WorldWideScience

Sample records for yonggwang unit 4-final

  1. Evaluation of Yonggwang unit 4 cycle 5 using SPNOVA code

    International Nuclear Information System (INIS)

    Choi, Y. S.; Cha, K. H.; Lee, E. K.; Park, M. K.

    2004-01-01

    Core follow calculation of Yonggwang (YGN) unit 4 cycle 5 is performed to evaluate SPNOVA code if it can be applicable or not to Korean standard nuclear power plant (KSNP). SPNOVA code consists of BEPREPN and ANC code to represent incore detector and neutronics model, respectively. SPNOVA core deflection model is compared and verified with ANC depletion results in terms of critical boron concentration (CBC), peaking factor (Fq) and radial power distribution. In YGN4, SPNOVA predicts 30 ppm lower than that of ROCS predicting CBC. Fq and radial power distribution behavior of SPNOVA calculation have conservatively higher than those of ROCS predicting values. And also SPNOVA predicting results are compared with measurement data from snapshot and CECOR core calculation. It is reasonable to accept SPNOVA to analyze KSNP. The model of SPNOVA for KSNP will be used to develop the brand-new incore detector of platinum and vanadium

  2. Initial startup and operations of Yonggwang Units 3 and 4

    International Nuclear Information System (INIS)

    Collier, T.J.; Chari, D.R.; Kiraly, F.

    1996-01-01

    A significant milestone in the nuclear power industry was achieved in 1995, when Yonggwang (YGN) Units 3 and 4 were accepted into in commercial operation by Korea Electric Power Corporation (KEPCO). YGN Unit 3 was accepted into commercial operation on March 31, 1995, the original date established during project initiation. YGN Unit 4 was accepted into operation on January 1, 1996, 3 months ahead of schedule. Each YGN unit produces approximately 1,050 Mwe and supplies approximately ten percent of the total electric power demand in the Republic of Korea (ROK). The overall plant efficiency is approximately 37% which is at least 1% higher than most nuclear units. Since achieving commercial operation, YGN Unit 3 has operated at essentially full power which has resulted in an annual performance rate in excess of 85%. YGN Unit 3 is the first of six pressurized water reactors which are currently under design and construction in the ROK and serves as the reference design for the Korean Standard Nuclear Power Plant program. Both YGN Units 3 and 4 include a System 800 Nuclear Steam Supply System (NSSS). The NSSS is rated at 2,815 Mwth and is the ABB-CE standard design. The design includes numerous advanced design features which enhance plant safety, performance and operability. A well executed startup test program was successfully completed on both units prior to commercial operation. A summary of the YGN NSSS design features, the startup test program and selected test results demonstrating the performance of those features are presented in this paper

  3. Analysis of radiation field distribution in Yonggwang unit 3 with MCNP code

    International Nuclear Information System (INIS)

    Lee, Cheol Woo; Ha, Wi Ho; Shin, Chang Ho; Kim, Soon Young; Kim, Jong Kyung

    2004-01-01

    Radiation field analysis is performed at the inside of the containment building of nuclear power plant(NPP) using the well-known MCNP code. The target NPP in this study is Yonggwang Unit 3 Cycle 8. In this work, whole transport calculations were done using MCNPX 2.4.0 due to the functional benefits, such as Mesh Tally, that the code provides. The neutron spectra released from the operating reactor core were firstly evaluated as a radiation source term, and then dose distributions in the work areas of the NPP were calculated

  4. Nuclear design report for Yonggwang nuclear power plant unit 2 cycle 7

    International Nuclear Information System (INIS)

    Zee, Sung Kyun; Choi, Gyoo Hwan; Lee, Ki Bog; Park, Sang Yoon

    1993-02-01

    This report presents nuclear design calculations for Cycle 7 of Yonggwang Unit 2. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 64 KOFA's enriched by nominally 3.70 w/o U235. Among the KOFA's, 40 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 7 amounts to 367 EFPD corresponding to a cycle burnup of 14770 MWD/MTU. (Author)

  5. Nuclear design report for Yonggwang nuclear power plant unit 4 cycle 2

    International Nuclear Information System (INIS)

    Park, Chan Oh; Park, Sang Yoon; Yoo, Choon Sung; Ryu, Hyo Sang; Park, Jin Ha; Cho, Young Chul; Song, Jae Woong; Lee Chung Chan.

    1996-10-01

    This report presents nuclear design calculations for Cycle 2 of Yonggwang Unit 4. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths, and operational limits. In addition, the report contains necessary data for the startup tests and for the assurance of shutdown margin during reactor operation. The reload core consists of 48 fresh KSFAs. Among the 48 fresh KSFAs, 32 fuel assemblies contain burnable poison rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 2 amounts to 275 EFPD corresponding to a cycle burnup of 10,100 MWD/MTU. (author). 31 tabs., 92 figs., 7 refs

  6. Nuclear design report for Yonggwang nuclear power plant unit 3 cycle 2

    Energy Technology Data Exchange (ETDEWEB)

    Zee, Sung Kyun; Song, Jae Woong; Song, Jae Seung; Park, Sang Yoon; Yoo, Choon Sung; Baek, Byung Chan; Ryu, Hyo Sang; Park, Jin Ha; Cho, Young Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    This report presents nuclear design calculations for Cycle 2 of Yonggwang Unit 3. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths, and operational limits. In addition, the report contains necessary data for the startup tests and for the assurance of shutdown margin during reactor operation. The reload core consists of 48 fresh Korean Standard Fuel Assemblies (KSFAs)and 129 burned KSFAs. Among the 48 fresh KSFAs, 32 fuel assemblies contain burnable poison rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 2 amounts to 276 EFPD corresponding to a cycle burnup of 10,160 MWD/MTU. 95 figs., 31 tabs., 7 refs. (Author) .new.

  7. Human Factors Evaluation of Procedures for Periodic Safety Review of Yonggwang Unit no. 1, 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, Jung Woon; Park, Jae Chang (and others)

    2006-01-15

    This report describes the results of human factors assessment on the plant operating procedures as part of Periodic Safety Review(PSR) of Yonggwang Nuclear Power Plant Unit no. 1, 2. The suitability of item and appropriateness of format and structure in the key operating procedures of nuclear power plants were investigated by the review of plant operating experiences and procedure documents, field survey, and experimental assessment on some part of procedures. A checklist was used to perform this assessment and record the review results. The reviewed procedures include EOP(Emergency Operating Procedures), GOP(General Operating Procedures), AOP(Abnormal Operating Procedures), and management procedures of some technical departments. As results of the assessments, any significant problem challenging the safety was not found on the human factors in the operating procedures. However, several small items to be changed and improved were discovered. An action plan is recommended to accommodate the suggestions and review comments. It will enhance the plant safety on the operating procedure.

  8. Qualification of McCARD/MASTER Code System for Yonggwang Unit 4

    International Nuclear Information System (INIS)

    Park, Ho Jin; Shim, Hyung Jin; Joo, Han Gyu; Kim, Chang Hyo

    2011-01-01

    Recently, we have developed the new two-step procedure based on the Monte Carlo (MC) methods. In this procedure, one can generate the few group constants including the few-group diffusion constants by the MC method augmented by the critical spectrum, which is provided by the solution to the homogeneous 0-dimensional B1 equation. In order to examine the qualification of the few-group constants generated by MC method, we combine MASTER with McCARD to form McCARD/MASTER code system for two-step core neutronics calculations. In the fictitious PWR system problems, the core design parameters calculated by the two-step McCARD/MASTER analysis agree well with those from the direct MC calculations. In this paper, a neutronic design analysis for the initial core of Yonggwang Nuclear Unit 4 (YGN4) is conducted using McCARD/MASTER two-step procedure to examine the qualification of two group constants from McCARD in terms of a real PWR core problem. To compare with the results, the nuclear design report and measured data are chosen as the reference solutions

  9. Comprehensive vibration assessment program for Yonggwang nuclear power plant unit 4

    International Nuclear Information System (INIS)

    Rhee, Hui Nam; Hwang, Jong Keun; Kim, Tae Hyung; Kim, Jung Kyu; Song, Heuy Gap; Kim, Beom Shig

    1995-01-01

    A Comprehensive Vibration Assessment Program (CVAP) has been performed for Yonggwang Nuclear Power Plant Unit 4 (YGN 4) in order to verify the structural integrity of the reactor internals for flow induced vibrations prior to commercial operation. The theoretical evidence for the structural integrity of the reactor internals and the basis for measurement and inspection are provided by the analysis. Flow induced hydraulic loads and reactor internals vibration response data were measured during pre-core hot functional testing in YGN 4 site. Also, the critical areas in the reactor internals were inspected visually to check any existence of structural abnormality before and after the pre-core hot functional testing. Then, the measured data have been analyzed and compared with the predicted data by analysis. The measured stresses are less than the predicted values and the allowable limits. It is concluded that the vibration response of the reactor internals due to the flow induced vibration under normal operation is acceptable for long term operation

  10. Uncertainly propagation analysis for Yonggwang nuclear unit 4 by McCARD/MASTER core analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ho Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Dong Hyuk; Shim, Hyung Jin; Kim, Chang Hyo [Seoul National University, Seoul (Korea, Republic of)

    2014-06-15

    This paper concerns estimating uncertainties of the core neutronics design parameters of power reactors by direct sampling method (DSM) calculations based on the two-step McCARD/MASTER design system in which McCARD is used to generate the fuel assembly (FA) homogenized few group constants (FGCs) while MASTER is used to conduct the core neutronics design computation. It presents an extended application of the uncertainty propagation analysis method originally designed for uncertainty quantification of the FA FGCs as a way to produce the covariances between the FGCs of any pair of FAs comprising the core, or the covariance matrix of the FA FGCs required for random sampling of the FA FGCs input sets into direct sampling core calculations by MASTER. For illustrative purposes, the uncertainties of core design parameters such as the effective multiplication factor (k{sub eff}), normalized FA power densities, power peaking factors, etc. for the beginning of life (BOL) core of Yonggwang nuclear unit 4 (YGN4) at the hot zero power and all rods out are estimated by the McCARD/MASTER-based DSM computations. The results are compared with those from the uncertainty propagation analysis method based on the McCARD-predicted sensitivity coefficients of nuclear design parameters and the cross section covariance data.

  11. Comparison of 2D and 3D Neutron Transport Analyses on Yonggwang Unit 3 Reactor

    International Nuclear Information System (INIS)

    Maeng, Aoung Jae; Kim, Byoung Chul; Lim, Mi Joung; Kim, Kyung Sik; Jeon, Young Kyou; Yoo, Choon Sung

    2012-01-01

    10 CFR Part 50 Appendix H requires periodical surveillance program in the reactor vessel (RV) belt line region of light water nuclear power plant to check vessel integrity resulting from the exposure to neutron irradiation and thermal environment. Exact exposure analysis of the neutron fluence based on right modeling and simulations is the most important in the evaluation. Traditional 2 dimensional (D) and 1D synthesis methodologies have been widely applied to evaluate the fast neutron (E > 1.0 MeV) fluence exposure to RV. However, 2D and 1D methodologies have not provided accurate fast neutron fluence evaluation at elevations far above or below the active core region. RAPTOR-M3G (RApid Parallel Transport Of Radiation - Multiple 3D Geometries) program for 3D geometries calculation was therefore developed both by Westinghouse Electronic Company, USA and Korea Reactor Integrity Surveillance Technology (KRIST) for the analysis of In-Vessel Surveillance Test and Ex-Vessel Neutron Dosimetry (EVND). Especially EVND which is installed at active core height between biological shielding material and concrete also evaluates axial neutron fluence by placing three dosimetries each at Top, Middle and Bottom part of the angle representing maximum neutron fluence. The EVND programs have been applied to the Korea Nuclear Plants. The objective of this study is therefore to compare the 3D and the 2D Neutron Transport Calculations and Analyses on the Yonggwang unit 3 Reactor as an example

  12. Evaluation of the control system checkout test at 100% power for Yonggwang Nuclear Power Plant Unit 3

    International Nuclear Information System (INIS)

    Kim, Shin Whan; Lee, Joo Han; Baek, Jong Man; Seo, Jong Tae; Lee, Sang Keun; Kang, In Koo; Ju, Hee Wan; Min, Kyung Soo; Kim, Byung Gon

    1995-01-01

    Control system checkout tests at various powers for Yonggwang Nuclear Power Plant Unit 3(YGN3) were performed to demonstrate the accuracies and proper performances of the control systems of the plant. Tested control systems included the feedwater control system, steam bypass control system, reactor regulation system, control element drive mechanism control system, pressurizer level control system, and pressurizer pressure control system. The measured test data during the control system checkout test at 100% power are evaluated. The test results showed that the control systems of YGN 3 properly control system was simulated by using the LTC code which is the performance analysis code for YGN 3 and 4 design. Comparisons of the predicted results with the measured data confirmed that the feedwater control system controls the steam generator level as designed

  13. Water Hammer Analysis using RELAP5/MOD 3.3 for Yonggwang Nuclear Power Unit 1 and 2 Blowdown System

    International Nuclear Information System (INIS)

    Lee, Sang Il; Kim, Hea Zoo; Chu, Jung Ho; Ahn, Se Hong; Jung, Chang Ho

    2010-01-01

    Water hammer can be defined as a rapid pressure step occurring in the liquid in a closed pipe caused by a sudden change in the liquid velocity. This pressure acts for a period which is twice the transit time of sonic wave in the pipe. Generally, water hammer can occur in any thermal-hydraulic systems like nuclear power plant and is extremely dangerous for nuclear power plant piping system since, if the pressure induced exceeds the pressure range of the pipe given by the manufacturer, it can lead to the failure of the piping system integrity. For Yonggwang nuclear power unit 1 and 2, water hammer occurred repeatedly on the outlet piping of regenerative heat exchanger of steam generator blowdown system. Thus, design modification was performed to prevent the water hammer and the analysis of effect on water hammer before and after design modification was performed to verify the validity of the design modification

  14. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  15. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  16. Human Factors Evaluation of Man-Machine Interface for Periodic Safety Review of Yonggwang Unit no. 1, 2

    International Nuclear Information System (INIS)

    Lee, Yong Hee; Lee, Jung Woon; Park, Jae Chang

    2006-01-01

    This report describes the research results of human factors assessment on the MMI(Man Machine Interface) equipment as part of Periodic Safety Review(PSR) of Yonggwang Unit no. 1, 2. As MMI is a key factor among human factors to be reviewed in PSR, we reviewed the MMI components of nuclear power plants in aspect of human factors engineering. The availability, suitability, and effectiveness of the MMI devices were chosen to be reviewed. The MMI devices were investigated through the review of design documents related to the MMI, survey of control panels, evaluation of experts, and experimental assessment. Checklists were used to perform this assessment and record the review results. The items mentioned by the expert comments to review in detail in relation with task procedures were tested by experiments with operators' participation. For some questionable issues arisen during this MMI review, operator workload and possibility of errors in operator actions were analysed. The reviewed MMI devices contain MCR(Main Control Room), SPDS(Safety Parameter Display System), RSP(Remote Shutdown Panel), and the selected LCBs(Local Control Boards) importantly related to safety. As results of the assessments, any significant problem challenging the safety was not found on human factors in the MMI devices. However, several small items to be changed and improved in suitability of MMI devices were discovered. An action plan is recommended to accommodate the suggestions and review comments. It will enhance the plant safety on MMI area

  17. Human Factors Evaluation of Man-Machine Interface for Periodic Safety Review of Yonggwang Unit no. 1, 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Lee, Jung Woon; Park, Jae Chang (and others)

    2006-01-15

    This report describes the research results of human factors assessment on the MMI(Man Machine Interface) equipment as part of Periodic Safety Review(PSR) of Yonggwang Unit no. 1, 2. As MMI is a key factor among human factors to be reviewed in PSR, we reviewed the MMI components of nuclear power plants in aspect of human factors engineering. The availability, suitability, and effectiveness of the MMI devices were chosen to be reviewed. The MMI devices were investigated through the review of design documents related to the MMI, survey of control panels, evaluation of experts, and experimental assessment. Checklists were used to perform this assessment and record the review results. The items mentioned by the expert comments to review in detail in relation with task procedures were tested by experiments with operators' participation. For some questionable issues arisen during this MMI review, operator workload and possibility of errors in operator actions were analysed. The reviewed MMI devices contain MCR(Main Control Room), SPDS(Safety Parameter Display System), RSP(Remote Shutdown Panel), and the selected LCBs(Local Control Boards) importantly related to safety. As results of the assessments, any significant problem challenging the safety was not found on human factors in the MMI devices. However, several small items to be changed and improved in suitability of MMI devices were discovered. An action plan is recommended to accommodate the suggestions and review comments. It will enhance the plant safety on MMI area.

  18. Removal of Secondary Side Deposit and Foreign Objects in SG of Yonggwang Nuclear Power Plant, Unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Wootae [KHNP-CRI, Daejeon (Korea, Republic of); Yun, Sangjung; Choi, Yongseok; Kim, Taehwa; Seo, Hongchang [Byucksan Digital Valley II, Seoul (Korea, Republic of)

    2014-05-15

    Mock-up test and training before the service were made to minimize operation time and radiation dose. 8 bag filters and 49 cartridge filters were consumed for filtering of soft and hard sludge in SG A, B, and C. Total 21.05 kilograms of sludge was removed. Five foreign objects were found and removed in tube bundle of SG A, in annulus and tube bundle of SG B, and in tube bundle of SG C. During the 20{sup th} OH of Yonggwang NPP unit 2, we removed 21.05 kilograms of sludge and five foreign objects from three steam generators. Gradual increase in weight of sludge removed is assumed to show us that more sludge is created as operation time of steam generator increases. Low level chemical cleaning at 19{sup th} OH removed 517 kilograms of sludge which was dominant of all the sludge removal weight. We could assume, from this fact, that high level chemical cleaning could remove significant amount of sludge compared to mechanical lancing method. Five foreign objects which were removed from inside of SG showed us that more thorough inside cleaning and inspection is necessary during fabrication of steam generator.

  19. Final report for the 5th surveillance test of the reactor pressure vessel material (capsule Y) of Yonggwang Nuclear Power Plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sam Lai; Kim, ByoungChul; Chang, Kee Ok (and others)

    2006-02-15

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Daejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X, W and Y are 5.777E+18, 1.5371E+19, 3.7634E+19, 4.3045E+19, and 4.8662E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.953 for the 1st through 5th testing and the calculational uncertainty,7.2% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.659E+19n/cm{sup 2} based on the end of 13th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 48, 56 and 64EFPY would reach 3.625E+19, 5.293E+19, 6.127E+19 and 6.960E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the Pressurized Thermal Shock(PTS) during the operation until design life.

  20. Evaluation of Steam Generator Level behavior for Determination of Turbine Runback rate on COPs trip for Yonggwang 1 and 2 Power Uprating Units

    International Nuclear Information System (INIS)

    Lee, Kyung Jin; Hwang, Su Hyun; Yoo, Tae Geun; Chung, Soon Il; An, Byung Chang; Park, Jung Gu

    2010-01-01

    4.5% power uprate project has been progressing for the first time in Yonggwang 1 and 2(YGN1 and 2). Reviews for design change due to the power uprate were accomplished. Steam generator level behavior was one of the most important parameters because it could be cause of reactor trip or turbine trip. As the results of the reviews, YGN1 and 2 had to reassess it for change of turbine runback rate when turbine runback occurs due to the condensate operating pumps (COP) trip. This study has been carried out for evaluating the steam generator level behavior for determination of turbine runback rate on COPs trip for Yonggwang 1 and 2 Power Uprating Units. The steam generator water level evaluation program for YGN1 and 2 (SLEP-Y1) has been developed for it. The program includes models for the steam generator water level response. SLEP-Y1 is programmed with advanced continuous system simulation language (ACSL). The language has been used to simulate physical systems as a commercial tool used to evaluate system designs

  1. Nuclear design report for Yonggwang nuclear power plant unit 1 cycle 9

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young chul; Kim, Jae Hak; Song, Jae Woong [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-03-01

    This report presents nuclear design calculations for Cycle 6 of Yonggwng Unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 4.00 w/o U{sub 235}. Among the KOFA`s, 60 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of Cycle 9 amounts to 434 EFPD corresponding to a cycle burnup of 17470 MWD/MTU. (Author) 8 refs., 55 figs., 19 tabs.

  2. Nuclear design report for Yonggwang nuclear power plant unit 1, cycle 8

    International Nuclear Information System (INIS)

    Cho, Young Chul; Kim, Jae Hak; Park, Sang Yoon; Zee, Sung Kyun; Lee, Sang Keun; Ahn, Dawk Hwan

    1993-10-01

    This report presents nuclear design calculations for cycle 8 of Kori unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA's enriched by nominally 3.70 w/o U 235 . Among the KOFA's, 56 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 8 amounts to 447 EFPD corresponding to a cycle burnup of 18020 MWD/MTU. (Author) 8 refs., 39 figs., 17 tabs

  3. Nuclear design report for Yonggwang nuclear power plant unit 1, cycle 8

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Chul; Kim, Jae Hak; Park, Sang Yoon; Zee, Sung Kyun; Lee, Sang Keun; Ahn, Dawk Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1993-10-01

    This report presents nuclear design calculations for cycle 8 of Kori unit 1. Information is given on fuel loading, power density distributions, reactivity coefficients, control rod worths and operational limits. In addition, the report contains all necessary data for the startup tests including predicted values for the comparison with the measured data. The reload consists of 76 KOFA`s enriched by nominally 3.70 w/o U{sub 235}. Among the KOFA`s, 56 fuel assemblies contain gadolinia rods. The fuel assemblies in the core are arranged in a low leakage loading pattern. The cycle length of cycle 8 amounts to 447 EFPD corresponding to a cycle burnup of 18020 MWD/MTU. (Author) 8 refs., 39 figs., 17 tabs.

  4. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Yonggwang nuclear power plant unit 2

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-02-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.762E+18, 1.5391E+19, 3.5119E+19, and 4.2610E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.899 for the 1st through 4th testing and the calculational uncertainty, 12.3% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.357E+19 n/cm{sup 2} based on the end of 11th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.525E+19, 4.337E+19, 5.148E+19 and 5.960E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 42 tabs. (Author)

  5. A flow test for calibrating 177 core tubes of 1/5-scale reactor flow model for Yonggwang nuclear units 3 and 4

    International Nuclear Information System (INIS)

    Lee, Byung Jin; Jang, Ho Cheol; Cheong, Jong Sik; Kuh, Jung Eui

    1990-01-01

    A flow test was performed to find out the hydraulic characteristics of every one of 177 core tubes, representing a fuel assembly respectively, as a preparatory step of 1/5 scale reactor flow model test for Yonggwang Nuclear Units (hereafter YGN) 3 and 4. The axial hydraulic resistance of the fuel assembly was simulated in the square core tube with six orifice plates positioned along the tube length; core support structure below each fuel assembly was done in the core upstream geometry section of the test loop. For each core tube the pressure differentials across the inlet, exit orifice plate and overall tube length were measured, along with the flow rates and temperatures of the test fluid. The measured pressure drops were converted to pressure loss or flow metering coefficients. The metering coefficient of the inlet orifice plate was sensitive to the configuration and location of the upstream geometry. The hydraulic resistance of the core tubes were reasonably coincided with a target value and consistent. The polynomial curve fits of the calibrated coefficients for the 177 core tubes were obtained with reasonable data scatters

  6. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  7. Natural circulation cooldown analysis for Yonggwang 3 and 4 per US NRC BTP RSB 5-1 requirements

    International Nuclear Information System (INIS)

    Seo, J.T.; Ko, C.S.; Ro, T.S.; Simoni, L.P.

    2004-01-01

    The Natural Circulation Cooldown (NCC) analysis from normal operations to shutdown cooling entry conditions for Yonggwang units 3 and 4 (YGN 3 and 4) was performed within the requirements of U.S. Nuclear Regulatory Commission (NRC) Branch Technical Position (BTP) RSB 5-1. The results showed that the YGN 3 and 4 can be cooled and depressurized to the shutdown entry conditions (350 deg F, 410 psia) within 16 hours under natural circulation condition requiring only 78% of the minimum condensate water storage capacity in conformance with BTP RSB 5-1 requirements. The results also demonstrated that the safety grade Reactor Coolant Gas Vent System (RCGVS) has sufficient capacity for the RCS depressurization as well as for the steam void control in the reactor vessel upper head region. (author)

  8. The contract of design of an atomic reactor system in Yonggwang - 5, 6 nuclear power plant

    International Nuclear Information System (INIS)

    1995-05-01

    This is a contract of design of an atomic reactor system in Yonggwang 5, 6 nuclear power plant. It has the general contract condition. In the appendix, it indicates the detail regulations between two parties which are the coverage of division on the responsibility, schedule of the delivery, standard of the technology, guarantee, drawing and paper support of the Korea Electric Power Corporation, support of technology drill, test, regulations of code and standard and list of items and prices.

  9. Tube Plugging Criterion for the TPCCW Heat Exchanger of Yonggwang NPP 1 and 2

    International Nuclear Information System (INIS)

    Kim, Hyung Nam; Yoo, Hyun Ju; Choi, Sung Nam; Song, Seok Yoon

    2009-01-01

    The turbine plant component cooling water(TPCCW) system circulates the cooling water to cool the components in the turbine building and discharges the heat from the components through the TPCCW heat exchanger. Recently, Yonggwang NPP 1 and 2 replaced the TPCCW heat exchanger because of tube degradation. The tubing material of new TPCCW heat exchanger of Yonggwang NPP 1 and 2 is titanium. If the tube wall cannot withstand the pressure, the cooling water with the chemicals flows into the tube side and it is discharged to the open water. The chemicals can pollute the open water. Therefore, the tubes of the TPCCW heat exchanger should be inspected and degraded tubes should be plugged. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. However, tubes have experienced leaks and failures and plugged based upon eddy current testing (ET) results. There are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. For this reason, the criteria for the tube wall thickness are addressed in order to operate the heat exchangers in nuclear power plant without trouble during the cycle. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. This method relies on the similar plugging criteria used in the steam generator

  10. Tube Plugging Criterion for the TPCCW Heat Exchanger of Yonggwang NPP 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Nam; Yoo, Hyun Ju; Choi, Sung Nam; Song, Seok Yoon [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The turbine plant component cooling water(TPCCW) system circulates the cooling water to cool the components in the turbine building and discharges the heat from the components through the TPCCW heat exchanger. Recently, Yonggwang NPP 1 and 2 replaced the TPCCW heat exchanger because of tube degradation. The tubing material of new TPCCW heat exchanger of Yonggwang NPP 1 and 2 is titanium. If the tube wall cannot withstand the pressure, the cooling water with the chemicals flows into the tube side and it is discharged to the open water. The chemicals can pollute the open water. Therefore, the tubes of the TPCCW heat exchanger should be inspected and degraded tubes should be plugged. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. However, tubes have experienced leaks and failures and plugged based upon eddy current testing (ET) results. There are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. For this reason, the criteria for the tube wall thickness are addressed in order to operate the heat exchangers in nuclear power plant without trouble during the cycle. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. This method relies on the similar plugging criteria used in the steam generator

  11. Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants

    International Nuclear Information System (INIS)

    Na, Man Gyun; Sim, Young Rok; Jung, Chul Kee; Lee, Goung Jin; Kim, Soong Pyung; Chung, Sung Tai

    2000-01-01

    XOQ DW code is currently used to assess the atmospheric dispersion for the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion for the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ DW code inputs and the relative concentrations (X/Q) of XOQ DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as 1.33 x 10 -4 and 7.66 x 10 -6 sec/m 3 , respectively. Through the development of this code, a code system is prepared for assessing the atmospheric dispersion for the accidental releases as well as the routine releases. This developed code can be used for other domestic nuclear power plants by modifying the terrain input data

  12. Reload safety evaluation report for Yonggwang nuclear power plant unit 1, cycle 8

    International Nuclear Information System (INIS)

    Lee, Won Jae; Yoon, Kyung Ho; Cho, Young Chul; Kim, Jae Hak; Um, Kil Sup; Choi, Han Rim; Kim, Ki Hang; Sung, Kang Sik

    1993-09-01

    This report presents a reload safety evaluation for YGN-1, cycle 8 and demonstrates that the core being entirely composed of KOFA as described in the report will not adversely affect the safety of the public and the plant. All of the accidents comprising the licensing bases which could potentially be affected by the fuel reload have been reviewed for the cycle 8 core and results are described in the report. (Author) 1 ref., 4 figs., 5 tabs

  13. Reload safety evaluation report for yonggwang nuclear power plant unit 2 cycle 7

    International Nuclear Information System (INIS)

    Zee, Sung Kyun; Choi, Gyoo Hwan; Lee, Ki Bog; Park, Sang Yoon

    1993-01-01

    This report presents the reload safety evaluation for YGN-2, Cycle 7 and demonstrates that the reactor core being entirely composed of KOFA as described below will not adversely affect the safety of the public and the plant. All of the accidents comprising the licensing bases which would potentially be affected by the reload fuel assemblies have been reviewed for the Cycle 7 core design described herein. (Author)

  14. Reload safety evaluation report for yonggwang nuclear power plant unit 1 cycle 7

    International Nuclear Information System (INIS)

    Park, Chan Oh; Kwon, Tae Je; Park, Sang Yoon; Sung, Kang Sik; Kim, Ki Hang; Yim, Jeong Sik; Kim, Du Ill; Choi, Han Rim; Bae, Hoo Gun

    1992-06-01

    This report presents the reload safety evaluation for YGN-1, Cycle 7 and demonstrates that the reactor core being entirely composed of KOFA as discribed below will not adversely affect the safety of the public and the plant. All of the accidents comprising the licensing bases which could potentially be affected by the reload fuel assemblies have been reviewed for the Cycle 7 core and results are described in this report. (Author)

  15. Reload safety evaluation report for Yonggwang nuclear power plant unit 1, cycle 9

    International Nuclear Information System (INIS)

    Cho, Young Chul; Nam, Kee Il; Kim, Ki Hang; Suh, Jung Min; Um, Kil Sup; Ban, Chang Hwan; Bae, Hoo Gun

    1995-02-01

    This report presents a reload safety evaluation for YGN-1, Cycle 9 and demonstrates that the core being entirely composed of KOFA as described in the report will not adversely affect the safety of the public and the plant. All of the accidents comprising the licensing bases which could potentially be affected by the fuel reload have been reviewed for the Cycle 9 core and results are described in this report. (Author) 1 refs., 3 figs., 6 tabs

  16. A stochastic assessment of cavity flooding strategy involving operator action for Yonggwang 3 and 4 units

    International Nuclear Information System (INIS)

    Kim, J.; Yu, D.; Ha, J.

    1997-01-01

    The author presents a new approach to the evaluation of an accident management strategy when an operator action is involved. This approach classifies the failure in implementing a given strategy into 4 possible states, and provides their corresponding quantification methods: 1) the failure of a diagnosis and decision-making by operators, 2) the failure of taking an action following a correct diagnosis, 3) the failure of a system operation following an adequate action, and 4) the failure due to a delayed action. The proposed methods were applied to assess a cavity flooding strategy that uses containment spray system (CSS), and the result shows that the methods are more appropriate in evaluating accident management strategies when human actions are involved

  17. The assessment of health effect of Yonggwang site using the MACCS code

    International Nuclear Information System (INIS)

    Jeong, Dognhan Yu; Kim, Seiung Hwan; Han, Byoung Sub; Song, Jong Soon

    1996-12-01

    The health effect assessment near the Yonggwang site by using IPE results and its site data was performed. The health effect assessment is an important part of consequence analysis of a nuclear power plant site. The MACCS code developed by SNL was used in the assessment. The necessary input data are source term data, meteorological data, population data, and detailed information about the release of radionuclides. The core inventory data for end-of-cycle are calculated by ORIGEN2 code for conservatism because fission product buildup is greatest at end-of-cycle conditions. Meteorological and population data was derived from the FSAR and environmental impact statement report, and source term release data was derived from the IPE report. by using the MACCS code, the CCDF is obtained as a result and economic impact analysis is also possible. First of all, the average value of early fatality was estimated by changing the initial value of random numbers. The average value obtained from 10 trials is in the rage between 10 -4 and 10 -3 and have a log-uniform distribution. More than 10 data are necessary in order to have a meaningful value statistically. And the calculations about early fatality, early injury, risks of early fatality, population dose within 16.0km, population risk for early fatality within 8.0km are performed. In all cases, STC-3 is the dominant contributor (about 70%), and STC-14 is the next important contributor. Therefore, in case of consequence analysis resulting from internal events, the analysis based on STC-3 which is the failure of early containment isolation is very important. Based on the calculation of CCDF for each risk measure, it is shown that CCDF has a slow slope and thus wide probability distribution in cases of early fatality, early injury, total early fatality risk, and total weighted early fatality risk, And in cases of cancer fatality and population dose within 48 km and 80km, the CCDF curve have a steep slope and thus narrow

  18. New off-road engines for TIER 4 final; Neue Offroad-Motoren fuer Tier 4 final

    Energy Technology Data Exchange (ETDEWEB)

    Adt, Hans-Ulrich; Lehmann, Henrik [MTU Friedrichshafen GmbH, Friedrichshafen (Germany); Herter, Yvonne; Weidler, Alexander [Daimler AG, Stuttgart (Germany). Baureihe 1000

    2013-03-15

    To meet the off-road emission standards EU IV and EPA Tier 4 final, as of 2014 the Tognum Group will be offering newly developed engines of the Series 1000 to 1500. These MTU brand diesel engines deliver outputs ranging from 100 to 460 kW and are designed to power agricultural and forestry machinery and construction as well as special-purpose machinery. (orig.)

  19. The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang No 3 and 4 and No 5 and 6

    International Nuclear Information System (INIS)

    Yeom, Yu Sun; Kim, Soong Pyung; Lee, Seung Jin

    2004-01-01

    Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontamination ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP No 5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473 mCi and 1.098 mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was 2.97 x 10 -6 mSv for the evaporating system, and 6.47 x 10 -6 mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  20. The Comparison on Treatment Method of Liquid Radioactive Waste in Yonggwang No 3 and 4 and No 5 and 6

    Energy Technology Data Exchange (ETDEWEB)

    Yeom, Yu Sun; Kim, Soong Pyung [Chosun University, Gwangju (Korea, Republic of); Lee, Seung Jin [RedTek CO., LTD., Daejeon (Korea, Republic of)

    2004-09-15

    Most of the low-level liquid radioactive wastes generated from PWR plants are classified into high or low total suspended solid(HTDS or LTDS), and into radiochemical and radioactive laundry waste. Although the evaporation process has a high decontamination ability, it has several problems such as corrosion, foam, and congestion. A new liquid waste disposal process using the ion-exchange demineralizer(IED), instead of the current evaporation process, has been introduced into the Yonggwang NPP No 5 and 6. These two methods have been compared to understand the differences in this study. Aspects compared here were the released radioactivity amount of the liquid radioactive wastes, the dose of off-site residents, the decontamination factor, and the amount of the solid radioactive wastes. The IED system is designed to discharge higher radioactivity about 20% than the evaporating system, and the actual radioactivity released from the evaporating and IED system were 0.473 mCi and 1.098 mCi, respectively. The radioactivity released from the IED was 2.32 times higher than that of the evaporating system. The dose of off-site residents was 2.97 x 10{sup -6} mSv for the evaporating system, and 6.47 x 10{sup -6} mSv for IED. The decontamination factor(DF) of the evaporator is, in most cases, far lower than the lower limits of detection(LLD) with the Ge-Li detector. Due to the low concentration of the liquid wastes collected from the liquid waste system, the decontamination factor of IED is very low. Since there is not enough data on the amount of solid radioactive wastes generated by the evaporation system, the comparison on these two systems has been conducted on the basis of the design, and the comparison result was that the evaporating system generated more wastes about 40% than IED.

  1. A Study on Performance Evaluation of Safety-Related Protective Coating for Yonggwang Unit 1 and 2

    International Nuclear Information System (INIS)

    Kim, Sung Young; Kim, Young Bum; Lee, Won Sang

    2010-01-01

    Protective coating inside nuclear power plants could find its origin from NRC Reg. Guide 1.82(Rev. 3) regarding current issue for the regulation of foreign materials inside containment building. The current issue for the regulation of foreign materials inside containment considered/determined the current issues only regarding the blockage of sump screen by foreign materials such as coating material, insulator, and other materials, while safety-related coating is separately managed by NRC Reg. Guide 1.54(Rev. 1). In this study, we performed field walk-down to evaluate the as-is condition of protective coating inside containment building which was classified as for structure and for equipment with applying the requirement for safety-related coating

  2. A feasibility study on the longer cycle operation of Yonggwang nuclear power plants 3 and 4 NSSS design

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Young Joon; Choi, Hae Yoon; Chang, Young Woo [Korea Atomic Energy Research Inst., Daeduk (Korea, Republic of)] [and others

    1996-06-01

    A feasible study on the NSSS design safety assessment is performed for a longer cycle operation of Yonggang units 3 and 4. The analysis of the drift errors increased and setting point changed for safety related instrument channels due to the longer refueling interval was done to assess the impact on the operational safety performance and availability of the plant if the refueling interval was extended. In the result of LOCA analysis, even though the Peak Cladding Temperature (PCT) is slightly increased due to Pin/Box ratio decrease, the PCT has enough margin and, therefore, it was proven to be acceptable. From the perspective of return-to-power and the pre-trip fuel performance during the transient operation, an impact on the results of an SLB accident analysis were assessed. The overall trend of the longer refueling operation of 18 months is similar to the standard refuel operation of 12 months. The possibility of the return to power during SLB accident condition was estimated, the detailed analysis of the reactor core using the 3-dimensional model methodology is required to confirm the fuel integrity. 11 refs.(Author) .new.

  3. Improvement of risk informed surveillance test interval for the safety related instrumentation and control system of Yonggwang units 3 and 4

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Lee, Yun Hwan; Lee, Seung Joon; Han, Sang Hoon

    2012-05-01

    The purpose of this research is the development of various methodologies necessary for the licensing of the risk informed surveillance test interval(STI) improvement for the safety related I and C systems in YGN 3 and 4, for instance, reactor protection system (RPS), engineered safety features actuation system (ESFAS), ESF auxiliary relay cabinet (ARC), and core protection calculator (CPC). The technical adequacy of the methodology was sufficiently verified through the application to the following STI changes. o CPC channel functional test (change from 1 month to 3 months including safety channel and log power test) o RPS channel functional test (change from 1 month to 3 months) o RPS logic and trip channel test (change from 1 month to 3 months. 1 month for RPS manual actuation test) o ESFAS channel functional test (change from 1 month to 3 months) o ESFAS logic and trip channel test (change from 1 month to 3 months) o ESF auxiliary relay test (change from 1 month to 3 months with staggered test. Manual actuation at the ESF ARC is added as a backup of ESF actuation signals during emergency operation

  4. Analysis of Gamma Dose Rate Caused by Corrosion Products inside the Containment Building of Yonngwang Nuclear Power Plant Unit 3 During Shutdown Period

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Wi Ho; Kim, Jae Cheon; Kim, Soon Young; Kim, Jong Kyung [Hanyang Univ., Seoul (Korea, Republic of)

    2005-07-01

    Occupational radiation exposure(ORE) of nuclear power plant(NPP) workers mainly occurs during the shutdown period. Major radioactive sources are the corrosion products released from the reactor coolant system(RCS). The corrosion products consist of circulating crud and deposited crud. Major radioactive corrosion products, {sup 58}Co and {sup 60}Co, are known to contribute approximately more than 70% of the total ORE. In this study, the corrosion products regarding cobalt were evaluated during the shutdown period, and gamma dose rates caused by them were calculated at the main working area inside the containment building of the Yonggwang NPP Unit 3.

