As result I. galbana D. salina and T.chuii reached 969 104 cel/mL, 457 x 104cel/mL and 258,66 x 104 cel/mL respectively and as angular coefficient 3,76 x 104 cel/mL/dia, 6,84 x 104 cel/mL/dia and 2,08 104 x cel/mL/dia respectively, showing good answer of the microalgae to the effect of Erd Schreiber´ s medium.

  5. Wilhelm Winkler (1842-1910) - a Thuringian private astronomer and maecenas

    Science.gov (United States)

    Weise, Wilfried; Dorschner, Johann; Schielicke, Reinhardt E.

    Wilhelm Winkler was born in 1842 in Eisenberg, Thuringia, as the son of a lawyer. After attending the trading high school in Gera, Winkler worked as a merchant in Eisenberg, following in the footsteps of his grandfather. In 1875 he gave up this trade and devoted his time entirely to astronomy. Advised by Carl Bruhns, director of the Leipzig University Observatory, he established an observatory on his estate in Gohlis near Leipzig. From 1878 Winkler regularly observed sunspots; other fields of his observational interests were comets, occultations of stars by the Moon, and Jupiter's satellites. In 1887 he went to Jena, where he contacted Ernst Abbe, who was the head of the Jena observatory, too. For some years, Winkler's instruments were used in the new observatory erected by Abbe, which replaced the old Ducal Observatory of the Goethe era. Winkler donated the precision pendulum clock and some other instruments to this observatory. He also offered his observational assistance whenever it was wanted. In 1893 Winkler built up his own observatory in Jena and published annual reports on his work in the Vierteljahrsschrift of the Astronomische Gesellschaft. His observational results mainly appeared in the journal Astronomische Nachrichten. In 1902 he was awarded an honorary doctor's degree by the Philosophical Faculty of Jena University. However, at that time his physical constitution began gradually to fade. He lost his left eye due to a sarcoma, and finally he died at the age of 68. In his will, he left 100 000 Mark in form of securities to Jena University (Winkler Foundation). The University Observatory got his 4.5 m dome, the transport of which from his residence to the final site was also paid for by him, several instruments, and a lot of books. In 1936 Winkler's dome was closed by the University. The observatory was transferred from the University to the Zeiss works in exchange for the observatory in the Jena Forst. Zeiss sponsored the reconstruction of the old dome

  6. A possible early sign of hydroxychloroquine macular toxicity.

    Science.gov (United States)

    Brandao, Livia M; Palmowski-Wolfe, Anja M

    2016-02-01

    Hydroxychloroquine (HCQ) has a low risk of retinal toxicity which increases dramatically with a cumulative dose of >1000 g. Here we report a case of HCQ macular toxicity presentation in a young patient with a cumulative dose of 438 g. A 15-year-old female started attending annual consultations for retinal toxicity screening in our clinic after 3 years of HCQ treatment for juvenile idiopathic dermatomyositis. She had been diagnosed at age 12 and had been on hydroxychloroquine 200 mg/day, cyclosporin 150 mg/day and vitamin D3 since. Screening consultations included: complete ophthalmologic examination, automated perimetry (AP, M Standard, Octopus 101, Haag-Streit), multifocal electroretinogram (VERIS 6.06™, FMSIII), optical coherence tomography (OCT, fast macular protocol, Cirrus SD-OCT, Carl Zeiss), fundus autofluorescence imaging (Spectralis OCT, Heidelberg Engineering Inc.) and color testing (Farnsworth-Panel-D-15). After 5 years of treatment, AP demonstrated reduced sensibility in only one extra-foveal point in each eye (p < 0.2). Even though other exams showed no alteration and the cumulative dose was only around 353 g, consultations were increased to every 6 months. After 2-year follow-up, that is, 7 years of HCQ, a bilateral paracentral macula thinning was evident on OCT, suggestive of bull's eye maculopathy. However, the retinal pigmented epithelium appeared intact and AP was completely normal in both eyes. Further evaluation with ganglion cell analysis (GCA = ganglion cell + inner plexiform layer, Cirrus SD-OCT, Carl Zeiss) showed a concentric thinning of this layer in the same area. Although daily and cumulative doses were still under the high toxicity risk parameters, HCQ was suspended. At a follow-up 1 year later, visual acuity was 20/16 without any further changes in OCT or on any other exam. This may be the first case report of insidious bull's eye maculopathy exclusively identified using OCT thickness analysis, in a patient in whom both cumulative

  7. MORPHOLOGICAL CHANGES IN THE HIPPOCAMPUS OF RATS IN ACCELERATED AGING

    Directory of Open Access Journals (Sweden)

    K. Yu. Maksimova

    2014-01-01

    Full Text Available The aim of this work was the analysis of structural changes with age in the hippocampus of senescenceaccelerated OXYS rats when signs of accelerated brain aging are missing (age 14 days, developments (age 5 months, and active progresses (age 15 months. The study was performed on 15 OXYS rats and 15 Wistar rats (as a control. After dislocation, brains were dissected, fixed with 10% formalin, embedded in paraffin, and serially cut in coronal sections (5μm thickness. These sections were stained with Cresyl violet and examined with a photomicroscope (Carl Zeiss Axiostar plus, Germany. The total number of hippocampal pyramidal cells in the CA1, CA3 and the dentate gyrus regions were estimated in 14-dayold, 5and 15-month-old OXYS and Wistar rats (n = 5 on the 5 slices of each brain sections. The number of neurons with chromatolysis, hyperchromatic with darkly stained cytoplasm and shrunken neurons were calculated as degenerative neurons. The pictures obtained with the program Carl Zeiss Axio Vision 8.0 with increasing 10  100, determined the average area bodies and nuclei of neurons (mkm2. The significant structural changes of neurons in the CA1, CA3 and dentate gyrus regions of the hippocampus in OXYS rats at 5 month of age are revealed by light microscopy. This results indicates the early develop neurodegeneration in OXYS rats. The most pronounced morphological changes occur in the CA1 region of the hippocampus of OXYS rats and irreversible. The degenerative changes of neurons in the hippocampus increases by the age of 15 months. Morphometric analysis of the average area of bodies and the nuclei of hippocampal neurons in CA1, CA3 and the dentate gyrus regions of OXYS and Wistar rats at 14 days of age showed no significant interline differences. At 5 months of age in the CA1 region of the hippocampus of OXYS rats was determined a significantly lower average body size and nuclei of pyramidal neurons compared with Wistar rats. With age, these

  8. VARIABILITY IN FOVEAL AVASCULAR ZONE AND CAPILLARY DENSITY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY MACHINES IN HEALTHY EYES.

    Science.gov (United States)

    Magrath, George N; Say, Emil Anthony T; Sioufi, Kareem; Ferenczy, Sandor; Samara, Wasim A; Shields, Carol L

    2017-11-01

    To evaluate the variability in foveal avascular zone (FAZ) and capillary density measurements on optical coherence tomography angiography using Optovue RTVue XR Avanti (OA) (Optovue) and Zeiss Cirrus HD-OCT 5000 (ZC) (Carl Zeiss Meditec). In this prospective, comparative case series, parafoveal (3 × 3 mm) optical coherence tomography angiography scans were obtained on healthy volunteers using both the Avanti and Cirrus. The FAZ area and capillary density at the level of both the superficial and deep capillary plexus were measured automatically using the built-in ReVue software (Optovue) with the Avanti as well as manually using ImageJ (National Institutes of Health) with both machines. There were 50 eyes in 25 healthy volunteers included in the analysis. Mean subject age was 33 years and there were 14 women (56%). On optical coherence tomography, mean central macular thickness was significantly greater on OA (259.1 μm) than ZC (257.6 μm, P = 0.0228). On optical coherence tomography angiography, mean superficial and deep plexus FAZ measured 0.2855 mm and 0.3465 mm on Avanti automated (A-A), 0.2739 mm and 0.3637 mm on Avanti manual (A-M), and 0.2657 mm and 0.3993 mm on Cirrus manual (C-M), respectively. There were no statistically significant differences in superficial plexus FAZ measurements between the A-A and A-M (P = 0.4019) or A-A and C-M (P = 0.1336). The A-M measured significantly larger than C-M (P = 0.0396). Deep plexus FAZ measurements were similar on A-A and A-M (P = 0.6299), but both were significantly less compared with C-M (P machine and technique are consistent and reliable between fellow eyes, significant variability exists in FAZ and capillary density measurements among different machines and techniques. Comparison of measurements across machines and techniques should be considered with caution.

  9. Clinical Prediction Performance of Glaucoma Progression Using a 2-Dimensional Continuous-Time Hidden Markov Model with Structural and Functional Measurements.

    Science.gov (United States)

    Song, Youngseok; Ishikawa, Hiroshi; Wu, Mengfei; Liu, Yu-Ying; Lucy, Katie A; Lavinsky, Fabio; Liu, Mengling; Wollstein, Gadi; Schuman, Joel S

    2018-03-20

    Previously, we introduced a state-based 2-dimensional continuous-time hidden Markov model (2D CT HMM) to model the pattern of detected glaucoma changes using structural and functional information simultaneously. The purpose of this study was to evaluate the detected glaucoma change prediction performance of the model in a real clinical setting using a retrospective longitudinal dataset. Longitudinal, retrospective study. One hundred thirty-four eyes from 134 participants diagnosed with glaucoma or as glaucoma suspects (average follow-up, 4.4±1.2 years; average number of visits, 7.1±1.8). A 2D CT HMM model was trained using OCT (Cirrus HD-OCT; Zeiss, Dublin, CA) average circumpapillary retinal nerve fiber layer (cRNFL) thickness and visual field index (VFI) or mean deviation (MD; Humphrey Field Analyzer; Zeiss). The model was trained using a subset of the data (107 of 134 eyes [80%]) including all visits except for the last visit, which was used to test the prediction performance (training set). Additionally, the remaining 27 eyes were used for secondary performance testing as an independent group (validation set). The 2D CT HMM predicts 1 of 4 possible detected state changes based on 1 input state. Prediction accuracy was assessed as the percentage of correct prediction against the patient's actual recorded state. In addition, deviations of the predicted long-term detected change paths from the actual detected change paths were measured. Baseline mean ± standard deviation age was 61.9±11.4 years, VFI was 90.7±17.4, MD was -3.50±6.04 dB, and cRNFL thickness was 74.9±12.2 μm. The accuracy of detected glaucoma change prediction using the training set was comparable with the validation set (57.0% and 68.0%, respectively). Prediction deviation from the actual detected change path showed stability throughout patient follow-up. The 2D CT HMM demonstrated promising prediction performance in detecting glaucoma change performance in a simulated clinical setting

  10. DIMENSIONAL VERIFICATION AND QUALITY CONTROL OF IMPLANTS PRODUCED BY ADDITIVE MANUFACTURING

    Directory of Open Access Journals (Sweden)

    Teodor Toth

    2015-07-01

    Full Text Available Purpose: Development of computer technology and alternative manufacturing methods in form of additive manufacturing leads to the manufacture of products with complex shapes. In the field of medicine they include, inter alia, custom-made implants manufactured for a particular patient, such as cranial implants, maxillofacial implants, etc. With regard to the fact that such implants are inserted into a patient’s body, it is necessary to perform the verification, including the shape and dimensional verification. The article deals with the application of the industrial computer tomography within the process of inspection and verification of selected custom-made implant types.Methodology/Approach: The Department of Biomedical Engineering and Measurement performs the verification of medicinal products manufactured by the additive manufacturing technologies from the Ti-6Al-4V (Grade 5 titanium alloy, using the coordinate measuring machine Carl Zeiss Contura G2 and the industrial computed tomography machine Carl Zeiss Metrotom 1500. These equipment fulfil the requirements for the identification and evaluation of dimensions of both, the external and the internal structures. Findings: The article presents the possibilities of the computed tomography utilisation in the inspection of individual implant manufacture using the additive manufacturing technologies. The results indicate that with the adjustment of appropriate input parameters (alignment, this technology is appropriate for the analysis of shape deviations, when compared with the CAD model.Research Limitation/implication: With the increasing distance of measured object from X-ray source, the machine’s resolution function decreases. Decreasing of resolution has a minor impact on the measured dimensions (relatively high tolerances, but has a significant impact on the evaluation of porosity and inclusions. Originality/Value of paper: Currently, the verification of a manufactured implant  can be

  11. Electron energy loss spectroscopy microanalysis and imaging in the transmission electron microscope: example of biological applications

    International Nuclear Information System (INIS)

    Diociaiuti, Marco

    2005-01-01

    This paper reports original results obtained in our laboratory over the past few years in the application of both electron energy loss spectroscopy (EELS) and electron spectroscopy imaging (ESI) to biological samples, performed in two transmission electron microscopes (TEM) equipped with high-resolution electron filters and spectrometers: a Gatan model 607 single magnetic sector double focusing EEL serial spectrometer attached to a Philips 430 TEM and a Zeiss EM902 Energy Filtering TEM. The primary interest was on the possibility offered by the combined application of these spectroscopic techniques with those offered by the TEM. In particular, the electron beam focusing available in a TEM allowed us to perform EELS and ESI on very small sample volumes, where high-resolution imaging and electron diffraction techniques can provide important structural information. I show that ESI was able to improve TEM performance, due to the reduced chromatic aberration and the possibility of avoiding the sample staining procedure. Finally, the analysis of the oscillating extended energy loss fine structure (EXELFS) beyond the ionization edges characterizing the EELS spectra allowed me, in a manner very similar to the extended X-ray absorption fine structure (EXAFS) analysis of the X-ray absorption spectra, to obtain short-range structural information for such light elements of biological interest as O or Fe. The Philips EM430 (250-300 keV) TEM was used to perform EELS microanalysis on Ca, P, O, Fe, Al and Si. The assessment of the detection limits of this method was obtained working with well-characterized samples containing Ca and P, and mimicking the actual cellular matrix. I applied EELS microanalysis to Ca detection in bone tissue during the mineralization process and to P detection in the cellular membrane of erythrocytes treated with an anti-tumoral drug, demonstrating that the cellular membrane is a drug target. I applied EELS microanalysis and selected area electron

  12. Spectral domain OCT versus time domain OCT in the evaluation of macular features related to wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Isola V

    2012-02-01

    Full Text Available Luisa Pierro1, Elena Zampedri1, Paolo Milani2, Marco Gagliardi1, Vincenzo Isola2, Alfredo Pece21Department of Ophthalmology, University Vita-Salute, Scientific Institute San Raffaele, Milano, Italy, 2Fondazione Retina 3000, Milano, ItalyBackground: The aim of this study was to compare the agreement between spectral domain optical coherence tomography (SD OCT and time domain stratus OCT (TD OCT in evaluating macular morphology alterations in wet age-related macular degeneration (AMD.Methods: This retrospective study was performed on 77 eyes of 77 patients with primary or recurring subfoveal choroidal neovascularization secondary to AMD. All patients underwent OCT examination using Zeiss Stratus OCT 3 (Carl Zeiss Meditec Inc, Dublin, CA and Opko OTI Spectral SLO/OCT (Ophthalmic Technologies Inc, Toronto, Canada. In all radial line scans, the presence of intraretinal edema (IRE, serous pigment epithelium detachment (sPED, neurosensory serous retinal detachment (NSRD, epiretinal membrane (EM, inner limiting membrane thickening (ILMT, and hard exudates (HE were evaluated. The degree of matching was quantified by Kappa measure of agreement.Results: The percentage distribution of TD OCT findings versus SD OCT findings was: IRE 36.3% versus 77.9%, sPED 57.1% versus 85.7%, NSRD 38.9% versus 53.2%, EM 10.5% versus 26.3%, ILMT 3.8% versus 32.4%, and HE 6.4% versus 54.5%. The agreement was as follows: sPED: kappa value 0.15; NSRD: kappa value 0.61; IRE: kappa value 0.18; EM: kappa value 0.41; ILMT: kappa value 0.02; HE: kappa value 0.06.Conclusion: The agreement in the evaluation of macular lesions between the two techniques is poor and depends on the lesion considered. SD OCT allows better detection of the alterations typically related to choroidal neovascularization such as IRE, PED, ILM thickening, and HE. Consequently its use should be strongly considered in patients with wet AMD.Keywords: spectral domain, OCT, time domain, macular degeneration, AMD

  13. Outcomes for Myopic LASIK With the MEL 90 excimer laser.

    Science.gov (United States)

    Reinstein, Dan Z; Carp, Glenn I; Lewis, Tariq A; Archer, Timothy J; Gobbe, Marine

    2015-05-01

    To evaluate the visual outcomes of myopic LASIK performed with the MEL 90 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) using the Triple-A profile with a 500-Hz pulse rate. Retrospective analysis of the first 286 myopic LASIK procedures (147 patients) by two experienced surgeons in which the VisuMax femtosecond laser and MEL 90 excimer laser (Carl Zeiss Meditec) were used following a standardized surgical technique. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) up to -10.38 diopters (D), cylinder up to 5.00 D, and corrected distance visual acuity (CDVA) of 20/25 or better. No nomogram adjustments were made. Patients were observed for 3 months. Flap thickness was between 80 and 110 µm and optical zone was between 6 and 7 mm. Standard outcomes analysis was performed. Preoperatively, mean SEQ was -3.83 ± 1.83 D (range: -0.13 to -10.38 D) and mean cylinder was -0.94 ± 0.86 D (range: 0.00 to -5.00 D). Mean age was 36.4 years (range: 18.2 to 74.1 years) with 50% female patients. Of this population, 138 eyes were treated by one surgeon and 148 eyes by another. The mean predictability of SEQ was -0.13 ± 0.34 D (range: -1.00 to +1.00 D). Postoperative SEQ was ± 0.50 D in 88% and ± 1.00 D in 100% of eyes. Preoperative CDVA was 20/20 or better in 97% of eyes. Postoperative uncorrected distance visual acuity was 20/20 or better in 92% and 20/25 or better in 99% of eyes. One line of CDVA was lost in 6% of eyes and no eyes lost two or more lines. There was statistically significant improvement in mesopic contrast sensitivity (CSV-1000) at 3 (P = .021), 6, 12, and 18 (all P ≤.001) cycles per degree. The MEL 90 excimer laser using the Triple-A ablation profile with a 500-Hz pulse rate was found to achieve a small but real increase in contrast sensitivity and high efficacy for myopia up to -10.00 D and cylinder up to 5.00 D without the need for a nomogram adjustment. Copyright 2015, SLACK Incorporated.

  14. Optic coherence tomography in a patient with diffuse unilateral subacute neuroretinitis Tomografia de coerência óptica em neuretinite subaguda difusa unilateral

    Directory of Open Access Journals (Sweden)

    Alexandre Henrique Gomes

    2009-04-01

    Full Text Available PURPOSE: To measure retinal nervous fiber layer (RNFL thickness using OCT3 (Carl-Zeiss in patients with diffuse unilateral subacute neuroretinitis (DUSN with or without live worm and correlate it with visual acuity. METHODS: RNFL thickness, using RNFL thickness 3.4 program and best corrected visual acuity were measured in patients with DUSN between January 2005 and December 2006. RESULTS: Thirty-eight patients, aged 9 - 42 years were selected, of whom 20 had live worm. Mean RNFL was 71.55 ± 27.26 in the DUSN eye and 103.07 ± 20.66 in the contralateral eye (pOBJETIVO: Avaliar o uso do OCT3 (Carl-Zeiss para medir a espessura da camada de fibras nervosas em pacientes com neuroretinite unilateral subaguda difusa (DUSN e correlacionar com a acuidade visual. MÉTODOS: Foi medido a espessura da camada de fibras nervosas, utilizando programa "RNFL thickness 3.4" e a melhor acuidade visual de pacientes com DUSN entre janeiro de 2005 e dezembro 2006. RESULTADOS: Trinta e oito pacientes, com idade entre 9-42 anos foram selecionados para este estudo, sendo que 20 casos apresentavam larva viva localizada. A média da RNFL foi 71,55 ± 27,26 nos olhos com DUSN e 103,07 ± 20,66 nos olhos contralaterais (p<0,001. Correlação de Pearson entre a acuidade visual e a espessura da camada de fibras nervosas foi r= -0,522 (p<0,001 nos olhos com DUSN e r= -0,097 (p=0,509 nos olhos contralaterais. CONCLUSÃO: A espessura da camada de fibras nervosas de pacientes com DUSN apresenta uma correlação diretamente proporcional com a acuidade visual. Novos estudos são necessários para reforçar a correlação entre a acuidade visual e a espessura da camada de fibras nervosas nos pacientes com DUSN com a finalidade de acompanhar os pacientes após o tratamento.

  15. TARGIT-E(lderly—Prospective phase II study of intraoperative radiotherapy (IORT in elderly patients with small breast cancer

    Directory of Open Access Journals (Sweden)

    Neumaier Christian

    2012-05-01

    Full Text Available Abstract Background Patients ≥ 70 years with small, low-risk breast cancer who are operated but not irradiated how local relapse rates around 4% after 4 years. With adjuvant whole breast radiotherapy (WBRT the local relapse rate drops to 1% after 4 years under Tamoxifen. It has been demonstrated that the efficacy of radiotherapy of the tumor bed only in a selected group can be non-inferior to WBRT. Methods/Design This prospective, multicentric single arm phase II study is based on the protocol of the international TARGIT-A study. The TARGIT-E study should confirm the efficacy of a single dose of intraoperative radiotherapy (IORT in a well selected group of elderly patients with small breast cancer and absence of risk factors. Patients will receive IORT (20 Gy with Intrabeam system/Carl Zeiss during breast conserving surgery. In presence of risk factors postoperative WBRT will be added to complete the radiotherapeutic treatment according to international guidelines. Endpoints are the local relapse rate (within 2 cm of the tumor bed, ipsilateral in breast relapse, cancer-specific and overall survival and contralateral breast cancer as well as documentation of quality of life and cosmetic outcome. The expected local relapse rates are 0.5/1/1.5% after 2.5/5/7.5 years, respectively. Discontinuation of the trial is scheduled if rates of local relapse rates rise to 3/4/6% after 2.5/5/7.5 years. Power calculations result in 540 patients with a calculated dropout rate of 20% and loss to follow-up of 20%, an alpha of 0.01 and a beta 0.05. There will be a pre- and a post-pathology stratum (n = 270 each. Discussion It is a pragmatic trial in which each participating centre has the option to modify entry criteria and criteria for WBRT according to this core protocol after consultation with the steering committee and local ethics committee (e.g. size, free margins. Only centers with access to the Intrabeam system (Carl Zeiss can

  16. Quantificação de tecido conjuntivo do músculo cardíaco de cães

    Directory of Open Access Journals (Sweden)

    Hildebrando Gomes Benedicto

    2003-01-01

    Full Text Available Objetivou-se, neste trabalho, estudar a proporção de tecido conjuntivo existente na fração ventricular direita e esquerda do músculo cardíaco de cães, buscando, através da morfometria, dados referentes a inter-relação entre o tecido conjuntivo e o tecido muscular cardíaco, para o conhecimento das relações anátomo-funcionais da estrutura cardíaca, característica de determinados processos ligados a diminuição do trabalho do órgão. Utilizou-se 6 corações de cães SRD, machos e fêmeas, com idade entre 48 e 150 meses, pesando entre 18 e 30 Kg, sem alterações cardíacas, confirmado mediante exames eletrocardiográfico e ecocardiográfico. Preparou-se o material oriundo de três regiões ventriculares em relação a sua base, proximal, média e distal, tanto da face direita quanto da esquerda, segundo as técnicas histológicas convencionais e corados com Picrosirius red, Fucsina-Paraldeido e Tricromo de Gomori, para evidenciação das fibras conjuntivas. As lâminas foram analisadas com auxílio do Axioscópio Zeiss acoplado ao programa de análise de imagens KS-400 Zeiss. A quantidade de tecido conjuntivo no Ventrículo Esquerdo variou de 0,44 a 26,26%; no Ventrículo Direito variou de 0,97 a 21,18%; no ápice variou de 1,32 a 29,24% e no septo interventricular variou de 5,41 a 11,24%. Os resultados obtidos mostram que há uma complexa rede de fibras conjuntivas envolvendo as fibras do tecido muscular cardíaco e que sua quantidade e disposição é muito variada, dependendo da região estudada.

  17. Comparison of screen film combinations: results of a contrast detail study and interactive image quality analysis. Pt. III. Trimodal histograms of grey-value distributions found in the images of grouped lead bar pattern

    International Nuclear Information System (INIS)

    Hagemann, G.; Eichbaum, G.; Stamm, G.

    1998-01-01

    The following four screen film combinations were compared: (a) a combination of anticrossover film and UV-light emitting screens, (b) a combination of blue-light emitting screens and film and (c) two conventional green fluorescing screen film combinations. Radiographs of a specially designed plexiglass phantom (0.2 x 0.2 x 0.12 m 3 ) with bar patterns of lead and plaster and of air, respectively were obtained using the following parameters: 12 pulse generator, 0.6 mm focus size, 4.7 mm aluminum prefilter, a grid with 40 lines/cm (12:1) and a focus-detector distance of 1.15 m. Image analyses was performed using an Ibas system and a Zeiss Kontron computer. Display conditions were the following: display distance 0.12 m, a vario film objective 35/70 (Zeiss), a video camera tube with a PbO photocathode, 625 lines (Siemens Heimann), an Ibas image matrix of 512 x 512 pixels with a spatial resolution of ca. 7 cycles/mm, the projected matrix area was 5000 μm 2 . Maxima in the histograms of a grouped bar pattern were estimated as mean values from the bar and gap regions ('mean value method'). They were used to calculate signal contrast, standard deviations of the means and scatter fraction. Comparing the histograms with respect to spatial resolution and kV setting a clear advantage of the UVR system becomes obvious. The quantitative analysis yielded a maximum spatial resolution of approx. 3 cycles/mm for the UVR system at 60 kV which decreased to half of this value at 117 kV caused by the increasing influence of scattered radiation. A ranking of screen-film systems with respect to image quality and dose requirement is presented. For its evaluation an interactive image analysis using the mean value method was found to be superior to signal/noise ratio measurements and visual analysis in respect to diagnostic relevance and saving of time. (orig./MG) [de

  18. Comparison of retina specialist preferences regarding spectral-domain and swept-source optical coherence tomography angiography

    Directory of Open Access Journals (Sweden)

    Su GL

    2017-05-01

    Full Text Available Grace L Su,1 Douglas M Baughman,2 Qinqin Zhang,3 Kasra Rezaei,2 Aaron Y Lee,2 Cecilia S Lee2 1Lewis Katz School of Medicine, Temple University, Philadelphia, PA, 2Department of Ophthalmology, 3Department of Bioengineering, University of Washington, Seattle, WA, USA Purpose: The aim of this study was to compare physician preferences regarding the commercially available spectral-domain (SD optical coherence tomography angiography (OCTA and swept-source (SS OCTA prototype device.Design: Comparative analysis of diagnostic instruments was performed.Patients and methods: Subjects at the University of Washington Eye Institute and Harborview Medical Center were prospectively recruited and imaged with the Zeiss SD OCTA (HD-5000, Angioplex and Zeiss SS OCTA (Plex Elite, Everest devices on the same day. The study included 10 eyes from 10 subjects diagnosed with a retinal/choroidal disease. Deidentified images were compiled into a survey and sent to retina specialists in various countries. The survey presented masked SD and SS images of each eye for each retinal sublayer side by side. Respondents were asked about their image preference and impact on clinical management. A priori and post hoc preferences for SD vs SS were collected.Results: Fifty-four retina specialists responded to the survey. Median years in practice was 3.00 (interquartile range [IQR] 1.50–17.00. At baseline, 23 (48% physicians owned an OCTA machine. The majority of physician responses showed a preference for the SS over SD OCTA, independent of the retinal pathology shown (n=454 overall responses, 74%. Nevertheless, the majority indicated that both SD and SS would be equally valuable in informing clinical decisions (n=374 overall responses, 61%.Conclusion: These findings indicate that the majority of retina specialists surveyed prefer SS over SD OCTA based on image quality, regardless of the retinal pathology shown. Regarding the clinical utility of each modality, the majority of

  19. A radioecological research on Chilopod species Scolopendra cingulata (Latreille, 1829) from Serbia

    International Nuclear Information System (INIS)

    Antovic, I.; Stojanovic, D.; Svrkota, N.; Zizic, R.; Antic, D.; Antovic, N.M.

    2014-01-01

    In a transition from historical (anthropocentric) to modern (biocentric) approach in radioecological research, animals and plants should be considered not only as contaminants to humans, but also as targets. Therefore, investigations of (as more as possible) various species are warranted. Radioecological research on chilopod species Scolopendra cingulata occurring in Serbia has been performed for the first time. This species (with the Mediterranean zoogeographical affinities) is typical representative of surface soil layers fauna, and the top 5 cm of soil was also analyzed for radioactivity due to some natural radioisotopes and artificial 137 Cs - at the localities were S. cingulata had been sampled. Among individuals of S. cingulata sampled in 2010 and 2012 (at three localities in Serbia - Pcinja, Izbice and Novi Pazar), 10 were included in this analysis. They had been taken (under rocks) by pencers, while their full determination were carried out using binocular ZEISS Discovery V8 stereomicroscope and adequate literature. The ORTEC HPGe spectrometers: GEM-40190, relative efficiency 40 %, and GEM - 30185-S, relative efficiency (35 %) are used to perform radioisotope activity measurements. Those from the 232 Th and 238 U( 226 Ra) series were analyzed (i.e., 228 Ac, 212 Pb, and 214 Pb, 214 Bi - respectively), as well as naturally occurring 40 K, and fission product 137 Cs. They were considered through their intensive (gamma) photopeaks

  20. Structure-function correlations using scanning laser polarimetry in primary angle-closure glaucoma and primary open-angle glaucoma.

    Science.gov (United States)

    Lee, Pei-Jung; Liu, Catherine Jui-Ling; Wojciechowski, Robert; Bailey-Wilson, Joan E; Cheng, Ching-Yu

    2010-05-01

    To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry and visual field (VF) sensitivity in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Prospective, comparative, observational cases series. Fifty patients with POAG and 56 patients with PACG were examined using scanning laser polarimetry with variable corneal compensation (GDx VCC; Laser Diagnostic Technologies, Inc.) and Humphrey VF analyzer (Carl Zeiss Meditec, Inc.) between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity in both decibel and 1/Lambert scales, were estimated by the Spearman rank correlation coefficient (r(s)) and multivariate median regression models (pseudo R(2)). The correlations were determined globally and for 6 RNFL sectors and their corresponding VF regions. The correlation between RNFL thickness and mean sensitivity (in decibels) was weaker in the PACG group (r(s) = 0.38; P = .004; pseudo R(2) = 0.17) than in the POAG group (r(s) = 0.51; P polarimetry. Compared with eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Grain refinement of AZ91D alloy by intensive melt shearing and its persistence after remelting and isothermal holding

    Directory of Open Access Journals (Sweden)

    Zuo Yubo

    2013-01-01

    Full Text Available Intensive melt shearing has a significant grain refining effect on some light alloys. However, the persistence of the grain refining effect during isothermal holding and remelting is still unclear, although it is very important for the practical application. In this study, intensive melt shearing was achieved in a twin-screw mechanism to investigate its grain refining effect on AZ91D magnesium alloy. The refinement mechanism was discussed and the persistence of grain refinement after remelting and isothermal holding was also studied. A Zeiss imaging system with polarized light was used for quantitative measurement of grain size. The results show that the intensive melt shearing has a significant grain refining effect on AZ91D magnesium alloy. With the application of intensive melt shearing, the grain size of AZ91D magnesium alloy can be reduced from 530 μm (for a typical as-cast microstructure to 170 μm, which is about 70% size reduction. The grain refinement achieved by the intensive melt shearing can be partially kept after isothermal holding and remelting. It is believed that the refinement effect was mainly due to the finer and well dispersed oxide particles formed by high intensive shearing. The smaller size of oxide particles and their slow motion velocity in the sheared melt could make important contributions to the remained grain refinement.

  2. Scanning electron microscopy and X-ray energy dispersive spectroscopy - useful tools in the analysis of pharmaceutical products

    Science.gov (United States)

    Sarecka-Hujar, Beata; Balwierz, Radoslaw; Ostrozka-Cieslik, Aneta; Dyja, Renata; Lukowiec, Dariusz; Jankowski, Andrzej

    2017-11-01

    The quality of the drug, its purity and identification of degradation products provide the highest quality of pharmaceutical products. The energy dispersive spectroscopy (EDS) method analyses the percentage of each element form as well as their distribution, and morphological characteristics of the drug form. We analysed the usefulness of EDS method in testing orally disintegrating tablets (ODT) with trimetazidine hydrochloride with high resolution scanning electron microscopy (SEM, SUPRA25 Carl Zeiss company) with spectrophotometer equipped with an X-ray energy dispersion (EDAX Company). The samples of the analysed tablets were imaged after applying conductive layers of gold on their surface. In the EDS analysis the compositions of each sample of the obtained tablets were observed to be virtually identical. The differences in the content of carbon and oxygen came from differences in the composition of particular tablets. The presence of gold in the composition resulted from the sputtering the surface of tablets with gold during the analysis. Knowing the composition of the tablet, SEM-EDS method helps to locate and identify the impurities and degradation products of the compounds, leading to a better understanding of the mechanisms of their formation.

  3. Inter-Rater Reliability of Cyclotorsion Measurements Using Fundus Photography.

    Science.gov (United States)

    Dysli, Muriel; Kanku, Madeleine; Traber, Ghislaine L

    2018-04-01

    The foveo-papillary angle (FPA) on fundus photographs is the accepted standard for the measurement of ocular cyclotorsion. We assessed the inter-rater reliability of this method in healthy subjects and in patients with trochlear nerve palsies. In this methodological study, fundus photographs of healthy subjects and of patients with trochlear nerve palsies were made with a fundus camera (Zeiss Fundus Camera FF 450 plus, Jena, Germany). Three independent observers measured the FPA on the fundus photographs of all subjects in synedra View (synedra View 16, Version 16.0.0.11, Innsbruck, Austria). One hundred and four eyes of 52 subjects (26 healthy controls and 26 patients) were assessed. The mean FPA of the healthy controls was 5.80 degrees (°) [± 0.44 standard error of the mean (SEM)] compared to 11.55° (± 0.80 SEM) for patients with trochlear nerve palsies. The inter-rater reliability of all measured FPAs showed an intraclass correlation coefficient (ICC) of 0.98 (95% CI 0.97 - 0.98). The inter-rater reliability of objective cyclotorsion measurements using fundus photographs was very high. Georg Thieme Verlag KG Stuttgart · New York.

  4. Balancing the shortcomings of microscope and endoscope: endoscope-assisted technique in microsurgical removal of recurrent epidermoid cysts in the posterior fossa.

    Science.gov (United States)

    Ebner, F H; Roser, F; Thaher, F; Schittenhelm, J; Tatagiba, M

    2010-10-01

    We report about endoscope-assisted surgery of epidermoid cysts in the posterior fossa focusing on the application of neuro-endoscopy and the clinical outcome in cases of recurrent epidermoid cysts. 25 consecutively operated patients with an epidermoid cyst in the posterior fossa were retrospectively analysed. Surgeries were performed both with an operating microscope (OPMI Pentero or NC 4, Zeiss Company, Oberkochen, Germany) and endoscopic equipment (4 mm rigid endoscopes with 30° and 70° optics; Karl Storz Company, Tuttlingen, Germany) under continuous intraoperative monitoring. Surgical reports and DVD-recordings were evaluated for identification of adhesion areas and surgical details. 7 (28%) of the 25 patients were recurrences of previously operated epidermoid cysts. Mean time to recurrence was 17 years (8-22 years). In 5 cases the endoscope was used as an adjunctive tool for inspection/endoscope-assisted removal of remnants. The effective time of use of the endoscope was limited to the end stage of the procedure, but was very effective. In a modern operative setting and with the necessary surgical experience recurrent epidermoid cysts may be removed with excellent clinical results. The combined use of microscope and endoscope offers relevant advantages in demanding anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Modern Processing Capabilities of Analog Data from Documentation of the Great Omayyad Mosque in Aleppo, Syria, Damaged in Civil War

    Science.gov (United States)

    Pavelka, K.; Šedina, J.; Raeva, P.; Hůlková, M.

    2017-08-01

    In 1999, a big project for the documentation of the Great Omayyad mosque in Aleppo / Syria under UNESCO was conducted. By end of the last century, still analogue cameras were still being used, like the UMK Zeiss, RolleiMetric System. Digital cameras and digital automatic data processing were just starting to be on the rise and laser scanning was not relevant. In this situation, photogrammetrical measurement used stereo technology for complicated situations, and object and single-image technology for creating photoplans. Hundreds of photogrammetric images were taken. However, data processing was carried out on digital stereo plotters or workstations; it was necessary that all analogue photos were converted to digital form using a photogrammetric scanner. The outputs were adequate to the end of the last century. Nowadays, after 19 years, the photogrammetric materials still exist, but the technology and processing is completely different. Our original measurement is historical and nowadays quite obsolete. So we was it decided to explore the possibilities of the new processing of historical materials. Why? The reason is that in the last few years there has been civil war in Syria and the above mentioned monument was severely damaged. The existing historical materials therefore provide a unique opportunity for possible future reconstruction. This paper refers to the completion of existing materials, their evaluation and possibilities of new processing with today's technologies.

  6. The Influence of Biochemical Modification on the Properties of Adhesive Compounds

    Directory of Open Access Journals (Sweden)

    Anna Rudawska

    2016-12-01

    Full Text Available The main objective of this study was to determine the effect of biochemical modification of epoxy adhesive compounds on the mechanical properties of a cured adhesive exposed to various climatic factors. The epoxy adhesive was modified by lyophilized fungal metabolites and prepared by three methods. Additionally, the adhesive compound specimens were seasoned for two months at a temperature of 50 °C and 50% humidity in a climate test chamber, Espec SH 661. The tensile strength tests of the adhesive compounds were performed using a Zwick/Roell Z150 testing machine in compliance with the DIN EN ISO 527-1 standard. The examination of the adhesive specimens was performed using two microscopes: a LEO 912AB transmission electron microscope equipped with Quantax 200 for EDS X-ray spectroscopy and a Zeiss 510 META confocal microscope coupled to an AxioVert 200M. The experiments involved the use of a CT Skyscan 1172 tomograph. The results revealed that some mechanical properties of the modified adhesives were significantly affected by both the method of preparation of the adhesive compound and the content of the modifying agent. In addition, it was found that seasoning of the modified adhesives does not lead to a decrease in some of their mechanical properties.

  7. Classic Telescopes A Guide to Collecting, Restoring, and Using Telescopes of Yesteryear

    CERN Document Server

    English, Neil

    2013-01-01

    Classic Telescopes explores the exciting world of telescopes past, as well as the possibilities involved in acquiring these instruments. What are classic telescopes? First, the book takes a look at the more traditional telescopes built by the great instrument makers of the eighteenth and nineteenth centuries and the dynastic houses founded by the likes of John Dollond, Alvan Clark, Thomas Cooke & Sons and Carl Zeiss, plus some lesser-known luminaries, including John Brashear, John Calver, and Henry Fitz. Instruments constructed from the 1950s until as recently as the early 1990s are now also considered 'classic.' There is thus a very active market for buying and selling these 'modern' classics. The author examines some of the most talked about instruments on the amateur Internet forums, including the Unitron refractors, the Questar 90, a classic 6-inch reflector, the RV-6; a 3-inch F/15 achromat by Fullerscopes; the time-honored AstroScan Richfield reflector; and many, many more. Classic telescopes are of...

  8. Nephrotoxicity of Bence-Jones proteins: interference in renal epithelial cell acidification

    Directory of Open Access Journals (Sweden)

    Nicastri A.L.

    2002-01-01

    Full Text Available The aim of the present study was to evaluate the acidification of the endosome-lysosome system of renal epithelial cells after endocytosis of two human immunoglobulin lambda light chains (Bence-Jones proteins, BJP obtained from patients with multiple myeloma. Renal epithelial cell handling of two BJP (neutral and acidic BJP was evaluated by rhodamine fluorescence. Renal cells (MDCK were maintained in culture and, when confluent, were incubated with rhodamine-labeled BJP for different periods of time. Photos were obtained with a fluorescence microscope (Axiolab-Zeiss. Labeling density was determined on slides with a densitometer (Shimadzu Dual-Wavelength Flying-Spot Scanner CS9000. Endocytosis of neutral and acidic BJP was correlated with acidic intracellular compartment distribution using acridine orange labeling. We compared the pattern of distribution after incubation of native neutral and acidic BJP and after complete deglycosylation of BJP by periodate oxidation. The subsequent alteration of pI converted neutral BJP to acidic BJP. There was a significant accumulation of neutral BJP in endocytic structures, reduced lysosomal acidification, and a diffuse pattern of acidification. This pattern was reversed after total deglycosylation and subsequent alteration of the pI to an acidic BJP. We conclude that the physicochemical characteristics of BJP interfere with intracellular acidification, possibly explaining the strong nephrotoxicity of neutral BJP. Lysosomal acidification is fundamental for adequate protein processing and catabolism.

  9. Orbital single particle tracking on a commercial confocal microscope using piezoelectric stage feedback

    International Nuclear Information System (INIS)

    Lanzanò, L; Gratton, E

    2014-01-01

    Single Particle Tracking (SPT) is a technique used to locate fluorescent particles with nanometer precision. In the orbital tracking method the position of a particle is obtained analyzing the distribution of intensity along a circular orbit scanned around the particle. In combination with an active feedback this method allows tracking of particles in 2D and 3D with millisecond temporal resolution. Here we describe a SPT setup based on a feedback approach implemented with minimal modification of a commercially available confocal laser scanning microscope, the Zeiss LSM 510, in combination with an external piezoelectric stage scanner. The commercial microscope offers the advantage of a user-friendly software interface and pre-calibrated hardware components. The use of an external piezo-scanner allows the addition of feedback into the system but also represents a limitation in terms of its mechanical response. We describe in detail this implementation of the orbital tracking method and discuss advantages and limitations. As an example of application to live cell experiments we perform the 3D tracking of acidic vesicles in live polarized epithelial cells. (paper)

  10. Influence of Magnetite Nanoparticles on the Dielectric Properties of Metal Oxide/Polymer Nanocomposites Based on Polypropylene

    Science.gov (United States)

    Maharramov, A. A.; Ramazanov, M. A.; Di Palma, Luca; Shirinova, H. A.; Hajiyeva, F. V.

    2018-01-01

    Structure and dielectric properties of polymer nanocomposites based on isotactic polypropylene and iron oxide (Fe3O4) nanoparticles are studied. Distribution of magnetite nanoparticles in a polymer matrix was studied by scanning electron microscopy (SEM, Carl Zeiss). Dielectric properties of nanocomposites were examined by means of E7-21 impedance spectrometer in the frequency range of 102-106 Hz and temperature interval of 298-433 K. The frequency and temperature dependences of the dielectric permittivity ɛ, as well as the temperature dependence of log (ρ) were constructed. It is shown that introduction of the magnetite (Fe3O4) nanoparticles into a polypropylene matrix increases the dielectric permittivity of nanocomposites. An increase in the dielectric permittivity is explained by the increase in the polarization ability of nanocomposites. It is found that a decrease in the specific resistance with increasing temperature up to 318 K is associated with an increase in the ionic conductivity of nanocomposites. An increase in the resistance at temperatures higher than 358 K is due to the destruction of the crystalline phase of the polymer, as a result of which the distance between the Fe3O4 nanoparticles increases.

  11. Monoamine oxidase enzymes and oxidative stress in the rat optic nerve: age-related changes.

    Science.gov (United States)

    Nebbioso, Marcella; Pascarella, Antonia; Cavallotti, Carlo; Pescosolido, Nicola

    2012-12-01

    In this study, age-related changes in the monoamine oxidases (MAO) were studied in the optic nerve (ON) of both young and aged male rats. The aim of the study was to assess the role of MAO in age-related changes in the rat ON and explain the mechanisms of neuroprotection mediated by MAO-B-specific inhibitors. Fifteen three month old and fifteen 26 month old Sprague-Dawley rats were used. The animals were killed by terminal anaesthesia. Staining of MAO, quantitative analysis of images, biochemical assays and statistical analysis of data were carried out. Samples of the ON were washed in water, fixed in Bowen fluid, dehydrated and embedded in Entellan. Histological sections were stained for MAO-enzymatic activities. The specificity of the reaction was evaluated by incubating control sections in a medium either without substrate or without dye. The quantitative analysis of images was carried out at the same magnification and the same lighting using a Zeiss photomicroscope. The histochemical findings were compared with the biochemical results. After enzymatic staining, MAO could be demonstrated in the ON fibres of both young and aged animals; however, MAO were increased in the nerve fibres of the elderly rats. These morphological findings were confirmed biochemically. The possibility that age-related changes in MAO levels may be attributed to impaired energy production mechanisms and/or represent the consequence of reduced energy needs is discussed. © 2012 The Authors. International Journal of Experimental Pathology © 2012 International Journal of Experimental Pathology.

  12. Ultrastructure of the surface of dental enamel with molar incisor hypomineralization (MIH) with and without acid etching.

    Science.gov (United States)

    Bozal, Carola B; Kaplan, Andrea; Ortolani, Andrea; Cortese, Silvina G; Biondi, Ana M

    2015-01-01

    The aim of the present work was to analyze the ultrastructure and mineral composition of the surface of the enamel on a molar with MIH, with and without acid etching. A permanent tooth without clinical MIH lesions (control) and a tooth with clinical diagnosis of mild and moderate MIH, with indication for extraction, were processed with and without acid etching (H3PO4 37%, 20") for observation with scanning electron microscope (SEM) ZEISS (Supra 40) and mineral composition analysis with an EDS detector (Oxford Instruments). The control enamel showed normal prismatic surface and etching pattern. The clinically healthy enamel on the tooth with MIH revealed partial loss of prismatic pattern. The mild lesion was porous with occasional cracks. The moderate lesion was more porous, with larger cracks and many scales. The mineral composition of the affected surfaces had lower Ca and P content and higher O and C. On the tooth with MIH, even on normal looking enamel, the demineralization does not correspond to an etching pattern, and exhibits exposure of crystals with rods with rounded ends and less demineralization in the inter-prismatic spaces. Acid etching increased the presence of cracks and deep pores in the adamantine structure of the enamel with lesion. In moderate lesions, the mineral composition had higher content of Ca, P and Cl. Enamel with MIH, even on clinically intact adamantine surfaces, shows severe alterations in the ultrastructure and changes in ionic composition, which affect the acid etching pattern and may interfere with adhesion.

  13. Optical coherence tomography can be used in evaluation of morphological and functional results after successful rhegmatogenous retinal detachment surgery with different tamponade agents

    Directory of Open Access Journals (Sweden)

    Tat'yana Andreevna Avanesova

    2015-03-01

    Full Text Available Background: Optical coherence tomography (OCT findings are helpful in assessing the cause of reduced visual acuity (VA after successful rhegmatogenous retinal detachment (RRD surgery. Objective: To study anatomical and functional results after successful RRD surgery with gas-air mixture or silicone oil (SO tamponade using OCT. Materials and methods. 70 patients were divided into 2 groups: group I (n = 34 - gas-air mixture tamponade; group II (n = 36 - SO tamponade. At baseline, were no significant differences by gender, age and VA between the groups. Follow-up was 12 months after the surgery. OCT was performed with the Cirrus HD-OCT 4000, CARL ZEISS MEDITEC, USA. Results: VA increased significantly in both groups. Regression analysis showed lower VA in group II and statistically significant association between VA and IS/OS and ELM defects. Сonclusions. There is a strong association of disruption of the IS/OS and ELM with reduced vision after successful retinal detachment surgery. Gas-air mixture tamponade showed some benefits in comparison with SO tamponade.

