WorldWideScience

Sample records for years physikalisch-technische qualitaetssicherung

  1. Duties of the Physikalisch-Technische Bundesanstalt (PTB) in connection with radioactive waste safeguarding and ultimate storage

    International Nuclear Information System (INIS)

    Roethemeyer, H.

    1977-01-01

    An outline of the history and duties of the Physikalisch-Technische Bundesanstalt (PTB) is to illustrate that the new duties of the PTB in connection with radioactive substance safeguarding and ultimate storage fit in very well with the range of duties of the PTB. The organisatory and technical accomplishment of these duties in cooperation with a building and operating company and with industry is explained. The department of the PTB for the 'safeguarding and ultimate storage of radioactive wastes' has an examining, appraising and licensing function in connection with construction, operation and shutdown of safety facilities. Methods for the safeguarding and ultimate storage of all the radioactive wastes in the Federal Republic of Germany are described. (HS) [de

  2. Measuring instruments of the Physikalisch-Technische Bundesanstalt for realization of the units of the dosimetric quantities standard ion dose, photon-equivalent dose and air-kerma

    International Nuclear Information System (INIS)

    Engelke, B.A.; Oetzmann, W.; Struppek, G.

    1988-08-01

    The realization of the units of the dosimetric quantities exposure, air-kerma and photon-equivalent dose is an important task of the Physikalisch-Technische Bundesanstalt. The report describes the measuring instruments and other technical equipment as well as the determination of the numerous corrections needed. All data and correction factors required for the realization of the units mentioned above are given in many diagrams and tables. (orig.) [de

  3. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt; Medicion de curvas de extrapolacion para el patron secundario de radiacion beta Nr. 86 calibrado en rapidez de dosis absorbida para tejido equivalente por el Physikalisch Technische Bundesanstalt

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T

    1988-10-15

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  4. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1988-10-01

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  5. Requirements of the Physikalisch-Technische Bundesanstalt (PTB) for therapy dosemeters with ionization chambers submitted for calibration and approval

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    Therapy dosemeters are subject to calibration as from January 1, 1983 according to section 3 of the second ordinance concerning the obligation to calibrate measuring instruments (in the version of the ordinance concerning the amendment of the second and third ordinance about the obligation to calibrate measuring instruments of December 21, 1979, Federal Gazette I p 2347). Section 4 subsection 2 of this ordinance determines a transitional period until December 31, 1985. In this transitional period those therapy dosemeters may be used without calibration which were already in use on January 1, 1983. The requirements of the PTB correspond to the established rules of technology. They specify and complete the provisions of the standardization regulations and establish terms and conditions of the test. They passed the general assembly of the Physikalisch-Technische Bundesanstalt concerning calibration and measurement of 1982. The requirements of the PTB stipulate the admissible limits for effects of numerous influencing factors and other properties of the equipment and tolerances of calibration and handling. (orig.) [de

  6. Physikalisch-Technische Bundesanstalt (PTB). Annual report 2015; Physikalisch-Technische Bundesanstalt (PTB). Jahresbericht 2015

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-03-15

    ''PTB's central mission and the demands it places on itself are to make available an innovative metrological infrastructure at the highest international level in Germany to promote Germany's export-oriented high-tech economy, to meet the demands of a complex society and to support science that is operating at the cutting edge worldwide.'' This is what is stated in the ''Agreement on Objectives'' for the years from 2015 to 2019 between the Federal Ministry for Economic Affairs and Energy (Bundesministerium fuer Wirtschaft und Energie - BMWi) and PTB, which was signed on 12 January 2016 by State Secretary Machnig and me. Both this agreement and the newly developed ''Work and research program 2015 to 2017'' thus clearly define PTB's medium-term guidelines focusing on ''Innovation and industry'', ''Energy and the environment'', ''Humans and health'', ''Legal and international metrology'' as well as ''The new System of Units''.

  7. Physikalisch-Technische Bundesanstalt (PTB). Annual report 2016; Physikalisch-Technische Bundesanstalt (PTB). Jahresbericht 2016

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-03-15

    The following topics are dealt with: Quality management, legal metrology, technology transfer, technical cooperation, mechanics and acoustics, chemical physics and explosion protection, optics, manufacturing measurement techniques, ionizing radiation, temperature and synchrotron radiation, medical physics and metrological information techniques. (HSI)

  8. Physikalisch-Technische Bundesanstalt (PTB). Annual report 2015

    International Nuclear Information System (INIS)

    2016-03-01

    ''PTB's central mission and the demands it places on itself are to make available an innovative metrological infrastructure at the highest international level in Germany to promote Germany's export-oriented high-tech economy, to meet the demands of a complex society and to support science that is operating at the cutting edge worldwide.'' This is what is stated in the ''Agreement on Objectives'' for the years from 2015 to 2019 between the Federal Ministry for Economic Affairs and Energy (Bundesministerium fuer Wirtschaft und Energie - BMWi) and PTB, which was signed on 12 January 2016 by State Secretary Machnig and me. Both this agreement and the newly developed ''Work and research program 2015 to 2017'' thus clearly define PTB's medium-term guidelines focusing on ''Innovation and industry'', ''Energy and the environment'', ''Humans and health'', ''Legal and international metrology'' as well as ''The new System of Units''.

  9. A Focus of Discoveries

    CERN Document Server

    Huebener, Rudolf Peter

    2008-01-01

    In 1887, the Physikalisch-Technische Bundesanstalt (PTB) was originally founded as the Physikalisch-Technische Reichsanstalt (PTR) in Berlin in order to promote basic research in physics. It subsequently developed into the largest research center worldwide as a place where scientists could concentrate exclusively on their research subject, and served as a model for similar institutes established in other countries.Within a very short time, the PTR produced extremely important scientific results that cemented its international position at the top, such as Max Planck's radiation law and energy q

  10. Quality assurance and quality control of analytic data produced within the Association for Research on Heavy Metal Emissions; Qualitaetssicherung und Qualitaetskontrolle der analytischen Daten aus dem Forschungsverbund Edelmetallemissionen

    Energy Technology Data Exchange (ETDEWEB)

    Wegscheider, W [Montanuniversitaet Leoben (Austria). Inst. fuer Allgemeine und Analytische Chemie

    1998-12-31

    In many fields of scientific research formalised quality assurance is not common practice. The present promotional measure by the Federal Ministry for Education and Research was nevertheless provided with an own research project for external quality assurance. This paper reports on the orientation and execution of the project. [Deutsch] Formalisierte Qualitaetssicherung ist ueber weite Bereiche in der naturwissenschaftlichen Forschung nicht ueblich. Fuer diese Foerdermassnahme des BMBF wurde dennoch ein eigenes Forschungsvorhaben zur externen Qualitaetssicherung eingerichtet ueber dessen Ausrichtung und Durchfuehrung im folgenden berichtet wird. (orig.)

  11. Quality assurance and quality control of analytic data produced within the Association for Research on Heavy Metal Emissions; Qualitaetssicherung und Qualitaetskontrolle der analytischen Daten aus dem Forschungsverbund Edelmetallemissionen

    Energy Technology Data Exchange (ETDEWEB)

    Wegscheider, W. [Montanuniversitaet Leoben (Austria). Inst. fuer Allgemeine und Analytische Chemie

    1997-12-31

    In many fields of scientific research formalised quality assurance is not common practice. The present promotional measure by the Federal Ministry for Education and Research was nevertheless provided with an own research project for external quality assurance. This paper reports on the orientation and execution of the project. [Deutsch] Formalisierte Qualitaetssicherung ist ueber weite Bereiche in der naturwissenschaftlichen Forschung nicht ueblich. Fuer diese Foerdermassnahme des BMBF wurde dennoch ein eigenes Forschungsvorhaben zur externen Qualitaetssicherung eingerichtet ueber dessen Ausrichtung und Durchfuehrung im folgenden berichtet wird. (orig.)

  12. Physikalisch-Technische Bundesanstalt (PTB). Annual report 1994

    International Nuclear Information System (INIS)

    1995-03-01

    The annual report presents general information on the institution's activities and the various departments, and reports on scientific work in the field of metrology and safety engineering. Brief scientific accounts refer to work in the domains of mechanics and acoustics, electricity, heat, optics, industrial metrology, atomic physics, technical and scientific services, collection and disposal of radioactive waste. (orig.) [de

  13. Physikalisch-Technische Bundesanstalt (PTB). Annual report 2006

    International Nuclear Information System (INIS)

    2007-03-01

    The following topics are dealt with: Mechanics and acoustics, electricity, chemical physics and explosion protection, optics, manufacturing measureing techniques, ionizing radiation, temperature and synchrotron radiation, medical physics and metrological information techniques, the German calibration service, quality management. (HSI)

  14. An international intercomparison of passive dosemeters, electronic dosemeters and dose rate meters used for environmental radiation measurements

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Thompson, I.M.G.

    1995-01-01

    during 1994. The intercomparison was organised by the Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany, and by the Riso National Laboratory, Roskilde, Denmark. This paper describes the intercomparison experiments performed at the newly established Riso Natural Environmental Radiation...

  15. Progress report on reversal and substitute element technique for thread calibration on CMMs

    DEFF Research Database (Denmark)

    Carmignato, Simone; Larsen, Erik; Sobiecki, Rene

    . For this project, the Centre for Geometrical Metrology (CGM) at the Technical University of Denmark (DTU) takes care of thread measurements, in collaboration with Dipartimento di Innovazione Meccanica e Gestionale (DIMEG) - University of Padova - Italy, Physikalisch-Technische Bundesanstalt Braunschweig (PTB...

  16. Feasibility of the reversal and substitute element technique for thread calibration

    DEFF Research Database (Denmark)

    Larsen, Erik; Carmignato, Simone; De Chiffre, Leonardo

    . For this project, the Centre for Geometrical Metrology (CGM) at the Technical University of Denmark (DTU) takes care of thread measurements, in collaboration with Dipartimento di Innovazione Meccanica e Gestionale (DIMEG) - University of Padova - Italy, Physikalisch-Technische Bundesanstalt Braunschweig (PTB...

  17. Accelerated degeneration testing for flowmeter sensors. Evaluation and constancy against measuring; Beschleunigte Abnutzungspruefung fuer Durchflusssensoren. Abschaetzung der Messbestaendigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Juergen; Fenske, Helmut; Gerdes, Oda [Physikalisch-Technische Bundesanstalt (PTB), Berlin (Germany). Fachbereich Waerme

    2009-01-15

    Test specifications for flow sensors state that a fatigue test should be carried out for 2400 h. The PTB (Physikalisch-Technische Bundesanstalt), in cooperation with industrial organisations, developed a faster fatigue test for mechanical and static sensors which requires only 600 h. (orig.)

  18. Seminar series on `Technical building installations`. The example of refrigeration technology for air conditioning plants. Practice-oriented advanced training at Technische Akademie Esslingen training centre. Seminar series on `Technical building installations`; Lehrgangsreihe ``Technische Gebaeudeausruestung``. Beispiel: Kaeltetechnik in Klimaanlagen. Praxisnahe Fortbildung am Weiterbildungszentrum Technische Akademie Esslingen. Lehrgangsreihe ``Technische Gebaeudeausruestung``

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-04-01

    The advanced training on ``Technical Building Installations`` at the Technische Akademie Esslingen has been held regularly over a period of 18 years now. The training lasts several days and comprises a total of 12 courses on the subjects: ventilation and air-conditioning, stages A-D; refrigeration, stage A; refrigeration in air conditioning glants; energy concepts for buildings and industry, stages A and B; heating in old and new buildings; sanitation, stages A and B; and, sanitation in old and new buildings. In the present article the structure of the training is illustrated for the example of refrigeration in air conditioning plants. The article also discusses questions concerning the assessment of the training and its benefit to the participants. (BWI) [Deutsch] Seit nunmehr 18 Jahren wird an der Technischen Akademie Esslingen TAE die mehrtaegige Fortbildungsveranstaltung ``Technische Gebaeudeausruestung`` durchgefuehrt. Insgesamt werden in diesem gesamten Themenkomplex 12 Lehrgaenge angeboten: Raumlufttechnik, Teil A-D; Kaeltetechnik Teil A - Kaeltetechnik in Klimaanlagen, Energiekonzepte fuer Gebaeude und Industrie, Teil A und B, Heiztechnik in Neu- und Altbauten, Sanitaertechnik Teil A und B. Am Beispiel des Themenbereiches Kaeltetechnik in Klimaanlagen wird die Lehrgangsausrichtung dargestellt. Ferner werden Fragen der Lehrgangsbewertung und der Nutzen fuer die Teilnehmer diskutiert. (BWI)

  19. Physical water treatment against calcification and rust; Physikalische Wasserbehandlung gegen Kalk und Rost

    Energy Technology Data Exchange (ETDEWEB)

    Burger, A [Hydrotec AG, Rehau (Germany). Forschung und Entwicklung

    1995-03-01

    In contrast to Germany, where the installation of small-sized, decentralised plants is still prefered, water supply companies in countries such as Denmark have already for some time successfully been using physical water treatment systems. Although the health and environmental benefits of this non-chemical method of water treatment are undisputed and its proper application is also economically beneficial, there is still a widerspread lack of information as to where such plants can be used. Consequently, older methods are often resorted to combatting calcification and rust. (orig.) [Deutsch] Waehrend in Laendern wie Daenemark physikalische Wasserbehandlungssysteme bereits seit laengerem erfolgreich von Wasserversorgungsunternehmen eingesetzt werden, ueberwiegt in Deutschland bislang der dezentrale Einbau meist kleinerer Geraete. Obwohl der Nutzen dieser Form chemiefreier Wasserbehandlung fuer Umwelt und Gesundheit ausser Frage steht, zudem bei richtiger Verwendung deutliche Kostenvorteile entstehen, besteht noch haeufig Unsicherheit ueber die Einsatzgebiete physikalischer Wasserbehandlungsgeraete. Dies fuehrt haefig dazu, beim Kampf gegen Kalk und Rost auf aeltere Verfahren zurueckzugreifen. (orig.)

  20. New ways for the coordination of research for the dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Schuhmacher, Helmut

    2009-01-01

    The European Radiation Dosimetry Group (EURADOS) is a network of about 50 institutions from nearly oil European countries which coordinates research and development for the dosimetry of ionizing radiation. EURADOS was supported over many years by the European Communities. Since 2008 EURADOS is registered as a non-profit society (eingetragener Verein, e.V.) in Braunschweig with the office at the Physikalisch-Technische Bundesanstalt (PTB). This new formal status and the related independence from European research programmes allows new ways in the coordination of research. (orig.)

  1. Comprehensive understanding of mole concept subject matter according to the tetrahedral chemistry education (empirical study on the first-year chemistry students of Technische Universität Dresden)

    Science.gov (United States)

    Prabowo, D. W.; Mulyani, S.; van Pée, K.-H.; Indriyanti, N. Y.

    2018-05-01

    This research aims to apprehend: (1) the shape of tetrahedral chemistry education which is called the future of chemistry education, (2) comprehensive understanding of chemistry first-year students of Technische Universität Dresden according to the chemistry education’s tetrahedral shape on mole concept subject matter. This research used quantitative and qualitative; paper and pencil test and interview. The former was conducted in the form of test containing objective test instrument. The results of this study are (1) learning based on tetrahedral shape of chemistry education put the chemical substance (macroscopic), symbolic representation (symbol), and its process (molecular) in the context of human beings (human element) by integrating content and context, without emphasis on one thing and weaken another, (2) first-year chemistry students of Technische Universität Dresden have comprehensively understood the mole concept associated with the context of everyday life, whereby students are able to find out macroscopic information from statements that are contextual to human life and then by using symbols and formulas are able to comprehend the molecular components as well as to interpret and analyse problems effectively.

  2. Absolute Measurement of Radioactive Materials at the Physikalisch-Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Weiss, H. M.

    1960-01-01

    A short report is given about the routine methods of standardization of radionuclides. The measurements are done by 4 π β proportional counters, 4 π β-γ coincidence counting and for secondary standardization of γ emitters by 4 π γ ionization chamber. The equipments used and the procedures of source preparation are described. (author) [fr

  3. Utilization of the research and measurement reactor Braunschweig for neutron metrology

    International Nuclear Information System (INIS)

    Alberts, W.G.

    1982-01-01

    The objectives of the Physikalisch-Technische Bundesanstalt (PTB) with regard to neutron metrology are briefly described. The use of the PTB's Research and Measuring Reactor as neutron source for metrological purposes is discussed. Reference neutron beams are described which serve as irradiation facilities for the calibration of detectors for radiation protection purposes in the frame of the legal metrology work in the PTB. (orig.) [de

  4. Evaluation of disposal possibilities and potential in the Konrad iron-ore mine based on experiments for the handling and isolation of radioactive wastes

    International Nuclear Information System (INIS)

    Brewitz, W.

    1984-01-01

    The Gesellschaft fuer Strahlen und Umwelftorschung (GSF) has established, at the conclusion of feasibility studies, that the suitability of the Konrad mine for the disposal of low-level waste and decommisioning waste has been proved, as well as the radiological safety of the disposal operations. On 31 August 1982, the Physikalisch-Technische Bundesanstalt (PTB) submitted an application for licensing to the State Authority of Lower Saxony

  5. Technische Planologie in beweging, naar een hoge kwaliteit in onderwijs

    NARCIS (Netherlands)

    Ike, P.

    2008-01-01

    In de oratie wordt een beeld geschetst van de ontwikkeling van de opleiding Technische Planologie en de daarmee samenhangende internationalisering. Tevens wordt het onderwijs-kwaliteitszorg-systeem zoals dat vanaf 2008 binnen de RUG zal worden opgezet nader belicht.

  6. Photon and electron dosimetry at the Physikalisch-Technische Bundesanstalt in Braunschweig

    International Nuclear Information System (INIS)

    Reich, H.

    1983-12-01

    The PTB is charged by the government to prepare the legal control for dosimeters used in radiotherapy and radiation protection by setting up requirements for type approvals and by developing the technical prerequisites for performing type tests. Based on international recommendations, the change of units had to be connected with a change of quantities. The exposure had to be changed either to kerma or to absorbed dose or to dose equivalent. (DG)

  7. Comparison of temperature standards. 800 deg C to 1500 deg C (radiation pyrometers). Pt. 2

    International Nuclear Information System (INIS)

    Jimenez Rebagliati, M.; Hildebrand, E.; Tischler, M.

    1990-01-01

    A comparison between implementations of the temperature scale (IPTS-68) between 800 deg C to 1500 deg C was made at the Department of Physics and Metrology at INTI, using pyrometric lamps with a tungsten filament which were calibrated at the Physikalisch-Technische Bundesanstalt (PTB). The purpose of this analysis was the detection of possible systematic errors as well as the evaluation of the uncertainty limit. (Author) [es

  8. Haalbaarheidsstudie bio-afbreekbare plastic draagtasjes : technische en economische haalbaarheid en implicaties

    NARCIS (Netherlands)

    Oever, van den M.J.A.; Bolck, C.H.; Bos, H.L.; Molenveld, K.; Zee, van der M.; Schennink, G.G.J.

    2014-01-01

    Dit rapport beschrijft de resultaten van een haalbaarheidsstudie naar de technische en economische haalbaarheid en implicaties van een verbod op dunne plastic draagtasjes in Nederland, met een eventuele uitzondering voor bioplastic draagtassen. In deze korte studie staan bioplastic draagtassen

  9. The German thoron progeny chamber-Concept and application

    International Nuclear Information System (INIS)

    Roettger, Annette; Honig, Anja; Arnold, Dirk

    2009-01-01

    Following completion of the project 'Generation and characterisation of reference atmospheres of thoron decay products for the calibration of measuring devices for thoron decay products', the Physikalisch-Technische Bundesanstalt (PTB) now operates a thoron progeny chamber in which 220 Rn (thoron), 222 Rn and its progenies can be made available under almost all ambient conditions. This allows all measuring systems to be calibrated under realistic climatic conditions with an accuracy unique worldwide.

  10. Bunsen conference 1999. Atmospheric physical chemistry; Bunsentagung 1999. Physikalische Chemie der Atmosphaere

    Energy Technology Data Exchange (ETDEWEB)

    Crutzen, P.J.; Zellner, R. [comps.

    2000-07-01

    The main subject of the 1999 Bunsen conference was atmospheric physical chemistry. There were lectures and posters on measurement and distribution of atmospheric trace gases, photochemical reactions in the different parts of the atmosphere, natural and anthropogenic emissions resulting from biomass combustion, thermodynamics and microphysics of aerosol, and air pollution abatement. [German] Die Bunsentagung 1999 beschaeftigte sich mit dem Thema Physikalische Chemie der Atmosphaere. Themen der Vortraege und Poster waren u.a. die Messung und Verteilung von Spurengasen in der Atmosphaere, photochemische Reaktionen in den verschiedenen Schichten der Atmosphaere, natuerliche und anthropogene Emissionen durch Verbrennung von Biomasse, Thermodynamik und Microphysik von Aerosolen und Klimaschutz.

  11. Review on common calibration and measurement practises for measuring gears on CMMs

    DEFF Research Database (Denmark)

    Sammatini-Malberg, Maria-Pia; De Chiffre, Leonardo

    , in order to give an overview of the improvements achieved in the last 25 years. Special attention is paid to gear metrology on coordinate measuring machines (CMMs). Calibration chains for the major gear geometrical quantities developed by Physikalisch-Technische Bundesanstalt (PTB) as well as their recent...... results obtained in gear standards measurement uncertainties are presented. This review also describes the design and development of a new type of master gear: the Gauge Block Gear (GBG).The GBG was developed for the performance verification of CMMs, for the specific task of pitch and chordal tooth...... thickness measurement. Its main characteristic is the replacement of the teeth with gauge blocks, in order to achieve direct traceability of the chordal tooth thickness...

  12. Vrouwen weg van techniek : waarom verlaten technisch opgeleide vrouwen de techniek?

    NARCIS (Netherlands)

    Sjiera de Vries; I.A. Strijker; Rabia Çoban

    2015-01-01

    1.1 Techniek verliest talent Verschillende branches in de technische sector kampen met een tekort aan personeel en de verwachting is dat deze tekorten ook in de komende jaren zullen blijven bestaan (ROA, 2013). Om de tekorten op te vangen wordt hard gewerkt aan het motiveren van jongeren om een

  13. Physical and technical aspects of cryomedicine. Physikalische und technische Aspekte der Kryomedizin

    Energy Technology Data Exchange (ETDEWEB)

    Spoerl, E. (Medizinische Akademie, Dresden (Germany)); Krantz, H. (Medizinische Akademie, Dresden (Germany))

    1993-01-01

    Some of the functional principles of cryomedical device engineering, the special features of heat transmission at the tissue surface and a model for calculating treatment parameters are presented for a discussion of focal cold application dosed according to indication. The elaboration of the physico-technical basics of cryotherapy has contributed to the development of this originally empirically oriented method to a safe and widely accepted therapeutic procedure. (orig.)

  14. VT-NRK Toepassing bioplastics : verbeteren van de technische eigenschappen van PLA-folies

    NARCIS (Netherlands)

    Molenveld, K.; Schennink, G.G.J.

    2009-01-01

    Het doel van dit project, VT-NRK toepassing bioplastics, is het genereren en verspreiden van kennis met betrekking tot het verbeteren van de technische eigenschappen van PLA folies. De kennis is bedoeld voor de bedrijven die binnen de kunststofindustrie aangesloten zijn bij de MJA én folies

  15. Determination of the neutron detection efficiency of an NE213 scintillator for En=2.5 to 16 MeV using the 2H(d,n)3He reaction

    International Nuclear Information System (INIS)

    Al-Ohali, M.A.; Aksoy, A.; Coban, A.

    1997-01-01

    The absolute efficiency of an NE213 liquid scintillator of 12.7 cm diameter and 5.08 cm thickness was measured in the neutron energy range 2.5-16 MeV using the 2 H(d,n) 3 He reaction as a source of monoenergetic neutrons. The efficiencies were measured at the time-of-flight facility of Triangle Universities Nuclear Laboratory TUNL. The experimental data are compared to calculations from the Monte Carlo code NEFF of Physikalisch-Technische Bundesanstalt, Braunschweig, Germany PTB. (orig.)

  16. Quality control of radionuclide calibrators: Interlaboratory comparison of thallium-201

    International Nuclear Information System (INIS)

    Debertin, K.

    1985-01-01

    After 131 I and sup(99m)Tc comparisons in 1982 and 1983, the Physikalisch-Technische Bundesanstalt (PTB) in cooperation with the firm Amersham-Buchler organized a further comparison in October 1984 in order to investigate the accuracy of activity measurements in nuclear medicine. 48 hospitals or institutes participated in this 201 TI comparison. The wast majority of the reported results agreed with the PTB-value to within 10%, however in 5 cases deviations amounted to more than 20%. (orig.) [de

  17. Air-cooled recirculation cooling systems. Technical and economic comparison; Luftgekuehlte Rueckkuehlsysteme. Technisch wirtschaftlicher Vergleich

    Energy Technology Data Exchange (ETDEWEB)

    Dierks, G. [Fa. Jaeggi/Guentner (Schweiz) AG, Trimbach (Switzerland)

    2000-03-01

    There are several air-cooled forced-circulation cooling systems for heat removal from refrigeration systems. Optimum solutions should not be selected on the basis of the cost factor alone; an integrative approach should be used instead. An exemplary investigation is presented. [German] Fuer die Waermeabfuhr aus kaeltetechnischen Anlagen stehen verschiedene luftgekuehlte, zwangsbelueftete Rueckkuehlsysteme zur Verfuegung. Die Auswahl des Systems ist oft von kurzfristigem Kostendenken gepraegt, was in technischer und wirtschaftlicher Hinsicht aber nicht immer der optimalen Loesung entspricht. Erst die genauere Kenntnis der verschiedenen Systeme und eine ganzheitliche Betrachtungsweise ermoeglichen die optimale Wahl fuer den einzelnen Fall. Die hier praesentierte Untersuchung wird anhand eines konkreten Falls dargestellt, wobei Preise und technische Produktdaten auf realen Anfragen beruhen. Der Autor ist um objetive Bewertung bemueht, der Leser moege aber selbst urteilen. (orig./AKF)

  18. Ammoniakemissie-arme huisvestingssystemen voor vleeskuikens en het effect van vloerverwarming op emissie en technische resultaten

    NARCIS (Netherlands)

    Middelkoop, van J.H.; Harn, van J.

    1995-01-01

    Het Praktijkonderzoek Pluimveehouderij heeft onderzoek gedaan naar het gebruik van emissiearme stalsystemen voor vleeskuikens en het effect van het gebruik van vloerverwarming op de technische resultaten, strooiselkwaliteit en ammoniakemissie.

  19. Investigation of Calibrating Force Transducer Using Sinusoidal Force

    International Nuclear Information System (INIS)

    Zhang Li; Wang Yu; Zhang Lizhe

    2010-01-01

    Sinusoidal force calibration method was studied several years before at Physikalisch-Technische Bundesanstalt (PTB). A similar dynamic force calibration system is developed at Changcheng Institute of Metrology and Measurement (CIMM). It uses electro-dynamic shakers to generate dynamic force in the range from 1 N to 20 kN, and heterodyne laser interferometers are used for acceleration measurement. The force transducer to be calibrated is mounted on the shaker, and a mass block is screwed on the top of force transducer, the sinusoidal forces realized by accelerated load masses are traceable to acceleration and mass according to the force definition. The methods of determining Spatial-dependent acceleration on mass block and measuring the end mass of force transducer in dynamic force calibration are discussed in this paper.

  20. BESSY annual report 1991

    International Nuclear Information System (INIS)

    1992-01-01

    The annual report 1991 is drawn up as in the previous years, with general information on the organisational structure of the institution and its general purposes being given ahead of the research-specific reports. The achievements and developments in the fields of machines and experiments are reported, including contributions from the Litography laboratory of the Fraunhofer Institute for Microstructural Studies and Techniques, and from the Radiometry Laboratory of the Physikalisch-Technische Bundesanstalt, followed by reports on basic research work. The machine developments are reported in varions contributions, and a list of publications shows all available and known scientific publications resulting from research work done at the BESSY installations by the various users. Diploma, doctoral and habilitation theses are listed separately. (orig.) [de

  1. Determination of the neutron detection efficiency of an NE213 scintillator for E{sub n}=2.5 to 16 MeV using the {sup 2}H(d,n){sup 3}He reaction

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ohali, M.A.; Aksoy, A.; Coban, A. [King Fahd Univ. of Pet. and Miner., Dhahran (Saudi Arabia). Energy Res. Lab.; Hanly, J.M.; Felsher, P.D.; Howell, C.R.; Tornow, W.; Salinas, F.; Walter, R.L. [Duke University and Triangle Universities Nuclear Laboratories, Durham, NC 27708 (United States)

    1997-09-11

    The absolute efficiency of an NE213 liquid scintillator of 12.7 cm diameter and 5.08 cm thickness was measured in the neutron energy range 2.5-16 MeV using the {sup 2}H(d,n){sup 3}He reaction as a source of monoenergetic neutrons. The efficiencies were measured at the time-of-flight facility of Triangle Universities Nuclear Laboratory TUNL. The experimental data are compared to calculations from the Monte Carlo code NEFF of Physikalisch-Technische Bundesanstalt, Braunschweig, Germany PTB. (orig.). 7 refs.

  2. Workplace photon radiation fields

    International Nuclear Information System (INIS)

    Burgess, P.H.; Bartlett, D.T.; Ambrosi, P.

    1999-01-01

    The knowledge of workplace radiation fields is essential for measures in radiation protection. Information about the energy and directional distribution of the incident photon radiation was obtained by several devices developed by the National Radiation Protection Board, United Kingdom, by the Statens Stralskyddsinstitut, Sweden, together with EURADOS and by the Physikalisch-Technische Bundesanstalt, Germany. The devices are described and some results obtained at workplaces in nuclear industry, medicine and science in the photon energy range from 20 keV to 7 MeV are given. (author)

  3. Preliminary waste acceptance requirements for the planned Konrad repository

    International Nuclear Information System (INIS)

    Warnecke, E.; Brennecke, P.

    1987-01-01

    The Physikalisch-Technische Bundesanstalt (PTB) has established Preliminary Waste Acceptance Requirements for the planned Konrad repository. These requirements were developed, in accordance with the Safety Criteria of the Reactor Safety Commission, with the help of a site specific safety assessment; they are under the reservation of the plan approval procedure, which is still in progress. In developing waste acceptance requirements, the PTB fulfills one of its duties as the institute responsible for waste disposal and gives guidelines for waste conditioning to waste producers and conditioners. (orig.) [de

  4. Physical interactions in MRI. Some rules of thumb for their reduction; Physikalische Wechselwirkungen in der MRT. Einige Daumenregeln zu ihrer Reduktion

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany); Trattnig, S. [Medizinische Universitaet Wien, Exzellenzzentrum Hochfeld-Magnetresonanz, Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2015-08-15

    Magnetic resonance imaging (MRI) is one of the most powerful and at the same time gentlest clinical imaging techniques at the present time; however, the enormous physical complexity as well as simple inattentiveness (projectile effect) implicate a significant risk potential and place high demands on the MR operator to ensure a safe workflow. A sound knowledge of the potential MR interactions is the foundation for a safe and profitable operation for all parties. The first part of this article deals with the three most important sources of physical interaction, i.e. static magnetic field, gradient and high-frequency (HF) fields. The paper discusses the differences between each type of field with respect to the impact on human beings, the interactions with magnetic and electrically conducting objects/implants and the relevant safety standards. Each section is followed by simple rules of thumb to minimize potentially unwanted physical MRI interactions. (orig.) [German] Die Magnetresonanztomographie ist eines der leistungsfaehigsten und zugleich schonendsten klinischen bildgebenden Verfahren der heutigen Zeit. Allerdings bergen ihre enorme physikalische Komplexitaet, aber auch einfache Unaufmerksamkeiten (''Projektileffekt'') ein signifikantes Risikopotenzial in sich und stellen hohe Anforderungen an die MR-Bediener, um einen sicheren Betrieb zu gewaehrleisten. Ein solides Wissen um die potenziellen MR-Wechselwirkungen ist die Grundlage fuer einen sicheren und fuer alle Seiten gewinnbringenden Betrieb. Der erste Teil der Arbeit behandelt die 3 zentralen Quellen fuer physikalische Wechselwirkungen in der Magnetresonanztomographie (statisches Magnetfeld, geschaltete Gradienten- und HF-Felder). Es werden fuer jede Feldart die Auswirkungen auf den Menschen, Wechselwirkungen mit magnetischen und elektrisch leitenden Objekten/Implantaten und relevante Sicherheitsstandards besprochen. Daran angeschlossen ist jeweils ein Abschnitt mit einfachen &apos

  5. Präparation spezieller Biokatalysatoren für die chemisch-technische Nutzung zur Bereitstellung von Aromaten und chiralen α-Hydroxyketonen

    OpenAIRE

    Bieler, Nora Christiane

    2011-01-01

    Teil 1 Bereitstellung der Biokatalysatoren LAC, LiP und MnP für deren chemisch-technische Nutzung Die drei Oxidoreduktasen Laccase (LAC), Lignin- und Manganperoxidase (Li- und MnP) aus Weißfäulepilzen sind technisch sehr interessant, da sie unter Anderem Lignin abbauen können. Vor allem deren zeitaufwändige Produktion in den ligninolytischen Organismen limitiert jedoch industrielle Anwendungen. Daher wurden Möglichkeiten zur Bereitstellung dieser Biokatalysatoren überprüft. So war es Ziel, di...

  6. Lessons learnt from an international intercomparison of national network systems used to provide early warning of a nuclear accident

    DEFF Research Database (Denmark)

    Saez-Vergara, J.C.; Thompson, I.M.G.; Funck, E.

    2003-01-01

    and at the Underground Laboratory for Dosimetry and Spectrometry (UDO) of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The network systems are used continuously to monitor radiation levels throughout a country in order to give early warning of nuclear accidents having transboundary implications...... in order to be consistent with the preliminary report. In addition, in some cases the results are also given in terms of the quantity measured by each national network system. The experience gained from this intercomparison is used to help organise a follow-up intercomparison to be held at the PTB...

  7. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the PTB and the BIPM

    International Nuclear Information System (INIS)

    Kessler, C.; Allisy-Roberts, P.J.; Selbach, H.J.

    2015-01-01

    An indirect comparison of the standards for reference air kerma rate (RAKR) for 192 Ir high dose rate (HDR) brachytherapy sources of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the PTB in September 2011. The comparison result, based on the calibration coefficients for a transfer standard and expressed as a ratio of the PTB and the BIPM standards for reference air kerma rate, is 1.0003 with a combined standard uncertainty of 0.0099. (authors)

  8. Determination of the air attenuation correction factor for a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia F.; Cintra, Felipe B.; Castro, Maysa C. de; Caldas, Linda V.E.

    2016-01-01

    The objective of this work is to present the experimental and simulation results for the air attenuation correction factor for a free air ionization chamber with concentric cylinders of Victoreen, model 481-5. This correction factor was obtained for the standard mammography qualities established in the Instrument Calibration Laboratory (LCI) of IPEN. The values were compared with the results from the German primary standard laboratory Physikalisch- Technische Bundesanstalt (PTB), and maximum differences of 0.40% in relation to the experimental value and 0.31% in relation to the simulated value were obtained. (author)

  9. Secondary standard dosimetry laboratory at INFLPR

    Energy Technology Data Exchange (ETDEWEB)

    Scarlat, F.; Minea, R.; Scarisoreanu, A.; Badita, E.; Sima, E.; Dumitrascu, M.; Stancu, E.; Vancea, C., E-mail: scarlat.f@gmail.com [National Institute for Laser, Plasma and Radiation Physics - INFLPR, Bucharest (Romania)

    2011-07-01

    National Institute for Laser, Plasma and Radiation Physics (INFLPR) has constructed a High Energy Secondary Standard Dosimetry Laboratory SSDL-STARDOOR - for performing dosimetric calibrations according to ISO IEC SR/EN 17025:2005 standards. This is outfitted with UNIDOS Secondary Standard Dosimeter from PTW (Freiburg Physikalisch-Technische Werksttaten) calibrated at the PTB-Braunschweig (German Federal Institute of Physics and Metrology). A radiation beam of the quality of Q used by our laboratory as calibration source are provided by INFLPR 7 MeV electron beam linear accelerator mounted in our facility. (author)

  10. Informatische Modellbildung als Dimension einer künstlerisch-technisch konzipierten Medienbildung

    Directory of Open Access Journals (Sweden)

    Daniela Reimann

    2017-04-01

    Full Text Available Heute sind nicht nur diverse gestaltungsbezogene Disziplinen gefragt, sich aktiv mit der Digitalisierung von Information und ihren Potentialen und Nebenwirkungen für Bildungsprozesse auseinander zu setzen. In Deutschland haben sich Technikdidaktik und informatische Bildung getrennt von Medienpädagogik und Mediendidaktik entwickelt und wurden entsprechend unabhängig voneinander betrieben. Dies gilt auch für die Ästhetische Bildung, die informatisch-technische Inhalte kaum je curricular in die Auseinandersetzung mit digitaler Medienkultur integriert hat, schon gar nicht systematisch. Im diesem Artikel wird, ausgehend vom Stand der Forschung (zur Integration informatischer Inhalte in die Medienbildung und den identifizierten Grundproblemen der Medienbildung zwecks Kompensation der Defizite, ein auf Gestaltung basierter Ansatz präsentiert, kontextualisiert und diskutiert, der Technikverständnis in ein Konzept integrierter Medienbildung einbezieht, dies als Bildungsziel im Sinne eines ganzheitlichen Verständnisses von Welt begreift und daher disziplinüberschreitend angelegt ist. Der Ansatz geht über technokratische Vorstellungen einer Technikdidaktik hinaus, die Medientechnologien isoliert von lebensbedeutsamen, ästhetisch-künstlerisch gestalteten Kontexten betrachtet und vermittelt. Im didaktischen Konzept werden die Grundlagen informatischer Modellbildung als relevante Teilbereiche einer zeitgemässen, am Subjekt orientierten, gleichermassen ästhetisch-künstlerisch und technisch-informatisch geprägten Medienbildung aufgewiesen, ihre pädagogischen Vorläufer, Forschungsprojekte und Nachbardisziplinen benannt sowie Ausblicke für eine zeitgemässe Medienbildung gegeben.

  11. De bijdrage van Direct Manipulations Enviroments aan de ontwikkeling van technische geletterdheid in de basisschool

    NARCIS (Netherlands)

    Slangen, L.A.M.P.; Keulen, van Hanno; Jochems, W.M.G.; Keulen, van H.; Walma van der Molen, J.

    2009-01-01

    Om goed te kunnen participeren in de huidige maatschappij moeten mensen in zekere mate 'technische geletterd' zijn. Dat wil zeggen: ze moeten inzicht en enige interesse hebben in de rol en impact van wetenschap en techniek, een basisniveau aan (gebruiks)kennis en vaardigheid in de praktische

  12. Situation and development of solid state dosimetry from the PTB-point of view

    International Nuclear Information System (INIS)

    Hahn, D.; Nink, R.

    An outline is given of the legal situation concerning dosimetry in the field of radiation protection in the Federal Republic of Germany which is ruled by the German law of verification. The Physikalisch-Technische Bundesanstalt (PTB) therefore has worked out requirements for the type approval of TLD systems the main points of which are discussed briefly. A further progress of TLD - measuring methods and materials - seems desirable. Therefore, extended research with regard to preparation, TL mechanism and dosimetric properties is necessary. Examples of the activities in the solid state physics group of PTB - mainly concerning TLD an LiF - are given

  13. Practical experience in and improvements to aerosol sampling for trace analysis of airborne radionuclides in ground level air

    International Nuclear Information System (INIS)

    Arnold, D.; Jagielak, J.; Kolb, W.; Pietruszewski, A.; Wershofen, H.; Zarucki, R.

    1994-01-01

    In November 1989 the Polish government and the German government signed a bilateral agreement for scientific and technological co-operation. In the framework of this co-operation the Central Laboratory for Radiological Protection (CLRP), Warsaw, and the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, conducted a co-operation project in the field of monitoring the airborne radioactivity in ground level air. This progress report deals with the history of the project covering the period from July 1990 to December 1992, the scientific activities and their results. A proposal for future co-operation, which is planned for the near future, is made. (orig.)

  14. Neutron noise measurement technique in a coupled reactor

    International Nuclear Information System (INIS)

    Genoud, J.P.

    1976-01-01

    Describes work carried out on the swimming pool reactor at the Physikalisch-Technische Bundesanstalt at Braunschweig. The reactor has two multiplying zones, is light water moderated, with 90% enriched 235 U fuel. There is a D 2 0 reservoir between the two parts of the reactor. Signal/noise ratio obtained by means of ionisation chamber type neutron detectors of 10 -13 amp/u.f. sensitivity is of the order of 40 dB and band frequency 1.5 kHz. Spectral density of the interzone interaction energy was obtained by use of Fourier transforms, previously corrected by a Hanning window. (S.W.)

  15. Quality assurance for photovoltaic energy supply. Final report; Qualitaetssicherung von photovoltaischen Energieversorgungssystemen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bopp, G.; Gabler, H.; Hille, G.; Puls, G.; Rehm, M.; Sauer, U.; Schulz, M.; Schweizer-Ries, P.

    2000-07-01

    The availability of isolated PV systems was to be improved by an inspection agreement between operators, users and inspection organisations. The systems were to be inspected and serviced once a year. In all, 22 systems were inspected regularly between 1996 and 1999, and a failure statistics was drawn up on the basis of the records. On average, there were three failures per system and per year, one of which was caused by research activities. In a second detailed analysis after termination of the project, the failure rate had decreased to one every two years, i. e. a reduction by a factor of 6. [German] Ziel des Projektes war die Erhoehung der Betriebssicherheit und der Lebensdauer netzunabhaengiger Photovoltaikanlagen (Inselanlagen) durch Ermittlung und Reduzierung des Wartungsbedarfs sowie durch Komponentenoptimierung. Zu Projektbeginn war der technische und finanzielle Umfang von Wartungsarbeiten und somit den Betriebskosten dieser Anlagen nur sehr lueckenhaft bekannt und vorhersehbar. Um belastbare Erkenntnisse ueber den Wartungsbedarf und -kosten zu erhalten, fuehrten ortsansaessige Firmen mit Hilfe von Wartungshandbuechern auf Kosten der Betreiber in 22 ausgewaehlten Inselanlagen 4 Jahre lang 1 mal jaehrlich eine Fruehjahrskontrolle und eine Herbstinspektion durch. Das Fraunhofer ISE erstellte eine Fehlerstatistik, analysierte die Fehler und den Optimierungsbedarf. Durch die einmal jaehrliche Inspektion und durch den Einsatz optimierter Komponenten liess sich die anfaengliche Fehlerrate von 3 Fehlern pro Jahr und Anlage auf 1 Fehler innerhalb von 2 Jahren reduzieren. Die Anlagenfehler wurden ueberwiegend durch alterungsbedingte Bauteildefekte in Komponenten verursacht. Zusammen mit Herstellern wurde an Komponenten, wie Ladereglern und Wechselrichtern, Optimierungen durchgefuehrt. Die Optimierung der Anlagenbetriebsfuehrung erhoehte deutlich die Zufriedenheit des Nutzers und die Batterielebensdauer. Die Stromgestehungskosten in optimierten und regelmaessig

  16. Methods and quality assurance in environmental medicine. Formation of a RKI-Commission; Methoden und Qualitaetssicherung in der Umweltmedizin. Einrichtung einer Umweltmedizin-Kommission am RKI

    Energy Technology Data Exchange (ETDEWEB)

    Eis, D. [Bundesgesundheitsamt, Berlin (Germany). Robert-Koch-Institut

    2000-05-01

    An almost bewildering number of widely differing methods and techniques, often not validated, are being applied often inappropriately in the field of environmental medicine to answer questions regarding exposure assessment, diagnosis, treatment, counselling and prevention. Therefore, quality control within the field of environmental medicine is quite problematic. A primary goal of the newly formed RKI-Commission 'Methods and Quality Assurance in Environmental Medicine' is to form a panel of experts in the field, who evaluate the situation and generate consensus documents containing respective recommendations. By this the commission will contribute to standardization and agreement on appropriate methods, procedures and their correct application in the practice of environmental medicine. Hopefully it will also achieve a stronger, more consistent use of evidence-based-medicine and improve the quality of the structure, processes and results of research and practice in this field. The committee will initially deal with the issue of clinical environmental medicine, because here the largest problems in quality assurance are seen. In this context the commission will look at the problem areas of environmental-medical outpatient units and environmental clinics. The work of the commission will be supported by the newly formed Documentation and Evaluation Center for Methods in Environmental Medicine (Zentrale Erfassungs- und Bewertungsstelle fuer umweltmedizinische Methoden, ZEBUM) at the Robert Koch Institute. (orig.) [German] Im Rahmen der umweltmedizinischen Expositionserfassung, Diagnostik, Beratung, Therapie, Prophylaxe und Sanierung wird eine kaum mehr ueberschaubare Zahl unterschiedlichster, zum Teil nichtvalidierter Verfahren bei oftmals fragwuerdiger Indikation eingesetzt. Die umweltmedizinische Qualitaetssicherung (QS) ist damit zum Problem geworden. Ein Hauptanliegen der neu eingerichteten RKI-Kommission 'Methoden und Qualitaetssicherung in der

  17. Het effect van grondontsmetting en organische bemesting op het bouwplan in de Veenkolonien : een technisch-economische analyse

    NARCIS (Netherlands)

    Groenwold, J.G.

    1990-01-01

    In dit deelonderzoek van het project "Veranderingen in de Veenkoloniale Akkerbouw" wordt aandacht besteed aan de technische en economische gevolgen van vermindering van grondontsmetting in de aardappelteelt en de haalbaarheid van dierlijke mest en groenbemesters. Berekeningen zijn uitgevoerd met en

  18. 3D pilot. Eindrapport werkgroep technische specificaties voor de opbouw van de 3D IMGeo-CityGML

    NARCIS (Netherlands)

    Blaauboer, J.; Goos, J.; Ledoux, H.; Penninga, F.; Reuvers, M.; Stoter, J.E.; Vosselman, M.G.

    2012-01-01

    Deze notitie is de eindrapportage van Activiteit 3 van de zes 3D Pilot NL Fase II activiteiten: Technische specificaties bestekteksten voor de opbouw van IMGeo-CityGML. De 3D Pilot is een initiatief van het Kadaster, Geonovum, de Nederlandse Commissie voor Geodesie en het Ministerie van

  19. Involving private persons and corporations in the planning process according to paragraph 9b German nuclear law - practicability and limits

    International Nuclear Information System (INIS)

    Altmann, J.; Roesel, H.