  5. The 4th surveillance test and evaluation of the reactor pressure vessel material (capsule W) of Younggwang nuclear power plant unit1

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Yonggwang site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Yonggwang unit 1 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 5.555E+18, 1.662E+19, 3.358E+19, and 4.521E+19 n/cm{sup 2}, respectively. The bias factor, the ratio of measurement versus calculation, was 0.859 for the 1st through 4th testing and the calculational uncertainty, 11.80% satisfied the requirement of USNRC Reg.Guide 1.190, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.551E+19 n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.929E+19, 4.880E+19, 5.831E+19 and 6.782E+19 n/cm{sup 2} based on the current calculation. The result through this analysis for Yonggwang unit 1 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 4 refs., 41 figs., 35 tabs. (Author)

  6. Development of Thermal Performance Analysis Computer Program on Turbine Cycle of Yoggwang 3,4 Units

    Energy Technology Data Exchange (ETDEWEB)

    Hong, S.Y.; Choi, K.H.; Jee, M.H.; Chung, S.I. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    The objective of the study ''Development of Thermal Performance Analysis Computer Program on Turbine Cycle of Yonggwang 3,4 Units'' is to utilize computerized program to the performance test of the turbine cycle or the analysis of the operational status of the thermal plants. In addition, the result can be applicable to the analysis of the thermal output at the abnormal status and be a powerful tool to find out the main problems for such cases. As a results, the output of this study can supply the way to confirm the technical capability to operate the plants efficiently and to obtain the economic gains remarkably. (author). 27 refs., 73 figs., 6 tabs.

  7. Software development for simplified performance tests and weekly performance check in Younggwang NPP Unit 3 and 4

    International Nuclear Information System (INIS)

    Hur, K. Y.; Jang, S. H.; Lee, J. W.; Kim, J. T.; Park, J. C.

    2002-01-01

    This paper covers the current status of turbine cycle performance test in nuclear power plants and the software development which can solve some shortcomings related to performance tests. The software developed is for simplified performance tests and weekly performance checks in Yonggwang nuclear power plant unit 3 and 4. This software includes the requirements from the efficiency division for the consistency with actual performance analysis work and the usability of the collected performance test data. From the working survey, we identify the difference between the embedded performance analysis modules and the actual performance analysis work. This software helps operation or maintenance personnel to reduce work load, to support the trend analysis of essential parameters in a turbine cycle, and to utilize the correction curves for the decision-making in their work

  8. Workstation environment supports for startup of YGN 3 and 4 nuclear unit

    International Nuclear Information System (INIS)

    Lee, Won Jae; Kim, Won Bong; Lee, Byung Chae

    1995-07-01

    Light water reactor fuel development division of Korea Atomic Energy Research Institute participated in the installation of the plant computer system and software, and the user support activities of Asea Brown Boveri/Combustion Engineering for the Plant Monitoring System during the startup phase of YGN-3 nuclear unit. The main purpose of the participation is to have the self-reliant plant- computer technology for the independent design and startup of next nuclear units. This report describes the activities performed by KAERI with ABB/CE at the plant site. In addition, it describes the direct transfer of data files between PMS and workstation which was independently carried out by KAERI. Since KAERI should support the site in setting-up the plant computer environment independent of ABB-CE from the next nuclear units, the review was performed for the technical details of activities provided to the site in order to provide the better computer environment in the next nuclear units. In conclusion, this report is expected to provide the technical background for the supporting of plant computing environment and the scope of support work at plant site during Yonggwang 3, 4 startup in the area of plant computer for the next nuclear units. 6 refs. (Author) .new

  9. Workstation environment supports for startup of YGN 3 and 4 nuclear unit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jae; Kim, Won Bong; Lee, Byung Chae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    Light water reactor fuel development division of Korea Atomic Energy Research Institute participated in the installation of the plant computer system and software, and the user support activities of Asea Brown Boveri/Combustion Engineering for the Plant Monitoring System during the startup phase of YGN-3 nuclear unit. The main purpose of the participation is to have the self-reliant plant- computer technology for the independent design and startup of next nuclear units. This report describes the activities performed by KAERI with ABB/CE at the plant site. In addition, it describes the direct transfer of data files between PMS and workstation which was independently carried out by KAERI. Since KAERI should support the site in setting-up the plant computer environment independent of ABB-CE from the next nuclear units, the review was performed for the technical details of activities provided to the site in order to provide the better computer environment in the next nuclear units. In conclusion, this report is expected to provide the technical background for the supporting of plant computing environment and the scope of support work at plant site during Yonggwang 3, 4 startup in the area of plant computer for the next nuclear units. 6 refs. (Author) .new.

  10. RCGVS design improvement and depressurization capability tests for Ulchin nuclear power plant units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kang Sik; Seong, Ho Je; Jeong, Won Sang; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Lim, Keun Hyo; Choi, Kwon Sik; Oh, Chul Sung [Korea Electric Power Cooperation, Taejon (Korea, Republic of)

    1999-12-31

    The Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4) has been improved from the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3 and 4) based on the evaluation results for depressurization capability tests performed at YGN 3 and 4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown phenomena in order to optimize the orifice size of UCN 3 and 4 RCGVS. Based on these analyses results, the RCGVS orifics size for UCN 3 and 4 has been reduced to 9/32 inch from the 11/32 inch for YGN 3 and 4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3 and 4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation. 6 refs., 5 figs., 1 tab. (Author)

  11. RCGVS design improvement and depressurization capability tests for Ulchin nuclear power plant units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Kang Sik; Seong, Ho Je; Jeong, Won Sang; Seo, Jong Tae; Lee, Sang Keun [Korea Power Engineering Company, Inc., Seoul (Korea, Republic of); Lim, Keun Hyo; Choi, Kwon Sik; Oh, Chul Sung [Korea Electric Power Cooperation, Taejon (Korea, Republic of)

    1998-12-31

    The Reactor Coolant Gas Vent System(RCGVS) design for Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4) has been improved from the Yonggwang Nuclear Power Plant Units 3 and 4 (YGN 3 and 4) based on the evaluation results for depressurization capability tests performed at YGN 3 and 4. There has been a series of plant safety analyses for Natural Circulation Cooldown(NCC) event and thermo-dynamic analyses with RELAP5 code for the steam blowdown phenomena in order to optimize the orifice size of UCN 3 and 4 RCGVS. Based on these analyses results, the RCGVS orifics size for UCN 3 and 4 has been reduced to 9/32 inch from the 11/32 inch for YGN 3 and 4. The depressurization capability tests, which were performed at UCN 3 in order to verify the FSAR NCC analysis results, show that the RCGVS depressurization rates are being within the acceptable ranges. Therefore, it is concluded that the orificed flow path of UCN 3 and 4 RCGVS is adequately designed, and can provide the safety-grade depressurization capability required for a safe plant operation. 6 refs., 5 figs., 1 tab. (Author)

  12. Development of the NSSS thermal-hydraulic program for YGN unit 1 simulator

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Doo; Jeong, Jae Jun; Lee, Won Jae; Chung, Bub Dong; Ha, Kwi Seok; Kang, Kyung Ho

    2000-09-01

    The NSSS thermal-hydraulic programs installed in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited computational capability at that time, they usually adopt very simplified physical models for a real-time simulation of NSSS thermal-hydraulic phenomena, which entails inaccurate results and the possibility of so-called 'negative training', especially for complicated two-phase flows in the reactor coolant system. To resolve the problem, we developed a realistic NSSS T/H program (named 'ARTS' code) for use in YongGwang Nuclear Unit 1 full-scope simulator. The best-estimate code RETRAN03, developed by EPRI and approved by USNRC, was selected as a reference code of ARTS. For the development of ARTS, the followings have been performed: -Improvement of the robustness of RETRAN - Improvement of the real-time simulation capability of RETRAN - Optimum input data generation for the NSSS simulation - New model development that cannot be efficiently modeled by RETRAN - Assessment of the ARTS code. The systematic assessment of ARTS has been conducted in both personal computers (Windows 98, Visual fortran) and the simulator development environment (Windows NT, GSE simulator development tool). The results were resonable in terms of accuracy, real-time simulation and robustness.

  13. Development of the NSSS thermal-hydraulic program for YGN unit 1 simulator

    International Nuclear Information System (INIS)

    Kim, Kyung Doo; Jeong, Jae Jun; Lee, Won Jae; Chung, Bub Dong; Ha, Kwi Seok; Kang, Kyung Ho

    2000-09-01

    The NSSS thermal-hydraulic programs installed in the domestic full-scope power plant simulators were provided in early 1980s by foreign vendors. Because of limited computational capability at that time, they usually adopt very simplified physical models for a real-time simulation of NSSS thermal-hydraulic phenomena, which entails inaccurate results and the possibility of so-called 'negative training', especially for complicated two-phase flows in the reactor coolant system. To resolve the problem, we developed a realistic NSSS T/H program (named 'ARTS' code) for use in YongGwang Nuclear Unit 1 full-scope simulator. The best-estimate code RETRAN03, developed by EPRI and approved by USNRC, was selected as a reference code of ARTS. For the development of ARTS, the followings have been performed: -Improvement of the robustness of RETRAN - Improvement of the real-time simulation capability of RETRAN - Optimum input data generation for the NSSS simulation - New model development that cannot be efficiently modeled by RETRAN - Assessment of the ARTS code. The systematic assessment of ARTS has been conducted in both personal computers (Windows 98, Visual fortran) and the simulator development environment (Windows NT, GSE simulator development tool). The results were resonable in terms of accuracy, real-time simulation and robustness

  14. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  15. Generating Units

    Data.gov (United States)

    Department of Homeland Security — Generating Units are any combination of physically connected generators, reactors, boilers, combustion turbines, and other prime movers operated together to produce...

  16. Unit Manning

    National Research Council Canada - National Science Library

    McGinniss, Mike

    2003-01-01

    .... This decision combines two crucial initiatives: first, transforming the Army from an individual soldier replacement system to a unit manning system that enhances cohesion and keeps trained soldiers, leaders, and commanders together longer, thereby...

  17. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  18. Drilling unit

    Energy Technology Data Exchange (ETDEWEB)

    Umanchik, N P; Demin, A V; Khrustalev, N N; Linnik, G N; Lovchev, S V; Rozin, M M; Sidorov, R V; Sokolov, S I; Tsaregradskiy, Yu P

    1981-01-01

    A drilling unit is proposed which includes a hydraulic lifter, hydraulic multiple-cylinder pump with valve distribution and sectional drilling pump with separators of the working and flushing fluid. In order to reduce metal consumption and the overall dimensions of the drilling unit, the working cavity of each cylinder of the hydraulic multiple-cylinder pump is equipped with suction and injection valves and is hydraulically connected to the working cavity by one of the sections of the drilling pump.

  19. [Conservation Units.

    Science.gov (United States)

    Texas Education Agency, Austin.

    Each of the six instructional units deals with one aspect of conservation: forests, water, rangeland, minerals (petroleum), and soil. The area of the elementary school curriculum with which each correlates is indicated. Lists of general and specific objectives are followed by suggested teaching procedures, including ideas for introducing the…

  20. Microcontroller Unit

    International Nuclear Information System (INIS)

    Tulaev, A.B.

    1994-01-01

    The general purpose micro controller unit based on 8-bit single-chip microcomputer of the MCS-51 family is described. The controller has the data and program memories, a serial interface and an external bus for functional I/O extensions. The controller consists of a microcomputer chip, up to 4 ROM-RAM chips and 10 SSI and MSI chips, and it measures 160x120 mm. Both hardware and software micro system debugging tools are described. (author). 8 refs., 1 fig., 1 tab

  1. Solar unit

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, A M; Trushevskiy, S N; Tveryanovich, E V

    1982-01-01

    A solar unit is proposed which contains an inclined solar collector with supply and outlet pipelines, the first of which is connected to the source of a heat carrier, while the second is connected through the valve to the tank for collecting heated heat carrier equipped with a device for recovery. In order to improve the effectiveness of heating the heat carrier, it additionally contains a concentrator of solar radiation and a device for maintaining a level of the heat carrier in the collector in the zone of the focal spot of the concentrator, while the heat pipeline is connected to the source of the heat carrier with the help of a device for maintaining the level of the heat carrier.

  2. Termination unit

    Science.gov (United States)

    Traeholt, Chresten [Frederiksberg, DK; Willen, Dag [Klagshamn, SE; Roden, Mark [Newnan, GA; Tolbert, Jerry C [Carrollton, GA; Lindsay, David [Carrollton, GA; Fisher, Paul W [Heiskell, TN; Nielsen, Carsten Thidemann [Jaegerspris, DK

    2014-01-07

    This invention relates to a termination unit comprising an end-section of a cable. The end section of the cable defines a central longitudinal axis and comprising end-parts of N electrical phases, an end-part of a neutral conductor and a surrounding thermally insulation envelope adapted to comprising a cooling fluid. The end-parts of the N electrical phases and the end-part of the neutral conductor each comprising at least one electrical conductor and being arranged in the cable concentrically around a core former with a phase 1 located relatively innermost, and phase N relatively outermost in the cable, phase N being surrounded by the neutral conductor, electrical insulation being arrange between neighboring electrical phases and between phase N and the neutral conductor, and wherein the end-parts of the neutral conductor and the electrical phases each comprise a contacting surface electrically connected to at least one branch current lead to provide an electrical connection: The contacting surfaces each having a longitudinal extension, and being located sequentially along the longitudinal extension of the end-section of the cable. The branch current leads being individually insulated from said thermally insulation envelope by individual electrical insulators.

  3. Termination unit

    Energy Technology Data Exchange (ETDEWEB)

    Traeholt, Chresten; Willen, Dag; Roden, Mark; Tolbert, Jerry C.; Lindsay, David; Fisher, Paul W.; Nielsen, Carsten Thidemann

    2016-05-03

    Cable end section comprises end-parts of N electrical phases/neutral, and a thermally-insulation envelope comprising cooling fluid. The end-parts each comprises a conductor and are arranged with phase 1 innermost, N outermost surrounded by the neutral, electrical insulation being between phases and N and neutral. The end-parts comprise contacting surfaces located sequentially along the longitudinal extension of the end-section. A termination unit has an insulating envelope connected to a cryostat, special parts at both ends comprising an adapter piece at the cable interface and a closing end-piece terminating the envelope in the end-section. The special parts houses an inlet and/or outlet for cooling fluid. The space between an inner wall of the envelope and a central opening of the cable is filled with cooling fluid. The special part at the end connecting to the cryostat houses an inlet or outlet, splitting cooling flow into cable annular flow and termination annular flow.

  4. The contract of reactor design in Yonggwang - 3. 4 nuclear power plant

    International Nuclear Information System (INIS)

    1987-01-01

    This contract document consist of five chapters which have contract clauses. It includes definition of the terms, insurance, the cancellation of contracts and management of the business in the first chapter. The second chapter deals with provision, including the scope of the supply and schedule, test, guarantee, the condition of delivery and transfer of ownership and rejection and exchange. The third chapter is about an agreement on prices, the terms of prices and a tax. The fourth chapter describes provision of services. The last is about the introduction of technology.

  5. Sealing of investigation boreholes, Phase 4 - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland [Drawrite AB, Luleaa Technical University, Luleaa (Sweden); Ramqvist, Gunnar [El-Tekno AB, Figeholm (Sweden); Bockgaard, Niclas [Golder Associates, Goeteborg (Sweden); Ekman, Lennart [LE Geokonsult AB, Baelinge (Sweden)

    2011-09-15

    The report describes the outcome of Phase 4 of the project 'Sealing of investigation boreholes', which deals with 1) characterization and planning of borehole sealing, 2) performance and quality assessment, 3) sealing of large diameter holes, and 4) interaction of clay and concrete plugs. A specific goal was to find ways to characterize, plan and seal of boreholes so that their impact on the overall hydraulic performance of the repository rock can predicted and controlled. The work comprised selection of representative 'reference holes' at the Laxemar and Forsmark sites for development of a general programme for planning and simulating implementation of borehole plugging campaigns, considering also cost issues. A second aim was to define and quantify the role of seals in the reference holes for finding out how important sealing really is. A third was to test a practical way to seal large diameter boreholes and a fourth to find out how concrete matures and performs in contact with smectite clay. The study demonstrated, in conclusion, the need for developing techniques for preparing deep boreholes before lasting seals are installed in them, since poor sealing can short-circuit hydraulically important fracture zones intersected by the holes. The practically oriented sealing activities showed that the technique developed for tight sealing of large-diameter boreholes is practical and feasible. The issue of chemical stability was investigated by testing the performance and constitution of a plug consisting of CBI concrete in contact with smectite-rich seals for almost three years. This study showed that none of them underwent substantial degradation in this period of time, but chemical reactions and thereby generated changes in physical behaviour of the plug components had taken place, particularly in the clay. The rate of degradation is, however, not yet known. It was concluded from this study that it is suitable to carry out a corresponding investigation of the plugs in the 'twin' hole (KA1621G02) at the - 220 m level at Aespoe HRL and to develop other concrete brands of more inert type. A number of not yet solved problems in constructing and installing seals have been identified in the course of the study. They are defined and listed in the report and should be considered in the planning of future work for providing a basis for full-scale implementation.

  6. Sealing of investigation boreholes, Phase 4 - Final report

    International Nuclear Information System (INIS)

    Pusch, Roland; Ramqvist, Gunnar; Bockgaard, Niclas; Ekman, Lennart

    2011-09-01

    The report describes the outcome of Phase 4 of the project 'Sealing of investigation boreholes', which deals with 1) characterization and planning of borehole sealing, 2) performance and quality assessment, 3) sealing of large diameter holes, and 4) interaction of clay and concrete plugs. A specific goal was to find ways to characterize, plan and seal of boreholes so that their impact on the overall hydraulic performance of the repository rock can predicted and controlled. The work comprised selection of representative 'reference holes' at the Laxemar and Forsmark sites for development of a general programme for planning and simulating implementation of borehole plugging campaigns, considering also cost issues. A second aim was to define and quantify the role of seals in the reference holes for finding out how important sealing really is. A third was to test a practical way to seal large diameter boreholes and a fourth to find out how concrete matures and performs in contact with smectite clay. The study demonstrated, in conclusion, the need for developing techniques for preparing deep boreholes before lasting seals are installed in them, since poor sealing can short-circuit hydraulically important fracture zones intersected by the holes. The practically oriented sealing activities showed that the technique developed for tight sealing of large-diameter boreholes is practical and feasible. The issue of chemical stability was investigated by testing the performance and constitution of a plug consisting of CBI concrete in contact with smectite-rich seals for almost three years. This study showed that none of them underwent substantial degradation in this period of time, but chemical reactions and thereby generated changes in physical behaviour of the plug components had taken place, particularly in the clay. The rate of degradation is, however, not yet known. It was concluded from this study that it is suitable to carry out a corresponding investigation of the plugs in the 'twin' hole (KA1621G02) at the - 220 m level at Aespoe HRL and to develop other concrete brands of more inert type. A number of not yet solved problems in constructing and installing seals have been identified in the course of the study. They are defined and listed in the report and should be considered in the planning of future work for providing a basis for full-scale implementation

  7. Margin benefit assessment of the YGN 3 cycle 1 fxy error files for COLSS and CPC overall uncertainty analyses

    International Nuclear Information System (INIS)

    Yoon, Rae Young; In, Wang Kee; Auh, Geun Sun; Kim, Hee Cheol; Lee, Sang Keun

    1994-01-01

    Margin benefits are quantitatively assessed for the Yonggwang Unit 3 (YGN 3) Cycle 1 planar radial peaking factor (Fxy) error files for each time-in-life, i.e., BOC, IOC, MOC and EOC. The generic Fxy error file (FXYMEQO) is presently used for Yonggwang Unit 3 Cycle 1 COLSS (Core Operating Limit Supervisory System) and CPC (Core Protection Calculator) Overall Uncertainty Analyses (OUA). However, because this file is more conservative than the plant/cycle specific Fxy error files, COLSS and CPC thermal margins (DNB-OPM) for the generic Fxy error file are less than those of the plant/cycle specific Fxy error file. Therefore, the YGN 3 Cycle 1 Fxy error files were generated and analyzed by the modified codes for Yonggwang Plants. The YGN 3 Cycle 1 Fxy error files gave the increased thermal margin by about 1% for COLSS and CPC, respectively

  8. The applicability of ALPHA/PHOENIX/ANC nuclear design code system on Korean standard PWR's

    International Nuclear Information System (INIS)

    Lee, Kookjong; Choi, Kie-Yong; Lee, Hae-Chan; Roh, Eun-Rae

    1996-01-01

    For the Korean Standard Nuclear Power Plant (KSNPP) designed based on Combustion Engineering (CE) System 80, the Westinghouse nuclear design code system ALPHA/PHOENIX/ANC was applied to the follow-up design of initial and reload core of KSNPP. The follow-up design results of Yonggwang Unit 3 Cycle 1, 2 and Yonggwang Unit 4 Cycle 1 have shown good agreements with the measured data. The assemblywise power distributions have shown less than 2% average differences and critical boron concentrations have shown less than 20 ppm differences. All the low power physics test parameters are in good agreement. Consequently, APA design code system can be applied to KNSPP cores. (author)

  9. SI units in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Iyer, P S [Bhabha Atomic Research Centre, Bombay (India). Div. of Radiation Protection

    1978-11-01

    The proposal of the International Commission on Radiation Units and Measurements that the special units of radiation and radioactivity-roentgen, rad, rem and curie-be replaced by the International System (SI) of Units has been accepted by international bodies. This paper reviews the resons for introducing the new units and their features. The relation between the special units and the corresponding SI units is discussed with examples. In spite of anticipated difficulties, the commission recommends a smooth and efficient changeover to the SI units in ten years.

  10. Unit Cost Compendium Calculations

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Unit Cost Compendium (UCC) Calculations raw data set was designed to provide for greater accuracy and consistency in the use of unit costs across the USEPA...

  11. United States housing, 2012

    Science.gov (United States)

    Delton Alderman

    2013-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.

  12. United Cerebral Palsy

    Science.gov (United States)

    ... your local affiliate Find your local affiliate United Cerebral Palsy United Cerebral Palsy (UCP) is a trusted resource for individuals with Cerebral Palsy and other disabilities and their networks. Individuals with ...

  13. Malaria Treatment (United States)

    Science.gov (United States)

    ... Providers, Emergency Consultations, and General Public. Contact Us Malaria Treatment (United States) Recommend on Facebook Tweet Share Compartir Treatment of Malaria: Guidelines For Clinicians (United States) Download PDF version ...

  14. A multiplicity logic unit

    International Nuclear Information System (INIS)

    Bialkowski, J.; Moszynski, M.; Zagorski, A.

    1981-01-01

    The logic diagram principle of operation and some details of the design of the multiplicity logic unit are presented. This unit was specially designed to fulfil the requirements of a multidetector arrangement for gamma-ray multiplicity measurements. The unit is equipped with 16 inputs controlled by a common coincidence gate. It delivers a linear output pulse with the height proportional to the multiplicity of coincidences and logic pulses corresponding to 0, 1, ... up to >= 5-fold coincidences. These last outputs are used to steer the routing unit working with the multichannel analyser. (orig.)

  15. ENERGY STAR Unit Reports

    Data.gov (United States)

    Department of Housing and Urban Development — These quarterly Federal Fiscal Year performance reports track the ENERGY STAR qualified HOME units that Participating Jurisdictions record in HUD's Integrated...

  16. 31 CFR 515.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 515.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including the Trust Territory of...

  17. 31 CFR 500.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 500.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof, including U.S. trust territories...

  18. 31 CFR 535.321 - United States; continental United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States; continental United... General Definitions § 535.321 United States; continental United States. The term United States means the United States and all areas under the jurisdiction or authority thereof including the Trust Territory of...

  19. Neighbors United for Health

    Science.gov (United States)

    Westhoff, Wayne W.; Corvin, Jaime; Virella, Irmarie

    2009-01-01

    Modeled upon the ecclesiastic community group concept of Latin America to unite and strengthen the bond between the Church and neighborhoods, a community-based organization created Vecinos Unidos por la Salud (Neighbors United for Health) to bring health messages into urban Latino neighborhoods. The model is based on five tenants, and incorporates…

  20. Smart Rocking Armour Units

    NARCIS (Netherlands)

    Hofland, B.; Arefin, Syed Shamsil; van der Lem, Cock; van gent, Marcel

    2018-01-01

    This paper describes a method to measure the rocking motion of lab-scale armour units. Sensors as found in mobile phones are used. These sensors, data-storage and battery are all embedded in the model units, such that they can be applied without wires attached to them. The technique is applied to

  1. METRIC context unit architecture

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, R.O.

    1988-01-01

    METRIC is an architecture for a simple but powerful Reduced Instruction Set Computer (RISC). Its speed comes from the simultaneous processing of several instruction streams, with instructions from the various streams being dispatched into METRIC's execution pipeline as they become available for execution. The pipeline is thus kept full, with a mix of instructions for several contexts in execution at the same time. True parallel programming is supported within a single execution unit, the METRIC Context Unit. METRIC's architecture provides for expansion through the addition of multiple Context Units and of specialized Functional Units. The architecture thus spans a range of size and performance from a single-chip microcomputer up through large and powerful multiprocessors. This research concentrates on the specification of the METRIC Context Unit at the architectural level. Performance tradeoffs made during METRIC's design are discussed, and projections of METRIC's performance are made based on simulation studies.

  2. Thermal Analysis for Environmental Qualification of Kori Nuclear power plant unit 3 and 4

    International Nuclear Information System (INIS)

    Seo, Kwi Hyun; Byun, Choong Sup; Song, Dong Soo

    2006-01-01

    This paper shows the temperature profiles of safety related electrical equipment exposed to MSLB inside containment. It must be demonstrated that the LOCA qualification conditions exceed or are equivalent to the maximum calculated MSLB conditions. COPATTA as Bechtel's vendor code is used for the containment pressure and temperature prediction in power uprating project for Kori 3,4 and Yonggwang 1,2 nuclear power plants(NPPs). However, CONTEMPT-LT/028 is used for calculating the containment pressure and temperatures in equipment qualification project for the same NPPs. Power uprating code that is, COPATTA benchmarking study performed in six equipment at saturation temperature and surface temperature. Specially, thermal analysis carefully investigate that view point environmental qualification and NUREG- 0588 be mentioned in regard to safety-related heat sink it boundary condition or geometry information

  3. Thermal Analysis for Environmental Qualification of Kori Nuclear power plant unit 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwi Hyun [ENERGEO Inc., Sungnam (Korea, Republic of); Byun, Choong Sup; Song, Dong Soo [KEPRI, Taejon (Korea, Republic of)

    2006-07-01

    This paper shows the temperature profiles of safety related electrical equipment exposed to MSLB inside containment. It must be demonstrated that the LOCA qualification conditions exceed or are equivalent to the maximum calculated MSLB conditions. COPATTA as Bechtel's vendor code is used for the containment pressure and temperature prediction in power uprating project for Kori 3,4 and Yonggwang 1,2 nuclear power plants(NPPs). However, CONTEMPT-LT/028 is used for calculating the containment pressure and temperatures in equipment qualification project for the same NPPs. Power uprating code that is, COPATTA benchmarking study performed in six equipment at saturation temperature and surface temperature. Specially, thermal analysis carefully investigate that view point environmental qualification and NUREG- 0588 be mentioned in regard to safety-related heat sink it boundary condition or geometry information.

  4. Decision unit program

    International Nuclear Information System (INIS)

    Madjar, N.; Pastor, C.; Chambon, B.; Drain, D.; Giorni, A.; Dauchy, A.

    1981-01-01

    A decision unit has been built to simplify the electronic logic set-up in multi-detectors experiments. This unit, designed with fast memories used as decision making tables, replaces conventional logic modules. Nine inputs are provided for receiving the fast detector signals (charged particles, gammas, neutrons, ...). Fifteen independent outputs allow the identification of the choosen events among the 2 9 possible events. A CAMAC interface between the unit and the computer, or a manual control auxiliary module, is used to load, in the memory, the pattern of the choosen events [fr

  5. Smart Rocking Armour Units

    OpenAIRE

    Hofland, B.; Arefin, Syed Shamsil; van der Lem, Cock; van gent, Marcel

    2018-01-01

    This paper describes a method to measure the rocking motion of lab-scale armour units. Sensors as found in mobile phones are used. These sensors, data-storage and battery are all embedded in the model units, such that they can be applied without wires attached to them. The technique is applied to double-layer units in order to compare the results to the existing knowledge for this type of armour layers. In contrast to previous research, the gyroscope reading is used to determine the (rocking)...

  6. Allocating multiple units

    DEFF Research Database (Denmark)

    Tranæs, Torben; Krishna, Kala

    2002-01-01

    This paper studies the allocation and rent distribution in multi-unit, combinatorial-bid auctions under complete information. We focus on the natural multi-unit analogue of the first-price auction, where buyers bid total payments, pay their bids, and where the seller allocates goods to maximize his...... auction, which is the multi unit analogue of a second-price auction. Furthermore, we characterize these equilibria when valuations take a number of different forms: diminishing marginal valuations, increasing average valuations, and marginal valuations with single turning points...

  7. Tax Unit Boundaries

    Data.gov (United States)

    Kansas Data Access and Support Center — The Statewide GIS Tax Unit boundary file was created through a collaborative partnership between the State of Kansas Department of Revenue Property Valuation...

  8. Insects: An Interdisciplinary Unit

    Science.gov (United States)

    Leger, Heather

    2007-01-01

    The author talks about an interdisciplinary unit on insects, and presents activities that can help students practice communication skills (interpersonal, interpretive, and presentational) and learn about insects with hands-on activities.

  9. UnitedHealth Group

    Science.gov (United States)

    UnitedHealth Group provides accessible and affordable services, improved quality of care, coordinated health care efforts, and a supportive environment for shared decision making between patients and their physicians.

  10. Operable Unit Boundaries

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset consists of operable unit data from multiple Superfund sites in U.S. EPA Region 8. These data were acquired from multiple sources at different times and...

  11. Flywheel and power unit

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, R.W.

    1992-10-28

    A power unit, e.g. for an electrically driven vehicle, incorporates a flywheel for storing kinetic energy and a battery for storing electrical energy. The battery is incorporated as a substantial part of the rotating mass of the flywheel. Preferably the unit further includes an electrical machine being a motor or generator or machine operable either as a motor or a generator for transferring energy between the battery and the flywheel and/or for the input or output of rotary energy therefrom or thereto. The motor may be used for powering the flywheel and may also operate in a regenerative mode for recharging the unit on de-acceleration of the vehicle. The unit of the invention may also be utilized as an electrical stored power source, e.g. wind or water driven. (author)

  12. Does size matter? Animal units and animal unit months

    Science.gov (United States)

    Lamar Smith; Joe Hicks; Scott Lusk; Mike Hemmovich; Shane Green; Sarah McCord; Mike Pellant; John Mitchell; Judith Dyess; Jim Sprinkle; Amanda Gearhart; Sherm Karl; Mike Hannemann; Ken Spaeth; Jason Karl; Matt Reeves; Dave Pyke; Jordan Spaak; Andrew Brischke; Del Despain; Matt Phillippi; Dave Weixelmann; Alan Bass; Jessie Page; Lori Metz; David Toledo; Emily Kachergis

    2017-01-01

    The concepts of animal units, animal unit months, and animal unit equivalents have long been used as standards for range management planning, estimating stocking rates, reporting actual use, assessing grazing fees, ranch appraisal, and other purposes. Increasing size of cattle on rangelands has led some to suggest that the definition of animal units and animal unit...

  13. UniTed

    OpenAIRE

    Harma, Eero

    2010-01-01

    UniTed on Teddy boy- tyylistä inspiroitunut kevät/kesä mallisto naisille.Mallistossa yhdistyy perinteinen teddy boy- vaatetus ja klassinen feminiinisyys, sekä menneisyys ja nykyisyys. Suunnittelun lähtökohtia olivat naisellisuus, tyylikkyys ja pyrkimys luoda nykyaikaista suunnittelua menneisyydestä lainaillen. United is a teddy boy- style inspired spring/summer collection for women. The collection combines traditional Teddy boy style with classical feminity and past with the present. The b...

  14. Freestanding midwifery unit versus obstetric unit

    DEFF Research Database (Denmark)

    Overgaard, Charlotte; Møller, Anna Margrethe; Fenger-Grøn, Morten

    2011-01-01

    low-risk women intending FMU birth and a matched control group of 839 low-risk women intending OU birth were included at the start of care in labour. OU women were individually chosen to match selected obstetric/socio-economic characteristics of FMU women. Analysis was by intention to treat. Main......Objective To compare perinatal and maternal morbidity and birth interventions in low-risk women giving birth in two freestanding midwifery units (FMUs) and two obstetric units (OUs). Design A cohort study with a matched control group. Setting The region of North Jutland, Denmark. Participants 839...... women were significantly less likely to experience an abnormal fetal heart rate (RR: 0.3, 95% CI 0.2 to 0.5), fetal–pelvic complications (0.2, 0.05 to 0.6), shoulder dystocia (0.3, 0.1 to 0.9), occipital–posterior presentation (0.5, 0.3 to 0.9) and postpartum haemorrhage >500 ml (0.4, 0.3 to 0...

  15. Rapanos v. United States & Carabell v. United States

    Science.gov (United States)

    Documents associated with guidance for implementing the definition of waters of the United States under the Clean Water Act following the Rapanos v. United States, and Carabell v. United States Supreme Court decision.

  16. Gas-centrifuge unit

    International Nuclear Information System (INIS)

    Stark, T.M.

    1977-01-01

    An isotope-enrichment unit is described for separating a gaseous mixture feedstock including a compound of a light nuclear isotope at a predetermined concentration and a compound of a heavy nuclear isotope at a predetermined concentration into at least two unit-output fractions including a waste fraction depleted in the light isotope to a predetermined concentration and a product fraction enriched in the light isotope to a predetermined concentration. The unit comprises a first group of cascades of gas centrifuges, each cascade having an enriching stage, a stripping stage, an input, a light-fraction output, and a heavy-fraction output for separating the gaseous-mixture feed stock into light and heavy gaseous-mixture fractions; and an auxillary cascade

  17. Mechanical strainer unit

    International Nuclear Information System (INIS)

    Kraeling, J.B.; Netkowicz, R.J.; Schnall, I.H.

    1983-01-01

    The mechanical strainer unit is connected to a flanged conduit which originates in and extends out of a suppression chamber in a nuclear reactor. The strainer includes a plurality of centrally apertured plates positioned along a common central axis and in parallel and spaced relationship. The plates have a plurality of bores radially spaced about the central axis. Spacer means such as washers are positioned between adjacent plates to maintain the plates is spaced relationship and form communicating passages of a predetermined size to the central apertures. Connecting means such as bolts or studs extend through the aligned bores to maintain the unit in assembled relationship and secure the unit to the pipe. By employing perforated plates and blocking off certain of the communicating passages, a dual straining effect can be achieved

  18. Mobile emergency response unit

    International Nuclear Information System (INIS)

    Kadi, W.J.; Trolan, R.T.; Becker, J.F.

    1979-01-01

    The Hotspot quick-response unit was the solution to a requirement to find, identify, and control areas of radioactive contamination at the scene of a nuclear weapons accident. The unit consists of two trucks and two trailers, and is designed to be transported by one U.S. Air Force C-141. One truck (generator truck) carries a 40 kW generator-heater-air conditioner combination, spare tires, and accessories. The other (water truck) carries supplies and a 250-gal water tank. One trailer (counting trailer) contains detecting, counting, and recording equipment. The other (decontaminating trailer) contains a shower, sink, 30-gal hot water tank, and supplies

  19. Transfer Factors of Nuclides for Five Fish Species Inhabiting the Sea near the Yonggwang Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kwangmuk; Choi, Yongho; Jun, In; Kim, Byungho; Keum, Dongkwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    The IAEA is going to publish a handbook of the TF values of various radionuclides for a number of plant and animal species. However, it is recommended that they be used in case there is no site-specific data. This is because TF values can vary considerably with wild-life species and environmental conditions. Therefore, it is necessary to urgently establish our own database of wild-life transfer factors for use in the wild-life dose assessment probably in the near future. In the present study, TF values of various radionuclides were investigated for several marine fish species living around the Younggwang NPP. It was done by measuring the concentrations of stable isotopes in fish and seawater samples. TF values of 21 nuclides were measured for five fish species inhabiting the sea near the Younggwang NPP. They showed considerable variations with the nuclides and fish species. Determination of TF values needs to be extended to various kinds of domestic wild lives so as to establish an input data file for a Korean assessment model such as K-BIOTA.

  20. A feasibility study on the longer cycle operation of Yonggwang nuclear power plants 3 and 4 (3 rd quarter report)

    Energy Technology Data Exchange (ETDEWEB)

    Zee Sung Kyun; Song, Jae Woong; Ha, Young Joon; Kim, Kyu Tae [Korea Advanced Institute of Science and Technolgoy, Taejon (Korea, Republic of)

    1996-04-01

    In this report, described are results of the feasibility study on applying for the 18-month cycle in Korean Standard Nuclear Power Plants (KSNPs). This report contains results of safety and economic evaluations, radiation source analysis, an effect on changing the calibration period for each component of NSSS, and review on the related regulating codes. 12 refs., 34 tabs., 28 figs. (author)

  1. Transfer of manufacturing units

    DEFF Research Database (Denmark)

    Madsen, Erik Skov; Riis, Jens Ove; Sørensen, Brian Vejrum

    2008-01-01

    The ongoing and unfolding relocation of activities is one of the major trends, that calls for attention in the domain of operations management. In particular, prescriptive models outlining: stages of the process, where to locate, and how to establish the new facilities have been studied, while...... and dilemmas to be addressed when transferring manufacturing units....

  2. United States Attorney Prosecutions

    Science.gov (United States)

    1993-10-01

    property of CocaCola Bottling Company, Fayetteville, North Carolina, of a value in excess of $100.00, in violation of Title 18 United States Code, Section...another, to-wit: a Cocacola soft drink machine, the amount of damage to said personal property being more than $200.00, in violation of North Carolina

  3. Planter unit test stand

    Science.gov (United States)

    A planter test stand was developed to evaluate individual row-crop metering units in early 2013. This test stand provided the ability to quantify actual seed metering in terms of population, seed spacing, skips, and multiples over a range of meter RPMs and vacuum pressures. Preliminary data has been...

  4. United Kingdom's experience

    International Nuclear Information System (INIS)

    Drummond, S.M.

    1994-01-01

    This is a presentation of the United Kingdom's experience with power transmission open access. The topics of the presentation include the objectives of changing, commercial arrangements and economic drivers, long term effects, the effects of moving to a more competitive environment, and factors affecting open access such as political climate and market regulation

  5. Whale Teaching Unit.

    Science.gov (United States)

    Peninsula Humane Society, San Mateo, CA.

    Materials in this teaching unit are designed to foster an interest in whale preservation among intermediate grade and junior high school students. Several readings provide background information on various types of whales and the economic value of whales. Student activities include a true and false game, a crossword, and a mobile. A resource list…

  6. Multifunctional centrifugal grinding unit

    Science.gov (United States)

    Sevostyanov, V. S.; Uralskij, V. I.; Uralskij, A. V.; Sinitsa, E. V.

    2018-03-01

    The article presents scientific and engineering developments of multifunctional centrifugal grinding unit in which the selective effect of grinding bodies on the crushing material is realized, depending on its physical and mechanical characteristics and various schemes for organizing the technological process

  7. United in change

    NARCIS (Netherlands)

    Hanneke Posthumus; Josje den Ridder; Joep de Hart

    2014-01-01

    Original title: Verenigd in verandering The importance of citizens who unite in civil society organisations is broadly recognised. Organisations bind people to each other, to the community and to the political system. How are civil-society organisations in the Netherlands faring? Is there

  8. Unit III: International Conflict.

    Science.gov (United States)

    Maxey, Phyllis

    1983-01-01

    This lesson helps students understand the global network involved in international events. Students have an opportunity to examine the impact of international law and the role of international organizations, national governments, and private individuals in the effort to secure the release of United States hostages in Iran. (AM)

  9. Unit 16 - Output

    OpenAIRE

    Unit 16, CC in GIS; Star, Jeffrey L.

    1990-01-01

    This unit discusses issues related to GIS output, including the different types of output possible and the hardware for producing each. It describes text, graphic and digital data that can be generated by a GIS as well as line printers, dot matrix printers/plotters, pen plotters, optical scanners and cathode ray tubes (CRTs) as technologies for generating the output.

  10. Defining line replaceable units

    NARCIS (Netherlands)

    Parada Puig, J. E.; Basten, R. J I

    2015-01-01

    Defective capital assets may be quickly restored to their operational condition by replacing the item that has failed. The item that is replaced is called the Line Replaceable Unit (LRU), and the so-called LRU definition problem is the problem of deciding on which item to replace upon each type of

  11. Contamination analysis unit

    International Nuclear Information System (INIS)

    Gregg, H.R.; Meltzer, M.P.