  14. Mutagenicity potential of commercial broth cubes at varying concentrations

    International Nuclear Information System (INIS)

    De Torres, Nelson Velasquez; Talain, Augusto Nicolas.

    1997-01-01

    Today, there has been a growing concern on the mutagenicity potential of environmental chemical systems. These environmental chemicals such as pesticides, food additives, synthetic drugs, water and atmospheric pollutants are possible causes of mutagenic activity. Meat products and some meat flavorings, were also reported to exhibit mutagenic activity. And since these products are normal part of the daily human diet, there is a need for extensive studies regarding the possible mutagenic activity associated with these products. This study aimed to evaluate the mutagenicity potential of commercial broth cubes at varying concentration. The researchers sought to answer the following questions: 1. Do beef, pork and chicken broth cubes exhibit mutagenic activity? 2. Are there significant differences in the mutagenic activity among the three samples? 3. Are these significant differences in the mutagenic activity exhibited by each of the samples compared to that of Mitomycin-C (positive control)? 4. Which of the sample of each specific concentration exhibit the greatest mutagenic activity? Three specific concentrations of beef, pork and chicken broth cubes were prepared and their mutagenicity potential was evaluated by using the Micronucleus test. The formation of micro nucleated polychromatic and micro nucleated normo chromatic erythrocytes in bone marrow cells of mice treated with these samples were detected using a Carl-Zeiss photo microscope. The statistical tool used to test the validity of the null hypothesis was analysis of variance using randomized complete block design and independent T- test. (author)

  15. Mutagenicity potential of commercial broth cubes at varying concentrations

    Energy Technology Data Exchange (ETDEWEB)

    De Torres, Nelson Velasquez; Talain, Augusto Nicolas

    1998-12-31

    Today, there has been a growing concern on the mutagenicity potential of environmental chemical systems. These environmental chemicals such as pesticides, food additives, synthetic drugs, water and atmospheric pollutants are possible causes of mutagenic activity. Meat products and some meat flavorings, were also reported to exhibit mutagenic activity. And since these products are normal part of the daily human diet, there is a need for extensive studies regarding the possible mutagenic activity associated with these products. This study aimed to evaluate the mutagenicity potential of commercial broth cubes at varying concentration. The researchers sought to answer the following questions: 1. Do beef, pork and chicken broth cubes exhibit mutagenic activity? 2. Are there significant differences in the mutagenic activity among the three samples? 3. Are these significant differences in the mutagenic activity exhibited by each of the samples compared to that of Mitomycin-C (positive control)? 4. Which of the sample of each specific concentration exhibit the greatest mutagenic activity? Three specific concentrations of beef, pork and chicken broth cubes were prepared and their mutagenicity potential was evaluated by using the Micronucleus test. The formation of micro nucleated polychromatic and micro nucleated normo chromatic erythrocytes in bone marrow cells of mice treated with these samples were detected using a Carl-Zeiss photo microscope. The statistical tool used to test the validity of the null hypothesis was analysis of variance using randomized complete block design and independent T- test. (author). 28 refs., 9 figs., 26 tabs.

  16. Image quality comparison of two multifocal IOLs: influence of the pupil.

    Science.gov (United States)

    García-Domene, Mari Carmen; Felipe, Adelina; Peris-Martínez, Cristina; Navea, Amparo; Artigas, Jose M; Pons, Álvaro M

    2015-04-01

    To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany). The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques. In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL. The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm. Copyright 2015, SLACK Incorporated.

  17. Prevalence of Diabetic retinopathy in Kashmir, India - A hospital based study

    Directory of Open Access Journals (Sweden)

    Tariq Qureshi

    2013-03-01

    Full Text Available Objective To assess the prevalence of diabetic retinopathy among Kashmiri population. Material and Method In a cross-sectional hospital based study, 500 patients with established diabetes who attended eye OPD at Govt Medical College Srinagar were evaluated for the presence or absence of retinopathy. Relevant clinical examination was done and the findings were recorded at one point of time. No follow-up findings of the patients were included in this study. Direct Ophthalmoscope (Heinzand slit lamp bio-microscope (Zeiss were used for examination. Statistical package for Social Sciences (SPSS was used for statistical analysis. p60 yrs of age and 49 patients (36.2% were between 40-68 yrs of age. 33 (24.5% were males and 102 (75.5% were females. 30 patients (12.8% with diabetes of = 15 yr. Mild DR was present in 67 (37.4% patients, moderate to severe DR in 46 (9.2% patients, proliferative DR in 5(1% patients and diabetic maculopathy in 17(3.4%patients. Patients who were managed with insulin, either alone or with oral hypoglycemic drugs, had more prevalence of DR. Conclusion The present study concluded that DR is highly prevalent in this part

  18. Alternativa de rehabilitación visual en pacientes con baja visión por afecciones maculares

    Directory of Open Access Journals (Sweden)

    Mayrelis Quintero Busutil

    Full Text Available Objetivo: evaluar los resultados de una modalidad de rehabilitación visual en pacientes con baja visión por afecciones maculares. Método: se realizó un estudio experimental, tipo serie de casos (20 pacientes en el Instituto Cubano de Oftalmología «Ramón Pando Ferrer». Se indicó la realización de ejercicios de localización y relleno. Antes de la rehabilitación y después, se estudió la agudeza visual mejor corregida de cerca con cartilla de Zeiss, velocidad de lectura, presencia de fatiga y rastreo. Resultado: la agudeza visual mejor corregida de cerca mejoró en 16 pacientes que representó el 80 % de los casos estudiados, la velocidad de lectura se incrementó del 73 al 86,5 como promedio; no presentaron fatiga y fue más efectivo el rastreo después de la realización de ejercicios de localización y relleno. Conclusión: la alternativa en la rehabilitación visual de pacientes de baja visión secundaria a afecciones maculares mediante de la realización de ejercicios de localización y relleno, mejora la capacidad visual de los mismos.

  19. Optical coherence tomography in anterior segment imaging

    Science.gov (United States)

    Kalev-Landoy, Maya; Day, Alexander C.; Cordeiro, M. Francesca; Migdal, Clive

    2008-01-01

    Purpose To evaluate the ability of optical coherence tomography (OCT), designed primarily to image the posterior segment, to visualize the anterior chamber angle (ACA) in patients with different angle configurations. Methods In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle configurations including narrow or closed angles and plateau irides, and 10 had normal angle configurations as determined by prior full ophthalmic examination, including slit-lamp biomicroscopy and gonioscopy. Results In all cases, OCT provided high-resolution information regarding iris configuration. The ACA itself was clearly visualized in patients with narrow or closed angles, but not in patients with open angles. Conclusions Stratus OCT offers a non-contact, convenient and rapid method of assessing the configuration of the anterior chamber. Despite its limitations, it may be of help during the routine clinical assessment and treatment of patients with glaucoma, particularly when gonioscopy is not possible or difficult to interpret. PMID:17355288

  20. Indocyanine green videoangiography "in negative": definition and usefulness in spinal dural arteriovenous fistulae.

    Science.gov (United States)

    Simal Julián, Juan Antonio; Miranda Lloret, Pablo; López González, Antonio; Evangelista Zamora, Rocío; Botella Asunción, Carlos

    2013-05-01

    Indocyanine green videoangiography (IGV) has proven its effectiveness in the field of exovascular neurosurgery, both in the intracranial and spinal compartment, but is necessary to define a systematic process for the performance of the IGV to facilitate its interpretation during the procedure. We have defined and applied the concept of videoangiography "in negative" (INIGV) to spinal dural arteriovenous fistulae (dAVF) for the detection and treatment of arteriovenous shunts, so called because the first phase is performed with the vessel suggestive of being pathological occluded. A Pentero-operating microscope with near-infrared IGV-integrated system (Carl Zeiss Co., Germany) was used. At our institution, 24 patients were treated for a spinal dAVF between 1995 and 2011, only in the last 4 cases, INIGV was performed. We describe the IGV in negative procedure and show the most illustrative cases. In all cases, the fistula occlusion was confirmed by postoperative selective digital subtraction angiography (DSA). INIGV demonstrate its capacity in detecting vessels not actually arterialized that should be respected and avoid some of the main limitations of the conventional IGV. This is a technical description about an Indocyanine green (ICG) videoangiographic procedure modification that is superior to merely performing ICG before and after clipping of a dAVF. The INIGV results are rapid and easy to interpret procedure and provide great advantages to the dAVF treatment. Nevertheless, further studies are needed with a larger sample size to determine if INIGV may reduce the need to perform immediate postoperative DSA.

  1. Occurrence and features of uveitis in patients with rheumatic diseases: current peculiarities of clinical examination and patient management.

    Directory of Open Access Journals (Sweden)

    Dzhalavyan Y.V.

    2017-06-01

    Full Text Available The objectives of the study are to establish the occurrence of uveitis in patients with rheumatic diseases, to assess the features of the uveitis in rheumatic disease in children and adults, and to analyze the effectiveness of theirtreatment. Materials and Methods. The study included 670 people with RH (stage I and 35 patients who had uveitis and / or rheumatic fever who agreed to undergo additional ophthalmologic bleeding (stage II, including a standard ophthalmological examination including visiometry, biomicroscopy of the anterior segment, ophthalmoscopy of the posterior segment of the eye, refractometry, optical coherence tomography in angiomode(tomograph-angiograph CIRRUS HD-OCT MODEL 5000 (Carl Zeiss, Germany, dopplerography of the vessels of the eye. Results. The prevalence of uveitis in rheumatic diseases was established in 21%, which is higher than that in the general population. Uveitis in rheumatic diseases is recurrent and well-treated condition with frequent and complete improvement of visual acuity, and angiographycal features of uveitis, p <0,05 for all parameters. Conclusions. The high incidence of uveitis and relapsing their course in rheumatic diseases lead to necessity of an ophthalmologist's examination every 6 months. It is desirable to perform a comprehensive angiographic examination of uvea for the timely detection of erased and subclinical forms of uveitis.

  2. [Peripheral refraction and retinal contour in children with myopia by results of refractometry and partial coherence interferometry].

    Science.gov (United States)

    Tarutta, E P; Milash, S V; Tarasova, N A; Romanova, L I; Markosian, G A; Epishina, M V

    2014-01-01

    To determine the posterior pole contour of the eye based on the relative peripheral refractive error and relative eye length. A parallel study was performed, which enrolled 38 children (76 eyes) with myopia from -1.25 to -10.82 diopters. The patients underwent peripheral refraction assessment with WR-5100K Binocular Auto Refractometer ("Grand Seiko", Japan) and partial coherence tomography with IOLMaster ("Carl Zeiss", Germany) for the relative eye length in areas located 15 and 30 degrees nasal and temporal from the central fovea along the horizontal meridian. In general, refractometry and interferometry showed high coincidence of defocus signs and values for the areas located 15 and 30 degrees nasal as well as 15 degrees temporal from the fovea. However, in 41% of patients defocus signs determined by the two methods mismatched in one or more areas. Most of the mismatch cases were mild myopia. We suppose that such a mismatch is caused by optical peculiarities of the anterior eye segment that have an impact on refractometry results.

  3. Application of OCT in traumatic macular hole

    Directory of Open Access Journals (Sweden)

    Wen-Li Fu

    2017-12-01

    Full Text Available AIM: To observe the application of optical coherence tomography(OCTin the diseases of traumatic macular hole. METHODS: Twenty-five eyes of 23 patients with traumatic macular hole from January 2015 to January 2017 were enrolled in this study, including 9 eyes treated without surgeries, 16 eyes with surgeries. The image features were analyzed using OCT from ZEISS. RESULTS: The OCT characteristics in patients with traumatic macular hole were partial or full-thickness disappearance of the neuro-epithelium. Posterior vitreous detachment was not seen in the traumatic macular hole. OCT examination revealed that 4 eyes had partial detachment of macular hole and 21 eyes had full thickness detachment. Of the twenty-one eyes, 4 eyes had simple macular hole, 10 eyes had macular full-layer division with peripheral nerve epithelium edema, 7 eyes had the macular full-layer hole with the neuro-epithelium localized detachment. In the 25 eyes, 9 eyes did not undergo the surgery, of which 7 eyes were self-healing; 16 eyes were surgically treated. Postoperative OCT showed the macular structure were normal in 12 eyes with the visual acuity improved 3 lines; retinal nerve epithelium were thinning in 4 eyes, visual acuities were not significant improved after surgery. CONCLUSION: OCT examination is necessary for the diagnosis and treatment of traumatic macular hole.

  4. Ciliary body toxicities of systemic oxcarbazepine and valproic acid treatments: electron microscopic study.

    Science.gov (United States)

    Göktaş, Güleser; Aktaş, Zeynep; Erdoğan, Deniz; Seymen, Cemile Merve; Karaca, Emine Esra; Cansu, Ali; Serdaroğlu, Ayşe; Kaplanoğlu, Gülnur Take

    2015-01-01

    Ciliary body is responsible for humour aqueous production in posterior chamber. Valproic acid (VPA) has been widely used for the treatment of epilepsy and other neuropsychiatric diseases such as bipolar disease and major depression. Oxcarbazepine (OXC) is a new anti-epileptic agent that has been used recently for childhood epilepsies such as VPA. In this study, we aimed to investigate the effects of VPA and OXC treatments used as antiepileptic in ciliary body by electron microscopy. In our study, 40 Wistar rats (21 days old) were divided equally into four groups which were applied saline (group 1), VPA (group 2), OXC (group 3) and VPA + OXC (group 4). The as-prepared ocular tissues were characterized by transmission electron microscopy (TEM) technique in scanning and transmission electron microscopy (SEM-TEM) (Carl Zeiss EVO LS10). The results confirmed that VPA caused dense ciliary body degeneration. Additionally, ciliary body degeneration in group 4 was supposed to be due to VPA treatment. Ciliary body damage and secondary outcomes should be considered in patients with long-term VPA therapy.

  5. Large field of view quantitative phase imaging of induced pluripotent stem cells and optical pathlength reference materials

    Science.gov (United States)

    Kwee, Edward; Peterson, Alexander; Stinson, Jeffrey; Halter, Michael; Yu, Liya; Majurski, Michael; Chalfoun, Joe; Bajcsy, Peter; Elliott, John

    2018-02-01

    Induced pluripotent stem cells (iPSCs) are reprogrammed cells that can have heterogeneous biological potential. Quality assurance metrics of reprogrammed iPSCs will be critical to ensure reliable use in cell therapies and personalized diagnostic tests. We present a quantitative phase imaging (QPI) workflow which includes acquisition, processing, and stitching multiple adjacent image tiles across a large field of view (LFOV) of a culture vessel. Low magnification image tiles (10x) were acquired with a Phasics SID4BIO camera on a Zeiss microscope. iPSC cultures were maintained using a custom stage incubator on an automated stage. We implement an image acquisition strategy that compensates for non-flat illumination wavefronts to enable imaging of an entire well plate, including the meniscus region normally obscured in Zernike phase contrast imaging. Polynomial fitting and background mode correction was implemented to enable comparability and stitching between multiple tiles. LFOV imaging of reference materials indicated that image acquisition and processing strategies did not affect quantitative phase measurements across the LFOV. Analysis of iPSC colony images demonstrated mass doubling time was significantly different than area doubling time. These measurements were benchmarked with prototype microsphere beads and etched-glass gratings with specified spatial dimensions designed to be QPI reference materials with optical pathlength shifts suitable for cell microscopy. This QPI workflow and the use of reference materials can provide non-destructive traceable imaging method for novel iPSC heterogeneity characterization.

  6. High-NA EUV lithography enabling Moore's law in the next decade

    Science.gov (United States)

    van Schoot, Jan; Troost, Kars; Bornebroek, Frank; van Ballegoij, Rob; Lok, Sjoerd; Krabbendam, Peter; Stoeldraijer, Judon; Loopstra, Erik; Benschop, Jos P.; Finders, Jo; Meiling, Hans; van Setten, Eelco; Kneer, Bernhard; Kuerz, Peter; Kaiser, Winfried; Heil, Tilmann; Migura, Sascha; Neumann, Jens Timo

    2017-10-01

    While EUV systems equipped with a 0.33 Numerical Aperture lenses are readying to start volume manufacturing, ASML and Zeiss are ramping up their activities on a EUV exposure tool with Numerical Aperture of 0.55. The purpose of this scanner, targeting an ultimate resolution of 8nm, is to extend Moore's law throughout the next decade. A novel, anamorphic lens design, capable of providing the required Numerical Aperture has been investigated; This lens will be paired with new, faster stages and more accurate sensors enabling Moore's law economical requirements, as well as the tight focus and overlay control needed for future process nodes. The tighter focus and overlay control budgets, as well as the anamorphic optics, will drive innovations in the imaging and OPC modelling. Furthermore, advances in resist and mask technology will be required to image lithography features with less than 10nm resolution. This paper presents an overview of the target specifications, key technology innovations and imaging simulations demonstrating the advantages as compared to 0.33NA and showing the capabilities of the next generation EUV systems.

  7. The future of EUV lithography: enabling Moore's Law in the next decade

    Science.gov (United States)

    Pirati, Alberto; van Schoot, Jan; Troost, Kars; van Ballegoij, Rob; Krabbendam, Peter; Stoeldraijer, Judon; Loopstra, Erik; Benschop, Jos; Finders, Jo; Meiling, Hans; van Setten, Eelco; Mika, Niclas; Dredonx, Jeannot; Stamm, Uwe; Kneer, Bernhard; Thuering, Bernd; Kaiser, Winfried; Heil, Tilmann; Migura, Sascha

    2017-03-01

    While EUV systems equipped with a 0.33 Numerical Aperture lenses are readying to start volume manufacturing, ASML and Zeiss are ramping up their development activities on a EUV exposure tool with Numerical Aperture greater than 0.5. The purpose of this scanner, targeting a resolution of 8nm, is to extend Moore's law throughout the next decade. A novel, anamorphic lens design, has been developed to provide the required Numerical Aperture; this lens will be paired with new, faster stages and more accurate sensors enabling Moore's law economical requirements, as well as the tight focus and overlay control needed for future process nodes. The tighter focus and overlay control budgets, as well as the anamorphic optics, will drive innovations in the imaging and OPC modelling, and possibly in the metrology concepts. Furthermore, advances in resist and mask technology will be required to image lithography features with less than 10nm resolution. This paper presents an overview of the key technology innovations and infrastructure requirements for the next generation EUV systems.

  8. Detection of Ustilago nuda (Jensen Rostrup in winter barley seed

    Directory of Open Access Journals (Sweden)

    Ignjatov Maja

    2011-01-01

    Full Text Available Barley is one of the most important cereals grown in our agroecological conditions. The causal agent of loose smut on barley Ustilago nuda (Jensen Rostrup occurs frequently as varieties susceptible to this pathogen are present in the production. Disease symptoms are manifested on barley head (spike. Parasite is transmitted by seed (seedborne and stays in the embryo tissue of the infected kernel as dormant mycelium. Recommended method for detection of U. nuda is given by ISTA Rules (method 7-013. In tests, nine samples (weighing 120 g each of naturally infected barley seed (about 1000 seeds, depending on the absolute mass of seed were examined, observed and described using a Zeiss microscope with sub stage illumination with magnification range x 40 or higher. Mycelium of the fungus approximately 3 μ thick, golden brown in colour was detected and visible without a stain. The percentage of infected embryos in the examined samples of barley seeds ranged from 0.8% to 5.2%.

  9. Using an electron paramagnetic resonance method for testing motor oils

    Energy Technology Data Exchange (ETDEWEB)

    Krais, S; Tkac, T

    1982-01-01

    Using an ER-9 spectrometer from the Karl Zeiss company, the relative effectiveness is studied of antioxidation additives. Motor oils of the E group, M6AD, 465, M6AD, 466, M6AD 467, 15 W/40, S-3/2 M/4, R-950, which contain the antioxidation additive were tested in Petter AV-1 motors at a temperature of 50 degrees for 120 hours and Petter AVB at a temperature of 90 degrees for 53 hours. To measure the concentration of free radicals of the antioxidation additives one part of 2,2-diphenyl-1-picrylhydrazine (I), which forms stable dimagnetic products with the radicals of the antioxidation additives was introduced into each three parts of the oil. The reduction in the intensity of the signal of I was the measure of the radical concentration. The spectrum was taken for 1 to 2 minutes. The graphs of the dependence of the electron paramagnetic resonance on the test time and the concentration of I are built. The beginning and end of the induction period of oxidation of the oils and the change in the hourly activity of the PP was recorded.

  10. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee report on electronic brachytherapy.

    Science.gov (United States)

    Park, Catherine C; Yom, Sue S; Podgorsak, Matthew B; Harris, Eleanor; Price, Robert A; Bevan, Alison; Pouliot, Jean; Konski, Andre A; Wallner, Paul E

    2010-03-15

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site. Copyright 2010. Published by Elsevier Inc.

  11. Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography.

    Science.gov (United States)

    Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe

    2011-03-01

    This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.

  12. Optimization of hole generation in Ti/CFRP stacks

    Science.gov (United States)

    Ivanov, Y. N.; Pashkov, A. E.; Chashhin, N. S.

    2018-03-01

    The article aims to describe methods for improving the surface quality and hole accuracy in Ti/CFRP stacks by optimizing cutting methods and drill geometry. The research is based on the fundamentals of machine building, theory of probability, mathematical statistics, and experiment planning and manufacturing process optimization theories. Statistical processing of experiment data was carried out by means of Statistica 6 and Microsoft Excel 2010. Surface geometry in Ti stacks was analyzed using a Taylor Hobson Form Talysurf i200 Series Profilometer, and in CFRP stacks - using a Bruker ContourGT-Kl Optical Microscope. Hole shapes and sizes were analyzed using a Carl Zeiss CONTURA G2 Measuring machine, temperatures in cutting zones were recorded with a FLIR SC7000 Series Infrared Camera. Models of multivariate analysis of variance were developed. They show effects of drilling modes on surface quality and accuracy of holes in Ti/CFRP stacks. The task of multicriteria drilling process optimization was solved. Optimal cutting technologies which improve performance were developed. Methods for assessing thermal tool and material expansion effects on the accuracy of holes in Ti/CFRP/Ti stacks were developed.

  13. An exercise to establish optimum procedures for the characterisation of porosity in UO2 fuel pellets

    International Nuclear Information System (INIS)

    Small, G.J.

    1980-05-01

    A standard metallographic preparation technique for UO 2 is proposed. The criteria for choosing the optimum route are that the specimen should be scratch-free and that the pores inherent to any sintered UO 2 pellet should be neither enlarged nor filled-in during preparation. Having met these criteria one has a specimen suitable for quantitative metallography which can be used to monitor porosity changes due to in-pile sintering. A procedure for analysing the porosity is suggested. This consists of imaging the specimen surface over a range of magnifications using both optical and Scanning Electron Microscopy in order to cover the range of pore sizes of interest (0.1 μm to 10 μm diameter). These images are then analysed to obtain figures for the distribution of pores as a function of diameter. Two methods of pore-size analysis are reviewed, the manual Zeiss Particle Size Analyser and a more sophisticated electronic instrument - the Quantimet. A comparison is made between these two instruments on the basis of accuracy, reproducibility and ease of operation. (author)

  14. Colocalization of coilin and nucleolar proteins in Cajal body-like structures of micronucleated PtK2 cells

    Directory of Open Access Journals (Sweden)

    N.P. Silva

    2004-07-01

    Full Text Available Cajal bodies (CB are ubiquitous nuclear structures involved in the biogenesis of small nuclear ribonucleoproteins and show narrow association with the nucleolus. To identify possible relationships between CB and the nucleolus, the localization of coilin, a marker of CB, and of a set of nucleolar proteins was investigated in cultured PtK2 cells undergoing micronucleation. Nocodazol-induced micronucleated cells were examined by double indirect immunofluorescence with antibodies against coilin, fibrillarin, NOR-90/hUBF, RNA polymerase I, PM/Scl, and To/Th. Cells were imaged on a BioRad 1024-UV confocal system attached to a Zeiss Axiovert 100 microscope. Since PtK2 cells possess only one nucleolus organizer region, micronucleated cells presented only one or two micronuclei containing nucleolus. By confocal microscopy we showed that in most micronuclei lacking a typical nucleolus a variable number of round structures were stained by antibodies against fibrillarin, NOR-90/hUBF protein, and coilin. These bodies were regarded as CB-like structures and were not stained by anti-PM/Scl and anti-To/Th antibodies. Anti-RNA polymerase I antibodies also reacted with CB-like structures in some micronuclei lacking nucleolus. The demonstration that a set of proteins involved in RNA/RNP biogenesis, namely coilin, fibrillarin, NOR-90/hUBF, and RNA polymerase I gather in CB-like structures present in nucleoli-devoid micronuclei may contribute to shed some light into the understanding of CB function.

  15. Intraoperative laser speckle contrast imaging for monitoring cerebral blood flow: results from a 10-patient pilot study

    Science.gov (United States)

    Richards, Lisa M.; Weber, Erica L.; Parthasarathy, Ashwin B.; Kappeler, Kaelyn L.; Fox, Douglas J.; Dunn, Andrew K.

    2012-02-01

    Monitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. Although multiple intraoperative vascular monitoring technologies are currently available, a quantitative method that allows for continuous monitoring is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging method with high spatial and temporal resolution that has been widely used to image CBF in animal models in vivo. In this pilot clinical study, we adapted a Zeiss OPMI Pentero neurosurgical microscope to obtain LSCI images by attaching a camera and a laser diode. This LSCI adapted instrument has been used to acquire full field flow images from 10 patients during tumor resection procedures. The patient's ECG was recorded during acquisition and image registration was performed in post-processing to account for pulsatile motion artifacts. Digital photographs confirmed alignment of vasculature and flow images in four cases, and a relative change in blood flow was observed in two patients after bipolar cautery. The LSCI adapted instrument has the capability to produce real-time, full field CBF image maps with excellent spatial resolution and minimal intervention to the surgical procedure. Results from this study demonstrate the feasibility of using LSCI to monitor blood flow during neurosurgery.

  16. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2015-01-01

    Purpose: To evaluate and compare long-term outcomes ofafter photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. Methods: Retrospective single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK...... or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Results: Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.......69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (P=0.31) before surgery. Average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (PPRK eyes and 1 LASEK eye (P=0.46) had lost 2 lines of corrected distance visual acuity...

  17. APA/APAGS Award for Distinguished Graduate Student in Professional Psychology.

    Science.gov (United States)

    2017-12-01

    The APA/APAGS Award for Distinguished Graduate Student in Professional Psychology is awarded on an annual basis by the APA Board of Professional Affairs (BPA) and the American Psychological Association of Graduate Students (APAGS) to a graduate student who has demonstrated outstanding practice and application of psychology. A qualified candidate must demonstrate exemplary performance in working with an underserved population in an applied setting or have developed an innovative method for delivering health services to an underserved population. The 2017 recipient of the APA/APAGS Award for Distinguished Graduate Student in Professional Psychology was selected by the 2016 Board of Professional Affairs (BPA) and the 2016 APAGS Scholarship and Awards Selection Committee. Members of the 2016 BPA were Antonette M. Zeiss, PhD (Chair); Linda A. Reddy, PhD; Lois O. Condie, PhD; Timothy A. Cavell, PhD; Robert T. Kinscherff, PhD, JD; Jared L. Skillings, PhD, ABPP; Cynthia A. Gómez, PhD; Lisa K. Kearney, PhD, ABPP; and Dinelia Rosa, PhD. Members of the 2016 APAGS Scholarship and Awards Selection Committee were Jerrold Yeo, MA; Jacklynn Fitzgerald, MA; and Roseann Fish Getchell, MA, Med. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Suitability of N2 plasma for the RIE etching of thin Ag layers

    International Nuclear Information System (INIS)

    Hrkut, P.; Matay, L.; Kostic, I.; Bencurova, A.; Konecnikova, A.; Nemec, P.; Andok, R.; Hacsik, S.

    2013-01-01

    Silver layers of 48 nm thickness were evaporated using EB PVD on Si wafers. The masking resist layers were spin-coated and patterned by the EBDW lithography on the ZBA 21 (20 keV) (Carl-Zeiss, Jena; currently Vistec, Ltd.) variable shaped e-beam pattern generator in II SAS. In order to check the etching process in N 2 , we covered a part of the samples containing Ag with a layer of various resists. The samples were dried on a hot-plate and RIE etched in SCM 600 (1 Pa; 20 sccm; 500 W). After 8 minutes the non-masked Ag layer was completely etched away, what testified suitability of N 2 as an etching gas. Also the etch time of 4 minutes showed to be sufficient for etching through the Ag layer. In order to optimize the etching process it was necessary to estimate the etch-rate (E.R.) of suitable resist layers and of the silver layer. The (authors)

  19. Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy

    Directory of Open Access Journals (Sweden)

    Juan Carlos Sánchez Caballero

    2013-04-01

    Full Text Available OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.

  20. Testing EDM of Total Stations

    Directory of Open Access Journals (Sweden)

    Cirbus Ján

    2001-03-01

    Full Text Available The paper is devoted to testing electrooptical distance measuring devices (EDM built in total stations, than can be used for various tasks in the contemporary geodetic works. A rich market offer and availability of these universal measuring systems with satisfying distance range, excellent accuracy and other parameters, make total stations as dominant terrestrial geodetic instruments.For succesfully applying these instruments, above all for relliable distance measurements, the stability of the modulation frequency is the most important pre-condition. In the article, therefore, there are given some methods to verify the modulation frequency stability. In addition, some ways for determining the EDM distance constant and periodical corrections of the phase measuring unit are introduced for 4 types of EDM : LEICA 1700L, TOPCON GTS6A, TOPCON GTS2, C.ZEISS ELTA50. It were also investigated their possibilities for precise distance survey. Values of the determined constants and periodical corrections are presented in Tab. 2.Based on the investigation results of the 4 EDM types and using the values m obtained for different distances S, equations of the a posteriori standard deviations in form : m = (a+b.S were derived too.

  1. OCT angiography of acute non-arteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Rougier, M-B; Delyfer, M-N; Korobelnik, J-F

    2017-02-01

    To describe changes of the retinal peripapillary microvasculature on optical coherence tomography angiography (OCT-A) in non-arteritic anterior ischemic optic (NAION) neuropathy. Observational study of 10 patients at the acute phase of NAION. OCT-A was performed using a 3mm×3mm square centered on the optic disc (Cirrus HD-OCT with Angioplex, Carl Zeiss Meditec, Dublin, CA). A qualitative comparison was made with the healthy fellow eye of each patient. All patients had a fluorescein angiography (HRA2, Heidelberg, Germany) and a visual field examination (Octopus 101 ® , Haag-Streit, USA). In the affected eyes, OCT-A showed clear modifications in the radial peripapillary network. In all these eyes, a focal disappearance of the superficial capillary radial pattern was present, twisted and irregular. In 8 eyes, there was also a lack of vascularization in some focal areas, appearing as dark areas. No correlation was found between the topography of the vascular alteration shown on OCT-A and visual field pattern defects. OCT-A is a new imaging technology able to demonstrate easily and safely the changes in the peripapillary capillary network during the acute phase of NAION. These changes are likely related to a decrease of the prelaminar optic nerve blood flow during the acute phase of NAION. Visual field defects are not correlated with OCT-A images, suggesting that they may be due mainly to disturbances in posterior ciliary artery blood flow. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Semi-automatic geographic atrophy segmentation for SD-OCT images.

    Science.gov (United States)

    Chen, Qiang; de Sisternes, Luis; Leng, Theodore; Zheng, Luoluo; Kutzscher, Lauren; Rubin, Daniel L

    2013-01-01

    Geographic atrophy (GA) is a condition that is associated with retinal thinning and loss of the retinal pigment epithelium (RPE) layer. It appears in advanced stages of non-exudative age-related macular degeneration (AMD) and can lead to vision loss. We present a semi-automated GA segmentation algorithm for spectral-domain optical coherence tomography (SD-OCT) images. The method first identifies and segments a surface between the RPE and the choroid to generate retinal projection images in which the projection region is restricted to a sub-volume of the retina where the presence of GA can be identified. Subsequently, a geometric active contour model is employed to automatically detect and segment the extent of GA in the projection images. Two image data sets, consisting on 55 SD-OCT scans from twelve eyes in eight patients with GA and 56 SD-OCT scans from 56 eyes in 56 patients with GA, respectively, were utilized to qualitatively and quantitatively evaluate the proposed GA segmentation method. Experimental results suggest that the proposed algorithm can achieve high segmentation accuracy. The mean GA overlap ratios between our proposed method and outlines drawn in the SD-OCT scans, our method and outlines drawn in the fundus auto-fluorescence (FAF) images, and the commercial software (Carl Zeiss Meditec proprietary software, Cirrus version 6.0) and outlines drawn in FAF images were 72.60%, 65.88% and 59.83%, respectively.

  3. Cone dysfunctions in retinitis pigmentosa with retinal nerve fiber layer thickening.

    Science.gov (United States)

    Sobacı, Güngör; Ozge, Gökhan; Gündoğan, Fatih Ç

    2012-01-01

    To investigate whether or not thicker retinal nerve fiber layer (RNFL) in retinitis pigmentosa (RP) patients relates to functional abnormalities of the photoreceptors. Optical coherence tomography-based RNFL thickness was measured by Stratus-3™ (Zeiss, Basel, Switzerland) optical coherence tomography and electroretinogram (ERG) recordings made using the RETI-port(®) system (Roland, Wiesbaden, Germany) in 27 patients with retinitis pigmentosa and in 30 healthy subjects. Photopic ERG b-wave amplitude, cone ERG b-wave latency, 30 Hz flicker amplitude, and 30 Hz flicker latency had significant correlations to the RNFL-temporal (r = -0.55, P = 0.004, r = 0.68, P = 0.001, r = -0.65, P = 0.001, and r = -0.52, P = 0.007, respectively). Eyes with thicker RNFL (ten eyes) differed significantly from those with thinner RNFL (eight eyes) regarding cone ERG b-wave latency values only (P = 0.001). Thicker RNFL in patients with retinitis pigmentosa may be associated with functional abnormality of the cone system.

  4. Performance of OCT segmentation procedures to assess morphology and extension in geographic atrophy.

    Science.gov (United States)

    Schütze, Christopher; Ahlers, Christian; Sacu, Stefan; Mylonas, Georgios; Sayegh, Ramzi; Golbaz, Isabelle; Matt, Gerlinde; Stock, Géraldine; Schmidt-Erfurth, Ursula

    2011-05-01

    Investigating segmentation procedures and morphological findings in time domain (TD) and current spectral domain (SD) optical coherence tomography (OCT) devices in patients with geographic atrophy (GA). Fifty eyes of 46 patients with GA secondary to AMD and 15 control eyes were examined in this prospective noninterventional comparative case series. All patients underwent Stratus (model 3000), Cirrus (Carl Zeiss Meditec), Spectralis (Spectralis HRA+OCT; Heidelberg Engineering) and 3D-OCT-1000 (Topcon). Automated segmentation analyses were compared. An overlay of scanning laser ophthalmoscope (SLO) and three-dimensional retinal thickness (RT) maps were used to investigate whether areas of retinal thinning correspond to areas of retinal pigment epithelium (RPE) atrophy. Geographic atrophy areas identified in SLO scans were significantly larger than areas of retinal thinning in RT maps. No convincing topographic correlation could be found between areas of retinal thinning and actual GA size as identified in SLO and fundus photography. Spectralis OCT showed significantly more mild and severe segmentation errors than 3D and Cirrus OCT. This study showed substantial limitations in identifying zones of GA reliably when using automatic segmentation procedures in current SD-OCT devices. This limitation should be addressed to visualize and document RPE loss realistically in a frequent disease like GA. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  5. Diagnostic imaging of cervical intraepithelial neoplasia based on hematoxylin and eosin fluorescence.

    Science.gov (United States)

    Castellanos, Mario R; Szerszen, Anita; Gundry, Stephen; Pirog, Edyta C; Maiman, Mitchell; Rajupet, Sritha; Gomez, John Paul; Davidov, Adi; Debata, Priya Ranjan; Banerjee, Probal; Fata, Jimmie E

    2015-07-25

    Pathological classification of cervical intraepithelial neoplasia (CIN) is problematic as it relies on subjective criteria. We developed an imaging method that uses spectroscopy to assess the fluorescent intensity of cervical biopsies derived directly from hematoxylin and eosin (H&E) stained tissues. Archived H&E slides were identified containing normal cervical tissue, CIN I, and CIN III cases, from a Community Hospital and an Academic Medical Center. Cases were obtained by consensus review of at least 2 senior pathologists. Images from H&E slides were captured first with bright field illumination and then with fluorescent illumination. We used a Zeiss Axio Observer Z1 microscope and an AxioVision 4.6.3-AP1 camera at excitation wavelength of 450-490 nm with emission captured at 515-565 nm. The 32-bit grayscale fluorescence images were used for image analysis. We reviewed 108 slides: 46 normal, 33 CIN I and 29 CIN III. Fluorescent intensity increased progressively in normal epithelial tissue as cells matured and advanced from the basal to superficial regions of the epithelium. In CIN I cases this change was less prominent as compared to normal. In high grade CIN lesions, there was a slight or no increase in fluorescent intensity. All groups examined were statistically different. Presently, there are no markers to help in classification of CIN I-III lesions. Our imaging method may complement standard H&E pathological review and provide objective criteria to support the CIN diagnosis.

  6. Microscope Integrated Intraoperative Spectral Domain Optical Coherence Tomography for Cataract Surgery: Uses and Applications.

    Science.gov (United States)

    Das, Sudeep; Kummelil, Mathew Kurian; Kharbanda, Varun; Arora, Vishal; Nagappa, Somshekar; Shetty, Rohit; Shetty, Bhujang K

    2016-05-01

    To demonstrate the uses and applications of a microscope integrated intraoperative Optical Coherence Tomography in Micro Incision Cataract Surgery (MICS) and Femtosecond Laser Assisted Cataract Surgery (FLACS). Intraoperative real time imaging using the RESCAN™ 700 (Carl Zeiss Meditec, Oberkochen, Germany) was done for patients undergoing MICS as well as FLACS. The OCT videos were reviewed at each step of the procedure and the findings were noted and analyzed. Microscope Integrated Intraoperative Optical Coherence Tomography was found to be beneficial during all the critical steps of cataract surgery. We were able to qualitatively assess wound morphology in clear corneal incisions, in terms of subclinical Descemet's detachments, tears in the inner or outer wound lips, wound gaping at the end of surgery and in identifying the adequacy of stromal hydration, for both FLACS as well as MICS. It also enabled us to segregate true posterior polar cataracts from suspected cases intraoperatively. Deciding the adequate depth of trenching was made simpler with direct visualization. The final position of the intraocular lens in the capsular bag and the lack of bioadhesivity of hydrophobic acrylic lenses were also observed. Even though Microscope Integrated Intraoperative Optical Coherence Tomography is in its early stages for its application in cataract surgery, this initial assessment does show a very promising role for this technology in the future for cataract surgery both in intraoperative decision making as well as for training purposes.

  7. Robotic autopositioning of the operating microscope.

    Science.gov (United States)

    Oppenlander, Mark E; Chowdhry, Shakeel A; Merkl, Brandon; Hattendorf, Guido M; Nakaji, Peter; Spetzler, Robert F

    2014-06-01

    Use of the operating microscope has become pervasive since its introduction to the neurosurgical world. Neuronavigation fused with the operating microscope has allowed accurate correlation of the focal point of the microscope and its location on the downloaded imaging study. However, the robotic ability of the Pentero microscope has not been utilized to orient the angle of the microscope or to change its focal length to hone in on a predefined target. To report a novel technology that allows automatic positioning of the operating microscope onto a set target and utilization of a planned trajectory, either determined with the StealthStation S7 by using preoperative imaging or intraoperatively with the microscope. By utilizing the current motorized capabilities of the Zeiss OPMI Pentero microscope, a robotic autopositioning feature was developed in collaboration with Surgical Technologies, Medtronic, Inc. (StealthStation S7). The system is currently being tested at the Barrow Neurological Institute. Three options were developed for automatically positioning the microscope: AutoLock Current Point, Align Parallel to Plan, and Point to Plan Target. These options allow the microscope to pivot around the lesion, hover in a set plane parallel to the determined trajectory, or rotate and point to a set target point, respectively. Integration of automatic microscope positioning into the operative workflow has potential to increase operative efficacy and safety. This technology is best suited for precise trajectories and entry points into deep-seated lesions.

  8. Increased-resolution OCT thickness mapping of the human macula: a statistically based registration.

    Science.gov (United States)

    Bernardes, Rui; Santos, Torcato; Cunha-Vaz, José

    2008-05-01

    To describe the development of a technique that enhances spatial resolution of retinal thickness maps of the Stratus OCT (Carl Zeiss Meditec, Inc., Dublin, CA). A retinal thickness atlas (RT-atlas) template was calculated, and a macular coordinate system was established, to pursue this objective. The RT-atlas was developed from principal component analysis of retinal thickness analyzer (RTA) maps acquired from healthy volunteers. The Stratus OCT radial thickness measurements were registered on the RT-atlas, from which an improved macular thickness map was calculated. Thereafter, Stratus OCT circular scans were registered on the previously calculated map to enhance spatial resolution. The developed technique was applied to Stratus OCT thickness data from healthy volunteers and from patients with diabetic retinopathy (DR) or age-related macular degeneration (AMD). Results showed that for normal, or close to normal, macular thickness maps from healthy volunteers and patients with DR, this technique can be an important aid in determining retinal thickness. Efforts are under way to improve the registration of retinal thickness data in patients with AMD. The developed technique enhances the evaluation of data acquired by the Stratus OCT, helping the detection of early retinal thickness abnormalities. Moreover, a normative database of retinal thickness measurements gained from this technique, as referenced to the macular coordinate system, can be created without errors induced by missed fixation and eye tilt.

  9. Hyperspectral fundus imager

    Science.gov (United States)

    Truitt, Paul W.; Soliz, Peter; Meigs, Andrew D.; Otten, Leonard John, III

    2000-11-01

    A Fourier Transform hyperspectral imager was integrated onto a standard clinical fundus camera, a Zeiss FF3, for the purposes of spectrally characterizing normal anatomical and pathological features in the human ocular fundus. To develop this instrument an existing FDA approved retinal camera was selected to avoid the difficulties of obtaining new FDA approval. Because of this, several unusual design constraints were imposed on the optical configuration. Techniques to calibrate the sensor and to define where the hyperspectral pushbroom stripe was located on the retina were developed, including the manufacturing of an artificial eye with calibration features suitable for a spectral imager. In this implementation the Fourier transform hyperspectral imager can collect over a hundred 86 cm-1 spectrally resolved bands with 12 micro meter/pixel spatial resolution within the 1050 nm to 450 nm band. This equates to 2 nm to 8 nm spectral resolution depending on the wavelength. For retinal observations the band of interest tends to lie between 475 nm and 790 nm. The instrument has been in use over the last year successfully collecting hyperspectral images of the optic disc, retinal vessels, choroidal vessels, retinal backgrounds, and macula diabetic macular edema, and lesions of age-related macular degeneration.

  10. [Vitreomacular adhesion in HD-OCT images in the age-related macular degeneration].

    Science.gov (United States)

    Latalska, Małgorzata; Swiech-Zubilewicz, Anna; Mackiewicz, Jerzy

    2013-01-01

    The aim of this study was to evaluate an incidence of the vitreomacular adhesion in patients with age-related macular degeneration. We examined 472 eyes in 241 patients (136 W/ 105 M) in age of 54-92 years (mean 62.6 years +/- 8.5) with dry or wet age-related macular degeneration using Cirrus HD-OCT (Zeiss) macular cube 512x128 program or 5-line pro-gram. Vitreomacular adhesion was observed in 139 eyes with dry age-related macular degeneration (29.4%, p=0.000*), in 101 eyes with drusen (21.4%, p=0.000*), in 38 eyes with retinal pigment epithelium alterations (8%, p=0.202), in 278 eyes with wet age-related macular degeneration (58.9%, p=0.001*), in 21 eyes with pigment epithelial detachment (4.4%, p=0.303), in 161 eyes with choroidal neovascularzation (34. 1%, p=0.031*/ and in 96 eyes with scar (20.4%, p=0.040*). Probably, vitreomacular adhesion alone is not able to induce age-related macular degeneration, but it may be associated with choroidal neovascularization development, it can contribute to exudate formation and choroidal neovascularization, it may induces or sustains a chronic low-grade inflammation in the macula region.

  11. Fluorescent angiography and optical coherence tomography with angiography of the ocular fundus in patients with "the wet" form of an age-related macular degeneration.

    Directory of Open Access Journals (Sweden)

    Virsta A.M.

    2017-06-01

    Full Text Available Purpose: to investigate the informative value of fluorescent angiography (FA and optical coherence tomography with fundus angiography (angio-OCT in the diagnosis of "wet" form of age-related macular degeneration (AMD. Material and methods. The present study included 20 patients (20 eyes diagnosed with degeneration of macula and posterior pole of the eye, the "wet" form (late stage age-related macular degeneration, AREDS category 4. The study used machines: optical coherence tomography, Spectralis HRA+OCT (Heidelberg Engeneering, Germany, optical со- herence tomography-angiography CIRRUS HD-OCT MODEL 5000 (Carl Zeiss, Germany. Results. When conducting the FA, in 11 patients found the ill-defined zone of small leakage of dye in 7 patients revealed a clearly defined area of hyperfluorescence in the early phase, and marked leakage of dye in the late phase, 2 patients — uncertain indices. In connection with the received data questionable PHAGE in 11 patients, all were held angio-OCT, to clarify the localization of choroidal neovascularization (CNV. When performing angio-OCT in 11 patients revealed that "wet" form of AMD with occult choroidal neovascularization. In 7 patients there had been discovered classic CNV in 2 patients combined. Conclusion. Angio-OCT gives a clearer picture about the presence of a choroidal neovascular membrane that plays a significant role in determining the course of treatment of patients with wet age-related macular degeneration.

  12. Agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula in the Reykjavik eye study.

    Science.gov (United States)

    Csutak, A; Lengyel, I; Jonasson, F; Leung, I; Geirsdottir, A; Xing, W; Peto, T

    2010-10-01

    To establish the agreement between image grading of conventional (45°) and ultra wide-angle (200°) digital images in the macula. In 2008, the 12-year follow-up was conducted on 573 participants of the Reykjavik Eye Study. This study included the use of the Optos P200C AF ultra wide-angle laser scanning ophthalmoscope alongside Zeiss FF 450 conventional digital fundus camera on 121 eyes with or without age-related macular degeneration using the International Classification System. Of these eyes, detailed grading was carried out on five cases each with hard drusen, geographic atrophy and chorioretinal neovascularisation, and six cases of soft drusen. Exact agreement and κ-statistics were calculated. Comparison of the conventional and ultra wide-angle images in the macula showed an overall 96.43% agreement (κ=0.93) with no disagreement at end-stage disease; although in one eye chorioretinal neovascularisation was graded as drusenoid pigment epithelial detachment. Of patients with drusen only, the exact agreement was 96.1%. The detailed grading showed no clinically significant disagreement between the conventional 45° and 200° images. On the basis of our results, there is a good agreement between grading conventional and ultra wide-angle images in the macula.

