WorldWideScience

Sample records for yttrium-aluminium-garnet ho yag

  1. Efficacy of holmium. Yttrium-aluminium-garnet (Ho: YAG) laser therapy for arthroscopic synovectomy of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Inoue, Yasuo; Inoue, Kazuhiko; Kanbe, Katsuaki

    2008-01-01

    To clarify the efficacy of holmium: yttrium-aluminium-garnet (Ho: YAG) laser therapy for arthroscopic synovectomy of rheumatoid arthritis (RA), we treated 13 shoulders of 11 RA patients of whom 1 was stage I, 7 stage II, 2 stage III, and 1 stage IV. The duration of RA is 4.6 years on average and the follow-up period is an average of 14 months. The Ho: YAG laser was set at 10 Watt (W) to treat the bone erosion areas so as to reach the deep zones of the pannus in order to resect the synovium. We compared C-reactive protein (CRP), Disease activity score (DAS) 28 and magnetic resonance image (MRI) findings before and after surgery. We cultured primary synovial cells to assay cytokine production of interleukin (IL)-1β, IL-6 and tumor necrosis factor (TNF)-α. Morphological examination was performed after treatment with the Ho: YAG laser at 0, 1, 5, 10, 15 and 20 W. We found villous synovium proliferation with vascularity in the rotator interval and supra spinatus tendon in the shoulder joints. In the subacromial bursa, yellow fat tissue and white fibrous soft tissue were detected in almost all shoulders. After synovectomy using the Ho: YAG laser, CRP decreased from an average of 3.6 to 0.8 and DAS28 also decreased from an average of 5.4 to 3.7 at 14 months after surgery. MRI showed decreased panni with synovium and did not precede joint destruction after 14 months in 10 shoulders out of 13 (77%). At 20 W of the Ho: YAG laser treatment, the synovial cells shrank as in apoptosis and the number of cells also decreased. Laser treatment also resulted in the following significant changes: TNF-α production increased at 1, 10, 15 and 20 W (compared with 0 W) but not dose dependently; IL-1β and IL-6 increased up to 10 W (compared with 0 W) but decreased at 15 and 20 W (compared with 10 W). In morphological examination, after treatment with the Ho: YAG laser at 15 W, the synovial cells expanded and the number of cells decreased. Therefore, Ho: YAG laser therapy is effective

  2. Sol gel synthesis for preparation of yttrium aluminium garnet

    NARCIS (Netherlands)

    Vrolijk, J.W.G.A.; Willems, J.W.M.M.; Metselaar, R.; With, de G.; Terpstra, R.A.; Metselaar, R.

    1989-01-01

    Sol-gel—synthesis for preparation of pure yttrium aluminium garnet powder with small grain size is subject of this ongoing study. Starting materials were sulfates and chlorides of yttrium and aluminium. To obtain pure YAG (Y3A1SO1Z) pH during hydrolysis as well as temperature during calcination and

  3. Short-pulse neodymium:yttrium-aluminium garnet (Nd:YAG 1064nm) laser irradiation photobiomodulates mitochondria activity and cellular multiplication of Paramecium primaurelia (Protozoa).

    Science.gov (United States)

    Amaroli, Andrea; Benedicenti, Alberico; Ravera, Silvia; Parker, Steven; Selting, Wayne; Panfoli, Isabella; Benedicenti, Stefano

    2017-10-01

    Few studies exist to explore the potential photobiomodulation (PBM) effect of neodymium:yttrium-aluminium garnet (Nd:YAG) laser irradiation using a flat-top handpiece delivery system. In this study, we explored the photobiomodulation effect of that laser, on Paramecium primaurelia. The parameters for the different study groups were: 0.50W, 10Hz, 100msp, 30J/cm 2 ; 0.75W, 10Hz, 100msp, 45J/cm 2 ; 1.00W, 10Hz, 100msp, 60J/cm 2 ; 1.25W, 10Hz, 100msp, 75J/cm 2 and 1.50W, 10Hz, 100msp, 90J/cm 2 . Our results suggest that only the parameter 0.5W, 10Hz, 100msp, 30J/cm 2 positively photobiomodulates the Paramecium cells inducing an increment in oxygen consumption, endogenous ATP synthesis and fission rate rhythm. Applying the laser energy with parameters of 1.25W, 10Hz, 100msp, 75J/cm 2 and 1.50W, 10Hz, 100msp, 90J/cm 2 , induce adverse effect on the Paramecium cells, which protect themselves through the increase in Heat Shock Protein-70 (HSP70). The data presented in our work support our assumption that, when using appropriate parameters of irradiation, the 1064nm Nd:YAG laser with flat-top handpiece could be a valuable aid for effective clinical application of PBM. Copyright © 2017 Elsevier GmbH. All rights reserved.

  4. Thulium-yttrium-aluminium-garnet (Tm:YAG) laser treatment of penile cancer: oncological results, functional outcomes, and quality of life.

    Science.gov (United States)

    Musi, Gennaro; Russo, Andrea; Conti, Andrea; Mistretta, Francesco A; Di Trapani, Ettore; Luzzago, Stefano; Bianchi, Roberto; Renne, Giuseppe; Ramoni, Stefano; Ferro, Matteo; Matei, Deliu Victor; Cusini, Marco; Carmignani, Luca; de Cobelli, Ottavio

    2018-02-01

    To evaluate the oncological and functional outcomes of patients diagnosed with penile cancer undergoing conservative treatment through thulium-yttrium-aluminium-garnet (Tm:YAG) laser ablation. Twenty-six patients with a penile lesion underwent ablation with a RevoLix 200 W continuous-wave laser. The procedure was carried out with a pen-like laser hand piece, using a 360 μm laser fiber and 15-20 W of power. Median (IQR) follow-up time was 24 (15-30) months. Recurrence rate and post-operative sexual function were assessed. Median age at surgery was 61 years. Median (inter quartile range) size of the lesions was 15 [10-20] mm. Overall, 11 (47.8%) and 12 (52.2%) at the final pathology presented in situ and invasive squamous cell carcinoma (SCC), respectively. The final pathological stage was pTis, pT1a, pT2, and pT3 in 11 (47.8%), 7 (30.4%), 3 (13.0%), and 2 (8.7%) patients, respectively. Moreover, four (17.4%) patients had a recurrence of which three (13.0%) and one (4.3%) patients developed an invasive or in situ recurrence, respectively. After treatment 6 (26.1%) patients reported a conserved penile sensitivity, while 13 (56.5%) and 4 (17.4%) patients experienced a better or worse sensitivity after ablation, respectively. Post-treatment sexual activity was achieved within the first month after laser ablation in 82.6% of the patients. Early stage penile carcinomas can be effectively treated with an organ preservation strategy. Tm:YAG conservative laser treatment is easy, safe and offers good functional outcome, with a minor impact on patient's quality of life.

  5. Tattoo removal by Q-switched yttrium aluminium garnet laser

    DEFF Research Database (Denmark)

    Hutton Carlsen, K; Esmann, J; Serup, J

    2017-01-01

    BACKGROUND: Tattoo removal by Q-switched yttrium aluminium garnet (YAG) lasers is golden standard; however, clients' satisfaction with treatment is little known. OBJECTIVE: To determine clients' satisfaction with tattoo removal. METHODS: One hundred and fifty-four tattoo removal clients who had...... relative to colour of tattoo on a scale from 0 (no effect) to 10 (complete removal) scored a mean of blue 9.5, black 9.4, yellow 8.9, red 8.8 and green 6.5. Clients were dissatisfied with green pigment remnants, which could mimic bruising. One hundred and twenty-nine clients (84%) experienced moderate...

  6. Coprecipitation of yttrium and aluminium hydroxide for preparation of yttrium aluminium garnet

    NARCIS (Netherlands)

    Vrolijk, J.W.G.A.; Willems, J.W.M.M.; Metselaar, R.

    1990-01-01

    Coprecipitation of yttrium and aluminium hydroxide for the preparation of pure yttrium aluminium garnet (YAG) powder with small grain size is the subject of this study. Starting materials are sulphates and chlorides of yttrium and aluminium. To obtain pure YAG (Y3Al5O12), the pH during flocculation

  7. Preparation and characterization of Yttrium-Aluminium garnet (Y3Al5O12)

    International Nuclear Information System (INIS)

    Ruzicka, J.; Niznansky, D.; Houzvicka, J.; Nikl, M.; Cerny, R.

    2009-01-01

    This work deals with the preparation of powders and transparent yttrium aluminium garnet (Y 3 Al 5 O 12 - YAG) from nanopowders. Stoichiometric amounts of nanocrystalline Al 2 O 3 and Y 2 O 3 were mixed and chemically pretreated using different basic agents and using ultrasonic bath. Resulting mixture was dried, pressed and heated up to 1750°C. Final material was characterized by X-ray diffraction, DTA and optical and electron microscopy

  8. Microstructure and defect chemistry of yttrium aluminium garnet ceramics

    International Nuclear Information System (INIS)

    Schuh, L.H.

    1989-01-01

    This thesis describes basic aspects concerning the defect chemistry and the microstructure of yttrium aluminium garnet ceramics. The work consists of three parts: a literature study, an experimental part and a section giving computer simulation data of defects. (author). 320 refs.; 68 figs.; 72 schemes; 32 tabs

  9. Kinetics and mechanism of the low-temperature yttrium-aluminium garnet synthesis

    International Nuclear Information System (INIS)

    Ivakin, Yu.D.; Danchevskaya, M.N.; Yanchenko, P.A.; Murav'eva, G.P.

    2000-01-01

    Kinetics and formation mechanism of finely crystalline yttrium-aluminium garnet (YAG) during hydrothermal and hot steam treatment of stoichiometric mixture of oxides in the range of temperature 200-400 Deg C and pressures of 1.5-26 MPa were studied. It is ascertained that formation of YAG occurs via intermediate stage of Y(OH) 3 structure formation, whereas the aluminia component is X-ray amorphous. Kinetics of YAG formation is described by the equation of solid phase transformation with the limiting stage of nucleation. The YAG formed contains 7-5 % of water, which corresponds to hydrogarnet structure. Unit cell parameters of the YAG samples synthesized are somewhat high and after heating up to 1200 Deg C they decrease [ru

  10. Determination of rare earth element content in yttrium aluminium garnet crystals by absorption spectrophotometry method

    International Nuclear Information System (INIS)

    Mejl'man, M.L.; Kolomijtsev, A.I.; Baskakova, Z.M.; Bagdasarov, Kh.S.; Kevorkov, A.M.

    1985-01-01

    Possibility of determination of relative and absolute contents of impurity trivalent REE ions in yttrium aluminium garnet of (YAG) monocrystals has been studied by the absorption spectrophotometry method. Absorption spectra in UV and visible regions YAG monocrystals doped by REE are studied. For each admixture the characteristic lines or absorption bands not overlapping with lines of other admixtures are defined and investigated. The extinction coefficients of characteristic lines are determined which allow one to measure absolute REE admixture concentrations in garnet crystals. A conclusion is drawn that the absorption spectrophotometry method permits to measure REE admixture content in YAG monocrystals within the concentration range of approximately 1x10sup(-3)-5 mas. % with an accuracy not less than 20% (with sample thickness of approximately 1 cm)

  11. Tattoo removal by Q-switched yttrium aluminium garnet laser: client satisfaction.

    Science.gov (United States)

    Hutton Carlsen, K; Esmann, J; Serup, J

    2017-05-01

    Tattoo removal by Q-switched yttrium aluminium garnet (YAG) lasers is golden standard; however, clients' satisfaction with treatment is little known. To determine clients' satisfaction with tattoo removal. One hundred and fifty-four tattoo removal clients who had attended the private clinic 'Centre for Laser Surgery', Hellerup, Denmark, from 2001 to 2013 completed a questionnaire concerning outcome expectations, level of pain experiences and satisfaction with tattoo removal. The laser surgeon and his team were blinded from data handling. The study design included a minimum 2-year postlaser treatment observation period from 2013 to 2015. Overall, clients were satisfied with their laser treatment; 85% assessed their treatment and results to be acceptable to superb, while 15% assessed their treatment and results to be inferior to unacceptable. Effectiveness relative to colour of tattoo on a scale from 0 (no effect) to 10 (complete removal) scored a mean of blue 9.5, black 9.4, yellow 8.9, red 8.8 and green 6.5. Clients were dissatisfied with green pigment remnants, which could mimic bruising. One hundred and twenty-nine clients (84%) experienced moderate to extreme pain during treatment. Twenty-eight (20%) developed minor scarring. There were many reasons for tattoo removal; e.g. stigmatisation (33%), conspicuousness (29%) and poor artistic quality (22%). One hundred and two clients had expected complete removal of tattoos without a blemish, expectations that were only partly fulfilled. During the treatment period, clients adjusted expectations and adapted more realistic views of outcomes. The majority of clients were satisfied with Q-switched YAG laser removal of tattoos despite high pretreatment expectations which were only partly met. The study supports YAG lasers for tattoo removal as acceptable therapy of today, with room for new approaches. © 2017 European Academy of Dermatology and Venereology.

  12. Erbium-doped yttrium aluminium garnet ablative laser treatment for endogenous ochronosis.

    Science.gov (United States)

    Chaptini, Cassandra; Huilgol, Shyamala C

    2015-08-01

    Ochronosis is a rare disease characterised clinically by bluish-grey skin discolouration and histologically by yellow-brown pigment deposits in the dermis. It occurs in endogenous and exogenous forms. Endogenous ochronosis, also known as alkaptonuria, is an autosomal recessive disease of tyrosine metabolism, resulting in the accumulation and deposition of homogentisic acid in connective tissue. We report a case of facial endogenous ochronosis and coexistent photodamage, which was successfully treated with erbium-doped yttrium aluminium garnet laser resurfacing and deep focal point treatment to remove areas of residual deep pigment. © 2014 The Australasian College of Dermatologists.

  13. Phonon-impurity relaxation and acoustic wave absorption in yttrium-aluminium garnet crystals with impurities

    International Nuclear Information System (INIS)

    Ivanov, S.N.; Kotelyanskij, I.M.; Medved', V.V.

    1983-01-01

    The experimental results of investigations of the influence of substitution impurities in the yttrium-aluminium garnet lattice on absorption of high-frequency acoustic waves are presented. It is shown that the phonon-impurity relaxation processses affect at most the wave absorption and have resonance character when the acoustic wave interacts with the thermal phonon group in the vicinity of the perturbed part of the phonon spectrum caused by the impurity. The differences of time values between inelastic and elastic thermal phonons relaxations determined from the data on longitudinal and shear waves in pure and impurity garnet crystals are discussed

  14. Efficacy and safety of Erbium-doped Yttrium Aluminium Garnet fractional resurfacing laser for treatment of facial acne scars

    Directory of Open Access Journals (Sweden)

    Balakrishnan Nirmal

    2013-01-01

    Full Text Available Background: Treatment of acne scars with ablative fractional laser resurfacing has given good improvement. But, data on Indian skin are limited. A study comparing qualitative, quantitative, and subjective assessments is also lacking. Aim: Our aim was to assess the improvement of facial acne scars with Erbium-doped Yttrium Aluminium Garnet (Er:YAG 2940 nm fractional laser resurfacing and its adverse effects in 25 patients at a tertiary care teaching hospital. Methods: All 25 patients received four treatment sessions with Er:YAG fractional laser at 1-month interval. The laser parameters were kept constant for each of the four sittings in all patients. Qualitative and quantitative assessments were done using Goodman and Barron grading. Subjective assessment in percentage of improvement was also documented 1 month after each session. Photographs were taken before each treatment session and 1 month after the final session. Two unbiased dermatologists performed independent clinical assessments by comparing the photographs. The kappa statistics was used to monitor the agreement between the dermatologists and patients. Results: Most patients (96% showed atleast fair improvement. Rolling and superficial box scars showed higher significant improvement when compared with ice pick and deep box scars. Patient′s satisfaction of improvement was higher when compared to physician′s observations. No serious adverse effects were noted with exacerbation of acne lesions forming the majority. Conclusion: Ablative fractional photothermolysis is both effective and safe treatment for atrophic acne scars in Indian skin.Precise evaluation of acne scar treatment can be done by taking consistent digital photographs.

  15. Evidence of dilute ferromagnetism in rare-earth doped yttrium aluminium garnet

    Energy Technology Data Exchange (ETDEWEB)

    Farr, Warrick G.; Goryachev, Maxim; Le Floch, Jean-Michel; Tobar, Michael E. [ARC Centre of Excellence for Engineered Quantum Systems, University of Western Australia, 35 Stirling Highway, Crawley, Western Australia 6009 (Australia); Bushev, Pavel [Experimentalphysik, Universität des Saarlandes, D-66123 Saarbrücken (Germany)

    2015-09-21

    This work demonstrates strong coupling regime between an erbium ion spin ensemble and microwave hybrid cavity-whispering gallery modes in a yttrium aluminium garnet dielectric crystal. Coupling strengths of 220 MHz and mode quality factors in excess of 10{sup 6} are demonstrated. Moreover, the magnetic response of high-Q modes demonstrates behaviour which is unusual for paramagnetic systems. This behaviour includes hysteresis and memory effects. Such qualitative change of the system's magnetic field response is interpreted as a phase transition of rare earth ion impurities. This phenomenon is similar to the phenomenon of dilute ferromagnetism in semiconductors. The clear temperature dependence of the phenomenon is demonstrated.

  16. A randomized controlled trial of peeling and aspiration of Elschnig pearls and neodymium: yttrium-aluminium-garnet laser capsulotomy.

    Science.gov (United States)

    Bhargava, Rahul; Kumar, Prachi; Sharma, Shiv Kumar; Kaur, Avinash

    2015-01-01

    To compare surgical peeling and aspiration and neodymium yttrium garnet laser capsulotomy for pearl form of posterior capsule opacification (PCO). A prospective, randomized, double blind, study was done at Rotary Eye Hospital, Maranda, Palampur, India, Santosh Medical College Hospital, Ghaziabad, India and Laser Eye Clinic, Noida India. Consecutive patients with pearl form of PCO following surgery, phacoemulsification, manual small incision cataract surgery and conventional extracapsular cataract extraction (ECCE) for age related cataract, were randomized to have peeling and aspiration or neodymium yttrium garnet laser capsulotomy. Corrected distance visual acuity (CDVA), intra-operative and post-operative complications were compared. A total of 634 patients participated in the study, and 314 (49.5%) patients were randomized to surgical peeling and aspiration group and 320 (50.5%) to the Nd:YAG laser group. The mean pre-procedural logMAR CDVA in peeling and neodymium: yttrium-aluminium-garnet (Nd:YAG) laser group was 0.80±0.25 and 0.86±0.22, respectively. The mean final CDVA in peeling group (0.22±0.23) was comparable to Nd:YAG group (0.24±0.28; t test, P=0.240). There was a significant improvement in vision after both the procedures (Ppeeling group (262/83.4%) had a CDVA of 0.5 (20/63) or better at 9mo (Ppeeling group (25/7.7% vs 15/4.7%, respectively). On application of ANCOVA, there was less than 0.001% risk that PCO thickness and total laser energy had no effect on rate of complications in Nd:YAG laser group and less than 0.001 % risk that PCO thickness had no effect on complications in peeling group respectively. Sum of square analysis suggests that in the Nd:YAG laser group, thick PCO had a stronger impact on complications (Fischer test probability, Prpeeling group, thick PCO and preoperative vision had a stronger effect on complications than thin PCO, respectively (Fischer test probability, Prpeeling group. Retinal detachment was more common in patients

  17. A randomized controlled trial of peeling and aspiration of Elschnig pearls and neodymium:yttrium-aluminium-garnet laser capsulotomy

    Directory of Open Access Journals (Sweden)

    Rahul Bhargava

    2015-06-01

    Full Text Available AIM:To compare surgical peeling and aspiration and neodymium yttrium garnet laser capsulotomy for pearl form of posterior capsule opacification (PCO.METHODS:A prospective, randomized, double blind, study was done at Rotary Eye Hospital, Maranda, Palampur, India, Santosh Medical College Hospital, Ghaziabad, India and Laser Eye Clinic, Noida India. Consecutive patients with pearl form of PCO following surgery, phacoemulsification, manual small incision cataract surgery and conventional extracapsular cataract extraction (ECCE for age related cataract, were randomized to have peeling and aspiration or neodymium yttrium garnet laser capsulotomy. Corrected distance visual acuity (CDVA, intra-operative and post-operative complications were compared.RESULTS:A total of 634 patients participated in the study, and 314 (49.5% patients were randomized to surgical peeling and aspiration group and 320 (50.5% to the Nd:YAG laser group. The mean pre-procedural logMAR CDVA in peeling and neodymium:yttrium-aluminium-garnet (Nd:YAG laser group was 0.80±0.25 and 0.86±0.22, respectively. The mean final CDVA in peeling group (0.22±0.23 was comparable to Nd:YAG group (0.24±0.28; t test, P=0.240. There was a significant improvement in vision after both the procedures (P<0.001. A slightly higher percentage of patients in Nd:YAG laser group (283/88.3% than in peeling group (262/83.4% had a CDVA of 0.5 (20/63 or better at 9mo (P<0.001. On the contrary, patients having CDVA worse than 1.00 (20/200 was also significantly higher in Nd:YAG laser group as compared to peeling group (25/7.7% vs 15/4.7%, respectively. On application of ANCOVA, there was less than 0.001% risk that PCO thickness and total laser energy had no effect on rate of complications in Nd:YAG laser group and less than 0.001 % risk that PCO thickness had no effect on complications in peeling group respectively. Sum of square analysis suggests that in the Nd:YAG laser group, thick PCO had a stronger impact

  18. Surface melting technique of small diameter stainless steel pipe by means of yttrium aluminium garnet laser

    International Nuclear Information System (INIS)

    Katahira, Fujito; Hirano, Kenji; Tanaka, Yasuhiro; Yoshida, Kazuo; Kuribayashi, Munetaka; Umemoto, Tadahiro

    1994-01-01

    A new method of surface melting by using a high power yttrium aluminium garnet laser was developed. This method is applicable to a long distance and narrow space, because of the good accessibility of the laser beam through optical fibre.A desensitization of sensitized type 304 stainless steel pipe was demonstrated by using this technique. A melted layer of thickness approximately 200μm had a very finite solidification structure, which contained approximately 1.5% δ-ferrite. The average chemical composition of this layer was almost the same as that of type 304 stainless steel, and a band of 300μm thickness under the melted layer underwent solution heat treatment (SHT).As a result of such surface melting, the melted layer exhibited superior resistance to intergranular stress corrosion cracking (IGSCC). Since the SHT layer is highly resistant to IGSCC generally, it may be possible to improve the IGSCC resistance of base metal to a comparatively deep extent (500μm from the surface) by this technique. ((orig.))

  19. Surface melting technique of small diameter stainless steel pipe by means of yttrium aluminium garnet laser

    Energy Technology Data Exchange (ETDEWEB)

    Katahira, Fujito (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan)); Hirano, Kenji (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan)); Tanaka, Yasuhiro (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan)); Yoshida, Kazuo (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan)); Kuribayashi, Munetaka (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan)); Umemoto, Tadahiro (Ishikawajima-Harima Heavy Industries Co. Ltd., 1 Shin-Nakahara-Cho, Isogo-Ku, Yokohama 235 (Japan))

    1994-12-01

    A new method of surface melting by using a high power yttrium aluminium garnet laser was developed. This method is applicable to a long distance and narrow space, because of the good accessibility of the laser beam through optical fibre.A desensitization of sensitized type 304 stainless steel pipe was demonstrated by using this technique. A melted layer of thickness approximately 200[mu]m had a very finite solidification structure, which contained approximately 1.5% [delta]-ferrite. The average chemical composition of this layer was almost the same as that of type 304 stainless steel, and a band of 300[mu]m thickness under the melted layer underwent solution heat treatment (SHT).As a result of such surface melting, the melted layer exhibited superior resistance to intergranular stress corrosion cracking (IGSCC). Since the SHT layer is highly resistant to IGSCC generally, it may be possible to improve the IGSCC resistance of base metal to a comparatively deep extent (500[mu]m from the surface) by this technique. ((orig.))

  20. Evaluation of critical distances for energy transfer between Pr{sup 3+} and Ce{sup 3+} in yttrium aluminium garnet

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Peng; Wei, Xiantao; Yin, Min; Chen, Yonghu, E-mail: yhuchen@ustc.edu.cn [Key Laboratory of Strongly-Coupled Quantum Matter Physics, Chinese Academy of Sciences, School of Physical Sciences, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026 (China); Zhou, Shaoshuai [Key Laboratory of Strongly-Coupled Quantum Matter Physics, Chinese Academy of Sciences, School of Physical Sciences, University of Science and Technology of China, No. 96 Jinzhai Road, Hefei, Anhui 230026 (China); Department of Physics, Qufu Normal University, Qufu, Shandong 273165 (China)

    2016-09-07

    A series of Pr{sup 3+}/Ce{sup 3+} doped yttrium aluminium garnet (Y{sub 3}Al{sub 5}O{sub 12} or simply YAG) phosphors were synthesized to investigate the energy transfer between Pr{sup 3+} and Ce{sup 3+} for their potential application in a white light-emitting diode and quantum information storage and processing. The excitation and emission spectra of YAG:Pr{sup 3+}/Ce{sup 3+} were measured and analyzed, and it revealed that the reabsorption between Pr{sup 3+} and Ce{sup 3+} was so weak that it can be ignored, and the energy transfer from Pr{sup 3+} (5d) to Ce{sup 3+} (5d) and Ce{sup 3+} (5d) to Pr{sup 3+} ({sup 1}D{sub 2}) did occur. By analyzing the excitation and the emission spectra, the energy transfer from Pr{sup 3+} (5d) to Ce{sup 3+} (5d) and Ce{sup 3+} (5d) to Pr{sup 3+} ({sup 1}D{sub 2}) was examined in detail with an original strategy deduced from fluorescence dynamics and the Dexter energy transfer theory, and the critical distances of energy transfer were derived to be 7.9 Å and 4.0 Å for Pr{sup 3+} (5d) to Ce{sup 3+} (5d) and Ce{sup 3+} (5d) to Pr{sup 3+} ({sup 1}D{sub 2}), respectively. The energy transfer rates of the two processes of various concentrations were discussed and evaluated. Furthermore, for the purpose of sensing a single Pr{sup 3+} state with a Ce{sup 3+} ion, the optimal distance of Ce{sup 3+} from Pr{sup 3+} was evaluated as 5.60 Å, where the probability of success reaches its maximum value of 78.66%, and meanwhile the probabilities were evaluated for a series of Y{sup 3+} sites in a YAG lattice. These results will be of valuable reference for achievement of the optimal energy transfer efficiency in Pr{sup 3+}/Ce{sup 3+} doped YAG and other similar systems.

  1. Long-term result of out-patient neodymium-doped yttrium aluminium garnet laser photocoagulation surgery for patients with epistaxis.

    Science.gov (United States)

    Zhang, J; Qiu, R; Wei, C

    2016-01-01

    To evaluate the long-term efficacy of out-patient neodymium-doped yttrium aluminium garnet laser photocoagulation surgery for patients with epistaxis. A retrospective clinical study was conducted. A total of 217 consecutive patients who presented with acute or recurrent epistaxis received neodymium-doped yttrium aluminium garnet laser photocoagulation treatment in an out-patient setting. At three years, 94 per cent of acute epistaxis patients versus 88 per cent of recurrent epistaxis patients reported no bleeding. The outcome scores at 12 weeks and 3 years after treatment showed no significant differences between the 2 groups (p = 0.207 and p = 0.186). However, there was a significant difference in outcome scores at four weeks after treatment (p = 0.034). The median (and mean ± standard deviation) pain levels experienced during the laser operation (performed in an office setting) were 4.0 (3.75 ± 2.09) in the acute epistaxis group and 4.0 (3.83 ± 2.01) in the recurrent epistaxis group. Neither group had any complications. Neodymium-doped yttrium aluminium garnet laser photocoagulation is desirable in the treatment of both acute and recurrent epistaxis, and has long-lasting efficacy.

  2. Thermal effects from modified endodontic laser tips used in the apical third of root canals with erbium-doped yttrium aluminium garnet and erbium, chromium-doped yttrium scandium gallium garnet lasers.

    Science.gov (United States)

    George, Roy; Walsh, Laurence J

    2010-04-01

    To evaluate the temperature changes occurring on the apical third of root surfaces when erbium-doped yttrium aluminium garnet (Er:YAG) and erbium, chromium-doped yttrium scandium gallium garnet (Er,Cr:YSGG) laser energy was delivered with a tube etched, laterally emitting conical tip and a conventional bare design optical fiber tip. Thermal effects of root canal laser treatments on periodontal ligament cells and alveolar bone are of concern in terms of safety. A total of 64 single-rooted extracted teeth were prepared 1 mm short of the working length using rotary nickel-titanium Pro-Taper files to an apical size corresponding to a F5 Pro-Taper instrument. A thermocouple located 2 mm from the apex was used to record temperature changes arising from delivery of laser energy through laterally emitting conical tips or plain tips, using an Er:YAG or Er,Cr:YSGG laser. For the Er:YAG and Er,Cr:YSGG systems, conical fibers showed greater lateral emissions (452 + 69% and 443 + 64%) and corresponding lower forward emissions (48 + 5% and 49 + 5%) than conventional plain-fiber tips. All four combinations of laser system and fiber design elicited temperature increases less than 2.5 degrees C during lasing. The use of water irrigation attenuated completely the thermal effects of individual lasing cycles. Laterally emitting conical fiber tips can be used safely under defined conditions for intracanal irradiation without harmful thermal effects on the periodontal apparatus.

  3. Influence of neodymium-doping on structure and properties of yttrium aluminium garnet

    DEFF Research Database (Denmark)

    Zhang, X.D.; He, W.; Yue, Yuanzheng

    2013-01-01

    We study the impact of the Nd-doping on the grain formation, the crystal structure, and the fluorescence of the Yttrium Aluminum Garnet (YAG). The results show that Nd-doping leads to the YAG lattice expansion and distortion, and hence to an increase in defect concentration. This is attributed to...

  4. Interpretation of alumina/yttrium-aluminium garnet orientation relationships by geometric criteria

    International Nuclear Information System (INIS)

    Hay, R.S.; Matson, L.E.

    1991-01-01

    This paper reports on geometric criteria for low interface energy and interface structure were tested for the cubic-rhombohedral system YAG/alumina. Orientation relationships near (111)[110] a parallel (112)[110] y and facets on (111) a (112) y were observed in both sol-gel derived composites and directionally solidified eutectic composites. The Σ YAG = 12 near-CSL of 2[111], [110], [112] was inferred to be the preferred structural unit. Dislocations with b = 1/3[111] a and b = 1/2[110] a were observed and inferred to accommodate deviation from the structural unit, respectively. The [110] a, y direction met some of the criteria for an invariant line. Although the OR was explained by geometric criteria it would have been difficult to predict it with such criteria

  5. Alternative Treatment of Osteoma Using an Endoscopic Holmium-YAG Laser

    Directory of Open Access Journals (Sweden)

    Ba Leun Han

    2012-07-01

    Full Text Available Osteoma is one of the most common tumors of the cranial vault and the facial skeleton. For osteoma in the facial region, endoscopic resection is widely used to prevent surgical scarring. Tumors in a total of 14 patients were resected using an endoscopic holmium-doped yttrium aluminium garnet (Ho:YAG laser with a long flexible fiber. Aside from having the advantage of not leaving a scar due to the use of endoscopy, this procedure allowed resection at any position, was minimally invasive, and caused less postoperative pain. This method yielded excellent cosmetic results, so the endoscopic Ho:YAG laser is expected to emerge as a good treatment option for osteoma.

  6. Harmonic technology versus neodymium-doped yttrium aluminium garnet laser and electrocautery for lung metastasectomy: an experimental study.

    Science.gov (United States)

    Fiorelli, Alfonso; Accardo, Marina; Carelli, Emanuele; Del Prete, Assunta; Messina, Gaetana; Reginelli, Alfonso; Berritto, Daniela; Papale, Ferdinando; Armenia, Emilia; Chiodini, Paolo; Grassi, Roberto; Santini, Mario

    2016-07-01

    We compared the efficacy of non-anatomical lung resections with that of three other techniques: monopolar electrocautery; neodymium-doped yttrium aluminium garnet laser and harmonic technology. We hypothesized that the thermal damage with harmonic technology could be reduced because of the lower temperatures generated by harmonic technology compared with that of other devices. Initial studies were performed in 13 isolated pig lungs for each group. A 1.5-cm capsule was inserted within the lung to mimic a tumour and a total of 25 non-anatomical resections were performed with each device. The damage of the resected lung surface and of the tumour border were evaluated according to the colour (ranging from 0-pink colour to 4-black colour), histological (ranging from Score 0-no changes to Score 3-presence of necrotic tissue) and radiological (ranging from Score 0-isointense T2 signal at magnetic resonance imaging to Score 3-hyperintense T2 signal) criteria. A total of seven non-anatomical resections with harmonic technology were also performed in two live pigs to assess if ex vivo results could be reproducible in live pigs with particular attention to haemostatic and air-tightness properties. In the ex vivo lung, there was a statistical significant difference between depth of thermal damage (P laser (0.9 [0.6-0.9]) and harmonic (0.4 [0.3-0.5]) groups. Electrocautery had a higher depth of thermal damage compared with that of the laser (P = 0.01) and harmonic groups (P = 0.0005). The harmonic group had a less depth of thermal damage than that of the laser group (P = 0.01). Also, histological damages of tumour borders (P technology. Our experimental data support the resections performed with the use of harmonic technology. The lack of severe tissue alterations could favour healing of parenchyma, assure air tightness and preserve functional lung parenchyma. However, randomized controlled studies are needed in an in vivo model to corroborate our findings. © The Author 2016

  7. Thermal Properties of Transparent Yb-Doped YAG Ceramics at Elevated Temperatures

    Czech Academy of Sciences Publication Activity Database

    Hostaša, J.; Matějíček, Jiří; Nait-Ali, B.; Smith, D.S.; Pabst, W.; Esposito, L.

    2014-01-01

    Roč. 97, č. 8 (2014), s. 2602-2606 ISSN 0002-7820 Institutional support: RVO:61389021 Keywords : yttrium aluminium garnet * Yb:YAG * thermal diffusivity Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass Impact factor: 2.610, year: 2014 http://onlinelibrary.wiley.com/doi/10.1111/jace.13015/abstract

  8. Long-term remission of folliculitis decalvans after treatment with the long-pulsed Nd:YAG laser.

    Science.gov (United States)

    Meesters, Arne A; Van der Veen, J P Wietze; Wolkerstorfer, Albert

    2014-04-01

    Folliculitis decalvans (FD) is a rare inflammatory scalp disorder presenting with tufted folliculitis, follicular papules and pustules, progressing to cicatricial alopecia. Current treatments mainly consist of antibiotic and immunomodulatory therapies and are often disappointing. FD has previously shown to respond to treatment with neodymium:yttrium aluminium garnet (Nd:YAG) laser in one case. We present a case of recalcitrant FD, successfully treated with a long-pulsed Nd:YAG laser.

  9. Comparative evaluation of photoablative efficacy of erbium: yttrium-aluminium-garnet and diode laser for the treatment of gingival hyperpigmentation. A randomized split-mouth clinical trial.

    Science.gov (United States)

    Giannelli, Marco; Formigli, Lucia; Bani, Daniele

    2014-04-01

    The use of lasers in periodontology is a matter of debate, mainly because of the lack of consensual therapeutic protocols. In this randomized, split-mouth trial, the clinical efficacy of two different photoablative dental lasers, erbium:yttrium-aluminum-garnet (Er:YAG) and diode, for the treatment of gingival hyperpigmentation is compared. Twenty-one patients requiring treatment for mild-to-severe gingival hyperpigmentation were enrolled. Maxillary or mandibular left or right quadrants were randomly subjected to photoablative deepithelialization with either Er:YAG or diode laser. Masked clinical assessments of each laser quadrant were made at admission and days 7, 30, and 180 postoperatively by an independent observer. Histologic examination was performed before and soon after treatment and 6 months after irradiation. Patients also compiled a subjective evaluation questionnaire. Both diode and Er:YAG lasers gave excellent results in gingival hyperpigmentation. However, Er:YAG laser induced deeper gingival tissue injury than diode laser, as judged by bleeding at surgery, delayed healing, and histopathologic analysis. The use of diode laser showed additional advantages compared to Er:YAG in terms of less postoperative discomfort and pain. This study highlights the efficacy of diode laser for photoablative deepithelialization of hyperpigmented gingiva. It is suggested that this laser can represent an effective and safe therapeutic option for gingival photoablation.

  10. Comparison between 0.5% timolol maleate and 0.2% brimonidine tartrate in controlling increase in intraocular pressure after neodymium: yttrium-aluminium-garnet laser capsulotomy

    International Nuclear Information System (INIS)

    Tayyab, H.; Azhar, M.N.; Haider, M.A.; Jahangir, T.

    2013-01-01

    Objective: To compare the effectiveness of prophylactically given 0.5% Timolol maleate and 0.2% Brimonidine tartrate in controlling increase in intraocular pressure after neodymium (Nd) : yttrium aluminum garnet (YAG) laser capsulotomy. Study Design: Randomized controlled trial. Place and Duration of Study: This study was conducted at Ophthalmology Department, Jinnah Hospital, Lahore from 15-05-2009 to 14-05-2010 for a duration of 12 months. Material and Methods: In this study, 90 consecutive patients were referred from outpatient department for Nd: YAG laser capsulotomy. Hospital ethical committee's approval for this research proposal and the informed consent was taken. These patients were equally divided into two groups A and B, comprising of 45 patients in each group. Group A was control group which received 0.5% Timolol maleate. Group B was experimental group which received 0.2% Brimonidine tartrate. Intraocular pressure was measured using Goldmann tonometer before instilling these topical medications. These medications were administered topically 1 hour before the laser procedure. Intraocular pressure (IOP) was recorded 1 and 3 hours after laser capsulotomy. Results: In patients belonging to group A, 42 (93.3%) patients had effective control of IOP (raise of less than or equal to 5 mmHg from the baseline) after 3 hours of Nd:YAG laser capsulotomy whereas 28 (62.2%) patients had effective control of IOP after the same period of time in group-B with significant difference (p<0.001). Conclusion: Use of prophylactic topical antiglaucoma medications before doing Nd: YAG laser capsulotomy is a effective way to reduce post laser spike of intraocular pressure. Present study showed that the use of 0.5% timolol maleate was safe and more effective than 0.2% brimonidine tartrate when given 1 hour before laser capsulotomy. (author)

  11. Weldability of Advanced High Strength Steels using Ytterbium:Yttrium Aluminium Garnet high power laser for Tailor-Welded Blank applications

    Science.gov (United States)

    Sharma, Rajashekhar Shivaram

    Use of a high power Yb:YAG laser is investigated for joining advanced high strength steel materials for use in tailor-welded blank (TWB) applications. TWB's are materials of different chemistry, coating or thicknesses that are joined before metal forming and other operations such as trimming, assembly and painting are carried out. TWB is becoming an important design tool in the automotive industry for reducing weight, improving fuel economy and passenger safety, while reducing the overall costs for the customer. Three advanced high strength steels, TRIP780, DP980 and USIBOR, which have many unique properties that are conducive to achieving these objectives, along with mild steel, are used in this work. The objective of this work is to ensure that high quality welds can be obtained using Yb:YAG lasers which are also becoming popular for metal joining operations, since they produce high quality laser beams that suffer minimal distortion when transported via fiber optic cables. Various power levels and speeds for the laser beam were used during the investigation. Argon gas was consistently used for shielding purposes during the welding process. After the samples were welded, metallographic examination of the fusion and heat-affected zones using optical and scanning electron microscopes were carried out to determine the microstructures as well as weld defects. Optical and scanning electron microscopes were also used to examine the top of welds as well as fracture surfaces. Additionally, cross-weld microhardness evaluations, tensile tests using Instron tester, limited fatigue tests as well as formability evaluations using OSU plane strain evaluation were carried out. The examinations included a 2-factor full factorial design of experiments to determine the impact of coatings on the surface roughness on the top of the welds. Tensile strengths of DP980, TRIP780 and mild steel materials as well as DP980 welded to TRIP780 and mild steel in the rolling direction as well as

  12. Neodymium ion diffusion during sintering of Nd : YAG transparent ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Hollingsworth, Joel P; Kuntz, Joshua D; Soules, Thomas F [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA, 94550 (United States)

    2009-03-07

    Using an electron microprobe, we measured and characterized the Nd{sup 3+} ion diffusion across a boundary between Nd doped and undoped ceramic yttrium aluminium garnet (YAG) for different temperature ramps and hold times and temperatures. The results show significant Nd ion diffusion on the order of micrometres to tens of micrometres depending on the time and temperature of sintering. The data fit well a model including bulk diffusion, grain boundary diffusion and grain growth. Grain boundary diffusion dominates and grain growth limits grain boundary diffusion by reducing the total cross-sectional area of grain boundaries. (fast track communication)

  13. Nd-YAG laser treatment in a patient with complicated pilonidal cysts

    DEFF Research Database (Denmark)

    Lindholt, Christine S; Lindholt, Jes S.; Lindholt, Jan

    2009-01-01

    A 38-year-old woman with a recurrent suppurative pilonidal cyst was successfully treated causally with an Nd-YAG (neodymium-doped yttrium aluminium garnet) laser, and with no recurrence at 3-month follow-up. A similar success was observed for another 15 consecutively treated patients, including...... suppurative cases. The effect could be attributable to the ability of the YAG laser to operate at a wavelength of 1064 nm and to penetrate the skin to levels deeper than that of most other lasers before the energy is absorbed in melanin and oxyhaemoglobin. Consequently, the contents of the cyst can be reached...

  14. The use of molecular dynamics to simulate the temperature dependence of the calculated absorption spectrum for Nd3+ :YAG

    International Nuclear Information System (INIS)

    Klintenberg, M.; Thomas, J.O.; Edvardsson, S.

    1998-01-01

    Full text: We have previously shown that the use of molecular dynamics (MD) and the inclusion of configuration interaction (CI) effects are important when simulating polarized absorption spectra for rare-earth doped compounds. In this work, we focus on how well the MD approach can account for the temperature dependence of the calculated absorption spectrum for Nd 3+ :YAG (yttrium aluminium garnet), using the standard MD pair-potential of the Born-Mayer-Huggins form. All simulated spectra are compared to the corresponding experimental spectra. The results indicate that the simple pair-potential must be replaced by a many-body potential to describe the motion of the ions sufficiently accurately

  15. Clinical application of the Nd-YAG and Ho-YAG lasers in otolaryngology: head and neck surgery

    Science.gov (United States)

    Kukwa, Andrzej; Tulibacki, Marek P.; Dudziec, Katarzyna; Wojtowicz, Piotr

    1997-10-01

    The authors present their clinical experience regarding the possibilities of application of Nd:YAG and Ho:YAG lasers for the treatment of disorders in the area of the upper respiratory tract sinuses and ears. This technique makes it possible to perform a number of procedures in local anesthesia which considerably improves the economic effectiveness of the treatment. In case of the Nd:YAG laser they have also utilized the effect of deep coagulation of the soft tissues, whereas the Ho:YAG laser energy was applied for the surgery of bone tissue. The surgeries performed using laser beam enabled very good effect of treatment. They are competitive compared wit the methods used by traditional surgery.

  16. The possibility of clinical application of the solid state lasers: Nd:YAG, Ho:YAG, and Er:YAG in otolaryngology - head and neck surgery

    Science.gov (United States)

    Tomaszewska, M.; Kukwa, A.; Tulibacki, M.; Wójtowicz, P.; Olędzka, I.; Jeżewska, E.

    2007-02-01

    The purpose of this study was to summarize our experiences in clinical application of Nd:YAG, Ho:YAG and Er:YAG in otolaryngology- head and neck surgery. Choosing the laser type and parameters for the particular procedures was based on our previous research on tissue effects of those lasers. During the period of 1993-2006 we performed 3988 surgical procedures with the Nd:YAG laser. Over 87% of those were made for the nasal cavity pathologies as polyps, hyperplasia of inferior nasal turbinate, granulation tissue, postoperative adhesions, vascular malformations, under the local anesthesia conditions. In our experience Nd:YAG laser gives the possibility of good clinical control and low risk of side effects for disorders of high recurrence and frequent interventions necessity, as nasal polyps or respiratory papillomatosis. Nd:YAG assisted uvulopalatoplasty gives an interesting alternative for surgical procedures for snoring and slight/mild OSA-recognized patients. Due to its good hemostatic properties, it is a perfect tool for removal of the chemodectoma from meddle ear. During the period of 1995-2006 we performed 229 surgical procedures with the Ho:YAG laser, mostly for larynx pathologies (adhesion and scar tissue removal). In our experience Ho:YAG laser can serve as a precise laser knife for both soft and bony tissue. The ER:YAG laser still remain under clinical trial. Since 2001 year we performed 24 procedures of removing stone deposits from salivary glands. We believe it may become a promising method to cope with sialolithiasis which allows for glandule function preservation. All of the laser types mentioned above, can be easily coupled with endoscopes, what makes them available for all of the head and necklocalized disorders.

  17. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting.

    Science.gov (United States)

    Kim, Jin-Soo; Choi, Jung Yeol; Kwon, Ji-Won; Wee, Won Ryang; Han, Young Keun

    2018-01-01

    To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting. A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern). The best corrected visual acuity (BCVA), intraocular pressure (IOP), refractive error, endothelial cell count (ECC), anterior segment parameters, including anterior chamber depth (ACD) and anterior chamber angle (ACA) were measured before and 1mo after the laser posterior capsulotomy. In both groups, the BCVA improved significantly ( P <0.001 for the modified round pattern group, P =0.001 for the cruciate pattern group); the IOP and ECC did not significantly change. The ACD significantly decreased ( P <0.001 for both) and the ACA significantly increased ( P =0.001 for the modified round pattern group and P =0.034 for the cruciate group). The extent of changes in these parameters was not significantly different between the groups. Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  18. Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting

    Directory of Open Access Journals (Sweden)

    Jin-Soo Kim

    2018-02-01

    Full Text Available AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG laser posterior capsulotomy with vitreous strand cutting METHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO were included in this prospective randomized study and were randomly subjected to either cruciate pattern or round pattern Nd:YAG posterior capsulotomy with vitreous strand cutting (modified round pattern. The best corrected visual acuity (BCVA, intraocular pressure (IOP, refractive error, endothelial cell count (ECC, anterior segment parameters, including anterior chamber depth (ACD and anterior chamber angle (ACA were measured before and 1mo after the laser posterior capsulotomy. RESULTS: In both groups, the BCVA improved significantly (P<0.001 for the modified round pattern group, P=0.001 for the cruciate pattern group; the IOP and ECC did not significantly change. The ACD significantly decreased (P<0.001 for both and the ACA significantly increased (P=0.001 for the modified round pattern group and P=0.034 for the cruciate group. The extent of changes in these parameters was not significantly different between the groups. CONCLUSION: Modified round pattern Nd:YAG laser posterior capsulotomy is an effective and safe method for the treatment of PCO. This method significantly changes the ACD and ACA, but the change in refraction is not significant. Modified round pattern Nd:YAG laser posterior capsulotomy can be considered a good alternative procedure in patients with symptomatic PCO.

  19. Nd:YAG laser hyaloidotomy for valsalva pre-macular haemorrhage.

    LENUS (Irish Health Repository)

    Kirwan, R P

    2012-02-01

    AIM: To report a case of successful drainage of a large pre-macular haemorrhage using laser photo-disruption of the posterior hyaloid membrane. MATERIALS AND METHODS: A case report. RESULTS: A 47-year-old man presented acutely to our emergency department complaining of a 24-h history of sudden onset, painless and persistent loss of vision in his left eye. Immediately before noticing this loss of vision, he had been vomiting violently from excessive alcohol intake. The left visual acuity was counting fingers. Dilated fundoscopy of the left eye revealed a large pre-macular haemorrhage which was 14 disc diametres in size. Clotting investigations were normal. A diagnosis of valsalva retinopathy was made and the patient elected to receive a prompt neodymium-doped yttrium aluminium garnet (Nd:YAG) laser posterior hyaloidotomy as an outpatient. At 1 week follow-up, the haemorrhage had drained completely into the vitreous space revealing a healthy macula and the visual acuity had improved to 6\\/12 unaided. At 6-month follow-up the left visual acuity stabilised at 6\\/9 unaided. CONCLUSION: Nd:YAG laser posterior hyaloidotomy is a useful outpatient procedure for successful clearance of large pre-macular haemorrhages that offers patients rapid recovery of visual acuity and the avoidance of more invasive intraocular surgery.

  20. Ho:YAG laser: intervertebral disk cell interaction using three-dimensional cell culture system

    Science.gov (United States)

    Sato, Masato; Ishihara, Miya; Arai, Tsunenori; Asazuma, Takashi; Kikuchi, Toshiyuki; Kikuchi, Makoto; Fujikawa, Kyosuke

    2000-06-01

    The purpose of this study is to evaluate the influence on the intervertebral disc cells after laser irradiation using three- dimensional culture system and to clarify the optimum Ho:YAG laser irradiation condition on percutaneous laser disc decompression (PLDD) for lumbar disc herniation. Since the Ho:YAG laser ablation is characterized by water-vapor bubble dynamics, not only thermal effect but also acoustic effect on cell metabolism might occur in the intervertebral disc. We studied the disc cell reaction from the metabolic point of view to investigate photothermal and photoacoustic effects on three-dimensional cultured disc cell. Intervertebral discs were obtained from female 30 Japanese white rabbits weighing about 1 kg. A pulsed Ho:YAG laser (wavelength: 2.1 micrometer, pulse width: about 200 microseconds) was delivered through a 200 micrometer-core diameter single silica glass fiber. We used the Ho:YAG laser irradiation fluence ranging from 60 to approximately 800 J/cm2 at the fiber end. To investigate acoustic effect, the acoustic transducer constructed with polyvinylidene fluoride (PVdF) film and acoustic absorber was used to detect the stress wave. Thermocouple and thermography were used to investigate thermal effect. Concerning damage of plasma membrane and ability of matrix synthesis, thermal effect might mainly affect cell reaction in total energy of 54 J (closed to practically used condition), but in 27 J, acoustic effect might contribute to it. We found that total energy was key parameter among the optimum condition, so that temperature and/or stress wave may influence Ho:YAG laser-disc cell interactions.

  1. Evaluation of crystalline changes and resistance to demineralization of the surface of human dental enamel treated with Er:YAG laser and fluoride using x-ray diffraction analysis and Vickers microhardness

    Science.gov (United States)

    Behroozibakhsh, Marjan; Shahabi, Sima; Ghavami-Lahiji, Mehrsima; Sadeghian, Safura; Sadat Faal Nazari, Neda

    2018-06-01

    This study aimed to investigate the changes in crystalline structure and resistance to demineralization of human dental surface enamel treated with erbium-doped yttrium aluminium garnet laser (Er:YAG) laser and fluoride. The enamel surfaces were divided into four groups according to the treatment process including, (L): irradiated with Er:YAG; (F): treated with acidulated phosphate fluoride gel (LF): Pre-irradiated surfaces with Er:YAG subjected to acidulated phosphate fluoride gel and (FL): laser irradiation was performed on the fluoridated enamel surface. Before and after the treatment procedure, the samples were evaluated using X-ray diffraction, scanning electron microscope (SEM) and the Vickers microhardness test. The surface microhardness values also were measured after a pH-cycling regime and acid challenge. The a-axis of all lased groups was contracted after treatment procedure. Measurement of the area under the peaks showed the highest crysallinity in the FL group. The hardness values of all laser treated samples significantly reduced after treatment procedure compared to the F group (p  ⩽  0.001). The morphological observations showed remarkable changes on the lased enamel surfaces including cracks, craters and exposed prisms. These findings suggest, irradiation of the Er:YAG laser accompanying with fluoride application can induce some beneficial crystalline changes regarding the acid-resistance properties of enamel, however, the craters and cracks produced by laser irradiation can promote enamel demineralization and consequently the positive effects of the Er:YAG laser will be eliminated.

  2. Comparison of diode laser and Er:YAG lasers in the treatment of ankyloglossia.

    Science.gov (United States)

    Aras, Mutan Hamdi; Göregen, Mustafa; Güngörmüş, Metin; Akgül, Hayati Murat

    2010-04-01

    The purpose of this study was to compare the tolerance of lingual frenectomy with regard to a local anesthesia requirement and comparison of postsurgical discomfort experienced by patients operated on with both diode and erbium:yttrium-aluminium-garnet (Er:YAG) lasers. Ankyloglossia, commonly known as tongue-tie, is a congenital oral anomaly characterized by a short lingual frenulum. A short lingual frenulum may contribute to feeding, speech, and mechanical tongue problems. Sixteen referred patients with tongue mobility complaints were included in this study. A GaAlAs laser device with a continuous wavelength of 808 nm was used in the diode group. Frenulums were incised by applying 2 W of laser power. The Er:YAG laser device with a continuous wavelength of 2940 nm was used in the Er:YAG group. Frenulums were incised by applying 1 W of laser power. The acceptability of the lingual frenectomy without local anesthesia and the degree of the postsurgical discomfort were evaluated. Although the majority of patients (six) could be operated on without local anesthesia in the Er:YAG group, all patients could not be operated on without local anesthetic agent in the diode group. There were no differences between the two groups with regard to pain, chewing, and speaking on the first or seventh day after surgery, whereas patients had more pain in the Er:YAG group than in the diode group the first 3 h after surgery. The results indicate that only the Er:YAG laser can be used for lingual frenectomy without local anesthesia, and there was no difference between the two groups regarding the degree of the postsurgical discomfort except in the first 3 h. In conclusion, these results indicate that the Er:YAG laser is more advantageous than the diode laser in minor soft-tissue surgery because it can be performed without local anesthesia and with only topical anesthesia.

  3. An actively mode-locked Ho: YAG solid laser pumped by a Tm: YLF laser

    International Nuclear Information System (INIS)

    Yao, B Q; Cui, Z; Wang, J; Duan, X M; Dai, T Y; Du, Y Q; Yuan, J H; Liu, W

    2015-01-01

    A continuous wave mode-locked (CWML) Ho: YAG laser based on an acousto-optic modulator (AOM) pumped by a 1.9 μm Tm: YLF laser is demonstrated. This is the first time a report on an active CWML Ho: YAG laser has been published. A maximum output power of 1.04 W at 2097.25 nm in the CWML regime is obtained at a pump power of 13.2 W, corresponding to a slope efficiency of 13.3%. The mode-locked pulse repetition frequency is 82.76 MHz and the single pulse energy is 12.57 nJ. The mode-locked pulse width is 102 ps measured through a no-background second harmonic autocorrelation with KTP as the nonlinear crystal. Furthermore, the M 2 factor is calculated to be 1.146. (letter)

  4. Numerical Simulation of the Micro-explosion during Ho:YAG laser lithotripsy

    International Nuclear Information System (INIS)

    Yao Yucheng; Huang Chuyun; Xu Guowang; Yan Xudong; Wang Yanlin

    2011-01-01

    The micro-explosion during Ho:YAG laser lithotripsy may cause calculus fragmentation and migration. It plays an important role to the surgery. A numerical simulation of the micro-explosion during Ho:YAG laser lithotripsy has been developed. The explosion problem in water environment was solved by the Euler algorithm and the piecewise parabolic method (PPM) was selected in the calculation. This simulation investigated the explosion dynamics evolution in the lithotripsy area. The pressure and intensity of the calculus surface were calculated for different laser pulse energy and different distance between calculus and fiber tip. The calculation results indicate that the micro-explosion's properties are determined by the pulse energy, pulse duration and the water distance. Though Short pulse duration and large pulse energy cause high ablation efficiency, it mains more calculus retropulsion at the same time. The ideal surgery results need property laser parameters.

  5. High Power Q-Switched Dual-End-Pumped Ho:YAG Laser

    Energy Technology Data Exchange (ETDEWEB)

    Xiao-Ming, Duan; Ying-Jie, Shen; Tong-Yu, Dai; Bao-Quan, Yao; Wang Yue-Zhu, E-mail: xmduan@hit.edu.cn [National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150001 (China)

    2012-09-15

    We report the high power acousto-optically Q-switched operation of a dual-end-pumped Ho:YAG laser at room temperature. For the Q-swithched mode, a maximum pulse energy of 2.4 mJ and a minimum pulse width of 23 ns at the repetition rate of 10 kHz are achieved, resulting in a peak power of 104.3 kW. The beam quality factor of M{sup 2} {approx} 1.5, which is demonstrated by a knife-edge method. In addition, the Ho:YAG laser is employed as a pumping source of ZGP optical parametric oscillator, and its total average output power is 13.2 W at 3.9 {mu}m and 4.4 {mu}m with a slope efficiency of 68.4%.

  6. Multiple minimally invasive Erbium:YAG laser mini-peels for skin rejuvenation: An objective assessment

    Science.gov (United States)

    El-Domyati, Moetaz; El-Ammawi, Tarek S.; Medhat, Walid; Moawad, Osama; Mahoney, Mỹ G.; Uitto, Jouni

    2012-01-01

    Summary Background As the demand for minimally invasive rejuvenation is increasing, micro-peel resurfacing using Erbium:Yttrium Aluminium Garnet (Er:YAG ) laser 2940 nm has been reported for the treatment of photoaged skin without ablation of the epidermis. However, little is known about the efficacy and underlying histologic changes associated with this type of treatment. Aims The purpose of this study is to evaluate the clinical effect and objectively quantify the histological changes in response to multiple sessions of Er:YAG laser 2940 nm mini-peels. Patients and methods Six female volunteers of Fitzpatrick skin type III-IV and Glogau’s class I-III wrinkles were subjected to six microresurfacing peels at 2-week intervals using Er:YAG 2940 nm laser at sub-ablative fluences of 2 - 3 J/cm2 to treat periorbital rhytides. Quantitative evaluation of collagen types I, III and VII, newly synthesized collagen, total elastin and tropoelastin was performed by histochemistry and immunohistochemistry coupled with computerized morphometric analysis at base line, end of treatment, and three months post treatment. Results Compared to the base line, evaluation of volunteers revealed obvious clinical improvement in response to Er:YAG mini-peels. Collagen types I, III, and VII, as well as newly synthesized collagen, together with tropoelastin showed a statistically significant increase in response to treatment, while the mean level of total elastin was significantly decreased in response to treatment. However, this was followed by regression of improvement at 3 months post treatment, but was still better than baseline. Conclusions The present study revealed that multiple Er:YAG mini-peels is a promising treatment option for photoaging as it reverses the signs of photoaged skin with little downtime and side effects. However, to maintain the short term improvement achieved after treatment, continued Er:YAG 2940 nm laser mini-peels is required. PMID:22672276

  7. Comparison of a long-pulse Nd:YAG laser and a combined 585/1,064-nm laser for the treatment of acne scars: a randomized split-face clinical study.

    Science.gov (United States)

    Min, Seong U K; Choi, Yu Sung; Lee, Dong Hun; Yoon, Mi Young; Suh, Dae Hun

    2009-11-01

    Nonablative laser is gaining popularity because of the low risk of complications, especially in patients with darker skin. To compare the efficacy and safety of a long-pulse neodymium-doped yttrium aluminium garnet (Nd:YAG) laser and a combined 585/1,064-nm laser for the treatment of acne scars. Nineteen patients with mild to moderate atrophic acne scars received four long-pulse Nd:YAG laser or combined 585/1,064-nm laser treatment sessions at fortnightly intervals. Treatments were administered randomly in a split-face manner. Acne scars showed mild to moderate improvement, with significant Echelle d'évaluation clinique des cicatrices d'acné (ECCA) score reductions, after both treatments. Although intermodality differences were not significant, combined 585/1,064-nm laser was more effective for deep boxcar scars. In patients with combined 585/1,064-nm laser-treated sides that improved more than long-pulse Nd:YAG laser-treated sides, ECCA scores were significantly lower for combined 585/1,064-nm laser treatment. Histologic evaluations revealed significantly greater collagen deposition, although there was no significant difference between the two modalities. Patient satisfaction scores concurred with physicians' evaluations. Both lasers ameliorated acne scarring with minimal downtime. In light of this finding, optimal outcomes might be achieved when laser treatment types are chosen after considering individual scar type and response.

  8. Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance.

    Science.gov (United States)

    Bader, Markus J; Pongratz, Thomas; Khoder, Wael; Stief, Christian G; Herrmann, Thomas; Nagele, Udo; Sroka, Ronald

    2015-04-01

    In vitro investigations of Ho:YAG laser-induced stone fragmentation were performed to identify potential impacts of different pulse durations on stone fragmentation characteristics. A Ho:YAG laser system (Swiss LaserClast, EMS S.A., Nyon, Switzerland) with selectable long or short pulse mode was tested with regard to its fragmentation and laser hardware compatibility properties. The pulse duration is depending on the specific laser parameters. Fragmentation tests (hand-held, hands-free, single-pulse-induced crater) on artificial BEGO stones were performed under reproducible experimental conditions (fibre sizes: 365 and 200 µm; laser settings: 10 W through combinations of 0.5, 1, 2 J/pulse and 20, 10, 5 Hz, respectively). Differences in fragmentation rates between the two pulse duration regimes were detected with statistical significance for defined settings. Hand-held and motivated Ho:YAG laser-assisted fragmentation of BEGO stones showed no significant difference between short pulse mode and long pulse mode, neither in fragmentation rates nor in number of fragments and fragment sizes. Similarly, the results of the hands-free fragmentation tests (with and without anti-repulsion device) showed no statistical differences between long pulse and short pulse modes. The study showed that fragmentation rates for long and short pulse durations at identical power settings remain at a comparable level. Longer holmium laser pulse duration reduces stone pushback. Therefore, longer laser pulses may result in better clinical outcome of laser lithotripsy and more convenient handling during clinical use without compromising fragmentation effectiveness.

  9. Two-wave generator of subnanosecond radiation pulses on an yttrium-aluminium garnet

    International Nuclear Information System (INIS)

    Babikov, Yu.I.; Ir, K.S.; Mironov, V.E.

    1988-01-01

    Great attention is paid to the electron accelerator based on the mechanism of electron accelerator in the field of plasma wave, excited by laser radiation. The laser system master generator based on serial LTIPC-8 laser is described. The system is intended for investigating the plasma excitation processes initiated by two-frequency laser radiation beats. Pulse duration is ≤1 ns at 3-4 pulse train. Radiation on 1.0615 and 1.0641 μm wave length is generated. 5 refs.; 3 figs

  10. Yttrium aluminium garnet under pressure: Structural, elastic, and vibrational properties from ab initio studies

    International Nuclear Information System (INIS)

    Monteseguro, V.; Rodríguez-Hernández, P.; Muñoz, A.

    2015-01-01

    The structural, elastic, and vibrational properties of yttrium aluminum garnet Y 3 Al 5 O 12 are studied under high pressure by ab initio calculations in the framework of the density functional theory. The calculated ground state properties are in good agreement with the available experimental data. Pressure dependences of bond length and bulk moduli of the constituent polyhedra are reported. The evolution of the elastic constants and the major elastic properties, Young and shear modulus, Poisson's ratios, and Zener anisotropy ratio, are described. The mechanical stability is analyzed, on the light of “Born generalized stability criteria,” showing that the garnet is mechanically unstable above 116 GPa. Symmetries, frequencies, and pressure coefficients of the Raman-active modes are discussed on the basis of the calculated total and partial phonon density of states, which reflect the dynamical contribution of each atom. The relations between the phonon modes of Y 3 Al 5 O 12 and the internal and external molecular modes of the different polyhedra are discussed. Infrared-active modes, as well as the silent modes, and their pressure dependence are also investigated. No dynamical instabilities were found below 116 GPa

  11. Dependence of calculus retropulsion dynamics on fiber size and radiant exposure during Ho:YAG lithotripsy.

    Science.gov (United States)

    Lee, Ho; Ryan, Robert T; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Teichman, Joel M H; Welch, A J

    2004-08-01

    During pulsed laser lithotripsy, the calculus is subject to a strong recoil momentum which moves the calculus away from laser delivery and prolongs the operation. This study was designed to quantify the recoil momentum during Ho:YAG laser lithotripsy. The correlation among crater shape, debris trajectory, laser-induced bubble and recoil momentum was investigated. Calculus phantoms made from plaster of Paris were ablated with free running Ho:YAG lasers. The dynamics of recoil action of a calculus phantom was monitored by a high-speed video camera and the laser ablation craters were examined with Optical Coherent Tomography (OCT). Higher radiant exposure resulted in larger ablation volume (mass) which increased the recoil momentum. Smaller fibers produced narrow craters with a steep contoured geometry and decreased recoil momentum compared to larger fibers. In the presence of water, recoil motion of the phantom deviated from that of phantom in air. Under certain conditions, we observed the phantom rocking towards the fiber after the laser pulse. The shape of the crater is one of the major contributing factors to the diminished recoil momentum of smaller fibers. The re-entrance flow of water induced by the bubble collapse is considered to be the cause of the rocking of the phantom.

  12. Microbiological effects and recolonization patterns after adjunctive subgingival debridement with Er:YAG laser.

    Science.gov (United States)

    Sanz-Sánchez, Ignacio; Ortiz-Vigón, Alberto; Herrera, David; Sanz, Mariano

    2016-07-01

    The objective of this study was to assess the microbiological effects and recolonization patterns after non-surgical periodontal treatment protocol based on the adjunctive use of erbium-doped yttrium aluminium garnet (Er:YAG) laser. Patients diagnosed with chronic periodontitis were randomly assigned to two different treatment protocols: test, full-mouth subgingival ultrasonic instrumentation followed by Er-YAG laser application 1 week later to sites with initial probing pocket depth ≥4.5 mm; and control, full-mouth ultrasonic subgingival instrumentation within 1 week. Clinical (at sampled sites) and microbiological (culture-based) parameters were recorded at baseline and 3 and 12 months. Microbiological variables included total counts, frequency of detection, proportions and counts of target species. Results from 19 test and 21 control patients were compared. Minor changes were observed for total colony-forming units, with no differences between groups. For the frequency of detection, a limited and similar impact in both groups was observed for the most prevalent (over 80 %) periodontal pathogens (Porphyromonas gingivalis, Prevotella intermedia, Fusobacterium nucleatum). For proportions, reductions in P. gingivalis occurred at 3 months, both in the test and control groups (from 16.3 to 10 % and 16 to 14.8 %, respectively), although these differences were not statistically significant. At 12 months, the test group showed a statistically significant greater reduction in probing depth for the sampled sites. The adjunctive use of Er:YAG laser when compared with conventional ultrasonic debridement did not provide a microbiological added benefit. Even though some clinical benefits with the adjunctive laser application were identified when comparing both treatment protocols, there were no differences in microbiological outcomes or in the bacterial recolonization patterns.

  13. Photoluminescence characterization of porous YAG: Yb{sup 3+}–Er{sup 3+} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Desirena, H., E-mail: hagdes@cio.mx [Centro de Investigaciones en Óptica, A. P. 1-948, León 37150, Guanajuato (Mexico); Diaz-Torres, L.A. [Centro de Investigaciones en Óptica, A. P. 1-948, León 37150, Guanajuato (Mexico); Rodríguez, R.A. [Centro Universitario de Los Lagos, Universidad de Guadalajara, Lagos de Moreno, Jalisco (Mexico); Meza, O. [Instituto de Física, Benemérita Universidad Autónoma de Puebla, Apartado Postal J-48, Centro Historico 72570, Puebla (Mexico); Salas, P. [Centro de Física Aplicada y Tecnología Avanzada, Universidad Nacional Autónoma de México, Apartado Postal 1-1010, Querétaro 76000, Querétaro México (Mexico); Angeles-Chávez, C. [Instituto Mexicano del Petróleo, Ciudad México, D.F. 07730, México (Mexico); Tobar, E.H.; Castañeda-Contreras, J. [Centro Universitario de Los Lagos, Universidad de Guadalajara, Lagos de Moreno, Jalisco (Mexico); De la Rosa, E., E-mail: elder@cio.mx [Centro de Investigaciones en Óptica, A. P. 1-948, León 37150, Guanajuato (Mexico)

    2014-09-15

    Yb{sup 3+}/Er{sup 3+} codoped yttrium aluminium garnet (YAG) porous nanocrystals were prepared by glycolate method assisted with poly-vinyl alcohol (PVA) and urea. The typical cubic structure for YAG was confirmed from XRD with crystallite average size of ∼40 nm, calculated from Scherrer formula and corroborated by TEM. Strong green and red upconversion emissions are observed readily with the naked eyes, and the color coordinates were obtained from emission spectra. A theoretical model to calculate CIE coordinate as a function of donor (Yb{sup 3+}) and acceptors (Er{sup 3+}) concentration is proposed. The eye-safe near infrared emitted signal and fluorescence lifetime were also measured and results show lifetime as large as 8.5 ms. The maximum energy transfer efficiency from Yb{sup 3+} to Er{sup 3+} was 72% for 20 mol% of Yb{sub 2}O{sub 3}. The proposed mechanisms for signal emitted are explained in terms of direct and energy back transfer processes, and cross relaxation. - Highlights: • Strong upconversion emission were observed in YAG:Er{sup 3+}–Yb{sup 3+} samples. • Color emission can be tuned from green to red by choosing properly the Yb{sup 3+} concentration. • The experimental colour coordinates match very well with the proposed theoretical model. • Cross relaxation and energy back transfer are mainly responsible for the red emission. • Fluorescence lifetime of {sup 4}I{sub 13/2} level increase with the Yb{sup 3+} concentration.