    1996-01-01

    The portable Contamination Analysis Unit (CAU) measures trace quantities of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surfaces by measuring residual hazardous surface contamination, such as tritium and trace organics. It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings. 1 fig

  12. Combustion strategy : United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Greenhalgh, D. [Heriot-Watt Univ., Edingburgh, Scotland (United Kingdom). School of Engineering and Physical Sciences

    2009-07-01

    The United Kingdom's combustion strategy was briefly presented. Government funding sources for universities were listed. The United Kingdom Research Councils that were listed included the Arts and Humanities Research Council (AHRC) and the Biotechnology and Biological Sciences Research Council (BBSRC); the Engineering and Physical Sciences Research Council (EPSRC); the Economic and Social Research Council; the Medical Research Council; the Natural Environment Research Council; and the Science and Technology Facilities Council. The EPSRC supported 65 grants worth 30.5 million pounds. The combustion industry was noted to be dominated by three main players of which one was by far the largest. The 3 key players were Rolls-Royce; Jaguar Land Rover; and Doosan Babcock. Industry and government involvement was also discussed for the BIS Technology Strategy Board, strategy technology areas, and strategy application areas.

  13. Uranium chemistry research unit

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The initial field of research of this Unit, established in 1973, was the basic co-ordination chemistry of uranium, thorium, copper, cobalt and nickel. Subsequently the interest of the Unit extended to extractive metallurgy relating to these metals. Under the term 'co-ordination chemistry' is understood the interaction of the central transition metal ion with surrounding atoms in its immediate vicinity (within bonding distance) and the influence they have on each other - for example, structural studies for determining the number and arrangement of co-ordinated atoms and spectrophotometric studies to establish how the f electron energy levels of uranium are influenced by the environment. New types of uranium compounds have been synthesized and studied, and the behaviour of uranium ions in non-aqueous systems has also received attention. This work can be applied to the development and study of extractants and new extractive processes for uranium

  14. Laser color recording unit

    Science.gov (United States)

    Jung, E.

    1984-05-01

    A color recording unit was designed for output and control of digitized picture data within computer controlled reproduction and picture processing systems. In order to get a color proof picture of high quality similar to a color print, together with reduced time and material consumption, a photographic color film material was exposed pixelwise by modulated laser beams of three wavelengths for red, green and blue light. Components of different manufacturers for lasers, acousto-optic modulators and polygon mirrors were tested, also different recording methods as (continuous tone mode or screened mode and with a drum or flatbed recording principle). Besides the application for the graphic arts - the proof recorder CPR 403 with continuous tone color recording with a drum scanner - such a color hardcopy peripheral unit with large picture formats and high resolution can be used in medicine, communication, and satellite picture processing.

  15. Optimally Locating MARFORRES Units

    OpenAIRE

    Salmeron, Javier; Dell, Rob

    2015-01-01

    Javier Salmeron and Rob Dell The U.S. Marine Forces Reserve (USMCR, MARFORRES) is conducting realignment studies where discretionary changes may benefit from formal mathematical analysis. This study has developed an optimization tool to guide and/or support Commander, MARFORRES (CMFR) decisions. A prototype of the optimization tool has been tested with data from the units and Reserve Training Centers (RTCs) in the San Francisco, CA and Sacramento, CA areas. Prepared for: MARFORRES, POC:...

  16. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  17. Radiation quantities and units

    International Nuclear Information System (INIS)

    1980-01-01

    This report supersedes ICRU Report 19. Since ICRU Report 19 was published, a number of discussions have taken place between members of the Report Committee on Fundamental Quantities and Units and other workers in the field. Some of these discussions have resulted in the acceptance of certain modifications in the material set out in Report 19 and these modifications are incorporated in the current report. In addition, there has been some expansion and rearrangement of the material in the earlier report. In line, with providing more didactic material and useful source material for other ICRU reports, the general considerations in subsection 1.A of Report 19 have been expanded and placed in a separate subsection. The additional material includes discussions of four terms that are used in this document - quantity, unit, stochastic, and non-stochastic - along with a brief discussion of the mathematical formalism used in ICRU reports. As in ICRU Report 19, the definitions of quantities and units specifically designed for radiation protection (Part B) are separated from those of the general quantities (Part A). The inclusion of the index concept outlined in ICRU Report 25[4] required an extension of Part B

  18. United States rejoin ITER

    International Nuclear Information System (INIS)

    Roberts, M.

    2003-01-01

    Upon pressure from the United States Congress, the US Department of Energy had to withdraw from further American participation in the ITER Engineering Design Activities after the end of its commitment to the EDA in July 1998. In the years since that time, changes have taken place in both the ITER activity and the US fusion community's position on burning plasma physics. Reflecting the interest in the United States in pursuing burning plasma physics, the DOE's Office of Science commissioned three studies as part of its examination of the option of entering the Negotiations on the Agreement on the Establishment of the International Fusion Energy Organization for the Joint Implementation of the ITER Project. These were a National Academy Review Panel Report supporting the burning plasma mission; a Fusion Energy Sciences Advisory Committee (FESAC) report confirming the role of ITER in achieving fusion power production, and The Lehman Review of the ITER project costing and project management processes (for the latter one, see ITER CTA Newsletter, no. 15, December 2002). All three studies have endorsed the US return to the ITER activities. This historical decision was announced by DOE Secretary Abraham during his remarks to employees of the Department's Princeton Plasma Physics Laboratory. The United States will be working with the other Participants in the ITER Negotiations on the Agreement and is preparing to participate in the ITA

  19. United States advanced technologies

    International Nuclear Information System (INIS)

    Longenecker, J.R.

    1985-01-01

    In the United States, the advanced technologies have been applied to uranium enrichment as a means by which it can be assured that nuclear fuel cost will remain competitive in the future. The United States is strongly committed to the development of advanced enrichment technology, and has brought both advanced gas centrifuge (AGC) and atomic vapor laser isotope separation (AVLIS) programs to a point of significant technical refinement. The ability to deploy advanced technologies is the basis for the confidence in competitive future price. Unfortunately, the development of advanced technologies is capital intensive. The year 1985 is the key year for advanced technology development in the United States, since the decision on the primary enrichment technology for the future, AGC or AVLIS, will be made shortly. The background on the technology selection process, the highlights of AGC and AVLIS programs and the way to proceed after the process selection are described. The key objective is to maximize the sales volume and minimize the operating cost. This will help the utilities in other countries supply low cost energy on a reliable, long term basis. (Kako, I.)

  20. The Military Emergency Unit

    International Nuclear Information System (INIS)

    Gonzalez Requena, J. M.

    2007-01-01

    One of the most justified and pressing demands that society makes of the State, requiring a fast, forceful and effective response, is that it guarantees the safety of people and their assets when a disaster seriously endangers them. At the proposal of the President of the Government, the Cabinet of Ministers, in its meeting held on October 7, 2005, agreed to create the Military Emergency Unit, known since the as the UME. Its mission is to intervene anywhere in the national territory when the President of the Government, or the Minister to whom he delegates, so decides in order to assure the safety and welfare of citizens in cases of serious risk, disaster, catastrophe or any other public need. The UME is organically incorporated into the Ministry of Defense and its actions may be supported with all the available human and material needs of the Armed Forces. Availability and effectiveness, with calmness and humility, have characterized the early actions of the Military Emergency Unit and are the guidelines for future action. The first steps of this military unit have focused on a clear goal: collaboration and participation in situations whose seriousness requires the coordination of different forces in order to immediately respond to them. The UME is the States tool to join forces and, with other administration and institutions, help to rapidly and effectively deal with emergencies. It has taken its first step and achieved the capacity specified in the UME Operations Order for 2007. The 150 men and women per battalion, plus the 80 in the Gando detachment, are on active duty and have sufficient material means to deploy, if necessary and when requested by the regions, town councils an other administrative bodies, to help in the extinction of forest fires. (Author)

  1. Decommissioning Unit Cost Data

    International Nuclear Information System (INIS)

    Sanford, P. C.; Stevens, J. L.; Brandt, R.

    2002-01-01

    The Rocky Flats Closure Site (Site) is in the process of stabilizing residual nuclear materials, decommissioning nuclear facilities, and remediating environmental media. A number of contaminated facilities have been decommissioned, including one building, Building 779, that contained gloveboxes used for plutonium process development but did little actual plutonium processing. The actual costs incurred to decommission this facility formed much of the basis or standards used to estimate the decommissioning of the remaining plutonium-processing buildings. Recent decommissioning activities in the first actual production facility, Building 771, implemented a number of process and procedural improvements. These include methods for handling plutonium contaminated equipment, including size reduction, decontamination, and waste packaging, as well as management improvements to streamline planning and work control. These improvements resulted in a safer working environment and reduced project cost, as demonstrated in the overall project efficiency. The topic of this paper is the analysis of how this improved efficiency is reflected in recent unit costs for activities specific to the decommissioning of plutonium facilities. This analysis will allow the Site to quantify the impacts on future Rocky Flats decommissioning activities, and to develop data for planning and cost estimating the decommissioning of future facilities. The paper discusses the methods used to collect and arrange the project data from the individual work areas within Building 771. Regression and data correlation techniques were used to quantify values for different types of decommissioning activities. The discussion includes the approach to identify and allocate overall project support, waste management, and Site support costs based on the overall Site and project costs to provide a ''burdened'' unit cost. The paper ultimately provides a unit cost basis that can be used to support cost estimates for

  2. Unit for air decontamination

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  3. Waste Water Treatment Unit

    International Nuclear Information System (INIS)

    Ramadan, A.E.K.

    2004-01-01

    A wastewater treatment plant to treat both the sanitary and industrial effluent originated from process, utilities and off site units of the refinery is described. The purpose is to obtain at the end of the treatment plant, a water quality that is in compliance with contractual requirements and relevant environmental regulations. first treatment (pretreatment). Primary de-oiling, Equalization, Neutralization, Secondary de-oiling. Second treatment (Biological), The mechanism of BOD removal, Biological flocculation, Nutrient requirements, Nitrification, De-nitrification, Effect of temperature, Effect of ph, Toxicity

  4. Applied Meteorology Unit (AMU)

    Science.gov (United States)

    Bauman, William; Crawford, Winifred; Barrett, Joe; Watson, Leela; Wheeler, Mark

    2010-01-01

    This report summarizes the Applied Meteorology Unit (AMU) activities for the first quarter of Fiscal Year 2010 (October - December 2009). A detailed project schedule is included in the Appendix. Included tasks are: (1) Peak Wind Tool for User Launch Commit Criteria (LCC), (2) Objective Lightning Probability Tool, Phase III, (3) Peak Wind Tool for General Forecasting, Phase II, (4) Upgrade Summer Severe Weather Tool in Meteorological Interactive Data Display System (MIDDS), (5) Advanced Regional Prediction System (ARPS) Data Analysis System (ADAS) Update and Maintainability, (5) Verify 12-km resolution North American Model (MesoNAM) Performance, and (5) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) Graphical User Interface.

  5. An ISOLDE target unit

    CERN Multimedia

    Maximilien Brice

    2002-01-01

    A good dozen different targets are available for ISOLDE, made of different materials and equipped with different kinds of ion-sources, according to the needs of the experiments. Each separator (GPS: general purpose; HRS: high resolution) has its own target. Because of the high radiation levels, robots effect the target changes, about 80 times per year. In the standard unit shown in picture _01, the target is the cylindrical object in the front. It contains uranium-carbide kept at a temperature of 2200 deg C, necessary for the isotopes to be able to escape. At either end, one sees the heater current leads, carrying 700 A. The Booster beam, some 3E13 protons per pulse, enters the target from left. The evaporated isotope atoms enter a hot-plasma ion source (the black object behind the target). The whole unit sits at 60 kV potential (pulsed in synchronism with the arrival of the Booster beam) which accelerates the ions (away from the viewer) towards one of the 2 separators.

  6. The United Kingdom

    International Nuclear Information System (INIS)

    Jones, P.M.S.

    1987-01-01

    The history of nuclear development in the United Kingdom is traced, together with the factors (eg electricity demand, fossil fuel prices, political policy) that have influenced policy choices. Many of the research establishments and the fissile material production plants were established in the late 1940s. In these early years the civil and military development programmes were not separate. The initial growth period was in the 1950s when the plan was to build twelve reactors in three groups of four over ten years. The first were to be Magnox type reactors. This was trebled in 1957 and the advanced gas cooled reactor was developed. The Windscale fire in 1957 affected confidence in the nuclear programme. However, five AGR twin-reactor stations were ordered in 1964. These ran into construction problems and delay and it was not until 1980 that more new units were contemplated. The plan then was to build a pressurized water reactor at Sizewell-B. A delay to allow for the public inquiry put back the start of this until 1987 with commissioning planned for 1994. A list of the UK nuclear power stations is given and their operating performance discussed. The present situation and future prospects for nuclear power are reviewed. (U.K.)

  7. Functional unit for a processor

    NARCIS (Netherlands)

    Rohani, A.; Kerkhoff, Hans G.

    2013-01-01

    The invention relates to a functional unit for a processor, such as a Very Large Instruction Word Processor. The invention further relates to a processor comprising at least one such functional unit. The invention further relates to a functional unit and processor capable of mitigating the effect of

  8. Design of hydraulic recuperation unit

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2016-01-01

    Full Text Available This article deals with design and measurement of hydraulic recuperation unit. Recuperation unit consist of radial turbine and axial pump, which are coupled on the same shaft. Speed of shaft with impellers are 6000 1/min. For economic reasons, is design of recuperation unit performed using commercially manufactured propellers.

  9. Snakes: An Integrated Unit Plan.

    Science.gov (United States)

    Lawrence, Lisa

    This document presents an integrated unit plan on snakes targeting second grade students. Objectives of the unit include developing concepts of living things, understanding the contribution and importance of snakes to the environment, and making connections between different disciplines. The unit integrates the topic of snakes into the areas of…

  10. Inlet Geomorphology Evolution Work Unit

    Science.gov (United States)

    2015-10-30

    Coastal Inlets Research Program Inlet Geomorphology Evolution Work Unit The Inlet Geomorphology Evolution work unit of the CIRP develops methods...morphologic response. Presently, the primary tool of the Inlet Geomorphology Evolution work unit is the Sediment Mobility Tool (SMT), which allows the user

  11. United Arab Emirates.

    Science.gov (United States)

    1985-02-01

    This discussion of the United Arab Emirates focuses on the following: the people; geography; history; government; political conditions; defense; the economy; foreign relations; and relations between the US and the United Arab Emirates. In 1983 the population was estimated at 1,194,000. In 1984 the annual growth rate was negative. Life expectancy is about 60 years. Fewer than 20% of the population are UAE citizens. Indigenous Emiris are Arab; the rest of the population includes significant numbers of other Arabs -- Palestinians, Egyptians, Jordanians, Yemenis, Omanis, as well as many Iranians, Pakistanis, Indians, and West Europeans, especially in Dubai. The UAE is in the eastern Arabian Peninsula, bounded on the north by the Persian Gulf. European and Arab pirates roamed the Trucial Coast area from the 17th century into the 19th century. Early British expeditions against the pirates led to further campaigns against their headquarters. Piracy continued intermittently until 1835, when the shaikhs agreed not to engage in hostilities at sea. Primarily in reaction to the ambitions of other European countries, the UK and the Trucial States established closer bonds in an 1892 treaty. In 1968 the British government announced its decision, reaffirmed in March 1971, to end the treaty relationship with the gulf shaikhdoms. When the British protective treaty with the Trucial Shaikhdoms ended on December 1, they became fully independent. On December 2, 1971, 6 of them entered into a union called the United Arab Emirates. The 7th, Ras al-Khaimah, joined in early 1972. Administratively, the UAE is a loose federation of 7 emirates, each with its own ruler. The pace at which local government in each emirate is evolving, from traditional to modern, is set primarily by the ruler. Under the provisional constitution of 1971, each emirate reserves considerable powers, including control over mineral rights, taxation, and police powers. In this milieu, the growth of federal powers has

  12. UNITED KINGDOM: under pressure

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    While attempting bravely to sustain the legacy left by J.J. Thomson, Rutherford, Chadwick, Cockcroft, Blackett, Dirac and others earlier this century, the United Kingdom, one of the major contributors to CERN, has suffered in recent years from an erosion of the international purchasing power of the pound sterling. At the same time, the national scientific community has squabbled over the apportionment of the research cake. In recent years, the CERN budget has remained constant in real terms, but the pound has drifted steadily down. In 1984 one pound bought 3.15 Swiss francs, now it gets just over 2. The hypersensitivity which left calculations at the mercy of exchange rate hiccups was cushioned in 1988 by a new method of calculating national CERN contributions, introduced by Chris Llewellyn Smith, now the Laboratory's Director General, using less sensitive input data

  13. United Kingdom national report

    International Nuclear Information System (INIS)

    Tomkins, B.

    1998-01-01

    Report of the United Kingdom deals with life extension granted to Calder Hall and Chapelcross reactors for further 10 years operation. The two well recognised life-limiting features of Magnox type reactors are graphite core ageing and materials properties of the reactor pressure circuit components. These features have been scrutinised particularly closely and the conclusion has been reached that there are no safety factors which will necessarily limit the plant life to less than 50 years. Two other life-limiting factors are hear exchanger tubes and the heat exchanger tube failures internal to boiler shells and the integrity of the main engineering structures of the plant. It was concluded that appropriate routine ageing monitoring programs are in place in respect to these features to support continuing operation beyond 40 years

  14. Mobile power plant units

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, R

    1979-10-05

    Diesel engines of the MaK line 282 AK/332 with a cylinder power up to 160 kW are used, either as 6-cylinder or 8-cylinder in-line engine or as 12-cylinder V engine. Fuel consumption is between 207 and 212 g/kW. The engine is mounted on a frame, together with a generator. The fuel reserve in the tank will last for 8 hours. The lubricating system, the cooling water and starting air system, the switchboard system, and the frame are described. The switchboard plant is mounted either on a skid undercarriage or on the undercarriage. The plant can be operated independently or parallel to the network. The unit can be remote-controlled via push buttons or control knobs. A picture is presented of a mobile diesel aggregate which is in service in Libya.

  15. The United States

    International Nuclear Information System (INIS)

    Art, R.J.

    1991-01-01

    This paper reports that at least in the national security arena, the outcomes of bureaucratic infighting and domestic political struggles are not determined wholly by what goes on with the state. Rather struggles among contending groups are greatly affected by what is perceived to be happening outside the nation. Because external conditions give greater potency to some domestic forces over other, the external environment is never neutral in its domestic impact. The decisions of the period 1950-53 discussed above illustrate the point. But so too do the decisions of 1947, 1960-61 and 1969-72. In the 1947 case, Soviet intransigence provoked US nuclear rearmament. In the 1960-61 case, extended deterrent considerations pushed the United States to preserve its again newly discovered nuclear superiority. In the 1969-72 case, a Soviet determination to remain equal forced US acceptance of nuclear equality. And perhaps the best evidence of all, the perpetuation of parity ended the US inclination to resort to nuclear brinkmanship. In each instance, concerns about relative position heavily affected nuclear choice. Finally, the events of the past three years testify to the effects of international events on domestic choice. Under the terms of the 1987 INF Treaty, the two superpowers decided to dismantle and destroy an entire class of missiles of intermediate range (500-3000 kilometers) that both had deployed in Europe in the 1970s and 1980s, and in their June 1990 joint statement on strategic nuclear weapons, President Gorbachev and Brush agreed to cut the number of Soviet and US long range nuclear forces by 30 per cent. This agreement marks a watershed in US-Soviet strategic arm negotiations because for the first time the United States and the Soviet Union agreed in principals to reduce the number of weapons aimed at one another. Between 1985 and 1990 the cold war was brought to a close

  16. SI units in radiation protection

    International Nuclear Information System (INIS)

    Herrmann, D.

    1976-10-01

    In the field of radiation protection all hitherto used units for activity, activity concentrations, exposure, absorbed dose, and dose rates have to be replaced by SI units during the next years. For this purpose graphs and conversion tables are given as well as recommendations on unit combinations preferentially to be used. As to the dose equivalent, it is suggested to introduce a new special unit being 100 times greater than the rem, instead of maintaining the rem or using the gray for both absorbed dose and dose equivalent. Measures and time schedule relating to the gradual transition to SI units in measuring techniques, training, and publishing et cetera are explained. (author)

  17. SI units in radiation protection

    International Nuclear Information System (INIS)

    Jain, V.K.; Soman, S.D.

    1978-01-01

    International System of Units abbreviated as SI units has been adopted by most of the countries of the world. Following this development, the implementation of SI units has become mandatory with a transition period of about ten years. Some of the journals have already adopted the SI units and any material sent for publication to them must use only these. International Commission on Radiation Units and Measurement (ICRU) published letters in several journals including Physics in Medicine and Biology, Health Physics, British Journal of Radiology, etc. outlining the latest recommendations on SI units to elicit the reactions of scientists in the general field of radiological sciences. Reactions to the letters were numerous as can be seen in the correspondence columns of these journals for the last few years and ranged from great misgivings and apprehension to support and appreciation. SI units have also been the subject of editorial comments in several journals. On the basis of a survey of this literature, it may be said that there was general agreement on the long term advantage of SI units inspite of some practical difficulties in their use particularly in the initial stages. This report presents a review of SI units in radiological sciences with a view to familiarize the users with the new units in terms of the old. A time table for the gradual changeover to the SI units is also outlined. (auth.)

  18. SI units in biomedical dosimetry

    International Nuclear Information System (INIS)

    Liden, K.

    1975-01-01

    The International commission on radiation units and measurements (ICRU), during the period from 1953 to 1962 presented its definitions of the quantities absorbed dose, exposure, activity, and dose equivalent and the corresponding special units the rad, the roentgen, the curie, and the rem. At the same time an international practical system of units was developed, Le Systeme International d'Unites (SI). It was adopted by the 11th Conference Generale des Poids et Mesures (CGPM) in 1960 and is now officially introduced in almost all countries. The general implementation of the SI means difficulties for the future use of the special radiation units, because the numerical factors involved prevent their adoption as SI units. In view of this, and after having sampled the opinion in the radiological field, the ICRU prepared a Statement on Units in July, 1974 which was forwarded to the Comite International des Poids et Mesures (CIPM) and its Comite Consultatif des Unites (CCU) for consideration. As a result of this statement the CIPM has now proposed, that the 15rh CGPM adopt special names for two SI units, namely the becquerel, symbol Bq, for the unit of activity of radionuclides equal to the reciprocal second, s 1- , and the gray, symbol Gy, for the unit of absorbed dose equal to the joule per kilogram, J/kg. The 15th CGPM will consider this matter in May, 1975. (author)

  19. [United theory of aging].

    Science.gov (United States)

    Trubitsyn, A G

    2012-01-01

    In attempts to develop a means of life prolongation the humankind has created more than three hundred theories of the aging; each of them offers the original cause of aging. However, none of them has given practical result by now. The majority of the theories have now only historical interest. There are several different theories that are mainly under consideration currently. They are based on reliable, proven evidence: the free radical theory, the protein error theory, the replicative senescence theory, the theory of reparation weakening, the immunological theory, several versions of neuroendocrinal theories, and programmed aging theory. The theory presented here is based on conception that the life as the phenomenon represents many of the interconnected physical and chemical processes propelled by energy of the mitochondrial bioenergetical machine. Gradual degradation of all vital processes is caused by the programmed decrease in level of bioenergetics. This theory unites all existing theories of aging constructed on authentic facts: it is shown, that such fundamental phenomena accompanying aging process as the increase in level of reactive oxygen species (ROS), the decrease in the general level of protein synthesis, the limitation of cellular dividing (Haiflick limit), decrease in efficiency of reparation mechanisms are caused by bioenergetics attenuation. Each of these phenomena in turn generates a number of harmful secondary processes. Any of the theories bases on one of these destructive phenomena or their combination. Hence, each of them describes one of sides of process of the aging initially caused by programmed decrease of level of bioenergetics. This united theory gives the chance to understand the nature of aging clock and explains a phenomenon of increase in longevity at the condition of food restriction. Failures of attempts to develop means from aging are explained by that the manipulations with the separate secondary phenomena of attenuation of

  20. Verification and uncertainty evaluation of HELIOS/MASTER nuclear design system

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jae Seung; Kim, J. C.; Cho, B. O. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    A nuclear design system HELIOS/MASTER was established and core follow calculations were performed for Yonggwang Unit 1 cycles 1 through 7 and Yonggwang Unit 3 cycles 1 through 2. The accuracy of HELIOS/MASTER system was evaluated by estimations of uncertainties of reactivity and peaking factors and by comparisons of the maximum differences of isothermal temperature coefficient, inverse boron worth and control rod worth with the CASMO-3/MASTER uncertainties. The reactivity uncertainty was estimated by 362 pcm, and the uncertainties of three-dimensional, axially integrated radial, and planar peaking factors were evaluated by 0.048, 0.034, and 0.044 in relative power unit, respectively. The maximum differences of isothermal temperature coefficient, inverse boron worth and control rod worth were within the CASMO-3/MASTER uncertainties. 17 refs., 17 figs., 10 tabs. (Author)

  1. United Kingdom position paper

    International Nuclear Information System (INIS)

    1983-01-01

    In any system employing liquid sodium as a coolant, large heat transfer coefficients exist between the metal structure containing the coolant, and the coolant itself. Any rapidly varying temperatures, either space wise or time wise, in the sodium are readily transmitted to the surrounding metal structure, resulting in the generation of appreciable thermal stresses within these structures. In particular, the phenomenon of thermal stratification in the sodium coolant has the potential to induce unacceptable thermal stresses throughout the system. With respect to the present U.K. fast reactor design, a large programme of work in connection with the thermal hydraulic aspects of the plant is in hand. This programme is being undertaken as a joint effort by the National Nuclear Corporation, the United Kingdom Atomic Energy Authority, and the Central Electricity Generating Board. Work is in progress both to identify the areas of the system that will be susceptible to, and to ensure that the design is capable of successfully withstanding any thermal stratification effects. The production of stratification phenomena depends both upon the design and the operation of the reactor system. These are briefly described below. Areas where thermal stratification effects exist are then identified and the programme of work associated with each area is outlined

  2. Intensive Care Unit Delirium

    Directory of Open Access Journals (Sweden)

    Yongsuk Kim

    2015-05-01

    Full Text Available Delirium is described as a manifestation of acute brain injury and recognized as one of the most common complications in intensive care unit (ICU patients. Although the causes of delirium vary widely among patients, delirium increases the risk of longer ICU and hospital length of stay, death, cost of care, and post-ICU cognitive impairment. Prevention and early detection are therefore crucial. However, the clinical approach toward delirium is not sufficiently aggressive, despite the condition’s high incidence and prevalence in the ICU setting. While the underlying pathophysiology of delirium is not fully understood, many risk factors have been suggested. As a way to improve delirium-related clinical outcome, high-risk patients can be identified. A valid and reliable bedside screening tool is also needed to detect the symptoms of delirium early. Delirium is commonly treated with medications, and haloperidol and atypical antipsychotics are commonly used as standard treatment options for ICU patients although their efficacy and safety have not been established. The approaches for the treatment of delirium should focus on identifying the underlying causes and reducing modifiable risk factors to promote early mobilization.

  3. Mobile contingency unit

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Sergio O. da; Magalhaes, Milton P. de [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Junqueira, Rodrigo A.; Torres, Carlos A.R. [PETROBRAS Transporte S/A (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    This paper is aimed at presenting what is already a reality in TRANSPETRO in the area covered by OSBRA, a pipeline that carries by-products to the Mid-West region of Brazil. In order to meet the needs of covering occasional accidents, TRANSPETRO counts on a standardized system of emergency management. It is a great challenge to secure an efficient communication along the 964 km of extension, considering that there are shadow zones where it is not possible to use conventional means of communication such as mobile telephony and internet. It was in this context that the Mobile Contingency Unit Via Satellite - MCU was developed, to extend the communication facilities existing in fixed installations to remote places, mainly the pipeline right of ways. In case of emergency, simulation and work in the pipeline right of way, MCU is fully able to provide the same data, voice, closed-circuit TV and satellite video conference facilities that are available in any internal area of the PETROBRAS system. (author)

  4. Biobank Report: United Kingdom.

    Science.gov (United States)

    Kaye, Jane; Bell, Jessica; Briceno, Linda; Mitchell, Colin

    2016-03-01

    The United Kingdom is a leader in genomics research, and the presence of numerous types of biobanks and the linking of health data and research within the UK evidences the importance of biobank-based research in the UK. There is no biobank-specific law in the UK and research on biobank materials is governed by a confusing set of statutory law, common law, regulations, and guidance documents. Several layers of applicable law, from European to local, further complicate an understanding of privacy protections. Finally, biobanks frequently contain data in addition to the samples; the legal framework in the UK generally differentiates between data and samples and the form of the data affects the applicability of legal provisions. Biobanks must be licensed by the Human Tissue Authority; certain projects must be reviewed by Research Ethics Committees, and all projects are encouraged to be reviewed by them. Data Access Committees in biobanks are also common in the UK. While this confusing array of legal provisions leaves privacy protections in biobanking somewhat unclear, changes at the EU level may contribute to harmonization of approaches to privacy. © 2016 American Society of Law, Medicine & Ethics.

  5. The United Kingdom

    International Nuclear Information System (INIS)

    Croft, S.; Williams, P.

    1991-01-01

    The possession of nuclear weapons by the United Kingdom has long been a controversial issue in British politics, and among historians and strategists. Part of the controversy has revolved around questions of motivation. Why did the British Government under Prime Minister Clement Attlee develop nuclear weapons? Why have successive British governments maintained and, in fact, modernized the national nuclear force? This paper reports that a frequent response to these questions is to place the issue of the acquisition of nuclear weapons by the UK into a post-colonial context. In the nineteenth and early twentieth centuries, Britain was a great power with global assets and commitments. After the Empire was reduced in size and importance, however, and eventually swept away, Britain could not longer claim to be a superpower in any modern sense. Nevertheless, it is suggested, British policy makers had developed a foreign policy based upon certain assumptions about Britain's position and power and they were reluctant to relinquish these assumptions. Furthermore, it is contended, the decision to develop nuclear weapons was taken to reinforce what were the pretensions of a medium power, and the continued obsession of successive British governments with nuclear weapons provides evidence that Britain has still not come to terms with its reduced role and limited influence. In short, the British infatuation with nuclear weapons over the past 40 years is best explained in terms of concerns about status

  6. Units of rotational information

    Science.gov (United States)

    Yang, Yuxiang; Chiribella, Giulio; Hu, Qinheping

    2017-12-01

    Entanglement in angular momentum degrees of freedom is a precious resource for quantum metrology and control. Here we study the conversions of this resource, focusing on Bell pairs of spin-J particles, where one particle is used to probe unknown rotations and the other particle is used as reference. When a large number of pairs are given, we show that every rotated spin-J Bell state can be reversibly converted into an equivalent number of rotated spin one-half Bell states, at a rate determined by the quantum Fisher information. This result provides the foundation for the definition of an elementary unit of information about rotations in space, which we call the Cartesian refbit. In the finite copy scenario, we design machines that approximately break down Bell states of higher spins into Cartesian refbits, as well as machines that approximately implement the inverse process. In addition, we establish a quantitative link between the conversion of Bell states and the simulation of unitary gates, showing that the fidelity of probabilistic state conversion provides upper and lower bounds on the fidelity of deterministic gate simulation. The result holds not only for rotation gates, but also to all sets of gates that form finite-dimensional representations of compact groups. For rotation gates, we show how rotations on a system of given spin can simulate rotations on a system of different spin.

  7. Hanford Site Waste management units report

    International Nuclear Information System (INIS)

    1992-01-01

    This report summarizes the operable units in several areas of the Hanford Site Waste Facility. Each operable unit has several waste units (crib, ditch, pond, etc.). The operable units are summarized by describing each was unit. Some of the descriptions are unit name, unit type, waste category start data, site description, etc. The descriptions will vary for each waste unit in each operable unit and area of the Hanford Site

  8. Judicial Process, Grade Eight. Resource Unit (Unit V).

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This resource unit, developed by the University of Minnesota's Project Social Studies, introduces eighth graders to the judicial process. The unit was designed with two major purposes in mind. First, it helps pupils understand judicial decision-making, and second, it provides for the study of the rights guaranteed by the federal Constitution. Both…

  9. The Executive Process, Grade Eight. Resource Unit (Unit III).

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This resource unit, developed by the University of Minnesota's Project Social Studies, introduces eighth graders to the executive process. The unit uses case studies of presidential decision making such as the decision to drop the atomic bomb on Hiroshima, the Cuba Bay of Pigs and quarantine decisions, and the Little Rock decision. A case study of…

  10. United States mineral resources

    Science.gov (United States)

    Brobst, Donald A.; Pratt, Walden P.

    1973-01-01

    650 of the U.S. Bureau of Mines) ; indeed, we regard that book and the present volume as being complementary. In the examination of the geologic possibilities for finding new deposits-in many respects the principal innovative contributions of this volume-we asked the authors to frankly apply the limits of their ingenuity and not only to summarize current theories but also to express their own intuitive ideas, however speculative and unconventional they may seem, that have come from years of study devoted to the origin of mineral deposits. Readers will see that some authors have speculated more courageously than others. In any case, we believe readers will find all the chapters interesting, and many stimulating; and a few we believe can be frankly characterized as intellectually exciting. Most chapters include a section on prospecting techniques, and a summary of geologic or related problems on which the authors believe research might be most fruitful in the continuing efforts to find new resources. An integral part of the book is the bibliographic material cited at the conclusion of each chapter, in lieu of repetition of detailed descriptions already in print. Index and "spot" maps are not included in most chapters because they are available elsewhere, and in many cases with more detail than could possibly be included here. Maps showing the distribution of known deposits of many commodities in the United States are available in the Mineral Resource (MR) map series of the U.S. Geological Survey and in the National Atlas of the United States. The first three chapters deal not with resources of specific commodities but with general information that is pertinent to the study of mineral resources. In the introductory chapter we discuss the purposes of the book, the distinctions between reserves and various categories of resources, and some general conclusions drawn from our view of the book in its entirety. In the second chapter V. E. McKelvey discusses the problems of

  11. Fatigue of Concrete Armour Units

    DEFF Research Database (Denmark)

    Sørensen, N. B.; Burcharth, H. F.; Liu, Z.

    1995-01-01

    In the present article fatigue as a possible reason for failure of Dolosse armour units made of plain concrete is discussed.......In the present article fatigue as a possible reason for failure of Dolosse armour units made of plain concrete is discussed....

  12. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  13. Imagine There's No Carnegie Unit

    Science.gov (United States)

    Klevgaard, Janine

    2013-01-01

    This article describes how the Alberta Education High School Flexibility Enhancement Pilot Project allowed 16 high schools in Alberta, Canada, to remove the restrictions of the Carnegie unit, the seat time per credit requirement that has been widely used since 1906. The two purposes of the project were to determine whether the Carnegie unit should…

  14. Definitions of Quantities and Units.

    Science.gov (United States)

    Spurgin, C. B.

    1983-01-01

    Compares various methods of defining derived quantities, arguing for a definitional formula using base or fundamental units in a word equation, or symbol-equations with the symbols explained. Suggests that fundamental units be defined operationally or left regarded as intuitive as in the case of length and time. (JM)

  15. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  16. Edison Home Community Study Unit.

    Science.gov (United States)

    Lee County School District, Ft. Myers, FL. Dept. of Environmental Education and Instructional Development Services.

    History is not merely events that occurred in the past. The past has influenced the present, as the present will influence the future. The purpose of this community study unit is to provide fourth grade students with an opportunity to investigate some of the history of Lee County, Florida. The unit's focus is on Thomas Edison, who built a home in…

  17. 7 CFR 1160.104 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1160.104 Section 1160.104 Agriculture... Definitions § 1160.104 United States. United States means the 48 contiguous states in the continental United States and the District of Columbia, except that United States means the 50 states of the United States...

  18. United States panel presentations

    International Nuclear Information System (INIS)

    Beyea, J.

    1990-01-01

    Before I begin I have to make a disclaimer. That is that I am going to be talking about public perception because I think that is very important. But I do not want to give the impression that I think the public is wrong. I happen to agree with the public's perception of nuclear power, and I want to make that clear. I do not like the current generation of nuclear plants as I have made clear in many statements that I have made. On the other hand, in the long term, I feel that we have only two choices on the supply side, and that is nuclear power and solar electricity. And although I think solar electricity has the best chance, I am realistic enough to know that technologies do not always work the way I want. And so I think it is necessary to have at least some kind of nuclear option available. On the other hand, I do not think just any kind of nuclear technology will do. I want to talk to you about the conditions that I think you have to take into account when you try to design reactors that are publicly acceptable. I look at this as an insurance policy. Again, I do not want to be misquoted: I think nuclear power should be considered as an insurance policy, not as our first line of defense. Having made those disclaimers, what we need to do is set out a problem statement. The problem statement I set out is, 'How could one design and demonstrate a nuclear reactor that would regain public confidence in the United States, if one chose to do that?' By regaining confidence, I mean regaining sufficient confidence to site reactors at a number of locations. It is a pretty heavy task because the public cannot judge the technical issues. They have to judge the players by their characters and their histories, just as the way we calibrate anyone that knows things that we do not. I have three theses that I think are crucial. The first is that people do not believe in the claims of advocates, of any point of view, not just nuclear power, once the advocates have been proved wrong on

  19. Development of Megawatt Demand Setter for Plant Operating Flexibility

    International Nuclear Information System (INIS)

    Kim, Se Chang; Hah, Yeong Joon; Song, In Ho; Lee, Myeong Hun; Chang, Do Ik; Choi, Jung In

    1993-05-01

    The Conceptual design of the Megawatt Demand Setter (MDS) is presented for the Korean Standardized Nuclear Power Plant. The MDS is a digital supervisory limitation system. The MDS assures that the plant does not exceed the operating limits by regulating the plant operations through monitoring the operating margins of the critical parameters. MDS is aimed at increasing the operating flexibility which allow the nuclear plant to meet the grid demand in very efficient manner. It responds to the grid demand without penalizing plant availability by limiting the load demand when the operating limits are approached or violated. MDS design concepts were tested using simulation responses of Yonggwang Units 3, 4. The design of the Yonggwang Units 3, 4 would be used as a reference which designs of Korean Standardized Nuclear Power Plants would be based upon. The simulation results illustrate that the MDS can be used to improve operating flexibility. (Author)

  20. The United Kingdom: Issues for the United States

    National Research Council Canada - National Science Library

    Archick, Kristin

    2007-01-01

    ...; and more recently, from the UK's strong support in countering terrorism and confronting Iraq. The United States and Britain also share a mutually beneficial trade and economic relationship, and are each other's biggest foreign direct investors...

  1. A functional intranet for the United States Coast Guard Unit

    OpenAIRE

    Hannah, Robert Todd.

    1998-01-01

    Approved for public release; distribution in unlimited. This thesis describes the complete development process of a friendly functional Intranet for an operational United States Coast Guard (USCG) electronic Support Unit (ESU) in Alameda, California. The final product is suitable for immediate use. It may also be used as a prototype for future Intranet development efforts. The methodology used to develop a finished, working product provides the core subject matter for this thesis. The disc...

  2. Development of diagnostic mammography unit

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, M.; Muraki, T.; Kitade, K. (Toshiba Corp., Kawasaki, Kanagawa (Japan))

    1981-07-01

    The mortality from breast cancer is gradually increasing year after year. Accordingly, it is eagerly desired that X-ray diagnosis information be obtainable with higher accuracy and ease for early detection of the disease. Meeting this demand, development has been made of a 2 x magnification mammography unit (Model MGU-01) capabel of minutely depicting microcalcifications with a size of 150 ..mu..m or thereabout and the peripheral condition of a mammary abscess. The background of the development, the substance of the unit and the examination made of the unit are described here.

  3. Development of diagnostic mammography unit

    International Nuclear Information System (INIS)

    Matsubara, Mitsuyoshi; Muraki, Takeshi; Kitade, Kooichi

    1981-01-01

    The mortality from breast cancer is gradually increasing year after year. Accordingly, it is eagerly desired that X-ray diagnosis information be obtainable with higher accuracy and ease for early detection of the disease. Meeting this demand, development has been made of a 2 x magnification mammography unit (Model MGU-01) capabel of minutely depicting microcalcifications with a size of 150 μm or thereabout and the peripheral condition of a mammary abscess. The background of the development, the substance of the unit and the examination made of the unit are described here. (author)

  4. Ad valorem versus unit taxes

    DEFF Research Database (Denmark)

    Schröder, Philipp J.H.; Sørensen, Allan

    2010-01-01

    a general equilibrium monopolistic competition model with heterogeneous firms and intra-industry reallocations. We show that the welfare superiority of ad valorem over unit taxes under imperfect competition is not only preserved but amplified. The additional difference between the tools arises because unit...... taxes distort relative prices, which in turn reduces average industry productivity through reallocations (the survival and increased market share of lower productivity firms). Importantly, numerical solutions of the model reveal that the relative welfare loss from using the unit tax increases...