    1978-01-01

    The 4th Amendment to the German Nuclear Law has procured the legal base for the disposal of radioactive waste in the German Federal Republic. The Nuclear Law states that the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig is responsible for the disposal of radioactive waste. The PTB can be assisted in its responsibilities by persons and institutions of private character. Involving private persons and corporations in the licensing process figures a legal problem, and there has been a seminar in the PTB discussing such problems. The present contribution gives a brief summary of the opinions stated by the various legal experts taking part in this seminar. (orig./HP) [de

  20. Quality management and reduction of processing time through automised preforming in the rotorblade manufacturing for wind turbines; Teilautomatisiertes preforming zur Qualitaetssicherung und Verkuerzung von Fertigungszeiten bei der Herstellung von Rotorblaettern von Windenergieanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Doersch, C.; Ohlendorf, J.H.; Gebauer, I.; Mueller, D.H. [Bremer Institut fuer Konstruktionstechnik, Universitaet Bremen (Germany); Weigel, L. [Abeking Rasmussen Rotec GmbH and Co. KG, Lemwerder (Germany)

    2007-11-15

    Rotor blades of wind turbines are mainly manufactured from fibre reinforced plastics. These materials show an excellent performance concering the ratio of stiffness and weight. Basically the composite material of rotor blades is made out of glass fibres and thermosetting material. But growing technological and economical requirements to rotor blades by off-shore-application, in particular through increasing rotor blade diameter, have to meet successful. Although reduction of processing time and increased quality of rotor blades play a major role. To achieve the increasing requirements of the rotor blade manufacturing the Bremen Institute for Engineering Design and the rotor blade manufacturer Abeking and Rasmussen Rotec GmbH are working together on the handling and manufacturing of textile preforms. Preforms are made out of stacked and bonded dry textile layers and deposited in the mould as one textile part. Preforming allows the parallel processing of some manufacturing steps. This shows great advantages in the production of fibre reinforced plastics because of the long curing time of the resin component. This parallel processing is required to reach the aim of decreased overall cycle time. This essay is focussing on the handling of textiles and the textile preforming. Summarised aspects of quality management and economics in textile preforming will be discussed with the aim of automising the preforming process. (Abstract Copyright [2007], Wiley Periodicals, Inc.) [German] Rotorblaetter von Windenergieanlagen werden aufgrund des guten Verhaeltnisses von Steifigkeit und Gewicht zu grossen Teilen aus Faserverbundwerkstoffen gefertigt. Dabei kommen hauptsaechlich Glasfasern (GF) als verstaerkendes Material sowie duroplastische Harze als Matrix zur Anwendung. Um die wachsenden Herausforderungen des Offshore-Einsatzes von Windenergieanlagen, insbesondere die steigende Rotorblattgroesse, technisch und wirtschaftlich erfolgreich bewaeltigen zu koennen, wird die

  1. The Physikalisch-Technische Bundesanstalt PTB (physical-technical Federal institution) - research institute and highest technical authority

    International Nuclear Information System (INIS)

    Klages, H.

    1976-01-01

    The PTB Braunschweig and Berlin is a Federal institution for the natural sciences and engineering and the highest technical authority for measurements. It is subject to the directions of the Federal Ministry for Economic Affairs. Its main tasks are representation, maintenance and development of physical units and, in connection with this, research, examinations, and granting permissions for calibration measuring equipment, as well as examinations of building types and permissions. The types of measuring equipment are represented. Many examinations are carried out on a voluntary basis. The advisory activities and the PTB's publications are also reported on. An organizational plan informs of the structure of the PTB. (orig.) [de

  2. Activity measurements of the radionuclide 109Cd for the PTB, Germany and the NIST, USA in the ongoing comparison BIPM.RI(II)-K1.Cd-109

    International Nuclear Information System (INIS)

    Ratel, G.; Michotte, C.; Janssen, H.; Kossert, K.; Lucas, L.; Karam, L.

    2005-01-01

    In 2004, the Physikalisch-Technische Bundesanstalt (PTB, Germany) and the National Institute of Standards and Technology (NIST, USA) each submitted one sample of known activity of 109 Cd to the International Reference System (SIR). The PTB result replaces their previous measurement of 1994 and the NIST result updates their 1986 CCRI(II) comparison result. The values of the activity submitted were about 15 MBq and 42 MBq. The new key comparison results have replaced the earlier values in the matrix of degrees of equivalence that now contains six results, identifier BIPM.RI(II)-K1.Cd-109, to which the remaining eleven results from the CCRI(II)-K2.Cd-109 held in 1986 are still linked. (authors)

  3. New techniques for cutting and decontamination for decommissioning of nuclear research reactors with consideration of cost reduction. Final report

    International Nuclear Information System (INIS)

    Bach, W.; Redeker, C.F.; Versemann, R.

    2003-06-01

    In decommissioning of research reactors, specific boundary conditions, such as special materials, nuclides, geometries, spatial circumstances exist. This project aims on the development and adaptation of progressive procedures for decommissioning tasks with respect to economical aspects (cost reduction). Explored are Laser Cutting techniques, especially the cutting of aluminium in atmosphere and under water, remote- and manually controlled; decontamination and removal of concrete and ceramics by a combined diodelaser / cryogenic carbon dioxide thermal shock treatment (dry ice blasting) as well as cutting with the water-abrasive-suspension-jet and the plasma beam. The project will lead to application in the decommissioning of PTB's FRMB (research reactor of Physikalisch Technische Bundesanstalt, Braunschweig, Germany). (orig.) [de

  4. Calibration of the precision high voltage dividers of the KATRIN experiment

    Energy Technology Data Exchange (ETDEWEB)

    Rest, Oliver [Institut fuer Kernphysik, Westfaelische Wilhelms-Universitaet Muenster (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The KATRIN (KArlsruhe TRItium Neutrino) experiment will measure the endpoint region of the tritium β decay spectrum to determine the neutrino mass with a sensitivity of 200 meV/c{sup 2}. To achieve this sub-eV sensitivity the energy of the decay electrons will be analyzed using a MAC-E type spectrometer. The retarding potential of the MAC-E-filter (up to -35 kV) has to be monitored with a relative precision of 3 . 10{sup -6}. For this purpose the potential will be measured directly via two custom made precision high voltage dividers, which were developed and constructed in cooperation with the Physikalisch-Technische Bundesanstalt Braunschweig. In order to determine the absolute values and the stability of the scale factors of the voltage dividers, regular calibration measurements are essential. Such measurements have been performed during the last years using several different methods. The poster gives an overview of the methods and results of the calibration of the precision high voltage dividers.

  5. Market segmentation end-consumers of domotica and technical control of behavior. Management summary; Marktsegmentatie eindgebruikers domotica en technische gedragssturing. Management samenvatting

    Energy Technology Data Exchange (ETDEWEB)

    Peeck, V.; Verheggen, P.P.; Schreurs, J.P.; Van Amersfoort, I.I. [Motivaction, Amsterdam (Netherlands)

    2001-07-01

    A qualitative and a quantitative study on the title subject were carried out. The quantitative study is based on the third measurement of the multi-client study in which attention is paid to attitudes (and use) of energy en the interest for domotica. The results are correlated with different types of communities. In the qualitative study attention is paid to motives to purchase domotica applications. [Dutch] Het programma DEMOS heeft in 2001 een aantal strategische studies uitgezet die elk een aspect van domotica en technische gedragsturing nader analyseren. In deze studie wordt specifiek gekeken naar de attitude van verschillende deelsegmenten consumenten inzake energie en de potentieale interesse voor domotica en technische gedragsturing, teneinde energiebesparing te realiseren. Motivaction heeft de studie, die bestaat uit een kwantitatieve en kwalitatieve fase, uitgevoerd. Voor het kwantitatieve deel is gebruik gemaakt van het multiclientonderzoek Socioconsult; gegevens daaruit op het gebied van energie en domotica zijn gekoppeld aan woonbelevingsgroepen. Vervolgens is een aantal domotica concepten voorgelegd aan en getoetst bij individuele consumenten in vier aparte groepsessies.

  6. Gasification of biomass - principles and technical alternatives; Vergasung von Biomassen - Prinzipien und technische Moeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Klose, E [Technische Univ. Bergakademie, Freiberg (Germany)

    1997-12-31

    The technical principles of gasification are outlined, and a number of biomass gasification processes are presented and compared with the coal gasification process. On the basis of the knowledge gained in coal gasification, it will be easy to carry out the development work still required on small-scale biomass gasification systems in cooperation with the gas users. (orig) [Deutsch] Das technische Prinzip derVergasung und verschiedene Verfahrensweisen bei der Vergasung von Biomasse werden vorgestellt und mit der Kohlevergasung verglichen. Auf der Grundlage der technischen Erkenntnisse bei der Kohlevergasung einschliesslich der vor- und nachgeschalteten Prozessstufen sind die noch notwendigen verfahrens- und apparatetechnischen Entwicklungsarbeiten fuer vorwiegend kleine Anlagen in Zusammenarbeit mit den Gasnutzern durchfuehrbar. (orig)

  7. Gasification of biomass - principles and technical alternatives; Vergasung von Biomassen - Prinzipien und technische Moeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Klose, E. [Technische Univ. Bergakademie, Freiberg (Germany)

    1996-12-31

    The technical principles of gasification are outlined, and a number of biomass gasification processes are presented and compared with the coal gasification process. On the basis of the knowledge gained in coal gasification, it will be easy to carry out the development work still required on small-scale biomass gasification systems in cooperation with the gas users. (orig) [Deutsch] Das technische Prinzip derVergasung und verschiedene Verfahrensweisen bei der Vergasung von Biomasse werden vorgestellt und mit der Kohlevergasung verglichen. Auf der Grundlage der technischen Erkenntnisse bei der Kohlevergasung einschliesslich der vor- und nachgeschalteten Prozessstufen sind die noch notwendigen verfahrens- und apparatetechnischen Entwicklungsarbeiten fuer vorwiegend kleine Anlagen in Zusammenarbeit mit den Gasnutzern durchfuehrbar. (orig)

  8. Development of a New Fundamental Measuring Technique for the Accurate Measurement of Gas Flowrates by Means of Laser Doppler Anemometry

    Science.gov (United States)

    Dopheide, D.; Taux, G.; Krey, E.-A.

    1990-01-01

    In the Physikalisch-Technische Bundesanstalt (PTB), a research test facility for the accurate measurement of gas (volume and mass) flowrates has been set up in the last few years on the basis of a laser Doppler anemometer (LDA) with a view to directly measuring gas flowrates with a relative uncertainty of only 0,1%. To achieve this, it was necessary to develop laser Doppler anemometry into a precision measuring technique and to carry out detailed investigations on stationary low-turbulence nozzle flow. The process-computer controlled test facility covers the flowrate range from 100 to 4000 m3/h (~0,03 - 1,0 m3/s), any flowrate being measured directly, immediately and without staggered arrangement of several flow meters. After the development was completed, several turbine-type gas meters were calibrated and international comparisons carried out. The article surveys the most significant aspects of the work and provides an outlook on future developments with regard to the miniaturization of optical flow and flowrate sensors for industrial applications.

  9. A superconducting wavelength shifter as primary radiometric source standard in the X-ray range

    Energy Technology Data Exchange (ETDEWEB)

    Klein, R. [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany)], E-mail: roman.klein@ptb.de; Brandt, G.; Cibik, L.; Gerlach, M.; Krumrey, M.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin (Germany); Scheer, M. [BESSY GmbH, Albert-Einstein-Strasse 15, 12489 Berlin (Germany)

    2007-10-11

    For more than 20 years, the Physikalisch-Technische Bundesanstalt (PTB) has been using the calculable radiation of bending magnets from the BESSY I and BESSY II electron storage rings in the visible, UV, vacuum-UV (VUV) and X-ray spectral range for radiometry, especially for the calibration of radiation sources and energy-dispersive detectors. Due to its-compared to bending magnets-higher magnetic field, wavelength shifters (WLS) have the potential to extend the usable spectral range for these applications to higher photon energies. Thus, the characteristic energies of BESSY II bending magnet radiation and a 6 T WLS radiation are 2.5 and 11.5 keV, respectively. Within the scope of this work, the properties of the synchrotron radiation from the 6 T WLS have been investigated and compared to theoretical predictions for photon energies up to 150 keV. Good agreement within the experimental uncertainty of several percent was found. Further improvements for a future radiometric use of WLS radiation with low uncertainties will be discussed.

  10. A superconducting wavelength shifter as primary radiometric source standard in the X-ray range

    International Nuclear Information System (INIS)

    Klein, R.; Brandt, G.; Cibik, L.; Gerlach, M.; Krumrey, M.; Mueller, P.; Ulm, G.; Scheer, M.

    2007-01-01

    For more than 20 years, the Physikalisch-Technische Bundesanstalt (PTB) has been using the calculable radiation of bending magnets from the BESSY I and BESSY II electron storage rings in the visible, UV, vacuum-UV (VUV) and X-ray spectral range for radiometry, especially for the calibration of radiation sources and energy-dispersive detectors. Due to its-compared to bending magnets-higher magnetic field, wavelength shifters (WLS) have the potential to extend the usable spectral range for these applications to higher photon energies. Thus, the characteristic energies of BESSY II bending magnet radiation and a 6 T WLS radiation are 2.5 and 11.5 keV, respectively. Within the scope of this work, the properties of the synchrotron radiation from the 6 T WLS have been investigated and compared to theoretical predictions for photon energies up to 150 keV. Good agreement within the experimental uncertainty of several percent was found. Further improvements for a future radiometric use of WLS radiation with low uncertainties will be discussed

  11. A superconducting wavelength shifter as primary radiometric source standard in the X-ray range

    Science.gov (United States)

    Klein, R.; Brandt, G.; Cibik, L.; Gerlach, M.; Krumrey, M.; Müller, P.; Ulm, G.; Scheer, M.

    2007-10-01

    For more than 20 years, the Physikalisch-Technische Bundesanstalt (PTB) has been using the calculable radiation of bending magnets from the BESSY I and BESSY II electron storage rings in the visible, UV, vacuum-UV (VUV) and X-ray spectral range for radiometry, especially for the calibration of radiation sources and energy-dispersive detectors. Due to its—compared to bending magnets—higher magnetic field, wavelength shifters (WLS) have the potential to extend the usable spectral range for these applications to higher photon energies. Thus, the characteristic energies of BESSY II bending magnet radiation and a 6 T WLS radiation are 2.5 and 11.5 keV, respectively. Within the scope of this work, the properties of the synchrotron radiation from the 6 T WLS have been investigated and compared to theoretical predictions for photon energies up to 150 keV. Good agreement within the experimental uncertainty of several percent was found. Further improvements for a future radiometric use of WLS radiation with low uncertainties will be discussed.

  12. Online imaging of initial DNA damages at the PTB microbeam

    International Nuclear Information System (INIS)

    Giesen, U.; Langner, F.; Mielke, C.; Mosconi, M.; Dirks, W. G.

    2011-01-01

    In an inter-disciplinary collaboration of Physikalisch-Technische Bundesanstalt (PTB), German Collection of Microorganisms and Cell Cultures (DSMZ) and Heinrich-Heine Univ., live-cell imaging has been established at the charged-particle microbeam facility of PTB. Candidate genes participating in DNA strand-break repair pathways such as PARP-1, MRE11, MSH2, MDC1 and p53BP1 have been modified to generate fluorescent fusion proteins. Using multi-cistronic expression vectors, stable genomic integration was achieved in HT-1080 fibroblasts. The aim of this study is to characterise and use these highly reliable cell lines for studying initial steps of DNA damage responses and kinetics of repair after microbeam irradiation with high- and low-linear energy transfer (LET) particles in living cells at physiological conditions. (authors)

  13. Gas detectors for x-ray lasers

    International Nuclear Information System (INIS)

    Tiedtke, K.; Feldhaus, J.; Hahn, U.; Jastrow, U.; Nunez, T.; Tschentscher, T.; Bobashev, S. V.; Sorokin, A. A.; Hastings, J. B.; Moeller, S.; Cibik, L.; Gottwald, A.; Hoehl, A.; Kroth, U.; Krumrey, M.; Schoeppe, H.; Ulm, G.; Richter, M.

    2008-01-01

    We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 μm for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford

  14. Gas detectors for x-ray lasers

    Science.gov (United States)

    Tiedtke, K.; Feldhaus, J.; Hahn, U.; Jastrow, U.; Nunez, T.; Tschentscher, T.; Bobashev, S. V.; Sorokin, A. A.; Hastings, J. B.; Möller, S.; Cibik, L.; Gottwald, A.; Hoehl, A.; Kroth, U.; Krumrey, M.; Schöppe, H.; Ulm, G.; Richter, M.

    2008-05-01

    We have developed different types of photodetectors that are based on the photoionization of a gas at a low target density. The almost transparent devices were optimized and tested for online photon diagnostics at current and future x-ray free-electron laser facilities on a shot-to-shot basis with a temporal resolution of better than 100 ns. Characterization and calibration measurements were performed in the laboratory of the Physikalisch-Technische Bundesanstalt at the electron storage ring BESSY II in Berlin. As a result, measurement uncertainties of better than 10% for the photon-pulse energy and below 20 μm for the photon-beam position were achieved at the Free-electron LASer in Hamburg (FLASH). An upgrade for the detection of hard x-rays was tested at the Sub-Picosecond Photon Source in Stanford.

  15. Fluence measurement at the neutron time of flight experiment at CERN

    CERN Document Server

    Weiss, Christina; Jericha, Erwin

    At the neutron time of flight facility n_TOF at CERN a new spallation target was installed in 2008. In 2008 and 2009 the commissioning of the new target took place. During the summer 2009 a fission chamber of the Physikalisch Technische Bundesanstalt (PTB) Braunschweig was used for the neutron fluence measurement. The evaluation of the data recorded with this detector is the primary topic of this thesis. Additionally a neutron transmission experiment with air has been performed at the TRIGA Mark II reactor of the Atomic Institute of the Austrian Universities (ATI). The experiment was implemented to clarify a question about the scattering cross section of molecular gas which could not be answered clearly via the literature. This problem came up during the evaluations for n_TOF.

  16. Alpha-induced reactions on selenium between 11 and 15 MeV

    Science.gov (United States)

    Fiebiger, Stefan; Slavkovská, Zuzana; Giesen, Ulrich; Göbel, Kathrin; Heftrich, Tanja; Heiske, Annett; Reifarth, René; Schmidt, Stefan; Sonnabend, Kerstin; Thomas, Benedikt; Weigand, Mario

    2017-07-01

    The production of 77,79,85,85m Kr and 77Br via the reaction Se(α ,x) was investigated between {E}α =11 and 15 MeV using the activation technique. The irradiation of natural selenium targets on aluminum backings was conducted at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. The spectroscopic analysis of the reaction products was performed using a high-purity germanium detector located at PTB and a low energy photon spectrometer detector at the Goethe University Frankfurt, Germany. Thick-target yields were determined. The corresponding energy-dependent production cross sections of 77,79,85,85m Kr and 77Br were calculated from the thick-target yields. Good agreement between experimental data and theoretical predictions using the TALYS-1.6 code was found.

  17. Late effects of mining operations. Technical and legal aspects. Conference; Spaetfolgen des Bergbaus. Technische und rechtliche Fragen. Tagung

    Energy Technology Data Exchange (ETDEWEB)

    Liese, F. (comp.)

    2000-07-01

    The problem of late effects of mining was reviewed. Solutions were found which may be interesting to other countries as well. [German] Spaetfolgen des Bergbaus - ein sowohl technisch als auch rechtlich hochbrisantes Phaenomen: Bergwerksstandorte wurden aufgegeben, andere Oberflaechennutzungsformen machten sich auf diesem Gelaende breit. Dort koennen auch noch lange nach Einstellung des Bergbaus Schaeden eintreten. Welche technischen Ursachen haben sie? Diese Problematik wird anhand der Situation in Deutschland untersucht. Die Loesungsansaetze koennen aber auch fuer andere Laender fruchtbar gemacht werden. (orig.)

  18. Brachytherapy source calibration, reviews, and consistency of 192Ir high-dose rate afterloading sources supplied over the period of 10 years: a retrospective analysis

    International Nuclear Information System (INIS)

    Nagappan, Balasubramanian; Kumar, Yogesh; Patel, Narayan P.; Dhull, Anil Kumar; Kaushal, Vivek

    2015-01-01

    Measurement and verification of strength of monomodal high-dose rate (mHDR) 192 Ir source supplied by the vendor is a major part of quality assurance program. Reference air kerma rate (RAKR) or air kerma strength (AKS) is the recommended quantity to specify the strength of gamma emitting brachytherapy sources. Physicist in our institution performed the source calibration as soon as each 192 Ir new source was loaded on the mHDR afterloading machine. The AKS accurately measured using a physikalisch technische werkstatten (PTW) re-entrant chamber-electrometer system in a scatter-free geometry was used to compute the air kerma rate (AKR) at one-meter distance in the air. To ensure accurate dose delivery to brachytherapy patients, measured AKS or RAKR should be entered correctly in both HDR treatment console station (TCS) as well as treatment planning system (TPS) associated with it. The clinical outcome mainly depends not only on the accuracy of the source strength measurement in the hospital but also on the correct source strength entered into both TCS and TPS software. A retrospective study on 22 mHDR V2 sources supplied by the vendor for the period of 10 years was taken up to access the accuracy of source strength supplied to the Radiotherapy department. The results are analyzed and reported. The accuracy in measured RAKR of all 22 sources supplied by vendor was well within the tolerance limits set by the national regulatory body and international recommendations. The deviations observed between measured RAKR versus manufacturer's quoted RAKR were in the range from -1.71% to +1.15%. In conclusion, the measured RAKR have good agreement with vendor quoted RAKR values. (author)

  19. Final report on bilateral comparison EURAMET.M.T-S3: Torque wrenches (10 N m - 1 kN m)

    Science.gov (United States)

    Röske, Dirk; Medina, Nieves

    2011-01-01

    A bilateral comparison from 10 N m up to 1000 N m has been carried out between Physikalisch-Technische Bundesanstalt (PTB) and Centro Español de Metrología (CEM) for reference torque wrenches calibrated according to DKD-R 3-7. The transfer standards have been two reference torque wrenches, 10 N m and 1000 N m respectively, that have been measured between November and December 2010. The results presented here demonstrate the metrological equivalence, within the quoted uncertainties, of both participant laboratories. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Measuring and interpreting X-ray fluorescence from planetary surfaces.

    Science.gov (United States)

    Owens, Alan; Beckhoff, Burkhard; Fraser, George; Kolbe, Michael; Krumrey, Michael; Mantero, Alfonso; Mantler, Michael; Peacock, Anthony; Pia, Maria-Grazia; Pullan, Derek; Schneider, Uwe G; Ulm, Gerhard

    2008-11-15

    As part of a comprehensive study of X-ray emission from planetary surfaces and in particular the planet Mercury, we have measured fluorescent radiation from a number of planetary analog rock samples using monochromatized synchrotron radiation provided by the BESSY II electron storage ring. The experiments were carried out using a purpose built X-ray fluorescence (XRF) spectrometer chamber developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The XRF instrumentation is absolutely calibrated and allows for reference-free quantitation of rock sample composition, taking into account secondary photon- and electron-induced enhancement effects. The fluorescence data, in turn, have been used to validate a planetary fluorescence simulation tool based on the GEANT4 transport code. This simulation can be used as a mission analysis tool to predict the time-dependent orbital XRF spectral distributions from planetary surfaces throughout the mapping phase.

  1. Experiences with a technically oriented plant management system; Erfahrungen mit einem technisch orientierten Betriebs-Management-System

    Energy Technology Data Exchange (ETDEWEB)

    Haffmann, E. [GiS Gesellschaft fuer integrierte Systemplanung mbH, Erlangen (Germany)

    2000-07-01

    This contribution first deals with the duality of mercantile and technical plant management systems. The following aspects are considered: reasons for and history of this duality; different approaches taken by mercantile and technical plant management systems; differences in the standardisability of mercantile and technical tasks. Dissolution of the duality through coordinated interplay. The author then goes on to explain the most important components of technically oriented maintenance management. These include the collection of technical plant data (with maintenance-relevant data and relations); the establishment of recurring tasks, the commissioning method (involving occupational safety, packaging and evaluation), compilation of manuals, reporting and accompanying plant documentation. The following tools are useful for DP-assisted maintenance: depiction of organisational and operational structures (authorisation system + IBFS application); workflow systems; modelling (data and object models); navigators; form and dialogue generators; integration of external software (project planning, CAD and Office); interface to mercantile systems. Some highlights of the C/S-IBFS were demonstrated in practice at the symposium. [German] Das Referat behandelt zunaechst die Dualitaet von kaufmaennischen und technischen Betriebs-Management-Systemen anhand folgender Aspekte: - Gruende und Historie dieser Dualitaet, - unterschiedliche Loesungsansaetze von kaufmaennischen und technischen Betriebs-Management-Systemen, - unterschiedliche Standardisierbarkeit von kaufmaennischen und technischen Aufgabenstellungen, - Aufloesung der Dualitaet durch koordniertes Zusammenwirken. Sodann werden wichtige Bausteine eines technisch orientierten Instandhaltungs-Managements erlaeutert. Dazu gehoeren die technische Anlagenerfassung (mit instandhaltungsrelevanten Daten und Relationen), die Einrichtung wiederkehrender Aufgaben, das Arbeitsauftragsverfahren (mit Arbeitssicherheit, Paketierung und

  2. Development and production of a multilayer-coated x-ray reflecting stack for the Athena mission

    Science.gov (United States)

    Massahi, S.; Ferreira, D. D. M.; Christensen, F. E.; Shortt, B.; Girou, D. A.; Collon, M.; Landgraf, B.; Barriere, N.; Krumrey, M.; Cibik, L.; Schreiber, S.

    2016-07-01

    The Advanced Telescope for High-Energy Astrophysics, Athena, selected as the European Space Agency's second large-mission, is based on the novel Silicon Pore Optics X-ray mirror technology. DTU Space has been working for several years on the development of multilayer coatings on the Silicon Pore Optics in an effort to optimize the throughput of the Athena optics. A linearly graded Ir/B4C multilayer has been deposited on the mirrors, via the direct current magnetron sputtering technique, at DTU Space. This specific multilayer, has through simulations, been demonstrated to produce the highest reflectivity at 6 keV, which is a goal for the scientific objectives of the mission. A critical aspect of the coating process concerns the use of photolithography techniques upon which we will present the most recent developments in particular related to the cleanliness of the plates. Experiments regarding the lift-off and stacking of the mirrors have been performed and the results obtained will be presented. Furthermore, characterization of the deposited thin-films was performed with X-ray reflectometry at DTU Space and in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II.

  3. Results of the dosimetry intercomparison

    International Nuclear Information System (INIS)

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  4. Cross sections for ionization of tetrahydrofuran by protons at energies between 300 and 3000 keV

    Science.gov (United States)

    Wang, Mingjie; Rudek, Benedikt; Bennett, Daniel; de Vera, Pablo; Bug, Marion; Buhr, Ticia; Baek, Woon Yong; Hilgers, Gerhard; Rabus, Hans

    2016-05-01

    Double-differential cross sections for ionization of tetrahydrofuran by protons with energies from 300 to 3000 keV were measured at the Physikalisch-Technische Bundesanstalt ion accelerator facility. The electrons emitted at angles between 15∘ and 150∘ relative to the ion-beam direction were detected with an electrostatic hemispherical electron spectrometer. Single-differential and total ionization cross sections have been derived by integration. The experimental results are compared to the semiempirical Hansen-Kocbach-Stolterfoht model as well as to the recently reported method based on the dielectric formalism. The comparison to the latter showed good agreement with experimental data in a broad range of emission angles and energies of secondary electrons. The scaling property of ionization cross sections for tetrahydrofuran was also investigated. Compared to molecules of different size, the ionization cross sections of tetrahydrofuran were found to scale with the number of valence electrons at large impact parameters.

  5. Postirradiation effects in alanine dosimeter probes of two different suppliers

    International Nuclear Information System (INIS)

    Anton, Mathias

    2008-01-01

    The measurand relevant for the dosimetry for radiation therapy is the absorbed dose to water, D W . The Physikalisch-Technische Bundesanstalt (PTB) is establishing a secondary standard for D W for high-energy photon and electron radiation based on electron spin resonance (ESR) of the amino acid alanine. For practical applications, like, for example, intercomparison measurements using the ESR/alanine dosimetry system, the temporal evolution of the ESR signal of irradiated probes is an important issue. This postirradiation behaviour is investigated for alanine pellets of two different suppliers for different storage conditions. The influence of the storage conditions on the temporal evolution may be dependent on the type of probes used. The measurement and analysis method developed at the PTB is able to circumvent the apparent difficulties in the case of alanine/paraffin probes. Care has to be taken in case this method cannot be applied

  6. High-frame rate imaging of two-phase flow in a thin rectangular channel using fast neutrons.

    Science.gov (United States)

    Zboray, R; Mor, I; Dangendorf, V; Stark, M; Tittelmeier, K; Cortesi, M; Adams, R

    2014-08-01

    We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 ms exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and mean bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Fitting methods for constructing energy-dependent efficiency curves and their application to ionization chamber measurements

    International Nuclear Information System (INIS)

    Svec, A.; Schrader, H.

    2002-01-01

    An ionization chamber without and with an iron liner (absorber) was calibrated by a set of radionuclide activity standards of the Physikalisch-Technische Bundesanstalt (PTB). The ionization chamber is used as a secondary standard measuring system for activity at the Slovak Institute of Metrology (SMU). Energy-dependent photon-efficiency curves were established for the ionization chamber in defined measurement geometry without and with the liner, and radionuclide efficiencies were calculated. Programmed calculation with an analytical efficiency function and a nonlinear regression algorithm of Microsoft (MS) Excel for fitting was used. Efficiencies from bremsstrahlung of pure beta-particle emitters were calibrated achieving a 10% accuracy level. Such efficiency components are added to obtain the total radionuclide efficiency of photon emitters after beta decay. The method yields differences of experimental and calculated radionuclide efficiencies for most of the photon-emitting radionuclides in the order of a few percent

  8. Experimental facilities for calibrations at the dosimetry facility of group 6.5 'Neutron dosimetry' at the Physikalisch-Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Strzelczyk, H.

    1986-07-01

    The mechanical and electrical layout of the ''Dosimetriemessplatz'', a low scattering target area at the accelerator facility is described. Monoenergetic neutrons are generated at the irradiation facility for the research on neutron detectors and dosimeters for radiation protection. The report is aimed to inform dosimetry in particular for those guest's coming from other laboratories. For that purpose a detailed description is given of the mechanical construction, of cable connections and of the monitor system. The feasibitity of data transfer from the system at the target position to the user's system and the mode of acceptance of external data are explained. (orig./HP) [de

  9. Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

    Science.gov (United States)

    Zuber, Ralf; Sperfeld, Peter; Riechelmann, Stefan; Nevas, Saulius; Sildoja, Meelis; Seckmeyer, Gunther

    2018-04-01

    A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5 % from most other instruments in most situations and not exceeding 3 % from established TOC measurement systems such as Dobson or Brewer.

  10. International intercomparison of fluence of fast neutrons using 115In(n,γ) activation

    International Nuclear Information System (INIS)

    Lesiecki, H.; Cosack, M.

    1985-07-01

    The Physikalisch-Technische Bundesanstalt (PTB) has participated in an international intercomparison of fluence measurements of fast neutrons. This was organized under the auspices of the ''Comite Consultatif pour les Etalons de Mesure des Rayonnements Ionisants (CCEMRI)'', Sect. 3 (Mesures Neutronique). The National Physical Laboratory (NPL), Teddington, UK volunteered to assume responsibility for the experimental realization and final evaluation. This report deals with the measurements performed at the PTB for the neutron fluence intercomparison at neutron energies of Esub(n) = 144 keV and 570 keV which was based on the 115 In(n,γ) 116 Insup(m) reaction. The count rate of a 4πβ-counter which had to be used to determine the activation of the In sample was to be compared with the neutron fluence by which the sample was irradiated. A description of the neutron production, the fluence determination, the 4πβ-counting, and the evaluation of the results will be given. (orig.) [de

  11. The Electron Cyclotron Resonance Light Source Assembly of PTB - ELISA

    CERN Document Server

    Gruebling, P; Ulm, G

    1999-01-01

    In the radiometry laboratory of the Physikalisch-Technische,Bundesanstalt at the Berlin electron storage ring BESSY I, radiation sources for radiometric applications in industry and basic research in the vacuum ultraviolet (VUV) spectral range are developed, characterized and calibrated. Established sources such as deuterium lamps, Penning and hollow cathode discharge sources have limited spectral ranges and in particular their stability and life time suffers from the erosion of the cathode material. To overcome these limitations we have developed a radiation source based on the principle of the electron cyclotron resonance ion source. ELISA is a 10 GHz monomode source with a compact design featuring a tunable cavity and axially positionable permanent magnets. The radiation emission of the source can be detected simultaneously in the VUV and X-ray spectral range via a toroidal grating monochromator and a Si(Li)-detector. The special design of the source allows spectroscopic investigations of the plasma in dep...

  12. Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response.

    Science.gov (United States)

    Troussel, Ph; Villette, B; Emprin, B; Oudot, G; Tassin, V; Bridou, F; Delmotte, F; Krumrey, M

    2014-01-01

    CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

  13. Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer

    Directory of Open Access Journals (Sweden)

    C. Monte

    2014-01-01

    Atmosphere is an airborne, imaging, infrared Fourier transform spectrometer that applies the limb-imaging technique to perform trace gas and temperature measurements in the Earth's atmosphere with three-dimensional resolution. To ensure the traceability of these measurements to the International Temperature Scale and thereby to an absolute radiance scale, GLORIA carries an on-board calibration system. Basically, it consists of two identical large-area and high-emissivity infrared radiators, which can be continuously and independently operated at two adjustable temperatures in a range from −50 °C to 0 °C during flight. Here we describe the radiometric and thermometric characterization and calibration of the in-flight calibration system at the Reduced Background Calibration Facility of the Physikalisch-Technische Bundesanstalt. This was performed with a standard uncertainty of less than 110 mK. Extensive investigations of the system concerning its absolute radiation temperature and spectral radiance, its temperature homogeneity and its short- and long-term stability are discussed. The traceability chain of these measurements is presented.

  14. Performance of ionization chambers in X radiation beams, radioprotection level

    International Nuclear Information System (INIS)

    Bessa, Ana C.M.; Potiens, Maria da Penha A.; Caldas, Linda V.E.

    2005-01-01

    Narrow beams, radioprotection level, were implanted in an X ray system, based on ISO 4037-1, as recommended by IAEA (SRS 16). Energy dependency tests were carried out and short-term stability in ionization chambers for use in radiation protection of trademark Physikalisch-Technische Werkstaetten (PTW), 32002 and 23361 models. The ionization chambers were studied with regard to short-term stability within the program of quality control of the laboratory, with a 90 Sr + 90 Y. The results of the short-term stability test were compared with the recommendations of IEC 60731, respect to dosemeters used in radiotherapy, since this standard presents the more restrictive limits with regard to the behaviour of ionization chambers. All cameras showed results within the limits recommended by this standard. With respect to the energy dependency of the response, the model Chamber 32002 presented a maximum dependence of only 2.7%, and the model Chamber 23361, 4.5%

  15. Environmental radiation monitoring of nuclear sites by thermoluminescent dosimeters (TLD)

    International Nuclear Information System (INIS)

    Duftschmid, K.E.; Strachotinsky, Ch.

    1978-04-01

    The measurement of environmental radiation doses around nuclear facilities requires the detection of few mrem/year. The properties of the automatic TLD-system Harshaw Mod. 2271 for such measurements have been evaluated under practical conditions and optimized techniques derived. The automatic TLD-system is based on LiF dosimeter cards with two crystals providing gamma and beta dose values. Limit of detection defined as three standard deviations of residuel dose is 1,2 mR. Automatic readout combined with electronic data evaluation are especially useful for large monitoring networks. Practical intercomparisons of this dosimeter with bulb-type CaF 2 detectors have been performed showing good agreement of both detector. Although bulb-dosimeters proved to be extremely sensitive with a limit of detection at 0,012 mR which makes them very suitable for very short exposure times, the automatic LiF system is superior in regards of man power requirement if monthly monitoring periods are sufficient. The system has been tested in practice during two international intercomparisons performed by the US Department of Energy - Health and Safety Laboratory New York and the Physikalisch Technische Bundesanstalt Braunschweig, Germany, showing excellent agreement. Furthermore a routine monitoring network consisting of 12 measurement positions around the Research Center Seibersdorf has been operated with this technique since more than two years. (author)

  16. Techno-economic accompanying research the national competition ''Bioenergy Regions''. Final report funding measure 2009-2012; Technisch-oekonomische Begleitforschung des Bundeswettbewerbes ''Bioenergie-Regionen''. Endbericht Foerdermassnahme 2009-2012

    Energy Technology Data Exchange (ETDEWEB)

    Bohnet, Sebastian; Haak, Falko; Gawor, Marek [DBFZ Deutsches Biomasseforschungszentrum gemeinnuetzige GmbH, Leipzig (Germany); Thraen, Daniela [DBFZ Deutsches Biomasseforschungszentrum gemeinnuetzige GmbH, Leipzig (Germany); Helmholtz-Zentrum fuer Umweltforschung (UFZ), Leipzig (Germany)

    2015-07-01

    This final report describes the results of the techno-economic accompanying research of the competition of bioenergy regions. The competition was realized as a three-year funding project of the Federal Ministry of Food, Agriculture and Consumer Protection (BMELV), wherein the DBFZ analyzed the bioenergy development in the project regions and effects for regional development. The aim of the techno-economic accompanying research was to evaluate the project regions regarding the use of bioenergy. To this end, the bioenergy plants and supply chains of bioenergy as well as the raw materials used were the focus of investigations. Hereby the comparison between the regions and classification of the national average should be made possible. It was also necessary to be able to make statements about the climate protection contribution of funding the project. Not least the DBFZ supported the office of competition and the regions in answering technical-economic issues. The report is divided into a theoretical part A and the result Part B. After a summary of the results (chapter 1) and a brief overview of important and higher-level indicators (Chapter 2) the background and objectives of the competition are in Part A, first presented (Chapter 3). This is followed by Chapter 4 of the explanation of the methodological approach. Part B contains the results of the accompanying research project. The individual chapters are based respectively on the specific questions or thematic blocks of techno-economic accompanying research (Section 5-8). The final chapter 9 takes a brief look at the second funding phase from 2012 to 2015. [German] Der vorliegende Endbericht beschreibt die Ergebnisse der technisch-oekonomischen Begleitforschung zum Wettbewerb Bioenergie-Regionen. Der Wettbewerb wurde als dreijaehriges Foerdervorhaben des Bundesministeriums fuer Ernaehrung, Landwirtschaft und Verbraucherschutz (BMELV) realisiert, bei dem das DBFZ die Bioenergieentwicklung in den Projektregionen sowie

  17. Photon contributions from the 252Cf and 241Am–Be neutron sources at the PSI Calibration Laboratory

    International Nuclear Information System (INIS)

    Hoedlmoser, H.; Boschung, M.; Meier, K.; Stadtmann, H.; Hranitzky, C.; Figel, M.; Mayer, S.

    2012-01-01

    At the accredited PSI Calibration Laboratory neutron reference fields traceable to the national standards of the Physikalisch-Technische Bundesanstalt (PTB) in Germany are available for the calibration of ambient and personal dose equivalent (rate) meters and passive dosimeters. The photon contribution to the ambient dose equivalent in the neutron fields of the 252 Cf and 241 Am–Be sources was measured using various photon dose rate meters and active and passive dosimeters. Measuring photons from a neutron source usually involves considerable uncertainties due to the presence of neutron induced photons in the room, due to a non-zero neutron sensitivity of the photon detector, and last but not least due to the energy response of the photon detectors. Therefore eight independent detectors and methods were used to obtain a reliable estimate for the photon contribution of the two sources as an average of the individual methods. For the 241 Am–Be source a photon contribution of approximately 4.9% was determined and for the 252 Cf source a contribution of 3.6%.

  18. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  19. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  20. Phasenübergänge

    Science.gov (United States)

    Heintze, Joachim

    Bisher haben wir nur das thermische Verhalten von Stoffen einheitlicher Konsistenz diskutiert. Eines der auffälligsten Phänomene in der Physik der Wärme ist aber, dass ein Stoff in verschiedenen Aggregatzuständen vorliegen kann: fest, flüssig oder gasförmig, und dass durch Wärmezufuhr und -abfuhr Übergänge zwischen diesen verschiedenen Phasen bewirkt werden. Zunächst werden wir die Phasenübergänge flüssig-gasförmig und fest-gasförmig ausführlich diskutieren. Dann zeigen wir, dass der Phasenübergang fest-flüssig auf ganz ähnliche Weise beschrieben werden kann. Eine zusammenfassende Darstellung der Phasenübergänge ist in der Form von Zustandsdiagrammen möglich. Die Untersuchung solcher Diagramme führt auf das interessante Phänomen des kritischen Punktes. Am Schluss des Kapitels betrachten wir Phasenübergänge in Zweistoffsystemen. Sie weisen einige Eigenschaften auf, die nicht nur merkwürdig und physikalisch interessant, sondern vor allem auch technisch von Bedeutung sind.

  1. Comparisons of the standards for air kerma of the PTB and the BIPM for 60Co and 137Cs gamma radiation

    International Nuclear Information System (INIS)

    Allisy-Roberts, P.J.; Burns, D.T.; Buermann, L.; Kramer, H.M.

    2005-11-01

    Direct comparisons of the standards for air kerma of the Physikalisch-Technische Bundesanstalt (PTB, Germany) and of the Bureau International des Poids et Mesures (BIPM) were carried out in the 60 Co and 137 Cs radiation beams of the BIPM in 2000. The results, expressed as ratios of the PTB and the BIPM standards for air kerma, indicate a relative difference in 60 Co of 9.9 x 10 -3 with a combined standard uncertainty of 1.8 x 10 -3 , and in 137 Cs of 6.4 x 10 -3 with a combined standard uncertainty of 2.8 x 10 -3 . The earlier comparisons in 60 Co γ rays made in 1971 (direct) and 1989 (indirect) resulted in an agreement of the two standards within 2 x 10 -3 . The differences obtained now are due to the application of new correction factors for wall effects and point source non-uniformity of the beam, k wall and k pn , for the PTB standards, which were calculated using Monte Carlo methods. (authors)

  2. Determination of the activity of the uranium isotopes U-234, U-235 and U-238 in environmental samples by alpha spectrometry

    International Nuclear Information System (INIS)

    Kromphorn, G.

    1996-02-01

    Different materials containing urandium are regularly investigated in the Laboratory for Environmental Radioactivity of the Physikalisch-Technische Bundesanstalt (PTB) with respect to the activity of the uranium isotopes ( 234 U, 235 U, and 238 U). Moreover for reasons of quality assurance, the PTB takes part in international comparisons where also uranium contents are to be determined in environmental samples and in the framework of which reference materials can be certified. Finally in national comparisons the PTB has the task to determine values of the specific activity for the different isotopes which can play the role of nominal (orientation) values. The single steps of uranium analyses are described after a compilation of the most important data of the uranium isotopes contained in natural uranium: The use of 232 U as tracer, the chemical separation analytics, the production of α-sources and the measuring methods. Analyses of a soil sample and a waste water sample with respect to their specific uranium activity have been chosen as examples of a practical application. (orig.) [de

  3. Towards a determination of the absorbed dose to water in water for low-energy photon-emitting brachytherapy seeds

    International Nuclear Information System (INIS)

    Schneider, T.; Lange, B.; Selbach, H.J.

    2007-01-01

    An accurate determination of the dose produced by brachytherapy seeds emitting low-energy photons is an important component of the radiotherapeutic process. As yet, the output of these seeds has usually been specified in terms of the air kerma rate. The desired quantity in radiation therapy is, however, the absorbed dose to water inside a water phantom, for which primary standards are not available. For this reason, developments are under way in the Physikalisch - Technische Bundesanstalt to establish a primary standard to determine the absorbed dose to water within a phantom. As a fundamental step towards this aim, a method will be introduced in this publication to determine the water kerma inside a graphite phantom housing an extrapolation chamber. Experimental results will be presented and compared with water kerma values obtained from air kerma measurements in free air and applying a conversion factor to water kerma for the conditions of the experiment. First estimates indicate that the relative uncertainty is of the order of 1% (k 1). (authors)

  4. Type testing of devices with inserted radioactive sources

    International Nuclear Information System (INIS)

    Rolle, A.; Droste, B.; Dombrowski, H.

    2006-01-01

    In Germany devices with inserted radioactive sources can get a type approval if they comply with specific requirements. Whoever operates a device whose type has been approved in accordance with the German Radiation Protection Ordinance does not need an individual authorization. Such type approvals for free use are granted by the Federal Office for Radiation Protection (B.f.S.) on the basis of type testing performed by the Physikalisch-Technische Bundesanstalt (P.T.B.), the national metrology institute, and the Bundesanstalt fur Materialforschung und -prufung (B.A.M.), the Federal Institute for Materials Research and Testing. Main aspects of the assessment are the activity of the radioactive sources, the dose equivalent rate near the devices, the tamper-proofness and leak-tightness of the sources and the safety of the construction of the devices. With the new Radiation Protection Ordinance in 2001, more stringent requirements for a type approval were established. Experiences with the new regulations and the relevant assessment criteria applied by P.T.B. and B.A.M. will be presented. (authors)

  5. The new remcounter LB6411: Measurement of neutron ambient dose equivalent H*(10) according to ICRP60 with high sensitivity

    International Nuclear Information System (INIS)

    Klett, A.; Burgkhardt, B.