  14. Tissue effects of Ho:YAG laser with varying fluences and pulse widths

    Science.gov (United States)

    Vari, Sandor G.; van der Veen, Maurits J.; Pergadia, Vani R.; Shi, Wei-Qiang; Duffy, J. T.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1994-02-01

    We investigated the effect of varying fluence and pulse width on the ablation rate and consequent thermal damage of the Ho:YAG (2.130 micrometers ) laser. The rate of ablation on fresh bovine knee joint tissues, fibrous cartilage, hyaline cartilage, and bone in saline was determined after varying the fluence (160 - 640 J/cm2) and pulse width (150, 250, 450 microsecond(s) ec, FWHM) at a repetition rate of 2 Hz. A 400/440 micrometers fiber was used. The ablation rate increased linearly with the fluence. In fibrocartilage, different pulse durations generated significant changes in the ablation rates, but showed minor effects on hyaline cartilage and bone. The heat of ablation for all three tissue types decreased after lengthening the pulse.

  15. 36 W Q-switched Ho:YAG laser at 2097 nm pumped by a Tm fiber laser: evaluation of different Ho3+ doping concentrations

    Science.gov (United States)

    Antipov, O. L.; Eranov, I. D.; Kositsyn, R. I.

    2017-01-01

    A laser oscillator based on Ho:YAG crystal pumped by a Tm fiber laser with an acousto-optical Q-switch was optimized for maximum output power and pulse-to-pulse stability. Stable operation at 2097 nm in Q-switched mode is demonstrated, with pulse repetition rates from 10 to 30 kHz, and output power of 36 W (at 55 W of pump power at 1908 nm) in the good quality beam. The influence of Ho ion up-conversion and thermal lensing on the oscillation efficiency is discussed.

  16. Laser lithotripsy with the Ho:YAG laser: fragmentation process revealed by time-resolved imaging

    Science.gov (United States)

    Schmidlin, Franz R.; Beghuin, Didier; Delacretaz, Guy P.; Venzi, Giordano; Jichlinski, Patrice; Rink, Klaus; Leisinger, Hans-Juerg; Graber, Peter

    1998-07-01

    Improvements of endoscopic techniques have renewed the interest of urologists in laser lithotripsy in recent years. Laser energy can be easily transmitted through flexible fibers thereby enabling different surgical procedures such as cutting, coagulating and lithotripsy. The Ho:YAG laser offers multiple medical applications in Urology, among them stone fragmentation. However, the present knowledge of its fragmentation mechanism is incomplete. The objective was therefore to analyze the fragmentation process and to discuss the clinical implications related to the underlying fragmentation mechanism. The stone fragmentation process during Ho:YAG laser lithotripsy was observed by time resolved flash video imaging. Possible acoustic transient occurrence was simultaneously monitored with a PVDF-needle hydrophone. Fragmentation was performed on artificial and cystine kidney stones in water. We observed that though the fragmentation process is accompanied with the formation of a cavitation bubble, cavitation has only a minimal effect on stone fragmentation. Fragment ejection is mainly due to direct laser stone heating leading to vaporization of organic stone constituents and interstitial water. The minimal effect of the cavitation bubble is confirmed by acoustic transients measurements, which reveal weak pressure transients. Stone fragmentation with the Holmium laser is the result of vaporization of interstitial (stone) water and organic stone constituents. It is not due to the acoustic effects of a cavitation bubble or plasma formation. The fragmentation process is strongly related with heat production thereby harboring the risk of undesired thermal damage. Therefore, a solid comprehension of the fragmentation process is needed when using the different clinically available laser types of lithotripsy.

  17. Studi Analisis Serbuk dengan Teknik Krim Silikon Menggunakan Plasma Tekanan Tinggi yang Diinduksi oleh Laser Nd: YAG

    Directory of Open Access Journals (Sweden)

    Syahrun Nur Madjid

    2012-12-01

    Full Text Available Laser-Induced Breakdown Spectroscopy (LIBS is a technique that used for quantitative elemental analysis of various samples in different forms. In this technique, a laser light is focused on the surface of sample yielding a plasma just above the sample surface that used for analytical source. Nowadays, rapid powder analysis in tiny amount (mg has been carried out using plasma induced by high power laser of  Nd:YAG (Neodymium-doped Yttrium Aluminium Garnet at atmospheric pressure. However, powder analysis using high power laser is still difficult to be carried out  due to blow of powder when irradiated laser beam focused on a powder sample. In general, the powder must be transformed into pellet form prior to analysis. Pellet sample requires a lot of powder and it takes time for preparation. In this study, we developed a technique of powder sample with its size about  30 µm (± 5 mg that mixed with silicon grease (± 5 mg that act as a binder. The mixed sample then thinly painted on the metal plate as sub-target. The study showed that by employing sillicon grease technique, a semiquantitative analysis of several elements contain in coal, rock, and  water  can be conducted. Meanwhile heavy metal in soils is still not able to detect. This results showed that sillicon grease technique using  Nd:YAG laser can be applied for rapid semi-quantitative analysis of powder samples available only in tiny amounts. Keywords: high pressured plasma, Nd:YAG laser, powder analysis, silicon grease technique

  18. A highly efficient Ho:YAG laser in-band pumped by a linewidth-narrowed Tm:YLF laser

    International Nuclear Information System (INIS)

    Duan, X M; Yang, C H; Yao, B Q; Wang, Y Z; Zhang, W S

    2013-01-01

    A highly efficient Tm:YLF-Ho:YAG laser system is presented in this paper. To obtain the narrow linewidth 1908 nm laser output, a volume Bragg grating combined with a Fabry–Perot (FP) etalon were used as wavelength selection devices. The maximum output power of 28.7 W was obtained with a slope efficiency of 42.3% in the Tm:YLF laser. An output wavelength of 1908.1 nm and FWHM linewidth of 60 pm were achieved at the maximum output level. Using this Tm:YLF laser as the pump source, high efficiency continuous wave and Q-switched operation of a Ho:YAG laser was demonstrated. Operating at continuous wave mode, up to 73.3% slope efficiency and 67.4% optical conversion efficiency were obtained in the Ho:YAG laser, corresponding to a diode-to-Ho optical conversion efficiency of 23.7%. For the Q-switched mode, when the incident Tm power was 27.3 W, the maximum single pulse energy of 3.4 mJ, pulse width of 15 ns and peak power of 229.3 kW were achieved at the pulse repetition rate of 5 kHz. The maximum average power of 18.3 W, pulse width of 18 ns and peak power of 103.6 kW were obtained at the pulse repetition rate of 10 kHz. (paper)

  19. Comparison of Enamel Morphologic Characteristics after Conditioning with Various Combinations of Acid Etchant and Er:YAG Laser in Bonding and Rebonding Procedures: A SEM Analysis

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Ahmad Akhoundi

    2017-10-01

    Full Text Available Objectives: Many studies have evaluated re-etched enamel by using scanning electron microscopy (SEM; however, there is no evidence regarding the use of Erbium-doped yttrium aluminium garnet (Er:YAG laser at primary and secondary bonding instead of acid etching with regards to enamel surface changes. The purpose of the present study was to determine that whether or not the methods of primary and secondary enamel preparation affect enamel characteristics after rebonding, by using SEM analysis.Materials and Methods: Twelve freshly extracted premolars were divided into 4 groups. The samples in each group were conditioned by acid etchant or Er:YAG laser at primary conditioning, according to the instructions. Afterwards, they were bonded with orthodontic brackets. After debonding, the samples were prepared for second conditioning. Also, two samples were conditioned only once with acid etchant or laser, to compare enamel morphology changes with those after re-etching. Finally, buccal enamel surfaces were evaluated using SEM.Results: Enamel etching patterns were observed in the samples which had been acid-conditioned at first or at both conditionings. The samples irradiated by Er:YAG laser showed amorphous and irregular surfaces, with no signs of typical etching patterns. A large deep gap was seen in one of the samples irradiated with laser at primary and secondary conditionings, which might have penetrated the underling layers of enamel and dentin.Conclusions: Enamel surface preparation with Er:YAG laser produces irregular and indistinct morphologic changes, completely different from those produced after acid etching at both conditioning and reconditioning. Therefore, it is recommended to use this laser with caution to avoid permanent enamel damage.

  20. In-process monitoring and adaptive control for gap in micro butt welding with pulsed YAG laser

    International Nuclear Information System (INIS)

    Kawahito, Yousuke; Kito, Masayuki; Katayama, Seiji

    2007-01-01

    A gap is one of the most important issues to be solved in laser welding of a micro butt joint, because the gap results in welding defects such as underfilling or a non-bonded joint. In-process monitoring and adaptive control has been expected as one of the useful procedures for the stable production of sound laser welds without defects. The objective of this research is to evaluate the availability of in-process monitoring and adaptive control in micro butt welding of pure titanium rods with a pulsed neodymium : yttrium aluminium garnet (Nd : YAG) laser beam of a 150 μm spot diameter. It was revealed that a 45 μm narrow gap was detected by the remarkable jump in a reflected light intensity due to the formation of the molten pool which could bridge the gap. Heat radiation signal levels increased in proportion to the sizes of molten pools or penetration depths for the respective laser powers. As for adaptive control, the laser peak power was controlled on the basis of the reflected light or the heat radiation signals to stably produce a sound deeply penetrated weld reduced underfilling. In the case of a 100 μm gap, the underfilling was greatly reduced by half smaller than those made with a conventional rectangular pulse shape in seam welding as well as spot welding with a pulsed Nd : YAG laser beam. Consequently, the adaptive control of the laser peak power on the basis of in-process monitoring could reduce the harmful effects due to a gap in micro butt laser welding with a pulsed laser beam

  1. A comparative investigation of bone surface after cutting with mechanical tools and Er:YAG laser.

    Science.gov (United States)

    Baek, Kyung-Won; Deibel, Waldemar; Marinov, Dilyan; Griessen, Mathias; Dard, Michel; Bruno, Alfredo; Zeilhofer, Hans-Florian; Cattin, Philippe; Juergens, Philipp

    2015-07-01

    Despite of the long history of medical application, laser ablation of bone tissue became successful only recently. Laser bone cutting is proven to have higher accuracy and to increase bone healing compared to conventional mechanical bone cutting. But the reason of subsequent better healing is not biologically explained yet. In this study we present our experience with an integrated miniaturized laser system mounted on a surgical lightweight robotic arm. An Erbium-doped Yttrium Aluminium Garnet (Er:YAG) laser and a piezoelectric (PZE) osteotome were used for comparison. In six grown up female Göttingen minipigs, comparative surgical interventions were done on the edentulous mandibular ridge. Our laser system was used to create different shapes of bone defects on the left side of the mandible. On the contralateral side, similar bone defects were created by PZE osteotome. Small bone samples were harvested to compare the immediate post-operative cut surface. The analysis of the cut surface of the laser osteotomy and conventional mechanical osteotomy revealed an essential difference. The scanning electron microscopy (SEM) analysis showed biologically open cut surfaces from the laser osteotomy. The samples from PZE osteotomy showed a flattened tissue structure over the cut surface, resembling the "smear layer" from tooth preparation. We concluded that our new finding with the mechanical osteotomy suggests a biological explanation to the expected difference in subsequent bone healing. Our hypothesis is that the difference of surface characteristic yields to different bleeding pattern and subsequently results in different bone healing. The analyses of bone healing will support our hypothesis. © 2015 Wiley Periodicals, Inc.

  2. Acute and chronic response of articular cartilage to Ho:YAG laser irradiation

    Science.gov (United States)

    Trauner, Kenneth B.; Nishioka, Norman S.; Flotte, Thomas J.; Patel, Dinesh K.

    1992-06-01

    A Ho:YAG laser system operating at a wavelength of 2.1 microns has recently been introduced for use in arthroscopic surgery. The acceptability of this new tool will be determined not only by its ability to resect tissue, but also by its long term effects on articular surfaces. In order to investigate these issues further, we performed two studies to evaluate the acute and chronic effects of the laser on cartilaginous tissue. We evaluated the acute, in vitro effects of 2.1 micron laser irradiation on articular and fibrocartilage. This included the measurement of ablation efficiency, ablation threshold and thermal damage in both meniscus and articular cartilage. To document the chronic effects on articular cartilage in vivo, we next performed a ten week healing study. Eight sheep weighing 30 - 40 kg underwent bilateral arthrotomy procedures. Multiple full thickness and partial thickness defects were created. Animals were sacrificed at 0, 2, 4, and 10 weeks. The healing study demonstrated: (1) no healing of full or partial thickness defects at 10 weeks with hyaline cartilage; (2) fibrocartilaginous granulation tissue filling full thickness defects at two and four weeks, but no longer evident at ten weeks; (3) chondrocyte necrosis extending to greater than 900 microns distal to ablation craters at four weeks with no evidence of repair at later dates; and (4) chondrocyte hyperplasia at the borders of the damage zone at two weeks but no longer evident at later sacrifice dates.

  3. Comparative in vitro study of tissue welding using a 808 nm diode laser and a Ho:YAG laser.

    Science.gov (United States)

    Ott, B; Züger, B J; Erni, D; Banic, A; Schaffner, T; Weber, H P; Frenz, M

    2001-01-01

    In vitro porcine arteries and veins have been welded end-to-end using either a 808 nm diode laser combined with an indocyanine green enhanced albumin solder, or with a continuous-wave (cw) Ho:YAG laser without biological solder. The vascular stumps were approached to each other over a coronary dilatation catheter in order to obtain a precise alignment and good coaptation. Standard histology revealed for both welding techniques lateral tissue damage between 2 and 3 mm caused by laser-induced heat. Good solder attachment to the tissue was observed by the use of a scanning electron microscope. The vessels soldered with the 808 nm diode laser using albumin solder showed considerably higher tensile strength (1 N compared to 0.3 N) than vessels welded exclusively by Ho:YAG laser radiation. In contrast, leaking pressure (350 +/- 200 mmHg) and bursting pressure (457 +/- 200 mmHg) were found to be independent of the welding technique used. This study demonstrates that fast (total welding time about 2-5 min), stable and tight microvascular anastomosis can be achieved with the use of a dye-enhanced albumin laser soldering technique and an ancillary coronary dilatation catheter.

  4. A Q-switched Ho:YAG laser with double anti-misalignment corner cubes pumped by a diode-pumped Tm:YLF laser

    Science.gov (United States)

    Wang, Y. P.; Dai, T. Y.; Wu, J.; Ju, Y. L.; Yao, B. Q.

    2018-06-01

    We report the acousto-optically Q-switched Ho:YAG laser with double anti-misalignment corner cubes pumped by a diode-pumped Tm:YLF laser. In the continuous-wave operation of Ho:YAG laser, the maximum s-polarized output power of 3.2 W at 2090.3 nm was obtained under the absorbed pump power of 12.9 W by rotating the fast axis of quarter-wave plate to change the output transmission of laser cavity. The corresponding optical-to-optical conversion efficiency was 24.8% and the slope efficiency was 55.7%. When one of the corner cubes was rotated to 11.8° around vertical direction or 6.7° around horizontal direction, the laser could still operate stably. For the Q-switched operation, the pulse energy of Ho:YAG laser was 9.9 mJ with a pulse width of 53 ns at the repetition rate of 100 Hz, resulting in a peak power of 186.8 kW. The beam quality factor M2 of Ho:YAG laser was 1.3.

  5. Efficient Long Wave IR Laser from Ho:YAG 2 {mu}m Pumped ZnGeP{sub 2} Optical Parametric Oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Li-Gang,; Bao-Quan, Yao; Xiao-Ming, Duan; Guo-Li, Zhu; Yue-Zhu, Wang; You-Lun, Ju [National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150001 (China)

    2010-01-15

    An efficient high power long wave infrared laser based on ZnGeP{sub 2} optical parametric oscillator pumped by a 2.09 {mu}m Tm:YLF/Ho:YAG laser at 10KHz pulse repetition rate is reported. The pump to idler conversion efficiency is 8% at 15.6 W Ho pump power level and a quantum efficiency of 31 % when the 1'idler wavelength is tuned at 8.08 {mu}m. The wavelength tuning range from 8-9.1 {mu}m is also achieved by rotating the ZGP crystal. (fundamental areas of phenomenology(including applications))

  6. Experimental application of pulsed Ho:YAG laser-induced liquid jet as a novel rigid neuroendoscopic dissection device.

    Science.gov (United States)

    Ohki, Tomohiro; Nakagawa, Atsuhiro; Hirano, Takayuki; Hashimoto, Tokitada; Menezes, Viren; Jokura, Hidefumi; Uenohara, Hiroshi; Sato, Yasuhiko; Saito, Tsutomu; Shirane, Reizo; Tominaga, Teiji; Takayama, Kazuyoshi

    2004-01-01

    Although water jet technology has been considered as a feasible neuroendoscopic dissection methodology because of its ability to perform selective tissue dissection without thermal damage, problems associated with continuous use of water and the ensuing fountain-effect-with catapulting of the tissue-could make water jets unsuitable for endoscopic use, in terms of safety and ease of handling. Therefore, the authors experimented with minimization of water usage during the application of a pulsed holmium:yttrium-aluminum-garnet (Ho:YAG) laser-induced liquid jet (LILJ), while assuring the dissection quality and the controllability of a conventional water jet dissection device. We have developed the LILJ generator for use as a rigid neuroendoscope, discerned its mechanical behavior, and evaluated its dissection ability using the cadaveric rabbit ventricular wall. The LILJ generator is incorporated into the tip of a stainless steel tube (length: 22 cm; internal diameter: 1.0 mm; external diameter: 1.4 mm), so that the device can be inserted into a commercial, rigid neuroendoscope. Briefly, the LILJ is generated by irradiating an internally supplied water column within the stainless steel tube using the pulsed Ho:YAG laser (wave length: 2.1 microm, pulse duration time: 350 microseconds) and is then ejected through the metal nozzle (internal diameter: 100 microm). The Ho:YAG laser pulse energy is conveyed through optical quartz fiber (core diameter: 400 microm), while cold water (5 degrees C) is internally supplied at a rate of 40 ml/hour. The relationship between laser energy (range: 40-433 mJ/pulse), standoff distance (defined as the distance between the tip of the optical fiber and the nozzle end; range: 10-30 mm), and the velocity, shape, pressure, and average volume of the ejected jet were analyzed by means of high-speed camera, PVDF needle hydrophone, and digital scale. The quality of the dissection plane, the preservation of blood vessels, and the penetration depth

  7. Growth and characterization of Yb:Ho:YAG single crystal fiber

    Science.gov (United States)

    Yang, Yilun; Ye, Linhua; Bao, Renjie; Li, Shanming; Zhang, Peixiong; Xu, Min; Hang, Yin

    2018-06-01

    High quality Yb and Ho co-doped Y3Al5O12 single crystal fibers have been successfully grown by the laser heated pedestal growth method of up to 124 mm in length and 450 μm in diameter for the first time. The results of inductively coupled plasma-atomic emission spectrometry analysis, X-ray diffraction and Raman spectroscopy reveal that the lattice structure and doping concentrations of the SCF are the same as that of the bulk. Scanning electron microscopy microphotographs shows that the fibers only have minor diameter fluctuations within 0.5%.

  8. Ho:YAG laser in reshaping tracheal cartilage: a pilot investigation using ex vivo porcine and rabbit cartilage

    Science.gov (United States)

    Lam, Anthony; Protsenko, Dmitry E.; Carbone, Nicholas; Li, Chao; Jackson, Ryan; Wong, Brian J.

    2004-07-01

    Stenotic, collapsed, and flow-restricted tracheal airways may result from blunt trauma, chronic infection, and the prolonged endotracheal intubation. This pilot investigation characterizes the degree of shape change produced by Ho:YAG laser (λ=2.12 μm) irradiation of rabbit and pig trachea tissue as a function of laser dosimetry and application protocol. Force displacement curves were generated using fresh lagomorph and porcine tracheal cartilage rings secured in a modified single beam cantilever geometry. These specimens were then irradiated for varying amounts of time and power with the objective of straightening these curved specimens. The degree of shape change was documented photographically. Force and surface temperature were monitored. Confocal microscopy was then used in combination a vital staine ("live-dead assay") to determine the level of viability of straightened cartilage for selected exposure time-power pairs. Laser Cartilage Reshaping of the trachea may provide a new method to treat severe tracheal injuries without the need for classic open surgical techniques. This pilot investigation is the first step toward demonstrating the feasibility of this technique. Long-term, the design of stents combined with laser irradiation may provide a means to alter tracheal shape.

  9. Numerical Response Surfaces of Volume of Ablation and Retropulsion Amplitude by Settings of Ho:YAG Laser Lithotripter

    Directory of Open Access Journals (Sweden)

    Jian J. Zhang

    2018-01-01

    Full Text Available Objectives. Although laser lithotripsy is now the preferred treatment option for urolithiasis due to shorter operation time and a better stone-free rate, the optimal laser settings for URS (ureteroscopic lithotripsy for less operation time remain unclear. The aim of this study was to look for quantitative responses of calculus ablation and retropulsion by performing operator-independent experiments to determine the best fit versus the pulse energy, pulse width, and the number of pulses. Methods. A lab-built Ho:YAG laser was used as the laser pulse source, with a pulse energy from 0.2 J up to 3.0 J and a pulse width of 150 μs up to 1000 μs. The retropulsion was monitored using a high-speed camera, and the laser-induced craters were evaluated with a 3-D digital microscope. The best fit to the experimental data is done by a design of experiment software. Results. The numerical formulas for the response surfaces of ablation speed and retropulsion amplitude are generated. Conclusions. The longer the pulse, the less the ablation or retropulsion, while the longer pulse makes the ablation decrease faster than the retropulsion. The best quadratic fit of the response surface for the volume of ablation varied nonlinearly with pulse duration and pulse number.

  10. Numerical Response Surfaces of Volume of Ablation and Retropulsion Amplitude by Settings of Ho:YAG Laser Lithotripter

    Science.gov (United States)

    Rutherford, Jonathan; Solomon, Metasebya; Cheng, Brian; Xuan, Jason R.; Gong, Jason; Yu, Honggang; Xia, Michael L. D.; Yang, Xirong; Hasenberg, Thomas; Curran, Sean

    2018-01-01

    Objectives Although laser lithotripsy is now the preferred treatment option for urolithiasis due to shorter operation time and a better stone-free rate, the optimal laser settings for URS (ureteroscopic lithotripsy) for less operation time remain unclear. The aim of this study was to look for quantitative responses of calculus ablation and retropulsion by performing operator-independent experiments to determine the best fit versus the pulse energy, pulse width, and the number of pulses. Methods A lab-built Ho:YAG laser was used as the laser pulse source, with a pulse energy from 0.2 J up to 3.0 J and a pulse width of 150 μs up to 1000 μs. The retropulsion was monitored using a high-speed camera, and the laser-induced craters were evaluated with a 3-D digital microscope. The best fit to the experimental data is done by a design of experiment software. Results The numerical formulas for the response surfaces of ablation speed and retropulsion amplitude are generated. Conclusions The longer the pulse, the less the ablation or retropulsion, while the longer pulse makes the ablation decrease faster than the retropulsion. The best quadratic fit of the response surface for the volume of ablation varied nonlinearly with pulse duration and pulse number. PMID:29707187

  11. Análises morfométrica e morfológica das alterações cutâneas após uso do laser Nd-YAG em tecidos palpebrais humanos Cutaneous changes morphometrical and histological analysis after the use of laser Nd-YAG in human eyelid tissue

    Directory of Open Access Journals (Sweden)

    Lúcia de Noronha

    2004-06-01

    Full Text Available O uso do laser neodymium-yttrium-aluminium-garnet (Nd-YAG como instrumento auxiliar para o rejuvenescimento propiciou um refinamento da técnica tradicional. Tal procedimento mostra resultados satisfatórios com relação ao aprimoramento técnico e à recuperação pós-operatória. OBJETIVO: Evidenciar as alterações histológicas e morfométricas encontradas na pálpebra de humanos após aplicação do laser Nd-YAG e comparar com a pele normal. MATERIAL E MÉTODO: Nove pacientes do sexo feminino foram submetidas à aplicação do laser Nd-YAG em região palpebral direita. A pálpebra esquerda correspondeu à área controle, livre de qualquer tipo de procedimento. Foram realizadas várias aplicações do laser Nd-YAG, sendo que, no último dia, foi realizada biópsia palpebral bilateralmente. Os critérios morfométricos avaliados foram: medida da espessura da epiderme, da área subepidérmica livre de lesão, da zona de degeneração do colágeno e da espessura total da derme. RESULTADOS: Nas áreas submetidas à aplicação do laser Nd-YAG, a espessura média da epiderme foi de 33,53 micrômetros (µm e a da pele normal foi de 29,61µm (p = 0,1099. A média da medida da área subepidérmica livre de lesão, no lado direito, foi de 40,93µm, e de 36,27µm (p = 0,1373 no esquerdo. A espessura da região de degeneração do colágeno na pálpebra que recebeu tratamento com laser teve média de 293,54µm, enquanto que na pálpebra normal ela foi de 292,22µm (p = 0,4835. No lado onde se aplicou o laser Nd-YAG, a espessura total da derme teve uma média de 681,48µm e, no lado livre de procedimento, 664,14µm (p = 0,3492. DISCUSSÃO E CONCLUSÕES: Apesar da diferença clínica observada após tratamento de lesões de envelhecimento em pálpebra de humanos com o uso do laser Nd-YAG, nota-se que não houve diferença histológica ou morfométrica após tal procedimento.The use of laser Neodymium-Yttrium-Aluminium-Garnet (Nd-YAG as an auxiliary

  12. Calculus migration characterization during Ho:YAG laser lithotripsy by high-speed camera using suspended pendulum method.

    Science.gov (United States)

    Zhang, Jian James; Rajabhandharaks, Danop; Xuan, Jason Rongwei; Chia, Ray W J; Hasenberg, Thomas

    2017-07-01

    Calculus migration is a common problem during ureteroscopic laser lithotripsy procedure to treat urolithiasis. A conventional experimental method to characterize calculus migration utilized a hosting container (e.g., a "V" grove or a test tube). These methods, however, demonstrated large variation and poor detectability, possibly attributed to the friction between the calculus and the container on which the calculus was situated. In this study, calculus migration was investigated using a pendulum model suspended underwater to eliminate the aforementioned friction. A high-speed camera was used to study the movement of the calculus which covered zero order (displacement), first order (speed), and second order (acceleration). A commercialized, pulsed Ho:YAG laser at 2.1 μm, a 365-μm core diameter fiber, and a calculus phantom (Plaster of Paris, 10 × 10 × 10 mm 3 ) was utilized to mimic laser lithotripsy procedure. The phantom was hung on a stainless steel bar and irradiated by the laser at 0.5, 1.0, and 1.5 J energy per pulse at 10 Hz for 1 s (i.e., 5, 10, and 15 W). Movement of the phantom was recorded by a high-speed camera with a frame rate of 10,000 FPS. The video data files are analyzed by MATLAB program by processing each image frame and obtaining position data of the calculus. With a sample size of 10, the maximum displacement was 1.25 ± 0.10, 3.01 ± 0.52, and 4.37 ± 0.58 mm for 0.5, 1, and 1.5 J energy per pulse, respectively. Using the same laser power, the conventional method showed <0.5 mm total displacement. When reducing the phantom size to 5 × 5 × 5 mm 3 (one eighth in volume), the displacement was very inconsistent. The results suggested that using the pendulum model to eliminate the friction improved sensitivity and repeatability of the experiment. A detailed investigation on calculus movement and other causes of experimental variation will be conducted as a future study.

  13. Efeito do Hólmio YAG laser (Ho: YAG sobre o tendão patelar de ratos após 12 e 24 semanas de seguimento The effects of Holmium YAG laser (Ho:YAG on the patellar tendon of rats after 12 and 24 weeks of follow up

    Directory of Open Access Journals (Sweden)

    Waldo Lino Júnior

    2005-01-01

    Full Text Available Os autores estudaram os efeitos do laser Hólmio:Ítrio-Alumínio-Granada (Ho: YAG sobre as dimensões do tendão (comprimento e largura proximal e distal e sobre a celularidade e arranjo das fibras de colágeno em 20 ratos adultos, machos, brancos (Ratus Novergicus da varidade Wistar. Os animais foram divididos em dois grupos de acordo com o tempo de seguimento (12 e 24 semanas e de acordo com a forma de aplicação do laser (contínua e em dois pontos. Utilizou-se aparelho de laser de Hólmio (pulsátil, estado sólido, com ondas de 2,1 microns, com potência de 40 watts, ponteira OmniTip de 30º . Após o sacrifício, foram comparadas por meio de testes não paramétricos (considerando p = 0,05 as medidas de comprimento e da largura (proximal e distal dos tendões do lado operado e do lado não operado. A medida do comprimento do lado operado foi significativamente maior nos dois grupos de seguimento, quando comparado com o lado não operado, porém, não houve diferença significativa dessas medidas em função do tipo de aplicação do laser. Do mesmo modo, a medida da largura, tanto na região proximal quanto distal, foram significativamente maiores no lado operado nos dois grupos de seguimento, sem apresentar diferença significativa em função do tipo de aplicação. Quando se compararam as medidas nos dois grupos de seguimento, o comprimento e a largura distal tenderam a ser maiores após 24 semanas, enquanto que a largura, na região proximal, foi significativamente maior nesse grupo. Quanto à avaliação microscópica subjetiva, tanto nos cortes longitudinais como transversais, pôde-se verificar aumento do número de fibroblastos, principalmente no grupo de 12 semanas. A concentração média de fibroblastos nos tendões com 24 semanas de seguimento foi considerada como intermediário entre o grupo de 12 semanas e os tendões não operados. Na região entre os fascículos, o tecido conjuntivo era exuberante no grupo com 12 semanas

  14. Moderate high power 1 to 20μs and kHz Ho:YAG thin disk laser pulses for laser lithotripsy

    Science.gov (United States)

    Renz, Günther

    2015-02-01

    An acousto-optically or self-oscillation pulsed thin disk Ho:YAG laser system at 2.1 μm with an average power in the 10 W range will be presented for laser lithotripsy. In the case of cw operation the thin disk Ho:YAG is either pumped with InP diode stacks or with a thulium fiber laser which leads to a laser output power of 20 W at an optical-to-optical efficiency of 30%. For the gain switched mode of operation a modulated Tm-fiber laser is used to produce self-oscillation pulses. A favored pulse lengths for uric acid stone ablation is known to be at a few μs pulse duration which can be delivered by the thin disk laser technology. In the state of the art laser lithotripter, stone material is typically ablated with 250 to 750 μs pulses at 5 to 10 Hz and with pulse energies up to a few Joule. The ablation mechanism is performed in this case by vaporization into stone dust and fragmentation. With the thin disk laser technology, 1 to 20 μs-laser pulses with a repetition rate of a few kHz and with pulse energies in the mJ-range are available. The ablation mechanism is in this case due to a local heating of the stone material with a decomposition of the crystalline structure into calcium carbonate powder which can be handled by the human body. As a joint process to this thermal effect, imploding water vapor bubbles between the fiber end and the stone material produce sporadic shock waves which help clear out the stone dust and biological material.

  15. Ovlivnění dentinového povrchu pulzním Nd:YAG laserem

    Czech Academy of Sciences Publication Activity Database

    Zapletalová, Z.; Peřina ml., Jan; Chmelíčková, Hana; Novotný, R.; Stranyánek, Martin

    2005-01-01

    Roč. 105, č. 6 (2005), s. 159-164 ISSN 1213-0613 R&D Projects: GA AV ČR(CZ) IBS1010353 Institutional research plan: CEZ:AV0Z10100522 Keywords : dentine hypersensitivity * dentinal tubules * Nd:YAG laser * melting of dentine surface Subject RIV: BH - Optics, Masers, Lasers

  16. Successful treatment of laser induced hypopigmentation with narrowband ultraviolet B targeted phototherapy

    Directory of Open Access Journals (Sweden)

    Venkataram Mysore

    2013-01-01

    Full Text Available Q-switched 1064 nm neodymium-doped yttrium aluminium garnet (Qs 1064 nm Nd: YAG laser plays an important role in the treatment of pigmentary skin disorders, including tattoos. Although it has high efficacy and safety, adverse effect like hypopigmentation may occur causing anxiety to patients. We present a case report of Qs 1064 nm Nd: YAG laser induced hypopigmentation which was successfully treated with ultraviolet B targeted phototherapy, with rapid and satisfactory re-pigmentation.

  17. The use of lasers for periodontal debridement: marketing tool or proven therapy?

    Science.gov (United States)

    Chanthaboury, Rachel; Irinakis, Tassos

    2005-10-01

    The use of lasers in dentistry has recently received much attention, in both clinical practice and research; their unique properties produce favourable clinical results in some cases and encourage patient acceptance. Various types of lasers have been investigated as an adjunct to periodontal therapy; these include carbon dioxide (CO2), diode, neodymium:yttrium-aluminium-garnet (Nd:YAG) and erbium:yttrium-aluminium-garnet (Er:YAG) lasers.However, adverse results have been associated with each type, including thermal damage to root surfaces, increases in pulpal temperature and the production of toxic by-products. The Er:YAG laser has produced the most promising results, as it can ablate effectively with minimal adverse effects. More research is needed to determine the ideal settings and methods for using the laser safely and effectively in clinical practice.

  18. Evaluation of Long Pulsed-ND: Yag Laser in The Treatment of Onychomycosis

    International Nuclear Information System (INIS)

    Ahmad, E.M.A.

    2013-01-01

    topical or systemic treatment (Donald et al., 2002). The choice of therapy is influenced by the presentation and severity of the disease, other medications that the patient is taking, physician and patient preference, and cost (Gupta et al., 2003). A novel non-invasive approach for treatment of onychomycosis is the application of laser energy to the nail plate targeting the fungal cells themselves. By using a laser with a specific wavelength of laser light energy, the fungus could be directly targeted in the nail and heated to the point it is killed, but without burning the surrounding tissue and with leaving the skin and nail intact (Kozarev and Vizintin, 2010). The Nd-Yag (neodymium-doped yttrium aluminium garnet; Nd: Y 3 Al 5 O 12 ) laser is such a device with a wavelength 1064 nm that will pass through the nail plate and into the nail bed resulting in superheating of the fungal material. Exposure of fungi to high temperatures inhibits their growth as well as causing cell damage and death (Hashimoto and Blumenthal, 1978). Several other types of lasers are introduced for the treatment of onychomycosis including diode laser (Landsman et al., 2010) femtosecond infrared titanium sapphire laser (Manevitch et al., 2010). A novel 0.65-millisecond pulsed Nd:YAG is also introduced for the treatment of onychomycosis (Mozena and Haverstock, 2010).

  19. A Q-switched Ho:YAG laser assisted nanosecond time-resolved T-jump transient mid-IR absorbance spectroscopy with high sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Li, Deyong; Li, Yunliang; Li, Hao; Weng, Yuxiang, E-mail: yxweng@iphy.ac.cn [Key Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Wu, Xianyou [Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 230031 (China); Yu, Qingxu [School of Physics and Optoelectronic Technology, Dalian University of Technology, No. 2, Linggong Road, Dalian 116023 (China)

    2015-05-15

    Knowledge of dynamical structure of protein is an important clue to understand its biological function in vivo. Temperature-jump (T-jump) time-resolved transient mid-IR absorbance spectroscopy is a powerful tool in elucidating the protein dynamical structures and the folding/unfolding kinetics of proteins in solution. A home-built setup of T-jump time-resolved transient mid-IR absorbance spectroscopy with high sensitivity is developed, which is composed of a Q-switched Cr, Tm, Ho:YAG laser with an output wavelength at 2.09 μm as the T-jump heating source, and a continuous working CO laser tunable from 1580 to 1980 cm{sup −1} as the IR probe. The results demonstrate that this system has a sensitivity of 1 × 10{sup −4} ΔOD for a single wavelength detection, and 2 × 10{sup −4} ΔOD for spectral detection in amide I′ region, as well as a temporal resolution of 20 ns. Moreover, the data quality coming from the CO laser is comparable to the one using the commercial quantum cascade laser.

  20. Exporting advanced service tech to Europe

    International Nuclear Information System (INIS)

    Naredo, F.P.

    1991-01-01

    The concept of Westinghouse's European Service Center (ESC), located at Nivelles, Belgium, to bring advanced services and maintenance technologies to European customers is described. Laser-welded sleeving to repair degraded steam generator tubes employing pulsed Neodymium Yttrium Aluminium Garnet (Nd:YAG) laser, which Westinghouse has developed for 22mm tubing is mentioned. U-bend heat treatment (UBHT) technology was also brought to Europe by Westinghouse

  1. Radiation defects in some oxide compounds

    International Nuclear Information System (INIS)

    Kaczmarek, S.M.

    1999-01-01

    Yttrium aluminium garnets, yttrium aluminium perovskite, strontium and barium lanthanum and gadolinium gallates, lithium niobate and tantalate as-grown crystals and doped by diffusion with rare-earth (Nd, Dy, Er, Tm, Ho, Pr, Ce, Eu) and ions of the first transition series (Mn, Cr, Cu, Fe) were investigated optically and using electron spin resonance method before and after gamma, electron and proton irradiation. (author)

  2. Cathodoluminescence properties of yttrium aluminum garnet doped with Eu2+ and Eu3+ ions

    International Nuclear Information System (INIS)

    Trofimov, A. N.; Petrova, M. A.; Zamoryanskaya, M. V.

    2007-01-01

    Yttrium aluminium garnet (YAG) doped with Eu 2+ and Eu 3+ ions is very interesting as a phosphor for conversion of light-emitting diode light for white light sources. The europium ion occupies the structural position of yttrium in yttrium aluminium garnet and has valence state Eu 3+ . Our sample was doped with Zr 4+ , which is why some of the europium ions had valence state Eu 2+ . As a rule, luminescence of Eu 3+ ions is observed in the orange and red range of spectrum. The luminescence of Eu 2+ in yttrium aluminum garnet is characterized by an intensive broad band with maximum of intensity at about 560 nm (green color). In this work, we studied the intensity and decay time dependences on europium concentration, and the influence of excitation power density on the cathodoluminescence of the sample. The most interesting result is the change of visible cathodoluminescence color in dependence on the density of the exciting power

  3. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    Science.gov (United States)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and

  4. Ultrafine luminescent structures through nanoparticle self-assembly

    International Nuclear Information System (INIS)

    Prabhakaran, K; Goetzinger, S; Shafi, K V P M; Mazzei, A; Schietinger, S; Benson, O

    2006-01-01

    We report the fabrication of ultrafine structures consisting of regular arrays of nanoemitters through the self-assembly of luminescent nanoparticles on a silicon wafer. Nanoparticles of yttrium aluminium garnet (YAG) doped with Eu 3+ ions were synthesized by a sonochemical technique. These particles, suspended in ethanol, are introduced onto a pre-patterned silicon wafer, covered with a thin oxide layer. On annealing the sample in an ultrahigh-vacuum chamber, the nanoparticles self-assemble along the pattern. We demonstrate this 'chemical lithography' by assembling the nanoparticles along a variety of patterns. We believe that such self-organized nanopatterning of functional structures is important for the realization of nanodevices

  5. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    Science.gov (United States)

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption

  6. Holmium:YAG laser stapedotomy: preliminary evaluation

    Science.gov (United States)

    Stubig, Ingrid M.; Reder, Paul A.; Facer, G. W.; Rylander, Henry G.; Welch, Ashley J.

    1993-07-01

    This study investigated the use of a pulsed Holmium:YAG ((lambda) equals 2.09 micrometers ) laser- fiber microsurgical system for laser stapedotomy. This system ablates human stapes bones effectively with minimal thermal damage. The study was designed to determine the effectiveness of the Ho:YAG laser (Schwartz Electro Optics, Inc., Orlando, FL) for stapedotomy and to evaluate temperature changes within the cochlea during the ablation process. Human cadaveric temporal bones were obtained and the stapes portion of the ossicular chain was removed. A 200 micrometers diameter low OH quartz fiber was used to irradiate these stapes bones in an air environment. The laser was pulsed at 2 Hz, 250 microsecond(s) ec pulse width and an irradiance range of 100 - 240 J/cm2 was used to ablate holes in the stapes footplate. The resultant stapedotomies created had smooth 300 micrometers diameter holes with a minimum of circumferential charring. Animal studies in-vivo were carried out in chinchillas to determine the caloric spread within the cochlea. A 0.075 mm Type T thermocouple was placed in the round window. Average temperature change during irradiation of the stapes footplate recorded in the round window was 3.6 degree(s)C. The data suggest that stapedotomy using the Ho:YAG laser can result in a controlled ablation of the stapes footplate with minimal thermal damage to the surrounding stapes. Optical coupling using fiberoptic silica fibers is an ideal method for delivering laser energy to the stapes during stapedotomy.

  7. Efficient Ho:YLF laser pumped by a Tm:fiber laser

    CSIR Research Space (South Africa)

    Koen, W

    2013-10-01

    Full Text Available A thulium fiber laser pumped Ho:YLF laser delivering 45.1 W in a near diffraction limited beam when pumped with 84.7 W is demonstrated. The optical-to-optical efficiency of 53 % compares favorably with similar Ho:YAG lasers....

  8. Laser micromachining of indium tin oxide films on polymer substrates by laser-induced delamination

    International Nuclear Information System (INIS)

    Willis, David A; Dreier, Adam L

    2009-01-01

    A Q-switched neodymium : yttrium-aluminium-garnet (Nd : YAG) laser was used to ablate indium tin oxide (ITO) thin films from polyethylene terephthalate substrates. Film damage and partial removal with no evidence of a melt zone was observed above 1.7 J cm -2 . Above the film removal threshold (3.3 J cm -2 ) the entire film thickness was removed without substrate damage, suggesting that ablation was a result of delamination of the film in the solid phase. Measurements of ablated fragment velocities near the ablation threshold were consistent with calculations of velocities caused by stress-induced delamination of the ITO film, except for a high velocity component at higher fluences. Nanosecond time-resolved shadowgraph photography revealed that the high velocity component was a shock wave induced by the rapid compression of ambient air when the film delaminated.

  9. Do We Really Need to Wear Proper Eye Protection When Using Holmium:YAG Laser During Endourologic Procedures? Results from an Ex Vivo Animal Model on Pig Eyes.

    Science.gov (United States)

    Villa, Luca; Cloutier, Jonathan; Compérat, Eva; Kronemberg, Peter; Charlotte, Frederic; Berthe, Laurent; Rouchausse, Yann; Salonia, Andrea; Montorsi, Francesco; Traxer, Olivier

    2016-03-01

    We sought to evaluate the effect of holmium:yttrium-aluminum-garnet (Ho:YAG) laser exposure on ex vivo pig eyes and to test the protective action of different glasses in preventing eye lesions in case of accident. We pointed the tip of a Ho:YAG laser fiber from different distances (0, 3, 5, 8, 10, and 20 cm, respectively) toward the center of the pupil of the pig eye. The Ho:YAG laser was activated for 1 or 5 seconds at three different settings (0.5 J-20 Hz, 1 J-10 Hz, and 2 J-10 Hz, respectively). The experiment was repeated using laser safety glasses and eyeglasses. A total of 78 pig eyes were used. The effects of the Ho:YAG laser on pig eyes were assessed by histopathology. Comparable laser emission experiments were performed on thermal paper at different distances using different pulse energies. Ho:YAG laser-induced corneal lesions were observed in unprotected eyes, ranging from superficial burning lesions to full-thickness necrotic areas, and were directly related to pulse energy and time of exposure and inversely related to the distance from the eye. When the laser was placed 5 cm or more, no corneal damage was observed regardless of the laser setting and the time of exposure. Similar distance/energy level relationships were observed on thermal paper. No damage was observed to the lens or the retina in any of the Ho-YAG laser-treated eyes or in any of the eyes protected by laser safety and eyeglasses. Ho:YAG lasers can cause damage when set to high energy, but only to the cornea, from close distances (0-5 cm) and in the absence of eye protection. Eyeglasses are equally effective in preventing laser damage as laser safety glasses.

  10. Ho:YLF pumped HBr laser

    CSIR Research Space (South Africa)

    Botha, LR

    2009-10-01

    Full Text Available , “Optically Pumped Mid-Infrared HBr Laser,” IEEE J. Quantum Electron. 30(10), 2395–2400 (1994). 2. C. S. Kletecka, N. Campbell, C. R. Jones, J. W. Nicolson, and W. Rudolph, “Cascade Lasing of Molecular HBr in the Four Micron Region Pumped by a Nd:YAG laser...-Infrared Coherent Sources, (European Physical Society 2009) Invited Talk Mo3. 5. C. Bollig, H. J. Strauss, M. J. D. Esser, W. Koen, M.Schellhorn, D. Preussler, K. Nyangaza, C. Jacobs, E. H. Bernardi and L. R. Botha, “Compact Fibre-Laser-Pumped Ho:YLF Oscillator...

  11. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    Science.gov (United States)

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  12. Tape casting fabrication and properties of planar waveguide YAG/Yb:YAG/YAG transparent ceramics

    Science.gov (United States)

    Zhao, Yu; Liu, Qiang; Ge, Lin; Wang, Chao; Li, Wenxue; Yang, Chao; Wang, Juntao; Yuan, Lei; Xie, Tengfei; Kou, Huamin; Pan, Yubai; Gao, Qingsong; Bo, Yong; Peng, Qinjun; Xu, Zuyan; Li, Jiang

    2017-07-01

    Highly transparent YAG/10at.%Yb:YAG/YAG planar waveguide ceramics were fabricated by the non-aqueous tape casting and solid-state reactive sintering technology. The tapes are relatively homogeneous and the green body shows a dense structure without distinct interfaces after the treatment of debinding and cold isostatic pressing. YAG/10at.%Yb:YAG/YAG ceramics with almost full dense structure were obtained by vacuum-sintering at 1760 °C for 30 h. For the mirror-polished sample with the thickness of 3.5 mm, the In-line transmittance was measured to be 83.6% at the visual wavelength of 400 nm. The diffusion distance of the Yb3+ ions was about 215 μm along the thickness direction of the ceramics. In the lasing experiments, the YAG/10at.%Yb:YAG/YAG planar waveguide ceramics were end-pumped by a 976 nm semiconductor diode laser and enabled efficient continuous-wave lasers, which resulted in a maximum output power of 1.6 W and a slope efficiency of 34.4% at 1030 nm.

  13. Holmium laser lithotripsy (HoLL) of ureteral calculi

    Science.gov (United States)

    Kuntz, Rainer M.; Lehrich, Karin; Fayad, Amr

    2001-05-01

    The effectiveness and side effects of ureteroscopic HoLL of ureteral stones should be evaluated. In 63 patients (17 female, 46 males) a total of 75 stones of 3-20 mm diameter were treated with ureteroscopic HoLL. 18.7 percent of stones were located in the proximal third, 24.0 percent in the middle third and 57.3 percent in the distal third of the ureter. HoLL was performed with small diameter semirigid and flexible ureteroscopes, 220 or 365 nm flexible laser fibers and a holmium:YAG laser at a power of 5-15 W (0.5-1.0 J, 10- 15 Hz). 47 of 63 patients (74.6 percent) were immediately free of stones, and 8 others (12.6 percent) lost their residual fragments spontaneously within two weeks. Another 2 patients received additional chmolitholysis for uric acid stone fragments, i.e. 90.5 percent of patients were stone free by one sitting of ureterscopic HoLL. Of the remaining 6 patients (9.5 percent) who still had residual calculi 4 weeks after HoLL, 2 asymptomatic patients refused any additional treatment, 2 patients preferred treatment with ESWL, and 2 patients had a successful second HoLL, thereby raising the success rate of ureteroscopic HoLL to 93.7 percent. 2 patients showed contrast medium extravasation on retrograde ureterograms, due to guide wire perforation. No ureteral stricture occurred. In conclusion, transurethral ureteroscopic HoLL proved to be a safe and successful minimal invasive treatment of ureteral calculi.

  14. Ablation of Porcine Ligamentum Flavum with Ho:YAG, Q-Switched Ho:YAG, and Quadrupled Nd:YAG Lasers

    Science.gov (United States)

    2015-10-07

    majority of LSS patients is the  thickening of the collagenous connective tissue  bridging  the interlaminar spaces of the dorsal spinal  canal called the...dorsal surface of  the spinal canal and the associated LF segments  bridging  each vertebral level. LF was subsequently  excised from its superior and...secured to a  moveable  optical stage, allowing for very fine mechanical control of the laser‐fiber  relative to the LF. The optical stage was used to

  15. Diode laser-pumped Ho:YLF laser

    International Nuclear Information System (INIS)

    Hemmati, H.

    1987-01-01

    The author reports laser action in Ho:YLF at 2.06 μm following optical pumping with a cw diode laser array. Diode laser-pumped Nd-YAG and Ho:YAG have been reported recently. Lasers with a wavelength of 2 μm have medical and optical communication applications. The diode laser light is focused with a 60-mm focal length lens onto the YLF crystal. A high-reflectivity mirror with 100-mm radius of curvature was used as the output coupler. The lasing threshold was at 5 mWof incident power. This is higher than expected considering that a high reflector was used as the output coupler. However, a more uniform cooling of the crystal is expected to lower the lasing threshold. With 100 mW of pump power coupled into the crystal, --20 mW of 2-μm radiation was observed from this unoptimized setup. The 2-μm laser output is highly sensitive to output coupler alignment, YLF crystal temperature, and pump laser wavelength. The 20% optical conversion efficiency achieved in his preliminary measurements is expected to be improved by better crystal cooling, proper matching of laser wavelength to crystal absorption, variations in the concentration of Ho and sensitizers and use of a proper output coupler. A study of the parameters mentioned above and the effect of crystal temperature on the laser output is under way

  16. Advances in laser technology and fibre-optic delivery systems in lithotripsy.

    Science.gov (United States)

    Fried, Nathaniel M; Irby, Pierce B

    2018-06-08

    The flashlamp-pumped, solid-state holmium:yttrium-aluminium-garnet (YAG) laser has been the laser of choice for use in ureteroscopic lithotripsy for the past 20 years. However, although the holmium laser works well on all stone compositions and is cost-effective, this technology still has several fundamental limitations. Newer laser technologies, including the frequency-doubled, double-pulse YAG (FREDDY), erbium:YAG, femtosecond, and thulium fibre lasers, have all been explored as potential alternatives to the holmium:YAG laser for lithotripsy. Each of these laser technologies is associated with technical advantages and disadvantages, and the search continues for the next generation of laser lithotripsy systems that can provide rapid, safe, and efficient stone ablation. New fibre-optic approaches for safer and more efficient delivery of the laser energy inside the urinary tract include the use of smaller-core fibres and fibres that are tapered, spherical, detachable or hollow steel, or have muzzle brake distal fibre-optic tips. These specialty fibres might provide advantages, including improved flexibility for maximal ureteroscope deflection, reduced cross section for increased saline irrigation rates through the working channel of the ureteroscope, reduced stone retropulsion for improved stone ablation efficiency, and reduced fibre degradation and burnback for longer fibre life.

  17. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    Science.gov (United States)

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  18. Cryogenic Yb: YAG Thin-Disk Laser

    Science.gov (United States)

    2016-09-09

    as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG thin disk laser performance...Air Force Base, NM USA 87117 4RINI Technologies, 582 South Econ Circle, Oviedo, FL USA 32765 Keywords: Laser materials; Lasers, ytterbium...temperatures, Yb:YAG behaves as a 4- level laser. Its absorption and emission cross-sections increase, and its thermal conductivity improves. Yb:YAG

  19. Thermal lens measurements in the cornea.

    Science.gov (United States)

    Venkatesh, S; Guthrie, S; Cruickshank, F R; Bailey, R T; Foulds, W S; Lee, W R

    1985-02-01

    Q-switched pulses from a neodymium/YAG (yttrium-aluminium-garnet) laser were passed through corneal discs taken from the enucleated eyes of three baboons and four rabbits. The time course of heat dissipation following absorption of laser energy by the tissue was studied with the use of a second continuous wave laser beam acting as a probe. It was found that the absorption of each neodymium/YAG pulse created a transient divergent lens within the cornea as theoretical considerations predicted. The relaxation time that characterised the decay of this thermal lens for a 1/e laser beam diameter of 2.0 mm was found to be 2.3 +/- 0.1 s (mean +/- standard error for 12 separate groups of measurements). Our results show that Q-switched laser pulses passing through apparently unaffected transparent tissues can induce thermal lens effects which persist for several seconds. The optical transfer of each pulse in a stream will be identical only if enough time is left between pulses for the tissues to return to their initial state. Therefore, when such laser pulses sharply focused to perform high precision intraocular surgery are used, thermal lensing in the transparent ocular media must limit the rate at which pulses can be usefully delivered.

  20. Low-fluence 1,064-nm laser hair reduction for pseudofolliculitis barbae in skin types IV, V, and VI.

    Science.gov (United States)

    Schulze, Rafael; Meehan, Ken J; Lopez, Antonia; Sweeney, Kasina; Winstanley, Doug; Apruzzese, William; Victor Ross, E

    2009-01-01

    To evaluate the efficacy of a 1,064-nm neodymium-doped yttrium aluminium garnet (Nd:YAG) laser using lower than traditional fluences (22-40 J/cm(2)) for treatment of pseudofolliculitis barbae (PFB). Twenty-two patients with PFB refractory to conservative therapy received five weekly treatments over the anterior neck using a 1,064-nm Nd:YAG laser at 12 J/cm(2). Pulse duration was 20 ms with 10 mm spot size. Topical anesthesia was not used. Treatments were completed 15 minutes after patient arrival. Patients presented for 2- and 4-week follow-up. Ten evaluators used a Global Assessment Scale (GAS) to assess dyspigmentation, papule counts, and cobblestoning by comparing baseline to 4-week follow-up visit photographs. Hair and papule counts were performed on five patients and compared with the GAS. Investigators recorded adverse effects using a visual analog and side effects scale. Eleven patients demonstrated 83% improvement on the GAS (pPFB. Subjects noted minimal pain without topical anesthesia.

  1. Low-power holmium:YAG laser urethrotomy for treatment of urethral strictures: functional outcome and quality of life.

    Science.gov (United States)

    Kamp, Stefan; Knoll, Thomas; Osman, Mahmoud M; Köhrmann, Kai Uwe; Michel, Maurice S; Alken, Peter

    2006-01-01

    To evaluate the efficacy of endourethrotomy with the holmium:YAG laser as a minimally invasive treatment for urethral stricture. Between January 2002 and January 2004, 32 male patients with symptomatic urethral strictures (8 bulbar, 9 penile, 9 combined) were treated with Ho:YAG-laser urethrotomy in our department. The stricture was iatrogenic in 60% (N = 18), inflammatory in 16.6% (N = 5), traumatic in 13.3% (N = 4), and idiopathic in 7% (N = 3). The stricture was incised under vision at the 12 o'clock location or the site of maximum scar tissue or narrowing in asymmetric strictures. Laser energy was set on 1200 to 1400 mJ with a frequency of 10 to 13 Hz. Postoperatively, drainage of the bladder was performed for 4 days using a 18F silicone catheter. Triamcinolone was instilled intraurethrally after removal of the catheter in all patients. Patients were followed up by mailed questionnaire, including International Prostate Symptom Score and quality of life. Retrograde endoscopic Ho:YAG laser urethrotomy could be performed in all 32 patients. Most patients (22; 68.7%) did not need any reintervention. Ten patients developed recurrent strictures that were treated by another laser urethrotomy in 4 patients (12.5%), while 6 patients (18.7%) needed open urethroplasty with buccal mucosa. Including 2 patients treated with repeat laser urethrotomy, 24 patients (75%) were considered successful after a mean follow-up of 27 months (range 13-38 months). No intraoperative complications were encountered, although in 5% of patients, a urinary-tract infection was diagnosed postoperatively. No gross hematuria occurred. The Ho:YAG laser urethrotomy is a safe and effective minimally invasive therapeutic modality for urethral stricture with results comparable to those of conventional urethrotomy. Further data from long-time follow-up are necessary to compare the success rate with that of conventional urethrotomy and urethroplasty. Nevertheless, the Ho:YAG laser urethrotomy might at

  2. Long-term efficacy of microbiology-driven periodontal laser-assisted therapy.

    Science.gov (United States)

    Martelli, F S; Fanti, E; Rosati, C; Martelli, M; Bacci, G; Martelli, M L; Medico, E

    2016-03-01

    Periodontitis represents a highly prevalent health problem, causing severe functional impairment, reduced quality of life and increased risk of systemic disorders, including respiratory, cardiovascular and osteoarticular diseases, diabetes and fertility problems. It is a typical example of a multifactorial disease, where a polymicrobial infection inducing chronic inflammation of periodontal tissues is favoured by environmental factors, life style and genetic background. Since periodontal pathogens can colonise poorly vascularised niches, antiseptics and antibiotics are typically associated with local treatments to manage the defects, with unstable outcomes especially in early-onset cases. Here, the results of a retrospective study are reported, evaluating the efficacy of a protocol (Periodontal Biological Laser-Assisted Therapy, Perioblast™) by which microbial profiling of periodontal pockets is used to determine the extent and duration of local neodymium-doped yttrium aluminium garnet (Nd:YAG) laser irradiation plus conventional treatment. The protocol was applied multicentrically on 2683 patients, and found to produce a significant and enduring improvement of all clinical and bacteriological parameters, even in aggressive cases. Microbiome sequencing of selected pockets revealed major population shifts after treatment, as well as strains potentially associated with periodontitis in the absence of known pathogens. This study, conducted for the first time on such a large series, clearly demonstrates long-term efficacy of microbiology-driven non-invasive treatment of periodontal disease.

  3. Management of vascular lesions using advanced laser technology

    Directory of Open Access Journals (Sweden)

    Christofer Tzermias

    2017-04-01

    Full Text Available One of the most widely used cutaneous applications of Light Amplification by Stimulated Emission of Radiation (laser concerns the treatment of vascular lesions. During the past two decades, very significant advances in the application of laser technology in dermatology have occurred, with selective photothermolysis being the most important. This review focuses on the application of modern laser devices (Pulsed Dye Laser, or PDL; potassium titanyl phosphate laser, or KTP; diode laser; and neodymium-doped yttrium-aluminium-garnet laser, or Nd:YAG, as well as the combination of laser and photodynamic therapy (PDT for the treatment of vascular lesions. In particular, both congenital (haemangiomas and port-wine stains and acquired vascular lesions (facial and leg telangiectasias, rosacea, Poikiloderma of Civatte, spider angioma, pyogenic granuloma, and venous lakes are discussed. The review of many recent research studies demonstrates that modern applications of lasers in dermatology constitute the finest method for the treatment of vascular lesions, combining the advantages of invasive therapy with the security offered by non-invasive therapy, while in certain cases they are the single and only choice for the treatment of these lesions.

  4. Laser-induced breakdown spectroscopy and inductively coupled plasma-mass spectrometry for determination of Cr in soils from Brits District, South Africa

    Directory of Open Access Journals (Sweden)

    A. A. Ambushe

    2015-10-01

    Full Text Available Laser-induced breakdown spectroscopy (LIBS is an emerging analytical technique, which can be used to perform elemental analysis of any material, irrespective of its physical state. In this study, the LIBS technique has been applied for quantification of total Cr in soil samples collected from polluted areas of Brits, North West Province, South Africa. A Q-switched neodymium-yttrium aluminium garnet (Nd-YAG laser (10 Hz, λ = 1064 nm was employed for generation of a laser-induced plasma on the surface of the soil sample. The atomic emission lines were recorded using an Andor Shamrock SR-303i spectrometer, fitted with an intensified charge-coupled device (ICCD camera. Detailed investigation of experimental parameters such as gate delay time, gate width and laser pulse energy was conducted. Soil samples were dried, finely ground, sieved and thereafter pelletized before LIBS analysis. Calibration curve for the quantification of Cr was constructed using certified reference materials of soils and sediments. The concentrations of Cr in soil samples varied from 111 to 3180 mg/kg. In order to test the validity of the LIBS results, inductively coupled plasma-mass spectrometry (ICP-MS was also employed for determination of Cr. The results obtained using LIBS were found to be in good agreement with those of ICP-MS.DOI: http://dx.doi.org/10.4314/bcse.v29i3.3

  5. Automated Cart with VIS/NIR Hyperspectral Reflectance and Fluorescence Imaging Capabilities

    Directory of Open Access Journals (Sweden)

    Alan M. Lefcourt

    2016-12-01

    Full Text Available A system to take high-resolution Visible/Near Infra-Red (VIS/NIR hyperspectral reflectance and fluorescence images in outdoor fields using ambient lighting or a pulsed laser (355 nm, respectively, for illumination purposes was designed, built, and tested. Components of the system include a semi-autonomous cart, a gated-intensified camera, a spectral adapter, a frequency-triple Nd:YAG (Neodymium-doped Yttrium Aluminium Garnet laser, and optics to convert the Gaussian laser beam into a line-illumination source. The front wheels of the cart are independently powered by stepper motors that support stepping or continuous motion. When stepping, a spreadsheet is used to program parameters of image sets to be acquired at each step. For example, the spreadsheet can be used to set delays before the start of image acquisitions, acquisition times, and laser attenuation. One possible use of this functionality would be to establish acquisition parameters to facilitate the measurement of fluorescence decay-curve characteristics. The laser and camera are mounted on an aluminum plate that allows the optics to be calibrated in a laboratory setting and then moved to the cart. The system was validated by acquiring images of fluorescence responses of spinach leaves and dairy manure.

  6. Guidelines for removing permanent makeup

    Directory of Open Access Journals (Sweden)

    C.Bettina Rümmelein

    2016-09-01

    Full Text Available Permanent makeup (PMU is a frequently implemented cosmetic procedure performed by beauticians. From a technical point, PMU is considered a facial tattoo. Failed procedures or a change of mind can lead to the desire for removal. The purpose of this retrospective evaluation of patients who came to the clinic with the desire to remove PMU between 2011 and 2015 was to explore the problems, side effects, and results in order to define treatment guidelines for other doctors. We evaluated 87 individual cases in total. In treatable cases, i.e. 52 out of the 87 cases, laser treatments were performed using a nanosecond Q-switched neodymium-doped yttrium aluminium garnet (Nd:YAG laser. It takes between 1-12 treatments to remove the PMU. In three cases, the colour of the PMU could not be removed by laser and remained after the treatment. In two cases, laser treatment had to be terminated due to colour changes towards the green-blue spectrum. Before PMU removal, laser test shots are urgently recommended as unforeseeable colour changes can cause severe aesthetically unpleasant results. Covered up PMU (skin colour is particularly susceptible to changes in colour. Heat-induced shrinking of the eye area can cause an ectropium. Surgical solutions also have to be taken into consideration. The use of proper eye protection with intraocular eye shields is mandatory. This article is an attempt to set up some guidelines for the treatment of PMU removal.

  7. In-vitro study on haemodiluted blood flow in a sinusoidal microstenosis.

    Science.gov (United States)

    Kang, M J; Ji, H-S; Lee, S J

    2010-01-01

    In-vitro experiments were carried out to investigate the haemodynamic and haemorheological behaviours of haemodiluted blood flow through a microstenosis using a micro-particle image velocimetry (PIV) technique. The micro-PIV system employed in this study consisted of a two-head neodymium:yttrium-aluminium-garnet (Nd:YAG) laser, a cooled charge-coupled device camera, and a delay generator. To simulate blood flow in a stenosed vascular vessel, a polydimethylsiloxane (PDMS) microchannel with a sinusoidal throat of 80 per cent severity was employed. The width and depth of the microchannel were 100 microm and 50 microm, respectively. To compare the flow characteristics in the microstenosis, the same experiments were repeated in a straight microchannel under the same flow conditions. Using a syringe pump, human blood with 5 per cent haematocrit was supplied into the microstenosis channel. The flow characteristics and transport of blood cells through the microstenosis were investigated with various flowrates. The mean velocity fields were nearly symmetric with respect to the channel centreline. In the contraction section, the oncoming blood flow was accelerated rapidly, and the maximum velocity at the throat was almost 4.99 times faster than that of the straight microchannel without stenosis. In the diffusion section, the blood cells show rolling, deformation, twisting, and tumbling motion due to the flow-choking characteristics at the stenotic region. The results from this study will provide useful basic data for comparison with those obtained by clinical researchers.

  8. LiHo(PO34

    Directory of Open Access Journals (Sweden)

    Mokhtar Férid

    2009-02-01

    Full Text Available Lithium holmium(III polyphosphate(V, LiHo(PO34, belongs to the type I of polyphosphates with general formula ALn(PO34, where A is a monovalent cation and Ln is a trivalent rare earth cation. In the crystal structure, the polyphosphate chains spread along the b-axis direction, with a repeat period of four tetrahedra and 21 internal symmetry. The Li and Ho atoms are both located on twofold rotation axes and are surrounded by four and eight O atoms, leading to a distorted tetrahedral and dodecahedral coordination, respectively. The HoO8 polyhedra are isolated from each other, the closest Ho...Ho distance being 5.570 (1 Å.

  9. Study of structural and optical properties of YAG and Nd:YAG single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kostić, S. [Institute of Physics, University of Belgrade, P.O. Box 68, Pregrevica 118, Zemun, Belgrade (Serbia); Lazarević, Z.Ž., E-mail: lzorica@yahoo.com [Institute of Physics, University of Belgrade, P.O. Box 68, Pregrevica 118, Zemun, Belgrade (Serbia); Radojević, V. [Faculty of Technology and Metallurgy, University of Belgrade, Belgrade (Serbia); Milutinović, A.; Romčević, M.; Romčević, N.Ž. [Institute of Physics, University of Belgrade, P.O. Box 68, Pregrevica 118, Zemun, Belgrade (Serbia); Valčić, A. [Faculty of Technology and Metallurgy, University of Belgrade, Belgrade (Serbia)

    2015-03-15

    Highlights: • Transparent YAG and pale pink Nd:YAG single crystals were produced by the Czochralski technique. • Growth mechanisms and shape of the liquid/solid interface and incorporation of Nd{sup 3+} were studied. • The structure of the crystals was investigated by X-ray diffraction, Raman and IR spectroscopy. • The 15 Raman and 17 IR modes were observed. • The obtained YAG and Nd:YAG single crystals were without core and of good optical quality. - Abstract: Yttrium aluminum garnet (YAG, Y{sub 3}Al{sub 5}O{sub 12}) and yttrium aluminum garnet doped with neodymium (Nd:YAG) single crystals were grown by the Czochralski technique. The critical diameter and the critical rate of rotation were calculated. Suitable polishing and etching solutions were determined. As a result of our experiments, the transparent YAG and pale pink Nd:YAG single crystals were produced. The obtained crystals were studied by X-ray diffraction, Raman and IR spectroscopy. The crystal structure was confirmed by XRD. The 15 Raman and 17 IR modes were observed. The Raman and IR spectroscopy results are in accordance with X-ray diffraction analysis. The obtained YAG and Nd:YAG single crystals were without core and of good optical quality. The absence of a core was confirmed by viewing polished crystal slices. Also, it is important to emphasize that the obtained Nd:YAG single crystal has a concentration of 0.8 wt.% Nd{sup 3+} that is characteristic for laser materials.