  5. Design of Dolos Armour Units

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Zhou

    1993-01-01

    The slender, complex types of armour units, such as Tetrapods and Dolosse are widely used. Many of the recent failures are such rubble mound breakwaters revealed that there is an imbalance between strength (structural integrity) of the units and the hydraulic stability (resistance to displacements......) of the armour layers. The paper deals only with dolos armour and presents the first design diagrammes and formulae where stresses from static, quasistatic and impact loads are implemented as well as the hydraulic stability. The dolos is treated as a multi shape unit where the thickness can be adjusted...

  6. An identification of potential new herbicides for short rotation coppice (Task 4). Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This report summarises the findings of a project to identify potential new herbicides and their suitability for weed control in commercial short rotation coppice (SRC) crops, and to establish the safety of the crops. The arrangements for the use of 'off-label' pesticides, which are permitted for use on other crops, on SRC are discussed along with the importance of the use of laboratory pot trials and field trials. Several herbicides are proposed for larger scale field trials.

  7. Probabilistic safety goals for nuclear power plants; Phases 2-4. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bengtsson, L.; Knochenhauer, M. (Scandpower AB (Sweden)); Holmberg, J.-E.; Rossi, J. (VTT Technical Research Centre of Finland (Finland))

    2011-05-15

    Safety goals are defined in different ways in different countries and also used differently. Many countries are presently developing them in connection to the transfer to risk-informed regulation of both operating nuclear power plants (NPP) and new designs. However, it is far from self-evident how probabilistic safety criteria should be defined and used. On one hand, experience indicates that safety goals are valuable tools for the interpretation of results from a probabilistic safety assessment (PSA), and they tend to enhance the realism of a risk assessment. On the other hand, strict use of probabilistic criteria is usually avoided. A major problem is the large number of different uncertainties in a PSA model, which makes it difficult to demonstrate the compliance with a probabilistic criterion. Further, it has been seen that PSA results can change a lot over time due to scope extensions, revised operating experience data, method development, changes in system requirements, or increases of level of detail, mostly leading to an increase of the frequency of the calculated risk. This can cause a problem of consistency in the judgments. This report presents the results from the second, third and fourth phases of the project (2007-2009), which have dealt with providing guidance related to the resolution of some specific problems, such as the problem of consistency in judgement, comparability of safety goals used in different industries, the relationship between criteria on different levels, and relations between criteria for level 2 and 3 PSA. In parallel, additional context information has been provided. This was achieved by extending the international overview by contributing to and benefiting from a survey on PSA safety criteria which was initiated in 2006 within the OECD/NEA Working Group Risk. The results from the project can be used as a platform for discussions at the utilities on how to define and use quantitative safety goals. The results can also be used by safety authorities as a reference for risk-informed regulation. The outcome can have an impact on the requirements on PSA, e.g., regarding quality, scope, level of detail, and documentation. Finally, the results can be expected to support on-going activities concerning risk-informed applications. The project provides a comprehensive state-of-the-art description and has contributed to clarifying the history of safety goals both nationally and internationally, the concepts involved in defining and applying probabilistic safety criteria, and the international status and trends in general. It has identified critical issues and the main problem areas. Finally, the project provides useful recommendations and guidance on the definition and application of criteria. Furthermore, the project makes it possible to define criteria stringently, improving the possibilities of argumentation on safety. Generally, this supports efficient use of criteria, yielding more useful PSA results. In this connection, the introduction of ALARP type criteria is judged to provide a very useful way of balancing stringency with the necessary flexibility. There is a possibility of making more active use of lower level criteria. This makes the connection to defence in depth more evident, and opens the perspective of increased control of defence in depth by use of probabilistic methods, including the use as design tools. There is an opportunity for comparison of risk of different NPPs, as well as of comparison of NPP risk with other risks in society. This is judged to provide an opportunity for improved communication on risks with non-PSA experts and with the public in general. However, a necessary condition for meaningful comparisons is to agree on the scope of PSA and methods applied. Obviously, there will also be challenges in the future definition and application of probabilistic safety criteria. These include very general aspects, such as the interpretation of the probability, quality aspects of PSA, and the definition of meaningful and consistent risk criteria for different usages. The need and usefulness of subsidiary criteria has been stressed in the project, but there is obviously also a challenge in defining a relevant set of criteria on different levels. Defining criteria for L(E)RF is complex, especially if release criteria are defined as subsidiary for societal and individual risk. Finally, it will be a challenge to develop coherent application procedures relative to the criteria defined. (Author)

  8. ESF [Exploratory Shaft Facility] impact evaluation report: Volume 4: Final report

    International Nuclear Information System (INIS)

    1985-08-01

    The objective of this Project Information is to present information compiled during a cursory search to determine the number of US evaporite mines (trona, salt and potash) that are classified as gassy under 30 CFR 57.21. Attention was directed in particular toward the degree of compliance, and was restricted to only those mines employing a room and pillar system of mining. The majority of evaporite mines classified gassy operate under approved modifications. None of the active bedded salt mines are classified gassy. Two of the five active domal salt mines are gassy, as well as one of the six potash mines. All trona mines operate under a gassy classification. The M-K Design Group recommends that the current MSHA regulations be used for the conceptual design as mandated by the DOE Functional Design Criteria for High-Level Nuclear Waste Repository in Salt. 13 refs., 1 tab

  9. Probabilistic Safety Goals for Nuclear Power Plants; Phases 2-4 / Final Report

    International Nuclear Information System (INIS)

    Bengtsson, Lisa; Knochenhauer, Michael; Holmberg, Jan-Erik; Rossi, Jukka

    2011-05-01

    The outcome of a probabilistic safety assessment (PSA) for a nuclear power plant is a combination of qualitative and quantitative results. Quantitative results are typically presented as the Core Damage Frequency (CDF) and as the frequency of an unacceptable radioactive release. In order to judge the acceptability of PSA results, criteria for the interpretation of results and the assessment of their acceptability need to be defined. Safety goals are defined in different ways in different countries and also used differently. Many countries are presently developing them in connection to the transfer to risk-informed regulation of both operating nuclear power plants (NPP) and new designs. However, it is far from self-evident how probabilistic safety criteria should be defined and used. On one hand, experience indicates that safety goals are valuable tools for the interpretation of results from a probabilistic safety assessment (PSA), and they tend to enhance the realism of a risk assessment. On the other hand, strict use of probabilistic criteria is usually avoided. A major problem is the large number of different uncertainties in a PSA model, which makes it difficult to demonstrate the compliance with a probabilistic criterion. Further, it has been seen that PSA results can change a lot over time due to scope extensions, revised operating experience data, method development, changes in system requirements, or increases of level of detail, mostly leading to an increase of the frequency of the calculated risk. This can cause a problem of consistency in the judgments. The first phase of the project (2006) provided a general description of the issue of probabilistic safety goals for nuclear power plants, of important concepts related to the definition and application of safety goals, and of experiences in Finland and Sweden. The second, third and fourth phases (2007-2009) have been concerned with providing guidance related to the resolution of some of the problems identified, such as the problem of consistency in judgement, comparability of safety goals used in different industries, the relationship between criteria on different levels, and relations between criteria for level 2 and 3 PSA. In parallel, additional context information has been provided. This was achieved by extending the international overview by contributing to and benefiting from a survey on PSA safety criteria which was initiated in 2006 within the OECD/NEA Working Group Risk. Finally, a separate report has been issued providing general guidance concerning the formulation, application and interpretation of probabilistic criteria. The results from the project can be used as a platform for discussions at the utilities on how to define and use quantitative safety goals. The results can also be used by safety authorities as a reference for risk-informed regulation. The outcome can have an impact on the requirements on PSA, e.g., regarding quality, scope, level of detail, and documentation. Finally, the results can be expected to support on-going activities concerning risk-informed applications

  10. Probabilistic safety goals for nuclear power plants; Phases 2-4. Final report

    International Nuclear Information System (INIS)

    Bengtsson, L.; Knochenhauer, M.; Holmberg, J.-E.; Rossi, J.

    2011-05-01

    Safety goals are defined in different ways in different countries and also used differently. Many countries are presently developing them in connection to the transfer to risk-informed regulation of both operating nuclear power plants (NPP) and new designs. However, it is far from self-evident how probabilistic safety criteria should be defined and used. On one hand, experience indicates that safety goals are valuable tools for the interpretation of results from a probabilistic safety assessment (PSA), and they tend to enhance the realism of a risk assessment. On the other hand, strict use of probabilistic criteria is usually avoided. A major problem is the large number of different uncertainties in a PSA model, which makes it difficult to demonstrate the compliance with a probabilistic criterion. Further, it has been seen that PSA results can change a lot over time due to scope extensions, revised operating experience data, method development, changes in system requirements, or increases of level of detail, mostly leading to an increase of the frequency of the calculated risk. This can cause a problem of consistency in the judgments. This report presents the results from the second, third and fourth phases of the project (2007-2009), which have dealt with providing guidance related to the resolution of some specific problems, such as the problem of consistency in judgement, comparability of safety goals used in different industries, the relationship between criteria on different levels, and relations between criteria for level 2 and 3 PSA. In parallel, additional context information has been provided. This was achieved by extending the international overview by contributing to and benefiting from a survey on PSA safety criteria which was initiated in 2006 within the OECD/NEA Working Group Risk. The results from the project can be used as a platform for discussions at the utilities on how to define and use quantitative safety goals. The results can also be used by safety authorities as a reference for risk-informed regulation. The outcome can have an impact on the requirements on PSA, e.g., regarding quality, scope, level of detail, and documentation. Finally, the results can be expected to support on-going activities concerning risk-informed applications. The project provides a comprehensive state-of-the-art description and has contributed to clarifying the history of safety goals both nationally and internationally, the concepts involved in defining and applying probabilistic safety criteria, and the international status and trends in general. It has identified critical issues and the main problem areas. Finally, the project provides useful recommendations and guidance on the definition and application of criteria. Furthermore, the project makes it possible to define criteria stringently, improving the possibilities of argumentation on safety. Generally, this supports efficient use of criteria, yielding more useful PSA results. In this connection, the introduction of ALARP type criteria is judged to provide a very useful way of balancing stringency with the necessary flexibility. There is a possibility of making more active use of lower level criteria. This makes the connection to defence in depth more evident, and opens the perspective of increased control of defence in depth by use of probabilistic methods, including the use as design tools. There is an opportunity for comparison of risk of different NPPs, as well as of comparison of NPP risk with other risks in society. This is judged to provide an opportunity for improved communication on risks with non-PSA experts and with the public in general. However, a necessary condition for meaningful comparisons is to agree on the scope of PSA and methods applied. Obviously, there will also be challenges in the future definition and application of probabilistic safety criteria. These include very general aspects, such as the interpretation of the probability, quality aspects of PSA, and the definition of meaningful and consistent risk criteria for different usages. The need and usefulness of subsidiary criteria has been stressed in the project, but there is obviously also a challenge in defining a relevant set of criteria on different levels. Defining criteria for L(E)RF is complex, especially if release criteria are defined as subsidiary for societal and individual risk. Finally, it will be a challenge to develop coherent application procedures relative to the criteria defined. (Author)

  11. Human factor tests on car demonstrator Deliverable no D6.4. Final draft

    NARCIS (Netherlands)

    Schindhelm, R.; Gelau, C.; Montanari, R.; Morreale, D.; Deregibus, E.; Hoedemaeker, D.M.; Ridder, S. de; Piamonte, P.

    2003-01-01

    The main objective of the COMUNICAR on-road tests was to evaluate the effect on driver’s workload, acceptance, system usability and driving performance when using the COMUNICAR multimedia HMI which integrates innovative I/O devices and the Information Manager (IM). All these criteria are expected to

  12. Regional demand forecasting and simulation model: user's manual. Task 4, final report

    Energy Technology Data Exchange (ETDEWEB)

    Parhizgari, A M

    1978-09-25

    The Department of Energy's Regional Demand Forecasting Model (RDFOR) is an econometric and simulation system designed to estimate annual fuel-sector-region specific consumption of energy for the US. Its purposes are to (1) provide the demand side of the Project Independence Evaluation System (PIES), (2) enhance our empirical insights into the structure of US energy demand, and (3) assist policymakers in their decisions on and formulations of various energy policies and/or scenarios. This report provides a self-contained user's manual for interpreting, utilizing, and implementing RDFOR simulation software packages. Chapters I and II present the theoretical structure and the simulation of RDFOR, respectively. Chapter III describes several potential scenarios which are (or have been) utilized in the RDFOR simulations. Chapter IV presents an overview of the complete software package utilized in simulation. Chapter V provides the detailed explanation and documentation of this package. The last chapter describes step-by-step implementation of the simulation package using the two scenarios detailed in Chapter III. The RDFOR model contains 14 fuels: gasoline, electricity, natural gas, distillate and residual fuels, liquid gases, jet fuel, coal, oil, petroleum products, asphalt, petroleum coke, metallurgical coal, and total fuels, spread over residential, commercial, industrial, and transportation sectors.

  13. Tax_Units_2011_Final

    Data.gov (United States)

    Kansas Data Access and Support Center — The Statewide GIS Tax Unit boundary file was created through a collaborative partnership between the State of Kansas Department of Revenue Property Valuation...

  14. Integrated Ground Operations Demonstration Units

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of the AES Integrated Ground Operations Demonstration Units (IGODU) project is to demonstrate cost efficient cryogenic operations on a relevant...

  15. Renewable energies in United Kingdom

    International Nuclear Information System (INIS)

    Baize, T.

    1993-01-01

    An evaluation of research and development policy in United Kingdom on renewable energy sources is presented with economical studies (short or long term profitability), engaged programs and electric production. (A.B.). refs. tabs

  16. NCHS - Injury Mortality: United States

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset describes injury mortality in the United States beginning in 1999. Two concepts are included in the circumstances of an injury death: intent of injury...

  17. Unit 06 - Sampling the World

    OpenAIRE

    Unit 06, CC in GIS; Parson, Charles; Nyerges, Timothy

    1990-01-01

    This unit begins the section on data acquisition by looking at how the infinite complexity of the real world can be discretized and sampled. It considers sampling techniques and associated issues of accuracy and standards.

  18. Environmental Control Unit Harness Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Testing four new Environmental Control Unit Harnesses for improved user comfort during SCAPE operations. Phase I, testing in a lab environment, Phase II will continue testing the best candidates in a field environment.

  19. 77 FR 48542 - United States

    Science.gov (United States)

    2012-08-14

    ... litigation.'' United States v. Armour and Co., 402 U.S. 673, 681 (1971). Section 5 of the Clayton Act... relief in consent judgment that contained recitals in which defendants asserted their innocence); Armour...

  20. Dedicated education unit: student perspectives.

    Science.gov (United States)

    Nishioka, Vicki M; Coe, Michael T; Hanita, Makoto; Moscato, Susan R

    2014-01-01

    The study compared students' perceptions of their clinical learning experiences in a dedicated education unit (DEU) with their experiences in traditional clinical education. Unlike traditional academic-instructor models, expert nurses in the DEU provide clinical education to students with faculty support. This repeated measures design used student surveys, supplemented by focus group data. Students were more likely to agree that their clinical learning experience was high quality and they had a consistent mentoring relationship during DEU rotations. Students also reported the quality of the unit's learning environment, the leadership style of the nurse manager, and the nursing care on the unit was more favorable in DEUs than traditional units. Consistent with their changed role in DEUs, faculty members were less active in helping students integrate theory and practice. These findings provide additional evidence of the value that the DEU model contributes to high-quality clinical education.

  1. United States Strategy for Mexico

    National Research Council Canada - National Science Library

    Centner, Robert C

    2005-01-01

    The security and stability of Mexico is of national interest to the United States, and a strong, effective alliance between the two countries is pivotal to our national defense strategy and economic prosperity...

  2. Architecture of nuclear power units

    International Nuclear Information System (INIS)

    Malaniuk, B.

    1981-01-01

    Nuclear units with circulation cooling using cooling towers are dominating points of the landscape. The individual cooling towers or pairs of cooling towers should be situated in the axes of double units and should also linearly be arranged, rhythmically in the respective zone. Examples are shown of the architectural designs of several nuclear power plants in the USA, the UK, the USSR, France, the FRG and Italy. (H.S.)

  3. Management of planned unit outages

    International Nuclear Information System (INIS)

    Brune, W.

    1984-01-01

    Management of planned unit outages at the Bruno Leuschner Nuclear Power Plant is based on the experience gained with Soviet PWR units of the WWER type over a period of more than 50 reactor-years. For PWR units, planned outages concentrate almost exclusively on annual refuellings and major maintenance of the power plant facilities involved. Planning of such major maintenance work is based on a standardized basic network plan and a catalogue of standardized maintenance and inspection measures. From these, an overall maintenance schedule of the unit and partial process plans of the individual main components are derived (manually or by computer) and, in the temporal integration of major maintenance at every unit, fixed starting times and durations are determined. More than 75% of the maintenance work at the Bruno Leuschner Nuclear Power Plant is carried out by the plant's own maintenance personnel. Large-scale maintenance of every unit is controlled by a special project head. He is assisted by commissioners, each of whom is responsible for his own respective item. A daily control report is made. The organizational centre is a central office which works in shifts around the clock. All maintenance orders and reports of completion pass through this office; thus, the overall maintenance schedule can be corrected daily. To enforce the proposed operational strategy, suitable accompanying technical measures are required with respect to effective facility monitoring and technical diagnosis, purposeful improvement of particularly sensitive components and an increase in the effectiveness of maintenance work by special technologies and devices. (author)

  4. SI units in engineering and technology

    CERN Document Server

    Qasim, S H

    2016-01-01

    SI Units in Engineering and Technology focuses on the use of the International System of Units-Systeme International d'Unités (SI). The publication first elaborates on the SI, derivation of important engineering units, and derived SI units in science and engineering. Discussions focus on applied mechanics in mechanical engineering, electrical and magnetic units, stress and pressure, work and energy, power and force, and magnitude of SI units. The text then examines SI units conversion tables and engineering data in SI units. Tables include details on the sectional properties of metals in SI units, physical properties of important molded plastics, important physical constants expressed in SI units, and temperature, area, volume, and mass conversion. Tables that show the mathematical constants, standard values expressed in SI units, and Tex count conversion are also presented. The publication is a dependable source of data for researchers interested in the use of the International System of Units-Systeme Inter...

  5. 31 CFR 800.225 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 800.225 Section 800... TAKEOVERS BY FOREIGN PERSONS Definitions § 800.225 United States. The term United States or U.S. means the United States of America, the States of the United States, the District of Columbia, and any commonwealth...

  6. Nations United: The United Nations, the United States, and the Global Campaign Against Terrorism. A Curriculum Unit & Video for Secondary Schools.

    Science.gov (United States)

    Houlihan, Christina; McLeod, Shannon

    This curriculum unit and 1-hour videotape are designed to help students understand the purpose and functions of the United Nations (UN) and explore the relationship between the United Nations and the United States. The UN's role in the global counterterrorism campaign serves as a case study for the unit. The students are asked to develop a basic…

  7. Ecological units: definitions and application.

    Science.gov (United States)

    Jax, Kurt

    2006-09-01

    Concepts of ecological units, such as population, community, and ecosystem, are at the basis of ecological theory and research and have increasingly become the focus of conservation strategies. Concepts of these units still suffer from inconsistencies and confusions over terminology. The different concepts are treated here together as a common "conceptual cluster," with similar ecological functions (roles) and similar problems in their definition and use. An analysis of the multitude of existing terms and concepts that have been developed for these units reveals that they differ with respect to at least four basic criteria: (i) the questions as to whether they are defined statistically or via a network of interactions; (ii) if their boundaries are drawn by topographical or process-related criteria; (iii) how high the required internal relationships are; and (iv) if they are perceived as "real" entities or abstractions by an observer The various definitions cannot be easily sorted into just a few types, but they can be characterized by several independent criteria. I argue that serious problems arise if the different possibilities of defining ecological units are not recognized and if the concepts are perceived as self-evident. The different concepts of ecological units should be defined and used in a philosophically informed manner I propose a dual approach to the use of ecological units. Generic meanings of the main concepts (especially population, community, and ecosystem) should be retained only as heuristically useful perspectives, while specific and "operational" definitions of the concepts as units should be developed, depending on specific purposes of their use. Some thoughts on the basic requirements for such definitions and the domains of their uses are briefly explained.

  8. United Nations Peacekeeping: Issues for Congress

    National Research Council Canada - National Science Library

    Browne, Marjorie A

    2008-01-01

    A major issue facing the United Nations, the United States, and the 110th Congress is the extent to which the United Nations has the capacity to restore or keep the peace in the changing world environment...

  9. United Nations Peacekeeping: Issues for Congress

    National Research Council Canada - National Science Library

    Browne, Marjorie A

    2007-01-01

    A major issue facing the United Nations, the United States, and the 110th Congress is the extent to which the United Nations has the capacity to restore or keep the peace in the changing world environment...

  10. Mobile units to hydro geochemistry characterization

    International Nuclear Information System (INIS)

    Gomez, P.; Martinez, B.; Turrero, M.J.

    1994-01-01

    This report shows the mobile units for hydro geochemical studies. The authors analyze the work of mobile unit and the cars that conform the unit: Sampling car and analysis car: The sampling and equipment are took into account as well

  11. United Nations and Multilateralism: Appraising USA's Unilateralism ...

    African Journals Online (AJOL)

    DrNneka

    global peace and security, as well as the survival of the United Nations. This is because ... Key Words: United Nations, multilateralism, United States, unilateralism, national interest, UN Charter ..... Lebanon, Iraq, Turkey, Egypt, Jordan, etc.

  12. UNIT COMMITMENT: A NEW TRUNCATED METHOD OF UNIT ...

    African Journals Online (AJOL)

    NIJOTECH

    Data obtained from the National Electric Power Authority (NEPA) has been used to test the efficacy of this approach. ... every unit in the system must be respected. Some of these ..... Analysis of Power System Reliability. 2.Edwin K. W, Machat, ...

  13. Photovoltaic mounting/demounting unit

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a photovoltaic arrangement comprising a photovoltaic assembly comprising a support structure defining a mounting surface onto which a photovoltaic module is detachably mounted; and a mounting/demounting unit comprising at least one mounting/demounting apparatus...... which when the mounting/demounting unit is moved along the mounting surface, causes the photovoltaic module to be mounted or demounted to the support structure; wherein the photovoltaic module comprises a carrier foil and wherein a total thickness of the photo voltaic module is below 500 muiotaeta....... The present invention further relates to an associated method for mounting/demounting photovoltaic modules....

  14. Organization of the POCT Unit.

    Science.gov (United States)

    Warade, Jayesh

    2015-03-01

    Point-of-care testing (POCT) has evolved as an important part of laboratory medicine by virtue of its compactness, portability, and the feasibility of operation by nonlaboratory personnel, where fast and accurate testing methods are a primary concern and, as a result, improving the patient care. To successfully achieve POCT quality in networks, a multidisciplinary organizational approach is required. A clearly defined organizational structure should be put in place for proper functioning and optimum utilization of each POCT unit. The POCT unit must include designated authority, responsibility, and accountability.

  15. The United Nations at 40

    International Nuclear Information System (INIS)

    1985-01-01

    The United Nations adopted a resolution expressing the hope that 1985 would mark the beginning of an era of durable and global peace and justice, social and economic development and progress and independence of all peoples. 1985 is the organization's 40th anniversary year - the United Nations Charter entered into force on 24 October 1945 - and the Assembly has chosen 'United Nations for a better world' as the anniversary theme. It also has decided to hold a brief commemorative session culminating on 24 October this year. Member States of the UN also have been urged to organize appropriate observance of the anniversary, with the widest possible participation, and to consider the creation of national committees to evaluate the contribution of the UN system over the past four decades, its continuing relevance in the current international situation, and ways in which it could be strengthened and made more effective. Among other things, the Assembly in its resolution appealed to the international mass media, both public and private, to contribute more effectively to dissemination of information on UN activities. During the commemorative session planned this October, a final document is expected to be adopted for which the Assembly has asked the Preparatory Committee for the Fortieth Anniversary of the United Nations to compose a suitable text. The Preparatory Committee had been established by the Assembly in 1983, and by December 1984, 98 countries had joined in its work, which relates to various activities

  16. Kitchen Units for the Classroom.

    Science.gov (United States)

    Illinois Univ., Urbana. Agricultural Experiment Station.

    This study is concerned with functional standards for storage of equipment, use of space, and arrangement of work centers in kitchen units for four students within a high school foods laboratory. Lists of equipment and measurements for storage areas are given for each work center. (FS)

  17. Norovirus in the United States

    Centers for Disease Control (CDC) Podcasts

    2013-09-09

    Dr. Aron Hall, a CDC epidemiologist specializing in norovirus, discusses the impact of norovirus in the United States.  Created: 9/9/2013 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 9/17/2013.

  18. Solar Renewable Energy. Teaching Unit.

    Science.gov (United States)

    Buchanan, Marion; And Others

    This unit develops the concept of solar energy as a renewable resource. It includes: (1) an introductory section (developing understandings of photosynthesis and impact of solar energy); (2) information on solar energy use (including applications and geographic limitations of solar energy use); and (3) future considerations of solar energy…

  19. Spherical Approximation on Unit Sphere

    Directory of Open Access Journals (Sweden)

    Eman Samir Bhaya

    2018-01-01

    Full Text Available In this paper we introduce a Jackson type theorem for functions in LP spaces on sphere And study on best approximation of  functions in  spaces defined on unit sphere. our central problem is to describe the approximation behavior of functions in    spaces for  by modulus of smoothness of functions.

  20. United States Navy DL Perspective

    Science.gov (United States)

    2010-08-10

    United States Navy DL Perspective CAPT Hank Reeves Navy eLearning Project Director 10 August 2010 Report Documentation Page Form ApprovedOMB No...Marine Corps (USMC) Navy eLearning Ongoing Shared with USMC, Coast Guard 9 NeL Help Site https://ile-help.nko.navy.mil/ile/ https://s-ile

  1. Victorian Era: An Interdisciplinary Unit.

    Science.gov (United States)

    Gildart, Donna Mae; And Others

    Seventh grade students studied the Victorian period using a 4-6 week interdisciplinary unit that integrated language arts, mathematics, art, science, social studies, music, home economics, parents, and business into the program. The main goals were to help students understand the importance of all curriculum subjects; comprehend how subjects are…

  2. Tractor Safety. Unit A-9.

    Science.gov (United States)

    Luft, Vernon D.; Backlund, Paul

    This document is a teacher's guide for a unit in tractor and machinery safety for college freshmen. It is intended to be used for 10 hours of instruction for freshmen who are intending to work on or around machinery. Safety hazards directly and indirectly related to many types of machinery are covered in addition to tractors. The objectives of the…

  3. Vapor generating unit blowdown arrangement

    International Nuclear Information System (INIS)

    McDonald, B.N.

    1978-01-01

    A vapor generating unit having a U-shaped tube bundle is provided with an orificed downcomer shroud and a fluid flow distribution plate between the lower hot and cold leg regions to promote fluid entrained sediment deposition in proximity to an apertured blowdown pipe

  4. Cholera in the United States

    Centers for Disease Control (CDC) Podcasts

    2011-11-08

    Anna Newton, Surveillance Epidemiologist at CDC, discusses cholera that was brought to the United States during an outbreak in Haiti and the Dominican Republic (Hispaniola).  Created: 11/8/2011 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 11/8/2011.

  5. The United Nations at 40

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1985-10-01

    The United Nations adopted a resolution expressing the hope that 1985 would mark the beginning of an era of durable and global peace and justice, social and economic development and progress and independence of all peoples. 1985 is the organization's 40th anniversary year - the United Nations Charter entered into force on 24 October 1945 - and the Assembly has chosen 'United Nations for a better world' as the anniversary theme. It also has decided to hold a brief commemorative session culminating on 24 October this year. Member States of the UN also have been urged to organize appropriate observance of the anniversary, with the widest possible participation, and to consider the creation of national committees to evaluate the contribution of the UN system over the past four decades, its continuing relevance in the current international situation, and ways in which it could be strengthened and made more effective. Among other things, the Assembly in its resolution appealed to the international mass media, both public and private, to contribute more effectively to dissemination of information on UN activities. During the commemorative session planned this October, a final document is expected to be adopted for which the Assembly has asked the Preparatory Committee for the Fortieth Anniversary of the United Nations to compose a suitable text. The Preparatory Committee had been established by the Assembly in 1983, and by December 1984, 98 countries had joined in its work, which relates to various activities.

  6. [Developments in medical units. 1915].

    Science.gov (United States)

    Fajardo-Ortiz, Guillermo

    2016-01-01

    In 1915 the political, economic, and social instability initiated the destruction of medical units; they had no administrative bases and they lacked the resources. However, needs encouraged that structures arose to meet the wounded, fractured, and traumatized, called “blood” hospitals and so-called crosses and sanitary trains.

  7. Genetic maps and physical units

    International Nuclear Information System (INIS)

    Karunakaran, V.; Holt, G.

    1976-01-01

    The relationships between physical and genetic units are examined. Genetic mapping involves the detection of linkage of genes and the measurement of recombination frequencies. The genetic distance is measured in map units and is proportional to the recombination frequencies between linked markers. Physical mapping of genophores, particularly the simple genomes of bacteriophages and bacterial plasmids can be achieved through heteroduplex analysis. Genetic distances are dependent on recombination frequencies and, therefore, can only be correlated accurately with physical unit lengths if the recombination frequency is constant throughout the entire genome. Methods are available to calculate the equivalent length of DNA per average map unit in different organisms. Such estimates indicate significant differences from one organism to another. Gene lengths can also be calculated from the number of amino acids in a specified polypeptide and relating this to the number of nucleotides required to code for such a polypeptide. Many attempts have been made to relate microdosimetric measurements to radiobiological data. For irradiation effects involving deletion of genetic material such a detailed correlation may be possible in systems where heteroduplex analysis or amino acid sequencing can be performed. The problems of DNA packaging and other functional associations within the cell in interpreting data is discussed

  8. "Mexico in Transition." Curriculum Units.

    Science.gov (United States)

    Oregon Univ., Eugene. Foreign Language Resource Center.

    These curriculum units were developed in a National Endowment for the Humanities 1994 summer seminar "Mexico in Transition." The 23 lessons are written in Spanish. Lessons are entitled: (1) "La Migracion Mexicana Vista a Traves del Cuento 'Paso del Norte' de Juan Rulfo" (Jose Jorge Armendariz); (2) "Los Grupos Indigenas de…

  9. Pentachlorophenol (PCP) sludge recycling unit

    International Nuclear Information System (INIS)

    1994-08-01

    The Guelph Utility Pole Company treats utility poles by immersion in pentachlorophenol (PCP) or by pressure treatment with chromated copper arsenate (CCA). The PCP treatment process involves a number of steps, each producing a certain amount of sludge and other wastes. In a plant upgrading program to improve processing and treatment of poles and to reduce and recycle waste, a PCP recovery unit was developed, first as an experimental pilot-scale unit and then as a full-scale unit. The PCP recovery unit is modular in design and can be modified to suit different requirements. In a recycling operation, the sludge is pumped through a preheat system (preheated by waste heat) and suspended solids are removed by a strainer. The sludge is then heated in a tank and at a predetermined temperature it begins to separate into its component parts: oil, steam, and solids. The steam condenses to water containing low amounts of light oil, and this water is pumped through an oil/water separator. The recovered oil is reused in the wood treatment process and the water is used in the CCA plant. The oil remaining in the tank is reused in PCP treatment and the solid waste, which includes small stones and wood particles, is removed and stored. By the third quarter of operation, the recovery unit was operating as designed, processing ca 10,000 gal of sludge. This sludge yielded 6,500 gal of water, 3,500 gal of oil, and ca 30 gal of solids. Introduction of the PCP sludge recycling system has eliminated long-term storage of PCP sludge and minimized costs of hazardous waste disposal. 4 figs

  10. United Nations opens gender coordinating unit for Afghanistan.

    Science.gov (United States)

    Morris, K

    1999-02-06

    The UN has created a gender coordinating unit for Afghanistan in an effort to combat some problems encountered by women and girls in the country. Reports continue to come in of women in Afghanistan being denied the right to work, to be educated, and to have access to medical care. The gap in education between men and women continues to widen as a result of edicts issued by Taliban authorities banning girls from attending formal schools and female teachers from working. The situation has grown worse since the UN and nongovernmental organizations (NGOs) withdrew international workers last year due to security concerns. Although a UN mission will travel to the country this week to discuss the return of international staff, the gender coordinating unit will for now have to work out of Islamabad, Pakistan. The unit will create guidelines for gender mainstreaming, a strategy in which mainstream policies and resource allocations are changed to reflect the principle of gender equality. Other goals include setting realistic objectives for gender activities, working with partners on pilot projects, and establishing minimum standards for best practices. MERLIN, a NGO with a primary health care program run by local staff in the Taliban-controlled province of Farah, welcomes the move.

  11. Qualification of package units; Qualifizierung von Package Units

    Energy Technology Data Exchange (ETDEWEB)

    Brombacher, M.; Walter, U. [Bayer AG, Leverkusen (Germany)

    1999-07-01

    The use of package units in pharmaceutical plants is increasing. If they are involved in the manufacture of pharmaceuticals and have an influence on the quality of the end product, the user is required to validate the processes used. Parallel to the growing demands with respect to the automation of these units, the importance of PCS equipment has increased and with this the necessity for its qualification. Experience to date shows that the manufacturer's awareness of these requirements can be heightened still further. This paper describes approaches for improving the present situation and should be interpreted not as criticism but as providing an opportunity to increase the knowledge base and work together to define solutions which satisfy the guidelines. (orig.) [German] Der Einsatz von Package Units in Pharma-Anlagen erfaehrt zunehmende Verbreitung. Wenn sie an der Herstellung von Arzneimitteln beteiligt sind und auf die Qualitaet des Endprodukts Einfluss nehmen, unterliegen sie der Validierungspflicht, die der Anwender zu gewaehrleisten hat. Entsprechend den wachsenden Anforderungen an die Automatisierung dieser Einheiten ist auch der Stellenwert der PLT-Ausruestung angestiegen und mit ihm die Notwendigkeit von deren Qualifizierung. Die bisherige Praxis zeigt, dass die Sensbilitaet der Hersteller diesen Anforderungen gegenueber noch besser entwickelt werden kann. Der Beitrag zeigt Wege auf, um die derzeitige Situation zu verbessern und sollte nicht als Kritik sondern als Chance aufgefasst werden, den Wissensstand auszugleichen und gemeinsam zu richtliniengerechten Loesungen zu kommen. (orig.)

  12. 7 CFR 1250.308 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1250.308 Section 1250.308 Agriculture... Research and Promotion Order Definitions § 1250.308 United States. United States means the 48 contiguous States of the United States of America and the District of Columbia. ...

  13. 31 CFR 598.317 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 598.317 Section 598.317 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 598.317 United States. The term United States means the United States, its territories and...

  14. 31 CFR 596.312 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 596.312 Section 596.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 596.312 United States. The term United States means the United States, including its...

  15. 31 CFR 538.314 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 538.314 Section 538.314 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 538.314 United States. The term United States means the United States, its territories and possessions...

  16. 31 CFR 543.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 543.310 Section 543.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 543.310 United States. The term United States means the United States, its territories and...

  17. 31 CFR 542.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 542.310 Section 542.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  18. 31 CFR 548.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 548.310 Section 548.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  19. 7 CFR 65.255 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false United States. 65.255 Section 65.255 Agriculture..., PEANUTS, AND GINSENG General Provisions Definitions § 65.255 United States. United States means the 50... United States. ...

  20. 31 CFR 546.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 546.310 Section 546.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....310 United States. The term United States means the United States, its territories and possessions...

  1. 31 CFR 594.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 594.313 Section 594.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 594.313 United States. The term United States means the United States, its territories and...

  2. 31 CFR 588.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 588.310 Section 588.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 588.310 United States. The term United States means the United States, its territories and...

  3. 7 CFR 1206.23 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1206.23 Section 1206.23 Agriculture... INFORMATION Mango Promotion, Research, and Information Order Definitions § 1206.23 United States. United... Rico, and the territories and possessions of the United States. ...

  4. 31 CFR 536.315 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 536.315 Section 536.315 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 536.315 United States. The term United States means the United States, its territories and...

  5. 31 CFR 544.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 544.310 Section 544.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 544.310 United States. The term United States means the United States, its...

  6. 31 CFR 592.311 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 592.311 Section 592... § 592.311 United States. The term United States, when used in the geographic sense, means the several States, the District of Columbia, and any commonwealth, territory, or possession of the United States. ...

  7. 31 CFR 545.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 545.313 Section 545.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... Definitions § 545.313 United States. The term United States means the United States, its territories and...

  8. 7 CFR 1205.23 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1205.23 Section 1205.23 Agriculture... Procedures for Conduct of Sign-up Period Definitions § 1205.23 United States. The term United States means the 50 states of the United States of America. Procedures ...

  9. 31 CFR 595.314 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 595.314 Section 595.314 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 595.314 United States. The term United States means the United States, its territories and possessions...

  10. 31 CFR 586.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 586.318 Section 586...) KOSOVO SANCTIONS REGULATIONS General Definitions § 586.318 United States. The term United States means the United States, its territories and possessions, and all areas under the jurisdiction or authority...

  11. 31 CFR 537.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 537.318 Section 537.318 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....318 United States. The term United States means the United States, its territories and possessions...

  12. 31 CFR 597.318 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 597.318 Section 597... General Definitions § 597.318 United States. The term United States means the United States, its territories, states, commonwealths, districts, and possessions, and all areas under the jurisdiction or...

  13. 31 CFR 560.307 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 560.307 Section 560.307 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 560.307 United States. The term United States means the United States, including its territories and...

  14. 7 CFR 1150.106 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 9 2010-01-01 2009-01-01 true United States. 1150.106 Section 1150.106 Agriculture... Order Definitions § 1150.106 United States. United States means the 48 contiguous States in the continental United States. ...

  15. 31 CFR 593.311 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 593.311 Section 593.311 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 593.311 United States. The term United States means the United States, its...

  16. 31 CFR 585.316 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 585.316 Section 585.316 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 585.316 United States. The term United States means the United States, its...

  17. 31 CFR 575.319 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 575.319 Section 575.319 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....319 United States. The term United States means the United States, its territories and possessions...

  18. 7 CFR 1212.31 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1212.31 Section 1212.31 Agriculture..., Consumer Education, and Industry Information Order Definitions § 1212.31 United States. “United States... territories and possessions of the United States. ...

  19. 31 CFR 539.312 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 539.312 Section 539.312 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 539.312 United States. The term United States means the United States, its...

  20. 31 CFR 551.309 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 551.309 Section 551.309 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF....309 United States. The term United States means the United States, its territories and possessions...

  1. 7 CFR 1219.26 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1219.26 Section 1219.26 Agriculture..., AND INFORMATION Hass Avocado Promotion, Research, and Information Order Definitions § 1219.26 United States. United States means collectively the several 50 States of the United States, the District of...

  2. 31 CFR 587.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 587.310 Section 587...) MILOSEVIC SANCTIONS REGULATIONS General Definitions § 587.310 United States. The term United States means the United States, its territories and possessions, and all areas under the jurisdiction or authority...

  3. 31 CFR 541.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 541.310 Section 541.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... § 541.310 United States. The term United States means the United States, its territories and possessions...

  4. 22 CFR 120.13 - United States.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false United States. 120.13 Section 120.13 Foreign... United States. United States, when used in the geographical sense, includes the several states, the Commonwealth of Puerto Rico, the insular possessions of the United States, the District of Columbia, the...

  5. 7 CFR 1205.313 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1205.313 Section 1205.313 Agriculture... Research and Promotion Order Definitions § 1205.313 United States. United States means the 50 States of the United States of America. [31 FR 16758, Dec. 31, 1966. Redesignated at 56 FR 64472, Dec. 10, 1991] ...

  6. 31 CFR 540.313 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 540.313 Section 540.313 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... REGULATIONS General Definitions § 540.313 United States. The term United States means the United States, its...