    1996-01-01

    Since the International Commission on Radiological Protection has issued in publication ICRP60 new recommendations on radiation protection quantities, in neutron monitoring there is now increasing Interest in commercially available instruments optimized and calibrated for the measurement of ambient dose equivalent H*(10). Therefore within a joint cooperation between the Research Center Karlsruhe and EG ampersand G Berthold the neutron-dose-rate meter LB6411 was newly developed. The detector system with integrated electronics has a 3 He proportional counter tube centered in a moderating sphere. The response between thermal energies and 20 MeV was optimized with the help of extensive MCNP Monte-Carlo calculations. The instrument has extremely high sensitivity of approximately 3 counts per nSv and can be used both as a portable or as a stationary neutron monitor. Fluence responses and angular dependencies had been measured in monoenergetic neutron beams provided by the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. The ambient dose equivalent response of the LB6411 is reported over the whole energy range

  6. Small-angle X-ray scattering (SAXS) for metrological size determination of nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Gleber, Gudrun; Krumrey, Michael; Cibik, Levent; Marggraf, Stefanie; Mueller, Peter [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Hoell, Armin [Helmholtz-Zentrum Berlin, Albert-Einstein-Str. 15, 12489 Berlin (Germany)

    2011-07-01

    To measure the size of nanoparticles, different measurement methods are available but their results are often not compatible. In the framework of an European metrology project we use Small-Angle X-ray Scattering (SAXS) to determine the size and size distribution of nanoparticles in aqueous solution, where the special challange is the traceability of the results. The experiments were performed at the Four-Crystal Monochromator (FCM) beamline in the laboratory of Physikalisch-Technische Bundesanstalt (PTB) at BESSY II using the SAXS setup of the Helmholtz-Zentrum Berlin (HZB). We measured different particles made of PMMA and gold in a diameter range of 200 nm down to about 10 nm. The aspects of traceability can be classified in two parts: the first is the experimental part with the uncertainties of distances, angles, and wavelength, the second is the part of analysis, with the uncertainty of the choice of the model used for fitting the data. In this talk we want to show the degree of uncertainty, which we reached in this work yet.

  7. Study of glass hydrometer calibration by hydrostatic weighting

    Science.gov (United States)

    Chen, Chaoyun; Wang, Jintao; Li, Zhihao; Zhang, Peiman

    2016-01-01

    Glass hydrometers are simple but effective instruments for measuring the density of liquids. Glass hydrometers calibration based on the Archimedes law, using silicon ring as a reference standard solid density, n-tridecane with density stability and low surface tension as the standard working liquid, based on hydrostatic weighing method designs a glass hydrometer calibration system. Glass hydrometer calibration system uses CCD image measurement system to align the scale of hydrometer and liquid surface, with positioning accuracy of 0.01 mm. Surface tension of the working liquid is measured by Whihemy plate. According to twice glass hydrometer weighing in the air and liquid can calculate the correction value of the current scale. In order to verify the validity of the principle of the hydrostatic weighing method of glass hydrometer calibration system, for measuring the density range of (770-790) kg/m3, with a resolution of 0.2 kg/m3 of hydrometer. The results of measurement compare with the Physikalisch-Technische Bundesanstalt(PTB) ,verifying the validity of the calibration system.

  8. Relative efficiency calibration between two silicon drift detectors performed with a monochromatized X-ray generator over the 0.1-1.5 keV range

    Science.gov (United States)

    Hubert, S.; Boubault, F.

    2018-03-01

    In this article, we present the first X-ray calibration performed over the 0.1-1.5 keV spectral range by means of a soft X-ray Manson source and the monochromator SYMPAX. This monochromator, based on a classical Rowland geometry, presents the novelty to be able to board simultaneously two detectors and move them under vacuum in front of the exit slit of the monochromatizing stage. This provides the great advantage to perform radiometric measurements of the monochromatic X-ray photon flux with one reference detector while calibrating another X-ray detector. To achieve this, at least one secondary standard must be operated with SYMPAX. This paper presents thereby an efficiency transfer experiment between a secondary standard silicon drift detector (SDD), previously calibrated on BESSY II synchrotron Facility, and another one ("unknown" SDD), devoted to be used permanently with SYMPAX. The associated calibration process is described as well as corresponding results. Comparison with calibrated measurements performed at the Physikalisch-Technische Bundesanstalt (PTB) Radiometric Laboratory shows a very good agreement between the secondary standard and the unknown SDD.

  9. Experimental storage of high-level radioactive wastes in the Asse salt mine - technical aspects

    International Nuclear Information System (INIS)

    Gies, H.; Rothfuchs, T.; Feddersen, H.; Graefe, V.; Gross, S.; Hente, B.; Jockwer, N.; Kessels, W.; Schwaegermann, H.

    1988-01-01

    The work performed under this project in the Asse salt mine is an important milepost within the framework schedule of the 'Gorleben Poject' of Physikalisch-Technische Bundesanstalt (PTB). The project phase I (1982 - June 30, 1985) is about to be concluded at the time this report is published. The main points of interest of this project phase cover the planning of the experimental work, the design of experiments, and the first activities for developing the systems for handling the high-level radioactive wastes. The engineering development work has been advanced to the point where construction and manufacture of equipment can be started (transport containers Asse, TB1, collective transport containers, borehole gates, transport vehicles, waste positioning equipment, and borehole casing). Testing of the pipes for the last mentioned task with regard to the material's deformation behaviour will be done by the Dutch ECN as a sub-contractor. First laboratory experiments have been carried out on radiolysis gas formation, to complement the engineering work and the in-situ measuring programmes. (orig./RB) [de

  10. Calorimetric determination of kQ factors for NE 2561 and NE 2571 ionization chambers in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV photons.

    Science.gov (United States)

    Krauss, Achim; Kapsch, Ralf-Peter

    2007-10-21

    The relative uncertainty of the ionometric determination of the absorbed dose to water, D(w), in the reference dosimetry of high-energy photon beams is in the order of 1.5% and is dominated by the uncertainty of the calculated chamber- and energy-dependent correction factors k(Q). In the present investigation, k(Q) values were determined experimentally in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV bremsstrahlung by means of a water calorimeter operated at 4 degrees C. Ionization chambers of the types NE 2561 and NE 2571 were calibrated directly in the water phantom of the calorimeter. The measurements were carried out at the linear accelerator of the Physikalisch-Technische Bundesanstalt. It is shown that the k(Q) factor of a single ionization chamber can be measured with a standard uncertainty of less than 0.3%. No significant variations of k(Q) were found for the different lateral sizes of the radiation fields used in this investigation.

  11. Erkundungen im Spannungsfeld von Pädagogik, Spielspass und technischer Machbarkeit. Gedanken zur Konzeption und Entwicklung spielbasierter digitaler Lernumgebung

    Directory of Open Access Journals (Sweden)

    Florian Berger

    2009-02-01

    Full Text Available Computerspiele sind heute aus der digitalen Medienwelt nicht mehr wegzudenken. Ihre rasante technische Entwicklung sowie ihre hohe Akzeptanz in der Jugendkultur werfen Fragen nach pädagogischer Verwertbarkeit dieses Mediums auf. Auf diesem Gebiet besteht Forschungsbedarf: Für den Einsatz aktueller Spielkonzepte als Lehrmittel existieren keine fundierten Theorien oder Konzepte. Der schöpferische Umgang mit Spielen durch Anwender («Emergent Gameplay» bietet hier durch sein hohes Motivationspotential einen vielversprechenden Ansatz. Die oft wenig beachtete Rolle der digitalen Spielen zugrunde liegenden Softwaretechnik sollte stärkere Berücksichtigung finden: Es existiert einerseits ein für die Akzeptanz beim Anwender notwendiges Minimum, andererseits ist der Einsatz des aktuellen technischen «state of the art» für die Umsetzung pädagogischer und didaktischer Ambitionen durch seine enormen Anforderungen wenig zielführend. Im Ergebnis sind Idee und Spielspass das Mass auch für Anwendungen des Game Based Learn­ing.

  12. Aircrew Exposure from Cosmic Radiation on Commercial Airline Routes

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.J.; McCall, M.J.; Green, A.R.; Bennett, L.G.I.; Pierre, M.; Schrewe, U.J.; O' Brien, K.; Felsberger, E

    2001-07-01

    As a result of the recent recommendations of the ICRP 60, and in anticipation of possible regulation on occupational exposure of Canadian-based aircrew, an extensive study was carried out by the Royal Military College of Canada over a one-year period to measure the cosmic radiation at commercial jet altitudes. A tissue-equivalent proportional counter was used to measure the ambient total dose equivalent rate on 62 flight routes, resulting in over 20,000 data points at one-minute intervals at various altitudes and geomagnetic latitudes (i.e. which span the full cut-off rigidity of the Earth's magnetic field). These data were then compared to similar experimental work at the Physikalisch Technische Bundesanstalt, using a different suite of equipment, to measure separately the low and high linear energy transfer components of the mixed radiation field, and to predictions with the LUIN transport code. All experimental and theoretical results were in excellent agreement. From these data, a semi-empirical model was developed to allow for the interpolation of the dose rate for any global position, altitude and date (i.e. heliocentric potential). Through integration of the dose rate function over a great circle flight path, a computer code was developed to provide an estimate of the total dose equivalent on any route worldwide at any period in the solar cycle. (author)

  13. Ultimate disposal of radioactive waste in the FRG - current progress of projects and perspectives

    International Nuclear Information System (INIS)

    Roesel, H.

    1989-01-01

    In the Federal Republic of Germany, the state is responsible for providing for the ultimate disposal of radioactive waste, whereas the cost is borne by the waste producing establishments. The Federal Ministry for the Environment, Nature Conservation and Reactor Safety, (BMU), as the competent state authority has delegated its responsibilities in this matter to the Physikalisch-Technische Bundesanstalt (PTB). The PTB is allowed to have work done by third parties. For this purpose, the Deutsche Gesellschaft zum Bau und Betrieb von Endlagern fuer Abfallstoffe mbH (DBE) has been founded, which since 1979 is investigating the Gorleben salt dome for suitability to serve as a repository for all type of solid, radioactive waste. The final decisions on site approval can be taken after completion of the underground exploration work, which according to current schedules is expected to be achieved at the end of the 1990s. The other candidate site, the Konrad mine, has been investigated by the GSF in the years 1976 to 1982, and on August 31, 1982 the PTB has filed an application to institute the plan approval procedure for the Konrad mine to be prepared to serve as a waste repository. The plan is expected to be laid open in the first half of 1989, and hearings possibly be held in the second half. In case of plan approval, the site preparation will probably take 3 years, so that the Konrad mine will be ready to receive radioactive waste by the year 1993. (orig.) [de

  14. Radioactive waste in Federal Germany

    International Nuclear Information System (INIS)

    Brennecke, P.; Schumacher, J.; Warnecke, E.

    1988-01-01

    The Physikalisch-Technische Bundesanstalt (PTB) is responsible for the long-term storage and disposal of radioactive waste according to the Federal Atomic Energy Act. On behalf of the Federal Minister of the Environment, Nature Conservation and Nuclear Safety, since 1985, the PTB has been carrying out annual inquiries into the amounts of radioactive waste produced in the Federal Republic of Germany. Within the scope of this inquiry performed for the preceding year, the amounts of unconditioned and conditioned waste are compiled on a producer- and plant-specific basis. On the basis of the inquiry for 1986 and of data presented to the PTB by the waste producers, future amounts of radioactive waste have been estimated up to the year 2000. The result of this forecast is presented. In the Federal Republic of Germany two sites are under consideration for disposal of radioactive waste. In the abandoned Konrad iron mine in Salzgitter-Bleckenstedt it is intended to dispose of such radioactive waste which has a negligible thermal influence upon the host rock. The Gorleben salt dome is being investigated for its suitability for the disposal of all kinds of solid and solidified radioactive wastes, especially of heat-generating waste. Comparing the estimated amount of radioactive wastes with the capacity of both repositories it may be concluded that the Konrad and Gorleben repositories will provide sufficient capacity to ensure the disposal of all kinds of radioactive waste on a long-term basis in the Federal Republic of Germany. 1 fig., 2 tabs

  15. Telematics for hazardous goods transportation; Anwendungen fuer den Transport von kritischen Guetern

    Energy Technology Data Exchange (ETDEWEB)

    Stingl, D [Danzas Logistics GmbH, Hamburg (Germany)

    1999-07-01

    In the course of the integration of the customer Langnese Iglo in autumn 1997 and in view of the already existing general conditions for the implementation of the equlations of the directive on food hygiene (HACCP-concept) as well as the permanently in reasing demand for quality of logistics DANZAS Logistics GmbH, cooperating closely with in deep-frozen goods customer Langnese-Iglo decided to develop a new system of quality assurance for the transportation of deep-frozen goods and apply this system to all its activities. First ideas about standard demands, technical solutions and multi-functional design showed that the project had to be handled in such a flexible way that temperature controlling (for the transportation of deep-frozen goods, temperature-controlled DANZAS-warehouses and all future temperature-controlled transportation) and the monitoring of security-relevant transportation can be integrated in one and the same project. (orig.) [German] Im Zuge der Integration des Kunden Langnese Iglo im Herbst 1997 und unter Beruecksichtigung der bereits vorliegenden Rahmenbedingungen zur Umsetzung der Bestimmungen der Lebensmittelhygieneverordnung (HACCP-Konzept) sowie des staendig wachsenden Qualitaetsanspruches an logistische Dienstleistungen, hat sich die DANZAS Logistics GmbH in enger Zusammenarbeit mit dem TK-Kunden Langnese Iglo entschlossen, ein innovatives System zur Qualitaetssicherung im Tiefkuehltransport zu erarbeiten und flaechendeckend einzusetzen. Die ersten Gedanken bezueglich Standardanforderungen, technischer Loesungsansaetze und multifunktionaler Ausrichtung zeigten, dass dieses Projekt so variabel zu gestalten ist, dass sowohl Temperaturcontrolling (fuer TK-Transporte, fuer die temperaturgefuehrten DANZAS-Laeger und zukuenftig alle temperaturgefuehrten Transporte) als auch die Ueberwachung sicherheitsrelevanter Transporte zu integrieren sind. (orig.)

  16. 31. MPA seminar 2005. Proceedings; 31. MPA-Seminar 2005. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    The proceedings volume contains 41 contributions on the following subjects: Safety, availability, life cycle management, damage prevention and quality assurance of power plants. [German] Dieser Tagungsband enthaelt insgesamt 41 Beitraege mit folgenden Themenschwerpunkten: Sicherheit, Verfuegbarkeit, Lebensdauermanagement, Schadensvermeidung sowie Qualitaetssicherung von Kraftwerken.

  17. Numerical and experimental results of the operational neutron dosemeter 'Saphydose-N'

    International Nuclear Information System (INIS)

    Lahaye, T.; Chau, Q.; Menard, S.; Ndontcheung-Moyo, M.; Bolognese-Milsztajn, T.; Rannou, A.

    2004-01-01

    Since 1993, the Inst. for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricite de France (EDF), a R and D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics. (authors)

  18. Monte Carlo evaluation of the neutron detection efficiency of a superheated drop detector

    Energy Technology Data Exchange (ETDEWEB)

    Gualdrini, G F [ENEA, Centro Ricerche ` Ezio Clementel` , Bologna (Italy). Dipt. Ambiente; D` Errico, F; Noccioni, P [Pisa, Univ. (Italy). Dipt. di Costruzioni Meccaniche e Nucleari

    1997-03-01

    Neuron dosimetry has recently gained renewed attention, following concerns on the exposure of crew members on board aircraft, and of workers around the increasing number of high energy accelerators for medical and research purpose. At the same time the new operational qualities for radiation dosimetry introduced by ICRU and the ICRP, aiming at a unified metrological system applicable to all types of radiation exposure, involved the need to update current devices in order to meet new requirements. Superheated Drop (Bubble) Detectors (SDD) offer an alternative approach to neutron radiation protection dosimetry. The SDDs are currently studied within a large collaborative effort involving Yale University. New Haven CT, Pisa (IT) University, the Physikalisch-Technische Bundesanstalt, Braunschweig D, and ENEA (Italian National Agency for new Technologies Energy and the Environment) Centre of Bologna. The detectors were characterised through calibrations with monoenergetic neutron beams and where experimental investigations were inadequate or impossible, such as in the intermediate energy range , parametric Monte Carlo calculations of the response were carried out. This report describes the general characteristic of the SDDs along with the Monte Carlo computations of the energy response and a comparison with the experimental results.

  19. Assessment of Intercomparison of Radionuclide Activity Measurement between P3KRBiN-BATAN and NMIJ/AIST-JAPAN

    International Nuclear Information System (INIS)

    Nazaroh; Pujadi; Hermawan Candra; Ermi Juita; Holnisar

    2003-01-01

    On every radionuclide activity measurements or any measurements always contain uncertainties. The uncertainties come from standard source, equipment to be used, condition of measurements (background) and sample (measurement). Those elements should be taken into account in the measurement result evaluation. To know the result of activity measurement was in a good agreement or not, it can be done by intercomparison. A good result of a measurement if it was nearly with the result of international/primary laboratories measurements such as System Internationale de Reference (SIR)-Franch, National Metrology Institute of Japan- Advanced Industrial Science and Technology (NMIJ/AIST or Physikalisch Technische Bundes-anstalt (PTB) and the absolute value of E n should be less than 1. The result of intercomparison between Center for Research and Development of Radiation Safety and Nuclear Biomedicine (P3KRBiN) -BATAN and NMIJ/AIST were in a good agreement for activity measurement of 125 I (E n =0.193), 58 Co(E n =0.503), 88 Y(E n =0.035) and 59 Fe(E n =0.632), by using gamma spectrometry counting system (HPGe detector) and 166m Ho(E n =0.492), by using Merlin Gerin Ionization chamber. (author)

  20. New x-ray parallel beam facility XPBF 2.0 for the characterization of silicon pore optics

    Science.gov (United States)

    Krumrey, Michael; Müller, Peter; Cibik, Levent; Collon, Max; Barrière, Nicolas; Vacanti, Giuseppe; Bavdaz, Marcos; Wille, Eric

    2016-07-01

    A new X-ray parallel beam facility (XPBF 2.0) has been installed in the laboratory of the Physikalisch-Technische Bundesanstalt at the synchrotron radiation facility BESSY II in Berlin to characterize silicon pore optics (SPOs) for the future X-ray observatory ATHENA. As the existing XPBF which is operated since 2005, the new beamline provides a pencil beam of very low divergence, a vacuum chamber with a hexapod system for accurate positioning of the SPO to be investigated, and a vertically movable CCD-based camera system to register the direct and the reflected beam. In contrast to the existing beamline, a multilayer-coated toroidal mirror is used for beam monochromatization at 1.6 keV and collimation, enabling the use of beam sizes between about 100 μm and at least 5 mm. Thus the quality of individual pores as well as the focusing properties of large groups of pores can be investigated. The new beamline also features increased travel ranges for the hexapod to cope with larger SPOs and a sample to detector distance of 12 m corresponding to the envisaged focal length of ATHENA.

  1. High-accuracy X-ray detector calibration based on cryogenic radiometry

    Science.gov (United States)

    Krumrey, M.; Cibik, L.; Müller, P.

    2010-06-01

    Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

  2. High-accuracy X-ray detector calibration based on cryogenic radiometry

    International Nuclear Information System (INIS)

    Krumrey, M.; Cibik, L.; Mueller, P.

    2010-01-01

    Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

  3. A traceability establishment for the 125I IsoSeed I25.S06 source from Bebig at the hospital level; Propuesta de obtencion de trazabilidad a nivel hospitalario para la fuente de 125I IsoSeed I25.S06 de Bebig

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Calatayud, J.; Bejar, M.J.; Lliso, F.; Colmenares, R.; Fernandez, J.; Andrassy, M.; Carmona, V.; Ferrer, N.; Vivanco, J.

    2010-07-01

    The purpose of this work has been on one side to solve the traceability problem in hospitals for the I25.S06 seed users, already solved for other seeds, and on the other to design a holder in order to allow the measurement of the reference air-kerma rate for the strand by means of a well-type ionization chamber, widely used in brachytherapy in hospitals. At a joint calibration-measurement session of the involved institutions the following steps were performed: calibration of the HDR 1000 and SourceCheck detectors with a standard source from the Physikalisch-Technische Bundesanstalt (PTB); reference air-kerma rate measurements for the 5 seeds strand provided by Bebig with the SourceCheck detector and with the HDR 1000 detector and the new insert holder by SIHO (Spain); separation of the stranded seeds by the specialist from Bebig who dissolved the plastic; reference air-kerma rate measurement of each of the seeds of the strand with one of the of HDR 1000 detectors previously calibrated. We present the calibration factors obtained and the analysis of the uncertainties associated with the process. (Author).

  4. Functional description of PreSRM v1.3. Technical manual for use of PreSRM (Preprocessor Standard Calculation Methods); Functionele omschrijving PreSRM v1.3. Technische handleiding voor gebruik van PreSRM (Preprocessor Standaard RekenMethoden)

    Energy Technology Data Exchange (ETDEWEB)

    Vermeulen, A.T. [ECN Environment and Energy Engineering, Petten (Netherlands)

    2013-07-15

    The PreSRM software library is prescribed in The Netherlands by the government to be used in the dispersion modeling of air pollution when evaluating air quality guidelines in outside air. The code is maintained by ECN and needs to be updated annually. This technical manual describes the use of PreSRM by programmers and documents the update for the current year 2013, including all updated meteorological and air quality background information for the year 2012 [Dutch] PreSRM is een software bibliotheek voor rekenmodellen gebruikt bij de beoordeling van luchtkwaliteit. In Nederland schrijft de Regeling Beoordeling Luchtkwaliteit (RBL) voor onder welke condities welke rekenmethodes gebruikt moeten worden om aan de luchtkwaliteitsnormen te toetsen. In de RBL worden drie Standaard RekenMethodes (SRM's) beschreven. Tevens wordt daarin vastgesteld welke invoergegevens gebruikt moeten worden voor emissies, achtergrondconcentraties, meteorologie en terreinruwheid. Deze gegevens worden jaarlijks geactualiseerd. Dit rapport is een technische handleiding voor de programmeurs en ontwikkelaars van de implementaties van standaard rekenmethoden en systeembeheerders van gebruikers en beschrijft aanpassingen in de huidige versie van de bibliotheek.

  5. Was ein Wort bedeutet, kann ein Satz nicht sagen: Zur Bedeutung der Terminologiearbeit für die Technische Kommunikation und das Fachtextübersetzen

    Directory of Open Access Journals (Sweden)

    Klaus-Dirk Schmitz

    2010-05-01

    Full Text Available Einleitung: Dieser Beitrag geht von einem Zitat des österreichisch-britischen Philosophen Ludwig Wittgenstein aus und bezeiht sich auf seine Aussagen über Wörter und Sätze. Zielsetzung: Analyse und Diskussion der Relevanz von WittgensteinsAussage für die Terminologiearbeit in der Technischen Kommunikation und beim Fachübersetzen. Methode: Kritische Analyse und Betrachtung. Ergebnis: Neben den terminologischen Grundbegriffen Begriff, Benennung und Gegenstand werden vor allem die Definition als Begriffsbeschreibung sowie die Kriterien zur Bildung von Benennungen untersucht. Schlussfolgerung: Das Zitat von Wittgenstein lässt viele Interpretationen zu. Für die Technische Kommunikation und das Fachübersetzen muss aber die Definition (Satz den Begriff hinter der Benennung (Wort erklären. Idealerweise ist aber die Benennung so transparent, dass dadurch schon die Begriffsklärung erfolgt.

  6. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system

    Energy Technology Data Exchange (ETDEWEB)

    Zboray, Robert [Paul Scherrer Institute, PSI Villigen 5232 (Switzerland); Dangendorf, Volker; Bromberger, Benjamin; Tittelmeier, Kai [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig 38116 (Germany); Mor, Ilan [Soreq NRC, Yavne 81800 (Israel)

    2015-07-15

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  8. Radiation measurement of civil air flight

    International Nuclear Information System (INIS)

    Winter, M.

    1999-01-01

    In order to aquire knowledge of the radiation exposure of civil aircrew members in common flight altitudes, it was necessary to develop a practicable measurement system. Radiation exposure was hereby estimated by using the ACREM-System, which is patented by the Austrian Research Centres Seibersdorf (OEFZS). Total Equivalent Dose could be estimated in a simple way by combining a measured component of the radiation field in flight altitudes and the results of simulation with LUIN 94 particle transport code (Keran O'Brian). To verify the results of the measurement system, a tissue equivalent proportional counter (TEPC) was used. Because of the difficult measurement conditions in cargo airplanes, special attention had to be taken to make the measurement equipment easy to use and transport. Special software has been developed to automate the measurement and the evaluation of the large amount of collected data. Measurements in standard calibration photon fields for the characterization of the equipment could be performed at the Primary Dosimetry Laboratory for Austria at the Austrian Research Centre (OEFZS) in Seibersdorf. Additional measurements were performed at Physikalisch Technische Bundesanstalt Braunschweig (PTB, Germany) and Paul Scherer Institute (PSI, Switzerland) to determine the reponse of the instruments to high energy photon and standard neutron fields. (author)

  9. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber; Estabelecimento de um sistema padrao primario para raios-X de energias baixas com uma camara de ionizacao de ar livre

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Natalia Fiorini da

    2016-08-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  10. Fast and high-energy neutron detection with nuclear track detectors: Results of the European joint experiments 1992/93

    Energy Technology Data Exchange (ETDEWEB)

    Schraube, H. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany); Alberts, W.G. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Weeks, A.R. [comps.] [Nuclear Electric plc, Berkeley (United Kingdom). Berkeley Technology Centre

    1997-12-31

    Under the auspices of EURADOS, the European radiation dosimetry group, seventeen recognised laboratories engaged in the field of individual neutron dosimetry with passive track detectors participated in an international comparative experiment. A number of twenty-seven detector systems, predominantly etched track detectors with the material PADC (poly allyl diglycol carbonate), were employed by the participating laboratories. Quasi-monoenergetic neutrons were provided for irradiations free-in-air and on front of a PMMA phantom by the GSF (Forschungszentrum fuer Umwelt und Gesundheit, Neuherberg, Germany) and by the PTB (Physikalisch-Technische Bundesanstalt, Braunschweig, Germany). High energy irradiations were conducted by the PSI (Paul-Scherrer Institut, Villigen, Switzerland). The results of the on-phantom irradiations were used to derive energy and angular responses of the track detectors, those of the free-in-air irradiations to obtain data for the linearity characteristics of the response with dose. The report contains a short description and the original data of the participating laboratories, displays the irradiation and reference conditions, and provides an over-all evaluation. Emphasis is placed on the quantitative evaluation of the background characteristics and of the non-linearity observed with most of the systems employed which limits their useful dose-range of application. (orig.)

  11. Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system.

    Science.gov (United States)

    Zboray, Robert; Dangendorf, Volker; Mor, Ilan; Bromberger, Benjamin; Tittelmeier, Kai

    2015-07-01

    In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.

  12. Establishment of a primary standard system for low energy X-rays using a free air ionization chamber

    International Nuclear Information System (INIS)

    Silva, Natalia Fiorini da

    2016-01-01

    In this work a primary standard system was established for low energy X-rays (10 kV to 50 kV), using a free air ionization chamber with concentric cylinders, Victoreen (Model 481-5), at the Calibration Laboratory of Instruments (LCI) of the Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP). For this, a new ionization chamber alignment protocol was developed for the radiation system and a modification on the micrometer housing used for the movement of the internal cylinders was ma de. The results obtained for the stability and characterization tests showed to be within the limits established by the standards IEC 61674 and IEC 60731. The correction factors for photon attenuation in the air, transmission and scattering in the diaphragm, scattering and fluorescence and ion recombination were also determined. These values were compared with those obtained by the German primary standard laboratory, Physikalisch-Technische Bundesanstalt (PTB), showing good agreement. Finally, the absolute values of the quantity air kerma rate for the standard qualities direct beams MWV28 and WMV35 and the attenuated beams WMH28 and WMH35 were determined; the results are in agreement, with a maximum difference of 3,8% with the values obtained using the secondary standard system of LCI. (author)

  13. Pyrolysis of petroleum residues while making use of the hydrogen potential of polymer waste; Pyrolyse von Erdoelrueckstaenden unter Nutzung des Wasserstoffpotentials von Polymerabfaellen

    Energy Technology Data Exchange (ETDEWEB)

    Klemens, I; Butz, T; Rahimian, I; Linde, A [Institut fuer Erdoel- und Erdgasforschung, Clausthal-Zellerfeld (Germany)

    1998-09-01

    The hydrogen potential contained in waste plastics is to be utilized optimally for cracking of petroleum residues. Homogeneous distribution of the plastic particles in the petroleum residue is to ensure short distances between the hydrogen donor and acceptor, a sufficently large reaction surface, and stable mixing for further processing. Apart from homogeneity, another factor of interest is the influence of mixed-in polymer particles on the colloidal stability of the petroleum residue and the physico-chemical properties of the mixtures. With a view to further processing, the mixtures were analyzed for high-temperature stability, flow characteristics, and reaction behaviour during pyrolysis. (orig.) [Deutsch] Ziel dieses Vorhabens ist es, das in den Kunststoffabfaellen vorhandene Wasserstoffpotential optimal fuer eine tiefergehende Spaltung der Erdoelrueckstaende nutzbar zu machen. Durch eine homogene Verteilung der Kunststoffpartikel im Erdoelrueckstand soll ein moeglichst kurzer Transportweg zwischen Wasserstoff-Donor und -Akkzeptor, eine ausreichend grosse Reaktionsoberflaeche und eine fuer weitere Verarbeitungsschritte notwendige stabile Mischung erreicht werden. Ebenso interessant wie die Homogenitaet solcher Gemische ist auch der Einfluss der eingemengten Polymerteilchen auf die Kolloidstabilitaet des Erdoelrueckstandes und die physikalisch-chemischen Eigenschaften der Mischungen. Im Hinblick auf eine technische Weiterverarbeitung werden die Gemische besonders auf ihre Stabilitaet bei erhoehten Temperaturen (Heisslagerstabilitaet), ihr Fliessverhalten sowie ihr Reaktionsverhalten waehrend der Pyrolyse untersucht. (orig.)

  14. Quality assurance for primary batteries. Qualitaetssicherung fuer Primaerbatterien

    Energy Technology Data Exchange (ETDEWEB)

    Ruedinger, G [Varta AG, Ellwangen (Germany, F.R.)

    1989-11-01

    Apart from a few applications in tube sets, the use of primary batteries was limited until well into the fifties to the current supply of lighting units, predominantly of flashlights. Only with the invention of the transistor and of integrated circuits, the primary battery took an important place among electric components. As a consequence, this component had to meet much different requirements. In order to ensure the quality of an article produced in enormous quantities - several hundred million units per year with a great variety of types, with nine different systems and of approx. 100 different types - it became indispensable to set up a well equipped quality assurance system. (orig.).

  15. Integration of a silicon-based microprobe into a gear measuring instrument for accurate measurement of micro gears

    International Nuclear Information System (INIS)

    Ferreira, N; Krah, T; Jeong, D C; Kniel, K; Härtig, F; Metz, D; Dietzel, A; Büttgenbach, S

    2014-01-01

    The integration of silicon micro probing systems into conventional gear measuring instruments (GMIs) allows fully automated measurements of external involute micro spur gears of normal modules smaller than 1 mm. This system, based on a silicon microprobe, has been developed and manufactured at the Institute for Microtechnology of the Technische Universität Braunschweig. The microprobe consists of a silicon sensor element and a stylus which is oriented perpendicularly to the sensor. The sensor is fabricated by means of silicon bulk micromachining. Its small dimensions of 6.5 mm × 6.5 mm allow compact mounting in a cartridge to facilitate the integration into a GMI. In this way, tactile measurements of 3D microstructures can be realized. To enable three-dimensional measurements with marginal forces, four Wheatstone bridges are built with diffused piezoresistors on the membrane of the sensor. On the reverse of the membrane, the stylus is glued perpendicularly to the sensor on a boss to transmit the probing forces to the sensor element during measurements. Sphere diameters smaller than 300 µm and shaft lengths of 5 mm as well as measurement forces from 10 µN enable the measurements of 3D microstructures. Such micro probing systems can be integrated into universal coordinate measuring machines and also into GMIs to extend their field of application. Practical measurements were carried out at the Physikalisch-Technische Bundesanstalt by qualifying the microprobes on a calibrated reference sphere to determine their sensitivity and their physical dimensions in volume. Following that, profile and helix measurements were carried out on a gear measurement standard with a module of 1 mm. The comparison of the measurements shows good agreement between the measurement values and the calibrated values. This result is a promising basis for the realization of smaller probe diameters for the tactile measurement of micro gears with smaller modules. (paper)

  16. List of Participants

    Science.gov (United States)

    2008-11-01

    MoralIstituto Nazionale di Fisica Nucleare, Università di Torino Valentina Giangreco Marotta PulettiUppsala University Valeria L GiliQueen Mary, University of London Luciano GirardelloUniversità di Milano-Bicocca Gian GiudiceCERN, Geneva Kevin Goldstein Institute for Theoretical Physics, Utrecht University Joaquim Gomis Universitat de Barcelona Pietro Antonio GrassiUniversità del Piemonte Orientale, Alessandria Viviane GraßLudwig-Maximilians-Universität, München Gianluca Grignani Università di Perugia Luca Griguolo Università di Parma Johannes GrosseJagiellonian University, Krakow Umut Gursoy École Polytechnique, Palaiseau Norberto Gutierrez RodriguezUniversity of Oviedo Babak HaghighatPhysikalisches Institut, Universität Bonn Troels Harmark Niels Bohr Institute, København Robert HaslhoferEidgenössische Technische Hochschule (ETH), Zürich Tae-Won HaPhysikalisches Institut, Universität Bonn Alexander HauptImperial College London and Max-Planck-Institut für Gravitationsphysik (AEI), Potsdam Marc HenneauxUniversité Libre de Bruxelles Johannes HennLAPTH, Annecy-le-Vieux Shinji HiranoNiels Bohr Institute, København Stefan HoheneggerEidgenössische Technische Hochschule (ETH), Zürich Jan HomannLudwig-Maximilians-Universität, München Gabriele Honecker CERN, Geneva Joost HoogeveenInstituut voor Theoretische Fysica, Universiteit van Amsterdam Mechthild HuebscherUniversidad Autónoma de Madrid Chris HullImperial College London Carmen-Liliana IonescuUniversity of Craiova Ella JasminUniversité Libre de Bruxelles Konstantin KanishchevInstitute of Theoretical Physics, University of Warsaw Stefanos Katmadas Utrecht University Alexandros KehagiasNational Technical University of Athens Christoph Keller Eidgenössische Technische Hochschule (ETH), Zürich Patrick Kerner Max-Planck-Institut für Physik, München Rebiai KhaledLaboratoire de Physique Mathématique et Physique Subatomique, Université Mentouri, Constantine Elias Kiritsis Centre de Physique Théorique,

  17. John Adams Lecture | 120 Years of Accelerators that Heal | 3 December

    CERN Multimedia

    2013-01-01

    120 Years of Accelerators that Heal, Dr Ugo Amaldi, Technische Universität München and TERA Foundation.     Tuesday 3 December 2013 at 2 p.m. Kjell Johnsen Auditorium, Building 30 Abstract: The discovery of X-rays was made possible by the intelligent use of the best accelerator of the time. Since then, the development of particle accelerators has been at the root of both fundamental discoveries in physics and unforeseeable medical applications. The lecture will describe the major steps in this 120-year history of diagnostics and tumour therapy. The first attempts to heal tumours with X-rays were made only one month after Röntgen’s discovery, but the understanding of the mechanisms by which the radiation kills the cells and the introduction of dose fractionation took much longer. The use of X-rays in diagnostics developed much faster and its benefits were very visible during the First World War. Today no tumour could be treated and no patient could be oper...

  18. Shortcomings of the industrial quality assurance of {sup 106}Ru ophthalmic plaques; Therapierelevante Schwachstellen bei der industriellen Qualitaetssicherung von {sup 106}Ru-Augenapplikatoren

    Energy Technology Data Exchange (ETDEWEB)

    Kaulich, T.W.; Nuesslin, F. [Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany). Abt. Medizinische Physik; Zurheide, J. [BrainLAB AG, Heimstetten (Germany); Fluehs, D. [Abt. Strahlentherapie, Bereich klinische Strahlenphysik, Universitaetsklinikum Essen (Germany); Haug, T. [Isotopenlabor der Univ. Tuebingen (Germany); Bamberg, M. [Abt. Radioonkologie, Universitaetsklinik fuer Radioonkologie, Tuebingen (Germany)

    2001-11-01

    , Oberflaechenkontaminationspruefung, Dichtheitspruefung, Dosisleistungsueberpruefung. Die Oberflaechenkontaminationspruefung besteht aus einer feuchten Wischprobe unter leichtem Druck. Zur Ueberpruefung der Dichtheit der {sup 106}Ru-Augenapplikatoren wurde ein klinisch relevantes Szenario entwickelt, bei dem der Kontakt der Augenapplikatoren mit Humangewebe simuliert wird. Dabei wird der Applikator mehrere Tage in Ringer-Loesung eingelegt. Die zertifizierten Energiedosisleistungsangaben des Herstellers werden mit einem 1 mm{sup 3} grossen Plastikszintillator auf Konsistenz geprueft. Ergebnisse: Bei den klinikinternen Eingangspruefungen von {sup 106}Ru-Augenapplikatoren unterschiedlicher Groesse ergaben sich folgende Resultate: Die Dichtheitspruefung wurde an sieben Applikatoren durchgefuehrt. Dabei wurden Kontaminationen bei den Wischproben bis 57 Bq und in der Ringer-Loesung bis 520 Bq gemessen. Bei der dosimetrischen Konsistenzpruefung der zertifizierten Dosisleistungsangabe von 14 Applikatoren zeigte sich bei sechs Applikatoren gute Uebereinstimmung mit einem Variationskoeffizienten von 2,6%. Bei acht Applikatoren lagen die Abweichungen zwischen -37% und +74%, d.h., die Spannweite dieser nicht akzeptablen Applikatoren betrug 111%. Die Ergebnisse wurden exemplarisch durch externe Begutachtung bestaetigt. Schlussfolgerung: Bei der klinikinternen Eingangspruefung von {sup 106}Ru-Augenapplikatoren wurden schwerwiegende therapierelevante Schwachstellen der industriellen Qualitaetssicherung festgestellt. Es ist deshalb notwendig, dass {sup 106}Ru-Augenapplikatoren vor klinischem Einsatz intern ueberprueft werden. Die hierzu entwickelte Eingangspruefung kann von anderen Kliniken direkt uebernommen werden. (orig.)

  19. Selection of compressors and drives for natural gas storage and transport - technical and economic aspects; Auswahl von Verdichtern und Antriebsmaschinen fuer die Erdgasspeicherung und den Erdgastransport - technische und wirtschaftliche Aspekte

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, F.; Wieke, S. [Heyer und Wieke Engineering, Muenchen (Germany)

    1998-12-31

    Selection of the proper compressor/drive combination is indispensable for optimizing natural gas storage. The contribution presents a comparison of the available systems. (orig.) [Deutsch] Fuer die Verdichtung von Erdgas fuer die Erdgasspeicherung und den Erdgastransport ist die Auswahl der fuer den jeweiligen Anwendungsfall geeigneten Verdichter-Antriebskombination eine wesentliche Voraussetzung fuer einen technisch und wirtschaftlich optimalen Betrieb. Unter Beruecksichtigung des Marktes werden die Varianten (Verdichter-Antriebskombinationen) definiert und in einem technischen Vergleich Vor- und Nachteile der einzelnen Alternativen gegenuebergestellt und bewertet. Die Einhaltung der Betriebsanforderungen und der Anforderungen der TA-Luft und TA-Laerm, der Wirkungsgrad, die Zuverlaessigkeit und Verfuegbarkeit muessen einer besonders intensiven Pruefung und Beurteilung unterzogen werden. Das Ergebnis der vergleichenden Bewertung der Varianten kann eine neue Definition der Varianten oder der Anforderungen notwendig machen. (orig.)

  20. X-ray pencil beam facility for optics characterization

    Science.gov (United States)

    Krumrey, Michael; Cibik, Levent; Müller, Peter; Bavdaz, Marcos; Wille, Eric; Ackermann, Marcelo; Collon, Maximilien J.

    2010-07-01

    The Physikalisch-Technische Bundesanstalt (PTB) has used synchrotron radiation for the characterization of optics and detectors for astrophysical X-ray telescopes for more than 20 years. At a dedicated beamline at BESSY II, a monochromatic pencil beam is used by ESA and cosine Research since the end of 2005 for the characterization of novel silicon pore optics, currently under development for the International X-ray Observatory (IXO). At this beamline, a photon energy of 2.8 keV is selected by a Si channel-cut monochromator. Two apertures at distances of 12.2 m and 30.5 m from the dipole source form a pencil beam with a typical diameter of 100 μm and a divergence below 1". The optics to be investigated is placed in a vacuum chamber on a hexapod, the angular positioning is controlled by means of autocollimators to below 1". The reflected beam is registered at 5 m distance from the optics with a CCD-based camera system. This contribution presents design and performance of the upgrade of this beamline to cope with the updated design for IXO. The distance between optics and detector can now be 20 m. For double reflection from an X-ray Optical Unit (XOU) and incidence angles up to 1.4°, this corresponds to a vertical translation of the camera by 2 m. To achieve high reflectance at this angle even with uncoated silicon, a lower photon energy of 1 keV is available from a pair of W/B4C multilayers. For coated optics, a high energy option can provide a pencil beam of 7.6 keV radiation.

  1. Modelation and simulation of technical systems. An introduction close to practice; Modellierung und Simulation technischer Systeme. Eine praxisnahe Einfuehrung

    Energy Technology Data Exchange (ETDEWEB)

    Nollau, Reiner [HAWK Hochschule fuer Angewandte Wissenschaft und Kunst - FH Hildesheim/Holzminden/Goettingen, Goettingen (Germany). Fakultaet Naturwissenschaften und Technik

    2009-07-01

    There is a growing trend towards using calculation programmes to design and optimise technical systems. Such programmes simulate the systems' dynamic behaviour on the basis of mathematical models. This book first presents the methods used for model identification and model description. A widely applicable basic algorithm has been derived by means of these methods. Creating an overview block diagram of the system under study constitutes an important step of model development. The methods elaborated by the author are applied to numerous examples ordered in a sequence of growing complexity and hence difficulty. The examples each end with calculations on the model's behaviour, the results of which the reader can verify. Using the applied basic algorithm as a basis the reader can efficiently examine other systems not addressed in the book. [German] Technische Systeme werden immer staerker mit Hilfe von Rechnerprogrammen entworfen und optimiert. Die Programme simulieren das dynamische Verhalten der Systeme auf der Basis von mathematischen Modellen. In diesem Buch wird zunaechst die Methodik der Modellermittlung und -beschreibung dargelegt, aus welcher ein breit anwendbarer Grundalgorithmus abgeleitet worden ist. Eine wichtige Stufe der Modellentwicklung ist das Gesamt-Blockschaltbild des untersuchten Systems. Die vom Autor erarbeitete Methodik wird auf zahlreiche Beispiele wachsender Komplexitaet und damit wachsenden Schwierigkeitsgrades angewendet. Diese Beispiele enden mit Berechnungen des Verhaltens dieser Modelle, deren Ergebnisse der Leser nachpruefen kann. Der Leser kann auf der Grundlage des angewendeten Grundalgorithmus zielstrebig andere, im Buch nicht behandelte, Systeme untersuchen. (orig.)

  2. Magnetic resonance imaging of pulmonary perfusion. Technical requirements and diagnostic impact; MRT der Lungenperfusion. Technische Voraussetzungen und diagnostischer Stellenwert

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Buesing, K.; Schoenberg, S.O.; Fink, C. [Klinikum Mannheim der Universitaet Heidelberg, Institut fuer Klinische Radiologie und Nuklearmedizin, Universitaetsmedizin Mannheim, Mannheim (Germany); Ingrisch, M.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Campus Grosshadern, Muenchen (Germany)

    2009-08-15

    With technical improvements in gradient hardware and the implementation of innovative k-space sampling techniques, such as parallel imaging, the feasibility of pulmonary perfusion MRI could be demonstrated in several studies. Dynamic contrast-enhanced 3D gradient echo sequences as used for time-resolved MR angiography have been established as the preferred pulse sequences for lung perfusion MRI. With these techniques perfusion of the entire lung can be visualized with a sufficiently high temporal and spatial resolution. In several trials in patients with acute pulmonary embolism, pulmonary hypertension and airway diseases, the clinical benefit and good correlation with perfusion scintigraphy have been demonstrated. The following review article describes the technical prerequisites, current post-processing techniques and the clinical indications for MR pulmonary perfusion imaging using MRI. (orig.) [German] Mit der Verfuegbarkeit leistungsfaehiger Gradientensysteme und schneller k-Raum-Akquisitionstechniken wie der parallelen Bildgebung konnten verschiedene Studien die Machbarkeit der Lungenperfusionsbildgebung in der MRT zeigen. In der Praxis haben sich dynamische kontrastverstaerkte 3D-Gradientenechosequenzen, wie sie fuer zeitaufgeloeste MR-Angiographien verwendet werden, fuer die Bildgebung der Lungenperfusion etabliert. Hiermit ist es moeglich, die Perfusion der gesamten Lunge mit ausreichend hoher zeitlicher und raeumlicher Aufloesung zu visualisieren. In mehren klinischen Studien konnte bei Patienten mit Lungenembolie, pulmonaler Hypertonie sowie Erkrankungen der Atemwege und des Lungenparenchyms der klinische Nutzen der Lungenperfusions-MRT und die gute Uebereinstimmung mit der Lungenperfusionsszintigraphie nachgewiesen werden. Der folgende Uebersichtsartikel beschreibt die technische Durchfuehrung, Bildnachverarbeitung und die klinischen Anwendungsgebiete der MRT zur Untersuchung der Lungenperfusion. (orig.)

  3. Primary standardization of cesium-137 for international intercomparison

    International Nuclear Information System (INIS)

    Srivastava, P.K.