  10. Densification behavior, doping profile and planar waveguide laser performance of the tape casting YAG/Nd:YAG/YAG ceramics

    Science.gov (United States)

    Ge, Lin; Li, Jiang; Qu, Haiyun; Wang, Juntao; Liu, Jiao; Dai, Jiawei; Zhou, Zhiwei; Liu, Binglong; Kou, Huamin; Shi, Yun; Wang, Zheng; Pan, Yubai; Gao, Qingsong; Guo, Jingkun

    2016-10-01

    The sintering behavior and doping concentration profile of the planar waveguide YAG/Nd:YAG/YAG ceramics by the tape casting and solid-state reaction method were investigated on the basis of densification trajectory, microstructure evolution, and Nd3+ ions diffusion. The porosity of the green body by tape casting and cold isostatic pressing is about 38.6%. And the green bodies were consolidated from 1100 °C to 1800 °C for 0.5-20 h to study the densification and the doping diffusion behaviors. At the temperature higher than 1500 °C, pure YAG phase is formed, followed by the densification and grain growth process. With the increase of temperature, two sintering stages occur, corresponding to remarkable densification and significant grain growth, respectively. The mechanism controlling densification at 1550 °C is grain boundary diffusion. The diffusion of Nd3+ ions is more sensitive to temperature than the sintering time, and the minimum temperature required for the obvious diffusion of Nd3+ ions is higher than 1700 °C. Finally, planar waveguide YAG/1.5 at.%Nd:YAG/YAG transparent ceramics with in-line transmittance of 84.8% at 1064 nm were obtained by vacuum-sintering at 1780 °C for 30 h. The fluorescence lifetime of 4F3/2 state of Nd3+ in the specimen is about 259 μs. The prepared ceramic waveguide was tested in a laser amplifier and the laser pulse was amplificated from 87 mJ to 238 mJ, with the pump energy of 680 mJ.

  11. Preparation and characterization of highly transparent Nd:YAG/YAG composite ceramics

    Science.gov (United States)

    Ma, Benyuan; Zhang, Wei; Shen, Bizhou; Wang, Yuezhong; Song, Haizhi; Li, Feng; Xie, Xiumin; Zhang, Zhibin; Yang, Yongqiang; Guan, Zhouguo

    2018-05-01

    Using the co-precipitated Nd:YAG and YAG powders as raw materials, the Nd:YAG/YAG composite ceramics (Ф 50 mm × 5 mm) were prepared by vacuum sintering (1790 °C 50 h), followed by hot isostatic pressing (HIP) post treatment (1700 °C 2 h, 200 MPa Ar atmosphere) and air annealing (1250 °C 100 h). The optical properties of Nd:YAG/YAG samples were improved markedly by HIP post-treatment, mainly due to the elimination of residual pores in the samples. The composite sample showed a perfect bonding interface from Nd:YAG to YAG regions without obvious grain size difference, pores or other defects. This structure should be responsible for the thermal conductivity larger than that of non-composite sample. The composite sample revealed good optical properties with transmittance up to 83.9% at 1064 nm and 80.8% at 400 nm, and a maximum laser output power of 1.38 KW with the slope efficiency of 36.7% was obtained.

  12. Shape coexistence in 153Ho

    International Nuclear Information System (INIS)

    Dey, Gautam; Sarkar, S.; Chakraborty, A.; Krishichayan; Ghugre, S.S.; Sinha, A.K.; Kshetri, Ritesh; Ray, I.; Ganguly, S.; Pradhan, M.K.; Raut, R.; Goswami, A.; Banerjee, P.; Mukherjee, A.; Bhattacharya, S.; Saha Sarkar, S.; Ray Basu, M.; Ganguly, G.; Ray, M.; Basu, S.K.

    2006-01-01

    The motivation for the present work are to firmly assign spins and parities of the excited levels and to investigate shape evolution in 153 Ho as expected phenomenologically from the level spectra and feeding patterns

  13. Holmium:YAG Laser Ablation for the Management of Lower Urinary Tract Foreign Bodies Following Incontinence Surgery: A Case Series and Systematic Review.

    Science.gov (United States)

    Chan, Garson; Mamut, Adiel; Martin, Paul; Welk, Blayne

    2016-11-01

    The objective of this study was to determine the outcomes associated with the endoscopic removal of foreign bodies (such as mesh or permanent suture) in the lower urinary tract after female stress incontinence surgery with the Holmium:YAG (Ho:YAG) laser, and to systematically review the literature on this topic. A retrospective chart review of 18 consecutive women found to have mesh or suture exposure was performed. All patients underwent Ho:YAG laser ablation. A systematic review was performed to identify literature addressing the endoscopic management of mesh/suture exposure after stress incontinence surgery. Between November 2011 and February 2016, 18 women underwent Ho:YAG laser ablation of exposed mesh or suture. Presenting symptoms included lower urinary tract symptoms, pelvic pain, incontinence, or recurrent urinary tract infections. Thirteen women had a previous synthetic midurethral sling and five had a prior retropubic suspension. The median age was 58 years (interquartile range [IQR] 50-60) and median follow-up was 2 years (IQR 1-2). Four patients (22%) had residual mesh after the first procedure, requiring a repeat endoscopic procedure. Only one patient had a small amount of asymptomatic residual mesh on cystoscopy after the final procedure. Only minor postoperative complications were observed. Eight patients had stress incontinence and four underwent operative treatment for this. In our systematic review, we identified 16 case series, which described a total of 158 patients. Women most commonly presented with voiding symptoms or incontinence. Based on the synthesis of these data, repeat procedures were necessary in 16% and vesicovaginal fistula occurred in 2%. Recurrent/persistent stress incontinence was present in 20%, and of these patients, 3/4 underwent a new stress incontinence procedure. Both our case series and the systematic review of the literature demonstrated that endoscopic treatment of lower urinary tract foreign bodies after stress

  14. Performance and safety of holmium: YAG laser optical fibers.

    Science.gov (United States)

    Knudsen, Bodo E; Glickman, Randolph D; Stallman, Kenneth J; Maswadi, Saher; Chew, Ben H; Beiko, Darren T; Denstedt, John D; Teichman, Joel M H

    2005-11-01

    Lower-pole ureteronephroscopy requires transmission of holmium:YAG energy along a deflected fiber. Current ureteroscopes are capable of high degrees of deflection, which may stress laser fibers beyond safe limits during lower-pole use. We hypothesized that optical fiber and safety measures differ among manufacturers. Small (200-273-microm) and medium-diameter (300-400-microm) Ho:YAG fibers were tested in a straight and 180 degrees bent configuration. Energy transmission was measured by an energy detector. Fiber durability was assessed by firing the laser in sequentially tighter bending diameters. The fibers were bent to 180 degrees with a diameter of 6 cm and run at 200- to 4000-mJ pulse energy to determine the minimum energy required to fracture the fiber. The bending diameter was decreased by 1-cm increments and testing repeated until a bending diameter of 1 cm was reached. The maximum deflection of the ACMI DUR-8E ureteroscope with each fiber in the working channel was recorded. The flow rate through the working channel of the DUR-8E was measured for each fiber. The mean energy transmission differed among fibers (P < 0.001). The Lumenis SL 200 and the InnovaQuartz 400 were the best small and medium-diameter fibers, respectively, in resisting thermal breakdown (P < 0.01). The Dornier Lightguide Super 200 fractured repeatedly at a bend diameter of 2 cm and with the lowest energy (200 mJ). The other small fibers fractured only at a bend diameter of 1 cm. The Sharplan 200 and InnovaQuartz Sureflex 273T were the most flexible fibers, the Lumenis SL 365 the least. The flow rate was inversely proportional to four times the power of the diameter of the fiber. Optical performance and safety differ among fibers. Fibers transmit various amounts of energy to their cladding when bent. During lower-pole nephroscopy with the fiber deflected, there is a risk of fiber fracture from thermal breakdown and laser-energy transmission to the endoscope. Some available laser fibers

  15. Bouveret's syndrome complicated by distal gallstone ileus after laser lithotropsy using Holmium: YAG laser

    Directory of Open Access Journals (Sweden)

    Rodgers John B

    2002-06-01

    Full Text Available Abstract Background Bouveret's syndrome is an unusual presentation of duodenal obstruction caused by the passage of a large gallstone through a cholecystoduodenal fistula. Endoscopic therapy has been used as first-line treatment, especially in patients with high surgical risk. Case presentation We report a 67-year-old woman who underwent an endoscopic attempt to fragment and retrieve a duodenal stone using a Holmium: Yttrium-Aluminum-Garnet Laser (Ho:YAG which resulted in small bowel obstruction. The patient successfully underwent enterolithotomy without cholecystectomy or closure of the fistula. Conclusion We conclude that, distal gallstone obstruction, due to migration of partially fragmented stones, can occur as a possible complication of laser lithotripsy treatment of Bouveret's syndrome and might require urgent enterolithotomy.

  16. Beam delivery system for Ho:YLF and applications in endodontics; Sistema de entrega de feixe para laser de Ho:YLF e aplicacoes em endodontia

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Luciano

    2000-07-01

    The beam delivery systems, whether using fibers or articulated arms, are very important for the expansion of laser applications into life sciences. This work aims to couple an optical fiber to a home-made Er:Tm:Ho:LiYF{sub 4} laser. For this purpose the beam profile was studied using the beam quality factor M{sup 2} to achieve an homogeneous beam. To determine the M{sup 2} factor, the knife-edge technique was used, relating the laser energy eclipsed by the knife with its transversal position. The resonant cavity was made suitable in order to obtain a stable and homogeneous transversal beam profile, for the optical fiber coupling. It was used a 365 {mu}m diameter core low OH{sup -} content fused silica optical fiber, with a proximal SMA-905 connection and a flat distal end. M{sup 2} factors for the Ho:YLF were between 3 and 8, with a non astigmatic beam, although it was observed a divergence asymmetry in the transversal sections. The coupling efficiency was 96%, and in a repeated operation without any adjustment, the new coupling were 82% and 81%. Lasers have being recently used as an adjunct to conventional endodontic preparation to reduce intracanal microbial, preventing reinfection. The knowledge of thermal profile in endodontic procedures is important to determine laser irradiation conditions avoiding periodontal damages. In this sense, the second scope of this work was to use the Ho:YLF system to register the thermal profile in vitro and to compare the results with those obtained with Nd:YAG and Er:YAG commercial lasers. The temperature was recorded in real time through a thermocouple probe at the root apex , resulting in maximum increase of 7 deg C. (author)

  17. Actively Q-switched laser with novel Nd:YAG/YAG polygonal active-mirror

    Science.gov (United States)

    Lang, Ye; Chen, Yanzhong; Ge, Wenqi; He, Jianguo; Zhang, Hongbo; Liao, Lifen; Xin, Jianguo; Zhang, Jian; Fan, Zhongwei

    2018-03-01

    In this work, we demonstrate an efficient actively Q-switched laser based on a novel crystal Nd:YAG/YAG polygonal active mirror. A passively cooled crystal Nd:YAG/YAG polygonal active mirror with an end pump scheme was used as the gain medium. For the overlap between the TEM00 laser mode and large gain profile, a cavity was carefully designed with a large fundamental mode volume. With a maximum absorbed power of 3.1 W, a 685 mW average output power with a pulse repetition of 5 kHz was attained, and the corresponding optical-optical and slope efficiency were 22.1% and 27.7%, respectively. The pulse width was 133.9 ns. The beam quality (M 2) was 1.561 in the horizontal direction and 1.261 in the vertical direction.

  18. ILLICO-HO

    International Nuclear Information System (INIS)

    Ougouag, A.M.; Rajic, H.L.

    1988-01-01

    A self-consistent nodal method has been developed that directly computes the in-node flux shapes. The method renders the use of an approximation for the transverse leakages no longer necessary. These are obtained directly from the available interface net current shapes, interface flux shapes, and in-node fluxes. The order of the transverse leakage expansion on a set of Legendre polynomials is determined by the order chosen for the method. The results yielded are nearly as accurate (0.02% maximum relative assembly power error) as very fine-mesh benchmark solutions. A comprehensive numerical and analytical analysis of the transverse leakage approximation has been performed. It has been shown that the quadratic leakage approximation can be in error by many times its value. The success of the quadratic leakage approximation is attributed to its small effect on the nodal powers. The theory developed shows that the transverse leakages can have shapes that encompass hyperbolic sines and cosines, and hence that their approximation via quadratic expansions should not always be expected to be adequate. The ILLICO-HO method gives much more information (detailed fluxes and interface currents) than comparable finite difference as well as nodal benchmark solution methods

  19. Nd:YAG laser for holography

    International Nuclear Information System (INIS)

    Bykovsky, Yu.A.; Evtihiev, N.N.; Larkin, A.I.

    1982-01-01

    Different possibilities to use photonics, holography and optical processing for nuclear physics has been investigated in our works. The paper presents the results of the study of time and spatial coherence of Nd:YAG laser and application in holography. (orig./HSI)

  20. Spectroscopy and microchip laser operation of Tm, Ho:KYW crystals with different Ho concentrations

    Science.gov (United States)

    Gusakova, N. V.; Kurilchik, S. V.; Yasukevich, A. S.; Kisel, V. E.; Dashkevich, V. I.; Orlovich, V. A.; Pavlyuk, A. A.; Vatnik, S. M.; Bagaev, S. N.; Kuleshov, N. V.

    2018-02-01

    The spectroscopic properties of Tm, Ho:KYW crystals with different Ho concentrations were investigated. The diode-pumped microchip laser operation of Tm (5 at.%), Ho (0.5 at.%):KYW and Tm (5 at.%), Ho (1 at.%):KYW was demonstrated. The highest, to our knowledge, output power of 480 mW with slope efficiency of 31% for CW Tm (5 at.%), Ho (0.5 at.%):KYW microchip laser was obtained.

  1. Pulsed liquid jet dissector using holmium: YAG laser - a novel neurosurgical device for brain incision without imparing vessels

    International Nuclear Information System (INIS)

    Hirano, T.; Nakagawa, A.; Jokura, H.; Shirane, R.; Uenohara, H.; Ohyama, H.; Takayama, K.

    2003-01-01

    Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. The prototype device consisted of an optical fiber, a Y adapter, and a nozzle whose internal exit diameter was 100 μm. Cold physiological saline (4 o C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fiber end and nozzle exit (equivalent to the Standoff distance). With this device (3 Hz operation), brain dissection of anesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. When the Standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 μm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 o C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements. (author)

  2. High-Power Dual-End-Pumped Actively Q-Switched Ho:YAG Ceramic Laser

    Science.gov (United States)

    Duan, Xiao-Ming; Yuan, Jin-He; Yao, Bao-Quan; Dai, Tong-Yu; Li, Jiang; Pan, Yu-Bai

    2015-10-01

    Not Available Supported by the National Natural Science Foundation of China under Grant Nos 61308009, 61405047 and 50990301, the China Postdoctoral Science Foundation Funded Project under Grant No 2015T80339, the Fundamental Research Funds for the Central Universities under Grant No HIT.NSRIF.2015042, and the Science Fund for Outstanding Youths of Heilongjiang Province under Grant No JQ201310.

  3. Energy levels of Ho3+ in HoCl63-

    International Nuclear Information System (INIS)

    Tanner, P.A.

    1987-01-01

    The 5 S 2 , 5 F 4 , 5 F 2 , 3 K 8 , 5 G 6 , 5 F 1 , 5 G 5 5 I 8 absorption spectra of Cs 2 NaHoCl 6 have been recorded at temperatures down to that of liquid helium and new assignments are made for the 5 S 2 , 5 F 4 , 3 K 8 and 5 G 5 terms of HoCl 6 3- . The 5 F 3 → 5 I 8 , 5 F 4 , 5 S 2 → 5 I 7 , 5 I 8 and 5 F 5 → 5 I 7 luminescence transitions of HoCl 6 3- in various elpasolite lattices are reported and assigned, together with luminescence decay measurements. Including the previously reported data, these results enable 57 of the first 60 crystal-field levels of HoCl 6 3- , comprising 14 Lsub(j) terms, to be firmly assigned and tentative assignments are made for the remaining three levels. The agreement between the calculated and observed crystal-field splittings is reasonable. (author)

  4. Influence of temperature on Yb:YAG/Cr:YAG microchip laser operation

    Science.gov (United States)

    Šulc, Jan; Eisenschreiber, Jan; Jelínková, Helena; Nejezchleb, Karel; Å koda, Václav

    2017-02-01

    The goal of this work was an investigation of the temperature influence (in range from 80 up to 320 K) on the laser properties of Yb:YAG/Cr:YAG Q-switched diode-pumped microchip laser. This laser was based on monolith crystal (diameter 3mm) which combines in one piece an active laser part (Yb:YAG crystal, 10 at.% Yb/Y, 3mm long) and saturable absorber (Cr:YAG crystal, 1.36mm long, initial transmission 90% @ 1031 nm). The laser resonator pump mirror (HT for pump radiation, HR for generated radiation) was directly deposited on the Yb:YAG monolith part. The output coupler with reflection 55% for the generated wavelength was placed on the Cr:YAG part. The microchip laser was placed in the temperature controlled cupreous holder inside vacuum chamber of the liquid nitrogen cryostat. For Yb:YAG part longitudinal pulsed pumping (pumping pulse length 2.5 ms, rep-rate 20 Hz, power amplitude 21W) a fibre coupled (core diameter 400 μm, NA= 0:22) laser diode, operating at wavelength 933 nm, was used. The microchip laser mean output power, pulse duration, repetition rate, emission wavelength, and laser beam profile were measured in dependence on temperature. The generated pulse length was in range from 2.2 ns to 1.1 ns (FWHM) with the minimum at 230 K. The single pulse energy was peaking (0.4 mJ) at 180 K. The highest peak power (325 kW) was obtained at 220 K. The highest pulse repetition rate (38 kHz) and output mean power (370mW) was reached for temperature 80 K.

  5. On 165Ho level scheme

    International Nuclear Information System (INIS)

    Ardisson, Claire; Ardisson, Gerard.

    1976-01-01

    A 165 Ho level scheme was constructed which led to the interpretation of sixty γ rays belonging to the decay of 165 Dy. A new 702.9keV level was identified to be the 5/2 - member of the 1/2 ) 7541{ Nilsson orbit. )] [fr

  6. Beam delivery system for Ho:YLF and applications in endodontics

    International Nuclear Information System (INIS)

    Bachmann, Luciano

    2000-01-01

    The beam delivery systems, whether using fibers or articulated arms, are very important for the expansion of laser applications into life sciences. This work aims to couple an optical fiber to a home-made Er:Tm:Ho:LiYF 4 laser. For this purpose the beam profile was studied using the beam quality factor M 2 to achieve an homogeneous beam. To determine the M 2 factor, the knife-edge technique was used, relating the laser energy eclipsed by the knife with its transversal position. The resonant cavity was made suitable in order to obtain a stable and homogeneous transversal beam profile, for the optical fiber coupling. It was used a 365 μm diameter core low OH - content fused silica optical fiber, with a proximal SMA-905 connection and a flat distal end. M 2 factors for the Ho:YLF were between 3 and 8, with a non astigmatic beam, although it was observed a divergence asymmetry in the transversal sections. The coupling efficiency was 96%, and in a repeated operation without any adjustment, the new coupling were 82% and 81%. Lasers have being recently used as an adjunct to conventional endodontic preparation to reduce intracanal microbial, preventing reinfection. The knowledge of thermal profile in endodontic procedures is important to determine laser irradiation conditions avoiding periodontal damages. In this sense, the second scope of this work was to use the Ho:YLF system to register the thermal profile in vitro and to compare the results with those obtained with Nd:YAG and Er:YAG commercial lasers. The temperature was recorded in real time through a thermocouple probe at the root apex , resulting in maximum increase of 7 deg C. (author)

  7. Nd: YAG laser in art works restoration

    International Nuclear Information System (INIS)

    Flores, T.; Ponce, L.; Arronte, M.; Moreno, B.; Fernandez, M.; Garcia, C.

    1998-01-01

    Laser cleaning in works of art has a number of advantages over traditional techniques of restoration. In this article, the technique used and the physical mechanisms that explain the process of ablation of pollutants are described. The results obtained in the cleaning of statues of marble and alabaster are exposed as well as oil-painting restoration. In this last specific case, the Nd: YAG laser is used with successful results. (Author) 6 refs

  8. CTE:YAG laser applications in dentistry

    Science.gov (United States)

    Shori, Ramesh K.; Fried, Daniel; Featherstone, John D. B.; Kokta, Milan R.; Duhn, Clifford W.

    1998-04-01

    The suitability of CTE:YAG laser radiation was investigated for caries preventive laser treatments and caries ablation. Although, CTE:YAG laser radiation at 2.69 micrometer is less highly absorbed by dental hard tissues than other erbium laser wavelengths, namely 2.79 and 2.94 micrometer, it can readily be transmitted through a conventional low hydroxyl fiber with minimal loss. These studies show that reasonable ablation rates and efficiencies are obtainable with both free running (200 microseconds) and Q-switched (100 ns) laser pulses on both dentin and enamel with the application of a relatively thick layer of water to the tissue surface. The water served to remove tissue char and debris from the ablation site leaving a clean crater. However, mechanical forces produced during the energetic ablative process resulted in peripheral mechanical damage to the tissue. Surface dissolution studies on enamel indicated that CTE:YAG radiation inhibited surface dissolution by organic acid by 60 - 70% compared to unirradiated controls, albeit, at fluences an order of magnitude higher than those required for CO2 laser radiation. This layer system may be suitable for dental hard tissue applications if mechanical damage can be mitigated. This work was supported by NIH/NIDR Grants R29DE12091 and R01DE09958.

  9. Stone retropulsion during holmium:YAG lithotripsy.

    Science.gov (United States)

    Lee, Ho; Ryan, R Tres; Teichman, Joel M H; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Welch, A J

    2003-03-01

    We modeled retropulsion during holmium:YAG lithotripsy on the conservation of momentum, whereby the force of ejected fragment debris off of the calculous surface should equal the force of retropulsion displacing the stone. We tested the hypothesis that retropulsion occurs as a result of ejected stone debris. Uniform calculous phantoms were irradiated with holmium:YAG energy in air and in water. Optical fiber diameter and pulse energy were varied. Motion of the phantom was monitored with high speed video imaging. Laser induced crater volume and geometry were characterized by optical coherence tomography. To determine the direction of plume laser burn paper was irradiated at various incident angles. Retropulsion was greater for phantoms irradiated in air versus water. Retropulsion increased as fiber diameter increased and as pulse energy increased (p <0.001). Crater volumes increased as pulse energy increased (p <0.05) and generally increased as fiber diameter increased. Crater geometry was wide and shallow for larger fibers, and narrow and deeper for smaller fibers. The ejected plume propagated in the direction normal to the burn paper surface regardless of the laser incident angle. Retropulsion increases as pulse energy and optical fiber diameter increase. Vector analysis of the ejected plume and crater geometry explains increased retropulsion using larger optical fibers. Holmium:YAG lithotripsy should be performed with small optical fibers to limit retropulsion.

  10. Laser-diode pumped Nd:YAG lasers; Laser diode reiki Nd:YAG lasear

    Energy Technology Data Exchange (ETDEWEB)

    Yuasa, H.; Akiyama, Y.; Nakayama, M. [Toshiba Corp., Tokyo (Japan)

    2000-04-01

    Laser-diode pumped Nd:YAG lasers are expected to be applied to laser processing fields such as welding, cutting, drilling, and marking due to their potential for high efficiency and compactness. We are designing and developing laser-diode pumped Nd:YAG lasers using numerical analysis simulation techniques such as ray tracing and thermal analysis. We have succeeded in achieving a laser power of more than 3 kW with 20% efficiency, which is the best ever obtained. In addition, we have developed a laser-diode pumped green laser by second harmonic generation, for precision machining on silicon wafers. (author)

  11. Histological and Thermometric Examination of Soft Tissue De-Epithelialization Using Digitally Controlled Er:YAG Laser Handpiece: An Ex Vivo Study.

    Science.gov (United States)

    Grzech-Leśniak, Kinga; Matys, Jacek; Jurczyszyn, Kamil; Ziółkowski, Piotr; Dominiak, Marzena; Brugnera Junior, Aldo; Romeo, Umberto

    2018-06-01

    The purpose of this study was histological and thermometric examination of soft tissue de-epithelialization using digitally controlled laser handpiece (DCLH) - X-Runner. Commonly used techniques for de-epithelialization include scalpel, abrasion with diamond bur, or a combination of the two. Despite being simple, inexpensive and effective, these techniques are invasive and may produce unwanted side effects. It is important to look for alternative techniques using novel tools, which are minimally invasive and effective. 114 porcine samples sized 6 × 6 mm were collected from the attached gingiva (AG) of the alveolar process of the mandible using 15C scalpel blade. The samples were irradiated by means of Er:YAG laser (LightWalker, Fotona, Slovenia), using X-Runner and HO 2 handpieces at different parameters; 80, 100, and 140 mJ/20 Hz in time of 6 or 16 sec, respectively. The temperature was measured with a K-type thermocouple. For the histopathological analysis of efficiency of epithelium removal and thermal injury, 3 random samples were de-epithelialized with an HO 2 handpiece, and 9 random samples with an X-Runner handpiece with different parameters. For the samples irradiated with DCLH, we have used three different settings, which resulted in removing 1 to 3 layers of the soft tissue. The efficiency of epithelium removal and the rise of temperature were analyzed. DCLH has induced significantly lower temperature increase compared with HO 2 at each energy to frequency ratio. The histological examination revealed total epithelium removal when HO 2 handpiece was used at 100 and 140 mJ/20 Hz and when DCLH was used for two- and threefold lasing at 80, 100, and 140 mJ/20 Hz. Er:YAG laser with DCLH handpiece may be an efficient tool in epithelium removal without excessive thermal damage.

  12. CW laser properties of Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG mixed crystals

    Science.gov (United States)

    Di, J. Q.; Xu, X. D.; Li, D. Z.; Zhou, D. H.; Wu, F.; Zhao, Z. W.; Xu, J.; Tang, D. Y.

    2011-10-01

    Three mixed crystals, Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG, were grown by Czochralski method. We report the continuous-wave (CW) Nd:GdYAG, Nd:LuYAG, and Nd:GdLuAG laser operation under laser diode pumping. The maximum output powers are 4.11, 5.31, and 7.47 W, with slope efficiency of 73.0, 55.3, and 57.1%, respectively. With replacing Lu3+ or Y3+ ions with large Gd3+ ions, the pump efficiency increases.

  13. Phase separation, crystallization and polyamorphism in the Y{sub 2}O{sub 3}-Al{sub 2}O{sub 3} system

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, Lawrie B; Barnes, Adrian C [H H Wills Physics Laboratory, Royal Fort, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Salmon, Philip S [Department of Physics, University of Bath, Bath BA2 7AY (United Kingdom); Crichton, Wilson A [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, BP 220, Grenoble Cedex, F-38043 (France)], E-mail: a.c.barnes@bristol.ac.uk

    2008-05-21

    A detailed study of glass formation from aerodynamically levitated liquids in the (Y{sub 2}O{sub 3}){sub x}(Al{sub 2}O{sub 3}){sub 1-x} system for the composition range 0.21{<=}x{<=}0.41 was undertaken by using pyrometric, optical imaging and x-ray diffraction methods. Homogeneous and clear single-phase glasses were produced over the composition range 0.27{<=}x{<=}0.33. For Y{sub 2}O{sub 3}-rich compositions (0.33{<=}x{<=}0.375), cloudy materials were produced which contain inclusions of crystalline yttrium aluminium garnet (YAG) of diameter up to 40 {mu}m in a glassy matrix. For Y{sub 2}O{sub 3}-poor compositions around x = 0.24, cloudy materials were also produced, but it was not possible to deduce whether this resulted from (i) sub-micron inclusions of a nano-crystalline or glassy material in a glassy matrix or (ii) a glass formed by spinodal decomposition. For x = 0.21, however, the sample cloudiness results from crystallization into at least two phases comprising yttrium aluminium perovskite and alumina. The associated pyrometric cooling curve shows slow recalescence events with a continuous and slow evolution of excess heat which contrasts with the sharp recalescence events observed for the crystallization of YAG at compositions near x = 0.375. The materials that are the most likely candidates for demonstrating homogeneous nucleation of a second liquid phase occur around x = 0.25, which corresponds to the limit for formation of a continuous random network of corner-shared AlO{sub 4} tetrahedra.

  14. Shape coexistence in 153Ho

    Science.gov (United States)

    Pramanik, Dibyadyuti; Sarkar, S.; Saha Sarkar, M.; Bisoi, Abhijit; Ray, Sudatta; Dasgupta, Shinjinee; Chakraborty, A.; Krishichayan, Kshetri, Ritesh; Ray, Indrani; Ganguly, S.; Pradhan, M. K.; Ray Basu, M.; Raut, R.; Ganguly, G.; Ghugre, S. S.; Sinha, A. K.; Basu, S. K.; Bhattacharya, S.; Mukherjee, A.; Banerjee, P.; Goswami, A.

    2016-08-01

    The high-spin states in 153Ho have been studied by the La57(20Ne139,6 n ) reaction at a projectile energy of 139 MeV at the Variable Energy Cyclotron Centre (VECC), Kolkata, India, utilizing an earlier campaign of the Indian National Gamma Array (INGA) setup. Data from γ -γ coincidence, directional correlation, and polarization measurements have been analyzed to assign and confirm the spins and parities of the levels. We have suggested a few additions and revisions of the reported level scheme of 153Ho. The RF-γ time difference spectra have been useful to confirm the half-life of an isomer in this nucleus. From the comparison of experimental and theoretical results, it is found that there are definite indications of shape coexistence in this nucleus. The experimental and calculated lifetimes of several isomers have been compared to follow the coexistence and evolution of shape with increasing spin.

  15. Compensation for the temperature drift of the wavelength adjustment in an acoustooptic spectrophotometer

    International Nuclear Information System (INIS)

    Vilenskii, A V; Lysoi, B G; Cherednichenko, O B

    2002-01-01

    It is shown that the temperature drift of the wavelength adjustment in acoustooptic spectrophotometers can be compensated by using the reference channel of the spectrophotometer in which the absorption lines of neodymium-doped yttrium - aluminium garnet are employed as reference lines.

  16. Browse Title Index

    African Journals Online (AJOL)

    Vol 11, No 4 (2005), The hydrogen atom in a magnetic field, Abstract PDF. EO Ajala. Vol 8, No 1 (2002), The impedance measure of yttrium aluminium garnet doped ... The study of epoxy polyamide and polyvinyl resins as corrosion protective ... The tempering quality evaluation of cocoa liquor during industrial production ...

  17. Systematic hardness measurements on some rare earth garnet ...

    Indian Academy of Sciences (India)

    Unknown

    Microhardness measurements were undertaken on twelve rare earth garnet crystals. In yttrium aluminium garnet and gadolinium ... syan (1997) has quoted a single value for Gd3Sc2Ga3O12. In the present study measurements have ... small and within the limits of experimental error. There- fore, where pure garnet crystals ...

  18. High power YAG laser cutting; Koshutsuryoku YAG laser ni yoru setsudan gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    Owaki, K. [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1998-08-01

    This paper describes features of high power YAG cutting. The optical fiber transmission YAG laser machining system has some advantages in which optical path length compensation unit is not required and measures for low power loss and dust are not required, when compared with the CO2 laser system. Its application to the cutting of stainless steel plates has attracted attention. Cutting tests of SUS304 were conducted using high power YAG laser. Cutting of SUS304 plate with a thickness of 40 mm could be successfully done at the power of 3.5 kW. Cutting tests of SUS304 pipes with a thickness of 8 mm in water under the depth of 20 m were also conducted using air as assist gas at the power of 2.5 kW. Excellent results were obtained without scale deposition. For the tests by the composite beam using 3 kW and 4 kW systems, SUS304 plate with a thickness of 50 mm could be cut at the cutting speed of 0.1 m/min. Laser cutting of pipes from the internal surface was conducted using a newly developed small machining head which can rotate in the peripheral direction. Excellent quality for welding was confirmed. Cutting speed and plate thickness were improved by combining water jet cutter and YAG laser unit. 6 refs., 10 figs.

  19. Magnetic excitations in Ho2Co17 and Ho2Fe17

    International Nuclear Information System (INIS)

    Clausen, K.N.

    1981-01-01

    The low energy part ( 2 Co 17 and Ho 2 Fe 17 have been measured along the three high symmetry directions at a temperature of 4.2 K, using the inelastic neutron scattering technique. The resulting magnon dispersion relations have been interpreted using linear spin wave theory with a Hamiltonian including single ion crystal field anisotropy and isotropic exchange between spatially well localized spins. The R 2 T 17 structure contains two different Ho sites, with the same point symmetry, and from the spin wave results it was concluded that the crystal field anisotropy of the two Ho sites in both Ho 2 Co 17 and Ho 2 Fe 17 were identical. The deduced crystal field parameters for Ho 2 Fe 17 were slightly larger than for Ho 2 Co 17 , and the parameters were of the same order of magnitude as for pure Ho. For Ho 2 Fe 17 the Fe-Fe exchange was found to be anisotropic, and for both compounds the magnetic ordering temperatures of 1178 K for Ho 2 Co 17 and 335 K for Ho 2 Fe 17 were determined by the strong positive 3d-3d exchange. (Auth.)

  20. Short-wavelength luminescence in Ho{sup 3+}-doped KGd(WO{sub 4}){sub 2} crystals

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, M., E-mail: m.malinowski@elka.pw.edu.p [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Kaczkan, M.; Stopinski, S.; Piramidowicz, R. [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Majchrowski, A. [Institute of Applied Physics, Military University of Technology, Kaliskiego 2, 00-908 Warsaw (Poland)

    2009-12-15

    Emissions from the high-lying excited states, energy transfer and upconversion processes are investigated in Ho{sup 3+}-activated KGd(WO{sub 4}){sub 2} crystal. The spectral assignment based on time-resolved emission spectra allowed to identify various near ultra-violet (UV), blue and green emissions starting from the excited {sup 3}H{sub 5}, {sup 5}G{sub 4}, {sup 5}G{sub 5}, {sup 5}F{sub 3} and {sup 5}S{sub 2} levels. The temporal behavior of these transitions after pulsed excitation was analyzed as a function of temperature and holmium ions concentration. The shortening and nonexponentiality of the decays, observed with increasing activator concentrations, indicated cross-relaxation (CR) among the Ho{sup 3+} ions. Cross-relaxation rates were experimentally determined as a function of activator concentration and used to evaluate the values of the nearest-neighbor trapping rates X{sub 01} and to model the decays. It was observed that KGW, despite higher than in YAG maximum phonon energy of about 900 cm{sup -1}, is more efficient short-wavelength emitter than YAG. Examples of the excited-state absorption (ESA) and energy transfer (ET) mechanisms responsible for the upconverted, short-wavelength emissions were identified by analyzing fluorescence dynamics and possible energy resonances.

  1. Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser

    International Nuclear Information System (INIS)

    Malta, D A M P; De Andrade, M F; Costa, M M; Lizarelli, R F Z; Pelino, J E P

    2008-01-01

    The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm 2 . The adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm 2 . Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser

  2. Level structure of 154Ho

    Science.gov (United States)

    Moon, Chang-Bum; Komatsubara, Tetsuro; Furuno, Kohei

    2013-10-01

    The excited states of the odd-odd 154Ho nucleus have been studied by using in-beam γ-ray spectroscopy with the 141Pr (16O, 3n) 154Ho reaction at Elab=75 MeV. The beam was provided by the 12UD Pelletron accelerator at the University of Tsukuba. In this work, the complicated decay pattern of low energy transitions just above the T1/2=3.10 min isomer have been established. In addition, a number of new states and γ-ray transitions, especially those associated with energetically favored band termination, have been observed for the first time in 154Ho. A negative collective band and its signature partner built on the 11- level are interpreted as being based on the πh11/2⊗νi13/2 configuration. A positive band built on the 10+ level is based on the πh11/2⊗νh9/2 configuration while another positive band built on the 9+ level is being associated with the πh11/2⊗νf7/2 configuration. An energetically favored level Jπ=19- can be interpreted as being attributed to the πh11/2⊗νi13/2 configuration coupled to the 8+ state in neighboring core 152Dy, namely, a four-quasiparticle alignment based on the [πh11/2νi13/2]11-⊗[ν(h9/2f7/2)]8- configuration. Another energetically favored state at Jπ=27- is assigned the six-quasiparticle [π(h11/2)3]27/2-⊗[ν(f7/2h9/2i13/2)]27/2- configuration.

  3. AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)

    Science.gov (United States)

    An ELISA assay for heme oxygenase (HO-l ) Abstract A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...

  4. Lasing and thermal characteristics of Yb:YAG/YAG composite with atomic diffusion bonding

    Czech Academy of Sciences Publication Activity Database

    Nagisetty, Siva S.; Severová, Patricie; Miura, Taisuke; Smrž, Martin; Kon, H.; Uomoto, M.; Shimatsu, T.; Kawasaki, M.; Higashiguchi, T.; Endo, Akira; Mocek, Tomáš

    2017-01-01

    Roč. 14, č. 1 (2017), 1-6, č. článku 015001. ISSN 1612-2011 R&D Projects: GA MŠk LM2015086; GA MŠk LO1602 Institutional support: RVO:68378271 Keywords : composite Yb:YAG ceramic * atomic diffusion bonding * thermal effects Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 2.537, year: 2016

  5. Stimulated Raman adiabatic passage in Tm3+:YAG

    International Nuclear Information System (INIS)

    Alexander, A. L.; Lauro, R.; Louchet, A.; Chaneliere, T.; Le Goueet, J. L.

    2008-01-01

    We report on the experimental demonstration of stimulated Raman adiabatic passage in a Tm 3+ :YAG crystal. Tm 3+ :YAG is a promising material for use in quantum information processing applications, but as yet there are few experimental investigations of coherent Raman processes in this material. We investigate the effect of inhomogeneous broadening and Rabi frequency on the transfer efficiency and the width of the two-photon spectrum. Simulations of the complete Tm 3+ :YAG system are presented along with the corresponding experimental results

  6. Heat treatment of transparent Yb:YAG and YAG ceramics and its influence on laser performance

    Science.gov (United States)

    Fujioka, Kana; Mochida, Tetsuo; Fujimoto, Yasushi; Tokita, Shigeki; Kawanaka, Junji; Maruyama, Momoko; Sugiyama, Akira; Miyanaga, Noriaki

    2018-05-01

    Composite transparent ceramic materials are promising for improving the performance of high-average-power lasers. A combination of room-temperature bonding via surface treatment by a fast atom beam and diffusion bonding via heating, which effectively controls the ion diffusion distance near the interface, makes the laser materials suitable for a variety of oscillator/amplifier. During the heat treatment of yttrium aluminum garnet (YAG) ceramics, the Si ions in the solid solution of the sintering aid incorporated within the grains were seen to segregate at the grain boundary, resulting in an increase of scattering sites. The number density and size of the scattering sites strongly depended on the post-heating temperature rather than the heating time. Specifically, heating at 1300 °C did not affect the transmittance of the YAG ceramic, whereas both the size and number of scattering sites substantially increased with a heat treatment at 1400 °C. The laser oscillation experiment using cryogenically-cooled Yb:YAG ceramics exhibited heating temperature dependence of the slope efficiency owing to the increasing scattering loss.

  7. Luminescence properties in the visible of Dy:YAG/YAG planar waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Klimczak, M., E-mail: m.klimczak@elka.pw.edu.p [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Malinowski, M. [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); Sarnecki, J. [Institute of Electronic Materials Technology, Wolczynska 133, 01-919 Warsaw (Poland); Piramidowicz, R. [Institute of Microelectronics and Optoelectronics, Koszykowa 75, 00-662 Warsaw (Poland); Telekomunikacja Polska Research and Development Centre, Obrzezna 7, 02-691 Warsaw (Poland)

    2009-12-15

    In this work, we investigate visible emission properties of dysprosium-doped yttrium aluminum garnet (YAG) waveguides prepared by the liquid phase epitaxy (LPE) method, which allowed obtaining samples of activator concentrations ranging from 0.2 at% up to ca. 18 at%. This unique set of Dy:YAG/YAG waveguides has been carefully examined by means of highly resolved laser spectroscopy to explore the luminescence properties in the visible (yellow-blue) part of spectrum. In particular, the low-temperature absorption spectra have been recorded and analyzed, giving a more detailed information on energy levels' positions in these crystals. The concentration-dependant emission spectra and fluorescence dynamics profiles have been collected under direct excitation, enabling analysis of multi-ion processes responsible for concentration quenching. This, in turn, enabled optimization of activator concentration with respect to yellow emission efficiency. Additionally, the possible IR to visible up-conversion pathways have been discussed, giving a starting point for further investigations.

  8. Outcomes of Ahmed valve surgery for refractory glaucoma in Dhahran, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Tariq Alasbali

    2015-06-01

    Full Text Available AIM:To evaluate the outcomes of Ahmed glaucoma valve (AGV implantation surgery for refractory glaucoma.METHODS:This one-armed historical cohort study was conducted in 2011. Refractory glaucoma was defined as eyes with an intraocular pressure (IOP greater than 21 mm Hg with maximally tolerated glaucoma medications, failed surgeries, or both. For all eyes with refractory glaucoma that underwent AGV implantation, data were collected on IOP, the best corrected visual acuity (BCVA and glaucoma medications preoperatively and 4, 6, 12, 24 and 56wk postoperatively. Logarithm values of IOP were calculated and compared.RESULTS: The study group was comprised of 30 patients (30 eyes, 16 males and 14 females with refractory glaucoma. Mean preoperative IOP was 39.3±13.8 mm Hg. Postoperative mean IOP was 15.7±7.1 mm Hg, 19.6±12.8 mm Hg and 13.9±14.2 mm Hg at 12, 24 and 56wk respectively. BCVA was ≥ 6/60 in 11 eyes preoperatively, and five eyes had BCVA≥6/60 at 56wk postoperatively. Preoperatively, more than four medications were used to treat glaucoma in 21 eyes. At 12wk postoperatively, no medications were required to control IOP in 20 eyes. At 56wk postoperatively, at least one medication was required to control IOP in 10 eyes. Over the entire follow up period, four eyes were treated with yttrium aluminium garnet (YAG laser and 14 eyes required a second surgery. The AGV was removed in four eyes.CONCLUSION: AGV implantation reduced IOP and the number of medications required to control refractory glaucoma. However, there was a higher risk of decreased vision. Long-term follow up and prompt intervention are recommended.

  9. Facile synthesis of silicon carbide-titanium dioxide semiconducting nanocomposite using pulsed laser ablation technique and its performance in photovoltaic dye sensitized solar cell and photocatalytic water purification

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, M.A., E-mail: magondal@kfupm.edu.sa [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Ilyas, A.M. [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Baig, Umair [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Center of Excellence for Scientific Research Collaboration with MIT, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2016-08-15

    Highlights: • SiC–TiO{sub 2} semiconducting nanocomposites synthesized by nanosecond PLAL technique. • Synthesized nanocomposites were morphologically and optically characterized. • Nanocomposites were applied for the photocatalytic degradation of toxic organic dye. • Photovoltaic performance was investigated in dye sensitized solar cell. - Abstract: Separation of photo-generated charge carriers (electron and holes) is a major approach to improve the photovoltaic and photocatalytic performance of metal oxide semiconductors. For harsh environment like high temperature applications, ceramic like silicon carbide is very prominent. In this work, 10%, 20% and 40% by weight of pre-oxidized silicon carbide was coupled with titanium dioxide (TiO{sub 2}) to form nanocomposite semiconductor via elegant pulsed laser ablation in liquid technique using second harmonic 532 nm wavelength of neodymium-doped yttrium aluminium garnet (Nd-YAG) laser. In addition, the effect of silicon carbide concentration on the performance of silicon carbide-titanium dioxide nanocomposite as photo-anode in dye sensitized solar cell and as photocatalyst in photodegradation of methyl orange dye in water was also studied. The result obtained shows that photo-conversion efficiency of the dye sensitized solar cell was improved from 0.6% to 1.65% and the percentage of methyl orange dye removed was enhanced from 22% to 77% at 24 min under ultraviolet–visible solar spectrum in the nanocomposite with 10% weight of silicon carbide. This remarkable performance enhancement could be due to the improvement in electron transfer phenomenon by the presence of silicon carbide on titanium dioxide.

  10. Irrigant flow during photon-induced photoacoustic streaming (PIPS) using Particle Image Velocimetry (PIV).

    Science.gov (United States)

    Koch, Jon D; Jaramillo, David E; DiVito, Enrico; Peters, Ove A

    2016-03-01

    This study aimed to compare fluid movements generated from photon-induced photoacoustic streaming (PIPS) and passive ultrasonic irrigation (PUI). Particle Image Velocimetry (PIV) was performed using 6-μm melamine spheres in water. Measurement areas were 3-mm-long sections of the canal in the coronal, midroot and apical regions for PIPS (erbium/yttrium-aluminium garnet (Er:YAG) laser set at 15 Hz with 20 mJ), or passive ultrasonic irrigation (PUI, non-cutting insert at 30% unit power) was performed in simulated root canals prepared to an apical size #30/0.04 taper. Fluid movement was analysed directly subjacent to the apical ends of ultrasonic insert or fiber optic tips as well as at midroot and apically. During PUI, measured average velocities were around 0.03 m/s in the immediate vicinity of the sides and tip of the ultrasonic file. Speeds decayed to non-measureable values at a distance of about 2 mm from the sides and tip. During PIPS, typical average speeds were about ten times higher than those measured for PUI, and they were measured throughout the length of the canal, at distances up to 20 mm away. PIPS caused higher average fluid speeds when compared to PUI, both close and distant from the instrument. The findings of this study could be relevant to the debriding and disinfecting stage of endodontic therapy. Irrigation enhancement beyond needle irrigation is relevant to more effectively eradicate microorganisms from root canal systems. PIPS may be an alternative approach due to its ability to create high streaming velocities further away from the activation source compared to ultrasonic activation.

  11. Pulsed Nd-YAG laser in endodontics

    Science.gov (United States)

    Ragot-Roy, Brigitte; Severin, Claude; Maquin, Michel

    1994-12-01

    The purpose of this study was to establish an operative method in endodontics. The effect of a pulsed Nd:YAG laser on root canal dentin has been examined with a scanning electron microscope. Our first experimentation was to observe the impacts carried out perpendicularly to root canal surface with a 200 micrometers fiber optic in the presence of dye. Secondarily, the optical fiber was used as an endodontic instrument with black dye. The irradiation was performed after root canal preparation (15/100 file or 40/100 file) or directly into the canal. Adverse effects are observed. The results show that laser irradiation on root canal dentin surfaces induces a nonhomogeneous modified dentin layer, melted and resolidified dentin closed partially dentinal tubules. The removal of debris is not efficient enough. The laser treatment seems to be indicated only for endodontic and periapical spaces sterilization after conventional root canal preparation.

  12. The bactericidal effect of a Genius (R) Nd : YAG laser

    NARCIS (Netherlands)

    Kranendonk, A.A.; Reijden, W.A. van der; Winkelhoff, A.J. van; Weijden, G.A. van der

    PURPOSE: To evaluate the 'in vitro' bactericidal effect of the Nd:YAG laser (Genius, MØlsgaard Dental, Copenhagen, Denmark) on six periodontal pathogens. METHODS: Suspensions of six different periodontal pathogens (Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Prevotella

  13. Self-mode-locked Nd3+:YAG laser

    International Nuclear Information System (INIS)

    Komarov, A K; Komarov, K P; Kuch'yanov, Aleksandr S

    2003-01-01

    Self-mode-locking was observed in a Nd 3+ :YAG laser with a negative feedback without introducing any nonlinear elements into the laser cavity. The laser generates during pumping 300 - 500-ps single pulses on an axial period. (lasers)

  14. Neodymium-YAG laser vitreolysis in sickle cell retinopathy

    Energy Technology Data Exchange (ETDEWEB)

    Hrisomalos, N.F.; Jampol, L.M.; Moriarty, B.J.; Serjeant, G.; Acheson, R.; Goldberg, M.F.

    1987-08-01

    Six patients with proliferative sickle cell retinopathy and vitreous bands were treated with the neodymium-YAG (Nd-YAG) laser to accomplish lysis of avascular traction bands or to clear the media in front of the macula. Transection of bands was possible in five of the six cases but in two of these the effect was only partial. Three cases were satisfactorily treated with the Nd-YAG laser application alone, two eventually required conventional vitreoretinal surgery, and one patient's condition stabilized despite failure of the treatment. Complications from the treatment occurred in three cases and included subretinal (choroidal) hemorrhage, preretinal hemorrhage, microperforation of a retinal vein, and focal areas of damage to the retinal pigment epithelium. Neodymium-YAG vitreolysis may be a useful modality in carefully selected patients with proliferative sickle cell retinopathy, but potentially sight-threatening complications may occur.

  15. [Nd-YAG laser photocoagulation of scrotal sebaceous cysts].

    Science.gov (United States)

    Franco de Castro, A; Truhán, D; Carretero González, P; Alcover García, J

    2002-02-01

    Scrotum's sebaceous cyst is an usual pathology, not life threatening, but susceptible of infection, producing abscess with their associated cosmetic and psychological disturbance. The classical management is the complete excision, under local anaesthesia, to prevent its recidive. Until today, the use of de Nd-YAG laser for the management of the scrotum's sebaceous cysts as not been reported. We report a case of a young man with several scrotum's sebaceous cysts, treated successfully with the use of a Nd-YAG laser.

  16. Reaction rate constant of HO2+O3 measured by detecting HO2 from photofragment fluorescence

    Science.gov (United States)

    Manzanares, E. R.; Suto, Masako; Lee, Long C.; Coffey, Dewitt, Jr.

    1986-01-01

    A room-temperature discharge-flow system investigation of the rate constant for the reaction 'HO2 + O3 yields OH + 2O2' has detected HO2 through the OH(A-X) fluorescence produced by photodissociative excitation of HO2 at 147 nm. A reaction rate constant of 1.9 + or - 0.3 x 10 to the -15th cu cm/molecule per sec is obtained from first-order decay of HO2 in excess O3; this agrees well with published data.

  17. Analysis of erythema after Er:YAG laser skin resurfacing.

    Science.gov (United States)

    Ko, Na Young; Ahn, Hyo-Hyun; Kim, Soo-Nam; Kye, Young-Chul

    2007-11-01

    Postoperative erythema can be expected to occur in every patient after laser resurfacing, and pigmentary disturbances may be related to the intensity and the duration of erythema. This study was undertaken to assess the clinical features of erythema, the factors that influence its duration, and the relation between the duration of erythema and the incidence of hyperpigmentation and hypopigmentation in skin of Asian persons after Er:YAG laser resurfacing. A total of 218 patients (skin phototypes III to V) were recruited and treated with a short-pulsed Er:YAG laser, a variable-pulsed Er:YAG laser, or a dual-mode Er:YAG laser for skin resurfacing. Clinical assessments were performed retrospectively using medical charts and serial photographs. Postoperative erythema was observed in all patients after Er:YAG laser resurfacing with a mean duration of 4.72 months. In 98.2% of patients, erythema faded completely within 12 months. Postinflammatory hyperpigmentation was observed in 38.1% of patients after Er:YAG laser resurfacing. Skin phototype, level of ablation, and depth of thermal damage caused by a long-pulsed laser appear to be important factors that affect the duration of erythema. Moreover, prolonged erythema was related to the risk of postinflammatory hyperpigmentation.

  18. Suppression of parasitic oscillations in a core-doped ceramic Nd:YAG laser by Sm:YAG cladding.

    Science.gov (United States)

    Huss, Rafael; Wilhelm, Ralf; Kolleck, Christian; Neumann, Jörg; Kracht, Dietmar

    2010-06-07

    The onset of parasitic oscillations limits the extraction efficiency and therefore energy scaling of Q-switched lasers. A solid-state laser was end pumped with a fiber-coupled diode laser and operated in q-cw as well as in passively Q-switched operation. For Q-switched operation, we demonstrate the suppression of parasitic oscillations in a core-doped ceramic Nd:YAG laser by Sm:YAG cladding.

  19. Efficacy of long pulse Nd:YAG laser versus fractional Er:YAG laser in the treatment of hand wrinkles.

    Science.gov (United States)

    Robati, Reza M; Asadi, Elmira; Shafiee, Anoosh; Namazi, Nastaran; Talebi, Atefeh

    2018-04-01

    There are different modalities for hand rejuvenation. Fractional Er:YAG laser and long pulse Nd:YAG laser were introduced for treating hand wrinkles. We plan to compare fractional Er:YAG laser and long pulse Nd:YAG laser in a randomized controlled double-blind design with multiple sessions and larger sample size in comparison with previous studies. Thirty-three participants with hand wrinkles entered this study. They were randomly allocated to undergo three monthly laser treatments on each hand, one with a fractional Er:YAG laser and the other with a long pulse Nd:YAG laser. The evaluations included assessment of clinical improvement determined by two independent dermatologists not enrolled in the treatment along with measuring skin biomechanical property of hands using a sensitive biometrologic device with the assessment of cutaneous resonance running time (CRRT). Moreover, potential side effects and patients' satisfaction have been documented at baseline, 1 month after each treatment, and 3 months after the final treatment session. Clinical evaluation revealed both modalities significantly reduce hand wrinkles (p value lasers. Mean CRRT values also decreased significantly after the laser treatment compared to those of the baseline in both laser groups. There was no serious persistent side effect after both laser treatments. Both fractional Er:YAG and long pulse Nd:YAG lasers show substantial clinical improvement of hand skin wrinkles with no serious side effects. However, combination treatment by these lasers along with the other modalities such as fat transfer could lead to better outcomes in hand rejuvenation. IRCT2016032020468N4.

  20. Hybrid Pulsed Nd:YAG Laser

    Science.gov (United States)

    Miller, Sawyer; Trujillo, Skyler; Fort Lewis College Laser Group Team

    This work concerns the novel design of an inexpensive pulsed Nd:YAG laser, consisting of a hybrid Kerr Mode Lock (KLM) and Q-switch pulse. The two pulse generation systems work independently, non simultaneously of each other, thus generating the ability for the user to easily switch between ultra-short pulse widths or large energy density pulses. Traditionally, SF57 glass has been used as the Kerr medium. In this work, novel Kerr mode-locking mediums are being investigated including: tellurite compound glass (TeO2), carbon disulfide (CS2), and chalcogenide glass. These materials have a nonlinear index of refraction orders of magnitude,(n2), larger than SF57 glass. The Q-switched pulse will utilize a Pockels cell. As the two pulse generation systems cannot be operated simultaneously, the Pockels cell and Kerr medium are attached to kinematic mounts, allowing for quick interchange between systems. Pulse widths and repetition rates will vary between the two systems. A goal of 100 picosecond pulse widths are desired for the mode-locked system. A goal of 10 nanosecond pulse widths are desired for the Q-switch system, with a desired repetition rate of 50 Hz. As designed, the laser will be useful in imaging applications.

  1. Estimation of human absorbed dose for (166)Ho-PAM: comparison with (166)Ho-DOTMP and (166)Ho-TTHMP.

    Science.gov (United States)

    Vaez-Tehrani, Mahdokht; Zolghadri, Samaneh; Yousefnia, Hassan; Afarideh, Hossein

    2016-10-01

    In this study, the human absorbed dose of holmium-166 ((166)Ho)-pamidronate (PAM) as a potential agent for the management of multiple myeloma was estimated. (166)Ho-PAM complex was prepared at optimized conditions and injected into the rats. The equivalent and effective absorbed doses to human organs after injection of the complex were estimated by radiation-absorbed dose assessment resource and methods proposed by Sparks et al based on rat data. The red marrow to other organ absorbed dose ratios were compared with these data for (166)Ho-DOTMP, as the only clinically used (166)Ho bone marrow ablative agent, and (166)Ho-TTHMP. The highest absorbed dose amounts are observed in the bone surface and bone marrow with 1.11 and 0.903 mGy MBq(-1), respectively. Most other organs would receive approximately insignificant absorbed dose. While (166)Ho-PAM demonstrated a higher red marrow to total body absorbed dose ratio than (166)Ho-1,4,7,10-tetraazacyclo dodecane-1,4,7,10 tetra ethylene phosphonic acid (DOTMP) and (166)Ho-triethylene tetramine hexa (methylene phosphonic acid) (TTHMP), the red marrow to most organ absorbed dose ratios for (166)Ho-TTHMP and (166)Ho-PAM are much higher than the ratios for (166)Ho-DOTMP. The result showed that (166)Ho-PAM has significant characteristics than (166)Ho-DOTMP and therefore, this complex can be considered as a good agent for bone marrow ablative therapy. In this work, two separate points have been investigated: (1) human absorbed dose of (166)Ho-PAM, as a potential bone marrow ablative agent, has been estimated; and (2) the complex has been compared with (166)Ho-DOTMP, as the only clinically used bone marrow ablative radiopharmaceutical, showing significant characteristics.

  2. Compact corner-pumped Nd:YAG/YAG composite slab 1319 nm/1338 nm laser

    International Nuclear Information System (INIS)

    Liu, H; Gong, M; Wushouer, X; Gao, S

    2010-01-01

    A corner-pumped type is a new pumping type in the diode-pumped solid-state lasers, which has the advantages of high pump efficiency and favorable pump uniformity. A corner-pumped Nd:YAG/YAG composite slab continuous-wave 1319 nm/1338 nm dual-wavelength laser is first demonstrated in this paper. When the cavity length is 25 mm, the maximal output power is up to 7.62 W with a slope efficiency of 16.6% and an optical-to-optical conversion efficiency of 17%. The corresponding spectral line widths of 1319 nm laser and 1338 nm laser are 0.11 and 0.1 nm, respectively. The short-term instability of the output power is better than 1% when the pumping power is 39.5 W. The experimental results show that a corner-pumped type is a kind of feasible schedules in the design of diode-pumped solid-state 1.3 μm lasers with low or medium output powers

  3. Highly efficient solar-pumped Nd:YAG laser.

    Science.gov (United States)

    Liang, Dawei; Almeida, Joana

    2011-12-19

    The recent progress in solar-pumped laser with Fresnel lens and Cr:Nd:YAG ceramic medium has revitalized solar laser researches, revealing a promising future for renewable reduction of magnesium from magnesium oxide. Here we show a big advance in solar laser collection efficiency by utilizing an economical Fresnel lens and a most widely used Nd:YAG single-crystal rod. The incoming solar radiation from the sun is focused by a 0.9 m diameter Fresnel lens. A dielectric totally internally reflecting secondary concentrator is employed to couple the concentrated solar radiation from the focal zone to a 4 mm diameter Nd:YAG rod within a conical pumping cavity. 12.3 W cw laser power is produced, corresponding to 19.3 W/m(2) collection efficiency, which is 2.9 times larger than the previous results with Nd:YAG single-crystal medium. Record-high slope efficiency of 3.9% is also registered. Laser beam quality is considerably improved by pumping a 3 mm diameter Nd:YAG rod.

  4. DEBONDING OF CERAMIC BRACKETS BY ER:YAG LASER

    Directory of Open Access Journals (Sweden)

    Fidan ALAKUŞ-SABUNCUOĞLU

    2016-04-01

    Full Text Available Purpose: The objective of the present study is to evaluate the effects of Er:YAG laser debonding of ceramic brackets on the bond strength and the amount of adhesive resin remnant. Materials and Methods: Twenty human mandibular incisors were randomly divided into two groups of 10 and polycrystalline ceramic brackets (Transcend series 6000, 3M Unitek, Monrovia, CA, USA were bonded on enamel surfaces. Group 1 was the control group in which no laser application was performed prior to the shear bond strength (SBS testing. In Group 2, Er:YAG was applied in 3W power for 6 seconds using the scanning method. The brackets were tested for SBS with an Instron universal testing machine and results were expressed in megapascals (MPa. The amount of adhesive remnant was evaluated with Adhesive Remnant Index (ARI. One-way analysis of variance and Tukey’s post-hoc tests were used for statistical analysis. Results: Mean ± standard deviation of SBS values in the control group was 13.42 ±1.23 MPa and 8.47 ±0.71 MPa in the Er:YAG group and this difference was statistically significant (p<0.05. The evaluation of ARI scores demonstrated more adhesive was left on the enamel surface with Er:YAG group. Conclusion: 3W power Er:YAG laser application with the scanning method to polycrystalline ceramic brackets demonstrated lower bond strengths and higher ARI scores during the debonding procedure.

  5. Conversion of homothallic yeast to heterothallism trough HO gene disruption

    CSIR Research Space (South Africa)

    Van Zyl, WH

    1993-04-01

    Full Text Available A simple method was developed for the conversion of homothallic Saccharomyces cerevisiae yeaststrains to heterothallism through HO gene disruption. An integrative ho:: neo disrupted allele was constructed by cloning a dominant selectable marker...

  6. Evaluation in vitro of effects of Er:YAG and Nd:YAG lasers irradiation on root canal wall, by stereoscopy, scanning electron micrography and thermographic camera

    International Nuclear Information System (INIS)

    Goya, Claudia

    2001-01-01

    This study was carried out to evaluate in vitro the effects of Nd:YAG laser and Er:YAG laser irradiation in the root canal wall by SEM, evaluating the apical leakage and the temperature changes during the laser irradiation. Seventy four extracted human teeth were used, they were instrumented and divided into seven groups of 10 teeth each. The teeth were evaluated through stereoscopy, by SEM, and with the thermographic camera. The Nd:YAG laser irradiation parameters were 100 mJ/p, 15 Hz, and Er:YAG laser were 160 mJ/p and 10 Hz, the irradiation was 4 times at 2 mm/sec speed, with 20 sec interval. The apical leakage was not observed in the teeth irradiated by Nd:YAG laser alone or in association with Er:YAG laser. However in the teeth irradiated only by the Er:YAG laser we observed a little leakage. By SEM observation the Nd:YAG laser irradiation showed melting and recrystallization in the dentin surface closing dentinal tubules, and in the samples irradiated by Er:Y AG laser a clean surface, opened dentinal tubules, and the combination by two lasers, showed melting covering some dentinal tubules The thermographic study found the temperature increase was not more than 6 deg C. This study showed the safety parameters applications of Er:YAG laser in association with Nd:YAG laser in root canal treatment, in order to not cause thermal damages to the periodontal tissues. (author)

  7. Nd:YAG Laser Firmware Design under RTOS Operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B. G.; Kim, W. Y.; Park, G. R.; Moon, D. S.; Hong, J. H.; Kim, H. J.; Cho, J. S. [Pusan National University (Korea)

    2000-07-01

    A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate. This system is controlled by microprocessor and allows to replace an expensive condenser for high frequency to cheap one of low frequency. In addition, The microcontroller monitors the flow of cooling water, short circuit, and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now. (author). 8 refs., 6 figs.

  8. Yb:YAG Lasers for Space Based Remote Sensing

    Science.gov (United States)

    Ewing, J.J.; Fan, T. Y.

    1998-01-01

    Diode pumped solid state lasers will play a prominent role in future remote sensing missions because of their intrinsic high efficiency and low mass. Applications including altimetry, cloud and aerosol measurement, wind velocity measurement by both coherent and incoherent methods, and species measurements, with appropriate frequency converters, all will benefit from a diode pumped primary laser. To date the "gold standard" diode pumped Nd laser has been the laser of choice for most of these concepts. This paper discusses an alternate 1 micron laser, the YB:YAG laser, and its potential relevance for lidar applications. Conceptual design analysis and, to the extent possible at the time of the conference, preliminary experimental data on the performance of a bread board YB:YAG oscillator will be presented. The paper centers on application of YB:YAG for altimetry, but extension to other applications will be discussed.

  9. Growth of single-crystal YAG fiber optics.

    Science.gov (United States)

    Nie, Craig D; Bera, Subhabrata; Harrington, James A

    2016-07-11

    Single-crystal YAG (Y3Al5O12) fibers have been grown by the laser heated pedestal growth technique with losses as low as 0.3 dB/m at 1.06 μm. These YAG fibers are as long as about 60 cm with diameters around 330 μm. The early fibers were grown from unoriented YAG seed fibers and these fibers exhibited facet steps or ridges on the surface of the fiber. However, recently we have grown fibers using an oriented seed to grow step-free fibers. Scattering losses made on the fibers indicate that the scattering losses are equal to about 30% of the total loss.

  10. Novostavba rodinného domu

    OpenAIRE

    Manduch, Dávid

    2017-01-01

    Jedná sa o samostatne stojaci, dvojpodlažný, nepodpivničený rodinný dom zastrešený plochou vegetačnou strechou v obci Šalgovce. Súčasťou rodinného domu sú dve drevené terasy. Vstupná terasa sa nachádza pred hlavným vstupom do objektu a terasa pre relax je prístupná z obytnej miestnosti s kuchynským kútom. Z tejto terasy je priamy prístup do záhrady. Hlavný stavebný materiál rodinného domu sú stenové panely EcoCocon - kombinácia dreveného rámu a slamenej výplne Garáž je samostatne stojaci jedn...

  11. Next generation Er:YAG fractional ablative laser

    Science.gov (United States)

    Heinrich, A.; Vizhanyo, A.; Krammer, P.; Summer, S.; Gross, S.; Bragagna, T.; Böhler, C.

    2011-03-01

    Pantec Biosolutions AG presents a portable fractional ablative laser system based on a miniaturized diode pumped Er:YAG laser. The system can operate at repetition rates up to 500 Hz and has an incorporated beam deflection unit. It is smaller, lighter and cost efficient compared to systems based on lamp pumped Er:YAG lasers and incorporates a skin layer detection to guarantee precise control of the microporation process. The pulse parameters enable a variety of applications in dermatology and in general medicine, as demonstrated by first results on transdermal drug delivery of FSH (follicle stimulating hormone).

  12. CW Yb:YAG LASER FOR PORTABLE MEASURING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. M. Ivashko

    2014-01-01

    Full Text Available The theoretical and experimental results of longitudinally continuous-wave diode-pumped Yb:Y3Al5O12 (YAG laser performance for compact field-condition measuring systems were demonstrated. Optimization of laser setup in terms of operation condition in the range of -40 ˚С – +65 ˚С without active thermal stabilization was carried out. Using Yb (10 ат.%:YAG crystal with the length of 3 mm the maximal output power more than 2 W was obtained in the whole of temperature range.

  13. Laser beam diagnostics for kilowatt power pulsed YAG laser

    International Nuclear Information System (INIS)

    Liu, Yi; Leong, Keng H.

    1992-01-01

    There is a growing need for high power YAG laser beam diagnostics with the recent introduction of such lasers in laser material processing. In this paper, we will describe the use of a commercially available laser beam analyzer (Prometec) to profile the laser beam from a 1600 W pulsed Nd:YAG laser that has a 1 mm fiber optic beam delivery system. The selection of laser pulse frequency and pulse width for the measurement is discussed. Laser beam propagation parameters by various optical components such as fibers and lenses can be determined from measurements using this device. The importance of such measurements will be discussed

  14. Spin Waves in Ho2Co17

    DEFF Research Database (Denmark)

    Clausen, Kurt Nørgaard; Lebech, Bente

    1980-01-01

    Spin wave excitations in a single crystal of Ho2Co17 have been studied at 4.8 and 78 K. The results are discussed in terms of a linear spin wave model. At 78 K both ground state and excited state spin waves are observed.......Spin wave excitations in a single crystal of Ho2Co17 have been studied at 4.8 and 78 K. The results are discussed in terms of a linear spin wave model. At 78 K both ground state and excited state spin waves are observed....

  15. Optical properties and laser oscillations of highly neodymium-doped YAG ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Shoji, Ichiro; Kurimura, Sunao; Sato, Yoichi; Taira, Takunori [Laser Research Center, Institute for Molecular Science, Okazaki, Aichi (Japan); Ikesue, Akio [Japan Fine Ceramics Center, Nagoya, Aichi (Japan); Yoshida, Kunio [Institute of Laser Engineering, Osaka Institute of Technology, Osaka (Japan)

    2000-03-01

    Diode-pumped microchip laser oscillation of highly Nd{sup 3+}-doped polycrystalline YAG ceramics has been succeeded. It is found that the loss of a 2.4 at. % neodymium-doped ceramic YAG is as low as that of a 0.9 at. % Nd:YAG single crystal. From a 4.8 at. % Nd:YAG ceramic microchip, 2.3 times higher laser output power is obtained than that from a 0.9 at. % Nd:YAG single crystal microchip. (author)

  16. Optical properties and laser oscillations of highly neodymium-doped YAG ceramics

    International Nuclear Information System (INIS)

    Shoji, Ichiro; Kurimura, Sunao; Sato, Yoichi; Taira, Takunori; Ikesue, Akio; Yoshida, Kunio

    2000-01-01

    Diode-pumped microchip laser oscillation of highly Nd 3+ -doped polycrystalline YAG ceramics has been succeeded. It is found that the loss of a 2.4 at. % neodymium-doped ceramic YAG is as low as that of a 0.9 at. % Nd:YAG single crystal. From a 4.8 at. % Nd:YAG ceramic microchip, 2.3 times higher laser output power is obtained than that from a 0.9 at. % Nd:YAG single crystal microchip. (author)

  17. Changes of retinal light sensitivity after YAG-laser capsulotomy

    International Nuclear Information System (INIS)

    Pahor, D.; Gracner, B.