  13. [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry].

    Science.gov (United States)

    Schreiber, W; Vorwerk, C K; Langenbucher, A; Behrens-Baumann, W; Viestenz, A

    2007-04-01

    Goldmann applanation tonometry and dynamic contour tonometry (PASCAL) are two well established slit lamp mounted tonometric methods. Intraocular pressure measurement in bedridden patients and children is often only possible using hand held tonometers (TonoPenXL, Perkins tonometer, Draeger tonometer). This study was performed to evaluate the hand held ICare tonometer, which is based on the rebound method. A total of 102 eyes were examined by two highly experienced ophthalmologists for: 1) ophthalmological status, 2) central corneal power (Zeiss IOL-Master), 3) central corneal thickness (Tomey ultrasound pachymetry, five successive measurements, SDr=0.592-0.642; p<0.001). There was a great intra-individual variability of up to 17 mmHg between the GAT, TonoPenXL and ICare methods. The ICare tonometer is easy to handle and high reliability. The data are comparable with those from the Goldmann tonometer. A tonography effect of 0.6 mmHg in the successive measurement series was found.

  14. Factors affecting the transverse force measurements of an optical trap: I

    Science.gov (United States)

    Wood, Tiffany A.; Wright, Amanda; Gleeson, Helen F.; Dickenson, Mark; Mullin, Tom; Murray, Andrew

    2002-03-01

    The transverse force of an optical trap is usually measured by equating the trapping force to the viscous drag force applied to the trapped particle according to Stokes' Law. Under normal conditions, the viscous drag force on a trapped particle is proportional to the fluid velocity of the medium. In this paper we show that an increase of particle concentration within the medium affects force measurements. In order to trap the particle, 1064 nm light from a Nd:YVO4 laser was brought to a focus in a sample slide, of thickness around 380 microns, by using an inverted Zeiss microscope objective, with NA equals 1.3. The slide was filled with distilled water containing 6 micron diameter polystyrene spheres. Measurements were taken at a fluid velocity of 0.75 microns/sec, achieved by moving the sample stage with a piezo-electric transducer whilst a particle was held stationary in the trap. The laser power required to hold a sphere at different trap depths for various concentrations was measured. Significant weakening of the trap was found for concentrations >0.03% solids by weight, becoming weaker for higher trap depths. These results are explained in terms of aberrations, particle-particle interactions and distortion of the beam due to particle-light interactions.

  15. Ultrastructural features of Mimulus aurantiacus (Scrophulariaceae) pollen tubes in vivo.

    Science.gov (United States)

    Ekici, Nuran; Dane, Feruzan; Olgun, Göksel

    2009-03-01

    The aim of this study is to give information on ultrastructure of in vivo pollen tubes of Mimulus aurantiacus which were collected from the Botanical Garden of the University of California at Berkeley. Materials were prepared according to electron microscopy methods and examined under Zeiss electron microscope. Four zones were examined in the pollen tubes of Mimulus aurantiacus. Apical zone: Mitochondria, smooth endoplasmic reticulum, rough endoplasmic reticulum, dictyosomes and secretory vesicles were observed. Subapical zone: This area contained abundant rough endoplasmic reticulum and occasionally some smooth endoplasmic reticulum. The polysomes, mitochondria, proplastids that contain starch, small vacuoles and a few lipid bodies were detected. Nuclear zone: Both generative and vegetative cell nuclei lie in this zone. The vegetative cell nucleus was large and long. Rough endoplasmic reticulum, mitochondria, ribosomes, dictyosomes, and amyloplasts that are rich of starch were observed. Vacuolation and plug formation zone: Cytoplasm of the tubes was full of large vacuoles. Few organelles such as mitochondria, dictyosome and rough endoplasmic reticulum were detected along their periphery.

  16. MODERN PROCESSING CAPABILITIES OF ANALOG DATA FROM DOCUMENTATION OF THE GREAT OMAYYAD MOSQUE IN ALEPPO, SYRIA, DAMAGED IN CIVIL WAR

    Directory of Open Access Journals (Sweden)

    K. Pavelka

    2017-08-01

    Full Text Available In 1999, a big project for the documentation of the Great Omayyad mosque in Aleppo / Syria under UNESCO was conducted. By end of the last century, still analogue cameras were still being used, like the UMK Zeiss, RolleiMetric System. Digital cameras and digital automatic data processing were just starting to be on the rise and laser scanning was not relevant. In this situation, photogrammetrical measurement used stereo technology for complicated situations, and object and single-image technology for creating photoplans. Hundreds of photogrammetric images were taken. However, data processing was carried out on digital stereo plotters or workstations; it was necessary that all analogue photos were converted to digital form using a photogrammetric scanner. The outputs were adequate to the end of the last century. Nowadays, after 19 years, the photogrammetric materials still exist, but the technology and processing is completely different. Our original measurement is historical and nowadays quite obsolete. So we was it decided to explore the possibilities of the new processing of historical materials. Why? The reason is that in the last few years there has been civil war in Syria and the above mentioned monument was severely damaged. The existing historical materials therefore provide a unique opportunity for possible future reconstruction. This paper refers to the completion of existing materials, their evaluation and possibilities of new processing with today’s technologies.

  17. Emissions of soot particles from heat generators

    Science.gov (United States)

    Lyubov, V. K.; Popov, A. N.; Popova, E. I.

    2017-11-01

    «Soot carbon» or «Soot» - incomplete combustion or thermal decomposition particulate carbon product of hydrocarbons consisting of particles of various shapes and sizes. Soot particles are harmful substances Class 2 and like a dust dispersed by wind for thousands of kilometers. Soot have more powerful negative factor than carbon dioxide. Therefore, more strict requirements on ecological and economical performance for energy facilities at Arctic areas have to be developed to protect fragile Arctic ecosystems and global climate change from degradation and destruction. Quantity of soot particles in the flue gases of energy facilities is a criterion of effectiveness for organization of the burning process. Some of heat generators do not provide the required energy and environmental efficiency which results in irrational use of energy resources and acute pollution of environment. The paper summarizes the results of experimental study of solid particles emission from wide range of capacity boilers burning different organic fuels (natural gas, fuel oil, coal and biofuels). Special attention is paid to environmental and energy performance of the biofuels combustion. Emissions of soot particles PM2.5 are listed. Structure, composition and dimensions of entrained particles with the use of electronic scanning microscope Zeiss SIGMA VP were also studied. The results reveal an impact of several factors on soot particles emission.

  18. Fractographic classification in metallic materials by using 3D processing and computer vision techniques

    Directory of Open Access Journals (Sweden)

    Maria Ximena Bastidas-Rodríguez

    2016-09-01

    Full Text Available Failure analysis aims at collecting information about how and why a failure is produced. The first step in this process is a visual inspection on the flaw surface that will reveal the features, marks, and texture, which characterize each type of fracture. This is generally carried out by personnel with no experience that usually lack the knowledge to do it. This paper proposes a classification method for three kinds of fractures in crystalline materials: brittle, fatigue, and ductile. The method uses 3D vision, and it is expected to support failure analysis. The features used in this work were: i Haralick’s features and ii the fractal dimension. These features were applied to 3D images obtained from a confocal laser scanning microscopy Zeiss LSM 700. For the classification, we evaluated two classifiers: Artificial Neural Networks and Support Vector Machine. The performance evaluation was made by extracting four marginal relations from the confusion matrix: accuracy, sensitivity, specificity, and precision, plus three evaluation methods: Receiver Operating Characteristic space, the Individual Classification Success Index, and the Jaccard’s coefficient. Despite the classification percentage obtained by an expert is better than the one obtained with the algorithm, the algorithm achieves a classification percentage near or exceeding the 60 % accuracy for the analyzed failure modes. The results presented here provide a good approach to address future research on texture analysis using 3D data.

  19. Griffith Observatory: Hollywood's Celestial Theater

    Science.gov (United States)

    Margolis, Emily A.; Dr. Stuart W. Leslie

    2018-01-01

    The Griffith Observatory, perched atop the Hollywood Hills, is perhaps the most recognizable observatory in the world. Since opening in 1935, this Los Angeles icon has brought millions of visitors closer to the heavens. Through an analysis of planning documentation, internal newsletters, media coverage, programming and exhibition design, I demonstrate how the Observatory’s Southern California location shaped its form and function. The astronomical community at nearby Mt. Wilson Observatory and Caltech informed the selection of instrumentation and programming, especially for presentations with the Observatory’s Zeiss Planetarium, the second installed in the United States. Meanwhile the Observatory staff called upon some of Hollywood’s best artists, model makers, and scriptwriters to translate the latest astronomical discoveries into spectacular audiovisual experiences, which were enhanced with Space Age technological displays on loan from Southern California’s aerospace companies. The influences of these three communities- professional astronomy, entertainment, and aerospace- persist today and continue to make Griffith Observatory one of the premiere sites of public astronomy in the country.

  20. Prevalence of Diabetic retinopathy in Kashmir, India -A hospital based study

    Directory of Open Access Journals (Sweden)

    Tariq Qureshi

    2013-01-01

    Full Text Available Objective To assess the prevalence of diabetic retinopathy among Kashmiri population. MaterialandMethod Inacross-sectionalhospitalbasedstudy,500patientswith established diabetes who attended eye OPD at Govt Medical College Srinagar were evaluated for the presence or absence of retinopathy. Relevant clinical examination was done and the findings were recorded at one point of time. No follow-up findings of the patients were included in this study. Direct Ophthalmoscope (Heinzand slit lamp bio-microscope (Zeiss were used for examination. Statistical package for Social Sciences (SPSS was used for statistical analysis. p60 yrs of age and 49 patients (36.2% were between 40-68 yrs of age. 33 (24.5% were males and 102 (75.5% were females. 30 patients (12.8% with diabetes of = 15 yr. Mild DR was present in 67 (37.4% patients, moderate to severe DR in 46 (9.2% patients, proliferative DR in 5(1% patients and diabetic maculopathy in 17(3.4%patients. Patients who were managed with insulin, either alone or with oral hypoglycemic drugs, had more prevalence of DR. Conclusion The present study concluded that DR is highly prevalent in this part of the world and needs early detection and appropriate treatment to prevent blindness due to this condition.

  1. Effect of bleaching on color change and surface topography of composite restorations.

    Science.gov (United States)

    Pruthi, Gunjan; Jain, Veena; Kandpal, H C; Mathur, Vijay Prakash; Shah, Naseem

    2010-01-01

    This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE), Esthet X (Dentsply India), and Admira (Voco, Germany). Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS). 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Dentsply) using SEM. Statistical analysis. One way ANOVA and Multiple comparison tests were used to analyze the data. Statistical significance was declared if the P value was .05 or less. Results and conclusion. All the specimens showed significant discoloration (ΔE > 3.3) after their immersion in solutions representing food and beverages. The total color change after bleaching as compared to baseline color was significant in Filtek Z350 (P = .000) and Esthet X (P = .002), while it was insignificant for Admira (P = .18). Esthet X showed maximum surface roughness followed by Admira and Filtek Z350. Bleaching was effective in reducing the discoloration to a clinically acceptable value in all the three groups (ΔE < 3.3).

  2. Effect of Bleaching on Color Change and Surface Topography of Composite Restorations

    Directory of Open Access Journals (Sweden)

    Gunjan Pruthi

    2010-01-01

    Full Text Available This study was conducted to determine the effect of 15% carbamide peroxide bleaching agent on color change and surface topography of different composite veneering materials (Filtek Z350 (3M ESPE, Esthet X (Dentsply India, and Admira (Voco, Germany. Methods. 30 samples were fabricated for evaluation of color change using CIELAB color system and Gonioreflectometer (GK 311/M, ZEISS. 45 disc-shaped specimens were made for evaluation of surface topography after bleaching (Nupro White Gold; Dentsply using SEM. Statistical analysis. One way ANOVA and Multiple comparison tests were used to analyze the data. Statistical significance was declared if the P value was .05 or less. Results and conclusion. All the specimens showed significant discoloration (ΔE>3.3 after their immersion in solutions representing food and beverages. The total color change after bleaching as compared to baseline color was significant in Filtek Z350 (P=.000 and Esthet X (P=.002, while it was insignificant for Admira (P=.18. Esthet X showed maximum surface roughness followed by Admira and Filtek Z350. Bleaching was effective in reducing the discoloration to a clinically acceptable value in all the three groups (ΔE<3.3.

  3. APA/APAGS Award for Distinguished Graduate Student in Professional Psychology.

    Science.gov (United States)

    2016-11-01

    The APA/APAGS Award for Distinguished Graduate Student in Professional Psychology is awarded on an annual basis by the APA Board of Professional Affairs (BPA) and the American Psychological Association of Graduate Students (APAGS) to a graduate student who has demonstrated outstanding practice and application of psychology. A qualified candidate must demonstrate exemplary performance in working with an underserved population in an applied setting or have developed an innovative method for delivering health services to an underserved population. The 2016 recipient of the APA/APAGS Award for Distinguished Graduate Student in Professional Psychology was selected by the 2015 Board of Professional Affairs (BPA) and the 2015 APAGS Scholarship and Awards Selection Committee. Members of the 2015 BPA were Patricia Arredondo, EdD; Helen L. Coons, PhD, ABPP; Vickie Mays, PhD, MSPH; Linda A. Reddy, PhD; Lois O. Condi, PhD; Antonette M. Zeiss, PhD; Timothy A. Cavell, PhD; Robert T. Kinscherff, PhD, JD; and Jared L. Skillings, PhD, ABPP. Members of the 2015 APAGS Scholarship and Awards Selection Committee were Emily Voelkel, PhD; Blaire Schembari; and Yolanda Perkins-Volk. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  4. [Ophthalmologic reading charts : Part 2: Current logarithmically scaled reading charts].

    Science.gov (United States)

    Radner, W

    2016-12-01

    To analyze currently available reading charts regarding print size, logarithmic print size progression, and the background of test-item standardization. For the present study, the following logarithmically scaled reading charts were investigated using a measuring microscope (iNexis VMA 2520; Nikon, Tokyo): Eschenbach, Zeiss, OCULUS, MNREAD (Minnesota Near Reading Test), Colenbrander, and RADNER. Calculations were made according to EN-ISO 8596 and the International Research Council recommendations. Modern reading charts and cards exhibit a logarithmic progression of print sizes. The RADNER reading charts comprise four different cards with standardized test items (sentence optotypes), a well-defined stop criterion, accurate letter sizes, and a high print quality. Numbers and Landolt rings are also given in the booklet. The OCULUS cards have currently been reissued according to recent standards and also exhibit a high print quality. In addition to letters, numbers, Landolt rings, and examples taken from a timetable and the telephone book, sheet music is also offered. The Colenbrander cards use short sentences of 44 characters, including spaces, and exhibit inaccuracy at smaller letter sizes, as do the MNREAD cards. The MNREAD cards use sentences of 60 characters, including spaces, and have a high print quality. Modern reading charts show that international standards can be achieved with test items similar to optotypes, by using recent technology and developing new concepts of test-item standardization. Accurate print sizes, high print quality, and a logarithmic progression should become the minimum requirements for reading charts and reading cards in ophthalmology.

  5. Carcinoma de glándulas sebáceas limitado a conjuntiva bulbar

    Directory of Open Access Journals (Sweden)

    Manuel Fernando Buitrago-Torrado

    Full Text Available El carcinoma de glándulas sebáceas es un tumor infrecuente que puede desarrollarse a partir de cualquier glándula sebácea en la piel. El 75 % de las veces es de origen ocular y afecta principalmente las glándulas de Zeiss, Meibomio y de la carúncula. Se caracteriza por un comportamiento agresivo, con alta probabilidad de invasión a piel, conjuntiva y córnea. Sin embargo, el compromiso de la conjuntiva como localización primaria es raro. Se presenta un caso con diagnóstico de carcinoma sebáceo de patrón nodular primario de la conjuntiva bulbar, atendido en el Hospital Universitario de Santander durante los años 2014-2016. El propósito del presente estudio es dar a conocer el caso de una patología infrecuente con pocos casos reportados en la literatura, enfatizar su importancia dentro de los diagnósticos diferenciales de masas en la conjuntiva y del estudio histopatológico como método para obtener un diagnóstico definitivo y realizar un abordaje temprano.

  6. Synthesis and structural characterization of bulk Sb2Te3 single crystal

    Science.gov (United States)

    Sultana, Rabia; Gahtori, Bhasker; Meena, R. S.; Awana, V. P. S.

    2018-05-01

    We report the growth and characterization of bulk Sb2Te3 single crystal synthesized by the self flux method via solid state reaction route from high temperature melt (850˚C) and slow cooling (2˚C/hour) of constituent elements. The single crystal X-ray diffraction pattern showed the 00l alignment and the high crystalline nature of the resultant sample. The rietveld fitted room temperature powder XRD revealed the phase purity and rhombohedral structure of the synthesized crystal. The formation and analysis of unit cell structure further verified the rhombohedral structure composed of three quintuple layers stacked one over the other. The SEM image showed the layered directional growth of the synthesized crystal carried out using the ZEISS-EVOMA-10 scanning electron microscope The electrical resistivity measurement was carried out using the conventional four-probe method on a quantum design Physical Property Measurement System (PPMS). The temperature dependent electrical resistivity plot for studied Sb2Te3 single crystal depicts metallic behaviour in the absence of any applied magnetic field. The synthesis as well as the structural characterization of as grown Sb2Te3 single crystal is reported and discussed in the present letter.

  7. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Science.gov (United States)

    2012-01-01

    Background To assess the efficacy, clinical outcomes, visual acuity (VA), incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany) were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%), 20/60 or better in 12 eyes (92%), and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method. PMID:23050659

  8. Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation.

    Science.gov (United States)

    Muallah, Jonas; Wesemann, Christian; Nowak, Roxana; Robben, Jan; Mah, James; Pospiech, Peter; Bumann, Axel

    The aim of this study was to compare the accuracy of six intraoral scanners as regards clinically relevant distances using a new method of evaluation. An additional objective was to compare intraoral scanners with the indirect digitization of model scanners. A resin master model was created by 3D printing and drilled in five places to reflect the following distances: intermolar width (IMW), intercanine width (ICW), and arch length (AL). To determine a gold standard, the distances were measured with a coordinate measuring instrument (Zeiss O-Inspect 422). The master model was scanned 37 times with the following intraoral scanners: Apollo DI (Sirona), CS 3500 (Carestream Dental), iTero (Cadent), PlanScan (Planmeca), Trios (3Shape), and True Definition (3M Espe), and indirectly digitized with the OrthoX Scan (Dentaurum). The digital models were then measured, and deviations from the gold standard calculated. Significant differences were found between the devices. Among the intraoral scanners, Trios and iTero showed the most accurate results, although CS 3500, True Definition, and Apollo DI achieved comparable results. PlanScan demonstrated the highest deviations from the gold standard, and presented a high standard deviation (SD). Direct digitization revealed comparable (and, in fact, slightly higher) accuracy than indirect digitization. Both indirect digitization and most of the intraoral scanners were therefore demonstrated to be suitable for use in the orthodontic office, with the exception of PlanScan, which did not meet the demands of individual orthodontic treatment.

  9. Investigations of Digital Levels at the SLAC Vertical Comparator

    International Nuclear Information System (INIS)

    Gassner, G.

    2005-01-01

    Digital levels deliver highly accurate and fast measurements in an automated measuring process. A shortcoming is that they give less accurate measurements in some cases. There are several sources which are known to have a systematic effect on the height reading and therefore have to be investigated for our equipment. One parameter is the scale factor which has to be determined on a regular basis. Other sources for inaccurate height readings are measurements at critical distances and at the end sections of the rod, a defocused set-up and artificial illumination. With the findings of the experiments investigating the aforementioned error sources, rules for our fieldwork were established. The experiments were carried out with our instruments, a Trimble (formerly Zeiss) DiNi 12 (SW Version 1.21) and a Leica DNA--03 (SW Version 3.40). In some cases, when it is not possible to avoid a critical set-up with the digital leveling system, we use the analog level Wild NA3. Therefore the analog rods have to be also controlled. The calibration is performed with a CCD camera which automatically detects the edges in the image and compares them with the interferometer readings. The CCD camera system is also used to determine the height offset between rods

  10. Intraocular lens iris fixation. Clinical and macular OCT outcomes

    Directory of Open Access Journals (Sweden)

    Garcia-Rojas Leonardo

    2012-10-01

    Full Text Available Abstract Background To assess the efficacy, clinical outcomes, visual acuity (VA, incidence of adverse effects, and complications of peripheral iris fixation of 3-piece acrylic IOLs in eyes lacking capsular support. Thirteen patients who underwent implantation and peripheral iris fixation of a 3-piece foldable acrylic PC IOL for aphakia in the absence of capsular support were followed after surgery. Clinical outcomes and macular SD-OCT (Cirrus OCT; Carl Zeiss Meditec, Germany were analyzed. Findings The final CDVA was 20/40 or better in 8 eyes (62%, 20/60 or better in 12 eyes (92%, and one case of 20/80 due to corneal astigmatism and mild persistent edema. No intraoperative complications were reported. There were seven cases of medically controlled ocular hypertension after surgery due to the presence of viscoelastic in the AC. There were no cases of cystoid macular edema, chronic iridocyclitis, IOL subluxation, pigment dispersion, or glaucoma. Macular edema did not develop in any case by means of SD-OCT. Conclusions We think that this technique for iris suture fixation provides safe and effective results. Patients had substantial improvements in UDVA and CDVA. This surgical strategy may be individualized however; age, cornea status, angle structures, iris anatomy, and glaucoma are important considerations in selecting candidates for an appropriate IOL fixation method.

  11. Comparative analysis of imaging configurations and objectives for Fourier microscopy.

    Science.gov (United States)

    Kurvits, Jonathan A; Jiang, Mingming; Zia, Rashid

    2015-11-01

    Fourier microscopy is becoming an increasingly important tool for the analysis of optical nanostructures and quantum emitters. However, achieving quantitative Fourier space measurements requires a thorough understanding of the impact of aberrations introduced by optical microscopes that have been optimized for conventional real-space imaging. Here we present a detailed framework for analyzing the performance of microscope objectives for several common Fourier imaging configurations. To this end, we model objectives from Nikon, Olympus, and Zeiss using parameters that were inferred from patent literature and confirmed, where possible, by physical disassembly. We then examine the aberrations most relevant to Fourier microscopy, including the alignment tolerances of apodization factors for different objective classes, the effect of magnification on the modulation transfer function, and vignetting-induced reductions of the effective numerical aperture for wide-field measurements. Based on this analysis, we identify an optimal objective class and imaging configuration for Fourier microscopy. In addition, the Zemax files for the objectives and setups used in this analysis have been made publicly available as a resource for future studies.

  12. Long-term Results of Small-incision Lenticule Extraction in High Myopia

    Directory of Open Access Journals (Sweden)

    Yusuf Yıldırım

    2016-10-01

    Full Text Available Objectives: To evaluate two-year results of small-incision lenticule extraction (SMILE for correction of high myopia. Materials and Methods: Forty-five eyes of 35 patients with mean spherical equivalent (SE of -7.10±0.95 D who underwent routine SMILE by a single surgeon and were followed for at least 2 years were analyzed by retrospective chart review. SMILE was performed with a Visumax femtosecond laser (Carl Zeiss Meditec, Jena, Germany. Follow-up intervals were at 1, 6, 12, and 24 months after surgery. Uncorrected and best corrected distance visual acuity (CDVA, corneal wavefront measurements, and all complications were recorded. Results: After 2 years, 86% of eyes with plano target had an uncorrected distant visual acuity (VA of 20/20 or better. Two percent of eyes lost 1 line of CDVA, while 32% gained 1 line. The mean SE after 2 years was -0.30±0.50 D. Corneal total high-order aberrations (HOA increased from 0.43 to 0.92 μm at postoperative 12 months. There were metallic foreign bodies at the corneal interface in 1 eye of 1 patient which caused no decrease in VA. Conclusion: SMILE for high myopia seems safe and effective in light of two-year follow-up results. The procedure caused a moderate increase in HOA.

  13. American Society for Therapeutic Radiology and Oncology (ASTRO) Emerging Technology Committee Report on Electronic Brachytherapy

    International Nuclear Information System (INIS)

    Park, Catherine C.; Yom, Sue S.; Podgorsak, Matthew B.; Harris, Eleanor; Price, Robert A.; Bevan, Alison; Pouliot, Jean; Konski, Andre A.; Wallner, Paul E.

    2010-01-01

    The development of novel technologies for the safe and effective delivery of radiation is critical to advancing the field of radiation oncology. The Emerging Technology Committee of the American Society for Therapeutic Radiology and Oncology appointed a Task Group within its Evaluation Subcommittee to evaluate new electronic brachytherapy methods that are being developed for, or are already in, clinical use. The Task Group evaluated two devices, the Axxent Electronic Brachytherapy System by Xoft, Inc. (Fremont, CA), and the Intrabeam Photon Radiosurgery Device by Carl Zeiss Surgical (Oberkochen, Germany). These devices are designed to deliver electronically generated radiation, and because of their relatively low energy output, they do not fall under existing regulatory scrutiny of radioactive sources that are used for conventional radioisotope brachytherapy. This report provides a descriptive overview of the technologies, current and future projected applications, comparison of competing technologies, potential impact, and potential safety issues. The full Emerging Technology Committee report is available on the American Society for Therapeutic Radiology and Oncology Web site.

  14. Digital fundus image grading with the non-mydriatic Visucam(PRO NM) versus the FF450(plus) camera in diabetic retinopathy.

    Science.gov (United States)

    Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus

    2008-03-01

    Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p camera for applications and clinical trials requiring 7-field stereo photography.

  15. Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.

    Science.gov (United States)

    Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm

    2006-01-01

    To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.

  16. Analysis of the optical emission of the young precataclysmic variables HS 1857+5144 and ABELL 65

    Science.gov (United States)

    Shimansky, V. V.; Pozdnyakova, S. A.; Borisov, N. V.; Bikmaev, I. F.; Vlasyuk, V. V.; Spiridonova, O. I.; Galeev, A. I.; Mel'Nikov, S. S.

    2009-10-01

    We analyze the physical state and the properties of the close binary systems HS 1857+5144 and Abell 65. We took the spectra of both systems over a wide range of orbital phases with the 6-m telescope of the Special Astrophysical Observatory of the Russian Academy of Sciences (SAO RAS) and obtained their multicolor light curves with the RTT150 and Zeiss-1000 telescopes of the SAO RAS. We demonstrate that both Abell 65 and HS 1857+5144 are young precataclysmic variables (PV) with orbital periods of P orb = 1. d 003729 and P orb = 0. d 26633331, respectively. The observed brightness and spectral variations during the orbital period are due to the radiation of the cold component, which absorbs the short-wave radiation of the hot component and reemits it in the visual part of the spectrum. A joint analysis of the brightness and radial velocity curves allowed us to find the possible and optimum sets of their fundamental parameters. We found the luminosity excesses of the secondary components of HS 1857+5144 and Abell 65 with respect to the corresponding Main Sequence stars to be typical for such objects. The excess luminosities of the secondary components of all young PVs are indicative of their faster relaxation rate towards the quiescent state compared to the rates estimated in earlier studies.

  17. Modeling the optical radiation of the precataclysmic variable SDSS J212531-010745

    Science.gov (United States)

    Shimansky, V. V.; Borisov, N. V.; Nurtdinova, D. N.; Solovyeva, Yu. N.; Sakhibullin, N. A.; Spiridonova, O. I.

    2015-03-01

    Optical observations are analyzed to derive a set of basic parameters for the precataclysmic variable star SDSS J212531-010745, whose primary is a PG1159-type star. Spectroscopic and multiband photometric observations of the star were performed in 2008-2011 with the 6-m telescope and the Zeiss-1000 telescope of the Special Astrophysical Observatory. The shape of the binary's orbital light curves is nearly sinusoidal, with the amplitude increasing with wavelength from Δ m = 0.40 m in the B band to Δ m = 0.73 m in the R band. The spectra contain absorption lines of HeII and neutral atoms, along with HI, HeI, CII, MgII, FeII emission lines, whose intensity increases synchronously with the brightness of the system. The optical radiation from SDSS J212531-010745 has a composite nature, corresponding to a model for a pre-cataclysmic variable with strong reflection effects. Cross-correlation techniques are used to measure the radial velocities and derive the component masses. Numerical modeling of the binary's light curves, radial velocities, and spectra is performed, and a complete set of parameters determined. Considerable abundance anomalies (to 1 dex) were detected for the secondary. The primary's characteristics correspond to the evolutionary predictions for DAO dwarfs with masses M ≈ 0.5 M ⊙, and the secondary's characteristics to low-mass, main-sequence stars with the solar metallicity.

  18. Accuracy of a new partial coherence interferometry analyser for biometric measurements.

    Science.gov (United States)

    Holzer, M P; Mamusa, M; Auffarth, G U

    2009-06-01

    Precise biometry is an essential preoperative measurement for refractive surgery as well as cataract surgery. A new device based on partial coherence interferometry technology was tested and evaluated for accuracy of measurements. In a prospective study 200 eyes of 100 healthy phakic volunteers were examined with a functional prototype of the new ALLEGRO BioGraph (Wavelight AG)/LENSTAR LS 900 (Haag Streit AG) biometer and with the IOLMaster V.5 (Carl Zeiss Meditec AG). As recommended by the manufacturers, repeated measurements were performed with both devices and the results compared using Spearman correlation calculations (WinSTAT). Spearman correlation showed high correlations for axial length and keratometry measurements between the two devices tested. Anterior chamber depth, however, had a lower correlation between the two biometry devices. In addition, the mean values of the anterior chamber depth differed (IOLMaster 3.48 (SD 0.42) mm versus BioGraph/LENSTAR 3.64 (SD 0.26) mm); however, this difference was not statistically different (p>0.05, t test). The new biometer provided results that correlated very well with those of the IOLMaster. The ALLEGRO BioGraph/LENSTAR LS 900 is a precise device containing additional features that will be helpful tools for any cataract or refractive surgeon.

  19. A rare variation of the digastric muscle

    Science.gov (United States)

    KALNIEV, MANOL; KRASTEV, DIMO; KRASTEV, NIKOLAY; VIDINOV, KALIN; VELTCHEV, LUDMIL; APOSTOLOV, ALEXANDER; MILEVA, MILKA

    2013-01-01

    The digastric muscle is composed by two muscle bellies: an anterior and a posterior, joined by an intermediate tendon. This muscle is situated in the anterior region of the neck. The region between the hyoid bone and the mandible is divided by an anterior belly into two triangles: the submandibular situated laterally and the submental triangle which is located medially. We found that the anatomical variations described in the literature relate mainly to the anterior belly and consist of differences in shape and attachment of the muscle. During routine dissection in February 2013 in the section hall of the Department of Anatomy and Histology in Medical University – Sofia we came across a very interesting variation of the digastric muscle. The digastric muscles that presented anatomical variations were photographed using a Sony Cyber-shot DSC-T1 camera, with a Carl Zeiss Vario-Tessar lens. We found out bilateral variation of the digastric muscle in one cadaver. The anterior bellies were very thin and insert to the hyoid bone. Two anterior bellies connect each other and thus they formed a loop. The anatomical variations observed of our study related only to the anterior belly, as previously described by other authors. It is very important to consider the occurrence of the above mentioned variations in the digastric muscle when surgical procedures are performed on the anterior region of the neck. PMID:26527971

  20. DIMENSIONAL BEHAVIOR OF THE WOOD OF SAPWOOD AND HEARTWOOD FOR ANALYSIS OF IMAGE SUBMITTED IN DIFFERENT TEMPERATURES

    Directory of Open Access Journals (Sweden)

    Dimas Agostinho da Silva

    2003-01-01

    Full Text Available The objective of this work was to verify the dimensional behavior of heartwood woodand sapwood submitted to different temperatures. It was evaluated volumetric, sectional and lineardimension reduction in heartwood and sapwood of Hymeneae courbaril L submitted to finaltemperatures of 200º, 300º, 400º, 500º, 600º, 700º, 800º and 900°C, in an electric kiln with mediumrate of heating of 1.3ºC/minute. For the measurement of the dimensions, accomplished before andafter the thermal treatments, an image analyzer (Midro-Videomat Zeiss was used. It was obtained,with base in the individual readings accomplished in the image analyzer, the rates of longitudinal andtraverse linear, longitudinal and traverse sectional and volumetric reduction. The results showed thattem- perature increase of 1000C, average reduction rate reached 2.55% and 4.24%, 5.95% and 7.21% and 8.36% in the longitudinal and traverse linear dimensions, longitudinal and traverse sectional andvolumetric, respectively, for heartwood. For sapwood the values were, respectively, 2.64% and 5.02%,6.70% and 8.17% and 9.15%. For both sapwood and heartwood the largest reduction rates occurredin temperatures between 300º and 5000C. The heartwood presented larger resistance to the action ofthe temperature, however its thermal decomposition was more pronounced than that of sapwood inthe temperature range of 200-300 0C. This behavior is similar to that of lignin in relation to cellulose.

  1. Single cells for forensic DNA analysis--from evidence material to test tube.

    Science.gov (United States)

    Brück, Simon; Evers, Heidrun; Heidorn, Frank; Müller, Ute; Kilper, Roland; Verhoff, Marcel A

    2011-01-01

    The purpose of this project was to develop a method that, while providing morphological quality control, allows single cells to be obtained from the surfaces of various evidence materials and be made available for DNA analysis in cases where only small amounts of cell material are present or where only mixed traces are found. With the SteREO Lumar.V12 stereomicroscope and UV unit from Zeiss, it was possible to detect and assess single epithelial cells on the surfaces of various objects (e.g., glass, plastic, metal). A digitally operated micromanipulator developed by aura optik was used to lift a single cell from the surface of evidence material and to transfer it to a conventional PCR tube or to an AmpliGrid(®) from Advalytix. The actual lifting of the cells was performed with microglobes that acted as carriers. The microglobes were held with microtweezers and were transferred to the DNA analysis receptacles along with the adhering cells. In a next step, the PCR can be carried out in this receptacle without removing the microglobe. Our method allows a single cell to be isolated directly from evidence material and be made available for forensic DNA analysis. © 2010 American Academy of Forensic Sciences.

  2. Topographic recording of the Slalom racing route in snow

    Directory of Open Access Journals (Sweden)

    V.F. Giovanis

    2018-02-01

    Full Text Available Purpose: The purpose of the present research was the study and evaluation of the theodolite’s (topographic speedometer use in tracing a path in slalom racing on snow conditions with 58 gates and also to record the optimal method of tracing a slalom route in relation to: a the "velocity" of the race track (degree of difficulty of slalom, b safety of tracing the slalom route. Methods: This research was based on methodology and measurements of a race track in giant slalom with 35 gates in the ski resort "3-5 Pigadia" of Naoussa - Greece. The topographic speedometer was fixed in place at the start of the route. From this point, measurements were taken, for the placement of all 58 gates throughout the route. The measurement was taken using the pole-prism, placed in each interior gate turn, at which the theodolite was aimed. With the help of topographic speedometer the following geometrical parameters have been registered: distance between the gates (Δs, altitude difference of points (Δh with an accuracy up to 1cm, terrain slope (θ, gate angular deviation (δ with an accuracy of up to 1 minute of the angle (°. This allows the creation of the top-view, side-view (profile and three-dimensional aspect of the track, under race conditions on snow and not on dry ground. Results: The correlation coefficient (r between the geometry factor (V.gs and average the above geometry parameters had the following respective values: V.gs -Ms = 0,15, V.gs -Mθ = - 0,52, V.gs -Mδ = - 0,29 for 58 gates on a level of statistical significance of p < 0,05. Conclusions: The first part comprised of 10 gates was the "fastest" (V.gs = 18 degrees of the total slalom route in Naoussa with 58 gates (V.gs = 14 degrees. With the above criteria, slaloms will be compared to each other and will be evaluated against age and safety.

  3. Individual killer whale vocal variation during intra-group behavioral dynamics

    Science.gov (United States)

    Grebner, Dawn M.

    The scientific goal of this dissertation was to carefully study the signal structure of killer whale communications and vocal complexity and link them to behavioral circumstances. The overall objective of this research sought to provide insight into killer whale call content and usage which may be conveying information to conspecifics in order to maintain group cohesion. Data were collected in the summers of 2006 and 2007 in Johnstone Strait, British Columbia. For both individuals and small groups, vocalizations were isolated using a triangular hydrophone array and the behavioral movement patterns were captured by a theodolite and video camera positioned on a cliff overlooking the hyrophone locations. This dissertation is divided into four analysis chapters. In Chapter 3, discriminant analysis was used to validate the four N04 call subtypes which were originally parsed due to variations in slope segments. The first two functions of the discriminant analysis explained 97% of the variability. Most of the variability for the N04 call was found in the front convex and the terminal portions of the call, while very little variability was found in the center region of the call. This research revealed that individual killer whales produced multiple subtypes of the N04 call. No correlations of behaviors to acoustic parameters obtained were found. The aim of the Chapter 4 was to determine if killer whale calling behavior varied prior to and after the animals had joined. Pulsed call rates were found to be greater pre- compared to post-joining events. Two-way vocal exchanges were more common occurring 74% of the time during pre-joining events. In Chapter 5, initiated and first response to calls varied between age/sex class groups when mothers were separated from an offspring. Solo mothers and calves initiated pulsed calls more often than they responded. Most of the no vocal responses were due to mothers who were foraging. Finally, observations of the frequency split in N04

  4. LEGO: A Modular Approach to Accelerator Alignment Data Analysis

    Energy Technology Data Exchange (ETDEWEB)

    LeCocq, Catherine M

    2003-05-14

    The underlying unity of the numerous surveying computational methods is hidden by many practical differences in data acquisition. Traditional programming languages have added to the confusion by requiring programmers to describe the numeric data in very concrete and low-level structures (mostly arrays). In fact the algorithms behind all coordinate determination from surveying observations come down to basic methods of linear algebra. Lego uses the paradigm of object oriented programming (OOP) to more closely model the fundamental mathematical structures of all geodetic methods. Once the methods are in OOP form, the commonality across them becomes more obvious and a general architecture for a wide range of geodetic treatments becomes possible. This paper describes the fundamental concepts of this architecture and its advantages in terms of clarity (maintainability, testability and multi-author), portability and extensibility (observation types, resolution techniques and storage methods). The very first version of Lego was built in 1994 as a set of C routines to be used for the adjustment of theodolite data and tracker data. The routines were organized into six modules. Each module answered a specific task. The tasks had been identified as followed: general implementation, input, generic surveying formulas, statistical functions, matrix manipulation and specific resolution technique. This organization was the reason for the name Lego, but more seriously the purpose of this separation was to make Lego easily adaptable to any environment and easily expandable to new resolution techniques. At a second look, it was also a cry for being converted into a more modern language. Because C++ is primarily a superset of C, most C++ compilers have no problems compiling regular C code and may also handle a mixture of C and C++. This made the transformation of Lego very fast and painless. Up to now Lego is still using C functions for file access and dynamic memory allocation but is

  5. Graeco-Roman Astro-Architecture: The Temples of Pompeii

    Science.gov (United States)

    Tiede, Vance R.

    2014-01-01

    Roman architect Marcus Vetruvius Pollio (ca. 75-15 BC) wrote, “[O]ne who professes himself as an architect should be…acquainted with astronomy and the theory of the heavens…. From astronomy we find the east, west, south, and north, as well as the theory of the heavens, the Equinox, Solstice and courses of the Stars.” (De Architectura Libri Decem I:i:3,10). In order to investigate the role of astronomy in temple orientation, the author conducted a preliminary GIS DEM/Satellite Imaging survey of 11 temples at Pompeii, Italy (N 40d 45', E 14d 29'). The GIS survey measured the true azimuth and horizon altitude of each temple’s major axis and was field checked by a Ground Truth survey with theodolite and GPS, 5-18 April 2013. The resulting 3D vector data was analyzed with Program STONEHENGE (Hawkins 1983, 328) to identify the local skyline declinations aligned with the temple major axes. Analysis suggests that the major axes of the temples of Apollo, Jupiter and Venus are equally as likely to have been oriented to Pompeii’s urban grid, itself oriented NW-SE on Mt. Vesuvius’ slope and hydraulic gradient to optimize urban sewer/street drainage (cf. Hodge 1992). However, the remaining nine temples appear to be oriented to astronomical targets on the local horizon associated with Graeco-Roman calendrics and mythology. TEMPLE/ DATE/ MAJOR AXIS ASTRO-TARGET (Skyline Declination in degrees) Public Lares/AD 50/ Cross-Quarter 7 Nov/3 Feb Sun Set, Last Gleam (-16.5) Vespsian/ AD 69-79/ Cross-Quarter 7 Nov/3 Feb Sun Set, LG (-16.2) Fortuna Augusta/ AD 1/ Winter Solstice Sun Set, LG (-22.9) Aesculapius/ 100 BC/ Perseus Rise (β Persei-Algol = +33.0) & Midsummer Moon Major Stand Still Set, LG (-28.1) Isis/ 100 BC/ Midwinter Moon Major Stand Still Rise, Tangent (+28.5) & Equinox Sun Set, Tangent (-0.3) Jupiter/ 150 BC/ Θ Scorpionis-Sargas Rise (-38.0) Apollo/ 550 (rebuilt 70 BC)/ α Columbae-Phact Rise (-37.1) Venus/ 150 BC (rebuilt 70 BC)/ α Columbae-Phact Rise (-37

  6. LEGO: A Modular Approach to Accelerator Alignment Data Analysis

    International Nuclear Information System (INIS)

    LeCocq, Catherine M

    2003-01-01

    The underlying unity of the numerous surveying computational methods is hidden by many practical differences in data acquisition. Traditional programming languages have added to the confusion by requiring programmers to describe the numeric data in very concrete and low-level structures (mostly arrays). In fact the algorithms behind all coordinate determination from surveying observations come down to basic methods of linear algebra. Lego uses the paradigm of object oriented programming (OOP) to more closely model the fundamental mathematical structures of all geodetic methods. Once the methods are in OOP form, the commonality across them becomes more obvious and a general architecture for a wide range of geodetic treatments becomes possible. This paper describes the fundamental concepts of this architecture and its advantages in terms of clarity (maintainability, testability and multi-author), portability and extensibility (observation types, resolution techniques and storage methods). The very first version of Lego was built in 1994 as a set of C routines to be used for the adjustment of theodolite data and tracker data. The routines were organized into six modules. Each module answered a specific task. The tasks had been identified as followed: general implementation, input, generic surveying formulas, statistical functions, matrix manipulation and specific resolution technique. This organization was the reason for the name Lego, but more seriously the purpose of this separation was to make Lego easily adaptable to any environment and easily expandable to new resolution techniques. At a second look, it was also a cry for being converted into a more modern language. Because C++ is primarily a superset of C, most C++ compilers have no problems compiling regular C code and may also handle a mixture of C and C++. This made the transformation of Lego very fast and painless. Up to now Lego is still using C functions for file access and dynamic memory allocation but is

  7. A Comparison of Four Different Beach Profiling Techniques at St Leonards, Victoria - An Example of a Collaborative Stakeholder Research Project

    Science.gov (United States)

    Cox, N. L.; Miner, A. S.; Wynn, N.; Turner, D.