    1977-01-01

    Primary standards of cesium-137 are of great importance for precise radiation measurements because, due to its simple decay-scheme and long half-life, it is widely used for the calibration of radiation detectors. Also 137 Cs is used for the measurement of fission-yield and uranium burn-up in reactor engineering studies. In view of these, an international intercomparison was organised on a limited scale to correlate the standards established at the Bhabha Atomic Research Centre (BARC), Bombay(India) and Physikalisch-Technische Bundesanstalt (PTB), West Germany. The ''efficiency tracing technique'' was developed at BARC for the primary standardization of 137 Cs for this intercomparison. Two tracers, namely 82 Br and 60 Co, were employed to trace the beta efficiency of the 4 πβ-γ coincidence counting system. It is shown that this technique offers high accuracy and inherent reliability. The ''tracing-technique'' for 137 Cs standardization is briefly described. The gravimetric method of dilution and preparation of mixed sources of 137 Cs - 82 Br and 137 Cs - 60 Co are given. The various counting parameters and settings are included. Data reduction and the estimation of systematic and statistical errors are discussed. The results of the intercomparison, which are also included, show that the agreement between the measurments of BARC and PTB is within 0.5%. (author)

  4. Development of a standard operating procedure for mammography equipment used in calibration of ionized chambers

    International Nuclear Information System (INIS)

    Rodrigues, Yklys Santos; Potiens, Maria da Penha Albuquerque

    2011-01-01

    Mammography is one widely used technique in the detection of breast cancer. In order to optimize the results achieving better images with lower dose rates, a quality assurance programme must be applied to the equipment. Some control tests use ionization chambers to measure air kerma and other quantities. These tests can only be reliable if the ionization chambers used on them are correctly calibrated. In the present work, it was developed a standard operating procedure (SOP) for quality control tests in a commercial mammography equipment installed in the Calibration Laboratory (LCI) at IPEN - Brazilian Institute for energy and nuclear research). Seven tests were performed in the equipment: Tube voltage and exposition time accuracy and reproducibility, linearity and reproducibility of Air kerma and Half Value Layer (HVL). Then, it was made a measurement of the air kerma in the mammography equipment, using a reference ionization chamber with traceability to a primary laboratory in Germany (Physikalisch-Technische Bundesanstalt - PTB), that was later compared with the air kerma measured in an industrial irradiator. This industrial X-ray generator was recently used in the implementation of X-radiation Standards beams, mammography level, following the Standard IEC 61267. The HVL values varied from 0.36 (25kV) to 0.41 mmA1 (35kV), and the measured air kerma rates were between 9.78 and 17.97 mGy/min. (author)

  5. Diffraction efficiency of radially-profiled off-plane reflection gratings

    Science.gov (United States)

    Miles, Drew M.; Tutt, James H.; DeRoo, Casey T.; Marlowe, Hannah; Peterson, Thomas J.; McEntaffer, Randall L.; Menz, Benedikt; Burwitz, Vadim; Hartner, Gisela; Laubis, Christian; Scholze, Frank

    2015-09-01

    Future X-ray missions will require gratings with high throughput and high spectral resolution. Blazed off-plane reflection gratings are capable of meeting these demands. A blazed grating profile optimizes grating efficiency, providing higher throughput to one side of zero-order on the arc of diffraction. This paper presents efficiency measurements made in the 0.3 - 1.5 keV energy band at the Physikalisch-Technische Bundesanstalt (PTB) BESSY II facility for three holographically-ruled gratings, two of which are blazed. Each blazed grating was tested in both the Littrow configuration and anti-Littrow configuration in order to test the alignment sensitivity of these gratings with regard to throughput. This paper outlines the procedure of the grating experiment performed at BESSY II and discuss the resulting efficiency measurements across various energies. Experimental results are generally consistent with theory and demonstrate that the blaze does increase throughput to one side of zero-order. However, the total efficiency of the non-blazed, sinusoidal grating is greater than that of the blazed gratings, which suggests that the method of manufacturing these blazed profiles fails to produce facets with the desired level of precision. Finally, evidence of a successful blaze implementation from first diffraction results of prototype blazed gratings produce via a new fabrication technique at the University of Iowa are presented.

  6. Stereotactic body radiotherapy for liver tumors. Principles and practical guidelines of the DEGRO Working Group on Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sterzing, Florian [Deutsches Krebsforschungszentrum (DKFZ), Klinische Kooperationseinheit Strahlentherapie, Heidelberg (Germany); Radiologische Universitaetsklinik, Abteilung fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany); Brunner, Thomas B. [Universitaetsklinikum Freiburg, Klinik fuer Strahlenheilkunde, Radiologische Klinik, Freiburg (Germany); Ernst, Iris; Greve, Burkhard [Universitaetsklinikum Muenster, Klinik fuer Strahlentherapie - Radioonkologie, Muenster (Germany); Baus, Wolfgang W. [Universitaetsklinikum Koeln, Klinik und Poliklinik fuer Strahlentherapie, Koeln (Germany); Herfarth, Klaus [Radiologische Universitaetsklinik, Abteilung fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany); Guckenberger, Matthias [UniversitaetsSpital Zuerich, Klinik fuer Radio-Onkologie, Zuerich (Switzerland)

    2014-10-15

    This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a practical guideline for safe and effective stereotactic body radiotherapy (SBRT) of liver tumors. The literature on the clinical evidence of SBRT for both primary liver tumors and liver metastases was reviewed and analyzed focusing on both physical requirements and special biological characteristics. Recommendations were developed for patient selection, imaging, planning, treatment delivery, motion management, dose reporting, and follow-up. Radiation dose constraints to critical organs at risk are provided. SBRT is a well-established treatment option for primary and secondary liver tumors associated with low morbidity. (orig.) [German] Die Arbeitsgruppe Stereotaxie der Deutschen Gesellschaft fuer Radioonkologie (DEGRO) legt hier eine Empfehlung zur sicheren und effektiven Durchfuehrung der SBRT von Lebertumoren vor. Eine Literaturrecherche zur Untersuchung der Evidenz der SBRT sowohl fuer primaere Lebertumore als auch fuer Lebermetastasen wurde durchgefuehrt. Auf dieser Basis werden Empfehlungen fuer technisch-physikalische Voraussetzungen wie auch fuer die taegliche Praxis der Leber-SBRT gegeben. Weiterhin werden radiobiologische Besonderheiten dieses Verfahrens dargestellt. Praktische Vorgaben werden fuer Patientenselektion, Bildgebung, Planung, Applikation, Bewegungsmanagement, Dosisdokumentation und Follow-up gegeben. Dosisempfehlungen fuer die kritischen Risikoorgane werden dargestellt. Die SBRT stellt eine etablierte Behandlungsmethode fuer primaere und sekundaere Lebertumore dar und ist mit niedriger Morbiditaet assoziiert. (orig.)

  7. Calculation of coupled bunch effects in the synchrotron light source BESSY VSR

    Energy Technology Data Exchange (ETDEWEB)

    Ruprecht, Martin

    2016-02-22

    In the scope of this thesis, the strength of coupled bunch instabilities (CBIs) driven by longitudinal monopole higher order modes (HOMs) and transverse dipole and quadrupole HOMs is evaluated for the upgrade project BESSY Variable Pulse Length Storage Ring (BESSY VSR) at Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH (HZB), based on analytic calculations and tracking simulations, and compared to the performance of an active bunch-by-bunch feedback (BBFB). Algorithms for tracking codes are derived, and a semi-empirical formula for the estimation of transverse quadrupole CBIs is presented. CBI studies are an integral part of the benchmarking of the cavity models for BESSY VSR and have been accompanying and influencing their entire design process. Based on the BESSY VSR cavity model with highly advanced HOM damping, beam stability is likely to be reached with a BBFB system, independent of the bunch fill pattern. Additionally, measurements of CBIs have been performed at BESSY II and the Metrology Light Source of the Physikalisch-Technische Bundesanstalt (MLS), where the longitudinal long range impedance was characterized. Transient beam loading is evaluated by means of analytic formulas and new experimentally verified tracking codes. For the baseline bunch fill pattern of BESSY VSR, it is shown that the particular setup of cavity frequencies amplifies the transient effect on the long bunch, limiting its elongation and potentially resulting in increased Touschek losses.

  8. Determination of the characteristic limits and responses of nuclear track detectors in mixed radon and thoron atmospheres

    International Nuclear Information System (INIS)

    Röttger, Annette; Honig, Anja; Schrammel, Dieter; Strauss, Heinrich F.

    2016-01-01

    Closed nuclear track detectors are widely used for the determination of Rn-222 exposures. There are also partial open systems available, which are specially designed for the determination of the exposure to Rn-220, which is a relevant exposure in special workplaces or in specific regions of the world. This paper presents data and a detail analysis of how to determine the cross-correlation by calibration in pure Rn-222 and pure Rn-220 atm. By these means calibration coefficients for the analysis of real mixed atmospheres can be obtained. The respective decision threshold, detection limit and limits of the confidence interval were determined according to ISO 11929 (ISO 11929:2010, 2010). The exposure of detectors was performed at the radon reference chamber and the thoron progeny chamber of the Physikalisch-Technische Bundesanstalt (PTB). The analysis of track response was done at Parc RGM, while the analytical routines were developed in the Leibniz University Hanover, Institute Radioökologie und Strahlenschutz IRS at the working Group AK SIGMA (Arbeitskreis Nachweisgrenzen). - Highlights: • Analysis of exposure in reference atmospheres according ISO 11929. • Calibration of nuclear track detectors for 222 Rn and 220 Rn. • Calculation of cross-correlation by calibration in pure 222 Rn and 220 Rn atmospheres. • Thoron activity concentration should not be omitted in radon exposure determinations.

  9. Computer algebra simulation - what can it do?; Was leistet Computer-Algebra-Simulation?

    Energy Technology Data Exchange (ETDEWEB)

    Braun, S. [Visual Analysis AG, Muenchen (Germany)

    2001-07-01

    Shortened development times require new and improved calculation methods. Numeric methods have long become state of the art. However, although numeric simulations provide a better understanding of process parameters, they do not give a feast overview of the interdependences between parameters. Numeric simulations are effective only if all physical parameters are sufficiently known; otherwise, the efficiency will decrease due to the large number of variant calculations required. Computer algebra simulation closes this gap and provides a deeper understanding of the physical fundamentals of technical processes. [German] Neue und verbesserte Berechnungsmethoden sind notwendig, um die staendige Verkuerzung der Entwicklungszyklen zu ermoeglichen. Herkoemmliche Methoden, die auf einem rein numerischen Ansatz basieren, haben sich in vielen Anwendungsbereichen laengst zum Standard entwickelt. Aber nicht nur die staendig kuerzer werdenden Entwicklungszyklen, sondern auch die weiterwachsende Komplexitaet machen es notwendig, ein besseres Verstaendnis der beteiligten Prozessparameter zu gewinnen. Die numerische Simulation besticht zwar durch Detailloesungen, selbst bei komplexen Strukturen und Prozessen, allerdings liefert sie keine schnelle Abschaetzung ueber die Zusammenhaenge zwischen den einzelnen Parametern. Die numerische Simulation ist nur dann effektiv, wenn alle physikalischen Parameter hinreichend bekannt sind; andernfalls sinkt die Effizienz durch die notwendige Anzahl von notwendigen Variantenrechnungen sehr stark. Die Computer-Algebra-Simulation schliesst diese Luecke in dem sie es erlaubt, sich einen tieferen Einblick in die physikalische Funktionsweise technischer Prozesse zu verschaffen. (orig.)

  10. Activity standardisation of 18F and ionisation chamber calibration for nuclear medicine

    International Nuclear Information System (INIS)

    Schrader, H.; Klein, R.; Kossert, K.

    2007-01-01

    Primary activity standardisations were performed on solutions of 18 F using 4πβ-γ coincidence counting and liquid scintillation counting (LSC) according to the CIEMAT/NIST method. A β + -emission probability of 96.86% was used for both methods. The various standardised 18 F solutions were measured in ionisation chambers of the Physikalisch-Technische Bundesanstalt (PTB) and compared by determining radionuclide calibration factors. Already in 2001 an 18 F solution had been standardised at the PTB and compared with the results of nine national metrology institutes (NMIs), using the ISOCAL IV secondary radionuclide calibrators of the National Physical Laboratory (NPL) as transfer instruments and a 68 Ge check source solution. These results were linked to the International Reference System (SIR) at the Bureau International des Poids et Mesures (BIPM) by aliquots of solutions sent by the Laboratoire National Henri Becquerel (BNM-LNHB) and the NPL. Further on, in 2005, PTB sent an aliquot of an 18 F solution to the SIR for ionisation chamber measurements. A value of the equivalent activity was determined and included in the key comparison database (KCDB). The recent PTB value of the equivalent activity of the SIR is in good agreement with the key comparison reference value determined from five NMIs. These results confirm that the standardisation of 18 F solutions can be achieved with the accuracy required for use in nuclear medicine and, in particular, for applications in positron emission tomography (PET)

  11. Metrology of the Solar Spectral Irradiance at the Top Of Atmosphere in the Near Infrared using Ground Based Instruments. Final results of the PYR-ILIOS campaign (Mauna Loa Observatory, June-July 2016).

    Science.gov (United States)

    Cessateur, G.; Bolsée, D.; Pereira, N.; Sperfeld, P.; Pape, S.

    2017-12-01

    The availability of reference spectra for the Solar Spectral Irradiance (SSI) is important for the solar physics, the studies of planetary atmospheres and climatology. The near infrared (NIR) part of these spectra is of great interest for its main role for example, in the Earth's radiative budget. Until recently, some large and unsolved discrepancies (up to 10 %) were observed in the 1.6 μm region between space instruments, models and ground-based measurements. We designed a ground-based instrumentation for SSI measurements at the Top Of Atmosphere (TOA) through atmospheric NIR windows using the Bouguer-Langley technique. The main instrument is a double NIR spectroradiometer designed by Bentham (UK), radiometrically characterized at the Royal Belgian Institute for Space Aeronomy. It was absolute calibrated against a high-temperature blackbody as primary standard for spectral irradiance at the Physikalisch-Technische Bundesanstalt (Germany). The PYR-ILIOS campaign was carried out in June to July 2016 at the Mauna Loa Observatory (Hawaii, USA, 3396 m a.s.l.) follows the four-month IRESPERAD campaign which was carried out in the summer 2011 at the Izaña Atmospheric Observatory (Canary Islands, 2367 m a.s.l.). We present here the results of the 3'week PYR-ILIOS campaign and compare them with the ATLAS 3 spectrum as well as from recently reprocessed NIR solar spectra obtained with SOLAR/SOLSPEC on ISS and SCIAMACHY on ENVISAT. The uncertainty budget of the PYR-ILIOS results will be discussed.

  12. Limitations of Dower's inverse transform for the study of atrial loops during atrial fibrillation.

    Science.gov (United States)

    Guillem, María S; Climent, Andreu M; Bollmann, Andreas; Husser, Daniela; Millet, José; Castells, Francisco

    2009-08-01

    Spatial characteristics of atrial fibrillatory waves have been extracted by using a vectorcardiogram (VCG) during atrial fibrillation (AF). However, the VCG is usually not recorded in clinical practice and atrial loops are derived from the 12-lead electrocardiogram (ECG). We evaluated the suitability of the reconstruction of orthogonal leads from the 12-lead ECG for fibrillatory waves in AF. We used the Physikalisch-Technische Bundesanstalt diagnostic ECG database, which contains 15 simultaneously recorded signals (12-lead ECG and three Frank orthogonal leads) of 13 patients during AF. Frank leads were derived from the 12-lead ECG by using Dower's inverse transform. Derived leads were then compared to true Frank leads in terms of the relative error achieved. We calculated the orientation of AF loops of both recorded orthogonal leads and derived leads and measured the difference in estimated orientation. Also, we investigated the relationship of errors in derivation with fibrillatory wave amplitude, frequency, wave residuum, and fit to a plane of the AF loops. Errors in derivation of AF loops were 68 +/- 31% and errors in the estimation of orientation were 35.85 +/- 20.43 degrees . We did not find any correlation among these errors and amplitude, frequency, or other parameters. In conclusion, Dower's inverse transform should not be used for the derivation of orthogonal leads from the 12-lead ECG for the analysis of fibrillatory wave loops in AF. Spatial parameters obtained after this derivation may differ from those obtained from recorded orthogonal leads.

  13. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    International Nuclear Information System (INIS)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-01-01

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin

  14. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  15. A cryogenic electrical substitution radiometer for hard X-rays

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G.

    2007-01-01

    Cryogenic electrical substitution radiometers (ESR) are well established in radiometry to determine radiant power with low uncertainties from the infrared to the soft X-ray region. The absorbers are made of copper to achieve a small time constant. At higher photon energies, the use of copper prevents the operation of ESR due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at BESSY II. In the first place, extensive simulations were performed for a variety of materials and absorber geometries using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a 7 T wavelength shifter beamline at BESSY II. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in an absorber with a gold base 500 μm in thickness, inclined by 30 deg., and a cylindrical shell made of copper 80 μm in thickness to reduce losses caused mainly by fluorescence. The absorber was manufactured at PTB by means of electroforming and was implemented into an existing ESR. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative uncertainties below 1%

  16. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Science.gov (United States)

    Troussel, Ph.; Dennetiere, D.; Maroni, R.; Høghøj, P.; Hedacq, S.; Cibik, L.; Krumrey, M.

    2014-12-01

    The "Commissariat à l'énergie atomique et aux énergies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  17. A cryogenic electrical substitution radiometer for hard X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)], E-mail: Martin.Gerlach@ptb.de; Krumrey, M.; Cibik, L.; Mueller, P.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2007-09-21

    Cryogenic electrical substitution radiometers (ESR) are well established in radiometry to determine radiant power with low uncertainties from the infrared to the soft X-ray region. The absorbers are made of copper to achieve a small time constant. At higher photon energies, the use of copper prevents the operation of ESR due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at BESSY II. In the first place, extensive simulations were performed for a variety of materials and absorber geometries using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a 7 T wavelength shifter beamline at BESSY II. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in an absorber with a gold base 500 {mu}m in thickness, inclined by 30 deg., and a cylindrical shell made of copper 80 {mu}m in thickness to reduce losses caused mainly by fluorescence. The absorber was manufactured at PTB by means of electroforming and was implemented into an existing ESR. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative uncertainties below 1%.

  18. A cryogenic electrical substitution radiometer for hard X-rays

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Ulm, G.

    2007-09-01

    Cryogenic electrical substitution radiometers (ESR) are well established in radiometry to determine radiant power with low uncertainties from the infrared to the soft X-ray region. The absorbers are made of copper to achieve a small time constant. At higher photon energies, the use of copper prevents the operation of ESR due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at BESSY II. In the first place, extensive simulations were performed for a variety of materials and absorber geometries using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a 7 T wavelength shifter beamline at BESSY II. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in an absorber with a gold base 500 μm in thickness, inclined by 30°, and a cylindrical shell made of copper 80 μm in thickness to reduce losses caused mainly by fluorescence. The absorber was manufactured at PTB by means of electroforming and was implemented into an existing ESR. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative uncertainties below 1%.

  19. First set of gated x-ray imaging diagnostics for the Laser Megajoule facility

    Energy Technology Data Exchange (ETDEWEB)

    Rosch, R.; Trosseille, C.; Caillaud, T.; Allouche, V.; Bourgade, J. L.; Briat, M.; Brunel, P.; Burillo, M.; Casner, A.; Depierreux, S.; Gontier, D.; Jadaud, J. P.; Le Breton, J. P.; Llavador, P.; Loupias, B.; Miquel, J. L.; Oudot, G.; Perez, S.; Raimbourg, J.; Rousseau, A. [CEA-DAM Ile de France, Bruyères-le-Châtel, 91297 Arpajon Cedex (France); and others

    2016-03-15

    The Laser Megajoule (LMJ) facility located at CEA/CESTA started to operate in the early 2014 with two quadruplets (20 kJ at 351 nm) focused on target for the first experimental campaign. We present here the first set of gated x-ray imaging (GXI) diagnostics implemented on LMJ since mid-2014. This set consists of two imaging diagnostics with spatial, temporal, and broadband spectral resolution. These diagnostics will give basic measurements, during the entire life of the facility, such as position, structure, and balance of beams, but they will also be used to characterize gas filled target implosion symmetry and timing, to study x-ray radiography and hydrodynamic instabilities. The design requires a vulnerability approach, because components will operate in a harsh environment induced by neutron fluxes, gamma rays, debris, and shrapnel. Grazing incidence x-ray microscopes are fielded as far as possible away from the target to minimize potential damage and signal noise due to these sources. These imaging diagnostics incorporate microscopes with large source-to-optic distance and large size gated microchannel plate detectors. Microscopes include optics with grazing incidence mirrors, pinholes, and refractive lenses. Spatial, temporal, and spectral performances have been measured on x-ray tubes and UV lasers at CEA-DIF and at Physikalisch-Technische Bundesanstalt BESSY II synchrotron prior to be set on LMJ. GXI-1 and GXI-2 designs, metrology, and first experiments on LMJ are presented here.

  20. Technical and economic practicability of novel flywheel mass storage systems in electricity supply networks; Technisch-wirtschaftliche Realisierbarkeit von neuartigen Schwungmassenspeicher-Systemen (SMSS) in elektrischen Netzen

    Energy Technology Data Exchange (ETDEWEB)

    Bornemann, H J; Baeumer, U; Kaiser, A; Gruener, A; Gutt, H J; Hampel, R; Heyder, B; Kleimaier, M; Radtke, U; Sachse, H; Schlechter, V; Schrepfer, W; Worlitz, F

    1998-12-31

    Efficient storage of electrical energy is an increasing need. New developments in high-power electronics, high-strength materials and magnetic bearings have made efficient reliable flywheel mass storage systems in the range of 1-5 MfW/50-150 kWh conceivable. According to a first assessment, these systems may provide energy to the supply grid in a range of seconds and thus ensure frequency maintenance and compensation of short interruptions. The authors present first results of a preliminary study preparatory to a feasibility study on the technical and economic practicability of flywheel mass storage systems. (orig.) [Deutsch] Das Thema effiziente Speicherung von elektrischer Energie gewinnt immer mehr an Bedeutung. Durch neuere Entwicklungen in der Leistungselektronik und bei der Herstellung hochfester Werkstoffe sowie durch Fortschritte bei der Entwicklung von beruehrungsfreien Lagern im Bereich der aktiven Magnetlager (AML) und insbesondere supraleitenden Magnetlager (SML) sind effiziente und sichere Schwungmassenspeicher-Systeme (SMSS) bis in die Bereiche 1-5 MW/50-150 kWh denkbar. Nach einer ersten Einschaetzung eignen sich solche Anlagen, um im Sekundenbereich Energie in das Netz abzugeben und somit zur Frequenzstuetzung und zur Kompensation von Kurzunterbrechungen beizutragen. Praesentiert werden erste Ergebnisse einer Untersuchung zur Vorbereitung einer Machbarkeitsstudie ueber die technisch-wirtschaftliche Realisierbarkeit von Schwungmassenspeicher-Systemen. (orig.)

  1. 32. MPA seminar 2006. Lectures; 32. MPA Seminar 2006. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This conference CD contains the full text of 47 papers on the following subjects: 1. Ageing management; 2. Integrity analysis; 3. Materials engineering; 4. State monitoring; 5. Pressure equipment status monitoring; 6. Quality assurance; 7. Non-destructive testing; 8. Fracture-mechanical analysis of components. [German] Diese Tagungs-CD enthaelt den Text von 47 Vortraegen mit folgenden Themenschwerpunkten: 1. Alterungsmanagement; 2. Integritaetsanalyse; 3. Werkstofftechnik; 4. Zustandsueberwachung; 5. Beschaffenheit Druckgeraete; 6. Qualitaetssicherung; 7. Zerstoerungsfreie Pruefung; und 8. Bruchmechanische Bauteilanalyse.

  2. Physikalische Therapie der Beckenbodeninsuffizienz - Methodenvergleich

    Directory of Open Access Journals (Sweden)

    Bocker B

    2002-01-01

    Full Text Available Harninkontinenz wird von der Internationalen Gesellschaft für Kontinenz als soziales und hygienisches Problem durch unwillkürlichen Harnverlust definiert [1]. Um Aussagen über die Wirksamkeit einzelner Therapieformen in der Behandlung dieser Erkrankung treffen zu können, untersuchten wir 24 Patientinnen mit neuromuskulärer Beckenbodenschwäche sowie 24 männliche Patienten nach Prostatektomie. In einer kontrollierten, prospektiven Längsschnittstudie erhielten je 8 Patienten jeder Diagnosegruppe nach randomisierter Zuordnung eine Serie Elektrostimulation der Beckenbodenmuskulatur (ES, Biofeedbacktherapie (BF und EMG-getriggerte Elektrostimulation (EMG-ES in Kombination mit einer standardisierten Krankengymnastik (KG. Hauptzielparameter ist der Harninkontinenzgrad, Nebenzielparameter die Häufigkeit der Inkontinenzepisoden und Beckenbodenspannung, gemessen über den Oberflächen-EMG-Bereich. In bezug auf den Harninkontinenzgrad sind die Ergebnisse am Studienende bei Einsatz der Feedbackverfahren signifikant besser als nach isolierter Elektrostimulation. Durch BF sank der Harninkontinenzgrad nach Ingelmann-Sundberg im Mittelwert von Therapiebeginn bis zum Ende des Follow-up um 1,2; nach EMG-ES um 1,05. Passive ES führte zu einer Harninkontinenzreduktion um 0,36. In der Beeinflussung der Inkontinenzepisoden ist die bessere Wirkung der Biofeedbackverfahren im Follow-up gesichert (Häufigkeit / d von 2,5 auf 0,75 gegenüber einer Abnahme von 2,6 auf 1,9 infolge ES. Bezüglich des EMG-Bereiches zeigt die reine Elektrostimulation im Gegensatz zu den Feedback-gekoppelten Verfahren (Zunahme der Aktivität um 13,6 bzw. 12 µV keine Wirkung auf die Muskelaktivität. Bei isolierter Betrachtung der Diagnosegruppen führt reine Biofeedbackbehandlung bei den prostatektomierten Patienten zur Abnahme der Harninkontinenz über das Therapieende hinaus: MV = 2,0 bei SD = 0,17 zu Beginn auf MV = 0,7 bei SD = 0,14 zwölf Wochen nach Therapie. Dagegen hat EMG-getriggerte Elektrostimulation des Beckenbodens den nachhaltigeren Effekt auf den Harninkontinenzgrad der Patientinnen mit Postpoliosyndrom (MV = 1,6 bei SD = 0,49 zu Beginn bis MV = 0 bei SD = 0 zwölf Wochen nach Therapie. Es ist anzunehmen, daß bei operierten Patienten die Wiedereingliederung der Beckenbodenmuskulatur in ein kontinenzerhaltendes Muskelzusammenspiel mittels Biofeedback-unterstützter Krankengymnastik effizient ist, wogegen bei neurogener Muskelschwäche zusätzlich eine EMG-abhängige Elektrostimulation zur Funktionsverbesserung erforderlich ist.

  3. 8 October 2013 - Rolex Director- General G. Marini in the ATLAS Control Room with CERN Director-General R. Heuer and ATLAS Collaboration Senior Physicist C. Rembser; visiting the ATLAS experimental cavern at LHC Point 1. Were also present from the Directorate: S. Lettow, Director for Administration and General Infrastructure; from the ATLAS Collaboration: Technische Universitaet Dortmund (DE) J. Jentzsch and SLAC National Accelerator Laboratory (US) G. Piacquadio.

    CERN Multimedia

    Anna Pantelia

    2013-01-01

    8 October 2013 - Rolex Director- General G. Marini in the ATLAS Control Room with CERN Director-General R. Heuer and ATLAS Collaboration Senior Physicist C. Rembser; visiting the ATLAS experimental cavern at LHC Point 1. Were also present from the Directorate: S. Lettow, Director for Administration and General Infrastructure; from the ATLAS Collaboration: Technische Universitaet Dortmund (DE) J. Jentzsch and SLAC National Accelerator Laboratory (US) G. Piacquadio.

  4. CHP biomass gasifier for the Zwarts Gerbera Nursery. Technical and economic feasibility; Biomassavergasser-WKK voor Gerberakwekerij Zwarts. Technische inpassing en economische haalbaarheid

    Energy Technology Data Exchange (ETDEWEB)

    Peeters, S.; Hart, A. [Energy Matters, Driebergen (Netherlands)

    2011-10-15

    when we factor in the renewable energy subsidy (SDE+) and investment subsidies such as MEI and EIA. Assuming the cheaper 800 kWe installations, the SDE+ subsidy of euro 90/MWh, current wood chipping prices and co-burning of cheaper residual waste such as reed, the payback time is 3 to 4 years. If the biomass can be contracted for 4 to 5 years at a fixed price, then an investment in a CHP gasifier is definitely an interesting alternative to the current gas CHP installations within the horticulture sector. This feasibility study assumes that the horticulturer's biomass costs are euro 35/tonne for a wood and reed mixture (87.5% and 12.5% respectively) and euro 40/tonne for 100% wood chippings, including transport. This assumes euro 25/tonne reed removal costs for the supplier, the province of Utrecht, Natuurmonumenten and/or the Forestry Commission (Staatsbosbeheer). In this case these parties do not pay euro 35/tonne for the processing of the waste by a green waste collector. The horticulturer receives euro 10/tonne for buying the reed, which offsets part of his investment risk. The cheap reed thus makes a significant contribution to the profitability of the installation. However, there is insufficient reed in the province of Utrecht to meet the total energy requirement of the Zwarts nursery, let alone for more energy projects. Moreover, the placement of the installation is subject to an Area Exploitation (WABO) Permit and the implementation of several measures. The installation is feasible in the current situation, both in terms of placement, technical compatibility and logistics, the supply of biomass and the removal of combustion ash [Dutch] Dit rapport beschrijft de haalbaarheid van een vergasser-WKK-installatie bij Gerberakwekerij Zwarts. Met behulp van de inzichten van dit onderzoek is een beeld geschetst voor energieproductie middels vergassing in de tuinbouwsector. Let wel, elk gewas kent zijn specifieke groeibehoeften, nutriënten, warmte/koude, licht, maar

  5. Safety characteristics. Vol. 1. Combustible liquids and gases; Sicherheitstechnische Kenngroessen. Bd. 1. Brennbare Fluessigkeiten und Gase

    Energy Technology Data Exchange (ETDEWEB)

    Brandes, E.; Moeller, W. [Laboratorium ' Sicherheitstechnische Kenngroessen' , Braunschweig (Germany)

    2003-07-01

    This reference manual is based on the 2002 version of the CHEMSAFE database, which is produced since 1989 by the PTB (Physikalisch-Technische Bundesanstalt), the BAM (Bundesanstalt fuer Materialforschung und -pruefung) and the DECHEMA (Gesellschaft fuer Chemische Technik und Biotechnologie e.V.). About 1,900 combustible gases and vapours are listed, along with explosion protection characteristics like flame point, ignition temperature, explosion limits, minimum ignition energy, normal gap width, maximum explosion pressure, and maximum pressure increase over time. Important thermophysical data are presented as well, e.g. boiling temperature, vapour pressure as a function of temperature, melting temperature, and density. Definitions of the characteristics are presented. There are several indexis to facilitate acces (CAS number, sum formula, synonyms). [German] Anwender in Industrie, Handel, Handwerk und Behoerden benoetigen verlaessliche Daten, von Fachleuten bewertete Kenngroessen des Brand- und Explosionsschutzes, um Brand- und Explosionsgefahren beim Verarbeiten, Abfuellen, Lagern, Befoerdern und Entsorgen brennbarer Stoffe beurteilen und angemessene Schutzmassnahmen ergreifen zu koennen. Die 1989 gemeinsam mit der Bundesanstalt fuer Materialfoschung und -pruefung (BAM) und der Gesellschaft fuer Chemische Technik und Biotechnologie e.v (DECHEMA) erstellte Datenbank CHEMSAFE diente als Grundlage dieses Nachschlagewerkes. Die hier bei Drucklegung wiedergegebenen Kenngroessen entsprechen dem Update 2002 der Datenbank CHEMSAFE. Etwa 1.900 brennbare Gase und Daempfe, Kenngroessen des Explosionsschutzes wie Flammpunkt, Zuendtemperatur, Explosionsgrenzen, Mindestzuendenergie, Normspaltweite, maximaler Explosionsdruck und maximaler zeitlicher Druckanstieg sind ebenso aufgelistet wie auch einige wichtige thermophysikalische Groessen wie Siedetemperatur, Dampfdruck als Funktion der Temperatur, Schmelztemperatur und Dichte. Die Angaben werden eingeleitet durch Definitionen

  6. Lessons learnt from an international intercomparison of national network systems used to provide early warning of a nuclear accident

    International Nuclear Information System (INIS)

    Saez-Vergara, J.C.; Thompson, I.M.G.; Funck, E.; Andersen, C.E.; Neumaier, S.; Botter-Jensen, L.

    2003-01-01

    As part of the European Research Council's Fourth Framework Programme, the EURADOS Action Group on Monitoring of External Exposures held an intercomparison of national network systems. This took place during May/June 1999 at the Riso Natural Environmental Radiation Measurement Station in Denmark and at the Underground Laboratory for Dosimetry and Spectrometry of the Physikalisch-Technische Bundesanstalt in Germany. The network systems are used continuously to monitor radiation levels throughout a country in order to give early warning of nuclear accidents having transboundary implications. The radiation levels measured are used to estimate the radiation risks to people arising from the accident. Seven European countries participated in the intercomparison with detector systems used in their national network systems as well as with detectors being developed for future use. Since different radiation quantities were measured by the systems (namely exposure, air kerma and ambient dose equivalent), the initial analysis of the intercomparison results was made in terms of the quantity air kerma rate. This report completes the analysis of the results and these are given in terms of air kerma rate in order to be consistent with the preliminary report. In addition, in some cases the results are also given in terms of the quantity measured by each national network system. The experience gained from this intercomparison is used to help organise a follow-up intercomparison to be held at the PTB Braunschweig in September 2002 and in which a further seven or eight countries from Europe will participate. (author)

  7. The high-resolution extraterrestrial solar spectrum (QASUMEFTS determined from ground-based solar irradiance measurements

    Directory of Open Access Journals (Sweden)

    J. Gröbner

    2017-09-01

    Full Text Available A high-resolution extraterrestrial solar spectrum has been determined from ground-based measurements of direct solar spectral irradiance (SSI over the wavelength range from 300 to 500 nm using the Langley-plot technique. The measurements were obtained at the Izaña Atmospheric Research Centre from the Agencia Estatal de Meteorología, Tenerife, Spain, during the period 12 to 24 September 2016. This solar spectrum (QASUMEFTS was combined from medium-resolution (bandpass of 0.86 nm measurements of the QASUME (Quality Assurance of Spectral Ultraviolet Measurements in Europe spectroradiometer in the wavelength range from 300 to 500 nm and high-resolution measurements (0.025 nm from a Fourier transform spectroradiometer (FTS over the wavelength range from 305 to 380 nm. The Kitt Peak solar flux atlas was used to extend this high-resolution solar spectrum to 500 nm. The expanded uncertainties of this solar spectrum are 2 % between 310 and 500 nm and 4 % at 300 nm. The comparison of this solar spectrum with solar spectra measured in space (top of the atmosphere gave very good agreements in some cases, while in some other cases discrepancies of up to 5 % were observed. The QASUMEFTS solar spectrum represents a benchmark dataset with uncertainties lower than anything previously published. The metrological traceability of the measurements to the International System of Units (SI is assured by an unbroken chain of calibrations leading to the primary spectral irradiance standard of the Physikalisch-Technische Bundesanstalt in Germany.

  8. Upgrading the Medical Physics Calibration Laboratory Towards ISO/IEC 17025: Radiation Standards and Calibration in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Muhammad Jamal Md Isa; Abd Aziz Mhd Ramli; Wan Hazlinda Ismail; Norhayati Abdullah; Shahrul Azlan Azizan; Siti Sara Deraman; Nor Azlin Azraai; Md Khairusalih Md Zin

    2010-01-01

    Calibration of quality control (QC) test tools used in diagnostic radiology is legally required under the Ministry of Health (MOH) requirement. The Medical Physics Calibration Laboratory of the Malaysian Nuclear Agency is the national focal point for the calibration of quality control test tools used in diagnostic radiology. The Medical Physics Calibration Laboratory has measurement traceability to primary standard dosimetry laboratory (Physikalisch-Technische Bundesanstalt (PTB)), thus providing an interface between the primary standard dosimetry laboratory and Malaysian hospitals, clinics and license class H holder. The Medical Physics Calibration Laboratory facility is comprised of a constant potential x-ray system with a capability of 160 kV tube and a series of reference and working standard ion chambers. The stability of reference and working standard ion chambers was measured using strontium-90. Dosimetric instruments used in diagnostic radiology is calibrated in terms of air kerma to comply with an International Code of Practices of dosimetry for example IAEA's Technical Report Series number 457. The new series of standard radiation qualities was established based on ISO/IEC 61267. The measurement of beam homogeneity was measured using film and ion chamber to define the field size at certain distance and kV output was measured using the spectrometer and non-invasive kVp meter. The uncertainties measurement was determined with expended uncertainties to a level of confidence of approximately 95% (coverage factor k=2). This paper describes the available facility and the effort of the Medical Physics Calibration Laboratory to upgrade the laboratory towards ISO/IEC 17025. (author)

  9. Dose measurements in pulsed radiation fields with commercially available measuring components

    International Nuclear Information System (INIS)

    Friedrich, Sabrina; Hupe, Oliver

    2016-01-01

    Dose measurements in pulsed radiation fields with dosemeters using the counting technique are known to be inappropriate. Therefore, there is a demand for a portable device able to measure the dose in pulsed radiation fields. As a detector, ionisation chambers seem to be a good alternative. In particular, using a secondary standard ionisation chamber in combination with a reliable charge-measuring system would be a good solution. The Physikalisch-Technische Bundesanstalt (PTB) uses secondary standard ionisation chambers in combination with PTB-made measuring electronics for dose measurements at its reference fields. However, for general use, this equipment is too complex. For measurements on-site, a mobile special electronic system [Hupe, O. and Ankerhold, U. Determination of ambient and personal dose equivalent for personnel and cargo security screening. Radiat. Prot. Dosim. 121(4), 429-437 (2006)] has been used successfully. Still, for general use, there is a need for a much simpler but a just as good solution. A measuring instrument with very good energy dependence for H*(10) is the secondary standard ionisation chamber HS01. An easy-to-use and commercially available electrometer for measuring the generated charges is the UNIDOS by PTW Freiburg. Depending on the expected dose values, the ionisation chamber used can be selected. In addition, measurements have been performed by using commercially available area dosemeters, e.g. the Mini SmartION 2120S by Thermo Scientific, using an ionisation chamber and the Szintomat 6134 A/H by Automess, using a scintillation detector. (authors)

  10. Textbook on X-ray diagnostics. Substantiated by Marianne Zimmer-Brossy. 6. new rev. ed.; Lehrbuch der roentgendiagnostischen Einstelltechnik. Begruendet von Marianne Zimmer-Brossy

    Energy Technology Data Exchange (ETDEWEB)

    Becht, Stefanie [Unfallkrankenhaus Berlin (Germany). Inst. fuer Radiologie; Bittner, Roland C. [Helios Klinikum Emil von Behring, Berlin (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Ohmstede, Anke [Klinikum Oldenburg gGmbH (Germany). MTA-Schule; Pfeiffer, Andreas [Klinikum Stuttgart (Germany). Servicecenter Informationstechnik; Rossdeutscher, Reinhard [Johanniter-Krankenhaus im Flaeming, Treuenbrietzen (Germany). Abt. fuer Roentgendiagnostik

    2008-07-01

    The standard textbook on x-ray diagnostics has been revised by the MTRA team and radiologists: The book covers the following topics: General information: the profession of a radiologist, the x-ray department, radiation protection, quality assurance, basic physics, x-ray imaging, analog and digital image processing, archives, image interpretation. Skeleton diagnostics; Inner organs (thorax organs, neck, abdomen, gastrointestinal tract, colon, gall bladder and biliary tract): Special x-ray diagnostic methods: x-ray diagnostic of the female and male chest, x-ray diagnostics of bone joints (arthrography, and contrast media), x-ray diagnostics of the urinary-genital system, x-ray diagnostics of cavities and syrinx, x-ray diagnostics of arteries (arteriography, angiography), percutaneous transluminal angioplasty, x-ray diagnostics of veins (phlebography), x-ray diagnostics of lymphatic vessels and lymph nodes, x-ray diagnostics of spinal cord (myelography); Specific imaging methods: computerized tomography. [German] Ein erfahrenes Team aus MTRA und Radiologen ueberarbeitete und verbesserte das bewaehrte Standardwerk grundlegend. Detailliert, praezise und ausfuehrlich erlaeutert die 6. Neuauflage technische und physikalische Grundlagen, Strahlenschutz, alle wichtigen Einstellungen (vom Skelettsystem bis hin zur Mammadiagnostik) und aktuelle Leitlinien. Nah an der Praxis sind insbesondere die Hinweise zur Patientenvorbereitung und -lagerung, Qualitaetskriterien und Bildmerkmale sowie viele Tipps und Checklisten. Alle Einstellbilder sowie die Mehrzahl der radiologischen Aufnahmen sind erneuert. Die Kapitel zur digitalen Radiographie und den Grundlagen der MRT sind neu, die Kapitel zu CT-Protokollen und zur interventionellen Radiologie erweitert. Ein ausfuehrliches Glossar rundet das Buch ab. Insgesamt ein wertvolles und unverzichtbares Standardwerk fuer Ausbildung und Beruf. (orig.)

  11. The X-ray response of TlBr

    International Nuclear Information System (INIS)

    Owens, Alan; Bavdaz, M.; Brammertz, G.; Gostilo, V.; Graafsma, H.; Kozorezov, A.; Krumrey, M.; Lisjutin, I.; Peacock, A.; Puig, A.; Sipila, H.; Zatoloka, S.

    2003-01-01

    We present the results of a series of X-ray measurements on several prototype TlBr detectors. The devices were fabricated from mono-crystalline material and were typically of size 2.7x2.7x0.8 mm 3 . The material is extremely pure, having impurity concentrations -4 and 1x10 -5 cm 2 V -1 , respectively, which are about an order of magnitude higher than previously reported values. Three detectors were fabricated and extensively tested over the energy range 2.3-100 keV at three synchrotron radiation facilities: the Physikalisch-Technische Bundesanstalt (PTB) laboratory at the Berliner Elektronenspeicherring fuer Synchrotronstrahlung (BESSY II), the European Synchrotron Radiation Research Facility (ESRF) and the Hamburger Synchrotron-strahlungslabor (HASYLAB) radiation facility. Room temperature energy resolutions under full-area illumination of 1.8 and 3.3 keV FWHM have been achieved at 5.9 and 59.95 keV, respectively. At reduced detector temperatures of -30 deg. C, these fall to 800 eV and 2.6 keV FWHM, respectively. Under monochromatic pencil beam illumination, the measured energy resolutions at 6 and 60 keV were 664 eV and ∼3 keV FWHM at the same temperature. For energies 2 , 12 keV mono-energetic X-ray beam, raster scanned over the forward active area. Whilst two detectors were spatially uniform to a level commensurate with statistics, the third was not. In all cases, evidence was found for charge collection problems caused by field fringing

  12. Dual vehicle - Development, construction and testing of a dual vehicle for passenger transport on roads and railways. Final report; Zweiwegefahrzeug - Entwicklung, Bau und Erprobung eines Zweiwegefahrzeuges zur Personenbefoerderung Strasse/Schiene. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This feasibility study investigated a prototype dual vehicle for railways and roads. Technical problems, acceptance specifications, legal and economic aspects were gone into. [German] Zielstellung fuer das Vorhaben war die Untersuchung ausgewaehlter technischer Fragestellungen hinsichtlich der Machbarkeit der Entwicklung und Erprobung eines Prototypes fuer ein Zweiwegefahrzeug fuer den Personenverkehr, das fuer den Einsatz auf der Schiene und der Strasse vorgesehen und dafuer entsprechend technisch ausgestattet ist. Damit erbringt das Vorhaben technisch-konstruktive Loesungsansaetze fuer ein vollstaendig neues Fahrzeuggrundkonzept und traegt hinsichtlich eines solchen zukuenftigen Fahrzeugtyps - zur Klaerung technischer Fragen (statische Zusammenbauuntersuchungen, geometrische und massliche Bedingungen sowie Konzipierung, Leistungsanforderungen der Komponenten, Konzept fuer Ein- und Ausspuren sowie fuer Ein- und Ausstieg), - zur Pruefung der technischen Zulassungsfaehigkeit des Fahrzeuges, - zur Klaerung von Rechtsfragen fuer die Sicherung des Betriebes des Fahrzeuges - sowie zum Nachweis des wirtschaftlicheren Betriebes des Fahrzeuges bei. Das Vorhaben unterbreitet unter Beruecksichtigung sicherheitstechnischer, gesetzlicher und wirtschaftlicher Rahmenbedingungen Loesungsvorschlaege fuer die konstruktive Konzipierung des Fahrgestells und ein technisches Konzept fuer das Ein- und Ausspuren fuer einen neuen Fahrzeugtyp, der sowohl fuer die Strassenbenutzung als auch fuer den Schienenverkehr zugelassen ist. (orig.)

  13. Non-metals in metals `98; Nichtmetalle in Metallen `98

    Energy Technology Data Exchange (ETDEWEB)

    Hirschfeld, D. [ed.

    1998-12-31

    The major topics discussed at the symposium are: (1) Thermodynamics and cinetics, (2) chemical, physical and physico-chemical examination methodology, (3) materials properties. 13 of the 25 papers presented at the symposium have been analysed and indexed for separate retrieval from the database. (orig./CB) [Deutsch] Themenschwerpunkte des diesjaehrigen Symposiums `Nichtmetalle in Metallen` sind: 1. Thermodynamik und Kinetik, 2. Chemische, physikalische und physikalisch-chemische Untersuchungsmethoden, und 3. Werkstoffeigenschaften. Von den insgesamt 25 Vortraegen wurden 13 Beitraege separat aufgenommen. (orig./MM)

  14. Integral Building Design workshops : a concept to structure communication

    NARCIS (Netherlands)

    Savanovic, P.; Zeiler, W.; Tzou, H.S.; Jalili, N.

    2007-01-01

    Following the developments in (Dutch) building practice, where besides specialist skills a design approach is increasingly being asked, the Building Services chair of the Faculty of Architecture, Building and Planning of Technische Universiteit Eindhoven (TU/e) initiated in academic year 2005/06 a

  15. Architecture of instruction and delight : a socio-historical analysis of World Exhibitions as a didactic phenomenon (1798-1851-1970)

    NARCIS (Netherlands)

    Wesemael, van P.J.V.