    2003-01-01

    The aim of this prospective study was to investigate the changes of retinal light sensitivity of central visual field in patients with posterior capsule opacification (PCO) after YAG-laser capsulotomy. Our study includes 18 eyes ( 18 patients) with PCO after phacoemulsification and intraocular lens implantation. In all patients YAG-laser capsulotomy was performed. In all patients, a threshold visual field analysis was carried out with the C 30-2 program of the automated Humphrey Field Analyzer before and one month after the procedure. In all patients a significant improvement of visual acuity was observed one month after capsulotomy (p 0.00004). One month after YAG-laser treatment, a significant improvement of retinal light sensitivity in the central visual field was also observed. The average MD (mean deviation) before the procedure was -6.88 db (±3.9, max. -11.7, min. 2.17) and after the procedure --4.58 db (±4.37, max. -10.87, min. +0.51). The improvement in MD was statistically significant (p = 0.00475). No correlation was established between the improvement of retinal light sensitivity and patient age or the size of capsulotomy. Our study shows that the improvement of retinal light sensitivity is significant after YAG-laser capsulotomy and does not depend on patient age or capsulotomy size. (author)

  18. Tunable, diode side-pumped Er:YAG laser

    Science.gov (United States)

    Hamilton, C.E.; Furu, L.H.

    1997-04-22

    A discrete-element Er:YAG laser, side pumped by a 220 Watt peak-power InGaAs diode array, generates >500 mWatts at 2.94 {micro}m, and is tunable over a 6 nm range near about 2.936 {micro}m. The oscillator is a plano-concave resonator consisting of a concave high reflector, a flat output coupler, a Er:YAG crystal and a YAG intracavity etalon, which serves as the tuning element. The cavity length is variable from 3 cm to 4 cm. The oscillator uses total internal reflection in the Er:YAG crystal to allow efficient coupling of the diode emission into the resonating modes of the oscillator. With the tuning element removed, the oscillator produces up to 1.3 Watts of average power at 2.94 {micro}m. The duty factor of the laser is 6.5% and the repetition rate is variable up to 1 kHz. This laser is useful for tuning to an atmospheric transmission window at 2.935 {micro}m (air wavelength). The laser is also useful as a spectroscopic tool because it can access several infrared water vapor transitions, as well as transitions in organic compounds. Other uses include medical applications (e.g., for tissue ablation and uses with fiber optic laser scalpels) and as part of industrial effluent monitoring systems. 4 figs.

  19. Application of YAG laser cladding to the flange seating surface

    International Nuclear Information System (INIS)

    Nakanishi, Koki; Ninomiya, Kazuyuki; Nezaki, Koji

    1999-01-01

    Stainless cladding on carbon steel is usually conducted by shielded metal arc welding (SMAW) or gas tungsten arc welding (GTAW). YAG ( Yttrium-Aluminum-Garnet) laser welding is superior to these methods of welding in the following respects : (1) The heat affected zone (HAZ) is narrower and there is less distortion. (2) YAG laser cladding has the required chemical compositions, even with possibly fewer welding layers under controlled dilution. (3) Greater welding speed. YAG laser cladding application to vessel flange seating surfaces was examined in this study and the results are discussed. The following objectives were carried out : (1) Determination of welding conditions for satisfactory cladding layers and (2) whether cladding would be adequately possible at a cornered section of a stair-like plate, assuming actual flange shape. (3) Measurement of welding distortion and heat affected zone in carbon steel. The welding conditions for producing no-crack deposit with low dilution in carbon steel were clarified and welding by which cladding at cornered section would be possible was achieved. welding distortion by YAG laser was found less than with GTAW and HAZ made by first layer welding could be tempered appropriately by second layer welding. (author)

  20. Nd-YAG laser welding of bare and galvanised steels

    International Nuclear Information System (INIS)

    Kennedy, S.C.; Norris, I.M.

    1989-01-01

    Until recently, one of the problems that has held back the introduction of lasers into car body fabrication has been the difficulty of integrating the lasers with robots. Nd-YAG laser beams can be transmitted through fibre optics which, as well as being considerably easier to manipulate than a mirror system, can be mounted on more lightweight accurate robots. Although previously only available at low powers, recent developments in Nd-YAG laser technology mean that lasers of up to 1kW average power will soon be available, coupled to a fibre optic beam delivery system. The increasing usage of zinc coated steels in vehicle bodies has led to welding problems using conventional resistance welding as well as CO 2 laser welding. The use of Nd-YAG lasers may be able to overcome these problems. This paper outlines work carried out at The Welding Institute on a prototype Lumonics 800W pulsed Nd-YAG laser to investigate its welding characteristics on bare and zinc coated car body steels

  1. Neodymium:YAG laser cutting of intraocular lens haptics.

    Science.gov (United States)

    Gorn, R A; Steinert, R F

    1985-11-01

    Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.

  2. Pulsed Nd:YAG laser beam drilling: A review

    Science.gov (United States)

    Gautam, Girish Dutt; Pandey, Arun Kumar

    2018-03-01

    Laser beam drilling (LBD) is one of non contact type unconventional machining process that are employed in machining of stiff and high-strength materials, high strength temperature resistance materials such as; metal alloys, ceramics, composites and superalloys. Most of these materials are difficult-to-machine by using conventional machining methods. Also, the complex and precise holes may not be obtained by using the conventional machining processes which may be obtained by using unconventional machining processes. The laser beam drilling in one of the most important unconventional machining process that may be used for the machining of these materials with satisfactorily. In this paper, the attention is focused on the experimental and theoretical investigations on the pulsed Nd:YAG laser drilling of different categories of materials such as ferrous materials, non-ferrous materials, superalloys, composites and Ceramics. Moreover, the review has been emphasized by the use of pulsed Nd:YAG laser drilling of different materials in order to enhance productivity of this process without adverse effects on the drilled holes quality characteristics. Finally, the review is concluded with the possible scope in the area of pulsed Nd:YAG laser drilling. This review work may be very useful to the subsequent researchers in order to give an insight in the area of pulsed Nd:YAG laser drilling of different materials and research gaps available in this area.

  3. Preparation and properties of Pr /Ce :YAG phosphors using ...

    Indian Academy of Sciences (India)

    2015-09-01

    Sep 1, 2015 ... [3] transparent ceramics for high power solid-state lasers and Ce:YAG ... and CO2−. 3 . ... be controlled to guarantee that all the metal ions are simul- taneously .... of hydrogen bonding interaction can lead to more serious.

  4. A Mid-IR Optical Parametric Oscillator Pumped by an Actively Q-Switched Ho:YAG Ceramic Laser

    Science.gov (United States)

    Yuan, Jin-He; Duan, Xiao-Ming; Yao, Bao-Quan; Li, Jiang; Shen, Ying-Jie; Cui, Zheng; Dai, Tong-Yu; Pan, Yu-Bai

    2015-08-01

    Not Available Supported by the National Natural Science Foundation of China under Grant Nos 61308009, 61405047 and 50990301, the Fundamental Research Funds for the Central Universities under Grant Nos HIT.NSRIF.2014044 and HIT.NSRIF.2015042, and the Science Fund for Outstanding Youths of Heilongjiang Province under Grant No JQ201310.

  5. Saigon-Ho Chi Minh City

    NARCIS (Netherlands)

    Nguyen, T.B.; Samsura, D.A.A.; Krabben, E. van der; Le, A.D.; Le, A.-D.

    2016-01-01

    Ho Chi Minh City (HCMC) has existed for over three centuries and has developed into the financial capital and most important economic hub of Vietnam. This profile outlines the history of HCMC's development and its impact on current conditions and physical structure of the city. The paper analyzes

  6. [Experimental results of erbium:YAG laser vitrectomy].

    Science.gov (United States)

    Mrochen, M; Petersen, H; Wüllner, C; Seiler, T

    1998-01-01

    Vitrectomy performed by conventional guillotine devices includes the risk of mechanical damage to retina as well as other ocular structures. The present study aims to investigate the efficacy of the Er:YAG laser for vitreous liquefaction. Vitreous liquefaction by means of Er:YAG laser pulses was performed using a special handpiece. The output of an Er:YAG laser operating at 2.94 microns was coupled into a ZrF optical fibre (length 2 m) which ended inside a cavity located at the quartz tip (diameter 320 microns) of the handpiece where tissue ablation took place. The viscosity of the liquefied vitreous was determined by rotation viscosimetry and compared to liquefied vitreous obtained by mechanical vitrectomy. In addition, the aspiration flow (ml/min) was correlated to the repetition/cutting rate of the laser and the cutter. The temperature rise at the handpiece was recorded with a micro thermocouple. The cutting threshold was determined to 5 mJ +/- 3 mJ at a pulse duration of 200 microseconds. The viscosity of the vitreous liquefied with the Er:YAG laser was 31 +/- 10 mPa s which is similar to the results of mechanical vitrectomy (42 +/- 19 mPa s) but significant less than that of normal vitreous (880 +/- 280 mPa s). The aspiration of the laser handpiece in dependence to the repetition rate increases linear up to 2.6 ml/min at 30 Hz. The temperature increase at the handpiece was < 1 K under vitrectomy conditions (aspiration and irrigation) with an averaged laser power of 0.3 W (10 mJ at 30 Hz). The decreased vacuum forces used by the laser vitrectomy system may result in less mechanical stress to the retina as well as intravitreal structures which may be attached to it. An Er:YAG laser vitrectomy system may offer the potential of fewer complications during vitrectomy.

  7. FT-Raman spectroscopic characterization of enamel surfaces irradiated with Nd:YAG and Er:YAG lasers

    Directory of Open Access Journals (Sweden)

    Sima Shahabi

    2016-12-01

    Full Text Available Background. Despite recent advances in dental caries prevention, caries is common and remains a serious health problem. Laser irradiation is one of the most common methods in preventive measures in recent years. Raman spectroscopy technique is utilized to study the microcrystalline structure of dental enamel. In this study, FT-Raman spectroscopy was used to evaluate chemical changes in enamel structure irradiated with Nd:YAG and Er:YAG lasers. Methods. We used 15 freshly-extracted, non-carious, human molars that were treated as follows: No treatment was carried out in group A (control group; Group B was irradiated with Er:YAG laser for 10 seconds under air and water spray; and Group C was irradiated with Nd:YAG laser for 10 seconds under air and water spray. After treatment, the samples were analyzed by FT-Raman spectroscopy. Results. The carbonate content evaluation with regard to the integrated area under the curve (1065/960 cm–1 exhibited a significant reduction in its ratio in groups B and C. The organic content (2935/960 cm-1 area exhibited a significant decrease after laser irradiation in group B and C. Conclusion. The results showed that the mineral and organic matrices of enamel structure were affected by laser irradiation; therefore, it might be a suitable method for caries prevention.

  8. 3D YAG laser cutting robot. 3 jigen YAG laser setsudan robot

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, Y. (Matsushita Electric Industrial Co. Ltd., Osaka (Japan))

    1991-11-01

    The present status was introduced of three-dimensional processing by the YAG laser multi-articulation robot to introduce the focusing system. The lowering in locus accuracy of multi-articulation robot is caused by the accuracy and time of computation to interpolate the locus, response characteristics of servo system, and calibration problem of mechanical/structural system. Also as low in output power of laser, it has problem in focusing the energy in the radiating optical system. A focusing system, high in response velocity, is necessary in the processor to use the optical fiber in the optical transfer system. As processing and measuring at an identical spot, the present system can integrate the detection use electrode and nozzle so as to use an electrostatic capacity type sensor, high in response frequency. To avoid the interference with jig, etc., the nozzle of radiating unit was integrated with the detection use electrode so that development was made of height sensor, capable of executing the three-dimensional processing. The present robot is characterized by a standardized equipment of control system with a sliding shaft, independent of the operational shaft properly of robot in order to be exclusively used for the focusing. 9 figs.

  9. Evaluation in vitro of effects of Er:YAG and Nd:YAG lasers irradiation on root canal wall, by stereoscopy, scanning electron micrography and thermographic camera; Avaliacao in vitro dos efeitos da irradiacao laser de Er:YAG e Nd:YAG na parede dentinaria do canal radicular, sob observacao do estereoscopio, da micrografia eletronica e da camera termografica

    Energy Technology Data Exchange (ETDEWEB)

    Goya, Claudia

    2001-07-01

    This study was carried out to evaluate in vitro the effects of Nd:YAG laser and Er:YAG laser irradiation in the root canal wall by SEM, evaluating the apical leakage and the temperature changes during the laser irradiation. Seventy four extracted human teeth were used, they were instrumented and divided into seven groups of 10 teeth each. The teeth were evaluated through stereoscopy, by SEM, and with the thermographic camera. The Nd:YAG laser irradiation parameters were 100 mJ/p, 15 Hz, and Er:YAG laser were 160 mJ/p and 10 Hz, the irradiation was 4 times at 2 mm/sec speed, with 20 sec interval. The apical leakage was not observed in the teeth irradiated by Nd:YAG laser alone or in association with Er:YAG laser. However in the teeth irradiated only by the Er:YAG laser we observed a little leakage. By SEM observation the Nd:YAG laser irradiation showed melting and recrystallization in the dentin surface closing dentinal tubules, and in the samples irradiated by Er:Y AG laser a clean surface, opened dentinal tubules, and the combination by two lasers, showed melting covering some dentinal tubules The thermographic study found the temperature increase was not more than 6 deg C. This study showed the safety parameters applications of Er:YAG laser in association with Nd:YAG laser in root canal treatment, in order to not cause thermal damages to the periodontal tissues. (author)

  10. Corrosion Resistant Cladding by YAG Laser Welding in Underwater Environment

    International Nuclear Information System (INIS)

    Tsutomi Kochi; Toshio Kojima; Suemi Hirata; Ichiro Morita; Katsura Ohwaki

    2002-01-01

    It is known that stress-corrosion cracking (SCC) will occur in nickel-base alloys used in Reactor Pressure Vessel (RPV) and Internals of nuclear power plants. A SCC sensitivity has been evaluated by IHI in each part of RPV and Internals. There are several water level instrumentation nozzles installed in domestic BWR RPV. In water level instrumentation nozzles, 182 type nickel-base alloys were used for the welding joint to RPV. It is estimated the SCC potential is high in this joint because of a higher residual stress than the yield strength (about 400 MPa). This report will describe a preventive maintenance method to these nozzles Heat Affected Zone (HAZ) and welds by a corrosion resistant cladding (CRC) by YAG Laser in underwater environment (without draining a reactor water). There are many kinds of countermeasures for SCC, for example, Induction Heating Stress Improvement (IHSI), Mechanical Stress Improvement Process (MSIP) and so on. A YAG laser CRC is one of them. In this technology a laser beam is used for heat source and irradiated through an optical fiber to a base metal and SCC resistant material is used for welding wires. After cladding the HAZ and welds are coated by the corrosion resistant materials so their surfaces are improved. A CRC by gas tungsten arc welding (GTAW) in an air environment had been developed and already applied to a couple of operating plants (16 Nozzles). This method was of course good but it spent much time to perform because of an installation of some water-proof working boxes to make a TIG-weldability environment. CRC by YAG laser welding in underwater environment has superior features comparing to this conventional TIG method as follows. At the viewpoint of underwater environment, (1) an outage term reduction (no drainage water). (2) a radioactive exposure dose reduction for personnel. At that of YAG laser welding, (1) A narrower HAZ. (2) A smaller distortion. (3) A few cladding layers. A YAG laser CRC test in underwater

  11. Correlating states across isomers in 152Ho isotope

    International Nuclear Information System (INIS)

    Pramanik, Dibyadyuti; Dey, G.; Sarkar, S.; Bisoi, A.; Ray, S.; Kshetri, R.; Ray, I.; Pradhan, M.K.; Goswami, A.; Banerjee, P.; Mukherjee, A.; Bhattacharya, S.; Saha Sarkar, M.; Chakraborty, A.; Krishichayan; Ganguly, S.; Ray Basu, M.; Ganguly, G.; Raut, R.; Ghugre, S.S.; Sinha, A.K.; Basu, S.K.

    2011-01-01

    The odd-odd 152 Ho (N = 85) is a very interesting candidate for investigation of interplay of single - particle oblate states and prolate collective states, because it is situated between the N=82 shell closure and the strongly collective N > 87 region. It has been shown that there is a possibility of shape coexistence even at lower spins in 153 Ho. The structural evolution of Ho isotopes from A = 151 to 154 has also been studied. The features observed have been interpreted theoretically using shell model as well as Total Routhian surface calculations. Results have been combined with that for 153 Ho to study the evolution of structural features in these Ho isotopes with increasing neutron numbers and increasing spin. In the present work, experimental data on 152 Ho have been analysed to connect the three groups of transitions and confirm the possibility of a fourth isomer in the excitation spectrum

  12. High spin levels in 151Ho

    International Nuclear Information System (INIS)

    Gizon, J.; Gizon, A.; Andre, S.; Genevey, J.; Jastrzebski, J.; Kossakowski, R.; Moszinski, M.; Preibisz, Z.

    1981-02-01

    We report here on the first study of the level structure of 151 Ho. High spin levels in 151 Ho have been populated in the 141 Pr + 16 O and 144 Sm + 12 C reactions. The level structure has been established up to 6.6 MeV energy and the spins and particles determined up to 49/2 - . Most of the proposed level configurations can be explained by the coupling of hsub(11/2) protons to fsub(7/2) and/or hsub(9/2) neutrons. An isomer with 14 +- 3 ns half-life and a delayed gamma multiplicity equal to 17 +- 2 has been found. Its spin is larger than 57/2 h units

  13. Laser reduction of specific microorganisms in the periodontal pocket using Er:YAG and Nd:YAG lasers: a randomized controlled clinical study.

    Science.gov (United States)

    Grzech-Leśniak, K; Sculean, A; Gašpirc, Boris

    2018-05-15

    The objective of this study was to evaluate the microbiological and clinical outcomes following nonsurgical treatment by either scaling and root planing, combination of Nd:YAG and Er:YAG lasers, or by Er:YAG laser treatment alone. The study involved 60 patients with generalized chronic periodontitis, randomly assigned into one of three treatment groups of 20 patients. The first group received scaling and root planing by hand instruments (SRP group), the second group received Er:YAG laser treatment alone (Er group), and the third group received combined treatment with Nd:YAG and Er:YAG lasers (NdErNd group). Microbiological samples, taken from the periodontal pockets at baseline and 6 months after treatments, were assessed with PET Plus tests. The combined NdErNd laser (93.0%), followed closely by Er:YAG laser (84.9%), treatment resulted in the highest reduction of all bacteria count after 6 months, whereas SRP (46.2%) failed to reduce Treponema denticola, Peptostreptococcus micros, and Capnocytophaga gingivalis. Full-mouth plaque and bleeding on probing scores dropped after 6 months and were the lowest in both laser groups. The combination of NdErNd resulted in higher probing pocket depth reduction and gain of clinical attachment level (1.99 ± 0.23 mm) compared to SRP (0.86 ± 0.13 mm) or Er:YAG laser alone (0.93 ± 0.20 mm) in 4-6 mm-deep pockets. Within their limits, the present results provide support for the combination of Nd:YAG and Er:YAG lasers to additionally improve the microbiological and clinical outcomes of nonsurgical periodontal therapy in patients with moderate to severe chronic periodontitis.

  14. Gamma-ray relative energy response of Ce: YAG crystal

    International Nuclear Information System (INIS)

    Zhang Jianhua; Zhang Chuanfei; Hu Mengchun; Peng Taiping; Wang Zhentong; Tang Dengpan; Zhao Guangjun

    2010-01-01

    Gamma-ray relative energy response of Ce: YAG crystal, which is important for pulsed γ-ray measurement, was studied in this work.The Ce: YAG crystal, which was developed at Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, was aligned point by point with γ-rays scattered from an industrial 60 Co line source. The γ-ray relative energy response was calculated using the mass attenuation coefficient. The results show that the numerical calculation method of γ-ray relative energy response is reliable, and the experimental method with multi-energy point γ-ray by Compton scattering is also feasible, that can be used for checking up correctness of the numerical calculation results. (authors)

  15. Cutting of nonmetallic materials using Nd:YAG laser beam

    Institute of Scientific and Technical Information of China (English)

    Bashir Ahmed Tahir; Rashid Ahmed; M. G. B. Ashiq; Afaq Ahmed; M. A. Saeed

    2012-01-01

    This study deals with Nd:YAG laser cutting nonmetallic materials,which is one of the most important and popular industrial applications of laser.The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed.For approximate cutting depth,a theoretical study is conducted in terms of material property and cutting speed.Results show a nonlinear relation between the cutting depth and input energy.There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s.An extra energy is utilized in the deep cutting.It is inferred that as the laser power increases,cutting depth increases.The experimental outcomes are in good agreement with theoretical results.This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting,scribing,trimming,engraving,and marking nonmetallic materials.

  16. Photo-switch of pulsed Nd:YAG laser

    International Nuclear Information System (INIS)

    Ketta, W.W.J.

    1989-01-01

    In this work passive Q-switching and its effect on the output laser beam from a pulsed Nd:YAG laser was studied. This was achieved using the photochemically stable (BDNI) dye after dissolving it in dichloroethane. The absorption spectra of the dye solution and how suitable to use with Nd:YAG laser was also dealt with. Cooling unit for the laser system, a detector to detect the output pulse, and an electronic counter to measure the pulse duration were constructed. In the free-running regime, the divergence angle was measured. The form of the output, its energy, and how it is affected by the pumping energy were also studied. In the Q-switching regime, the relation between output and pumping energies was studied and compared to the same relation under the free-running regime. 5 tabs.; 33 figs.; 57 refs

  17. Pulsed Tm:YAG laser ablation of knee joint tissues

    Science.gov (United States)

    Shi, Wei-Qiang; Vari, Sandor G.; Duffy, J. T.; Miller, J. M.; Weiss, Andrew B.; Fishbein, Michael C.; Grundfest, Warren S.

    1992-06-01

    We investigated the effect of a free-running 2.01 micron pulsed Tm:YAG laser on bovine knee joint tissues. Ablation rates of fresh fibrocartilage, hyaline cartilage, and bone were measured in saline as a function of laser fluence (160 - 640 J/cm2) and fiber core size (400 and 600 microns). All tissues could be effectively ablated and the ablation rate increased linearly with the increasing fluence. Use of fibers of different core sizes, while maintaining constant energy fluence, did not result in significant difference in ablation rate. Histology analyses of the ablated tissue samples reveal average Tm:YAG radiation induced thermal damage (denatunalization) zones ranging between 130 and 540 microns, depending on the laser parameters and the tissue type.

  18. Tunable eye-safe Er:YAG laser

    International Nuclear Information System (INIS)

    Němec, M; Šulc, J; Indra, L; Fibrich, M; Jelínková, H

    2015-01-01

    Er:YAG crystal was investigated as the gain medium in a diode (1452 nm) pumped tunable laser. The tunability was reached in an eye-safe region by an intracavity birefringent filter. The four tuning bands were obtained peaking at wavelengths 1616, 1632, 1645, and 1656 nm. The broadest continuous tunability was 6 nm wide peaking at 1616 nm. The laser was operating in a pulsed regime (10 ms pulse length, 10 Hz repetition rate). The maximum mean output power was 26.5 mW at 1645 nm. The constructed system demonstrated the tunability of a resonantly diode-pumped Er:YAG laser which could be useful in the development of compact diode-pumped lasers for spectroscopic applications. (paper)

  19. Cutting of nonmetallic materials using Nd:YAG laser beam

    International Nuclear Information System (INIS)

    Tahir, Bashir Ahmed; Ashiq, M.G. B.; Saeed, M.A.; Ahmed, Rashid; Ahmed, Afaq

    2012-01-01

    This study deals with Nd:YAG laser cutting nonmetallic materials, which is one of the most important and popular industrial applications of laser. The main theme is to evaluate the effects of Nd:YAG laser beam power besides work piece scanning speed. For approximate cutting depth, a theoretical study is conducted in terms of material property and cutting speed. Results show a nonlinear relation between the cutting depth and input energy. There is no significant effect of speed on cutting depth with the speed being larger than 30 mm/s. An extra energy is utilized in the deep cutting. It is inferred that as the laser power increases, cutting depth increases. The experimental outcomes are in good agreement with theoretical results. This analysis will provide a guideline for laser-based industry to select a suitable laser for cutting, scribing, trimming, engraving, and marking nonmetallic materials. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  20. Effects of Er:YAG laser irradiation on human cartilage

    Science.gov (United States)

    Glinkowski, Wojciech; Brzozowska, Malgorzata; Ciszek, Bogdan; Rowinski, Jan; Strek, Wieslaw

    1996-03-01

    Irradiation of the hyaline or fibrous cartilage excised from the body of a human cadaver with Er:YAG laser beam, single pulse with a dose of 1 J, produces a crater with a depth of approximately 500 micrometers and a diameter varying from 5 to 300 micrometers. Histological examination has revealed that the laser-made craters were surrounded by a thin rim (2-10 micrometer) of charred and coagulated tissue. No damage was observed in the cartilage surrounding the rim. The presence of sharp demarcation between the tissue areas ablated by laser energy and the undamaged areas argues for the potential usefulness of the Er:YAG laser in surgery of cartilages.

  1. Nd:YAG laser in caries prevention: a clinical study

    International Nuclear Information System (INIS)

    Boari, Heloisa Gomes Dimiranda

    2000-01-01

    The caries prevention by using laser irradiation has been investigated during the last 30 years. The Nd: YAG laser associated with acidulated phosphate fluoride has been shown as a very promising technique for enamel caries prevention. The aim of this work was to clinically evaluate the efficiency of Nd: YAG laser associated with acidulated phosphate fluoride in pit and fissure caries prevention of children and adolescents. In this work it was determined the dye that enhance the effect of Nd: YAG laser in enamel. It was selected 242 pre-molar and molar teeth from 33 children and adolescents, aged from 7 to 15 years old. The selected teeth were free from caries or decalcification marks (active white marks) to the clinical and radiographic exams. The teeth were divided into two groups: the first group was laser irradiated and their homologous remained as a control. The right side teeth were dye-assisted Nd:YAG laser irradiated. The dye solution was a moisture of dust coal and equal parts of water and alcohol. The irradiation conditions were 60 mJ/10 Hz, optical fiber in contact mode, with diameter of 300 μm, resulting in an energy density of 84,9 J/cm 2 . The oclusal surface of the teeth was completely irradiated, specially on the slopes and in the deepest part of the pits and fissures. This procedure was repeated three times. In the sequence it was applied the acidulated phosphate fluoride for 4 minutes. On the left side teeth - control group- only acidulated phosphate fluoride was applied for the same time. The final examination considered the presence of caries and active white marks after a period of one year. There were statistical significant differences (p < 0.01) between the lased + fluoride group and the non irradiated group. The present study concluded that the technique used in this work can be an alternative clinical method for caries prevention. (author)

  2. Luminescence properties and energy transfer processes in YAG:Yb,Er single crystalline films

    International Nuclear Information System (INIS)

    Zorenko, Yu.; Gorbenko, V.; Savchyn, V.; Batentschuk, M.; Osvet, A.; Brabec, C.

    2013-01-01

    The paper is dedicated to the study of the optical properties of YAG:Yb,Er single-crystalline films (SCF) grown by liquid phase epitaxy. The absorption, cathodoluminescence and time-resolved photoluminescence spectra and photoluminescence decay curves were measured for the SCFs with different doping levels of Er 3+ (from 0.6 to 4.2 at.%) and Yb 3+ (from 0.1 to 0.6 at.%). The spectra, excited by synchrotron radiation in the fundamental absorption range of the YAG and in the intraionic absorption bands of both dopants, reveal energy transfer from the YAG host to the Er 3+ and Yb 3+ ions and between these ions. -- Highlights: •Growth of YAG:Yb,Er single crystalline films by LPE method. •Peculiarities of luminescence of YAG:Yb,Er films with different Er–Yb content. •Yb–Er energy transfer processes in YAG hosts

  3. Heat effect of pulsed Er:YAG laser radiation

    Science.gov (United States)

    Hibst, Raimund; Keller, Ulrich

    1990-06-01

    Pulsed Er:YAG laser radiation has been found to be effective for dental enamel and dentin removal. Damage to the surrounding hard tissue is little, but before testing the Er:YAG laser clinically for the preparation of cavities, possible effects on the soft tissue of the pulp must be known. In order to estimate pulp damage , temperature rise in dentin caused by the laser radiation was measured by a thermocouple. Additionally, temperature distributions were observed by means of a thermal imaging system. The heat effect of a single Er:YAG laser pulse is little and limited to the vicinity of the impact side. Because heat energy is added with each additional pulse , the temperature distribution depends not only on the radiant energy, but also on the number of pulses and the repetition rate. Both irradiation conditions can be found , making irreversible pulp damage either likely or unlikely. The experimental observations can be explained qualitatively by a simple model of the ablation process.

  4. Bactericidal effect of Nd:YAG laser irradiation in endodontics

    Science.gov (United States)

    Aun, Carlos E.; Barberini, Alexandre F.; Camargo, Selma C. C.; Silva Kfouri, Luciana; Lorenzetti Simionato, Maria R.

    1999-05-01

    The success of endodontic therapy is based on the elimination of bacterial colonization from the endodontic system and periapical tissues. Recent studies have been showing the bactericidal effect of laser in root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canal treatment. The propose of the study is to evaluate the effect of Nd:YAG laser irradiation in contaminated root canals from upper central incisor. For the experiment 12 teeth were selected, respect at the apical third, sterilized, and 10 μm Streptococcus sanguis liquid culture were inoculated in the root canals. The laser test groups were irradiated with Nd:YAG laser at standard setting of 15Hz, 100mj and 1,5 W for 10, 20 and 30 seconds each in slow helicoidal movements from the apex to the top using a 300 micrometers fiber. After the procedure the specimens were placed in Tryptic Soy Agar, the number of colony forming units was evaluated. The experiment showed a significant reduction on viability of Streptococcus sanguis at the respective time of 20 and 30 seconds.

  5. The quantitative analysis of 163Ho source by PIXE

    International Nuclear Information System (INIS)

    Sera, K.; Ishii, K.; Fujioka, M.; Izawa, G.; Omori, T.

    1984-01-01

    We have been studying the electron-capture in 163 Ho as a method for determining the mass of electron neutrino. The 163 Ho sources were produced with the 164 Dy(p,2n) reaction by means of a method of internal irradiation 2 ). We applied the PIXE method to determine the total number of 163 Ho atoms in the source. Proton beams of 3 MeV and a method of ''external standard'' were employed for nondestructive analysis of the 163 Ho source as well as an additional method of ''internal standard''. (author)

  6. Cathode ray tube screens

    International Nuclear Information System (INIS)

    Cockayne, B.; Robbins, D.J.; Glasper, J.L.

    1982-01-01

    An improved cathode ray tube screen is described which consists of a single- or a poly-crystalline slice of a material such as yttrium aluminium garnet in which dopants such as Tb 3 + , Eu 3 + , Ce 3 + or Tm 3 + are ion implanted to different depths or in different areas of the screen. Annealing the screen removes lattice damage caused by the ion implanting and assists the diffusion of the dopant into the crystal. (U.K.)

  7. Characterisation of debris from laser and mechanical cutting of bone.

    Science.gov (United States)

    Rachmanis, Nikolaos; McGuinness, Garrett B; McGeough, Joseph A

    2014-07-01

    Laser cutting of bones has been proposed as a technology in orthopaedic surgery. In this short study, the laser-bone interaction was examined using a pulsed erbium-doped yttrium aluminium garnet laser and compared to a conventional cutting technique. Microscopic analysis revealed the nature of waste debris and showed higher proportions of finer particles for conventional sagittal sawing compared to laser cutting. © IMechE 2014.

  8. Effects of neodymium concentration on optical characteristics of polycrystalline Nd:YAG laser materials

    International Nuclear Information System (INIS)

    Ikesue, A.; Kamata, K.; Yoshida, K.

    1996-01-01

    A neodymium-doped yttrium-aluminum garnet (Y 3 Al 5 O 12 , YAG) (Nd:YAG) ceramic that contained 0.3--4.8 at.% neodymium additives and exhibited nearly the same optical properties as those of a single crystal was fabricated by a solid-state reaction method using high-purity powders. Although the integrated absorption intensity of the 2 H 9/2 + 4 F 5/2 bands simply increased as the neodymium concentration in the YAG ceramics decreased, the fluorescence intensity of the 2.4 at.% Nd:YAG ceramic was the strongest among Nd:YAG ceramics with various neodymium concentrations and a 0.9 at.% Nd:YAG single crystal. An oscillation experiment was performed on a continuous-wave (cw) laser with a diode-laser exciting system using those ceramics and the single crystal. The oscillation threshold and slope efficiency in that analysis were 309 mW and 28%, respectively, for the 1.1 at.% Nd:YAG ceramics and 356 mW and 40%, respectively, for the 2.4 at.% Nd:YAG ceramics. The lasing characteristics of the ceramics in the present work were superior to those of a 0.9 at.% Nd:YAG single crystal that was fabricated by the Czochralski (Cz) method

  9. Fabrication of Nd:YAG transparent ceramics with both TEOS and MgO additives

    International Nuclear Information System (INIS)

    Yang Hao; Qin Xianpeng; Zhang Jian; Wang Shiwei; Ma Jan; Wang Lixi; Zhang Qitu

    2011-01-01

    Research highlights: → It is well known that the use of TEOS as sintering aid is required to reach fully dense and transparent Nd:YAG ceramics. However, it is difficult to produce high quality transparent Nd:YAG ceramics only using TEOS as sintering aid. In this present work, high quality transparent Nd:YAG ceramic was fabricated using both TEOS and MgO as sintering aids. There have been few reports that both TEOS and MgO were co-added as sintering aids in YAG or Nd:YAG transparent ceramics to date. The transmittance of Nd:YAG ceramic is 83.8% at 1064 nm. The effect of MgO on the optical properties of transparent ceramics was also studied. - Abstract: Neodymium doped YAG transparent ceramics were fabricated by vacuum reactive sintering method using commercial α-Al 2 O 3 , Y 2 O 3 and Nd 2 O 3 powders as the starting materials with both tetraethyl orthosilicate (TEOS) and MgO as sintering aids. The morphologies and microstructure of the powders and Nd:YAG transparent ceramics were investigated. Fully dense Nd:YAG ceramics with average grain size of ∼10 μm were obtained by vacuum sintering at 1780 deg. C for 8 h. No pores and grain-boundary phases were observed. The in-line transmittance of the ceramic was 83.8% at 1064 nm.

  10. Gingival melanin depigmentation by Er:YAG laser: A literature review.

    Science.gov (United States)

    Pavlic, Verica; Brkic, Zlata; Marin, Sasa; Cicmil, Smiljka; Gojkov-Vukelic, Mirjana; Aoki, Akira

    2018-04-01

    Laser ablation is recently suggested as a most effective and reliable technique for depigmentation of melanin hyperpigmented gingiva. To date, different lasers have been used for gingival depigmentation (CO 2 , diode, Nd:YAG, Er:YAG and Er,Cr:YSGG lasers). The use of Er:YAG laser for depigmentation of melanin hyperpigmented gingiva has gained increasing importance in recent years. The purpose of this study was to report removal of gingival melanin pigmentation using an Er:YAG laser in a literature review. The main outcomes, such as improvement of signs (clinical parameters of bleeding, erythema, swelling and wound healing), symptoms (pain) and melanin recurrence/repigmentation were measured. The literature demonstrated that depigmentation of gingival melanin pigmentation can be performed safely and effectively by Er:YAG laser resulting in healing and an esthetically significant improvement of gingival discoloration. Thus, Er:YAG laser seems to be safe and useful in melanin depigmentation procedure. However, the main issue in giving the final conclusion of the optimal Er:YAG laser use in melanin depigmentation is that, to date, studies are offering completely discrepant Er:YAG laser procedure protocols (complex settings of laser parameters), and different criteria for the assessment of depigmentation and repigmentation (recurrence), thus hampering the comparison of the results. Therefore, further studies are necessary to give an optimal recommendation on the use of Er:YAG laser in gingival melanin hyperpigmentation.

  11. Q-switched Nd:YAG/V:YAG microchip 1338 nm laser for laser-induced breakdown spectroscopy

    Science.gov (United States)

    Šulc, Jan; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2017-12-01

    Q-switched microchip laser emitting radiation at wavelength 1338nm was tested as a radiation source for laser induced breakdown spectroscopy (LIBS). This laser used sandwich crystal which combined in one piece the cooling part (undoped YAG crystal 4mm long), the active laser part (Nd:YAG crystal 12mm long), and the saturable absorber (V:YAG crystal 0.7mm long). The diameter of this crystal was 5 mm. The microchip resonator consisted of dielectric mirrors directly deposited on the monolith crystal surfaces. The pump mirror (HT @ 808 nm, HR @ 1.3 ¹m) was placed on the undoped YAG part. The output coupler (R = 90% @ 1338 nm) was placed on the V:YAG part. The fibre-coupled 808nm pumping laser diode was operating in pulsed regime (rep. rate 250 Hz, pulse width 300 ¹s, pulse energy 6 mJ). Using this pumping, stable and high reproducible Q-switched pulses were generated at wavelength 1338 nm. Pulse length was 6.2 ns (FWHM) and the mean output power was 33mW. The single pulse energy and peak power was 0.13mJ and 21kW, respectively. Laser was operating in fundamental TEM00 mode. The laser radiation was focused on a tested sample using single plano-convex lens (focal length 75 mm). The focal spot radius was 40 ¹m. The corresponding peak-power density was 0.83GW/cm2. The laser induced break-down was successfully reached and corresponding laser-induced plasma spectra were recorded for set of metallic elements (Cu, Ag, Au, In, Zn, Al, Fe, Ni, Cr) and alloys (Sn-Pb solder, duralumin, stainless-steel, brass). To record the spectra, StellarNet BLACK-Comet concave grating CCD-based spectrometer was used without any special collimation optics. Thanks to used laser wavelength far from the detector sensitivity, no special filtering was needed to overcome the CCD dazzling. The constructed laser could significantly improve repletion-rate of up-to-date LIBS devices.

  12. PENGENDALIAN DALAM PENERBITAN IZIN GANGGUAN (HO

    Directory of Open Access Journals (Sweden)

    Pebriana Marlinda

    2017-04-01

    Full Text Available Abstrak :            Penelitian tentang pengendalian dalam penerbitan izin gangguan (HO di Kecamatan Margahayu Kabupaten Bandung menjelaskan tentang tahap-tahap pengendalian yang dilakukan oleh aparat Kecamatan Margahayu. Pengendalian dilakukan untuk memastikan agar penerbitan izin gangguan (HO berjalan dengan efektif. Namun, masih ada pelaku usaha yang belum memiliki surat izin gangguan (HO ataupun pelaku usaha yang sudah memiliki surat izin gangguan (HO akan tetapi kegiatan usahanya merugkan orang lain seperti sampah yang berserakan, polusi udara, polusi suara, dan lain-lain.                            Metode penelitian yang digunakan adalah metode penelitian deduktif kualitatif dengan teknik pengumpulan data melalui studi kepustakaan dan studi lapangan yang meliputi observasi dan wawancara mendalam. Adapun penentuan informan dalam penelitian ini dipilih berdasarkan pertimbangan-pertimbangan dengan pihak-pihak yang terkait dalam pengendalian. Kemudian data yang diperoleh dari hasil wawancara dipaparkan dengan langkah-langkah yang meliputi: reduksi data, penyajian data, menarik kesimpulan/verifikasi. Teori yang digunakan penulis dalam penelitian ini adalah teori dari Stephen P. Robbins tentang tahap-tahap pengendalian yaitu: mengukur kinerja aktual, membandingkan kinerja aktual dengan standar, dan mengambil tindakan manajerial.                            Kesimpulan dari hasil penelitian ini adalah pengendalian yang dilakukan olehaparat Kecamatan Margahayu telah melalui tahap-tahap pengendalian yaitu: mengukur kinerja aktual, membandingkan kinerja aktual dengan standar, dan mengambil tindakan manajerial. Namun perlu dilakukan penguatan di setiap tahap pengendalian terutama pada tahap mengukur kinerja aktual dan pada tahap mengambil tindakan manajerial                            Penelitian tentang pengendalian dalam penerbitan izin gangguan (HO di Kecamatan

  13. EGR-1 regulates Ho-1 expression induced by cigarette smoke

    International Nuclear Information System (INIS)

    Chen, Huaqun; Wang, Lijuan; Gong, Tao; Yu, Yang; Zhu, Chunhua; Li, Fen; Wang, Li; Li, Chaojun

    2010-01-01

    As an anti-oxidant molecule, heme oxygenase-1 (HO-1) has been implicated in the protection of lung injury by cigarette smoke (CS). The mechanisms regulating its expression have not been defined. In this report, the role of early growth response 1 (EGR-1) in the regulation of Ho-1 expression was investigated. In C57BL/6 mice with CS exposure, HO-1 was greatly increased in bronchial epithelial cells and alveolar inflammatory cells. In primary cultured mouse lung fibroblasts and RAW264.7 cells exposed to cigarette smoke water extract (CSE), an increase in HO-1 protein level was detected. In addition, CSE induced HO-1 expression was decreased in Egr-1 deficient mouse embryo fibroblasts (Egr-1 -/- MEFs). Nuclear localization of EGR-1 was examined in mouse lung fibroblasts after exposure to CSE. Luciferase reporter activity assays showed that the enhancer region of the Ho-1 gene containing a proposed EGR-1 binding site was responsible for the induction of HO-1. A higher increase of alveolar mean linear intercept (Lm) was observed in lung tissues, and a larger increase in the number of total cells and monocytes/macrophages from bronchial alveolar lavage fluid was found in CS-exposed mice by loss of function of EGR-1 treatment. In summary, the present data demonstrate that EGR-1 plays a critical role in HO-1 production induced by CS.

  14. Lattice effects in HoVo(3) single crystal

    NARCIS (Netherlands)

    Sikora, M.; Marquina, C.; Ibarra, M. R.; Nugroho, A. A.; Palstra, T. T. M.

    We report the study of lattice effects in the Mott insulator HoVO3 performed by means of linear thermal expansion on a single crystal in the temperature range 10-290 K. The holmium orthovanadate HoVO3 reveals gradual orbital ordering (OO) below T-OO = 200K and orders antiferromagnetically at T-N =

  15. Fer-Ho Anaphora in Catalan: Semantic and Discourse Properties

    Science.gov (United States)

    Busquets, Joan

    2018-01-01

    This paper considers the anaphoric status of the pro-form "fer-ho" (do it) in Catalan [This paper contains some ideas included in Busquets (2005)]. I discuss some anaphoric properties of "fer-ho" as deep anaphora. I also compare these properties to those of other types of anaphora, like VPE and pseudogapping (pg). I show that…

  16. Management strategies in malignant glaucoma secondary to antiglaucoma surgery

    Directory of Open Access Journals (Sweden)

    Zuo-Hong Wu

    2016-01-01

    Full Text Available AIM: To assess the outcomes of various interventions for malignant glaucoma (MG. METHODS: A retrospective, comparative analysis of case series were performed on 38 eyes of 35 MG patients treated in Aier Eye Hospital of Wuhan between Jan. 2009 and Dec. 2012. Numerous treatments were administered including medical therapy, neodymium: yttrium- aluminium-garnet (Nd:YAG laser posterior capsulotomy and hyaloidotomy as well as 3 surgical options. The characteristic, treatment option and outcome of MG in every individual patient were reviewed and analyzed among all patients who were followed up for an average of 27.1±9.1mo. RESULTS: Four eyes of 3 patients achieved complete resolution with medical therapy. Nd:YAG laser posterior capsulotomy and hyaloidotomy were performed on 2 eyes, both of which achieved resolution after initial intervention. Thirty-two eyes were given surgical treatments with anterior vitrectomy- reformation of anterior chamber in 13 eyes, phacoemulsification- intraocular lens implantation in 10 eyes and phacoemulsification- intraocular lens implantation- anterior vitrectomy in 9 eyes. Resolution of MG was seen in almost all patients. The mean intraocular pressure decreased from 41.87±9.44 mm Hg at presentation to 15.84±3.73 mm Hg at the last visit. The mean anterior chamber depth improved from 0.28±0.27 mm to 2.28±0.19 mm. Twenty eyes with preoperative visual acuity better than counting figure/ 50 cm had various visual improvements. Complications occurred in 3 eyes of 3 patients including bleeding at the entry site of vitrectomy into vitreous cavity, corneal endothelial decompensation and allergic to atropine respectively. CONCLUSION: MG occurs as a result of multiple mechanisms involved simultaneously or sequentially.Medical therapy is advocated as the initial treatment, laser therapy is beneficial in pseudophakic eyes, and different surgical regimen is recommended based on different pathogenesis of MG when non-response occurs

  17. Management of a Recurrent Pyogenic Granuloma of the Hard Palate with Diode Laser: A Case Report.

    Science.gov (United States)

    Hasanoglu Erbasar, Güzin Neda; Senguven, Burcu; Gultekin, Sibel Elif; Cetiner, Sedat

    2016-01-01

    Pyogenic granuloma (PG) is a prevalent inflammatory hyperplasia of skin and oral mucosa which is often caused by constant low-grade local irritation, traumatic injury or hormonal factors. In many cases, gingival irritation and inflammation due to poor oral hygiene are precipitating factors. Oral PG occurs predominantly on the gingiva, but it is also encountered on the lips, tongue, buccal mucosa and rarely on the hard palate. Although surgical excision is the first choice of treatment, many other treatment modalities could be counted such as cryosurgery, sodium tetradecyl sulfate sclerotherapy, intralesional steroids, flash lamp pulsed dye laser, neodymium-doped yttrium aluminium garnet (Nd:YAG) laser, carbon dioxide (CO2) laser, erbium-doped yttrium aluminum garnet (Er:YAG) lasers and diode laser have been suggested. After surgical excision recurrence occurs up to 16% of these lesions. It is believed that recurrence ensues as a result of incomplete excision, failure to eliminate etiologic factors or repeated trauma. A 50-year-old female was referred to the Department of Oral Surgery, Gazi University, School of Dentistry, complaining of a swelling and growth on the right side of the hard palate for four months. Patient reported a similar growth in the same area about two years earlier, which had turned out to be a PG by histopathology. The treatment plan included surgical excision of the lesion using diode laser. The patient reported no pain after the surgery. She was discharged with a prescription of chlorhexidine mouthwash and necessary post-operative instructions. At 7 days follow up visit, immediate recurrence of the lesion was observed, and it was excised by diode laser with 2 mm margins at its clinical periphery, to a depth up to the periosteum, by the same operator. No recurrence or scarring was observed in 14 months follow-up. Although diode laser is a secure and efficient technique for the treatment of intraoral PG, in order to minimize its recurrence, the

  18. MoTe2 saturable absorber for passively Q-switched Ho,Pr:LiLuF4 laser at ∼3 μm

    Science.gov (United States)

    Yan, Zhengyu; Li, Tao; Zhao, Shengzhi; Yang, Kejian; Li, Dechun; Li, Guiqiu; Zhang, Shuaiyi; Gao, Zijing

    2018-03-01

    Multilayer molybdenum ditelluride (MoTe2) nanosheets were prepared by liquid-phase exfoliation (LPE) method. A YAG-based MoTe2 saturable absorption (SA) was consequently fabricated. The MoTe2-SA was employed in a passively Q-switched Ho,Pr:LiLuF4 laser at 2.95 μm. Under the absorbed pump power of 3.8 W, an average output power of 90 mW was achieved. The shortest pulse duration of 670 ns was generated with an output power of 73 mW and a repetition rate of 76.46 kHz, corresponding to a pulse energy of 0.95 μJ.

  19. Preparation of .sup.166./sup.Ho-Macroaggregates and .sup.166./sup.Ho-Chitosan for the Radiotherapy

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Mirzajevová, Marcela

    2002-01-01

    Roč. 29, č. 2 (2002), s. 382 ISSN 1619-7070 R&D Projects: GA MZd NM6828; GA AV ČR KSK4055109 Keywords : Holmium-166 * 166 Ho-macroaggregates * 166 Ho-chitosan Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  20. Transmission of Er:YAG laser through different dental ceramics.

    Science.gov (United States)

    Sari, Tugrul; Tuncel, Ilkin; Usumez, Aslihan; Gutknecht, Norbert

    2014-01-01

    The aim of this study was to determine the erbium-doped yttrium aluminum garnet (Er:YAG) laser transmission ratio through different dental ceramics with different thicknesses. Laser debonding procedure of adhesively luted all-ceramic restorations is based on the transmission of laser energy through the ceramic and the ablation of resin cement, because of the transmitted laser energy. Five different dental ceramics were evaluated in this study: sintered zirconium-oxide core ceramic, monolithic zirconium-oxide ceramic, feldspathic ceramic, leucite-reinforced glass ceramic, and lithium disilicate-reinforced glass ceramic. Two ceramic discs with different thicknesses (0.5 and 1 mm) were fabricated for each group. Ceramic discs were placed between the sensor membrane of the laser power meter and the tip of the contact handpiece of an Er:YAG laser device with the aid of a custom- made acrylic holder. The transmission ratio of Er:YAG laser energy (500 mJ, 2 Hz, 1 W, 1000 μs) through different ceramic discs was measured with the power meter. Ten measurements were made for each group and the results were analyzed with two way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests. The highest transmission ratio was determined for lithium disilicate-reinforced ceramic with 0.5 mm thickness (88%) and the lowest was determined for feldspathic ceramic with 1 mm thickness (44%). The differences among the different ceramics and between the different thicknesses were significant (pCeramic type and thickness should be taken into consideration to adjust the laser irradiation parameters during laser debonding of adhesively luted all-ceramic restorations.

  1. Emission sensitization processes involving Nd{sup 3+} in YAG

    Energy Technology Data Exchange (ETDEWEB)

    Lupei, V., E-mail: lupei_voicu@yahoo.com [National Institute of Laser, Plasma and Radiation Physics, Bucharest 077125 (Romania); Lupei, A.; Gheorghe, C. [National Institute of Laser, Plasma and Radiation Physics, Bucharest 077125 (Romania); Ikesue, A. [World Lab. Co., Nagoya (Japan)

    2016-02-15

    The paper investigates the characteristics of sensitization processes of Nd{sup 3+} emission in YAG ceramics under broad band pumping by co-doping with Cr{sup 3+} and the prospect of using Nd{sup 3+} and Cr{sup 3+} for sensitization of emission of Yb{sup 3+}. It is evidenced that the energy transfer from Cr{sup 3+} to Nd{sup 3+} involves both direct and weak migration-assisted processes and is thus dependent on the concentrations of both species. It is also found that the ion–ion interaction responsible for the direct transfer contains besides the dipole–dipole coupling strong superexchange contribution that dominates the transfer to the Nd{sup 3+} ions up to the third coordination sphere and has major implication in sensitization. Investigation of (Cr, Nd, Yb)-doped YAG ceramics shows that Cr{sup 3+} can sensitize the emission of Yb{sup 3+} both via the chain Cr–Nd–Yb or by direct Cr–Yb energy transfer. The prospect of utilization of these processes in the solar-pumped laser is discussed. - Highlights: • The efficiency of sensitization increases at high Cr and Nd doping concentrations. • The Cr-to-Nd energy transfer involves both direct and migration-assisted processes. • The direct transfer implies both dipole–dipole and superexchange interactions. • The superexchange interaction has major influence on sensitization. • Sensitized emission of Yb{sup 3+} in (Cr,Nd,Yb):YAG by Cr–Nd–Yb and Cr–Yb transfers.

  2. All solid-state diode pumped Nd:YAG MOPA with stimulated Brillouin phase conjugate mirror

    NARCIS (Netherlands)

    Offerhaus, Herman L.; Godfried, Herman; Godfried, H.P; Witteman, W.J.

    1996-01-01

    At the Nederlands Centrum voor Laser Research (NCLR) a 1 kHz diode-pumped Nd:YAG Master Oscillator Power Amplifier (MOPA) chain with a Stimulated Brillouin Scattering (SBS) Phase Conjugate mirror is designed and operated. A small Brewster angle Nd:YAG slab (2 by 2 by 20 mm) is side pumped with 200

  3. LASIK flap breakthrough in Nd:YAG laser treatment of epithelial ingrowth

    NARCIS (Netherlands)

    Lapid-Gortzak, Ruth; Hughes, John M.; Nieuwendaal, Carla P.; Mourits, Maarten P.; van der Meulen, Ivanka J. E.

    2015-01-01

    To present two cases with complications after Nd:YAG laser treatment of epithelial ingrowth. Case reports. Dense central recurrent epithelial ingrowth was treated with a Nd:YAG laser directed at the epithelial nests in the LASIK flap interface in one case. Misalignment of the aiming beam after

  4. Nd:YAG Lasers Treating of Carious Lesion and Root Canal In Vitro

    Directory of Open Access Journals (Sweden)

    Danqing Xia

    2012-01-01

    Full Text Available Dental caries is a transmissible bacterial disease process, with cavities at the end, and caused by acids from bacterial metabolism. The essence of dental treatment is to clean and disinfect bacterial contamination from the tooth. In this work, we tried to demonstrate the cleaning and disinfecting effects of Nd:YAG laser irradiation on dental carious lesion and root canal in vitro. Acousto-optic Q-switched quasicontinuous and Cr3+:YAG crystal Q-switched pulse Nd:YAG lasers were employed to treat caries lesion and the root canal, respectively. Results showed that acousto-optic Q-switched quasicontinuous Nd:YAG laser irradiation and Cr3+:YAG crystal Q-switched pulse Nd:YAG laser irradiation could rapidly clean decayed material and bacterial contamination from dental carious lesion and the narrow tail end of root canal with minimally invasive in vitro, respectively. It was concluded that acousto-optic Q-switched quasicontinuous laser irradiation may be a rapid and effective alternative caries treatment, and Cr3+:YAG crystal Q-switched pulse Nd:YAG laser irradiation may be an effective method for canal cleaning and disinfecting during root canal therapy.

  5. Successful treatment of acne keloidalis nuchae with erbium:YAG laser: a comparative study.

    Science.gov (United States)

    Gamil, Hend D; Khater, Elsayed M; Khattab, Fathia M; Khalil, Mona A

    2018-05-14

    Acne keloidalis nuchae (AKN) is a chronic inflammatory disease involving hair follicles of the neck. It is a form of keloidal scarring alopecia that is often refractory to medical or surgical management. To evaluate the efficacy of Er:YAG laser in the treatment of AKN as compared to long pulsed Nd:YAG laser. This study was conducted on 30 male patients with AKN. Their ages ranged from 19 to 47 years with a mean age of 36.87 ± 7.8 years. Patients were divided randomly into two groups of 15 patients, each receiving six sessions of either Er:YAG or long-pulsed Nd:YAG laser therapy. A statistically significant decrease in the number of papules was detected at the end of therapy in both groups, with a mean of 91.8% improvement in the Er:YAG group versus 88% in the Nd:YAG group. A significant decrease in plaques count was detected only in the Er: YAG group while a significant decrease in plaques size and consistency was recorded in both groups. The Er: YAG laser proved to be a potentially effective and safe modality both in the early and late AKN lesions.

  6. Shift and broadening of emission lines in Nd 3: YAG laser crystal ...

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 86; Issue 6. Shift and broadening of emission lines in Nd3+:YAG laser crystal influenced by input energy. POURMAND SEYED EBRAHIM REZAEI ... Keywords. Nd3+:YAG crystal; heat generation; three-level emission lines; four-level emission lines; input energy.

  7. Effect of transscleral neodymium: YAG cyclophotocoagulation on intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, P.H.; Gross, R.L.; Koch, D.D. (Baylor College of Medicine, Houston, TX (USA))

    1990-03-01

    A neodymium: YAG laser operating in the thermal mode was used to irradiate isolated intraocular lenses (IOLs) and to perform transscleral cyclophotocoagulation on pseudophakic autopsy eyes to investigate the potential damage to IOL haptics such irradiation may cause. In the isolated IOLs, 70 mJ of energy deformed and partially melted both polymethylmethacrylate (PMMA) and polypropylene haptics. One of the capsular-fixated PC-IOL haptics in an autopsy eye partially melted when irradiated with the maximum energy level (8.8 J), with the aiming beam focused 1 mm posterior to the limbus and maximal posterior focus offset.

  8. Palliation of oesophagogastric neoplasms with Nd:YAG laser treatment

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, S.; Fischerman, K. (Rigshospitalet, Copenhagen (Denmark))

    1990-01-01

    The palliative effect of endoscopic Nd:YAG laser treatment of malignant strictures of the oesophagus and cardia was prospectively evaluated in 30 patients. Most were primarily treated for dysphagia, and swallowing was improved in 21 and normalized in 14 of these patients. Two patients were successfully treated for bleeding. Six patients developed complications (including two perforations), and four of these were fatal. The median survival was four months. It is concluded that in a great number of patients with inoperable cancer of the oesophagus and cardia, laser treatment is better than other palliative procedures. 23 refs., 2 tabs.

  9. Cooperative emission in ion implanted Yb:YAG waveguides

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, G V; Desirena, H; De la Rosa, E [Centro de Investigaciones en Optica, Loma del Bosque 115, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Flores-Romero, E; Rickards, J; Trejo-Luna, R [Instituto de Fisica, UNAM, Apartado Postal 20364, 01000 Mexico, D. F. (Mexico); Marquez, H, E-mail: gvvazquez@cio.mx [Departamento de Optica, CICESE, Km 107 Carr. Tijuana-Ensenada, 22860 Ensenada, B. C. (Mexico)

    2011-01-01

    In this work, we report the analysis of spectroscopic properties of waveguides fabricated by ion implantation in YAG doped with Yb{sup 3+} ions. Three emission bands were detected in the blue, green and red regions under 970-nm excitation. The strong blue-green emission can be explained by a cooperative process between ytterbium ion pairs, leading to emission centered at 514 nm. The additional blue bands as well as green and red emission bands are attributed to the presence of Tm{sup 3+} and Er{sup 3+} traces. The results include absorption and emission curves as well as decay time rates.

  10. Cooperative emission in ion implanted Yb:YAG waveguides

    International Nuclear Information System (INIS)

    Vazquez, G V; Desirena, H; De la Rosa, E; Flores-Romero, E; Rickards, J; Trejo-Luna, R; Marquez, H

    2011-01-01

    In this work, we report the analysis of spectroscopic properties of waveguides fabricated by ion implantation in YAG doped with Yb 3+ ions. Three emission bands were detected in the blue, green and red regions under 970-nm excitation. The strong blue-green emission can be explained by a cooperative process between ytterbium ion pairs, leading to emission centered at 514 nm. The additional blue bands as well as green and red emission bands are attributed to the presence of Tm 3+ and Er 3+ traces. The results include absorption and emission curves as well as decay time rates.

  11. Tapered diode laser pumped 946 nm Nd:YAG laser

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2009-01-01

    We successfully implemented a 946 nm Nd:YAG laser based on a 808 nm tapered diode pump laser. The tapered diode is developed at the Ferdinand-Braun-Institute fur Hochstfrequenztechnik in Germany. Figure 2 shows the experimental setup and results of each pump source coupled into a 1.5 mm crystal...... laser, we show that tapered diode laser pumping potentially increase the power of 946 nm lasers by a factor of two and reduce the threshold by a factor of three....

  12. Treatment of rosacea with long-pulsed Nd: YAG laser

    Directory of Open Access Journals (Sweden)

    Ekin Meşe Say

    2013-03-01

    Full Text Available Background and Design: Rosacea is a chronic inflammatory disorder of the face. There is no curative treatment for the disease. Facial flushing and vascular lesions due to rosacea may significantly affect a patient’s quality of life. Topical and oral antibiotics are not effective for treating rosacea. Currently, laser treatment of vascular lesions has been reported in the literature. We aimed to investigate the efficacy of long-pulse 1064-nm neodymium: YAG (Nd: YAG laser in the treatment of vascular lesions (erythema and telangiectasia in rosacea patients. Materials and Methods: Thirty-nine patients (29 women, 10 men with erythematotelangiectatic rosacea (ETR were recruited into the study. Severity of the disease (ETR-score: 0-3 was assessed for all patients. We used long-pulsed Nd: YAG laser for vascular lesions at 3-4 weeks intervals. The face was divided into seven anatomic regions for evaluation. Assessment was made by comparing pretreatment and posttreatment photographs by using ETR-scores. For evaluating patient satisfaction, a scale of 0 to 3 was used. Results: The patients were divided into three groups according to the ETR scores [ETR-1 (n=12, ETR-2 (n=9, ETR-3 (n=18]. Following an average of 3.95 (2-8 sessions laser treatments, the clinical improvement was statistically significant in all groups (p<0.05. The mean reduction of ETR-score was 91.70% in patients with ETR-1 and. the clinical improvement was to be decreased in severe forms of ETR. The most common sites for the lesions were the malar region, ala nasi and the nasal dorsum, respectively. The lesions on the ala nasi were more recalcitrant to the treatment than those on the other areas. Regarding to physician assessment of treatment’s success, 97% of the patients was associated with moderate and excellent improvement. According to physicians’ assessment, excellent improvement was noticed in 43.58% and, 61.5% of patients reported a high degree of satisfaction with this

  13. Application of YAG laser processing in underwater welding and cutting

    Energy Technology Data Exchange (ETDEWEB)

    Ohwaki, Katsura; Morita, Ichiro; Kojima, Toshio; Sato, Shuichi [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    2002-09-01

    The high-power YAG laser is a new fabrication tool. The laser torch is easy to combine with complex with complex mechanics because of beam delivery through optical fiber. A direct underwater laser welding technology has been developed and applied to the preservation, maintenance and removal of nuclear power plants. For subdividing or removing operations for retirement of plants, the laser cutting properties were confirmed to allow a maximum cutting thickness of 80 mm. For repairing inner surface of stainless steel tanks, an underwater laser welding system using a remote-controlled robot was developed and the high quality of underwater laser welding was confirmed. (author)

  14. Development of YAG laser cutting system for decommissioning nuclear equipments

    International Nuclear Information System (INIS)

    Kasai, Takeshi; Nitta, Kazuhiko; Hosoda, Hiroshi.

    1995-01-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. As a result, the stainless steel plate with a thickness of 22mm could be cut by using an optical fiber which can flexibly propagate laser power, and possibility of application of this laser cutting system to decommissioning nuclear equipments was verified. (author)

  15. Development of YAG laser cutting system for decommissioning nuclear equipments

    Energy Technology Data Exchange (ETDEWEB)

    Kasai, Takeshi [Fuji Electric Co. Research and Development Ltd., Yokosuka, Kanagawa (Japan); Nitta, Kazuhiko; Hosoda, Hiroshi

    1995-07-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. As a result, the stainless steel plate with a thickness of 22mm could be cut by using an optical fiber which can flexibly propagate laser power, and possibility of application of this laser cutting system to decommissioning nuclear equipments was verified. (author).

  16. Strategie Elektronického obchodu firmy

    OpenAIRE

    Gašpar, Petr

    2011-01-01

    Moje bakalářská práce se bude zabývat volbou vhodnou strategie pro vybudování elektronického obchodu maloobchodní firmy. V práci se zaměřím na to jak docílit aby firma rozšířila své působení na trhu a to právě pomocí elektronického obchodu. Dále budu ve své práci taky mapovat současnou situaci problematiky elektronických obchodů. Analyzuji trh, konkurenci a na základě těchto údajů zvolím strategii, aby elektronický obchod prosperoval. V praktické části se potom zaměřím na maloobchodní firmu J...

  17. Er:YAG and CTH:YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement

    International Nuclear Information System (INIS)

    Buckova, M; Kasparova, M; Dostalova, T; Jelinkova, H; Sulc, J; Nemec, M; Fibrich, M; Bradna, P; Miyagi, M

    2013-01-01

    Laser radiation can be used for effective caries removal and cavity preparation without significant thermal effects, collateral damage of tooth structure, or patient discomfort. The aim of this study was to compare the quality of tissue after contact or non-contact Er:YAG and CTH:YAG laser radiation ablation. The second goal was to increase the sealing ability of hard dental tissues using sonic-activated bulk filling material with change in viscosity during processing. The artificial caries was prepared in intact teeth to simulate a demineralized surface and then the Er:YAG or CTH:YAG laser radiation was applied. The enamel artificial caries was gently removed by the laser radiation and sonic-activated composite fillings were inserted. A stereomicroscope and then a scanning electron microscope were used to evaluate the enamel surface. Er:YAG contact mode ablation in enamel was quick and precise; the cavity was smooth with a keyhole shaped prism and rod relief arrangement without a smear layer. The sonic-activated filling material was consistently regularly distributed; no cracks or microleakage in the enamel were observed. CTH:YAG irradiation was able to clean but not ablate the enamel surface; in contact and also in non-contact mode there was evidence of melting and fusing of the enamel. (paper)

  18. Er:YAG and CTH:YAG laser radiation: contact versus non-contact enamel ablation and sonic-activated bulk composite placement

    Science.gov (United States)

    Buckova, M.; Kasparova, M.; Dostalova, T.; Jelinkova, H.; Sulc, J.; Nemec, M.; Fibrich, M.; Bradna, P.; Miyagi, M.

    2013-05-01

    Laser radiation can be used for effective caries removal and cavity preparation without significant thermal effects, collateral damage of tooth structure, or patient discomfort. The aim of this study was to compare the quality of tissue after contact or non-contact Er:YAG and CTH:YAG laser radiation ablation. The second goal was to increase the sealing ability of hard dental tissues using sonic-activated bulk filling material with change in viscosity during processing. The artificial caries was prepared in intact teeth to simulate a demineralized surface and then the Er:YAG or CTH:YAG laser radiation was applied. The enamel artificial caries was gently removed by the laser radiation and sonic-activated composite fillings were inserted. A stereomicroscope and then a scanning electron microscope were used to evaluate the enamel surface. Er:YAG contact mode ablation in enamel was quick and precise; the cavity was smooth with a keyhole shaped prism and rod relief arrangement without a smear layer. The sonic-activated filling material was consistently regularly distributed; no cracks or microleakage in the enamel were observed. CTH:YAG irradiation was able to clean but not ablate the enamel surface; in contact and also in non-contact mode there was evidence of melting and fusing of the enamel.

  19. Thermal effects associated with the Nd/YAG dental laser.

    Science.gov (United States)

    von Fraunhofer, J A; Allen, D J

    1993-01-01

    The heat produced at the dentinal pulpal wall opposite the irradiation site was measured during etching of dental enamel with an Nd:YAG laser in preparation for direct bonding of orthodontic appliances. Forty extracted human teeth were randomly divided into four groups of 10 teeth. Within each group, the buccal surfaces of 5 teeth and the lingual surfaces of the other 5 teeth were laser treated for 12 sec. Irradiation was performed with a commercial Nd:YAG laser at the power settings of 80mJ, 1W, 2W and 3W. Prior to irradiation, an occlusal access preparation was made into the pulp in order to facilitate the placement of a thermocouple for measurement of temperature changes at the dentinal pulpal wall opposite the irradiation site. The thermocouple was held against the dentinal pulpal wall and the resulting temperature changes were recorded. Heating effects at the dentinal pulpal wall on both buccal and lingual surfaces showed an increase in heat as a function of the increase in power output from the laser unit (p damage to the pulp tissue immediately opposite the site of laser irradiation.

  20. Dynamics of pulsed holmium:YAG laser photocoagulation of albumen

    International Nuclear Information System (INIS)

    Pfefer, T.J.; Welch, A.J.

    2000-01-01

    The pulsed holmium:YAG laser (λ = 2.12 μm, τ p = 250 μs) has been investigated as a method for inducing localized coagulation for medical procedures, yet the dynamics of this process are not well understood. In this study, photocoagulation of albumen (egg white) was analysed experimentally and results compared with optical-thermal simulations to investigate a rate process approach to thermal damage and the role of heat conduction and dynamic changes in absorption. The coagulation threshold was determined using probit analysis, and coagulum dynamics were documented with fast flash photography. The nonlinear computational model, which included a Beer's law optical component, a finite difference heat transfer component and an Arrhenius equation-based damage calculation, was verified against data from the literature. Moderate discrepancies between simulation results and our experimental data probably resulted from the use of a laser beam with an irregular spatial profile. This profile produced a lower than expected coagulation threshold and an irregular damage distribution within a millisecond after laser onset. After 1 ms, heat conduction led to smoothing of the coagulum. Simulations indicated that dynamic changes in absorption led to a reduction in surface temperatures. The Arrhenius equation was shown to be effective for simulating transient albumen coagulation during pulsed holmium:YAG laser irradiation. Greater understanding of pulsed laser-tissue interactions may lead to improved treatment outcome and optimization of laser parameters for a variety of medical procedures. (author)

  1. Nd:YAG laser in art works restoration

    Directory of Open Access Journals (Sweden)

    Flores, T.