  7. 31 CFR 547.310 - United States.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false United States. 547.310 Section 547.310 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF... General Definitions § 547.310 United States. The term United States means the United States, its...

  8. Hanford Site waste management units report

    International Nuclear Information System (INIS)

    1993-04-01

    The Hanford Site Waste Management Units Report was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments of the 1984. This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in the report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of the units report, the list of units is more extensive than required by Section 3004(u) of Hazardous and Solid Waste Amendments of the 1984. In Sections 3.0 through 6.0 of this report, the four aggregate areas are subdivided into their operable units. The operable units are further divided into two parts: (1) those waste management units assigned to the operable unit that will be remediated as part of the Environmental Restoration Remedial Actions (ERRA) Program, and (2) those waste management units located within the operable unit boundaries but not assigned to the ERRA program. Only some operable unit sections contain the second part

  9. Waste management units - Savannah River Site

    International Nuclear Information System (INIS)

    1989-10-01

    This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only

  10. Organization of Control Units with Operational Addressing

    OpenAIRE

    Alexander A. Barkalov; Roman M. Babakov; Larysa A. Titarenko

    2012-01-01

    The using of operational addressing unit as the block of control unit is proposed. The new structure model of Moore finite-state machine with reduced hardware amount is developed. The generalized structure of operational addressing unit is suggested. An example of synthesis process for Moore finite-state machine with operational addressing unit is given. The analytical researches of proposed structure of control unit are executed.

  11. Masturbation in the United States.

    Science.gov (United States)

    Das, Aniruddha

    2007-01-01

    Using data from the nationally representative National Health and Social Life Survey, this study queried the correlates of masturbation in the United States in 1992. Among those aged 18-60, 38% (CI, 35-41) of women and 61% (CI, 57-65) of men reported any masturbation over the preceding year. The system of factors underlying masturbation was similar for both genders, consistent with a convergence in gender patterns of sexual expression in the United States. Among both women and men, masturbation responded to a stable sexualized personality pattern, catalyzed by early-life factors and manifested in current sexual traits. Strikingly, the masturbation-partnered sex linkage, often conceptualized either as compensating for unsatisfying sex or complementing a satisfactory sex life, appeared to be bimodal for both genders. For some, masturbation complemented an active and pleasurable sex life, while among others, it compensated for a lack of partnered sex or satisfaction in sex.

  12. Units for radiation protection work

    International Nuclear Information System (INIS)

    Lindborg, L.

    1997-06-01

    ICRU has defined special measurable (operational) quantities for radiation protection. A consequence of using the operational quantities is that hand-held and personal dosemeters can give different measuring results in the same radiation situation. The differences vary and are caused by the geometry of the radiation field. The units have well documented relations to e.g. the ICRP effective dose and equivalent dose to an organ or tissue. Therefore, it is possible to estimate these doses from a measured value of e.g. the ambient dose equivalent. ICRU and ICRP have recently reviewed these relations in two important commonly issued reports (Report 57 and Publication 74). This report tries to show the value of understanding these units and their relations and is primarily meant to be used for educational purposes. 11 refs

  13. Optical programmable Boolean logic unit.

    Science.gov (United States)

    Chattopadhyay, Tanay

    2011-11-10

    Logic units are the building blocks of many important computational operations likes arithmetic, multiplexer-demultiplexer, radix conversion, parity checker cum generator, etc. Multifunctional logic operation is very much essential in this respect. Here a programmable Boolean logic unit is proposed that can perform 16 Boolean logical operations from a single optical input according to the programming input without changing the circuit design. This circuit has two outputs. One output is complementary to the other. Hence no loss of data can occur. The circuit is basically designed by a 2×2 polarization independent optical cross bar switch. Performance of the proposed circuit has been achieved by doing numerical simulations. The binary logical states (0,1) are represented by the absence of light (null) and presence of light, respectively.

  14. Phoenix's Wet Chemistry Laboratory Units

    Science.gov (United States)

    2008-01-01

    This image shows four Wet Chemistry Laboratory units, part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) instrument on board NASA's Phoenix Mars Lander. This image was taken before Phoenix's launch on August 4, 2007. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  15. THE UNITED STATES EDUCATIONAL SYSTEM

    OpenAIRE

    David Suriñach Fernández

    2017-01-01

    The United States educational system is very complex. Due to the fact a big number of agents take play of its regulation, the differences between the education from one State compared to the education from another, or even between school districts, might be considerable. The last two largest federal education initiatives, No Child Left Behind and Race to the Top, have had a huge impact on the American education system. The escalation of the standardized test throughout the whole country as a ...

  16. The Uranium Chemistry Research Unit

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The article discusses the research work done at the Uranium Chemistry Research Unit of the University of Port Elizabeth. The initial research programme dealt with fundamental aspects of uranium chemistry. New uranium compounds were synthesized and their chemical properties were studied. Research was also done to assist the mining industry, as well as on nuclear medicine. Special mentioning is made of the use of technetium for medical diagnosis and therapy

  17. Eddy current tube testing unit

    International Nuclear Information System (INIS)

    Dufayet, J.P.; Duret, G.

    1975-01-01

    The unit described can check a wide variety of tubes in quick succession and its modular design gives it a high degree of versability. Suitably defined working conditions and specific fittings enable most of the faults encountered in the manufacture of a tube to be detected. By appropriate means of selection based on signal amplitude, phase and frequency analyses it is possible to adapt selection criteria to the seriousness of the different categories of defect [fr

  18. Environmental performance reviews: United States

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-01-15

    This book presents OECD assessments and recommendations regarding the United States' effort to manage its environment including air, water nature, and biodiversity to do this in a sustainable manner; and to do this in co-operation with its global neighbours. In particular, it assesses progress made since 1996, when OECD's previous review on the US was done. 40 figs., 21 tabs.

  19. Pricing decision-making units

    OpenAIRE

    R F&aauml;re; S Grosskopf; D Margaritis

    2013-01-01

    In this note we extend the standard DEA paradigm to address the question of how one can price DMUs (decision-making units). To do this we use an adjoint transformation to the technology generated by these DMUs which links to traditional linear programming theory of the firm and is similar to pricing portfolios in financial markets. We also provide a numerical example illustrating the practicality of the proposed method.

  20. Dixie Valley Bottoming Binary Unit

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Dale [Terra-Gen Sierra Holdings, LLC, Reno, NV (United States)

    2014-12-21

    This binary plant is the first air cooled, high-output refrigeration based waste heat recovery cycle in the industry. Its working fluid is environmentally friendly and as such, the permits that would be required with a hydrocarbon based cycle are not necessary. The unit is largely modularized, meaning that the unit’s individual skids were assembled in another location and were shipped via truck to the plant site. The Air Cooled Condensers (ACC), equipment piping, and Balance of Plant (BOP) piping were constructed at site. This project further demonstrates the technical feasibility of using low temperature brine for geothermal power utilization. The development of the unit led to the realization of low temperature, high output, and environmentally friendly heat recovery systems through domestic research and engineering. The project generates additional renewable energy, resulting in cleaner air and reduced carbon dioxide emissions. Royalty and tax payments to governmental agencies will increase, resulting in reduced financial pressure on local entities. The major components of the unit were sourced from American companies, resulting in increased economic activity throughout the country.

  1. United States National Seismographic Network

    International Nuclear Information System (INIS)

    Buland, R.

    1993-09-01

    The concept of a United States National Seismograph Network (USNSN) dates back nearly 30 years. The idea was revived several times over the decades. but never funded. For, example, a national network was proposed and discussed at great length in the so called Bolt Report (U. S. Earthquake Observatories: Recommendations for a New National Network, National Academy Press, Washington, D.C., 1980, 122 pp). From the beginning, a national network was viewed as augmenting and complementing the relatively dense, predominantly short-period vertical coverage of selected areas provided by the Regional Seismograph Networks (RSN's) with a sparse, well-distributed network of three-component, observatory quality, permanent stations. The opportunity finally to begin developing a national network arose in 1986 with discussions between the US Geological Survey (USGS) and the Nuclear Regulatory Commission (NRC). Under the agreement signed in 1987, the NRC has provided $5 M in new funding for capital equipment (over the period 1987-1992) and the USGS has provided personnel and facilities to develop. deploy, and operate the network. Because the NRC funding was earmarked for the eastern United States, new USNSN station deployments are mostly east of 105 degree W longitude while the network in the western United States is mostly made up of cooperating stations (stations meeting USNSN design goals, but deployed and operated by other institutions which provide a logical extension to the USNSN)

  2. Pickering Unit 1 chemical cleaning

    International Nuclear Information System (INIS)

    Smee, J.L.; Fiola, R.J.; Brennenstuhl, K.R.; Zerkee, D.D.; Daniel, C.M.

    1995-01-01

    The secondary sides of all 12 boilers at Pickering Unit 1 were chemically cleaned in 1994 by the team of Ontario Hydro, B and W International (Cambridge, Ontario) and B and W Nuclear Technologies (Lynchburg, Virginia). A multi-step EPRI/SGOG process was employed in a similar manner to previous clearings at Units 5 and 6 in 1992 and 1993, respectively. A major innovation with the Unit 1 cleaning was the incorporation of a crevice cleaning step, the first time this had been done on Ontario Hydro plants. In addition, six boilers were cleaned in parallel compared to three at a time in previous Pickering cleanings. This significantly reduced cleaning time. A total of 6,770 kg of sludge was removed through direct chemical dissolution. It consisted of 66% iron/nickel oxides and 28% copper metal. A total of 1,600,000 L (420,000 US gallons) of liquid waste was produced. It was processed through the spent solvent treatment facility located at the Bruce Nuclear Power Development site. Visual inspection performed after the cleaning indicated that the crevices between the boiler tubes and the tube support structure were completely clear of deposit and the general condition of the tubing and lattice bars appeared to be in 'as new' condition. (author)

  3. Measurement units of physical values

    International Nuclear Information System (INIS)

    Debraine, P.

    1955-01-01

    The aim of this paper is twofold: 1) to give an analysis of the formation conditions of the various systems of units, 2) to show how the practical problems involving changes of units can be solved. This analysis leads to the conception of 'types' of systems, which is very useful to clarity the question of rationalized and non rationalized systems. The second point which consists essentially in: 1) finding the relationship between the measures of a given quantity in different systems, 2) deriving practical formulas, 3) deriving formulas in various 'types' of systems, is made easier by use of sets of: * definition formulas, * transformation formulas, * units of the various practical systems with useful numerical information covering the following fields: ** geometry, ** kinematics, ** mechanics, ** electricity and magnetism, ** thermodynamics, ** radiation, ** photometry, These sets being printed on coloured paper can be easily found. A number of numerical examples (21) show in a detailed way how to solve the various problems likely to occur. A chapter is particularly devoted to the Giorgi MKS system. (author) [fr

  4. Low cost balancing unit design

    Science.gov (United States)

    Golembiovsky, Matej; Dedek, Jan; Slanina, Zdenek

    2017-06-01

    This article deals with the design of a low-cost balancing system which consist of battery balancing units, accumulator pack units and coordinator unit with interface for higher level of battery management system. This solution allows decentralized mode of operation and the aim of this work is implementation of controlling and diagnostic mechanism into an electric scooter project realized at Technical university of Ostrava. In todays world which now fully enjoys the prime of electromobility, off-grid battery systems and other, it is important to seek the optimal balance between functionality and the economy side of BMS that being electronics which deals with secondary cells of batery packs. There were numerous sophisticated, but not too practical BMS models in the past, such as centralized system or standalone balance modules of individual cells. This article aims at development of standalone balance modules which are able to communicate with the coordinator, adjust their parameters and ensure their cells safety in case of a communication failure. With the current worldwide cutting cost trend in mind, the emphasis was put on the lowest price possible for individual component. The article is divided into two major categories, the first one being desing of power electronics with emphasis on quality, safety (cooling) and also cost. The second part describes development of a communication interface with reliability and cost in mind. The article contains numerous graphs from practical measurements. The outcome of the work and its possible future is defined in the conclusion.

  5. Strategic renewal for business units.

    Science.gov (United States)

    Whitney, J O

    1996-01-01

    Over the past decade, business units have increasingly taken the role of strategy formulation away from corporate headquarters. The change makes sense: business units are closer to customers, competitors, and costs. Nevertheless, business units can fail, just as headquarters once did, by losing their focus on the organization's priorities and capabilities. John Whitney--turnaround expert and professor of management at Columbia University--offers a method for refocusing companies that he calls the strategic-renewal process. The principles behind the process are straightforward, but its execution demands extensive data, rigorous analysis, and the judgment of key decision makers. However, when applied with diligence, it can produce a strategy that yields both growth and profit. To carry out the process, managers must analyze, one by one or in logical groupings, the company's customers, the products it sells, and the services it offers in light of three criteria: strategic importance, significance, and profitability. Does a given customer, product, or service mesh with the organization's goals? Is it significant in terms of current and future revenues? And is it truly profitable when all costs are care fully considered? Customers, products, and services that do not measure up, says the author, must be weeded out relentlessly. Although the process is a painstaking one, the article offers clear thinking on why-and how-to go about it. A series of exhibits takes managers through the questions they need to raise, and two matrices offer Whitney's concentrated wisdom on when to cultivate--and when to prune.

  6. High pressure gas reinjection unit

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    Nuovo Pignone has built for gas reinjection at Ekofisk the highest pressure injection unit to date: suction pressure 246 bar, discharge 647 bar, for 5.7 million cu m/day of natural gas, and driven by a GE MS 5001 gas turbine of 24,000 hp. The barrel-type compressor has been used already in Algeria at Hassi Messaoud. Full scale tests have shown that the unit is satisfactory; special attention being paid to the stability of the rotor. Air cooled heat exchangers were used in the test loop to cool the discharge gas; at Ekofisk, heat exchangers with sea water will be used. The valves in the test loop were of a special, low- noise type. Vibrations of the rotor system and changes in gas pressure monitored, showing that a pressure of 680 bars can be achieved without instability. Economic considerations lead to preference for rotary compressors driven by gas turbines for similar applications in the exploitation of oil fields. A graph of the characteristics of the unit is given.

  7. Coin sorting unit; Koka ikkatsu tonyu shori unit

    Energy Technology Data Exchange (ETDEWEB)

    Oyabu, H.; Nishiyama, T.; Iijima, S. [Fuji Electric Co. Ltd., Tokyo (Japan)

    1999-08-10

    There are promising demands for barrier-free vending machines which can easily be used by the aged and the handicapped as well as ordinary people. Fuji Electric had developed an advanced unit for throwing in coins for the new hearty series that can smoothly be used by the aged and the handicapped. Its main advantages are (1) two or more coins can be thrown in together, (2) The port for putting in coins and the port for taking out change are of unified construction and simply adjoin each other, (3) Directional signs in braille are added. (author)

  8. Hanford Site waste management units report

    International Nuclear Information System (INIS)

    1993-04-01

    The Hanford Site Waste Management Units Report was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments of the 1984. This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in the report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of the units report, the list of units is more extensive than required by Section 3004(u) of Hazardous and Solid Waste Amendments of the 1984. In Sections 3.0 through 6.0 of this report, the four aggregate areas are subdivided into their operable units. The operable units are further divided into two parts: (1) those waste management units assigned to the operable unit that will be remediated as part of the Environmental Restoration Remedial Actions (ERRA) Program, and (2) those waste management units located within the operable unit boundaries but not assigned to the ERRA program. Only some operable unit sections contain the second part.Volume two contains Sections 4.0 through 6.0 and the following appendices: Appendix A -- acronyms and definition of terms; Appendix B -- unplanned releases that are not considered to be units; and Appendix C -- operable unit maps

  9. Uniting to prevent unwanted pregnancies.

    Science.gov (United States)

    Lynch, D

    1994-02-18

    In reading the column of Cal Thomas entitled "Speaking Truth to Power" it becomes clear that the forces aligned against each other on the issue of reproductive choice should work together in order to reduce the number of unwanted pregnancies. An estimated 400 million women are unable to limit their family size for economic reasons. More are inhibited by social or religious constraints. When family planning (FP) services are available, and the status and education levels of women are raised, abortion rates decrease. This is demonstrated in the Netherlands, where legal abortions and contraception are available. The abortion rate is less than 5/1000 women there, one of the lowest worldwide. Latin America, where abortion is illegal and FP services are lacking, has abortion rates of 30-60/1000. Furthermore, these illegal abortions usually have a tragic effect on the woman's health. Of an estimated 6 million pregnancies annually in the United States, approximately half are unintended. Of these, about 1.6 million are aborted. Of the women in the United States who become pregnant annually, 82% are unmarried, 25% are under 20 years of age, and 33% make less than $11,000 yearly. If industrialized nations made contraceptives and FP services available to the poor worldwide, the quality of life on earth would increase. Human misery, anarchy, and resource depletion would decrease. State and local governments should increase support of domestic FP activities, while the federal government should raise its funding of international FP services. In order to reach the goals set by the 1989 Amsterdam Declaration, which was signed by the US, the annual contribution of the United States needs to be doubled. 4% of the US foreign aid budget, $720 million, is less than 0.1% of its $1.5 trillion budget. This amounts to less than $3 per US citizen.

  10. Entomology Unit annual report 2003

    International Nuclear Information System (INIS)

    2003-01-01

    As described in the 2002 Annual Report an improved medfly genetic sexing strain (GSS) was developed, VIENNA 8. This strain shows improved production characteristics and will have a major impact on the production efficiency in SIT rearing facilities. During 2003 this strain was transferred to four rearing facilities in Guatemala, Peru, South Africa and Tunisia based on acceptable QC data developed for the strain in the Unit. For the first time the strain was transferred to the different facilities under an agreement that prevents further distribution to third parties without consent of the Unit. In the past, strains originating from the Unit have been freely exchanged within the medfly SIT community, sometimes with not always the best results. During 2003 there has been a substantial increase in the resources devoted to activities in fruit flies other than medfly e.g. Bactrocera oleae and Anastrepha fraterculus. Rearing of the olive fly, B. oleae has traditionally not been straightforward due to the very specific, and expensive, larval diet that is required by this monophagous pest. With the disappearance of an essential larval diet component from the commercial market an urgent search is underway for an alternative. In 2004, experiments will be carried out to identify improved larval diets. For A. fraterculus, a large-scale evaluation of mating compatibility between different geographical races has been carried out by a consultant. Progress has been made in the containerised rearing of tsetse fly colonies. The container required considerable work before the temperature and humidity controls were suitable for tsetse rearing and a closed colony of Glossina fuscipes is now being reared. Discussions are now underway to install a version of TPU 3.2 (an automated tsetse feeding and production unit) in the container. A protocol for the handling, irradiation and eventual release of large numbers of sterile male tsetse has been formulated and it will involve at least two

  11. Optics in the United kingdom.

    Science.gov (United States)

    Ditchburn, R W

    1969-10-01

    Optics is interpreted to include x-ray optics, electronic optics, and short wave radiooptics as well as the more conventional visible, uv, and ir optics. Recent work in Britain on x-ray optics (applied to molecular biology), on scanning electron microscopy, and in radioastronomy (discovery of pulsars) is mentioned. In the optics of the visible and ir there is an increasing interest in over-all systems design. .The formation of large industrial units capable of carrying through major design program, requiring advanced mechanical and electronic design associated with new lens systems, is welcomed.

  12. Graphs with Eulerian unit spheres

    OpenAIRE

    Knill, Oliver

    2015-01-01

    d-spheres in graph theory are inductively defined as graphs for which all unit spheres S(x) are (d-1)-spheres and that the removal of one vertex renders the graph contractible. Eulerian d-spheres are geometric d-spheres which are d+1 colorable. We prove here that G is an Eulerian sphere if and only if the degrees of all the (d-2)-dimensional sub-simplices in G are even. This generalizes a Kempe-Heawood result for d=2 and is work related to the conjecture that all d-spheres have chromatic numb...

  13. Enhanced Master Controller Unit Tester

    Science.gov (United States)

    Benson, Patricia; Johnson, Yvette; Johnson, Brian; Williams, Philip; Burton, Geoffrey; McCoy, Anthony

    2007-01-01

    The Enhanced Master Controller Unit Tester (EMUT) software is a tool for development and testing of software for a master controller (MC) flight computer. The primary function of the EMUT software is to simulate interfaces between the MC computer and external analog and digital circuitry (including other computers) in a rack of equipment to be used in scientific experiments. The simulations span the range of nominal, off-nominal, and erroneous operational conditions, enabling the testing of MC software before all the equipment becomes available.

  14. Loviisa Unit One: Annealing - healing

    Energy Technology Data Exchange (ETDEWEB)

    Kohopaeae, J.; Virsu, R. [ed.; Henriksson, A. [ed.

    1997-11-01

    Unit 1 of the Loviisa nuclear powerplant was annealed in connection with the refuelling outage in the summer of 1996. This type of heat treatment restored the toughness properties of the pressure vessel weld, which had been embrittled be neutron radiation, so that it is almost equivalent to a new weld. The treatment itself was an ordinary metallurgical procedure that took only a few days. But the material studies that preceded it began over fifteen years ago and have put IVO at the forefront of world-wide expertise in the area of radiation embrittlement

  15. Multi-Unit Initiating Event Analysis for a Single-Unit Internal Events Level 1 PSA

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong San; Park, Jin Hee; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The Fukushima nuclear accident in 2011 highlighted the importance of considering the risks from multi-unit accidents at a site. The ASME/ANS probabilistic risk assessment (PRA) standard also includes some requirements related to multi-unit aspects, one of which (IE-B5) is as follows: 'For multi-unit sites with shared systems, DO NOT SUBSUME multi-unit initiating events if they impact mitigation capability [1].' However, the existing single-unit PSA models do not explicitly consider multi-unit initiating events and hence systems shared by multiple units (e.g., alternate AC diesel generator) are fully credited for the single unit and ignores the need for the shared systems by other units at the same site [2]. This paper describes the results of the multi-unit initiating event (IE) analysis performed as a part of the at-power internal events Level 1 probabilistic safety assessment (PSA) for an OPR1000 single unit ('reference unit'). In this study, a multi-unit initiating event analysis for a single-unit PSA was performed, and using the results, dual-unit LOOP initiating event was added to the existing PSA model for the reference unit (OPR1000 type). Event trees were developed for dual-unit LOOP and dual-unit SBO which can be transferred from dual- unit LOOP. Moreover, CCF basic events for 5 diesel generators were modelled. In case of simultaneous SBO occurrences in both units, this study compared two different assumptions on the availability of the AAC D/G. As a result, when dual-unit LOOP initiating event was added to the existing single-unit PSA model, the total CDF increased by 1∼ 2% depending on the probability that the AAC D/G is available to a specific unit in case of simultaneous SBO in both units.

  16. Chapter 2. The production units

    International Nuclear Information System (INIS)

    1998-01-01

    In the second chapter of this CD ROM the production units of the Slovak Electric, Plc. (Slovenske elektrarne, a.s.), are presented. It consist of next paragraphs: (1) Nuclear power plants (A-1 Nuclear Power Plant (History, Technological scheme, basic data are presented); V-1, V-2 Bohunice Nuclear Power Plant (History 1972-1985, technological scheme; nuclear safety, radiation protection, heat supply, international co-operation and basic data are presented); Mochovce Nuclear Power Plant (History 1980-1998, technological scheme, construction completion, milestones of commissioning, safety and environmental protection as well as basic data are included). (2) Conventional sources of energy (Vojany fossil power plant (History 1959-1992, Technological units of power plant, Impact of operation on the environment, Plant of Vojany FPP Renewal and Reconstruction, Basic data are listed), Novaky fossil power plant (History 1949-1998, Technological scheme, current investment construction, basic data, Handlova heating plant). Kosice Combined Heat Power Plant (History 1960-1995, technological scheme, State metrology centre, acredited chemical laboratory, basic data). (3) Hydroelectric power plants (Trencin HPPs: Cierny Vah pumped storage HPP, Liptovska Mara HPP, Orava HPP, Sucany HPP, Miksova HPP, Nosice HPP, Velke Kozmalovce HPP, Gabcikovo HPP, Dubnica HPP, Nove Mesto n/V HPP, Madunice HPP, Kralova HPP) and Dobsina HPPs: (Dobsina HPP, Ruzin HPP, Domasa HPP, small HPPs) are presented

  17. Are environmental scanning units effective?

    Science.gov (United States)

    Stubbart, C

    1982-06-01

    Many authorities have urged companies to set up environmental scanning to assist corporate planning. Some advocates have recommended a unit at corporate level. This would give breadth of view and penetration into the future. It would arm decision makers with accurate forecasts. The information would be broad in scope and future directed. It could provide also assumptions for long-range planning. The Fahey and King study produced a model of corporate scanning types. The data showed that environmental information was built into the plan. Though the political environment was important, scanning was inadequate. The best location for scanning was not at corporate level and most firms used irregular methods. The Thomas study concluded that effective environmental scanning was permanent and multi level and that 'best practice' was continuous scanning. In 1978 the sample organizations were revisited. Five of the twelve have not changed their practice. The factors which encouraged a continuous model were the attitudes of academics and business media, demonstrated success of the units, the right kind of personnel. Contrary influences were changes in top management, decentralization moves, resource cuts, defining the environment and its significance, the availability of scanning competent personnel, surprise itself, and the availability of alternatives e.g. external forecasts.

  18. East Carnduff Unit: corrosion problems

    Energy Technology Data Exchange (ETDEWEB)

    Banks, C D

    1966-07-01

    Waterflooding of the East Carnduff Unit began in late 1962. The first injection line leak was discovered April 29, 1965. The first 6 leaks in the East Carnduff Unit occurred within a period of less than one month--a very startling and serious warning of pending problems. Analysis of the pipe removed showed a deep pit covered by a severe scale in the piping fitting. Several remedial actions were tried in order to develop the present inhibition program. First, the lines were cleaned as well as possible utilizing rubber pig spheres with normal injection pressure. This proved very effective and 2 passes wiped out most of the scale in the lines. Only one line required acid. After the lines had been cleaned, a water treating rate of an organic amine corrosion inhibitor, 10 ppm of the scale inhibitor, and bactericide at the rate of 40 ppm slugs 2 days per month was initiated. The above treating program is in use at the present time and is maintaining a very low leak frequency. This experience has demonstrated 2 important points in waterflood operations: (1) a bare piping system in warm brine service requires constant attention to insure that it is being kept clean; and (2) reliance cannot be placed on any one method of checking corrosion rates.

  19. Devolution in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Marković Ratko

    2014-01-01

    Full Text Available Devolution is a transfer of the legislative powers of the Westminster Parliament to the parliaments of the historical provinces once united with England into the United Kingdom, which are directly elected by the provincial population. That delegation is asymmetrical and revocable, but it does not affect the basic norms of the British unwritten constitution on parliamentary supremacy. Over the devolution the provinces do not acquire the primary competence, but the one that is given to them by the transfer of the legislative powers of the Westminster Parliament. A special law retaining the Westminster Parliament's primary competence and sovereignty grants this competence. Regarding the scope of the devolved powers of the provinces and the organizational mechanism for their execution, there is a significant asymmetry. In all the provinces, there is a unique junction between devolved powers and their holders. Before the referendum on the independence in Scotland in September 2014, the increase of devolved powers was promised not only for all the historical provinces (Scotland, Wales, Northern Ireland, but for England as well, which represents a step towards the federalization of the UK. Devolution and several other institutions of the British constitution also, have a stamp 'Made in Britain' which does not allow easy imitation and transfer to another countries and their constitutions.

  20. Equivalent unit in telecommunications services

    Directory of Open Access Journals (Sweden)

    Luiza Santangelo Reis

    2016-03-01

    Full Text Available The aim of this study is to analyze the relationship between the “cost” and “production” variables in a telecommunications company, measuring the latter in the unit of measure termed Network Units (NU.  The study shows a Pearson correlation coefficient of 0.55 -evaluated as moderate - over the course of a 24-month period and resulting from 177 trials.  Subsequently, only the work teams composed of the company´s standard structure were taken into consideration, which yielded 32 observations of interest and a derived correlation coefficient of 0.8.  Finally, the data pertaining to each individual work team over a determined length of time was analyzed, showing strong correlation coefficients in seven of the eleven, and in the remainder, a moderate linear relationship between the variables analyzed.  These results suggest the viability of applying the NU production measurement model in the telecommunications company in question

  1. Teen Pregnancy in the United States

    Science.gov (United States)

    ... United States: the contribution of abstinence and improved contraceptive use. Am J Public Health. 2007;97(1):150-6. Lindberg LD, Santelli JS, Desai, S. Understanding the Decline in Adolescent Fertility in the United States, 2007–2012. J ...

  2. 76 FR 66845 - United Nations Day, 2011

    Science.gov (United States)

    2011-10-27

    ... become ever more intertwined, the leadership, staff, and member states of the United Nations continue to... a time of dramatic political transformation, the United Nations can embrace democratic movements and...

  3. 16-channel analog store and multiplexer unit

    Energy Technology Data Exchange (ETDEWEB)

    Brossard, M; Kulka, Z [Clermont-Ferrand-2 Univ., 63 - Aubiere (France). Lab. de Physique Corpusculaire

    1979-03-15

    A 16-channel analog store and multiplexer unit is described. The unit enables storing and selection of analog information which is then digitally encoded by single ADC. This solution becomes economically attractive particularly in multidetector pulse height analysis systems.

  4. Coordinator, Evaluation Unit | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Job Summary The Evaluation Unit Coordinator is expected to: ... with Centre policies and procedures and disseminates information to Unit staff on changes ... Coordinates the planning and organization of technical and administrative meetings ...

  5. Order units in a C-algebra

    Indian Academy of Sciences (India)

    Abstract. Order unit property of a positive element in a *-algebra is defined. It is proved that precisely projections satisfy this order theoretic property. This way, unital hereditary *-subalgebras of a *-algebra are characterized.

  6. Labour of love yields new maternity unit.

    Science.gov (United States)

    2012-01-01

    Birmingham's City Hospital's new maternity unit is an inspiring departure from conventional units. Contemporary design and the latest technology combine to give mothers a safe, yet relaxed, environment in which to give birth. HEJ reports.

  7. Fatigue in Breakwater Concrete Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units.......The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units....

  8. Vehicle with inclinable caterpillar propulsion units

    International Nuclear Information System (INIS)

    Clar, G.

    1991-01-01

    This vehicle usable in hostile environment such nuclear industry has four propulsion units with a caterpillar track and two integrated motors: one for advancing the caterpillar track and the other for inclining the propulsion unit when overcoming obstacles. Each propulsion unit is easily replaceable because there are no mechanical parts in the body of the vehicle [fr

  9. 24 CFR 970.31 - Replacement units.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Replacement units. 970.31 Section... PUBLIC HOUSING PROGRAM-DEMOLITION OR DISPOSITION OF PUBLIC HOUSING PROJECTS § 970.31 Replacement units. Notwithstanding any other provision of law, replacement public housing units may be built on the original public...

  10. Oil Vulnerabilities and United States Strategy

    Science.gov (United States)

    2007-02-08

    Mazda, Mercedes - Benz , Ford, Mercury, and Nissan offer flexible fuel vehicles in the United States. Ethanol is currently produced in the United States...USAWC STRATEGY RESEARCH PROJECT OIL VULNERABILITIES AND UNITED STATES STRATEGY by Colonel Shawn P. Walsh...Colleges and Schools, 3624 Market Street, Philadelphia, PA 19104, (215) 662-5606. The Commission on Higher Education is an institutional accrediting

  11. 7 CFR 1215.20 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1215.20 Section 1215.20 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... United States. United States means all of the States. Popcorn Board ...

  12. 7 CFR 1260.108 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1260.108 Section 1260.108 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING AGREEMENTS... Promotion and Research Order Definitions § 1260.108 United States. United States means the 50 States and the...

  13. 7 CFR 1280.127 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1280.127 Section 1280.127 Agriculture... INFORMATION ORDER Lamb Promotion, Research, and Information Order Definitions § 1280.127 United States. United States means collectively the 50 States and the District of Columbia. ...

  14. 7 CFR 1210.315 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1210.315 Section 1210.315 Agriculture... PLAN Watermelon Research and Promotion Plan Definitions § 1210.315 United States. United States means each of the several States and the District of Columbia. [60 FR 10797, Feb. 28, 1995] National...

  15. 7 CFR 1221.32 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1221.32 Section 1221.32 Agriculture... INFORMATION ORDER Sorghum Promotion, Research, and Information Order Definitions § 1221.32 United States. United States or U.S. means collectively the 50 States, the District of Columbia, the Commonwealth of...

  16. 7 CFR 1216.30 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1216.30 Section 1216.30 Agriculture... INFORMATION ORDER Peanut Promotion, Research, and Information Order Definitions § 1216.30 United States. United States means collectively the 50 states, the District of Columbia, the Commonwealth of Puerto Rico...

  17. 7 CFR 1218.22 - United States.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false United States. 1218.22 Section 1218.22 Agriculture... INFORMATION ORDER Blueberry Promotion, Research, and Information Order Definitions § 1218.22 United States. United States means collectively the 50 states, the District of Columbia, the Commonwealth of Puerto Rico...

  18. SPOKEN CUZCO QUECHUA, UNITS 1-6.

    Science.gov (United States)

    SOLA, DONALD F.; AND OTHERS

    THE MATERIALS IN THIS VOLUME COMPRISE SIX UNITS WHICH PRESENT BASIC ASPECTS OF CUZCO QUECHUA PHONOLOGY, MORPHOLOGY, AND SYNTAX FOR THE BEGINNING STUDENT. THE SIX UNITS ARE DESIGNED FOR APPROXIMATELY 120 HOURS OF SUPERVISED CLASS WORK WITH OUTSIDE PREPARATION EXPECTED OF THE STUDENT. EACH UNIT CONSISTS OF A DIALOGUE TO BE MEMORIZED, A DIALOGUE…

  19. United Nations and multilateralism: appraising USA's unilateralism ...

    African Journals Online (AJOL)

    Multilateralism as symbolized by the United Nations Organization, seems to have come under threat today, and nowhere is this more evident than in the United States-United Nations relations particularly in the area of military interventions around the world. The aim of this paper is to appraise the practice of the principle of ...

  20. Ecological units of the Northern Region: Subsections

    Science.gov (United States)

    John A. Nesser; Gary L. Ford; C. Lee Maynard; Debbie Dumroese

    1997-01-01

    Ecological units are described at the subsection level of the Forest Service National Hierarchical Framework of Ecological Units. A total of 91 subsections are delineated on the 1996 map "Ecological Units of the Northern Region: Subsections," based on physical and biological criteria. This document consists of descriptions of the climate, geomorphology,...

  1. Image processing unit with fall-back.

    NARCIS (Netherlands)

    2011-01-01

    An image processing unit ( 100,200,300 ) for computing a sequence of output images on basis of a sequence of input images, comprises: a motion estimation unit ( 102 ) for computing a motion vector field on basis of the input images; a quality measurement unit ( 104 ) for computing a value of a

  2. Unit area control in California forests

    Science.gov (United States)

    William E. Hallin

    1951-01-01

    There is a definite distinction between the basic concept of unit area control and the specific techniques or treatments used for specific units. Unit area control as a term was first used in connection with a cutting trial in the sugar pine-fir type; consequently, many foresters think the term refers merely to the technique used in sugar pine management, This is not...

  3. 12 CFR 541.10 - Dwelling unit.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Dwelling unit. 541.10 Section 541.10 Banks and... FEDERAL SAVINGS ASSOCIATIONS § 541.10 Dwelling unit. The term dwelling unit means the unified combination of rooms designed for residential use by one family, other than a single-family dwelling. ...

  4. Malaria Surveillance - United States, 2015.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M; Tan, Kathrine R

    2018-05-04

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles species mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to provide information on its occurrence (e.g., temporal, geographic, and demographic), guide prevention and treatment recommendations for travelers and patients, and facilitate transmission control measures if locally acquired cases are identified. This report summarizes confirmed malaria cases in persons with onset of illness in 2015 and summarizes trends in previous years. Malaria cases diagnosed by blood film microscopy, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff members. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System (NMSS), the National Notifiable Diseases Surveillance System (NNDSS), or direct CDC consultations. CDC reference laboratories provide diagnostic assistance and conduct antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. This report summarizes data from the integration of all NMSS and NNDSS cases, CDC reference laboratory reports, and CDC clinical consultations. CDC received reports of 1,517 confirmed malaria cases, including one congenital case, with an onset of symptoms in 2015 among persons who received their diagnoses in the United States. Although the number of

  5. Sleep in intensive care unit

    DEFF Research Database (Denmark)

    Boyko, Yuliya; Jennum, Poul; Nikolic, Miki

    2017-01-01

    PURPOSE: To determine if improving intensive care unit (ICU) environment would enhance sleep quality, assessed by polysomnography (PSG), in critically ill mechanically ventilated patients. MATERIALS AND METHODS: Randomized controlled trial, crossover design. The night intervention "quiet routine...... Medicine) sleep scoring criteria were insufficient for the assessment of polysomnograms. Modified classification for sleep scoring in critically ill patients, suggested by Watson et al. (Crit Care Med 2013;41:1958-1967), was used. RESULTS: Sound level analysis showed insignificant effect...... patients. We were not able to further reduce the already existing low noise levels in the ICU and did not find any association between the environmental intervention and the presence of normal sleep characteristics in the PSG....

  6. Fracking in the United States

    International Nuclear Information System (INIS)

    Cho, Renee

    2015-01-01

    Over the last decade, advances in technology have made it profitable to extract natural gas from shale, leading to a boom in shale gas development in the United States. Hydraulic fracturing, or fracking, the controversial method for extracting natural gas, offers numerous benefits: relatively cheap energy, enhanced energy security, job creation, tax revenues and decreased dependence on dirty coal. Fracking, however, can also increase greenhouse gas emissions, pollute the air and result in health effects, consume huge quantities of water, and cause earthquakes. While some areas welcome fracking for the economic benefits it brings, other communities are attempting to ban fracking altogether. This article examines the benefits and risks of fracking in the U.S

  7. United States uranium enrichment policies

    International Nuclear Information System (INIS)

    Roberts, R.W.

    1977-01-01

    ERDA's uranium enrichment program policies governing the manner in which ERDA's enrichment complex is being operated and expanded to meet customer requirements for separative work, research and development activities directed at providing technology alternatives for future enrichment capacity, and establishing the framework for additional domestic uranium enrichment capacity to meet the domestic and foreign nuclear industry's growing demand for enrichment services are considered. The ERDA enrichment complex consists of three gaseous diffusion plants located in Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Today, these plants provide uranium enrichment services for commercial nuclear power generation. These enrichment services are provided under contracts between the Government and the utility customers. ERDA's program involves a major pilot plant cascade, and pursues an advanced isotope separation technique for the late 1980's. That the United States must develop additional domestic uranium enrichment capacity is discussed

  8. Biblis unit A thirty years

    International Nuclear Information System (INIS)

    Lauer, H.

    2004-01-01

    The first nuclear power plant in the Federal Republic of Germany started operation in 1961. It was followed by a consistent period of development until a new energy source had become available by the late sixties which was both powerful and capable of expansion. With 1200 MW electric power, the pressurized water reactor of Biblis A in 1974 was equipped with the world's most powerful single-shaft turbine generator. In 187,656 hours of operation, Biblis A over the past thirty years generated slightly more than 211 billion kWh of gross electricity (by July 31, 2004). The operating experience accumulated also resulted in improvements and modifications of technical plant systems in the 1970s and 1980s which served to bring the unit up to the then current state of the art. Modifications of technical plant systems serving to increase the safety margins or improve operating systems, always in the light of the state of the art, have been carried out consistently and continuously over the years. In combination with a high level of qualification of the operating personnel, which is ensured by an efficient system of primary and refresher training courses of responsible shift personnel and other groups of power plant personnel, this creates a lasting foundation of safe plant operation. In connection with the preparations for, and the execution of, revision outages, Biblis provided the first experience with a PWR of this size category. Unit A of the Biblis nuclear power station is proof of the fact that technical and safety challenges can be solved, and have been solved, by engineering expertise. The high availability and low susceptibility to failure of the plant demonstrate the widely optimized maintenance strategy and the high qualification and motivation of the staff. (orig.)