    2001-01-01

    Vert. en bew. van het proefschrift Technische Universiteit Delft: Architectuur van instructie en vermaak : een maatschappij-historische analyse van de wereldtentoonstelling als didactisch verschijnsel (1798-1851-1970). - Delft : Publicatiebureau Bouwkunde, Faculteit der Bouwkunde, Technische

  16. 2015 Laser Diagnostics in Combustion Gordon Research Conference and Gordon Research Seminar

    Science.gov (United States)

    2015-10-20

    Lewis College Poster Presenter Registered Pareja Restrepo, Jhon Alexander Technische Universitaet Darmstadt Poster Presenter Registered...Registered O’Hagan, Seamus K University of Oxford Poster Presenter Registered Pareja Restrepo, Jhon Alexander Technische Universitaet Darmstadt

  17. Blades and disks in gas turbines. Material and component behaviour. Project department D. Final report; Schaufeln und Scheiben in Gasturbinen. Werkstoff- und Bauteilverhalten. Projektbereich D. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-04-01

    The Special Research Department No. 339, ``Disks and Blades in Gas Turbines - Material and Component Characteristics`` received financial support from 1988 through 1996. This final report discusses activities of the years 1994, 1995, and 1996. Project group D, ``Production and Quality Assurance``, investigated rotors and blades. Grinding techniques were developed and optimized for nickel base materials, and the effects of grinding on the marginal zones was investigated, including an analysis of intrinsic stresses induced by machining. In the field of ceramics, separation and production of reinforced ceramics was investigated, and techniques for vacuum soldering of ceramic/ceramic and ceramic/metal compounds for high-temperature applications were developed. In the framework of a part-project carried out at HMI, neutron diffraction was used for nondestructive analysis of volume intrinsic stresses near the joint both on model geometries and on the joint between metal shaft and ceramic rotor. The development and application of computerized tomography for testing of ceramic rotors and joints was an important contribution to quality assurance. (orig./MM) [Deutsch] Der Sonderforschungsbereich 339 `Schaufeln und Scheiben in Gasturbinen - Werkstoff- und Bauteilverhalten` wurde von 1988 bis Ende 1996 gefoerdert. Der vorliegende Abschlussbericht behandelt vor allem die Arbeiten der Jahre 1994, 1995 und 1996. Am Bauteil Rotor und Schaufel orientierten sich die Arbeiten des Projektbereichs D `Fertigung und Qualitaetssicherung`. Zum einen wurden hier Schleifverfahren fuer Nickelbasis-Werkstoffe entwickelt und optimiert und der Einfluss der Schleifbearbeitung auf die Randzoneneigenschaften studiert. Zur Randzonencharakterisierung gehoerte insbesondere auch die Analyse bearbeitungsinduzierter Eigenspannungen. Auf der Seite der Keramiken wurde zum einen die trennende Fertigung verstaerkter Keramiken untersucht. Zum anderen wurden Techniken fuer das Hochvakuumloeten von Keramik

  18. Specification of a technically justified limiting value for sulphur concentrations in heating oil in order to enhance the use of high-efficiency boiler technology in oil heating systems; Ermittlung eines technisch begruendeten Grenzwertes fuer Schwefelgehalte im Heizoel zur Foerderung des Einsatzes von Brennwerttechnologie in Oelheizungsanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bellingen, E.-M.; Kuechen, C. [Institut fuer Wirtschaftliche Oelheizung e.V., Hamburg (Germany); Haase, F.; Wilckens, H. [Deutsche Shell AG, Hamburg (Germany); Sinnen, H.D. [VEBA AG, Duesseldorf (Germany)

    2002-04-01

    Different oil condensing boilers, which were available on the German market, have been investigated in order to determine the relevant limit for sulphur content in domestic heating oil. Up to now, the condensate from oil condensing boilers has to be neutralized in many cases due to local legislation. The composition of the condensates from oil boilers came out to be similar to the condensate from gas condensing boilers, as long as the sulphur content of heating oil is below 100 mg/kg. As the neutralization of condensate from gas condensing boilers is usually not required up to 200 kW-boilers, there should be no technical reason for neutralization, as long as the sulphur content is below 100 mg/kg. However, boiler manufactures are convinced, that only if the sulphur content is as low as 50 mg/kg, it will be possible to develop reliable oil condensing boilers for a reasonable price. Calculations of the total energy consumption came to the result, that primary energy can be saved. The increase of efficiency on the boiler side has more influence than the energy needed for desulphurization. (orig.) [German] Zur Bestimmung eines technisch begruendeten Schwefelgrenzwertes fuer ein neues 'schwefelarmes' Heizoel EL wurden Untersuchungen mit Heizoelen unterschiedlichen Schwefelgehaltes an verschiedenen auf dem Markt verfuegbaren Oelbrennwertgeraeten durchgefuehrt. Zur Zeit wird durch das ATV Arbeitsblatt A-251 eine Neutralisation von Kondensaten aus Oelbrennwertanlagen gefordert. Die Untersuchungen zeigen, dass bei Schwefelgehalten unter 100 mg/kg die Kondensate aehnliche Zusammensetzungen aufweisen wie Kondensate aus Gasbrennwertgeraeten. Die Voraussetzung fuer eine Befreiung von der Neutralisationsverpflichtung bei der Verwendung dieser Brennstoffe ist damit aus technischer Sicht gegeben. Fuer die Entwicklung von neuen, kompakten und preiswerten Oelbrennwertgeraeten wird von der Heizgeraeteindustrie ein Schwefelgehalt von max. 50 mg/kg fuer notwendig gehalten

  19. Investigation and modelling of fuel utilisation in the zone near the burner of technical combustion systems. Final report; Untersuchung und Modellierung der Brennstoffumsetzung im Brennernahbereich technischer Verbrennungssysteme. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kremer, H.; Wirtz, S.

    1999-06-01

    Optimisation and development of technical combustion systems in order to generate energy efficiently and reduce pollution is an ever-increasing challenge. Mathematical and numerical simulations play a very important role in this context. This project was dedicated to the implementation and improvement of mathematical models and subsequent verification of the modelling concepts. Verification used data measured by the university department for combined cyle turbines. The focal point of interest was the reaction zone near the burner. Further points of interest: development and improvement of models for two-phase effects, fuel consumption and turbulence interaction as well as further development of the methods of numerical simulation. Simulating the combustion chamber of the combined cycle turbines was prioritised.(orig.) [German] Die Optimierung und Weiterentwicklung technischer Verbrennungssysteme mit dem Ziel einer moeglichst effizienten und schadstoffarmen Energiebereitstellung stellt eine staendig wachsende Herausforderung dar. Bei der technologischen Umsetzung dieses Ziels kommt der mathematisch-numerischen Simulation eine immer groessere Bedeutung zu. In diesem Projekt sollte die Implementierung und Verbesserung von mathematischen Modellierungsansaetzen sowie die anschliessende Verifikation der Modellierungskonzepte anhand der Messdaten des Lehrstuhls fuer Dampf- und Gasturbinen (LDuG) durchgefuehrt werden. Der Schwerpunkt lag in der brennernahen Reaktionszone. Konkrete Arbeitsschwerpunkte waren die Weiterentwicklung und Verbesserung der Modellansaetze fuer Zweiphaseneffekte, Brennstoffumsatz und Turbulenzinteraktion sowie die Weiterentwicklung der Methodik der numerischen Simulation. Dabei stand die Simulation der Brennkammer des LDuG im Vordergrund. (orig.)

  20. Failure Models of Thin-walled Steel Sheeting and Structural-spatial Design Process

    NARCIS (Netherlands)

    Hofmeyer, H.

    2009-01-01

    This presentation is the first on 20 years of research on the failure mechanisms of sheeting subjected to combined concentrated load and bending moment, performed at Technische Universiteit Eindhoven. The aim of this research is to develop accurate, insight providing design rules using simple

  1. DARMSTADT: Superconducting electron accelerator in operation

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    In December, the S-DALINAC superconducting radiofrequency electron accelerator at the Nuclear Physics Institute of Darmstadt's Technische Hochschule was completed. This pioneer continuous-wave (c.w.) machine passed a major milestone several years ago when it accelerated its first low energy electron beam

  2. Development of service-relevant materials data and economic quality assurance and machining procedures for gas turbine blades. Final report; Entwicklung betriebsrelevanter Werkstoffkennwerte und wirtschaftlicher Qualitaetssicherungs- und Bearbeitungsverfahren fuer GT-Schaufeln. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Buergel, R.; Rechtenbacher, H.

    1994-01-01

    Schwingfestigkeit einstellen, die der des Udiment 720/GK entspricht? - Bietet die Feingussschaufel einen nennenswerten Preisvorteil gegenueber der Schmiedeschaufel, falls die technische Qualifikation erfuellt ist? Das Vorhaben hat entscheidend dazu beigetragen, die Beantwortung dieser Fragen vorzubereiten. (orig.)

  3. Effectiviteit van een klassieke Crew Resource Management training in de Intensive Care: een gecontroleerde studie.

    NARCIS (Netherlands)

    Kemper, P.F.; Bruijne, M. de; Dyck, C. van; So, K.L.; Tangkau, P.; Wagner, C.

    2013-01-01

    Achtergrond: Er is een toenemende bewustwording dat onbedoelde zorg gerelateerde schade in de gezondheidszorg vaker voortvloeit uit problemen met niet-technische vaardigheden, dan door een gebrek in technische, of klinische, vaardigheden. Dit is vooral van belang in de Intensive Care (IC), waar

  4. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV

    Science.gov (United States)

    Krauss, A.; Kapsch, R.-P.

    2018-02-01

    For the ionometric determination of the absorbed dose to water, D w, in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q, are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  5. Direct determination of k Q factors for cylindrical and plane-parallel ionization chambers in high-energy electron beams from 6 MeV to 20 MeV.

    Science.gov (United States)

    Krauss, A; Kapsch, R-P

    2018-02-06

    For the ionometric determination of the absorbed dose to water, D w , in high-energy electron beams from a clinical accelerator, beam quality dependent correction factors, k Q , are required. By using a water calorimeter, these factors can be determined experimentally and potentially with lower standard uncertainties than those of the calculated k Q factors, which are tabulated in various dosimetry protocols. However, one of the challenges of water calorimetry in electron beams is the small measurement depths in water, together with the steep dose gradients present especially at lower energies. In this investigation, water calorimetry was implemented in electron beams to determine k Q factors for different types of cylindrical and plane-parallel ionization chambers (NE2561, NE2571, FC65-G, TM34001) in 10 cm  ×  10 cm electron beams from 6 MeV to 20 MeV (corresponding beam quality index R 50 ranging from 1.9 cm to 7.5 cm). The measurements were carried out using the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. Relative standard uncertainties for the k Q factors between 0.50% for the 20 MeV beam and 0.75% for the 6 MeV beam were achieved. For electron energies above 8 MeV, general agreement was found between the relative electron energy dependencies of the k Q factors measured and those derived from the AAPM TG-51 protocol and recent Monte Carlo-based studies, as well as those from other experimental investigations. However, towards lower energies, discrepancies of up to 2.0% occurred for the k Q factors of the TM34001 and the NE2571 chamber.

  6. Determination of line profiles on nano-structured surfaces using EUV and x-ray scattering

    Science.gov (United States)

    Soltwisch, Victor; Wernecke, Jan; Haase, Anton; Probst, Jürgen; Schoengen, Max; Krumrey, Michael; Scholze, Frank; Pomplun, Jan; Burger, Sven

    2014-09-01

    Non-imaging techniques like X-ray scattering are supposed to play an important role in the further development of CD metrology for the semiconductor industry. Grazing Incidence Small Angle X-ray Scattering (GISAXS) provides directly assessable information on structure roughness and long-range periodic perturbations. The disadvantage of the method is the large footprint of the X-ray beam on the sample due to the extremely shallow angle of incidence. This can be overcome by using wavelengths in the extreme ultraviolet (EUV) spectral range, EUV small angle scattering (EUVSAS), which allows for much steeper angles of incidence but preserves the range of momentum transfer that can be observed. Generally, the potentially higher momentum transfer at shorter wavelengths is counterbalanced by decreasing diffraction efficiency. This results in a practical limit of about 10 nm pitch for which it is possible to observe at least the +/- 1st diffraction orders with reasonable efficiency. At the Physikalisch-Technische Bundesanstalt (PTB), the available photon energy range extends from 50 eV up to 10 keV at two adjacent beamlines. PTB commissioned a new versatile Ellipso-Scatterometer which is capable of measuring 6" square substrates in a clean, hydrocarbon-free environment with full flexibility regarding the direction of the incident light polarization. The reconstruction of line profiles using a geometrical model with six free parameters, based on a finite element method (FEM) Maxwell solver and a particle swarm based least-squares optimization yielded consistent results for EUV-SAS and GISAXS. In this contribution we present scatterometry data for line gratings and consistent reconstruction results of the line geometry for EUV-SAS and GISAXS.

  7. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  8. Benchmark experiment to verify radiation transport calculations for dosimetry in radiation therapy; Benchmark-Experiment zur Verifikation von Strahlungstransportrechnungen fuer die Dosimetrie in der Strahlentherapie

    Energy Technology Data Exchange (ETDEWEB)

    Renner, Franziska [Physikalisch-Technische Bundesanstalt (PTB), Braunschweig (Germany)

    2016-11-01

    Monte Carlo simulations are regarded as the most accurate method of solving complex problems in the field of dosimetry and radiation transport. In (external) radiation therapy they are increasingly used for the calculation of dose distributions during treatment planning. In comparison to other algorithms for the calculation of dose distributions, Monte Carlo methods have the capability of improving the accuracy of dose calculations - especially under complex circumstances (e.g. consideration of inhomogeneities). However, there is a lack of knowledge of how accurate the results of Monte Carlo calculations are on an absolute basis. A practical verification of the calculations can be performed by direct comparison with the results of a benchmark experiment. This work presents such a benchmark experiment and compares its results (with detailed consideration of measurement uncertainty) with the results of Monte Carlo calculations using the well-established Monte Carlo code EGSnrc. The experiment was designed to have parallels to external beam radiation therapy with respect to the type and energy of the radiation, the materials used and the kind of dose measurement. Because the properties of the beam have to be well known in order to compare the results of the experiment and the simulation on an absolute basis, the benchmark experiment was performed using the research electron accelerator of the Physikalisch-Technische Bundesanstalt (PTB), whose beam was accurately characterized in advance. The benchmark experiment and the corresponding Monte Carlo simulations were carried out for two different types of ionization chambers and the results were compared. Considering the uncertainty, which is about 0.7 % for the experimental values and about 1.0 % for the Monte Carlo simulation, the results of the simulation and the experiment coincide.

  9. Flow cytometry for intracellular SPION quantification: specificity and sensitivity in comparison with spectroscopic methods

    Directory of Open Access Journals (Sweden)

    Friedrich RP

    2015-06-01

    Full Text Available Ralf P Friedrich,1 Christina Janko,1 Marina Poettler,1 Philipp Tripal,1 Jan Zaloga,1 Iwona Cicha,1 Stephan Dürr,1,2 Johannes Nowak,3 Stefan Odenbach,3 Ioana Slabu,4 Maik Liebl,4 Lutz Trahms,4 Marcus Stapf,5 Ingrid Hilger,5 Stefan Lyer,1 Christoph Alexiou1 1Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine, University hospital Erlangen, 2Department of Otorhinolaryngology, Head and Neck Surgery, Section of Phoniatrics and Pediatric Audiology, University hospital Erlangen, Erlangen, 3Technische Universität Dresden, Chair of Magnetofluiddynamics, Measuring and Automation Technology, Dresden, 4Physikalisch-Technische Bundesanstalt Berlin, Berlin, 5Department of Radiology, Division of Diagnostic and Interventional Radiology, Experimental Radiology, University hospital Jena, Jena, Germany Abstract: Due to their special physicochemical properties, iron nanoparticles offer new promising possibilities for biomedical applications. For bench to bedside translation of superparamagnetic iron oxide nanoparticles (SPIONs, safety issues have to be comprehensively clarified. To understand concentration-dependent nanoparticle-mediated toxicity, the exact quantification of intracellular SPIONs by reliable methods is of great importance. In the present study, we compared three different SPION quantification methods (ultraviolet spectrophotometry, magnetic particle spectroscopy, atomic adsorption spectroscopy and discussed the shortcomings and advantages of each method. Moreover, we used those results to evaluate the possibility to use flow cytometric technique to determine the cellular SPION content. For this purpose, we correlated the side scatter data received from flow cytometry with the actual cellular SPION amount. We showed that flow cytometry provides a rapid and reliable method to assess the cellular SPION content. Our data also demonstrate that internalization of iron oxide nanoparticles in human

  10. Quality assurance for the incorporation surveillance in Germany; Qualitaetssicherung fuer die Inkorporationsueberwachung in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Werner; Gerstmann, Udo; Hartmann, Martina; Loescher, Simone; Meisenberg, Oliver; Woidy, Patrick [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). FB Strahlenschutz und Gesundheit

    2017-08-01

    The coordination center of the Bundesamt fuer Strahlenschutz is performing annual ring experiments for in-vivo and in-vitro measuring points. This procedure allows checking the measuring data and the competence of the personnel. In the last years these tests included also radionuclides that are important in radiation emergency protection. Case studies for dose determination based on incorporation scenarios are included.

  11. Physikalische Belastungen in unseren Arbeits- und Umwelten

    DEFF Research Database (Denmark)

    Vogt, Joachim

    2004-01-01

    electromagnitic fields, information load, information policy, noise, physical stress, radiation, work-life balance......electromagnitic fields, information load, information policy, noise, physical stress, radiation, work-life balance...

  12. Passive house progress report: Energy and indoor air quality. Measuring methods and verification of energy saving potentials and indoor air quality in passive houses at Nuremberg; Passivhaus-Projektbericht: Energie und Raumluftqualitaet. Messetchnische Evaluierung und Verifizierung der energetischen Einsparpotentiale und Raumluftqualitaet an Passivhaeusern in Nuernberg. Projekt: Passiv-Haus-Doppelhaeuser, Wachtelstrasse 12/Praelat-Nicol-Strasse 3-7, Nuernberg-Wetzendorf

    Energy Technology Data Exchange (ETDEWEB)

    Schulze Darup, B [ed.

    2002-07-01

    A model passive building was constructed at Nuremberg. Buildings of this type have an annual heat consumption of less than 15 kWh/m{sup 2}, so that quality assurance is of utmost importance with regard to energy consumption, primary energy balance, environmental impact and especially room air quality. The findings of the project will be published. [German] Im Rahmen der Lokalen Agenda 21 wurde in Nuernberg ein Passivhaus-Modellprojekt erstellt. Da energiesparende Wohngebaeude mit einem jaehrlichen Heizwaermebedarf unter 15 kWh/m{sup 2} zunehmend zum Stand der Technik werden, ist eine grundlegende Qualitaetssicherung hinsichtlich Energieverbrauch, Primaerenergiebilanz, Umweltvertraeglichkeit und insbesondere Raumluftqualitaet sowie die Veroeffentlichung der Erfahrungen von grosser Bedeutung. (orig.)

  13. Site investigations and conceptual design for the repository in the nuclear 'Entsorgungszentrum' of the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Roethemeyer, H.

    1980-01-01

    Site investigations are planned to enable the Physikalisch-Technische Bundesanstalt and the other institutions involved to scrutinize the suitability of the Gorleben site and its salt dome as the nuclear 'Entsorgungszentrum' repository, and to provide all data necessary for detailed site-specific planning and safe building and operation of the repository. The investigations include deep drillings and an extensive hydrogeological programme for exploring the general structure of the salt dome and its environment. The latter programme started on 17 April 1979. The Bundesanstalt fuer Geowissenschaften und Rohstoffe (Federal Geological Survey) is in charge of the geoscientific side of the investigations. For the site-independent conceptual design the following requirements have been laid down: (1) for safety reasons retrievability is not to be considered; (2) standard mining techniques and the special experience gained at the Asse salt mine should be utilized as much as possible; (3) two shafts should be sufficient for the mine, for all transport and the ventilation system; (4) different forms of waste in terms of waste type and container shall be disposed of in different storage areas; (5) ventilated sections must permit the shutting off of each storage area from the rest of the mine; (6) the mining method of retreat working should be applied in order to explore the whole disposal area prior to the beginning of disposal, to enable an optimal fit of the mine to the structure of the salt dome, and to move away from the heat generated by heat-producing waste; (7) the mine works shall have a lateral safety distance to the cap rock of 200 m and a vertical safety zone of 300 m beneath the salt level. (8) all disposal areas shall be on one level; (9) salt and waste shall be transported in different drifts, mainly in a one-way system. (author)

  14. Characterization of a traceable profiler instrument for areal roughness measurement

    International Nuclear Information System (INIS)

    Thomsen-Schmidt, P

    2011-01-01

    A two-dimensional profiler instrument was designed and realized at the PTB (Physikalisch-Technische Bundesanstalt). The main function of the instrument is to provide traceable results in the field of roughness measurement. It is equipped with a linear moving stylus which is guided by precision air bearings. The moving part of the stylus has weight around 1 g and is carried by a magnetic field. The contacting force of the tip onto the surface under test is controlled by a small voice coil actuator in a closed control loop. Vertical movements of the stylus are captured by two different, completely independent measurement systems, covering a range of 100 µm. The first one is an interferometer, which provides a traceable signal, and the second one is an inductive measurement system. The signal from the inductive measurement system is calibrated by the interferometer. The sample under test is carried within the x–y-plane by a linear guided table with low noise air bearings. These air bearings are preloaded by vacuum and a constant gap is achieved by gas pressure controllers. Both axes of the table are driven by linear voice coil actuators and their movement in the plane is measured by linear encoders. The sample carrier is equipped with two axes tilt compensation, by which the sample under test can be levelled automatically using the measurement system of the stylus. Real-time data acquisition, manual handling and automated procedures are managed by a programmable controller and proprietary software written in LabVIEW. After measurement, data from the system can be directly transferred into the smd- or sdf-format. Results of measurements on different samples to characterize the metrological behaviour of the instrument will be reported. To characterize the uncertainty of the instrument, a model is applied, which is in accordance with approved rules for contact stylus instruments

  15. Providing radiometric traceability for the calibration home base of DLR by PTB

    Energy Technology Data Exchange (ETDEWEB)

    Taubert, D. R.; Hollandt, J.; Sperfeld, P.; Pape, S.; Hoepe, A.; Hauer, K.-O. [Physikalisch-Technische Bundesanstalt, Braunschweig und Berlin, 10587 Berlin (Germany); Gege, P.; Schwarzmaier, T.; Lenhard, K.; Baumgartner, A. [Deutsches Zentrum fuer Luft- und Raumfahrt, Institut fuer Methodik der Fernerkundung, 82234 Oberpfaffenhofen (Germany)

    2013-05-10

    A dedicated calibration technique was applied for the calibration of the spectral radiance transfer standard (RASTA) of the German Aerospace Center (DLR) at the Physikalisch-Technische Bundesanstalt (PTB), consisting of two independent but complementing calibration procedures to provide redundancy and smallest possible calibration uncertainties. Procedure I included two calibration steps: In a first step the optical radiation source of RASTA, an FEL lamp, was calibrated in terms of its spectral irradiance E{sub {lambda}}({lambda}) in the wavelength range from 350 nm to 2400 nm using the PTB Spectral Irradiance Calibration Equipment (SPICE), while in a second step the spectral radiance factor {beta}{sub 0 Degree-Sign :45 Degree-Sign }({lambda}) of the RASTA reflection standard was calibrated in a 0 Degree-Sign :45 Degree-Sign -viewing geometry in the wavelength range from 350 nm to 1700 nm at the robot-based gonioreflectometer facility of PTB. The achieved relative standard uncertainties (k= 1) range from 0.6 % to 3.2 % and 0.1 % to 0.6 % respectively. Procedure II was completely independent from procedure I and allowed to cover the entire spectral range of RASTA from 350 nm to 2500 nm. In the second procedure, the 0 Degree-Sign :45 Degree-Sign -viewing geometry spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign }({lambda}) of RASTA was directly calibrated at the Spectral Radiance Comparator Facility (SRCF) of PTB. The relative uncertainties for this calibration procedure range from 0.8 % in the visible up to 7.5 % at 2500 nm (k= 1). In the overlapping spectral range of both calibration procedures the calculated spectral radiance L{sub {lambda},0 Degree-Sign :45 Degree-Sign ,calc}({lambda}) from procedure I is in good agreement with the direct measurement of procedure II, i.e. well within the combined expanded uncertainties (k= 2) of both procedures.

  16. Comparison of the air-kerma standards of the PTB and the BIPM in the low-energy X-ray range

    International Nuclear Information System (INIS)

    Burns, D.T.; Bueermann, L.; Kramer, H.M.; Lange, B.

    2001-09-01

    A direct comparison has been made between the air-kerma standards of the Physikalisch-Technische Bundesanstalt (PTB), Germany, and the Bureau International des Poids et Mesures (BIPM) in the x-ray range from 10 kV to 50 kV. Additional measurements were made at 80 kV and 100 kV to provide information on the electron-loss correction for the BIPM standard at these qualities. The comparison took place at the BIPM in March 1999 using the reference conditions recommended by the CCRI. There is general agreement at the level of one standard uncertainty, although there is a significant trend in the results between 30 kV and 50 kVa. This is in part due to the treatment of fluorescence radiation. The effect of fluorescence for the BIPM standard has been calculated using the Monte Carlo code EGSnrc and the fluorescence correction calculated in this way and the effect of including these new values in the present comparison are given. It should be noted, however, that these new correction factors for the BIPM standard have not yet been adopted. The result at 10 kV is significantly different from the others. This is not uncommon and raises a number of possibilities, for example the large corrections for air attenuation and guard wire attenuation, or unexplained aperture effects that have arisen in certain comparisons. In this respect, it is possible that the uncertainties for the 10 kV quality are underestimated. The measurements at 80 kV and 100 kV were made principally to test the correction factors for the BIPM standard, making use of the fact that the large electrode separation of the PTB PK100 chamber results in very little electron loss. (authors)

  17. New blackbody standard for the evaluation and calibration of tympanic ear thermometers at the NPL, United Kingdom

    Science.gov (United States)

    McEvoy, Helen C.; Simpson, Robert; Machin, Graham

    2004-04-01

    The use of infrared tympanic thermometers for monitoring patient health is widespread. However, studies into the performance of these thermometers have questioned their accuracy and repeatability. To give users confidence in these devices, and to provide credibility in the measurements, it is necessary for them to be tested using an accredited, standard blackbody source, with a calibration traceable to the International Temperature Scale of 1990 (ITS-90). To address this need the National Physical Laboratory (NPL), UK, has recently set up a primary ear thermometer calibration (PET-C) source for the evaluation and calibration of tympanic (ear) thermometers over the range from 15 °C to 45 °C. The overall uncertainty of the PET-C source is estimated to be +/- 0.04 °C at k = 2. The PET-C source meets the requirements of the European Standard EN 12470-5: 2003 Clinical thermometers. It consists of a high emissivity blackbody cavity immersed in a bath of stirred liquid. The temperature of the blackbody is determined using an ITS-90 calibrated platinum resistance thermometer inserted close to the rear of the cavity. The temperature stability and uniformity of the PET-C source was evaluated and its performance validated. This paper provides a description of the PET-C along with the results of the validation measurements. To further confirm the performance of the PET-C source it was compared to the standard ear thermometer calibration sources of the National Metrology Institute of Japan (NMIJ), Japan and the Physikalisch-Technische Bundesanstalt (PTB), Germany. The results of this comparison will also be briefly discussed. The PET-C source extends the capability for testing ear thermometers offered by the NPL body temperature fixed-point source, described previously. An update on the progress with the commercialisation of the fixed-point source will be given.

  18. Cryogenic radiometry in the hard X-ray range

    International Nuclear Information System (INIS)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Muller, P.; Rabus, H.; Ulm, G.

    2008-01-01

    For many applications in radiometry, spectroscopy or astrophysics, absolute measurement of radiant power with low uncertainty is essential. Cryogenic electrical substitution radiometers (ESRs) are regarded as the highest-accuracy primary standard detector in radiometry, from the infrared to the ultraviolet region; in combination with tuneable monochromatized synchrotron radiation from electron storage rings, their range of operation has been extended to the soft x-ray region. ESRs are absolute thermal detectors, based on the equivalence of electrical power and radiant power that can be traced back to electrical SI units and be measured with low uncertainties. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time suitable for use with synchrotron radiation. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard x-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV, resulting in a cavity absorber with a gold base and a cylindrical shell made of copper, in combination with a thermal sensitivity of around 150 mK μW -1 and a time constant of less than 3 min, which is short compared with the lifetime of many hours for the storage ring current. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2%, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3%. (authors)

  19. Cryogenic radiometry in the hard X-ray range

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Muller, P.; Rabus, H.; Ulm, G. [Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Berlin (Germany)

    2008-10-15

    For many applications in radiometry, spectroscopy or astrophysics, absolute measurement of radiant power with low uncertainty is essential. Cryogenic electrical substitution radiometers (ESRs) are regarded as the highest-accuracy primary standard detector in radiometry, from the infrared to the ultraviolet region; in combination with tuneable monochromatized synchrotron radiation from electron storage rings, their range of operation has been extended to the soft x-ray region. ESRs are absolute thermal detectors, based on the equivalence of electrical power and radiant power that can be traced back to electrical SI units and be measured with low uncertainties. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time suitable for use with synchrotron radiation. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard x-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV, resulting in a cavity absorber with a gold base and a cylindrical shell made of copper, in combination with a thermal sensitivity of around 150 mK {mu}W{sup -1} and a time constant of less than 3 min, which is short compared with the lifetime of many hours for the storage ring current. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2%, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3%. (authors)

  20. Cryogenic radiometry in the hard x-ray range

    Science.gov (United States)

    Gerlach, M.; Krumrey, M.; Cibik, L.; Müller, P.; Rabus, H.; Ulm, G.

    2008-10-01

    For many applications in radiometry, spectroscopy or astrophysics, absolute measurement of radiant power with low uncertainty is essential. Cryogenic electrical substitution radiometers (ESRs) are regarded as the highest-accuracy primary standard detector in radiometry, from the infrared to the ultraviolet region; in combination with tuneable monochromatized synchrotron radiation from electron storage rings, their range of operation has been extended to the soft x-ray region. ESRs are absolute thermal detectors, based on the equivalence of electrical power and radiant power that can be traced back to electrical SI units and be measured with low uncertainties. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time suitable for use with synchrotron radiation. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard x-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV, resulting in a cavity absorber with a gold base and a cylindrical shell made of copper, in combination with a thermal sensitivity of around 150 mK µW-1 and a time constant of less than 3 min, which is short compared with the lifetime of many hours for the storage ring current. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2%, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity was used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3%.

  1. 5th international exhaust gas and particulate emissions forum. Proceedings; 5. Internationales Forum Abgas- und Partikelemissionen. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-12-11

    The Proceedings of the 5th International Exhaust Gas and Particulate Emissions Forum contains 22 printed contributions as well as a CD-ROM. The titles of them are: (1) Diesel Emissions Control in the United States - 2010 and Beyond; (2) The MBE90 commercial vehicle engine for EPA '07 emissions regulations; (3) Concepts for engines and exhaust-gas cleaning systems for heavy duty trucks of the future; (4) HD Engine Technology for Near-Zero Emissions and Lowest Cost of Ownership; (5) (Partially-) Homogeneous Diesel Combustion; (6) Exhaust gas sensors for NOx storage catalysts and ammonia-SCR systems; (7) Sensors for modern exhaust gas after-treatment systems; (8) New reducing agents for low NOx-SCR Techno-logy; (9) Exhaust gas Aftertreatment on Lean Burn Gasoline Direct Injection Engines: The System of TWC and NOx-Storage Catalyst; (10) New Platinum/Palladium based catalyzed filter technologies for future passenger car applications; (11) Development of a Roadway Hydrocarbon Sorption Model and Characterization of a Novel PM Generator; (12) Requirements for current and future particulate measurement instrumentation from the point of view of the Physikalisch-Technische Bundesanstalt; (13) Standardized dilution conditions for gravimetric PM sampling - measures to assure results that correlate; (14) Particle Counting according PMP; (15) Future high-confidence measurement of diesel particulate emissions for approval and development; (16) New developments in optical instrumentation for exhaust gas; (17) Simultaneous Detection of Gaseous and Particulate Exhaust Components by Photoacoustic Spectroscopy; (18) Boundaries of modern exhaust gas instrumentation; (19) Raising quality and reducing application effort through efficient data input to the particulate filter load model for a EURO5 diesel car; (20) Stop-start operation of diesel engines - modified require-ment for exhaust gas after-treatment?; (21) Particulates emission with Biodiesel B30 impact on CSF management; (22

  2. 'BioQuaRT' project: design of a novel in situ protocol for the simultaneous visualisation of chromosomal aberrations and micronuclei after irradiation at microbeam facilities

    International Nuclear Information System (INIS)

    Patrono, C.; Testa, A.; Monteiro Gil, O.; Giesen, U.; Langner, F.; Rabus, H.; Pinto, M.

    2015-01-01

    The aim of the 'BioQuaRT' (Biologically weighted Quantities in Radiotherapy) project is to develop measurement techniques for characterising charged particle track structure on different length scales, and to correlate at the cellular level the track structure properties with the biological effects of radiation. This multi-scale approach will allow characterisation of the radiation qualities used in radiotherapy and the related biological effects. Charged-particle microbeam facilities were chosen as the platforms for all radiobiology experiments in the 'BioQuaRT' project, because they allow targeting single cells (or compartments of a cell) with a predefined number of ionising particles and correlating the cell-by-cell induced damage with type and energy of the radiation and with the number of ions per cell. Within this project, a novel in situ protocol was developed for the analysis of the mis-repaired and/or unrepaired chromosome damage induced by charged-particle irradiations at the Physikalisch-Technische Bundesanstalt (PTB) ion microbeam facility. Among the cytogenetic biomarkers to detect and estimate radiation-induced DNA damage in radiobiology, chromosomal aberrations and micronuclei were chosen. The characteristics of the PTB irradiation system required the design of a special in situ assay: specific irradiation dishes with a base made from a bio-foil 25-μm thick and only 3000-4000 cells seeded and irradiated per dish. This method was developed on Chinese hamster ovary (CHO) cells, one of the most commonly used cell lines in radiobiology in vitro experiments. The present protocol allows the simultaneous scoring of chromosome aberrations and micronuclei on the same irradiated dish. Thanks to its versatility, this method could also be extended to other radiobiological applications besides the single-ion microbeam irradiations. (authors)

  3. Feasibility study of entrance and exit dose measurements at the contra lateral breast with alanine/electron spin resonance dosimetry in volumetric modulated radiotherapy of breast cancer

    Science.gov (United States)

    Wagner, Daniela M.; Hüttenrauch, Petra; Anton, Mathias; von Voigts-Rhetz, Philip; Zink, Klemens; Wolff, Hendrik A.

    2017-07-01

    The Physikalisch-Technische Bundesanstalt has established a secondary standard measurement system for the dose to water, D W, based on alanine/ESR (Anton et al 2013 Phys. Med. Biol. 58 3259-82). The aim of this study was to test the established measurement system for the out-of-field measurements of inpatients with breast cancer. A set of five alanine pellets were affixed to the skin of each patient at the contra lateral breast beginning at the sternum and extending over the mammilla to the distal surface. During 28 fractions with 2.2 Gy per fraction, the accumulated dose was measured in four patients. A cone beam computer tomography (CBCT) scan was generated for setup purposes before every treatment. The reference CT dataset was registered rigidly and deformably to the CBCT dataset for 28 fractions. To take the actual alanine pellet position into account, the dose distribution was calculated for every fraction using the Acuros XB algorithm. The results of the ESR measurements were compared to the calculated doses. The maximum dose measured at the sternum was 19.9 Gy  ±  0.4 Gy, decreasing to 6.8 Gy  ±  0.2 Gy at the mammilla and 4.5 Gy  ±  0.1 Gy at the distal surface of the contra lateral breast. The absolute differences between the calculated and measured doses ranged from  -1.9 Gy to 0.9 Gy. No systematic error could be seen. It was possible to achieve a combined standard uncertainty of 1.63% for D W  =  5 Gy for the measured dose. The alanine/ESR method is feasible for in vivo measurements.

  4. Determination of cross sections for the production of low-energy monoenergetic neutron fields; Determination de sections efficaces pour la production de champs neutroniques monoenergetiques de basse energie

    Energy Technology Data Exchange (ETDEWEB)

    Lamirand, Vincent

    2011-11-18

    The response of a neutron detector, defined as the reading of the device per unit of incident fluence or dose, varies with neutron energy. The experimental determination of this variation, i.e. of the response function of this instrument, has to be performed by facilities producing monoenergetic neutron fields. These neutrons are commonly produced by interaction between accelerated ions (proton or deuteron) onto a thin target composed of a reactive layer deposited on a metallic backing. Using the {sup 7}Li(p, n), {sup 3}H(p, n), {sup 2}H(d, n) and {sup 3}H(d, n) reactions, monoenergetic neutrons are obtained between 120 keV and 20 MeV in the ion beam direction (0 deg.). To reach lower neutron energies, the angle of the measuring point with respect to the ion beam direction can be increased. However, this method presents several problems of neutron energy and fluence homogeneities over the detector surface, as well as an important increase of the scattered neutron contribution. Another solution is to investigate other nuclear reactions, as {sup 45}Sc(p, n) allowing to extend the neutron energy range down to 8 keV at 0 deg.. A complete study of this reaction and its cross section has been undertaken within the framework of a scientific cooperation between the laboratory of neutron metrology and dosimetry (IRSN, France), two European national metrological institutes, the National Physical Laboratory (UK) and the Physikalisch-Technische Bundesanstalt (Germany), and IRMM, the Institute for Reference Materials and Measurements (EC). In parallel, other possible reactions have been investigated: {sup 65}Cu(p, n), {sup 51}V(p, n), {sup 57}Fe(p, n), {sup 49}Ti(p, n), {sup 53}Cr(p, n) and {sup 37}Cl(p, n). They were compared in terms of neutron fluence and minimum energy of the produced neutrons. (author)

  5. Utilization of coincidence criteria in absolute length measurements by optical interferometry in vacuum and air

    International Nuclear Information System (INIS)

    Schödel, R

    2015-01-01

    Traceability of length measurements to the international system of units (SI) can be realized by using optical interferometry making use of well-known frequencies of monochromatic light sources mentioned in the Mise en Pratique for the realization of the metre. At some national metrology institutes, such as Physikalisch-Technische Bundesanstalt (PTB) in Germany, the absolute length of prismatic bodies (e.g. gauge blocks) is realized by so-called gauge-block interference comparators. At PTB, a number of such imaging phase-stepping interference comparators exist, including specialized vacuum interference comparators, each equipped with three highly stabilized laser light sources. The length of a material measure is expressed as a multiple of each wavelength. The large number of integer interference orders can be extracted by the method of exact fractions in which the coincidence of the lengths resulting from the different wavelengths is utilized as a criterion. The unambiguous extraction of the integer interference orders is an essential prerequisite for correct length measurements. This paper critically discusses coincidence criteria and their validity for three modes of absolute length measurements: 1) measurements under vacuum in which the wavelengths can be identified with the vacuum wavelengths, 2) measurements under air in which the air refractive index is obtained from environmental parameters using an empirical equation, and 3) measurements under air in which the air refractive index is obtained interferometrically by utilizing a vacuum cell placed along the measurement pathway. For case 3), which corresponds to PTB’s Kösters-Comparator for long gauge blocks, the unambiguous determination of integer interference orders related to the air refractive index could be improved by about a factor of ten when an ‘overall dispersion value,’ suggested in this paper, is used as coincidence criterion. (paper)

  6. TIMED solar EUV experiment: preflight calibration results for the XUV photometer system

    Science.gov (United States)

    Woods, Thomas N.; Rodgers, Erica M.; Bailey, Scott M.; Eparvier, Francis G.; Ucker, Gregory J.

    1999-10-01

    The Solar EUV Experiment (SEE) on the NASA Thermosphere, Ionosphere, and Mesosphere Energetics and Dynamics (TIMED) mission will measure the solar vacuum ultraviolet (VUV) spectral irradiance from 0.1 to 200 nm. To cover this wide spectral range two different types of instruments are used: a grating spectrograph for spectra between 25 and 200 nm with a spectral resolution of 0.4 nm and a set of silicon soft x-ray (XUV) photodiodes with thin film filters as broadband photometers between 0.1 and 35 nm with individual bandpasses of about 5 nm. The grating spectrograph is called the EUV Grating Spectrograph (EGS), and it consists of a normal- incidence, concave diffraction grating used in a Rowland spectrograph configuration with a 64 X 1024 array CODACON detector. The primary calibrations for the EGS are done using the National Institute for Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF-III) in Gaithersburg, Maryland. In addition, detector sensitivity and image quality, the grating scattered light, the grating higher order contributions, and the sun sensor field of view are characterized in the LASP calibration laboratory. The XUV photodiodes are called the XUV Photometer System (XPS), and the XPS includes 12 photodiodes with thin film filters deposited directly on the silicon photodiodes' top surface. The sensitivities of the XUV photodiodes are calibrated at both the NIST SURF-III and the Physikalisch-Technische Bundesanstalt (PTB) electron storage ring called BESSY. The other XPS calibrations, namely the electronics linearity and field of view maps, are performed in the LASP calibration laboratory. The XPS and solar sensor pre-flight calibration results are primarily discussed as the EGS calibrations at SURF-III have not yet been performed.

  7. 5th international exhaust gas and particulate emissions forum. Proceedings; 5. Internationales Forum Abgas- und Partikelemissionen. Beitraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-12-11

    The Proceedings of the 5th International Exhaust Gas and Particulate Emissions Forum contains 22 printed contributions as well as a CD-ROM. The titles of them are: (1) Diesel Emissions Control in the United States - 2010 and Beyond; (2) The MBE90 commercial vehicle engine for EPA '07 emissions regulations; (3) Concepts for engines and exhaust-gas cleaning systems for heavy duty trucks of the future; (4) HD Engine Technology for Near-Zero Emissions and Lowest Cost of Ownership; (5) (Partially-) Homogeneous Diesel Combustion; (6) Exhaust gas sensors for NOx storage catalysts and ammonia-SCR systems; (7) Sensors for modern exhaust gas after-treatment systems; (8) New reducing agents for low NOx-SCR Techno-logy; (9) Exhaust gas Aftertreatment on Lean Burn Gasoline Direct Injection Engines: The System of TWC and NOx-Storage Catalyst; (10) New Platinum/Palladium based catalyzed filter technologies for future passenger car applications; (11) Development of a Roadway Hydrocarbon Sorption Model and Characterization of a Novel PM Generator; (12) Requirements for current and future particulate measurement instrumentation from the point of view of the Physikalisch-Technische Bundesanstalt; (13) Standardized dilution conditions for gravimetric PM sampling - measures to assure results that correlate; (14) Particle Counting according PMP; (15) Future high-confidence measurement of diesel particulate emissions for approval and development; (16) New developments in optical instrumentation for exhaust gas; (17) Simultaneous Detection of Gaseous and Particulate Exhaust Components by Photoacoustic Spectroscopy; (18) Boundaries of modern exhaust gas instrumentation; (19) Raising quality and reducing application effort through efficient data input to the particulate filter load model for a EURO5 diesel car; (20) Stop-start operation of diesel engines - modified require-ment for exhaust gas after-treatment?; (21) Particulates emission with Biodiesel B30 impact on CSF management; (22

  8. Comparison between Electronic Portal Imaging Devices and ion chamber matrix for intensity-modulated radiotherapy quality assurance; Comparacao entre Dispositivos Eletronicos de Imagens Portais e matriz de camaras de ionizacao para garantia da qualidade de radioterapia de intensidade modulada

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, Thiago B.; Rosa, Luiz A.R., E-mail: thiago.fisimed@gmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Lima, Marilia B., E-mail: thiago.fisimed@gmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil). Departamento de Fisica Medica

    2012-08-15

    The treatment with intensity-modulated radiotherapy (IMRT) demands an individual and specific quality assurance procedure. The use of ion chamber matrix is a well establish method to dose distribution verifications, despite the lower spatial resolution. An alternative method arising is the use of the Electronic Portal Imaging Devices (EPIDs). The aim of this paper is to validate the EPID use for quality assurance of IMRT comparing it to the previous method employing an ion chamber matrix. We analyzed 10 treatment planning for different tumor sites and photons energies of the linac Trilogy (Varian Medical Systems). We used Sliding-window IMRT and the measurements were acquired in EPID and in Physikalisch-Technische Werkstaetten (PTW) 2D Array seven29. Two different software were used to analyze the data: Verisoft version 4.0, for Array data; and Eclipse 8.6 with Portal Dosimetry for EPID data. The evaluation of concordance levels between measured and predicted images used the Gamma Index tool with 3% of dose difference and 3 mm of distance to agreement. The EPID showed worse results for approval percentiles, in average 2.17%, and bigger values of average gamma index, although its analysis confirmed the approvals of all planning. This happens because of the better sensitivity generated by the higher spatial resolution of the EPID, 0,784 mm against 1,0 cm of the Array, so it has bigger capacity to identify small dose variations. The EPID, jointly with the Portal Dosimetry, proved to be excellent tools to perform pre-treatment IMRT verifications, providing significant gain in dose distribution analysis. Also, the EPID is easier for positioning, for images manipulation, for data acquisition and analysis and has detection area 60% bigger. (author)

  9. Experimental determination of kQ factors for cylindrical ionization chambers in 10 cm × 10 cm and 3 cm × 3 cm photon beams from 4 MV to 25 MV.

    Science.gov (United States)

    Krauss, A; Kapsch, R P

    2014-08-07

    For the ionometric determination of absorbed dose to water, Dw, in megavoltage photon beams from a linear accelerator, beam-quality-dependent correction factors, kQ, are used for the ionization chambers. By using a water calorimeter, these factors can be determined experimentally and with substantially lower standard uncertainties compared to calculated values of the kQ, which are published in various dosimetry protocols. In this investigation, kQ for different types of cylindrical ionization chambers (NE 2561, NE 2571, FC 65 G) were determined experimentally in 10 cm × 10 cm photon beams from 4 MV to 25 MV (corresponding beam quality index TPR20,10 from 0.64 to 0.80). The measurements were carried out at the linear accelerator facility of the Physikalisch-Technische Bundesanstalt. It is shown that the kQ factors for a single ionization chamber in 10 cm × 10 cm photon beams can be measured with a relative standard uncertainty of 0.31%. In addition to these measurements in 10 cm × 10 cm fields, kQ factors for the NE 2561 chamber were also determined in smaller 3 cm × 3 cm photon beams between 6 MV and 25 MV. In this case, relative standard uncertainties between 0.35 % and 0.38 % are achieved for the kQ factors. It is found for this ionization chamber, that the ratio of the kQ factors in 3 cm × 3 cm and in 10 cm × 10 cm beams increases with increasing TPR20,10 to reach a value of 1.0095 at TPR20,10 = 0.8 with a relative standard uncertainty of 0.4 %.

  10. Solarthermie 2000. Sub-programme 2: Solar thermal demonstration projects in public buildings in East Germany - Scientific and technical studies accompanying construction and operation of solar thermal demonstration plants in the states of south western Germany. Final report; Solarthermie 2000. Teilprogramm 2: Solarthermische Demonstrationsanlagen fuer oeffentliche Gebaeude mit Schwerpunkt in den neuen Bundeslaendern - Wissenschaftlich-technische Begleitung der solarthermischen Demonstrationsanlagen in den suedwestlichen Bundeslaendern. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bollin, E.; Himmelsbach, S.; Klingenberger, U.M.