    1998-04-01

    Full Text Available Laser cleaning in works of art has a number of advantages over traditional techniques of restoration. In this article, the technique used and the physical mechanisms that explain the process of ablation of pollutants are described. The results obtained in the cleaning of statues of marble and alabaster are exposed as well as oil-painting restoration. In this last specific case, the Nd:YAG laser is used with successful results.

    La limpieza de obras de arte por láser presenta una serie de ventajas sobre técnicas tradicionales de restauración. En el presente trabajo se describen la técnica empleada y los mecanismos físicos que explican el proceso de ablación de contaminantes. Se reportan los resultados alcanzados en la limpieza de estatuas de mármol y alabastro, así como en la restauración de pintura al óleo. En este último caso, se emplea por primera vez el láser de Nd:YAG con resultados ventajosos.

  2. YAG laser cladding to heat exchanger flange in actual plant

    International Nuclear Information System (INIS)

    Toshio, Kojima

    2001-01-01

    This paper is a sequel to ''Development of YAG Laser Cladding Technology to Heat Exchanger Flange'' presented in ICONE-8. A YAG Laser cladding technology is a permanent repairing and preventive maintenance method for heat exchanger's flange (channel side) seating surface which is degraded by the corrosion in long term operation. The material of this flange is carbon steel, and that of cladding wire is type 316 stainless steel so as to have high corrosion resistance. In former paper above, the soundness of cladding layers were presented to be verified. This channel side flange is bolted with tube sheet (shell side) through metal gasket. As the tube sheet side is already cladded a corrosion resistant material, it needs to apply the repairing and preventive maintenance method to only channel side. In 2000 this technology had been performed to the actual heat exchanger (Residual Heat Removal Heat Exchanger; RHR Hx) flange in domestic nuclear power plant. This paper described the outline, special equipment, and our total evaluation for this actual laser cladding work. And also several technical subjects which we should solve and/or improve for the next project was presented. (author)

  3. Development of underwater YAG laser repair welding robots for tanks

    International Nuclear Information System (INIS)

    Miwa, Yasuhiro; Satoh, Syuichi; Ito, Kosuke; Kochi, Tsutomu; Kojima, Toshio; Ohwaki, Katsura; Morita, Ichiro

    1999-01-01

    A remote-controlled repair welding robot which uses YAG laser welding technology in underwater environment was developed. This is an underwater robot technology combined with a laser welding technology. This report will describe the structure and performance of this robot, and the welding test results. The repair welding robot consists of two parts. The one is driving equipment, and the other is welding unit. It can swim in the tank, move around the tank wall, and stay on the welding area. After that it starts YAG laser repair welding. The target of this technology is inner surface repair of some tanks made of austenitic stainless steel, for example RW (Radioactive Waste) tanks. A degradation by General Corrosion and so on might be occurred at inner surface of these tanks in BWR type nuclear power plants. If the damaged area is wide, repair welding works are done. Some workers go into the tank and set up scaffolding after full drainage. In many cases it spends too much time for draining water and repair welding preparation. If the repair welding works can be done in underwater environment, the outage period will be reduced. This is a great advantage. (author)

  4. Heterogeneous Uptake of HO2 Radicals onto Atmospheric Aerosols

    Science.gov (United States)

    George, I. J.; Matthews, P. S.; Brooks, B.; Goddard, A.; Whalley, L. K.; Baeza-Romero, M. T.; Heard, D. E.

    2011-12-01

    The hydroxyl (OH) and hydroperoxyl (HO2) radicals, together known as HOx, play a vital role in atmospheric chemistry by controlling the oxidative capacity of the troposphere. The atmospheric lifetime and concentrations of many trace reactive species, such as volatile organic compounds (VOCs), are determined by HOx radical levels. Therefore, the ability to accurately predict atmospheric HOx concentrations from a detailed knowledge of their sources and sinks is a very useful diagnostic tool to assess our current understanding of atmospheric chemistry. Several recent field studies have observed significantly lower concentrations of HO2 radicals than predicted using box models, where HO2 loss onto aerosols was suggested as a possible missing sink [1, 2]. However, the mechanism on HO2 uptake onto aerosols and its impact on ambient HOx levels are currently not well understood. To improve our understanding of this process, we have conducted laboratory experiments to measure HO2 uptake coefficients onto submicron aerosol particles. The FAGE (Fluorescence Assay by Gas Expansion) technique, a highly sensitive laser induced fluorescence based detection method, was used to monitor HO2 uptake kinetics onto aerosol particles in an aerosol flow tube. The application of the FAGE technique allowed for kinetic experiments to be performed under low HO2 concentrations, i.e. [HO2] atomizing dilute salt solutions or by homogeneous nucleation. HO2 uptake coefficients (γ) have been measured for single-component solid and aqueous inorganic salt and organic aerosol particles with a wide range of hygroscopicities. HO2 uptake coefficients on solid particles were below the detection limit (γ < 0.001), whereas on aqueous aerosols uptake coefficients were somewhat larger (γ = 0.001 - 0.008). HO2 uptake coefficients were highest on aerosols containing metal ions, such as Cu and Fe. Humidity and aerosol pH did not significantly impact the reactive HO2 uptake. Preliminary experiments have also

  5. Growth, optical and EPR studies of {sup 151}Eu{sup 2+}:YAG single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Petrosyan, A.G., E-mail: pet@ipr.sci.am [Institute for Physical Research, National Academy of Sciences, Ashtarak, 0203 (Armenia); Asatryan, H.R. [Ioffe Physical-Technical Institute, Politekhnicheskaya ul. 26, St. Petersburg, 194021 (Russian Federation); Hovhannesyan, K.L.; Derdzyan, M.V. [Institute for Physical Research, National Academy of Sciences, Ashtarak, 0203 (Armenia); Feofilov, S.P. [Ioffe Physical-Technical Institute, Politekhnicheskaya ul. 26, St. Petersburg, 194021 (Russian Federation); Eganyan, A.V.; Sargsyan, R.S. [Institute for Physical Research, National Academy of Sciences, Ashtarak, 0203 (Armenia)

    2017-01-01

    Single crystals of {sup 151}Eu:YAG were grown by the vertical Bridgman method using Eu{sub 2}O{sub 3} with isotopic enrichment of {sup 151}Eu of 97.5%. Additional Hf{sup 4+}or Si{sup 4+} ions were introduced to favor a high concentrations of Eu{sup 2+}. As compared to Eu:YAG with natural isotope composition, the EPR spectra of YAG doped with {sup 151}Eu isotope show a reduced number of hyperfine structure components and a well-resolved structure of a bigger number of electronic transitions. Optical properties of obtained crystals and the effects of heat treatments under oxidizing and reducing conditions are reported. Based on the analysis of Eu{sup 3+} distribution in oxidized Eu,Hf:YAG, in comparison to that in Eu:YAG, the concentration of Eu{sup 2+} in as-grown Eu,Hf:YAG is determined. - Highlights: • YAG:Eu,Hf single crystals containing only {sup 151}Eu isotopes were prepared. • isotopic enriched crystals gave a well-resolved EPR hyperfine structure of Eu{sup 2+} centers. • the redox ratio was followed through the Eu{sup 2+} associated absorption band at 250 nm. • the band intensities at 378 nm correlate with the Eu{sup 2+} concentration.

  6. HoCaMA: Home Care Hybrid Multiagent Architecture

    Science.gov (United States)

    Fraile, Juan A.; Bajo, Javier; Abraham, Ajith; Corchado, Juan M.

    Home Care is one of the main objectives of Ambient Intelligence. Nowadays, the disabled and elderly population, which represents a significant part of our society, requires novel solutions for providing home care in an effective way. In this chapter, we present HoCaMA, a hybrid multiagent architecture that facilitates remote monitoring and care services for disabled patients at their homes. HoCaMA combines multiagent systems and Web services to facilitate the communication and integration with multiple health care systems. In addition, HoCaMA focuses on the design of reactive agents capable of interacting with different sensors present in the environment, and incorporates a system of alerts through SMS and MMS mobile technologies. Finally, it uses Radio Frequency IDentification and JavaCard technologies to provide advanced location and identification systems, as well as automatic access control facilities. HoCaMA has been implemented in a real environment and the results obtained are presented within this chapter.

  7. Synthesis of highly sinterable YAG nanopowders by a modified co-precipitation method

    International Nuclear Information System (INIS)

    Chen, Zhi-Hui; Yang, Yun; Hu, Zhang-Gui; Li, Jiang-Tao; He, Shu-Li

    2007-01-01

    A hydrate precursor of yttrium aluminum garnet (YAG) was synthesized by a modified co-precipitation method, in which n-butanol was employed as a low-cost recyclable dehydration solvent. A mixed solution of ethanol and ammonia were used as precipitant. Pure YAG phase appeared after the as-prepared precursors being calcined at 850 o C for 2 h. The nanocrystalline YAG particles calcined at 1100 o C were well dispersed with average diameter of about 40 nm, which can be densified to transparency under vacuum sintering at 1700 o C for 5 h with TEOS as sintering additive

  8. Improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser

    Science.gov (United States)

    Bao, Xiao-qing; Zhu, Jing; Shi, Hong-Min

    2005-07-01

    Objective: To observe and study the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser and evaluate the effective rate. Methods: 60 patients of internal hemorrhoids were treated with Nd:YAG laser (10-15mw) irradiating on the mucosa of the lesions. Results: Among 60 patients, 57 patients were primarily cured with one treatment, 3 patients were primarily cured with two treatments. The effective rate was 95% with one treatment, and it reached to 100% with two treatments. Conclusions: the improvement of the technique in treatment of internal hemorrhoids with Nd:YAG laser is effective and easy to operate.

  9. New pulsed YAG laser performances in cutting thick metallic materials for nuclear applications

    International Nuclear Information System (INIS)

    Alfille, J.P.; Prunele, D. de; Pilot, G.

    1996-01-01

    The purpose of this study was to evaluate the capacities of the pulsed YAG laser thick cutting on metallic material and to compare with the CO 2 laser capacities. Stainless steel (304L) cutting tests were made in air and underwater using CO 2 and YAG lasers. A performance assessment was made for each laser and the wastes produced in the cutting operation were measured and the gases and the aerosols analyzed. The results show that the pulsed YAG laser is high performance tool for thick cutting and particularly attractive for nuclear applications

  10. Time-resolved luminescent spectroscopy of YAG:Ce single crystal and single crystalline films

    International Nuclear Information System (INIS)

    Zorenko, Yu.; Gorbenko, V.; Savchyn, V.; Vozniak, T.; Puzikov, V.; Danko, A.; Nizhankovski, S.

    2010-01-01

    The peculiarities of the luminescence and energy transfer from YAG host to the emission centers formed by the Y Al antisite defects and Ce 3+ ions have been studied in YAG:Ce single crystals, grown from the melt by modified Bridgman method in Ar and CO 2 + H 2 atmospheres, and YAG:Ce single crystalline film, grown by liquid phase epitaxy method, using the comparative time-resolved luminescent spectroscopy under excitation by synchrotron radiation in the range of fundamental adsorption of this garnet.

  11. In vitro studies with a pulsed neodymium/YAG laser.

    Science.gov (United States)

    Venkatesh, S; Guthrie, S; Foulds, W S; Lee, W R; Cruickshank, F R; Bailey, R T

    1985-02-01

    The relationships between the destructive effects of Q-switched Nd/YAG laser pulses and a number of experimental parameters were studied for various target materials including in particular excised, fixed samples of human trabecular meshwork. The laser parameters altered were the pulse energy, the convergence angle of the focused beam, and the position of the focus of the beam relative to the target's axial position. The main finding was that it was possible to make deep holes, of a diameter less than 100 micron, in virtually transparent samples of trabecular meshwork with a laser delivery system of 6 degrees convergence and pulse energies of 14 mJ or more. The relevance of this and the other experimental results to the development of a reliable system for performing internal trabeculotomies for the treatment of open-angle glaucoma is presented.

  12. Use of the holmium:YAG laser in urology

    Science.gov (United States)

    Mattioli, Stefano

    1997-12-01

    The Holmium-YAG is a versatile laser with multiple soft- tissue applications including tissue incision and vaporization, and pulsed-laser applications such as lithotripsy. At 2140 nanometers, the wavelength is highly absorbed by tissue water. Further, like CO2 laser, the Holmium produces immediate tissue vaporization while minimizing deep thermal damage to surrounding tissues. It is an excellent instrument for endopyelotomy, internal urethrotomy, bladder neck incisions and it can be used to resect the prostate. The Holmium creates an acute TUR defect which gives immediate results like the TURP. More than 50 patients were treated from Jan. 1996 to Jan. 1997 for obstructive symptoms due to benign prostatic hyperplasia, bladder neck stricture, urethral stenosis, and superficial bladder tumors.

  13. Numerical simulation of a battlefield Nd:YAG laser

    Science.gov (United States)

    Henriksson, Markus; Sjoqvist, Lars; Uhrwing, Thomas

    2005-11-01

    A numeric model has been developed to identify the critical components and parameters in improving the output beam quality of a flashlamp pumped Q-switched Nd:YAG laser with a folded Porro-prism resonator and polarization output coupling. The heating of the laser material and accompanying thermo-optical effects are calculated using the finite element partial differential equations package FEMLAB allowing arbitrary geometries and time distributions. The laser gain and the cavity are modeled with the physical optics simulation code GLAD including effects such as gain profile, thermal lensing and stress-induced birefringence, the Pockels cell rise-time and component aberrations. The model is intended to optimize the pumping process of an OPO providing radiation to be used for ranging, imaging or optical countermeasures.

  14. Er:YAG laser for endodontics: efficiency and safety

    Science.gov (United States)

    Hibst, Raimund; Stock, Karl; Gall, Robert; Keller, Ulrich

    1997-12-01

    Recently it has been shown that bacterias can be sterilized by Er:YAG laser irradiation. By optical fiber transmission the bactericidal effect can also be used in endodontics. In order to explore potential laser parameters, we further investigated sterilization of caries and measured temperatures in models simulating endodontic treatment. It was found out that the bactericidal effect is cumulative, with single pulses being active. This offers to choose all laser parameters except pulse energy (radiant exposure) from technical, practical or safety considerations. For clinical studies the following parameter set is proposed for efficient and safe application (teeth with a root wall thickness > 1 mm, and prepared up to ISO 50): pulse energy: 50 mJ, repetition rate: 15 Hz, fiber withdrawal velocity: 2 mm/s. With these settings 4 passes must be performed to accumulate the total dose for sterilization.

  15. Single, composite, and ceramic Nd:YAG 946-nm lasers

    Science.gov (United States)

    Lan, Rui-Jun; Yang, Guang; Zheng-Ping, Wang

    2015-06-01

    Single, composite crystal and ceramic continuous wave (CW) 946-nm Nd:YAG lasers are demonstrated, respectively. The ceramic laser behaves better than the crystal laser. With 5-mm long ceramic, a CW output power of 1.46 W is generated with an optical conversion efficiency of 13.9%, while the slope efficiency is 17.9%. The optimal ceramic length for a 946-nm laser is also calculated. Project supported by the National Natural Science Foundation of China (Grant No. 61405171), the Natural Science Foundation of Shandong Province, China (Grant No. ZR2012FQ014), and the Science and Technology Program of the Shandong Higher Education Institutions of China (Grant No. J13LJ05).

  16. Precision cutting and drilling with the Nd-YAG laser

    International Nuclear Information System (INIS)

    Lingenfelter, A.C.; Anglin, C.D.; Westrich, C.N.; Murchie, J.R.

    1986-01-01

    The Laser Processing Facility of the Materials Fabrication Division of Lawrence Livermore National Laboratory has two pulsed Nd-YAG lasers mounted on machine tool bases. Over the years the authors have had requirements for cutting a wide variety of materials, frequently to very tight dimensional tolerances. They have found that the laser process is particularly well suited for two application areas; (1) for thin cross sections of most all materials, and (2) for refractory metals and ceramics such as tungsten, tantalum, and molybdenum, silicon wafers, alumina, and graphite foil. Some of these materials are difficult if not impossible to cut and drill in any other manner. Examples of each of these types of applications are sighted. Data are presented to illustrate the effects and interactions of laser parameter variables such as aperturing, choice of lenses, focus, pulse length, and energy level. Examples of applications are shown

  17. Intelligent monitoring of YAG laser welding on steam generator tubes

    International Nuclear Information System (INIS)

    Hosaka, Shigetaka; Nagura, Yasumi; Ishide, Takashi; Nagashima, Tadashi; Akaba, Takashi

    1992-01-01

    The 'KASHIKOKI' intelligent device for monitoring the YAG laser welding of steam generator tubes is described in this paper. The 'KASHIKOKI', it monitors the series of six channels, for example, the reflected laser beam and the welding speed, etc. It learns the normal criteria and the anomalous criteria of welding, and discriminates between normal and anomalous welding using the learned criteria, and distinguishes the anomaly into several types. As the results of evaluation test, the degree of correspondence between this device and an expert is about 90%. This paper describes the new methods the multi-variate analysis model for discriminating between normal and anomalous welding, and a neural network model for distinguishing the types of anomaly. (author)

  18. Segmental irradiation of the bladder with neodymium YAG laser irradiation

    International Nuclear Information System (INIS)

    McPhee, M.S.; Mador, D.R.; Tulip, J.; Ritchie, B.; Moore, R.; Lakey, W.H.

    1982-01-01

    The Neodymium YAG laser energy source can be readily adapted for cystoscopic use by some simple modifications of existing urologic equipment. Both the fiberoptic resectoscope and a deflecting cystourethroscope have been adapted for this purpose. Fixation of the fiber tip 1 cm. from the target and use of a divergent beam of 36 degrees allows the delivery of standardized dosage to a relatively large bladder tissue volume. Animal experiments involving 35 mongrel dogs established that repetitive overlapping doses of 200 joules ech can successfully treat a large area of bladder resulting in a full thickness bladder wall injury. This technique has been used in 4 high risk patients with infiltrating bladder cancer without adverse sequelae. The ability to reliably produce a full thickness lesion may give this modality a therapeutic advantage over conventional cautery techniques especially for the treatment of residual infiltrative carcinoma

  19. High-average-power diode-pumped Yb: YAG lasers

    International Nuclear Information System (INIS)

    Avizonis, P V; Beach, R; Bibeau, C M; Emanuel, M A; Harris, D G; Honea, E C; Monroe, R S; Payne, S A; Skidmore, J A; Sutton, S B

    1999-01-01

    A scaleable diode end-pumping technology for high-average-power slab and rod lasers has been under development for the past several years at Lawrence Livermore National Laboratory (LLNL). This technology has particular application to high average power Yb:YAG lasers that utilize a rod configured gain element. Previously, this rod configured approach has achieved average output powers in a single 5 cm long by 2 mm diameter Yb:YAG rod of 430 W cw and 280 W q-switched. High beam quality (M(sup 2)= 2.4) q-switched operation has also been demonstrated at over 180 W of average output power. More recently, using a dual rod configuration consisting of two, 5 cm long by 2 mm diameter laser rods with birefringence compensation, we have achieved 1080 W of cw output with an M(sup 2) value of 13.5 at an optical-to-optical conversion efficiency of 27.5%. With the same dual rod laser operated in a q-switched mode, we have also demonstrated 532 W of average power with an M(sup 2) and lt; 2.5 at 17% optical-to-optical conversion efficiency. These q-switched results were obtained at a 10 kHz repetition rate and resulted in 77 nsec pulse durations. These improved levels of operational performance have been achieved as a result of technology advancements made in several areas that will be covered in this manuscript. These enhancements to our architecture include: (1) Hollow lens ducts that enable the use of advanced cavity architectures permitting birefringence compensation and the ability to run in large aperture-filling near-diffraction-limited modes. (2) Compound laser rods with flanged-nonabsorbing-endcaps fabricated by diffusion bonding. (3) Techniques for suppressing amplified spontaneous emission (ASE) and parasitics in the polished barrel rods

  20. Noncontact Er:YAG laser ablation: clinical evaluation.

    Science.gov (United States)

    Dostálová, T; Jelínková, H; Kucerová, H; Krejsa, O; Hamal, K; Kubelka, J; Procházka, S

    1998-10-01

    The aim of this study is to evaluate the quality of laser ablation in comparison with the classical drilling preparation. For the experiment, the Er:YAG laser drilling machine was used. The system had a laser head, water cooler, and power supply with automatic control. Spot size of 300-350 microns was used for the preparation. Repetition rate of 1-4 Hz, and pulse energies of 100-400 mJ with water spray were chosen. Cavity shape in comparison with classical drill, time of preparation, and influence of cavity shape on filling materials retention in accordance with the U.S. Public Health Service System were used. The evaluation criteria for noncontact Er:YAG ablation were done. The cavity shape is irregular, but spot surface has larger area and microretentive appearance. Caries of enamel and dentin were treated with a noncontact preparation. It was possible to remove the old insufficient fillings, except for amalgam or metal alloys. The average number of pulses was 111.22 (SE 67.57). Vibrations of microexplosions during preparation were felt by patients on 14 cavities; however, nobody felt unpleasant pain. The qualities of filling materials in laser cavities were very stable; however, cavo surface margin discoloration of 82-86% of Alfa rating could be a problem. Changes of the color and anatomic form of the tooth were observed in 4-8%. In comparison with the classical treatment, it could be said that the retention and quality of filling materials is the same or very similar.

  1. Návrh ubytovacího rezervačního internetového portálu

    OpenAIRE

    Čurilla, Miroslav

    2010-01-01

    Táto diplomová práca sa zaoberá návrhom ubytovacieho rezervačného internetového portálu. Cieľom práce je navrhnutie systému rezervovania ubytovania v ubytovacích zariadenia optimálnym spôsobom. Vedľajšími cieľmi je navrhnutie hardvérových, softvérových, bezpečnostných, marketingových a ekonomických riešení pri návrhu ubytovacieho rezervačné internetového portálu. This master’s thesis deals with the design of the internet portal for the reservation of accommodation. Its objective is the pro...

  2. Magnetic state controllable critical temperature in epitaxial Ho/Nb bilayers

    Directory of Open Access Journals (Sweden)

    Yuanzhou Gu

    2014-04-01

    Full Text Available We study the magnetic properties of Ho thin films with different crystallinity (either epitaxial or non-epitaxial and investigate their proximity effects with Nb thin films. Magnetic measurements show that epitaxial Ho has large anisotropy in two different crystal directions in contrast to non-epitaxial Ho. Transport measurements show that the superconducting transition temperature (Tc of Nb thin films can be significantly suppressed at zero field by epitaxial Ho compared with non-epitaxial Ho. We also demonstrate a direct control over Tc by changing the magnetic states of the epitaxial Ho layer, and attribute the strong proximity effects to exchange interaction.

  3. Výložník kombinovaného skládkového stroje

    OpenAIRE

    Štursa, Martin

    2013-01-01

    Tato diplomová práce se zabývá konstrukcí částí kombinovaného skládkového stroje určeného pro obsluhu skládky hnědého uhlí u uhelné elektrárny. Nejprve jsou nadefinovány základní parametry stroje a silové účinky zatěžující stroj během provozu. Práce dále obsahuje návrh ocelové konstrukce kolesového výložníku, kolesa, korečků, pohonu kolesa, hřídele, ložisek a dalších částí kolesového výložníku. Tyto součásti jsou ověřeny analytickými nebo konečnoprvkovými výpočty. This master’s thesis deal...

  4. Continuous-wave ceramic Nd:YAG laser at 1123 nm

    International Nuclear Information System (INIS)

    Zhang, S S; Wang, Q P; Zhang, X Y; Cong, Z H; Fan, S Z; Liu, Z J; Sun, W J

    2009-01-01

    Ceramic Nd:YAG (cNd:YAG) materials are employed to generate 1123-nm laser. A fiber-coupled continuous-wave (CW) 808-nm diode laser is used as the pumping source. With an incident diode power of 26.1 W, a CW output power of up to 10.8 W is obtained with a 10-mm-long ceramic Nd:YAG rod (1.0 at.%-Nd-doped). The conversion efficiency from diode power to 1123-nm laser power is 41.4%. The laser performance of another 10-mm-long cNd:YAG rod with a Nd-doping concentration of 0.6 at.% is studied as a comparison

  5. Continuous production of phosphor YAG:Tb nanoparticles by hydrothermal synthesis in supercritical water

    International Nuclear Information System (INIS)

    Hakuta, Yukiya; Haganuma, Tsukasa; Sue, Kiwamu; Adschiri, Tadafumi; Arai, Kunio

    2003-01-01

    Phosphor YAG:Tb ((Y 2.7 Tb 0.3 )Al 5 O 12 ) nano particles were synthesized by a hydrothermal method at supercritical conditions (400 deg. C and 30 MPa) using a flow reactor. Hydroxide sol solutions formed by stoichiometric aluminum nitrate, yttrium nitrate, terbium nitrate and potassium hydroxide solutions. The relationship between particle size and experimental variables including pH, concentration of coexistent ions and hydroxide sol were investigated. Particles were characterized by XRD, TEM and photo-luminescence measurements. Particle size of YAG:Tb became finer as pH was increased or potassium nitrate concentration of the starting metal salt solution was increased. By removing the coexisting ions (NO 3 - , K + ) from the metal salt solution, single phase YAG:Tb particles with 20 nm particle size were obtained. The emission spectra of YAG:Tb particles of 14 nm shows a blue shift

  6. Luminescence and scintillation properties of YAG:Ce single crystal and optical ceramics

    CERN Document Server

    Mihóková, E; Mareš, J A; Beitlerová, A; Vedda, A; Nejezchleb, K; Blažek, K; D’Ambrosio, C

    2007-01-01

    We use various techniques to study optical and scintillation properties of Ce-doped yttrium aluminum garnet, Y3Al5O12 (YAG:Ce), in the form of a high-quality industrial single crystal. This was compared to optical ceramics prepared from YAG:Ce nanopowders. We present experimental data in the areas of optical absorption, radioluminescence, scintillation decay, photoelectron yield, thermally stimulated luminescence and radiation-induced absorption. The results point to an interesting feature—the absence of antisite (YAl, i.e. Y at the Al site) defects in optical ceramics. The scintillation decay of the ceramics is faster than that of the single crystal, but its photoelectron yield (measured with 1 μs integration time) is about 30–40% lower. Apart from the photoelectron yield value the YAG:Ce optical ceramic is fully comparable to a high quality industrial YAG:Ce single crystal and can become a competitive scintillator material.

  7. Diode pumped 1kHz high power Nd:YAG laser with excellent beam quality

    NARCIS (Netherlands)

    Godfried, Herman; Godfried, H.P; Offerhaus, Herman L.

    1997-01-01

    The design and operation of a one kilohertz diode pumped all solid-state Nd:YAG master oscillator power amplifier system with a phase conjugate mirror is presented. The setup allows high power scaling without reduction in beam quality.

  8. High energy single frequency Yb:YAG crystalline fiber waveguide master oscillator power amplifier, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall objective is to demonstrate the concept of Yb:YAG crystalline fiber MOPA laser and investigation the technical feasibility toward 50 mJ single frequency...

  9. The electron capture in 163Ho experiment - ECHo

    Science.gov (United States)

    Gastaldo, L.; Blaum, K.; Chrysalidis, K.; Day Goodacre, T.; Domula, A.; Door, M.; Dorrer, H.; Düllmann, Ch. E.; Eberhardt, K.; Eliseev, S.; Enss, C.; Faessler, A.; Filianin, P.; Fleischmann, A.; Fonnesu, D.; Gamer, L.; Haas, R.; Hassel, C.; Hengstler, D.; Jochum, J.; Johnston, K.; Kebschull, U.; Kempf, S.; Kieck, T.; Köster, U.; Lahiri, S.; Maiti, M.; Mantegazzini, F.; Marsh, B.; Neroutsos, P.; Novikov, Yu. N.; Ranitzsch, P. C. O.; Rothe, S.; Rischka, A.; Saenz, A.; Sander, O.; Schneider, F.; Scholl, S.; Schüssler, R. X.; Schweiger, Ch.; Simkovic, F.; Stora, T.; Szücs, Z.; Türler, A.; Veinhard, M.; Weber, M.; Wegner, M.; Wendt, K.; Zuber, K.

    2017-06-01

    Neutrinos, and in particular their tiny but non-vanishing masses, can be considered one of the doors towards physics beyond the Standard Model. Precision measurements of the kinematics of weak interactions, in particular of the 3H β-decay and the 163Ho electron capture (EC), represent the only model independent approach to determine the absolute scale of neutrino masses. The electron capture in 163Ho experiment, ECHo, is designed to reach sub-eV sensitivity on the electron neutrino mass by means of the analysis of the calorimetrically measured electron capture spectrum of the nuclide 163Ho. The maximum energy available for this decay, about 2.8 keV, constrains the type of detectors that can be used. Arrays of low temperature metallic magnetic calorimeters (MMCs) are being developed to measure the 163Ho EC spectrum with energy resolution below 3 eV FWHM and with a time resolution below 1 μs. To achieve the sub-eV sensitivity on the electron neutrino mass, together with the detector optimization, the availability of large ultra-pure 163Ho samples, the identification and suppression of background sources as well as the precise parametrization of the 163Ho EC spectrum are of utmost importance. The high-energy resolution 163Ho spectra measured with the first MMC prototypes with ion-implanted 163Ho set the basis for the ECHo experiment. We describe the conceptual design of ECHo and motivate the strategies we have adopted to carry on the present medium scale experiment, ECHo-1K. In this experiment, the use of 1 kBq 163Ho will allow to reach a neutrino mass sensitivity below 10 eV/ c 2. We then discuss how the results being achieved in ECHo-1k will guide the design of the next stage of the ECHo experiment, ECHo-1M, where a source of the order of 1 MBq 163Ho embedded in large MMCs arrays will allow to reach sub-eV sensitivity on the electron neutrino mass.

  10. Simultaneous synthesis and densification of transparent, photoluminescent polycrystalline YAG by current activated pressure assisted densification (CAPAD)

    Energy Technology Data Exchange (ETDEWEB)

    Penilla, E.H.; Kodera, Y. [Mechanical Engineering Dept., Materials Science and Engineering Program, University of California, Riverside (United States); Garay, J.E., E-mail: jegaray@engr.ucr.edu [Mechanical Engineering Dept., Materials Science and Engineering Program, University of California, Riverside (United States)

    2012-08-20

    Highlights: Black-Right-Pointing-Pointer We report a method for the synthesis of transparent and PL bulk polycrystalline Ce:YAG using CAPAD. Black-Right-Pointing-Pointer The process uses {gamma}-Al{sub 2}O{sub 3}, Y{sub 2}O{sub 3}, and CeO{sub 2} nanopowders, reacted and densified simultaneously. Black-Right-Pointing-Pointer The synthesis/densification kinetics are faster than those reported previously. Black-Right-Pointing-Pointer Optical measurements show good transparency in the visible and photoluminescence (PL) in the Ce:YAG. Black-Right-Pointing-Pointer The PL peak is broad and appears white when excited using blue light. - Abstract: We report a method for the synthesis and processing of transparent bulk polycrystalline yttrium aluminum garnet (YAG) and photoluminescent Ce-doped YAG ceramics via solid-state reactive-current activated pressure assisted densification (CAPAD). The process uses commercially available {gamma}-Al{sub 2}O{sub 3}, Y{sub 2}O{sub 3}, and CeO{sub 2} nanopowders. The nanopowders were reacted and densified simultaneously at temperatures between 850 Degree-Sign C and 1550 Degree-Sign C and at a maximum pressure of 105 MPa. The solid-state reaction to phase pure YAG occurs in under 4 min at processing temperatures 1100 Degree-Sign C which is significantly faster (on the order of tens of hours) and occurs at much lower temperatures ({approx}600 Degree-Sign C) compared to conventional reaction sintering. We found that the reaction significantly improves densification - the shrinkage rate of reaction-produced YAG was three times higher than that of YAG using pre-reacted powder. The Ce additions were found to retard the reaction driven shrinkage kinetics by a factor {approx}3, but are still faster (by a factor {approx}1.6) than those associated with direct densification (no synthesis). Densities >99% were achieved in both pure YAG and Ce doped YAG (Ce:YAG). Results of optical measurements show good transparency in the visible and

  11. Simultaneous synthesis and densification of transparent, photoluminescent polycrystalline YAG by current activated pressure assisted densification (CAPAD)

    International Nuclear Information System (INIS)

    Penilla, E.H.; Kodera, Y.; Garay, J.E.

    2012-01-01

    Highlights: ► We report a method for the synthesis of transparent and PL bulk polycrystalline Ce:YAG using CAPAD. ► The process uses γ-Al 2 O 3 , Y 2 O 3 , and CeO 2 nanopowders, reacted and densified simultaneously. ► The synthesis/densification kinetics are faster than those reported previously. ► Optical measurements show good transparency in the visible and photoluminescence (PL) in the Ce:YAG. ► The PL peak is broad and appears white when excited using blue light. - Abstract: We report a method for the synthesis and processing of transparent bulk polycrystalline yttrium aluminum garnet (YAG) and photoluminescent Ce-doped YAG ceramics via solid-state reactive-current activated pressure assisted densification (CAPAD). The process uses commercially available γ-Al 2 O 3 , Y 2 O 3 , and CeO 2 nanopowders. The nanopowders were reacted and densified simultaneously at temperatures between 850 °C and 1550 °C and at a maximum pressure of 105 MPa. The solid-state reaction to phase pure YAG occurs in under 4 min at processing temperatures 1100 °C which is significantly faster (on the order of tens of hours) and occurs at much lower temperatures (∼600 °C) compared to conventional reaction sintering. We found that the reaction significantly improves densification – the shrinkage rate of reaction-produced YAG was three times higher than that of YAG using pre-reacted powder. The Ce additions were found to retard the reaction driven shrinkage kinetics by a factor ∼3, but are still faster (by a factor ∼1.6) than those associated with direct densification (no synthesis). Densities >99% were achieved in both pure YAG and Ce doped YAG (Ce:YAG). Results of optical measurements show good transparency in the visible and photoluminescence (PL) in the Ce:YAG. The PL peak is broad and appears white when excited using blue light confirming that the ceramics can be used in solid state lighting to produce white light.

  12. Influence of Gamma-Ray Irradiation on Absorption and Fluorescent Spectra of Nd:YAG and Yb:YAG Laser Crystals

    Institute of Scientific and Technical Information of China (English)

    SUN Dun-Lu; ZHANG Qing-Li; XIAO Jing-Zhong; LUO Jian-Qiao; JIANG Hai-He; YIN Shao-Tang

    2008-01-01

    We investigate the influence of gamma-ray irradiation on the absorption and fluorescent spectra of Nd3+ : Y3Al5O12 (Nd:YAG) and Yb3+ :Y3Al5O12 (Yb:YAG) crystals grown by the Czochralski method. Two additional absorption (AA) bands induced by gamma-ray irradiation appear at 255nm and 340nm. The former is eontributed due to Fe3+ impurity, the latter is due to Fe2+ ions and F-type colour centres. The intensity of the excitation and emission spectra as well as the fluorescent lifetime of Nd:YAG crystal decrease after the irradiation of 100 Mrad gamma-ray. In contrast, the same dose irradiation does not impair the fluorescent properties of Yb: YA G crystal. These results indicate that Yb: YA G crystal possesses the advantage over Nd: YA G crystal that has better reliability for applications in harsh radiant environment.

  13. Q-switched pulse laser generation from double-cladding Nd:YAG ceramics waveguides.

    Science.gov (United States)

    Tan, Yang; Luan, Qingfang; Liu, Fengqin; Chen, Feng; Vázquez de Aldana, Javier Rodríguez

    2013-08-12

    This work reports on the Q-switched pulsed laser generation from double-cladding Nd:YAG ceramic waveguides. Double-cladding waveguides with different combination of diameters were inscribed into a sample of Nd:YAG ceramic. With an additional semiconductor saturable absorber, stable pulsed laser emission at the wavelength of 1064 nm was achieved with pulses of 21 ns temporal duration and ~14 μJ pulse energy at a repetition rate of 3.65 MHz.

  14. Combination of CO2 and Q-switched Nd:YAG lasers is more effective than Q-switched Nd:YAG laser alone for eyebrow tattoo removal.

    Science.gov (United States)

    Radmanesh, Mohammad; Rafiei, Zohreh

    2015-04-01

    The eyebrow tattoo removal using Q-switched lasers is usually prolonged. Other modalities may be required to enhance the efficacy and shorten the treatment course. To compare the efficacy of Q-switched neodymium-doped yttrium aluminum garnet (Nd:YAG) laser alone versus combination of Q-switched Nd:YAG and Ultrapulse CO2 lasers for eyebrow tattoo removal after a single session. After local anesthesia, the right eyebrow of 20 patients was treated with Ultrapulse CO2 laser with the parameters of 4 J/cm(2) and 3.2 J/cm(2) for the first and the second passes. Both eyebrows were then treated with 1064-nm and 532-nm Q-switched Nd:YAG laser. The spot size and pulse duration were 3 mm and 5 nanoseconds for both wavelengths, and the fluence was 7 J/cm(2) for 1064 nm and 3 J/cm (2) for 532 nm. The side treated with combination of Q-switched Nd:YAG and CO2 lasers improved 75-100% in 6 of 20 patients versus only 1 of 20 in the side treated with Q-switched Nd:YAG alone. Similarly, the right side in 13 of 20 patients showed more than 50% improvement with combination therapy versus the left side (the monotherapy side), where only 6 of 20 cases showed more than 50% improvement. The Mann-Whitney test was 2.85 for the right side and 1.95 for the left side (P value = 0.007). Using Ultra pulse CO2 laser enhances the efficacy of Q-switched Nd:YAG laser in eyebrow tattoo removal.

  15. Er:YAG Laser Dental Treatment of Patients Affected by Epidermolysis Bullosa

    Directory of Open Access Journals (Sweden)

    Angela Galeotti

    2014-01-01

    Full Text Available Aim. The purpose of this study was to evaluate the efficacy of Er:YAG laser used for treating hard dental tissue in patients with epidermolysis bullosa (EB. Methods. We report two cases of EB in which an Er:YAG laser was used for conservative treatments. In the first case, the Er:YAG laser (2,940 μm, 265 mJ, 25 Hz was used to treat caries on a deciduous maxillary canine in an 8-year-old male patient affected by dystrophic EB. In the second case, we treated a 26-year-old female patient, affected by junctional EB, with generalized enamel hypoplasia, and an Er:YAG laser (2,940 μm, 265 mJ, 25 Hz was used to remove the damaged enamel on maxillary incisors. Results. The use of the Er:YAG laser, with the appropriate energy, was effective in the selective removal of carious tissue and enamel hypoplasia. During dental treatment with the Er:YAG laser, patients required only a few interruptions due to the absence of pain, vibration, and noise. Conclusions. Laser treatment of hard dental tissues is a valuable choice for patients affected by EB since it is less invasive compared to conventional treatment, resulting in improved patient compliance.

  16. 10-kW-class YAG laser application for heavy components

    Science.gov (United States)

    Ishide, Takashi; Tsubota, S.; Nayama, Michisuke; Shimokusu, Yoshiaki; Nagashima, Tadashi; Okimura, K.

    2000-02-01

    The authors have put the YAG laser of the kW class to practical use for repair welding of nuclear power plant steam generator heat exchanger tubes, all-position welding of pipings, etc. This paper describes following developed methods and systems of high power YAG laser processing. First, we apply the 6 kW to 10 kW YAG lasers for welding and cutting in heavy components. The beam guide systems we have used are optical fibers which core diameter is 0.6 mm to 0.8 mm and its length is 200 m as standard one. Using these system, we can get the 1 pass penetration of 15 mm to 20 mm and multi pass welding for more thick plates. Cutting of 100 mm thickness plate data also described for dismantling of nuclear power plants. In these systems we carried out the in-process monitoring by using CCD camera image processing and monitoring fiber which placed coaxial to the YAG optical lens system. In- process monitoring by the monitoring fiber, we measured the light intensity from welding area. Further, we have developed new hybrid welding with the TIG electrode at the center of lens for high power. The hybrid welding with TIG-YAG system aims lightening of welding groove allowances and welding of high quality. Through these techniques we have applied 7 kW class YAG laser for welding in the components of nuclear power plants.

  17. Determination of the compressive yield strength for nano-grained YAG transparent ceramic by XRD analysis

    International Nuclear Information System (INIS)

    Wang, H.M.; Jiang, J.S.; Huang, Z.Y.; Chen, Y.; Liu, K.; Lu, Z.W.; Qi, J.Q.; Li, F.; He, D.W.; Lu, T.C.; Wang, Q.Y.

    2016-01-01

    Nano-grained ceramics have their unique mechanical characteristics that are not commonly found in their coarse-grained counterparts. In this study, nano-grained YAG transparent ceramics (NG-YAG) were prepared by low-temperature high-pressure technique (LTHP). The peak profile analysis of the X-ray diffraction was employed to investigate the compressive yield strength of NG-YAG. During the temperature at 450 °C, the residual micro-strain (RMS) increased with increasing loading pressure. However when the loading pressure was exceeded to 4.0 GPa the RMS exhibited a severe negative slop. The temperature effects on the compressive yield strength were also studied. It shows that the compressive yield strength of NG-YAG is 4.0 GPa and 5.0 GPa respectively at 450 °C and 350 °C. More importantly according to this investigation, a feasible technique to study the nano-grained ceramics is provided. - Graphical abstract: Fig. 2 shows the significant slope changes of calculated residual micro-strain (RMS) associated with five selected pressure-temperature conditions. Another the grain size estimated from Scherrer's formula, especially when it changes with the pressure-temperature condition is also plotted in Fig. 2. - Highlights: • Prepared the nano-grained YAG transparent ceramic by high pressure technique. • Obtained the compressive yield with different temperature. • Obtained the compressive yield of nano-grained YAG transparent ceramic.

  18. Co-precipitation synthesis of YAG:Dy nanophosphor and its thermometric properties

    International Nuclear Information System (INIS)

    Chong, Joo-Yun; Zhang, Yuelan; Wagner, Brent K.; Kang, Zhitao

    2013-01-01

    Highlights: •YAG:Dy nanophosphors were synthesized with particle size of about 50 nm. •Optimized doping concentration of 6%Dy was determined. •Thermometric photoluminescence properties were studied between 20 and 350 °C. •Temperature-sensitive change in peak ratio of 496/457 nm emissions was demonstrated. •Suitable for potential thermographic applications when dispersed in a liquid media. -- Abstract: Dy 3+ doped yttrium aluminum garnet (YAG) nanophosphors were synthesized by a co-precipitation method for potential thermographic applications in a liquid media dispersed with fluorescent nanoparticles. The doping concentration and annealing temperature on the structural and optical properties of YAG:Dy were investigated. Pure phase YAG:Dy nanophosphors were obtained by annealing the co-precipitated hydroxide products at above 900 °C. Maximum photoluminescence intensity was observed from 6%Dy doped YAG samples. The effect of measuring temperature between 20 and 350 °C on the photoluminescence spectra of nano YAG:Dy was investigated. A temperature-sensitive change in the peak intensity ratio of 496/457 nm emission lines was demonstrated for such nanophosphors for the first time, suggesting potential applications in temperature monitoring of fuel spray

  19. Co-precipitation synthesis of YAG:Dy nanophosphor and its thermometric properties

    Energy Technology Data Exchange (ETDEWEB)

    Chong, Joo-Yun [School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Zhang, Yuelan [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Wagner, Brent K. [Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Kang, Zhitao, E-mail: zhitao.kang@gtri.gatech.edu [Georgia Tech Research Institute, Georgia Institute of Technology, Atlanta, GA 30332 (United States); School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2013-12-25

    Highlights: •YAG:Dy nanophosphors were synthesized with particle size of about 50 nm. •Optimized doping concentration of 6%Dy was determined. •Thermometric photoluminescence properties were studied between 20 and 350 °C. •Temperature-sensitive change in peak ratio of 496/457 nm emissions was demonstrated. •Suitable for potential thermographic applications when dispersed in a liquid media. -- Abstract: Dy{sup 3+} doped yttrium aluminum garnet (YAG) nanophosphors were synthesized by a co-precipitation method for potential thermographic applications in a liquid media dispersed with fluorescent nanoparticles. The doping concentration and annealing temperature on the structural and optical properties of YAG:Dy were investigated. Pure phase YAG:Dy nanophosphors were obtained by annealing the co-precipitated hydroxide products at above 900 °C. Maximum photoluminescence intensity was observed from 6%Dy doped YAG samples. The effect of measuring temperature between 20 and 350 °C on the photoluminescence spectra of nano YAG:Dy was investigated. A temperature-sensitive change in the peak intensity ratio of 496/457 nm emission lines was demonstrated for such nanophosphors for the first time, suggesting potential applications in temperature monitoring of fuel spray.

  20. A rapid tattoo removal technique using a combination of pulsed Er:YAG and Q-Switched Nd:YAG in a split lesion protocol.

    Science.gov (United States)

    Sardana, Kabir; Ranjan, Rashmi; Kochhar, Atul M; Mahajan, Khushbu Goel; Garg, Vijay K

    2015-01-01

    Tattoo removal has evolved over the years and though Q-switched laser is the 'workhorse' laser, it invariably requires multiple sittings, which are dependent on numerous factors, including the skin colour, location of the tattoo, age of the tattoo, colour of pigment used, associated fibrosis and the kind of tattoo treated. Though ablative lasers, both pulsed CO2 and Er:YAG, have been used for recalcitrant tattoos, very few studies have been done comparing them with pigment-specific lasers. Our study was based on the premise that ablating the epidermis overlying the tattoo pigment with Er:YAG could help in gaining better access to the pigment which would enable the Q-switched laser to work effectively with less beam scattering. A study of rapid tattoo removal (RTR) technique using a combination of pulsed Er:YAG and Q-Switched Nd:YAG in a split lesion protocol. This prospective study was undertaken during 2010-13 at a laser Clinic in the Maulana Azad Medical College, New Delhi. A total of 10 patients were recruited, 5 of amateur tattoo and 5 of professional tattoo. After informed consent each tattoo was arbitrarily 'split' into two parts. One part was treated with QS Nd:YAG laser(1064 nm) and the other part with Er:YAG laser immediately followed by the QS Nd:YAG. The laser treatments were repeated at 6-week intervals until the tattoo pigment had cleared. On the combination side in subsequent sittings only the QS Nd:YAG was used, to minimize repetitive ablation. To ensure consistency in the intervention methods a trained dermatologist who was independent of the treatment delivery randomly rated 10% of the procedures. The mean improvement achieved by the Q-switched laser (2.93) was less than the combination laser (3.85) side (p = 0.001) and needed more sessions (3.8 vs. 1.6; p = 0.001). There was a statistically significant difference in the improvement on the combination side till the second session. On the combination side patients required a maximum of 2 sessions

  1. Marginal microleakage in vitro study on class V cavities prepared with Er:YAG laser and etched with acid or etched with Er:YAG laser and acid

    International Nuclear Information System (INIS)

    Tavares, Henrique Dutra Simoes

    2001-01-01

    Microleakage at the interface between the teeth and the restorative materials remains a problem with composite resin restorations. Microleakage at the gingival margins of class V cavities restorations still challenge as they are usually placed in dentin and/or cementum. Previous studies have shown that the cavity preparation with Er:YAG laser is possible. It has been reported that Er:YAG laser has ability to create irregular surface providing micromechanical retention for adhesive dental restorative materials and to improve marginal sealing. The purpose of this in vitro study was to evaluate the marginal microleakage on class V cavities prepared with Er:YAG laser and etched with acid or with Er:YAG laser and acid, in compared to those prepared and etched conventionally. Thirty human molars were divided into three groups, namely: group I - prepared with Er:YAG laser (KaVo KEY Laser II - Germany) and etched with 37% phosphoric acid; group II - prepared with Er:YAG laser and etched with Er:YAG laser and 37% phosphoric acid; group III (control group) - prepared with high speed drill and etched with 37% phosphoric acid. All cavities were treated with same adhesive system (Single Bond - 3M) and restored with the composite resin (Z100 - 3M), according to the manufacturer's instructions. The specimens were stored at 37 deg C in water for 24 hours, polished with Sof-Lex discs (3M), thermally stressed, sealed with a nail polish coating except for the area of the restoration and 1 mm around it, and immersed in a 50% aqueous solution of silver nitrate for 24 hours. After that, the specimens were rinsed in water, soaked in a photodeveloping solution and exposed to a fluorescent light for 8 hours. The teeth were embedded in an autopolymerizing resin and sectioned longitudinally using a diamond saw microtome under running water. The sections were photographed. The microleakage at the occlusal cavity and at the gingival margins of each specimen was evaluated with scores (0-3) by

  2. Observations of OH and HO2 radicals in coastal Antarctica

    Directory of Open Access Journals (Sweden)

    S. J.-B. Bauguitte

    2007-08-01

    Full Text Available OH and HO2 radical concentrations have been measured in the boundary layer of coastal Antarctica for a six-week period during the austral summer of 2005. The measurements were performed at the British Antarctic Survey's Halley Research Station (75° 35' S, 26° 19' W, using the technique of on-resonance laser-induced fluorescence to detect OH, with HO2 measured following chemical conversion through addition of NO. The mean radical levels were 3.9×105 molecule cm−3 for OH, and 0.76 ppt for HO2 (ppt denotes parts per trillion, by volume. Typical maximum (local noontime levels were 7.9×105 molecule cm−3 and 1.50 ppt for OH and HO2 respectively. The main sources of HOx were photolysis of O3 and HCHO, with potentially important but uncertain contributions from HONO and higher aldehydes. Of the measured OH sinks, reaction with CO and CH4 dominated, however comparison of the observed OH concentrations with those calculated via the steady state approximation indicated that additional co-reactants were likely to have been present. Elevated levels of NOx resulting from snowpack photochemistry contributed to HOx cycling and enhanced levels of OH, however the halogen oxides IO and BrO dominated the CH3O2 – HO2 – OH conversion in this environment, with associated ozone destruction.

  3. Production of dispersed nanometer sized YAG powders from alkoxide, nitrate and chloride precursors and spark plasma sintering to transparency

    International Nuclear Information System (INIS)

    Suarez, M.; Fernandez, A.; Menendez, J.L.; Torrecillas, R.

    2010-01-01

    Yttrium aluminum garnet (YAG) was synthesized from different starting materials, i.e., alkoxide, nitrate and chloride precursors. The conversion steps from the precursors to crystalline YAG were studied by Raman spectroscopy. Dispersed YAG powders were formed at a relatively low temperature, around 800 o C by the chlorides route, whereas alkoxide precursors needed firing over 900 o C and nitrates even over 1100 o C. Lyophilized YAG gel was sintered to transparency by the spark plasma sintering method at 1500 o C with in-line transmittances close to 60% at 680 nm and over 80% in the infrared range.

  4. In vitro studies of morphological changes in enamel surface after Er:YAG and Nd:YAG laser irradiation, by SEM

    International Nuclear Information System (INIS)

    Verlangieri, Eleonora Jaeger

    2001-01-01

    The caries prevention by using laser irradiation has been investigated by many authors using various lasers with different irradiations conditions. The purpose of this study was to investigated the morphological changes in enamel surface after Er:YAG and Nd:YAG laser irradiation, in vitro, by SEM. Fifteen freshly extracted, intact, caries-free, human third molars, were used in this study. The coronary portions were sectioned, from buccal to lingual direction, in two half-parts. Each one was irradiated by a different laser. The first one was irradiated with water-air spray, by a Nd:YAG laser, at 1.084 nm wave length, at 10 W, 10 Hz, 100 mJ for 60 sec., with an optical fiber in contact mode (0,32 mm of diameter); and the other half, with water-air spray by an Er:YAG laser at 2,94 micrometers wave length at the parameters of 4 Hz, 80 mJ, 24.95 J/cm 2 for 60 sec. The results of this study suggested that both lasers promoted morphological changes in the enamel surface enhancing resistance and can be an alternative clinical method for caries preventions. (author)

  5. [Is prophylactic YAG iridotomy useful in pigment dispersion syndrome?].

    Science.gov (United States)

    Rosentreter, A; Schwenn, O; Funk, J; Dietlein, T

    2013-04-01

    Despite theoretical considerations concerning the advantage of iridotomy in eyes with pigment dispersion syndrome or early pigment glaucoma, there is a lack of clinical evidence that this procedure has a long-term effect in preventing glaucoma damage under these circumstances. However, several factors may contribute to this lack of evidence, e.g. the statistical problem of a low conversion rate from pigment dispersion syndrome to pigment glaucoma or the inclusion criteria in the studies treating patients older than 40 years or genetic dispositions in pigment glaucoma that are not yet fully clear. On the basis of current data the decision for YAG iridotomy should only be taken in patients younger than 40 years, if the midperipheral iris shows an inverse bowing and the intraocular pressure is normal or slightly increased with no progressive signs of optic nerve damage. In cases of insufficient intraocular pressure and visual defects due to glaucomatous optic nerve damage, incisional glaucoma surgery is usually necessary especially in younger patients with a long life expectancy.

  6. Integrated chemical process for exothermic wave synthesis of high luminance YAG:Ce phosphors

    International Nuclear Information System (INIS)

    Won, C.W.; Nersisyan, H.H.; Won, H.I.; Youn, J.W.

    2011-01-01

    In this paper, high-luminance yellow-emitting Y 3 Al 5 O 12 :Ce 3+ phosphor (YAG:Ce) microparticles were prepared in a solid flame using a 1.425Y 2 O 3 +2.5Al 2 O 3 +0.15CeO 2 +k(KClO 3 +urea)+mNH 4 F precursor mixture (here k is the number of moles of the KClO 3 +urea red-ox mixture, and m is the number of moles of NH 4 F). The self-sustaining combustion process for the entire reaction sample was provided by the heat generated from the KClO 3 +urea mixture. Parametric studies demonstrated that the maximum temperature in the combustion wave varied from 885 to 1200 deg. C for k=2.0-3.0 mole and m=0-1.5 mole. X-ray analysis results showed that the product obtained in the solid flame consisted of Y 3 Al 5 O 12 :Ce 3+ and KCl phases. Therefore, after dissolving potassium chloride in distillated water, pure-phase YAG:Ce phosphor powder was obtained. The as-prepared YAG:Ce phosphor particles had diameters of 10-25 μm and good dispersity and exhibited luminescence properties comparable to those of YAG:Ce phosphor powders prepared by conventional high-temperature processing. - Highlights: → A new solid-flame strategy was developed for synthesizing high-luminance YAG:Ce phosphor. → Adding KClO 3 +CO(NH 2 ) 2 +NH 4 F mixture to oxide powders provides a low-temperature combustion process. → YAG:Ce phosphor particles 10-25 μm in diameter were obtained at 1000-1100 deg. C within tens of seconds. → As-prepared YAG:Ce emission intensity was 90.1-103.2% compared to that of the reference sample.

  7. Embedding of $^{163}$Ho and $^{166m}$ Ho in the energy absorbers of low temperature metallic magnetic calorimeters

    CERN Multimedia

    The calorimetric measurement of the $^{163}$Ho electron capture spectrum is a promising tool to investigate the electron neutrino mass. A suitable method to embed the source in the detectors is the ion-implantation. This process has already been used to embed $^{163}$Ho ions in micro-fabricated low temperature metallic magnetic prototypes. The $^{163}$Ho electron capture spectrum obtained with these first prototypes is presently the most precise with an energy resolution of $\\Delta$$\\textit{E}$$_{FWHM}$ = 7.6 eV. In order to test the performance of the new generation of low temperature metallic magnetic calorimeters, we propose to perform a $^{163}$Ho ion-implantation on the new chip having two arrays consisting of 32 pixels each. An activity of about 1 Bq per pixel is required. With this new detector array we will be able to achieve a better energy resolution and to acquire a higher statistics which allows for studying the $^{163}$Ho spectral shape. We propose also to perform an ion-implantation of $^{166m}$...

  8. Konstrukce vřeten vícevřetenového soustružnického automatu

    OpenAIRE

    Kráčmar, Tomáš

    2016-01-01

    Obsahem diplomové práce je konstrukce vřeten vícevřetenového soustružnického automatu pro práci z tyče maximálního průměru 7 mm. Práce se zabývá novou koncepcí pohonu vřeten, kde jsou vřetena poháněna externími asynchronními motory přes ozubená kola s vnitřním ozubením uložená vně vřetenového bubnu namísto současného způsobu pohonu centrálními koaxiálními hřídeli. Součástí práce je rešerše vícevřetenových automatů včetně popisu hlavních uzlů, konstrukční návrh, pevnostní výpočty, výpočty trva...

  9. Návrh internetového obchodu pro firmu

    OpenAIRE

    Fikáčková, Barbora

    2007-01-01

    Bakalářské práce analyzuje problémy související s tvorbou internetového obchodu. Obsahuje návrh vhodného řešení pro zlepšení budoucího postavení firmy AMAR marketing s.r.o. a jeho ekonomické zhodnocení. Bachelor work analyzes problems in connection with creation of internet shop. for the firm AMAR marketing s.r.o. It contains analysis of suitable solution, leading to improve future position of the firm AMAR marketing s.r.o. and its econo-mic evulation. A

  10. Proton Radioactivity Measurements at HRIBF: Ho, Lu, and Tm Isotopes

    International Nuclear Information System (INIS)

    Akovali, Y.; Batchelder, J.C.; Bingham, C.R.; Davinson, T.; Ginter, T.N.; Gross, C.J.; Grzywacz, R.; Hamilton, J.H.; Janas, Z.; Karny, M.; Kim, S.H.; MacDonald, B.D.; Mas, J.F.; McConnell, J.W.; Piechaczek, A.; Ressler, J.J.; Rykaczewski, K.; Slinger, R.C.; Szerypo, J.; Toth, K.S.; Weintraub, W.; Woods, P.J.; Yu, C.-H.; Zganjar, E.F.

    1998-01-01

    Two new isotopes, 145 Tm and 140 Ho and three isomers in previously known isotopes, 141m Ho, 150m Lu and 151m Lu have been discovered and studied via their decay by proton emission. These proton emitters were produced at the Holifield Radioactive Ion Beam Facility (HRIBF) by heavy-ion fusion-evaporation reactions, separated in A/Q with a recoil mass spectrometer (RMS), and detected in a double-sided silicon strip detector (DSSD). The decay energy and half-life was measured for each new emitter. An analysis in terms of a spherical shell model is applied to the Tm and Lu nuclei, but Ho is considerably deformed and requires a collective model interpretation

  11. Evaluation of the permeability and morphological alteration of the dental surface after apicoectomy, treatment and preparation with Er:YAG and Nd:YAG lasers

    International Nuclear Information System (INIS)

    Oliveira, Rodrigo Guerra de

    2001-01-01

    One of the objectives of endodontic treatment is to resolve pathological periapical processes caused by microbial contamination of the dental pulp. Correct execution of the necessary chemical preparation prior to surgery generally results in positive outcomes. However, a percentage of cases do not respond favorably and therefore require retreatment, a conservative therapeutic option. There are meanwhile a number of treatment failures which do not respond to these conservative measures and must therefore be subjected to paraendodontic surgical procedures. One of the principal problems of this therapeutic conduct is linked to the surface permeability of the dentin after apicoectomy and the lack of adequate marginal adaptation between the retrofilling material and the cavity walls. This permits the percolation of microorganisms and their metabolic by products from the system of root canals to the periapical region, thereby compromising the necessary tissue repair. The present work proposes the evaluation of the surface and marginal permeability of cut dentin after apicoectomy and treatment with Er:YAG and Nd:YAG lasers with fiber optics and then retrofilled with intermediate restorative material (IRM). A total of 24 single rooted teeth whose canals were endodontically treated were divided into 3 experimental groups: group I, whose apices were sectioned with an Er:YAG laser and the resulting cavity and the cut dental surface were irradiated with this laser via a 50/10 type fiber; in group II the apicoectomy was conducted with an Er:YAG laser and the resulting cavity and the cut surface were irradiated with a Nd:YAG laser; in group III, the samples were apicoectomized and the cavities were treated with a high speed bur (control group). Analysis of the infiltration of the dye methylene blue throughout the cut dental surface and the reconstruction demonstrated that the samples in the irradiated groups presented lower indices of infiltration than the control group. The

  12. Lattice effects in HoVo3 single crystal

    International Nuclear Information System (INIS)

    Sikora, M.; Marquina, C.; Ibarra, M.R.; Nugroho, A.A.; Palstra, T.T.M.

    2007-01-01

    We report the study of lattice effects in the Mott insulator HoVO 3 performed by means of linear thermal expansion on a single crystal in the temperature range 10-290 K. The holmium orthovanadate HoVO 3 reveals gradual orbital ordering (OO) below T OO =200 K and orders antiferromagnetically at T N =113 K. A first-order structural phase transition takes place at T S ∼38 K, which is probably accompanied by change of the OO type and hence the type of antiferromagnetic spin ordering

  13. The uptake of HO2 radicals to organic aerosols

    Science.gov (United States)

    Matthews, Pascale; Krapf, Manuel; Dommen, Josef; George, Ingrid; Whalley, Lisa; Ingham, Trevor; Baeza-Romero, Maria Teresa; Ammann, Markus; Heard, Dwayne

    2014-05-01

    HOx (OH + HO2) radicals are responsible for the majority of the oxidation in the troposphere and control the concentrations of many trace species in the atmosphere. There have been many field studies where the measured HO2 concentrations have been smaller than the concentration predicted by model calculations [1,2]. The difference has often been attributed to HO2 uptake by aerosols. Organics are a major component of aerosols accounting for 10 - 70 % of their mass [3]. However, there have been very few laboratory studies measuring HO2 uptake onto organic aerosols [4]. Uptake coefficients (γ) were measured for a range of aerosols using a Fluorescence Assay By Gas Expansion (FAGE) detector combined with an aerosol flow tube. HO2 was injected into the flow tube using a moveable injector which allowed first order HO2 decays to be measured along the flow tube both with and without aerosols. Laboratory generated aerosols were made using an atomiser or by homogeneous nucleation. Secondary organic aerosols (SOA) were made using the Paul Scherrer Institute smog chamber and also by means of a Potential Aerosol Mass (PAM) chamber. The total aerosol surface area was then measured using a Scanning Mobility Particle Sizer (SMPS). Experiments were carried out on aerosols containing glutaric acid, glyoxal, malonic acid, stearic acid, oleic acid and squalene. The HO2 uptake coefficients for these species were measured in the range of γ contained elevated levels of transition metal ions. For humic acid the uptake coefficient was highly dependent on humidity and this may be explained by the liquid water content of the aerosols. Measurements were also performed on copper doped aerosols containing different organics. An uptake coefficient of 0.23 ± 0.07 was measured for copper doped ammonium sulphate, however, this was reduced to 0.008 ± 0.009 when EDTA was added in a 1:1 ratio with copper and 0.003 ± 0.004 when oxalic acid was added in a 10:1 ratio with copper. SOA aerosols were

  14. 166Ho-chitosan as a radiation synovectomy agent - biocompatibility study of 166Ho-chitosan in rabbits

    International Nuclear Information System (INIS)

    Kim, Sug Jun; Lee, Soo Yong; Jeon, Dae Geun; Lee Jong Seok

    1997-01-01

    Radiation synovectomy is a noninvasive therapy that has been investigated as an alternative to surgical synovectomy. It is been successfully employed in the treatment of synovitis in rheumatoid arthrits and other inflammatory arthropathies. We developed the 166 Ho-chitosan complex for possible use as a radiation synovectomy agent. Holmium is the more practical isotope based on its higher radioactivity and logner half-life. And isotope based on its higher radioactivity and logner half-life. And chitosan is ideal and suitable particles based on its soluble and biodegradable characteristics. So we investigated the biocompatibility of the 166 Ho-chitosan complex to evaluated the suitability as a radiation synovectomy agent. In this study, we performed in vivo and in vitro stability test and biodistribution test. Our results indicate that 166 Ho-chitosan may be an effective radiopharmaceutical for radiation synovectomy. (author). 30 refs., 7 tabs

  15. {sup 166}Ho-chitosan as a radiation synovectomy agent - biocompatibility study of {sup 166}Ho-chitosan in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sug Jun; Lee, Soo Yong; Jeon, Dae Geun; Seok, Lee Jong [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1997-01-01

    Radiation synovectomy is a noninvasive therapy that has been investigated as an alternative to surgical synovectomy. It is been successfully employed in the treatment of synovitis in rheumatoid arthrits and other inflammatory arthropathies. We developed the {sup 166}Ho-chitosan complex for possible use as a radiation synovectomy agent. Holmium is the more practical isotope based on its higher radioactivity and logner half-life. And isotope based on its higher radioactivity and logner half-life. And chitosan is ideal and suitable particles based on its soluble and biodegradable characteristics. So we investigated the biocompatibility of the {sup 166}Ho-chitosan complex to evaluated the suitability as a radiation synovectomy agent. In this study, we performed in vivo and in vitro stability test and biodistribution test. Our results indicate that {sup 166}Ho-chitosan may be an effective radiopharmaceutical for radiation synovectomy. (author). 30 refs., 7 tabs.

  16. Electronic transitions of Ho in Pb2Sr2HoCu3O8 observed by inelastic neutron scattering

    International Nuclear Information System (INIS)

    Soderholm, L.; Loong, C.; Xue, J.S.; Hammonds, J.P.; Greedan, J.E.; Maric, M.

    1993-01-01

    The electronic behavior of the 5 I 8 Russell Saunders ground multiplet of Ho 3+ in Pb 2 Sr 2 HoCu 3 O 8 has been investigated using inelastic neutron scattering. We observe ten peaks in the excitation spectra that are associated with crystal field transitions. The peaks are only slightly broader than expected from instrument resolution, indicating that there are no strong interactions between the local Ho f states and the CuO conduction states. Comparing the energies and intensities of the experimental peaks with those expected from modeling convinces us that there are at least three states populated at the temperature of our experiment (15 K), making the assignments of transitions very difficult in the absence of further data

  17. Nd:YAG laser therapy for rectal and vaginal venous malformations.

    Science.gov (United States)

    Gurien, Lori A; Jackson, Richard J; Kiser, Michelle M; Richter, Gresham T

    2017-08-01

    Limited therapeutic options exist for rectal and vaginal venous malformations (VM). We describe our center's experience using Nd:YAG laser for targeted ablation of abnormal veins to treat mucosally involved pelvic VM. Records of patients undergoing non-contact Nd:YAG laser therapy of pelvic VM at a tertiary children's hospital were reviewed. Symptoms, operative findings and details, complications, and outcomes were evaluated. Nine patients (age 0-24) underwent Nd:YAG laser therapy of rectal and/or vaginal VM. Rectal bleeding was present in all patients and vaginal bleeding in all females (n = 5). 5/7 patients had extensive pelvic involvement on MRI. Typical settings were 30 (rectum) and 20-25 W (vagina), with 0.5-1.0 s pulse duration. Patients underwent the same-day discharge. Treatment intervals ranged from 14 to 180 (average = 56) weeks, with 6.1-year mean follow-up. Five patients experienced symptom relief with a single treatment. Serial treatments managed recurrent bleeding successfully in all patients, with complete resolution of vaginal lesions in 40% of cases. No complications occurred. Nd:YAG laser treatment of rectal and vaginal VM results in substantial improvement and symptom control, with low complication risk. Given the high morbidity of surgical resection, Nd:YAG laser treatment of pelvic VM should be considered as first line therapy.

  18. Er:YAG Laser and Fractured Incisor Restorations: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    C. Fornaini

    2012-01-01

    Full Text Available Introduction. The aim of this study was to analyse the effects of an Er:YAG laser on enamel and dentine in cases of dental restorations involving fractured teeth, utilizing the dental fragment. Materials and Methods. Seventy-two freshly extracted bovine incisors were fractured at the coronal level by using a hammer applied with a standardized method, and the fragment was reattached by using three different methods: Er:YAG laser, orthophosphoric acid, and laser plus acid. The different groups were evaluated by a test realized with the dynamometer to know the force required to successfully detach the reattached fragment and by a microinfiltration test by using a 0.5% methylene blue solution followed by the optic microscope observation. Results. The compression test showed only a slight difference between the three groups, without any statistical significance. The infiltration test used to evaluate the marginal seal between the fracture fragment and the tooth demonstrated that etching with Er:YAG laser alone or in combination with orthophosphoric acid gives better results than orthophosphoric acid alone, with a highly significant statistical result. Discussion. Reattaching a tooth fragment represents a clinically proven methodology, in terms of achieving resistance to detachment, and the aim of this work was to demonstrate the advantages of Er:YAG laser on this procedure. Conclusion. This “in vitro” study confirms that Er:YAG laser can be employed in dental traumatology to restore frontal teeth after coronal fracture.