    2015-12-01

    Many beaches in Australia are under attack from shoreline erosion due rising sea levels and the action of waves. St Leonard's beach, a tourist town on the Victorian coastline, is of concern from this destructive erosion and the threat to the economic stability of the town. The major cause of erosion in this area is related to waves created from strong to gale force north to north-easterly winds. This in turn produces a northerly longshore current along with sediment suspension leading to a negative sediment budget. Ongoing and systematic monitoring of the shoreline movement is important to ensure the coast is understood and effectively managed now and into the future. Coastal land managers and agencies are required to find 'cost-effective' and 'fit-for-purpose' coastal monitoring methodologies which are affordable and efficient. This project forges a collaboration of stakeholders from academia, public sector land manager, local government and the private sector to compare four different methods of obtaining beach profiles. The four methods of obtaining beach profiles used for comparison are: 1. traditional survey method along transects using a total station theodolite, 2. traditional survey method along transects using a builder's grade laser level, 3. a small multi-rotor unmanned aerial vehicle (UAV) to produce a full 3D digital surface model of the study area, and 4. an experimental stationary device to produce a limited 3D model along a designated transect using terrestrial photogrammetric approach via a small GPS enabled camera. Assessment is made by comparing the method's precision, spatial coverage, expertise and equipment requirements/costs, preparation time, field acquisition time, number of people required in the field, post-acquisition processing time, and applicability for community use. Whilst is must be very clearly stated that all methods proved to be successful, the preliminary results of the "workflow and resourcing" assessment ranked the methods in

  8. NASA Tech Briefs, January 2012

    Science.gov (United States)

    2012-01-01

    Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34

  9. Testing the effectiveness of an acoustic deterrent for gray whales along the Oregon coast

    Energy Technology Data Exchange (ETDEWEB)

    Lagerquist, Barbara [Oregon State University Marine Mammal Institute; Winsor, Martha [Oregon State University Marine Mammal Institute; Mate, Bruce [Oregon State University Marine Mammal Institute

    2012-12-31

    This study was conducted to determine whether a low-powered sound source could be effective at deterring gray whales from areas that may prove harmful to them. With increased interest in the development of marine renewal energy along the Oregon coast the concern that such development may pose a collision or entanglement risk for gray whales. A successful acoustic deterrent could act as a mitigation tool to prevent harm to whales from such risks. In this study, an acoustic device was moored on the seafloor in the pathway of migrating gray whales off Yaquina Head on the central Oregon coast. Shore-based observers tracked whales with a theodolite (surveyor’s tool) to accurately locate whales as they passed the headland. Individual locations of different whales/whale groups as well as tracklines of the same whale/whale groups were obtained and compared between times with the acoustic device was transmitting and when it was off. Observations were conducted on 51 d between January 1 and April 15, 2012. A total of 143 individual whale locations were collected for a total of 243 whales, as well as 57 tracklines for a total of 142 whales. Inclement weather and equipment problems resulted in very small sample sizes, especially during experimental periods, when the device was transmitting. Because of this, the results of this study were inconclusive. We feel that another season of field testing is warranted to successfully test the effectiveness of the deterrent, but recommend increasing the zone of influence to 3 km to ensure the collection of adequate sample sizes. Steps have been taken to acquire the necessary federal research permit modification to authorize the increased zone of influence and to modify the acoustic device for the increased power. With these changes we are confident we will be able to determine whether the deterrent is effective at deflecting gray whales. A successful deterrent device may serve as a valuable mitigation tool to protect gray whales, and

  10. THE ROLE OF ASTRO-GEODETIC IN PRECISE GUIDANCE OF LONG TUNNELS

    Directory of Open Access Journals (Sweden)

    M. Mirghasempour

    2015-12-01

    Full Text Available One of prime aspects of surveying projects is guidance of paths of a long tunnel from different directions and finally ending all paths in a specific place. This kind of underground surveying, because of particular condition, has some different points in relation to the ground surveying, including Improper geometry in underground transverse, low precise measurement in direction and length due to condition such as refraction, distinct gravity between underground point and corresponding point on the ground (both value and direction of gravity and etc. To solve this problems, astro-geodetic that is part of geodesy science, can help surveying engineers. In this article, the role of astronomy is defined in two subjects: 1- Azimuth determination of directions from entrance and exit nets of tunnel and also calibration of gyro-theodolite to use them in Underground transvers: By astronomical methods, azimuth of directions can be determine with an accuracy of 0.5 arcsecond, whereas, nowadays, no gyroscope can measure the azimuth in this accuracy; For instance, accuracy of the most precise gyroscope (Gyromat 5000 is 1.2 cm over a distance of one kilometre (2.4 arcsecond. Furthermore, the calibration methods that will be mention in this article, have significance effects on underground transverse. 2- Height relation between entrance point and exit point is problematic and time consuming; For example, in a 3 km long tunnel ( in Arak- Khoram Abad freeway, to relate entrance point to exit point, it is necessary to perform levelling about 90 km. Other example of this boring and time consuming levelling is in Kerman tunnel. This tunnel is 36 km length, but to transfer the entrance point height to exit point, 150 km levelling is needed. According to this paper, The solution for this difficulty is application of astro-geodetic and determination of vertical deflection by digital zenith camera system TZK2-D. These two elements make possible to define geoid profile

  11. Comparative morphological analysis of cherry tomato fruits from three cropping systems Análise morfológica comparativa de frutos tomate cereja provenientes de três sistemas de cultivo

    Directory of Open Access Journals (Sweden)

    Sônia Cachoeira Stertz

    2005-06-01

    Full Text Available Attempts to meet produces market demand are not always followed by research reports showing the impact of novel, intensive cropping systems on the environment, human and animal health, and eventual chemical and structural changes of plants. This work carries a comparative evaluation of the morphology and anatomy of cherry tomato fruits obtained from organic, conventional and hydroponic cropping systems. Fruits were collected at the free market in the greater Curitiba, Paraná, Brazil. For each culture method, 50 fruits their weight, diameter and volume measured. For the anatomical analysis, samples of the pericarp of ten fruits were excised and embedded in glycol methacrylate; 6-mm cuts were then obtained, stained with toluidine blue, and mounted on permanent glass slides. The anatomical analysis and illustrations were performed in Olympus and Zeiss photonic microscope. Samples obtained from the organic cropping system presented the highest mass, diameter, volume and density. The pericarp of fruits, obtained from the conventional cropping system presented larger but less abundant cells in comparison to the pericarp of the hydroponic and organic-produced fruits.A ciência agrícola buscou novas formas de cultivo para atender às exigências de mercado e dividiu-se em três grandes vertentes: os sistemas de cultivo orgânico, convencional e hidropônico. Todavia, esses avanços nem sempre foram acompanhados por pesquisas que objetivassem apontar o impacto de uma nova técnica agrícola sobre o ambiente, a saúde humana e animal e aos próprios vegetais em seus aspectos químicos e estruturais. Este trabalho tem por objetivo o estudo comparativo da morfo-anatomia do fruto do Lycopersicon esculentum var. cerasiforme (Duval A. Gray, cultivado nos sistemas orgânico, convencional e hidropônico. Os frutos foram coletados no comércio varejista da Região Metropolitana de Curitiba, Paraná, Brasil. Para cada cultivo foram analisados 50 frutos. Cada

  12. Remodeling of adipose tissue at experimental diabetes mellitus

    Directory of Open Access Journals (Sweden)

    O. A. Konovalova

    2013-08-01

    Full Text Available Introduction Diabetes mellitus (DM type 1 is chronіc disease whith progressive selective destruction of β- cells pancreatic islets (of Langerhans and whith development of absolute insulin failure. Active immune mechanisms take part in pathogenesis of this disease. Recently many publication appeared which report about the role of adipose tissue. In such way adipose tissue is not only the main metabolic regulator and endocrine organ synthesizing more than 30 regulatory proteins- adipokines, but it is one of the organs of immune system. Dysregulation of adipose tissue leads to morphological restructuring- remodeling of adipocytes, and the development of inflammation of adipose tissue in its turn is integral component of progression of many diseases. The aim of research The aim of this study was to investigate the morphological and functional state of parapancreatic fibre adipocytes in male Wistar rats in experimental diabetes mellitus. Materials and methods The study has been carried out on 20 male Wistar rats with weight 115-135 g. The animals were divided into 2 groups. The control group, which were injected 0,5 ml 0,1 М citrate buffer intraperitoneally (1group. Rats with 7 day experimental streptozotocin-induced diabetes mellitus were in the 2nd group. Adipose tissue was examined on the seventh day. For histological examination sections were colored with haematoxylin and eosin. Images were taken by using a fluorescence microscope PrimoStar(ZEISS,Germany with a computer-assisted video system AxioCam 5c (ZEISS,Germany including the NIH-Image software (NIH Image version 1·46. All statistical analyses were performed using EXCEL MS Office 2010 (Microsoft Corp., USA, STATISTICA 6.0 (Stat-Soft, 2001 software. Results were expressed as mean values ± SEM. Differences were considered statistically significant if the p value was <0.05. Results Injection of streptozotocin to experimental animals led to the development of experimental diabetes mellitus

  13. Reimplante mediato de dentes tratados ou não com solução de hipoclorito de sódio a 1% - estudo histomorfométrico em ratos Effects of sodium hypochlorite on periodontal healing after tooth replantation - histomorphometric study in rats

    Directory of Open Access Journals (Sweden)

    Cláudia Misue KANNO

    2000-06-01

    Full Text Available Foi avaliada a influência do hipoclorito de sódio a 1% no reparo do periodonto de incisivos reimplantados tardiamente em ratos. Os dentes foram mantidos em meio ambiente durante 30 minutos e a seguir imersos em hipoclorito de sódio a 1%, por 25 minutos. Os animais foram sacrificados aos 10, 30 ou 60 dias. Os cortes histológicos foram obtidos no sentido transversal dos terços cervical, médio e apical e delineados com um aumento de 52 vezes. Os eventos observados sobre a superfície radicular foram medidos quanto a sua extensão através de um sistema analisador de imagens (Mini-Mop, Carl Zeiss. Aos 10 dias, observou-se a predominância de tecido conjuntivo fibroso no grupo tratado. Aos 30 e 60 dias observou-se o aumento da anquilose e reabsorção por substituição, assim como neoformação limitada de ligamento periodontal. No grupo controle, aos 30 e 60 dias, foram observadas áreas de reabsorções mais extensas e profundas, quando comparadas ao grupo tratado. Os resultados possibilitaram as seguintes conclusões quando comparado o grupo tratado com o controle: a leva à formação de tecido conjuntivo semelhante a uma cápsula fibrosa no período inicial do reparo; b possibilita uma limitada neoformação de ligamento periodontal; c ocasiona uma superfície de anquilose mais extensa; d não impede a reabsorção por substituição.The aim of the present study was to examine the influence of 1% sodium hypochlorite on periodontal healing after tooth replantation. Rats incisors were extracted, maintained in the environment during 30 minutes, then immersed in 1% sodium hypochlorite for 30 minutes. In the control group, the teeth were maintained in distilled water. The animals were sacrificed after 10, 30 and 60 days. Transversal slices of the teeth were obtained and histologically processed through the hematoxylin and eosin technique. Slices from the cervical, middle and apical thirds of each tooth were selected for the analysis. The

  14. Evaluación del equipo de interferometría óptica de coherencia parcial Lenstar en la biometría ocular Evaluation of Lenstar partial coherente optical interferometry device in the ocular biometry

    Directory of Open Access Journals (Sweden)

    Iramis Miranda Hernández

    2010-01-01

    Full Text Available OBJETIVOS: Comparar y evaluar la biometría ocular con el nuevo equipo de interferometría óptica de coherencia parcial (Lenstar con el equipo de interferometría óptica de baja coherencia IOL Master y también con los sistemas topográficos Galilei y Pentacam. MÉTODOS: Se realizó un estudio descriptivo, transversal, en 120 ojos de 60 pacientes. Para el cálculo del lente intraocular se tomaron mediciones con un nuevo biómetro Lenstar LS 900 (Haag Streit AG y con el IOL Master V.5 (Carl Zeiss Meditec AG. Se compararon mediante el análisis de regresión lineal y correlación de Pearson. También se compararon las medidas con las obtenidas por los equipos topógrafos Galilei y Pentacam. RESULTADOS: Existe una alta correspondencia en los valores biómetricos de longitud axial, queratometría y profundidad de la cámara anterior entre los equipos Lenstar e IOL Master. También se encontró una buena correspondencia entre las medidas de profundidad de cámara posterior y queratometría entre Lenstar y los topógrafos Galilei y Pentacam. CONCLUSIONES: El nuevo biómetro Lenstar, provee resultados que se correlacionan muy bien con aquellos obtenidos con los equipos IOL Master, Pentacam y Galilei. El equipo Lenstar es un equipo preciso que brinda información adicional por lo que es útil en la cirugía de catarata y la cirugía refractiva.OBJECTIVES: To compare and to evaluate the ocular biometry taken by a new optical partial coherence interferometry device (Lenstar,the low coherence optical interferometry equipment (ILO Master and the topographic systems Pentacam y Galilei. METHODS: A descriptive cross-sectional study was conducted in 120 eyes from 60 patients. For the IOL calculation, the necessary measurements were taken with the new optical biometer Lenstar LS 900 (Haig Streit AG and with the IOL Master V5 (Carl Zeiss Meditec AG. The results were evaluated using the linear regression analysis and Pearson´s correlation. The measures were

  15. A relação entre o comprimento dos processos ciliares medidos pela biomicroscopia ultra-sônica e a duração, localização e gravidade das uveítes The relationship between the length of ciliary processes as measured by ultrasound biomicroscopy and the duration, localization and severity of uveitis

    Directory of Open Access Journals (Sweden)

    Daniella Socci da Costa

    2006-06-01

    Full Text Available OBJETIVO: Determinar a relação entre o comprimento dos processos ciliares com a duração, localização e gravidade das uveítes. MÉTODOS: Foram analisados em estudo prospectivo, 58 indivíduos, incluindo pacientes com diferentes estágios de uveíte e indivíduos sem a doença (112 olhos, sendo 18 normais, no período de agosto de 2001 a agosto de 2002, no Departamento de Uveítes do Cole Eye Institute da Cleveland Clinic Foundation - Ohio - EUA. Todos os pacientes foram referidos para o exame de biomicroscopia ultra-sônica, pelo Departamento de Uveítes após exame oftalmológico de rotina. O aparelho modelo 840 (Zeiss-Humphrey com transdutor de 50 MHz foi utilizado para análise dos processos ciliares sob anestesia tópica e técnica de imersão. RESULTADOS: Em relação à etiologia das uveítes, a de maior freqüência foi a idiopática (27,8%. As uveítes recorrentes, agressivas e difusas levaram ao significante dano nos processos ciliares. A maior perda significativa na medida dos processos ciliares foi encontrada no quadrante inferior e as maiores medidas foram encontradas em olhos normais e no quadrante temporal. CONCLUSÃO: A biomicroscopia ultra-sônica mostrou ser método útil para avaliar as alterações anatômicas encontradas nos processos ciliares dos pacientes com uveíte. De acordo com estes achados, podemos criar recomendações para futuros trabalhos, que nos ajudem a avaliar a necessidade destes pacientes vir a receber tratamento mais agressivo em qualquer sinal de inflamação, com o objetivo de prevenir futuro dano e eventual hipotonia.PURPOSE: To determine the relationship between the length of ciliary processes as measured by ultrasound biomicroscopy and the duration, localization and severity of uveitis. METHODS: We analyzed in this prospective study, 58 individuals including patients with different stages of uveitis and normal patients (112 eyes including 18 normal, between August 2001 and August 2002, at the

  16. Chronic effect of vagotomy in the morphometry of the myenteric plexus of rats' duodenum Efeito crônico da vagotomia sobre a morfometria do plexo mioentérico do duodeno de ratos

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Martins-Júnior

    2010-09-01

    Full Text Available BACKGROUND: The gastrointestinal disorders have been associated with morphological alterations in the myenteric nervous plexus. AIM: To evaluate, through morphometric studies, the chronic effects of the subdiaphragmatic trunk vagotomy on the nervous plexus. METHODS: Fifteen male exemplars of Wistar Rattus novergicus weighing about 150g, distributed into three groups, have been used: control (n=5, Sham (n=5 and vagotomized (n=5. The animals were sacrificed after 30 and 90 days post surgery. Fragments of duodenum were fixed in Bouin solution, embedded into paraffin and stained with HE and PAS. Morphometric analysis was performed by a Carl Zeiss KM 450 image system. The following aspects were observed: the density of nervous cells per linear micrometer (µm (ND; the area of perikarya (µm² (NA; the number of satellite cells per µm (SCD; and the number of satellite cells per neuron (SC/N. The averages were compared with the help of "software" program Sigma Plus through two way - ANOVA and Tuckey post-test. RESULTS: Denervation increased SC/N (pRACIONAL: As disfunções gastrintestinais têm sido associadas à alterações morfológicas no plexo nervoso mioentérico. OBJETIVO: Avaliar através do estudo morfométrico, os efeitos crônicos da vagotomia troncular subdiafragmática sobre esse plexo nervoso. MÉTODOS: Foram utilizados 15 exemplares machos de Rattus novergicus da variedade Wistar, com cerca de 150 g, distribuídos nos grupos controle (n=5, Sham (n=5 e vagotomizados (n=5. Os animais foram sacrificados depois de 30 e 90 dias após as operações. Em seguida, fragmentos do duodeno foram fixados em solução de Bouin, incluídos em parafina e corados por HE e PAS. A análise morfométrica foi realizada por meio do sistema de análise de imagem Carl Zeiss KM 450. Foram observados: a densidade de células nervosas por micrômetro linear (µm; a área dos pericários (µm²; o número de células satélites por µm; e o número de células sat

  17. Editorial: Trends in Nanotechnology (TNT2005)

    Science.gov (United States)

    Correia, Antonio; Serena, Pedro A.; José Saenz, Juan; Reifenberger, Ron; Ordejón, Pablo

    2006-05-01

    the successful consequence of a coordinated effort among several organising Institutions: PHANTOMS Foundation, Universidad Autónoma de Madrid, Consejo Superior de Investigaciones Científicas, Universidad Carlos III de Madrid, Universidad Complutense de Madrid, Universidad de Oviedo, Donostia International Physics Center, Nanomaterials Laboratory-NIMS, CEA/LETI and CEA/DSM/DFRMC, University of Purdue and Georgia Institute of Technology. In addition, we are indebted to the following institutions, companies and government agencies for their help and financial support: NASA, Air Force Office of Scientific Research, iNANO, NSERC/CRSNG (Nano Innovation Platform), Sociedad de Microscopía Española (SME), Wiley-VCH, Raith GmbH, The European Office of Aerospace Research and Development (EOARD), The Office of Naval Research International Field Office (ONRIFO), World Scientific and Imperial College Press, Ministerio de Educación y Ciencia, Parque Científico de Barcelona, Parque Científico de Madrid, Tyndall National institute, Nanoquanta, GDR-E Nano-E, Minatec, Dupont, Physica Status Solidi, Zeiss, Ayuntamiento de Oviedo, Gobierno de Principado de Asturias, Asturiana de Zinc, cajAstur, Aleastur, Aceralia-Grupo Arcelor, Saint-Gobain Cristaleria, Mediadores Asociados Asturianos and Inderscience Publishers.We would like also to thanks the following companies for their participation: NanoTec, Raith GmbH, Scientec, NT-MDT, Schaefer Techniques, Suss Microtec, Carl Zeiss, Biometa, Wiley-VCH, World Scientific and Imperial College Press and Atomic Force.We invite readers of this special issue to join us in Grenoble (France), where the next Trends in Nanotechnology 2006 edition will take place (http://www.tnt2006.org).

  18. Metodologia para observação da camada de cera em maçãs, utilizando microscopia eletrônica de varredura Methodology for observation of the wax layer in apples, using scanning electron microscopy

    Directory of Open Access Journals (Sweden)

    Luis Antônio Suita de Castro

    2002-12-01

    Full Text Available A estrutura mais superficial da epiderme dos frutos é constituída por fina camada de cera, responsável por mecanismos de proteção, principalmente relacionados à evapotranspiração e ao ataque de patógenos. A visualização de cera por microscopia eletrônica de varredura apresenta dificuldades no processamento da amostra, pois os métodos rotineiramente utilizados ocasionam sérios danos a esta camada ou, simplesmente, provocam sua eliminação devido ao processo de solubilização causado pelos reagentes utilizados. Alguns autores têm utilizado temperaturas baixas (-90ºC para o processamento de amostras. No Brasil, tentativas de observação de cera em maçãs, utilizando a microscopia eletrônica de varredura, têm sido realizadas; entretanto, os resultados não foram satisfatórios. No Laboratório de Microscopia Eletrônica da Embrapa Clima Temperado, foi adaptado um método simples e que tem apresentado bons resultados. Para este experimento, foram retiradas pequenas porções da casca de maçãs da região equatorial dos frutos. As amostras foram fixadas em lâminas histológicas, utilizando fita adesiva nas extremidades. Posteriormente, foram colocadas em dessecador contendo sílica gel, para que ocorresse a desidratação. Após 72 horas, foram retirados fragmentos para fixação em stubs e metalização com ouro. Foi usado um microscópio eletrônico ZEISS (DSM-940A, regulado à distância de trabalho de 15mm, voltagem de aceleração de 10 kV e ampliação de 3.000 X. As imagens obtidas permitiram avaliar a interferência dos fatores ambientais utilizados no processo de frigoconservação de maçãs.The fruit epidermis is covered by a thin layer of wax which gives protection to the fruit, mainly against water loss and pathogenic organisms. Several studies using scanning electron microscope have been developed to study that wax. The wax layer visualization through the scanning microscope is difficult due to some problems of

  19. Avaliação da resistência adesiva e do padrão de descolagem de diferentes sistemas de colagem de braquetes associados à clorexidina Evaluation of the bond strength and debonding pattern of different bracket bonding systems associated with chlorhexidine

    Directory of Open Access Journals (Sweden)

    Jorge Luís de Oliveira Ribeiro

    2008-08-01

    Full Text Available OBJETIVOS: o objetivo deste estudo in vitro foi avaliar a resistência adesiva e o padrão de descolagem de diferentes sistemas de colagem de braquetes (Sistema Transbond XT / 3M-Unitek e Sistema Enlight / Ormco cujos respectivos adesivos foram pré-misturados ao verniz de clorexidina (Cervitec / Ivoclar-Vivadent. METODOLOGIA: a amostra utilizada foi constituída por 60 pré-molares humanos, extraídos por indicações ortodônticas, incluídos em cilindros de PVC e divididos aleatoriamente em quatro grupos: grupo 1 - Sistema Transbond XT conforme prescrito pelo fabricante; grupo 2 - Sistema Transbond XT associado a verniz de clorexidina; grupo 3 - Sistema Enlight conforme prescrito pelo fabricante; grupo 4 - Sistema Enlight associado a verniz de clorexidina. A resistência adesiva foi avaliada pelo teste de cisalhamento na máquina de ensaios universal EMIC (0,5mm/min; o padrão de descolagem foi avaliado, através da lupa estereoscópica STEMI 2000-C / Zeiss (20x, pela observação do Índice de Adesivo Remanescente (IAR na superfície do esmalte dentário, após a descolagem dos braquetes. RESULTADOS: não houve diferença estatisticamente significante (p AIM: The objective of this in vitro study was to evaluate the bond strength and the debonding pattern of different bracket bonding systems (Transbond XT System / 3M-Unitek and Enlight System / Ormco whose respective adhesives were pre-mixed with chlorhexidine varnish (Cervitec / Ivoclar-Vivadent. METHODS: The sample used consisted of sixty human pre-molars extracted for orthodontic purposes, included in PVC cylinder and randomly divided in four experimental groups: group 1 - Transbond XT System according to the manufacturer’s instructions; group 2 - Transbond XT System combined with chlorhexidine varnish; group 3 - Enlight System according to the manufacturer’s instructions; group 4 - Enlight System combined with chlorhexidine varnish. The bond strength evaluation was obtained through

  20. Aspectos morfológicos da uretra de ratas após eletroestimulação do assoalho pélvico Morphological aspects of the urethra in female rats after electrical stimulation of the pelvic floor

    Directory of Open Access Journals (Sweden)

    Adriana Luciana Moreno Camargo

    2013-04-01

    Full Text Available OBJETIVO: Avaliar os efeitos da eletroestimulação (ES do assoalho pélvico na uretra de ratas. MÉTODOS: Quarenta ratas adultas foram distribuídas, randomicamente, em quatro grupos com dez animais cada: Ctrl - sem intervenção; Sham - não foi submetido a ES, recebeu um eletrodo dentro da vagina; Exp6 - submetido a seis sessões de ES do assoalho pélvico; e Exp12 - submetido a 12 sessões de ES do assoalho pélvico. Ao final do experimento, todos os animais foram anestesiados, e o terço médio da uretra foi retirado, fixado em líquido de Bouin e processado para estudo histomorfométrico. Alguns cortes foram corados pela hematoxilina e eosina, para descrição morfológica e morfométrica, e outros, pelo picrosirius red, para avaliação do colágeno total. As espessuras da camada muscular e do epitélio foram obtidas, nos 4 quadrantes da uretra, pela realização de 20 medições em cada animal. O número de vasos sanguíneos presentes na lâmina própria foi obtido nos quatro quadrantes, em uma área de 10³ mm² por quadrante, sendo as imagens obtidas pelo programa de análise de imagens AxioVision® REL 4.3 (Carl Zeiss. A proporção de colágeno e de fibras musculares foi obtida de duas imagens por quadrante, de cada lâmina da uretra corada pelo picrosirius red, com auxílio do programa Imagelab®. Os dados foram submetidos à análise de variância (ANOVA e ao teste de comparações múltiplas de Tukey-Kramer (pExp6==Ctrl==Sham; *pPURPOSE: To evaluate the effects of electrical stimulation (ES of the pelvic floor on the urethra of female rats. METHODS: Forty adult rats were divided at random into four groups of ten animals each: Ctrl - without intervention; Sham - not submitted to ES, but with an electrode inserted into the vagina; Exp6 - submitted to six sessions of ES of the pelvic floor, and Exp12 - submitted to 12 sessions of ES of the pelvic floor. At the end of the experiment, all animals were anesthetized and the middle third

  1. Avaliação qualitativa do efeito de agentes de limpeza na camada de lama dentinária: estudo ultra-estrutural em microscopia eletrônica de varredura Smear layer removal: a qualitative scanning electron microscopy study

    Directory of Open Access Journals (Sweden)

    Maria Auxiliadora Junho de ARAÚJO

    1998-04-01

    Full Text Available Quando qualquer instrumento abrasiona ou corta a dentina, produz na superfície uma camada de lama dentinária ou "smear layer". Dependendo do agente de união indicado em Odontologia adesiva, há a necessidade ou não da remoção da camada de lama da superfície dentinária. Com a finalidade de verificar a ação de diferentes substâncias para a limpeza dentinária, utilizamos 20 dentes pré-molares superiores íntegros, mantidos em soro fisiológico, nos quais as coroas foram seccionadas ao meio no sentido mésio-distal. Com instrumento diamantado, removeu-se o esmalte da porção vestibular e da porção lingual da coroa e, com uma broca carbide cilíndrica lisa nº 56, cortou-se aproximadamente 1 mm de dentina com alta rotação sob abundante refrigeração ar/água, para produzir a camada de lama dentinária. Em seguida, essa superfície foi tratada com diferentes substâncias e lavada por 30 segundos com "spray" ar/água. No controle, foi simplesmente utilizado o "spray" ar/água. Os espécimes foram montados em suportes metálicos, preparados e visualizados no MEV-DSM 950 da Zeiss, em aumentos que variaram de 100 a 5.000 vezes. Os materiais que mais removeram a camada de lama foram, em ordem crescente: 1. "spray" ar/água; 2. fluoreto de sódio 2%; 3. associação alternada de Dakin/Tergensol; 4. água oxigenada 3%; 5. jateamento com óxido de alumínio 50 mm; 6. flúor acidulado 1,27%; 7. ácido poliacrílico 25%; 8. ácido fosfórico 10%.A smear layer is produced on the dentin surface after abrasion or cutting by instruments. Its removal is indicated or not according to the kind of bonding agent used in adhesive dentistry. The purpose of this study was to evaluate the possible effects of some substances on the smear layer. Twenty upper non-carious premolars, stored in isotonic saline solution, were mesiodistally hemi-sectioned and the buccal and lingual enamel was removed with high speed diamond bur. One millimeter of the dentinal

  2. Postmortem acinar autolysis in rat sublingual gland: a morphometric study.

    Science.gov (United States)

    Nery, Leticia Rodrigues; Moreira, Carla Ruffeil; Cestari, Tania Mary; Taga, Rumio; Damante, José Humberto

    2010-01-01

    To analyze and to quantify morphological acinar postmortem changes in rat sublingual glands (SLG). MATERIAL AND METHODSs: Fifty rats were divided into two groups of 25 animals each. Group I was used for morphological and morphometric evaluations and group II for the determination of gland density and processed gland volume. Acinar autolytic changes were studied at 0 (control group), 3, 6, 12 and 24 h postmortem periods. The morphometric analysis of the volume density (Vv) and total volume (Vt) of intact (ia) and autolyzed (aa) acini was performed under light microscopy using a Zeiss II integration grid with 100 symmetrically distributed points. Morphologically, temporal progressive nuclear alterations and gradual loss of the structural architecture of acinar cells were found. Regarding quantitative results, both the Vvaa and the Vvia showed statistically significant differences among all postmortem periods (p0.05), respectively. Vtaa increased from 0.18 mm³ at 0 h to 38.17 mm³ at 12 h, while Vtia showed a decrease from 33.47 mm³ to 0 mm³ between 3-24 h postmortem. Data concerning Vtaa were adjusted by two-variable linear regression, obtaining the equation: y=-3.54+3.38x (r²=0.90). The Vtaa growth rate calculated by this equation was 3.38 mm³/h between 0-12 h. Acinar autolysis on rat SLG demonstrated the most significant signs during the first 6 h postmortem and was widely spread through the gland at 12 h.

  3. In-die photomask registration and overlay metrology with PROVE using 2D correlation methods

    Science.gov (United States)

    Seidel, D.; Arnz, M.; Beyer, D.

    2011-11-01

    According to the ITRS roadmap, semiconductor industry drives the 193nm lithography to its limits, using techniques like double exposure, double patterning, mask-source optimization and inverse lithography. For photomask metrology this translates to full in-die measurement capability for registration and critical dimension together with challenging specifications for repeatability and accuracy. Especially, overlay becomes more and more critical and must be ensured on every die. For this, Carl Zeiss SMS has developed the next generation photomask registration and overlay metrology tool PROVE® which serves the 32nm node and below and which is already well established in the market. PROVE® features highly stable hardware components for the stage and environmental control. To ensure in-die measurement capability, sophisticated image analysis methods based on 2D correlations have been developed. In this paper we demonstrate the in-die capability of PROVE® and present corresponding measurement results for shortterm and long-term measurements as well as the attainable accuracy for feature sizes down to 85nm using different illumination modes and mask types. Standard measurement methods based on threshold criteria are compared with the new 2D correlation methods to demonstrate the performance gain of the latter. In addition, mask-to-mask overlay results of typical box-in-frame structures down to 200nm feature size are presented. It is shown, that from overlay measurements a reproducibility budget can be derived that takes into account stage, image analysis and global effects like mask loading and environmental control. The parts of the budget are quantified from measurement results to identify critical error contributions and to focus on the corresponding improvement strategies.

  4. A retrospective comparison of efficacy and safety of 680 consecutive lasik treatments for high myopia performed with two generations of flying-spot excimer lasers.

    Science.gov (United States)

    Gazieva, Lola; Beer, Mette Hjuler; Nielsen, Kim; Hjortdal, Jesper

    2011-12-01

    To compare the visual refractive outcome and complication of laser in situ keratomileusis (LASIK) carried out with a Carl Zeiss-Meditec MEL-70 Excimer laser and a MEL-80 laser for treatment of high myopia. Journal records of 680 consecutive eyes that underwent LASIK with a Schwind Supratome microkeratome and a MEL-70 Excimer laser (Group A), or a Moria M2 microkeratome and a MEL-80 Excimer laser (Group B) were reviewed. Manifest refraction, uncorrected and best spectacle-corrected visual acuity (BSCVA), corneal topography and central corneal thickness (CCT) were recorded before and 3 months after treatment. Pre- and postoperative complications, visual and refractive outcome and frequency of retreatments were registered. Mean preoperative spherical equivalent refraction was -8.52 dioptres (-5.50- -18 dioptres), and the mean attempted laser correction was -8.02 dioptres (-5.50- -11 dioptres). Three months after LASIK, the average treatment error (difference between achieved and attempted correction) was 1.20 (SD=1.19) dioptres of under correction in Group A and 0.52 (SD=1.00) dioptres in Group B. Four eyes lost more than two lines of BSCVA (0.6%). In 110 eyes (16%), a re-LASIK procedure was performed to reduce remaining myopia after the primary procedure. Laser in situ keratomileusis treatment for high myopia can effectively reduce high degrees of myopia. Under correction was observed in both treatment groups but Group B has a slightly better predictability. Significant loss of BSCVA occurs infrequently after LASIK for even considerable grades of myopia (0.6% in each group). © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  5. Investigating the usefulness of a cluster-based trend analysis to detect visual field progression in patients with open-angle glaucoma.

    Science.gov (United States)

    Aoki, Shuichiro; Murata, Hiroshi; Fujino, Yuri; Matsuura, Masato; Miki, Atsuya; Tanito, Masaki; Mizoue, Shiro; Mori, Kazuhiko; Suzuki, Katsuyoshi; Yamashita, Takehiro; Kashiwagi, Kenji; Hirasawa, Kazunori; Shoji, Nobuyuki; Asaoka, Ryo

    2017-12-01

    To investigate the usefulness of the Octopus (Haag-Streit) EyeSuite's cluster trend analysis in glaucoma. Ten visual fields (VFs) with the Humphrey Field Analyzer (Carl Zeiss Meditec), spanning 7.7 years on average were obtained from 728 eyes of 475 primary open angle glaucoma patients. Mean total deviation (mTD) trend analysis and EyeSuite's cluster trend analysis were performed on various series of VFs (from 1st to 10th: VF1-10 to 6th to 10th: VF6-10). The results of the cluster-based trend analysis, based on different lengths of VF series, were compared against mTD trend analysis. Cluster-based trend analysis and mTD trend analysis results were significantly associated in all clusters and with all lengths of VF series. Between 21.2% and 45.9% (depending on VF series length and location) of clusters were deemed to progress when the mTD trend analysis suggested no progression. On the other hand, 4.8% of eyes were observed to progress using the mTD trend analysis when cluster trend analysis suggested no progression in any two (or more) clusters. Whole field trend analysis can miss local VF progression. Cluster trend analysis appears as robust as mTD trend analysis and useful to assess both sectorial and whole field progression. Cluster-based trend analyses, in particular the definition of two or more progressing cluster, may help clinicians to detect glaucomatous progression in a timelier manner than using a whole field trend analysis, without significantly compromising specificity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. The Equatorial Coordinates and B-Magnitudes of the Stars in the Southern Hemisphere Zones Based on the Digitized Astronegatives of FON Project at the Ulugh Beg Astronomical Institute

    Science.gov (United States)

    Yuldoshev, Q. X.; Muminov, M. M.; Ehgamberdiev, Sh. A.; Usmanov, O. U.; Relke, H.; Protsyuk, Yu. I.; Kovylianska, O. E.; Protsyuk, S. V.; Andruk, V. N.

    FON (Russian abbreviation of the Photographic Sky Survey) were carried out at 6 observatories. The Kitab Observatory (KO) of Ulugh Beg Astronomical Institute (UBAI) of the Uzbek Academy of Sciences (UzAS) was involved in this project from 1981 to 1996. For the observations the Double Astrograph of Zeiss (DAZ, D/F = 40/300, 69"/mm) was used. On the FON project about 2600 photographic plates were exposed. In October, 2015 digitization of these astroplates were started using EPSON Expression 10000XL flatbed scanner with the spatial resolution of 1200 dpi and completed in June, 2016. The first stage of the work is the processing of the 2000 photographic plates in zones of the southern hemisphere with the declination between 0 and -20 degrees. The 1704 plates have already been processed. The equatorial coordinates α, δ of stars and galaxies were determined in the system of the Tycho2 catalogue and the Bmagnitudes in the system of the photoelectric standards. UBAI UzAS, Tashkent (Uzbekistan), ASU, Andijan (Uzbekistan), WHO, Essen (Germany), RI NAO, Nikolaev (Ukraine), MAO NASU, Kyiv (Ukraine) have taken part in the processing of the digitized images. For the data reduction the MIDAS package and software, developed in the MAO NASU were used. Based on the results of the processing of the astronegatives in the sectors of right ascension from 0 hours to 24 hours and declination from - 20° to 0° the internal errors of the catalogue were estimated. The errors calculated for all stars are 0.17" and 0.18m respectively. For the stars brighter than 14 magnitude the errors are 0.08" and 0.07m for the equatorial coordinates and B-magnitudes respectively.

  7. Surface modified gold nanoparticles for SERS based detection of vulnerable plaque formations (Conference Presentation)

    Science.gov (United States)

    Matthäus, Christian; Dugandžić, Vera; Weber, Karina; Cialla-May, Dana; Popp, Jürgen

    2017-02-01

    Cardiovascular diseases are the leading cause of death worldwide. Atherosclerosis is closely related to the majority of these diseases, as a process of thickening and stiffening of the arterial walls through accumulation of lipids, which is a consequence of aging and life style. Atherosclerosis affects all people in some extent, but not all arterial plaques will necessarily lead to the complications, such as thrombosis, stroke and heart attack. One of the greatest challenges in the risk assessment of atherosclerotic depositions is the detection and recognition of plaques which are unstable and prone to rupture. These vulnerable plaques usually consist of a lipid core that attracts macrophages, a type of white blood cells that are responsible for the degradation of lipids. It has been hypothesized that the amount of macrophages relates to the overall plaque stability. As phagocytes, macrophages also act as recipients for nanoscale particles or structures. Administered gold nanoparticles are usually rabidly taken up by macrophages residing within arterial walls and can therefore be indirectly detected. A very sensitive strategy for probing gold nanoparticles is by utilizing surface enhanced Raman scattering (SERS). By modifying the surface of these particles with SERS active labels it is possible to generate highly specific signals that exhibit sensitivity comparable to fluorescence. SERS labeled gold nanoparticles have been synthesized and the uptake dynamics and efficiency on macrophages in cell cultures was investigated using Raman microscopic imaging. The results clearly show that nanoparticles are taken up by macrophages and support the potential of SERS spectroscopy for the detection of vulnerable plaques. Acknowledgements: Financial support from the Carl Zeiss Foundation is highly acknowledged. The project "Jenaer Biochip Initiative 2.0" (03IPT513Y) within the framework "InnoProfile Transfer - Unternehmen Region" is supported by the Federal Ministry of

  8. Sensitivity and specificity of machine learning classifiers for glaucoma diagnosis using Spectral Domain OCT and standard automated perimetry

    Directory of Open Access Journals (Sweden)

    Fabrício R. Silva

    2013-06-01

    Full Text Available PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs for glaucoma diagnosis using Spectral Domain OCT (SD-OCT and standard automated perimetry (SAP. METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP and retinal nerve fiber layer (RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California. Receiver operating characteristic (ROC curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG, Naive-Bayes (NB, Multilayer Perceptron (MLP, Radial Basis Function (RBF, Random Forest (RAN, Ensemble Selection (ENS, Classification Tree (CTREE, Ada Boost M1(ADA,Support Vector Machine Linear (SVML and Support Vector Machine Gaussian (SVMG. Areas under the receiver operating characteristic curves (aROC obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE to 0.946 (RAN.The best OCT+SAP aROC obtained with RAN (0.946 was significantly larger the best single OCT parameter (p<0.05, but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19. CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

  9. 23Na-MRI of recurrent glioblastoma multiforme after intraoperative radiotherapy: technical note

    International Nuclear Information System (INIS)

    Haneder, Stefan; Buesing, Karen A.; Schoenberg, Stefan O.; Ong, Melissa M.; Giordano, Frank A.; Wenz, Frederik; Konstandin, Simon; Schad, Lothar R.; Brehmer, Stefanie; Schmiedek, Peter

    2015-01-01

    We report the first case of an intraoperative radiotherapy (IORT) in a patient with recurrent glioblastoma multiforme (GBM) who was followed up with a novel magnetic resonance imaging (MRI) method - 23 Na-MRI - in comparison to a standard contrast-enhanced 1 H-MRI and 18 F-FET-PET. A 56-year-old female patient with diagnosed GBM in July 2012 underwent tumor resection, radiochemotherapy, and three cycles of chemotherapy. After a relapse, 6 months after the initial diagnosis, an IORT was recommended which was performed in March 2013 using the INTRABEAM system (Carl Zeiss Meditec AG, Germany) with a 3-cm applicator and a surface dose of 20 Gy. Early post-operative contrast-enhanced and 1-month follow-up 1 H-MRI and a 18 F-FET-PET were performed. In addition, an IRB-approved 23 Na-MRI was performed on a 3.0-T MR scanner (MAGNETOM TimTrio, Siemens Healthcare, Germany). After re-surgery and IORT in March 2013, only a faint contrast enhancement but considerable surrounding edema was visible at the medio-posterior resection margins. In April 2013, new and progressive contrast enhancement, edema, 23 Na content, and increased uptake in the 18 F-FET-PET were visible, indicating tumor recurrence. Increased sodium content within the area of contrast enhancement was found in the 23 Na-MRI, but also exceeding this area, very similar to the increased uptake depicted in the 18 F-FET-PET. The clearly delineable zone of edema in both examinations exhibits a lower 23 Na content compared to areas with suspected proliferating tumor tissue. 23 Na-MRI provided similar information in the suspicious area compared to 18 F-FET-PET, exceeding conventional 1 H-MRI. Still, 23 Na-MRI remains an investigational technique, which is worth to be further evaluated. (orig.)

  10. Comparison of radiological and morphologic assessments of myocardial bridges.

    Science.gov (United States)

    Ercakmak, Burcu; Bulut, Elif; Hayran, Mutlu; Kaymaz, Figen; Bilgin, Selma; Hazirolan, Tuncay; Bayramoglu, Alp; Erbil, Mine

    2015-09-01

    In this study we aimed to compare the findings of coronary dual-source computed tomography angiography of myocardial bridges with cadaveric dissections. Forty-one isolated, non-damaged fresh sheep hearts were used in this study. Myocardial bridges of the anterior interventricular branch of the left coronary artery were demonstrated and analyzed by a coronary dual-source computed tomography angiography. Dissections along the left anterior interventricular branch of the left coronary artery were performed by using Zeiss OPMI pico microscope and the length of the bridges were measured. The depths of the myocardial bridges were measured from the stained sections by using the light microscope (Leica DM 6000B). MBs were found in all 41 hearts (100%) during dissections. Dual-source computed tomography angiography successfully detected 87.8% (36 of the 41 hearts) of the myocardial bridges measured on left anterior interventricular branch of left coronary artery. The lengths of the myocardial bridges were found 5-40 and 8-50 mm with dissection and dual-source computed tomography angiography, respectively. And the depths were found 0.7-4.5 mm by dual-source computed tomography angiography and 0.745-4.632 mm morphologically. Comparison of the mean values of the lengths showed statistically significantly higher values (22.0 ± 8.5, 17.7 ± 7.7 mm, p = 0.003) for the dissections. Radiological assessment also effectively discriminated complete bridges from incomplete ones. Our study showed that coronary computed tomography angiography is reliable in evaluating the presence and depth of myocardial bridges.

  11. [Selective retina therapy in central serous chorioretinopathy with detachment of the pigmentary epithelium].

    Science.gov (United States)

    Klatt, C; Elsner, H; Pörksen, E; Brinkmann, R; Bunse, A; Birngruber, R; Roider, J

    2006-10-01

    Selective Retina Therapy (SRT) is a new and innovative laser treatment modality that selectively treats the retinal pigmentary epithelium while sparing the photoreceptors. This therapeutic concept appears to be particularly suitable for treating patients with acute or chronic central serous chorioretinopathy (CSC). We present preliminary results obtained in five patients who had CSC associated with pigmentary epithelium detachment (PED) and serous subretinal fluid (SRF) and who were treated with SRT. This case series was made up of five male patients (mean age 47 years) with chronic CSC and SRF resulting from PED. Examinations performed before and at 1 month and 3 months after the treatment were: BCVA, FLA, OCT (Zeiss OCT III). For SRT, confluent treatment of the PED (area of leakage) was carried out using a pulsed frequency-doubled, Q-switched Nd-YLF prototype laser (lambda=527 nm, t= 1.7 s, 100 Hz, energy = 150-250 J). Best corrected visual acuity at baseline was 0.53, while after 4 weeks it was 0.56 and after 12 weeks, 0.5. At baseline leakage was seen at the PED on fluorescein angiography in all patients. After 4 weeks leakage activity was no longer noted on angiography in 4 of 5 patients. OCT at baseline showed SRF at the edge of the PED in all patients, but in 4 of the 5 patients this was no longer detectable after 4 weeks. SRT is a safe and effective treatment for patients with CSC in which PED has caused SRF. Not a single case of rip syndrome was observed in this study, even though the PED was treated confluently. Since SRT spares the photoreceptors it is particularly suitable for the treatment of CSC, especially when the origin of leakage is located close to the fovea. The results indicate that SRT leads to reconstruction of the outer blood-retina barrier.

  12. Nupela species (Naviculales: Bacillariophyceae from Colombian lowland waters including N. acaciensis nov. sp. and N. catatumbensis nov. sp.

    Directory of Open Access Journals (Sweden)

    Silvia Sala

    2014-03-01

    Full Text Available The genus Nupela comprises ca. 50 species that generally have a distribution restricted by bioclimatic frontiers. As part of an integrated analysis of the diatom flora of Colombia, in this study we focused our interest on the genus Nupela from lowland waters. Periphyton samples were collected from 150 sites of lotic water bodies in Colombia, taking into account hidrogeomorfological variability. In each sampling station, periphyton samples were obtained by scraping, and temperature, pH, dissolved oxygen and conductivity variables were measured. Samples were processed by both light microscopy (LM; Carl Zeiss Axio Scope.A1 and scanning electron microscopy (SEM; FEI-Quanta 450 and a Jeol JSM-6360 LV. The genus Nupela was found in 28 sites. Five taxa were identified, described and illustrated from tropical or subtropical environments: N. lesothensis, N. praecipua y N. subpallavicinii; these were new records for Colombia, and N. acaciensis and N. catatumbensis two new species for science. N. acaciensis is characterized by raphe branches of both valves equally long combined with cymbelloid symmetry, striae built by 2 transapically elongated areolae that delimit a longitudinal line at each hemivalve. N. catatumbensis is characterized by the presence of a well developed raphe in both valves; valves lanceolate with subcapitated to capitated ends and cymbelloid symmetry, striae built by 3-4 transapically elongated areolae, interestriae elevated as transapical ribs and internal proximal raphe ends hook-shaped. The genus Nupela was widely distributed in the studied basins but showed different distribution patterns: N. acaciensis and N. subpallavicini had a restricted distribution, while N. catatumbensis, N. lesothensis and N. praecipua had a wider distribution, and were collected in sites with significant variations in their ecomorphology, altitude, temperature, pH and electrolyte content.

  13. Estimation of ocular volume from axial length.

    Science.gov (United States)

    Nagra, Manbir; Gilmartin, Bernard; Logan, Nicola S

    2014-12-01

    To determine which biometric parameters provide optimum predictive power for ocular volume. Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm(3)) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were -2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm(3)) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R(2) values of 79.4% for TOV. Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Design of the science-fold mirrors for the Gemini telescopes

    Science.gov (United States)

    Peschel, Thomas; Damm, Christoph; Heilemann, Wolfgang

    2000-07-01

    As a part of the Acquisition and Guidance Unit for the Gemini project a light-weight, 50 cm flat mirror has been designed at the Fraunhofer Institute for Applied Optics and Precision Mechanics in Jena as a subcontractor of the Carl Zeiss Jena company. A light-weight design of the mirror and its mount was essential since the total mass of the whole assembly including the positioning system was limited to 50 kg while interferometric quality of the mirror surface was required for arbitrary orientation. The overall surface error was below 54 nm r.m.s. while 27 nm was achieved in the central part. The mirror was fabricated from low-expansion glass ceramics to avoid thermally induced deformations. By milling pockets into its rear surface the mass of the mirror was reduced by 70%. The mirror is mounted cinematically via six solid-state hinges to three steel levers. The levers are connected to the mount frame at their centers via ball-and- sphere joints. This arrangement determines the position of the mirror uniquely while it allows for the thermal expansion of the mount frame. The position of the mirror as well as its tilt around an axis perpendicular to the optical one may be controlled a precision of 20 micrometers and 3 arcsec, respectively. The tilt axis is driven directly by two high- torque motors. To avoid an excessive power consumption of the motors the torque of the mirror head to be compensated for by a counterweight mechanism. The mirror may be deployed into the optical path using spindle driven linear rails.

  15. The micromachined logo of Atomki

    International Nuclear Information System (INIS)

    Rajta, I.; Szilasi, S.Z.

    2006-01-01

    Complete text of publication follows. Proton Beam Micromachining, also known as P-beam Writing, is a direct write 3- dimensional lithographic technique. Conventional resist types are PMMA (polymethylmethacrylate), and SU-8 (of MicroChem Corp.); they are positive and negative resists, respectively. In this work we used SU-8, the most common negative resist material. SU-8 was spun on a flat surface, typically Silicon or glass. A direct write proton beam was scanned over an arbitary structure (the Atomki logo can be replaced by any other structure), which produces chain scissioning in the polymer. Post exposure bake (PEB) is usually needed in case of conventional optical lithography, but using protons this bake is done in situ as the ions heat up the sample in vacuum. Subsequently chemical etching takes place, the solvent is available at MicroChem Corp. The schematic diagram of the above described micromachining process is shown on Fig. 1. The irradiation requires a scanning proton microbeam system equipped with suitable beam scanning and blanking facilities. This is available in the Institute, our setup has been upgraded from doublet to triplet focusing system (Oxford Microbeams Ltd.). For scanning we use a DIO card (PCI-6731 of National Instruments), and the IonScan software [1]. Sample preparation was carried out at our 'semi clean' room. This is also where chemical development of the samples and the optical microscopy have been done too. A Zeiss Axio Imager microscope is available (equipped with 5 objective lenses, 4 different contrast methods, transmitted or reflected light illumination). Fig. 2. shows a typical example of the Atomki logo. This is a bright field image, a number of different nice and colourful images can be produced with the other contrast techniques (for more images see the Institute website: http://www.atomki.hu/ ). (author)

  16. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    Science.gov (United States)

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  17. Efficiency analysis of orthokeratological correction in the treatment of progressive myopia in childhood

    Directory of Open Access Journals (Sweden)

    Dolgova Е.А.