    2002-06-01

    Exemplary solar thermal power systems with a minimum collector surfaces of 100 square metres are presented, improved and optimized. Their competitive strength is to be improved by reducing the specific system cost and raising the specific useful power generation. [German] Im Programm 'Solarthermie-2000' Teilprogramm 2 soll anhand von Beispielloesungen fuer groessere solarthermische Anlagen mit einer Mindestkollektorflaeche von 100 m{sup 2} an unterschiedlich genutzten Gebaeuden nachgewiesen werden, dass im Bereich der thermischen Solarenergienutzung technisch gute Loesungen zur Verfuegung gestellt werden koennen. Diese Systemloesungen sollen weiter verbessert und angepasst werden. Zugleich soll erreicht werden, dass die wirtschaftliche Konkurrenzfaehigkeit gesteigert wird, indem durch Reduzierung der spezifischen Systemkosten und Erhoehung des spezifischen Nutzenergieertrages die solaren Nutzwaermekosten gesenkt werden. (orig.)

  11. Risicoleerlingen bij technisch lezen

    NARCIS (Netherlands)

    Houtveen, A.A.M.; Mijs, T.J.E.; Vernooy, C.G.T.; Grift, W.J.C. van der; Koekebacker, E.

    2003-01-01

    Dit project laat zien, dat verbetering van leesprestaties haalbaar is. Men zou de vraag kunnen stellen of die verbetering stand houdt, ook als de begeleiding ophoudt. Om daar zicht op te krijgen is evaluatieonderzoek noodzakelijk. Vaak worden er door de overheid geen financiën beschikbaar gesteld

  12. Stenting und technische Stentumgebung

    Science.gov (United States)

    Hoffstetter, Marc; Pfeifer, Stefan; Schratzenstaller, Thomas; Wintermantel, Erich

    In hoch entwickelten Industrieländern stehen laut Weltgesundheitsorganisation (WHO) Herz-Kreislauf-Erkrankungen und speziell die Koronare Herzkrankheit (KHK) an erster Stelle der Todesursachen. In Deutschland betrug die Zahl der erfassten, an KHK erkrankten Personen ohne Berücksichtigung der Dunkelziffer allein im Jahre 2001 über 473.000. Die KHK war im Jahre 2003 mit 92.673 erfassten Todesfällen immer noch die häufigste Todesursache, obgleich in Deutschland die Häufigkeit der Koronarinterventionen zur Behandlung der KHK zwischen 1984 und 2003 um fast das 80fache von 2.809 auf 221.867 Eingriffe pro Jahr gestiegen ist [1]. Neben der hohen Zahl an Todesfällen haben die betroffenen Personen durch chronische Schmerzen und eingeschränkte körperliche Leistungsfähigkeit zusätzlich eine starke Beeinträchtigung der Lebensqualität [2].In Folge dessen wird die erkrankte Person häufig zum Pflegefall was neben den gesundheitlichen Aspekten auch eine sozioökonomische Komponente in Form der fehlenden Arbeitskraft und den auftretenden Pflegekosten nach sich zieht. Die Kosten für die Behandlung der KHK in Deutschland beliefen sich im Jahre 2002 laut Statistischem Bundesamt auf rund 6,9 Mrd. €. Verglichen mit ähnlichen Zahlen der USA dürfte sich der entstandene Schaden für die deutsche Volkswirtschaft im zwei- bis dreistelligen Milliardenbereich bewegen [3].

  13. Technical and economical optimization of wood gasification in a circulating fluidized bed. Final report; Technische und wirtschaftliche Optimierung der Vergasung von Holz in der zirkulierenden Wirbelschicht. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Ising, M.; Unger, C.; Heunemann, F.; Dinkelbach, L.

    2002-12-01

    Prozessautomatisierung und das Verbesserungspotenzial hinsichtlich Abgasemissionen am Motor. Darueber hinaus wurde eine detaillierte vergleichende betriebswirtschaftliche Bewertung des Verfahrens vorgenommen. Dabei stellte sich das neue technische Verfahren positiver als etablierte Techniken dar. (orig.)

  14. Progress in physical chemistry

    CERN Document Server

    Hempelmann, Rolf

    2008-01-01

    Progress in Physical Chemistry is a collection of recent ""Review Articles"" published in the ""Zeitschrift für Physikalische Chemie"". The second volume of Progress in Physical Chemistry is a collection of thematically closely related minireview articles written by the members of the Collaborative Research Centre (SFB) 277 of the German Research Foundation (DFG). These articles are based on twelve years of intense coordinated research efforts. Central topics are the synthesis and the characterization of interface-dominated, i.e. nanostructured materials, mainly in the solid state but also as

  15. HACCP, food quality, food irradiation; HACCP, Lebensmittelqualitaet und Bestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Bognar, A [Bundesforschungsanstalt fuer Ernaehrung, Karlsruhe (Germany). Inst. fuer Chemie und Biologie

    1999-07-01

    The paper summarizes the principles and purposes of the ''Hazard Analysis Critical Control Points'' (HACCP) system and its application and implementation within the European Union for the purposes of food quality and safety control, including food irradiation. (orig./CB) [German] Eine ausfuehrliche Information und Schulung der mit der Qualitaetssicherung befassten Mitarbeiter ueber den Inhalt und die Ziele des HACCP-Konzeptes erscheint als die wichtigste Voraussetzung fuer seine Implementierung in das Qualitaetsmanagement bei der Lebensmittelverarbeitung. Abschliessend soll noch auf die Gefahren hingewiesen werden, die bei der Einfuehrung eines neuen Qualitaetssicherungssystems in Lebensmittelbetrieben auftreten koennen. Die groesste Gefahr scheint die Ueberorganisation des betrieblichen Ablaufs zu sein. Papierberge, die niemand liest oder beachtet, sind kontra produktiv. (orig.)

  16. HACCP, food quality, food irradiation; HACCP, Lebensmittelqualitaet und Bestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Bognar, A. [Bundesforschungsanstalt fuer Ernaehrung, Karlsruhe (Germany). Inst. fuer Chemie und Biologie

    1999-07-01

    The paper summarizes the principles and purposes of the ''Hazard Analysis Critical Control Points'' (HACCP) system and its application and implementation within the European Union for the purposes of food quality and safety control, including food irradiation. (orig./CB) [German] Eine ausfuehrliche Information und Schulung der mit der Qualitaetssicherung befassten Mitarbeiter ueber den Inhalt und die Ziele des HACCP-Konzeptes erscheint als die wichtigste Voraussetzung fuer seine Implementierung in das Qualitaetsmanagement bei der Lebensmittelverarbeitung. Abschliessend soll noch auf die Gefahren hingewiesen werden, die bei der Einfuehrung eines neuen Qualitaetssicherungssystems in Lebensmittelbetrieben auftreten koennen. Die groesste Gefahr scheint die Ueberorganisation des betrieblichen Ablaufs zu sein. Papierberge, die niemand liest oder beachtet, sind kontra produktiv. (orig.)

  17. Stochastic Control Theory, Nonlinear Structural Mechanics and Applied Combinatorics

    Science.gov (United States)

    1989-05-12

    More specifically: (") x 3 PAS and Steiner triple systems; (") x 4 PAS and Steiner triple systems which can be nested; and (’) x 5 PAS and Steiner ...am Rudolf Wille CONCEPTUAL SCALING Technische Hochschule Darmstadt Abstract: Scaling of empirical data uses formal patterns to lead to a better...of Arizona Jan 18 - 22 Wille, Rudolf Technische Hochschule Darmstadt Jan 17 - 23 21 APPLICATIONS OF COMBINATORICS AND GRAPH THEORY TO THE BIOLOGICAL

  18. Quality assurance when surface welding nickel-based alloys; Qualitaetssicherung bei der Auftragsschweissung von Nickelbasislackierungen

    Energy Technology Data Exchange (ETDEWEB)

    Metschke, J. [Muellkraftwerk Schwandorf Betriebsgesellschaft mbH (Germany)

    2003-07-01

    The cladding of evaporator heat exchanger surfaces in refuse incineration boilers with alloy 625 can effectively protect against the corrosive wear of the basic tube if the described rules concerning the pre-treatment, processing, quality control and after-care are observed. This statement is supported by the positive experience with this alloy at the Schwandorf refuse-fired power plant over a period of eight years now. Since the maximum service temperature is limited to 420 C, alloy 625 is only suitable for protecting superheater pipes subject to certain conditions. Long-term experience with alternative nickel-based alloys (alloy 622, alloy 686 and others) are not yet available. (orig.) [German] Die Schweissplattierung von Verdampferwaermetauscherflaechen in Muellverbrennungskesseln mit Alloy 625 kann einen wirksamen Schutz gegen den korrosiven Verschleiss des Grundrohres darstellen, wenn die vorstehenden Regeln ueber Vorbehandlung, Verarbeitung, Qualitaetskontrolle und laufende Nachsorgearbeiten beachtet werden. Diese Aussage wird durch die positiven Erfahrungen mit dieser Legierung im Muellkraftwerk Schwandorf ueber einen Zeitraum von nunmehr acht Jahren gestuetzt. (orig.)

  19. Combining the Observations from Different GNSS (Invited)

    Science.gov (United States)

    Dach, R.; Lutz, S.; Schaer, S.; Bock, H.; Jäggi, A.; Meindl, M.; Ostini, L.; Thaller, D.; Steinbach, A.; Beutler, G.; Steigenberger, P.

    2009-12-01

    For a very long time GPS has clearly dominated the use of GNSS measurements for scientific purposes. This picture is changing: we are moving from a GPS-only to a multi-GNSS world. This is, e.g., reflected by changing the meaning of the abbreviation IGS in March 2005 from International GPS to GNSS Service. The current situation can be described as follows: GPS has the leading role in the GNSS because it has provided a very stable satellite constellation over many years. Some of the currently active GPS satellites are nearly 15 years old. These old satellites are expected to be decommissioned within the next years. On the other hand, due to the increasing number of active GLONASS satellites and the improved density of multi-GNSS tracking stations in the IGS network, the quality of the GLONASS orbits has drastically improved during the last years. The European Galileo system is under development: currently two test satellites (GIOVE-A and GIOVE-B) are in orbit. The IOV (in-orbit-validation phase) will start soon. Also the first test satellites for the Chinese Compass system are in space. For the maximum benefit the observations of these GNSS will be processed in a combined multi-GNSS analysis in future. CODE (Center for Orbit Determination in Europe) is a joint venture between the Astronomical Institute of the University Bern (AIUB, Bern, Switzerland), the Federal Office of Topography (swisstopo, Wabern, Switzerland), the Federal Agency for Cartography and Geodesy (BKG, Frankfurt am Main, Germany), and the Institut für Astronomische und Physikalische Geodäsie of the Technische Universität München (IAPG/TUM, Munich, Germany). It acts as one of the global analysis centers of the IGS and has started in May 2003 with a rigorous combined processing of GPS and GLONASS measurements for the final, rapid, and even ultra-rapid product lines. All contributions from CODE to the IGS are in fact multi-GNSS products -- the only exception is the satellite and receiver clock

  20. Ideengeschichte der Physik

    CERN Document Server

    Kuhn, Wildfried

    2016-01-01

    Die Ideengeschichte der Physik geht neue Wege, indem sie den umfangreichen historischen Stoff nicht additiv darstellt, sondern wissenschaftstheoretisch reflektiert und nach thematischen Leitlinien (Materievorstellungen, Raum und Zeit, Erhaltungskonzepte, Extremalprinzipien, Theorie und Experiment) strukturiert. Damit vermittelt diese Darstellung im historischen Kontext ein tieferes Verständnis des physikalischen Denkens von der Antike bis heute und lotet zugleich die Dimension der Genesis physikalischer Begriffe aus, die in modernen Lehrbüchern zumeist nicht dargelegt wird. Das Credo Kuhns: Wer über die handwerkliche Handhabung von Physik hinausgehen will, muss sich zwingend mit der Frage befassen, was physikalisches Denken ausmacht und wie es entstanden ist. Die vorliegende zweite Auflage wurde ergänzt durch ein Vorwort von Prof. Dr. Oliver Schwarz, der im Institut Wilfried Kuhns forschen konnte und dabei dessen Denk- und Arbeitsweisen kennengelernt hat.

  1. Technical description of the test section SUCOT to investigate a water/steam two-phase flow; Technische Beschreibung der Testanlage SUCOT zur Untersuchung Wasser/Wasserdampf Zweiphasenstroemung

    Energy Technology Data Exchange (ETDEWEB)

    Daubner, M.; Janssens-Maenhout, G.; Knebel, J.U.

    2002-02-01

    Within the POOLTHY Project of the European Union (Euratom Fourth Framework Programme contract FJ4J-CT95-0003) an active/passive concept (SUCO-Programme) was investigated which controls the heat removal after a potential core melt-down accident in an evolutionary light water reactor by spreading and stabilising the core melt in the reactor sump and flooding the melt with sump water from above. The experiments were performed in the test facility SUCOT which was designed and erected at the Institute for Nuclear and Energy Technologies (IKET). The report gives an overview on the SUCO-Programme and the scaling analysis, which was applied to design the test facility SUCOT. A detailed technical description of the test facility SUCOT is given, in which the natural circulation driven two-phase flow within the reactor sump and relevant phenomena such as flow boiling, disperse bubbly flow with and without mass transfer, and geysering are investigated. The major components of the test facility, the three-loop system and the instrumentation are described. Finally, a perspective for future application of the gained knowledge is given. (orig.) [German] Im Rahmen des POOLTHY Projekts der Europaeischen Union (Euratom Fourth Framework Programme Kennzeichen FJ4J-CT95-0003) wurde ein aktiv/passives Konzept (SUCO-Programm) zur Beherrschung der Nachwaermeabfuhr nach einem potenziellen Kernschmelzunfall in einem evolutionaeren Leichtwasserreaktor untersucht. Das Konzept sieht eine stabile Ausbreitung der Kernschmelze im Reaktorsumpf und deren Kuehlung von oben mit Sumpfwasser vor. Die experimentellen Arbeiten wurden in der dafuer entwickelten und am Institut fuer Kern- und Energietechnik (IKET) gebauten Testanlage SUCOT durchgefuehrt. Der Bericht gibt einen Ueberblick ueber das SUCO-Programm und die Aehnlichkeitsskalierung, die zur Auslegung der Testanlage SUCOT verwendet wurde. Es wird eine detaillierte technische Beschreibung der Testanlage SUCOT gegeben, die zur Untersuchung der durch

  2. Gedifferentieerde Risicobeoordeling Technisch-wetenschappelijke mogelijkheden

    NARCIS (Netherlands)

    Linders JBHJ; Brouwer WWM; CSR

    1999-01-01

    This document contains an overview of the technical and scientific possibilities for performing a tailored assessment of the environmental risks in the registration of pesticides in the Netherlands. Various components of this environmental assessment were analyzed to show to what extent, for

  3. Thermodynamik grundlagen und technische anwendungen

    CERN Document Server

    Baehr, Hans Dieter

    2009-01-01

    Für die aktualisierte 14. Auflage des bewährten Lehrbuchs der Technischen Thermodynamik wurde das Kapitel über Wärmekraftanlagen gründlich bearbeitet und durch einen Abschnitt zur Energiewandlung ergänzt: Die Energiebedarfsstruktur von Deutschland wird erläutert, und die möglichen Energiewandlungspfade werden diskutiert. Schwerpunkt des Buches ist die ausführliche und auch dem Anfänger verständliche Darstellung der Grundlagen der Thermodynamik mit der sorgfältigen Einführung der thermodynamischen Begriffe und den fundamentalen Bilanzgleichungen für Energie, Entropie und Exergie. Die thermodynamischen Eigenschaften reiner Fluide und fluider Gemische werden eingehend erläutert. Darauf aufbauend wird die Thermodynamik der Gemische und der chemischen Reaktionen entwickelt. Auch die thermodynamischen Aspekte wichtiger energie- und verfahrenstechnischer Anwendungen werden praxisnah behandelt: - Strömungs- und Arbeitsprozesse, - thermische Stofftrennverfahren, - Verbrennungsprozesse und Verbrennungsk...

  4. Waste management in underground mining. Colloquium; Abfallentsorgung im Bergbau unter Tage. Tagung

    Energy Technology Data Exchange (ETDEWEB)

    Frenz, W.; Martens, P.N.; Pretz, T. (eds.)

    2001-07-01

    The problem of underground waste management is reviewed from various aspects. Technical, legal and ecological problems are outlined with particular emphasis on the aspect of long-term safety. [German] Ziel unserer Veranstaltung ist, die Problematik der untertaegigen Abfallentsorgung aus den unterschiedlichsten Perspektiven zu beleuchten. Sowohl die technische als auch die rechtliche wie auch die oekologische Sichtweise werden aufgezeigt. In technischer Hinsicht werden der aktuelle Stand der Methoden und Fortentwicklungsmoeglichkeiten dargestellt und anhand konkreter Beispiele erlaeutert. Besondere Bedeutung hat dabei die Frage der Langzeitsicherheit. (orig.)

  5. Mass generation via the Higgs boson and the quark condensate of ...

    Indian Academy of Sciences (India)

    2016-08-24

    Aug 24, 2016 ... Physikalisches Institut der Universität Göttingen, Friedrich-Hund-Platz 1, D-37077 Göttingen, Germany .... above, this paper contains a history of the subject from ... In figure 1 the symmetry breaking process is illustrated.

  6. Self-Organized InGaAs Quantum Rings -- Fabrication and Spectroscopy

    OpenAIRE

    Lorke, Axel; García Martínez, Jorge Manuel; García Martínez, Jorge Manuel; Blossey, Ralf; Luyken, Richard Johannes; Petroff, Pierre M.

    2003-01-01

    13 páginas.-- The written version of the plenary and invited lectures of the Spring Meeting of the Condensed Matter Physics section of the Deutsche Physikalische Gesellschaft held from March 24 to 28, 2003 in Dresden, Germany.-- Kramer, Bernhard (Ed.).

  7. Analysis of potential energy saving strategies in a Bangkok school building. With CD-ROM; Analyse von Energieeinsparpotentialen am Beispiel einer Schule in Bangkok

    Energy Technology Data Exchange (ETDEWEB)

    Temming, H.V.

    2000-05-01

    In cooperation with the Gesellschaft fuer technische Zusammenarbeit GTZ, a school building in Thailand was selected for an analysis of potentials for energy saving. The selected school was the New International School of Thailand (NIST) in Bangkok. Energy-relevant data were acquired by measurements, and solutions for more efficient energy supply were developed. Recommendations were made on this basis. This dissertation is also available on CD-ROM. [German] In Zusammenarbeit mit der Gesellschaft fuer technische Zusammenarbeit GTZ wurde als Beispielobjekt eine thailaendische Schule, die New International School of Thailand (NIST) in Bangkok ausgewaehlt. An diesem Objekt wurden die verschiedenen energetischen Messungen durchgefuehrt. Diese wurden bedarfsgerecht ausgewertet. Auf der Basis der Ergebnisse wurden Loesungsmoeglichkeiten fuer eine effizientere Energieversorgung der Schule konstruiert und diese Alternativen wie oben beschrieben bewertet, woraus sich entsprechende Empfehlungen ergeben. Der Aufbau dieser Arbeit stellt sich nun folgendermassen dar: Nachdem in einem ersten Schritt die fuer diesen Kontext wichtigsten Parameter Thailands und des Untersuchungsobjektes dargestellt werden, schliesst sich hieran die Vorstellung verschiedener technische Alternativen zur Erzeugung von Kaelte an, da hier ein Fokus fuer moegliche Energieeinsparungen gesetzt wird. Anschliessend werden einige in der Arbeit verwandte Berechnungsverfahren fuer energetische oder wirtschaftliche Zuammenhaenge sowie eine ausfuehrliche Beschreibung der energetischen 1st-Situation des Untersuchungsobjektes dargestellt. Darauf aufbauend folgt nun die Vorstellung der verschiedenen Energieeinsparpotentiale durch technische und verhaltensinduzierte Optimierungsmassnahmen. Diese Arbeit endet mit der Bewertung aller aufgedeckten Potentiale und einem Gesamtfazit aus der Untersuchung. (Diese Diplomarbeit liegt auch in Form einer CD-ROM vor.) (orig./AKF)

  8. High precision efficiency calibration of a HPGe detector

    International Nuclear Information System (INIS)

    Nica, N.; Hardy, J.C.; Iacob, V.E.; Helmer, R.G.

    2003-01-01

    Many experiments involving measurements of γ rays require a very precise efficiency calibration. Since γ-ray detection and identification also requires good energy resolution, the most commonly used detectors are of the coaxial HPGe type. We have calibrated our 70% HPGe to ∼ 0.2% precision, motivated by the measurement of precise branching ratios (BR) in superallowed 0 + → 0 + β decays. These BRs are essential ingredients in extracting ft-values needed to test the Standard Model via the unitarity of the Cabibbo-Kobayashi-Maskawa matrix, a test that it currently fails by more than two standard deviations. To achieve the required high precision in our efficiency calibration, we measured 17 radioactive sources at a source-detector distance of 15 cm. Some of these were commercial 'standard' sources but we achieved the highest relative precision with 'home-made' sources selected because they have simple decay schemes with negligible side feeding, thus providing exactly matched γ-ray intensities. These latter sources were produced by us at Texas A and M by n-activation or by nuclear reactions. Another critical source among the 17 was a 60 Co source produced by Physikalisch-Technische Bundesanstalt, Braunschweig, Germany: its absolute activity was quoted to better than 0.06%. We used it to establish our absolute efficiency, while all the other sources were used to determine relative efficiencies, extending our calibration over a large energy range (40-3500 keV). Efficiencies were also determined with Monte Carlo calculations performed with the CYLTRAN code. The physical parameters of the Ge crystal were independently determined and only two (unmeasurable) dead-layers were adjusted, within physically reasonable limits, to achieve precise absolute agreement with our measured efficiencies. The combination of measured efficiencies at more than 60 individual energies and Monte Carlo calculations to interpolate between them allows us to quote the efficiency of our

  9. Calibration and validation of a quality assurance system for {sup 90}Sr/{sup 90}Y radiation source trains

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, P [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Weber, W [Novoste GmbH, Huettenallee 237 c, D-47800 Krefeld (Germany); Foerster, A [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Orth, O [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Koehler, B [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany); Seiler, F [Department of Radiation Therapy and Oncology, Freie Universitaet Berlin, Benjamin Franklin University Medical Centre, Hindenburgdamm 30, D-12200 Berlin (Germany)

    2003-03-07

    A quality assurance system (OPTIDOS, PTW-Freiburg) developed for dose rate verification of {sup 90}Sr/{sup 90}Y radiation source trains (RSTs) was calibrated and validated. These source trains are used in the 5-F-BetaCath{sup TM} system (Novoste Corp.) for the treatment of endovascular diseases. The calibration factor of the OPTIDOS system was obtained empirically and is valid for {sup 90}Sr/{sup 90}Y dose rate measurements at the specification point which is located at 2 mm distance from the source axis. A total of 187 OPTIDOS dose rate verifications of the 5-F-BetaCath{sup TM} system were performed in different hospitals. The histogram of the deviation between the manufacturer's dose rate specification and the dose rate measured using the OPTIDOS dosimetry system is Gaussian shaped with {+-}3% relative width and a mean shift of about +2% with respect to the corresponding dose rate specification. Additionally, 128 OPTIDOS dose rate verifications of the new jacketed RST (3.5-F-BetaCath{sup TM}, Novoste Corp.) were performed using the same calibration factor as derived for the 5-F-BetaCath{sup TM} system. Distribution of the deviation between the certified and the measured dose rate is nearly identical in comparison to the histogram of the 5-F-BetaCath{sup TM} system. The mean value of the deviations is shifted by -1.5% with respect to the certified dose rate. In order to compare the results of the calibrated OPTIDOS dosimetry system with a standard measuring method, separate dose rate measurements were performed using electron accelerator calibrated radiochromic films in which calibration is traceable to PTB (Physikalisch Technische Bundesanstalt, Germany). Deviation between both the methods is less than 3.1%. These results confirm that the calibrated OPTIDOS dosimetry system can be considered suitable for quality assurance of both types of RST used in the BetaCath{sup TM} systems.

  10. SU-F-T-64: An Alternative Approach to Determining the Reference Air-Kerma Rate from Extrapolation Chamber Measurements

    International Nuclear Information System (INIS)

    Schneider, T

    2016-01-01

    Purpose: Since 2008 the Physikalisch-Technische Bundesanstalt (PTB) has been offering the calibration of "1"2"5I-brachytherapy sources in terms of the reference air-kerma rate (RAKR). The primary standard is a large air-filled parallel-plate extrapolation chamber. The measurement principle is based on the fact that the air-kerma rate is proportional to the increment of ionization per increment of chamber volume at chamber depths greater than the range of secondary electrons originating from the electrode x_0. Methods: Two methods for deriving the RAKR from the measured ionization charges are: (1) to determine the RAKR from the slope of the linear fit to the so-called ’extrapolation curve’, the measured ionization charges Q vs. plate separations x or (2) to differentiate Q(x) and to derive the RAKR by a linear extrapolation towards zero plate separation. For both methods, correcting the measured data for all known influencing effects before the evaluation method is applied is a precondition. However, the discrepancy of their results is larger than the uncertainty given for the determination of the RAKR with both methods. Results: A new approach to derive the RAKR from the measurements is investigated as an alternative. The method was developed from the ground up, based on radiation transport theory. A conversion factor C(x_1, x_2) is applied to the difference of charges measured at the two plate separations x_1 and x_2. This factor is composed of quotients of three air-kerma values calculated for different plate separations in the chamber: the air kerma Ka(0) for plate separation zero, and the mean air kermas at the plate separations x_1 and x_2, respectively. The RAKR determined with method (1) yields 4.877 µGy/h, and with method (2) 4.596 µGy/h. The application of the alternative approach results in 4.810 µGy/h. Conclusion: The alternative method shall be established in the future.

  11. Measurement of W values for protons, {sup 4}He- and {sup 12}C ions in air, argon and nitrogen; Messung von W-Werten fuer Protonen, {sup 4}He- und {sup 12}C-Ionen in Luft, Argon und Stickstoff

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Jeannine

    2012-06-27

    In particle therapy for cancer the dosimetry of charged-particle radiation is usually performed by measuring the ionization produced in air-filled ionization chambers. The conversion of the reading of ionization chambers into absorbed dose requires W-values, which are defined as the average energy needed to produce an ion pair. Because of the increasing importance of ion therapy and the lack of experimental data for heavy charged particles in air, new measurements of W-values are being carried out at the Physikalisch-Technische Bundesanstalt Braunschweig (PTB) and the Helmholtzzentrum fuer Schwerionenforschung GmbH Darmstadt (GSI). Existing measurements for protons in air indicate an uncertainty of ±4 %. The main goals of the present work are to achieve consistent measurements for protons, helium and carbon ions in air, argon and nitrogen in the energy region of 1 MeV/u up to 7 MeV/u and to reduce the uncertainties. A low rate of 200 incoming ions per second is produced by scattering the primary beam from the accelerators off a thin gold foil at the center of a scattering chamber. At 45 an either side relative to the beam direction, the scattered ions are detected in a semiconductor detector and stopped in a gas-filled ionization chamber. In this way, the number and the energy of the particles entering the active volume of the ionization chamber can be determined using two independent methods. The number of ion pairs produced in the gas volume is determined from the simultaneous measurement of the ionization current collected at the lower electrode of the chamber using a calibrated electrometer. The W-value is calculated from the ionization current, the number and the energy of particles. Furthermore, several corrections like recombination effects, background from beam induced γ-radiation, measurement of the beam stability and gas cleaning are applied and will be discussed in this thesis. The measured W-values tend to be smaller than existing data and Show an

  12. Precision spectroscopy on atomic hydrogen

    International Nuclear Information System (INIS)

    Parthey, Christian Godehard

    2011-01-01

    This Thesis reports on three measurements involving the 1S-2S transition in atomic hydrogen and deuterium conducted on a 5.8 K atomic beam. The transition is excited Doppler-free via two counter-propagating photons near 243 nm. The H/D isotope shift has been determined as Δ∫ exp =670 994 334 606(15) Hz. Comparing with the theoretical value for the isotope shift, excluding the leading nuclear size effect, Δ∫ th =670 999 566.90(66)(60) kHz we confirm, twice more accurate, the rms charge radius difference of the deuteron and the proton as left angle r 2 right angle d - left angle r 2 right angle p =3.82007(65) fm 2 and the deuteron structure radius r str =1.97507(78) fm. The frequency ratio of the 1S-2S transition in atomic hydrogen to the cesium ground state hyperfine transition provided by the mobile cesium fountain clock FOM is measured to be ∫ 1S-2S =2 466 061 413 187 035 (10) Hz which presents a fractional frequency uncertainty of 4.2 x 10 -15 . The second absolute frequency measurement of the 1S-2S transition in atomic hydrogen presents the first application of a 900 km fiber link between MPQ and Physikalisch- Technische Bundesanstalt (PTB) in Braunschweig which we have used to calibrate the MPQ hydrogen maser with the stationary cesium fountain clock CSF1 at PTB. With the result of ∫ 1S-2S =2 466 061 413 187 017 (11) Hz we can put a constraint on the electron Lorentz boost violating coefficients 0.95c (TX) -0.29c (TY) -0.08 c (TZ) =(2.2±1.8) x 10 -11 within the framework of minimal standard model extensions. We limit a possible drift of the strong coupling constant through the ratio of magnetic moments at a competitive level (∂)/(∂t)ln (μ Cs )/(μ B )=-(3.0±1.2) x 10 -15 yr -1 .

  13. Calibration comparative results for X - and gamma ray spectrometry with HPGe and BEGe detectors for a radon reference chamber

    International Nuclear Information System (INIS)

    Zoran, Maria; Paul, Annette; Arnold, Dirk

    2002-01-01

    Inhaled decay products of 222 Rn are the dominant components of the natural radiation exposure being responsible for about 30% of the whole human radioactive exposure. Field instruments for 222 Rn and his progeny monitoring are calibrated in 'radon climate rooms', where it is possible to vary and monitor 222 Rn and the indoor air parameters ( temperature, humidity, ventilation rate, aerosol concentration). German radon reference chamber used was developed and installed at the Physikalisch-Technische Bundesanstalt in order to serve as a metrological standard for radon and his progeny calibration of active and passive, indoor and outdoor radon monitoring devices in air climate. The basic parts of experimental setup for this γ and X -ray spectrometry analysis consists of a γ-X ray source in a lead shield/collimator, the detectors, the electronics necessary for pulse-height analysis (PHA) to obtain energy spectra. For calibrating system with 226 Ra standard sources (multienergy X ray and gamma emitters), two germanium detectors HPGe (12.5 nominal efficiency) and BEGe (22.5 nominal efficiency) were used. Germanium detectors are semiconductor diodes having a P-I-N structure in which the Intrinsic (I) region is sensitive to ionizing radiation, particularly X-rays and gamma rays. The BEGe is designed with an electrode structure that enhances low energy resolution and is fabricated from selected germanium having an impurity profile that improves charge collection (thus resolution and peak shape) at high energies which is really important in analysis of the complex spectra for uranium and finally for 226 Ra. MAESTRO MCA software and GNUPLOT program were used for spectra acquisition and spectra analysis, respectively . The main aim of this paper was to do a comparatively analysis of the detector performances for this radon chamber spectrometric chain. The calibration data analysis includes energy calibrations for both detection systems as well as comparative X and gamma

  14. Quality assurance for MR stereotactic imaging for three Siemens scanners

    International Nuclear Information System (INIS)

    Kozubikova, P.; Novotny, J. Jr.; Kulhova, K.; Mihalova, P.; Tamasova, J.; Veselsk, T.

    2014-01-01

    Quality assurance of stereotactic imaging, especially with MRI (magnetic resonance imaging), is a complex issue. It can be divided in the basic verification and commissioning of a particular new scanner or a new scanning MRI protocol that is being implemented into a clinical practice and the routine quality assurance performed for each single radiosurgical case. The aim of this study was geometric distortion assessment in MRI with a special PTGR (Physikalisch-Technische Gesellschaft fuer Radiologie - GmbH, Tuebingen, Germany) target phantom. PTGR phantom consists of 21 three-dimensional cross-hairs filled with contrast medium. Cross hairs are positioned at known Leksell coordinates with a precision of better than 0.1 mm and covering the whole stereotactic space. The phantom can be fixed in the Leksell stereotactic frame and thus stereotactic imaging procedures can be reproduced following exactly the same steps as for a real patient, including also the stereotactic image definition in the Leksell GammaPlan. Since the geometric position (stereotactic coordinates) of each cross-hair is known based on the construction of the phantom, it can be compared with the actual measured Leksell coordinates based on the stereotactic MRI. Deviations between expected and actual coordinates provide information about the level of distortion. The measured distortions proved satisfactory accuracy precision for stereotactic localization at 1.5 T Siemens Magnetom Avanto scanner, Siemens Magnetom Symphony scanner and 3T Siemens Magnetom Skyra scanner (Na Homolce Hospital, Prague). The mean distortion for these MR scanners for standard imaging protocol (T1 weighted 3D images) were 0.8 mm, 1.1 mm and 1.1 mm and maximum distortions were 1.3 mm, 1.9 mm and 2.2 mm, respectively.There was detected dependence of the distortions on the slice orientation and the type of imaging protocol. Image distortions are also property of each particular scanner, the worst distortion were observed for 3T

  15. De Max-Planck medaille

    NARCIS (Netherlands)

    Heijmans, H.G.; van Woerkom, P.Th.L.M.; Ankersmit, W.; Hagman, R.; Heijmans, H.G.; Olsder, G.J.; van de Schootbrugge, G.

    2017-01-01

    De Max-Planck-Medaille is een onderscheiding die sinds 1929 jaarlijks wordt uitgereikt door de toentertijd grootste vereniging van natuurkundigen ter wereld: de Deutsche Physikalische Gesellschaft. Het is als het ware de Nobelprijs voor de theoretische natuurkunde, volgens de natuurkundigen zelf. In

  16. Physikalische, chemische und mechanische Untersuchungen an zementierten radioaktiven Abfallprodukten

    OpenAIRE

    Aßmann, D.

    1987-01-01

    Radioactive wastes in liquid, gas or solid forms are produced by the recycling of fuel rods. Liquid middle active waste (MAW) will be fixed in 200 or 400 1 barrels. This work examins the influence of middle active waste on the hydration of cement. The change of the mechanical and physical capacities of the MAW contained products is also analysed. Experiments were performed to determine if cesium and strontium are bounded in the hydration products of cement. The hydration of cement changes wit...

  17. eLearning-radiology.com. Sustainability for quality assurance; eLearning-radiology.com. Nachhaltigkeit im Sinne der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, D. [Tuebingen Univ. (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Talanow, R. [Cleveland Clinic, Cleveland, OH (United States). Abt. fuer Nuklearmedizin; Uder, M. [Erlangen-Nuernberg Univ. (Germany). Inst. fuer Diagnostische Radiologie; Grunewald, M. [Erlangen-Nuernberg Univ. (Germany). Nuklearmedizinische Klinik

    2009-04-15

    Purpose: The aim of the study was to analyze the availability of published radiological e-learning tools and to establish a solution for quality assurance. Materials and Methods: Substantial pubmed research was performed to identify radiological e-learning tools. 181 e-learning programs were selected. As examples two databases expanding their programs with external links, Compare (n = 435 external links) and TNT-Radiology (n = 1078 external links), were evaluated. A concept for quality assurance was developed by an international taskforce. Results: At the time of assessment, 56.4 % (102/181) of the investigated e-learning tools were accessible at their original URL. A subgroup analysis of programs published 5 to 8 years ago showed significantly inferior availability to programs published 3 to 5 years ago (p < 0.01). The analysis of external links showed 49.2 % and 61.0 % accessible links for the programs Compare (published 2003) and TNT-Radiology (published 2006), respectively. As a consequence, the domain www.eLearning-radiology.com was developed by the taskforce and published online. This tool allows authors to present their programs and users to evaluate the e-learning tools depending on several criteria in order to remove inoperable links and to obtain information about the complexity and quality of the e-learning tools. (orig.)

  18. Temperature documentation - instrument for quality assurance; Temperaturdokumentation - Instrument der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Hegglin, A [Wurm AG, Winterthur (Switzerland)

    2000-10-01

    Important inspection points of a HACCP concept are the temperatures. On the basis of the demands for a systematic temperature documentation, the application of control systems and instruments is described by several examples. (orig.) [German] Wichtige Kontrollpunkte eines HACCP-Konzepts sind die Temperaturen. Ausgehend von den Anforderungen, die an eine systematische Temperaturedokumentation gestellt werden, wird der Einsatz geeigneter Regel- und Ueberwachungsgeraete an mehreren Beispielen erlaeutert. (orig.)

  19. Physik für Studenten der Natur- und Technikwissenschaften

    CERN Document Server

    Stroppe, Heribert

    1999-01-01

    Dieses bewährte Lehrbuch vermittelt in kompakter Form einen Überblick über das gesamte physikalische Grundlagenwissen. Die inhaltiche Gliederung nach den Grundmodellen der Physik : Teilchen, Kontinua, Wärme, Felder, Wellen, Quanten, und die didaktische Aufbereitung des Lehrstoffes ermöglichen eine rationelle Wissensaneignung. [...

  20. Deep Learning For Sequential Pattern Recognition

    OpenAIRE

    Safari, Pooyan

    2013-01-01

    Projecte realitzat en el marc d’un programa de mobilitat amb la Technische Universität München (TUM) In recent years, deep learning has opened a new research line in pattern recognition tasks. It has been hypothesized that this kind of learning would capture more abstract patterns concealed in data. It is motivated by the new findings both in biological aspects of the brain and hardware developments which have made the parallel processing possible. Deep learning methods come along with ...

  1. Robust interferometer for the routing of light beams carrying orbital angular momentum

    CSIR Research Space (South Africa)

    Lavery, MPJ

    2011-09-01

    Full Text Available , but checking for N states requires at least N photons [8]. Recently it has been shown that two diffractive optical elements can New Journal of Physics 13 (2011) 093014 1367-2630/11/093014+06$33.00 ? IOP Publishing Ltd and Deutsche Physikalische Gesellschaft...

  2. Technisch lego met een Duplo-interface

    NARCIS (Netherlands)

    Pimentel, A.; Schipper, D.

    2008-01-01

    Daedalus is een ontwerpflow op systeemniveau waarmee techneuten snel kunnen experimenteren met verschillende multiprocessorarchitecturen tijdens de vroege stadia van het ontwerptraject. Het is het resultaat van tien jaar onderzoek en ontwikkeling binnen de Progress-projecten Artemis en Artemisia.

  3. Synovial sarcoma of the foot; Synovialsarkom des Fusses

    Energy Technology Data Exchange (ETDEWEB)

    Beus, J. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Kreitner, K.F. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Rompe, J.D. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Orthopaedie; Riehle, H.M. [Mainz Univ. (Germany). Inst. fuer Pathologie

    1996-09-01

    The case of a 29 year-old female patient who had experienced pain in the right midfoot for 5 years which was diagnosed as a degenerative or rheumatic change and treated by physiotherapy and medication. By means of magnetic resonance imaging we identified a soft-tissue tumor of the midfoot. Histology provided the findings of a monophasic fibrous synovial sarcoma. The case history is reported together with a presentation of the disease and its radiological diagnosis. (orig.) [Deutsch] Es wird ueber den Fall einer 29jaehrigen Patientin berichtet, die 5 Jahre lang wegen Schmerzen im rechten Mittelfuss unter der Diagnose degenerativer oder rheumatischer Veraenderungen physikalisch und medikamentoes behandelt wurde. Magnetresonanztomographisch wurde ein Weichteiltumor des Mittelfusses diagnostiziert. Die histologische Untersuchung erbrachte den Befund eines monophasisch-fibroesen Synovialsarkoms. Mit der Kasuistik verbunden ist eine Darstellung des Krankheitsbildes und dessen radiologischer Diagnostik. (orig.)

  4. Quality management for noble gas trace analysis; Qualitaetssicherung bei der Edelgasspurenanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, S.; Konrad, M.; Kumberg, T.; Schlosser, C. [Bundesamt fuer Strahlenschutz (BfS), Freiburg (Germany); Gohla, H. [Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO), Vienna International Centre, Vienna (Austria). Preparatory Commission

    2014-01-20

    The Federal Office for Radiation Protection operates measurement systems to determine the activity concentrations of Krypton-85 and Xenon-133 in air samples since the early 70s. Certified standards with stable noble gas admixtures are still missing for quality assurance (certified activity concentrations). The Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) is currently establishing a global noble gas monitoring network for the verification of compliance with the Treaty. In cooperation with CTBTO the BfS currently develops concepts of quality assurance for noble gas measurements. Opportunities for quality assurance without using certified standards are discussed by comparisons between individual laboratories and internal audits. The results from the first CTBTO laboratory intercomparison with synthetic radioxenon samples look very promising.

  5. Experience with the operation of a solar central heating system in Friedrichshafen/Wiggenhausen-Sued; Betriebserfahrungen mit der solaren Nahwaermeversorgung in Friedrichshafen/Wiggenhausen-Sued

    Energy Technology Data Exchange (ETDEWEB)

    Stanzel, B.; Gawantka, F. [Technische Werke Friedrichshafen GmbH, Friedrichshafen (Germany)

    1998-12-31

    The ideas, concepts and pilot plants for solar central heating systems developed by the Institute for Thermodynamics and Thermal Engineering of Stuttgart University were implemented by the Steinbeis-Transfer Centre for Energy, Building and Solar Engineering. In order to improve the economic efficiency of solar central heating with long-term storage a pilot plant with a heat storage tank of 12,000 cubic metres was built in Wiggenhausen-Sued. The `Technische Werke Friedrichshafen` (TWF) is in charge of the project `Solar City Wiggenhausen-Sued`. This company built the plant and also operates and maintains it. (orig.) [Deutsch] Die Ideen, Konzepte und erste Pilotanlagen zur solaren Nahwaerme werden seit Mitte der achtziger Jahre vom Institut fuer Thermodynamik und Waermetechnik (ITW) der Universitaet Stuttgart entwickelt und vom Steinbeis-Transferzentrum Energie-, Gebaeude- und Solartechnik umgesetzt. Um die solare Nahwaermeversorgung mit Langzeit-Waermespeicher der Wirtschaftlichkeit etwas naeher zu bringen, wurde eine Pilotanlage mit einem 12.000 m{sup 3} grossen Waermespeicher in Wiggenhausen-Sued gebaut. Mit diesem Pilotprojekt soll neben der technischen Durchfuehrbarkeit die Kostendegression durch steigende Anlagengroesse nachgewiesen werden. Als Energiedienstleistungsunternehmen hat die Technische Werke Friedrichshafen GmbH (TWF) die technische und kaufmaennische Durchfuehrung des Projektes `Solarstadt Wiggenhausen-Sued` uebernommen. Sie errichtete, betreibt und wartet die Anlage. (orig.)

  6. Rozważania kosmologiczne na temat ogólnej teorii względności

    Directory of Open Access Journals (Sweden)

    Albert Einstein

    2017-12-01

    Full Text Available A. Einstein, “Kosmologische Betrachtungen zur allgemeinen Relativitätstheorie” (“Cosmological considerations on the general theory of relativity”, Sitzung der Physikalisch-mathematischen Klasse vom 8. Februar 1917, „Sitzungsberichte der Preußischen Akad. d. Wissenschaften, 1917”, pp. 142–152. Translated to Polish from original German work by Robert Janusz.

  7. Plenary lectures of the divisions semiconductor physics, thin films, dynamics and statistical physics, magnetism, metal physics, surface physics, low temperature physics

    International Nuclear Information System (INIS)

    Roessler, U.

    1992-01-01

    This volume contains a selection of plenary and invited lectures of the Solid State Division spring meeting of the DPG (Deutsche Physikalische Gesellschaft) 1992 in Regensburg. The constribution come mainly from five fields of the physics of condensed matter: doped fullerenes and high Tc superconductors, surfaces, time-resolved on nonlinear optics, polymer melts, and low-dimensional semiconductor systems. (orig.)

  8. Herkommer zum Hinschauen

    OpenAIRE

    Schilling, Jörg

    2011-01-01

    Tagung: Moderne Architektur exemplarisch. Hans Herkommer (1887-1956). Technische Universität Kaiserslautern, Lehrgebiet Geschichte und Theorie der Architektur. Prof. Dr. phil. Matthias Schirren. 28.-29. Oktober 2010

  9. EURADOS intercomparison 2012 for neutron dosemeters

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Chevallier, M.A.; Cruz-Suarez, R.; Luszik-Bhadra, M.; Mayer, S.; Thomas, D.J.; Tanner, R.; Vanhavere, F.