  19. Er:YAG delamination of immersed biological membranes using sealed flexible hollow waveguides

    Science.gov (United States)

    Sagi-Dolev, A. M.; Dror, Jacob; Inberg, Alexandra; Ferencz, J. R.; Croitoru, Nathan I.

    1996-04-01

    The radiation of Er-YAG laser ((lambda) equals 2.94 micrometer) gives selective interaction with tissues. The extinction in soft tissues is only a few micrometers and in hard tissues is of the order of hundreds of micrometers. This makes this type of laser very suitable for treatments in dentistry, orthopedy, or ophthalmology. Because the usual silica fibers are not transmitting the radiation at lambda equals 2.94 micrometer of this laser, many applications cannot be presently performed. Fused silica hollow fibers for Er-YAG radiation were developed in our laboratory and several possible applications in dentistry, orthopedy and ophthalmology were indicated. Hole opening and implantation preparation of teeth were experimented, using Er-YAG laser and hollow plastic waveguide delivery systems. Hole drilling in cow bones was demonstrated for applications in orthopedy. A new procedure of delivering Er-YAG radiation on fibrotic membranes of inner eggshell as a model of the membranes in eyes was developed employing silica hollow waveguides of 0.5 and 0.7 mm ID or a plastic waveguide of 1.0 mm ID. For this purpose waveguides with sealed distal tip were employed to enable us to approach the delivery system through liquid media near to the membrane. This experiment demonstrates the possibility of surgical applications in vitectomy in ophthalmology using Er-YAG laser and silica hollow waveguides.

  20. Management of intermittent angle closure glaucoma with Nd: yag laser iridotomy as a primary procedure

    International Nuclear Information System (INIS)

    Ahmed, M.

    2006-01-01

    To assess the efficacy and complications of Nd: YAG laser iridotomy in patients with intermittent (sub-acute) angle closure glaucoma. Twenty-five eyes of twenty-three patients with periodic (intermittent) angle closure, selected in outpatient department, were kept on pilocarpine until YAG laser iridotomy was performed. After YAG laser iridotomy oral acetazolamide and topical dexamethasone was used to control post laser rise of IOP and inflammation respectively. Patency of iridotomy was confirmed and intra-ocular pressure was measured one hour after the procedure. Immediate complication, if any, was noted. Follow-up was done for six months. Prophylactic laser iridotomy was done in fellow eye with occludable angle. Levene's test for equality of variance and t-test for equality of means were used for statistical analysis. This study revealed a significant difference in IOP before and after YAG laser iridotomy (p = .002). Complete follow-up of 6 months was possible in 25 eyes of 23 subjects. After YAG Laser iridotomy, 21 (84%) eyes showed negative provocative test, intraocular pressure below 19mm Hg without medication and anterior chamber angle no more occludable and were labeled successful. Iridotomy remained patent in 96% of eyes. Iridotomy failed to reduce IOP in 4 (16%) eyes. The complications were minimal and transient. (author)

  1. Optical transitions of Ho(3+) in oxyfluoride glasses and upconversion luminescence of Ho(3+)/Yb(3+)-codoped oxyfluoride glasses.

    Science.gov (United States)

    Feng, Li; Wu, Yinsu

    2015-05-05

    Optical properties of Ho(3+)-doped SiO2-BaF2-ZnF2 glasses have been investigated on the basis of the Judd-Ofelt theory. Judd-Ofelt intensity parameters, radiative transition probabilities, fluorescence branching ratios and radiative lifetimes have been calculated for different glass compositions. Upconversion emissions were observed in Ho(3+)/Yb(3+)-codoped SiO2-BaF2-ZnF2 glasses under 980nm excitation. The effects of composition, concentration of the doping ions, and excitation pump power on the upconversion emissions were also systematically studied. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Plasma plume expansion dynamics in nanosecond Nd:YAG laserosteotome

    Science.gov (United States)

    Abbasi, Hamed; Rauter, Georg; Guzman, Raphael; Cattin, Philippe C.; Zam, Azhar

    2018-02-01

    In minimal invasive laser osteotomy precise information about the ablation process can be obtained with LIBS in order to avoid carbonization, or cutting of wrong types of tissue. Therefore, the collecting fiber for LIBS needs to be optimally placed in narrow cavities in the endoscope. To determine this optimal placement, the plasma plume expansion dynamics in ablation of bone tissue by the second harmonic of a nanosecond Nd:YAG laser at 532 nm has been studied. The laserinduced plasma plume was monitored in different time delays, from one nanosecond up to one hundred microseconds. Measurements were performed using high-speed gated illumination imaging. The expansion features were studied using illumination of the overall visible emission by using a gated intensified charged coupled device (ICCD). The camera was capable of having a minimum gate width (Optical FWHM) of 3 ns and the timing resolution (minimum temporal shift of the gate) of 10 ps. The imaging data were used to generate position-time data of the luminous plasma-front. Moreover, the velocity of the plasma plume expansion was studied based on the time-resolved intensity data. By knowing the plasma plume profile over time, the optimum position (axial distance from the laser spot) of the collecting fiber and optimal time delay (to have the best signal to noise ratio) in spatial-resolved and time-resolved laser-induced breakdown spectroscopy (LIBS) can be determined. Additionally, the function of plasma plume expansion could be used to study the shock wave of the plasma plume.

  3. Site preference and elastic properties of ternary alloying additions in B2 YAg alloys by first-principles calculations

    Energy Technology Data Exchange (ETDEWEB)

    Wu Yurong, E-mail: winwyr@126.com [College of Electromechanical Engineering, Hunan University of Science and Technology, Xiantang 411201 (China); Hu Wangyu [Department of Applied Physics, Hunan University, Changsha 410082 (China); Xu Longshan [Department of Materials Science and Engineering, Xiamen University of Technology, Xiamen 361024 (China)

    2012-09-15

    First-principles calculations were preformed to study the site preference behavior and elastic properties of 3d (Ti-Cu) transition-metal elements in B2 ductility YAg alloy. In YAg, Ti is found to occupy the Y sublattice whereas V, Cr, Co, Fe, Ni and Cu tend to substitute for Ag sublattice. Due to the addition of 3d transition metals, the lattice parameters of YAg is decreased in the order: VYAg alloy, and Fe is the most effective element to improve the ductility of YAg, while Ti, Ni and V alloying elements can reduce the ductility of YAg alloy, especially, V transforms ductile into brittle for YAg alloy. In addition, both V and Ni alloying elements can increase the hardness of YAg alloy, and Y{sub 8}Ag{sub 7}V is harder than Y{sub 8}Ag{sub 7}Ni.

  4. SEM evaluation of the morphological changes in hard dental tissues prepared by Er: YAG laser and rotary instruments

    Directory of Open Access Journals (Sweden)

    Tomov Georgi

    2010-09-01

    Full Text Available Effective ablation of dental hard tissues by means of the erbium:yttrium-aluminum garnet (Er: YAG laser has been reported recently, and its application to caries removal and cavity preparation has been expected. However, few studies have investigated the morphological changes in hard dental tissues after Er: YAG laser caries treatment. In the present study the morphological changes in hard dental tissues after Er: YAG laser caries ablation in vitro was compared with that of conventional mechanical treatment. Thirty extracted human teeth with caries were used. Ten tooth was treated with the Er: YAG laser, and the other was treated with a conventional steel and diamond burs. Laser treatment was performed by means of a non-contact irradiation modes with cooling water spray, with a new Er: YAG laser (LiteTouch. Conventional bur treatment was conducted by means of a low-speed micromotor and air turbine with water cooling. Scanning electron microscope (SEM observations were performed for each treatment. The Er: YAG laser ablated carious dentin effectively with minimal thermal damage to the surrounding intact dentin, and removed infected and softened carious dentin to the same degree as the burtreatment. In addition, a lower degree of vibration was noted with the Er: YAG laser treatment. The SEM examination revealed characteristic micro-irregularities of the lased dentin and enamel surfaces with potential benefits for adhesive restorations. Our results show that the Er: YAG laser is promising as a new technical modality for caries treatment

  5. Laser amplification of optical images using a CW Nd:YAG amplifier

    International Nuclear Information System (INIS)

    Aman, H

    2013-01-01

    In this paper a scheme for the amplification of optical images is described, using a continuous wave (CW) diode-pumped Nd:YAG (yttrium aluminum garnet) laser module. A passively q-switched end-pumped Nd:YAG laser is used as a pump source, which carries the optical image distribution as an input which is transmitted towards the amplifier at a distance of about ten feet. For amplification, a three-side-pumped CW Nd:YAG laser module is utilized without the cavity mirrors. In this way, optical images are amplified by a factor of 3.2 and imaged at a distance of ten feet with a spatial resolution of 500 μm. (paper)

  6. Laser-diode pumped 40-W Yb:YAG ceramic laser.

    Science.gov (United States)

    Hao, Qiang; Li, Wenxue; Pan, Haifeng; Zhang, Xiaoyi; Jiang, Benxue; Pan, Yubai; Zeng, Heping

    2009-09-28

    We demonstrated a high-power continuous-wave (CW) polycrystalline Yb:YAG ceramic laser pumped by fiber-pigtailed laser diode at 968 nm with 400 mum fiber core. The Yb:YAG ceramic laser performance was compared for different Yb(3+) ion concentrations in the ceramics by using a conventional end-pump laser cavity consisting of two flat mirrors with output couplers of different transmissions. A CW laser output of 40 W average power with M(2) factor of 5.8 was obtained with 5 mol% Yb concentration under 120 W incident pump power. This is to the best of our knowledge the highest output power in end-pumped bulk Yb:YAG ceramic laser.

  7. Neodymium-YAG laser core through urethrotomy in obliterative posttraumatic urethral strictures after failed initial urethroplasty.

    Science.gov (United States)

    Dogra, P N; Nabi, G

    2002-01-01

    To assess the feasibility, problems and results of Nd-YAG laser core through urethrotomy in the management of failed urethroplasty for posttraumatic bulbomembranous urethral strictures. 61 patients with obliterative posttraumatic urethral strictures were treated by Nd-YAG laser core through urethrotomy between May 1997 to April 2000. Of these, 5 patients had failed end-to-end urethroplasty done as an initial procedure at various periods of time. The procedure was performed as day care and patients were discharged within 6 h of procedure. At 24-30 months of follow-up, all patients are voiding well and are continent. Auxiliary procedures were required in 2 cases. Nd-YAG laser core through urethrotomy is a feasible day care option for patients of obliterative urethral strictures following failed initial urethroplasty with successful outcome. Copyright 2002 S. Karger AG, Basel

  8. Neodymium:YAG laser cutting of intraocular lens haptics in vitro and in vivo.

    Science.gov (United States)

    Feder, J M; Rosenberg, M A; Farber, M D

    1989-09-01

    Various complications following intraocular lens (IOL) surgery result in explantation of the lenses. Haptic fibrosis may necessitate cutting the IOL haptics prior to removal. In this study we used the neodymium: YAG (Nd:YAG) laser to cut polypropylene and poly(methyl methacrylate) (PMMA) haptics in vitro and in rabbit eyes. In vitro we were able to cut 100% of both haptic types successfully (28 PMMA and 30 polypropylene haptics). In rabbit eyes we were able to cut 50% of the PMMA haptics and 43% of the polypropylene haptics. Poly(methyl methacrylate) haptics were easier to cut in vitro and in vivo than polypropylene haptics, requiring fewer shots for transection. Complications of Nd:YAG laser use frequently interfered with haptic transections in rabbit eyes. Haptic transection may be more easily accomplished in human eyes.

  9. Localization of the pumping reflector for a Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kwang Suk; Kim, Chul Joong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-12-01

    For the first year plan of this program, the pumping reflectors, which are gold plated reflectors and ceramic diffuse reflectors, of the Nd:YAG laser have been localized. The laser output performances with these reflectors have been investigated. Developed reflectors can be applied successfully to our commercialized Nd:YAG laser which was worked in previous project. We designed the optical pumping system with GaAlAs diode laser bar to improve the pumping efficiency. Moreover, we investigated a simple pumping technique without changing the fleshlamp, which makes the Nd:YAG laser operate in a cw, a pulsed, and a mixed of the two mode. We expert many new applications of this diversification of output pulse shapes in industry and in medicine. 38 figs, 9 tabs, 18 refs. (Author).

  10. Study on growth techniques and macro defects of large-size Nd:YAG laser crystal

    Science.gov (United States)

    Quan, Jiliang; Yang, Xin; Yang, Mingming; Ma, Decai; Huang, Jinqiang; Zhu, Yunzhong; Wang, Biao

    2018-02-01

    Large-size neodymium-doped yttrium aluminum garnet (Nd:YAG) single crystals were grown by the Czochralski method. The extinction ratio and wavefront distortion of the crystal were tested to determine the optical homogeneity. Moreover, under different growth conditions, the macro defects of inclusion, striations, and cracking in the as-grown Nd:YAG crystals were analyzed. Specifically, the inclusion defects were characterized using scanning electron microscopy and energy dispersive spectroscopy. The stresses of growth striations and cracking were studied via a parallel plane polariscope. These results demonstrate that improper growth parameters and temperature fields can enhance defects significantly. Thus, by adjusting the growth parameters and optimizing the thermal environment, high-optical-quality Nd:YAG crystals with a diameter of 80 mm and a total length of 400 mm have been obtained successfully.

  11. Charged black holes in Hořava gravity

    International Nuclear Information System (INIS)

    Janiszewski, Stefan; Karch, Andreas; Robinson, Brandon; Sommer, David

    2014-01-01

    We explore static spherically symmetric black hole solutions allowing a bulk U(1) vector field in the khronometric formulation of Hořava gravity by way of Einstein-Æther. We examine analytic solutions and study numerical results in the limit that the khronon does not backreact on the metric

  12. Programme Note: Realities and Opportunities in Ho Chi Minh City.

    Science.gov (United States)

    Franchet, Chi Nguyen

    1996-01-01

    The current status of street children in Ho Chi Minh City, Vietnam, is characterized by marginalization from society through street vending, begging, theft, and prostitution. Evaluation of a drop-in center serving children without family linkages indicates need for needs assessments, follow-up activities, measurement of individual child progress,…

  13. Phase equilibria of the Mo-Al-Ho ternary system

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yitai; Chen, Xiaoxian; Liu, Hao [Guangxi Univ., Nanning (China). College of Materials Science and Engineering; Guangxi Univ., Nanning (China). Guangxi Key Laboratory of Processing for Non-ferrous Metal and Featured Materials; Zhan, Yongzhong [Guangxi Univ., Nanning (China). College of Materials Science and Engineering; Guangxi Univ., Nanning (China). Guangxi Key Laboratory of Processing for Non-ferrous Metal and Featured Materials; Guangxi Univ., Nanning (China). Center of Ecological Collaborative Innovation for Aluminum Industry

    2017-08-15

    Investigation into the reactions and phase equilibria of transition metal elements (i.e. Mo, Zr, Cr, V and Ti), Al and rare earths is academically and industrially important for the development of both refractory alloys and lightweight high-temperature materials. In this work, the equilibria of the Mo-Al-Ho ternary system at 773 K have been determined by using X-ray powder diffraction and scanning electron microscopy equipped with energy dispersive X-ray analysis. A new ternary phase Al{sub 4}Mo{sub 2}Ho has been found and the other ternary phase Al{sub 43}Mo{sub 4}Ho{sub 6} is observed. Ten binary phases in the Al-Mo and Al-Ho systems, including Al{sub 17}Mo{sub 4} rather than Al{sub 4}Mo, have been determined to exist at 773 K. The homogeneity ranges of AlMo{sub 3} and Al{sub 8}Mo{sub 3} phase are 7.5 at.% and 1 at.%, respectively. According to the phase-disappearing method, the maximum solubility of Al in Mo is about 16 at.%.

  14. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B.; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  15. Antiferromagnetism in a 20% Ho-80% Tb alloy single crystal

    DEFF Research Database (Denmark)

    Lebech, Bente

    1968-01-01

    20% Ho-80% Tb exhibits two magnetic phases, similar to those of Tb. The spiral turn angle varies from 31.1° to 21.4°. A minimum effective spin for the occurrence of stable simple ferromagnetic structure at low temperatures is predicted....

  16. Addition of HO-nucleophiles to free and coordinated nitriles

    International Nuclear Information System (INIS)

    Bokach, Nadejda A; Kukushkin, Vadim Yu

    2005-01-01

    The review surveys data on the addition of HO-nucleophiles (water, oximes, hydroxylamines, hydroxamic acids, alcohols) to nitriles. Main methods for C≡N bond activation in nucleophilic addition reactions are discussed. Particular attention is given to activation of nitriles through coordination to metal centres.

  17. Near IR Photolysis of HO2NO2: Supplemental Material

    Science.gov (United States)

    2002-01-01

    MkIV measurements of the volume mixing ratio (VMR) of HO2NO2 at 35 deg N, sunset on Sept. 25, 1993 are given. Measurements of HO2NO2 made between approx. 65 and 70 deg N, sunrise on May 8, 1997 are listed. The uncertainties given are 1 sigma estimates of the measurement precision. Uncertainty in the HO2NO2 line strengths is estimated to be 20%; this is the dominant contribution to the systematic error of the HO2NO2 measurement. Model inputs for the simulations are given. The albedos were obtained from Total Ozone Mapping Spectrometer reflectively data (raw data at ftp://jwocky.gsfc.nasa.gov) for the time and place of observation. Profiles of sulfate aerosol surface area ("Surf. Area") were obtained from monthly, zonal mean profiles measured by SAGE II [Thomason et al., 1997 updated via private communication]. The profile of Be(y) is based on the Wamsley et al. relation with N2O, using MkIV measurements of N20O. All other model inputs given are based on direct MkIV measurements. Finally, we note the latitude of the MkIV tangent point varied considerably during sunrise on May 8, 1997. The simulations shown here were obtained using different latitudes for each altitude.

  18. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2011-01-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  19. Analysis of n+165Ho and 169Tm reactions

    International Nuclear Information System (INIS)

    Young, P.G.; Arthur, E.D.; Philis, C.; Nagel, P.; Collin, M.

    1982-09-01

    Experimental data for neutron-induced reactions on 165 Ho and 169 Tm have been theoretically analyzed in preparation for calculations on the unstable isotopes of Tm. A set of deformed optical model parameters was determined from measurements of s- and p-wave neutron strength functions, total cross sections, elastic angular distributions, and 16-MeV proton scattering to the 165 Ho ground and first excited states. The parameters for the 165 Ho and 169 Tm nuclei were linked by means of an isospin term in the real and imaginary well depths, together with adjustment of the ν 2 and ν 4 deformation parameters based on systematics in this mass region. Transmission coefficients from this analysis were used in Hauser-Feshbach statistical model calculations of the 169 Tm(n,ν) cross section as well as the 169 Tm(n,2n) and (n,3n) cross sections to 23 MeV, after application of suitable preequilibrium corrections. The results of these calculations are in good agreement with most of the available experimental data on 165 Ho and 169 Tm

  20. Laser performance and modeling of RE3+:YAG double-clad crystalline fiber waveguides

    Science.gov (United States)

    Li, Da; Lee, Huai-Chuan; Meissner, Stephanie K.; Meissner, Helmuth E.

    2018-02-01

    We report on laser performance of ceramic Yb:YAG and single crystal Tm:YAG double-clad crystalline fiber waveguide (CFW) lasers towards the goal of demonstrating the design and manufacturing strategy of scaling to high output power. The laser component is a double-clad CFW, with RE3+:YAG (RE = Yb, Tm respectively) core, un-doped YAG inner cladding, and ceramic spinel or sapphire outer cladding. Laser performance of the CFW has been demonstrated with 53.6% slope efficiency and 27.5-W stable output power at 1030-nm for Yb:YAG CFW, and 31.6% slope efficiency and 46.7-W stable output power at 2019-nm for Tm:YAG CFW, respectively. Adhesive-Free Bond (AFB®) technology enables a designable refractive index difference between core and inner cladding, and designable core and inner cladding sizes, which are essential for single transverse mode CFW propagation. To guide further development of CFW designs, we present thermal modeling, power scaling and design of single transverse mode operation of double-clad CFWs and redefine the single-mode operation criterion for the double-clad structure design. The power scaling modeling of double-clad CFW shows that in order to achieve the maximum possible output power limited by the physical properties, including diode brightness, thermal lens effect, and simulated Brillion scattering, the length of waveguide is in the range of 0.5 2 meters. The length of an individual CFW is limited by single crystal growth and doping uniformity to about 100 to 200 mm lengths, and also by availability of starting crystals and manufacturing complexity. To overcome the limitation of CFW lengths, end-to-end proximity-coupling of CFWs is introduced.

  1. Effect of Nd:YAG laser on the solvent evaporation of adhesive systems.

    Science.gov (United States)

    Batista, Graziela Ribeiro; Barcellos, Daphne Câmara; Rocha Gomes Torres, Carlos; Damião, Álvaro José; de Oliveira, Hueder Paulo Moisés; de Paiva Gonçalves, Sérgio Eduardo

    2015-01-01

    This study evaluated the influence of Nd:YAG laser on the evaporation degree (ED) of the solvent components in total-etch and self-etch adhesives. The ED of Gluma Comfort Bond (Heraeus-Kulzer) one-step self-etch adhesive, and Adper Single Bond 2 (3M ESPE), and XP Bond (Dentsply) total-etch adhesives was determined by weight alterations using two techniques: Control--spontaneous evaporation of the solvent for 5 min; Experimental--Nd:YAG laser irradiation for 1 min, followed by spontaneous evaporation for 4 min. The weight loss due to evaporation of the volatile components was measured at baseline and after 10 s, 20 s, 30 s, 40 s, 50 s, 60 s, 70 s, 80 s, 90 s, 100 s, 110 s, 2 min, 3 min, 4 min, and 5 min. Evaporation of solvent components significantly increased with Nd:YAG laser irradiation for all adhesives investigated. Gluma Comfort Bond showed significantly higher evaporation of solvent components than Adper Single Bond 2 and XP Bond. All the adhesives lost weight quickly during the first min of Nd:YAG laser irradiation. The application of Nd:YAG laser on adhesives before light curing had a significant effect on the evaporation of the solvent components, and the ED of Gluma Comfort Bond one-step self-etch adhesive was significantly higher than with Adper Single Bond 2 and XP Bond total-etch adhesives. The use of the Nd:YAG laser on the uncured adhesive technique can promote a greater ED of solvents, optimizing the longevity of the adhesive restorations.

  2. Marginal microleakage in vitro study on class V cavities prepared with Er:YAG laser and etched with acid or etched with Er:YAG laser and acid; Estudo in vitro da microinfiltracao marginal em cavidades classe V preparadas com laser de Er:YAG e condicionadas com acido ou com laser de Er:YAG e acido

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Henrique Dutra Simoes

    2001-07-01

    Microleakage at the interface between the teeth and the restorative materials remains a problem with composite resin restorations. Microleakage at the gingival margins of class V cavities restorations still challenge as they are usually placed in dentin and/or cementum. Previous studies have shown that the cavity preparation with Er:YAG laser is possible. It has been reported that Er:YAG laser has ability to create irregular surface providing micromechanical retention for adhesive dental restorative materials and to improve marginal sealing. The purpose of this in vitro study was to evaluate the marginal microleakage on class V cavities prepared with Er:YAG laser and etched with acid or with Er:YAG laser and acid, in compared to those prepared and etched conventionally. Thirty human molars were divided into three groups, namely: group I - prepared with Er:YAG laser (KaVo KEY Laser II - Germany) and etched with 37% phosphoric acid; group II - prepared with Er:YAG laser and etched with Er:YAG laser and 37% phosphoric acid; group III (control group) - prepared with high speed drill and etched with 37% phosphoric acid. All cavities were treated with same adhesive system (Single Bond - 3M) and restored with the composite resin (Z100 - 3M), according to the manufacturer's instructions. The specimens were stored at 37 deg C in water for 24 hours, polished with Sof-Lex discs (3M), thermally stressed, sealed with a nail polish coating except for the area of the restoration and 1 mm around it, and immersed in a 50% aqueous solution of silver nitrate for 24 hours. After that, the specimens were rinsed in water, soaked in a photodeveloping solution and exposed to a fluorescent light for 8 hours. The teeth were embedded in an autopolymerizing resin and sectioned longitudinally using a diamond saw microtome under running water. The sections were photographed. The microleakage at the occlusal cavity and at the gingival margins of each specimen was evaluated with scores (0-3) by

  3. Morphological change study on root surfaces treated with curettes, sonic instruments or Er:YAG laser

    International Nuclear Information System (INIS)

    Guimaraes Filho, Arlindo Lopes

    2004-01-01

    Periodontal disease is caused by dental plaque and dental calculus on roots surfaces, specially on cervical areas. As dental plaque is the main cause and dental calculus a secondary one, it is practically impossible to separate one factor to the other one. In order to get periodontal tissue health it is necessary to eliminate dental plaque and calculus from root surfaces. In this sense, Er:YAG laser comes in as an excellent way to control periodontal disease, not only, by removing calculus and dental plaque but also for its bacteria reduction. The aim of this study is to compare, by S.E.M., root surfaces changing when they are treated with curettes and ultrasonic scaling or Er:YAG laser irradiation with two different energy levels of 60 mJ/pulse and 100 mJ/pulse and repetition tax of 10 Hz (in the display). It is also objective of this study to check a possible thermic damage to pulp tissue when the roots surfaces are irradiated with Er:YAG laser. We used for this study, five human dental roots, each one of them were cut into four samples, giving us a total of twenty samples, which were divided in five groups of four samples each one. The control group, we did not indicated any kind of treatment. The first group, the roots samples were scaled and planned with Gracey curettes 5/6 and 7/8. The second group, the roots samples were treated with ultrasonic instruments. The third group was irradiated with Er:YAG laser using 60 mJ/pulse , 10 Hz and energy density of 4 J/cm 2 (approximated). The fourth group was irradiated with Er:YAG laser using 100 mJ/pulse, 10 Hz and energy density of 7 J/cm 2 (approximated). The results analysis showed that roots scaling either with Gracey curettes or with ultrasonic instruments created smear layer covering roots surfaces; roots surfaces irradiated with Er:YAG laser showed few roughness in the third group; roots surfaces irradiated with Er:YAG laser showed no smear layer and the Er:YAG laser irradiation did not bring any thermic damage

  4. 885-nm laser diode array pumped ceramic Nd:YAG master oscillator power amplifier system

    Science.gov (United States)

    Yu, Anthony W.; Li, Steven X.; Stephen, Mark A.; Seas, Antonios; Troupaki, Elisavet; Vasilyev, Aleksey; Conley, Heather; Filemyr, Tim; Kirchner, Cynthia; Rosanova, Alberto

    2010-04-01

    The objective of this effort is to develop more reliable, higher efficiency diode pumped Nd:YAG laser systems for space applications by leveraging technology investments from the DoD and other commercial industries. Our goal is to design, build, test and demonstrate the effectiveness of combining 885 nm laser pump diodes and the use of ceramic Nd:YAG for future flight missions. The significant reduction in thermal loading on the gain medium by the use of 885 nm pump lasers will improve system efficiency.

  5. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    Science.gov (United States)

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  6. Characterization of Stone Cleaning by Nd:YAG Lasers with Different Pulse Duration

    International Nuclear Information System (INIS)

    Bartoli, L.; Siano, S.; Salimbeni, R.; Pouli, P.; Fotakis, C.

    2006-01-01

    The present work is a comparative study on the laser cleaning of stonework using Nd:YAG lasers at different pulse durations. The ablation rate, the degree of cleaning, and the appearance of the treated surface were studied irradiating a simulated sample and a real stone artefact using three different Nd:YAG laser systems with pulse duration of 90 microseconds, 15 nanoseconds, and 150 picoseconds. To our knowledge, the picosecond laser is here used for the first time in stone conservation. Differences in efficiency and in cleaning result are shown and discussed.

  7. Marginal microleakage in vitro study on class V cavities prepared with Er:YAG laser and etched with acid or etched with Er:YAG laser and acid; Estudo in vitro da microinfiltracao marginal em cavidades classe V preparadas com laser de Er:YAG e condicionadas com acido ou com laser de Er:YAG e acido

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, Henrique Dutra Simoes

    2001-07-01

    Microleakage at the interface between the teeth and the restorative materials remains a problem with composite resin restorations. Microleakage at the gingival margins of class V cavities restorations still challenge as they are usually placed in dentin and/or cementum. Previous studies have shown that the cavity preparation with Er:YAG laser is possible. It has been reported that Er:YAG laser has ability to create irregular surface providing micromechanical retention for adhesive dental restorative materials and to improve marginal sealing. The purpose of this in vitro study was to evaluate the marginal microleakage on class V cavities prepared with Er:YAG laser and etched with acid or with Er:YAG laser and acid, in compared to those prepared and etched conventionally. Thirty human molars were divided into three groups, namely: group I - prepared with Er:YAG laser (KaVo KEY Laser II - Germany) and etched with 37% phosphoric acid; group II - prepared with Er:YAG laser and etched with Er:YAG laser and 37% phosphoric acid; group III (control group) - prepared with high speed drill and etched with 37% phosphoric acid. All cavities were treated with same adhesive system (Single Bond - 3M) and restored with the composite resin (Z100 - 3M), according to the manufacturer's instructions. The specimens were stored at 37 deg C in water for 24 hours, polished with Sof-Lex discs (3M), thermally stressed, sealed with a nail polish coating except for the area of the restoration and 1 mm around it, and immersed in a 50% aqueous solution of silver nitrate for 24 hours. After that, the specimens were rinsed in water, soaked in a photodeveloping solution and exposed to a fluorescent light for 8 hours. The teeth were embedded in an autopolymerizing resin and sectioned longitudinally using a diamond saw microtome under running water. The sections were photographed. The microleakage at the occlusal cavity and at the gingival margins of each specimen was evaluated with scores (0

  8. Effects of a pulsed Nd:YAG laser on enamel and dentin

    Science.gov (United States)

    Myers, Terry D.

    1990-06-01

    Enamel and dentin samples were exposed extraorally to a pulsed neodymium yttriuma1uminumgarnet (Nd:YAG) laser. The lased samples were observed using both scanning electron microscopy and histological techniques to determine the effects of the laser. The present study has provided the following points: (1) Properly treated, enamel can be 1aser etched to a depth comparable to that achieved with phosphoric acid etching; and (2) both carious and noncarious dentin can be vaporized by the Nd:YAG laser. No cracking or chipping of any enamel or dentin sample was observed histologically or under the SEM.

  9. Aluminium alloys welding with high-power Nd:YAG lasers

    International Nuclear Information System (INIS)

    Garcia Orza, J.A.

    1998-01-01

    Aluminium alloys have good mechanical properties (high strength-to-weight ratio, corrosion resistance) and good workability. their applications are growing up, specially in the transportation industry. Weldability is however poorer than in other materials; recent advances in high power YAG laser are the key to obtain good appearance welds and higher penetration, at industrial production rates. Results of the combination of high power YAG beams with small fiber diameters and specific filler wires are presented. It is also characterized the air bone particulate material, by-product of the laser process: emission rates, size distribution and chemical composition are given for several aluminium alloys. (Author) 6 refs

  10. Transition of Emission Colours as a Consequence of Heat-Treatment of Carbon Coated Ce3+-Doped YAG Phosphors

    Directory of Open Access Journals (Sweden)

    Liang-Jun Yin

    2017-10-01

    Full Text Available To modify the luminescence properties of Ce3+-doped Y3Al5O12 (YAG phosphors, they have been coated with a carbon layer by chemical vapor deposition and subsequently heat-treated at high temperature under N2 atmosphere. Luminescence of the carbon coated YAG:Ce3+ phosphors has been investigated as a function of heat-treatment at 1500 and 1650 °C. The 540 nm emission intensity of C@YAG:Ce3+ is the highest when heated at 1650 °C, while a blue emission at 400–420 nm is observed when heated at 1500 °C but not at 1650 °C. It is verified by X-ray diffraction (XRD that the intriguing luminescence changes are induced by the formation of new phases in C@YAG:Ce3+-1500 °C, which disappear in C@YAG:Ce3+-1650 °C. In order to understand the mechanisms responsible for the enhancement of YAG:Ce3+ emission and the presence of the blue emission observed for C@YAG:Ce3+-1500 °C, the samples have been investigated by a combination of several electron microscopy techniques, such as HRTEM, SEM-CL, and SEM-EDS. This local and cross-sectional analysis clearly reveals a gradual transformation of phase and morphology in heated C@YAG:Ce3+ phosphors, which is related to a reaction between C and YAG:Ce3+ in N2 atmosphere. Through reaction between the carbon layer and YAG host materials, the emission colour of the phosphors can be modified from yellow, white, and then back to yellow under UV excitation as a function of heat-treatment in N2 atmosphere.

  11. Transition of Emission Colours as a Consequence of Heat-Treatment of Carbon Coated Ce3+-Doped YAG Phosphors.

    Science.gov (United States)

    Yin, Liang-Jun; Dierre, Benjamin; Sekiguchi, Takashi; van Ommen, J Ruud; Hintzen, Hubertus T Bert; Cho, Yujin

    2017-10-16

    To modify the luminescence properties of Ce 3+ -doped Y₃Al₅O 12 (YAG) phosphors, they have been coated with a carbon layer by chemical vapor deposition and subsequently heat-treated at high temperature under N₂ atmosphere. Luminescence of the carbon coated YAG:Ce 3+ phosphors has been investigated as a function of heat-treatment at 1500 and 1650 °C. The 540 nm emission intensity of C@YAG:Ce 3+ is the highest when heated at 1650 °C, while a blue emission at 400-420 nm is observed when heated at 1500 °C but not at 1650 °C. It is verified by X-ray diffraction (XRD) that the intriguing luminescence changes are induced by the formation of new phases in C@YAG:Ce 3+ -1500 °C, which disappear in C@YAG:Ce 3+ -1650 °C. In order to understand the mechanisms responsible for the enhancement of YAG:Ce 3+ emission and the presence of the blue emission observed for C@YAG:Ce 3+ -1500 °C, the samples have been investigated by a combination of several electron microscopy techniques, such as HRTEM, SEM-CL, and SEM-EDS. This local and cross-sectional analysis clearly reveals a gradual transformation of phase and morphology in heated C@YAG:Ce 3+ phosphors, which is related to a reaction between C and YAG:Ce 3+ in N₂ atmosphere. Through reaction between the carbon layer and YAG host materials, the emission colour of the phosphors can be modified from yellow, white, and then back to yellow under UV excitation as a function of heat-treatment in N₂ atmosphere.

  12. OH, HO2, and HO2* Radical Chemistry During PROPHET-AMOS 2016: Measurements and Model Comparison

    Science.gov (United States)

    Bottorff, B.; Lew, M.; Rickly, P.; Stevens, P. S.

    2017-12-01

    The hydroxyl (OH) and peroxy radicals, both the hydroperoxy radical (HO2) and organic peroxy radicals (RO2), play an important role in atmospheric chemistry. In addition to controlling lifetimes of many trace gases important to issues of global climate change, reactions of these radicals can also lead to the production of ozone and secondary organic aerosols in the atmosphere. Previous measurements of these radicals in remote forest environments have shown serious discrepancies with modeled concentrations. These results bring into question our understanding of the atmospheric chemistry of isoprene and other biogenic VOCs under low NOX conditions. In the summer of 2016, OH, HO2 and HO2* (HO2 + αRO2) radicals were measured using the Indiana University Laser-Induced Fluorescence Fluorescence Assay by Gas Expansion (LIF-FAGE) technique as part of the Program for Research on Oxidants: PHtochemistry, Emissions, and Transport- Atmospheric Measurements of Oxidants in Summer (PROPHET-AMOS). This campaign took place in a forested area in northern Michigan characterized by high mixing ratios of isoprene and low mixing ratios of NOX. Ambient measurements from this campaign will be compared to previous measurements at this site and to modeled predictions using both the Regional Atmospheric Chemistry Mechanism (RACM2) and the Master Chemical Mechanism. Potential interferences associated with the OH measurements will also be examined.

  13. Odhady absolutního kardiovaskulárního rizika v České republice

    Czech Academy of Sciences Publication Activity Database

    Reissigová, Jindra; Zvárová, Jana

    2008-01-01

    Roč. 88, č. 5 (2008), s. 288-292 ISSN 0032-6739 Institutional research plan: CEZ:AV0Z10300504 Keywords : framinghamská studie * SCORE studie * odhad kardiovaskulárního rizika * validační studie Subject RIV: BB - Applied Statistics, Operational Research

  14. SPF-RR sequential photothermal fractional resurfacing and remodeling with the variable pulse Er:YAG laser and scanner-assisted Nd:YAG laser.

    Science.gov (United States)

    Marini, Leonardo

    2009-12-01

    Many different lasers, polychromatic high-intensity light sources (PCLs), and RF devices have claimed clinical efficacy in rejuvenating the skin. In this study, the sequential combination of two different laser wavelengths was evaluated to produce reliably significant clinical improvements optimizing treatment parameters. The left volar aspects of the forearms of four volunteers were treated with nine different parameter settings using a variable pulsewidth fractional Er:YAG 2940-nm laser with and without air cooling. The pain perception level was recorded on a 0-10 point scale (0=No pain; 10=Most severe pain). Three evaluations were made: during treatment, immediately after treatment, and 5 minutes after treatment. The same investigation was made on the right volar aspects of the same four volunteers using a short-pulse, random pattern, 3-mm spot, scanner-assisted Nd-YAG 1064-nm laser at 0.3 ms pulsewidth at seven different parameter settings. Clinical evaluations were made concerning erythema and edema 3 days after treatment, as well as pre-operative and 60 days postoperative skin texture plus color uniformity. Considering that the majority of cosmetic patients are willing to accept a relatively short and uneventful downtime (2-4 days according to a study we are presently conducting) and do prefer to limit their intra- and postoperative pain to a minimum, the best combination of clinical improvement matching these two important parameters were selected for our study. A treatment strategy combining two sequential passes of long-pulse Nd:YAG laser (Nd:YAG-LP) at 0.3 and 35 ms followed by two passes of long-pulse fractional Er:YAG laser (Er:YAG-FT) at 600 micros was designed to treat the facial regions of 10 volunteers affected by a combination of intrinsic (chrono-) and extrinsic (mostly photo-) aging. The pain perception level was recorded on a 0-10 scale (0=No pain; 10=Most severe pain). Three evaluations were made: during, immediately after, and 5 minutes after

  15. UNS S32750 super duplex steel welding using pulsed Nd:YAG laser; Soldagem do aco superduplex UNS S32750 com laser pulsado Nd:YAG

    Energy Technology Data Exchange (ETDEWEB)

    Francini, O.D.; Andrade, G.G.; Clemente, M.S.; Gallego, J.; Ventrella, V.A., E-mail: ventrella@dem.feis.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Ilha Solteira, SP (Brazil). Departamento de Engenharia Mecanica

    2016-07-01

    Laser is a flexible and powerful tool with many relevant applications in industry, mainly in the welding area. Lasers today provide the welding industry technical solutions to many problems. This work studied the weld metal obtained by pulsed laser welding of Nd: YAG super duplex stainless steel UNS S32750 employed in the oil and natural gas, analyzing the influence of high cooling rate, due to the laser process, the swing phase ferrite / austenite. Were performed weld beads in butt joint with different repetition rates. The different microstructures were obtained by optical microscopy and scanning electron microscopy. The results showed that the effect of varying the welding energy of Nd: YAG laser on the volume fractions of the phases ferrite/austenite in the weld metal was its ferritization and low austenite amount on the grain boundary. (author)

  16. Isolation of {sup 163}Ho from dysprosium target material by HPLC for neutrino mass measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Veronika; Taylor, Wayne A.; Nortier, Francois M.; Engle, Jonathan W.; Pollington, Anthony D.; Kunde, Gerd J.; Rabin, Michael W.; Birnbaum, Eva R. [Los Alamos National Laboratory, Los Alamos, NM (United States). Chemistry Div.; Barnhart, Todd E.; Nickles, Robert J. [Univ. Wisconsinn, Madison, WI (United States). Dept. of Medical Physics

    2015-07-01

    The rare earth isotope {sup 163}Ho is of interest for neutrino mass measurements. This report describes the isolation of {sup 163}Ho from a proton-irradiated dysprosium target and its purification. A Dy metal target was irradiated with 16 MeV protons for 10 h. After target dissolution, {sup 163}Ho was separated from the bulk Dy via cation-exchange high performance liquid chromatography using 70 mmol dm{sup -3} α-hydroxyisobutyric acid as the mobile phase. Subsequent purification of the collected Ho fraction was performed to remove the α-hydroxyisobutyrate chelating agent and to concentrate the Ho in a low ionic strength aqueous matrix. The final solution was characterized by MC-ICP-MS to determine the {sup 163}Ho/{sup 165}Ho ratio, {sup 163}Ho and the residual Dy content. The HPLC purification process resulted in a decontamination factor 1.4 x 10{sup 5} for Dy. The isolated Ho fraction contained 24.8 ± 1.3 ng of {sup 163}Ho corresponding to holmium recovery of 72 ± 3%.

  17. Comparing particles for radiosynovectomy labeled with Ho-166

    International Nuclear Information System (INIS)

    Argueelles, M.G.; Luppi Berlanga, I.S.; Torres, E.A.; Pereyra Molina, V.

    2002-01-01

    Aim: Three types of microparticles containing Ho-166 were investigated as potential agents for radiation synovectomy. These are: hydroxyapatite (HA), ferric hydroxide macro-aggregates (FHMA) and polymeric micro-spheres (PM). Labeling was performed by three different methods: coprecipitation, two steps labeling using citrate and irradiation of Ho-165 complexed to acetylacetone (AcAc) incorporated into poly-L-lactic acid spheres (PLA) by the solvent evaporation technique. Material and methods: a coprecipitation technique of holmium hydroxide and ferric hydroxide was used in order to obtain 166 Ho-FHMA. Particle size was determined by optical microscopy and selective filtration (1.2 - 100 μm). Obtainment efficiency of FHMA was always higher than 90%. Radiochemical purity was checked by thin layer chromatography using ITLC/SG and EDTA solution as solvent. In vitro stability studies were performed by incubating labelled particles in either saline, or EDTA solution. Hydroxyapatite particles were prepared from the reaction of calcium nitrate and ammonia phosphate at high pH. By strong heating of the precipitate at 800 0 C, the product becomes largely anhydrous and hardened. The yield of the hydroxyapatite synthesis was always greater than 80%. Particle size range was studied using light microscopy. Labeling was done in two steps: 166Ho-citrate was prepared by adding sufficient citric acid to the 166 Ho-Cl 3 solution. The radioactive solution was added to the particulate suspension stirring continuously. Radiolabelled particles were rinsed and separated by centrifugation. Stable Ho-165, complexed to acetylacetone (AcAc), was incorporated into PLA spheres by the solvent evaporation technique. The particle size distribution of the micro-spheres was determined by electronic microscopy. A X-ray fluorescence technique was used to determine the percentage of 165 Ho-AcAc incorporated in the microspheres by studying standards and prepared PLA spheres. Stability studies were

  18. 1.8kW laser diode pumped YAG laser; Shutsuryoku 1.8kW no handotai laser reiki YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Toshiba Corporation, as a participant in Ministry of International Trade and Industry`s `photon measurement and processing technology project` since August, 1997, is engaged in the development of an energy-efficient LD (laser diode) pumped semiconductor YAG (yttrium-aluminum-garnet) laser device to be used for welding and cutting. It is a 5-year project and the goal is a mean output of 10kW and efficiency of 20%. In this article, a simulation program is developed which carries out calculation about element technology items such as the tracking of the beam from the pumping LD and the excitation distribution, temperature distribution, thermal stress distribution, etc., in the YAG rod. An oscillator is constructed, based on the results of the simulation, and it exhibits a world-high class continuous laser performance of a 1.8kW output and 13% efficiency. The record of 13% efficiency is five times higher than that achieved by the conventional lamp-driven YAG laser device. (translated by NEDO)

  19. Influence of Er:YAG and Nd:YAG wavelengths on laser-induced breakdown spectroscopy measurements under air or helium atmosphere

    International Nuclear Information System (INIS)

    Detalle, Vincent; Sabsabi, Mohamad; St-Onge, Louis; Hamel, Andre; Heon, Rene

    2003-01-01

    Laser-induced breakdown spectroscopy (LIBS) is widely dependent on the conditions of its implementation in terms of laser characteristics (wavelength, energy, and pulse duration), focusing conditions, and surrounding gas. In this study two wavelengths, 1.06 and 2.94 μm, obtained with Nd:YAG and Er:YAG lasers, respectively, were used for LIBS analysis of aluminum alloy samples in two conditions of surrounding gas. The influence of the laser wavelength on the laser-produced plasma was studied for the same irradiance by use of air or helium as a buffer gas at atmospheric pressure. We used measurements of light emission to determine the temporally resolved space-averaged electron density and plasma temperature in the laser-induced plasma. We also examined the effect of laser wavelength in two different ambient conditions in terms of spectrochemical analysis by LIBS. The results indicate that the effect of the surrounding gas depends on the laser wavelength and the use of an Er:YAG laser could increase linearity by limiting the leveling in the calibration curve for some elements in aluminum alloys. There is also a significant difference between the plasma induced by the two lasers in terms of electron density and plasma temperature

  20. Ho:YLF & Ho:LuLF slab amplifier system delivering 200 mJ, 2 µm single-frequency pulses

    CSIR Research Space (South Africa)

    Strauss, HJ

    2011-07-01

    Full Text Available A single-frequency single-pass amplifier based on Ho:YLF and Ho:LuLF in a scalable slab architecture delivering up to 210 mJ at 2064 nm is demonstrated. The amplifier was end-pumped by a 1890 nm Tm:YLF slab laser and was seeded with a 69 mJ single...

  1. Návrh slaďování pracovního a soukromého života ve vybrané organizaci

    OpenAIRE

    Majerčíková, Andrea

    2014-01-01

    Cílem diplomové práce je analyzovat strategii vybrané soukromé organizace v oblasti slaďování pracovního a osobního života a navrhnout opatření ke zlepšení stávajícího stavu. Práce specifikuje pojmy jako konflikt rolí v rámci pracovního a osobního života, gender a politika rovných příležitostí, koncept „flexicurity“ a dále nastiňuje různorodá opatření napomáhající slaďování pracovního a soukromého života. V rámci analýzy bylo využito dotazníkového šetření a rozhovoru s manažerkou vybrané orga...

  2. Optical characteristics of BaGa2S4:Ho3+ and BaGa2Se4:Ho3+ single crystals

    International Nuclear Information System (INIS)

    Choe, Sung-Hyu; Jin, Moon-Seog; Kim, Wha-Tek

    2005-01-01

    BaGa 2 S 4 , BaGa 2 S 4 :Ho 3+ , BaGa 2 Se 4 , and BaGa 2 Se 4 :Ho 3+ single crystals were grown by using the chemical transport reaction method. The optical energy gaps of the single crystals were investigated in the temperature region from 11 K to 300 K. The temperature dependence of the optical energy gap was well fitted by the Varshni equation. Two broad emission bands were observed in the photoluminescence spectra of the single crystals. These bands were attributed to donor-acceptor pair recombinations. Sharp emission peaks were observed in the BaGa 2 S 4 :Ho 3+ and the BaGa 2 Se 4 :Ho 3+ single crystals and were assigned to radiation recombination between split Stark levels of Ho 3+ .

  3. Implant Surface Temperature Changes during Er:YAG Laser Irradiation with Different Cooling Systems.

    Directory of Open Access Journals (Sweden)

    Abbas Monzavi

    2014-04-01

    Full Text Available Peri-implantitis is one of the most common reasons for implant failure. Decontamination of infected implant surfaces can be achieved effectively by laser irradiation; although the associated thermal rise may cause irreversible bone damage and lead to implant loss. Temperature increments of over 10ºC during laser application may suffice for irreversible bone damage.The purpose of this study was to evaluate the temperature increment of implant surface during Er:YAG laser irradiation with different cooling systems.Three implants were placed in a resected block of sheep mandible and irradiated with Er:YAG laser with 3 different cooling systems namely water and air spray, air spray alone and no water or air spray. Temperature changes of the implant surface were monitored during laser irradiation with a K-type thermocouple at the apical area of the fixture.In all 3 groups, the maximum temperature rise was lower than 10°C. Temperature changes were significantly different with different cooling systems used (P<0.001.Based on the results, no thermal damage was observed during implant surface decontamination by Er:YAG laser with and without refrigeration. Thus, Er:YAG laser irradiation can be a safe method for treatment of periimplantitis.

  4. Bioceramic hydroxyapatite coating fabricated on TI-6Al-4V using Nd:YAG Laser

    CSIR Research Space (South Africa)

    Tlotleng, Monnamme

    2014-11-01

    Full Text Available Driven Innovation, 15th Annual International Conference, Stellenbosch, South Africa, 6-7 November 2014 Bioceramic hydroxyapatite coating fabricated on TI-6Al-4V using Nd:YAG Laser M. Tlotleng1, 4*, E. Akinlabi1, M. Shukla2, 3, S. Pityana4, T...

  5. Taladrado de pizarra mediante láser de Nd:Yag

    Directory of Open Access Journals (Sweden)

    Larosi, M. S.

    1998-04-01

    Full Text Available A serie of experiments to investigate the feasibility of using a Nd: YAG laser to process slate tiles and the influence of the processing parameters have been undertaken. The objective of this work is to investigate the capabilities of a Nd:YAG pulsed laser to drill tiny holes in slate tiles, in order to produce a better quality drilled slate tile in a reduced time. Part of the results obtained in a systematic study about the influence of the processing parameters, such as average power, pulse width, frequency, pressure and type of assisting gas is presented.

    Se ha desarrollado una serie de experimentos para investigar la viabilidad del uso de un láser de Nd: YAG para el procesamiento de piezas de pizarra, así como los parámetros que más afectan al proceso. El objetivo concreto de este trabajo es investigar la capacidad de un láser de Nd:YAG pulsado para taladrar orificios de pequeño diámetro en láminas de pizarra, con el fin de obtener mejor calidad de taladrado en un tiempo reducido. Se presenta parte de los resultados obtenidos en un estudio sistemático de la influencia de los parámetros de procesamiento en la forma del orificio, tales como, potencia, duración de pulso, frecuencia, presión y tipo de gas de aportación.

  6. Passive Q switching of a solar-pumped Nd:YAG laser.

    Science.gov (United States)

    Lando, M; Shimony, Y; Noter, Y; Benmair, R M; Yogev, A

    2000-04-20

    Passive Q switching is a preferable choice for switching the Q factor of a solar-pumped laser because it requires neither a driver nor an electrical power supply. The superior thermal characteristics and durability of Cr(4+):YAG single crystals as passive Q switches for lamp and diode-pumped high-power lasers has been demonstrated. Here we report on an average power of 37 W and a switching efficiency of 80% obtained by use of a solar-pumped Nd:YAG laser Q switched by a Cr(4+):YAG saturable absorber. Concentration of the pumping solar energy on the laser crystal was obtained with a three-stage concentrator, composed of 12 heliostats, a three-dimensional compound parabolic concentrator (CPC) and a two-dimensional CPC. The water-cooled passive Q switch also served as the laser rear mirror. Repetition rates of as much as 50 kHz, at pulse durations between 190 and 310 ns (FWHM) were achieved. From the experimental results, the saturated single-pass power absorption of the Cr(4+):YAG device was estimated as 3 ? 1%.

  7. High-power pulsed and CW diode-pumped mode-locked Nd:YAG lasers

    Science.gov (United States)

    Marshall, Larry R.; Hays, A. D.; Kaz, Alex; Kasinski, Jeff; Burnham, R. L.

    1991-01-01

    The operation of both pulsed and CW diode-pumped mode-locked Nd:YAG lasers are presented. The pulsed laser produced 1.0 mJ with pulsewidths of 90 psec at 20 Hz. The CW pumped laser produced 6 W output at 1.064 microns and 3 W output at 532 nm.

  8. In vitro studies of morphological changes in enamel surface after Er:YAG and Nd:YAG laser irradiation, by SEM; Estudo in vitro do efeito do laser Nd:YAG e Er:YAG sobre o esmalte dental humano atraves de microscopia eletronica de varredura

    Energy Technology Data Exchange (ETDEWEB)

    Verlangieri, Eleonora Jaeger

    2001-07-01

    The caries prevention by using laser irradiation has been investigated by many authors using various lasers with different irradiations conditions. The purpose of this study was to investigated the morphological changes in enamel surface after Er:YAG and Nd:YAG laser irradiation, in vitro, by SEM. Fifteen freshly extracted, intact, caries-free, human third molars, were used in this study. The coronary portions were sectioned, from buccal to lingual direction, in two half-parts. Each one was irradiated by a different laser. The first one was irradiated with water-air spray, by a Nd:YAG laser, at 1.084 nm wave length, at 10 W, 10 Hz, 100 mJ for 60 sec., with an optical fiber in contact mode (0,32 mm of diameter); and the other half, with water-air spray by an Er:YAG laser at 2,94 micrometers wave length at the parameters of 4 Hz, 80 mJ, 24.95 J/cm{sup 2} for 60 sec. The results of this study suggested that both lasers promoted morphological changes in the enamel surface enhancing resistance and can be an alternative clinical method for caries preventions. (author)

  9. High-power Nd:YAG lasers using stable-unstable resonators

    CERN Document Server

    Mudge, D; Ottaway, D J; Veitch, P J; Munch, J P; Hamilton, M W

    2002-01-01

    The development of a power-scalable diode-laser-pumped continuous-wave Nd:YAG laser for advanced long-baseline interferometric detectors of gravitational waves is described. The laser employs a chain of injection-locked slave lasers to yield an efficient, frequency-stable, diffraction-limited laser beam.

  10. Passively model-locked Nd: YAG laser with a component GaAs

    International Nuclear Information System (INIS)

    Zhang Zhuhong; Qian Liejia; Chen Shaohe; Fan Dianyuan; Mao Hongwei

    1992-01-01

    An all solid-state passively mode-locked Nd: YAG laser with a 400 μm, (100) oriented GaAs component is reported for the first time and model locked pulses with a duration of 16 ps, average energy of 10 μJ were obtained with a probability of 90%

  11. Nd : YAG surgical laser effects in canine prostate tissue: temperature and damage distribution

    NARCIS (Netherlands)

    van Nimwegen, S. A.; L'Eplattenier, H. F.; Rem, A. I.; van der Lugt, J. J.; Kirpensteijn, J.

    2009-01-01

    An in vitro model was used to predict short-term, laser-induced, thermal damage in canine prostate tissue. Canine prostate tissue samples were equipped with thermocouple probes to measure tissue temperature at 3, 6, 9 and 12 mm depths. The tissue surface was irradiated with a Nd:YAG laser in contact

  12. Nd:YAG laser in urogenital surgery of the dog and cat

    NARCIS (Netherlands)

    van Nimwegen, S.A.

    2008-01-01

    It was hypothesized that the fiber-guided Nd:YAG laser with its incisional and hemostatic action, could be useful for meticulous tissue dissection in a subcapsular partial prostatectomy in dogs, and in laparoscopic surgery of dogs and cats. Prior to clinical use, its action was investigated in

  13. 5.4W cladding-pumped Nd:YAG silica fiber laser

    OpenAIRE

    Yoo, S.; Webb, A.S.; Standish, R.J.; May-Smith, T.C.; Sahu, J.K.

    2012-01-01

    We report on the spectroscopy and laser characteristics of Nd-doped fiber, fabricated by rod-in-tube from Nd:YAG as a core material with silica cladding. A cladding-pumped CW laser operation at 1058nm with 52% slope-efficiency is demonstrated.

  14. Insights into the energy transfer mechanism in Ce3+-Yb3+ codoped YAG phosphors

    NARCIS (Netherlands)

    Yu, D. C.; Rabouw, F. T.|info:eu-repo/dai/nl/413318036; Boon, W. Q.; Kieboom, T.; Ye, S.; Zhang, Q. Y.; Meijerink, A.|info:eu-repo/dai/nl/075044986

    2014-01-01

    Two distinct energy transfer (ET) mechanisms have been proposed for the conversion of blue to near-infrared (NIR) photons in YAG:Ce3+,Yb3+. The first mechanism involves downconversion by cooperative energy transfer, which would yield two NIR photons for each blue photon excitation. The second

  15. Generation of ultra short pulses by auto injection in the Nd: YAG laser

    International Nuclear Information System (INIS)

    Faria, I.C. de.

    1986-01-01

    Yhe work presented here, was concerned to the construction of a coherent light source in the near infrared region with pulses of 10 -10 seconds. The auto-injection technique was employed for generating these short pulses with posterior extraction of the pulse applied to a Nd=YAG-pulsed laser. (author) [pt

  16. Efficient delivery of 60 J pulse energy of long pulse Nd:YAG laser ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Most of today's industrial Nd:YAG lasers use fibre-optic beam delivery. In such lasers, fibre core diameter is an important consideration in deploying a beam delivery system. Using a smaller core diameter fibre allows higher irradiances at focus position, less degradation of beam quality, and a larger ...

  17. Efficient delivery of 60 J pulse energy of long pulse Nd:YAG laser ...

    Indian Academy of Sciences (India)

    2014-02-09

    Feb 9, 2014 ... Most of today's industrial Nd:YAG lasers use fibre-optic beam delivery. ... optical fibre and successfully delivered up to 60 J of pulse energy with .... and electrical pump input to laser output conversion efficiency is about 5%. ... [3] W Koechner, Solid state laser engineering, 5th edn (Springer, Berlin, 1999).

  18. Luminescence properties of YAG:Nd nano-sized ceramic powders ...

    Indian Academy of Sciences (India)

    Abstract. Nano-sized ceramic powders with weaker aggregation of Nd3+-doped yttrium aluminum garnet. (YAG:Nd3+) were synthesized via co-microemulsion and microwave heating. This method provides a limited small space in a micelle for the formation of nano-sized precursors. It also requires a very short heating time, ...

  19. In vitro study of the variable square pulse Er:YAG laser cutting efficacy for apicectomy.

    Science.gov (United States)

    Grgurević, Josko; Grgurević, Lovro; Miletić, Ivana; Karlović, Zoran; Krmek, Silvana Jukić; Anić, Ivica

    2005-06-01

    Variable square pulse (VSP) Er:YAG laser should be quicker than older Er:YAG lasers. The objectives were: (1) comparison of VSP laser and mechanical handpiece efficacy for apicectomy and (2) determination of optimal pulse width/energy/frequency combination. Sixty extracted, single-rooted mature human teeth with round apical parts were instrumented, root filled, cleaned, and divided into four groups. Apical 2 mm of each root were apicectomized with mechanical handpiece and Er:YAG laser with three different settings (LaserA = 200 mJ/300 microseconds/ 8 Hz; LaserB = 200 mJ/100 microseconds/8 Hz; LaserC = 380 mJ/100 microseconds/20 Hz). Timing results were statistically compared. LaserC was the most efficient setting. Differences between groups were significant except between LaserC-Mechanical and LaserA-LaserC (P < 0.05). VSP Er:YAG laser used for apicectomy is slower by a factor of 7-31 than mechanical handpiece, but treatment outcome is acceptable. Optimal settings for apicectomy with VSP laser are 380 mJ/100 microseconds/20 Hz. Copyright 2005 Wiley-Liss, Inc.

  20. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    Science.gov (United States)

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  1. Micro machining workstation for a diode pumped Nd:YAG high brightness laser system

    NARCIS (Netherlands)

    Kleijhorst, R.A.; Offerhaus, Herman L.; Bant, P.

    1998-01-01

    A Nd:YAG micro-machining workstation that allows cutting on a scale of a few microns has been developed and operated. The system incorporates a telescope viewing system that allows control during the work and a software interface to translate AutoCad files. Some examples of the performance are

  2. Shift and broadening of emission lines in Nd :YAG laser crystal ...

    Indian Academy of Sciences (India)

    1Department of Optics and Laser Engineering, Estahban Branch, Islamic Azad ... Nd3+:YAG crystal; heat generation; three-level emission lines; four-level emission ... Modelling of high-power solid-state lasers requires precise knowledge of ...

  3. SEM analysis of enamel surface treated by Er:YAG laser: influence of irradiation distance.

    Science.gov (United States)

    Souza-Gabriel, A E; Chinelatti, M A; Borsatto, M C; Pécora, J D; Palma-Dibb, R G; Corona, S A M

    2008-07-01

    Depending on the distance of laser tip to dental surface a specific morphological pattern should be expected. However, there have been limited reports that correlate the Er:YAG irradiation distance with dental morphology. To assess the influence of Er:YAG laser irradiation distance on enamel morphology, by means of scanning electron microscopy (SEM). Sixty human third molars were employed to obtain discs (approximately =1 mm thick) that were randomly assigned to six groups (n=10). Five groups received Er:YAG laser irradiation (80 mJ/2 Hz) for 20 s, according to the irradiation distance: 11, 12, 14, 16, or 17 mm and the control group was treated with 37% phosphoric acid for 15 s. The laser-irradiated discs were bisected. One hemi-disc was separated for superficial analysis without subsequent acid etching, and the other one, received the phosphoric acid for 15 s. Samples were prepared for SEM. Laser irradiation at 11 and 12 mm provided an evident ablation of enamel, with evident fissures and some fused areas. At 14, 16 and 17 mm the superficial topography was flatter than in the other distances. The subsequent acid etching on the lased-surface partially removed the disorganized tissue. Er:YAG laser in defocused mode promoted slight morphological alterations and seems more suitable for enamel conditioning than focused irradiation. The application of phosphoric acid on lased-enamel surface, regardless of the irradiation distance, decreased the superficial irregularities.

  4. Thermal lensing effects in cw-pumped Nd3: YAG laser rods

    International Nuclear Information System (INIS)

    Chang, C.

    Thermal lensing effects were investigated in cw-pumped Nd 3+ : YAG laser rods. For identically specified rods very different thermally induced focal lengths were measured. Thus compensation of thermal lensing by applying curved end faces should be done individually for each rod. (orig.) 891 HT/orig. 892 HIS

  5. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    Science.gov (United States)

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  6. 101 W of average green beam from diode-side-pumped Nd:YAG ...

    Indian Academy of Sciences (India)

    Nd:YAG rod laser using 18 mm long type-II phase-matched LBO crystal in a ... LBO crystal are placed in the parallel arms of the Z-shaped cavity formed by .... than its maximum possible value as the higher-order modes could not reach the.

  7. New long-wavelength Nd:YAG laser at 1.44 micron: effect on brain.

    Science.gov (United States)

    Martiniuk, R; Bauer, J A; McKean, J D; Tulip, J; Mielke, B W

    1989-02-01

    A wavelength-shifted Nd:YAG laser, tuned to coincide with the infrared absorption peak of water at 1.44 microns, was used to make lesions in normal rabbit brain. A total of 48 lesions were made with power up to 20 W, with energy up to 40 joules, and with two different spot sizes. These lesions were compared to lesions made with 1.06 microns radiation from an Nd:YAG laser under identical operating conditions. Measurements of blood-brain barrier damage and width, depth, and volume of tissue affected were obtained 30 minutes after placement of the lesions. It was found that 1.44-microns lesions produced photoevaporative tissue loss at the highest intensities used. The layer of coagulated tissue remaining after photovaporization had a mean thickness of 0.6 mm irrespective of the volume of tissue removed. There was no photovaporization in the 1.06-microns lesions. In addition, the amount of peripheral edema per unit volume of tissue coagulated was approximately half at the 1.44-microns wavelength. These findings suggest that the 1.44-microns Nd:YAG laser may be a useful surgical instrument since it combines the photoevaporative effect of the CO2 laser while maintaining the advantages of the conventional Nd:YAG laser (quartz fiber delivery and effective hemostasis).

  8. Removal effects of the Nd:YAG laser and Carisolv on carious dentin.

    Science.gov (United States)

    Yamada, Y; Hossain, M; Kawanaka, T; Kinoshita, J; Matsumoto, K

    2000-10-01

    The purpose of this study was to investigate the removal effect of the Nd:YAG laser irradiation and Carisolv on carious dentin. Many previous studies have reported several simple and alternative techniques, such as lasers and chemicals, for caries removal. Carisolv was applied on the surface of 20 extracted human anterior and molar teeth for 1 min and then the Nd:YAG laser was irradiated with a continuous water spray for another 1 min. The energy densities were varied from 2 to 6W with a repetition rate of 20 pps. As caries removal progressed, the cavity was carefully assessed by DIAGNOdent. Each lesion was photographed before and after treatment, and the treated cavity was observed microscopically using a stereoscope and with scanning electron microscope (SEM). Thermal change at the time of laser irradiation was measured by thermovision. Our results revealed that application of Carisolv followed by Nd:YAG laser irradiation at 4-6W pulse energy effectively removed dentin caries. The total procedure was usually repeated once or twice for complete caries removal. From the SEM study, it was found that the cavity surface treated with the laser revealed various patterns of microirregularity, often accompanied by microfissure propagation. There was also no smear layer. It was revealed that Nd:YAG laser and Carisolv could provide an alternative technique for caries removal instead of the conventional mechanical drilling and cutting.

  9. High efficiency laser action in mildly doped Yb:LuYAG ceramics

    Czech Academy of Sciences Publication Activity Database

    Pirri, A.; Toci, G.; Li, J.; Xie, T.; Pan, Y.; Babin, Vladimir; Beitlerová, Alena; Nikl, Martin; Vannini, M.

    2017-01-01

    Roč. 73, Nov (2017), s. 312-318 ISSN 0925-3467 Institutional support: RVO:68378271 Keywords : laser ceramic s * Yb laser * mixed garnets * LuYAG Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.238, year: 2016

  10. Yttrium aluminum garnet (YAG) obtained by rare-earth mixed oxide (RE2O3)

    International Nuclear Information System (INIS)

    Castro, D.F.; Daguano, J.K.M.F.; Rodrigues Junior, D.; Suzuki, P.A.; Silva, O.M.M.

    2010-01-01

    In this work, the substitution of commercial Y 2 O 3 by a rare earth mixed oxide, RE 2 O 3 , to form Yttrium aluminum Garnet-Y 3 Al 5 O 12 , was investigated. Al 2 O 3 :Y 2 O 3 and Al 2 O 3 :RE 2 O 3 powder-mixtures, in a molar ratio of 60:40, were milled and subsequently cold uniaxially-pressed. Compacts were sintered at 1000, 1400 or 1600 deg C, for 120 minutes. RE 2 O 3 oxide was characterized by high-resolution synchrotron X-ray diffraction (HRXRD) and compared to Y 2 O 3 . X-ray diffraction pattern of the RE 2 O 3 indicates a true solid solution formation. Rietveld refinement of the sintered YAG and (RE)AG reveled a similar crystal structure to the YAGs obtained by the use of Al 2 O 3 -Y 2 O 3 or Al 2 O 3 -RE 2 O 3 respectively. Microstructural analysis of both, YAG or (RE)AG, revealed similar grain sizes of about 2.5 μm besides mechanical properties, with hardness of 400HV and fracture toughness of 3.8MPa.m1/2. It could be, thus, demonstrated that pure Y 2 O 3 can be substituted by the rare-earth solid solution, RE 2 O 3 , in the formation YAGs, presenting similar microstructural and mechanical properties. (author)

  11. Latest MIG, TIG arc-YAG laser hybrid welding systems for various welding products

    Science.gov (United States)

    Ishide, Takashi; Tsubota, Shuho; Watanabe, Masao

    2003-03-01

    Laser welding is capable of high-efficiency low-strain welding, and so its applications are started to various products. We have also put the high-power YAG laser of up to 10 kW to practical welding use for various products. On the other hand the weakest point of this laser welding is considered to be strict in the welding gap aiming allowance. In order to solve this problem, we have developed hybrid welding of TIG, MIG arc and YAG laser, taking the most advantages of both the laser and arc welding. Since the electrode is coaxial to the optical axis of the YAG laser in this process, it can be applied to welding of various objects. In the coaxial MIG, TIG-YAG welding, in order to make irradiation positions of the YAG laser beams having been guided in a wire or an electrode focused to the same position, the beam transmitted in fibers is separated to form a space between the separated beams, in which the laser is guided. With this method the beam-irradiating area can be brought near or to the arc-generating point. This enables welding of all directions even for the member of a three-dimensional shape. This time we carried out welding for various materials and have made their welding of up to 1 mm or more in welding groove gap possible. We have realized high-speed 1-pass butt welding of 4m/min in welding speed with the laser power of 3 kW for an aluminum alloy plate of approximately 4 mm thick. For a mild steel plate also we have realized butt welding of 1m/min with 5 kW for 6 mm thick. Further, in welding of stainless steel we have shown its welding possibility, by stabilizing the arc with the YAG laser in the welding atmosphere of pure argon, and shown that this welding is effective in high-efficiency welding of various materials. Here we will report the fundamental welding performances and applications to various objects for the coaxial MIG, TIG-YAG welding we have developed.