  9. Edexcel A2 Physics Student Unit Guide

    CERN Document Server

    Benn, Mike

    2010-01-01

    Student Unit Guides are perfect for revision. Each guide is written by an examiner and explains the unit requirements, summarises the relevant unit content and includes a series of specimen questions and answers. There are three sections to each guide:. Introduction - includes advice on how to use the guide, an explanation of the skills being tested by the assessment objectives, an outline of the unit or module and, depending on the unit, suggestions for how to revise effectively and prepare for the examination questions. Content Guidance - provides an examiner's overview of the module's key t

  10. AQA A2 Chemistry Student Unit Guide

    CERN Document Server

    Cross, Margaret

    2010-01-01

    Student Unit Guides are perfect for revision. Each guide is written by an examiner and explains the unit requirements, summarises the relevant unit content and includes a series of specimen questions and answers. There are three sections to each guide:. Introduction - includes advice on how to use the guide, an explanation of the skills being tested by the assessment objectives, an outline of the unit or module and, depending on the unit, suggestions for how to revise effectively and prepare for the examination questions. Content Guidance - provides an examiner's overview of the module's key t

  11. Development of reliability database for safety-related I and C component based on operating experience of KSNP

    International Nuclear Information System (INIS)

    Jang, S. C.; Han, S. H.; Min, K. R.

    2001-01-01

    Reliability database for safety-related I and C components has been developed, based on domestic operating experience of total 8.63 years from four units-Yonggwang Units 3 and 4, and Ulchin Units 3 and 4. This plant-specific data of safety-related I and C components has compared with operating experience for CE-supplied plants in U.S.A. As a results, we found that on the whole the domestic reliability data was similar to CE-supplied plants in USA, through lots of failures occurred early in the commercial operation were included in our analyses without percolation

  12. Hanford Site Waste Managements Units reports

    International Nuclear Information System (INIS)

    1992-01-01

    The Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC 1984). This report provides a comprehensive inventory of all types of waste management units at the Hanford Site, including a description of the units and the waste they contain. Waste management units in this report include: (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment, storage, and disposal (TSD) units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. The information in this report is extracted from the Waste Information Data System (WIDS). The WIDS provides additional information concerning the waste management units contained in this report and is maintained current with changes to these units. This report is updated annually if determined necessary per the Hanford Federal Facility Agreement and Consent Order Order (commonly referred to as the Tri-Party Agreement, Ecology et al. 1990). This report identifies 1,414 waste management units. Of these, 1,015 units are identified as solid waste management units (SWMU), and 342 are RCRA treatment, storage, and disposal units. The remaining 399 are comprised mainly of one-time spills to the environment, sanitary waste disposal facilities (i.e., septic tanks), and surplus facilities awaiting decontamination and decommissioning

  13. 3 CFR - Waiver of Reimbursement Under the United Nations Participation Act to Support the United Nations...

    Science.gov (United States)

    2010-01-01

    ... Participation Act to Support the United Nations/African Union Mission in Darfur Presidential Documents Other... the United Nations Participation Act to Support the United Nations/African Union Mission in Darfur... the United Nations/African Union Mission in Darfur to support the airlift of equipment for...

  14. Discharge from an emergency department observation unit and a surgical assessment unit

    DEFF Research Database (Denmark)

    Schultz, Helen; Qvist, Niels; Backer Mogensen, Christian

    2014-01-01

    To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit.......To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit....

  15. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to identify episodes of local transmission and to guide prevention recommendations for travelers. This report summarizes cases in persons with onset of illness in 2014 and trends during previous years. Malaria cases diagnosed by blood film, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System, National Notifiable Diseases Surveillance System, or direct CDC consultations. CDC conducts antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. Data from these reporting systems serve as the basis for this report. CDC received reports of 1,724 confirmed malaria cases, including one congenital case and two cryptic cases, with onset of symptoms in 2014 among persons in the United States. The number of confirmed cases in 2014 is consistent with the number of confirmed cases reported in 2013 (n = 1,741; this number has been updated from a previous publication to account for delayed reporting for persons with symptom onset occurring in late 2013). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 66.1%, 13.3%, 5.2%, and 2.7% of cases, respectively

  16. Hanford Site Waste Management Units Report

    International Nuclear Information System (INIS)

    1991-01-01

    This Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC). The report provides a comprehensive inventory of all types of waste management units at the Hanford Site and consists of waste disposal units, including (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structure, (5) RCRA treatment and storage units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. In support of the Hanford RCRA permit, a field was added to designate whether the waste management unit is a solid waste management unit (SWMU). As SWMUs are identified, they will added to the Hanford Waste Information Data System (WIDS), which is the database supporting this report, and added to the report at its next annual update. A quality review of the WIDS was conducted this past year. The review included checking all data against their reference and making appropriate changes, updating the data elements using the most recent references, marking duplicate units for deletion, and addition additional information. 6 refs

  17. Hanford Site Waste Management Units Report

    International Nuclear Information System (INIS)

    1991-01-01

    This Hanford Site Waste Management Units Report (HSWMUR) was originated to provide information responsive to Section 3004(u) of the Hazardous and Solid Waste Amendments (HSWA) of the 1984 United States Code (USC). The report provides a comprehensive inventory of all types of waste management units at the Hanford Site and consists of waste disposal units, including (1) Resource Conservation and Recovery Act of 1976 (RCRA) disposal units, (2) Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) disposal units, (3) unplanned releases, (4) inactive contaminated structures, (5) RCRA treatment and storage units, and (6) other storage areas. Because of the comprehensive nature of this report, the listing of sites is more extensive than required by Section 3004(u) of HSWA. In support of the Hanford RCRA permit, a field was added to designate whether the waste management unit is a solid waste management unit (SWMU). As SWMUs are identified, they will added to the Hanford Waste Information Data System (WIDS), which is the database supporting this report, and added to the report at its next annual update. A quality review of the WIDS was conducted this past year. The review included checking all data against their reference and making appropriate changes, updating the data elements using the most recent references, marking duplicate units for deletion, and adding additional information. 6 refs

  18. Generating units performances: power system requirements

    Energy Technology Data Exchange (ETDEWEB)

    Fourment, C; Girard, N; Lefebvre, H

    1994-08-01

    The part of generating units within the power system is more than providing power and energy. Their performance are not only measured by their energy efficiency and availability. Namely, there is a strong interaction between the generating units and the power system. The units are essential components of the system: for a given load profile the frequency variation follows directly from the behaviour of the units and their ability to adapt their power output. In the same way, the voltage at the units terminals are the key points to which the voltage profile at each node of the network is linked through the active and especially the reactive power flows. Therefore, the customer will experience the frequency and voltage variations induced by the units behaviour. Moreover, in case of adverse conditions, if the units do not operate as well as expected or trip, a portion of the system, may be the whole system, may collapse. The limitation of the performance of a unit has two kinds of consequences. Firstly, it may result in an increased amount of not supplied energy or loss of load probability: for example if the primary reserve is not sufficient, a generator tripping may lead to an abnormal frequency deviation, and load may have to be shed to restore the balance. Secondly, the limitation of a unit performance results in an economic over-cost for the system: for instance, if not enough `cheap` units are able to load-following, other units with higher operating costs have to be started up. We would like to stress the interest for the operators and design teams of the units on the one hand, and the operators and design teams of the system on the other hand, of dialog and information exchange, in operation but also at the conception stage, in order to find a satisfactory compromise between the system requirements and the consequences for the generating units. (authors). 11 refs., 4 figs.

  19. International law and United Nations

    Directory of Open Access Journals (Sweden)

    Savić Matej

    2012-01-01

    Full Text Available Along with centuries-lasting open military pretensions of world superpowers, modern diplomacy has developed, as beginning a war, as well as coming to peace demanded political activity which resulted, first in signing, and then coming into effect of international documents, on the basis of which, a foundation for the modern international order has been cast. Further on, by the formation of international organizations, codification has been allowed, as well as a progressive development of international law. Additionally, in the sense of preserving international peace and security, first the League of Nations was formed, and following the ending of World War II, the UN. Generally, the functioning of the United Nation's organs, has been regulated by legal rules, however political goals, tendencies, and mechanisms which the member states are using determine greatly the activity above all of the Security Council, but furthermore of the General Assembly, as a plenary organ. Nevertheless, the achieved results of the Commission for International Law in the meaning of creation of international conventions, as well as state adhering to the same, present unassailable achievements in the sense of development of international law. On the other hand, tendencies of motion of international relationships are aimed at establishing a multi-polar system in the international community. Today, the political scene is assuming a new appearance, by which the nearly built international system is already awaiting further progressive development.

  20. Decommissioning: a United Kingdom perspective

    International Nuclear Information System (INIS)

    Haworth, A.; Reed, D.L.; Bleeze, A.

    1995-01-01

    The paper considers the United Kingdom legislative framework relevant to decommissioning of facilities on nuclear licensed sites. It describes the various legislative bodies involved in regulating this activity and the inspectorate concerned. The licensing regime is described in some detail highlighting the UK arrangements whereby a license is granted for the site upon which nuclear facilities are planned or exist. The license remains in place throughout the life of the plant on the site: from initial planning through to the end of decommissioning. A site (of part of) is not de-licensed until it can be stated that there has ceased to be any danger from ionising radiations from anything on the site (or appropriate part of the site). The final part of the paper considers the changes arising from the commercialization of the nuclear power industry in UK and the restatement of the Nuclear Installation Inspectorate's policy on decommissioning which has arisen as a result of a review made in response to these changes. (author)

  1. Several hundred megawatt MHD units

    International Nuclear Information System (INIS)

    Pishchikov, S.; Pinkhasik, D.; Sidorov, V.

    1978-01-01

    The features are described of the future MHD unit U-25 tested at the Institute of High Temperatures of the Academy of Sciences of the USSR. The attainable thermal load of the combustion chamber is 290x10 6 kJ/m 3 .h. Three types of channel were tested, i.e., the Faraday channel divided into sections with modular insulating walls, the diagonal channel without metal body, and an improved Faraday channel with an output of 20 MW. The described MHD generator is equipped with an inverter which transforms direct current into alternating current, continuously adjusts the load from no-load operation to short-circuit connection and maintains the desired electrical voltage independently of the changes in loading. A new technique of connecting and disconnecting the oxygen equipment was developed which considerably reduces the time of start-up and shut-down. Natural gas is used for heating the air heaters. All equipment used in the operation of the MHD generator is remote controlled by computer or manually. (J.B.)

  2. Several hundred megawatt MHD units

    Energy Technology Data Exchange (ETDEWEB)

    Pishchikov, S; Pinkhasik, D; Sidorov, V

    1978-07-01

    The features are described of the future MHD unit U-25 tested at the Institute of High Temperatures of the Academy of Sciences of the USSR. The attainable thermal load of the combustion chamber is 290x10/sup 6/ kJ/m/sup 3/.h. Three types of channel were tested, i.e., the Faraday channel divided into sections with modular insulating walls, the diagonal channel without metal body, and an improved Faraday channel with an output of 20 MW. The described MHD generator is equipped with an inverter which transforms direct current into alternating current, continuously adjusts the load from no-load operation to short-circuit connection and maintains the desired electrical voltage independently of the changes in loading. A new technique of connecting and disconnecting the oxygen equipment was developed which considerably reduces the time of start-up and shut-down. Natural gas is used for heating the air heaters. All equipment used in the operation of the MHD generator is remote controlled by computer or manually.

  3. AREVA in the United States

    International Nuclear Information System (INIS)

    2007-01-01

    In 2005, the United States had 297 million inhabitants (the 3. most populous country in the world) and a land area of 9.4 million km 2 (17 times larger than France). With a GDP of 10,996 billion dollars (under the economic conditions of the year 2000), the U.S. is the largest economic power in the world. It is also the largest consumer of energy, with primary energy consumption of 2,329 million metric tons, meaning that 25% of the world's energy is consumed by just 4% of its population. Although it has large domestic energy supplies, the U.S. is very far from achieving energy self-sufficiency. A decline of nearly 50% in oil production over a period of more than 30 years and the simultaneous stagnation of gas production have further weakened the U.S. energy balance. On a more general level, the increasing depletion of hydrocarbon resources (gas and oil), the concentration of the world's main resources in geo-politically unstable areas and the forecasted increase in the consumption and price of hydrocarbons, especially since 2005, mean that energy independence and supply security have become 2 of the top priorities of U.S. commercial and international policy. In 2007, the U.S. accounted for 22% of global CO 2 emissions, equaling those of China. In relation to population, the U.S. emits 8 metric tons/inhabitant compared to a world average of 4.2 metric tons/inhabitant. Although global warming is seen as a reality by the American public, it has only recently become a major argument in favor of a nuclear energy revival in the U.S. The context is, however, changing significantly. This is evidenced by America's adoption, in recent years, of measures to reduce greenhouse gases, particularly through the development of new, more environmentally friendly technologies. Since 2001, nearly 23 billion dollars in public funds have been devoted to climate research and the development of clean energy sources, notably renewable energies such as wind and solar, but also hydrogen and

  4. Patient dose in neonatal units

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2008-01-01

    Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Hence, knowledge of the patient dose is necessary to justify the exposures. A study to assess the patient doses was started at the neonatal intensive care unit (NICU) of the Univ. Hospital in Leuven. Between September 2004 and September 2005, prematurely born babies underwent on average 10 X-ray examinations in the NICU. In this sample, the maximum was 78 X-ray examinations. For chest radiographs, the median entrance skin dose was 34 μGy and the median dose area product was 7.1 mGy.cm 2 . By means of conversion coefficients, the measured values were converted to organ doses. Organ doses were calculated for three different weight classes: extremely low birth weight infants ( 2500 g). The doses to the lungs for a single chest radiograph for infants with extremely low birth weights, low birth weights and normal birth weights were 24, 25 and 32 μGy, respectively. (authors)

  5. United Kingdom electric system privatization

    Energy Technology Data Exchange (ETDEWEB)

    Lolli, A. (Bologna Univ. (Italy))

    1992-03-01

    This paper reviews the mechanics and first results of deregulation in the electric power industry of the United Kingdom. Several aspects are dealt with, namely: 1983 Energy Act impacts on ownership and subsequent changes brought about by the 1989 Energy Act; the Act's stipulations with regard to share acquisition and distribution; the division of the patrimony of the Area Boards; natural monopolistic characteristics of power distribution; vertical integration in Scotland, target investment limits in Government and public participation; the 'golden share' concept to guarantee public participation; current 40% share ownership by the Government; 15% private ownership limit for individual investors; external control by Government of licensing and rate structure setting; the impacts of organizational changes on the overall cost benefits of deregulation; modified Governmental regulatory powers; measures to ensure competition and consumer protection; provisions regarding misbehaviour; second tier suppliers and reserve fuel supply obligations; deregulation impacts on nuclear power marketing; power pooling regulations; installation of new transmission lines; provisions encouraging the use of diverse energy sources; franchising; interconnection with national grid; regulation of technical operations; standby as it affects rate structure; and spot market pricing.

  6. Neurovascular Unit in Chronic Pain

    Directory of Open Access Journals (Sweden)

    Beatrice Mihaela Radu

    2013-01-01

    Full Text Available Chronic pain is a debilitating condition with major socioeconomic impact, whose neurobiological basis is still not clear. An involvement of the neurovascular unit (NVU has been recently proposed. In particular, the blood-brain barrier (BBB and blood-spinal cord barrier (BSCB, two NVU key players, may be affected during the development of chronic pain; in particular, transient permeabilization of the barrier is suggested by several inflammatory- and nerve-injury-based pain models, and we argue that the clarification of molecular BBB/BSCB permeabilization events will shed new light in understanding chronic pain mechanisms. Possible biases in experiments supporting this theory and its translational potentials are discussed. Moving beyond an exclusive focus on the role of the endothelium, we propose that our understanding of the mechanisms subserving chronic pain will benefit from the extension of research efforts to the NVU as a whole. In this view, the available evidence on the interaction between analgesic drugs and the NVU is here reviewed. Chronic pain comorbidities, such as neuroinflammatory and neurodegenerative diseases, are also discussed in view of NVU changes, together with innovative pharmacological solutions targeting NVU components in chronic pain treatment.

  7. Management information systems. [United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.; Spence, A.C.

    1985-02-01

    The successful application in the United Kingdom of the real time monitoring and control systems (MINOS) for underground mining operations, particularly in coal transport and the development of coalface monitoring (FIDO) in 1980 led naturally to the design of an operational data base for management. A User Group of experienced colliery managers produced a Management Information System (MIS) requirements specification and began the evolution of the systems of today. Twenty-four mines operate MIS in different ways from total dependency to a means of checking their manual reporting system. MIS collects useful data from all the major MINOS applications and provides a means of manually inputting other, relevant information. A wide variety of displays and reports are available to management, adjusted to meet individual requirements. The benefits from the use of MIS are difficult to quantify, since they become part of the management process. Further developments are taking place based on operational experience and requirements and taking advantage of the recent advances in computer technology. MIS is the modern management tool in British coal mining, collecting, storing, analysing and presenting accurate information upon which management decision making is based.

  8. AREVA in the United States

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    In 2005, the United States had 297 million inhabitants (the 3. most populous country in the world) and a land area of 9.4 million km{sup 2} (17 times larger than France). With a GDP of 10,996 billion dollars (under the economic conditions of the year 2000), the U.S. is the largest economic power in the world. It is also the largest consumer of energy, with primary energy consumption of 2,329 million metric tons, meaning that 25% of the world's energy is consumed by just 4% of its population. Although it has large domestic energy supplies, the U.S. is very far from achieving energy self-sufficiency. A decline of nearly 50% in oil production over a period of more than 30 years and the simultaneous stagnation of gas production have further weakened the U.S. energy balance. On a more general level, the increasing depletion of hydrocarbon resources (gas and oil), the concentration of the world's main resources in geo-politically unstable areas and the forecasted increase in the consumption and price of hydrocarbons, especially since 2005, mean that energy independence and supply security have become 2 of the top priorities of U.S. commercial and international policy. In 2007, the U.S. accounted for 22% of global CO{sub 2} emissions, equaling those of China. In relation to population, the U.S. emits 8 metric tons/inhabitant compared to a world average of 4.2 metric tons/inhabitant. Although global warming is seen as a reality by the American public, it has only recently become a major argument in favor of a nuclear energy revival in the U.S. The context is, however, changing significantly. This is evidenced by America's adoption, in recent years, of measures to reduce greenhouse gases, particularly through the development of new, more environmentally friendly technologies. Since 2001, nearly 23 billion dollars in public funds have been devoted to climate research and the development of clean energy sources, notably renewable energies such as wind and solar

  9. The Kozloduy project management unit

    International Nuclear Information System (INIS)

    Carnes, W.S.; Gros-Gean, P.; Demireva, E.

    2004-01-01

    The Project Management Unit (PMU) has been established in support to the Kozloduy NPP decommissioning department. It is comprised of a Consortium of the British Nuclear Group, EDF and subcontractor ENPRO Consult. It is responsible for the management of seven projects (a facility for dry storage of spent fuel; equipment to treat low activity liquid radioactive waste; provision of physical separation of the plant systems and areas to be decommissioned from the ones in operation; equipment to decontaminate and clean pools and large tanks; a facility to provide high volume reduction of solid radioactive wastes and retrieval and conditioning of ion exchange resins and other sorbents; equipment to provide measurement for the free-release of materials and components; a facility for personnel monitoring, decontamination and clothes changing for work outside of the normal radiological control areas) that will be used in support of the KNPP decommissioning process. The projects will be tendered in compliance with the European Bank for Reconstruction and Development requirements

  10. Data report: western United States

    International Nuclear Information System (INIS)

    Cook, J.R.; Fay, W.M.

    1982-04-01

    This abbreviated summary data report, presents results of ground water and stream surface sediment reconnaissance in the western United States. Surface sediment samples were collected at 67,741 sites, at a target sampling density of one site per 13 square kilometers. Ground water samples were collected at 13,979 sites, and surface water samples were collected at 2,958 sites. Neutron activaton analysis results are given for uranium and 16 other elements in sediments, and for uranium and 9 other elements in waters. Mass spectrometry results are given for helium in ground waters. Supplemental analyses of the sediments for extractable uranium and 22 other elements are given where they are available. Supplemental analyses of water samples for 33 additional elements are also reported where they are available. Analytical data and field measurements are presented in tables on microfiche. Data from ground water sites (on microfiche in pocket) include (1) water chemistry measurements (pH, conductivity, and alkalinity), (2) physical measurements where applicable (water temperature, well description, and scintillometer reading), and (3) elemental analyses (U, Al, Br Cl, Dy, F, Mg, Mn, Na, and V by neutron activation and Ag, Al, As, B, Ba, Be, Ca, Ce, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Nb, Ni, P, Sc, Se, Si, Sr, Th, Ti, V, Y, Zn, and Zr by spectrophotometry). Helium analyses are given for ground water

  11. The Unitality of Quantum B-algebras

    Science.gov (United States)

    Han, Shengwei; Xu, Xiaoting; Qin, Feng

    2018-02-01

    Quantum B-algebras as a generalization of quantales were introduced by Rump and Yang, which cover the majority of implicational algebras and provide a unified semantic for a wide class of substructural logics. Unital quantum B-algebras play an important role in the classification of implicational algebras. The main purpose of this paper is to construct unital quantum B-algebras from non-unital quantum B-algebras.

  12. Junior Leader Training Development in Operational Units

    Science.gov (United States)

    2012-04-01

    UNITS Successful operational units do not arise without tough, realistic, and challenging training. Field Manual (FM) 7-0, Training Units and D...operations. The manual provides junior leaders with guidance on how to conduct training and training management. Of particular importance is the definition...1 Relation htp between ADDIE and the Anny Training Management Model. The Army Training Management Model and ADDIE process appear in TRADOC PAM 350

  13. Fatigue in Breakwater Concrete Armour Units

    OpenAIRE

    Burcharth, Hans F.

    1984-01-01

    The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units. Results showing significant fatigue from impact tests with Dolosse made of unreinforced and steel fibre reinforced flyash concrete are presented. Moreover universal graphs for fatigue in armour units made of conventional unreinforced concrete exposed to impact load ...

  14. Seasonal unit roots in trade variables

    OpenAIRE

    Carol Alexander; Manuel Cantavella Jordá

    1997-01-01

    In this paper we examine the presence of seasonal unit roots in trade variables for Germany, France, the United Kingdom, and Italy, using the procedure developed by Hylleberg, Engle, Granger, and Yoo (1990) [HEGY]. Both quarterly and monthly data reject the presence of unit roots at most seasonal frequencies, more frequently in quarterly than in monthly data. This has important implications for econometric modeling of trade balance, exchange rates and income in European Union (EU) countries. ...

  15. Contemporary United States Foreign Policy Towards Indonesia

    National Research Council Canada - National Science Library

    McAslan, Hugh

    2004-01-01

    United States national interests in Indonesia have traditionally being based on strategic security requirements given Indonesia's geographic location between the Indian and Pacific Oceans, and strong...

  16. Polymeric Traypack Integrity: Bench-Scale Unit

    National Research Council Canada - National Science Library

    Canavan, Jeffrey

    2002-01-01

    .... Additional experimentation was conducted to determine the applicability of the unit for non-destructive residual gas testing since current destructive tests represent a substantial continuing expense...

  17. Stabilization of gas turbine unit power

    Science.gov (United States)

    Dolotovskii, I.; Larin, E.

    2017-11-01

    We propose a new cycle air preparation unit which helps increasing energy power of gas turbine units (GTU) operating as a part of combined cycle gas turbine (CCGT) units of thermal power stations and energy and water supply systems of industrial enterprises as well as reducing power loss of gas turbine engines of process blowers resulting from variable ambient air temperatures. Installation of GTU power stabilizer at CCGT unit with electric and thermal power of 192 and 163 MW, respectively, has resulted in reduction of produced electrical energy production costs by 2.4% and thermal energy production costs by 1.6% while capital expenditures after installation of this equipment increased insignificantly.

  18. Portable brine evaporator unit, process, and system

    Science.gov (United States)

    Hart, Paul John; Miller, Bruce G.; Wincek, Ronald T.; Decker, Glenn E.; Johnson, David K.

    2009-04-07

    The present invention discloses a comprehensive, efficient, and cost effective portable evaporator unit, method, and system for the treatment of brine. The evaporator unit, method, and system require a pretreatment process that removes heavy metals, crude oil, and other contaminates in preparation for the evaporator unit. The pretreatment and the evaporator unit, method, and system process metals and brine at the site where they are generated (the well site). Thus, saving significant money to producers who can avoid present and future increases in transportation costs.

  19. Logistics Support of Naval Expeditionary Units

    National Research Council Canada - National Science Library

    Nilsen, Jan

    2004-01-01

    .... Based on literature from strategic management, logistics, and supply chain management, the research evaluates the existing theater logistics capabilities and the requirements of the supported expeditionary units...

  20. Clinical Epidemiology Unit - overview of research areas

    Science.gov (United States)

    Clinical Epidemiology Unit (CEU) conducts etiologic research with potential clinical and public health applications, and leads studies evaluating population-based early detection and cancer prevention strategies

  1. GENDER ISSUES: Perceptions of Readiness in Selected Units

    National Research Council Canada - National Science Library

    1999-01-01

    .... More than 13,000 women have joined these units.3 Among the units that have opened to women are Army smoke and chemical companies, forward support battalions, air defense artillery headquarters' units, military police units, and engineer companies...

  2. TRAINING OF THE STATE PRESIDENT'S UNIT

    African Journals Online (AJOL)

    The primary function of the State President's Unit is to protect the head of state - not his person as is generally believed, but his authority over the state. Ironically, the ceremonial performances of the State President's Unit lead people to believe that they are only capable of doing drill exer- cises. However, upon investigating.

  3. 40 CFR 157.27 - Unit packaging.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Unit packaging. 157.27 Section 157.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PACKAGING REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.27 Unit packaging. Pesticide products...

  4. Organizational evaluation of an interprofessional study unit

    DEFF Research Database (Denmark)

    Jensen, Didde Cramer; Nørgaard, Birgitte; Draborg, Eva

    2012-01-01

    This article presents results from an organizational evaluation of an interprofessional clinical study unit (ICS) in Denmark. The aim of this study was to test whether the ICS was based on a durable organizational concept and to identify the prerequisites for the unit to be successful...

  5. Global Entrepreneurship and the United States

    Science.gov (United States)

    2010-09-01

    Global Entrepreneurship and the United States by Zoltan J. Acs Laszlo Szerb Ruxton, MD 21204 for under contract number SBAHQ-09...SUBTITLE Global Entrepreneurship and the United States 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...3 2.1. Assessing Entrepreneurship ..................................................................................4 2.2. Stages of Development

  6. Charpak, Garwin, propose unit for radiation dose

    CERN Multimedia

    Feder, Toni

    2002-01-01

    Becquerels, curries, grays, rads, rems, roentgens, sieverts - even for specialists the units of radiation can get confusing. That's why two eminent physicists, Georges Charpak of France, and Richard Garwin, are proposing the DARI as a unit of radiation dose they hope will help the public evaluate the risks associated with low-level radiation exposure (1 page)

  7. Block Gas Sol Unit in Haderslev

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    2000-01-01

    Investigation of a SDHW system based on a Block Gas Sol Unit from Baxi A/S installed by a consumer i Haderslev, Denmark.......Investigation of a SDHW system based on a Block Gas Sol Unit from Baxi A/S installed by a consumer i Haderslev, Denmark....

  8. Traditional African Religion: A Resource Unit.

    Science.gov (United States)

    Garland, William E.

    This resource unit is based on research conducted by Lynn Mitchell and Ernest Valenzuela, experienced classroom teachers of African history and culture. The unit consists of an introduction by Mr. Garland and two major parts. Part I is an annotated bibliography of selected sources on various aspects of traditional African Religion useful in…

  9. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  10. Unit labour costs, productivity and international competitiveness

    NARCIS (Netherlands)

    Ark, Bart van; Stuivenwold, Edwin; Ypma, Gerard

    2005-01-01

    This paper provides international comparisons of relative levels of unit labour costs (ULC) for several OECD countries relative to the United States. The estimates are based on the Total Economy Database and the 60-Industry Database of the Groningen Growth and Development Centre (GGDC), and are also

  11. United States housing, first quarter 2013

    Science.gov (United States)

    Delton Alderman

    2014-01-01

    Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing under construction, and housing completions for single and multifamily units, and sales and construction. This report will be updated regularly.

  12. 78 FR 64385 - United Nations Day, 2013

    Science.gov (United States)

    2013-10-28

    ... A Proclamation In 1945, after two world wars that showed the horrific lethality of modern conflict.... We celebrate the organization's challenging and often unheralded work of forging a world in which... children and grandchildren from the ravages of war, the members of the United Nations committed ``to unite...

  13. An intersection test for panel unit roots

    NARCIS (Netherlands)

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  14. National Lexicography Units: Past, Present, Future

    African Journals Online (AJOL)

    Mariëtta Alberts, Research Unit for Languages and Literature in SA Context,. Northwest ..... NLUs were also assisted with the marketing of the units and the obtaining .... each dictionary project, and developing an editorial style guide for each dic- .... The DSAE edited the South African Concise Oxford Dictionary that was.

  15. Oversight Institutions Within the United Nations

    DEFF Research Database (Denmark)

    Pontoppidan, Caroline Aggestam

    2015-01-01

    This article will give a description of the role of internal audit and governance functions within the United Nations system. The United Nations has, during the last 10 years, worked to establish effective oversight services. Oversight, governance and hereunder the internal audit function has been...

  16. Performance and burnout in intensive care units

    NARCIS (Netherlands)

    Keijsers, GJ; Schaufeli, WB; LeBlanc, P; Zwerts, C; Miranda, DR

    1995-01-01

    The relationship between three different performance measures and burnout was explored in 20 Dutch Intensive Care Units (ICUs). Burnout (i.e. emotional exhaustion and depersonalization) proved to be significantly related to nurses' perceptions of performance as well as to objectively assessed unit

  17. Physical protection of nuclear operational units

    International Nuclear Information System (INIS)

    1981-07-01

    The general principles of and basic requirements for the physical protection of operational units in the nuclear field are established. They concern the operational units whose activities are related with production, utilization, processing, reprocessing, handling, transport or storage of materials of interest for the Brazilian Nuclear Program. (I.C.R.) [pt

  18. 7 CFR 275.6 - Management units.

    Science.gov (United States)

    2010-01-01

    ... FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Management Evaluation (ME... management unit; (iii) Food Stamp Program participation, including the number of persons and number of... 7 Agriculture 4 2010-01-01 2010-01-01 false Management units. 275.6 Section 275.6 Agriculture...

  19. How Do We Really Compute with Units?

    Science.gov (United States)

    Fiedler, B. H.

    2010-01-01

    The methods that we teach students for computing with units of measurement are often not consistent with the practice of professionals. For professionals, the vast majority of computations with quantities of measure are performed within programs on electronic computers, for which an accounting for the units occurs only once, in the design of the…

  20. Unit roots, nonlinearities and structural breaks

    DEFF Research Database (Denmark)

    Haldrup, Niels; Kruse, Robinson; Teräsvirta, Timo

    One of the most influential research fields in econometrics over the past decades concerns unit root testing in economic time series. In macro-economics much of the interest in the area originate from the fact that when unit roots are present, then shocks to the time series processes have...

  1. 75 FR 65561 - United Nations Day, 2010

    Science.gov (United States)

    2010-10-26

    ... A Proclamation Sixty-five years ago, 51 nations came together in the aftermath of one of history's... all peoples. The United Nations has made great advances since it first developed out of ruin and... of nations. The United Nations' humanitarian assistance lifts up countless lives, supporting nations...

  2. Understanding "Romeo and Juliet": A Thematic Unit.

    Science.gov (United States)

    Koveleski, Erin

    This curriculum unit for Grade 9 combines the classic Shakespeare play "Romeo and Juliet" with three young adult novels: "The Outsiders" (S.E. Hinton), "Summer of My German Soldier" (Bette Greene), and "The Witch of Blackbird Pond" (Elizabeth George Speare). To complete the unit, all students will be…

  3. The Carnegie Unit: Past, Present, and Future

    Science.gov (United States)

    Silva, Elena; White, Taylor

    2015-01-01

    For more than a century, the Carnegie Unit has been the central organizing feature of American education. Translated into the "credit hour" in higher education (roughly, one hour of class time per week in a 14-16 week semester), this time-based unit is embedded in nearly every aspect of the system, from faculty-workload and…

  4. Improper colouring of (random) unit disk graphs

    NARCIS (Netherlands)

    Kang, R.J.; Müller, T.; Sereni, J.S.

    2008-01-01

    For any graph G, the k-improper chromatic number ¿k(G) is the smallest number of colours used in a colouring of G such that each colour class induces a subgraph of maximum degree k. We investigate ¿k for unit disk graphs and random unit disk graphs to generalise results of McDiarmid and Reed

  5. 28 CFR 0.1 - Organizational units.

    Science.gov (United States)

    2010-07-01

    ... Legal Policy. Office of Public Affairs. Office of the Pardon Attorney. Office of Special Counsel for Immigration Related Unfair Employment Practices. Community Relations Service. Executive Office for Immigration Review. Executive Office for United States Attorneys. Executive Office for United States Trustees...

  6. Chinese Dragons in an American Science Unit

    Science.gov (United States)

    Lew, Lee Yuen; McLure, John W.

    2005-01-01

    Can art and science find a happy home in the same unit? We think the answer is yes, if the central problem interests the students and allows them to try out multiple abilities. The sixth-grade unit described in this article, which we called "The Dragon Project," grew mainly from two roots, a study of ancient China and a later probe into…

  7. "Units of Comparison" across Languages, across Time

    Science.gov (United States)

    Thomas, Margaret

    2009-01-01

    Lardiere's keynote article adverts to a succession of "units of comparison" that have been employed in the study of cross-linguistic differences, including mid-twentieth-century structural patterns, generative grammar's parameters, and (within contemporary Minimalism) features. This commentary expands on the idea of units of cross-linguistic…

  8. The United Nations and Its Critics.

    Science.gov (United States)

    Menon, Bhaskar P.

    1989-01-01

    Provides a brief history of the development of the United Nations. Identifies achievements of the United Nations in the promotion of human rights, the translation of the Universal Declaration of Human Rights into binding international covenants, and the establishment of monitoring mechanisms to ensure the protection of human rights. (KO)

  9. SPOKEN AYACUCHO QUECHUA, UNITS 11-20.

    Science.gov (United States)

    PARKER, GARY J.; SOLA, DONALD F.

    THE ESSENTIALS OF AYACUCHO GRAMMAR WERE PRESENTED IN THE FIRST VOLUME OF THIS SERIES, SPOKEN AYACUCHO QUECHUA, UNITS 1-10. THE 10 UNITS IN THIS VOLUME (11-20) ARE INTENDED FOR USE IN AN INTERMEDIATE OR ADVANCED COURSE, AND PRESENT THE STUDENT WITH LENGTHIER AND MORE COMPLEX DIALOGS, CONVERSATIONS, "LISTENING-INS," AND DICTATIONS AS WELL…

  10. SPOKEN COCHABAMBA QUECHUA, UNITS 1-12.

    Science.gov (United States)

    LASTRA, YOLANDA; SOLA, DONALD F.

    THE FIRST OF TWO VOLUMES PREPARED FOR TEACHING THE COCHABAMBA DIALECT OF QUECHUA TO SPEAKERS OF ENGLISH, THIS DOCUMENT IS MADE UP OF 12 UNITS THAT COMPRISE A 6-WEEK INTENSIVE COURSE OF 20 CLASS HOURS A WEEK. EACH UNIT CONSISTS OF ONE OR MORE DIALOGS TO BE MEMORIZED, A DIALOG REVIEW, A SECTION ON GRAMMAR WITH ACCOMPANYING EXERCISES, CONVERSATION,…

  11. SPOKEN COCHABAMBA QUECHUA, UNITS 13-24.

    Science.gov (United States)

    LASTRA, YOLANDA; SOLA, DONALD F.

    UNITS 13-24 OF THE SPOKEN COCHABAMBA QUECHUA COURSE FOLLOW THE GENERAL FORMAT OF THE FIRST VOLUME (UNITS 1-12). THIS SECOND VOLUME IS INTENDED FOR USE IN AN INTERMEDIATE OR ADVANCED COURSE AND INCLUDES MORE COMPLEX DIALOGS, CONVERSATIONS, "LISTENING-INS," AND DICTATIONS, AS WELL AS GRAMMAR AND EXERCISE SECTIONS COVERING ADDITIONAL…

  12. Unit: Plants, Inspection Pack, National Trial Print.

    Science.gov (United States)

    Australian Science Education Project, Toorak, Victoria.

    This is a National Trial Print of a unit on plants produced as a part of the Australian Science Education Project. The unit consists of an information booklet for students, a booklet for recording student data, and a teacher's guide. The material, designed for use with students in the upper elementary grades, takes from 15 to 20 forty-minute…

  13. Unit 148 - World Wide Web Basics

    OpenAIRE

    148, CC in GIScience; Yeung, Albert K.

    2000-01-01

    This unit explains the characteristics and the working principles of the World Wide Web as the most important protocol of the Internet. Topics covered in this unit include characteristics of the World Wide Web; using the World Wide Web for the dissemination of information on the Internet; and using the World Wide Web for the retrieval of information from the Internet.

  14. Topology optimization of inertia driven dosing units

    DEFF Research Database (Denmark)

    Andreasen, Casper Schousboe

    2017-01-01

    This paper presents a methodology for optimizing inertia driven dosing units, sometimes referred to as eductors, for use in small scale flow applications. The unit is assumed to operate at low to moderate Reynolds numbers and under steady state conditions. By applying topology optimization...

  15. An Environmental Unit for the Social Studies.

    Science.gov (United States)

    Kroll, Claudia J.

    Based on the inquiry method of learning, this instructional unit attempts to encourage students to discover for themselves the facts, problems, values, conflicts, and potential solutions of an environmental issue. Specifically, it deals with surface mining in the United States, with special focus on surface mining in Illinois. Materials and…

  16. Stresses in Dolos Breakwater Armour Units

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1991-01-01

    Breakage of slender unreinforced armour unite is the cause of many breakwater failures. Design diagrams to ensure structural integrity of armour unite such as dolosse and tetrapods have not been available. The article presents results of an analysis of the stresses in dolosse based on model tests...

  17. Portable Power And Digital-Communication Units

    Science.gov (United States)

    Levin, Richard R.; Henry, Paul K.; Rosenberg, Leigh S.

    1992-01-01

    Conceptual network of electronic-equipment modules provides electrical power and digital radio communications at multiple sites not served by cables. System includes central communication unit and portable units powered by solar photovoltaic arrays. Useful to serve equipment that must be set up quickly at remote sites or buildings that cannot be modified to provide cable connections.

  18. Immigration Enforcement Within the United States

    Science.gov (United States)

    2006-04-06

    Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Policy Issues...Remained in the United States, (Washington: Center for Immigration Studies, May 2002). Immigration Enforcement Within the United States Introduction ...interior enforcement lack a border component. For example, fugitive taskforces, investigations of alien slavery and sweatshops , and employer sanctions do

  19. Socioeconomic Development Inequalities among Geographic Units ...

    African Journals Online (AJOL)

    Socio-economic development inequality among geographic units is a phenomenon common in both the developed and developing countries. Regional inequality may result in dissension among geographic units of the same state due to the imbalance in socio-economic development. This study examines the inequality ...

  20. 75 FR 25925 - United States Mint

    Science.gov (United States)

    2010-05-10

    ... Committee May 25, 2010 Public Meeting. SUMMARY: Pursuant to United States Code, Title 31, section 5135(b)(8... scheduled for May 25, 2010. Date: May 25, 2010. Time: 9 a.m. to 12 p.m. Location: 8th Floor Board Room, United States Mint, 801 9th Street, NW., Washington, DC 20220. Subject: Review and discuss obverse and...

  1. Anti-Terrorism Authority Under the Laws of the United Kingdom and the United States

    National Research Council Canada - National Science Library

    Feikert, Clare; Doyle, Charles

    2006-01-01

    This is a comparison of the laws of the United Kingdom and of the United States that govern criminal and intelligence investigations of terrorist activities Both systems rely upon a series of statutory authorizations...

  2. Intelligent multi-unit disk controller

    International Nuclear Information System (INIS)

    Poirot, Lucien

    1982-01-01

    This controller has been designed as a link between a 16 bits minicomputer and two types of disks units interface: the SMD interface and an equivalent to the DRI unit interface. Four units of each type can be handled by the controller. A bit slice microprocessor controls the interface with the disks units. The maximum exchange rate is 8 megabits per second. A CRC feature has been provided for error detection. A 16 bits microprocessor implements the interface to the computer, assuring head positioning, the management of bad tracks, as well as the supervision of each transfer. A internal buffer memory allows an asynchronous dialogue with the computer. The implementation of the controller makes easy the adaptation to disks units of various types, and though it has been initially intended for a minicomputer of the MITRA type, its microprocessor based design makes it fitted to any minicomputer. (author) [fr

  3. A computer controlled tele-cobalt unit

    International Nuclear Information System (INIS)

    Brace, J.A.