    2014-11-01

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ( 252 Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ( 252 Cf at 45 ) or for simulated workplace fields ( 252 Cf(D 2 O) or 252 Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection principle on which the

  10. Development and application of cryogenic radiometry with hard X-rays

    International Nuclear Information System (INIS)

    Gerlach, Martin

    2008-01-01

    To establish cryogenic radiometry with hard X-ray radiation for photon energies of up to 60 keV, a novel type of cavity absorber had to be developed for the cryogenic radiometer SYRES I, which is deployed by the Physikalisch-Technische Bundesanstalt (PTB) as primary standard detector at the electron storage ring BESSY II. This new type of cavity absorber allows for the complete absorption of hard X-ray radiation in combination with an appropriate sensitivity and an adequate time constant for the measurement of synchrotron radiation at BESSY II. As the process of fabrication of different types of absorbers is very time-consuming, the interaction of hard X-ray radiation with different absorber materials and geometries was studied intensively by using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a wavelength shifter beamline at BESSY II with a calibrated energy dispersive detector. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in a cavity absorber with a gold base 550 μm in thickness and a cylindrical shell made of copper 90 μm in thickness to reduce losses caused by fluorescence and scattered radiation. Monochromatized synchrotron radiation of high spectral purity was then used to calibrate semiconductor photodiodes, which can be used as compact and inexpensive secondary standard detectors, against a cryogenic radiometer, covering the entire photon energy range of three beamlines from 50 eV to 60 keV with relative uncertainties of less than 0.5 %. Furthermore the spatial homogeneity of the spectral responsivity, the transmittance and the linearity of the photodiodes was investigated. Through a direct comparison of the free-air ionization chamber PK100, a primary detector standard of PTB used in dosimetry, and the cryogenic radiometer SYRES

  11. Labeling of mesenchymal stem cells for MRI with single-cell sensitivity

    Directory of Open Access Journals (Sweden)

    Ariza de Schellenberger A

    2016-04-01

    Full Text Available Angela Ariza de Schellenberger,1 Harald Kratz,1 Tracy D Farr,2,3 Norbert Löwa,4 Ralf Hauptmann,1 Susanne Wagner,1 Matthias Taupitz,1 Jörg Schnorr,1 Eyk A Schellenberger1 1Department of Radiology, 2Department of Experimental Neurology, Center for Stroke Research Berlin, Charité – Universitätsmedizin Berlin, Berlin, Germany; 3School of Life Sciences, University of Nottingham, Medical School, Nottingham, UK; 4Department of Biomagnetic Signals, Physikalisch-Technische Bundesanstalt Berlin, Berlin, Germany Abstract: Sensitive cell detection by magnetic resonance imaging (MRI is an important tool for the development of cell therapies. However, clinically approved contrast agents that allow single-cell detection are currently not available. Therefore, we compared very small iron oxide nanoparticles (VSOP and new multicore carboxymethyl dextran-coated iron oxide nanoparticles (multicore particles, MCP designed by our department for magnetic particle imaging (MPI with discontinued Resovist® regarding their suitability for detection of single mesenchymal stem cells (MSC by MRI. We achieved an average intracellular nanoparticle (NP load of >10 pg Fe per cell without the use of transfection agents. NP loading did not lead to significantly different results in proliferation, colony formation, and multilineage in vitro differentiation assays in comparison to controls. MRI allowed single-cell detection using VSOP, MCP, and Resovist® in conjunction with high-resolution T2*-weighted imaging at 7 T with postprocessing of phase images in agarose cell phantoms and in vivo after delivery of 2,000 NP-labeled MSC into mouse brains via the left carotid artery. With optimized labeling conditions, a detection rate of ~45% was achieved; however, the experiments were limited by nonhomogeneous NP loading of the MSC population. Attempts should be made to achieve better cell separation for homogeneous NP loading and to thus improve NP

  12. Development and application of cryogenic radiometry with hard X-rays; Entwicklung und Anwendung der Kryoradiometrie mit harter Roentgenstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Gerlach, Martin

    2008-06-06

    To establish cryogenic radiometry with hard X-ray radiation for photon energies of up to 60 keV, a novel type of cavity absorber had to be developed for the cryogenic radiometer SYRES I, which is deployed by the Physikalisch-Technische Bundesanstalt (PTB) as primary standard detector at the electron storage ring BESSY II. This new type of cavity absorber allows for the complete absorption of hard X-ray radiation in combination with an appropriate sensitivity and an adequate time constant for the measurement of synchrotron radiation at BESSY II. As the process of fabrication of different types of absorbers is very time-consuming, the interaction of hard X-ray radiation with different absorber materials and geometries was studied intensively by using the Monte Carlo simulation code Geant4. The accuracy of the simulations was verified comparing them to scattering experiments performed at a wavelength shifter beamline at BESSY II with a calibrated energy dispersive detector. It was shown that Geant4 describes the photo-effect, including fluorescence as well as Compton- and Rayleigh scattering, with high accuracy. The simulations and experiments resulted in a cavity absorber with a gold base 550 {mu}m in thickness and a cylindrical shell made of copper 90 {mu}m in thickness to reduce losses caused by fluorescence and scattered radiation. Monochromatized synchrotron radiation of high spectral purity was then used to calibrate semiconductor photodiodes, which can be used as compact and inexpensive secondary standard detectors, against a cryogenic radiometer, covering the entire photon energy range of three beamlines from 50 eV to 60 keV with relative uncertainties of less than 0.5 %. Furthermore the spatial homogeneity of the spectral responsivity, the transmittance and the linearity of the photodiodes was investigated. Through a direct comparison of the free-air ionization chamber PK100, a primary detector standard of PTB used in dosimetry, and the cryogenic radiometer

  13. Gonad doses in radiotherapy. Phantom measurement in mammary carcinomas, Morbus Hodgkin, seminomas, hypernephromas, and rhabdomyosarcomas of the thigh

    International Nuclear Information System (INIS)

    Liebstueckel, L.

    1979-01-01

    The gonad doses in the therapy of malignant diseases were determined under defined conditions with the aid of a 60 Co and a 137 Cs irradiation appliance using an Alderson and paraffin phantom each. The measurements were carried out with a condiometer by Physikalisch-Technische Werkstaetten, Freiburg. Two different types of condensator chambers with a measuring range 15 mR to 8 R were used. In the irradiation of mammary carcinoma using the Alderson phantom with two tangential stationary fields the ovarian dose was 0.49 to 1.05 per mille, the testicular dose 0.3 to 0.47 per mille of the maximum irradiated dose. If mammary carcinomas are irradiated using a Caesa-Gammatron, the ovarian dose varies from 0.04 to 0.78 per mille within the five fields, the testicular dose from 0.01 to 0.13 per mille. For these measurements the paraffin phantom was used. If the radiation technique was somewhat modified, the ovaries (testes) of the Alderson phantom irradiated for Hodgkin's disease received 7 (4.7) per mille from irradiation of the thoracal field and 4.6 (3.2) per mille from irradiation of the mediastinal field. Irradiation of the abdominal field produced doses for the female and male gonads of 520 resp. 47.2 per mille. On irradiation of the para-aortic field, the ovaries and testes received doses of 8 resp. 4.6 per mille. Irradiation of the Alderson phantom for seminoma involved testicular doses between 29.1 and 3.1 per mille, depending on the size of the field and its distance from the gonads. Hypernephroma irradiation was carried out on the Alderson phantom with two pendular fields. The ovaries received between 3.7 and 14 per mille and the testes between 2.3 and 3.3 per mille of the focal dose. In irradiation for rhabdomyosarcoma, simulated with the paraffin phantom, the ovarian doses ranged between 5.5 and 11.9 per mille. The male gonad dose rose to values between 36.5 and 458 per mille of the focal dose. (orig./MG) [de

  14. Precision spectroscopy on atomic hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Parthey, Christian Godehard

    2011-12-15

    This Thesis reports on three measurements involving the 1S-2S transition in atomic hydrogen and deuterium conducted on a 5.8 K atomic beam. The transition is excited Doppler-free via two counter-propagating photons near 243 nm. The H/D isotope shift has been determined as {delta}{integral}{sub exp}=670 994 334 606(15) Hz. Comparing with the theoretical value for the isotope shift, excluding the leading nuclear size effect, {delta}{integral}{sub th}=670 999 566.90(66)(60) kHz we confirm, twice more accurate, the rms charge radius difference of the deuteron and the proton as left angle r{sup 2} right angle {sub d}- left angle r{sup 2} right angle {sub p}=3.82007(65) fm{sup 2} and the deuteron structure radius r{sub str}=1.97507(78) fm. The frequency ratio of the 1S-2S transition in atomic hydrogen to the cesium ground state hyperfine transition provided by the mobile cesium fountain clock FOM is measured to be {integral}{sub 1S-2S}=2 466 061 413 187 035 (10) Hz which presents a fractional frequency uncertainty of 4.2 x 10{sup -15}. The second absolute frequency measurement of the 1S-2S transition in atomic hydrogen presents the first application of a 900 km fiber link between MPQ and Physikalisch- Technische Bundesanstalt (PTB) in Braunschweig which we have used to calibrate the MPQ hydrogen maser with the stationary cesium fountain clock CSF1 at PTB. With the result of {integral}{sub 1S-2S}=2 466 061 413 187 017 (11) Hz we can put a constraint on the electron Lorentz boost violating coefficients 0.95c{sub (TX)}-0.29c{sub (TY)}-0.08 c{sub (TZ)}=(2.2{+-}1.8) x 10{sup -11} within the framework of minimal standard model extensions. We limit a possible drift of the strong coupling constant through the ratio of magnetic moments at a competitive level ({partial_derivative})/({partial_derivative}t)ln ({mu}{sub Cs})/({mu}{sub B})=-(3.0{+-}1.2) x 10{sup -15} yr{sup -1}.

  15. The second EURADOS intercomparison of national network systems used to provide early warning of a nuclear accident

    International Nuclear Information System (INIS)

    Saez-Vergara, J. C.; Thompson, I. M. G.; Gurriaran, R.; Dombrowski, H.; Funck, E.; Neumaier, S.

    2007-01-01

    In 1999 and 2002, the EURADOS Working Group on Environmental Monitoring organised two European intercomparison exercises of national network systems used to provide early warning in case of a nuclear accident. In total, 12 European countries, represented by more than 40 scientists, participated in these two intercomparisons with more than 35 different dose rate detectors. In addition, an in situ gamma spectrometry intercomparison was performed by a group of European scientists during the 2002 exercise. Results of these spectrometry measurements will be reported elsewhere. This report summarises the results of the second intercomparison, performed in 2002, at the environmental dosimetry facilities of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The unique combination of the ultra-low background Underground Laboratory (UDO) and two free-field sites (a floating platform on a lake showing an almost pure cosmic radiation field and a free-field gamma ray irradiation facility) provide the particular opportunity to precisely quantify the inherent background of the detectors and to calibrate them almost free of any background and traceable to PTB's primary standards. In addition, the intercomparison comprised investigations on the energy and dose rate dependence of the detectors' response to gamma radiation as well as on the response to cosmic radiation. Finally, the sensitivity of the detector systems to small dose rate variations, similar to that caused by a passing overhead radioactive plume, was studied under realistic free-field conditions. Following the Council Directive 96/29/EURATOM, the participants of the 2002 intercomparison were asked to report their results in terms of the operational quantity ambient dose equivalent, H*(10). Although the verification of the individual calibrations showed smaller discrepancies than those in the 1999 intercomparison, in a few cases, these discrepancies would be still unacceptably high in the case of a real

  16. Goal Driven Software Project Risk Management: Design eines COSO II-ERM-basierten Domain Models

    OpenAIRE

    Schiessl, Christoph

    2016-01-01

    von Christoph Schiessl Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Diplomarbeit, 2016

  17. Wolframcarbid/Silber-Kontaktwerkstoffe durch Gasdruckinfiltration

    OpenAIRE

    Stadler, Thomas

    2017-01-01

    von Thomas Stadler Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Diplomarbeit, 2017

  18. How Blockchain technology and other innovations change(d) the future of banking

    OpenAIRE

    Semenchenko, Mariia

    2016-01-01

    von Mariia Semenchenko Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Masterarbeit, 2016

  19. The Role of Trust in Participatory Processes

    OpenAIRE

    Dobrova, Anna

    2017-01-01

    von Anna Dobrova Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Diplomarbeit, 2017

  20. Ab-initio Rechnungen für Th dotiertes Kalziumfluorid (CaF2)

    OpenAIRE

    Dessovic, Philipp

    2016-01-01

    von Philipp Dessovic Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Diplomarbeit, 2016

  1. Ontology matchmaking of product ramp-up knowledge in manufacturing industries - How to transfer a cake-baking recipe between bakeries

    OpenAIRE

    Willmann, Roland

    2016-01-01

    von Roland Willmann Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Dissertation, 2016

  2. Quality assurance, quality control from an operating company's point of view; Qualitaetssicherung aus Sicht eines Betreibers

    Energy Technology Data Exchange (ETDEWEB)

    Hoehne, Heiko [E.ON New Build and Technology, Gelsenkirchen (Germany)

    2010-07-01

    With a last years output of over 39 TWh the CCGT power stations participated with 14 % on the total power produced within E.ON. Within the E.ON CCGT Fleet there are more than 86 gas turbines with an output above 10 MW. Due to fast growing internationalism and globalism within the manufacturing and erection of gas turbines and their auxiliarities E.ON has started an expansive QA-Program especially with focus on their F-Class engines. Due to reduced trained personnel and lack of expertise at the owner and the potential service provider (OEM) for older technology QA becomes more and more important. We as the owner, together with the OEM, try to challenge these needs by systematically gathering causes for damage and carrying out resulting upgrades within the design and the service management. (orig.)

  3. Methods and models in mathematical biology deterministic and stochastic approaches

    CERN Document Server

    Müller, Johannes

    2015-01-01

    This book developed from classes in mathematical biology taught by the authors over several years at the Technische Universität München. The main themes are modeling principles, mathematical principles for the analysis of these models, and model-based analysis of data. The key topics of modern biomathematics are covered: ecology, epidemiology, biochemistry, regulatory networks, neuronal networks, and population genetics. A variety of mathematical methods are introduced, ranging from ordinary and partial differential equations to stochastic graph theory and  branching processes. A special emphasis is placed on the interplay between stochastic and deterministic models.

  4. Zeolithhaltige Katalysatoren für die Nachbehandlung von sauerstoffreichem Abgas aus Verbrennungsmotoren

    OpenAIRE

    Scharr, Detlef

    2007-01-01

    Im Rahmen dieser Arbeit wurden neuartige Katalysatoren für die Minderung der Stickoxide in sauerstoffreichem Abgas aus Verbrennungsmotoren untersucht. Als Katalysatoren wurden physikalische Mischungen aus unterschiedlichen Zeolithen und Übergangsmetalloxiden verwendet. Der Zeolith soll die Kohlenwasserstoffe im Abgas zu einem geeigneten Reduktionsmittel aufbereiten, das die Stickoxide am Übergangsmetall wirksam reduziert. Da über das Zusammenwirken der beiden Materialien in der Mischung ...

  5. BAUHAUS MUSEUM DESSAU

    OpenAIRE

    Malík, Andrej

    2016-01-01

    von Andrej Malík Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprueft Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers Technische Universität Wien, Univ., Diplomarbeit, 2016

  6. Environmental risk limits for imidacloprid

    NARCIS (Netherlands)

    Posthuma-Doodeman CJAM; SEC

    2008-01-01

    Dit rapport geeft milieurisicogrenzen voor het insecticide imidacloprid in water. Milieurisicogrenzen zijn de technisch-wetenschappelijke advieswaarden voor de uiteindelijke milieukwaliteitsnormen in Nederland. De milieurisicogrenzen zijn afgeleid volgens de methodiek die is voorgeschreven

  7. Environmental risk limits for lambda-cyhalothrin

    NARCIS (Netherlands)

    Leeuwen LC van; Vos JH; Mensink BJWG; SEC

    2008-01-01

    Dit rapport geeft milieurisicogrenzen voor het insecticide lambda-cyhalothrin in water en sediment. Milieurisicogrenzen zijn de technisch-wetenschappelijke advieswaarden voor de uiteindelijke milieukwaliteitsnormen in Nederland. De milieurisicogrenzen zijn afgeleid volgens de methodiek die

  8. Perspectieven in de robotica : Overzicht van samenwerkende disciplines

    NARCIS (Netherlands)

    Horne, C.; De Wolf, S.; Abd El Ghany, M.; Dumay, A.

    1986-01-01

    Symposium gehouden op 20 juni 1986 in het gebouw van de afdeling der Elektrotechniek, Technische Hogeschool Delft, georganiseerd door de IEEE Student Branch Delft, in samenwerking met IEEE Benelux Section NERG en KIvI

  9. Colloquium on High Resolution Molecular Spectroscopy (16th) Held in Universite de Bourgogne, Dijon, France on 6-10 September 1999

    Science.gov (United States)

    1999-09-28

    Chimica Fisica e Photophysique Mol6culaire, Physikalische Chemnie, Inorganica, Universit6 de Paris-Sud, ETH Zentrum, Universitý, de Bologna, Orsay... de la Materia, Consejo Superior de Investigaciones Cientificas, Serrano 123, 28006 Madrid, Spain; C. CLAVEAU and A. VALENTIN, Laboratoire de Physique...Cedex, France; J. C. LOPEZ and S. BLANCO, Departamento de Quimica- Fisica , Facultad de Ciencias, Universitad de Valladolid, 47071 Valladolid, Spain; A

  10. Sorption und Verbreitung per- und polyfluorierter Chemikalien (PFAS) in Wasser und Boden

    OpenAIRE

    Gellrich, Vanessa

    2014-01-01

    PFAS (= Perfluoroalkyl and Polyfluoroalkyl Substances) sind persistente organische Spurenstoffe, die weltweit in verschiedenen Umweltkompartimenten nachgewiesen werden konnten. Im Rahmen dieser Dissertation sollte die Frage geklärt werden, wie die physikalisch-chemischen Eigenschaften der PFAS - besonders ihre Sorption am Boden - ihr Verhalten und ihre Verbreitung in der Umwelt beeinflussen. Dazu wurde zunächst eine Messmethode entwickelt, optimiert und validiert, mit der 17 per- und polyf...

  11. Natural and construction materials and plant products. Raw materials, constructional physics, design and construction. 2. upd. and enl. ed.; Natuerliche und pflanzliche Baustoffe. Rohstoff - Bauphysik - Konstruktion

    Energy Technology Data Exchange (ETDEWEB)

    Holzmann, Gerhard; Wangelin, Matthias; Bruns, Rainer

    2012-07-01

    The book discusses all relevant renewable constructional materials made from fibre or dyeing plants along with their physical and chemical fundamentals. Protection of resources, environmental protection, and pollutants in constructional materials are gone into as well. [German] Dieses Buch behandelt alle wichtige nachwachsenden, pflanzlichen Baustoffe aus Faser- und Faerberpflanzen sowie dazugehoerige physikalische und chemische Grundlagen. Angesprochen werden auch Ressourcen- und Umweltschutz sowie Schadstoffe aus Bauprodukten.

  12. Environmental risk limits for antimony

    NARCIS (Netherlands)

    van Leeuwen LC; Aldenberg T; SEC; mev

    2012-01-01

    Dit rapport geeft milieurisicogrenzen voor antimoon in (grond)water, sediment, en bodem. Milieurisicogrenzen zijn de technisch-wetenschappelijke advieswaarden voor de uiteindelijke milieukwaliteitsnormen in Nederland. De milieurisicogrenzen voor antimoon zijn gebaseerd op de uitkomsten van de EU

  13. Environmental risk limits for acrolein

    NARCIS (Netherlands)

    Bodar CWM; SEC

    2008-01-01

    Dit rapport geeft milieurisicogrenzen voor acroleine in (grond)water, bodem en lucht. Milieurisicogrenzen zijn de technisch-wetenschappelijke advieswaarden voor de uiteindelijke milieukwaliteitsnormen in Nederland. De milieurisicogrenzen voor acroleine zijn gebaseerd op de uitkomsten van de EU

  14. Nieuwe technieken om spuiwater te zuiveren zijn veelbelovend (interview met o.a. Erik van Os)

    NARCIS (Netherlands)

    Arkesteijn, M.; Os, van E.A.

    2012-01-01

    TNO en Wageningen UR Glastuinbouw hebben samen een proefproject gedaan met twee veelbelovende technieken om spuiwater te zuiveren: omgekeerde osmose en membraandestillatie. Deze test vond plaats bij Olij Rozen in De Kwakel. Technisch gezien voldoen beide technieken.

  15. Absorption of formaldehyde in water

    NARCIS (Netherlands)

    Winkelman, Jozef Gerhardus Maria

    2003-01-01

    Deze dissertatie beschrijft theoretisch en experimenteel werk aan de absorptie van formaldehyde in water. Met resultaten hiervan zijn chemisch-technische modellen ontwikkeld voor de beschrijving en optimalisatie van industriële formaldehydeabsorbeurs. Deze samenvatting geeft eerst algemene

  16. Saksamaal Müncheni tehnikaülikoolis / Tuuliki Tõiste, Katri Mägi

    Index Scriptorium Estoniae

    Tõiste, Tuuliki

    2014-01-01

    Erasmuse programmi toel viibiti 28.11-02.12. 2011 koolituslähetusel Müncheni tehnikaülikooli (Technische Universität München, TUM) korraldatud rahvusvahelisel nädalal, kus raamatukogutöötajatele oli eraldi programm

  17. From cybercrime to cyborg crime : An exploration of high-tech cybercrime, offenders and victims through the lens of Actor-Network Theory

    NARCIS (Netherlands)

    van der Wagen, Wytske

    2018-01-01

    Universiteiten die worden gehackt, computersystemen die worden gegijzeld of tot ‘zombies’ gemaakt, servers van Internetproviders die worden gebombardeerd, we worden bijna dagelijks wel geconfronteerd met cybercrime en haar gevolgen. Deze meer technische vormen van criminaliteit wijken op

  18. Comparative evaluation of power generation systems with integrated gasification of biomass; Vergleich von Systemen zur Stromerzeugung mit integrierter Biomassevergasung

    Energy Technology Data Exchange (ETDEWEB)

    Roesch, C [Forschungszentrum Karlsruhe (Germany); Kaltschmitt, M [Stuttgart Univ. (Germany)

    1998-09-01

    Gasification of biomass followed by power generation from the lean product gas can make a significant contribution to power generation without affecting the climate or environment. It is made even more interesting by the high efficiencies and promising pollution ratings that can be achieved. To make full use of this technology, some technical problems still require solving, and some non-technical obstacles need to be removed. (orig./SR) [Deutsch] Zusammenfassend kann festgehalten werden, dass die Biomassevergasung mit anschliessender Verstromung des Schwachgases einen nennenswerten Beitrag zu einer umwelt- und klimavertraeglicheren Energiebereitstellung in Europa leisten kann. Dies gilt insbesondere vor dem Hintergrund der erreichbaren hohen Stromwirkungsgrade und der vielversprechenden Umweltkenngroessen, durch die diese Technik gekennzeichnet ist. Um die Vorteile der Biomassevergasung realisieren zu koennen, muessen jedoch noch verschiedene technische Probleme geloest und nicht technische Hindernisse aus dem Weg geraeumt werden. (orig./SR)

  19. Österreichischer Muster-Leistungskatalog Physikalische Medizin – empirische Grundlagen zur Wirksamkeit der Inhalte [Austrian catalogue of services of physical medicine – empirical basis of the effectiveness of the contents

    Directory of Open Access Journals (Sweden)

    Wilbacher, Ingrid

    2013-07-01

    bei einigen mit Schmerz verbundenen Indikationen. Für Mittel- und Hochfrequenztherapie wurden widersprüchliche Studienergebnisse gefunden.Thermische Therapieanwendungen zeigen im Vergleich zur Placeboanwendung wenig Wirksamkeitsunterschied. Schlussfolgerung: Es existieren Nachweise zu einer positiven Wirkung von aktiven Therapieformen und widersprüchliche Studienergebnisse zu passiven Therapieformen bei muskuloskeletalen Beschwerden. Die Vergleichbarkeit der Studienergebnisse ist aufgrund der unterschiedlichen Darstellung, des umfangreichen Indikationsspektrums und der vorwiegend subjektiven Endpunktmessungen eingeschränkt. Zusatztherapien (wie Medikation und unerwünschte Wirkungen werden vielfach nicht thematisiert.Abgrenzungen zwischen Krankenbehandlung, Kur, Wellness und Setting (ambulant oder stationär sind kaum bis gar nicht möglich.Die Studien zu den verschiedenen Leistungen der physikalischen Medizin zeigen einen einheitlichen Fokus auf (kurzfristige Symptombehandlung und Lebensqualität als Endpunkte. Interessant für ein Gesundheitssystem wäre z.B. der Einfluss physikalischer Behandlungen auf die Mortalität und Morbidität, zum Beispiel im Sinn verhinderbarer Operationen.

  20. Spring Meeting of the German Physical Society : Arbeitskreis FestkÖrperphysik

    CERN Document Server

    the German Physical Society : Arbeitskreis FestkÖrperphysik

    1998-01-01

    This volume contains the invited papers of the Spring meeting of the Arbeitskreis Festkörperphysik of the Deutsche Physikalische Gesellschaft, which has been held in Münster in 1997. The meeting has been attended by roughly 4000 participants from all areas of solid state physics. This book covers the current status of the fileds and shows the excitement which has been felt by the speakers when presenting their results.

  1. Hochempfindliche Oberflächenwellen-Sensoren für die Medizinische Diagnostik

    OpenAIRE

    Rupp, Swen

    2004-01-01

    Kernpunkt dieser Arbeit ist die Entwicklung eines Sensorsystems zur medizinischen Diagnostik von Immunreaktionen. Ein großes Interesse besteht an einer schnellen Detektion von Antigen-Antikörper-Reaktionen. Geringe Stoffkonzentrationen sollen im Bereich von µg/ml in Plasma, Serum oder Blut nachgewiesen werden. Im Rahmen dieser Arbeit wurde ein einfach handhabbares Sensorsystem entwickelt, das für den Einsatz in Arztpraxen und Laboratorien geeignet ist. Als physikalische Grundlage dienen Senso...

  2. International Symposium on Molecular Spectroscopy (70th)

    Science.gov (United States)

    2015-06-22

    Facultad de Ciencias Quı́, Universidad Nacional de Córdoba, Ciudad Universitaria, Córdoba, Argentina. OH···(D2O)N complexes are assembled in He...GABRIEL J. VAZQUEZ, Instituto de Ciencias Fisicas, Universidad Nacional Autonoma de Mexico (UNAM), Cuernavaca, Morelos, Mexico; HANS P. LIEBERMANN...Instituto de Ciencias Fisicas, Universidad Nacional Autonoma de Mexico (UNAM), Cuernavaca, Morelos, Mexico; HANS P. LIEBERMANN, Fachbereich C-Physikalische

  3. FttH-investeringen glashelder beoordelen : kosten model maakt glasvezelaanleg inzichtelijk

    NARCIS (Netherlands)

    Phillipson, F.

    2008-01-01

    Operators en investeerders zijn bijzonder geinteresseerd in de kosten die bij de uitrol van glasvezelnetwerken, zoals Fiber-to-the-Home, komen kijken. Een kostenmodel voor de langetermijnkosten van dergelijke netwerken maakt het mogelijk om diverse technische oplossingen onder verschillende

  4. Reduced enrichment program for the FRM-II, status 2004

    International Nuclear Information System (INIS)

    Roehrmoser, A.; Petry, W.; Boening, K; Wieschalla, N.

    2005-01-01

    The new research reactor FRM-II of the Technische Universitaet Muenchen (TUM) has been designed to provide a maximal thermal neutron flux at mere 20 MW power. The single element design uses silicide fuel of densities 3.0 and 1.5 g/cm 3 of highly enriched uranium (HEU, 93 % U-235). With the nuclear license, that was granted in May 2003, a condition was imposed to reduce the enrichment of FRM-II to medium enriched uranium (MEU) with not more than 50 % U-235 until the end of the year 2010. The TUM has established an international working group to meet this target. This paper presents the backgrounds and the results and plannings for the first of three 2 1/2 year periods to reach the conversion in time. (author)

  5. Integrating Experimentation into Control Courses

    NARCIS (Netherlands)

    Molengraft, van de M.J.G.; Steinbuch, M.; Kraker, de A.

    2005-01-01

    The Department of Mechanical Engineering at the Technische Universiteit Eindhoven, the Netherlands, aims to provide a stimulating educational environment that emphasizes the role of hands-on experiments. To achieve this goal, the Department integrated an experimentation program with courses in the

  6. Haalbaarheidsstudie naar de productie en afzet van Zeeuwse cider

    NARCIS (Netherlands)

    Schreuder, S.A.M.M.; Ravesloot, M.B.M.

    2005-01-01

    Verslag van een onderzoek om inzicht te krijgen in de technische en economische mogelijkheden van de productie van cider in Zeeland. In dat kader is een bureaustudie uitgevoerd naar de kenmerken van de ciderconsumptie en productie in diverse Europese landen.

  7. Voermaatregelen sorteerden geen positief effect bij vleeseenden

    NARCIS (Netherlands)

    Buisonjé, de F.E.; Getkate, J.A.; Enting, H.

    1997-01-01

    In een Spelderholt-proef is gekeken naar mogelijkheden om via voermaatregelen het optreden van pootproblemen bij Peking-eenden te verminderen. Deze maatregelen betroffen de verschijningsvorm, beschikbaarheid en samenstelling van het voer. Tevens is het effect van deze aanpassingen op technische

  8. Optimalisatie performance van vleeskuikens bij mobiel voer- en drinksysteem (scanFeeder) op praktijkbedrijf

    NARCIS (Netherlands)

    Harn, van J.; Veldkamp, T.

    2007-01-01

    Het gebruik van de Ridder ScanFeeder, een mobiel voer- en drinksysteem met strooiselbeluchting voor vleeskuikens, geeft een betere strooiselkwaliteit (ruller en droger strooisel) en minder voetzoolaandoeningen. De technische resultaten bij dit systeem blijven echter achter bij die van een

  9. PAES: Positron annihilation induced Auger electron spectrometer

    OpenAIRE

    Hugenschmidt, Christoph

    2015-01-01

    Positron annihilation induced Auger electron spectroscopy (PAES) is a newly developed application for surface studies with high elemental selectivity and exceptional surface sensitivity. The instrument is operated by the Technische Universität München and is located at NEPOMUC.

  10. Uitdagend en waardevol

    NARCIS (Netherlands)

    Van Hal, J.D.M.

    2008-01-01

    Uitdagend en waardevol Intreerede Uitgesproken op 7 mei 2008 ter gelegenheid van de aanvaarding van het ambt van hoogleraar Sustainable Housing Transformation aan de Faculteit Bouwkunde van de Technische Universiteit Delft door Prof. Dr. Ir. J.D.M. van Hal.

  11. Praktische kengetallen over fokkerij, huisvesting, voeding, lichaamssamensteiling, urine- en fecesproductie en toediening van diergeneesmiddelen bij het varken

    NARCIS (Netherlands)

    Berende, P.L.M.

    1997-01-01

    In dit rapport worden de omstandigheden beschreven waaronder de Nederlandse varkens gehouden worden, alsmede gebruikte rassen en kruisingen. Daarnaast zullen enkele kengetallen m.b.t. de technische resultaten gegeven worden. Verder wordt aandacht besteed aan de lichaamssamenstelling van varkens en

  12. Agro 13 No 3 Ready

    African Journals Online (AJOL)

    Larvicidal Activity of Aqeous Extract of Moringa oleifera Seeds on Anopheles gambiae ... development of resistance mechanisms in the mosquitoes, hence leading to the resurgence of malaria and ..... increasingly regulated world. Annual review of ... Deutsche Gesellschaft fur TechnischeZusammenarbeit (GTZ). Federal ...

  13. Situated cognitive engineering: Developing adaptive track handling support for naval command and control centers

    NARCIS (Netherlands)

    Neerincx, M.A.; Brake, G.M. te; Ven, J.G.M. van de; Arciszewski, H.F.R.; Greef, T.E. de; Lindenberg, J.

    2008-01-01

    Dit artikel presenteert een 'situated cognitive engineering' (SCE) methode voor het verkrijgen van een theoretisch en empirisch onderbouwde Requirements Baseline, waarin operationele, human factors, en technische eisen in samenhang naar voren komen. De methode wordt toegelicht met een ontwerp van

  14. Environmental risk limits for lambda-cyhalothrin

    OpenAIRE

    Leeuwen LC van; Vos JH; Mensink BJWG; SEC

    2008-01-01

    Dit rapport geeft milieurisicogrenzen voor het insecticide lambda-cyhalothrin in water en sediment. Milieurisicogrenzen zijn de technisch-wetenschappelijke advieswaarden voor de uiteindelijke milieukwaliteitsnormen in Nederland. De milieurisicogrenzen zijn afgeleid volgens de methodiek die is voorgeschreven in de Europese Kaderrichtlijn Water.

  15. Technische Documentatie en Handleiding voor MEI 2.0

    NARCIS (Netherlands)

    Oorschot MMP van; Linders D; LAE

    2001-01-01

    The main purpose of this technical documentation is to clearly establish the key ideas and methods used during development of the MEI-model. This document introduces in this way the technical set-up of the model for application developers and administrators. In describing how MEI (version 2) works

  16. Fluid mechanics. An introduction. Technische Stroemungslehre. Eine Einfuehrung

    Energy Technology Data Exchange (ETDEWEB)

    Kalide, W

    1980-01-01

    Originally written for students in the field of engineering, this book may also be of use in the engineering practice. The subject is presented with a view to practice. Fundamental theorems of fluid mechanics are presented without going too much into theory. The chapter on supersonic flow has been extended in the fifth edition as this is a field of great importance in engineering. The new chapter on gas dynamics takes account of these processes in turbine and compressor construction and aeronautical engineering. There is an appendix with material data, characteristic values, flow resistance coefficients, diagrams and two tables with rated pressure loss values for pipeline flow.

  17. PAES: Positron annihilation induced Auger electron spectrometer

    Directory of Open Access Journals (Sweden)

    Christoph Hugenschmidt

    2015-08-01

    Full Text Available Positron annihilation induced Auger electron spectroscopy (PAES is a newly developed application for surface studies with high elemental selectivity and exceptional surface sensitivity. The instrument is operated by the Technische Universität München and is located at NEPOMUC.

  18. Waterverdamping uit dunne mest; resultaten van modelberekeningen

    NARCIS (Netherlands)

    Wagenberg, van A.V.; Verdoes, N.; Vranken, E.; Berckmans, D.

    1999-01-01

    In een geïntegreerd luchtbehandelingsysteem kunnen technische oplossingen voor de emissieproblematiek (ammoniak, geur) en de mestproblematiek worden gecombineerd. Door ventilatielucht uit de stal intensief in contact te brengen met mest kan water uit de mest verdampen. Daardoor droogt de mest. Het

  19. Embedded Linux in het onderwijs

    NARCIS (Netherlands)

    Dr Ruud Ermers

    2008-01-01

    Embedded Linux wordt bij steeds meer grote bedrijven ingevoerd als embedded operating system. Binnen de opleiding Technische Informatica van Fontys Hogeschool ICT is Embedded Linux geïntroduceerd in samenwerking met het lectoraat Architectuur van Embedded Systemen. Embedded Linux is als vakgebied

  20. Experimental Investigation of the Shear Resistance of Steel Frames with Precast Concrete Infill Panels

    NARCIS (Netherlands)

    Hoenderkamp, J.C.D.; Hofmeyer, H.; Snijder, H.H.

    2010-01-01

    At the Technische Universiteit Eindhoven a research program on composite construction is underway aiming at the development of design rules for steel frames with discretely connected precast concrete infill panels subject to in-plane horizontal loading. This paper presents experimental and finite

  1. Spuitbeton op voorgespannen membranen

    NARCIS (Netherlands)

    Pronk, A.D.C.

    2006-01-01

    Op de Technische Universiteit Eindhoven wordt bij de faculteit Bouwkunde onderzoek gedaan naar de mogelijkheden von 'spuitbeton op voorgespannen membranen '. Het onderzoek is onderdeel van een promotietraject. Deze techniek biedt uitkomst voor het maken von vormen die op een andere manier moeiijk

  2. Een biobed, geen praktische oplossing

    NARCIS (Netherlands)

    Sande-Schellekens, van de A.; Backus, G.

    1993-01-01

    De benodigde arbeid voor het laten functioneren van een biobed bedraagt 10 tot 15 minuten per varkensplaats per jaar. Hierbij is geen rekening gehouden met het oplossen van storingen. De biobedden, zoals hier toegepast, zijn door de vele storingen technisch niet inpasbaar

  3. Reale Gase, tiefe Temperaturen

    Science.gov (United States)

    Heintze, Joachim

    Wir werden uns in diesem Kapitel zunächst mit der van der Waals'schen Zustandsgleichung befassen. In dieser Gleichung wird versucht, die Abweichungen, die reale Gase vom Verhalten idealer Gase zeigen, durch physikalisch motivierte Korrekturterme zu berücksichtigen. Es zeigt sich, dass die van derWaals-Gleichung geeignet ist, nicht nur die Gasphase, sondern auch die Phänomene bei der Verflüssigung von Gasen und den kritischen Punkt zu beschreiben.

  4. Entwicklung von Antikörper-Mikroarray : von Biophysik der Mikrospot-Reaktion bis zur Hochdurchsatzanalyse der Proteine

    OpenAIRE

    Kusnezow, Wlad

    2007-01-01

    Obwohl Protein-Mikroarrays ursprünglich aus dem gut entwickelten und fest etablierten DNA-Pendant entstanden sind, repräsentierte jedoch die Umstellung der Mikroarray-Technik von der DNA- auf die Proteinanalyse aufgrund der enormen physikalisch-chemischen Variabilität der Proteine, deren relativ niedrigen Stabilität und der komplexen Mikrospot-Kinetik eine große technologische Herausforderung. Deshalb setzt das Vorhaben, die Technik der Antikörper–Mikroarrays von ihrem konzeptuellen Zustand a...

  5. Struktur-Eigenschaftsbeziehungen in smektischen Flüssigkristallen vom de Vries-Typ

    OpenAIRE

    Nonnenmacher, Dorothee

    2014-01-01

    Ziel dieser Arbeit war es, ein besseres physikalisches Verständnis der Struktur-Eigenschaftsbeziehungen in smektischen Flüssigkristallen vom de Vries-Typ zu erarbeiten und damit eine Basis für rationale Synthesestrategien dieser wissenschaftlich wie technologisch interessanten Materialklasse zu schaffen. Im Sinne dieser Zielvorstellung wurden drei Aspekte bearbeitet: Der Mechanismus der Phasenumwandlung SmA - SmC vom de Vries-Typ, das rationale Design smektischer Flüssigkristalle vom de Vries...

  6. Physikalische Grundlagen von chemischen Raman-Sensoren mit Schwerpunkt auf faseroptischen SERS-Sonden

    OpenAIRE

    Viets, Carmen

    2001-01-01

    Faseroptische SERS-Sensoren wurden durch die Beschichtung der Endflächen von optischen Fasern mit rauhen Metallfilmen erzeugt. Zu den verschiedenen Präparationstechniken, die angewendet und verglichen wurden, gehörten das langsame Aufdampfen von Metall-Inselfilmen und das Bedampfen von Nanopartikeln, aufgerauhten oder elektronenlithographisch strukturierten Oberflächen mit Metallfilmen. Der Einfluß der Laserleistung auf die Messungen mit SERS-Sensoren wurde untersucht, und es wurden maximale ...

  7. EURADOS intercomparison 2012 for neutron dosemeters

    Energy Technology Data Exchange (ETDEWEB)

    Fantuzzi, E. [ENEA-Radiation Protection Institute, Bologna (Italy); Chevallier, M.A. [Institut de Radioprotection et de Surete Nucleaire (IRSN), Fontenay-aux-Roses (France); Cruz-Suarez, R. [International Atomic Energy Agency, Vienna (Austria); Luszik-Bhadra, M. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Mayer, S. [Paul Scherrer Institute (PSI), Villigen (Switzerland); Thomas, D.J. [National Physical Laboratory (NPL), Teddington (United Kingdom); Tanner, R. [Public Health England, Oxon (United Kingdom); Vanhavere, F. [SCK-CEN, Belgian Nuclear Research Centre, Mol (Belgium)

    2014-11-15

    EURADOS, within the work performed by Working Group 2 - Harmonization of Individual Monitoring in Europe, has started a self-sustained programme of regular intercomparisons and has successfully executed three intercomparisons for whole body photon dosemeters (IC2008, IC2010, IC2012) and one intercomparison for extremity dosemeters for photon and beta fields (IC2009). In 2012, the EURADOS intercomparison IC2012n was launched for personal neutron dosemeters routinely used to measure personal dose equivalent, Hp(10), in individual monitoring. No systems under development were allowed to participate. IC2012n was carried out by a EURADOS nominated Organization Group (OG) consisting of: Marie- Anne Chevallier (IRSN, F), Rodolfo Cruz-Suarez (IAEA, UN-Vienna), Marlies Luszik-Bhadra (PTB, D), Sabine Mayer (PSI, CH), David J. Thomas (NPL, UK), Rick Tanner (PHE, UK), Filip Vanhavere (SCK-CEN, B) led by a Coordinator, Elena Fantuzzi (ENEA, I). 31 participants registered for the comparison, with 34 dosimetry systems. In total 816 dosemeters were irradiated in selected neutron fields on an ISO slab phantom. The irradiations were performed at 2 European accredited laboratories which are both National Primary Metrology Laboratories for ionizing radiation: NPL (National Physical Laboratory, UK) and PTB (Physikalisch-Technische Bundesanstalt, D). All irradiations were carried out according to the irradiation plan developed by the OG. The overall results show that most, although not all, dosimetric systems perform acceptably well (within a factor of 2) for irradiations with a bare radionuclide source ({sup 252}Cf at 0 ), whilst more than half of the systems underestimate the reference value for irradiations from non-normal angles of incidence irradiations ({sup 252}Cf at 45 ) or for simulated workplace fields ({sup 252}Cf(D{sub 2}O) or {sup 252}Cf source behind a shadow cone). The performance for 250 keV mono-energetic neutron irradiations varies mainly reflecting the detection

  8. Technische universiteiten en duurzame ontwikkeling in Afrika : Een interfacultair studenten onderzoeksproject voor het 33e lustrumsymposium van de Technische Universiteit Delft

    NARCIS (Netherlands)

    Duijvestein, C.A.J.; de Vries, G.; Bos, M.; Cozijnse, K.; Findlater, J.W.; Fremouw, M.; Jonkman, J.; Oijevaar, K.; Peters, S.; van Rattinghe, K.; Sack-van Straaten, K.; De Vries, G.; Wessels, R.

    2007-01-01

    In 2007, Delft University of Technology celebrates its 165th birthday. This unique occasion is celebrated with several activities revolving around the subject "Sustainable Solutions, with a focus on Africa". For the interdisciplinary course "Technical Universities and Sustainable development of

  9. PROCORAD. An international network for quality control; PROCORAD. Ein internationales Netzwerk zur Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Berard, Philippe [CEA/Direction des Sciences du Vivant, Fontenay-aux-Roses CEDEX (France). Unite PROSITON; Hill, Peter [Forschungszentrum Juelich GmbH (Germany); Kehagia, Konstantina [Greek Atomic Energy Commission, Agia Paraskevi (Greece)

    2011-07-01

    Intercomparisons in the testing field of in-vitro monitoring are an essential tool of quality control. The international network PROCORAD provides its members with annual inter-laboratory comparisons on nine different kinds of samples. They include different matrices (urine, faeces) as well as different radionuclides (e.g. tritium, strontium, polonium, actinides..). In 2010 there were 71 participating laboratories from 21 countries. An annual meeting of the participants offers the opportunity to discuss the results as well as an opportunity to relate to other participants, which is important for both scientific exchange and cross-border emergency response. (orig.)

  10. Applied chemistry and environmental engineering for engineers. Manual for students and practicians. 2. ed.; Angewandte Chemie und Umwelttechnik fuer Ingenieure. Handbuch fuer Studium und betriebliche Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Fessmann, J.; Orth, H.

    2002-07-01

    This is a practically oriented textbook for chemistry and environmental protection training of students of mechanical engineering, vehicle engineering, electrical engineering, space HVAc engineering etc. Students are also given useful information on the practical applications of chemistry and on environmental protection in industrial practice. The book also contains problem solutions for managing engineers in organizations of the metal and electrical branch who are confronted with chemical problems in chemical engineering, quality assurance, industrial safety and environmental protection. [German] Das Handbuch vermittelt in konzentrierter Form die Grundlagen der Chemie und Umwelttechnik und schlaegt rasch die Bruecke zur industriellen Anwendung bevorzugt in der Metall- und Elektroindustrie. Das Handbuch ist ein praxisorientiertes Lehrbuch fuer die Chemie- und Umweltschutzausbildung von Ingenieurstudenten der Fachrichtungen Maschinenbau, Fahrzeugtechnik, Elektrotechnik, Versorgungstechnik u.a. Darueberhinaus finden Schueler von Chemieleistungskursen an Gymnasien oder Chemiestudenten an Fachhochschulen oder Universitaeten viele nuetzliche Informationen ueber die Anwendungen von Chemie und Umweltschutz in der industriellen Praxis. Nicht zuletzt enthaelt das Buch Problemloesungen fuer Betriebsingenieure, insbesondere aus dem Bereich der Metall- und Elektrobranche, die mit chemischen Fragestellungen in der Verfahrenstechnik, Qualitaetssicherung oder Arbeits-/Umweltschutzueberwachung konfrontiert sind. (orig.)

  11. Nikola Tesla: een biografie

    NARCIS (Netherlands)

    ir.ing. Ruud Thelosen

    2015-01-01

    De Technische uitvinder Tesla heeft 700 patenten op zijn naam staan als hij overlijdt. Zijn uitvindingen hebben de wereld in de 20e eeuw volledig veranderd. Zijn wisselstroom generator hebben heel de VS van elektriciteit voorzien. Radioverkeer , remote control werd mogelijk dankzij Tesla. Volgens

  12. 'Uytnemende Schilder van Antwerpen' : Joos van Cleve: atelier, productie en werkmethoden

    NARCIS (Netherlands)

    Leeflang, Micha

    2007-01-01

    Joos van Cleve (ca. 1480-1541) was een van de meest invloedrijke Antwerpse schilders in de eerste helft van dezestiende eeuw. Hij kreeg belangrijke opdrachten voor portretten en altaarstukken van onder anderen de Franse koning Frans I. Micha Leeflang onderzocht met name de materieel-technische

  13. Meer of minder licht

    NARCIS (Netherlands)

    Graaf, A. van der; Steentjes, A.

    2000-01-01

    Interview Wout van Bommel, informatie over DYNO onderzoek van Alferdinck en Hogema bij TNO Technische Menskunde De natuur heeft 'recht op duisternis', zegt de milieubeweging, en daarom moet de verlichting op wegen worden teruggedrongen. De overheid wil dat ook, want de kosten moeten omlaag.

  14. Doorslaan in veld emissie

    NARCIS (Netherlands)

    Abelmann, Leon; le Fèbre, A.J.

    2008-01-01

    Dit verhaal gaat over doorslaan. Het vertelt iets technisch over doorslag in veldemissie, maar vooral hoe een promotie-onderzoek een promovendus tot wanhoop kan drijven, en hoe een begeleider voorkomt dat hij doorslaat. Het begint allemaal bij de hard disk. Dat is een mechanisch geadresseerd

  15. Ethische aspecten van big data

    NARCIS (Netherlands)

    N. (Niek) van Antwerpen; Klaas Jan Mollema

    2017-01-01

    Big data heeft niet alleen geleid tot uitdagende technische vraagstukken, ook gaat het gepaard met allerlei nieuwe ethische en morele kwesties. Om verantwoord met big data om te gaan, moet ook over deze kwesties worden nagedacht. Want slecht datagebruik kan nadelige gevolgen hebben voor

  16. Regional costs and benefits of alternative post-Kyoto climate regimes: Comparison of variants of the Multi-stage and Per Capita Convergence regimes

    NARCIS (Netherlands)

    Vuuren DP van; Elzen MGJ den; Berk MM; Lucas P; Eickhout B; Eerens H; Oostenrijk R; KMD

    2003-01-01

    Deze studie verkent de technische, economische en milieu implicaties van verschillende zogenaamde post-Kyoto regimes voor de verdeling van regionale reductie doelstellingen die leiden tot stabilisatie van de broeikasgasconcentratie in de atmosfeer op 550 en 650 ppmv CO2-equivalenten (het S550e

  17. Reducing Consequences of Car Collision using Inspiration from Nature

    DEFF Research Database (Denmark)

    Lenau, Torben Anker; Helten, Katharina; Hepperle, Clemens

    2011-01-01

    is a result of a project where researchers from two universities (Technical University of Denmark, DTU, and Technische Universität München, TUM) explored three different biomimetic design approaches namely the transfer checklist approach, the inspiration card approach and the interdisciplinary team approach...