    2017-06-01

    Full Text Available Objective: to evaluate the effectiveness of orthokeratological correction in the treatment of progressive myopia in children. Material and methods. A retrospective study correction of myopia orthokeratology lenses of 100 patients (178 eyes with an established diagnosis of myopia of an average degree, undergoing treatment at the Clinic of eye diseases of SSMU. Group I consisted of 50 patients who received OK-correction lenses "Emerald" by Euclid Systems Corporation (USA. The wear time is 2 years. Group II included 50 people (87 eyes, using spectacle correction during the same time. Patients underwent visual acuity testing, biomicroscopy, refractometry, determination of reserves of accommodation, ultrasonic biometry (IOL-Master, CarlZeiss is a measurement of the size of the front-sadayoshi eyeball, survey after 2 years of using the selected correction. Results. Comparative analysis showed that the use of OK lenses for patients with myopia of an average degree resulted in a significant reduction in the rate of progression of myopia. In the background wearing OK lenses for 2 years has been the increase PZO, PZO dynamics were 0.09±0.05 mm. For the correction of progressive myopia spectacle lens changes were more significant, the dynamics of early school leaving amounted to 0,36±0,11 mm. Conclusion. The identified inhibitory effect of OK-lenses on myopia progression, confirmed by the indices of refraction and ultrasound biometry within 2 years of the study. The data allow us to recommend OK-therapy, as an effective tool for progressive myopia.

  18. Prevalence and Distribution of Segmentation Errors in Macular Ganglion Cell Analysis of Healthy Eyes Using Cirrus HD-OCT.

    Directory of Open Access Journals (Sweden)

    Rayan A Alshareef

    Full Text Available To determine the frequency of different types of spectral domain optical coherence tomography (SD-OCT scan artifacts and errors in ganglion cell algorithm (GCA in healthy eyes.Infrared image, color-coded map and each of the 128 horizontal b-scans acquired in the macular ganglion cell-inner plexiform layer scans using the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA macular cube 512 × 128 protocol in 30 healthy normal eyes were evaluated. The frequency and pattern of each artifact was determined. Deviation of the segmentation line was classified into mild (less than 10 microns, moderate (10-50 microns and severe (more than 50 microns. Each deviation, if present, was noted as upward or downward deviation. Each artifact was further described as per location on the scan and zones in the total scan area.A total of 1029 (26.8% out of total 3840 scans had scan errors. The most common scan error was segmentation error (100%, followed by degraded images (6.70%, blink artifacts (0.09% and out of register artifacts (3.3%. Misidentification of the inner retinal layers was most frequent (62%. Upward Deviation of the segmentation line (47.91% and severe deviation (40.3% were more often noted. Artifacts were mostly located in the central scan area (16.8%. The average number of scans with artifacts per eye was 34.3% and was not related to signal strength on Spearman correlation (p = 0.36.This study reveals that image artifacts and scan errors in SD-OCT GCA analysis are common and frequently involve segmentation errors. These errors may affect inner retinal thickness measurements in a clinically significant manner. Careful review of scans for artifacts is important when using this feature of SD-OCT device.

  19. Intraoperative radiotherapy (IORT) with low-energy photons as a boost in patients with early-stage oral cancer with the indications for postoperative radiotherapy. Treatment feasibility and preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Rutkowski, Tomasz; Wygoda, Andrzej; Hutnik, Marcin; Skladowski, Krzysztof; Wydmanski, Jerzy; Maciejewski, Boguslaw [Dept. of Radiation Oncology, Maria Sklodowska-Curie Memorial Cancer and Inst. of Oncology, Gliwice Branch (Poland); Maciejewski, Adam; Szymczyk, Cezary; Wierzgon, Janusz [Dept. of Surgery, Maria Sklodowska-Curie Memorial Cancer Center and Inst. of Oncology, Gliwice Branch (Poland); Orlef, Andrzej [Dept. of Physics, Maria Sklodowska-Curie Memorial Cancer Center and Inst. of Oncology, Gliwice Branch (Poland)

    2010-09-15

    Purpose: To evaluate the feasibility and preliminary results of intraoperative radiotherapy (IORT) with low-energy photons as a boost in patients with early-stage oral cancer with the indications for postoperative radiotherapy. Patients and Methods: Between 2003 and 2006, 16 patients with early-stage cancer of mobile tongue (n = 10 [63%]) or floor of the mouth (n = 6 [37%]) treated at Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, Poland, were evaluated for IORT boost with the INTRABEAM {sup registered} System (Carl Zeiss Surgical GmbH; IORT-PRS) because of the high risk of local recurrence due to positive margins on frozen pathologic section. After tumor resection, the applicator was positioned in the tumor bed. The applicator's diameter (range: 1.5-5 cm) was selected to encompass high-risk area of tumor recurrence. The dose (5 Gy, 7 Gy, or 7.5 Gy) was applied according to tumor volume and bone proximity. External-beam radiotherapy (EBRT) was provided to the tumor bed in all patients (50 Gy) and to the nodal area, when needed. Toxicity and local tumor control were assessed. Results: Median follow-up was 36 months. IORT did not increase acute mucosal reaction. Local tumor control was found in all cases. Early mucosal reaction did not exceed 3 according to the RTOG scale and healed in median time of 35 days after completion of EBRT. No late adverse effects were observed. Conclusion: This preliminary report has demonstrated the feasibility of IORT-PRS for patients with early oral cancer with the indications for postoperative radiotherapy. This method may be considered an alternative boost technique, although additional studies are needed to establish long-term results in a larger group of patients. (orig.)

  20. Preferential Hyperacuity Perimeter (PreView PHP) for detecting choroidal neovascularization study.

    Science.gov (United States)

    Alster, Yair; Bressler, Neil M; Bressler, Susan B; Brimacombe, Judith A; Crompton, R Michael; Duh, Yi-Jing; Gabel, Veit-Peter; Heier, Jeffrey S; Ip, Michael S; Loewenstein, Anat; Packo, Kirk H; Stur, Michael; Toaff, Techiya

    2005-10-01

    To assess the ability of the Preferential Hyperacuity Perimeter (PreView PHP; Carl Zeiss Meditec, Dublin, CA) to detect recent-onset choroidal neovascularization (CNV) resulting from age-related macular degeneration (AMD) and to differentiate it from an intermediate stage of AMD. Prospective, comparative, concurrent, nonrandomized, multicenter study. Eligible participants' study eyes had a corrected visual acuity of 20/160 or better and either untreated CNV from AMD diagnosed within the last 60 days or an intermediate stage of AMD. After obtaining consent, visual acuity with habitual correction, masked PHP testing, stereoscopic color fundus photography, and fluorescein angiography were performed. Photographs and angiograms were evaluated by graders masked to diagnosis and PHP results. The reading center's diagnosis determined if the patient was categorized as having intermediate AMD or neovascular AMD. A successful study outcome was defined a priori as a sensitivity of at least 80% and a specificity of at least 80%. Of 185 patients who gave consent to be enrolled, 11 (6%) had PHP results judged to be unreliable. An additional 52 were not included because they did not meet all eligibility criteria. Of the remaining 122 patients, 57 had an intermediate stage of AMD and 65 had neovascular AMD. The sensitivity to detect newly diagnosed CNV using PHP testing was 82% (95% confidence interval [CI], 70%-90%). The specificity to differentiate newly diagnosed CNV from the intermediate stage of AMD using PHP testing was 88% (95% CI, 76%-95%). Preferential Hyperacuity Perimeter testing can detect recent-onset CNV resulting from AMD and can differentiate it from an intermediate stage of AMD with high sensitivity and specificity. These data suggest that monitoring with PHP should detect most cases of CNV of recent onset with few false-positive results at a stage when treatment usually would be beneficial. Thus, this monitoring should be considered in the management of the

  1. RESEARCH OF THE ENTRANCE ANGLE EFFECT ON THE REFLECTANCE SPECTRA OF THE STAINLESS STEEL SURFACE OXIDIZED BY PULSED LASER RADIATION

    Directory of Open Access Journals (Sweden)

    V. P. Veiko

    2016-05-01

    Full Text Available Subject of Research.Oxide films on the metal surfaces can be obtained both by surface-uniform infrared heating and local laser treatment e.g. by sequence of nanosecond laser pulses. Due to interference in created films the coloration of treated area is observed. The present work shows the results of spectrophotometric measurements for various light entrance angles in the range of 10-60°. Method. AISI 304 stainless steel plates were oxidized by two methods: in muffle furnace FM - 10 (Т= 500-600° С, t = 5-7 min. and at line-by-line scanning by sequence of nanosecond laser pulses (λ = 1.06 μm, τ =100 ns, r = 25 μm,q=2.91∙107 W/cm2, Nx = 30, Ny = 1. Surface research in optical resolution was realized by Carl Zeiss Axio Imager A1M. Reflectance spectra were obtained with spectrophotometer Lambda Perkin 1050 with integrating sphere at different fixed light incidence angles. Topographic features were detected by scanning probe microscopy investigation with NanoEducator equipment. Main Results. The quantitative surface geometry characteristics of AISI 304 stainless steel patterns treated by different methods are obtained. It was found that the increase of light entrance angle has no influence on the form of reflection coefficient dependence from a wavelength, but a blue-shift occurs especially for the case of laser treatment. This difference can be caused by surface topology formed by laser heating and variety of oxide film thickness. This effect results in more significant change in observed sample color for laser treatment then for infrared heating. Practical Relevance. The results obtained in the present work can be used to implement a new element of product protection against forgery with the product marking.

  2. Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.

    Science.gov (United States)

    Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C

    2017-11-01

    To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography

    Directory of Open Access Journals (Sweden)

    Nikoo Hamzeh

    2015-12-01

    Full Text Available AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT in comparison with A-scan ultrasonography (A-scan US. METHODS: There were 218 adult subjects (218 eyes aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III. Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA. The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74. Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001, and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001 CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.

  4. Nonlinear optics for the study of human scar tissue

    Science.gov (United States)

    Ferro, D. P.; Vieira-Damiani, G.; Adam, R. L.; Cesar, C. L.; Metze, Konradin

    2012-03-01

    Collagen fibers are an essential component of the dynamic process of scarring, which accompanies various diseases. Scar tissue may reveal different morphologic expressions, such as hypertrophic scars or keloids. Collagen fibers can be visualized by fluorescent light when stained with eosin. Second Harmonic Generation (SHG) creates a non linear signal that occurs only in molecules without inversion symmetry and is particularly strong in the collagen fibers arranged in triple helices. The aim of this study was to describe the methodology for the analysis of the density and texture of collagen in keloids, hypertrophic scars and conventional scars. Samples were examined in the National Institute of Science and Technology on Photonics Applied to Cell Biology (INFABIC) at the State University of Campinas. The images were acquired in a multiphoton microscopy LSM 780-NLO Zeiss 40X. Both signals, two-photon fluorescence (TPEF) and SHG, were excited by a Mai-Tai Ti:Sapphire laser at 940 nm. We used a LP490/SP485 NDD filter for SHG, and a BP565-610 NDD filter for fluorescence In each case, ten images were acquired serially (512×512 μm) in Z-stack and joined together to one patchwork-image . Image analysis was performed by a gliding-box-system with in-house made software. Keloids, hypertrophic scars and normal scar tissue show different collagen architecture. Inside an individual case differences of the scar process may be found between central and peripheral parts. In summary, the use of nonlinear optics is a helpful tool for the study of scars tissue.

  5. [LenSx® femto-LASIK, FEMTO LDV Z4® femto-LASIK, and PRK : Comparison of refractive results and an analysis of complications].

    Science.gov (United States)

    Pahlitzsch, T; Pahlitzsch, M-L; Sumarni, U; Pahlitzsch, M

    2017-10-30

    The aim of this study is to evaluate three refractive procedures: LenSx® (Alcon, Fort Worth, TX, USA) femto-laser in situ keratomileusis (LASIK), FEMTO LDV Z4® (Ziemer, Port, Switzerland) femto-LASIK, and photorefractive keratectomy (PRK) in terms of refractive outcome, perioperative complications, pain, and patient satisfaction. Data of 168 eyes (myopic n = 84) were included in this retrospective study. Of these, 54 eyes (n = 27, 33.85 ± 7.64 years) were treated with LenSx® femto-LASIK, 60 eyes (n = 30, 35.03 ± 7.46 years) with FEMTO LDV Z4® femto-LASIK, and 54 eyes (n = 27, 33.24 ± 8.52 years) with PRK. Photoablation was induced by a MEL80 Excimerlaser (Zeiss, Oberkochen, Germany). The corrected (V sc ) and uncorrected (V cc ) distance subjective visual acuity, corneal topography (Pentacam® HR; Wetzlar, Germany), and objective astigmatism (ARK-760A Refractometer ; Nidek, Fremont, CA, USA) were measured preoperatively, and 1 day, 1 week, 1 month, and 3 months postoperatively. Subjective pain (verbal rating scale) and patient satisfaction were also recorded. Subjective V sc showed significantly better results in both femto-LASIK cohorts compared to PRK (p PRK cohorts (p = 0.072). LDV Z4® femto-LASIK showed the lowest pain score 1 day postoperatively (p PRK. There is no difference between the three techniques regarding refractive outcome after 3 months follow-up. LDV Z4® femto-LASIK can be recommended, if available, due to its low intraoperative complication rate and higher patient satisfaction compared to LenSx® femto-LASIK.

  6. Comparison of clinical outcomes in PRK with a standard and aspherical optimized profile: a full case analysis of 100 eyes with 1-year follow-up

    Directory of Open Access Journals (Sweden)

    Dausch D

    2014-11-01

    Full Text Available Dieter Dausch,1,2 Burglinde Dausch,2 Matthias Wottke,3 Georg Sluyterman van Langeweyde31Chung-Ang University, Seoul, South Korea; 2Augen-Laser-Klinik Nürnberg, Nuremberg, Germany; 3Carl Zeiss Meditec AG, Jena, Germany Purpose: One hundred eyes from 55 adult patients with myopia were retrospectively studied to determine the comparative safety, efficacy, and predictability of aberration smart ablation (ASA and a new advanced ablation algorithm (Triple-A using the MEL® 80 excimer laser.Methods: Fifty myopic eyes with a manifest refraction spherical equivalent (MRSE between -1.0 diopters (D and -9.75 D were consecutively treated with photorefractive keratectomy ASA, and 50 myopic eyes with an MRSE between -1.38 D and -11.0 D with photorefractive keratectomy Triple-A. Uncorrected distance visual acuity, MRSE, the absolute value of the cylinder, corrected distance visual acuity, and postoperative complications at 1 month, 3 months, 6 months, and 12 months (1 year were descriptively analyzed and compared at 1 year.Results: After 12 months, the MRSE variance was statistically significantly better in patients triaged to receive Triple-A compared with patients receiving ASA (ASA, ±0.7 D; Triple-A, ±0.15 D; P<0.001. Furthermore, no patient in the Triple-A group had any cylinder postoperatively. Patients in the Triple-A treatment arm achieved a superior result. No statistically significant difference in the two treatment arms was noted for the analysis of the mean MRSE at 12 months (P=0.78.Conclusion: Triple-A was more effective than standard aspherical surgical intervention in a number of treatment outcome parameters (eg, MRSE, astigmatism, efficacy index. The two surgical procedures were equivalent in terms of safety. Keywords: aberration smart ablation (ASA, manifest refraction spherical equivalent, Triple-A advanced ablation algorithm, uncorrected distance visual acuity, corrected distance visual acuity, excimer laser, PRK, ablation profile

  7. Biometry of myopia in college students: IOL-Master study

    Directory of Open Access Journals (Sweden)

    Yuan-Yuan Du

    2013-05-01

    Full Text Available AIM: To measure axial length(AL, horizontal and vertical corneal refractive power(K1, K2, anterior chamber depth(ACDand corneal diameter(white to whiteof myopia in college students by IOL-Master(Zeiss Humphrey Systemsand detect the correlation between diopter and all above refractive components. METHODS: The IOL-Master was used in the measurement of the AL, K1, K2, ACD and corneal diameter(white to whitein 1 059 college students(2 118 eyeswith myopia, and AL/CR was calculated. Their diopter was measured by computer refractor. They were divided into three groups according to different mean spherical equivalent diopters: group A of low myopia: -6.00D(391 eyes. The SPSS 18.0 was used for the statistical analysis. RESULTS: With the increase of diopter, the AL in myopia eyes was increased and the AL increased significantly in each myopia group(P0.05and there were significant differences among three groups in K2(P0.05, but there was only significant correlation between ACD and refractive error in low myopia(P0.05and also there was no significant correlation between corneal diameter and refractive error in three groups(P>0.05. AL/CR was 3.183±0.132, the AL/CR ratio was negatively correlated with diopter of myopia(r=-0.761,P=0.000. CONCLUSION: The development of axial length is the main reason in myopia of college students. Middle myopia is induced by both axial length and refractive power. ACD has little effects on diopter of myopia, but corneal diameter has no effects on diopter of myopia.

  8. Automated Quantitative Rare Earth Elements Mineralogy by Scanning Electron Microscopy

    Science.gov (United States)

    Sindern, Sven; Meyer, F. Michael

    2016-09-01

    Increasing industrial demand of rare earth elements (REEs) stems from the central role they play for advanced technologies and the accelerating move away from carbon-based fuels. However, REE production is often hampered by the chemical, mineralogical as well as textural complexity of the ores with a need for better understanding of their salient properties. This is not only essential for in-depth genetic interpretations but also for a robust assessment of ore quality and economic viability. The design of energy and cost-efficient processing of REE ores depends heavily on information about REE element deportment that can be made available employing automated quantitative process mineralogy. Quantitative mineralogy assigns numeric values to compositional and textural properties of mineral matter. Scanning electron microscopy (SEM) combined with a suitable software package for acquisition of backscatter electron and X-ray signals, phase assignment and image analysis is one of the most efficient tools for quantitative mineralogy. The four different SEM-based automated quantitative mineralogy systems, i.e. FEI QEMSCAN and MLA, Tescan TIMA and Zeiss Mineralogic Mining, which are commercially available, are briefly characterized. Using examples of quantitative REE mineralogy, this chapter illustrates capabilities and limitations of automated SEM-based systems. Chemical variability of REE minerals and analytical uncertainty can reduce performance of phase assignment. This is shown for the REE phases parisite and synchysite. In another example from a monazite REE deposit, the quantitative mineralogical parameters surface roughness and mineral association derived from image analysis are applied for automated discrimination of apatite formed in a breakdown reaction of monazite and apatite formed by metamorphism prior to monazite breakdown. SEM-based automated mineralogy fulfils all requirements for characterization of complex unconventional REE ores that will become

  9. Photoreceptor layer map using spectral-domain optical coherence tomography.

    Science.gov (United States)

    Lee, Ji Eun; Lim, Dae Won; Bae, Han Yong; Park, Hyun Jin

    2009-12-01

    To develop a novel method for analysis of the photoreceptor layer map (PLM) generated using spectral-domain optical coherence tomography (OCT). OCT scans were obtained from 20 eyes, 10 with macular holes (MH) and 10 with central serous chorioretinopathy (CSC) using the Macular Cube (512 x 128) protocol of the Cirrus HD-OCT (Carl Zeiss). The scanned data were processed using embedded tools of the advanced visualization. A partial thickness OCT fundus image of the photoreceptor layer was generated by setting the region of interest to a 50-microm thick layer that was parallel and adjacent to the retinal pigment epithelium. The resulting image depicted the photoreceptor layer as a map of the reflectivity in OCT. The PLM was compared with fundus photography, auto-fluorescence, tomography, and retinal thickness map. The signal from the photoreceptor layer of every OCT scan in each case was demonstrated as a single image of PLM in a fundus photograph fashion. In PLM images, detachment of the sensory retina is depicted as a hypo-reflective area, which represents the base of MH and serous detachment in CSC. Relative hypo-reflectivity, which was also noted at closed MH and at recently reattached retina in CSC, was associated with reduced signal from the junction between the inner and outer segments of photoreceptors in OCT images. Using PLM, changes in the area of detachment and reflectivity of the photoreceptor layer could be efficiently monitored. The photoreceptor layer can be analyzed as a map using spectral-domain OCT. In the treatment of both MH and CSC, PLM may provide new pathological information about the photoreceptor layer to expand our understanding of these diseases.

  10. Mapping microscopic order in plant and mammalian cells and tissues: novel differential polarization attachment for new generation confocal microscopes (DP-LSM)

    Science.gov (United States)

    Steinbach, G.; Pawlak, K.; Pomozi, I.; Tóth, E. A.; Molnár, A.; Matkó, J.; Garab, G.

    2014-03-01

    Elucidation of the molecular architecture of complex, highly organized molecular macro-assemblies is an important, basic task for biology. Differential polarization (DP) measurements, such as linear (LD) and circular dichroism (CD) or the anisotropy of the fluorescence emission (r), which can be carried out in a dichrograph or spectrofluorimeter, respectively, carry unique, spatially averaged information about the molecular organization of the sample. For inhomogeneous samples—e.g. cells and tissues—measurements on macroscopic scale are not satisfactory, and in some cases not feasible, thus microscopic techniques must be applied. The microscopic DP-imaging technique, when based on confocal laser scanning microscope (LSM), allows the pixel by pixel mapping of anisotropy of a sample in 2D and 3D. The first DP-LSM configuration, which, in fluorescence mode, allowed confocal imaging of different DP quantities in real-time, without interfering with the ‘conventional’ imaging, was built on a Zeiss LSM410. It was demonstrated to be capable of determining non-confocally the linear birefringence (LB) or LD of a sample and, confocally, its FDLD (fluorescence detected LD), the degree of polarization (P) and the anisotropy of the fluorescence emission (r), following polarized and non-polarized excitation, respectively (Steinbach et al 2009 Acta Histochem.111 316-25). This DP-LSM configuration, however, cannot simply be adopted to new generation microscopes with considerably more compact structures. As shown here, for an Olympus FV500, we designed an easy-to-install DP attachment to determine LB, LD, FDLD and r, in new-generation confocal microscopes, which, in principle, can be complemented with a P-imaging unit, but specifically to the brand and type of LSM.

  11. MEDEA+ project 2T302 MUSCLE: masks through user's supply chain: leadership by excellence

    Science.gov (United States)

    Torsy, Andreas

    2008-04-01

    The rapid evolution of our information society depends on the continuous developments and innovations of semiconductor products. The cost per chip functionality keeps reducing by a factor of 2 every 18 month. However, this performance and success of the semiconductor industry critically depends on the quality of the lithographic photomasks. The need for the high quality of photomask drives lithography costs sensitively, which is a key factor in the manufacture of microelectronics devices. Therefore, the aim is to reduce production costs while overcoming challenges in terms of feature sizes, complexity and cycle times. Consequently, lithography processes must provide highest possible quality at reasonable prices. This way, the leadership in the lithographic area can be maintained and European chipmakers can stay competitive with manufacturers in the Far East and the USA. Under the umbrella of MEDEA+, a project called MUSCLE (>) has been started among leading semiconductor companies in Europe: ALTIS Semiconductor (Project Leader), ALCATEL Vacuum, ATMEL, CEA/LETI, Entegris, NXP Semiconductors, TOPPAN Photomasks, AMTC, Carl ZEISS SMS, DMS, Infineon Technologies, VISTEC Semiconductor, NIKON Precision, SCHOTT Lithotec, ASML, PHOTRONICS, IMEC, DCE, DNP Photomask, STMicroelectronics, XYALIS and iCADA. MUSCLE focuses particularly on mask data flow, photomask carrier, photomask defect characterization and photomask data handling. In this paper, we will discuss potential solutions like standardization and automation of the photomask data flow based on SEMI P10, the performance and the impact of the supply chain parameter within the photomask process, the standardization of photomask defect characterization and a discussion of the impact of new Reticle Enhancement Technologies (RET) such as mask process correction and finally a generic model to describe the photomasks key performance indicators for prototype photomasks.

  12. Reliability of widefield capillary microscopy to measure nailfold capillary density in systemic sclerosis.

    Science.gov (United States)

    Hudson, M; Masetto, A; Steele, R; Arthurs, E; Baron, M

    2010-01-01

    To determine intra- and inter-observer reliability of widefield microscopy to measure nailfold capillary density in patients with systemic sclerosis (SSc). Five SSc patients were examined with a STEMV-8 Zeiss biomicroscope with 50x magnification. The nailfold of the second, third, fourth and fifth fingers of both hands of each patient were photographed twice by each of two observers, once in the morning and again in the afternoon (total of 32 pictures). Two raters reviewed the photographs to produce capillary density readings. Intra- and inter-rater reliability of the readings were computed using intra-class correlations (ICC). Additional analyses were undertaken to determine the impact of other sources of variability in the data, namely patient, finger, technician and time. Intra-and inter-rater reliability were substantial (ICC 0.72-0.84) when raters were reading the same photographs or photographs taken at the same time of day. Agreement was only fair between morning and afternoon density readings (ICC 0.30-0.37). Patients, individual fingers and technician accounted for a large part of the variability in the data (combined variance component of 7.69 out of the total 12.23). The coefficient of variation of widefield microscopy was 24%. Although intra- and inter-rater reliability of nailfold capillary density measurements using widefield microscopy are good, proper standardisation of the conditions under which capillaroscopy is done and better imaging of nailfold capillary abnormalities should be considered if nailfold capillary density is to be used as an outcome measure in multi-centre clinical trials in SSc.

  13. Segmentation of the geographic atrophy in spectral-domain optical coherence tomography and fundus autofluorescence images.

    Science.gov (United States)

    Hu, Zhihong; Medioni, Gerard G; Hernandez, Matthias; Hariri, Amirhossein; Wu, Xiaodong; Sadda, Srinivas R

    2013-12-30

    Geographic atrophy (GA) is the atrophic late-stage manifestation of age-related macular degeneration (AMD), which may result in severe vision loss and blindness. The purpose of this study was to develop a reliable, effective approach for GA segmentation in both spectral-domain optical coherence tomography (SD-OCT) and fundus autofluorescence (FAF) images using a level set-based approach and to compare the segmentation performance in the two modalities. To identify GA regions in SD-OCT images, three retinal surfaces were first segmented in volumetric SD-OCT images using a double-surface graph search scheme. A two-dimensional (2-D) partial OCT projection image was created from the segmented choroid layer. A level set approach was applied to segment the GA in the partial OCT projection image. In addition, the algorithm was applied to FAF images for the GA segmentation. Twenty randomly chosen macular SD-OCT (Zeiss Cirrus) volumes and 20 corresponding FAF (Heidelberg Spectralis) images were obtained from 20 subjects with GA. The algorithm-defined GA region was compared with consensus manual delineation performed by certified graders. The mean Dice similarity coefficients (DSC) between the algorithm- and manually defined GA regions were 0.87 ± 0.09 in partial OCT projection images and 0.89 ± 0.07 in registered FAF images. The area correlations between them were 0.93 (P segment GA regions in both SD-OCT and FAF images. This approach demonstrated good agreement between the algorithm- and manually defined GA regions within each single modality. The GA segmentation in FAF images performed better than in partial OCT projection images. Across the two modalities, the GA segmentation presented reasonable agreement.

  14. Visualization and quantitation of abundant macroautophagy in virus-infected cells by confocal three-dimensional fluorescence imaging.

    Science.gov (United States)

    Jackson, Wallen; Yamada, Masaki; Moninger, Thomas; Grose, Charles

    2013-10-01

    Varicella-zoster virus (VZV) is a human herpesvirus. Primary infection causes varicella (chickenpox), a viremic illness typified by an exanthem consisting of several hundred vesicles. When VZV reactivates from latency in the spinal ganglia during late adulthood, the emerging virus causes a vesicular dermatomal rash (herpes zoster or shingles). To expand investigations of autophagy during varicella and zoster, newer 3D imaging technology was combined with laser scanning confocal microscopy to provide animations of autophagosomes in the vesicular rash. First, the cells were immunolabeled with antibodies against VZV proteins and the LC3 protein, an integral autophagosomal protein. Antibody reagents lacking activity against the human blood group A1 antigen were selected. After laser excitation of the samples, optimized emission detection bandwidths were configured by Zeiss Zen control software. Confocal Z-stacks comprising up to 40 optical slices were reconstructed into 3D animations with the aid of Imaris software. With this imaging technology, individual autophagosomes were clearly detectable as spheres within each vesicular cell. To enumerate the number of autophagosomes, data sets from 50 cells were reconstructed as 3D fluorescence images and analyzed with MeasurementPro software. The mean number of autophagosomes per infected vesicular cell was >100, although over 200 autophagosomes were seen in a few cells. In summary, macroautophagy was easily quantitated within VZV-infected cells after immunolabeling and imaging by 3D confocal animation technology. These same 3D imaging techniques will be applicable for investigations of autophagy in other virus-infected cells. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Whole plant based treatment of hypercholesterolemia with Crataegus laevigata in a zebrafish model

    Directory of Open Access Journals (Sweden)

    Littleton Robert M

    2012-07-01

    Full Text Available Abstract Background Consumers are increasingly turning to plant-based complementary and alternative medicines to treat hypercholesterolemia. Many of these treatments are untested and their efficacy is unknown. This multitude of potential remedies necessitates a model system amenable to testing large numbers of organisms that maintains similarity to humans in both mode of drug administration and overall physiology. Here we develop the larval zebrafish (4–30 days post fertilization as a vertebrate model of dietary plant-based treatment of hypercholesterolemia and test the effects of Crataegus laevigata in this model. Methods Larval zebrafish were fed high cholesterol diets infused with fluorescent sterols and phytomedicines. Plants were ground with mortar and pestle into a fine powder before addition to food. Fluorescent sterols were utilized to optically quantify relative difference in intravascular cholesterol levels between groups of fish. We utilized the Zeiss 7-Live Duo high-speed confocal platform in order to both quantify intravascular sterol fluorescence and to capture video of the heart beat for determination of cardiac output. Results In this investigation we developed and utilized a larval zebrafish model to investigate dietary plant-based intervention of the pathophysiology of hypercholesterolemia. We found BODIPY-cholesterol effectively labels diet-introduced intravascular cholesterol levels (P t-test. We also established that zebrafish cardiac output declines as cholesterol dose increases (difference between 0.1% and 8% (w/w high cholesterol diet-treated cardiac output significant at P  Conclusions The results of this study demonstrate that the larval zebrafish has the potential to become a powerful model to test plant based dietary intervention of hypercholesterolemia. Using this model we have shown that hawthorn leaves and flowers have the potential to affect cardiac output as well as intravascular cholesterol levels

  16. Mapping glaucoma patients' 30-2 and 10-2 visual fields reveals clusters of test points damaged in the 10-2 grid that are not sampled in the sparse 30-2 grid.

    Directory of Open Access Journals (Sweden)

    Ryo Asaoka

    Full Text Available PURPOSE: To cluster test points in glaucoma patients' 30-2 and 10-2 visual field (VF (Humphrey Field Analyzer: HFA, Carl Zeiss Meditec, Dublin, CA in order to map the different regions damaged by the disease. METHOD: This retrospective study included 128 eyes from 128 patients. 142 total deviation (TD values (74 from the 30-2 VF and 68 from the 10-2 VF were clustered using the 'Hierarchical Ordered Partitioning And Collapsing Hybrid-Partitioning Around Medoids' algorithm. The stability of the identified clusters was evaluated using bootstrapping. RESULTS: 65 sectors were identified in total: 38 sectors were located outside the 10-2 VF whereas 29 sectors were located inside the 10-2 VF (two sectors overlap in both grids. The mapping of many sectors appeared to follow the distribution of retinal nerve fiber bundles. The results of bootstrapping suggested clusters were stable whether they were outside or inside the 10-2 VF. CONCLUSION: A considerable number of sectors were identified in the 10-2 VF area, despite the fact that clustering was carried out on all points in both the 30-2 VF and 10-2 VF simultaneously. These findings suggest that glaucomatous central VF deterioration cannot be picked up by the 30-2 test grid alone, because of poor spatial sampling; denser estimation of the central ten degrees, than offered by the 30-2 test grid alone, is needed. It may be beneficial to develop a new VF test grid that combines test points from 30-2 and 10-2 VFs--the results of this study could help to devise this test grid.

  17. Computed image analysis of neutron radiographs

    International Nuclear Information System (INIS)

    Dinca, M.; Anghel, E.; Preda, M.; Pavelescu, M.

    2008-01-01

    Similar with X-radiography, using neutron like penetrating particle, there is in practice a nondestructive technique named neutron radiology. When the registration of information is done on a film with the help of a conversion foil (with high cross section for neutrons) that emits secondary radiation (β,γ) that creates a latent image, the technique is named neutron radiography. A radiographic industrial film that contains the image of the internal structure of an object, obtained by neutron radiography, must be subsequently analyzed to obtain qualitative and quantitative information about the structural integrity of that object. There is possible to do a computed analysis of a film using a facility with next main components: an illuminator for film, a CCD video camera and a computer (PC) with suitable software. The qualitative analysis intends to put in evidence possibly anomalies of the structure due to manufacturing processes or induced by working processes (for example, the irradiation activity in the case of the nuclear fuel). The quantitative determination is based on measurements of some image parameters: dimensions, optical densities. The illuminator has been built specially to perform this application but can be used for simple visual observation. The illuminated area is 9x40 cm. The frame of the system is a comparer of Abbe Carl Zeiss Jena type, which has been adapted to achieve this application. The video camera assures the capture of image that is stored and processed by computer. A special program SIMAG-NG has been developed at INR Pitesti that beside of the program SMTV II of the special acquisition module SM 5010 can analyze the images of a film. The major application of the system was the quantitative analysis of a film that contains the images of some nuclear fuel pins beside a dimensional standard. The system was used to measure the length of the pellets of the TRIGA nuclear fuel. (authors)

  18. Corneal ablation depth readout of the MEL 80 excimer laser compared to Artemis three-dimensional very high-frequency digital ultrasound stromal measurements.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Gobbe, Marine

    2010-12-01

    To evaluate the accuracy of the ablation depth readout for the MEL 80 excimer laser (Carl Zeiss Meditec). Artemis 1 very high-frequency digital ultrasound measurements were obtained before and at least 3 months after LASIK in 121 eyes (65 patients). The Artemis-measured ablation depth was calculated as the maximum difference in stromal thickness before and after treatment. Laser in situ keratomileusis was performed using the MEL 80 excimer laser and the Hansatome microkeratome (Bausch & Lomb). The Aberration Smart Ablation profile was used in 56 eyes and the Tissue Saving Ablation profile was used in 65 eyes. All ablations were centered on the corneal vertex. Comparative statistics and linear regression analysis were performed between the laser readout ablation depth and Artemis-measured ablation depth. The mean maximum myopic meridian was -6.66±2.40 diopters (D) (range: -1.50 to -10.00 D) for Aberration Smart Ablation-treated eyes and -6.50±2.56 D (range: -1.34 to -11.50 D) for Tissue Saving Ablation-treated eyes. The MEL 80 readout was found to overestimate the Artemis-measured ablation depth by 20±12 μm for Aberration Smart Ablation and by 21±12 μm for Tissue Saving Ablation profiles. The accuracy of ablation depth measurement was improved by using the Artemis stromal thickness profile measurements before and after surgery to exclude epithelial changes. The MEL 80 readout was found to overestimate the achieved ablation depth. The linear regression equations could be used by MEL 80 users to adjust the ablation depth for predicted residual stromal thickness calculations without increasing the risk of ectasia due to excessive keratectomy depth as long as a suitable flap thickness bias is included. Copyright 2010, SLACK Incorporated.

  19. Comparisons Between Histology and Optical Coherence Tomography Angiography of the Periarterial Capillary-Free Zone.

    Science.gov (United States)

    Balaratnasingam, Chandrakumar; An, Dong; Sakurada, Yoichi; Lee, Cecilia S; Lee, Aaron Y; McAllister, Ian L; Freund, K Bailey; Sarunic, Marinko; Yu, Dao-Yi

    2018-05-01

    To use the capillary-free zone along retinal arteries, a physiologic area of superficial avascularization, as an anatomic paradigm to investigate the reliability of optical coherence tomography angiography (OCTA) for visualizing the deep retinal circulation. Validity analysis and laboratory investigation. Five normal human donor eyes (mean age 69.8 years) were perfusion-labeled with endothelial antibodies and the capillary networks of the perifovea were visualized using confocal scanning laser microscopy. Regions of the capillary-free zone along the retinal artery were imaged using OCTA in 16 normal subjects (age range 24-51 years). Then, 3 × 3-mm scans were acquired using the RTVue XR Avanti (ver. 2016.1.0.26; Optovue, Inc, Fremont, California, USA), PLEX Elite 9000 (ver. 1.5.0.15909; Zeiss Meditec, Inc, Dublin, California, USA), Heidelberg Spectralis OCT2 (Family acquisition module 6.7.21.0; Heidelberg Engineering, Heidelberg, Germany), and DRI-OCT Triton (Ver. 1.1.1; Topcon Corp, Tokyo, Japan). Images of the superficial plexus, deep vascular plexus, and a slab containing all vascular plexuses were generated using manufacturer-recommended default settings. Comparisons between histology and OCTA were performed. Histologic analysis revealed that the capillary-free zone along the retinal artery was confined to the plane of the superficial capillary plexus and did not include the intermediate and deep capillary plexuses. Images derived from OCTA instruments demonstrated a prominent capillary-free zone along the retinal artery in slabs of the superficial plexus, deep plexus, and all capillary plexuses. The number of deep retinal capillaries seen in the capillary-free zone was significantly greater on histology than on OCTA (P zone as an anatomic paradigm, we show that the deep vascular beds of the retina are not completely visualized using OCTA. This may be a limitation of current OCTA techniques. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Space- and Ground-based Coronal Spectro-Polarimetry

    Science.gov (United States)

    Fineschi, Silvano; Bemporad, Alessandro; Rybak, Jan; Capobianco, Gerardo

    This presentation gives an overview of the near-future perspectives of ultraviolet and visible-light spectro-polarimetric instrumentation for probing coronal magnetism from space-based and ground-based observatories. Spectro-polarimetric imaging of coronal emission-lines in the visible-light wavelength-band provides an important diagnostics tool of the coronal magnetism. The interpretation in terms of Hanle and Zeeman effect of the line-polarization in forbidden emission-lines yields information on the direction and strength of the coronal magnetic field. As study case, this presentation will describe the Torino Coronal Magnetograph (CorMag) for the spectro-polarimetric observation of the FeXIV, 530.3 nm, forbidden emission-line. CorMag - consisting of a Liquid Crystal (LC) Lyot filter and a LC linear polarimeter - has been recently installed on the Lomnicky Peak Observatory 20cm Zeiss coronagraph. The preliminary results from CorMag will be presented. The linear polarization by resonance scattering of coronal permitted line-emission in the ultraviolet (UV)can be modified by magnetic fields through the Hanle effect. Space-based UV spectro-polarimeters would provide an additional tool for the disgnostics of coronal magnetism. As a case study of space-borne UV spectro-polarimeters, this presentation will describe the future upgrade of the Sounding-rocket Coronagraphic Experiment (SCORE) to include the capability of imaging polarimetry of the HI Lyman-alpha, 121.6 nm. SCORE is a multi-wavelength imager for the emission-lines, HeII 30.4 nm and HI 121.6 nm, and visible-light broad-band emission of the polarized K-corona. SCORE has flown successfully in 2009. This presentation will describe how in future re-flights SCORE could observe the expected Hanle effect in corona with a HI Lyman-alpha polarimeter.

  1. ON THE ORIGIN OF INTERGRANULAR JETS

    International Nuclear Information System (INIS)

    Yurchyshyn, V. B.; Goode, P. R.; Abramenko, V. I.; Steiner, O.

    2011-01-01

    We observe that intergranular jets, originating in the intergranular space surrounding individual granules, tend to be associated with granular fragmentation, in particular, with the formation and evolution of a bright granular lane (BGL) within individual granules. The BGLs have recently been identified as vortex tubes by Steiner et al. We further discover the development of a well-defined bright grain located between the BGL and the dark intergranular lane to which it is connected. Signatures of a BGL may reach the lower chromosphere and can be detected in off-band Hα images. Simulations also indicate that vortex tubes are frequently associated with small-scale magnetic fields. We speculate that the intergranular jets detected in the New Solar Telescope (NST) data may result from the interaction between the turbulent small-scale fields associated with the vortex tube and the larger-scale fields existing in the intergranular lanes. The intergranular jets are much smaller and weaker than all previously known jet-like events. At the same time, they appear much more numerous than the larger events, leading us to the speculation that the total energy release and mass transport by these tiny events may not be negligible in the energy and mass-flux balance near the temperature minimum atop the photosphere. The study is based on the photospheric TiO broadband (1.0 nm) filter data acquired with the 1.6 m NST operating at the Big Bear Solar Observatory. The data set also includes NST off-band Hα images collected through a Zeiss Lyot filter with a passband of 0.025 nm.

  2. Changes of visual-field global indices after cataract surgery in primary open-angle glaucoma patients.

    Science.gov (United States)

    Seol, Bo Ram; Jeoung, Jin Wook; Park, Ki Ho

    2016-11-01

    To determine changes of visual-field (VF) global indices after cataract surgery and the factors associated with the effect of cataracts on those indices in primary open-angle glaucoma (POAG) patients. A retrospective chart review of 60 POAG patients who had undergone phacoemulsification and intraocular lens insertion was conducted. All of the patients were evaluated with standard automated perimetry (SAP; 30-2 Swedish interactive threshold algorithm; Carl Zeiss Meditec Inc.) before and after surgery. VF global indices before surgery were compared with those after surgery. The best-corrected visual acuity, intraocular pressure (IOP), number of glaucoma medications before surgery, mean total deviation (TD) values, mean pattern deviation (PD) value, and mean TD-PD value were also compared with the corresponding postoperative values. Additionally, postoperative peak IOP and mean IOP were evaluated. Univariate and multivariate logistic regression analyses were performed to identify the factors associated with the effect of cataract on global indices. Mean deviation (MD) after cataract surgery was significantly improved compared with the preoperative MD. Pattern standard deviation (PSD) and visual-field index (VFI) after surgery were similar to those before surgery. Also, mean TD and mean TD-PD were significantly improved after surgery. The posterior subcapsular cataract (PSC) type showed greater MD changes than did the non-PSC type in both the univariate and multivariate logistic regression analyses. In the univariate logistic regression analysis, the preoperative TD-PD value and type of cataract were associated with MD change. However, in the multivariate logistic regression analysis, type of cataract was the only associated factor. None of the other factors was associated with MD change. MD was significantly affected by cataracts, whereas PSD and VFI were not. Most notably, the PSC type showed better MD improvement compared with the non-PSC type after cataract surgery

  3. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    Science.gov (United States)

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  4. [Experimental study on the treatment of serious soft tissue injuries with strengthening the spleen and replenishing qi].

    Science.gov (United States)

    Chen, Xun-wen; Zhu, Yong-zhan; Chen, Zhi-wei; Wu, Zheng-jie; He, Li-lei

    2008-09-01

    To study the effects of Chinese drugs based on strengthening the spleen and replenishing qi treatment rule on neoformative capillaries and fibroblast during the soft tissue repair after serious trauma in rats, so as to explore the biological basis of the TCM theory "the spleen dominate extremities and muscles" applied to the treatment of soft tissue injuries. The model rats were established by bleeding from femoral artery and lancing method, and the rats were randomly divided into the control group, strengthening the spleen group and activating blood and resolving stasis group. The samples were got from the tissue of the wounded area at the 5th, 10th and 15th days after oral administration of the traditional Chinese medicine. After fixation and section, the tissues were stained by CD31 and PCNA staining. The amount of the capillaries and fibroblasts in the tissue of the wounded area were observed through multi-purpose microscope (ZEISS Axioskop2). Quantitative analysis was carried out on Image-ProPlus image analyzer. The amount of the capillaries and fibroblasts in the wounded tissue in the strengthening the spleen group were larger than that in the control group at the 5th, 10th and 15th day. And the proliferation speed of capillaries and fibroblasts was faster than those in the control group or the activating blood and resolving stasis group. The Chinese drugs according to strengthening the spleen and replenishing qi treatment rule were effective to promote growth of the granulation tissue and facilitate healing of the wounded area. And it has better effect than the treatment of promoting blood circulation and removing stasis.

  5. Objective measurement of intraocular forward light scatter using Hartmann-Shack spot patterns from clinical aberrometers. Model-eye and human-eye study.

    Science.gov (United States)

    Cerviño, Alejandro; Bansal, Dheeraj; Hosking, Sarah L; Montés-Micó, Robert

    2008-07-01

    To apply software-based image-analysis tools to objectively determine intraocular scatter determined from clinically derived Hartmann-Shack patterns. Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom, and Department of Optics, University of Valencia, Valencia, Spain. Purpose-designed image-analysis software was used to quantify scatter from centroid patterns obtained using a clinical Hartmann-Shack analyzer (WASCA, Zeiss/Meditec). Three scatter values, as the maximum standard deviation within a lenslet for all lenslets in the pattern, were obtained in 6 model eyes and 10 human eyes. In the model-eye sample, patterns were obtained in 4 sessions: 2 without realigning between measurements, 1 with realignment, and 1 with an angular shift of 6 degrees from the instrument axis. Three measurements were made in the human eyes with the C-Quant straylight meter (Oculus) to obtain psychometric and objective measures of retinal straylight. Analysis of variance, intraclass correlation coefficients, coefficient of repeatability (CoR), and correlations were used to determine intrasession and intersession repeatability and the relationship between measures. No significant differences were found between the sessions in the model eye (P=.234). The mean CoR was less than 10% in all model- and human-eye sessions. After incomplete patterns were removed, good correlation was achieved between psychometric and objective scatter measurements despite the small sample size (n=6; r=-0.831; P=.040). The methodology was repeatable in model and human eyes, strong against realignment and misalignment, and sensitive. Clinical application would benefit from effective use of the sensor's dynamic range.

  6. Irregularity of the posterior corneal surface during applanation using a curved femtosecond laser interface and microkeratome cutting head.

    Science.gov (United States)

    Vetter, Jan M; Holtz, Carsten; Vossmerbaeumer, Urs; Pfeiffer, Norbert

    2012-03-01

    To evaluate the irregularity of the posterior corneal surface and intrastromal dissection during the preparation of donor tissue for Descemet stripping automated endothelial keratoplasty (DSAEK) using a curved interface femtosecond laser and microkeratome. Sixteen human donor corneas unsuitable for transplantation were divided into two groups: a femtosecond (FS) laser group (n=7) using the VisuMax femtosecond laser (Carl Zeiss Meditec) and a microkeratome group (n=9) using the Amadeus II microkeratome (Ziemer Ophthalmic Group). The corneas were fixed on artificial anterior chambers. Horizontal cross-sections were obtained using spectral-domain optical coherence tomography prior to applanation, during applanation, as well as during and after intrastromal dissection at 450-μm corneal depth. The posterior surface and the dissection line were evaluated for irregularity by fitting a second-order polynomial curve using regression analysis and obtaining the root-mean-square error (RMSE). Groups were compared using analysis of variance. The RMSE of the posterior surface prior to applanation was 9.7 ± 3.1 μm in the FS laser group and 10.2 ± 2.3 μm in the microkeratome group. The RMSE increased to 50.7 ± 9.4 μm and 20.9 ± 6.1 μm during applanation and decreased again to 10.6 ± 1.4 μm and 8.1 ± 1.8 μm after applanation in the FS laser and microkeratome groups, respectively. The RMSE of the intrastromal cut was 19.5 ± 5.7 μm in the FS laser group and 7.7 ± 3.0 μm in the microkeratome group (P<.001). Our results show significantly greater irregularity with the curved interface femtosecond laser-assisted cleavage compared to microkeratome-assisted corneal dissection, possibly due to applanation-derived deformation of the posterior cornea. Copyright 2012, SLACK Incorporated.

  7. Microscopic Study of Surface Microtopographic Characteristics of Dental Implants

    Science.gov (United States)

    Sezin, M.; Croharé, L.; Ibañez, J.C.