    1982-01-01

    A computer controlled cobalt treatment unit was commissioned for treating patients in January 1980. Initially the controlling computer was a minicomputer, but now the control of the therapy unit is by a microcomputer. The treatment files, which specify the movement and configurations necessary to deliver the prescribed dose, are produced on the minicomputer and then transferred to the microcomputer using minitape cartridges. The actual treatment unit is based on a standard cobalt unit with a few additional features e.g. the drive motors can be controlled either by the computer or manually. Since the treatment unit is used for both manual and automatic treatments, the operational procedure under computer control is made to closely follow the manual procedure for a single field treatment. The necessary safety features which protect against human, hardware and software errors as well as the advantages and disadvantages of computer controlled radiotherapy are discussed

  4. Cultural traits as units of analysis.

    Science.gov (United States)

    O'Brien, Michael J; Lyman, R Lee; Mesoudi, Alex; VanPool, Todd L

    2010-12-12

    Cultural traits have long been used in anthropology as units of transmission that ostensibly reflect behavioural characteristics of the individuals or groups exhibiting the traits. After they are transmitted, cultural traits serve as units of replication in that they can be modified as part of an individual's cultural repertoire through processes such as recombination, loss or partial alteration within an individual's mind. Cultural traits are analogous to genes in that organisms replicate them, but they are also replicators in their own right. No one has ever seen a unit of transmission, either behavioural or genetic, although we can observe the effects of transmission. Fortunately, such units are manifest in artefacts, features and other components of the archaeological record, and they serve as proxies for studying the transmission (and modification) of cultural traits, provided there is analytical clarity over how to define and measure the units that underlie this inheritance process.

  5. Stroke Unit: General principles and standards

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2015-04-01

    Full Text Available Evidence-based medicinal methods have convincingly shown that stroke unit approach reduces mortality and disability rates, improves the quality of life and economic burden resulting from acute ischemic and hemorrhagic stroke. Any contemporary stroke system of care cannot be successful without putting the stroke unit concept in the center of its organization. Stroke units are the main elements of primary and comprehensive stroke centers. As a modernization process, this article focuses on practical issues and suggestions related to integration of the stroke unit approach to a regionally organized stroke system of care for perusal by not only national health authorities and service providers, but also neurologists. Stroke unit quality metrics revisited herein are of critical importance for hospitals establishing or renovating primary and comprehensive stroke centers.

  6. Understanding nursing units with data and theory.

    Science.gov (United States)

    Diers, Donna; Hendrickson, Karrie; Rimar, Joan; Donovan, Donna

    2013-01-01

    Nursing units are social systems whose function depends on many variables. Available nursing data, combined with a theory of organizational diagnosis, can be used to understand nursing unit performance. One troubled unit served as a case study in organizational diagnosis and treatment using modern methods of data mining and performance improvement. Systems theory did not prescribe how to fix an underbounded system. The theory did suggest, however, that addressing the characteristics of overbounded and underbounded systems can provide some order and structure and identify helpful resources. In this instance, the data analysis served to help define the unit's problems in conjunction with information gained from talking with the nurses and touring the unit, but it was the theory that gave hints for direction for change.

  7. Mobile vapor recovery and vapor scavenging unit

    International Nuclear Information System (INIS)

    Stokes, C.A.; Steppe, D.E.

    1991-01-01

    This patent describes a mobile anti- pollution apparatus, for the recovery of hydrocarbon emissions. It comprises a mobile platform upon which is mounted a vapor recovery unit for recovering vapors including light hydrocarbons, the vapor recovery unit having an inlet and an outlet end, the inlet end adapted for coupling to an external source of hydrocarbon vapor emissions to recover a portion of the vapors including light hydrocarbons emitted therefrom, and the outlet end adapted for connection to a means for conveying unrecovered vapors to a vapor scavenging unit, the vapor scavenging unit comprising an internal combustion engine adapted for utilizing light hydrocarbon in the unrecovered vapors exiting from the vapor recovery unit as supplemental fuel

  8. 28 CFR 541.49 - Review of control unit placement.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Review of control unit placement. 541.49... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.49 Review of control unit placement. (a) Unit staff shall evaluate informally and daily an inmate's adjustment within the control unit...

  9. Entomology Unit annual report 2002

    International Nuclear Information System (INIS)

    2002-01-01

    order to support this activity a prototype container rearing system was designed and constructed. The successful development of the TPU3 system for tsetse rearing enables this approach to be evaluated. The container has now been placed at Seibersdorf and it will be used for rearing tsetse in 2003. For areawide tsetse SIT programmes it will be essential that an aerial fly release system is developed and a prototype release mechanism has been designed and built. However, for such a system to be operational tsetse will have to be immobilized for some time at low temperature and a suitable temperature regime is being identified. During 2002, a start was made on the renovation of part of the Unit to provide a rearing facility for mosquitoes. The renovations will be completed in the first half of 2003 following which a colony of Anopheles arabiensis will be established

  10. Violence in the United States

    Science.gov (United States)

    Sumner, Steven A.; Mercy, James A.; Dahlberg, Linda L.; Hillis, Susan D.; Klevens, Joanne; Houry, Debra

    2015-01-01

    IMPORTANCE Interpersonal violence, which includes child abuse and neglect, youth violence, intimate partner violence, sexual violence, and elder abuse, affects millions of US residents each year. However, surveillance systems, programs, and policies to address violence often lack broad, cross-sector collaboration, and there is limited awareness of effective strategies to prevent violence. OBJECTIVES To describe the burden of interpersonal violence in the United States, explore challenges to violence prevention efforts and to identify prevention opportunities. DATA SOURCES We reviewed data from health and law enforcement surveillance systems including the National Vital Statistics System, the Federal Bureau of Investigation’s Uniform Crime Reports, the US Justice Department’s National Crime Victimization Survey, the National Survey of Children’s Exposure to Violence, the National Child Abuse and Neglect Data System, the National Intimate Partner and Sexual Violence Survey, the Youth Risk Behavior Surveillance System, and the National Electronic Injury Surveillance System—All Injury Program. RESULTS Homicide rates have decreased from a peak of 10.7 per 100 000 persons in 1980 to 5.1 per 100 000 in 2013. Aggravated assault rates have decreased from a peak of 442 per 100 000 in 1992 to 242 per 100 000 in 2012. Nevertheless, annually, there are more than 16 000 homicides and 1.6 million nonfatal assault injuries requiring treatment in emergency departments. More than 12 million adults experience intimate partner violence annually and more than 10 million children younger than 18 years experience some form of maltreatment from a caregiver, ranging from neglect to sexual abuse, but only a small percentage of these violent incidents are reported to law enforcement, health care clinicians, or child protective agencies. Moreover, exposure to violence increases vulnerability to a broad range of mental and physical health problems over the life course; for example

  11. Register of basic residential units and spatial units in the Slovak Republic

    International Nuclear Information System (INIS)

    Galdik, S.; Vavrinec, B.

    2005-01-01

    In this contribution authors deal with the register of basic residential units and spatial units in the Slovak Republic. Classification of statistical territorial units is presented. Map data and statistical data contain information about environmental impact of industrial and energetic mills

  12. Units of measurement past, present and future international system of units

    CERN Document Server

    Gupta, S V

    2010-01-01

    It is for the first time that the subject of quantities and their respective units is dealt this much in detail a glimpse of units of measurements of base quantities of length, time, mass and volume is given for ancient India three and four dimensional systems of measurement units are critically examined establishment of the fact that only four base units are needed to describe a system of units the basics to arrive at the unit of a derived quantity are explained basic, derived and dimensionless quantities including quantity calculus are introduced life history of scientists concerned with measurements units are presented to be inspiring to working metrologists and students. The International System of Units including, Metre Convention Treaty and its various organs including International National of Weights and Measure are described. The realisation of base units is given in detail. Classes of derived units within the SI, units permitted for time to come, units outside SI but used in special fields of measur...

  13. Cross Selling Implementation From Outpatient Unit to Radiology Unit in Semen Gresik Hospital

    OpenAIRE

    Rochmah, Thinni Nurul; Faradisa, Mutiara Ayu

    2013-01-01

    Thelow visitingnumberinhospital€™sunitarecloselyrelatedtomarketingactivities,includinginternal marketing which consistsof cross sellingfromother units.Thisstudy aims toanalyze crossselling implementation from Outpatient Unit to Radiology Unit in Semen Gresik Hospital. This study was a cross sectional analytic design. Samplewastakenbysimple random samplingwithsamplesize25respondents.Independentvariableswere marketing policy,employee commitment,perception, motivation,andreadiness ofcross sellin...

  14. Simulation of motor unit recruitment and microvascular unit perfusion: spatial considerations.

    Science.gov (United States)

    Fuglevand, A J; Segal, S S

    1997-10-01

    Muscle fiber activity is the principal stimulus for increasing capillary perfusion during exercise. The control elements of perfusion, i.e., microvascular units (MVUs), supply clusters of muscle fibers, whereas the control elements of contraction, i.e., motor units, are composed of fibers widely scattered throughout muscle. The purpose of this study was to examine how the discordant spatial domains of MVUs and motor units could influence the proportion of open capillaries (designated as perfusion) throughout a muscle cross section. A computer model simulated the locations of perfused MVUs in response to the activation of up to 100 motor units in a muscle with 40,000 fibers and a cross-sectional area of 100 mm2. The simulation increased contraction intensity by progressive recruitment of motor units. For each step of motor unit recruitment, the percentage of active fibers and the number of perfused MVUs were determined for several conditions: 1) motor unit fibers widely dispersed and motor unit territories randomly located (which approximates healthy human muscle), 2) regionalized motor unit territories, 3) reversed recruitment order of motor units, 4) densely clustered motor unit fibers, and 5) increased size but decreased number of motor units. The simulations indicated that the widespread dispersion of motor unit fibers facilitates complete capillary (MVU) perfusion of muscle at low levels of activity. The efficacy by which muscle fiber activity induced perfusion was reduced 7- to 14-fold under conditions that decreased the dispersion of active fibers, increased the size of motor units, or reversed the sequence of motor unit recruitment. Such conditions are similar to those that arise in neuromuscular disorders, with aging, or during electrical stimulation of muscle, respectively.

  15. Assessment of Motor Units in Neuromuscular Disease.

    Science.gov (United States)

    Henderson, Robert D; McCombe, Pamela A

    2017-01-01

    The motor unit comprises the anterior horn cell, its axon, and the muscle fibers that it innervates. Although the true number of motor units is unknown, the number of motor units appears to vary greatly between different muscles and between different individuals. Assessment of the number and function of motor units is needed in diseases of the anterior horn cell and other motor nerve disorders. Amyotrophic lateral sclerosis is the most important disease of anterior horn cells. The need for an effective biomarker for assessing disease progression and for use in clinical trials in amyotrophic lateral sclerosis has stimulated the study of methods to measure the number of motor units. Since 1970 a number of different methods, including the incremental, F-wave, multipoint, and statistical methods, have been developed but none has achieved widespread applicability. Two methods (MUNIX and the multipoint incremental method) are in current use across multiple centres and are discussed in detail in this review, together with other recently published methods. Imaging with magnetic resonance and ultrasound is increasingly being applied to this area. Motor unit number estimates have also been applied to other neuromuscular diseases such as spinal muscular atrophy, compression neuropathies, and prior poliomyelitis. The need for an objective measure for the assessment of motor units remains tantalizingly close but unfulfilled in 2016.

  16. Nuclear development in the United States

    International Nuclear Information System (INIS)

    Brewer, S.

    1983-01-01

    The history of the nuclear development in the United States has been one of international cooperation relations so far. The United States is to offer the technical information on atomic energy utilization to foreign countries in exchange for the guarantee that they never attempt to have or develop nuclear weapons. Actually, the United States has supplied the technologies on nuclear fuel cycle and other related fields to enable other countries to achieve economical and social progress. The Department of Energy clarified the public promise of the United States regarding the idea of international energy community. The ratio of nuclear power generation to total electric power supply in the United States exceeded 12%, and will exceed 20% by 1990. Since 1978, new nuclear power station has not been ordered, and some of the contracted power stations were canceled. The atomic energy industry in the United States prospered at the beginning of 1970s, but lost the spirit now, mainly due to the institutional problems rather than the technical ones. As the policy of the government to eliminate the obstacles, the improvement of the procedure for the permission and approval, the establishment of waste disposal capability, the verification of fast breeder reactor technology and the promotion of commercial fuel reprocessing were proposed. The re-establishment of the United States as the reliable supplier of atomic energy service is the final aim. (Kako, I.)

  17. Practical unit testing with JUnit and Mockito

    CERN Document Server

    Kaczanowski, Tomek

    2013-01-01

    This book explains in detail how to implement unit tests using two very popular open source Java technologies: JUnit and Mockito. It presents a range of techniques necessary to write high quality unit tests - e.g. mocks, parametrized tests and matchers. It also discusses trade-offs related to the choices we have to make when dealing with some real-life code issues. The book stresses the importance of writing readable and maintainable unit tests, and puts a lot of stress on code quality. It shows how to achieve testable code and to eliminate common mistakes by following the Test Driven Development approach. Every topic discussed in the book is illustrated with code examples, and each chapter is accompanied by some exercises. By reading this book you will: Grasp the role and purpose of unit tests Write high-quality, readable and maintainable unit tests Learn how to use JUnit and Mockito (but also other useful tools) Avoid common pitfalls when writing unit tests Recognize bad unit tests, a...

  18. SmartUnit: Empirical Evaluations for Automated Unit Testing of Embedded Software in Industry

    OpenAIRE

    Zhang, Chengyu; Yan, Yichen; Zhou, Hanru; Yao, Yinbo; Wu, Ke; Su, Ting; Miao, Weikai; Pu, Geguang

    2018-01-01

    In this paper, we aim at the automated unit coverage-based testing for embedded software. To achieve the goal, by analyzing the industrial requirements and our previous work on automated unit testing tool CAUT, we rebuild a new tool, SmartUnit, to solve the engineering requirements that take place in our partner companies. SmartUnit is a dynamic symbolic execution implementation, which supports statement, branch, boundary value and MC/DC coverage. SmartUnit has been used to test more than one...

  19. Reform of the United Kingdom judicial system

    Directory of Open Access Journals (Sweden)

    Ovidiu-Horia MAICAN

    2013-12-01

    Full Text Available The separation of powers in a state is an essential characteristic of every democratic country, a principle present in many constitutions, most notably that of the United States. The concept is imperfectly fulfilled in the United Kingdom, given that the executive (Ministers form part of the legislature and that part of the judiciary (Law Lords sit in the legislature. As a result, it was necessary to remove the constitutional anomaly that the highest court of appeal in the United Kingdom was situated within one of the chambers of Parliament.

  20. A Nonparametric Test for Seasonal Unit Roots

    OpenAIRE

    Kunst, Robert M.

    2009-01-01

    Abstract: We consider a nonparametric test for the null of seasonal unit roots in quarterly time series that builds on the RUR (records unit root) test by Aparicio, Escribano, and Sipols. We find that the test concept is more promising than a formalization of visual aids such as plots by quarter. In order to cope with the sensitivity of the original RUR test to autocorrelation under its null of a unit root, we suggest an augmentation step by autoregression. We present some evidence on the siz...

  1. Incident Command System - Environmental Unit responsibilities

    International Nuclear Information System (INIS)

    Hillman, S. O.

    1997-01-01

    The Incident Command System (ICS) for crisis management, used for response to oil spills by the Alyeska Pipeline Service Company throughout its facilities, including the Trans Alaska Pipeline and the Valdez Marine Terminal, was described. Special attention was given to the Environmental Unit within the ICS which functions as a primary support unit for the Incident Operations Section. Details of the Unit's function were provided. These include the collection, evaluation and dissemination of information on all environmental issues concerning the crisis, provision of advice and direction on environmental aspects, and up-front agency interaction. A checklist of tasks is included. 7 refs

  2. Practice development units: a study of teamwork.

    Science.gov (United States)

    Walsh, M; Walsh, A

    In this report of a study using the Team Climate Inventory (TCI) tool, the researchers explain how the tool can be used in preparation for creating a practice development unit (PDU). The TCI provides a picture of the level and quality of teamwork in a unit using a series of Likert scales. The ward in this study was found to lack the necessary level of teamwork for successful PDU development and the researchers show how this information shaped trust plans. They recommend that units contemplating PDU accreditation should assess their level of teamwork prior to proceeding with bids.

  3. Household pesticide usage in the United States.

    Science.gov (United States)

    Savage, E P; Keefe, T J; Wheeler, H W; Mounce, L; Helwic, L; Applehans, F; Goes, E; Goes, T; Mihlan, G; Rench, J; Taylor, D K

    1981-01-01

    A total of 10,000 U.S. households in 25 standard metropolitan statistical areas and 25 counties were included in the United States. More than 8,200 households granted an interview. Nine of every ten households in the United States used some types of pesticide in their house, garden, or yard. Households in the southeastern United States used the most pesticides. Although more than 500 different pesticide formulations were used by the sampled households, 15 pesticides accounted for 65.5% of all pesticides reported in this study. Thirteen of these 15 pesticides were insecticides, one was a herbicide, and one was a rodenticide.

  4. Estimated United States Transportation Energy Use 2005

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C A; Simon, A J; Belles, R D

    2011-11-09

    A flow chart depicting energy flow in the transportation sector of the United States economy in 2005 has been constructed from publicly available data and estimates of national energy use patterns. Approximately 31,000 trillion British Thermal Units (trBTUs) of energy were used throughout the United States in transportation activities. Vehicles used in these activities include automobiles, motorcycles, trucks, buses, airplanes, rail, and ships. The transportation sector is powered primarily by petroleum-derived fuels (gasoline, diesel and jet fuel). Biomass-derived fuels, electricity and natural gas-derived fuels are also used. The flow patterns represent a comprehensive systems view of energy used within the transportation sector.

  5. Fatigue in Breakwater Concrete Armour Units

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1985-01-01

    The reliability of rubble mound breakwaters depends on the hydraulic stability and the mechanical strength of the armour units. The paper deals with the important aspect of fatigue related to the strength of concrete armour units. Results showing significant fatigue from impact tests with Dolosse...... made of unreinforced and steel fibre reinforced flyash concrete are presented. Moreover universal graphs for fatigue in armour units made of conventional unreinforced concrete exposed to impact load and pulsating load are presented. The effect of fibre reinforcement and the implementation of fatigue...

  6. Multiperiod Maximum Loss is time unit invariant.

    Science.gov (United States)

    Kovacevic, Raimund M; Breuer, Thomas

    2016-01-01

    Time unit invariance is introduced as an additional requirement for multiperiod risk measures: for a constant portfolio under an i.i.d. risk factor process, the multiperiod risk should equal the one period risk of the aggregated loss, for an appropriate choice of parameters and independent of the portfolio and its distribution. Multiperiod Maximum Loss over a sequence of Kullback-Leibler balls is time unit invariant. This is also the case for the entropic risk measure. On the other hand, multiperiod Value at Risk and multiperiod Expected Shortfall are not time unit invariant.

  7. Analysis of Serbian Military Riverine Units Capability for Participation in the United Nations Peacekeeping Operations

    Directory of Open Access Journals (Sweden)

    Slobodan Radojevic

    2017-06-01

    Full Text Available This paper analyses required personnel, training capacities and equipment for participation in the United Nations peacekeeping operations with the riverine elements. In order to meet necessary capabilities for engagement in United Nations peacekeeping operations, Serbian military riverine units have to be compatible with the issued UN requirements. Serbian Armed Forces have the potential to reach such requirements with the River Flotilla as a pivot for the participation in UN missions. Serbian Military Academy adopted and developed educational and training program in accordance with the provisions and recommendations of the IMO conventions and IMO model courses. Serbian Military Academy has opportunities for education and training military riverine units for participation in the United Nations peacekeeping operations. Moreover, Serbia has Multinational Operations Training Center and Peacekeeping Operations Center certified to provide selection, training, equipping and preparations of individuals and units to the United Nations multinational operations.

  8. Analysis of United States' Broadband Policy

    National Research Council Canada - National Science Library

    Uzarski, Joel S

    2007-01-01

    .... With every month that passes, the United States fails to close the gap in the digital divide both inside its borders as well as among the other countries that lead the world in broadband penetration...

  9. Mochovce Unit 3 and 4 Completion

    International Nuclear Information System (INIS)

    Aquilanti, G.

    2007-01-01

    Purpose of the Feasibility Study was to define in detail all technical, economic, financial, legal and authorization aspects of Mochovce NPP Unit 3 and 4 completion in order to provide Slovenske Elektrarne, a. s. (SE) and ENEL Top Management with all the necessary information for a final decision on Mochovce Unit 3 and 4. Feasibility study has started in January 2006. SE had the commitment to complete the Feasibility Study within 12 months from Closing of SE acquisition (April 2007). In order not to delay completion of Mochovce Unit 3 and 4, SE has decided to perform, in parallel to the Feasibility study, also all design and permitting activities which are required for the completion of Plant. This has involved anticipation of expenses for approximately 700 MSKK (or approx. 20 MEuro). SE was able to announce the positive decision about completion on Mochovce NPP Unit 3 and 4, two months in advance of the deadline.

  10. 77 FR 65459 - United Nations Day, 2012

    Science.gov (United States)

    2012-10-29

    ... when the global community acts collectively. Dedicated to assuring ``the equal rights of men and women... better part of a century, we have seen what is possible when a strong and united international community...

  11. 2012 United States Automatic Identification System Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2012 United States Automatic Identification System Database contains vessel traffic data for planning purposes within the U.S. coastal waters. The database is...

  12. 2014 United States Automatic Identification System Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2014 United States Automatic Identification System Database contains vessel traffic data for planning purposes within the U.S. coastal waters. The database is...

  13. Toll Facilities in the United States

    Data.gov (United States)

    Department of Transportation — Biennial report containing selected information on toll facilities in the United States that has been provided to FHWA by the States and/or various toll authorities...

  14. Health, United States, 2012: Men's Health

    Science.gov (United States)

    ... Mailing List Previous Reports Suggested Citation Related Sites Purchase Health, United States Behavioral Health Report Children’s ... with Internet Explorer may experience difficulties in directly accessing links to Excel files ...

  15. Improving the United States' Strategic Communication Strategy

    National Research Council Canada - National Science Library

    Risberg, Robert H

    2008-01-01

    ...? Much of the answer to this question is the failure of the United States Government to effectively use strategic communication to inform and influence populations to recognize the value of American...

  16. Shuttle Kit Freezer Refrigeration Unit Conceptual Design

    Science.gov (United States)

    Copeland, R. J.

    1975-01-01

    The refrigerated food/medical sample storage compartment as a kit to the space shuttle orbiter is examined. To maintain the -10 F in the freezer kit, an active refrigeration unit is required, and an air cooled Stirling Cycle refrigerator was selected. The freezer kit contains two subsystems, the refrigeration unit, and the storage volume. The freezer must provide two basic capabilities in one unit. One requirement is to store 215 lbs of food which is consumed in a 30-day period by 7 people. The other requirement is to store 128.3 lbs of medical samples consisting of both urine and feces. The unit can be mounted on the lower deck of the shuttle cabin, and will occupy four standard payload module compartments on the forward bulkhead. The freezer contains four storage compartments.

  17. RF accelerating unit installed in the PSB

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    RF accelerating unit installed in the PSB ring between two bending magnets. Cool air from a heat exchanger is injected into the four cavities from the central feeder and the hot air recirculated via the lateral ducts.

  18. United States Interagency Elevation Inventory (USIEI)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The U.S. Interagency Elevation Inventory displays high-accuracy topographic and bathymetric data for the United States and its territories. The project is a...

  19. 2009 United States Automatic Identification System Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2009 United States Automatic Identification System Database contains vessel traffic data for planning purposes within the U.S. coastal waters. The database is...

  20. NCHS - Leading Causes of Death: United States

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset presents the age-adjusted death rates for the 10 leading causes of death in the United States beginning in 1999. Data are based on information from all...

  1. United States Stateplane Zones - NAD27

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — U.S. State Plane Zones (NAD 1927) represents the State Plane Coordinate System (SPCS) Zones for the 1927 North American Datum within United States.

  2. Tax_Unit_Certification_Final_2012

    Data.gov (United States)

    Kansas Data Access and Support Center — The Statewide GIS Tax Unit boundary file was created through a collaborative partnership between the State of Kansas Department of Revenue Property Valuation...

  3. Tax_Units_Certification_2013_0301

    Data.gov (United States)

    Kansas Data Access and Support Center — The Statewide GIS Tax Unit boundary file was created through a collaborative partnership between the State of Kansas Department of Revenue Property Valuation...

  4. Unit Testing for Command and Control Systems

    Science.gov (United States)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  5. United States Stateplane Zones - NAD83

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — U.S. State Plane Zones (NAD 1983) represents the State Plane Coordinate System (SPCS) Zones for the 1983 North American Datum within United States.

  6. The United States and Europe: Current Issues

    National Research Council Canada - National Science Library

    Archick, Kristin; Morelli, Vince L

    2006-01-01

    The United States and Europe share a long and intertwined history. Both sides of the Atlantic face a common set of international concerns, have few other comparable partners, and share a deep economic relationship...

  7. Dengue Fever in the United States

    Centers for Disease Control (CDC) Podcasts

    Dr. Amesh Adalja, an associate at the Center for Biosecurity and clinical assistant professor at the University of Pittsburgh School, of Medicine, discusses dengue fever outbreaks in the United States.

  8. Climate change indicators in the United States

    Science.gov (United States)

    2010-04-01

    The U.S. Environmental Protection Agency (EPA) has published this report, Climate Change Indicators in the United States, to help readers interpret a set of important indicators to better understand climate change. The report presents 24 indicators, ...

  9. Implementation of an Integrated Neuroscience Unit.

    Science.gov (United States)

    Breslin, Rory P; Franker, Lauren; Sterchi, Suzanne; Sani, Sepehr

    2016-02-01

    Many challenges exist in today's health care delivery system, and much focus and research are invested into ways to improve care with cost-effective measures. Specialty-specific dedicated care units are one solution for inpatient hospital care because they improve outcomes and decrease mortality. The neuroscience population encompasses a wide variety of diagnoses of spinal to cranial issues with a wide spectrum of needs varying from one patient to the next. Neuroscience care must be patient-specific during the course of frequent acuity changes, and one way to achieve this is through a neuroscience-focused unit. Few resources are available on how to implement this type of unit. Advanced practice nurses are committed to providing high-quality, safe, and cost-effective care and are instrumental in the success of instituting a unit dedicated to the care of neuroscience patients.

  10. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  11. Death in the United States, 2011

    Science.gov (United States)

    ... Order from the National Technical Information Service NCHS Death in the United States, 2011 Recommend on Facebook ... 2011 SOURCE: National Vital Statistics System, Mortality. Do death rates vary by state? States experience different mortality ...

  12. Hanford Site Waste Management Units Report

    Energy Technology Data Exchange (ETDEWEB)

    Shearer, Jeffrey P. [Hanford Site (HNF), Richland, WA (United States)

    2012-02-29

    The Hanford Site Waste Management Units Report (HSWMUR) has been created to meet the requirements of the Tri-Party Agreement (TPA) Action Plan, Section 3.5, which states: “The Hanford Site Waste Management Units Report shall be generated, in a format agreed upon by the Parties, as a calendar year report and issued annually by the DOE by the end of February of each year, and posted electronically for regulator and public access. This report shall reflect all changes made in waste management unit status during the previous year.” This February 2012 version of the HSWMUR contains a comprehensive inventory of the 3389 sites and 540 subsites in the Waste Information Data System (WIDS). The information for each site contains a description of each unit and the waste it contains, where applicable. The WIDS database provides additional information concerning the sites contained in this report and is maintained with daily changes to these sites.

  13. Hanford Site Waste Management Units Report

    Energy Technology Data Exchange (ETDEWEB)

    Shearer, Jeffrey P. [Hanford Site (HNF), Richland, WA (United States)

    2013-02-13

    The Hanford Site Waste Management Units Report (HSWMUR) has been created to meet the requirements of the Tri-Party Agreement (TPA) Action Plan, Section 3.5, which states: “The Hanford Site Waste Management Units Report shall be generated, in a format agreed upon by the Parties, as a calendar year report and issued annually by the DOE by the end of February of each year, and posted electronically for regulator and public access. This report shall reflect all changes made in waste management unit status during the previous year.” This February 2013 version of the HSWMUR contains a comprehensive inventory of the 3427 sites and 564 subsites in the Waste Information Data System (WIDS). The information for each site contains a description of each unit and the waste it contains, where applicable. The WIDS database provides additional information concerning the sites contained in this report and is maintained with daily changes to these sites.

  14. Surveillance for Viral Hepatitis - United States, 2014

    Science.gov (United States)

    ... Resource Center Anonymous Feedback Viral Hepatitis Surveillance for Viral Hepatitis – United States, 2014 Recommend on Facebook Tweet Share ... Cases Hepatitis A Hepatitis B Hepatitis C Discussion Hepatitis A virus Index PAGE DESCRIPTION Table 2.1 Reported ...

  15. Hanford Site Waste Management Units Report

    Energy Technology Data Exchange (ETDEWEB)

    Shearer, Jeffrey P. [Hanford Site (HNF), Richland, WA (United States)

    2014-02-19

    The Hanford Site Waste Management Units Report (HSWMUR) has been created to meet the requirements of the Tri-Party Agreement (TPA) Action Plan, Section 3.5, which states: “The Hanford Site Waste Management Units Report shall be generated, in a format agreed upon by the Parties, as a calendar year report and issued annually by the DOE by the end of February of each year, and posted electronically for regulator and public access. This report shall reflect all changes made in waste management unit status during the previous year.” This February 2013 version of the HSWMUR contains a comprehensive inventory of the 3438 sites and 569 subsites in the Waste Information Data System (WIDS). The information for each site contains a description of each unit and the waste it contains, where applicable. The WIDS database provides additional information concerning the sites contained in this report and is maintained with daily changes to these sites.

  16. 2010 United States Automatic Identification System Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2010 United States Automatic Identification System Database contains vessel traffic data for planning purposes within the U.S. coastal waters. The database is...

  17. 2011 United States Automatic Identification System Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2011 United States Automatic Identification System Database contains vessel traffic data for planning purposes within the U.S. coastal waters. The database is...

  18. Functional Analysis of Kori Unit 1

    International Nuclear Information System (INIS)

    Choi, Seong Soo; Han, Jeong Hyun; Heo, Tae Young

    2009-07-01

    Function Analysis of Kori Unit 1 has been performed as a part of independent human factors review tasks for control room renovation of the plant. The top level goal defined for the scope of function analysis is 'Generate Electricity'. Through this function analysis of Kori Unit 1, the detailed sub-functions extracted from the existing design documents and procedures, functional relationships among the high level functions, functional classification of each hierarchical level, and tree diagrams of the hierarchical function structures of the plant were developed and identified as the result of the project. In addition, we investigated and compiled the specifications of MMIS devices used in Ulchin Nuclear Power Plant Unit 5,6 in accordance with the request from KAERI. The results of those researches will be used as basis data for independent review of the control room MMIS design of the Kori Unit 1

  19. Biomolecular Sciences: uniting Biology and Chemistry

    NARCIS (Netherlands)

    Vrieling, Engel

    2017-01-01

    Biomolecular Sciences: uniting Biology and Chemistry www.rug.nl/research/gbb The scientific discoveries in biomolecular sciences have benefitted enormously from technological innovations. At the Groningen Biomolecular Science and Biotechnology Institute (GBB) we now sequence a genome in days,

  20. Environmental Measurements Laboratory 2002 Unit Performance Plan

    Energy Technology Data Exchange (ETDEWEB)

    None

    2001-10-01

    This EML Unit Performance Plan provides the key goals and performance measures for FY 2002 and continuing to FY 2003. The purpose of the Plan is to inform EML's stakeholders and customers of the Laboratory's products and services, and its accomplishments and future challenges. Also incorporated in the Unit Performance Plan is EML's Communication Plan for FY 2002.

  1. Indoor unit for electric heat pump

    Science.gov (United States)

    Draper, R.; Lackey, R.S.; Fagan, T.J. Jr.; Veyo, S.E.; Humphrey, J.R.

    1984-05-22

    An indoor unit for an electric heat pump is provided in modular form including a refrigeration module, an air mover module, and a resistance heat package module, the refrigeration module including all of the indoor refrigerant circuit components including the compressor in a space adjacent the heat exchanger, the modules being adapted to be connected to air flow communication in several different ways as shown to accommodate placement of the unit in various orientations. 9 figs.

  2. BN-1200 Reactor Power Unit Design Development

    International Nuclear Information System (INIS)

    Vasilyev, B.A.; Shepelev, S.F.; Ashirmetov, M.R.; Poplavsky, V.M.

    2013-01-01

    Main goals of BN-1200 design: • Develop a reliable new generation reactor plant for the commercial power unit with fast reactor to implement the first-priority objectives in changing over to closed nuclear fuel cycle; • Improve technical and economic indices of BN reactor power unit to the level of those of Russian VVER of equal power; • Enhance the safety up to the level of the requirements for the 4th generation RP

  3. Leadership Stability in Army Reserve Component Units

    Science.gov (United States)

    2013-01-01

    OMB control number. 1. REPORT DATE 2013 2. REPORT TYPE 3. DATES COVERED 00-00-2013 to 00-00-2013 4. TITLE AND SUBTITLE Leadership Stability in...standards for research quality and objectivity. Leadership Stability in Army Reserve Component Units Thomas F. Lippiatt, J. Michael Polich NATIONAL SECURITY...RESEARCH DIVISION Leadership Stability in Army Reserve Component Units Thomas F. Lippiatt, J. Michael Polich Prepared for the Office of the

  4. Detection unit with corrected energy dependence

    International Nuclear Information System (INIS)

    Viererbl, L.

    1989-01-01

    The detection unit consists of a plastic scintillator with a layer of a powder semicrystalline scintillator deposited on its surface. An inorgaic monocrystalline scintillator is placed inside the plastic scintillator and surrounded with an absorption layer, except for the window. The advantage of the detection unit is a reduced energy dependence of response, especially in the energy range 100 to 400 keV. (E.J.). 3 figs

  5. New steam generators slated for nuclear units

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This article is a brief discussion of Duke Power's plans to replace steam generators at its McGuire and Catawba nuclear units. A letter of intent to purchase (from Babcock and Wilcox) the 12 Westinghouse steam generators has been signed, but no constructor has been selected at this time. This action is brought about by the failures of more than 3000 tubes in these units

  6. 'So Unit One has been shut down!'

    International Nuclear Information System (INIS)

    Tomek, J.

    2007-01-01

    The Slovak Government decided to shut down both units of V-1 NPP by its resolution No. 801 as early as in September 1999, when SE was 100% owned by the State, or the National Property Fund. Even though SE has recently tried to postpone the decommissioning date, it did not find understanding from the European Union, because this obligation of the Government is part of the Accession Treaty. Unit shut down started at noon in the last day of 2006. (author)

  7. NASA work unit system file maintenance manual

    Science.gov (United States)

    1972-01-01

    The NASA Work Unit System is a management information system for research tasks (i.e., work units) performed under NASA grants and contracts. It supplies profiles on research efforts and statistics on fund distribution. The file maintenance operator can add, delete and change records at a remote terminal or can submit punched cards to the computer room for batch update. The system is designed for file maintenance by a person with little or no knowledge of data processing techniques.

  8. Fragmentation of Continental United States Forests

    Science.gov (United States)

    Kurt H. Riitters; James D. Wickham; Robert V. O' Neill; K. Bruce Jones; Elizabeth R. Smith; John W. Coulston; Timothy G. Wade; Jonathan H. Smith

    2002-01-01

    We report a multiple-scale analysis of forest fragmentation based on 30-m (0.09 ha pixel-1) land- cover maps for the conterminous United States. Each 0.09-ha unit of forest was classified according to fragmentation indexes measured within the surrounding landscape, for five landscape sizes including 2.25, 7.29, 65.61, 590.49, and 5314.41 ha....

  9. Non-linear Loudspeaker Unit Modelling

    DEFF Research Database (Denmark)

    Pedersen, Bo Rohde; Agerkvist, Finn T.

    2008-01-01

    Simulations of a 6½-inch loudspeaker unit are performed and compared with a displacement measurement. The non-linear loudspeaker model is based on the major nonlinear functions and expanded with time-varying suspension behaviour and flux modulation. The results are presented with FFT plots of thr...... frequencies and different displacement levels. The model errors are discussed and analysed including a test with loudspeaker unit where the diaphragm is removed....

  10. Power Efficient Division and Square Root Unit

    DEFF Research Database (Denmark)

    Liu, Wei; Nannarelli, Alberto

    2012-01-01

    Although division and square root are not frequent operations, most processors implement them in hardware to not compromise the overall performance. Two classes of algorithms implement division or square root: digit-recurrence and multiplicative (e.g., Newton-Raphson) algorithms. Previous work....... The proposed unit is compared to similar solutions based on the digit-recurrence algorithm and it is compared to a unit based on the multiplicative Newton-Raphson algorithm....

  11. Internationalization path to the United Arab Emirates

    OpenAIRE

    Räsänen, Paula

    2010-01-01

    The purpose of the thesis was to introduce internationalization of an SME including motives and risks of new market entry, as well as describing the steps of a target market selection and presenting different operational modes. Since the executive company, DesignShopOutlet, was interested in exploring their market possibilities in the United Arab Emirates, the aim of the thesis was also to conduct a market research report of the United Arab Emirates. The study applied a qualitative resea...

  12. Energy problems of the United States

    International Nuclear Information System (INIS)

    Pertuzio, A.

    2006-01-01

    The united states are the third world producer of oil which accounts for 440% of world production and 20 million barrels/day of which 60% are imported. That dependence on imports is likely to increase in the next decades. Such supplies and their security are therefore a fundamental factor of the United States foreign policy in combination with their political, economic and strategic objectives in a world both unsure and dangerous

  13. Trial by jury in the United States

    Directory of Open Access Journals (Sweden)

    Lochhead Robert

    2015-10-01

    Full Text Available Th e Republic of Moldova is considering the adoption of trial by jury in select criminal cases. Th e following article is intended to contribute to the discussion of that proposal. Th e article will briefl y describe the history of juries under the English common law and as adopted by the United States. It will then outline some of the basic procedures in trials by jury as currently practiced in the United States federal court system.

  14. Actinide partitioning-transmutation program. V. Preconceptual designs and costs of partitioning facilities and shipping casks, Appendix 4. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    This Appendix contains cost estimate documents for the Fuels Fabrication Plant Waste Treatment Facility. Plant costs are summarized by Code of Accounts and by Process Function. Costs contributing to each account are detailed. Process equipment costs are detailed for each Waste Treatment Process. Service utility costs are also summarized and detailed. Shipping cask costs are provided.

  15. AGR-3/4 Final Data Qualification Report for ATR Cycles 151A through 155B-1

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Binh T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-03-01

    This report provides the qualification status of experimental data for the entire Advanced Gas Reactor 3/4 (AGR 3/4) fuel irradiation. AGR-3/4 is the third in a series of planned irradiation experiments conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for the AGR Fuel Development and Qualification Program, which supports development of the advanced reactor technology under the INL ART Technology Development Office (TDO). The main objective of AGR-3/4 irradiation is to provide a known source of fission products for subsequent transport through compact matrix and structural graphite materials due to the presence of designed-to-fail fuel particles. Full power irradiation of the AGR 3/4 test began on December 14, 2011 (ATR Cycle 151A), and was completed on April 12, 2014 (end of ATR Cycle 155B) after 369.1 effective full power days of irradiation. The AGR-3/4 test was in the reactor core for eight of the ten ATR cycles between 151A and 155B. During the unplanned outage cycle, 153A, the experiment was removed from the ATR northeast flux trap (NEFT) location and stored in the ATR canal. This was to prevent overheating of fuel compacts due to higher than normal ATR power during the subsequent Powered Axial Locator Mechanism cycle, 153B. The AGR 3/4 test was inserted back into the ATR NEFT location during the outage of ATR Cycle 154A on April 26, 2013. Therefore, the AGR-3/4 irradiation data received during these 2 cycles (153A and 153B) are irrelevant and their qualification status isnot included in this report. Additionally, during ATR Cycle 152A the ATR core ran at low power for a short enough duration that the irradiation data are not used for physics and thermal calculations. However, the qualification status of irradiation data for this cycle is still covered in this report. As a result, this report includes data from 8 ATR Cycles: 151A, 151B, 152A, 152B, 154A, 154B, 155A, and 155B, as recorded in the Nuclear Data Management and Analysis System (NDMAS). The AGR 3/4 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates, pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates, release to birth rate ratios [R/Bs], and particle failure counts) for each of the twelve capsules in the AGR 3/4 experiment. During Outage Cycle 155A, fourteen flow meters were installed downstream from fourteen FPMS monitors to measure flows from the monitors; qualification status of these data are also included in the report. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) composed of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. For ATR Cycles 151A through 154B, the DRC convened on February 12, 2014, reviewed the data acquisition process, and considered whether the data met the requirements for data collection as specified in QA approved INL ART TDO data collection plans. The DRC also examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report. The qualification status of AGR-3/4 irradiation data during the first six cycles were previously reported in INL/EXT-14-31186 document. This report presents data qualification status for the entire AGR-3/4 irradiation.