  12. Evaluation of the permeability and morphological alteration of the dental surface after apicoectomy, treatment and preparation with Er:YAG and Nd:YAG lasers; Avaliacao da permeabilidade e da alteracao morfologica da superficie dentinaria apos apicectomia, tratamento e retropreparo com os lasers de Er:YAG e Nd:YAG

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Rodrigo Guerra de

    2001-07-01

    One of the objectives of endodontic treatment is to resolve pathological periapical processes caused by microbial contamination of the dental pulp. Correct execution of the necessary chemical preparation prior to surgery generally results in positive outcomes. However, a percentage of cases do not respond favorably and therefore require retreatment, a conservative therapeutic option. There are meanwhile a number of treatment failures which do not respond to these conservative measures and must therefore be subjected to paraendodontic surgical procedures. One of the principal problems of this therapeutic conduct is linked to the surface permeability of the dentin after apicoectomy and the lack of adequate marginal adaptation between the retrofilling material and the cavity walls. This permits the percolation of microorganisms and their metabolic by products from the system of root canals to the periapical region, thereby compromising the necessary tissue repair. The present work proposes the evaluation of the surface and marginal permeability of cut dentin after apicoectomy and treatment with Er:YAG and Nd:YAG lasers with fiber optics and then retrofilled with intermediate restorative material (IRM). A total of 24 single rooted teeth whose canals were endodontically treated were divided into 3 experimental groups: group I, whose apices were sectioned with an Er:YAG laser and the resulting cavity and the cut dental surface were irradiated with this laser via a 50/10 type fiber; in group II the apicoectomy was conducted with an Er:YAG laser and the resulting cavity and the cut surface were irradiated with a Nd:YAG laser; in group III, the samples were apicoectomized and the cavities were treated with a high speed bur (control group). Analysis of the infiltration of the dye methylene blue throughout the cut dental surface and the reconstruction demonstrated that the samples in the irradiated groups presented lower indices of infiltration than the control group. The

  13. Upconversion dynamics in Yb3+-Ho3+-doped fluoroindate glasses

    International Nuclear Information System (INIS)

    Martin, I.R.; Rodriguez, V.D.; Lavin, V.; Rodriguez-Mendoza, U.R.

    1998-01-01

    The mechanisms and dynamics of the upconversion emissions in Yb 3+ -Ho 3+ -doped fluoroindate glasses by exciting at 975 nm have been analysed. The upconversion efficiencies have been measured as a function of temperature in the range from 12 to 295 K. The temporal evolution of the 545- and 650-nm upconversion emissions obtained under flash excitation at 975 nm in codoped samples with 2.25 mol.% of Yb 3+ and 0.75 mol.% of Ho 3+ cannot be described using the energy migration model. This indicates that at this concentration of Yb 3+ the rapid migration regimen between these ions has not been reached. A model is proposed in order to explain the temporal evolution of these emissions taking into account energy migration between donors and backtransfer processes. (orig.)

  14. Effect of Er:YAG laser irradiation on bonding property of zirconia ceramics to resin cement.

    Science.gov (United States)

    Lin, Yihua; Song, Xiaomeng; Chen, Yaming; Zhu, Qingping; Zhang, Wei

    2013-12-01

    This study aimed to investigate whether or not an erbium: yttrium-aluminum-garnet (Er:YAG) laser could improve the bonding property of zirconia ceramics to resin cement. Surface treatments can improve the bonding properties of dental ceramics. However, little is known about the effect of Er:YAG laser irradiated on zirconia ceramics. Specimens of zirconia ceramic pieces were made, and randomly divided into 11 groups according to surface treatments, including one control group (no treatment), one air abrasion group, and nine Er:YAG laser groups. The laser groups were subdivided by applying different energy intensities (100, 200, or 300 mJ) and irradiation times (5, 10, or 15 sec). After surface treatments, ceramic pieces had their surface morphology observed, and their surface roughness was measured. All specimens were bonded to resin cement. Shear bond strength was measured after the bonded specimens were stored in water for 24 h, and additionally aged by thermocycling. Statistical analyses were performed using one way analysis of variance (ANOVA) and Tukey's test for shear bond strength, and Dunnett's t test for surface roughness, with α=0.05. Er:YAG laser irradiation changed the morphological characteristics of zirconia ceramics. Higher energy intensities (200, 300 mJ) could roughen the ceramics, but also caused surface cracks. There were no significant differences in the bond strength between the control group and the laser groups treated with different energy intensities or irradiation times. Air abrasion with alumina particles induced highest surface roughness and shear bond strength. Er:YAG laser irradiation cannot improve the bonding property of zirconia ceramics to resin cement. Enhancing irradiation intensities and extending irradiation time have no benefit on the bond of the ceramics, and might cause material defect.

  15. 2940-nm Er:YAG fractional laser enhanced the effect of topical drug for psoriasis.

    Science.gov (United States)

    Li, Ruilian; Zhou, Jun; Su, Hui; Wang, Mei; Wang, Yongxian; Xiao, Shengxiang; Ma, Huiqun

    2017-08-01

    We observed the promoting effects of the 2940-nm erbium:YAG (Er:YAG) fractional laser in topical drug delivery for psoriasis. A total of five (four males and one female) recalcitrant psoriasis patients were given laser treatment eight times at 1-week intervals with the following parameters: 5-11% spot density and 100-μm energy depth. The psoriatic skin lesions on the left knee and the corresponding lesions at the right ones of each psoriasis patient were randomly divided into two groups: laser + topical drug group (L) and drug alone group (D). The psoriatic lesions in both groups were treated with the same topical treatment (calcipotriol ointment). The corresponding psoriatic lesions in the L group received extra 2940-nm Er:YAG laser irradiation before topical treatment. The photos of psoriatic lesions were taken before each treatment. The final photos were obtained from the patients at the seventh day after the final treatment. Drug alone or in combination with laser Er:YAG both reduced psoriatic lesions. However, with the increase in the number of treatments, increasing differences were observed between the treatment and the control sides. The therapeutic outcomes in the L groups were better than those in the D groups. Psoriasis area and severity index (PASI) scores for five cases of both groups were decreased. However, the scores in the L groups were lower than those in the D groups. The use of 2940 nm Er:YAG promoted the absorption of topical drugs for psoriasis, improving the therapeutic effect.

  16. Potential emerging treatment in vitiligo using Er:YAG in combination with 5FU and clobetasol.

    Science.gov (United States)

    Mokhtari, Fatemeh; Bostakian, Anis; Shahmoradi, Zabihollah; Jafari-Koshki, Tohid; Iraji, Fariba; Faghihi, Gita; Hosseini, Sayed Mohsen; Bafandeh, Behzad

    2018-04-01

    Vitiligo is a pigmentary disorder of skin affecting at least 1% of the world population of all races in both sexes. Its importance is mainly due to subsequent social and psychological problems rather than clinical complications. Various treatment choices are available for vitiligo; however, laser-based courses have shown to give more acceptable results. The aim of this trial was to evaluate the efficacy of Er:YAG laser as a supplementary medicine to topical 5FU and clobetasol in vitiligo patients. Two comparable vitiligo patches from 38 eligible patients were randomized to receive topical 5FU and clobetasol in control group and additional Er:YAG laser in intervention group. Major outcomes of interest were the size of patch and pigmentation score at randomization and 2 and 4 months after therapy. Final sample included 18 (47%) male patients and age of 35.66±8.04. The performance Er:YAG group was superior in all sites. Reduction in the size of patches was greater in Er:YAG group (p-value=.004). Also, this group showed a higher pigmentation scores in the trial period than control group (p-value<.001). Greater reduction in the size and increase in pigmentation score was seen in Er:YAG group especially for short periods after therapy and repeating laser sessions may help improving final outcomes. Er:AYG could help in reducing complications of long-term topical treatments, achieving faster response, and improving patient adherence. © 2017 Wiley Periodicals, Inc.

  17. Evaluation of the cavity margins after Er:YAG laser ablation of the enamel and dentin

    Science.gov (United States)

    Dostalova, Tatjana; Krejsa, Otakar; Jelinkova, Helena; Hamal, Karel

    1994-12-01

    This study investigates the checks of cavity margin after enamel and dentin ablation. The Er:YAG laser enamel and dentin ablation can be directly connected with the danger of cracks originating in the enamel near the cavity. This study evaluates the quality of the enamel edges after Er:YAG laser preparation. The enamel and dentin of buccal surfaces were ablated by the Er:YAG laser radiation. An Erbium:YAG laser system with the energy of 200 mJ was used to generate 200 microsecond(s) long pulses of mid-infrared 2.94 micrometers light in multimode configuration. The laser was operating in a free running mode, the repetition rate being 0.5 Hz with average laser power of 100 mW. Laser radiation was focused on the tooth tissue. Water cooling was used during the procedure in order to prevent tooth tissue destruction. The time of laser preparation was 5 minutes. A cavity of class V was prepared. The teeth were immersed into 0.5% basic fuchsin and then centrifuged at 6000 rev/min for 20 minutes. The microphotographs of the margins stained with 0.5% basic fuchsin were made and then the longitudinal section of the teeth were evaluated. The micrographs of the longitudinal section were checked and measured afterwards. The effect of the investigated laser irradiation on the origin of cracks was analyzed in the scanning electron microscope. Micrographs of each tooth before and after the laser ablation were compared. Micrographs of the intact teeth after extraction present the cracks of the enamel. They depend on the pressure exerted during extraction. The influence of the laser ablation proper is it bears no signs of new cracks. The conclusions of this study demonstrate the non-invasive nature of the Er:YAG laser ablation of the hard dental tissues.

  18. Polarized neutron capture in polarized 59Co and 165Ho nuclei

    International Nuclear Information System (INIS)

    Bosman, J.J.

    1976-01-01

    Gamma spectroscopy on the reactions 59 Co(n,γ) 60 Co and 165 Ho(n,γ) 166 Ho with polarized neutrons and polarized targets enabled the assignment of spins to 36 levels in 60 Co and 15 levels in 166 Ho. Several of them had not been reported earlier. The techniques used to polarize neutron beams and targets and the gamma-spectroscopy are extensively discussed

  19. Spectroscopic analysis of LiHoF4 and LiErF4

    DEFF Research Database (Denmark)

    Christensen, H.P.

    1979-01-01

    The polarized absorption spectra for Ho3+ and Er3+ in LiHoF4 and LiErF4, respectively, have been recorded in the spectral interval 4000-26 000 cm-1 at 2 K. Parts of the spectra were examined at higher temperatures. The experimental levels for Ho3+ and Er3+ in LiRF4 were close to those found in Li...

  20. HoTbTi2O7, the mixtures of spin ice and spin liquid

    International Nuclear Information System (INIS)

    Chang, L.J.; Terashita, H.; Schweika, W.; Chen, Y.Y.; Gardner, J.S.

    2007-01-01

    Polycrystalline samples of Ho 2- x Tb x Ti 2 O 7 (x=0.5, 1, and 1.5) have been prepared and characterized. No long-range order is observed for HoTbTi 2 O 7 in magnetization and specific heat measurements down to 2 K. The low-energy magnetic excitation measurements suggests that HoTbTi 2 O 7 possesses both characteristics of spin ice and spin liquid in the ground state

  1. Insights into the photochemical transformation pathways of triclosan and 2′-HO-BDE-28

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Ya-nan; Xie, Qing; Chen, Jingwen, E-mail: jwchen@dlut.edu.cn; Li, Yingjie; Fu, Zhiqiang

    2015-12-30

    Highlights: • Direct photolysis of anionic HO-PXDEs occurs through excited singlet states. • Dioxin products are formed from excited singlet states of HO-PXDEs. • Self-sensitized photolysis is involved in the phototransformation of HO-PXDEs. • {sup 1} O{sub 2} and ·OH can be generated in energy or electron transfer reactions between excited HO-PXDEs and dissolved O{sub 2}. - Abstract: Hydroxylated polyhalogenated diphenyl ethers (HO-PXDEs) have been recognized as a group of widely detected emerging contaminants in natural waters. Photolysis was proved to be an important transformation pathway for these compounds and their direct phototransformation results in highly toxic dioxins. However, the roles of excited states and reactive oxygen species in the photochemical transformation of these compounds are still unclear. In this study, 2′-HO-2,4,4′-trichlorodiphenyl ether (triclosan) and 2′-HO-2,4,4′-tribromodiphenyl ether (2′-HO-BDE-28) were selected as model compounds to investigate their phototransformation processes. Results showed that the direct photolysis reactions of both triclosan and 2′-HO-BDE-28 occurred via their respective excited singlet states, leading to the generation of dioxins. In addition, the energy and electron transfer reactions between excited states of model compounds and molecular O{sub 2} can lead to the generation of {sup 1}O{sub 2} and ·OH, which results in self-sensitized photolysis. We also found that both the k, Φ dioxin yield for anionic triclosan were higher than those of anionic 2′-HO-BDE-28. This study revealed the roles of the excited states in direct photolysis and the generation pathway of reactive oxygen species in self-sensitized photolysis of HO-PXDEs, which is important for understanding the phototransformation mechanisms of HO-PXDEs.

  2. Consumer Behaviour. Case: iPhone Ho Chi Minh City

    OpenAIRE

    Tran, Thi Xuan Oanh

    2016-01-01

    The main aim of this thesis is to figure out the factors that have influenced consumer behaviour of young iPhone users in Ho Chi Minh City. In this study, the author draw a conclusion based on the data collected from the survey and proposed some feasible recommendations for Apple and other high-end smartphone companies to understand their consumers and enhance brand equity. For the secondary data, a variety of theories, including consumers’ characteristics, promotion and the decision mak...

  3. Identical gamma-vibrational bands in {sup 165}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Radford, D.C.; Galindo-Uribarri, A.; Janzen, V.P. [Chalk River Labs., Ontario (Canada)] [and others

    1996-12-31

    The structure of {sup 165}Ho at moderate spins has been investigated by means of Coulomb excitation. Two {gamma}-vibrational bands (K{sup {pi}} = 11/2{sup {minus}} and K{sup {pi}} = 3/2{sup {minus}}) are observed, with very nearly identical in-band {gamma}-ray energies. Gamma-ray branching ratios are analyzed to extract information on Coriolis mixing, and the role of the K quantum number in identical bands is discussed.

  4. Temperature Variation of the Magnetic Structure of HoSb

    DEFF Research Database (Denmark)

    Andersen, Nils Axel; Kjems, Jørgen; Vogt, O.

    1980-01-01

    Neutron diffraction has been used to show that the magnetic moment vector in the antiferromagnet HoSb changes direction as a function of temperature below TN=5.7K. The experimental results are in qualitative agreement with a recent theoretical prediction by Jensen et al. (1980) which ascribe the ...... the changing directions to a competition between the crystal fields and the dipolar interactions....

  5. Spectroscopic characterization of Ho3+ ion-doped fluoride glass

    International Nuclear Information System (INIS)

    Florez, A.; Oliveira, S.L.; Florez, M.; Gomez, L.A.; Nunes, L.A.O.

    2006-01-01

    Among the new optical materials available, fluoride glass, which has an extended transmission window, is emerging as an important material for use in optical fibers, lasers, sensors, etc. Here, we analyze the spectroscopic properties of Ho 3+ ions in a fluoroindate glass based on absorption measurements. Ho 3+ -doped fluoroindate glass with the composition (40 - x)InF 3 -20SrF 2 -20ZnF 2 -16BaF 2 -2GdF 3 -2NaF-xHoF 3 , x = 1.0, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0, 8.0 and 9.0 mol%, was prepared under an argon atmosphere. Absorption spectra in the range 300-2200 nm were then obtained. The experimental oscillator strength f Exp. was calculated from the areas under absorption bands. Using Judd-Ofelt theory and least-squares fitting, the phenomenological intensity parameter Ω λ (λ = 2, 4, 6) and the theoretical oscillator strength f Cal. were calculated. To evaluate potential applications and to analyze the properties of Ho 3+ ions in these host glasses, the following spectroscopy parameters were calculated: the transition probability between multiplets A JJ' , the branching ratio β JJ' , the radiative lifetime τ R , the peak cross-section for stimulated emission σ p , and the emitting-level multiphonon rate W NR for each band. The results were compared with those reported in the literature for similar glasses of the same concentration

  6. Resonantly diode-pumped continuous-wave and Q-switched Er:YAG laser at 1645 nm.

    Science.gov (United States)

    Chang, N W H; Simakov, N; Hosken, D J; Munch, J; Ottaway, D J; Veitch, P J

    2010-06-21

    We describe an efficient Er:YAG laser that is resonantly pumped using continuous-wave (CW) laser diodes at 1470 nm. For CW lasing, it emits 6.1 W at 1645 nm with a slope efficiency of 36%, the highest efficiency reported for an Er:YAG laser that is pumped in this manner. In Q-switched operation, the laser produces diffraction-limited pulses with an average power of 2.5 W at 2 kHz PRF. To our knowledge this is the first Q-switched Er:YAG laser resonantly pumped by CW laser diodes.

  7. Atmospheric measurements of OH, HO2 and NO by laser-induced fluorescence spectroscopy using a compact all solid-state laser system

    Science.gov (United States)

    Bloss, W. J.; Floquet, C.; Gravestock, T. J.; Heard, D. E.; Ingham, T.; Johnson, G. P.; Lee, J. D.

    2003-04-01

    Free-radicals are key intermediates that control the budgets of many trace gases, for example ozone, greenhouse gases and harmful pollutants. Measurement of radicals and comparison with model calculations constitutes an important test of our understanding of the underlying chemistry. There is a greater need for compact and lightweight instruments for the in situ measurement of free-radical species that are suitable for deployment from a number of field-platforms. A new field instrument has been developed that incorporates an all solid-state Nd:YAG pumped titanium sapphire laser that is capable of generating radiation at high pulse-repetition-frequency for the detection of OH, HO_2, NO and IO radicals in the atmosphere by laser induced fluorescence (LIF). The system offers advantages of wide wavelength tunability, compactness, low weight, greater long-term stability (fibre-optic delivery) and short warm-up time. The instrument was successfully deployed during 2002 in the NAMBLEX field campaign at Mace Head with detection limits for OH and HO_2 (measured simultaneously with laser operation at 308 nm) of 3.1 x 10^5 molecule cm-3 (0.012 ppt) and 2.6 x 10^6 molecule cm-3 (0.09 pptv) respectively. Diurnal profiles of OH have been recorded over a period of 5 weeks. NO controls the HO_2/OH ratio and is the critical parameter in the production of tropospheric ozone, yet measurements in the boundary layer are restricted to a single indirect technique based on chemiluminescent analysers. Measurements of NO in the atmosphere have been made by LIF using the new instrument operating at 226 nm, with absolute concentrations in good agreement with simultaneous measurements made using a commercial chemiluminescent analyser. Whilst operating at 445 nm, the instrument has detected the IO radical in the laboratory, with a projected detection limit that is well below previously measured atmospheric concentrations of IO. A second instrument to be deployed on an aircraft platform is

  8. Separation and implantation of the rare isotope {sup 163}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Kieck, Tom; Chrysalidis, Katerina; Dorrer, Holger; Kormannshaus, Stefan; Schmidt, Sebastian; Schneider, Fabian; Wendt, Klaus [JGU Mainz (Germany); Duellmann, Christoph [JGU Mainz (Germany); GSI Darmstadt (Germany); Gamer, Lisa; Gastaldo, Loredana [Universitaet Heidelberg (Germany); Collaboration: ECHo-Collaboration

    2016-07-01

    The ECHo collaboration aims at measuring the electron neutrino mass by recording the spectrum following electron capture of {sup 163}Ho. To reach a sub-eV sensitivity, a large number of individual microcalorimeters is needed, into which the isotope must be implanted in a well-controlled manner. The necessary amount of {sup 163}Ho is produced by neutron irradiation of enriched {sup 162}Er in the ILL high flux reactor. This introduces significant contaminations of other radioisotopes, which have to be quantitatively removed both, by chemical and mass spectrometric separation. The application of resonance ionization at the RISIKO mass separator guarantees the required isotope selectivity for purification and suitable energy for ion implantation. The efficiency and stability of the laser ion source was improved by Finite-Element Analysis of the thermal processes. For optimum implantation into the detector pixels (170 x 170 μm{sup 2}) with minimum losses a small ion beam spot at the implantation site is needed. For this purpose, post focusing ion optics were installed. Simulations were performed in order to optimize the homogeneous distribution of the implanted ions. The necessity to alternate implantation phases with deposition of a thin metallic layer for {sup 163}Ho activities larger than 10 Bq is being discussed.

  9. Automatizace domácího mikropivovaru

    OpenAIRE

    Širůček, Pavel

    2015-01-01

    Práce pojednává o základech technologie výroby piva a surovinách pro výrobu piva potřebných, domácích mikropivovarech, základních postupech a principech užívaných v těchto pivovarech a jejich použití. Dále se věnuje konkrétnímu řešení zvoleného mikropivovaru, jeho návrhu, sestavení a automatizaci, včetně popisu řídícího softwaru. Zvolený mikropivovar je troj nádobový, k ohřevu je použit plynový hořák a přečerpávání zajišťuje čerpadlo. Jako řídící jednotka slouží programovatelný automat PLC LO...

  10. Návrh a implementace internetového obchodu

    OpenAIRE

    Maťák, Lubomír

    2010-01-01

    Obsahem této práce je analýza a návrh elektronického obchodu pro firmu, zabývající se velkoobchodním prodejem elektromateriálu a poskytování služeb v oblasti dodávek elektromateriálu na stavbu různých projektů, jak ze státního, tak ze soukromého sektoru. Nejedná se o klasický internetový obchod formou B2C. Koncept této práce je navržen jako B2B. Hlavní myšlenkou je online komunikace dodavatele a odběratele a možná kontrola, jak stavu zakázky, tak stavu skladu pro případné další objednávky. ...

  11. Fluctuations in a Hořava-Lifshitz bouncing cosmology

    International Nuclear Information System (INIS)

    Gao, Xian; Wang, Yi; Xue, Wei; Brandenberger, Robert

    2010-01-01

    Hořava-Lifshitz gravity is a potentially UV complete theory with important implications for the very early universe. In particular, in the presence of spatial curvature it is possible to obtain a non-singular bouncing cosmology. The bounce is realized as a consequence of higher order spatial curvature terms in the gravitational action. Here, we extend the study of linear cosmological perturbations in Hořava-Lifshitz gravity coupled to matter in the case when spatial curvature is present. As in the case without spatial curvature, we find that there is no extra dynamical degree of freedom for scalar metric perturbations. We study the evolution of fluctuations through the bounce and show that the solutions remain non-singular throughout. If we start with quantum vacuum fluctuations on sub-Hubble scales in the contracting phase, and if the contracting phase is dominated by pressure-less matter, then for λ = 1 and in the infrared limit the perturbations at late times are scale invariant. Thus, Hořava-Lifshitz gravity can provide a realization of the ''matter bounce'' scenario of structure formation

  12. Model elektronického obchodu pro služby

    OpenAIRE

    Zechmeisterová, Věra

    2009-01-01

    Obsahem práce je vytvoření modelu informačního zabezpečení služeb autoopravny a vytvoření odpovídajícího systémového řešení elektronického obchodování této autoopravny. The content of this Master thesis is the creation of the car repair shop services informational security model and also the creation of commensurate e-commerce system solution for this car repair shop. A

  13. Diode-Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-Micrometers Laser

    Science.gov (United States)

    2015-09-01

    Schematic of the 800-nm diode pumped Tm/Ho composite fiber laser 8 Under quasi-continuous wave (Q- CW ) pumping conditions of 1-ms duration and a...Fig. 9 (Top) Schematic of the 800-nm diode -pumped Tm/Ho composite fiber laser with outcoupler. (Left) Q- CW laser performance of the Tm/Ho composite...ARL-TR-7452 ● SEP 2015 US Army Research Laboratory Diode -Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-μm Laser by G

  14. The mass of the electron neutrino and electron capture in 163Ho

    International Nuclear Information System (INIS)

    Yasumi, S.; Rajasekaran, G.; Ando, M.; Ochiai, F.; Ikeda, H.; Ohta, T.; Stefan, P.M.; Maruyama, M.; Nashimoto, N.; Fujioka, M.; Ishii, K.; Shinozuka, T.; Sera, K.; Omori, T.; Izawa, G.; Yagi, M.; Masumoto, K.; Shima, K.

    1983-01-01

    To determine the mass of the electron neutrino, electron capture in 163 Ho was studied. From the intensity of M X-rays and the total number of 163 Ho atoms in a source, as determined by the PIXE method, the partial M-capture half life of 163 Ho was estimated to be (4.5 +- 1.5) x 10 4 yr. A relation between the Q-value of 163 Ho and the mass of the electron neutrino was obtained. (orig.)

  15. [hHO-1 structure prediction and its mutant construct, expression, purification and activity analysis].

    Science.gov (United States)

    Xia, Zhen Wei; Cui, Wen Jun; Zhou, Wen Pu; Zhang, Xue Hong; Shen, Qing Xiang; Li, Yun Zhu; Yu, Shan Chang

    2004-10-01

    Human Heme Oxygenase-1 (hHO-1) is the rate-limiting enzyme in the catabolism reaction of heme, which directly regulates the concentration of bilirubin in human body. The mutant structure was simulated by Swiss-pdbviewer procedure, which showed that the structure of active pocket was changed distinctly after Ala25 substituted for His25 in active domain, but the mutated enzyme still binded with heme. On the basis of the results, the expression vectors, pBHO-1 and pBHO-1(M), were constructed, induced by IPTG and expressed in E. coli DH5alpha strain. The expression products were purified with 30%-60% saturation (NH4)2SO4 and Q-Sepharose Fast Flow column chromatography. The concentration of hHO-1 in 30%-60% saturation (NH4)2SO4 components and in fractions through twice column chromatography was 3.6-fold and 30-fold higher than that in initial product, respectively. The activity of wild hHO-1 (whHO-1) and mutant hHO-1 (deltahHO-1) showed that the activity of deltahHO-1 was reduced 91.21% compared with that of whHO-1. The study shows that His25 is of importance for the mechanism of hHO-1, and provides the possibility for effectively regulating the activity to exert biological function.

  16. The effect of Ho to the flux pinning and microstructure of powder melting process Y(Ho)BCO samples

    International Nuclear Information System (INIS)

    Liu Peng; Chao Xixu; Shi Zhiqiang; Zhao Zhongxiang

    1994-01-01

    Magnetic relaxation and magnetization are measured for powder melting Y 1-x Ho x Ba 2 Cu 3 O 7 (x = 0.2, 0.4, and 0.6) samples within a wide temperature range. The pinning potential U and magnetization critical current densities J c are obtained according to the theory of Anderson and Kim and Bean's model. It is found that both U and J c are a affected by the addition of the rare-earth element Ho. In the sample with x = 0.4 the pinning potential U and the critical current J c have maximum values when the magnetic field is parallel to the c-axis. An unusual behaviour of U as a function of temperature T, which may be related to the pinning potential distribution in the sample is observed. (orig.)

  17. Fine Structure in Proton Emission from the Deformed 141g.sHo and 141mHo

    International Nuclear Information System (INIS)

    Karny, M.; Rykaczewski, Krzysztof Piotr; Grzywacz, R.; Batchelder, J.C.; Bingham, C.R.; Goodin, C. T.; Gross, Carl J.; Hamilton, J.H.; Korgul, A.; Krolas, W.; Liddick, S. N.; Li, K.; Maier, Karl; Mazzocchi, C.; Piechaczek, A.; Shapira, Dan; Simpson, D.; Tantawy, M.N.; Winger, J.A.; Yu, Chang-Hong; Zganjar, E. F.

    2007-01-01

    Fine structure in proton emission from the deformed states 141g.s Ho (T 1/2 = 4.1 ms) and 141 mHo (T 1/2 = 7.4 (micro)s) has been discovered at Oak Ridge by detecting fusion evaporation residues with the Recoil Mass Spectrometer, Si-detectors and digital signal processing electronics. The branching ratios to the first 2 + excited state in 140 Dy were measured to be I p g.s. (2 + ) = 0.9±0.1% and I p m (2 + ) = 1.7±0.5%. A comparison of the available calculations to the experimental values calls for further development of the theoretical models

  18. The effect of pre-operative topical anaesthetic cream on the ablative width and coagulative depth of ablative fractional resurfacing laser.

    Science.gov (United States)

    Punyaratabandhu, Preawphan; Wanitphakdeedecha, Rungsima; Pattanaprichakul, Penvadee; Sitthinamsuwan, Panitta; Phothong, Weeranut; Eimpunth, Sasima; Lohsiriwat, Visnu; Manuskiatti, Woraphong

    2017-02-01

    Topical anaesthetic cream (TAC) is commonly used as a pre-treatment of ablative fractional resurfacing (AFR) laser. Most of anaesthetic cream contains distilled water as major component. Therefore, pre-operative TAC may interfere the photothermal reaction in the skin treated with fractional carbon-dioxide (FCO 2 ) laser and fractional erbium-doped yttrium aluminium garnet (FEr:YAG) laser. The objective of the study was to compare the ablative width (AW) and coagulative depth (CD) of AFR laser with and without pre-treatment with TAC. Four Thai females who underwent abdominoplasty were included in the study. The excised skin of each subject was divided into four areas. TAC (eutectic mixture of local anaesthesia; EMLA) with 1-h occlusion was applied only on the first and second areas. The first and third areas were treated with FCO 2 at 15 mj and 5% density. The second and fourth areas were treated with FEr:YAG at 28 J/cm 2 and 5% density. Six biopsied specimens were obtained from each area. A total of 96 specimens (24 specimens from each area) were collected from four patients and examined randomly by two dermatopathologists. The ablative width and coagulative depth from each specimen were determined. In FCO 2 -treated specimens, the mean AW of the specimens that were pre-treated with TAC and control was 174.86 ± 24.57 and 188.52 ± 41.32 μm. The mean CD of the specimens that were pre-treated with TAC and control was 594.96 ± 111.72 and 520.03 ± 147.40 μm. There were no significant differences in AW and CD between both groups (p = 0.53 and p = 0.15). In FEr:YAG-treated specimens, the mean AW of the specimens that were pre-treated with TAC and control was 381.11 ± 48.02 and 423.65 ± 60.16 μm. The mean CD of the specimens that were pre-treated with TAC and control was 86.03 ± 29.44 and 71.59 ± 18.99 μm. There were no significant differences in AW and CD between both groups (p = 0.16 and p = 0.24). The pre

  19. Návrh podnikatelského plánu pro vznik a rozvoj vybraného podniku

    OpenAIRE

    Kropáček, Lukáš

    2014-01-01

    Hlavním cílem předkládané absolventské práce je vytvořit návrh podnikatelského záměru pro vznik a další rozvoj minipivovaru. The main goal of the thesis is to propose a business plan for establishment and development of a microbrewery. A

  20. Shear Bond Strength of Composite and Ceromer Superstructures to Direct Laser Sintered and Ni-Cr-Based Infrastructures Treated with KTP, Nd:YAG, and Er:YAG Lasers: An Experimental Study.

    Science.gov (United States)

    Gorler, Oguzhan; Hubbezoglu, Ihsan; Ulgey, Melih; Zan, Recai; Guner, Kubra

    2018-04-01

    The aim of this study was to examine the shear bond strength (SBS) of ceromer and nanohybrid composite to direct laser sintered (DLS) Cr-Co and Ni-Cr-based metal infrastructures treated with erbium-doped yttrium aluminum garnet (Er:YAG), neodymium-doped yttrium aluminum garnet (Nd:YAG), and potassium titanyl phosphate (KTP) laser modalities in in vitro settings. Experimental specimens had four sets (n = 32) including two DLS infrastructures with ceromer and nanohybrid composite superstructures and two Ni-Cr-based infrastructures with ceromer and nanohybrid composite superstructures. Of each infrastructure set, the specimens randomized into four treatment modalities (n = 8): no treatment (controls) and Er:YAG, Nd:YAG, and KTP lasers. The infrastructures were prepared in the final dimensions of 7 × 3 mm. Ceromer and nanohybrid composite was applied to the infrastructures after their surface treatments according to randomization. The SBS of specimens was measured to test the efficacy of surface treatments. Representative scanning electron microscopy (SEM) images after laser treatments were obtained. Overall, in current experimental settings, Nd:YAG, KTP, and Er:YAG lasers, in order of efficacy, are effective to improve the bonding of ceromer and nanohybrid composite to the DLS and Ni-Cr-based infrastructures (p laser is more effective in the DLS/ceromer infrastructures (p laser, as second more effective preparation, is more effective in the DLS/ceromer infrastructures (p laser modalities, in order of success, Nd:YAG, KTP, and Er:YAG, are effective to increase bonding of these structures.

  1. Luminescent properties of LuAG:Yb and YAG:Yb single crystalline films grown by Liquid Phase Epitaxy method

    International Nuclear Information System (INIS)

    Zorenko, Yu; Zorenko, T.; Gorbenko, V.; Voznyak, T.; Popielarski, P.; Batentschuk, M.; Osvet, A.; Brabec, Ch; Kolobanov, V.; Spasky, D.; Fedorov, A.

    2016-01-01

    In this work, investigation of the spectroscopic parameters of the luminescence of Yb"3"+ ions in single crystalline films of Lu_3Al_5O_1_2 and Y_3Al_5O_1_2 garnets was performed using the synchrotron radiation excitation with the energy in the range of Yb"3"+ charge transitions (CT), exciton range and the onset of interband transitions of these garnets. The basic spectroscopic parameters of the Yb"3"+ CT luminescence in LuAG and YAG hosts were determined and summarized with taking into account the differences in the band gap structure of these garnets. - Highlights: • Single crystalline films of Yb doped LuAG and YAG garnets were grown by LPE method. • Yb"3"+ luminescence of LuAG:Yb and YAG:Yb film were studied using synchrotron radiation. • Basic parameters of Yb"3"+ charge transfer luminescence in LuAG and YAG were determined.

  2. Biostimulative effects of Nd:YAG Q-switch dye on normal human fibroblast cultures: study of a new chemosensitizing agent for the Nd:YAG laser

    International Nuclear Information System (INIS)

    Castro, D.J.; Saxton, R.E.; Fetterman, H.R.; Castro, D.J.; Ward, P.H.

    1987-01-01

    Kodak Q-switch II is a new chemical with an absorption maxima at 1051 nm, designed to be used as an Nd:YAG dye laser. The potential for this dye as a new chemosensitizing agent in the treatment of connective tissue diseases and wound healing with low energy Nd:YAG laser was examined. Two normal fibroblast cell lines were tested for sensitivity to various levels of this dye in vitro. These cells were exposed to Q-switch II dye at concentrations of 0.01, 0.1, 1, 10, 50, and 100 micrograms/ml for 1 and 24 hours. Cell viability was assessed by the trypan blue exclusion test. Cell duplication and DNA synthesis were measured by the incorporation of [ 3 H]-thymidine at 6 and 24 hours postexposure to Q-switch II dye. At concentrations up to 10 micrograms/ml, both cell lines tested showed no changes in cell viability. However, at concentrations equal or higher than 50 micrograms/ml, more than 40% of the fibroblasts incorporated trypan blue after 24 hours of exposure to this dye, indicating significant cell destruction. The results indicate that Q-switch II dye is nontoxic to normal human fibroblast cultures and showed significant biostimulative effects on cell duplication at concentrations equal to or lower than 10 micrograms/ml. Further studies will be required to determine the usefulness of Q-switch II dye as a new photochemosensitizing agent for potential biostimulation of wound healing and/or treatment of connective tissue diseases with the Nd:YAG laser (near infrared, 1060 nm) at nonthermal levels of energies

  3. Extratumoral Heme Oxygenase-1 (HO-1 Expressing Macrophages Likely Promote Primary and Metastatic Prostate Tumor Growth.

    Directory of Open Access Journals (Sweden)

    Sofia Halin Bergström

    Full Text Available Aggressive tumors induce tumor-supporting changes in the benign parts of the prostate. One factor that has increased expression outside prostate tumors is hemoxygenase-1 (HO-1. To investigate HO-1 expression in more detail, we analyzed samples of tumor tissue and peritumoral normal prostate tissue from rats carrying cancers with different metastatic capacity, and human prostate cancer tissue samples from primary tumors and bone metastases. In rat prostate tumor samples, immunohistochemistry and quantitative RT-PCR showed that the main site of HO-1 synthesis was HO-1+ macrophages that accumulated in the tumor-bearing organ, and at the tumor-invasive front. Small metastatic tumors were considerably more effective in attracting HO-1+ macrophages than larger non-metastatic ones. In clinical samples, accumulation of HO-1+ macrophages was seen at the tumor invasive front, almost exclusively in high-grade tumors, and it correlated with the presence of bone metastases. HO-1+ macrophages, located at the tumor invasive front, were more abundant in bone metastases than in primary tumors. HO-1 expression in bone metastases was variable, and positively correlated with the expression of macrophage markers but negatively correlated with androgen receptor expression, suggesting that elevated HO-1 could be a marker for a subgroup of bone metastases. Together with another recent observation showing that selective knockout of HO-1 in macrophages reduced prostate tumor growth and metastatic capacity in animals, the results of this study suggest that extratumoral HO-1+ macrophages may have an important role in prostate cancer.

  4. Efectividad del Nd- Yag láser en la capsulotomía posterior Effectiveness of Nd-Yag laser in posterior capsulotomy

    Directory of Open Access Journals (Sweden)

    Alina Pedroso Llanes

    2004-06-01

    Full Text Available Este trabajo se propuso determinar la efectividad del neodimio YAG láser (Nd-YAG láser en la realización de capsulotomía posterior a 150 pacientes (ojos operados de catarata senil o presenil en el centro de Microcirugía Ocular en Serie del Hospital Oftalmológico Docente "Ramón Pando Ferrer" en el período comprendido de febreroa diciembre de 1999. En este grupo se analizaron como variables la edad, sexo, raza, implante o no de lente intraocular, tipo de opacidad de cápsula posterior, agudeza visual con corrección pre y postratamiento, complicaciones encontradas, comportamiento de la presión intraocular, así como la energía empleada para realizar dicho proceder. Estos datos se analizaron a través de tablas de contingencias Chi cuadrado. Como resultado de esta investigación se encontró que el láser es altamente efectivo para el mejoramiento de la agudeza visual en los pacientes afectados de catarata secundaria (74,7 %. Se observó además aumento transitorio de la presión intraocular en las dos primeras horas posteriores al láser (60,7 %, y no se encontró ninguna complicación que afectara la visión de los ojos estudiadosThe aim of this paper was to determine the effectiveness of neodymium YAG laser (Nd-YAG laser on performing the posterior capsulotomy in 150 patients (eyes operated on of senile or presenile cataract at the Center of Serial Ocular Microsurgery (CSOM of "Ramón Pando Ferrer" Ophthalmological Teaching Hospital from February to December 1999. Age, sex, race, implantation or not of the intraocular lens (IOL, type of opacity of the posterior capsule, visual acuity with pre- and posttreatment correction (Avcc, complications found, behavior of the intraocular pressure (IOP, as well as the energy used to carry out such procedure, were analyzed. The Chi square contingency tables were used to this end. As a result of this research, it was found that the laser is highly effective for improving visual acuity in patients

  5. Effects of Q-switched and long-pulsed 1064 nm Nd:YAG laser on enlarged facial pores.

    Science.gov (United States)

    Lee, Chang Nam; Kim, You Jeong; Lee, Hyun Seung; Kim, Hei Sung

    2009-12-01

    'Enlarged facial pore' is a subjective term, which is not clearly defined but often complained by many. A diverse range of treatments are used though evidence of efficacy remains largely anecdotal. We report a series of nine patients who underwent a split face trial with Q-switched 1064 nm Nd:YAG and long-pulsed 1064 nm Nd:YAG laser to treat enlarged facial pores.

  6. Combined pulsed dye laser and fiberoptic Nd-YAG laser for the treatment of hypertrophic port wine stain.

    Science.gov (United States)

    Radmanesh, Mohammed; Radmanesh, Ramin

    2017-10-01

    The hypertrophic Port Wine Stain (PWS) is only partially and superficially treated with the Pulsed dye laser (PDL) because of its limited depth of penetration. We used combined PDL and fiberoptic 1444-nm Nd-YAG laser to treat a case with hypertrophic PWS. After tumescent anesthesia, few holes were made by a 16-gauge needle on different sides of the lesion. The fiberoptic tip of 1444-nm Nd-YAG laser was inserted within the holes and was pushed forward while triggering. In a fan pattern and by a back and forth movement, the subcutaneous and deep dermal areas were coagulated. The skin and outer mucosal surfaces were then treated by PDL. The fiberoptic system used was Accusculpt 1444-nm Nd-YAG laser (Lutronic lasers, South Korea), and the PDL used was 585 nm Nlite system (Chromogenex UK). The parameters used for PDL were fluence = 9 Joules/cm 2 and the spot size was 5 mm. The parameters used for fiberoptic 1444-nm Nd-YAG laser were: Pulse rate = 30 Hz, pulse energy = 300 mJ, power = 6 W, and the total energy = 4000 J for the whole face and mucosa. Little sign of regression and moderate purpura were detected immediately after combined fiberoptic Nd-YAG and PDL therapy. The lesion gradually regressed within 4 months with satisfactory color and volume change. Combined fiberoptic Nd-YAG laser and PDL can be used for the treatment of deeper and superficial layers of hypertrophic PWS.

  7. Neodymium: YAG laser damage threshold. A comparison of injection-molded and lathe-cut polymethylmethacrylate intraocular lenses.

    Science.gov (United States)

    Wilson, S E; Brubaker, R F

    1987-01-01

    The possibility that injection-molded intraocular lenses (IOLs) with imperfections called iridescent clefts could have a decreased threshold to neodymium: YAG (Nd:YAG) laser-induced damage was investigated. Thresholds for Nd:YAG laser-induced damage were determined for injection-molded and lathe-cut polymethylmethacrylate lenses. When aimed at a membrane in contact with a posterior convex surface, the average thresholds were 0.96 +/- 0.18 mJ (Standard deviation [SD]) and 1.80 +/- 0.55 mJ, respectively. The difference was significant at P = 0.001. When injection-molding polymethylmethacrylate was used to make lathe-cut IOLs, very few iridescent clefts were present, and the threshold to Nd:YAG laser-induced damage was 0.94 +/- 0.25 mJ. Iridescent clefts are therefore produced during the injection-molding process but they do not lower the threshold to Nd:YAG laser-induced damage. Rather, the reduced threshold in injection-molded lenses is most probably a result of the polymethylmethacrylate used in their manufacture. Clinically, iridescent clefts in a lens suggest that it has been manufactured by an injection-molding process and that Nd:YAG laser posterior capsulotomy must be performed at the lowest possible energy level to avoid damage.

  8. Intraoperative localized urticarial reaction during Q-switched Nd:YAG laser tattoo removal.

    Science.gov (United States)

    Wilken, Reason; Ho, Derek; Petukhova, Tatyana; Jagdeo, Jared

    2015-03-01

    Q-switched lasers, such as the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser, are the gold standard for tattoo removal. Allergy to tattoo pigment is well-documented, but adverse allergic reactions during or shortly after laser tattoo removal are rare with few reports in the medical literature. Here we describe an intraoperative, localized urticarial reaction that developed during treatment of a tattoo using a 1064-nm Nd:YAG laser. As laser tattoo removal becomes increasingly popular amongst our patients, it is important for dermatologists to be aware of urticarial allergic reactions as well as their management. We outline our recommendations for medical management of this condition and hope that these guidelines will facilitate patient care by dermatologists who encounter this immune skin reaction to laser tattoo removal

  9. Design of a high-power, high-brightness Nd:YAG solar laser.

    Science.gov (United States)

    Liang, Dawei; Almeida, Joana; Garcia, Dário

    2014-03-20

    A simple high-power, high-brightness Nd:YAG solar laser pumping approach is presented in this paper. The incoming solar radiation is both collected and concentrated by four Fresnel lenses and redirected toward a Nd:YAG laser head by four plane-folding mirrors. A fused-silica secondary concentrator is used to compress the highly concentrated solar radiation to a laser rod. Optimum pumping conditions and laser resonator parameters are found through ZEMAX and LASCAD numerical analysis. Solar laser power of 96 W is numerically calculated, corresponding to the collection efficiency of 24  W/m². A record-high solar laser beam brightness figure of merit of 9.6 W is numerically achieved.

  10. Single-Frequency Nd:YAG Ring Lasers with Corner Cube Prism

    Science.gov (United States)

    Wu, Ke-Ying; Yang, Su-Hui; Zhao, Chang-Ming; Wei, Guang-Hui

    2000-10-01

    We put forward another form of the non-planar ring lasers, in which the corner cube prism is the key element and the Nd:YAG crystal is used as a Porro prism to enclose the ring resonator. The phase shift due to the total internal reflections of the three differently orientated reflection planes of the corner cube prism, Faraday rotation in the Nd:YAG crystal placed in a magnetic field and the different output coupling in S and P polarization form an optical diode and enforce the single-frequency generating power. A round trip analysis of the polarization properties of the resonator is made by the evaluation of Jones matrix.

  11. 11-GHz waveguide Nd:YAG laser CW mode-locked with single-layer graphene.

    Science.gov (United States)

    Okhrimchuk, Andrey G; Obraztsov, Petr A

    2015-06-08

    We report stable, passive, continuous-wave (CW) mode-locking of a compact diode-pumped waveguide Nd:YAG laser with a single-layer graphene saturable absorber. The depressed cladding waveguide in the Nd:YAG crystal is fabricated with an ultrafast laser inscription method. The saturable absorber is formed by direct deposition of CVD single-layer graphene on the output coupler. The few millimeter-long cavity provides generation of 16-ps pulses with repetition rates in the GHz range (up to 11.3 GHz) and 12 mW average power. Stable CW mode-locking operation is achieved by controlling the group delay dispersion in the laser cavity with a Gires-Tournois interferometer.

  12. Black phosphorus saturable absorber for Q-switched Er:YAG laser at 1645 nm

    Science.gov (United States)

    Guo, Lei; Li, Tao; Zhang, Shuaiyi; Wang, Mingjian; Yang, Kejian; Fan, Mingqi; Zhao, Shengzhi; Li, Ming

    2018-03-01

    A Q-switched Er:YAG solid-state laser at 1645 nm based on black phosphorus (BP) saturable absorbers (SAs) was demonstrated firstly to our knowledge. The BP-SA was fabricated by drop-casting BP nanoplatelets dispersion on a YAG substrate and corresponding saturable absorption properties were characterized at 1.6 μm. By employing as-prepared BP-SAs, stable Q-switched laser operations were achieved with a pulse width of 2.8 μs and a repetition rate of 34 kHz, corresponding to the average output power of 0.33 W. The results verify that BP-SAs have great potential for pulsed 1.6 μm lasers.

  13. Development of surgical CW Nd:YAG laser with optical fiber delivery system

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Kim, Jeong Mook; Jung, Chin Mann; Kim, Kwang Suk; Kim, Min Suk; Cho, Jae Wan; Kim, Duk Hyun

    1992-06-01

    We developed a surgical CW Nd:YAG laser with optical fiber delivery system. Several commercial models have been investigated in design and performance. We improved its quality to the level of commercial Nd:YAG laser by an endurance test for each parts of laser system. The maximum power of our surgical laser was 150 W and the laser pulse width could be controlled to 99 sec continuously by 0.1 sec. Many optical parts were localized and lowered much in cost. Only few parts were imported and almost 90% in cost were localized. Also, to find out the maintenance problem of this surgical laser, it was applicated to the production line of our joint company. (Author)

  14. Diode-pumped Kerr-lens mode-locked femtosecond Yb:YAG ceramic laser

    Science.gov (United States)

    Zi-Ye, Gao; Jiang-Feng, Zhu; Ke, Wang; Jun-Li, Wang; Zhao-Hua, Wang; Zhi-Yi, Wei

    2016-02-01

    We experimentally demonstrated a diode-pumped Kerr-lens mode-locked femtosecond laser based on an Yb:YAG ceramic. Stable laser pulses with 97-fs duration, 2.8-nJ pulse energy, and 320-mW average power were obtained. The femtosecond oscillator operated at a central wavelength of 1049 nm and a repetition rate of 115 MHz. To the best of our knowledge, this is the first demonstration of a Kerr-lens mode-locked operation in a diode-pumped Yb:YAG ceramic laser with sub-100 fs pulse duration. Project supported by the National Major Scientific Instrument Development Project of China (Grant No. 2012YQ120047), the National Natural Science Foundation of China (Grant No. 61205130), and the Fundamental Research Funds for the Central Universities, China (Grant No. JB140502).

  15. Synthesis of alumina/YAG 20 vol% composite by co-precipitation

    Directory of Open Access Journals (Sweden)

    Radosław Lach

    2011-12-01

    Full Text Available Co-precipitation of alumina/YAG precursor from aluminum and yttrium nitrate solution with ammonium carbonate results in dawsonite. Its crystallographic parameters differ from the compound precipitated with no yttrium additive. It suggests that yttrium ions become incorporated into the dawsonite structure. The DSC/TG and X-ray diffraction measurements show decomposition of dawsonite at elevated temperatures resulting in γ-Al2O3 and then δ- and θ-alumina modifications. Full transformation to α-Al2O3 and YAG occurs at temperatures higher than 1230°C. Starting powder for the sintering experiments was prepared using the coprecipitated precursor calcined at 600°C. Seeding of such powder with 5 wt.% α-Al2O3 results in material of 98% density at 1500°C. Much lower densification show compacts of unseeded powder.

  16. Changes in nail keratin observed by Raman spectroscopy after Nd:YAG laser treatment.

    Science.gov (United States)

    Shin, Min Kyung; Kim, Tae In; Kim, Wan Sun; Park, Hun-Kuk; Kim, Kyung Sook

    2017-04-01

    Lasers and photodynamic therapy have been considered a convergence treatment for onychomycosis, which is a fungal infection on the nail bed and nail plate. Laser therapies have shown satisfactory results without significant complications for onychomycosis; however, the mechanism of clearing remains unknown. In this work, we investigated changes in the chemical structure of nail keratin induced by Nd:YAG laser using Raman spectroscopy. Toe nails with onychomycosis were treated with 1064 nm Nd:YAG laser. After laser treatment, the disulfide band (490-590 cm -1 ) of nail keratin was rarely observed or was reduced in intensity. The amide I band (1500-1700 cm -1 ) also showed changes induced by the laser. The α-helical (1652 cm -1 ) structures dominated the β-sheet (1673 cm -1 ) in nontreated nail, but the opposite phenomenon was observed after laser treatment. © 2016 Wiley Periodicals, Inc.

  17. Femtosecond laser inscribed cladding waveguides in Nd:YAG ceramics: fabrication, fluorescence imaging and laser performance.

    Science.gov (United States)

    Liu, Hongliang; Jia, Yuechen; Vázquez de Aldana, Javier Rodríguez; Jaque, Daniel; Chen, Feng

    2012-08-13

    We report on the fabrication of depressed cladding waveguide lasers in Nd:YAG (neodymium doped yttrium aluminum garnet, Nd:Y3Al5O12) ceramics microstructured by femtosecond laser pulses. Full control over the confined light spatial distribution is demonstrated by the fabrication of high contrast waveguides with hexagonal, circular and trapezoidal configurations. The confocal fluorescence measurements of the waveguides reveal that the original luminescence features of Nd3+ ions are well-preserved in the waveguide regions. Under optical pump at 808 nm, cladding waveguides showed continuous wave efficient laser oscillation. The maximum output power obtained at 1064.5 nm is ~181 mW with a slope efficiency as high as 44%, which suggests that the fabricated Nd:YAG ceramic waveguides are promising candidates for efficient integrated laser sources.

  18. YAG laser in the treatment of hemorrhoids: a report of 700 cases

    Science.gov (United States)

    Liu, Jian-xun; Zhang, Xinrong

    1993-03-01

    The results of treating hemorrhoids in 700 cases with a YAG laser knife is reported. Since 1988, the author introduced the YAG laser into the treatment of various kinds of hemorrhoids. The satisfactory results were achieved with 100% cure rate. Some related problems also are discussed in this paper. Hemorrhoid is a kind of common disease. It usually appears in the superior or inferior rectal venous plexus covered with mucosa. The hemorrhoids are divided into internal, external, and mixed types according to their location and origination. The internal hemorrhoid is superior to the dentate line and caused by varicosity of superior rectal venous plexus covered with mucosa, the most common presentation is a bleeding and prolapse mass out of the anus. The external hemorrhoid arises from varicosity of inferior rectal venous plexus, the most important clinical finding is a painful mass covered with skin of the anal canal. The characteristics of mixed type are the combination of the two types as mentioned above.

  19. Er:YAG laser pulse for small-dose splashback-free microjet transdermal drug delivery.

    Science.gov (United States)

    Park, Mi-ae; Jang, Hun-jae; Sirotkin, Fedir V; Yoh, Jack J

    2012-09-15

    The microjet injector system accelerates drugs and delivers them without a needle, which is shown to overcome the weaknesses of existing jet injectors. A significant increase in the delivered dose of drugs is reported with multiple pulses of laser beam at lower laser energy than was previously used in a Nd:YAG system. The new injection scheme uses the beam wavelength best absorbable by water at a longer pulse mode for elongated microjet penetration into a skin target. A 2.9 μm Er:YAG laser at 250 μs pulse duration is used for fluorescent staining of guinea pig skin and for injection controllability study. Hydrodynamic theory confirms the nozzle exit jet velocity obtained by the present microjet system.

  20. Experimental analysis of Nd-YAG laser cutting of sheet materials - A review

    Science.gov (United States)

    Sharma, Amit; Yadava, Vinod

    2018-01-01

    Cutting of sheet material is considered as an important process due to its relevance among products of everyday life such as aircrafts, ships, cars, furniture etc. Among various sheet cutting processes (ASCPs), laser beam cutting is one of the most capable ASCP to create complex geometries with stringent design requirements in difficult-to-cut sheet materials. Based on the recent research work in the area of sheet cutting, it is found that the Nd-YAG laser is used for cutting of sheet material in general and reflective sheet material in particular. This paper reviews the experimental analysis of Nd-YAG laser cutting process, carried out to study the influence of laser cutting parameters on the process performance index. The significance of experimental modeling and different optimization approaches employed by various researchers has also been discussed in this study.

  1. Development of remote bore tools for pipe welding/cutting by YAG laser

    International Nuclear Information System (INIS)

    Oka, Kiyoshi; Nakahira, Masataka; Kakudate, Satoshi; Tada, Eisuke; Obara, Kenjiro; Taguchi, Kou; Nakamori, Naokazu

    1996-07-01

    In D-T burning reactors such as International Thermonuclear Experimental Reactor (ITER), an internal access welding/cutting of blanket cooling pipe with bend sections is inevitably required because of spatial constraint due to nuclear shield and available port opening space. For this purpose, an internal access pipe welding/cutting using YAG laser beam is being developed according to the agreement of the ITER R and D task (T44). A design concept of welding/cutting processing head with a flexible optical fiber has been developed and the basic feasibility studies on welding, cutting and rewelding are performed using stainless steel plate (SS316L). In this report, the details of a welding/cutting head with a flexible optical fiber for YAG laser are described, together with the basic experiment results relating to the welding/cutting and rewelding. (author)

  2. Freeze frame analysis on high speed cinematography of Nd/YAG laser explosions in ocular tissues.

    Science.gov (United States)

    Vernon, S A; Cheng, H

    1986-01-01

    High speed colour cinematography at 400 frames per second was used to photograph both single and train burst Nd/YAG laser applications in ox eyes at threshold energy levels. Measurements of the extent and speed of particle scatter and tissue distortion from the acoustic transient were made from a sequential freeze frame analysis of the films. Particles were observed to travel over 8 mm from the site of Nd/YAG application 20 milliseconds after a single pulse at initial speeds in excess of 20 km/h. The use of train bursts of pulses was seen to increase the number of particles scattered and project the wavefront of particles further from the point of laser application. Images PMID:3754458

  3. Injection seeded, diode pumped regenerative ring Nd:YAG amplifier for spaceborne laser ranging technology development

    Science.gov (United States)

    Coyle, D. Barry; Kay, Richard B.; Degnan, John J.; Krebs, Danny J.; Seery, Bernard D.

    1992-01-01

    A small, all solid state, regenerative ring amplifier designed as a prototype for space application is discussed. Novel features include dual side pumping of the Nd:YAG crystal and a triangular ring cavity design which minimizes the number of optical components and losses. The amplifier is relatively small (3 ns round trip time) even though standard optical elements are employed. The ring regeneratively amplifies a 100 ps single pulse by approximately 10(exp 5) at a repetition rate of 10 to 100 Hz. The amplifier is designed to be injection seeded with a pulsed, 100 ps laser diode at 1.06 microns, but another Nd:YAG laser system supplying higher pulse energies was employed for laboratory experiment. This system is a prototype laser oscillator for the Geoscience Laser Ranging System (GLRS) platform. Results on measurements of beam quality, astigmatism, and gain are given.

  4. Inner structure detection by optical tomography technology based on feedback of microchip Nd:YAG lasers.

    Science.gov (United States)

    Xu, Chunxin; Zhang, Shulian; Tan, Yidong; Zhao, Shijie

    2013-05-20

    We describe a new optical tomography technology based on feedback of microchip Nd:YAG lasers. In the case of feedback light frequency-shifted, light can be magnified by a fact of 10(6) in the Nd:YAG microchip lasers, which makes it possible to realize optical tomography with a greater depth than current optical tomography. The results of the measuring and imaging of kinds of samples are presented, which demonstrate the feasibility and potential of this approach in the inner structure detection. The system has a lateral resolution of ~1 μm, a vertical resolution of 15 μm and a longitudinal scanning range of over 10mm.

  5. UNS S32750 super duplex steel welding using pulsed Nd:YAG laser

    International Nuclear Information System (INIS)

    Francini, O.D.; Andrade, G.G.; Clemente, M.S.; Gallego, J.; Ventrella, V.A.

    2016-01-01

    Laser is a flexible and powerful tool with many relevant applications in industry, mainly in the welding area. Lasers today provide the welding industry technical solutions to many problems. This work studied the weld metal obtained by pulsed laser welding of Nd: YAG super duplex stainless steel UNS S32750 employed in the oil and natural gas, analyzing the influence of high cooling rate, due to the laser process, the swing phase ferrite / austenite. Were performed weld beads in butt joint with different repetition rates. The different microstructures were obtained by optical microscopy and scanning electron microscopy. The results showed that the effect of varying the welding energy of Nd: YAG laser on the volume fractions of the phases ferrite/austenite in the weld metal was its ferritization and low austenite amount on the grain boundary. (author)

  6. Endoscopic palliation of esophageal and cardial cancer: Nd:YAG laser and prosthesis

    Science.gov (United States)

    Norberto, Lorenzo; Ranzato, Riccardo; Marino, Saverio; Angriman, Imerio; Vella, Vincenzo; Donadi, Michele; D'Amico, D. F.

    1997-12-01

    From November 1, 1992 to January 31, 1997, 227 patients with inoperable esophageal and cardial carcinomas were treated with Nd:YAG laser therapy and prosthesis intubation. The retrograde technique was used in most cases. The tumor involved in 75 pts the Cardia, in 65 the middle thoracic esophagus, in 47 pts the lower thoracic esophagus, in 23 in the upper thoracic esophagus and in 17 in the cervical esophagus. The indications for palliative Nd:YAG laser and prosthesis intubation were a locally advanced or metastatic tumor in 146 pts (64.4%) and poor surgical risk in 81 pts (35.6%). The quality of palliation was evaluated according to the ability to swallow. The mean survival rate of the patients during the follow up was 22 weeks for the laser therapy and 16 weeks for the prosthesis intubation.

  7. Freeze frame analysis on high speed cinematography of Nd/YAG laser explosions in ocular tissues.

    Science.gov (United States)

    Vernon, S A; Cheng, H

    1986-05-01

    High speed colour cinematography at 400 frames per second was used to photograph both single and train burst Nd/YAG laser applications in ox eyes at threshold energy levels. Measurements of the extent and speed of particle scatter and tissue distortion from the acoustic transient were made from a sequential freeze frame analysis of the films. Particles were observed to travel over 8 mm from the site of Nd/YAG application 20 milliseconds after a single pulse at initial speeds in excess of 20 km/h. The use of train bursts of pulses was seen to increase the number of particles scattered and project the wavefront of particles further from the point of laser application.

  8. Scintillation properties of transparent ceramic and single crystalline Nd:YAG scintillators

    International Nuclear Information System (INIS)

    Yanagida, Takayuki; Kamada, Kei; Fujimoto, Yutaka; Yokota, Yuui; Yoshikawa, Akira; Yagi, Hideki; Yanagitani, Takagimi

    2011-01-01

    Nd 0.1, 1.1, 2, 4, and 6 mol% doped YAG transparent ceramics are manufactured by the sintering method and their scintillation properties are compared with those of single crystalline Nd 1 mol% doped YAG grown by the micro-pulling down method. They show ∼80% transmittance at wavelengths longer than 300 nm and strong emission lines due to Nd 3+ 4f-4f emission in their radio-luminescence spectra. Among them, the single crystalline sample shows the highest light yield of 11,000 ph/MeV under γ-ray excitation and the second highest one is from Nd 1.1 mol% doped transparent ceramic, which shows 6000 ph/MeV. In these scintillators, dominant decay time constant is around 2-3 μs due to Nd 3+ 4f-4f transitions.

  9. Scintillation properties of transparent ceramic and single crystalline Nd:YAG scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Takayuki, E-mail: t_yanagi@tagen.tohoku.ac.j [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Kamada, Kei; Fujimoto, Yutaka; Yokota, Yuui [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); Yoshikawa, Akira [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, 2-1-1 Katahira, Aoba-ku, Sendai 980-8577 (Japan); New Industry Creation Hatchery Center (NICHe), Tohoku University, 6-6-10 Aoba, Aramaki, Aoba-ku, Sendai 980-8579 (Japan); Yagi, Hideki; Yanagitani, Takagimi [Konoshima Chemical Co., Ltd., 80 Kouda, Takuma, Mitoyo-gun, Kagawa 769-1103 (Japan)

    2011-03-01

    Nd 0.1, 1.1, 2, 4, and 6 mol% doped YAG transparent ceramics are manufactured by the sintering method and their scintillation properties are compared with those of single crystalline Nd 1 mol% doped YAG grown by the micro-pulling down method. They show {approx}80% transmittance at wavelengths longer than 300 nm and strong emission lines due to Nd{sup 3+} 4f-4f emission in their radio-luminescence spectra. Among them, the single crystalline sample shows the highest light yield of 11,000 ph/MeV under {gamma}-ray excitation and the second highest one is from Nd 1.1 mol% doped transparent ceramic, which shows 6000 ph/MeV. In these scintillators, dominant decay time constant is around 2-3 {mu}s due to Nd{sup 3+} 4f-4f transitions.

  10. Neutron diffraction studies of Ho1-xYxNi2B2C compounds

    DEFF Research Database (Denmark)

    Chang, L.J.; Tomy, C.V.; Paul, D.M.K.

    1996-01-01

    Neutron diffraction measurements have been carried out to investigate the nature of magnetic ordering in Ho(1-x)Y(x)Ni(2)B(2)C (x = 0, 0.1 and 0.2) compounds. HoNi(2)B(2)C shows a complex type of magnetic ordering below the superconducting transition, with a commensurate antiferromagnetic ordering...

  11. Ozone decomposition in water studied by pulse radiolysis. 2. OH and HO4 as chain intermediates

    International Nuclear Information System (INIS)

    Staehelin, J.; Buehler, R.E.; Hoigne, J.

    1984-01-01

    Ozone decomposition in pure water involves a chain mechanism, initiated by the reaction OH - +O 3 and propogated by O 2 - and OH. In the present studies this chain is initiated by pulse radiolysis of aqueous solutions of ozone. The chain propogation steps were studied in two parts. By computer simulation of the rate curves, it is shown that from OH + O 3 and intermediate HO 4 must be formed, most likely a charge-transfer complex (HO.O 3 ), which eventually decays into HO 2 . The derived rate constants for the formation of the various species are included. The spectrum of HO 4 is derived. It is similar to the one of ozone, but the absorption coefficients are about 50% larger. In the presence of high ozone concentration, the dominant chain termination reactions are HO 4 + HO 4 and HO 4 + HO 3 . The effect on chain length, dose, overall rate, and pH and of added scavengers is described. The implications for the natural ozone decay mechanism are discussed

  12. HO-1-mediated macroautophagy: a mechanism for unregulated iron deposition in aging and degenerating neural tissues.

    Science.gov (United States)

    Zukor, Hillel; Song, Wei; Liberman, Adrienne; Mui, Jeannie; Vali, Hojatollah; Fillebeen, Carine; Pantopoulos, Kostas; Wu, Ting-Di; Guerquin-Kern, Jean-Luc; Schipper, Hyman M

    2009-05-01

    Oxidative stress, deposition of non-transferrin iron, and mitochondrial insufficiency occur in the brains of patients with Alzheimer disease (AD) and Parkinson disease (PD). We previously demonstrated that heme oxygenase-1 (HO-1) is up-regulated in AD and PD brain and promotes the accumulation of non-transferrin iron in astroglial mitochondria. Herein, dynamic secondary ion mass spectrometry (SIMS) and other techniques were employed to ascertain (i) the impact of HO-1 over-expression on astroglial mitochondrial morphology in vitro, (ii) the topography of aberrant iron sequestration in astrocytes over-expressing HO-1, and (iii) the role of iron regulatory proteins (IRP) in HO-1-mediated iron deposition. Astroglial hHO-1 over-expression induced cytoplasmic vacuolation, mitochondrial membrane damage, and macroautophagy. HO-1 promoted trapping of redox-active iron and sulfur within many cytopathological profiles without impacting ferroportin, transferrin receptor, ferritin, and IRP2 protein levels or IRP1 activity. Thus, HO-1 activity promotes mitochondrial macroautophagy and sequestration of redox-active iron in astroglia independently of classical iron mobilization pathways. Glial HO-1 may be a rational therapeutic target in AD, PD, and other human CNS conditions characterized by the unregulated deposition of brain iron.

  13. Paracrine action of HO-1-modified mesenchymal stem cells mediates cardiac protection and functional improvement.

    Science.gov (United States)

    Zeng, Bin; Ren, Xiaofeng; Lin, Guosheng; Zhu, Chengang; Chen, Honglei; Yin, Jiechao; Jiang, Hong; Yang, Bo; Ding, Danhua

    2008-10-01

    The aim has been to determine whether the supernatants of mesenchymal stem cells (MSCs) transfected with adenovirus carrying human heme oxygenase-1 (hHO-1) gene protect cardiomyocytes from ischemic injury. We have found that hHO-1 infected MSCs (hHO-1-MSCs) increased expression of hHO-1 protein. Apoptosis of cultured hHO-1-MSCs exposed to hypoxia was suppressed. Several cytokines, including HGF, bFGF, TGF-beta, VEGF and IL-1beta, were produced by hHO-1-MSCs, some being significantly enhanced under hypoxia stimulation. Meanwhile, those cytokines reduced caspase-3 level and activity in cultured adult rat ventricular cardiomyocytes (ARVCs) exposed to hypoxia. Supernatants obtained from hHO-1-MSCs improved left ventricular function, limited myocardial infarct size, increased microvessel density, and inhibited apoptosis of cardiomyocytes in rat myocardial infarction. It can be concluded hHO-1-modified MSCs prevent myocardial cell injury via secretion of paracrine-acting mediators.

  14. Q-switched Ho:YLF laser pumped by a Tm:GdVO4 laser.

    CSIR Research Space (South Africa)

    Esser, MJD

    2009-06-01

    Full Text Available The authors have, through careful analysis of spectroscopic data, designed and demonstrated a diode-end-pumped, quasicontinuous wave Tm:GdVO4 laser operating at 1892 nm in order to pump a Q-switched Ho:YLF laser. The Ho:YLF maximum output energy...

  15. Experimental Investigation of Phase Equilibria in the Ho-Ti-Si Ternary System at 973 K (700 °C)

    Science.gov (United States)

    Han, Feng; Zhan, Yongzhong

    2018-02-01

    Phase equilibrium relations of the Ho-Ti-Si ternary system at 973 K (700 °C) were experimentally researched by means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive spectrometer (EDS). The isothermal section of the system at 973 K (700 °C) consists of 14 three-phase regions, 27 two-phase regions, and 14 single-phase regions. The phases Ti5Si3, Ti5Si4, TiSi, TiSi2, Ho5Si3, Ho5Si4, HoSi, αHoSi2-b, and βHoSi2-a are proved to exist at 973 K (700 °C). Previously reported HoTiSi and Ho2Ti3Si4 ternary compounds were confirmed to exist at this temperature. The solubility of Ho in the intermediate phases (i.e., TiSi2, TiSi, Ti5Si4, and Ti5Si3) at the Ti-Si side is extremely small. The maximum solubilities of Ti in HoSi2-b, Ho5Si4, and Ho5Si3 are confirmed to be 8.0, 7.2, and 6.0 at. pct, respectively.