    2016-01-01

    Objective: To determine and compare the micro topographic characteristics of dental implants submitted to different surface treatments, using scanning electron microscopy (SEM). Materials and Methods: Implants were divided into 7 groups of 3 specimens each, according to the surface treatment used: group 1: Osseotite, BIOMET 3i; group 2: SLA surface, Institut Straumann AG; group 3: Oxalife surface, Tree-Oss implant; group 4: B&W implant surface; group 5: Q-implant surface; group 6: ML implant surface; group 7: RBM surface, Rosterdent implant. The surfaces were examined under SEM (Carl Zeiss FE-SEM-SIGMA). Image Proplus software was used to determine the number and mean diameter of pores per area unit (mm). The data obtained were analyzed with the Mann-Whitney test. A confocal laser microscope (LEXT-OLS4100 Olympus) was used to conduct the comparative study of surface roughness (Ra). Data were analyzed using Tukey's HSD test. Results: The largest average pore diameter calculated in microns was found in group 5 (3.45 µm+/-1.91) while the smallest in group 7 (1.47µm+/-1.29). Significant differences were observed among each one of the groups studied (p<0.05). The largest number of pores/mm2 was found in group 2 (229343) and the smallest number in group 4 (10937). Group 2 showed significant differences regarding the other groups (p<0.05). The greatest roughness (Ra) was observed in group 2 (0.975µm+/-0.115) and the smallest in group 4 (0.304µm+/-0.063). Group 2 was significantly different from the other groups (p<0.05). Conclusion: The micro topography observed in the different groups presented dissimilar and specific features, depending on the chemical treatment used for the surfaces.. PMID:27335615

  8. Characterization of membranous (M) cells in normal feline conjunctiva-associated lymphoid tissue (CALT).

    Science.gov (United States)

    Giuliano, Elizabeth A; Finn, Kevin

    2011-09-01

    To characterize conjunctival lymphoid nodules obtained from the nictitans of healthy cats to determine if the follicle-associated epithelium (FAE) of conjunctiva-associated lymphoid tissue (CALT) in this species contains membranous (M)-cells analogous to those described in other regions of mucosa-associated lymphoid tissue (MALT). Lymphoid follicles from nictitan bulbar surfaces of 10 healthy cats (20 eyes total) were examined. Nictitans from five cats were harvested immediately post-mortem and a minimum of 12 lymphoid nodules from each third eyelid were isolated using a Zeiss operating microscope. At least three lymphoid follicles from each eye were examined using light microscopy (LM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) using standard fixation and embedding protocols. Nictitan-lymphoid follicles from another five healthy cats were processed for immunohistochemistry to characterize the distribution of T- and B-lymphocytes present beneath the FAE. The FAE overlying CALT from 10 healthy cats demonstrated morphology characteristic of M-cells including attenuated apical cell surface with blunted microvilli and microfolds, invaginated basolateral membrane forming a cytoplasmic pocket, and diminished distance between the apical and pocket membrane. Immunohistochemistry of lymphoid tissue subtending the FAE demonstrated B-cell dependent regions in the germinal centers surrounded by T-cell dependent interfollicular zones. Healthy feline CALT contains morphologic features analogous to those described in other regions of MALT. Documentation of feline conjunctival M-cells is of clinical relevance in the study of primary infectious, allergic, and autoimmune ocular diseases, as well as a potential means of vaccination or drug delivery. © 2011 American College of Veterinary Ophthalmologists.

  9. Markerless laser registration in image-guided oral and maxillofacial surgery.

    Science.gov (United States)

    Marmulla, Rüdiger; Lüth, Tim; Mühling, Joachim; Hassfeld, Stefan

    2004-07-01

    The use of registration markers in computer-assisted surgery is combined with high logistic costs and efforts. Markerless patient registration using laser scan surface registration techniques is a new challenging method. The present study was performed to evaluate the clinical accuracy in finding defined target points within the surgical site after markerless patient registration in image-guided oral and maxillofacial surgery. Twenty consecutive patients with different cranial diseases were scheduled for computer-assisted surgery. Data set alignment between the surgical site and the computed tomography (CT) data set was performed by markerless laser scan surface registration of the patient's face. Intraoral rigidly attached registration markers were used as target points, which had to be detected by an infrared pointer. The Surgical Segment Navigator SSN++ has been used for all procedures. SSN++ is an investigative product based on the SSN system that had previously been developed by the presenting authors with the support of Carl Zeiss (Oberkochen, Germany). SSN++ is connected to a Polaris infrared camera (Northern Digital, Waterloo, Ontario, Canada) and to a Minolta VI 900 3D digitizer (Tokyo, Japan) for high-resolution laser scanning. Minimal differences in shape between the laser scan surface and the surface generated from the CT data set could be detected. Nevertheless, high-resolution laser scan of the skin surface allows for a precise patient registration (mean deviation 1.1 mm, maximum deviation 1.8 mm). Radiation load, logistic costs, and efforts arising from the planning of computer-assisted surgery of the head can be reduced because native (markerless) CT data sets can be used for laser scan-based surface registration.

  10. [Microcytomorphometric video-image detection of nuclear chromatin in ovarian cancer].

    Science.gov (United States)

    Grzonka, Dariusz; Kamiński, Kazimierz; Kaźmierczak, Wojciech

    2003-09-01

    Technology of detection of tissue preparates precisious evaluates contents of nuclear chromatine, largeness and shape of cellular nucleus, indicators of mitosis, DNA index, ploidy, phase-S fraction and other parameters. Methods of detection of picture are: microcytomorphometry video-image (MCMM-VI), flow, double flow and activated by fluorescence. Diagnostic methods of malignant neoplasm of ovary are still nonspecific and not precise, that is a reason of unsatisfied results of treatment. Evaluation of microcytomorphometric measurements of nuclear chromatine histopathologic tissue preparates (HP) of ovarian cancer and comparison to normal ovarian tissue. Estimated 10 paraffin embedded tissue preparates of serous ovarian cancer, 4 preparates mucinous cancer and 2 cases of tumor Kruckenberg patients operated in Clinic of Perinatology and Gynaecology Silesian Medical Academy in Zabrze in period 2001-2002, MCMM-VI estimation based on computer aided analysis system: microscope Axioscop 20, camera tv JVCTK-C 1380, CarlZeiss KS Vision 400 rel.3.0 software. Following MCMM-VI parameters assessed: count of pathologic nucleus, diameter of nucleus, area, min/max diameter ratio, equivalent circle diameter (Dcircle), mean of brightness (mean D), integrated optical density (IOD = area x mean D), DNA index and 2.5 c exceeding rate percentage (2.5 c ER%). MCMM-VI performed on the 160 areas of 16 preparates of cancer and 100 areas of normal ovarian tissue. Statistical analysis was performed by used t-Student test. We obtained stastistically significant higher values parameters of nuclear chromatine, DI, 2.5 c ER of mucinous cancer and tumor Kruckenberg comparison to serous cancer. MCMM-VI parameters of chromatine malignant ovarian neoplasm were statistically significantly higher than normal ovarian tissue. Cytometric and karyometric parametres of nuclear chromatine estimated MCMM-VI are useful in the diagnostics and prognosis of ovarian cancer.

  11. SPECIES-SPECIFIC FOREST VARIABLE ESTIMATION USING NON-PARAMETRIC MODELING OF MULTI-SPECTRAL PHOTOGRAMMETRIC POINT CLOUD DATA

    Directory of Open Access Journals (Sweden)

    J. Bohlin

    2012-07-01

    Full Text Available The recent development in software for automatic photogrammetric processing of multispectral aerial imagery, and the growing nation-wide availability of Digital Elevation Model (DEM data, are about to revolutionize data capture for forest management planning in Scandinavia. Using only already available aerial imagery and ALS-assessed DEM data, raster estimates of the forest variables mean tree height, basal area, total stem volume, and species-specific stem volumes were produced and evaluated. The study was conducted at a coniferous hemi-boreal test site in southern Sweden (lat. 58° N, long. 13° E. Digital aerial images from the Zeiss/Intergraph Digital Mapping Camera system were used to produce 3D point-cloud data with spectral information. Metrics were calculated for 696 field plots (10 m radius from point-cloud data and used in k-MSN to estimate forest variables. For these stands, the tree height ranged from 1.4 to 33.0 m (18.1 m mean, stem volume from 0 to 829 m3 ha-1 (249 m3 ha-1 mean and basal area from 0 to 62.2 m2 ha-1 (26.1 m2 ha-1 mean, with mean stand size of 2.8 ha. Estimates made using digital aerial images corresponding to the standard acquisition of the Swedish National Land Survey (Lantmäteriet showed RMSEs (in percent of the surveyed stand mean of 7.5% for tree height, 11.4% for basal area, 13.2% for total stem volume, 90.6% for pine stem volume, 26.4 for spruce stem volume, and 72.6% for deciduous stem volume. The results imply that photogrammetric matching of digital aerial images has significant potential for operational use in forestry.

  12. Red Planet Mania: The Public Response to the 2003 Mars Opposition

    Science.gov (United States)

    Albin, E. F.; Dundee, D. A.

    2003-12-01

    Interest in Mars is at an all time high. For many weeks leading up to and after August 27th or, the date of opposition, record crowds flocked to observatories for a look at Mars. Even after the media "dropped" the event and moved on to other stories, the public response was still unusually strong. It is suggested that such an overwhelming public enthusiasm can be taken as good reason to seek a higher level of government funding for astronomy and the exploration of the Red Planet. Our observations and impressions of the public response to the close approach of Mars were taken from the authors affiliation with the Fernbank Science Center in Atlanta, Georgia - a museum which houses a well-equipped planetarium and observatory. The 500 seat planetarium features a Zeiss Mark V projector beneath a 21 meter diameter dome. A 0.9 meter reflecting telescope, situated not far from the planetarium, provided for stunning views of the Red Planet. Fernbank staff produced an original planetarium presentation entitled "Visions of Mars." Due to overflow crowds, special extended showings were offered. After the planetarium program, members of the public were invited to the observatory for a look at Mars. An average of approximately 120 people each hour looked through the telescope. On many evenings, centered around opposition, the observatory remained open from 9:00 p.m. until 5:30 a.m. the following morning. On each of these nights, we estimate that at least 950 people saw Mars through our telescope. An important tool, an Astrovid CCD video camera, was attached to a piggybacked 11-inch telescope. This instrument proved invaluable in preparing observers for their actual observation. Features such as a Polar Ice Cap, Syrtis Major, and Tharsis were easily identified on the TV monitor and then readily spotted through the telescope.

  13. Signal Normalization Reduces Image Appearance Disparity Among Multiple Optical Coherence Tomography Devices.

    Science.gov (United States)

    Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Schuman, Joel S

    2017-02-01

    To assess the effect of the previously reported optical coherence tomography (OCT) signal normalization method on reducing the discrepancies in image appearance among spectral-domain OCT (SD-OCT) devices. Healthy eyes and eyes with various retinal pathologies were scanned at the macular region using similar volumetric scan patterns with at least two out of three SD-OCT devices at the same visit (Cirrus HD-OCT, Zeiss, Dublin, CA; RTVue, Optovue, Fremont, CA; and Spectralis, Heidelberg Engineering, Heidelberg, Germany). All the images were processed with the signal normalization. A set of images formed a questionnaire with 24 pairs of cross-sectional images from each eye with any combination of the three SD-OCT devices either both pre- or postsignal normalization. Observers were asked to evaluate the similarity of the two displayed images based on the image appearance. The effects on reducing the differences in image appearance before and after processing were analyzed. Twenty-nine researchers familiar with OCT images participated in the survey. Image similarity was significantly improved after signal normalization for all three combinations ( P ≤ 0.009) as Cirrus and RTVue combination became the most similar pair, followed by Cirrus and Spectralis, and RTVue and Spectralis. The signal normalization successfully minimized the disparities in the image appearance among multiple SD-OCT devices, allowing clinical interpretation and comparison of OCT images regardless of the device differences. The signal normalization would enable direct OCT images comparisons without concerning about device differences and broaden OCT usage by enabling long-term follow-ups and data sharing.

  14. Detection of motion artifacts in optical coherence tomography using the fundus enhancement system

    International Nuclear Information System (INIS)

    Schaudig, U.; Skevas, C.; Scholz, F.

    2007-01-01

    Extensive artefacts due to major eye movements are detectable in optical coherence tomography images (OCT), but frequency and extent of small eye movements have not been studied. To investigate frequency and extent of irregularities in OCT imaging due to eye movements during the scanning process in OCT. A fundus enhancement system (FES) originally designed to improve retinal image quality in a conventional OCT device (Zeiss Stratus OCT) in order to integrate OCT images into fluorescence angiographies was used to record the scanning process and review OCT-scan acquisition in slow motion. A horizontal and a vertical single line scan of 5 mm length through the center of fixation were obtained in 40 eyes of 20 normal healthy subjects, all with a visual acuity of at least 20/20. Scans were investigated for loss of fixation and eye movements during the scanning process. Outcome measures were presence or absence of eye movements during the scanning process and mean deviation from the intended scan position, measured in millimeter. 7 of 20 patients showed no eye movements in both eyes. 4 of the remaining 13 patients showed eye movements only in one eye. In the eyes with detectable movements, the mean deviation from the intended scan position was 0.2 mm in the horizontal and 0.28 mm in the vertical scans. Fundus imaging in conventional systems can be enhanced to detect artifacts due to minimal eye movements during the scanning process. In this first series with normal healthy subjects, minimal eye movements were present in the over half of the investigations. Although the distances from the intended scan positions seem to be small in normal eyes, further investigations of the phenomenon are necessary. OCT is increasingly used as the primary tool for controlling therapy in macular diseases and the extent of motion artefacts is not known. (author) [de

  15. Clinical multiphoton FLIM tomography

    Science.gov (United States)

    König, Karsten

    2012-03-01

    This paper gives an overview on current clinical high resolution multiphoton fluorescence lifetime imaging in volunteers and patients. Fluorescence lifetime imaging (FLIM) in Life Sciences was introduced in Jena/Germany in 1988/89 based on a ZEISS confocal picosecond dye laser scanning microscope equipped with a single photon counting unit. The porphyrin distribution in living cells and living tumor-bearing mice was studied with high spatial, temporal, and spectral resolution. Ten years later, time-gated cameras were employed to detect dental caries in volunteers based on one-photon excitation of autofluorescent bacteria with long fluorescence lifetimes. Nowadays, one-photon FLIM based on picosecond VIS laser diodes are used to study ocular diseases in humans. Already one decade ago, first clinical twophoton FLIM images in humans were taken with the certified clinical multiphoton femtosecond laser tomograph DermaInspectTM. Multiphoton tomographs with FLIM modules are now operating in hospitals at Brisbane, Tokyo, Berlin, Paris, London, Modena and other European cities. Multiple FLIM detectors allow spectral FLIM with a temporal resolution down to 20 ps (MCP) / 250 ps (PMT) and a spectral resolution of 10 nm. Major FLIM applications include the detection of intradermal sunscreen and tattoo nanoparticles, the detection of different melanin types, the early diagnosis of dermatitis and malignant melanoma, as well as the measurement of therapeutic effects in pateints suffering from dermatitis. So far, more than 1,000 patients and volunteers have been investigated with the clinical multiphoton FLIM tomographs DermaInspectTM and MPTflexTM.

  16. The concave iris in pigment dispersion syndrome.

    Science.gov (United States)

    Liu, Lance; Ong, Ee Lin; Crowston, Jonathan

    2011-01-01

    To visualize the changes of the iris contour in patients with pigment dispersion syndrome after blinking, accommodation, and pharmacologic miosis using anterior segment optical coherence tomography. Observational case series. A total of 33 eyes of 20 patients with pigment dispersion syndrome. Each eye was imaged along the horizontal 0- to 180-degree meridian using the Visante Anterior Segment Imaging System (Carl Zeiss Meditec, Dublin, CA). Scans were performed at baseline and after focusing on an internal fixation target for 5 minutes, forced blinking, accommodation, and pharmacologic miosis with pilocarpine 2%. Quantitative analysis of the changes in the iris configuration. After 5 minutes of continual fixation, the iris became planar with the mean ± standard deviation curvature decreasing from 214 ± 74 μm to 67 ± 76 μm (P pigment dispersion syndrome after forced blinking, but the iris concavity recovered to 227 ± 113 μm (P = 0.34) and 238 ± 119 μm (P = 0.19) with the -3.0 and -6.0 diopter lenses, respectively. Pilocarpine-induced miosis caused the iris to assume a planar configuration in all subjects. This study shows that the iris in pigment dispersion syndrome assumes a planar configuration when fixating and that the concavity of the iris surface is not restored by blinking. Accommodation restored the iris concavity, suggesting that the posterior curvature of the iris in pigment dispersion syndrome is induced and probably maintained, at least in part, by accommodation. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Iris colour in relation to myopia among Chinese school-aged children.

    Science.gov (United States)

    Pan, Chen-Wei; Qiu, Qin-Xiao; Qian, Deng-Juan; Hu, Dan-Ning; Li, Jun; Saw, Seang-Mei; Zhong, Hua

    2018-01-01

    Understanding the association of iris colour and myopia may provide further insights into the role of the wavelength of lights in the pathophysiology of myopia. We aim to assess the association of iris colour and myopia in a school-based sample of Chinese students. Two thousand three hundred and forty-six Year 7 students from 10 middle schools (93.5% response rate) aged 13-14 years in Mojiang, a small county located in Southwestern China, participated in the study. We obtained standardised slit lamp photographs and developed a grading system assessing iris colour (higher grade denoting a darker iris). Refractive error was measured after cycloplegia using an autorefractor by optometrists or trained technicians. An IOLMaster (www.zeiss.com) was used to measure ocular biometric parameters including axial length (AL). Of all the study participants, 693 (29.5%) were affected by myopia with the prevalence estimates being higher in girls (36.8%; 95% confidence interval [CI]: 34.0, 39.6) than in boys (22.8%; 95% CI: 20.4, 25.1) (p iris colour tended to have a higher prevalence of myopia, a more myopic refraction and a longer AL. Dose-response relationships were observed in all regression models (p for trend iris colour was associated with more myopic refractive errors and longer ALs among Chinese school-aged children and this association was independent of other known myopia-related risk factors. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  18. In Vitro Comparative Study of Oxygen Plasma Treated Poly(Lactic⁻Co⁻Glycolic) (PLGA) Membranes and Supported Nanostructured Oxides for Guided Bone Regeneration Processes.

    Science.gov (United States)

    Torres-Lagares, Daniel; Castellanos-Cosano, Lizett; Serrera-Figallo, Maria-Angeles; López-Santos, Carmen; Barranco, Angel; Rodríguez-González-Elipe, Agustín; Gutierrez-Perez, Jose-Luis

    2018-05-08

    (1) Background: The use of physical barriers to prevent the invasion of gingival and connective tissue cells into bone cavities during the healing process is called guided bone regeneration. The objective of this in-vitro study was to compare the growth of human osteoblasts on Poly(Lactic⁻co⁻Glycolic) (PLGA) membranes modified with oxygen plasma and Hydroxyapatite (HA), silicon dioxide (SiO₂), and titanium dioxide (TiO₂) composite nanoparticles, respectively. (2) Methods: All the membranes received a common treatment with oxygen plasma and were subsequently treated with HA nanostructured coatings (n = 10), SiO₂ (n = 10) and TiO₂ (n = 10), respectively and a PLGA control membrane (n = 10). The assays were performed using the human osteoblast line MG-63 acquired from the Center for Scientific Instrumentation (CIC) from the University of Granada. The cell adhesion and the viability of the osteoblasts were analyzed by means of light-field microphotographs of each condition with the inverted microscope Axio Observer A1 (Carl Zeiss). For the determination of the mitochondrial energy balance, the MitoProbe™ JC-1 Assay Kit was employed. For the determination of cell growth and the morphology of adherent osteoblasts, two techniques were employed: staining with phalloidin-TRITC and staining with DAPI. (3) Results: The modified membranes that show osteoblasts with a morphology more similar to the control osteoblasts follow the order: PLGA/PO₂/HA > PLGA/PO₂/SiO₂ > PLGA/PO₂/TiO₂ > PLGA ( p membranes was observed as follows: PLGA/PO₂/SiO₂ > PLGA/PO₂/HA > PLGA/PO₂/TiO₂ > PLGA ( p membranes PLGA/PO₂/HA and PLGA/PO₂/SiO₂. (4) Conclusion: The membrane in which osteoblasts show characteristics more similar to the control osteoblasts is the PLGA/PO₂/HA, followed by the PLGA/PO₂/SiO₂.

  19. Wolfram Sendromlu Hastalarda Optik Koherans Tomografi Bulguları

    Directory of Open Access Journals (Sweden)

    Bengü Ekinci Köktekir

    2014-05-01

    Full Text Available Objectives: To report the optical coherence tomography (OCT findings in patients with Wolfram syndrome. Materials and Methods: Four patients who fulfilled the criteria for Wolfram syndrome were recruited to the study. In all patients, OCT was performed with Stratus OCT (OCT-3, Carl Zeiss Meditec, Inc. Germany. The fast retinal nerve fiber layer (RNFL and fast macular thickness protocols were used to measure the RNFL and macular thickness, respectively. The fast optic disc protocol was used to determine the cup-to-disc ratios of the optic disc. All patients were examined with VEP (Retimax, CSO Strumenti Oftalmici, Florence, Italy. Results: In eight eyes of four patients (3 male and 1 female with a mean age of 18.5±2.08 years (range 16-21 years, RNFL, macular thickness, and cup-to-disc ratios were determined. The mean RNFL was 42.2±5.6 µm (range 34.1-49.5 µm, while the mean macular thickness and cup-to-disc ratios were 145±15 µm (range 125-160 µm and 0.79±0.07 (range 0.7-0.92, respectively. There was a moderate negative correlation between VEP latencies and macular and RNFL thicknesses (Spearman correlation coefficient was -0.23 and -0.34, respectively. Conclusions: RNFL loss and secondary optical atrophy are severe complications that may affect the visual acuity in patients with Wolfram syndrome. Retinal changes in these patients may be quantified and can be observed using OCT. (Turk J Ophthalmol 2014; 44: 212-5

  20. Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth

    Directory of Open Access Journals (Sweden)

    Jinhai Huang

    2016-01-01

    Full Text Available Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA for measuring central corneal thickness (CCT, anterior chamber depth (ACD, and aqueous depth (AD. Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator. Agreement between the two devices was assessed using paired t-tests, Bland-Altman plots, and 95% limits of agreement (LoA. Results. The mean CCT, ACD, and AD measured by AL-Scan were 538.59±27.37 μm, 3.70±0.30 mm, and 3.16±0.30 mm, respectively. The mean values obtained by the Visante OCT were 536.14±26.61 μm for CCT, 3.71±0.29 mm for ACD, and 3.17±0.29 mm for AD. The mean CCT by the AL-Scan was higher than that obtained by the Visante AS-OCT (difference = 2.45±6.07 μm, P<0.05. The differences in ACD and AD measurements were not statistically significant. The 95% LoA of CCT, ACD, and AD were between −9.44 and 14.35 μm, −0.15 and 0.12 mm, and −0.15 and 0.12 mm, respectively. Conclusions. Since these two devices were comparable for measuring CCT, ACD, and AD, their results can be interchangeably used in the clinic.

  1. Comparison and interchangeability of macular thickness measured with Cirrus OCT and Stratus OCT in myopic eyes

    Directory of Open Access Journals (Sweden)

    Geng Wang

    2015-12-01

    Full Text Available AIM: To investigate the difference of macular thickness measurements between stratus optical coherence tomography (OCT and Cirrus OCT (Carl Zeiss Meditec, Dublin, CA, USA in the same myopic patient and to develop a conversion equation to interchange macular thickness obtained with these two OCT devices. METHODS: Eighty-nine healthy Chinese adults with spherical equivalent (SE ranging from -1.13 D to -9.63 D were recruited. The macular thickness was measured by Cirrus OCT and Stratus OCT. The correlation between macular thickness and axial length and the agreement between two OCT measurements were evaluated. A formula was generated to interchange macular thickness obtained with two OCT devices. RESULTS: Average macular thickness measured with Stratus OCT (r=-0.280, P=0.008 and Cirrus OCT (r=-0.224, P=0.034 were found to be negatively correlated with axial length. No statistically significant correlation was found between axial length and central subfield macular thickness (CMT measured with Stratus OCT (r=0.191, P=0.073 and Cirrus OCT (r=0.169, P=0.113. The mean CMT measured with Cirrus OCT was 53.63±7.94 μm thicker than with Stratus OCT. The formula CMTCirrus OCT=78.328+0.874×CMTStratus OCT was generated to interchange macular thickness obtained with two OCT devices. CONCLUSION: Macular thickness measured with Cirrus OCT were thicker than with Stratus OCT in myopic eyes. A formula can be used to interchange macular thickness measured with two OCT devices in myopic eyes. Studies with different OCT devices and larger samples are warranted to enable the comparison of macular values measured with different OCT devices.

  2. Pulsed Light Accelerated Crosslinking versus Continuous Light Accelerated Crosslinking: One-Year Results

    Directory of Open Access Journals (Sweden)

    Cosimo Mazzotta

    2014-01-01

    Full Text Available Purpose. To compare functional results in two cohorts of patients undergoing epithelium-off pulsed (pl-ACXL and continuous light accelerated corneal collagen crosslinking (cl-ACXL with dextran-free riboflavin solution and high-fluence ultraviolet A irradiation. Design. It is a prospective, comparative, and interventional clinical study. Methods. 20 patients affected by progressive keratoconus were enrolled in the study. 10 eyes of 10 patients underwent an epithelium-off pl-ACXL by the KXL UV-A source (Avedro Inc., Waltham, MS, USA with 8 minutes (1 sec. on/1 sec. off of UV-A exposure at 30 mW/cm2 and energy dose of 7.2 J/cm2; 10 eyes of 10 patients underwent an epithelium-off cl-ACXL at 30 mW/cm2 for 4 minutes. Riboflavin 0.1% dextran-free solution was used for a 10-minutes corneal soaking. Patients underwent clinical examination of uncorrected distance visual acuity and corrected distance visual acuity (UDVA and CDVA, corneal topography and aberrometry (CSO EyeTop, Florence, Italy, corneal OCT optical pachymetry (Cirrus OCT, Zeiss Meditec, Jena, Germany, endothelial cells count (I-Conan Non Co Robot, and in vivo scanning laser confocal microscopy (Heidelberg, Germany at 1, 3, 6, and 12 months of follow-up. Results. Functional results one year after cl-ACXL and pl-ACXL demonstrated keratoconus stability in both groups. Functional outcomes were found to be better in epithelium-off pulsed light accelerated treatment together with showing a deeper stromal penetration. No endothelial damage was recorded during the follow-up in both groups. Conclusions. The study confirmed that oxygen represents the main driver of collagen crosslinking reaction. Pulsed light treatment optimized intraoperative oxygen availability improving postoperative functional outcomes compared with continuous light treatment.

  3. Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema.

    Science.gov (United States)

    Forooghian, Farzin; Cukras, Catherine; Meyerle, Catherine B; Chew, Emily Y; Wong, Wai T

    2008-10-01

    To evaluate macular thickness and volume measurements and their intrasession repeatability in two optical coherence tomography (OCT) systems: the Stratus OCT, a time domain system, and the Cirrus HD-OCT, a spectral domain system (both by Carl Zeiss Meditec, Inc., Dublin, CA), in the context of diabetic macular edema (DME). Thirty-three eyes of 33 diabetic patients with clinically significant macular edema (CSME) were scanned in a single session by a single operator on both OCT systems. Macular thickness measurements of nine standard macular subfields and total macular volume were obtained and analyzed. Bland-Altman plots were constructed to assess agreement in macular measurements. Intraclass correlation coefficients (ICCs), coefficients of repeatability (CR(W)), and coefficients of variation (CV(W)) were used to assess intrasession repeatability. Macular thickness in nine retinal subfields and macular volume were significantly higher in the Cirrus HD-OCT system compared with the Stratus OCT system. Subfield thickness and total volume measurements, respectively, were 30 to 55 microm and 3.2 mm(3) greater for the Cirrus HD-OCT system compared with the Stratus OCT system. Both Stratus OCT and Cirrus HD-OCT systems demonstrated high intrasession repeatability, with overlapping ranges for CR(W), CV(W), and ICC. Repeatability measures (CR(W) and CV(W)) differed significantly between systems in only one of nine subfields (outer temporal subfield). Absolute measures of macular thickness and volume in patients with DME differed significantly in magnitude between the Stratus OCT and Cirrus HD-OCT systems. However, both OCT systems demonstrated high intrasessional repeatability. Although the two systems may not be used interchangeably, they appear equally reliable in generating macular measurements for clinical practice and research.

  4. [Visual outcomes 5 years after small incision lenticule extraction (SMILE), surgery on spherocylindrical myopia eyes, from 616 eyes].

    Science.gov (United States)

    Burazovitch, J; Ferguene, H; Naguszewski, D

    2018-05-15

    Determine if the visual criteria of the technique of surgery refractive by Femtosecond Laser-assisted duckweed Extraction - Small Lenticule Extraction (FLEx-Smile ® ), realized in the laser femtosecond VisuMax ® (Carl Zeiss Meditec, Jena, Germany), are stable, secure, effective and predictable in the long term, to the nearsighted and astigmatic. Retrospective study, monocentric with data collected between March 2012 and March 2017. The study included 616 eyes of 309 nearsighted and astigmatic patients (spherical equivalent from 1 to 11 D). They were followed in postoperative immediate (D+1), in 3 months, in 1 year and in 5 years. The taken measures include the refraction, the uncorrected visual acuteness (UVAC) and the best visual corrected acuteness (BVAC). The criteria of evaluation were based on the BVAC, the refractive stability, the index of security (IS: MAVC to preoperative D+1/BVAC before operation) and the predictability (percentage of eyes in±1 D of SE target). UVAC was better 5th year than after the intervention (P=0.001) and 88% of the operated eyes had an UVAC in 8/10 (logMAR=0.1). For the stability refractive, the patients became nearsighted between the intervention and 5th year (P=0.001), with a regression of 0.240 D. The indication of safety was better 5th year than the day after the intervention (P=0.001), 92% of eyes operated in 5 years were 0.5 D of SE target and 77% of eyes had lost no line. SMILE is a good technique of surgery refractive stable, secure, effective and predictable on the long term. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  5. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    Science.gov (United States)

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  6. [Three Years Follow-up Study after Refractive Small Incision Lenticule Extraction (SMILE) Using 500 kHz Femtosecond Laser in "Fast Mode"].

    Science.gov (United States)

    Messerschmidt-Roth, A; Sekundo, W; Lazaridis, A; Schulze, S

    2017-01-01

    Background   The aim of this clinical trial was to check the results of laser built-in settings 3 years after ReLEx SMILE for moderate and high myopia in unselected "real life" patients. Patients and Methods   50 myopic eyes of 27 patients were called in for examination after 3 years. 25 of these eyes with a preoperative myopia under - 6D comprised the "moderate myopia subgroup". All surgeries were performed with the 500 kHz VisuMax® femtosecond laser (Carl Zeiss Meditec AG, Jena) in the "fast mode" setting. Results   The spherical equivalent (SE) of the entire group changed from - 6.18 D (± 1.91) prior to surgery to - 0.18 D (± 0.39) 3 years later. The preoperative SE in the moderate myopia subgroup changed from - 4.71 D (± 0.94) to - 0.04 D (± 0.23). 14 % of 50 eyes gained one line and 22 % lost one line of CDVA. The regression between month 3 and 36 was 0.07D for the entire group and 0.06 D for the moderate myopia subgroup. There were no late side effects. Primary undercorrection was predominantly seen in eyes over - 6 D. Conclusion   ReLEx SMILE shows remarkable stability over the entire range of myopias after 3 years, however primary undercorrection occurs predominantly in eyes of - 6.0 D, which necessitates nomogram adjustment. Georg Thieme Verlag KG Stuttgart · New York.

  7. One-year refractive results, contrast sensitivity, high-order aberrations and complications after myopic small-incision lenticule extraction (ReLEx SMILE).

    Science.gov (United States)

    Sekundo, Walter; Gertnere, Jana; Bertelmann, Thomas; Solomatin, Igor

    2014-05-01

    To report one year results of the first cohort of routine refractive lenticule extraction through a small incision (ReLEx SMILE) for correction of myopia and myopic astigmatism. Fifty-four eyes of 27 patients with spherical equivalent of -4.68 ± 1.29D who underwent routine ReLEx SMILE by a single surgeon were prospectively followed-up for 1 year. We used the VisuMax femtosecond laser system (Carl Zeiss Meditec AG, Germany) with a 500 kHz repetition rate. Folow-up intervals were at 1 day, 1 week, 1, 3, 6, and 12 months after surgery. We obtained following parameters: uncorrected (UDVA) and distance-corrected visual acuity (CDVA), contrast sensitivity, and wave front measurements. We also recorded all complications. Because of suction loss in one eye, 12-month results were obtained in 53 eyes as follows. After 1 year, 88% of eyes with plano target had an UDVA of 20/20 or better. Twelve percent of eyes lost 1 line of CDVA, while 31% gained 1 line and 3% gained 2 lines. The mean SE after 1 year was -0.19 ± 0.19. The mean refraction change between month 1 and 12 was 0.08 D. Neither mesopic nor photopic contrast sensitivity showed any significant changes. The high-order aberrations (HOA) increased from 0.17 to 0.27 μm (Malacara notation). No visually threatening complications were observed. In this first cohort, ReLEx SMILE produced satisfactory refractive outcomes with moderate induction of HOA and unaffected contrast sensitivity after 1 year.

  8. Technical Note: Effect of explicit M and N-shell atomic transitions on a low-energy x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Peter G. F., E-mail: peter.watson@mail.mcgill.ca; Seuntjens, Jan [Medical Physics Unit, McGill University, Montreal, Quebec H4A 3J1 (Canada)

    2016-04-15

    Purpose: In EGSnrc, atomic transitions to and from the M and N-shells are treated in an average way by default. This approach is justified in which the energy difference between explicit and average M and N-shell binding energies is less than 1 keV, and for most applications can be considered negligible. However, for simulations of low energy x-ray sources on thin, high-Z targets, characteristic x-rays can make up a significant portion of the source spectra. As of release V4-2.4.0, EGSnrc has included an option to enable a more complete algorithm of all atomic transitions available in the EADL compilation. In this paper, the effect of M and N-shell averaging on the calculation of half-value layer (HVL) and relative depth dose (RDD) curve of a 50 kVp intraoperative x-ray tube with a thin gold target was investigated. Methods: A 50 kVp miniature x-ray source with a gold target (The INTRABEAM System, Carl Zeiss, Germany) was modeled with the EGSnrc user code cavity, both with and without M and N-shell averaging. From photon fluence spectra simulations, the source HVLs were determined analytically. The same source model was then used with egs-chamber to calculate RDD curves in water. Results: A 4% increase of HVL was reported when accounting for explicit M and N-shell transitions, and up to a 9% decrease in local relative dose for normalization at 3 mm depth in water. Conclusions: The EGSnrc default of using averaged M and N-shell binding energies has an observable effect on the HVL and RDD of a low energy x-ray source with high-Z target. For accurate modeling of this class of devices, explicit atomic transitions should be included.

  9. Automated Microscopy: Macro Language Controlling a Confocal Microscope and its External Illumination: Adaptation for Photosynthetic Organisms.

    Science.gov (United States)

    Steinbach, Gábor; Kaňa, Radek

    2016-04-01

    Photosynthesis research employs several biophysical methods, including the detection of fluorescence. Even though fluorescence is a key method to detect photosynthetic efficiency, it has not been applied/adapted to single-cell confocal microscopy measurements to examine photosynthetic microorganisms. Experiments with photosynthetic cells may require automation to perform a large number of measurements with different parameters, especially concerning light conditions. However, commercial microscopes support custom protocols (through Time Controller offered by Olympus or Experiment Designer offered by Zeiss) that are often unable to provide special set-ups and connection to external devices (e.g., for irradiation). Our new system combining an Arduino microcontroller with the Cell⊕Finder software was developed for controlling Olympus FV1000 and FV1200 confocal microscopes and the attached hardware modules. Our software/hardware solution offers (1) a text file-based macro language to control the imaging functions of the microscope; (2) programmable control of several external hardware devices (light sources, thermal controllers, actuators) during imaging via the Arduino microcontroller; (3) the Cell⊕Finder software with ergonomic user environment, a fast selection method for the biologically important cells and precise positioning feature that reduces unwanted bleaching of the cells by the scanning laser. Cell⊕Finder can be downloaded from http://www.alga.cz/cellfinder. The system was applied to study changes in fluorescence intensity in Synechocystis sp. PCC6803 cells under long-term illumination. Thus, we were able to describe the kinetics of phycobilisome decoupling. Microscopy data showed that phycobilisome decoupling appears slowly after long-term (>1 h) exposure to high light.

  10. Mapping microscopic order in plant and mammalian cells and tissues: novel differential polarization attachment for new generation confocal microscopes (DP-LSM)

    International Nuclear Information System (INIS)

    Steinbach, G; Pawlak, K; Garab, G; Pomozi, I; Tóth, E A; Molnár, A; Matkó, J

    2014-01-01

    Elucidation of the molecular architecture of complex, highly organized molecular macro-assemblies is an important, basic task for biology. Differential polarization (DP) measurements, such as linear (LD) and circular dichroism (CD) or the anisotropy of the fluorescence emission (r), which can be carried out in a dichrograph or spectrofluorimeter, respectively, carry unique, spatially averaged information about the molecular organization of the sample. For inhomogeneous samples—e.g. cells and tissues—measurements on macroscopic scale are not satisfactory, and in some cases not feasible, thus microscopic techniques must be applied. The microscopic DP-imaging technique, when based on confocal laser scanning microscope (LSM), allows the pixel by pixel mapping of anisotropy of a sample in 2D and 3D. The first DP-LSM configuration, which, in fluorescence mode, allowed confocal imaging of different DP quantities in real-time, without interfering with the ‘conventional’ imaging, was built on a Zeiss LSM410. It was demonstrated to be capable of determining non-confocally the linear birefringence (LB) or LD of a sample and, confocally, its FDLD (fluorescence detected LD), the degree of polarization (P) and the anisotropy of the fluorescence emission (r), following polarized and non-polarized excitation, respectively (Steinbach et al 2009 Acta Histochem.111 316–25). This DP-LSM configuration, however, cannot simply be adopted to new generation microscopes with considerably more compact structures. As shown here, for an Olympus FV500, we designed an easy-to-install DP attachment to determine LB, LD, FDLD and r, in new-generation confocal microscopes, which, in principle, can be complemented with a P-imaging unit, but specifically to the brand and type of LSM. (paper)

  11. Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 06: Investigation of an absorbed dose to water formalism for a miniature low-energy x-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Peter; Seuntjens, Jan [McGill University, Cedars Cancer Centre (Canada)

    2016-08-15

    Purpose: We present a formalism for calculating the absorbed dose to water from a miniature x-ray source (The INTRABEAM system, Carl Zeiss), using a parallel-plate ionization chamber calibrated in terms of air-kerma. Monte Carlo calculations were performed to derive a chamber conversion factor (C{sub Q}) from reference air-kerma to dose to water for the INTRABEAM. C{sub Q} was investigated as a function of depth in water, and compared with the manufacturer’s reported value. The effect of chamber air cavity dimension tolerance was also investigated. Methods: Air-kerma (A{sub k}) from a reference beam was calculated using the EGSnrc user code cavity. Using egs-chamber, a model of a PTW 34013 parallel-plate ionization chamber was created according to manufacturer specifications. The dose to the chamber air cavity (D{sub gas}) was simulated both in-air (with reference beam) and in-water (with INTRABEAM source). Dose to a small water voxel (D{sub w}) was also calculated. C{sub Q} was derived from these quantities. Results: C{sub Q} was found to vary by up to 15% (1.30 vs 1.11) between chamber dimension extremes. The agreement between chamber C{sub Q} was found to improve with increasing depth in water. However, in all cases investigated, C{sub Q} was larger than the manufacturer reported value of 1.054. Conclusions: Our results show that cavity dimension tolerance has a significant effect on C{sub Q}, with differences as large as 15%. In all cases considered, C{sub Q} was found to be larger than the reported value of 1.054. This suggests that the recommended calculation underestimates the dose to water.

  12. Comparison of biometric predictability and final refraction expected in phacoemulsification surgery with and without trabeculectomy

    Directory of Open Access Journals (Sweden)

    Fernanda Guedes Oliveira

    Full Text Available Abstract Objective: The main purpose of this article is to compare the predictability of biometric results and final refractive outcomes expected in patients undergoing cataract surgery through phacoemulsification with and without associated trabeculectomy. Methods: Cataract patients who have undergone phacoemulsification surgery alone (control group or associated with trabeculectomy (study group screened. All surgeries were performed following standard protocol. For enrollment, biometrics calculated by IOL Master (Carl Zeiss Meditec, Inc. biometry, refraction and intraocular pressure (IOP before and after surgery were required. Data was compared between groups in addition to the correlation between variation of IOP and final refraction. Results: Thirty eyes per group were enrolled. Only prior IOP (p <0.001, IOP post-surgery (p = 0.01 and the difference in IOP (p <0.001 were statistically significant. Axial length, IOL diopter used, expected spherical refraction by biometrics and astigmatism pre- and post-surgery were similar in both groups (p=0.1; 0.4; 0.4; 0.5 and 0.3, respectively. Spherical predictability by biometrics within 0.25 diopters was noted in both the control group (range 0.06 ± 0.45 and study group (range 0.25 ± 0.97, p = 0.3. There was no statistical significance between groups for the difference between final cylinder and corneal astigmatism (p = 0.9, and the difference between axis of refractive and corneal astigmatism (p = 0.7. Conclusion: The biometric predictability in phacoemulsification surgery and the expected final refraction are significant, andare not modified by trabeculectomy in the combined surgeries.

  13. Sensitivity and specificity of machine learning classifiers and spectral domain OCT for the diagnosis of glaucoma.

    Science.gov (United States)

    Vidotti, Vanessa G; Costa, Vital P; Silva, Fabrício R; Resende, Graziela M; Cremasco, Fernanda; Dias, Marcelo; Gomi, Edson S

    2012-06-15

    Purpose. To investigate the sensitivity and specificity of machine learning classifiers (MLC) and spectral domain optical coherence tomography (SD-OCT) for the diagnosis of glaucoma. Methods. Sixty-two patients with early to moderate glaucomatous visual field damage and 48 healthy individuals were included. All subjects underwent a complete ophthalmologic examination, achromatic standard automated perimetry, and RNFL imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, California, USA). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters. Subsequently, the following MLCs were tested: Classification Tree (CTREE), Random Forest (RAN), Bagging (BAG), AdaBoost M1 (ADA), Ensemble Selection (ENS), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Naive-Bayes (NB), and Support Vector Machine (SVM). Areas under the ROC curves (aROCs) obtained for each parameter and each MLC were compared. Results. The mean age was 57.0±9.2 years for healthy individuals and 59.9±9.0 years for glaucoma patients (p=0.103). Mean deviation values were -4.1±2.4 dB for glaucoma patients and -1.5±1.6 dB for healthy individuals (pposition (0.765), and 6 o'clock position (0.754). The aROCs from classifiers varied from 0.785 (ADA) to 0.818 (BAG). The aROC obtained with BAG was not significantly different from the aROC obtained with the best single SD-OCT parameter (p=0.93). Conclusions. The SD-OCT showed good diagnostic accuracy in a group of patients with early glaucoma. In this series, MLCs did not improve the sensitivity and specificity of SD-OCT for the diagnosis of glaucoma.

  14. Automated hotspot analysis with aerial image CD metrology for advanced logic devices

    Science.gov (United States)

    Buttgereit, Ute; Trautzsch, Thomas; Kim, Min-ho; Seo, Jung-Uk; Yoon, Young-Keun; Han, Hak-Seung; Chung, Dong Hoon; Jeon, Chan-Uk; Meyers, Gary

    2014-09-01

    Continuously shrinking designs by further extension of 193nm technology lead to a much higher probability of hotspots especially for the manufacturing of advanced logic devices. The CD of these potential hotspots needs to be precisely controlled and measured on the mask. On top of that, the feature complexity increases due to high OPC load in the logic mask design which is an additional challenge for CD metrology. Therefore the hotspot measurements have been performed on WLCD from ZEISS, which provides the benefit of reduced complexity by measuring the CD in the aerial image and qualifying the printing relevant CD. This is especially of advantage for complex 2D feature measurements. Additionally, the data preparation for CD measurement becomes more critical due to the larger amount of CD measurements and the increasing feature diversity. For the data preparation this means to identify these hotspots and mark them automatically with the correct marker required to make the feature specific CD measurement successful. Currently available methods can address generic pattern but cannot deal with the pattern diversity of the hotspots. The paper will explore a method how to overcome those limitations and to enhance the time-to-result in the marking process dramatically. For the marking process the Synopsys WLCD Output Module was utilized, which is an interface between the CATS mask data prep software and the WLCD metrology tool. It translates the CATS marking directly into an executable WLCD measurement job including CD analysis. The paper will describe the utilized method and flow for the hotspot measurement. Additionally, the achieved results on hotspot measurements utilizing this method will be presented.

  15. Incidence of cholesterol in periapical biopsies among adolescent and elderly patients.

    Science.gov (United States)

    Slutzky-Goldberg, Iris; Baev, Valery; Volkov, Alexander; Zini, Avi; Tsesis, Igor

    2013-12-01

    Cholesterol clefts are common histologic findings in periapical biopsies; they have a reported incidence in periapical periodontitis of up to 44%. Cholesterol crystals are also recognized in advanced atherosclerotic plaques in humans. Male sex, genetic abnormalities, and age have been associated with advanced atherosclerotic lesions. Among these nonmodifiable risk factors, age is the most dominant. The aim of the study was to evaluate if age is also linked to cholesterol deposition in periapical periodontitis. The database of biopsy reports obtained between 2006 and 2009 was searched for specimens diagnosed as radicular cysts or periapical granulomas. Only data relating to biopsies obtained from adolescent (13-21 years old) and elderly (over 60 years old) patients were selected. The biopsies were examined by a pathologist under a light microscope (Zeiss, Jena, Germany) at magnifications of 40×-200×. The available material was scanned for the presence of cholesterol clefts and foamy cells in radicular cysts and granulomas. A total of 41 specimens were collected in the adolescent group and 48 specimens in the elderly group over a 4-year period. A higher incidence of cholesterol was found in the elderly group compared with that in the adolescent group (odds ratio = 6.857). The highly significant incidence of cholesterol deposits in periapical biopsies among elderly patients may be a possible cause for the lack of repair. The mechanism for cholesterol accumulation is probably similar to the process leading to atherosclerosis and coronary artery disease. Statin administration may be advantageous for the treatment of persistent lesions. A clinician should be aware of the risk for persistent lesions after endodontic treatment in elderly patients. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Quantitative EDX microanalysis of Bi2Te3 in the TEM

    International Nuclear Information System (INIS)

    Peranio, N.; Eibl, O.