  16. Simulation of heat-pump systems in Polysun 4 - Final report; Simulation von Waermepumpen-Systemen in Polysun 4 - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Marti, J.; Witzig, A. [Vela Solaris AG, Winterthur (Switzerland); Huber, A.; Ochs, M. [Huber Energietechnik AG, Zuerich (Switzerland)

    2009-01-15

    Polysun 4 is a software program for the simulation of heating systems. The simulation kernel applies a time stepping algorithm and dynamically calculates all relevant system parameters over a one year period, based on statistical weather data. On the one hand, Polysun draws out by physics-based simulation scheme and its modularity, which allows any arrangement of the system components. On the other hand, Polysun offers a unique set of component catalogues which cover a large number of commercially available system components. In this project, three kinds of heat pumps have been integrated in Polysun, namely the air/water, water/water and brine/water heat pumps. Furthermore, the relevant heat sources have been implemented, namely ambient air, soil and groundwater. In consequence, Polysun now covers a large, and almost complete, range of renewable energy systems. Simulation parameters are the measured heat pump COP values (in accordance with EN 255 and EN 14511). A linear interpolation scheme has been developed in this project in order to simulate systems for arbitrary source and heat pump temperatures and to interpolate the power consumption. For the dynamic simulation of the ground source heat pump, the numerical algorithm from the Program EWS (calculation module developed in 1997) has been integrated into Polysun. Groundwater probes are calculated with respect to the soil temperatures. Heat pumps and probes were implemented as independent components in Polysun. In the graphical user interface, they can be arbitrarily placed and connected with other hydraulic components. The timestepping simulation calculates inlet temperature, electric power consumption and heat transfer in the entire system. The Polysun catalogs have been extended accordingly with total over 300 component entries and a number of relevant system templates. (authors)

  17. Screening of candidate corrosion resistant materials for coal combustion environments -- Volume 4. Final report, January 31, 1997

    Energy Technology Data Exchange (ETDEWEB)

    Boss, D.E.

    1997-12-31

    The development of a silicon carbide heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structural materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal-shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. The candidate protective materials identified in a previous effort were screened for their stability to the EFCC combustion environment. Bulk samples of each of the eleven candidate materials were prepared, and exposed to coal slag for 100 hours at 1,370 C under flowing air. After exposure the samples were mounted, polished, and examined via x-ray diffraction, energy dispersive spectroscopy, and scanning electron microscopy. In general, the alumina-based materials behaved well, with comparable corrosion depths in all five samples. Magnesium chromite formed a series of reaction products with the slag, which included an alumina-rich region. These reaction products may act as a diffusion barrier to slow further reaction between the magnesium chromite and the slag and prove to be a protective coating. As for the other materials; calcium titanate failed catastrophically, the CS-50 exhibited extension microstructural and compositional changes, and zirconium titanate, barium zironate, and yttrium chromite all showed evidence of dissolution with the slag.

  18. Actinide partitioning-transmutation program. V. Preconceptual designs and costs of partitioning facilities and shipping casks, Appendix 4. Final report

    International Nuclear Information System (INIS)

    1980-06-01

    This Appendix contains cost estimate documents for the Fuels Fabrication Plant Waste Treatment Facility. Plant costs are summarized by Code of Accounts and by Process Function. Costs contributing to each account are detailed. Process equipment costs are detailed for each Waste Treatment Process. Service utility costs are also summarized and detailed. Shipping cask costs are provided

  19. Expanding the usefulness of unit supply cost

    International Nuclear Information System (INIS)

    McKenzie, M.B.; Petr, K.

    1992-01-01

    Unit supply cost is a widely used tool in the energy business for providing a one number-unit cost description. For example, controllable costs such as finding costs, development costs and operating costs have traditionally been described in an average cost per unit of reserves format for the oil and gas industry, however using this approach on more specific applications is not always informative. Projects with widely varying controllable parameters can still yield the same unit cost, making comparisons difficult. The application of unit supply cost can be readily expanded by adding a new unit cost component termed cost of capital. This element introduces the impacts of timing and return on investment into the supply cost determination through discounting annual costs. The cost of capital component adds the ability to represent a project's unique characteristics, particularly reserves' depletion rate and the timing or phasing of development. Introducing the cost of capital element into the supply cost analysis provides additional information and improves the likelihood of drawing correct conclusions when comparing and ranking projects. 4 figs., 6 tabs

  20. Regulatory audit to the Argentine teletherapy units

    International Nuclear Information System (INIS)

    Kay, J.M.

    1995-01-01

    As a consequence of an erroneous calibration of the ionization chamber dosimeter of a new licensed 6 Mev electron lineal accelerator that caused accidental overexposures in the first patients under treatment, the Regulatory Board decided to perform an audit to every teletherapy unit (accelerator and telegammatherapy units) in Argentina. The audit was carried out at the en of 1994 in 27 accelerators and 107 telegammatherapy units. The objectives of the audit were the control of the mechanical and optical aspects of the each accelerator and telegammatherapy unit and the control of the calibration of their radiation beams. The last action was undertaken to detect as soon as possible, any eventual accidental overexposure or underexposure of patients under treatment. The audit was conducted by the author and performed for a team of 22 inspectors who worked in groups of 2 to 3 people and completed the inspection of the teletherapy units of the whole country in 3 months. As a result of the audit, the Regulatory Board had in a short period a clear panorama of the performance of each teletherapy unit of the country and also confirmed that no accidental situation had happened. The audit revealed the necessity of imposing urgent regulatory requirements not related to the calibration of the radiation beam in 5% of the cases, as well as non-urgent requirements of different importance in approximately other 60% of the cases. (author)

  1. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jang, Seung-cheol [KAERI, Daejeon (Korea, Republic of); Heo, Gyunyoung [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future.

  2. Case Study of Multi-Unit Risk: Multi-Unit Station Black-Out

    International Nuclear Information System (INIS)

    Oh, Kyemin; Jang, Seung-cheol; Heo, Gyunyoung

    2015-01-01

    After Fukushima Daiichi Accident, importance and public concern for Multi-Unit Risk (MUR) or Probabilistic Safety Assessment (PSA) have been increased. Most of nuclear power plant sites in the world have more than two units. These sites have been facing the problems of MUR or accident such as Fukushima. In case of South Korea, there are generally more than four units on the same site and even more than ten units are also expected. In other words, sites in South Korea also have been facing same problems. Considering number of units on the same site, potential of these problems may be larger than other countries. The purpose of this paper is to perform case study based on another paper submitted in the conference. MUR is depended on various site features such as design, shared systems/structures, layout, environmental condition, and so on. Considering various dependencies, we assessed Multi-Unit Station Black-out (MSBO) accident based on Hanul Unit 3 and 4 model. In this paper, case study for multi-unit risk or PSA had been performed. Our result was incomplete to assess total multi-unit risk because of two challenging issues. First, economic impact had not been evaluated to estimate multi-unit risk. Second, large uncertainties were included in our result because of various assumptions. These issues must be resolved in the future

  3. International boundary experiences by the United Nations

    Science.gov (United States)

    Kagawa, A.

    2013-12-01

    Over the last few decades, the United Nations (UN) has been approached by Security Council and Member States on international boundary issues. The United Nations regards the adequate delimitation and demarcation of international boundaries as a very important element for the maintenance of peace and security in fragile post-conflict situations, establishment of friendly relationships and cross-border cooperation between States. This paper will present the main principles and framework the United Nations applies to support the process of international boundary delimitation and demarcation activities. The United Nations is involved in international boundary issues following the principle of impartiality and neutrality and its role as mediator. Since international boundary issues are multi-faceted, a range of expertise is required and the United Nations Secretariat is in a good position to provide diverse expertise within the multiple departments. Expertise in different departments ranging from legal, political, technical, administrative and logistical are mobilised in different ways to provide support to Member States depending on their specific needs. This presentation aims to highlight some of the international boundary projects that the United Nations Cartographic Section has been involved in order to provide the technical support to different boundary requirements as each international boundary issue requires specific focus and attention whether it be in preparation, delimitation, demarcation or management. Increasingly, the United Nations is leveraging geospatial technology to facilitate boundary delimitation and demarcation process between Member States. Through the presentation of the various case studies ranging from Iraq - Kuwait, Israel - Lebanon (Blue Line), Eritrea - Ethiopia, Cyprus (Green Line), Cameroon - Nigeria, Sudan - South Sudan, it will illustrate how geospatial technology is increasingly used to carry out the support. In having applied a range

  4. 28 CFR 541.47 - Admission to control unit.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Admission to control unit. 541.47 Section... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.47 Admission to control unit. Staff shall provide an inmate admitted to a control unit with: (a) Notice of the projected duration of...

  5. 28 CFR 541.50 - Release from a control unit.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Release from a control unit. 541.50... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.50 Release from a control unit. (a) Only the Executive Panel may release an inmate from a control unit. The following factors are...

  6. 28 CFR 541.48 - Search of control unit inmates.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Search of control unit inmates. 541.48... INMATE DISCIPLINE AND SPECIAL HOUSING UNITS Control Unit Programs § 541.48 Search of control unit inmates. (a) The Warden at an institution housing a control unit may order a digital or simple instrument...

  7. Meteorite Unit Models for Structural Properties

    Science.gov (United States)

    Agrawal, Parul; Carlozzi, Alexander A.; Karajeh, Zaid S.; Bryson, Kathryn L.

    2017-10-01

    To assess the threat posed by an asteroid entering Earth’s atmosphere, one must predict if, when, and how it fragments during entry. A comprehensive understanding of the asteroid material properties is needed to achieve this objective. At present, the meteorite material found on earth are the only objects from an entering asteroid that can be used as representative material and be tested inside a laboratory. Due to complex composition, it is challenging and expensive to obtain reliable material properties by means of laboratory test for a family of meteorites. In order to circumvent this challenge, meteorite unit models are developed to determine the effective material properties including Young’s modulus, compressive and tensile strengths and Poisson’s ratio, that in turn would help deduce the properties of asteroids. The meteorite unit model is a representative volume that accounts for diverse minerals, porosity, cracks and matrix composition.The Young’s Modulus and Poisson’s Ratio in the meteorite units are calculated by performing several hundreds of Monte Carlo simulations by randomly distributing the various phases inside these units. Once these values are obtained, cracks are introduced in these units. The size, orientation and distribution of cracks are derived by CT-scans and visual scans of various meteorites. Subsequently, simulations are performed to attain stress-strain relations, strength and effective modulus values in the presence of these cracks. The meteorite unit models are presented for H, L and LL ordinary chondrites, as well as for terrestrial basalt. In the case of the latter, data from the simulations is compared with experimental data to validate the methodology. These meteorite unit models will be subsequently used in fragmentation modeling of full scale asteroids.

  8. Principles of applying Poisson units in radiology

    International Nuclear Information System (INIS)

    Benyumovich, M.S.

    2000-01-01

    The probability that radioactive particles hit particular space patterns (e.g. cells in the squares of a count chamber net) and time intervals (e.g. radioactive particles hit a given area per time unit) follows the Poisson distribution. The mean is the only parameter from which all this distribution depends. A metrological base of counting the cells and radioactive particles is a property of the Poisson distribution assuming equality of a standard deviation to a root square of mean (property 1). The application of Poisson units in counting of blood formed elements and cultured cells was proposed by us (Russian Federation Patent No. 2126230). Poisson units relate to the means which make the property 1 valid. In a case of cells counting, the square of these units is equal to 1/10 of one of count chamber net where they count the cells. Thus one finds the means from the single cell count rate divided by 10. Finding the Poisson units when counting the radioactive particles should assume determination of a number of these particles sufficient to make equality 1 valid. To this end one should subdivide a time interval used in counting a single particle count rate into different number of equal portions (count numbers). Next one should pick out the count number ensuring the satisfaction of equality 1. Such a portion is taken as a Poisson unit in the radioactive particles count. If the flux of particles is controllable one should set up a count rate sufficient to make equality 1 valid. Operations with means obtained by with the use of Poisson units are performed on the base of approximation of the Poisson distribution by a normal one. (author)

  9. Challenges encountered by critical care unit managers in the large intensive care units.

    Science.gov (United States)

    Matlakala, Mokgadi C; Bezuidenhout, Martie C; Botha, Annali D H

    2014-04-04

    Nurses in intensive care units (ICUs) are exposed regularly to huge demands interms of fulfilling the many roles that are placed upon them. Unit managers, in particular, are responsible for the efficient management of the units and have the responsibilities of planning, organising, leading and controlling the daily activities in order to facilitate the achievement of the unit objectives. The objective of this study was to explore and present the challenges encountered by ICU managers in the management of large ICUs. A qualitative, exploratory and descriptive study was conducted at five hospital ICUs in Gauteng province, South Africa. Data were collected through individual interviews from purposively-selected critical care unit managers, then analysed using the matic coding. Five themes emerged from the data: challenges related to the layout and structure of the unit, human resources provision and staffing, provision of material resources, stressors in the unit and visitors in the ICU. Unit managers in large ICUs face multifaceted challenges which include the demand for efficient and sufficient specialised nurses; lack of or inadequate equipment that goes along with technology in ICU and supplies; and stressors in the ICU that limit the efficiency to plan, organise, lead and control the daily activities in the unit. The challenges identified call for multiple strategies to assist in the efficient management of large ICUs.

  10. Challenges encountered by critical care unit managers in the large intensive care units

    Directory of Open Access Journals (Sweden)

    Mokgadi C. Matlakala

    2014-04-01

    Full Text Available Background: Nurses in intensive care units (ICUs are exposed regularly to huge demands interms of fulfilling the many roles that are placed upon them. Unit managers, in particular, are responsible for the efficient management of the units and have the responsibilities of planning, organising, leading and controlling the daily activities in order to facilitate the achievement of the unit objectives. Objectives: The objective of this study was to explore and present the challenges encountered by ICU managers in the management of large ICUs. Method: A qualitative, exploratory and descriptive study was conducted at five hospital ICUs in Gauteng province, South Africa. Data were collected through individual interviews from purposively-selected critical care unit managers, then analysed using the matic coding. Results: Five themes emerged from the data: challenges related to the layout and structure of the unit, human resources provision and staffing, provision of material resources, stressors in the unit and visitors in the ICU. Conclusion: Unit managers in large ICUs face multifaceted challenges which include the demand for efficient and sufficient specialised nurses; lack of or inadequate equipment that goes along with technology in ICU and supplies; and stressors in the ICU that limit the efficiency to plan, organise, lead and control the daily activities in the unit. The challenges identified call for multiple strategies to assist in the efficient management of large ICUs.

  11. LMFBR steam generators in the United Kingdom

    International Nuclear Information System (INIS)

    Anderson, R.; Hayden, O.

    2002-01-01

    Experience has been gained in the UK on the operation of LMFBR Steam Generator Units (SGU) over a period of 20 years from the Dounreay Fast Reactor (DFR) and the Prototype Fast Reactor (PFR). The DFR steam generator featured a double barrier and therefore did not represent a commercial design. PFR, however, faced the challenge of a single wall design and it is experience from this which is most valuable. The PFR reactor went critical in March 1974 and the plant operating history since then has been dominated by experience with leaks in the tube to tube plate welds of the high performance U-tubes SGU's. Operation at high power using the full complement of three secondary sodium circuits was delayed until July 1976 by the occurrence of leaks in the tube to tube plate welds of the superheater and reheater units which are fabricated in stainless steel. Repairs were carried out to the two superheaters and they were returned to service. The reheater tube bundle was removed from circuit after sodium was found to have entered the steam side. When the sodium had been removed and inspection carried out it was decided not to recover the unit. Since 1976 the remaining five stainless steel units have operated satisfactorily. This year a replacement reheater unit has been installed. This is of a new design in 9-Cr-Mo ferritic steel using a sleeve through which the steam tube passes to eliminate the tube to tube plate weld. Despite a few early leaks in evaporator tube to tube plate welds up to 1979, these failures did not initially present a major problem. However, in 1980 the rate of evaporator weld failures increased and despite the successful application of a shot peening process to eliminate stress corrosion failures from the water side of the weld, failures traced to the sodium side continued. A sleeving process was developed for application to complete evaporator units on a production basis with the objective of bypassing the welds at each end of the 500 tubes. The decision

  12. Racial Conflict in the United States: What Should Be Done? Grade Twelve. [Resource Unit V.] Project Social Studies.

    Science.gov (United States)

    Minnesota Univ., Minneapolis. Project Social Studies Curriculum Center.

    This is the fifth of seven resource units for a twelfth grade course on value conflicts and policy decisions. The topic for this unit is racial conflict in the United States. The introduction explains how this unit coincides with other units of the K-12 series which have treated intergroup relations. The objectives are listed as to…

  13. Low resource ventilation unit; Ressourcebesparende ventilationsenhed

    Energy Technology Data Exchange (ETDEWEB)

    Drivsholm, C.

    2012-03-15

    In the project a resource-saving ventilation device was developed which is based on the use of a regenerator and a reversible air flow. The regenerator is placed in the building envelope, and the concept works in the way that the heat in the air during ventilation is stored in the regenerator and brought back into the building by a reversible air change. The heated air is blown from inside the building out through the regenerator. In this way the regenerator accumulates the heat in the air. Over a period of 30-120 seconds, the regenerator capacity is utilized. When the regenerator cannot be further heated, the air flow is reversed and there is now blown cold air through the regenerator. Thereby the heat from the regenerator is released to the cold fresh air. Thus, the fresh air brings heat back into the building, whereby the air is replaced with a limited heat loss. Ventilation with a regenerator is described as micro-ventilation. The developed micro-ventilation unit was tested by the Danish Technological Institute. The test results shows that the unit performs according to expectations: 1) The heat recovery is 85%; 2) The flow through the unit is 80m3 per hour in a 5 section unit; 3) The noise level is 30 db(A) in a representative room; 4) The energy consumption is <300 J/m3. The unit is introduced into the market, and the first plants have been sold. (LN)

  14. Automatic control unit for neutron transmission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Adib, M.; Abdel-Kawy, A.; Eid, Y.; Ashry, A.; Mostafa, M.; Hamouda, I. (Atomic Energy Establishment, Inshas (Egypt). Reactor and Neutron Physics Dept.)

    1981-01-01

    An automatic transistorized unit has been designed to control the neutron transmission measurements carried out using the time-of-flight spectrometer. The function of the automatic unit is to control the measurements of the neutron counting rate distribution transmitted through a sample at a selected channel group of the time analyzer for a certain preadjusted time period. At the end of this time, the unit removes the sample out of the neutron beam, selects a second equal channel group of the time analyzer and provides the measurement of the neutron counting rate distribution for the same time period as in the case with the sample on. Such a measuring cycle can be repeated as much as the experiment requires. At the end of these cycles the stored information can be immediately obtained through the analyzer read out unit. It is found that the time of removing the sample out of the neutron beam or returning it back does not exceed 20 seconds instead of the five minutes required in case of manual operation. The most important advantages of using such an automatic unit are saving about 20 percent of the reactor operating time avoidng unnecessary radiation exposure of the experimentalists.

  15. Nuclear power in the United States

    International Nuclear Information System (INIS)

    Johnston, J.B.

    1985-01-01

    All over the world except in the United States, nuclear energy is a low cost, secure, environmentally acceptable form of energy. In the United States, civilian nuclear power is dead. 112 nuclear power plants have been abandoned or cancelled in the last decade, and there has been no new order for nuclear plants since 1978. It will be fortunate to have 125 operating nuclear plants in the United States in the year 2000. There are almost 90 completed nuclear power plants and about 45 under construction in the United States, but several of those under construction will eventually be abandoned. About 20 % of the electricity in the United States will be generated by nuclear plants in 2000 as compared with 13 % supplied in the last year. Under the present regulatory and institutional arrangement, American electric utilities would not consider to order a new nuclear power plant. Post-TMI nuclear plants became very expensive, and there is also ideological opposition to nuclear power. Coal-firing plants are also in the similar situation. The uncertainty about electric power demand, the cost of money, the inflation of construction cost and regulation caused the situation. (Kako, I.)

  16. Antenna unit and radio base station therewith

    Science.gov (United States)

    Kuwahara, Mikio; Doi, Nobukazu; Suzuki, Toshiro; Ishida, Yuji; Inoue, Takashi; Niida, Sumaru

    2007-04-10

    Phase and amplitude deviations, which are generated, for example, by cables connecting an array antenna of a CDMA base station and the base station, are calibrated in the baseband. The base station comprises: an antenna apparatus 1; couplers 2; an RF unit 3 that converts a receive signal to a baseband signal, converts a transmit signal to a radio frequency, and performs power control; an A/D converter 4 for converting a receive signal to a digital signal; a receive beam form unit 6 that multiplies the receive signal by semi-fixed weight; a despreader 7 for this signal input; a time-space demodulator 8 for demodulating user data; a despreader 9 for probe signal; a space modulator 14 for user data; a spreader 13 for user signal; a channel combiner 12; a Tx calibrater 11 for controlling calibration of a signal; a D/A converter 10; a unit 16 for calculation of correlation matrix for generating a probe signal used for controlling an Rx calibration system and a TX calibration system; a spreader 17 for probe signal; a power control unit 18; a D/A converter 19; an RF unit 20 for probe signal; an A/D converter 21 for signal from the couplers 2; and a despreader 22.

  17. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  18. Psychogeriatric inpatient unit design: a literature review.

    Science.gov (United States)

    Dobrohotoff, John T; Llewellyn-Jones, Robert H

    2011-03-01

    In many parts of the world the provision of psychogeriatric inpatient units (PGUs) remains limited. More units will be required over coming decades given rapid population aging. Medline (1950-2010), psycINFO (1806-2009), EMBASE (1980-2009) and CINAHL (1982-2009) were searched for papers about PGU design. Selected non-peer reviewed literature such as government reports and unpublished academic dissertations were also reviewed. Data were also obtained from the literature related to general adult psychiatry inpatient units where there was limited information from studies of units designed for older people. Over 200 papers were reviewed and 130 were included. There are few good quality studies to guide the design of acute PGUs and much of the existing literature is based on opinion and anecdote or, at best, based on observational studies. Randomized controlled studies comparing different designs and assessing outcomes are virtually non-existent. Several studies have identified violence and trauma resulting from hospitalization as significant problems with current acute PGU care. Despite its limitations the available literature provides useful guidance on how PGU design can optimize patient and staff safety and improve clinical outcomes. There are significant problems with current acute PGUs, and patient mix on existing units is an important issue. Future research should examine patient and staff perceptions of different PGU ward environments, the relationship between ward design and clinical outcomes, the effects of segregating patients with challenging behaviors in dementia and the benefits or otherwise of gender segregation.

  19. 21 CFR 876.4300 - Endoscopic electrosurgical unit and accessories.

    Science.gov (United States)

    2010-04-01

    ... Endoscopic electrosurgical unit and accessories. (a) Identification. An endoscopic electrosurgical unit and... device includes the electrosurgical generator, patient plate, electric biopsy forceps, electrode, flexible snare, electrosurgical alarm system, electrosurgical power supply unit, electrical clamp, self...

  20. 31 CFR 596.313 - United States person.

    Science.gov (United States)

    2010-07-01

    ... FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TERRORISM LIST GOVERNMENTS SANCTIONS REGULATIONS General Definitions § 596.313 United States person. The term United States person means any United States...

  1. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  2. Snapshot analysis for rhodium fixed incore detector using BEACON methodology

    International Nuclear Information System (INIS)

    Cha, Kyoon Ho; Choi, Yu Sun; Lee, Eun Ki; Park, Moon Ghu; Morita, Toshio; Heibel, Michael D.

    2004-01-01

    The purpose of this report is to process the rhodium detector data of the Yonggwang nuclear unit 4 cycle 5 core for the measured power distribution by using the BEACON methodology. Rhodium snapshots of the YGN 4 cycle 5 have been analyzed by both BEACON/SPINOVA and CECOR to compare the results of both codes. By analyzing a large number of snapshots obtained during normal plant operation. Reviewing the results of this analysis, the BEACON/SPNOVA can be used for the snapshot analysis of Korean Standard Nuclear Power (KSNP) plants

  3. Axial power distribution calculation using a neural network in the nuclear reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Cha, K. H.; Lee, S. H. [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    This paper is concerned with an algorithm based on neural networks to calculate the axial power distribution using excore detector signals in the nuclear reactor core. The fundamental basis of the algorithm is that the detector response can be fairly accurately estimated using computational codes. In other words, the training set, which represents relationship between detector signals and axial power distributions, for the neural network can be obtained through calculations instead of measurements. Application of the new method to the Yonggwang nuclear power plant unit 3 (YGN-3) shows that it is superior to the current algorithm in place. 7 refs., 4 figs. (Author)

  4. Investigations on the optimum design of chemical addition system for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Byong Hoon [Junior College of Inchon, Inchon (Korea, Republic of); Chung, Chang Kyu; Choi, Han Rim; Kim, Eun Kee; Ro, Tae Sun [Korea Power Engineering Company, Inc. Taejon (Korea, Republic of)

    1997-12-31

    Mixing characteristics of the chemical additives in the chemical injection tank of the chemical and volume control system(CVCS) were investigated for the Yonggwang Nuclear units 5 and 6. Numerical calculations were performed with a low-Reynolds number turbulence model. Studies were also conducted for the injection tank with a disk located at 1/4H, 2/4H, and 3/4H from the inlet in order to see the effect in the enhancement of chemical mixing. Results show that the optimum arrangement is to locate a disk close to the inlet. 10 refs., 4 figs. (Author)

  5. Axial power distribution calculation using a neural network in the nuclear reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y H; Cha, K H; Lee, S H [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    This paper is concerned with an algorithm based on neural networks to calculate the axial power distribution using excore detector signals in the nuclear reactor core. The fundamental basis of the algorithm is that the detector response can be fairly accurately estimated using computational codes. In other words, the training set, which represents relationship between detector signals and axial power distributions, for the neural network can be obtained through calculations instead of measurements. Application of the new method to the Yonggwang nuclear power plant unit 3 (YGN-3) shows that it is superior to the current algorithm in place. 7 refs., 4 figs. (Author)

  6. Investigations on the optimum design of chemical addition system for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Byong Hoon [Junior College of Inchon, Inchon (Korea, Republic of); Chung, Chang Kyu; Choi, Han Rim; Kim, Eun Kee; Ro, Tae Sun [Korea Power Engineering Company, Inc. Taejon (Korea, Republic of)

    1998-12-31

    Mixing characteristics of the chemical additives in the chemical injection tank of the chemical and volume control system(CVCS) were investigated for the Yonggwang Nuclear units 5 and 6. Numerical calculations were performed with a low-Reynolds number turbulence model. Studies were also conducted for the injection tank with a disk located at 1/4H, 2/4H, and 3/4H from the inlet in order to see the effect in the enhancement of chemical mixing. Results show that the optimum arrangement is to locate a disk close to the inlet. 10 refs., 4 figs. (Author)

  7. Development of RCM analysis software for Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ho; Choi, Kwang Hee; Jeong, Hyeong Jong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1999-12-31

    A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear power plants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)

  8. Development of RCM analysis software for Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ho; Choi, Kwang Hee; Jeong, Hyeong Jong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A software called KEPCO RCM workstation (KRCM) has been developed to optimize the maintenance strategies of Korean nuclear power plants. The program modules of the KRCM were designed in a manner that combines EPRI methodologies and KEPRI analysis technique. The KRCM is being applied to the three pilot system, chemical and volume control system, main steam system, and compressed air system of Yonggwang Units 1 and 2. In addition, the KRCM can be utilized as a tool to meet a part of the requirements of maintenance rule (MR) imposed by U.S. NRC. 3 refs., 4 figs. (Author)

  9. Patient stress in intensive care: comparison between a coronary care unit and a general postoperative unit

    Science.gov (United States)

    Dias, Douglas de Sá; Resende, Mariane Vanessa; Diniz, Gisele do Carmo Leite Machado

    2015-01-01

    Objective To evaluate and compare stressors identified by patients of a coronary intensive care unit with those perceived by patients of a general postoperative intensive care unit. Methods This cross-sectional and descriptive study was conducted in the coronary intensive care and general postoperative intensive care units of a private hospital. In total, 60 patients participated in the study, 30 in each intensive care unit. The stressor scale was used in the intensive care units to identify the stressors. The mean score of each item of the scale was calculated followed by the total stress score. The differences between groups were considered significant when p < 0.05. Results The mean ages of patients were 55.63 ± 13.58 years in the coronary intensive care unit and 53.60 ± 17.47 years in the general postoperative intensive care unit. For patients in the coronary intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “being bored”. For patients in the general postoperative intensive care unit, the main stressors were “being in pain”, “being unable to fulfill family roles” and “not being able to communicate”. The mean total stress scores were 104.20 ± 30.95 in the coronary intensive care unit and 116.66 ± 23.72 (p = 0.085) in the general postoperative intensive care unit. When each stressor was compared separately, significant differences were noted only between three items. “Having nurses constantly doing things around your bed” was more stressful to the patients in the general postoperative intensive care unit than to those in the coronary intensive care unit (p = 0.013). Conversely, “hearing unfamiliar sounds and noises” and “hearing people talk about you” were the most stressful items for the patients in the coronary intensive care unit (p = 0.046 and 0.005, respectively). Conclusion The perception of major stressors and the total stress score were similar between patients

  10. Reversible arithmetic logic unit for quantum arithmetic

    DEFF Research Database (Denmark)

    Thomsen, Michael Kirkedal; Glück, Robert; Axelsen, Holger Bock

    2010-01-01

    This communication presents the complete design of a reversible arithmetic logic unit (ALU) that can be part of a programmable reversible computing device such as a quantum computer. The presented ALU is garbage free and uses reversible updates to combine the standard reversible arithmetic...... and logical operations in one unit. Combined with a suitable control unit, the ALU permits the construction of an r-Turing complete computing device. The garbage-free ALU developed in this communication requires only 6n elementary reversible gates for five basic arithmetic-logical operations on two n......-bit operands and does not use ancillae. This remarkable low resource consumption was achieved by generalizing the V-shape design first introduced for quantum ripple-carry adders and nesting multiple V-shapes in a novel integrated design. This communication shows that the realization of an efficient reversible...

  11. The PAMELA storage and control unit

    Energy Technology Data Exchange (ETDEWEB)

    Casolino, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy)]. E-mail: Marco.Casolino@roma2.infn.it; Altamura, F. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Basili, A. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); De Pascale, M.P. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Minori, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Nagni, M. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Picozza, P. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Sparvoli, R. [INFN, Structure of Rome II, Physics Department, University of Rome II ' Tor Vergata' , I-00133 Rome (Italy); Adriani, O. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Papini, P. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Spillantini, P. [INFN, Structure of Florence, Physics Department, University of Florence, I-50019 Sesto Fiorentino (Italy); Castellini, G. [CNR-Istituto di Fisica Applicata ' Nello Carrara' , I-50127 Florence (Italy); Boezio, M. [INFN, Structure of Trieste, Physics Department, University of Trieste, I-34147 Trieste (Italy)

    2007-03-01

    The PAMELA Storage and Control Unit (PSCU) comprises a Central Processing Unit (CPU) and a Mass Memory (MM). The CPU of the experiment is based on a ERC-32 architecture (a SPARC v7 implementation) running a real time operating system (RTEMS). The main purpose of the CPU is to handle slow control, acquisition and store data on a 2 GB MM. Communications between PAMELA and the satellite are done via a 1553B bus. Data acquisition from the sub-detectors is performed via a 2 MB/s interface. Download from the PAMELA MM towards the satellite main storage unit is handled by a 16 MB/s bus. The maximum daily amount of data transmitted to ground is about 20 GB.

  12. Understanding human trafficking in the United States.

    Science.gov (United States)

    Logan, T K; Walker, Robert; Hunt, Gretchen

    2009-01-01

    The topic of modern-day slavery or human trafficking has received increased media and national attention. However, to date there has been limited research on the nature and scope of human trafficking in the United States. This article describes and synthesizes nine reports that assess the U.S. service organizations' legal representative knowledge of, and experience with, human trafficking cases, as well as information from actual cases and media reports. This article has five main goals: (a) to define what human trafficking is, and is not; (b) to describe factors identified as contributing to vulnerability to being trafficked and keeping a person entrapped in the situation; (c) to examine how the crime of human trafficking differs from other kinds of crimes in the United States; (d) to explore how human trafficking victims are identified; and, (e) to provide recommendations to better address human trafficking in the United States.

  13. Data Sorting Using Graphics Processing Units

    Directory of Open Access Journals (Sweden)

    M. J. Mišić

    2012-06-01

    Full Text Available Graphics processing units (GPUs have been increasingly used for general-purpose computation in recent years. The GPU accelerated applications are found in both scientific and commercial domains. Sorting is considered as one of the very important operations in many applications, so its efficient implementation is essential for the overall application performance. This paper represents an effort to analyze and evaluate the implementations of the representative sorting algorithms on the graphics processing units. Three sorting algorithms (Quicksort, Merge sort, and Radix sort were evaluated on the Compute Unified Device Architecture (CUDA platform that is used to execute applications on NVIDIA graphics processing units. Algorithms were tested and evaluated using an automated test environment with input datasets of different characteristics. Finally, the results of this analysis are briefly discussed.

  14. The PAMELA storage and control unit

    International Nuclear Information System (INIS)

    Casolino, M.; Altamura, F.; Basili, A.; De Pascale, M.P.; Minori, M.; Nagni, M.; Picozza, P.; Sparvoli, R.; Adriani, O.; Papini, P.; Spillantini, P.; Castellini, G.; Boezio, M.

    2007-01-01

    The PAMELA Storage and Control Unit (PSCU) comprises a Central Processing Unit (CPU) and a Mass Memory (MM). The CPU of the experiment is based on a ERC-32 architecture (a SPARC v7 implementation) running a real time operating system (RTEMS). The main purpose of the CPU is to handle slow control, acquisition and store data on a 2 GB MM. Communications between PAMELA and the satellite are done via a 1553B bus. Data acquisition from the sub-detectors is performed via a 2 MB/s interface. Download from the PAMELA MM towards the satellite main storage unit is handled by a 16 MB/s bus. The maximum daily amount of data transmitted to ground is about 20 GB

  15. Radiation decontamination unit for the community hospital

    International Nuclear Information System (INIS)

    Waldron, R.L. II; Danielson, R.A.; Shultz, H.E.; Eckert, D.E.; Hendricks, K.O.

    1981-01-01

    Freestanding radiation decontamination units including surgical capability can be developed and made operational in small/medium sized community hospitals at relatively small cost and with minimal plant reconstrution. The Radiological Assistance Program of the United States Department of Energy and the Radiation Emergency Assistance Center Training Site of Oak Rige Associated Universities are ready to support individual hospitals and physicians in this endeavor. Adequate planning rather than luck, should be used in dealing with potential radiation accident victims. The radiation emergency team is headed by a physician on duty in the hospital. The senior administrative person on duty is responsible for intramural and extramural communications. Rapid mobilization of the radiation decontamination unit is important

  16. Energy options in the United Kingdom

    Energy Technology Data Exchange (ETDEWEB)

    Evans, S C [ed.

    1975-01-01

    The United Kingdom faces two issues: how can it survive the present massive increases in oil prices and the probability of even more expensive supplies in the future or how can it adjust to the eventual exhaustion of both fossil and nuclear fuels. The theme of the symposium concerned a search for a practical alternative source of energy to fossil and nuclear fuels and which ones would work in the United Kingdom. Papers were presented entitled: Geothermal Energy; Solar Energy in Britain; and Wind and Water Sources of Energy in the United Kingdom. A final paper, High- and Low-Growth Scenarios, examined these two types for the future. Many questions, answeres and comments about energy sources are contained in a final presentation. (MCW)

  17. A drier unit for steam separators

    International Nuclear Information System (INIS)

    Peyrelongue, J.-P.

    1973-01-01

    Description is given of a drier unit adapted to equip a water separator mounted in a unit for treating a wet steam fed from a high pressure enclosure, so as to dry and contingently superheat said steam prior to injecting same into a turbine low pressure stage. This drier unit is constituted by at least a stack of separating sheets maintained in parallel relationship and at a slight angle with respect to the horizontal so as to allow the water provided by wet steam to flow toward a channel communicating with a manifold, and by means for guiding the steam between the sheets and evenly distributing it. This can be applied to steam turbines in nuclear power stations [fr

  18. Quantum metrology foundation of units and measurements

    CERN Document Server

    Goebel, Ernst O

    2015-01-01

    The International System of Units (SI) is the world's most widely used system of measurement, used every day in commerce and science, and is the modern form of the metric system. It currently comprises the meter (m), the kilogram (kg), the second (s), the ampere (A), the kelvin (K), the candela (cd) and the mole (mol)). The system is changing though, units and unit definitions are modified through international agreements as the technology of measurement progresses, and as the precision of measurements improves. The SI is now being redefined based on constants of nature and their realization by quantum standards. Therefore, the underlying physics and technologies will receive increasing interest, and not only in the metrology community but in all fields of science. This book introduces and explains the applications of modern physics concepts to metrology, the science and the applications of measurements. A special focus is made on the use of quantum standards for the realization of the forthcoming new SI (the...

  19. Insuring unit failures in electricity markets

    International Nuclear Information System (INIS)

    Pineda, S.; Conejo, A.J.; Carrion, M.

    2010-01-01

    An electric energy producer participates in futures markets in the hope of hedging the risk of trading in the pool. However, this producer is required to supply the energy associated with all its signed forward contracts even if some of its units are forced out due to unexpected failures. In this case, the producer must purchase some of the energy needed to meet its futures market commitments in the pool, which may result in high losses if the pool prices happen to be higher than the forward contract prices. To mitigate these losses, the producer can take out insurance against the forced outages of its units. Using a stochastic programming model, this paper analyzes the convenience of signing an insurance against unit failure by an electric energy producer and its impact on forward contracting decisions. Results from a realistic case study are provided and analyzed.

  20. Procedural pain in neonatal units in Kenya.

    Science.gov (United States)

    Kyololo, O'Brien Munyao; Stevens, Bonnie; Gastaldo, Denise; Gisore, Peter

    2014-11-01

    To determine the nature and frequency of painful procedures and procedural pain management practices in neonatal units in Kenya. Cross-sectional survey. Level I and level II neonatal units in Kenya. Ninety-five term and preterm neonates from seven neonatal units. Medical records of neonates admitted for at least 24 h were reviewed to determine the nature and frequency of painful procedures performed in the 24 h period preceding data collection (6:00 to 6:00) as well as the pain management interventions (eg, morphine, breastfeeding, skin-to-skin contact, containment, non-nutritive sucking) that accompanied each procedure. Neonates experienced a total of 404 painful procedures over a 24 h period (mean=4.3, SD 2.0; range 1-12); 270 tissue-damaging (mean=2.85, SD 1.1; range 1-6) and 134 non-tissue-damaging procedures (mean=1.41, SD 1.2; range 0-6). Peripheral cannula insertion (27%) and intramuscular injections (22%) were the most common painful procedures. Ventilated neonates and neonates admitted in level II neonatal units had a higher number of painful procedures than those admitted in level I units (mean 4.76 vs 2.96). Only one procedure had a pain intensity score documented; and none had been performed with any form of analgesia. Neonates in Kenya were exposed to numerous tissue-damaging and non-tissue-damaging procedures without any form of analgesia. Our findings suggest that education is needed on how to assess and manage procedural pain in neonatal units in Kenya. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.