  16. Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of Ho-166 Microspheres in Liver Radioembolization

    NARCIS (Netherlands)

    Seevinck, Peter R.; van de Maat, Gerrit H.; de Wit, Tim C.; Vente, Maarten A. D.; Nijsen, Johannes F. W.; Bakker, Chris J. G.

    2012-01-01

    Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional Ho-166 activity distribution to estimate radiation-absorbed dose distributions in Ho-166-loaded poly (L-lactic acid) microsphere (Ho-166-PLLA-MS) liver radioembolization.

  17. His Excellency Professor Dr Che-Ho Wei, Chairman, National Science Council Executive Yuan, Republic of China

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    Photo 01: Professor Dr. Che-Ho Wei signing the Guest Book with CERN Director-General, L. Maiani. Photo 02: Professor Dr. Che-Ho Wei. Photo 03::Professor Dr. Che-Ho Wei shaking hands with CERN Director-General, L. Maiani.

  18. A 526 W Diode-Pumped Nd:YAG Ceramic Slab Laser

    International Nuclear Information System (INIS)

    Chen Yan-Zhong; Bo Yong; Xu Jian; Xu Yi-Ting; Xu Jia-Lin; Guo Ya-Ding; Yang Feng-Tu; Peng Qin-Jun; Cui Da-Fu; Xu Zu-Yan; Liu Wen-Bin; Jiang Ben-Xue; Kou Hua-Min; Pan Yu-Bai; Jiang Dong-Liang

    2011-01-01

    A diode-side-pumped Nd:YAG ceramic slab laser with a high power output is presented. An average power of 526 W is achieved at 1064 nm with a repetition rate of 120 Hz and a pulse width of 180 μs from a 93mm × 52mm × 8 mm ceramic slab at a pump power of 1928 W, corresponding to an optical-to-optical efficiency of 27.3%. (fundamental areas of phenomenology(including applications))

  19. CdS thin films prepared by continuous wave Nd:YAG laser

    Science.gov (United States)

    Wang, H.; Tenpas, Eric W.; Vuong, Khanh D.; Williams, James A.; Schuesselbauer, E.; Bernstein, R.; Fagan, J. G.; Wang, Xing W.

    1995-08-01

    We report new results on continuous wave Nd:YAG laser deposition of cadmium sulfide thin films. Substrates were soda-lime silicate glass, silica glass, silicon, and copper coated formvar sheets. As deposited films were mixtures of cubic and hexagonal phases, with two different grain sizes. As revealed by SEM micrographs, films had smooth surface morphology. As revealed by TEM analysis, grain sizes were extremely small.

  20. BLEPHAROPLASTY AND PERIOCULAR SKIN RESURFACING WITH NEW GENERATION ER:YAG LASER

    Directory of Open Access Journals (Sweden)

    Brigita Drnovšek-Olup

    2002-12-01

    Full Text Available Background. In this study, a new type of Er:YAG laser, emitting irradiation with variable pulse duration, has been used for blepharoplasty and skin resurfacing in periocular region.More than 40 patients have been treated with second generation Er:YAG laser (Fotona Fidelis for blepharoplasty and skin resurfacing. A focused laser beam (diameter 0.4 mm with very short pulse width (100 µs, that is significantly below the thermal relaxation time of skin, leads to a precise cut with no observable thermal effect on surrounding tissue. The depth of the cut is approximately 1–2 mm, precision comparable to a surgical scalpel. The high repetition rate of consecutive laser pulses (50 Hz at 120 mJ energy accounts for accumulation of thermal load in tissue, and thus leads to complete hemostasis of the cut tissue. Due to improved cutting abilities of the Er:YAG laser, excision of orbital fat is also performed with one pass of the laser beam. By changing the laser parameters to short pulses (300 µs, energy 500 mJ, spot diameter 5 mm and repetition rate 12–15 Hz, skin resurfacing was performed. No special pretreatment therapy was used. Anesthesia: 2% Xylocain inj. subcutaneously. Non adhesive dressing for 24 hours was applied after surgery.Epithelisation was complete after ten days. Redness persists up to 5 weeks. Discomfort of patients was mild. Cosmetic results are satisfying.Conclusions. New generation of Er:YAG laser offers a possibility to cut and coagulate the tissue simultaneously, and by changing the parameters to ablate the tissue with heating influence on skin collagen.

  1. Investigation of micro-plasma in physiological saline produced by a high-power YAG laser

    International Nuclear Information System (INIS)

    Lu Jian; Ni Xiaowu; He Anzhi

    1994-01-01

    Micro-plasma and shock waves in the physiological saline produced by a Q-switched pulse YAG laser with nearby optical breakdown threshold energy are investigated by using optical shadowing exploring method, and a series of optical shadow graphs of micro-plasma and shock waves versus the incident laser energy and the delay time are obtained. Influence of mechanical action of shock waves for the high-power pulse laser on the ophthalmic treatment is discussed

  2. The therapeutic effects of the endolaryngeal use of neodymium: YAG-laser

    International Nuclear Information System (INIS)

    Karduck, A.; Blank, M.; Essen Univ.

    1979-01-01

    A short review of experiences in animal usage is made, and the first clinical experiences with the endolaryngeal application of the Neodymium: YAG laser MediLas in the treatment of benign vocal cord lesions are reported. The initial results are favourable, but final judgement of this microsurgical technique must be based upon a larger number of patients and a longer for follow-up. (orig.) 891 AJ/orig. 892 CKA [de

  3. Interpreting coherent anti-Stokes Raman spectra measured with multimode Nd:YAG pump lasers

    International Nuclear Information System (INIS)

    Farrow, R.L.; Rahn, L.A.

    1985-01-01

    We report comparisons of coherent anti-Stokes Raman spectroscopy (CARS) measurements using single-axial-and multiaxial-mode Nd:YAG lasers. Our results demonstrate the validity of a recently proposed convolution expression for unresolved CARS spectra. The results also support the use of a relative delay of several coherence lengths between pump-beam paths for reducing the effects of pump-field statistics on the CARS spectral profile

  4. A pilot study of treatment of striae distensae with variable square pulse Erbium: YAG laser resurfacing.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Meeprathom, Walailak; Manuskiatti, Woraphong

    2017-12-01

    Striae distensae (SD) are a frequent skin condition for which treatment remains a challenge. Various laser treatments have been employed to remove the epidermis and cause dermal wound and heating with subsequent dermal collagen remodeling. To determine the efficacy and safety of a variable square pulse Erbium: YAG (VSP Er:YAG) laser for the treatment of striae in skin phototypes III-IV. Twenty-one women with SD were treated monthly for 2 months with VSP Er:YAG laser resurfacing using a 7-mm spot size. One side of their striae was randomly treated with one pass of 400 mJ in short pulse (SP) mode with 50% overlapping and one pass of 2.2 J/cm 2 in smooth (SM) mode with nonoverlapping. The other side of their striae was treated with two passes of 400 mJ in SP mode with 50% overlapping. Objective and subjective assessments were obtained at baseline and 1-, 3-, and 6-month after treatment. In both SP&SM and SP only group, volume of SD measured by Visioscan VC98 reduced significantly at 6-month follow-up visit (P=.017 and P=.034, respectively). There were no statistically significant differences in skin roughness (SER), skin smoothness (SESM), and surface measured by Visioscan VC98. Transient postinflammatory hyperpigmentation (PIH) is the common side effect found in patients with darker skin tone even in nonsun exposure areas and can last as long as 6 months. VSP Er:YAG laser resurfacing is a promising treatment option for SD. Lower fluence should be used in patients with darker skin phototype to avoid the risk of PIH. In addition, pre- and post-treatment with topical preparations for PIH prevention may be needed. © 2017 Wiley Periodicals, Inc.

  5. High-efficiency diode-pumped femtosecond Yb:YAG ceramic laser

    DEFF Research Database (Denmark)

    Zhou, Binbin; Wei, Z.Y.; Zou, Y.W.

    2010-01-01

    A highly efficient diode-end-pumped femtosecond Yb:yttrium aluminum garnet (YAG) ceramic laser was demonstrated. Pumped by a 968 nm fiber-coupled diode laser, 1.9 W mode-locked output power at a repetition rate of 64.27 MHz was obtained with 3.5 W absorbed pump power, corresponding to a slope...... efficiency of 76%. Our measurement showed that the pulse duration was 418 fs with the central wavelength of 1048 nm....

  6. Mode locking of Yb:GdYAG ceramic lasers with an isotropic cavity

    International Nuclear Information System (INIS)

    Xu, C W; Tang, D Y; Zhu, H Y; Zhang, J

    2013-01-01

    We report on the passive mode locking of a diode pumped Yb:GdYAG ceramic laser with a near isotropic cavity. It is found that the laser could simultaneously mode lock in the two orthogonal principal polarization directions of the cavity, and the mode locked pulses of the two polarizations have identical features and are temporally perfectly synchronized. However, their pulse energy varies out-of-phase periodically, manifesting the antiphase dynamics of mode locked lasers. (letter)

  7. Diode and Nd:YAG laser in a case of refractory acne keloidalis nuchae

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Chittoria

    2015-03-01

    Full Text Available Acne keloidalis nuchae (AKN is a disease of unclear etiology that mainly affects males. Medical treatment of AKN is difficult, with refractory cases often requiring ablation by laser or surgical resection. We report herein, a 23-year-old male with refractory AKN treated successfully with combined laser ablation, using an 810-nm diode laser and a 1064-nm Nd:YAG laser.

  8. Physical and optical limitations using ArF-excimer and Er:YAG lasers for PRK

    Science.gov (United States)

    Semchishen, Vladimir A.; Mrochen, Michael; Seiler, Theo

    1998-06-01

    The Erbium:YAG laser emitting at a wavelength of 2,94 micrometer have been promised as an alternative laser for the ArF-excimer laser (193 nm) in photorefractive keratectomy (PRK). This report discusses the limitations of laser parameters such as wavelength, energy density and pulse duration for the ablation of the cornea. In addition, the melting process during ablation on the corneal surface roughness may play a role.

  9. PRK by Er:YAG laser: in-vitro studies and first in-vivo experiences

    Science.gov (United States)

    Steiner, Rudolf W.; Leiacker, Richard; Russ, Detlef; Seiler, Theo

    1996-01-01

    Photorefractive keratectomy (PRK) is usually performed by an excimer laser at 193 nm wavelength. Ablatio of corneal tissue is, however, not only possible in the UV region of the optical spectrum but also in the IR where water is an excellent absorber. Therefore, an Er:YAG laser was used at 2.94 micrometer wavelength as an alternative laser light source to perform in vitro studies of corneal ablation and also first clinical experiments to correct myopia of patients with blind eyes.

  10. Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.

    Science.gov (United States)

    Bath, P E; Dang, Y; Martin, W H

    1986-11-01

    A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.

  11. Instant recording of the duration of a single mode-locked Nd:YAG laser pulse

    International Nuclear Information System (INIS)

    Lompre, L.A.; Mainfray, G.; Thebault, J.

    1975-01-01

    An electro-optic streak camera incorporating a storage memory video system has been developed and used to instantly visualize and record the shape of a 1.06-μ-wavelength pulse generated by a mode-locked Nd:YAG laser. The duration of a single laser pulse (approximately 30 psec) has been directly measured with and without laser amplification. (U.S.)

  12. [Effects of Nd: YAG laser irradiation on the root surfaces and adhesion of Streptococcus mutans].

    Science.gov (United States)

    Yuanhong, Li; Zhongcheng, Li; Mengqi, Luo; Daonan, Shen; Shu, Zhang; Shu, Meng

    2016-12-01

    This study aimed to evaluate the effects of treatment with different powers of Nd: YAG laser irradiation on root surfaces and Streptococcus mutans (S. mutans) adhesion. Extracted teeth because of severe periodontal disease were divided into the following four groups: control group, laser group 1, laser group 2, and laser group 3. After scaling and root planning, laser group 1, laser group 2, and laser group 3 were separately treated with Nd: YAG laser irradiation (4/6/8 W, 60 s); however, the control group did not receive the treatment. Scanning electron microscopy (SEM) was used to determine the morphology. S. mutans were cultured with root slices from each group. Colony forming unit per mL (CFU·mL⁻¹) was used to count and compare the amounts of bacteria adhesion among groups. SEM was used to observe the difference of bacteria adhesion to root surfaces between control group (scaling) and laser group 2 (6 W, 60 s), thereby indicating the different bacteria adhesions because of different treatments. Morphology alterations indicated that root surfaces in control group contain obvious smear layer, debris, and biofilm; whereas the root surfaces in laser group contain more cracks with less smear layer and debris. The bacteria counting indicated that S. mutans adhesion to laser group was weaker than that of control group (P0.05) was observed. Morphology alterations also verified that S. mutans adhesion to laser group 2 (6 W, 60 s) was weaker than that of control group (scaling). This study demonstrated that Nd: YAG laser irradiation treatment after scaling can reduce smear layer, debris, and biofilm on the root surfaces as compared with conventional scaling. The laser treatment reduces the adhesion of S. mutans as well. However, Nd: YAG laser irradiation can cause cracks on the root surfaces. In this experiment, the optimum laser power of 6 W can thoroughly remove the smear layer and debris, as well as relatively improve the control of thermal damagee.

  13. A diode-pumped Tm:YAG laser with an elliptical cavity mode

    International Nuclear Information System (INIS)

    Lipnicki, E.; Dawes, J.M.; Browne, P.G.

    2000-01-01

    Full text: A cavity consisting of cylindrical mirrors/lenses resulting in an elliptical cavity mode is being applied to a 3-level laser; Tm:YAG which lases near 2μm. This arrangement allows the use of simple pump beam optics but also ensures efficient mode matching with good output beam quality. This cavity has been designed and modelled with experiments under way to explore the advantages of this laser design

  14. Stabilization of the quasi-periodic motion of a Q-switched Nd:YAG laser

    International Nuclear Information System (INIS)

    Kim, Chil-Min; Rim, Sunghwan; Kye, Won-Ho; Kim, Jeong-Moog; Lee, Kang-Soo

    2004-01-01

    We have developed a stabilization method of quasi-periodicity based on a return map. The method is explained in the forced Van der Pol oscillator, and applied experimentally to a quasi-periodic output of a Q-switched Nd:YAG laser. Even though the attractors have no unstable periodic orbit, we were able to stabilize them to an arbitrarily chosen orbit by targeting the trajectory into it

  15. Temperature dependence of CIE-x,y color coordinates in YAG:Ce single crystal phosphor

    Czech Academy of Sciences Publication Activity Database

    Rejman, M.; Babin, Vladimir; Kučerková, Romana; Nikl, Martin

    2017-01-01

    Roč. 187, Jul (2017), s. 20-25 ISSN 0022-2313 R&D Projects: GA TA ČR TA04010135 Institutional support: RVO:68378271 Keywords : YAG:Ce * single-crystal * simulation * energy level lifetime * white LED * CIE * temperature dependence Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 2.686, year: 2016

  16. Reduce synthesis temperature and improve dispersion of YAG nanopowders based on the co-crystallization method

    Energy Technology Data Exchange (ETDEWEB)

    Fan, G.F.; Tang, Y.Q.; Lu, W.Z., E-mail: lwz@mail.hust.edu.cn; Zhang, X.R.; Xu, X.

    2015-01-05

    Highlights: • YAG nanopowders were synthesized through a co-crystallization method. • A three-layer core–shell structure was made to lower the synthesis temperature. • PAA again reduced the synthesis temperature based on the core–shell structure. • YAG nanopowders were synthesized at 700 °C in normal apparatus. • Agglomeration was greatly improved by PAA. - Abstract: Pure yttrium aluminum garnet (YAG) nanopowders were synthesized at 950 °C from the co-crystallization precursor of Y(NO{sub 3}){sub 3}⋅6H{sub 2}O and Al(NO{sub 3}){sub 3}⋅9H{sub 2}O (nitrate process). When 17 wt.% of Y(NO{sub 3}){sub 3}⋅6H{sub 2}O was replaced by Y{sub 2}O{sub 3} nanopowders, so as to make up a three-layer core–shell structure of the precursor, the synthesis temperature was reduced to 850 °C (Y{sub 2}O{sub 3} process). Based on Y{sub 2}O{sub 3} process, further reducing the synthesis temperature to 700 °C was realized by adding polyacrylic acid (PAA, 50% M), which was used to shorten the distance of the metal ions and provide combustion heat (PAA process). TEM characterizations indicated that the powders produced through nitrate and Y{sub 2}O{sub 3} processes agglomerated, while the powders produced through PAA process were dispersed much better. The agglomerate size analysis results demonstrated that the powders produced through PAA process were with smaller agglomerate size and wider agglomerate size distribution than those through nitrate process or Y{sub 2}O{sub 3} process. And they were more likely to be sintered to YAG transparent ceramics.

  17. Test of remote control cutting equipment by Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akio [Fuji Electric Corp. Research and Development Ltd., Yokosuka, Kanagawa (Japan); Hosoda, Hiroshi

    1997-11-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  18. Effect of Er:YAG Laser and Sandblasting in Recycling of Ceramic Brackets.

    Science.gov (United States)

    Yassaei, Soghra; Aghili, Hossein; Hosseinzadeh Firouzabadi, Azadeh; Meshkani, Hamidreza

    2017-01-01

    Introduction: This study was performed to determine the shear bond strength of rebonded mechanically retentive ceramic brackets after recycling with Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser or sandblasting. Methods: Twenty-eight debonded ceramic brackets plus 14 intact new ceramic brackets were used in this study. Debonded brackets were randomly divided into 2 groups of 14. One group was treated by Er:YAG laser and the other with sandblasting. All the specimens were randomly bonded to 42 intact human upper premolars. The shear bond strength of all specimens was determined with a universal testing machine at a crosshead speed of 0.5 mm/min until bond failure occurred. The recycled bracket base surfaces were observed under a scanning electron microscope (SEM). Analysis of variance (ANOVA) and Tukey tests were used to compare the shear bond strength of the 3 groups. Fisher exact test was used to evaluate the differences in adhesive remnant index (ARI) scores. Results: The highest bond strength belonged to brackets recycled by Sandblasting (16.83 MPa). There was no significant difference between the shear bond strength of laser and control groups. SEM photographs showed differences in 2 recycling methods. The laser recycled bracket appeared to have as well-cleaned base as the new bracket. Although the sandblasted bracket photographs showed no remnant adhesives, remarkable micro-roughening of the base of the bracket was apparent. Conclusion: According to the results of this study, both Er:YAG laser and sandblasting were efficient to mechanically recondition retentive ceramic brackets. Also, Er:YAG laser did not change the design of bracket base while removing the remnant adhesives which might encourage its application in clinical practice.

  19. Enhancing the performance of Ce:YAG phosphor-in-silica-glass by controlling interface reaction

    International Nuclear Information System (INIS)

    Zhou, Beiying; Luo, Wei; Liu, Sheng; Gu, Shijia; Lu, Mengchen; Zhang, Yan; Fan, Yuchi; Jiang, Wan; Wang, Lianjun

    2017-01-01

    Dispersing the Ce"3"+ doped yttrium aluminum garnet (Ce:YAG) phosphor in the glass matrix has been widely investigated to replace conventional organic resin or silicone packaging. However, the reaction layer formed between commercial phosphors and glass matrix severely degrades the optical performance of Ce:YAG phosphor in silica glass (PiSG) materials. This paper demonstrates an ultra-fast method for preparing high performance PiSG materials. Instead of traditional melting process, the highly transparent PiSG samples can be rapidly fabricated from mixtures of commercial Ce:YAG phosphor and mesoporous SiO_2 (SBA-15) powders using spark plasma sintering (SPS) at relatively low temperature (1000 °C) within short time (10 min). Owing to the inhibition of the deleterious interface reactions between Ce:YAG phosphor and silica glass matrix, the phosphor has been perfectly preserved, and the internal relative quantum yield of the PiSG sample reaches as high as 93.5% when excited at 455 nm, which is the highest efficiency in current research. Furthermore, combining the PiSG sample, we successfully fabricate a light-emitting diode (LED) module exhibiting a superior performance with luminous efficacy of 127.9 lm/W, correlated color temperature of 5877 K and color rendering index of 69 at the operating current of 120 mA. This work on the high performance LED modules provides not only a new approach to fabricate the functional glass-based materials that is sensitive to the high temperature, but also a possibility to extend the lifetime and improve the optical performances of the glass based LEDs.

  20. New application of a bipolar Nd:YAG handpiece in laser cardiac surgery

    Science.gov (United States)

    Mizutani, Tetsuo; Suzuki, Hitoshi; Katayama, Yoshihiko

    1997-05-01

    A bipolar Nd-YAG laser (1.064 micrometer) handpiece was experimentally examined for a venous dissection without scissors and sutures and clinically introduced for the vein graft harvesting in coronary artery bypass grafting (CABG). Experimental study: One hundred and thirty-five segments of the mongrel dog veins were employed. Nd-YAG laser was irradiated on the vein held by the bipolar Nd-YAG handpiece at the power of 5, 9, 13, and 17 watts, and success defined as a complete vein citing without bleeding at the laser-applied sites were gained in all except three; 97.8% of success rate. Laser exposure time for cutting the vein decreased in order to an increase of the applied laser power, and the veins of bigger diameter needed more longer exposure time in the group of the same laser power. An average exposure time was 4.4 seconds for the veins of 1 mm diameter at 13 watts. In histological examination, a vascular lumen at the cutting site was diminished and covered with a degenerated vascular wall, and bleeding was not seen in all specimen. Clinical study: In 18 cases of CABG the bipolar Nd-YAG handpiece was applied to cut the branches of the great saphenous vein without scissors and sutures. Forty-two grafts harvested by this handpiece were used for aortocoronary bypass grating. All were survived and the angiographic examination demonstrated a 90% of graft patency at an average period of 3.5 years after the operation. Laser-induced morphological change such as aneurysmal formation or graft stenosis was not recognized.

  1. Hot cracking characteristic of welding using Nd:YAG laser beam

    International Nuclear Information System (INIS)

    Ro, Kyoung Bo; Yoo, Young Tae; Oh, Yong Seak; Shin, Ho Jun; Kim, Ji Hwan

    2003-01-01

    The Nd:YAG laser process is known to have high speed and deep penetration capability to become one of the most advanced welding technologies. In spite of its good mechanical characteristics, SM45C carbon steel has a high carbon contents and suffers a limitation in the industrial application due to the poor welding properties. The major process parameters studied in the present laser welding experiment were position of focus, travel speed and laser power

  2. Study of spatial resolution of YAG:Ce cathodoluminescent imaging screens

    Czech Academy of Sciences Publication Activity Database

    Schauer, Petr; Bok, Jan

    2013-01-01

    Roč. 308, 1 August (2013), s. 68-73 ISSN 0168-583X R&D Projects: GA TA ČR TE01020118; GA ČR GAP102/10/1410; GA MŠk EE.2.3.20.0103 Institutional support: RVO:68081731 Keywords : Spatial resolution * Imaging screen * Electron microscope * Cathodoluminescence * YAG:Ce single crystal * Line spread function * Modulation transfer function Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.186, year: 2013

  3. Test of remote control cutting equipment by Nd:YAG laser

    International Nuclear Information System (INIS)

    Shimizu, Akio; Hosoda, Hiroshi.

    1997-01-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  4. Marketingový mix výrobního družstva IRISA

    OpenAIRE

    Nguyen, Anh Duc

    2016-01-01

    Tato bakalářská práce je zaměřena marketing a konkrétně na marketingový mix produktů. V teoretické části vysvětlím základní pojmy marketingu a marketingového mixu. V analytické části provedu analýzy marketingového mixu vybraného podniku. V návrhové části sestavím návrhy na změny současného marketingového mixu. This thesis is focused specifically on marketing and marketing mix of products. The theoretical part explains the basic concepts of marketing and marketing mix. The analytical part w...

  5. Superdeformation studies in {sup 150}Tb and {sup 153}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Nisius, D.; Janssens, R.V.F.; Crowell, B. [and others

    1995-08-01

    There are now over 40 superdeformed (SD) bands known in the A {approximately} 150 region and in most cases the properties of these bands are understood in terms of single-particle excitations in the absence of pairing. By continuing the search for new SD bands we hope to gain insight into (1) the ordering of the proton and neutron orbitals near the Fermi surface in the SD well, (2) the effects that the alignment of those orbitals has on the moments of inertia, and (3) the collective excitations in the SD well. For {sup 150}Tb, which is one proton and one neutron away from the SD doubly-magic nucleus {sup 152}Dy, it should be possible to study SD bands based on both proton and neutron hole excitations. By adding one proton to the {sup 152}Dy nucleus (i.e. {sup 153}Ho) proton excitations above the Z = 66 shell gap can be studied. These excitations are important as calculations suggested that the proton intruder orbital N = 7 might become occupied. Interactions between this orbital and a N = 5 level may result in softness towards octupole vibrations. High spin states in {sup 150}Th and {sup 153}Ho were populated using the {sup 124}Sn({sup 31}P,5n) and {sup 120}Sn({sup 37}Cl,4n) reactions, respectively. In both cases the early implementation phase of Gammasphere was used to detect the decay gamma rays and over 1 x 10{sup 9} triple and higher fold coincidence events were recorded. In {sup 150}Tb, the data analysis is complete and two new SD bands were identified. The fact that Im{sup (2)} moments of inertia are sensitive to the specific high-N intruder content of the SD bands was used to suggest configurations for the two new bands. A paper reporting these results is being prepared. For {sup 153}Ho, data analysis is still in its early stages.

  6. Optical spectroscopy in channel waveguides made in Nd:YAG crystals by femtosecond laser writing

    International Nuclear Information System (INIS)

    Torchia, G.A.; Mendez, C.; Roso, L.; Tocho, J.O.

    2008-01-01

    In this work, we present an optical characterization of channel waveguides fabricated by means of femtosecond laser writing on Nd:YAG substrates. These guiding structures show a refractive index increment of about 1x10 -3 which allows TE propagation. By pumping with a CW solid-state laser at 532 nm reaching the 2 G 9/2 and 4 G 7/2 manifolds of Nd 3+ ions, we have explored the emission band corresponding to 4 F 3/2 → 4 I 9/2 optical transitions (peaked at 890 nm). From data, we have found that emission showed similar characteristics for waveguide and bulk. On the other hand, the lifetime corresponding to the 4 F 3/2 metaestable level was determined to be 240 μs for bulk and waveguide. Summarizing, we have made suitable channel waveguides in Nd:YAG crystals, by fs interaction, with similar spectroscopic properties to those of the bulk, a fact that boosters the photonics application of these devices. For the first time to our knowledge, a direct index increment waveguide made by interaction with ultra-short intense pulses in YAG crystals has been performed. This fabrication procedure can be an efficient tool to make several optical circuits in active materials by means of the one-step, fast and low-cost processing

  7. Flaw evaluation of Nd:YAG laser welding based plume shape by infrared thermal camera

    International Nuclear Information System (INIS)

    Kim, Jae Yeol; Yoo, Young Tae; Yang, Dong Jo; Song, Kyung Seol; Ro, Kyoung Bo

    2003-01-01

    In Nd:YAG laser welding evaluation methods of welding flaw are various. But, the method due to plume shape is difficult to classification od welding flaw. The Nd:YAG laser process is known to have high speed and deep penetration capability to become one of the most advanced welding technologies. At the present time, some methods are studied for measurement of plume shape by using high-speed camera and photo diode. This paper describes the machining characteristics of SM45C carbon steel welding by use of an Nd:YAG laser. In spite of its good mechanical characteristics, SM45C carbon steel has a high carbon contents and suffers a limitation in the industrial application due to the poor welding properties. In this study, plume shape was measured by infrared thermal camera that is non-contact/non-destructive thermal measurement equipment through change of laser generating power, speed, focus. Weld was performed on bead-on method. Measurement results are compared as two equipment. Here, two results are composed of measurement results of plume quantities due to plume shape by infrared thermal camera and inspection results of weld bead include weld flaws by ultrasonic inspector.

  8. Effect of Annealing Time of YAG:Ce3+ Phosphor on White Light Chromaticity Values

    Science.gov (United States)

    Abd, Husnen R.; Hassan, Z.; Ahmed, Naser M.; Almessiere, Munirah Abdullah; Omar, A. F.; Alsultany, Forat H.; Sabah, Fayroz A.; Osman, Ummu Shuhada

    2018-02-01

    Yttrium and aluminium nitrate phosphors doped with cerium nitrate and mixed with urea (fuel) are prepared by using microwave-induced combustion synthesis according to the formula Y(3-0.06)Al5O12:0.06Ce3+ (YAG:Ce3+) to produce white light emitting diodes by conversion from blue indium gallium nitride-light emitting diode chips. The sintering time with fixed temperature (1050°C) for phosphor powder was optimized and found to be 5 h. The crystallinity, structure, chemical composition, luminescent properties with varying currents densities and chromaticity were characterized by x-ray diffraction, field emission-scanning electron microscopy, transmission electron microscopy, energy dispersive spectroscopy, photoluminescence emission, electroluminescence and standard CIE 1931 chromaticity diagram, respectively. The energy levels of Ce3+ in YAG were discussed based on its absorption and excitation spectra. The results show that the obtained YAG:Ce3+ phosphor sintered for 5 h has good crystallinity with pure phase, low agglomerate with spherical shaped particles and strong yellow emission, offering cool-white LED with tuneable correlated color temperature and a good color rendering index compared to those prepared by sintering for 2 h and as-prepared phosphor powders.

  9. Simulation of medical Q-switch flash-pumped Er:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yanlin; Huang Chuyun; Yao Yucheng; Zou Xiaolin, E-mail: Wangyanlin0@126.com, E-mail: chuyunh@163.com, E-mail: yyuch@soho.com, E-mail: zouxiaol@126.com [Physics school, Hubei University of Technology, Wuhan, China 430068 (China)

    2011-01-01

    Er: YAG laser, the wavelength is 2940nm, can be absorbed strongly by water. The absorption coefficient is as high as 13000 cm{sup -1}. As the water strong absorption, Erbium laser can bring shallow penetration depth and smaller surrounding tissue injury in most soft tissue and hard tissue. At the same time, the interaction between 2940nm radiation and biological tissue saturated with water is equivalent to instantaneous heating within limited volume, thus resulting in the phenomenon of micro-explosion to removal organization. Different parameters can be set up to cut enamel, dentin, caries and soft tissue. For the development and optimization of laser system, it is a practical choice to use laser modeling to predict the influence of various parameters for laser performance. Aim at the status of low Erbium laser output power, flash-pumped Er: YAG laser performance was simulated to obtain optical output in theory. the rate equation model was obtained and used to predict the change of population densities in various manifolds and use the technology of Q-switch the simulate laser output for different design parameters and results showed that Er: YAG laser output energy can achieve the maximum average output power of 9.8W under the given parameters. The model can be used to find the potential laser systems that meet application requirements.

  10. Temperature dependence of optical properties in Nd/Cr:YAG materials

    International Nuclear Information System (INIS)

    Honda, Yoshiyuki; Motokoshi, Shinji; Jitsuno, Takahisa; Miyanaga, Noriaki; Fujioka, Kana; Nakatsuka, Masahiro; Yoshida, Minoru

    2014-01-01

    The energy transfer from Cr 3+ to Nd 3+ for Nd/Cr:YAG (Nd: 1.0%, Cr: 2.0%) materials was investigated by measuring the temperature dependences of fluorescence characteristics. The fluorescence intensity of Nd 3+ increased with temperature owing to enhancement of the absorption coefficient of Cr 3+ . The energy transfer efficiency was constant from 77 to 450 K. The energy transfer time decreased with increasing temperature. -- Highlights: • We investigate the energy transfer from Cr 3+ to Nd 3+ in Nd/Cr:YAG materials by measuring the temperature dependence of fluorescence characteristics. • The fluorescence intensity of Nd 3+ increased with temperature owing to enhancement of the absorption coefficient of Cr 3+ . • The energy transfer efficiency was constant from 77 to 450 K. • The energy transfer time decreased with increasing temperature. • Nd/Cr:YAG ceramics pumped by a flash lamp would not only provide high conversion efficiency, but can also be expected to function as an effective laser operating at high temperature

  11. Femtosecond laser irradiation on Nd:YAG crystal: Surface ablation and high-spatial-frequency nanograting

    Science.gov (United States)

    Ren, Yingying; Zhang, Limu; Romero, Carolina; Vázquez de Aldana, Javier R.; Chen, Feng

    2018-05-01

    In this work, we systematically study the surface modifications of femtosecond (fs) laser irradiated Nd:YAG crystal in stationary focusing case (i.e., the beam focused on the target in the steady focusing geometry) or dynamic scanning case (i.e., focused fs-laser beam scanning over the target material). Micro-sized structures (e.g. micro-craters or lines) are experimentally produced in a large scale of parameters in terms of pulse energy as well as (effective) pulse number. Surface ablation of Nd:YAG surface under both processing cases are investigated, involving the morphological evolution, parameter dependence, the ablation threshold fluences and the incubation factors. Meanwhile, under specific irradiation conditions, periodic surface structures with high-spatial-frequency (Investigations on the evolution of nanograting formation and fluence dependence of period are performed. The experimental results obtained under different cases and the comparison between them reveal that incubation effect plays an important role not only in the ablation of Nd:YAG surface but also in the processes of nanograting formation.

  12. Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin.

    Science.gov (United States)

    Archilla, José R F; Moreira, Maria S N A; Miyagi, Sueli P H; Bombana, Antônio C; Gutknecht, Norbert; Marques, Márcia M

    2012-11-01

    Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124  J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.

  13. Utilization of Nd-YAG (1064 nm) laser for female hair removal

    International Nuclear Information System (INIS)

    Ahmed, Ahlam Hassan

    2013-05-01

    The Cutera. Inc, cool Glide system laser is along pulsed Nd-YAG 1064 nm, of energy density 25 to 30 J/cm 2 and pulse duration 25 ms in all individual sessions.This study was held in Medical Arms Service Hospital. The period of study taken was three month. The study sample consisted of five patients base line photographs were taken before treatments and also after treatments. Photos show the satisfactory results of the laser treatment. In this study the hair removal treat went was conducted for female middle age group of 25-40 years. The Nd-YAG (1064 nm) laser was found to more effective in treatment of the hair removal, and complications can be minimized by using anesthesia and anti bio tics. The Nd-YAG laser therapy should be considered as a good and dependable alternative to other treatment radiation techniques. And effectiveness of treatment can be increased by using optimum power and duration.(Author)

  14. Nd:YAG laser for epithelial ingrowth after laser in situ keratomileusis.

    Science.gov (United States)

    Mohammed, Osama Ali; Mounir, Amr; Hassan, Amin Aboali; Alsmman, Alahmady Hamad; Mostafa, Engy Mohamed

    2018-05-04

    To evaluate the efficacy of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser for treatment of epithelial ingrowth after laser in situ keratomileusis (LASIK). Fifty-eight patients with epithelial ingrowth presented to Sohag refractive center, Sohag, Egypt, between January 2015 and March 2017. Only 41 patients (18 females and 23 males, mean age: 33.4 years) involving 41 eyes were indicated for treatment by Nd:YAG laser as the rest of the eyes were only under observation. Patients with epithelial ingrowth were recognized at a mean of 6 months after primary LASIK procedure (range: 2-16 months). Four eyes had undergone previous LASIK enhancements. Four eyes had the epithelial ingrowth removed by flap lift and scrapping. The mean intensity of the spots used was 0.8 mJ with variable number of shots depending on the size and density of the epithelial ingrowth area. Twenty-eight eyes showed complete regression after one session, while the rest necessitated 2-3 sessions for complete resolution. Mean follow-up period was 8 months (range 5-12 months). Epithelial ingrowth was treated successfully in all 41 eyes. The uncorrected visual acuities were 20/20, and there was no evidence of recurrent epithelial ingrowth after 6 months with no complications reported. YAG laser is a simple, effective outpatient procedure for the management of epithelial ingrowth after LASIK.

  15. Nd:YAG transparent ceramics fabricated by direct cold isostatic pressing and vacuum sintering

    Science.gov (United States)

    Ge, Lin; Li, Jiang; Zhou, Zhiwei; Liu, Binglong; Xie, Tengfei; Liu, Jing; Kou, Huamin; Shi, Yun; Pan, Yubai; Guo, Jingkun

    2015-12-01

    The sintering behavior of neodymium doped yttrium aluminum garnet (Nd:YAG) ceramics was investigated on the basis of densification trajectory, microstructure evolution and transmittance. Nd:YAG ceramics with in-line transmittance of 83.9% at 1064 nm and 82.5% at 400 nm were obtained by direct cold isostatic pressing (CIP) at 250 MPa and solid-state reactive sintering at 1790 °C for 30 h under vacuum. Compared with the porosity and the average pore diameter of the sample from uniaxial dry-pressing followed by CIP, those from direct CIP are much smaller. The samples pressed at 250 MPa were sintered from 1500 °C to 1750 °C for 0.5-20 h to study their sintering behavior. At the temperature higher than 1500 °C, pure YAG phase is formed, followed by the densification and grain growth process. The relative density and the grain size increase with the increase of sintering time and temperature, and the sintering behavior is more sensitive to temperature than holding time. The mechanism controlling densification and grain growth at sintering temperature of 1550 °C is grain boundary diffusion.

  16. Holmium:YAG laser effects on articular cartilage metabolism: in vitro

    Science.gov (United States)

    Smith, R. Lane; Montgomery, L.; Fanton, G.; Dillingham, M.; Schurman, D. J.

    1994-09-01

    We report effects of applying variable doses of Holmium:YAG laser energy to bovine articular cartilage in vitro. The response of the cartilage to the Holmium:YAG laser energy was determined by quantification of cell proliferation and extracellular matrix glycosaminoglycan synthesis. This study demonstrates that articular cartilage cell metabolism was maintained at a normal level following treatment of cartilage at a dose of 0.6 joules/pulse. The laser energy was applied at 10 Hz for 10 seconds at 1 mm distance from the cartilage. Under these conditions and at a dose of 0.6 joules/pulse, the total energy density was calculated to be 240 joules/cm2, assuming minimal loss of energy due to water absorption. Energy levels grater than 0.8 joules/pulse corresponding to calculated energy densities greater than 320 joules/cm2 proved harmful to cartilage. Our data demonstrate that low levels of Holmium:YAG laser energy can be applied to articular cartilage under conditions that maintain and/or stimulate cell metabolism.

  17. Single session of Nd:YAG laser intracanal irradiation neutralizes endotoxin in dental root dentin

    Science.gov (United States)

    Archilla, José R. F.; Moreira, Maria S. N. A.; Miyagi, Sueli P. H.; Bombana, Antônio C.; Gutknecht, Norbert; Marques, Márcia M.

    2012-11-01

    Endotoxins released in the dental root by Gram-negative microorganisms can be neutralized by calcium hydroxide, when this medication is applied inside the root canal for at least seven days. However, several clinical situations demand faster root canal decontamination. Thus, for faster endotoxin neutralization, endodontists are seeking additional treatments. The in vitro study tested whether or not intracanal Nd:YAG laser irradiation would be able to neutralize endotoxin within the human dental root canal in a single session. Twenty-four human teeth with one root were mounted between two chambers. After conventional endodontic treatment, root canals were contaminated with Escherichia coli endotoxin. Then they were irradiated or not (controls) in contact mode with an Nd:YAG laser (1.5 W, 15 Hz, 100 mJ and pulse fluency of 124 J/cm2). The endotoxin activity was measured using the limulus lysate technique and data were statistically compared (p≤0.05). The concentration of active endotoxin measured in the negative control group was significantly lower than that of the positive control group (p=0.04). The concentrations of endotoxin in both irradiated groups were significantly lower than that of the positive control group (p=0.027) and similar to that of negative control group (p=0.20). A single session of intracanal Nd:YAG laser irradiation is able to neutralize endotoxin in the dental root tissues.

  18. Enamel resistance to demineralization following Er:YAG laser etching for bonding orthodontic brackets

    Science.gov (United States)

    Ahrari, Farzaneh; Poosti, Maryam; Motahari, Pourya

    2012-01-01

    Background: Several studies have shown that laser-etching of enamel for bonding orthodontic brackets could be an appropriate alternative for acid conditioning, since a potential advantage of laser could or might be caries prevention. This study compared enamel resistance to demineralization following etching with acid phosphoric or Er:YAG laser for bonding orthodontic brackets. Materials and Methods: Fifty sound human premolars were divided into two equal groups. In the first group, enamel was etched with 37% phosphoric acid for 15 seconds. In the second group, Er:YAG laser (wavelength, 2 940 nm; 300 mJ/pulse, 10 pulses per second, 10 seconds) was used for tooth conditioning. The teeth were subjected to 4-day PH-cycling process to induce caries-like lesions. The teeth were then sectioned and the surface area of the lesion was calculated in each microphotographs and expressed in pixel. The total surface of each specimen was 196 608 pixels. Results: Mean lesion areas were 7 171 and 7532 pixels for Laser-etched and Acid-etched groups, respectively. The two sample t-test showed that there was no significant difference in lesion area between the two groups (P = 0.914). Conclusion: Although Er:YAG laser seems promising for etching enamel before bonding orthodontic brackets, it does not reduce enamel demineralization when exposed to acid challenge. PMID:23162591

  19. Depigmentation therapy with Q-switched Nd: YAG laser in universal vitiligo

    Directory of Open Access Journals (Sweden)

    Imran Majid

    2013-01-01

    Full Text Available Background: Any residual pigment left in patients of universal vitiligo is managed with topical treatments, cryotherapy, and lasers. Aim: The study aims to assess the efficacy and safety of Q-switched Nd: YAG laser in treating the residual pigmentation in patients with universal vitiligo. Materials and Methods: Fifteen patients of universal vitiligo with residual pigmentation on the face, hands, or feet, resistant to topical treatments, were treated with single or multiple sessions of Q-switched Nd: YAG laser treatment. Topical treatments were continued in between the laser sessions and the depigmentation achieved was monitored by clinical examination and repeat digital photographs. Response to the treatment was labelled as excellent if the residual pigment could be reduced by at least 90% while 50-90% resolution of pigmentation was labelled as a partial response. Adverse effects to the treatment offered were also monitored. Results: Thirteen of the 15 patients enrolled for the study showed an excellent response to the treatment offered. Two other patients showed a poor response with less than 50% resolution of pigmentation. The number of laser sessions needed at a particular site ranged from 1 to 3 and no patient was offered more than three sessions of laser treatment at any site. No significant adverse events were reported by any patient. Conclusions: Residual pigmentation in patients with universal vitiligo that does not respond to topical treatment options alone can be managed quite effectively with Q-switched Nd: YAG laser without any significant adverse effects.

  20. Sub ablative Er: YAG laser irradiation on surface roughness of eroded dental enamel.

    Science.gov (United States)

    Curylofo-Zotti, Fabiana Almeida; Lepri, Taísa Penazzo; Colucci, Vivian; Turssi, Cecília Pedroso; Corona, Silmara Aparecida Milori

    2015-11-01

    This study evaluated the effects of Er:YAG laser irradiation applied at varying pulse repetition rate on the surface roughness of eroded enamel. Bovine enamel slabs (n = 10) were embedded in polyester resin, ground, and polished. To erosive challenges, specimens were immersed two times per day in 20mL of concentrated orange juice (pH = 3.84) under agitation, during a two-day period. Specimens were randomly assigned to irradiation with the Er:YAG laser (focused mode, pulse energy of 60 mJ and energy density of 3.79 J/cm(2) ) operating at 1, 2, 3, or 4 Hz. The control group was left nonirradiated. Surface roughness measurements were recorded post erosion-like formation and further erosive episodes by a profilometer and observed through atomic force microscopy (AFM). Analysis of variance revealed that the control group showed the lowest surface roughness, while laser-irradiated substrates did not differ from each other following post erosion-like lesion formation. According to analysis of covariance, at further erosive episodes, the control group demonstrated lower surface roughness (P > 0.05), than any of the irradiated groups (P enamel eroded. The AFM images showed that the specimens irradiated by the Er:YAG laser at 1 Hz presented a less rough surface than those irradiated at 2, 3, and 4 Hz. © 2015 Wiley Periodicals, Inc.

  1. Morphological changes produced by acid dissolution in Er:YAG laser irradiated dental enamel.

    Science.gov (United States)

    Manuela Díaz-Monroy, Jennifer; Contreras-Bulnes, Rosalía; Fernando Olea-Mejía, Oscar; Emma Rodríguez-Vilchis, Laura; Sanchez-Flores, Ignacio

    2014-06-01

    Several scientific reports have shown the effects of Er:YAG laser irradiation on enamel morphology. However, there is lack of information regarding the morphological alterations produced by the acid attack on the irradiated surfaces. The aim of this study was to evaluate the morphological changes produced by acid dissolution in Er:YAG laser irradiated dental enamel. Forty-eight enamel samples were divided into four groups (n = 12). GI (control); Groups II, III, and IV were irradiated with Er:YAG at 100 mJ (12.7 J/cm(2) ), 200 mJ (25.5 J/cm(2) ), and 300 mJ (38.2 J/cm(2) ), respectively, at 10 Hz without water irrigation. Enamel morphology was evaluated before-irradiation, after-irradiation, and after-acid dissolution, by scanning electron microscopy (SEM). Sample coating was avoided and SEM analysis was performed in a low-vacuum mode. To facilitate the location of the assessment area, a reference point was marked. Morphological changes produced by acid dissolution of irradiated enamel were observed, specifically on laser-induced undesired effects. These morphological changes were from mild to severe, depending on the presence of after-irradiation undesired effects. © 2014 Wiley Periodicals, Inc.

  2. Growth and characterization of air annealing Mn-doped YAG:Ce single crystal for LED

    International Nuclear Information System (INIS)

    Xiang, Weidong; Zhong, Jiasong; Zhao, Yinsheng; Zhao, Binyu; Liang, Xiaojuan; Dong, Yongjun; Zhang, Zhimin; Chen, Zhaoping; Liu, Bingfeng

    2012-01-01

    Highlights: ► The YAG:Ce,Mn single crystal was well synthesized by the Czochralski (CZ) method. ► The emission intensity of the sample has been influenced after annealing. ► Annealed in the air at 1200 °C was the most optimal annealing condition. ► The single crystal could be used in the white light LED which emitted by blue light. - Abstract: The growth of Mn-doped YAG:Ce (yttrium aluminum garnet doped cerium) single crystal by the Czochralski (CZ) method and the characterization of its spectroscopy and color-electric parameters are presented. The absorption spectra indicate that the crystal absorbed highly in the 300–500 nm wavelength range. The emission spectrum of the crystal consists of a peak around 538 nm when excited by 460 nm blue light, which prove the YAG:Ce,Mn single crystal could be used in the white light emitting doides (LED). The different charges of Mn ions have different luminescence properties, and the air annealing process for the single crystal would change the concentration of Mn ions with different charges, which could influence the emission intensity of the single crystal.

  3. Er:YAG laser-assisted hair transplantation in cicatricial alopecia.

    Science.gov (United States)

    Podda, M; Spieth, K; Kaufmann, R

    2000-11-01

    Autologous hair transplantation and its combination with flap or reduction procedures is a common surgical approach to cover defects in cicatricial alopecias. Due to the poor recipient conditions present in scar tissue, it is crucial to minimize the trauma exerted on implantation holes in order to achieve good transplantation results. We sought to evaluate the "cold"-ablative properties of the Er:YAG laser for the generation of recipient holes in cicatricial alopecia. Patients with cicatricial alopecia of diverse etiology were treated with Er:YAG laser-assisted hair transplantation. Mini- or micrografts were inserted into recipient holes ablated with a pulse energy of 900-1200 mJ and a spot size of 1.0-1.6 mm. A fluence of 80-120 J/cm2 and 8-12 pulses gave an almost ideal combination of minimal thermal damage and tissue ablation down to the subcutis. With an apparent mini- and micrograft survival of 95% we achieved good cosmetic results after two to five transplant sessions in all patients. The Er:YAG laser is a novel effective tool to ablate recipient holes for autologous hair transplantation in cicatricial alopecia.

  4. YAG:Dy – Based single white light emitting phosphor produced by solution combustion synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Carreira, J.F.C., E-mail: correiacarreira@ua.pt; Sedrine, N. Ben; Monteiro, T.; Rino, L.

    2017-03-15

    Dysprosium-doped yttrium aluminum garnet (YAG:Dy) phosphor was successfully produced by a Solution Combustion Synthesis (SCS) using a mixture of two fuels (urea and glycine). The effects of Dy concentration and annealing temperature were studied by X-ray diffraction (XRD), Raman spectroscopy (RS), photoluminescence (PL) and photoluminescence excitation (PLE). X-ray diffraction results show that the phosphors are single phase YAG with crystallite size ranging from 45 to 82 nm. Raman spectroscopy corroborates these results and show that the introduction of Dy ions in the YAG lattice results in additional Raman modes. Room temperature photoluminescence results confirm the introduction of the ion in the host lattice and its optical activation for all the Dy concentrations. CIE1931 color coordinates show that the samples’ emission lays in the near white region. The highest intraionic emission intensity was achieved for a Dy concentration of 2 mol% and annealing temperature of 1400 °C. Photoluminescence excitation results show that the ions luminescence is preferential excited with 351.8 and 365.8 nm wavelength photons.

  5. Inhibition of enamel demineralisation using "Nd-YAG and diode laser assisted fluoride therapy".

    Science.gov (United States)

    Chand, B R; Kulkarni, S; Mishra, P

    2016-02-01

    This in vitro study was to evaluate the irradiation efficacy of the Diode laser and the Nd-YAG laser either un-assisted or assisted by acidulated phosphate fluoride (APF) treatment on enamel's acid resistance. Seventy-two enamel samples, obtained from 12 extracted human molars, were randomly assigned to 6 groups as follows: (1) Control (C); (2) Exposed to APF gel (F); (3) Diode laser (DL); (4) Irradiated with Diode laser through APF gel (DL/F); (5) Nd-YAG laser (NL) and (6) Irradiated with Nd-YAG laser through APF gel (NL/F). The specimens were individually demineralised in an acidified hydroxyethylcellulose system, and the acid resistance was evaluated by determining the calcium ion dissolution using atomic absorption spectrometry. The average concentration of the calcium ion determined in groups 1 to 6 was 901, 757, 736, 592, 497 and 416 parts per million micrograms/gram, respectively. The results showed that demineralisation in the NL/F group was significantly less than the other groups and the control group was significantly greater than the other groups (P laser irradiation, used alone or in combination with APF, in decreasing the enamel demineralisation was greater than all the other groups.

  6. In vitro study of temperature changes in root during Er:YAG laser application

    International Nuclear Information System (INIS)

    Brandao, Redson Vilela

    2001-01-01

    The temperature increase in root dentine irradiated by Er:YAG laser beam was analyzed, for different dentine thickness and different energy and frequency conditions, aiming the evaluation of Er:YAG laser in endodontic therapy, without causing any damages to close tissues. Twenty four human teeth were separated in four groups with six teeth each, and longitudinally sectioned in thickness of 0.5 mm (first group), 1,0 mm (second group), 1,5 mm (third group) and 2,0 mm (fourth group). Those samples were irradiated with the Er:YAG laser, emitting at the wavelength of 2.94μm, by using a sapphire optic fiber with diameter of 0.375 mm, and forming an angle of 5 deg with the irradiated dentine surface. Three different laser energies were used in this study, 180 mJ, 160 mJ and 140 mJ, with frequencies of 10 Hz and 15 Hz. The temperature data were collected in a digital-analog system and sent to a computer for analysis. It was verified that the time for temperature increases of 5 deg in the external root walls varies according to the laser energy, repetition rate and dentine root thickness. Thus, in this work we could obtain laser parameters to avoid thermal damages in periodontal tissues. (author)

  7. Treatment of recurrent pilonidal cysts with nd-YAG laser: report of our experience.

    Science.gov (United States)

    Dragoni, F; Moretti, S; Cannarozzo, G; Campolmi, P

    2018-02-01

    Surgical treatment remains the first-line therapy of pilonidal cyst but is associated with high levels of postoperative pain, adverse events and a recurrence rate of 30%. We report our experience with laser hair removal using the Nd-YAG laser for the treatment of pilonidal cyst. Ten patients affected by pilonidal cyst were examined and treated from October 2011 to November 2016. Treatments were carried out using the Nd-YAG laser (Deka M.E.L.A, Calenzano, Florence, Italy) at a wavelength of 1064 nm at 30-day interval. Nine patients were asymptomatic after the second treatment, while in one case the symptom disappeared after the fourth session. After 4-8 treatments, the pilonidal cyst had clinically disappeared and patients subjectively felt healed. In all cases, the soft-tissue ultrasounds performed before the first and after the last session showed the disappearance of the pilonidal cyst. In the follow-up, all the patients remained asymptomatic without any disease recurrence. Nd-YAG laser is an effective treatment for pilonidal cysts, providing excellent results with quick healing and no risk of serious adverse side-effects. It could be a very attractive alternative to open surgery, enabling patients to prevent the frequent and severe postoperative issues associated with surgery.

  8. Dy163-Ho163 branching: an s-process barometer

    International Nuclear Information System (INIS)

    Beer, H.; Walter, G.; Macklin, R.L.

    1984-01-01

    The neutron capture cross sections of Dy163 and Er164 have been measured to analyze the s-process branching at Dy163-Ho163. The reproduction of the s-process abundance of Er164 via this branching is sensitive to temperature kT, neutron density, and electron density n/sub e/. The calculations using information from other branchings on kT and the neutron density n/sub n/ give constraints for n/sub e/ at the site of the s-process

  9. The complexes of Ho with methylenediphosphonate and 1 hydroxyethylidenephosphonate

    International Nuclear Information System (INIS)

    Vanura, P.; Jedinakova-Krizova, V.; Hakenova, L.; Munesawa, Y.

    1999-01-01

    The composition and stability of holmium methylenediphosphonate (MDP) and 1-hydroxyethylidenephosphonate (HEDP) complexes in the aqueous solution of 0.1 M NaCl at the temperature of 25 grad C were studied by potentiometric titration methods. The complexes of the composition HoH n L have been found in the aqueous solution if the concentration of the ligand is higher than the concentration of holmium. The protonation constants of both acids and stability constants of all complexes were determined and the comparison with literature data of analogical complexes of other lanthanides was performed. (authors)

  10. Ultra-violet emission in Ho:ZBLAN fiber

    International Nuclear Information System (INIS)

    Kowalska, M.; Klocek, G.; Piramidowicz, R.; Malinowski, M.

    2004-01-01

    We report on the short wavelength (green, blue, and ultra-violet (UV)) emission in trivalent holmium doped fluoro-zirconate fiber (Ho 3+ :ZBLAN) under direct and upconversion pumping. Efficient red to UV upconversion has been observed using 647 nm cw pumping by krypton ion laser. A close to cubic UV signal intensity dependence on incident red pump power was determined, confirming the three-photon character of the observed process. The responsible upconversion mechanisms were investigated and shown to be excited state absorption (ESA) via low-lying 5 I 7 and 5 I 6 sates. Dynamics of the involved excited states have been studied under pulsed laser excitation

  11. Heme oxygenase-1 (HO-1) inhibits postmyocardial infarct remodeling and restores ventricular function.

    Science.gov (United States)

    Liu, Xiaoli; Pachori, Alok S; Ward, Christopher A; Davis, J Paul; Gnecchi, Massimiliano; Kong, Deling; Zhang, Lunan; Murduck, Jared; Yet, Shaw-Fang; Perrella, Mark A; Pratt, Richard E; Dzau, Victor J; Melo, Luis G

    2006-02-01

    We reported previously that predelivery of the anti-oxidant gene heme oxygenase-1 (HO-1) to the heart by adeno associated virus (AAV) markedly reduces injury after acute myocardial infarction (MI). However, the effect of HO-1 gene delivery on postinfarction recovery has not been investigated. In the current study, we assessed the effect of HO-1 gene delivery on post-MI left ventricle (LV) remodeling and function using echocardiographic imaging and histomorphometric approaches. Two groups of Sprague-Dawley rats were injected with 4 x 10(11) particles of AAV-LacZ (control) or AAV-hHO-1 in the LV wall. Eight wk after gene transfer, the animals were subjected to 30 min of ischemia by ligation of left anterior descending artery (LAD) followed by reperfusion. Echocardiographic measurements were obtained in a blinded fashion prior and at 1.5 and 3 months after I/R. Ejection fraction (EF) was reduced by 13% and 40% in the HO-1 and LacZ groups, respectively at 1.5 months after MI. Three months after MI, EF recovered fully in the HO-1, but only partially in the LacZ-treated animals. Post-MI LV dimensions were markedly increased and the anterior wall was markedly thinned in the LacZ-treated animals compared with the HO-1-treated animals. Significant myocardial scarring and fibrosis were observed in the LacZ-group in association with elevated levels of interstitial collagen I and III and MMP-2 activity. Post-MI myofibroblast accumulation was reduced in the HO-1-treated animals, and retroviral overexpression of HO-1 reduced proliferation of isolated cardiac fibroblasts. Our data indicate that rAAV-HO-1 gene transfer markedly reduces fibrosis and ventricular remodeling and restores LV function and chamber dimensions after myocardial infarction.

  12. Marginal microleakage in vitro study of occlusal fissures sealing prepared and etched or not with Er: YAG laser; Avaliacao in vitro da microinfiltracao marginal em selamentos oclusais preparados e condicionados ou nao pelo laser de Er:YAG

    Energy Technology Data Exchange (ETDEWEB)

    Youssef, Fernanda de Almeida

    2004-07-01

    The aim of this in vitro study was to evaluate the degree of marginal microleakage in occlusal sealing by invasive techniques, after preparation with Er:YAG laser followed or not by Er:YAG laser etching and compared to the conventional technique. Thirty human premolars were divided into three groups: A (control group) - cavities were prepared with high speed and etched with 37% orthophosphoric acid; group B - cavities were prepared with Er:YAG (350 mJ, 4 Hz and 112 J /cm{sup 2}) and etched with 37% orthophosphoric acid; group C - cavities were prepared with Er:YAG laser (350 mJ, 4 Hz and 112 J/cm{sup 2}), and etched with Er:YAG laser (80 mJ, 4 Hz and 25 m/cm{sup 2}). All cavities were treated with the same adhesive system and restored with flow composite according to manufacturer instructions. Teeth were submitted to thermal cycling procedures and immersed in 50% Silver Nitrate Solutions for 8 hours in total darkness. Teeth were sectioned longitudinally in the bucco-lingual direction, in slices of 1 mm thick. Each slice was immersed into photo developing solution under 16 hours of fluorescent light. Slices were photographed and microleakage was scored from 0 to 7 J by three standard examiners. Results showed statistically significant differences for group C (Er:YAG laser preparation and etching). We concluded that Er:YAG laser can be used for cavity preparation of occlusal sealing, like the conventional high speed method. However, this laser, used as enamel etching agent, could not promote an adequate surface for adhesive procedures. (author)

  13. Effect of neodymium:YAG laser capsulotomy on visual function in patients with posterior capsule opacification and good visual acuity.

    Science.gov (United States)

    Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo

    2016-03-01

    To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Marginal microleakage in vitro study of occlusal fissures sealing prepared and etched or not with Er: YAG laser

    International Nuclear Information System (INIS)

    Youssef, Fernanda de Almeida

    2004-01-01

    The aim of this in vitro study was to evaluate the degree of marginal microleakage in occlusal sealing by invasive techniques, after preparation with Er:YAG laser followed or not by Er:YAG laser etching and compared to the conventional technique. Thirty human premolars were divided into three groups: A (control group) - cavities were prepared with high speed and etched with 37% orthophosphoric acid; group B - cavities were prepared with Er:YAG (350 mJ, 4 Hz and 112 J /cm 2 ) and etched with 37% orthophosphoric acid; group C - cavities were prepared with Er:YAG laser (350 mJ, 4 Hz and 112 J/cm 2 ), and etched with Er:YAG laser (80 mJ, 4 Hz and 25 m/cm 2 ). All cavities were treated with the same adhesive system and restored with flow composite according to manufacturer instructions. Teeth were submitted to thermal cycling procedures and immersed in 50% Silver Nitrate Solutions for 8 hours in total darkness. Teeth were sectioned longitudinally in the bucco-lingual direction, in slices of 1 mm thick. Each slice was immersed into photo developing solution under 16 hours of fluorescent light. Slices were photographed and microleakage was scored from 0 to 7 J by three standard examiners. Results showed statistically significant differences for group C (Er:YAG laser preparation and etching). We concluded that Er:YAG laser can be used for cavity preparation of occlusal sealing, like the conventional high speed method. However, this laser, used as enamel etching agent, could not promote an adequate surface for adhesive procedures. (author)

  15. Thermally stimulated luminescence and persistent luminescence of β-irradiated YAG:Pr"3"+ nanophosphors produced by combustion synthesis

    International Nuclear Information System (INIS)

    Santacruz-Gomez, K.; Meléndrez, R.; Gil-Tolano, M.I.; Jimenez, J.A.; Makale, M.T.; Barboza-Flores, M.; Castaneda, B.; Soto-Puebla, D.; Pedroza-Montero, M.; McKittrick, J.; Hirata, G.A.

    2016-01-01

    In this work, the thermally stimulated luminescence (TSL) and persistent luminescence (PLUM) properties of praseodymium doped yttrium aluminum garnet (YAG:Pr"3"+) exposed to β-irradiation are reported. X-ray diffraction (XRD) confirms a single phase of YAG obtained by the combustion method. Transmission electron microscopy (TEM) shows that powder particles appear to be irregular crystals with an average size of 67 nm. TSL glow-curve deconvolution of YAG:Pr"3"+ after β-irradiation consist in six peaks centered at 394, 450, 467, 543, 637 and 705 K. The TSL fading and PLUM signals were found to be associated with at least with two different kinds of traps, corresponding to the peaks located at 394, 450 and 467 K. YAG:Pr"3"+ nanophosphors analyzed in this work showed interesting features about the dosimetric sensitivity as well as the reproducibility for both TSL/PLUM techniques, with good linearity dose response. These results indicate that nanocrystalline YAG:Pr3"+ is a good candidate for dosimetric applications in the range of 80 mGy-20 Gy. - Highlights: • β-irradiated YAG:Pr"3"+ TSL consist in 394, 450, 467, 543, 637 and 705 K peaks. • YAG:Pr"3"+ is a good candidate for dosimetry in the range of 80 mGy-20 Gy. • PLUM can be potentially used for in vivo, in situ and quasi in real time dosimetry.

  16. Comparative study of excimer and erbium:YAG lasers for ablation of structural components of the knee

    Science.gov (United States)

    Vari, Sandor G.; Shi, Wei-Qiang; van der Veen, Maurits J.; Fishbein, Michael C.; Miller, J. M.; Papaioannou, Thanassis; Grundfest, Warren S.

    1991-05-01

    This study was designed to compare the efficiency and thermal effect of a 135 ns pulsed-stretched XeCl excimer laser (308 nm) and a free-running Erbium:YAG laser (2940 nm) with 200 microsecond(s) pulse duration for ablation of knee joint structures (hyaline and fibrous cartilage, tendon and bone). The radiant exposure used for tissue ablation ranged from 2 to 15 J/cm2 for the XeCl excimer and from 33 to 120 J/cm2 for Er:YAG. The excimer and Er:YAG lasers were operated at 4 and 5 Hz respectively. The ablative laser energy was delivered to tissue through fibers. Ablation rates of soft tissues (hyaline and fibrous cartilage, tendon) varied from 8.5 to 203 micrometers /pulse for excimer and from 8.2 to 273 micrometers /pulse for Er:YAG lasers. Ablation rates of soft tissues are linearly dependent on the radiant exposure. Within the range of parameters tested all the tissues except the bone could be rapidly ablated by both lasers. Bone ablation was much less efficient, requiring 15 J/cm2 and 110 J/cm2 radiant exposure for excimer and Er:YAG lasers to ablate 9.5 and 8.2 micrometers tissue per pulse. However, excimer laser ablation produced less thermal damage in the tissues studied compared to Er:YAG at the same laser parameters. The authors conclude that both lasers are capable of efficient knee joint tissue ablation. XeCl excimer laser requires an order of magnitude less energy than Er:YAG laser for comparable tissue ablation.

  17. Prolonged triglyceride storage in macrophages: pHo trumps pO2 and TLR4.

    Science.gov (United States)

    Lu, Mingfang; Kho, Terry; Munford, Robert S

    2014-08-01

    Lipid-laden macrophages contribute to pathologies as diverse as atherosclerosis and tuberculosis. Three common stimuli are known to promote macrophage lipid storage: low tissue oxygen tension (pO2), low extracellular pH (pHo), and exposure to agonists such as bacterial LPS. Noting that cells responding to low pO2 or agonistic bacterial molecules often decrease pHo by secreting lactic and other carboxylic acids, we studied how pHo influences the stimulation of triacylglycerol (TAG) storage by low pO2 and LPS. We found that TAG retention after incubation for 48-72 h was inversely related to pHo when primary macrophages were cultured in 21% oxygen, 4% oxygen, or with LPS at either oxygen concentration. Maintaining pHo at ~7.4 was sufficient to prevent the increase in prolonged TAG storage induced by either low pO2 or LPS. The strong influence of pHo on TAG retention may explain why lipid-laden macrophages are found in some tissue environments and not in others. It is also possible that other long-term cellular changes currently attributed to low pO2 or bacterial agonists may be promoted, at least in part, by the decrease in pHo that these stimuli induce.

  18. HO-1 Upregulation Attenuates Adipocyte Dysfunction, Obesity, and Isoprostane Levels in Mice Fed High Fructose Diets

    Directory of Open Access Journals (Sweden)

    Zeid Khitan

    2014-01-01

    Full Text Available Background. Fructose metabolism is an unregulated metabolic pathway and excessive fructose consumption is known to activate ROS. HO-1 is a potent antioxidant gene that plays a key role in decreasing ROS and isoprostanes. We examined whether the fructose-mediated increase in adipocyte dysfunction involves an increase in isoprostanes and that pharmacological induction of HO-1 would decrease both isoprostane levels and adipogenesis. Methods and Results. We examined the effect of fructose, on adipogenesis in human MSCs in the presence and absence of CoPP, an inducer of HO-1. Fructose increased adipogenesis and the number of large lipid droplets while decreasing the number of small lipid droplets (P<0.05. Levels of heme and isoprostane in fructose treated MSC-derived adipocytes were increased. CoPP reversed these effects and markedly increased HO-1 and the Wnt signaling pathway. The high fructose diet increased heme levels in adipose tissue and increased circulating isoprostane levels (P<0.05 versus control. Fructose diets decreased HO-1 and adiponectin levels in adipose tissue. Induction of HO-1 by CoPP decreased isoprostane synthesis (P<0.05 versus fructose. Conclusion. Fructose treatment resulted in increased isoprostane production and adipocyte dysfunction, which was reversed by the increased expression of HO-1.

  19. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163Ho ions

    Science.gov (United States)

    Gastaldo, L.; Ranitzsch, P. C.-O.; von Seggern, F.; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-05-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163Ho using MMCs having the radioactive 163Ho ions implanted in the absorber. The isotope 163Ho decays through electron capture to 163Dy and features the smallest known QEC value. This peculiarity makes 163Ho a very interesting candidate to investigate the value of the electron neutrino mass by the analysis of the energy spectrum. The implantation of 163Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. Moreover the performance of the detector prototype having the 163Ho ions implanted in the absorber is already close to the requirements needed for an experiment with sub-eV sensitivity to the electron neutrino mass. Based on these results, an optimized detector design for future 163Ho experiments is presented.

  20. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163Ho ions

    International Nuclear Information System (INIS)

    Gastaldo, L.; Ranitzsch, P.C.-O.; Seggern, F. von; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-01-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163 Ho using MMCs having the radioactive 163 Ho ions implanted in the absorber. The isotope 163 Ho decays through electron capture to 163 Dy and features the smallest known Q EC value. This peculiarity makes 163 Ho a very interesting candidate to investigate the value of the electron neutrino mass by the analysis of the energy spectrum. The implantation of 163 Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. Moreover the performance of the detector prototype having the 163 Ho ions implanted in the absorber is already close to the requirements needed for an experiment with sub-eV sensitivity to the electron neutrino mass. Based on these results, an optimized detector design for future 163 Ho experiments is presented