    2007-01-01

    Quantitative chemical analysis by energy dispersive X-ray spectrometry (EDX) in a transmission electron microscope (TEM) Zeiss912 and ohm; was applied to p-type (Bi,Sb) 2 Te 3 and n-type Bi 2 (Te,Se) 3 thermoelectric materials. Preliminary results yielded artifacts due to Bi spurious X-rays and hole-counts significantly beyond zero. A stray aperture was inserted in the TEM to absorb the stray radiation. With this aperture inserted a high-accuracy quantitative chemical analysis was established. The hole-counts decreased by a factor of 5 and the scatter of data decreased by a factor of 4 with respect to no aperture inserted. The mole fractions of Te and Se were 54.4 at% and 5.5 at% and varied by 0.5 at% for n-type material. A similar behaviour was found for Sb and Bi in p-type material. The variation in stoichiometry is smaller on the sub-micrometer scale and increases with increasing length scale for both, n-type and p-type Bi 2 Te 3 . Measurements in the TEM confirmed the inhomogeneous chemical composition found by wavelength dispersive X-ray spectrometry. The improved accuracy of the quantitative EDX analysis is also important for other compounds with unique physical properties. This was demonstrated on thin foils containing heavy elements and on powders of light elements dispersed on Cu-grids, i.e., the high-T C superconductor Bi 2 Sr 2 CaCu 2 O 8 and the mineral salt hydroxyapatite Ca 10 (PO 4 ) 6 OH 2 . (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Latest developments on EUV reticle and pellicle research and technology at TNO

    Science.gov (United States)

    Verberk, Rogier; Koster, Norbert; te Sligte, Edwin; Staring, Wilbert

    2017-06-01

    At TNO an extensive EUV optics life time program has been running for over 15 years together with our partners ASML and Carl Zeiss. This has contributed to the upcoming introduction of EUV High Volume Manufacturing (HVM). To further help the industry with the introduction of EUV, TNO has worked on extending their facilities with a number of reticle and pellicle research infrastructure facilities. In this paper we will show some of the facilities that are available at TNO and shortly introduce their capabilities. Recently we have opened our EBL2 facility, which is an EUV Beam Line (EBL2) meant for studying the effects of high power EUV illumination on optics, reticles and pellicles up to the power roadmap of 500 W at intermediate Focus (IF). This facility is open to users from all over the world and is beneficial for the industry in helping developing alternative capping layers and contamination control strategies for optics lifetime, new absorber materials, pellicles and resists. The EBL2 system has seen first light in December 2016 and is now in the final stage of acceptance testing and qualification. It is expected that the system will be fully operational in the third quarter of 2017, and available for users. It is possible to transfer reticles to and from the EBL2 by means of the reticle handler using the dual pod interface. This secures backside cleanliness to NXE standards and thus enables wafer printing on a NXE tool in a later stage after the exposures and inspection at EBL2. Besides EBL2, a high performance and ultra-clean reticle handler is available at TNO. This handler incorporates our particle scanner Rapid Nano 4 for front side inspection of reticle blanks with a detection limit down to 20 nm particles. Attached to the handler is also an Optical Coherence Tomography (OCT) inspection tool for back-side reticle or pellicle inspection with a resolution down to 1 micron.

  18. Influence of cataract surgery on optical coherence tomography and neurophysiology measurements in patients with retinitis pigmentosa.

    Science.gov (United States)

    Garcia-Martin, Elena; Rodriguez-Mena, Diego; Dolz, Isabel; Almarcegui, Carmen; Gil-Arribas, Laura; Bambo, Maria P; Larrosa, Jose M; Polo, Vicente; Pablo, Luis E

    2013-08-01

    To evaluate the effect of uncomplicated cataract phacoemulsification on the measurements of visual evoked potentials (VEP), pattern electroretinogram (PERG), and macular and retinal nerve fiber layer (RNFL) using 2 spectral-domain optical coherence tomography (OCT) instruments, the Cirrus OCT (Carl Zeiss Meditech) and Spectralis OCT (Heidelberg Engineering), in patients with retinitis pigmentosa (RP), and to assess the reliability of the OCT measurements before and after cataract surgery. Observational cross-sectional study. Thirty-five eyes of 35 patients with RP (20 men and 15 women, 45-66 years) who underwent cataract phacoemulsification were studied. At 1 month before and 1 month after surgery, visual acuity, VEP, PERG, and 3 repetitions of scans using the RNFL and macular analysis protocols of the Cirrus and Spectralis OCT instruments were performed. The differences in measurements between the 2 visits were analyzed. Repeatability of OCT measurements was evaluated by calculating the coefficients of variation. VEP amplitude, RNFL thicknesses provided by Cirrus and Spectralis, and macular measurements provided by Cirrus OCT differed between the 2 visits. VEP latency, PERG measurements, and macular thicknesses provided by the Spectralis OCT before surgery did not differ significantly from those after surgery. The OCT repeatability was better after surgery, with lower coefficients of variation for scans performed after surgical removal of the cataract. The nuclear, cortical, and posterior subcapsular types of cataracts did not show different repeatability. The presence of cataracts affects VEP amplitude, RNFL, and macular measurements performed with OCT in eyes with RP. Image repeatability significantly improves after cataract phacoemulsification. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Advanced fire observation by the Intelligent Infrared Sensor prototype FOCUS on the International Space Station

    Science.gov (United States)

    Oertel, D.; Haschberger, P.; Tank, V.; Lanzl, F.; Zhukov, B.; Jahn, H.; Briess, K.; Lorenz, E.; Roeser, H.-P.; Ginati, A.; Tobehn, C.; Schulte in den Bäumen, J.; Christmann, U.

    1999-01-01

    Current and planned operational space-borne Earth observation systems provide spatially, radiometrically or temporally crude data for the detection and monitoring of high temperature phenomena on the surface of our planet. High Temperature Events (HTE) very often cause environmental disasters. Such HTE are forest and savannah fires, fires of open coal mines, volcanic activities and others (e.g. fires of oil wells, pipelines etc.). A simultaneous co-registration of a combination of infrared (IR) and visible (VIS) channels is the key for a reliable autonomous on-board detection of High Temperature Events (HTE) on Earth surface, such as vegetation fires and volcano eruptions. This is the main feature of the FOCUS experiment. Furthermore there are ecology-oriented objectives of the FOCUS experiment mainly related to spectrometric/imaging remote inspection and parameter extraction of selected HTEs, and to the assessment of some ecological consequences of HTEs, such as aerosol and gas emission. Based on own experimental work and supported by Co-Investigators from Italy, Greece, France, Spain, Russia and Germany, DLR proposed in 1997 to use the International Space Station (ISS) in its early utilization phase as a platform and test-bed for an Intelligent Infrared Sensor prototype FOCUS of a future Environmental Disaster Recognition Satellite System. FOCUS is considered by ESA as an important mission combining a number of proven technologies and observation techniques to provide the scientific and operational user community with key data for the classification and monitoring of forest fires. FOCUS was selected as one of five European ``Groupings'' to be flown as an externally mounted payload during the early utilisation phase of the ISS. The FOCUS Phase A Study will be performed by OHB-System, DLR and Zeiss from September 1998 until May 1999.

  20. Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Leisser, Christoph; Hackl, Christoph; Hirnschall, Nino; Luft, Nikolaus; Döller, Birgit; Draschl, Petra; Rigal, Karl; Findl, Oliver

    2016-04-01

    The aim of this study was to examine the quality of intraoperative visualization of the posterior hyaloid, epiretinal membrane (ERM), inner limiting membrane (ILM), and hyporeflective subfoveal zone with a commercially available, microscope-integrated spectral-domain OCT setup (mi-SD-OCT) (Rescan 700; Carl Zeiss Meditec AG, Germany). Twenty patients prospectively scheduled for pars plana vitrectomy with membrane peeling due to an idiopathic ERM were included. Standard 23-gauge, three-port pars plana vitrectomy with membrane peeling and staining of the ERM with a trypan blue-based chromovitrectomy dye was performed in all cases. Intraoperative SD-OCT was performed before and after peeling and visualization of the posterior hyaloid, ERM, ILM, and presence of subfoveal hyporeflective zones were examined. OCT follow-ups were performed 2 days and 3 months after surgery. The study was approved by the local ethics committee of the city of Vienna. Successful intraoperative visualization of ERM by mi-SD-OCT was possible in all cases. The posterior hyaloid and ILM could not be seen in the mi-SD-OCT scans, whereas an intraoperative subfoveal hyporeflective zone presented in 35% of cases. In 12.5% an independent subfoveal hyporeflective zone presented postoperatively. Visual acuity improved in 93.8% of patients after surgery. mi-SD-OCT appears to be a valuable tool for intraoperative visualization of the ERM and offers immediate visualization of retinal anatomy during peeling. Therefore, it adds to the understanding of intraoperative traumatic changes due to the peeling procedure. Copyright 2016, SLACK Incorporated.

  1. Study and optimisation of SIMS performed with He+ and Ne+ bombardment

    International Nuclear Information System (INIS)

    Pillatsch, L.; Vanhove, N.; Dowsett, D.; Sijbrandij, S.; Notte, J.; Wirtz, T.

    2013-01-01

    The combination of the high-brightness He + /Ne + atomic level ion source with the detection capabilities of secondary ion mass spectrometry (SIMS) opens up the prospect of obtaining chemical information with high lateral resolution and high sensitivity on the Zeiss ORION helium ion microscope (HIM). A feasibility study with He + and Ne + ion bombardment is presented in order to determine the performance of SIMS analyses using the HIM. Therefore, the sputtering yields, useful yields and detection limits obtained for metallic (Al, Ni and W) as well as semiconductor samples (Si, Ge, GaAs and InP) were investigated. All the experiments were performed on a Cameca IMS4f SIMS instrument which was equipped with a caesium evaporator and oxygen flooding system. For most of the elements, useful yields in the range of 10 −4 to 3 × 10 −2 were measured with either O 2 or Cs flooding. SIMS experiments performed directly on the ORION with a prototype secondary ion extraction and detection system lead to results that are consistent with those obtained on the IMS4f. Taking into account the obtained useful yields and the analytical conditions, such as the ion current and typical dwell time on the ORION HIM, detection limits in the at% range and better can be obtained during SIMS imaging at 10 nm lateral resolution with Ne + bombardment and down to the ppm level when a lateral resolution of 100 nm is chosen. Performing SIMS on the HIM with a good detection limit while maintaining an excellent lateral resolution (<50 nm) is therefore very promising.

  2. The neon gas field ion source-a first characterization of neon nanomachining properties

    International Nuclear Information System (INIS)

    Livengood, Richard H.; Tan, Shida; Hallstein, Roy; Notte, John; McVey, Shawn; Faridur Rahman, F.H.M.

    2011-01-01

    At the Charged Particle Optics Conference (CPO7) in 2006, a novel trimer based helium gas field ion source (GFIS) was introduced for use in a new helium ion microscope (HIM), demonstrating the novel source performance attributes and unique imaging applications of the HIM (Hill et al., 2008 ; Livengood et al., 2008 ). Since that time there have been numerous enhancements to the HIM source and platform demonstrating resolution scaling into the sub 0.5 nm regime (Scipioni et al., 2009 ; Pickard et al., 2010 ). At this Charged Particle Optics Conference (CPO8) we will be introducing a neon version of the trimer-GFIS co-developed by Carl Zeiss SMT and Intel Corporation. The neon source was developed as a possible supplement to the gallium liquid metal ion source (LMIS) used today in most focused ion beam (FIB) systems (Abramo et al., 1994 ; Young et al.,1998 ). The neon GFIS source has low energy spread (∼1 eV) and a small virtual source size (sub-nanometer), similar to that of the helium GFIS. However neon does differ from the helium GFIS in two significant ways: neon ions have high sputtering yields (e.g. 1 Si atom per incident ion at 20 keV); and have relatively shallow implant depth (e.g. 46 nm in silicon at 20 keV). Both of these are limiting factors for helium in many nanomachining applications. In this paper we will present both simulation and experimental results of the neon GFIS used for imaging and nanomachining applications.

  3. The deformation of wax patterns and castings in investment casting technology

    Directory of Open Access Journals (Sweden)

    A. Herman

    2012-01-01

    Full Text Available The dimensional accuracy of the final casting of Inconel alloy 738 LC is affected by many aspects. One of them is the choice of method and time of cooling wax model for precision investment casting. The main objective was to study the initial deformation of the complex shape of the casting of the rotor blades. Various approaches have been tested for cooling wax pattern. When wax models are cooling on the air, without clamping in jig for cooling, deviations from the ideal shape of the casting are very noticeable (up to 8 mm and most are in extreme positions of the model. When blade is cooled in fixing jig in water environment, the resulting deviations compared with cooling in air are significantly larger, sometimes up to 10 mm. This itself does not mean that the final shape of the casting is dimensionally more accurate with usage of wax models, which have deviations from the ideal position smaller. Another deformation occurs when shell mould is produced around wax pattern and furthermore deformations emerge while casting of blade is cooling. This paper demonstrates first steps in describing complex process of deformations of Inconel alloy blades produced with investment casting technology by comparing results from thermal imagery, simulations in foundry simulation software ProCAST 2010 and measurements from CNC scanning system Carl Zeiss MC 850. Conclusions are so far not groundbreaking, but it seems deformations of wax pattern and deformations of castings do in some cases cancel each other by having opposite directions. Describing entirely whole process of deformations will help increase precision of blade castings so that models at the beginning and blades in the end are the same.

  4. Factors affecting reading speed in patients with diabetic macular edema treated with laser photocoagulation.

    Directory of Open Access Journals (Sweden)

    Elizabeth Pearce

    Full Text Available PURPOSE: To study the factors that may affect reading speed in patients with diabetic macular edema previously treated with laser photocoagulation. METHODS: Consecutive patients with type II diabetes treated with laser photocoagulation for diabetic macular edema (DME at least twelve months previously, with best corrected visual acuity of better than 65 letters (approximately 20/40 measured with Early Treatment Diabetic Retinopathy Study (ETDRS charts were included in this study. Patients previously treated with pan-retinal photocoagulation, vitrectomy, intravitreal steroid or anti-VEGF therapy were excluded. Any other ocular co-morbidities that may influence reading ability such as cataract, glaucoma or macular degeneration were also excluded. All patients were refracted by a certified examiner, the following measurements were collected: best corrected visual acuity (BCVA, contrast sensitivity with Pelli-Robson chart, reading speed with MNREAD chart, microperimetry with Nidek MP1, and central subfield thickness with Zeiss spectral domain optical coherent topography. RESULTS: The slow reading group had poorer contrast sensitivity (p = 0.001, reduced retinal sensitivity (p = 0.027 and less stable fixation (p = 0.013. Most interestingly the reduced retinal sensitivity findings were driven by the microperimetry value on the right subfield (p = 0.033, (nasal to the fovea in the right eye and temporal to the fovea in the left eye. Multiple linear regression analysis showed that contrast sensitivity is probably the most important factor that affects reading speed (p = 0.001. CONCLUSION: Reduced retinal sensitivity after laser treatment is associated with reduced reading speed in patients with diabetic macular edema.

  5. A New Sensor for Surface Process Quantification in the Geosciences - Image-Assisted Tacheometers

    Science.gov (United States)

    Vicovac, Tanja; Reiterer, Alexander; Rieke-Zapp, Dirk

    2010-05-01

    -millimeter to millimeter measurements of the same area in the field is demanding. To measure for example current day erosion rates point probing techniques require a rock anchor as reference point disturbing the vicinity of the sampling area and such measurements are only valid for a very limited part of the object. A precise method for quantification of areas larger than 1 m² with sub-millimeter accuracy is "badly needed", but not available off the shelf. The method should be non-contacting as well as non-disturbing and suitable for field use even in remote areas. Image assisted measurement techniques combine the pointing precision of a theodolite with the ability of mass point measurement from stereo imagery. A high-precision contactless detection of chances of surfaces is possible. In comparison with laser scanners, image-assisted tacheometer measure objects with higher accuracy; compared to photogrammetric systems, they can be easier used for on-line measurement processes (e.g. object monitoring) - this will especially be the case if the measurements can be performed with a high degree of automation. Acknowledgments: The presented research has been supported by the Austrian Science Foundation (FWF) Project i-MeaS and by the European Sciences Foundation (ESF) project SedyMONT.

  6. Prototype study of characterization of the impact that produces the diffuser of an industrial discharge into the sea water; Estudio prototipo de caracterizacion del impacto que produce el difusor de una descarga industrial sobre el medio marino

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz Gallarza, S. M.; Gil Zurita, A.; Garcia Hernandez, R.; Vergara Mendez, S.; Garcia Leal, M. L. [Universidad Autonoma Metropolitana, Mexico, D.F. (Mexico)

    2000-09-01

    To establish maximum permissible limits of pollutants discharged into the sea from industrial wastewater, the authorities involved in the environmental protection and regulation had established particular characteristic for their discharges in each enterprise. In addition to taking care of the conservation of those limits, the effect of these substances on the environment needs to be evaluated. Along this line, integral multidisciplinary studies of impact characterization on the marine environment induced by the industry have been carried out. One of the industrial enterprises that discharges into the northwestern coastline of the Gulf of Mexico through a submarine diffuser, requested the execution of the first study of this kind. This prototype study included physical, chemical, biological and geological determinations in a network of 49 sampling sites along six transects positioned from a boat, and with theodolites from the coast; covering five depth levels (surface, 4, 8, 12 and 16 m) during rainy, dry and northern winds seasons. Heavy metals in the water, sediments, and organisms and in combined samples of the industrial discharge were determined. Continuous measurements of marine currents, salinity and temperature in the nozzles of the diffuser were performed by means of two S4 Inter Ocean current meters. Helicopters flights were made to observe the displacement variations of the pollutants plume under various climatic conditions. LANDSAT TM satellite images were acquired to obtain information on diverse regions of the electromagnetic spectrum and to verify observations on the behavior of the discharge plume. Besides the conventional methods of plotting and information processing, tri-dimensional visualization was applied with the purpose of interpreting seasonal and diffusion patterns. Because of the excellent results obtained with this methodology, this study is made available to specialists as a prototype for determining the coastal marine environmental

  7. Frost heaving of planted tree seedlings in the boreal forest of northern Sweden

    International Nuclear Information System (INIS)

    Goulet, France

    2000-01-01

    maximum frost heaving of the seedlings. In the third field experiment snow cover also showed to be an important factor in regard to frost heaving of tree seedlings. In a snow-free treatment combined with soil scarification, an uplift of 14.6 cm was measured during a winter season. In contrast no vertical displacement was observed under a simulated snow cover. The strong influence of snow on the extent of frost heaving indicates that further investigation should be focused on the interaction between maximum frost heaving and snow depth. In the laboratory freezing chamber experiment it was demonstrated that soil from spodic B horizon is less susceptible to frost heaving than soil from E horizon. Needle ice did not grow at all on soil samples from E horizon during a 3-day test, neither on fresh, nor on oven dried samples. On fresh samples of soil from Bs horizon, needle ices reached a maximum height of 9.7 cm in average. The use of theodolite and wooden dowels to estimate the extent of frost heaving in this study allowed to follow the process during the frost heaving period. A vertical uplift in millimetres could be recorded. A development of reliable measuring methods which allow a continuous estimation of the extent of frost heaving damage during the whole process, would undoubtedly represent an important step towards a better understanding of frost heaving of tree seedlings

  8. Solar energy potential atlas for planning energy system off-grid electrification in the Republic of Djibouti

    International Nuclear Information System (INIS)

    Pillot, Benjamin; Muselli, Marc; Poggi, Philippe; Haurant, Pierrick; Hared, Idriss

    2013-01-01

    accuracy of this solar atlas, we then disaggregated irradiation maps with a 3 arcsec (∼90 m at the equator) Digital Elevation Model (DEM), by taking into consideration terrain-related shading effects and elevation gradient. As current software solutions do not allow downscaling of preprocessed maps, we performed this work by computing our own global model, combination of horizon, elevation correction and irradiance splitting models. The horizon model we developed was assessed and compared with other existing models by using a theodolite in mountainous areas of Corsica. Finally, according to the final computed atlas, during the year 2010, mean irradiation all over the country was around 2100 kW h/m 2 and about 82% of the country received over 2000 kW h/m 2 . Furthermore, the solar radiation reaching Djibouti corresponded to 20,000 times the total yearly energy consumption of the country in 2005. The retrieved irradiation maps can be used to evaluate relevance of the solar resource over rural areas of the country, and implemented within energy models in order to size stand-alone solar systems

  9. Frost heaving of planted tree seedlings in the boreal forest of northern Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Goulet, France

    2000-07-01

    maximum frost heaving of the seedlings. In the third field experiment snow cover also showed to be an important factor in regard to frost heaving of tree seedlings. In a snow-free treatment combined with soil scarification, an uplift of 14.6 cm was measured during a winter season. In contrast no vertical displacement was observed under a simulated snow cover. The strong influence of snow on the extent of frost heaving indicates that further investigation should be focused on the interaction between maximum frost heaving and snow depth. In the laboratory freezing chamber experiment it was demonstrated that soil from spodic B horizon is less susceptible to frost heaving than soil from E horizon. Needle ice did not grow at all on soil samples from E horizon during a 3-day test, neither on fresh, nor on oven dried samples. On fresh samples of soil from Bs horizon, needle ices reached a maximum height of 9.7 cm in average. The use of theodolite and wooden dowels to estimate the extent of frost heaving in this study allowed to follow the process during the frost heaving period. A vertical uplift in millimetres could be recorded. A development of reliable measuring methods which allow a continuous estimation of the extent of frost heaving damage during the whole process, would undoubtedly represent an important step towards a better understanding of frost heaving of tree seedlings.

  10. Análise cinemática tridimensional do movimento de eqüinos em esteira rolante Three-dimensional cinematic analysis of the horse movement in treadmill

    Directory of Open Access Journals (Sweden)

    F.G. Christovão

    2007-08-01

    Full Text Available Adaptou-se uma metodologia utilizada no estudo do movimento humano para analisar o movimento de eqüinos em esteira rolante de alto desempenho, construindo-se um sistema de calibração utilizando-se um teodolito eletrônico de alta precisão e calibradores que demarcavam o espaço ocupado pelo animal. Dessa forma, foram obtidas as coordenadas espaciais dos marcadores presentes nos calibradores, compondo o arquivo de calibração. Duas câmeras de vídeo (60Hz foram posicionadas em vista lateral esquerda, distantes 5m da manta de rolagem da esteira a 1,8m de altura. As imagens foram enquadradas utilizando-se um monitor de vídeo. Para a validação do método, um membro da equipe movimentou, no espaço calibrado, uma haste rígida com marcadores fixados nas suas extremidades, distantes um do outro 43,8cm. Para a análise das imagens, utilizou-se o programa Dvideow, desenvolvido pelo Laboratório de Instrumentação para Biomecânica - UNICAMP. Após a reconstrução tridimensional das imagens utilizou-se um programa matemático para o cálculo do valor médio da distância entre os marcadores. Obteve-se, após a mensuração em 100 quadros, o valor médio de 43,7cm com coeficiente de variação de 0,8%. Estes resultados mostram que a metodologia desenvolvida é precisa e adequada para o estudo da locomoção de eqüinos.A methodology used for the study of human movement was adapted to analyze the movement of equines in a high performance treadmill. An electronic high precision theodolite was used to construct a calibration system to demarcate the volume occupied by the animal. It was taken the three dimensions coordinates of each marker present in the calibrator, composing the calibration archive. Two video cameras (60 Hz were located approximately 5m from the left lateral side of the treadmill at 1.8m height. The images had been fit using a video monitor. For the validation of the method, a member of the team moved into the calibrated space, a

  11. Hydrological regime as key to the morpho-texture and activity of braided streams

    Science.gov (United States)

    Storz-Peretz, Y.; Laronne, J. B.

    2012-04-01

    Braided streams are a common fluvial pattern in different climates. However, studies of gravel braided streams have mainly been conducted in humid braided systems or in flume simulations thereof, leaving arid braided streams scarcely investigated. Dryland rivers have bare catchments, rapid flow recession and unarmoured channel beds which are responsible for very high bedload discharges, thereby increasing the likelihood for braiding. Our main objective is to characterize the morpho-texture of the main morphological elements - mid-channel bars, chutes and anabranches (braid-cells) in the dryland braided system and compare them to their humid counterparts. Selected areas of the dryland braided Wadis Ze'elim, Rahaf and Roded in the SE hyper-arid Israel were measured, as were La-Bleone river in the French pre-alps along with the Saisera and Cimoliana rivers in NE Italy representing humid braided systems. Terrestrial Laser Scanning (TLS) of morphological units produced point clouds from which high resolution accurate Digital Elevation Models (DEMs) were extracted. Active braid cells in humid environments were also surveyed by electronic theodolite. Roughness and upper tail Grain Size Distribution (GSD) quantiles were derived from the scanned point clouds or from Wolman sampling. Results indicate that dryland anabranches tend to be finer-grained and less armoured than the bars, contrary to the humid braided systems, where the main or larger anabranches are coarser-grained and more armoured than the bars. Chutes are commonly similar or coarser-grained than the bars they dissect, in accordance with their steeper gradients due to the considerable relief of the bar-anabranch. The morpho-texture displayed in the steep braided Saisera River, located in the Italian Dolomites having the highest annual precipitation, has similarity to that of the dryland braided channels. In drylands coarse gravel is deposited mainly as bars due to the high flux of bedload, whereas the rapid flow

  12. Optical coherence tomography, scanning laser polarimetry and confocal scanning laser ophthalmoscopy in retinal nerve fiber layer measurements of glaucoma patients.

    Science.gov (United States)

    Fanihagh, Farsad; Kremmer, Stephan; Anastassiou, Gerasimos; Schallenberg, Maurice

    2015-01-01

    To determine the correlations and strength of association between different imaging systems in analyzing the retinal nerve fiber layer (RNFL) of glaucoma patients: optical coherence tomography (OCT), scanning laser polarimetry (SLP) and confocal scanning laser ophthalmoscopy (CSLO). 114 eyes of patients with moderate open angle glaucoma underwent spectral domain OCT (Topcon SD-OCT 2000 and Zeiss Cirrus HD-OCT), SLP (GDx VCC and GDx Pro) and CSLO (Heidelberg Retina Tomograph, HRT 3). Correlation coefficients were calculated between the structural parameters yielded by these examinations. The quantitative relationship between the measured RNFL thickness globally and for the four regions (superior, inferior, nasal, temporal) were evaluated with different regression models for all used imaging systems. The strongest correlation of RNFL measurements was found between devices using the same technology like GDx VCC and GDx Pro as well as Topcon OCT and Cirrus OCT. In glaucoma patients, the strongest associations (R²) were found between RNFL measurements of the two optical coherence tomography devices Topcon OCT and Cirrus OCT (R² = 0.513) and between GDx VCC and GDx Pro (R² = 0.451). The results of the OCTs and GDX Pro also had a strong quantitative relationship (Topcon OCT R² = 0.339 and Cirrus OCT R² = 0.347). GDx VCC and the OCTs showed a mild to moderate association (Topcon OCT R² = 0.207 and Cirrus OCT R² = 0.258). The confocal scanning laser ophthalmoscopy (HRT 3) had the lowest association to all other devices (Topcon OCT R² = 0.254, Cirrus OCT R² = 0.158, GDx Pro R² = 0.086 and GDx VCC R² = 0.1). The measurements of the RNFL in glaucoma patients reveal a high correlation of OCT and GDx devices because OCTs can measure all major retinal layers and SLP can detect nerve fibers allowing a comparison between the results of this devices. However, CSLO by means of HRT topography can only measure height values of the retinal surface but it cannot distinguish

  13. Evaluation of Partial Breast Reirradiation with Intraoperative Radiotherapy after Prior Thoracic Radiation: A Single-Institution Report of Outcomes and Toxicity

    Directory of Open Access Journals (Sweden)

    Christine Chin

    2017-08-01

    Full Text Available IntroductionMastectomy is the current standard of care for ipsilateral breast tumor recurrences after prior whole breast irradiation (WBI. We report our single-institution experience with breast-conserving surgery (BCS followed by intraoperative radiotherapy (IORT as an alternative to salvage mastectomy for new or recurrent breast cancers that develop in the setting of prior thoracic radiation.MethodsWe performed an IRB-approved retrospective review of patients treated with breast IORT between September 2013 and November 2016. We identified 12 patients who declined salvage mastectomy for their breast cancer after prior thoracic radiation. IORT was delivered using the Intrabeam™ device (Carl Zeiss, Germany. A dose of 20 Gy was prescribed to the lumpectomy cavity surface using 50 kV X-rays. We graded both acute and late treatment-related breast toxicities using the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Local control, mastectomy-free survival, distant metastasis, and overall survival were determined.ResultsOur study included nine patients who developed a new or recurrent ipsilateral breast cancer after prior WBI for early-stage breast cancer, two patients with primary breast cancer after mantle-field radiation for Hodgkin’s lymphoma, and one patient with a synchronous stage III non-small cell lung cancer treated with definitive radiation to the ipsilateral lung and mediastinum. The median time from prior radiation to presentation was 18 years (range: 2 months to 46 years. All patients successfully underwent partial breast reirradiation with IORT and were able to preserve their breast. At a median follow-up of 14 months (4–25 months, there were no local or distant recurrences. There was a single non-cancer-related death. In the acute setting, we observed grade 1 toxicity in 58% (n = 7, grade 2 toxicity in 17% (n = 2, and no grade 3 or higher toxicity. In the late setting, at

  14. Feasibility of simultaneous sodium fluorescein and indocyanine green injection in neurosurgical procedures.

    Science.gov (United States)

    Acerbi, F; Restelli, F; Broggi, M; Schiariti, M; Ferroli, P

    2016-07-01

    The objective of this study is to assess the feasibility of simultaneous Sodium Fluorescein (SF) and Indocyanine Green (ICG) injection during neurosurgical procedures. Three patients harboring a high-grade glioma (HGG) were retrospectively identified in the surgical database of the Neurosurgical Unit 2 at the Foundation IRCCS Istituto Neurologico C. Besta in Milan, by having received intraoperatively both SF for tumor resection and ICG for vasculature angiographic studies in the same surgical procedure. We identified 2 males and 1 female (age range 25-60). Lesions were located in the left temporo-polar area and hippocampus (1 case), right superior frontal gyrus (1 case), left supplementary motor area (1 case). All the three lesions showed Magnetic Resonance Imaging (MRI) characteristics of HGG and, for this reason, in all patients a fluorescein-guided tumor removal was proposed. In the same surgical procedure ICG videoangiography was considered necessary in order to study arterial and venous vasculature, given by the strict relation of the tumor with an unexpected Posterior Communicating Artery (PComA) aneurysm in one case and with cortical drainage veins complexes in the other two cases. In all cases a microscope equipped with both YELLOW560 and IR800 integrated filters (Pentero 900, Carl Zeiss, Oberkorchen, Germany) was used. Fluorescein was i.v. injected at a dose of 5mg/kg immediately after patient intubation. ICG was i.v. injected in bolus on demand of the operating surgeon at a dose of 12.5mg. No side-effects related to simultaneous injection of SF and ICG were identified. In all three cases, the use of SF allowed to better visualize the tumor areas during surgical removal, thus leading to a radical resection until no macroscopic appearance of residual tumor mass and no fluorescence was visible in the surgical cavity. ICG videoangiography confirmed the patency of branches of internal carotid artery after clipping of an unexpected small PComA aneurysm found

  15. Significant Axial Elongation with Minimal Change in Refraction in 3- to 6-Year-Old Chinese Preschoolers: The Shenzhen Kindergarten Eye Study.

    Science.gov (United States)

    Guo, Xinxing; Fu, Min; Ding, Xiaohu; Morgan, Ian G; Zeng, Yangfa; He, Mingguang

    2017-12-01

    To document the distribution of ocular biometry and to evaluate its associations with refraction in a group of Chinese preschoolers. Population-based cross-sectional study. A total of 1133 preschoolers 3 to 6 years of age from 8 representative kindergartens. Biometric measurements including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR) were obtained from partial-coherence laser interferometry (IOL Master; Carl Zeiss Meditec, Oberkochen, Germany) before cycloplegia. Lens power (LP) and AL-to-CR ratio were calculated. Cycloplegic refraction (3 drops of 1% cyclopentolate) was measured using an autorefractor (KR8800; Topcon Corp., Tokyo, Japan), and spherical equivalent refraction (SER) was calculated. Biometric and refractive parameters were assessed as a function of age and gender. Multiple regression analysis was performed to explore the associations between refraction and ocular biometry. Ocular biometric distributions and their relationships to refraction. Among the 1127 children (99.5%) with successful cycloplegic refraction, mean SER was 1.37±0.63 diopters (D). Prevalence of myopia increased from 0% at 3 years of age to 3.7% (95% confidence interval, 1.0%-6.5%) at 6 years of age. Biometric parameters followed Gaussian distributions with means of 22.39±0.68 mm for AL, 7.79±0.25 mm for CR, and 24.61±1.42 D for calculated LP; and non-Gaussian distributions with means of 3.34±0.24 mm for ACD and 2.88±0.06 for AL-to-CR ratio. Axial length, ACD, and AL-to-CR ratio increased from 3 to 6 years of age, CR remained stable, whereas LP declined. Overall, SER declined slightly. For the SER variance, AL explained 18.6% and AL-to-CR ratio explained 39.8%, whereas AL, CR, and LP accounted for 80.0% after adjusting for age and gender. Young Chinese children are predominantly mildly hyperopic, with a low prevalence of myopia by the age of 6 years. An increase of 1 mm in AL was associated with only 0.45 D of myopic change. Decreases in

  16. DENDROCHRONOLOGY of ABIES NORDMANNIANA (STEV. SPACH. SUBSP. NORDMANNIANA IN THE ÖRÜMCEK FORESTS IN KÜRTÜN-GÜMÜSHANE

    Directory of Open Access Journals (Sweden)

    Zafer Cemal Özkan

    2003-04-01

    Full Text Available Abies nordmanniana (Stev. Spach. subsp. nordmanniana Dogu Karadeniz Bölgesi için olduğu kadar Türkiye için de önemli bir orman ağacıdır. Çalışmanın amacı; Doğu Karadeniz Göknarı ağaçlarının yıllık büyüme ve değişimleri araştırıp, incelemek ve yıllık halkalardan yararlanarak Örümcek Bölgesi Ormanlarında göknar için ortalama yıllık halka eğrisi ve standart kronoloji hazırlamaktır. Aynı zamanda yörenin eteorolojik verileri de kullanılarak geçmiş yılların iklimi hakkında bilgi edinebilmek amacıyla yapılacak olan dendroklimatoloji çalışmalarına esas oluşturacaktır. Araştırma alanı Karadeniz Bölgesinin, Doğu Karadeniz Bölümünde yer almakta, Gümüşhane ili, Kürtün ilçesi sınırları içerisinde kalmaktadır. Toplam 6 ağaçtan 12 kalem alınmıştır ve elde edilen kalemlerdeki yıllık halka genişliklerinin ölçümünde 0.01 mm. duyarlı Zeiss Winkel aleti kullanılmıştır. Yıllık halka eğrilerinin elde edilmesinde ; 1 Yıllık Halkaların Yarı Logaritmik Olarak Gösterilmesi, 2 Yıllık Halkalardan Elde Edilen İndislerin Bir Grafikle Gösterilmesi (Standardizasyon yöntemleri kullanılmıştır. İndis değerlerinin bulunmasında ise It=Wt/Yt eşitliğinden yararlanılmıştır. Çalışma 1729 –2003 yıllarını kapsamaktadır.

  17. TU-AB-BRC-07: Efficiency of An IAEA Phase-Space Source for a Low Energy X-Ray Tube Using Egs++

    Energy Technology Data Exchange (ETDEWEB)

    Watson, PGF; Renaud, MA; Seuntjens, J [McGill University, Montreal, Quebec (Canada)

    2016-06-15

    Purpose: To extend the capability of the EGSnrc C++ class library (egs++) to write and read IAEA phase-space files as a particle source, and to assess the relative efficiency gain in dose calculation using an IAEA phase-space source for modelling a miniature low energy x-ray source. Methods: We created a new ausgab object to score particles exiting a user-defined geometry and write them to an IAEA phase-space file. A new particle source was created to read from IAEA phase-space data. With these tools, a phase-space file was generated for particles exiting a miniature 50 kVp x-ray tube (The INTRABEAM System, Carl Zeiss). The phase-space source was validated by comparing calculated PDDs with a full electron source simulation of the INTRABEAM. The dose calculation efficiency gain of the phase-space source was determined relative to the full simulation. The efficiency gain as a function of i) depth in water, and ii) job parallelization was investigated. Results: The phase-space and electron source PDDs were found to agree to 0.5% RMS, comparable to statistical uncertainties. The use of a phase-space source for the INTRABEAM led to a relative efficiency gain of greater than 20 over the full electron source simulation, with an increase of up to a factor of 196. The efficiency gain was found to decrease with depth in water, due to the influence of scattering. Job parallelization (across 2 to 256 cores) was not found to have any detrimental effect on efficiency gain. Conclusion: A set of tools has been developed for writing and reading IAEA phase-space files, which can be used with any egs++ user code. For simulation of a low energy x-ray tube, the use of a phase-space source was found to increase the relative dose calculation efficiency by factor of up to 196. The authors acknowledge partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant No. 432290).

  18. Incidence and Outcomes of Optical Zone Enlargement and Recentration After Previous Myopic LASIK by Topography-Guided Custom Ablation.

    Science.gov (United States)

    Reinstein, Dan Z; Archer, Timothy J; Carp, Glenn I; Stuart, Alastair J; Rowe, Elizabeth L; Nesbit, Andrew; Moore, Tara

    2018-02-01

    To report the incidence, visual and refractive outcomes, optical zone enlargement, and recentration using topography-guided CRS-Master TOSCA II software with the MEL 80 excimer laser (Carl Zeiss Meditec AG, Jena, Germany) after primary myopic laser refractive surgery. Retrospective analysis of 73 eyes (40 patients) with complaints of night vision disturbances due to either a decentration or small optical zone following a primary myopic laser refractive surgery procedure using the MEL 80 laser. Multiple ATLAS topography scans were imported into the CRS-Master software for topography-guided ablation planning. The topography-guided re-treatment procedure was performed as either a LASIK flap lift, a new LASIK flap, a side cut only, or photorefractive keratectomy. Axial curvature maps were analyzed using a fixed grid and set of concentric circles superimposed to measure the topographic optical zone diameter and centration. Follow-up was 12 months. The incidence of use in the population of myopic treatments during the study period was 0.79% (73 of 9,249). The optical zone diameter was increased by 11% from a mean of 5.65 to 6.32 mm, with a maximum change of 2 mm in one case. Topographic decentration was reduced by 64% from a mean of 0.58 to 0.21 mm. There was a 44% reduction in spherical aberration, 53% reduction in coma, and 39% reduction in total higher order aberrations. A subjective improvement in night vision symptoms was reported by 93%. Regarding efficacy, 82% of eyes reached 20/20 and 100% reached 20/32 (preoperative CDVA was 20/20 or better in 90%). Regarding safety, no eyes lost two lines of CDVA and 27% gained one line. Regarding predictability, 71% of re-treatments were within ±0.50 diopters. Topography-guided ablation was effective in enlarging the optical zone, recentering the optical zone, and reducing higher order aberrations. Topography-guided custom ablation appears to be an effective method for re-treatment procedures of symptomatic patients after

  19. The architecture of Hamburg-Bergedorf Observatory 1906 - 1912, compared with other observatories (German Title: Die Architektur der Hamburg-Bergedorfer Sternwarte 1906 - 1912 im Vergleich mit anderen Observatorien)

    Science.gov (United States)

    Müller, Peter

    The foundation of the astrophysical observatories in Potsdam-Telegrafenberg in 1874, in Meudon near Paris in 1875 and in Mount Hamilton in California in 1875 resulted in a complete change of observatory architecture. Astrometry had become irrelevant; meridian halls, i.e. an exact north-south orientation, were no longer necessary. The location in the centre of a (university) town was disadvantageous, due to vibrations caused by traffic and artificial light at night. New principles were defined: considerable distance (from the city center), secluded and exposed position (on a mountain) and construction of pavilions: inside a park a pavilion was built for each instrument. Other observatories of this type are: Pic du Midi in the French Alps, built as from 1878 as the first permanent observatory in the high mountains; Nice, Mont Gros, (1879); Brussels, Uccle (1883); Edinburgh, Blackford Hill (1892); Heidelberg, Königstuhl (1896); Barcelona, Monte Tibidado (1902). The original Hamburg Observatory was a modest rectangular building near the Millernrtor; in 1833 it became a State institute. As from 1906 erection of a spacious complex in Bergedorf, 20 km northeast of the city center, took place. Except for the unavailable position on a mountain, this complex fulfilled all principles of a modern observatory: in a park pavilion architecture in an elegant neo-baroque style designed by Albert Erbe (architect of the new Hamburger Kunsthalle with cupola). At the Hamburg Observatory the domed structures were cleverly hierarchised leaving an open view to the south. At the beginning astrometry and astrophysics were equally important; there was still a meridian circle. Apart from that, the instruments were manifold: a large refractor 0.60 m (installed by Repsold/Hamburg, 9 m focal length) and a large reflector 1 m (Zeiss/Jena, 3m focal length). Both were the largest instruments of their kind in the German Empire. In addition, there was the Lippert Astrograph on an elegant polar

  20. Four-year to seven-year outcomes of advanced surface ablation with excimer laser for high myopia.

    Science.gov (United States)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob; Grønbech, Keea Treu; Vestergaard, Anders Højslet

    2015-07-01

    We aimed to evaluate and compare outcomes after photorefractive keratectomy with cooling (cPRK) and laser-assisted subepithelial keratectomy (LASEK) for high myopia. This was a retrospective, single-masked follow-up study of patients treated for myopia between 2007 and 2009 with cPRK or LASEK, using a high-frequency flying-spot excimer laser with eye-tracker (MEL80; Carl Zeiss, Jena, Germany). One eye of each patient was randomly chosen for analysis. Re-treated eyes were excluded. Forty-six cPRK patients and 35 LASEK patients were included. Spherical equivalent averaged -7.69 ± 1.47 diopters (D) in cPRK eyes and -7.98 ± 2.06 D in LASEK eyes (p = 0.31) before surgery. The average follow-up time was 4.6 years in cPRK patients and 6.0 years in LASEK patients (p < 0.05). At final follow-up, no cPRK eyes and one LASEK eye (p = 0.46) had lost two lines of corrected distance visual acuity (CDVA). No eyes had significant haze at final follow-up, although trace haze was found in four cPRK eyes and six LASEK eyes (p = 0.44). However, at 6 weeks after surgery, zero cPRK eyes and nine LASEK eyes (p < 0.05) had significant haze. At final follow-up, 63 % of cPRK eyes and 35 % of LASEK eyes (p = 0.17) were within ±1.0 D of intended refraction. Finally, 100 % of cPRK patients and 92 % of LASEK patients (p = 0.87) were satisfied or very satisfied with the surgery at final follow-up. cPRK and LASEK seemed safe and with high patient satisfaction 4 to 7 years after surgery for high myopia. However, cPRK was more effective than LASEK in reducing initial significant corneal haze.

  1. [Reduction of decentration after LASIK using a modified eye tracker ring for the MEL-70 excimer laser].

    Science.gov (United States)

    Schulze, S; Nietgen, G; Sekundo, W

    2004-07-01

    The aim of this study was to determine and compare the rate of eccentric laser ablation after LASIK depending on the eye tracker ring used. All LASIK treatments were carried out using the MEL-70 flying spot excimer laser (Zeiss-Meditec, Jena). The flap was produced using a Corneal Shaper trade mark or Hansatome trade mark Microkeratome (B and L Surgical, Heidelberg). Initially we used an 11 mm eye tracker ring without hinge protector. At the end of February 2001 this ring was replaced by a 10 mm and a 9.5 mm ring with built-in hinge protector. An additional modification was introduced by us: at 1 mm separations little teeth-like spikes were engraved into the eyeward side of the ring, thus stabilising the position of the ring on the globe and allowing free liquid to flow through the spaces between each spike. The built-in calibration system of the corneal topography (TMS 3, Tomey, Erlangen) from patients with a follow-up of one month or longer was used to determine the distance between the centre of the ablation zone from the fixation point. In group I patients (old ring) 42 eyes were treated. In 4 eyes ablation was perfect, in 21 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 11 eyes 0.51 to 0.99 mm and in 5 eyes 1.1 to 1.49 mm whereas one eye showed a decentred ablation of 1.53 mm. In group II (new ring) 42 eyes were investigated also. In 11 eyes ablation was perfect, in 20 eyes the ablation centre was located 0.1 to 0.49 mm from the fixation point, in 10 eyes 0.5 to 0.99 mm and one eye had an eccentric ablation of 1.28 mm from the fixation point. The further development of our eye tracker ring for the MEL-70 laser considerably reduced the rate of decentred ablations. An enhanced grip of the ring onto the globe reduces a slow slide during the laser procedure.

  2. Radiation structurization borosilicates in the region of small dozes

    International Nuclear Information System (INIS)

    Gadzhieva, N.N.; Melikova, S.Z.

    2007-01-01

    Full text: Borosilicates are one of perspective materials who are characterized by high thermal and radiating stability. Owing to these properties they are widely applied as constructional materials in reactor technologies. The structural condition of a bor in crystal compounds is characterized by two coordination numbers- three and and four. Change of this condition speaks also original properties borosilicate. Studying influence is actual γ-irradiations in the region of rather small dozes on ability change coordination of a B in borosilicate. In the given work results of IR-spectroscopic researches initial and radiation-structured borosilicates are presented. With this purpose were investigated borosilicates with maintenance B 2 O 3 in SiO 2 equal 0.5; 1; 1.5; 3; 5 and 10 mas.%, received by a method of sedimentation. Samples irradiated γ-quanta on an isotope source 60 Co with capacity of a doze dD γ /dt=0.80 Gy/s. The absorbed doze made D γ ∼0.5-50 kGy. IR-spectra of reflection initial and γ-irradiated tablets borosilicates measured on spectrophotometer Specord 71 IR (Carl Zeiss) at a room temperature. Optical density of the bands corresponding trigonal and tetrahedric - coordination atoms of a bor and their parity at the various mass maintenance of boric anhydride in SiO 2 before and after γ-irradiation. The absorption bands of asymmetric stretching vibration BO 3 and BO 4 groupings in structure of B 2 O 3 /SiO 2 have maxima at ν=1320 (ν as BO 3 ) and 980 cm -1 (ν as BO 4 ). Studying dose has shown dependences D 1320 /D 980 , that in the region of rather small dozes 0.5 γ 1320 /D 980 of optical densities trigonal and tetrahedric coordination a B it is established, that at the contain B 2 O 3 in SiO 2 /B 2 O 3 ∼1.5 mas.% maximal introduction B 3+ in a lattice oxide silicon is observed

  3. Structure and Novel Biomineralization of Mnemiopsis Leidyi and Beroe Ovata Lithocyte Concretions (lcs) as Revealed by Polarization Lc-Pol Scanning Electron Microscopy (sem) and Electron Dispersion Spectroscopy (eds)

    Science.gov (United States)

    Moss, A.

    2016-02-01

    Ctenophore statocysts have multicellular statoliths borne on the tips of balancer compound cilia (Curr. Biol. 24:R951; Biol. Bull. 227:7). Lithocyte concretions (LCs) were prepared by three methods: 1) statocysts were microsurgically collected and washed w/0.2 µm filtered sea water (FSW), followed by 5 diH2O rinses in a deep well dish (DWD); 2) statocysts were treated with 50% Chlorox/FSW to release the statolith/LCs; 3) statocysts were fixed in 2.5% glutaraldehyde or 1% paraformaldehyde-2.5% glutaraldehyde in 10 mM pH 7.8 HEPES-buffered FSW, and statoliths and LCs microsurgically released. LCs for SEM were glued to stubs, C-stabilized and Pt-coated to a thickness of 8 nm and viewed at 10 kVe. LCs for EDS were applied to carbon tape on aluminum stubs and analyzed by EDS at 3 and 10 kVe. SEM and EDS were performed on a Zeiss Supra 40 VP equipped with an EDS detector controlled by INCA software (Oxford). Results were compared against compounds of known elemental composition. LCs examined by LC-POL revealed no birefringence (BR). LCs viewed by SEM were either a lumpy mass (M. leidyi) or smooth ellipsoid (B. ovata). LCs on carbon tape typically shattered and released overlapping, layered, multi-oriented crystals. EDS of LC crystals from both species collected by all methods lacked Ca, Mn and Mg. Predominant elements were Na, K, O and S in ratios suggesting that LCs contain mixed sodium/potassium sulfates. The unique composition of ctenophore statoliths may have been critical for the 600+ million years persistence of these organisms (J. exp. Biol. 218:592) including survival through multiple global extinctions and related ocean acidifications. Thanks to L. Kerr, R. Oldenbourg, S. Mehta, A. Verma, M. Tran, A. Kuzirian and S. Tamm for stimulating discussion and technical advice. EDS stds compounds were curtesy of L. Amaral-Zettler, J. Huber and K. Gribble (Bay Paul Center/MBL). Funding: AU PIL Program, NSF-EPS-1158862.

  4. Filiform papilla of holstein’s tongue and its relation with the Rhipicephalus microplus tick resistance

    Directory of Open Access Journals (Sweden)

    Cecília José Veríssimo

    2012-12-01

    Full Text Available Several studies describe anatomical, morphological and histological analysis of domestic and wild animals tongue. The tongue is an extendable muscular organ that performs gripping, chewing, and swallowing food actions and executes tasting and mechanical body self-cleaning functions (grooming. The distribution of these tongue characteristics may vary, according to different species, but studies made with different animals classes reveal the filiform papilla acting in mechanical body cleaning function. In order to evaluate these mechanical functions, especially the self-cleaning one, we proposed to investigate filiform papillae length or its base dimensions would be related to the heifers resistance to Rhipicephalus microplus tick. Biopsies were performed in eight (8 Holstein heifers’ tongues, with a 6 mm diameter punch, in the anterior third of tongues, at the distance of 3 cm from its tip. The animals were anesthetized with xylazine hydrochloride 2%, a sedative, analgesic and muscle relaxant and received local anesthetic, hydrochloride 2.0 g lidocaine. After tissue removal, the local lesions received an ointment of triamcinolone acetonide, 1.0 mg g-1. The Holstein heifers were one year and half old and naturally infested with ticks in a paddock situated at “Instituto de Zootecnia”. We monitored their natural infestation by counting females ticks, greater than 4.5 mm, presents in every animal, in four weekly evaluations (from 8 to 28 December – 2011. These samples were submitted to technical process of fixation and dehydration (as required by in the scanning electron microscope study, in the laboratory NAP/MEPA - ESALQ-USP. The papillae were visualized and measured with the aid of the measurement tool between two points of the software in the scanning electron microscope Zeiss LEO 435VP. Statistically analyses were performed by the SPSSP 12.0 program in a complete randomized design. We employed the Oneway method for variance analysis to

  5. SU-F-T-654: Pacemaker Dose Estimate Using Optically Stimulated Luminescent Dosimeter for Left Breast Intraoperative Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Y; Goenka, A; Sharma, A; Wang, L; Cao, Y; Jamshidi, A [Northwell Health, Lake Success, NY (United States)

    2016-06-15

    Purpose: To assess and report the in vivo dose for a patient with a pacemaker being treated in left breast intraoperative radiation therapy (IORT). The ZEISS Intrabeam 50 kVp X-ray beam with a spherical applicator was used. Methods: The optically stimulated luminescent dosimeters (OSLDs) (Landauer nanoDots) were employed and calibrated under the conditions of the Intrabeam 50 kVp X-rays. The nanoDots were placed on the patient at approximately 15 cm away from the lumpectomy cavity both under and above a shield of lead equivalence 0.25 mm (RayShield X-Drape D-110) covering the pacemaker area during IORT with a 5 cm spherical applicator. Results: The skin surface dose near the pacemaker during the IORT with a prescription of 20 Gy was measured as 4.0±0.8 cGy. The dose behind the shield was 0.06±0.01 Gy, demonstrating more than 98% dose reduction. The in vivo skin surface doses during a typical breast IORT at a 4.5 cm spherical applicator surface were further measured at 5, 10, 15, and 20 cm away to be 159±11 cGy, 15±1 cGy, 6.6±0.5 cGy, and 1.8±0.1 cGy, respectively. A power law fit to the dose versus the distance z from the applicator surface yields the dose fall off at the skin surface following z^-2.5, which can be used to estimate skin doses in future cases. The comparison to an extrapolation of depth dose in water reveals an underestimate of far field dose using the manufactory provided data. Conclusion: The study suggests the appropriateness of OSLD as an in vivo skin dosimeter in IORT using the Intrabeam system in a wide dose range. The pacemaker dose measured during the left breast IORT was within a safe limit.

  6. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism

    Directory of Open Access Journals (Sweden)

    Li-Kun Xia

    2018-03-01

    Full Text Available AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs, contrast sensitivity (CS and dry eye parameters after small incision lenticule extraction (SMILE and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE of -8.11±1.09 diopters (D received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI and tear break-up time (TBUT were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13. The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00, and 0.14 D in the SMILE group (t=0.54, P=0.59 from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00, but the coma root mean square (RMS was higher in the SMILE group (0.59±0.26 than in the FS-LASIK group (0.29±0.14, P=0.00. The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long

  7. Avaliação da utilização dos adesivos dentinários na microinfiltração marginal de resinas compostas = Evaluation of use of dentin bond on the marginal microleakege of composites

    Directory of Open Access Journals (Sweden)

    Peixe, Simone

    2006-01-01

    Full Text Available O objetivo deste trabalho foi o de avaliar a microinfiltração marginal em restaurações de resina composta quando utilizados adesivos dentinários de um mesmo fabricante e associação com os adesivos de fabricantes diferentes. Foram realizados 40 preparos classe II tipo slot vertical, com pontas diamantadas 1094 (K. G. Sorensen nas proximais dos terceiros molares. As restaurações foram divididas em 4 grupos; restaurações com Prime & Bond e TPH (G1, Single Bond e TPH (G2, Single Bond e Z 100 (G3, Prime & Bond e Z 100 (G4. Após a confecção das restaurações, estas foram submetidas à ciclagem térmica, em água a 5°C ± 2°C e 55°C ± 2°C, com o tempo de permanência de 30 segundos, num total de 500 ciclos. As amostras foram imersas no corante, nitrato de prata 50%, em temperatura ambiente por 24 horas em câmara escura, sendo posteriormente colocadas em uma solução fotoreveladora sob luz fluorescente por 6 horas. Foram realizados dois cortes no centro da restauração, no sentido ocluso-gengival. A análise da microinfiltração foi realizada em lupa esterioscópica Zeiss com 50 vezes de aumento, seguindo scores de 0 a 3 graus. Os dados obtidos foram submetidos à análise não paramétrica de Kruskal-Wallis, revelando que os valores medianos (G1 = 3; G2 = 3; G3 = 2. 5; G4 = 1 diferem estatisticamente ao nível de significância de 5%. Mediante ao teste de comparação múltipla de Dunn (5% G4 foi superior aos outros grupos em termos de microinfiltração marginal

  8. {sup 23}Na-MRI of recurrent glioblastoma multiforme after intraoperative radiotherapy: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Haneder, Stefan; Buesing, Karen A.; Schoenberg, Stefan O.; Ong, Melissa M. [Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Giordano, Frank A.; Wenz, Frederik [University of Heidelberg, Department of Radiation Oncology, University Medical Center Mannheim, Mannheim (Germany); Konstandin, Simon; Schad, Lothar R. [Heidelberg University, Computer Assisted Clinical Medicine, Mannheim (Germany); Brehmer, Stefanie; Schmiedek, Peter [Heidelberg University, Department of Neurosurgery, University Medical Center Mannheim, Mannheim (Germany)

    2015-03-01

    We report the first case of an intraoperative radiotherapy (IORT) in a patient with recurrent glioblastoma multiforme (GBM) who was followed up with a novel magnetic resonance imaging (MRI) method - {sup 23}Na-MRI - in comparison to a standard contrast-enhanced {sup 1}H-MRI and {sup 18}F-FET-PET. A 56-year-old female patient with diagnosed GBM in July 2012 underwent tumor resection, radiochemotherapy, and three cycles of chemotherapy. After a relapse, 6 months after the initial diagnosis, an IORT was recommended which was performed in March 2013 using the INTRABEAM system (Carl Zeiss Meditec AG, Germany) with a 3-cm applicator and a surface dose of 20 Gy. Early post-operative contrast-enhanced and 1-month follow-up {sup 1}H-MRI and a {sup 18}F-FET-PET were performed. In addition, an IRB-approved {sup 23}Na-MRI was performed on a 3.0-T MR scanner (MAGNETOM TimTrio, Siemens Healthcare, Germany). After re-surgery and IORT in March 2013, only a faint contrast enhancement but considerable surrounding edema was visible at the medio-posterior resection margins. In April 2013, new and progressive contrast enhancement, edema, {sup 23}Na content, and increased uptake in the {sup 18}F-FET-PET were visible, indicating tumor recurrence. Increased sodium content within the area of contrast enhancement was found in the {sup 23}Na-MRI, but also exceeding this area, very similar to the increased uptake depicted in the {sup 18}F-FET-PET. The clearly delineable zone of edema in both examinations exhibits a lower {sup 23}Na content compared to areas with suspected proliferating tumor tissue. {sup 23}Na-MRI provided similar information in the suspicious area compared to {sup 18}F-FET-PET, exceeding conventional {sup 1}H-MRI. Still, {sup 23}Na-MRI remains an investigational technique, which is worth to be further evaluated. (orig.)

  9. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    Science.gov (United States)

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  10. CUSTOM OPTIMIZATION OF INTRAOCULAR LENS ASPHERICITY

    Science.gov (United States)

    Koch, Douglas D.; Wang, Li

    2007-01-01

    Purpose To investigate the optimal amount of ocular spherical aberration (SA) in an intraocular lens (IOL) to maximize optical quality. Methods In 154 eyes of 94 patients aged 40 to 80 years, implantation of aspheric IOLs was simulated with different amounts of SA to produce residual ocular SA from −0.30 μm to +0.30 μm. Using the VOL-CT program (Sarver & Associates, Carbondale, Illinois), corneal wavefront aberrations up to 6th order were computed from corneal topographic elevation data (Humphrey Atlas, Carl Zeiss Meditec, Inc, Dublin, California). Using the ZernikeTool program (Advanced Medical Optics, Inc, Santa Ana, California), the polychromatic point spread function with Stiles-Crawford effect was calculated for the residual ocular higher-order aberrations (HOAs, 3rd to 6th order, 6-mm pupil), assuming fully corrected 2nd-order aberrations. Five parameters were used to quantify optical image quality, and we determined the residual ocular SA at which the maximal image quality was achieved for each eye. Stepwise multiple regression analysis was performed to assess the predictors for optimal SA of each eye. Results The optimal SA varied widely among eyes. Most eyes had best image quality with low amounts of negative SA. For modulation transfer function volume up to 15 cycles/degree, the amount of optimal SA could be predicted based on other HOAs of the cornea with coefficient of multiple determination (R2) of 79%. Eight Zernike terms significantly contributed to the optimal SA in this model; the order of importance to optimal SA from most to least was: Z60, Z62, Z42, Z53, Z64, Z3−1, Z33, and Z31. For the other 4 measures of visual quality, the coefficients of determination varied from 32% to 63%. Conclusion The amount of ocular SA producing best image quality varied widely among subjects and could be predicted based on corneal HOAs. Selection of an aspheric IOL should be customized according to the full spectrum of corneal HOAs and not 4th-order SA alone

  11. Ca(2+ release events in cardiac myocytes up close: insights from fast confocal imaging.

    Directory of Open Access Journals (Sweden)

    Vyacheslav M Shkryl

    Full Text Available The spatio-temporal properties of Ca(2+ transients during excitation-contraction coupling and elementary Ca(2+ release events (Ca(2+ sparks were studied in atrial and ventricular myocytes with ultra-fast confocal microscopy using a Zeiss LSM 5 LIVE system that allows sampling rates of up to 60 kHz. Ca(2+ sparks which originated from subsarcolemmal junctional sarcoplasmic reticulum (j-SR release sites in atrial myocytes were anisotropic and elongated in the longitudinal direction of the cell. Ca(2+ sparks in atrial cells originating from non-junctional SR and in ventricular myocytes were symmetrical. Ca(2+ spark recording in line scan mode at 40,000 lines/s uncovered step-like increases of [Ca(2+]i. 2-D imaging of Ca(2+ transients revealed an asynchronous activation of release sites and allowed the sequential recording of Ca(2+ entry through surface membrane Ca(2+ channels and subsequent activation of Ca(2+-induced Ca(2+ release. With a latency of 2.5 ms after application of an electrical stimulus, Ca(2+ entry could be detected that was followed by SR Ca(2+ release after an additional 3 ms delay. Maximum Ca(2+ release was observed 4 ms after the beginning of release. The timing of Ca(2+ entry and release was confirmed by simultaneous [Ca(2+]i and membrane current measurements using the whole cell voltage-clamp technique. In atrial cells activation of discrete individual release sites of the j-SR led to spatially restricted Ca(2+ release events that fused into a peripheral ring of elevated [Ca(2+]i that subsequently propagated in a wave-like fashion towards the center of the cell. In ventricular myocytes asynchronous Ca(2+ release signals from discrete sites with no preferential subcellular location preceded the whole-cell Ca(2+ transient. In summary, ultra-fast confocal imaging allows investigation of Ca(2+ signals with a time resolution similar to patch clamp technique, however in a less invasive fashion.

  12. Comparing whole slide digital images versus traditional glass slides in the detection of common microscopic features seen in dermatitis

    Directory of Open Access Journals (Sweden)

    Nikki S Vyas

    2016-01-01

    Full Text Available Background: The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. Methods: Hematoxylin and eosin and periodic acid-Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany. Six pathologists assessed 50-71 digital slides. We recorded objective magnification, total time, and detection of the following: Mast cells; eosinophils; plasma cells; pigmented macrophages; melanin in the epidermis; fungal bodies; neutrophils; civatte bodies; parakeratosis; and sebocytes. This process was repeated using the corresponding glass slides after 3 weeks. The diagnosis was not required. Results: The mean time to assess digital slides was 176.77 s and 137.61 s for glass slides (P < 0.001, 99% confidence interval [CI]. The mean objective magnification used to detect features using digital slides was 18.28 and 14.07 for glass slides (P < 0.001, 99.99% CI. Parakeratosis, civatte bodies, pigmented macrophages, melanin in the epidermis, mast cells, eosinophils, plasma cells, and neutrophils, were identified at lower objectives on glass slides (P = 0.023-0.001, 95% CI. Average intraobserver concordance ranged from κ = 0.30 to κ = 0.78. Features with poor to fair average concordance were: Melanin in the epidermis (κ = 0.15-0.58; plasma cells (κ = 0.15-0.49; and neutrophils (κ = 0.12-0.48. Features with moderate average intrapathologist concordance were: parakeratosis (κ = 0.21-0.61; civatte bodies (κ = 0.21-0.71; pigment-laden macrophages (κ = 0.34-0.66; mast cells (κ = 0.29-0.78; and eosinophils (κ = 0.31-0.79. The average intrapathologist concordance was good for sebocytes (κ = 0.51-1.00 and fungal bodies (κ = 0.47-0.76. Conclusions: Telepathology using digital slides scanned at ×20 is sufficient for detection of histopathologic features routinely encountered in

  13. SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

    International Nuclear Information System (INIS)

    Thoelking, J; Yuvaraj, S; Jens, F; Lohr, F; Wenz, F; Wertz, H; Wertz, H

    2015-01-01

    verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant

  14. the first experience of phakoemulsification with vacuum trabeculoplasty ab interno for combined cataract and glaucoma

    Directory of Open Access Journals (Sweden)

    V. N. Trubilin

    2014-07-01

    Full Text Available Purpose: to describe of a new effective method of combined treatment of patients with primary open- angle glaucoma with mod- erately elevated intraocular pressure and cataract.Methods: Studies have been conducted among 30 patients (30 eyes from 46 to 85 years with a combination of cataract of varying degrees of maturity and open-angle glaucoma of different stages. In addition to the standard techniques there were used special clini- cal and functional methods of research: optical cogerent tomography of the anterior segment of the eye Visante OCt (Carl Zeiss, Ger- many, glaucomatous cupping and thickness of nerve fibers study using confocal scanning laser ophthalmoscope HRt II (Heidelberg Engineering, Germany. In accordance with the target patients were divided into 2 groups: the basic group consisted of 15 patients (15 eyes aged 63 to 76 years with primary open angle glaucoma of 1-2 stages and cataracts of varying degrees of maturity. In both groups there was performed the ultrasonic phakoemulsification of the lens on the phakoemulsificator Infinity (Alcon, US.Results: the analysis of intraocular pressure measurements showed that among patients from I and II group eye pressure had a downward trend in the early postoperative period, however, the average dynamics of reduction of the intraocular pressure in the group of patients where phakoemulsification and vacuum trabeculoplasty ab interno performed was higher than in the control group. In the gonioscopy of the corner of the anterior chamber the clinical presentation remained stable throughout the period of observation. In the postoperative period among patients in the main observation group according to OCt it was noted changing the depth of the anterior chamber of eye towards its increase by an average of 1.39 mm, as well as increasing the angle of the anterior chamber at an average of 9.98.Conclusion: Phakoemulsification with IOL implantation combined with vacuum trabeculoplasty ab interno is

  15. Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.

    Science.gov (United States)

    Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin

    2015-12-01

    To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at

  16. the first experience of phakoemulsification with vacuum trabeculoplasty ab interno for combined cataract and glaucoma

    Directory of Open Access Journals (Sweden)

    V. N. Trubilin

    2012-01-01

    Full Text Available Purpose: to describe of a new effective method of combined treatment of patients with primary open- angle glaucoma with mod- erately elevated intraocular pressure and cataract.Methods: Studies have been conducted among 30 patients (30 eyes from 46 to 85 years with a combination of cataract of varying degrees of maturity and open-angle glaucoma of different stages. In addition to the standard techniques there were used special clini- cal and functional methods of research: optical cogerent tomography of the anterior segment of the eye Visante OCt (Carl Zeiss, Ger- many, glaucomatous cupping and thickness of nerve fibers study using confocal scanning laser ophthalmoscope HRt II (Heidelberg Engineering, Germany. In accordance with the target patients were divided into 2 groups: the basic group consisted of 15 patients (15 eyes aged 63 to 76 years with primary open angle glaucoma of 1-2 stages and cataracts of varying degrees of maturity. In both groups there was performed the ultrasonic phakoemulsification of the lens on the phakoemulsificator Infinity (Alcon, US.Results: the analysis of intraocular pressure measurements showed that among patients from I and II group eye pressure had a downward trend in the early postoperative period, however, the average dynamics of reduction of the intraocular pressure in the group of patients where phakoemulsification and vacuum trabeculoplasty ab interno performed was higher than in the control group. In the gonioscopy of the corner of the anterior chamber the clinical presentation remained stable throughout the period of observation. In the postoperative period among patients in the main observation group according to OCt it was noted changing the depth of the anterior chamber of eye towards its increase by an average of 1.39 mm, as well as increasing the angle of the anterior chamber at an average of 9.98.Conclusion: Phakoemulsification with IOL implantation combined with vacuum trabeculoplasty ab interno is

  17. Development of an expert system for the simulation model for casting metal substructure of a metal-ceramic crown design.

    Science.gov (United States)

    Matin, Ivan; Hadzistevic, Miodrag; Vukelic, Djordje; Potran, Michal; Brajlih, Tomaz

    2017-07-01

    Nowadays, the integrated CAD/CAE systems are favored solutions for the design of simulation models for casting metal substructures of metal-ceramic crowns. The worldwide authors have used different approaches to solve the problems using an expert system. Despite substantial research progress in the design of experts systems for the simulation model design and manufacturing have insufficiently considered the specifics of casting in dentistry, especially the need for further CAD, RE, CAE for the estimation of casting parameters and the control of the casting machine. The novel expert system performs the following: CAD modeling of the simulation model for casting, fast modeling of gate design, CAD eligibility and cast ability check of the model, estimation and running of the program code for the casting machine, as well as manufacturing time reduction of the metal substructure. The authors propose an integration method using common data model approach, blackboard architecture, rule-based reasoning and iterative redesign method. Arithmetic mean roughness values was determinated with constant Gauss low-pass filter (cut-off length of 2.5mm) according to ISO 4287 using Mahr MARSURF PS1. Dimensional deviation between the designed model and manufactured cast was determined using the coordinate measuring machine Zeiss Contura G2 and GOM Inspect software. The ES allows for obtaining the castings derived roughness grade number N7. The dimensional deviation between the simulation model of the metal substructure and the manufactured cast is 0.018mm. The arithmetic mean roughness values measured on the casting substructure are from 1.935µm to 2.778µm. The realized developed expert system with the integrated database is fully applicable for the observed hardware and software. Values of the arithmetic mean roughness and dimensional deviation indicate that casting substructures are surface quality, which is more than enough and useful for direct porcelain veneering. The

  18. [Normal macular thickness and volume using spectral domain optical coherence tomography in a reference population].

    Science.gov (United States)

    Solé González, L; Abreu González, R; Alonso Plasencia, M; Abreu Reyes, P

    2013-09-01

    To establish normal values of macular thickness and volume obtained by the Cirrus SD-OCT (Carl ZeissMeditec, Dublin, CA, U.S.A.). Secondly, to assess the association between macular thickness and volume, sex and age. A prospective study was conducted on patients who were seen in a hospital Retina Unit, and who only had retinal disease in one eye. All the Macular Cube 512 × 128 scan protocols were performed by the same operator. Only the healthy eye was scanned in each patient. A total of 100 eyes of 100 patients were analysed. The mean central foveal thickness was 261.31 ± 17.67 microns, and was significantly (P<.05) higher in males (267.74 ± 16.98 microns) than in females (255.60 ± 16.40 microns). The mean obtained for the volume of the cube was 10.09 ± 0.37mm 3, and the mean thickness of 280.33 ± 10.34 cube um, with no statistically significant differences between gender being found (P<.05). The mean macular thickness is less at central level, increases in the inner perifoveal ring, and then decreases in the outer perifoveal ring. Furthermore, of all quadrants the greatest thickness was the nasal (328.27 ± 12.96 microns), followed by the upper (326.27 ± 11.89 microns), lower (322.53 ± 12.37mm) sectors, with the temporal sector being the thinnest (313.35 ± 14.20 microns). The mean age of the patients was 60.86 ± 14 years. The mean central foveal thickness and the thickness of the inner perifoveal ring are significantly higher in men than in women. Both the mean volume and thickness of the cube, as well as nasal and inner superior sectors decrease with age, being significantly only in women. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  19. Straight sinus: ultrastructural analysis aimed at surgical tumor resection.

    Science.gov (United States)

    Amato, Marcelo Campos Moraes; Tirapelli, Luis Fernando; Carlotti, Carlos Gilberto; Colli, Benedicto Oscar

    2016-08-01

    OBJECTIVE Accurate knowledge of the anatomy of the straight sinus (SS) is relevant for surgical purposes. During one surgical procedure involving the removal of part of the SS wall, the authors observed that the venous blood flow was maintained in the SS, possibly through a vein-like structure within the dural sinus or dural multiple layers. This observation and its divergence from descriptions of the histological features of the SS walls motivated the present study. The authors aimed to investigate whether it is possible to dissect the SS walls while keeping the lumen intact, and to describe the histological and ultrastructural composition of the SS wall. METHODS A total of 22 cadaveric specimens were used. The SS was divided into three portions: anterior, middle, and posterior. The characteristics of the SS walls were analyzed, and the feasibility of dissecting them while keeping the SS lumen intact was assessed. The thickness and the number of collagen fibers and other tissues in the SS walls were compared with the same variables in other venous sinuses. Masson's trichrome and Verhoeff's stains were used to assess collagen and elastic fibers, respectively. The data were analyzed using Zeiss image analysis software (KS400). RESULTS A vein-like structure independent of the SS walls was found in at least one of the portions of the SS in 8 of 22 samples (36.36%). The inferior wall could be delaminated in at least one portion in 21 of 22 samples (95.45%), whereas the lateral walls could seldom be delaminated. The inferior wall of the SS was thicker (p < 0.05) and exhibited less collagen and greater amounts of other tissues-including elastic fibers, connective tissue, blood vessels, and nerve fibers (p < 0.05)-compared with the lateral walls. Transmission electron microscopy revealed the presence of muscle fibers at a level deeper than that of the subendothelial connective tissue in the inferior wall of the SS, extending from its junction with the great cerebral vein

  20. In Vitro Comparative Study of Oxygen Plasma Treated Poly(Lactic–Co–Glycolic (PLGA Membranes and Supported Nanostructured Oxides for Guided Bone Regeneration Processes

    Directory of Open Access Journals (Sweden)

    Daniel Torres-Lagares

    2018-05-01

    Full Text Available (1 Background: The use of physical barriers to prevent the invasion of gingival and connective tissue cells into bone cavities during the healing process is called guided bone regeneration. The objective of this in-vitro study was to compare the growth of human osteoblasts on Poly(Lactic–co–Glycolic (PLGA membranes modified with oxygen plasma and Hydroxyapatite (HA, silicon dioxide (SiO2, and titanium dioxide (TiO2 composite nanoparticles, respectively. (2 Methods: All the membranes received a common treatment with oxygen plasma and were subsequently treated with HA nanostructured coatings (n = 10, SiO2 (n = 10 and TiO2 (n = 10, respectively and a PLGA control membrane (n = 10. The assays were performed using the human osteoblast line MG-63 acquired from the Center for Scientific Instrumentation (CIC from the University of Granada. The cell adhesion and the viability of the osteoblasts were analyzed by means of light-field microphotographs of each condition with the inverted microscope Axio Observer A1 (Carl Zeiss. For the determination of the mitochondrial energy balance, the MitoProbe™ JC-1 Assay Kit was employed. For the determination of cell growth and the morphology of adherent osteoblasts, two techniques were employed: staining with phalloidin-TRITC and staining with DAPI. (3 Results: The modified membranes that show osteoblasts with a morphology more similar to the control osteoblasts follow the order: PLGA/PO2/HA > PLGA/PO2/SiO2 > PLGA/PO2/TiO2 > PLGA (p < 0.05. When analysing the cell viability, a higher percentage of viable cells bound to the membranes was observed as follows: PLGA/PO2/SiO2 > PLGA/PO2/HA > PLGA/PO2/TiO2 > PLGA (p < 0.05, with a better energy balance of the cells adhered to the membranes PLGA/PO2/HA and PLGA/PO2/SiO2. (4 Conclusion: The membrane in which osteoblasts show characteristics more similar to the control osteoblasts is the PLGA/PO2/HA, followed by the PLGA/PO2/SiO2.

  1. Bioaccumulation of cadmium by spring barley (Hordeum vulgare L. and its effect on selected physiological and morphological parameters

    Directory of Open Access Journals (Sweden)

    Miriama Kopernická

    2016-01-01

    Full Text Available Heavy metals and other toxic elements in the environment, mainly located in soil and groundwater, have a significant effect on plant and its productivity that has a huge attention in recent years. Accumulation of heavy metals in soil cause toxicity to plants, and contaminate the food chain. The industrial areas, as well as developing countries have been contaminated with high concentration of heavy metals. Main sources of contamination are mining and other industrial processes, as well as military and or lanfills, sludge dumps or waste disposal sites. The heavy metals are very dangerous to environment and pose serious danger to public health by entering throught the food chain or into drinking water. Phytoextraction is one way how to remove the contaminants from soil by plants. Phytoextraction of heavy metals is a technology that has been studied for several years. It is more ecological and cheaper way how to clean our environment.Several plant species are known becauce they hyperaccumulate a high contents of metals from the soil. The accumulators are mainly herbaceous species, crops and nowadays angiosperm trees with a high growth such as poplars or willows. We have focused on the determination of some morphological (lenght and weight of roots and biomass and physiological (contents of dry mass and number of lief stomata characteristics and the determination of the bioaccumulation factor and the translocation factor of cadmium by spring barley (Hordeum vulgare L.. Imprints of leaves were evaluated using an optical microscope Axiostar Plus, Carl Zeiss, lens CP Achromat 40x/0.65, eyepiece PI 10x / 18, Canon Utilities Software Zoom Browser EX 4.6 and hardware Acer Travel Mate 4600, Canon Power Shot A95. The density of stomata was evaluated on an area of 1 mm2. Samples of the dried plants (leaves and roots were mineralized by acid digestion using microwave digestion device MARS X - press 5. The end of determination to obtain the cadmium content was

  2. CLINICAL, HISTOLOGICAL AND RADIOLOGICAL ASPECTS REGARDING THE INFLUENCE OF SOME EXTERNAL FACTORS ON THE PULP-DENTIN COMPLEX

    Directory of Open Access Journals (Sweden)

    C. Giuroiu

    2012-12-01

    Full Text Available The present study aimed at assesssing – by clinical, histological and radiological investigations – the influence of some external factors on the pulp-dentin complex, and at providing a causal interpretation of the structural changes observed. Materials and methods. Clinical and radiological exams were performed on 65 old patients with ages between 60-75, and also on 40 young patients with ages between 20-35, presenting different dental-periodontal pathologies. The pulp-dentin complex was submitted to a morphopathological examination, to highlight the structural changes observed at microscopic level. Fragments of dental pulp were imersed in a 4% formaldehyde solution with phosphate buffer 0.1 M., pH 7.2, for 12 -14 hours, at a temperature of 4ºC, and 3-5 µm thick slices were prepared. The slices were coloured with hematoxylin-eosine (HE, by the trichromic technique – Masson. Photographies were taken with a Zeiss microscope, with Kodak 200 ASA. Results. Significant differences were observed, between the two groups of patients, as to the external factors that produce structural changes on pulp-dentin organ. In the group of young patients dental caries and coronal fillings prevailed, while the group of old patients was mostly associated with atrition and chronic marginal periodontitis. Out of the 40 young patients, 30 presented chronic dental caries (75%, while, among the 65 old patients, only 24 presented dental caries (36.9%. The percentages of coronary fillings between the two study groups were close, which could be considered as one of the causes producing changes in the pulp-dentin organ, following aggresive preparation of cavities, the action of materials used for the protection of pulp-dentin complex or of the materials used for coronry fillings. Conclusions. Dental pulp has a remarkable ability to counteract the action of harmful factors, producing a mineral barrier and stimulating the reparatory processes. Changes in the endodontic

  3. Insights for Planetarium and Museum Educators Revealed by the iSTAR international Study of Astronomical Reasoning Database

    Science.gov (United States)

    Slater, T. F.; Tatge, C. B.; Ratcliff, M.; Slater, S. J.

    2016-12-01

    Dedicated sky watchers through the centuries have long sought to find the best teaching methods to efficiently and effectively transfer vast amounts of accumulated star knowledge to the next generation of sky watchers. Although detailed maps specifying the names and locations of stars have been carefully displayed on spherical globes for thousands of years, it is the 1923 installation of a Zeiss-made, large, mechanical star projector in Munich that is often cited as the first modern projection planetarium for teaching astronomy. In the 1930's, impressive planetariums were installed Chicago, Los Angeles and New York, which then in turn served as a catalyst for additional planetarium construction. Planetarium construction increased rapidly in the United States due to federal funding to schools and museums through the 1958 US National Defense Education Act and the US went from one planetarium in 1930, to six in 1940, to about 100 in 1960, increasing to 200 in 1963, 450 by 1967—even before humans had landed on the Moon—and more than 1,000 by 1975. Today, nearly 3,000 permanent planetarium facilities are available to show the stars and heavenly motions to children and adults alike across the world, with perhaps another thousand portable planetariums adding to the available teaching venues. Simultaneous with their construction, discipline-based astronomy education have been trying to better understand, and ultimately improve, how people learn astronomy in the planetarium. A systematic analysis of planetarium education research articles, dissertations, and theses found in the recently constructed, community-wide, international Study of Astronomical Reasoning iSTAR database at istardatabase.org reveal that many of the systematic studies conducted in the 1960s and 1970s using domes served by servo-mechanical star projects have been reproduced again in recent decades in theaters using digital video projection showing nearly the same results: student-passive, information

  4. International Conference on Solid Films and Surfaces (ICSFS 2014)

    International Nuclear Information System (INIS)

    Achete, C A; Almeida, C M; Cremona, M; Rocca, M; Stavale, F

    2015-01-01

    Brasileira de Ciências, CNPq, CAPES, Inmetro, FEI Company and Carl-Zeiss Company. We are grateful for the commercial exhibition of several leading instrument companies that provided great financial support. We thank Altmann, Bruker, CAMECA, Edwards, Horiba, M and M Vácuo, Oxford Instruments, Renishaw, RHK Technology, and SPECS. (preface)

  5. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism.

    Science.gov (United States)

    Xia, Li-Kun; Ma, Jing; Liu, He-Nan; Shi, Ce; Huang, Qing

    2018-01-01

    To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant ( t =-1.59, P =0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group ( t =5.76, P =0.00), and 0.14 D in the SMILE group ( t =0.54, P =0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group ( P =0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P =0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better

  6. Refractive outcomes of an advanced aspherically optimized profile for myopia corrections by LASIK: a retrospective comparison with the standard aspherically optimized profile

    Directory of Open Access Journals (Sweden)

    Meyer B

    2015-02-01

    Full Text Available Bertram Meyer,1 Georg Sluyterman van Langeweyde,2 Matthias Wottke2 1Augencentrum Köln, Cologne, Germany; 2Carl Zeiss Meditec AG, Jena, Germany Purpose: A retrospective comparison of refractive outcomes of a new, aspherically optimized profile with an enhanced energy correction feature (Triple-A and the conventionally used aspherically optimized profile (ASA, or aberration smart ablation for correction of low-to-high myopia.Setting: Augen-OP-Centrum, Cologne, GermanyDesign: Retrospective nonrandomized comparative studyMethods: A central database at the Augen-OP-Centrum was used to gather retrospective data for low-to-high myopia (up to -10 D. One hundred and seven eyes (56 patients were treated with the ASA profile, and 79 eyes (46 patients were treated with the Triple-A profile. Postoperative outcomes were evaluated at 1 month, 3 months, 6 months, and 1 year follow-up time points.Results: The Triple-A profile showed better predictability indicated by a significantly lower standard deviation of residuals (0.32–0.34 vs 0.36–0.44, Triple-A vs ASA in the 6-month to 1-year period. The Triple-A group had better stability across all time intervals and achieved better postoperative astigmatism improvements with significantly lower scatter. This group achieved better safety at 1 year, with 100% of eyes showing no change or gain in Snellen lines, compared with 97% in the ASA group. A better safety index was observed for the Triple-A group at later time points. The Triple-A group had a better efficacy index and a higher percentage of eyes with an uncorrected Snellen visual acuity of 20/20 or greater at all investigated follow-up time points.Conclusion: The new aspherically optimized Triple-A profile can safely and effectively correct low-to-high myopia. It has demonstrated superiority over the ASA profile in most refractive outcomes. Keywords: Triple-A, wavefront measurements, corneal aberrations, corneal asphericity, ablation profile

  7. Comparison of two optical biometers in intraocular lens power calculation

    Directory of Open Access Journals (Sweden)

    Sheng Hui

    2014-01-01

    Full Text Available Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL power calculations using the new optical low-coherence reflectometry and partial coherence interferometry. Subjects and Methods: The clinical data of 122 eyes of 72 cataract patients were analyzed retrospectively. All patients were measured with a new optical low-coherence reflectometry system, using the LENSTAR LS 900 (Haag Streit AG/ALLEGRO BioGraph biometer (Wavelight., AG, and partial coherence interferometry (IOLMaster V.5.4 [Carl Zeiss., Meditec, AG] before phacoemulsification and IOL implantation. Repeated measurements, as recommended by the manufacturers, were performed by the same examiner with both devices. Using the parameters of axial length (AL, corneal refractive power (K1 and K2, and anterior chamber depth (ACD, power calculations for AcrySof SA60AT IOL were compared between the two devices using five formulas. The target was emmetropia. Statistical analysis was performed using Statistical Package for the Social Sciences software (SPSS 13.0 with t-test as well as linear regression. A P value < 0.05 was considered to be statistically significant. Results: The mean age of 72 cataract patients was 64.6 years ± 13.4 [standard deviation]. Of the biometry parameters, K1, K2 and [K1 + K2]/2 values were significantly different between the two devices (mean difference, K1: −0.05 ± 0.21 D; K2: −0.12 ± 0.20 D; [K1 + K2]/2: −0.08 ± 0.14 D. P <0.05. There was no statistically significant difference in AL and ACD between the two devices. The correlations of AL, K1, K2, and ACD between the two devices were high. The mean differences in IOL power calculations using the five formulas were not statistically significant between the two devices. Conclusions: New optical low-coherence reflectometry provides measurements that correlate well to those of partial coherence interferometry, thus it is a precise device that can be used for the

  8. To repair or not to repair: with FAVOR there is no question

    Science.gov (United States)

    Garetto, Anthony; Schulz, Kristian; Tabbone, Gilles; Himmelhaus, Michael; Scheruebl, Thomas

    2016-10-01

    In the mask shop the challenges associated with today's advanced technology nodes, both technical and economic, are becoming increasingly difficult. The constant drive to continue shrinking features means more masks per device, smaller manufacturing tolerances and more complexity along the manufacturing line with respect to the number of manufacturing steps required. Furthermore, the extremely competitive nature of the industry makes it critical for mask shops to optimize asset utilization and processes in order to maximize their competitive advantage and, in the end, profitability. Full maximization of profitability in such a complex and technologically sophisticated environment simply cannot be achieved without the use of smart automation. Smart automation allows productivity to be maximized through better asset utilization and process optimization. Reliability is improved through the minimization of manual interactions leading to fewer human error contributions and a more efficient manufacturing line. In addition to these improvements in productivity and reliability, extra value can be added through the collection and cross-verification of data from multiple sources which provides more information about our products and processes. When it comes to handling mask defects, for instance, the process consists largely of time consuming manual interactions that are error prone and often require quick decisions from operators and engineers who are under pressure. The handling of defects itself is a multiple step process consisting of several iterations of inspection, disposition, repair, review and cleaning steps. Smaller manufacturing tolerances and features with higher complexity contribute to a higher number of defects which must be handled as well as a higher level of complexity. In this paper the recent efforts undertaken by ZEISS to provide solutions which address these challenges, particularly those associated with defectivity, will be presented. From automation

  9. Protecting of Marble Stone Facades of Historic Buildings Using Multifunctional TiO2 Nanocoatings

    Directory of Open Access Journals (Sweden)

    Mohammad A. Aldoasri

    2017-11-01

    Full Text Available Stone surfaces and façades of historic buildings, due to their predominately outdoor location, suffer from many deterioration factors, including air pollution, soluble salts, relative humidity (RH/temperature, and biodeterioration, which are the main causes of decay. In particular, the façades of the buildings deteriorate with direct exposure to these factors; deformation and disfiguration of superficial decoration and formation of black crusts are often observed on the stones. The development and application of self-cleaning and protection treatments on historical and architectural stone surfaces could be a significant improvement in the conservation, protection and maintenance of Cultural Heritage. A titanium dioxide nanoparticle has become a promising photocatalytic material, owing to its ability to catalyze the complete degradation of many organic contaminants and environmental factors. In this study, TiO2 nanoparticles, dispersed in an aqueous colloidal suspension, were applied directly to historic marble stone surfaces, by spray-coating, in order to obtain a nanometric film over the stone surface. The study started with an investigation of some properties of TiO2 nanoparticles, to assess the feasibility of the use of TiO2 on historic stone and architectural surfaces. Scanning electron microscopy (SEM was, coupled with energy dispersive X-ray (EDX microanalysis, (SEM-EDX, in order to obtain information on coating homogeneity and surface morphology, before and after artificial aging; the activity of the coated surface was evaluated through UV-light exposure, to evaluate photo-induced effects. The changes of molecular structure occurring in treated samples were spectroscopically studied by attenuated total reflection infrared spectroscopy (ATR-FTIR; activity of the hydrophobic property of the coated surface was evaluated by Sterio microscopy, model Zeiss 2010 from Munich, Germany, equipped with photo camera S23 under 80X magnification. The

  10. EDITORIAL: Electron Microscopy and Analysis Group Conference 2011 (EMAG 2011)

    Science.gov (United States)

    Moebus, Guenter; Walther, Thomas; Brydson, Rik; Ozkaya, Dogan; MacLaren, Ian; Donnelly, Steve; Nellist, Pete; Li, Ziyou; Baker, Richard; Chiu, YuLung

    2012-07-01

    The biennial EMAG conference has established a strong reputation as a key event for the national and international electron microscopy community. In 2011 the meeting was held at The University of Birmingham, and I must first take this opportunity of thanking Birmingham for hosting the conference and for the excellent support we received from the local organisers. As a committee, we are delighted to see that enthusiasm for the EMAG conference series continues to be strong. We received more than 160 submitted abstracts, and 157 delegates attended the meeting. The scientific programme organiser, Ian MacLaren, put together an exciting programme. Plenary lectures were presented by Professor Knut Urban, Dr Frances Ross and Dr Richard Henderson. There were a further 10 invited speakers, from the UK, Continental Europe, Australia, the USA and Japan. The quality of the contributed oral and poster presentations was also very high. EMAG is keen to encourage student participation, and a winner and two runners-up were presented with prizes for the best oral and poster presentations from a student. I am always struck by the scientific quality of the oral and poster contributions and the vibrant discussions that occur both in the formal sessions and in the exhibition space at EMAG. I am convinced that a crucial part of maintaining that scientific quality is the opportunity that is offered of having a paper fully reviewed by two internationally selected referees and published in the Journal of Physics: Conference Series. For many students, this is the first fully reviewed paper they publish. I hope that you, like me, will be struck by the scientific quality of the 87 papers that follow, and that you will find them interesting and informative. Finally I must thank the platinum sponsors for their support of the meeting. These were Gatan, Zeiss, FEI, JEOL and Hitachi. I must also thank the European Microscopy Society for their generous sponsorship and support for the travel costs of

  11. In vivo visualization of photoreceptor layer and lipofuscin accumulation in Stargardt’s disease and fundus flavimaculatus by high resolution spectral-domain optical coherence tomography

    Directory of Open Access Journals (Sweden)

    Giuseppe Querques

    2009-12-01

    Full Text Available Giuseppe Querques, Rosy Prato, Gabriel Coscas, Gisèle Soubrane, Eric H SouiedDepartment of Ophthalmology, Hopital Intercommunal de Creteil, University Paris XII, FranceIntroduction: To assess photoreceptor (PR layer morphology in patients with Stargardt’s disease (STGD and fundus flavimaculatus (FFM using high resolution spectral domain optical coherence tomography (HD-OCT; OCT 4000 Cirrus, Humphrey-Zeiss, San Leandro, CA.Methods: This was a prospective observational case series. Sixteen consecutive patients with STGD and FFM underwent a complete ophthalmologic examination. Optical coherence tomography examination was performed with HD-OCT, a high-speed (27,000 axial scans per second OCT system using spectral/Fourier domain detection, with an axial image resolution of 5 µm.Results: A total of 31 eyes were included in the study. Transverse loss of the PR layer in the foveal region was shown by HD-OCT. Twenty eyes with clinically evident central atrophy had a disruption of either the Verhoeff‘s membrane (VM or the layer corresponding to the interface of inner segment (IS and outer segment (OS of PR in the foveal region. Among these eyes, 12/20 eyes had a loss of the PR layer (loss of both VM and IS-OS interface in the foveal region. Eleven eyes (11/31 without clinically evident central atrophy had an intact interface of IS and OS of PR centrally. Moreover, we observed hyperreflective deposits: type 1 lesions located within the retinal pigment epithelium (RPE layer and at the level of the outer segments of PR, and type 2 lesions located at the level of the outer nuclear layer and clearly separated from the RPE layer. Type 1 lesions alone were associated with absence of loss of the PR layer in the foveal region in all eyes; type 2 lesions were always associated with presence of type 1 lesions, and often (8/12 eyes associated with loss of the PR layer within the foveal region. Mean best-corrected visual acuity (BCVA was significantly

  12. SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Thoelking, J; Yuvaraj, S; Jens, F; Lohr, F; Wenz, F; Wertz, H; Wertz, H [University Medical Center Mannheim, University of Heidelberg, Mannheim, Baden-Wuerttemberg (Germany)

    2015-06-15

    verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant.

  13. [Development of a standardized evaluation system for cataracta complicata in retinitis pigmentosa].

    Science.gov (United States)

    Auffarth, G U; Faller, U; Tetz, M R; Krastel, H; Völcker, H E

    1997-07-01

    Retinitis pigmentosa (RP) is associated with the formation of a posterior subcapsular cataract (PSC). As only a small part of the crystalline lens is usually affected, it is sometimes difficult to determine to what extent the visual loss is caused by the PSC alone. The methodology was developed in analogy to a scoring system for posterior capsule opacification by Tetz et al. Following dilation of the pupil, standardized photographs of the anterior segments were obtained utilizing a Zeiss photoslitlamp model 40 SL/P. The PSC was scored by evaluating retroillumination photographs. The individual PSC index was calculated by multiplying the density of the opacification (graded from 0 to 4) by the area involved in the central 4 mm zone of the pupil (calculated between 0 and 1). For testing the reliability of the evaluation system in part 1 of this study, 11 RP patients with different grades of PSC were examined by three independent observers. In part 2 of this study 37 eyes of 24 RP patients, aged 47.2 +/- 11.8 years, were evaluated and the PSC index was correlated with different parameters (visual acuity, age, visual fields, eletroretinography). RESULTS PART 1: The cataract-density grades were between 1 and 4 in the 11 patients. In relation to the central 4-mm pupillary zone between 13 and 100% of the area were opacified. Cataract indices (density x area) were between 0.13 and 4.0 (Mean values: Examiner 1:1.41 +/- 1.49; Examiner 2:1.28 +/- 1.46; Examiner 3:1.22 +/- 1.44; differences not significant: P = 0.77). PART 2: After an average duration of RP of 23 years, the average cataract index of the 24 patients was 1.72 +/- 1.35. There was no correlation between cataract index and ERG or visual fields (r 0.4); however, there was a good correlation to visual acuity (r = -0.72; P = 0.0001). Patients with early onset of RP (before 20th year of life) presented on average with an higher cataract index (2.06 +/- 1.67) compared to patients with late manifestation (0.61 +/- 0

  14. Accuracy Potential and Applications of MIDAS Aerial Oblique Camera System

    Science.gov (United States)

    Madani, M.

    2012-07-01

    Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System) is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees) cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels) with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm) and (50 mm/50 mm)) were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance) for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining systematic

  15. PREFACE: International Conference on Solid Films and Surfaces (ICSFS 2014)