  18. Supply chain management in Zuidoost Azië

    NARCIS (Netherlands)

    Wouters, Marc; Wognum, P.M.

    2005-01-01

    Naast veel andere bedrijven uit de Westerse wereld en Japan zijn ook Nederlandse bedrijven actief in opkomende consumentenmarkten in andere delen van de wereld. Zij hebben dan te maken met leveranciers en klanten in die regio's. Studenten Technische Bedrijfskunde van de Universiteit Twente deden

  19. Proceedings of the Eindhoven FASTAR Days 2004 : Eindhoven, The Netherlands, September 3-4, 2004

    NARCIS (Netherlands)

    Cleophas, L.G.W.A.; Watson, B.W.

    2004-01-01

    The Eindhoven FASTAR Days (EFD) 2004 were organized by the Software Construction group of the Department of Mathematics and Computer Science at the Technische Universiteit Eindhoven. On September 3rd and 4th 2004, over thirty participants|hailing from the Czech Republic, Finland, France, The

  20. In Groot-Brittannië heiligt het doel de middelen

    NARCIS (Netherlands)

    Hoof, H.A.J.M. van

    1997-01-01

    In Nederland bestaat nogal wat politieke weerstand tegen observatie met 'technische hulpmiddelen'. In Groot-Brittannië is dat anders. Daar zijn camera's in winkelstraten inmiddels een vertrouwd gezicht geworden. En de Britten gaan nog een stapje verder. Ze hebben sinds kort een database met

  1. The spectral irradiance traceability chain at PTB

    International Nuclear Information System (INIS)

    Sperfeld, P.; Pape, S.; Nevas, S.

    2013-01-01

    Spectral irradiance is a fundamental radiometric unit. Its application to measurement results requires qualified traceability to basic units of the international system of units (Système international d’unités, SI). The Physikalisch-Technische Bundesanstalt (PTB) is amongst other national metrological institutes (NMIs) responsible for the realization, maintenance and dissemination of various radiometric and photometric units based on and traceable to national standards. The unit of spectral irradiance is realized and represented by a blackbody-radiator as the national primary standard of the PTB. Based on Planck’s radiation law, the irradiance is calculated and realized for any wavelength taking into account the exact knowledge of the radiation temperature and the geometrical parameters. Using a double-monochromator-based spectroradiometer system, secondary standard lamps can be calibrated by direct comparison to the blackbody-radiator (substitution method). These secondary standard lamps are then used at the PTB to calibrate standard lamps of customers. The customers themselves use these so-called transfer standards to calibrate their working standard lamps. These working standards are then used to calibrate own spectroradiometers or sources. This rather complex calibration chain is a common procedural method that for the customers generally leads to satisfying measurement results on site. Nevertheless, the standard lamps in use have to fulfill highest requirements concerning stability and reproducibility. Only this allows achieving comparably low transfer measurement uncertainties, which occur at each calibration step. Thus, the PTB is constantly investigating the improvement and further development of transfer standards and measurement methods for various spectral regions. The realization and dissemination of the spectral irradiance using the blackbody-radiator at the PTB is accomplished with worldwide approved minimized measurement uncertainties confirmed

  2. The spectral irradiance traceability chain at PTB

    Energy Technology Data Exchange (ETDEWEB)

    Sperfeld, P.; Pape, S.; Nevas, S. [Physikalisch-Technische Bundesanstalt, Bundesallee 10, 381160 Braunschweig (Germany)

    2013-05-10

    Spectral irradiance is a fundamental radiometric unit. Its application to measurement results requires qualified traceability to basic units of the international system of units (Systeme international d'unites, SI). The Physikalisch-Technische Bundesanstalt (PTB) is amongst other national metrological institutes (NMIs) responsible for the realization, maintenance and dissemination of various radiometric and photometric units based on and traceable to national standards. The unit of spectral irradiance is realized and represented by a blackbody-radiator as the national primary standard of the PTB. Based on Planck's radiation law, the irradiance is calculated and realized for any wavelength taking into account the exact knowledge of the radiation temperature and the geometrical parameters. Using a double-monochromator-based spectroradiometer system, secondary standard lamps can be calibrated by direct comparison to the blackbody-radiator (substitution method). These secondary standard lamps are then used at the PTB to calibrate standard lamps of customers. The customers themselves use these so-called transfer standards to calibrate their working standard lamps. These working standards are then used to calibrate own spectroradiometers or sources. This rather complex calibration chain is a common procedural method that for the customers generally leads to satisfying measurement results on site. Nevertheless, the standard lamps in use have to fulfill highest requirements concerning stability and reproducibility. Only this allows achieving comparably low transfer measurement uncertainties, which occur at each calibration step. Thus, the PTB is constantly investigating the improvement and further development of transfer standards and measurement methods for various spectral regions. The realization and dissemination of the spectral irradiance using the blackbody-radiator at the PTB is accomplished with worldwide approved minimized measurement uncertainties

  3. Optical characterisation of three reference Dobsons in the ATMOZ Project - verification of G. M. B. Dobson's original specifications

    Science.gov (United States)

    Köhler, Ulf; Nevas, Saulius; McConville, Glen; Evans, Robert; Smid, Marek; Stanek, Martin; Redondas, Alberto; Schönenborn, Fritz

    2018-04-01

    Three reference Dobsons (regional standard Dobsons No. 064, Germany and No. 074, Czech Republic as well as the world standard No. 083, USA) were optically characterized at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig in 2015 and at the Czech Metrology Institute (CMI) in Prague in 2016 within the EMRP ENV 059 project Traceability for atmospheric total column ozone. Slit functions and the related parameters of the instruments were measured and compared with G. M. B. Dobson's specifications in his handbook. All Dobsons show a predominantly good match of the slit functions and the peak (centroid) wavelengths with deviations between -0.11 and +0.12 nm and differences of the full width half maximum (FWHM) between 0.13 and 0.37 nm compared to the nominal values at the shorter wavelengths. Slightly larger deviations of the FWHMs from the nominal Dobson data, up to 1.22 nm, can be seen at the longer wavelengths, especially for the slit function of the long D-wavelength. However, differences between the effective absorption coefficients (EACs) for ozone derived using Dobson's nominal values of the optical parameters on one hand and these measured values on the other hand are not too large in the case of both old Bass-Paur (BP) and new IUP-ozone (Institut für Umweltphysik, University of Bremen) absorption cross sections. Their inclusion in the calculation of the total ozone column (TOC) leads to improvements of significantly less than ±1 % at the AD-wavelengths between -1 and -2 % at the CD-wavelengths pairs in the BP-scale. The effect on the TOC in the IUP-scale is somewhat larger at the AD-wavelengths, up to +1 % (D074), and smaller at the CD-wavelengths pair, from -0.44 to -1.5 %. Beside this positive effect gained from the data with higher metrological quality that is needed for trend analyses and satellite validation, it will be also possible to explain uncommon behaviours of field Dobsons during calibration services, especially when a newly

  4. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.

    Science.gov (United States)

    Ebenau, Melanie; Radeck, Désirée; Bambynek, Markus; Sommer, Holger; Flühs, Dirk; Spaan, Bernhard; Eichmann, Marion

    2016-08-01

    Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm(3)) made from the commonly used plastic scintillator BC400. Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a (60)Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks' formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks' formula was determined to be kB = (12.3 ± 0.9) mg MeV(-1) cm(-2). The energy response was quantified relative to the response to (60)Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the

  5. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

    Energy Technology Data Exchange (ETDEWEB)

    Ebenau, Melanie, E-mail: melanie.ebenau@tu-dortmunde.de; Sommer, Holger; Spaan, Bernhard; Eichmann, Marion [Fakultät Physik, Technische Universität Dortmund, Otto-Hahn Str. 4a, 44221 Dortmund (Germany); Radeck, Désirée; Bambynek, Markus [Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig (Germany); Flühs, Dirk [Universitätsklinikum Essen, Hufelandstr. 55, 45147 Essen (Germany)

    2016-08-15

    Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The

  6. PREFACE: PASREG 2003: International Workshop on Processing and Applications of Superconducting (RE)BCO Large Grain Materials

    Science.gov (United States)

    Murakami, Masato; Cardwell, David; Salama, Kamel; Krabbes, Gernot; Habisreuther, Tobias; Gawalek, Wolfgang

    2005-02-01

    Superconducting melt-textured bulk (RE)BCO large grain materials are one of the most promising materials for power applications of high temperature superconductivity at the liquid nitrogen temperature range. Industrial applications are expected in high-speed low-loss magnetic bearings for flywheel energy storage devices, high-dynamic high-torque electric reluctance motors, and MAGLEV transportation systems. The material has high magnetic field trapping capability and therefore a new class of high-field superconducting permanent magnets will soon appear. However, there is still the need to improve the magnetic and mechanical material properties, as well as to increase the single domain size. This special issue contains papers concerning these topics presented at the International Workshop on the Processing and Applications of Superconducting (RE)BCO Large Grain Materials. The workshop was held on the 30 June-2 July 2003 in Jena, Germany, and was organized by the Institut fuer Physikalische Hochtechnologie, Jena. It was the fourth in the series of PASREG workshops after Cambridge, UK (1997), Morioka, Japan (1999), and Seattle, USA (2001). Sixty two contributions were presented at the workshop, 38 oral presentations and 24 poster presentations. This special issue contains 42 papers. The editors are grateful for the support of many colleagues who reviewed the manuscripts to guarantee their high technical quality. The editors also wish to thank Doris Litzkendorf and Tobias Habisreuther from Institut fuer Physikalische Hochtechnologie, Jena, for their assistance with the organization and handling of the manuscripts. Many thanks to the workshop co-chairman Gernot Krabbes from Leibniz-Institut fuer Festkoerper und Werkstoffforschung, Dresden, for hosting the workshop participants in Dresden. Finally, all attendees wish to acknowledge the efforts of Wolfgang Gawalek, Tobias Habisreuther, Doris Litzkendorf and the Team of Department Magnetics from the Institut fuer

  7. Onderzoeksresultaten introductie CNC bij een zestal bedrijven

    NARCIS (Netherlands)

    Mal, van H.H.; Ottink, M.S.; Peters, R.B.

    1987-01-01

    In het kader van een afstudeerproject van de faculteit bedrijfskunde aan de Technische Universiteit Eindhoven is er een onderzoek gedaan naar het gebruik en de gevolgen van het gebruikvan CNC-bewerkings machines in industriële organisaties [1]. Het onderzoek werd uitgevoerd in een zestal bedrijven,

  8. Groener drogen

    NARCIS (Netherlands)

    Loman, N.G.M. (Niek)

    2012-01-01

    Auteur: N.G.M. (Niek) Loman Begeleiders: Ing. H.W. (Pim) van den Dool, Discrete Technologie en Productie Automatisering, RUG Dr.ir. I. (Ingrid) ten Have MBA, Interfac. Opleidingsinst. Technische Bedrijfskunde, RUG Drs. C.M. (Karin) Ree, Bèta Wetenschapswinkel, Science & Society Group, RUG Drs. R.W.

  9. Applying PLM in a formula student racing car design process

    NARCIS (Netherlands)

    Pels, H.J.; van Dongen, P.; Bouras, A.

    2008-01-01

    Field research on PLM application is difficult, because companies don't like scientists to play with their system or with their processes. At Technische Universiteit Eindhoven (TU/e) the University Racing Eindhoven (URE) team decided to use the Siemens PLM Teamcenter license of the university to

  10. Jam Session reloaded: Von der Marmeladenfabrik zum Kultur- und Kreativraum : Revitalisierung und Umnutzung der Zuegg-Marmeladenfabrik am Tribusplatz in Lana, Südtirol

    OpenAIRE

    Hillebrand, Annika

    2015-01-01

    von Annika Hillebrand Zusammenfassung in englischer Sprache Parallelt. [Übers. des Autors]: Jam Session Reloaded: From the jam factory to the cultural and creative space revitalization and redevelopment of Zuegg jam factory on Tribusplatz in Lana, South Tyrol Technische Universität Wien, Univ., Diplomarbeit, 2015

  11. Leben heisst ein Kämpfer sein : zum Verhältnis von Wissenschaft und Öffentlichkeit am Beispiel der modernen Eisenhüttenkunde and der Technischen Hochschule Aachen

    NARCIS (Netherlands)

    Krebs, S.

    2007-01-01

    To Live is to be Fighter - On the Relatioship of Science and Public Illustrated by the Example of Modern Ferrous Metallurgy at the Technical University Aachen. - The contribution pursues the question of how Fritz Wüst, professor of ferrous metallurgy at the Technische Hochschule Aachen (1901-1921),

  12. A borderless Library

    CERN Multimedia

    CERN Library

    2010-01-01

    The CERN Library has a large collection of documents in online or printed format in all disciplines needed by physicists, engineers and technicians. However,  users sometimes need to read documents not available at CERN. But don’t worry! Thanks to its Interlibrary loan and document delivery service, the CERN Library can still help you. Just fill in the online form or email us. We will then locate the document in other institutions and order it for you free of charge. The CERN Library cooperates with the largest libraries in Europe, such as ETH (Eidgenössische Technische Hochschule) in Zurich, TIB (Technische Informationsbibliothek) in Hanover and the British Library in London. Thanks to our network and our expertise in document search, most requests are satisfied in record time: articles are usually served in .pdf version a few hours after the order, and books or other printed materials are delivered within a few days. It is possible to ask for all types of documents suc...

  13. Technically-oriented operation management systems in conjunction with commercial DB systems

    Energy Technology Data Exchange (ETDEWEB)

    Lex, M.; Heselmann, B. [GiS mbH, Erlangen (Germany); Eschbach, P. [BASF Consult GmbH, Muenchen (Germany)

    2001-07-01

    Due to the liberalization of the electricity market, the efficiency and competitiveness of a power plant is increasingly measured at the cost per amount of energy generated. Thus, aspects of market-orientation and clearly cheaper electricity generation are in the foreground. Technically-oriented DP systems are necessary to save operating cost. These systems have structures differing from the mere business-oriented systems, because of the different frame conditions and operators' desire to stand out against rivalling competitors by technical and organizational measures. (orig.) [German] Die Effektivitaet und damit Konkurrenzfaehigkeit eines Kraftwerkes wird mit der Liberalisierung des Strommarktes verstaerkt an den Kosten je erzeugter Energieeinheit gemessen. Fuer den Betrieb ruecken damit Aspekte einer marktgerechten und somit deutlich kostenguenstigeren Stromerzeugung verstaerkt in den Vordergrund. Wer Betriebskosten sparen will, braucht technisch orientierte DV-Systeme, die aufgrund der unterschiedlichen Rahmenbedingungen und des Wunsches aller Anlagenbetreiber, sich durch technisch-organisatorische Massnahmen vom Wettbewerb vorteilhaft abzuheben, voellig andere Strukturen aufweisen als die betriebswirtschaftlich orientierten Systeme. (orig.)

  14. The EPR (European Pressurized Water Reactor) containment - concept, testing of leakage behaviour, FRP liner

    Energy Technology Data Exchange (ETDEWEB)

    Touret, J.P. [EDF SEPTEN, Villeurbanne (France); Liersch, G. [Bayernwerk Kerenergie GmbH, Muenchen (Germany); Danisch, R. [Siemens AG, KWU NAD, Erlangen (Germany)

    2001-07-01

    The Basic Design of the EPR has now been completed. The containment plays a major safety-related role with respect to protection of the environment against radioactive releases. The EPR features a double (steel-reinforced concrete/prestressed concrete) containment design, with the inner containment coated additionally with a fibreglass-reinforced plastic (FRP) liner in certain areas. This means that containment leaktightness is provided mainly by the prestressed concrete and the FRP liner in the event of a postulated accident. The numerous findings of the tests carried out so far in both France and Germany are summarized. (orig.) [German] Das Basic Design fuer den EPR ist fertiggestellt. Entscheidend fuer eine Realisierung wird neben der politischen Akzeptanz vor allem die Wettbewerbsfaehigkeit mit anderen Energietraegern sein. Im EPR-Projekt wird der hohe Sicherheitsstandard der heutigen Kernkraftwerke in Deutschland und Frankreich ergaenzt, indem zusaetzlich technische Massnahmen ergriffen werden, um die Konsequenzen beim unterstellten Versagen aller sicherheitstechnischen Einrichtungen mit der Folge eines postulierten Niederschmelzen des Kerns technisch zu beherrschen. (orig.)

  15. (Distributed) Denial-of-Service : deel 2

    NARCIS (Netherlands)

    Luiijf, H.A.M.

    2013-01-01

    Het geblokkeerd raken van een dienstverlening wordt in het Engels vaak aangeduid met de term Denial-of-Service (afkort: DoS). Al wordt de term veelal gebruikt in de cyberspace-omgeving, is deze feitelijk generieker, DoS kan zowel een technische oorzaak hebben, als bewust worden veroorzaakt door

  16. Communicatie-architectuur PLC’s en Unity

    NARCIS (Netherlands)

    J.L. Scholte

    2017-01-01

    Voor het afronden van de studie Technische Informatica aan de Haagse Hogeschool te Delft is het noodzakelijk om een afstudeeropdracht uit te voeren. In de loop van zeventien weken is deze opdracht uitgevoerd bij het bedrijf JB Systems te Vlaardingen en Delft door de afstudeerder Jordy Scholte. Dit

  17. The physics of big sample instrumental neutron activation analysis

    NARCIS (Netherlands)

    Overwater, R.M.W.

    1994-01-01

    Proefschrift ter verkrijging van de graad van doctor aan de Technische Universiteit Delft, op gezag van de Rector Magnificus Prof.ir. K.F. Wakker, in het openbaar te verdedigen ten overstaan van een commissie, door het College van Dekanen aangewezen, op maandag 14 november 1994 te 16.00 uur.

  18. Physik gestern und heute: Visualisierung mit der Schlierenmethode

    Science.gov (United States)

    Heering, Peter

    2006-07-01

    Der Name des österreichischen Forschers Ernst Mach ist heute noch mit der Schallgeschwindigkeit verbunden. Diese Auszeichnung resultiert aus Machs Untersuchungen, wie sich Projektile mit Überschallgeschwindigkeit durch die Luft bewegen. Gerade in jüngster Zeit hat die Anwendung derartiger Methoden durch technische Modifikationen wieder einen Aufschwung erfahren.

  19. Privacy, werk en internet of things

    NARCIS (Netherlands)

    Van Der Sype, Yung Shin; Vedder, Anton

    2016-01-01

    Technologisch zijn ondernemingen nog niet klaar voor 3.0. Hoewel reeds heel wat technische snufjes in de onderneming binnensijpelen, staat de technologie nog niet op punt om al van een Internet of Things te spreken. Dit geeft ons de tijd om ons juridisch voor te bereiden op de opkomende

  20. Tax accounting - IFRS IAS 12 : Voor accountants, controllers en fiscalisten

    NARCIS (Netherlands)

    Naarding, E.; Langendijk, H.P.A.J.

    2010-01-01

    Deel 7 van de reeks 'Tax Assurance in beeld' is een werkboek dat vraagstukken bevat om de technische aspecten van IAS 12 Income Taxes van de International Accounting Standards Board (IASB) te oefenen. Het boek is bedoeld voor accountants, controllers en fiscalisten die zich willen bekwamen in de

  1. Tax accounting - IFRS IAS 12: Voor accountants, controllers en fiscalisten

    NARCIS (Netherlands)

    Naarding, E.W.J.; Langendijk, H.P.A.J.

    2010-01-01

    Deel 7 van de reeks 'Tax Assurance in beeld' is een werkboek dat vraagstukken bevat om de technische aspecten van IAS 12 Income Taxes van de International Accounting Standards Board (IASB) te oefenen. Het boek is bedoeld voor accountants, controllers en fiscalisten die zich willen bekwamen in de

  2. Bio-coke as an alternative to petroleum coke and metallurgical coke; Bio-cokes als alternatief voor petroleumcokes en metallurgische cokes

    Energy Technology Data Exchange (ETDEWEB)

    Croezen, H.J.; Van Lieshout, M. [CE Delft, Delft (Netherlands); Sevenster, M.N. [Sevenster Environmental Consultancy, Australian Capital Territory ACT (Australia)

    2012-11-15

    In the framework of elaborating the Dutch Roadmap Chemistry 2030), CE Delft has conducted an exploratory study for the Association of the Dutch Chemical Industry (VNCI) on the options of replacing (petroleum) coke in the chemical sector by biocokes. Coke is used as a reducing agent and/or raw material in four companies in the Dutch chemical industry (Tronox, ESD-SIC, Thermphos, Aluchemie). Replacing coke at these four companies can potentially yield a direct CO2 reduction of expectedly several hundreds of kilotons per year. For a first exploration of the options of bio-coke, CE Delft first conducted a desk study to get information on the quality and production costs for bio-coke. Subsequently, CE Delft had contact with the four chemical companies and a made a number of company visits. Moreover, the technical, economic and organizational capabilities, constraints and requirements with regard to a possible (partial) switch to biocokes have been explored. Based on the information available so far it can be concluded that biocokes seems to be a technically and economically interesting innovation. For implementation to finally take place, it is necessary to gain better insight in the technical and economic potential [Dutch] In verband met de uitwerking van de Routekaart Chemie 2030 heeft CE Delft voor VNCI een verkenning uitgevoerd naar de mogelijkheden voor vervanging van (petroleum)cokes in de chemische sector door biocokes. Cokes wordt gebruikt als reductiemiddel en/of grondstof bij een viertal bedrijven in de Nederlandse chemie (Tronox, ESD-SIC, Thermphos, Aluchemie). Het vervangen van cokes bij deze vier bedrijven kan in potentie een directe CO2-reductie van naar verwachting enkele honderden kilotonnen/jaar opleveren. Voor een eerste verkenning van de mogelijkheden van bio-cokes heeft CE Delft eerst een bureaustudie uitgevoerd naar informatie over kwaliteit van en productiekosten voor bio-cokes. Vervolgens heeft CE Delft contact gehad met de vier chemische

  3. Persistent chlorinated hydrocarbons (PHC) - end products and intermediate products of technical synthesis processes in surface water of the Rhine region. Vol. 5: Site profiles of persistent chlorinated hydrocarbons - source-oriented monitoring in aquatic media; Persistente chlorierte Kohlenwasserstoffe (PCKW) - End- und Zwischenprodukte technischer Synthesen in Gewaessern der Rheinregion. Band 5 der Reihe: Standortprofile persistenter chlorierter Kohlenwasserstoffe - ursachenorientiertes Monitoring in aquatischen Medien

    Energy Technology Data Exchange (ETDEWEB)

    Heinisch, E.; Kettrup, A.; Bergheim, W.; Wenzel, S.

    2003-07-01

    Schwebstoffen, die in 20 zumeist Landesinstitutionen z. T. im Zeitraum von 1984-2002 erhoben worden waren, wurde der Versuch unternommen, die Belastungshoehen und Stoffmusterprofile fuer Probenahmelokalitaeten am Rhein und Fluessen in BW, Hess, RP und NRW kenntlich zu machen. Die untersuchten Verbindungen waren die isomeren Di-, Tri- und Tetrachlorbenzene, Penta- und Hexachlorbenzen, Ochtachlorstyren (OCS), Hexachlorbutadien (HCBD) sowie die 6 DIN-(IUPAC-, Ballschmiter)Kongenere der PCB, Substanzen, die zumeist im Sinne von REACH als PBT-, z. T. als vPvB-Stoffe bezeichnet wurden bzw. als ''prioritaer gefaehrliche Stoffe'' (PCBz, HCB, HCBD) eingestuft sind. Die statistisch verrechneten Einzeldaten wurden zu Streckenprofilen und Zeitreihen verarbeitet, mit dem Ziel, lokale oder regionale Immissionen, Hinweise zu ihrer Entstehung und gegenwaertigen Bedeutung kenntlich zu machen. Hintergrund dieser Bestrebungen ist, dass Fachpublikationen ueber technische Synthesen oder Zwangsanfall der Verbindungen nach Art, Menge und Zeitraum nicht vorliegen, was als Defizit zu betrachten ist. Besonders Tetrachlorbenzen (hauptsaechlich das 1,2,4,5-TeCBz) und das HCBD konnten als Indikatorsubstanzen fuer historische und rezente technische Synthesen chlororganischer Verbindungen sichtbar gemacht werden. Die hoeher chlorierten PCB-Kongenere Nr. 138, 153 und 180 (HPCB) erwiesen sich als ausserordentlich persistent. Die Chemiestandorte im Umfeld der Probenahmelokalitaeten Rheinfelden, Grenzach, Lampertheimer Altrhein, Biebesheimer Rhein, Muendung Schwarzbach, Bischofsheim und Griesheim (Main), Hitdorf, Duisburg-Homberg und Huels (Lippe) konnten durch Maxima und spezielle Stoffmusterverteilungen transparent gemacht werden. (orig.)

  4. The calibration of the solid state nuclear track detector LR 115 for radon measurements

    CERN Document Server

    Gericke, C; Jönsson, G; Freyer, K; Treutler, H C; Enge, W

    1999-01-01

    An experimental calibration of indoor room and outdoor soil detector devices which are based on LR 115 as sensitive element has taken place at the Swedish Radiation Protection Institute in Stockholm (Sweden) in 1994 and 1996, at the Physikalisch-Technischen Bundesanstalt in Braunschweig (Germany) in 1997 and at the Umweltforschungszentrum Leipzig-Halle (Germany) in 1997. Special properties of the used solid state nuclear track detector (SSNTD) material LR 115 have been measured to define the application of the experimental calibration.

  5. 12th February - Lower Saxony Minister for Science and Culture L. Stratmann MP signing the guest book with CERN Director-General R. Heuer.

    CERN Multimedia

    Michel Blanc

    2010-01-01

    other Members of the delegation: State of Lower Saxony, Ministry of Science and Culture,Head of Science and Innovation H. Gevers ATLAS Collaboration and II. Physikalisches Institut, Georg-August-Universität Göttingen A. Quadt Accompanied by CERN Adviser to the Coordinator for External Relations R. Voss Visiting the Antiproton Decelerator Facility with AEGIS Collaboration Spokesperson M. Doser, the Superconducting Magnet Test Hall with Technology Departement R. Schmidt and ATLAS visitor centre with Former Collaboration Spokesperson P. Jenni and T. Wengler.

  6. Intelligent networks and energy storage; Intelligente netten en energieopslag

    Energy Technology Data Exchange (ETDEWEB)

    Ongkiehong, O.; Van den Berg, P.

    2012-11-15

    The emergence of decentralized generators cause electricity networks to become more complex and technically difficult to control. This article highlights the role of ICT [Dutch] Door de opkomst van decentrale opwekkers worden elektriciteitsnetten steeds complexer en moeilijker om technisch te beheersen. In dit artikel wordt de rol van ICT belicht.

  7. Jeewanu, or the

    Indian Academy of Sciences (India)

    2011-08-16

    Aug 16, 2011 ... Author Affiliations. Mathias Grote1 2. Egenis, University of Exeter, Byrne House, St. German's Road, Exeter EX4 4PJ, UK; Institut für Philosophie, Literatur, Wissenschafts- und Technikgeschichte, Technische Universität Berlin, Straße des 17.Juni 135, D-10623 Berlin, Germany ...

  8. Meer proeven nodig om effect van hogere F-scatterwaarde te achterhalen : diffuus glas komt in de fase van fine-tuning (interview met Silke Hemming en Tom Dueck)

    NARCIS (Netherlands)

    Kierkels, T.; Hemming, S.; Dueck, T.A.

    2014-01-01

    Diffuus glas is over vijftien jaar de standaard. Wie nu nieuw bouwt, heeft veel goede redenen om voor diffuus te kiezen en vrijwel geen om het te laten, zeggen Silke Hemming en Tom Dueck van Wageningen UR Glastuinbouw. De inzichten in het nut van diffuus licht én de technische ontwikkelingen

  9. J.A. van der Kloes (1845-1935) : A professional biography of the first Dutch professor in building materials

    NARCIS (Netherlands)

    Quist, W.J.

    2015-01-01

    Prof. Jacobus Alida van der Kloes (1845-1935) was appointed teacher in building materials at the “Polytechnische school” of Delft in 1882. From 1905 until his retirement in 1915 he was promoted to full professor on the subject of knowledge and research of building materials at the “Technische

  10. Le fabbriche del cioccolato : settore e impresa in Germania, Svizzera e Italia tra il tardo '800 e la Prima Guerra Mondiale

    OpenAIRE

    CHIAPPARINO, Francesco

    1995-01-01

    Defence date: 28 April 1995 Examining Board: Prof. Albert Carreras (Universitat Pompeu Fabra, Barcelona, supervisore) ; Prof. Peter Hertner (IUE, supervisore esterno) ; Prof. René Leboutte (IUE) ; Prof. Ulrich Wengenroth (Technische Universität, München) ; Prof.ssa Vera Zamagni (Università di Bologna) First made available online: 30 August 2016

  11. Chemical purification of CaCO{sub 3} and CaWO{sub 4} powders used for CaWO{sub 4} crystal production for the CRESST experiment

    Energy Technology Data Exchange (ETDEWEB)

    Trinh Thi, H.H.; Defay, X.; Erb, A.; Hampf, R.; Lanfranchi, J.C.; Langenkaemper, A.; Morgalyuk, V.; Muenster, A.; Mondragon, E.; Oppenheimer, C.; Potzel, W.; Schoenert, S.; Steiger, H.; Ulrich, A.; Wawoczny, S.; Willers, M.; Zoeller, A. [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen, Garching (Germany)

    2016-07-01

    CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) uses CaWO{sub 4} single crystals as targets for the direct search for dark matter particles. Since several years these CaWO{sub 4} crystals are grown at the Technische Universitaet Muenchen. Thereby, commercially available CaCO{sub 3} and WO{sub 3} powders are used for the synthesis of CaWO{sub 4} powder. For the experiment low intrinsic contaminations of the crystals play a crucial role. In order to improve the radiopurity of the crystals it is necessary to reduce potential sources for radioactive backgrounds such as U and Th. In this poster we will present our studies of the chemical purification of the CaCO{sub 3} and CaWO{sub 4} powders.

  12. The neutron lifetime experiment PENeLOPE

    Energy Technology Data Exchange (ETDEWEB)

    Schreyer, Wolfgang [Technische Universitaet Muenchen (Germany); Collaboration: PENeLOPE-Collaboration

    2015-07-01

    The neutron lifetime τ{sub n}=880.3±1.1 s is an important parameter in the Standard Model of particle physics and in Big Bang cosmology. Several systematic corrections of previously published results reduced the PDG world average by several σ in the last years and call for a new experiment with complementary systematics. The experiment PENeLOPE, currently under construction at the Physik-Department of Technische Universitaet Muenchen, aims to determine the neutron lifetime with a precision of 0.1 s. It will trap ultra-cold neutrons in a magneto-gravitational trap using a large superconducting magnet and will measure their lifetime by both neutron counting and online proton detection. This presentation gives an overview over the latest developments of the experiment.

  13. Advances in Solid State Physics

    CERN Document Server

    Haug, Rolf

    2008-01-01

    The present volume 47 of the Advances in Solid State Physics contains the written version of a large number of the invited talks of the 2007 Spring Meeting of the Arbeitskreis Festkörperphysik which was held in Regensburg, Germany, from March 26 to 30, 2007 in conjunction with the 71st Annual Meeting of the Deutsche Physikalische Gesellschaft.It gives an overview of the present status of solid state physics where low-dimensional systems such as quantum dots and quantum wires are dominating. The importance of magnetic materials is reflected by the large number of contributions in the part dealing with ferromagnetic films and particles. One of the most exciting achievements of the last couple of years is the successful application of electrical contacts to and the investigation of single layers of graphene. This exciting physics is covered in Part IV of this book. Terahertz physics is another rapidly moving field which is presented here by five contributions. Achievements in solid state physics are only rarely...

  14. Lung cancer - hopelessness when inoperability? The 10-year follow-up study; Lungenkrebs - Hoffnungslosigkeit bei Inoperabilitaet? 10 Jahre danach

    Energy Technology Data Exchange (ETDEWEB)

    Schwegler, N. [Kantonsspital Aarau (Switzerland). Abt. fuer Strahlentherapie

    1997-07-01

    Background: According to reports of Durrant et al. [19] and Berry et al. [5] it was concluded that non-operable non-small cell lung tumors cannot be cured. In this consequence initiation of radiotherapy was fixed at the beginning of symptoms. However, long-time survivors in our follow-up lead us to analyse not only quality of life and secondary therapeutic effects but also this special group with the results of the whole collective treated in the same period of interest. Results: From 145 patients with non-small cell lung cancer 64.1% (93/145) survived 6 months, 42.8% (62/145) 1 year, 19.3% (28/145) 2 years and 7.6% (11/145) 5 and 4.8 (7/145) more than 10 years. According to TN-stages T1-4 N0 collective had a survival rate of 67.8% (40/59) after half a year, 50.8% (30/59) after 1 year, 23.7% (14/59) after 2 and 11.9% (7/59) after 5 years. Treatment results by patients with positive lymph nodes T1-4 N1-3 after the same intervals are: 61.6% (53/86), 37.2% (32/86), 16.2% (14/86) respectively 4.7% (4/86). In the period 5 to 10 years after irradiation 4 patients died, 1 with local relapse, 2 with contralateral lung cancer - ipsilateral region was endoscopically and histologically free of tumor - and 1 patient in consequence of heart insufficency of several years. Seven patients are still alive after 13 to 16 years. There is no sign of tumor in this group or any effects limitating their quality of life. Twenty-four patients received less than 50 Gy. All patients but 2 did not survive 6 months. One patient survived half a year and 1 patient 2 years. (orig./AJ) [Deutsch] Hintergrund: Nach Publikationen von Durrant et al. [19] und Berry et al. [5] im Laufe der siebziger Jahre machte sich beim inoperablen Bronchuskarzinom in manchen onkologischen Zentren ein therapeutischer Nihilismus breit. Diesem damaligen Trend hatten wir uns trotz begrenzter technischer Mittel nicht angeschlossen. Begegnungen im Rahmen der Nachsorge mit Langzeitueberlebenden nach lokal

  15. Anordnung fuer die optische Ueberwachung und/oder Bestimmung physikalischer und/oder chemischer Messgroessen

    OpenAIRE

    Wilhelmi, B.; Schreiber, J.; Nebel, D.

    2007-01-01

    WO 2009068023 A2 UPAB: 20090629 NOVELTY - The assembly giving an optical monitoring and/or measurement of physical and/or chemical has an optic fiber (1) to carry electromagnetic radiation to an optical detector. The fiber has a sensitive zone, where the fiber material is replaced by a material or mixture, which is optically transparent in the radiation wavelength. The replacement material has the same refractive index as the fiber or the refractive index deviation is less than difference bet...

  16. 44. Annual Convention of the Austrian Physical Society; Oesterreichische Physikalische Gesellschaft - 44. Jahrestagung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    There are about 270 contributions presented by title and abstract only. 250 of them are of INIS interest. The range of subject matters covered is indicated by the headings of topical sessions: (1) acoustics (2) atomic-, molecular- and plasma physics (3) solid-state physics (4) nuclear- and particle physics (5) school teachers` continuing education (6) medical-, bio-and environmental physics (7) polymer physics (8) quantum electronics, electrodynamics and optics. (blahsl).

  17. Chemical and physical properties of gas hydrates; Chemische und physikalische Eigenschaften von Gashydraten

    Energy Technology Data Exchange (ETDEWEB)

    Meyn, V. [Inst. fuer Erdoel- und Erdgasforschung, Clausthal-Zellerfeld (Germany)

    1997-12-31

    Numerous properties of gas hydrates can be inferred directly from their phase behaviour. The present contribution gives a short overview of the properties of gas hydrates using pressure-temperature curves to depict their phase behaviour. It also describes the growth kinetics and inhibition of gas hydrates. (MSK) [Deutsch] Eine Vielzahl der Eigenschaften von Gashydraten lassen sich direkt aus ihrem Phasenverhalten herleiten. In kurzer Form wird ein Ueberblick ueber die Eigenschaften der Gashydrate gegeben. Druck-Temperatur-Diagramme erlaeutern des Phasenverhalten. Ebenso wird die Wachstumskinetik und die Inhibierung der Gashydrate beschrieben.

  18. Technische Feuchtgebiete zur Nachreinigung von Abwasser:Stickstoff, Abwasserdesinfektion, Spurenstoffe

    OpenAIRE

    Rühmland, Sabine

    2015-01-01

    Stickstoff, Spurenstoffe und Krankheitserreger können auch in geringen Mengen Schäden in Gewässern bzw. beim Menschen verursachen. In dieser Arbeit soll geklärt werden, inwieweit das naturnahe Abwasserreinigungsverfahren der technischen Feuchtgebiete zur Nachreinigung von Abwasser geeignet ist. Dafür wurden in Berlin sieben bewachsene Bodenfilter und Abwasserteiche im techni-schen Maßstab einer Kläranlage mit Nährstoffelimination nachgeschaltet. Ein Sandfilter, ein Sandfilter mit Lehm und...

  19. Technical progress safeguards future. Technischer Fortschritt sichert die Zukunft

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    'Technical progress safeguards future', the guiding theme of the 1985 conference of German engineers, calls for discussion. In five lectures representatives of the subdivisions of 'VDI' issued their statements from the viewpoints of their special fields. These lectures were completed by reports on the part of the remaining VDI subdivisions, which are published together with the lectures in this volume. The complex guiding theme is meant to stimulate discussion, which should be conducted also with representatives of other sciences and the public. The volume contains a.o. contributions regarding future prospects, given certain modifications in construction engineering and user behaviour in the sector heating and air-conditioning, regarding the development of new construction techniques to protect the environment, and regarding clean air as an international concern of engineers. For these three contributions separate entries were made. Other presentations relate to: automobile production technology; energy supply as an engineering task; information, invention, innovation as stages of technical progress; progress in materials technology; noise of motor vehicles - current state and future prospects. (orig./HSCH).

  20. A new genus and species of deep-sea glass sponge (Porifera, Hexactinellida, Aulocalycidae) from the Indian Ocean

    Digital Repository Service at National Institute of Oceanography (India)

    Sautya, S.; Tabachnick, K.R.; Ingole, B.S.

    –XXVI. Schulze FE (1886) Über den Bau und das System der Hexactinelliden. Abhandlungen der Königlichen Akademie der Wissenschaften zu Berlin (Physikalisch-Mathematisch Classe) 1886: 1–97. Schmidt O (1880) Die Spongien des Meerbusen von Mexico (Und des... of Mexico, by the USCSS ‘Blake’. Gustav Fischer, Jena, 33–90, pls V-X. A new genus and species of deep-sea glass sponge... 21 Mehl D (1992) Die Entwicklung der Hexactinellida seit dem Mesozoikum. Paläobiologie, Phylogenie und Evolutionsökologie. Berliner...

  1. Annual report 1978. [Natural gas

    Energy Technology Data Exchange (ETDEWEB)

    1979-05-01

    In the 1978 annual reports of the Deutscher Verein des Gas- und Wasserfaches (DVGW), the Bundesverband der deutschen Gas- und Wasserwirtschaft (BGW), and the Technische Vereinigung der Firmen im Gas- und Wasserfach e.V. (FIGAWA), the activities of organisations and Laender groups are dealt with, as well as tasks, work, and sales promotion measures.

  2. 3. European conference of TRIGA users. Papers and abstracts

    International Nuclear Information System (INIS)

    1974-01-01

    The Third European Conference of TRIGA Users was held October 29-31, 1974, in Neuherberg near Munich, Germany under the sponsorship of the Gesellschaft fur Strahlen and Umweltforschung mbH, Physikalischen-Technische Ableilung. The main topics were: experience in reactor operation, maintenance, measurements, fuel management and fuel performance, neutron physical experiments and other research programs

  3. Innovations and airborne pollutants. An economic assessment of the influence of different boundary conditions with explicit modelling of the choice of technology in the industrial sector. Interim report - documentation for the steel industry; Innovationen und Luftschadstoffemissionen. Eine gesamtwirtschaftliche Abschaetzung des Einflusses unterschiedlicher Rahmenbedingungen bei expliziter Modellierung der Technologiewahl im Industriesektor. Zwischenbericht - Dokumentation Stahlindustrie

    Energy Technology Data Exchange (ETDEWEB)

    Schleich, J.; Nathani, C.; Ostertag, K.; Schoen, M.; Walz, R.; Meyer, B.; Lutz, C.; Distelkamp, M.; Wolter, M.I.; Hohmann, F.

    2002-04-01

    The project attempted an improved modelling of technological progress. For this, the basic technological processes of selected energy-intensive sectors of the econometric input-output model PANTA RHEI are mapped in a model-consistent systematics. Technological progress is assumed to derive from the modelled decision making behaviour during selection of a technology. Apart from an improved assessment of the economic and environmental effects of political decisions, also the innovation effects are modelled. Further, politically induced technological progress is reduced explicitly to technologies. [German] Ziel des Projekts ist eine methodisch verbesserte Modellierung des technischen Fortschritts. Dazu werden fuer ausgewaehlte energieintensive Branchen des oekonometrischen Input-Output Modells PANTA RHEI die zugrunde liegenden technologischen Prozesse in einer modellkonsistenten Systematik abgebildet. Ein weiteres innovatives Element besteht darin, dass technischer Fortschritt auf das modellierte Entscheidungsverhalten bei der Technikwahl zurueckgefuehrt werden kann. Die gewaehlte Modellierung erlaubt nicht nur eine verbesserte Abschaetzung der durch Politikmassnahmen ausgeloesten gesamtwirtschaftlichen und der umweltrelevanten Wirkungen, sondern auch eine Bewertung der Innovationseffekte. Ausserdem laesst sich politik-induzierter, technischer Fortschritt explizit auf Technologien zurueckfuehren. (orig.)

  4. FRM-II: status of construction, licensing fuel tests

    International Nuclear Information System (INIS)

    Axmann, A.; Boening, K.; Nuding, M.; Didier, H.J.

    2001-01-01

    The research reactor FRM-II of the Technische Universitaet Muenchen is now ready for the nuclear start-up, but still waiting for the operational license. The high-flux neutron-source FRM-II (8 x 10 14 n/(s cm 2 ) is a unique tool for solid state physics and materials research by neutron scattering, positron annihilation experiments and activation analysis, as well as for fundamental physics, isotope production, silicone doping, cancer therapy by irradiation with fission neutrons and for tomography with fast and thermal neutrons. Reactor built in facilities as a hot source, a cold source, an uranium loaded converter plate producing an intense beam of fission neutrons, allow to expand the range of usable neutron energies far beyond the thermal spectrum. In addition, a source providing an intense beam of fission products is planned to be constructed by the Ludwig-Maximilians-Universitaet Muenchen and a source of ultra cold neutrons is planned by the Physics Department of the Technische Universitaet Muenchen. The reactor is already prepared for both of these facilities. (author)

  5. Development and evaluation of a meteorological model system for assessing the effect of environmental measures on climate and air quality. Vol. 2: Appendices 6 through 10; Entwicklung und Evaluierung eines meteorologischen Modellsystems zur Folgenabschaetzung von Umwelteingriffen auf Klima und Luftqualitaet. Bd. 2: Anhaenge 6-10

    Energy Technology Data Exchange (ETDEWEB)

    Bigalke, K. [Hamburg Univ. (Germany). Meteorologisches Inst.; Schluenzen, K.H. [METCON Umweltmeteorologische Beratung, Pinneberg (Germany)

    2001-09-01

    The project focused on the development of a low-cost planning tool for authorities and consulting engineers which meets the envisaged national quality standards (VDI standards). The program system METRAS{sup +} consists of four components for preparation, implementation and quality assurance of mesoscale model calculations, all under Windows. The program system will not be commercialized; instead, it will be made available to interested users at a small fee by the Meteorological Institute of Hamburg University. [German] Ziel war die Bereitstellung eines kostenguenstigen Planungsinstrumentes fuer Behoerden und Beratungsunternehmen, das geplante nationale Qualitaetsnormen (VDI-Richtlinie) erfuellt. Vergleichbare Modelle existieren bislang nur im wissenschaftlichen Bereich, sind kaum qualitaetsgesichert und werden u.a. aus wirtschaftlichen Erwaegungen nur in Ausnahmefaellen eingesetzt. Das Programmsystem METRAS{sup +} setzt sich aus vier Programmkomponenten zusammen, die der Vorbereitung, Durchfuehrung und Qualitaetssicherung mesoskaliger Modellrechnungen dienen. Alle Programmkomponenten laufen unter einer gemeinsamen, anwenderfreundlichen Windowsoberflaeche. Um die breite Anwendung qualifizierter Untersuchungsmethoden im Umweltconsulting zu foerdern, ist geplant, METRAS{sup +} nicht kommerziell zu vertreiben und das Programmsystem interessierten Anwendern gegen einen geringen Kostenbeitrag zur Verfuegung zu stellen. Vertrieb und Oeffentlichkeitsarbeit sollen vom Meteorologischen Institut der Universitaet Hamburg geleistet werden. (orig.)

  6. Development and evaluation of a meteorological model system for assessing the effect of environmental measures on climate and air quality. Vol. 1: Main part and appendices 1 through 5. Final report; Entwicklung und Evaluierung eines meteorologischen Modellsystems zur Folgenabschaetzung von Umwelteingriffen auf Klima und Luftqualitaet. Bd. 1: Hauptteil und Anhaenge 1 bis 5. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Bigalke, K. [METCON Umweltmeteorologische Beratung, Pinneberg (Germany); Schluenzen, K.H. [Hamburg Univ. (Germany). Meteorologisches Inst.

    2001-09-01

    The project focused on the development of a low-cost planning tool for authorities and consulting engineers which meets the envisaged national quality standards (VDI standards). The program system METRAS{sup +} consists of four components for preparation, implementation and quality assurance of mesoscale model calculations, all under Windows. The program system will not be commercialized; instead, it will be made available to interested users at a small fee by the Meteorological Institute of Hamburg University. [German] Ziel war die Bereitstellung eines kostenguenstigen Planungsinstrumentes fuer Behoerden und Beratungsunternehmen, das geplante nationale Qualitaetsnormen (VDI-Richtlinie) erfuellt. Vergleichbare Modelle existieren bislang nur im wissenschaftlichen Bereich, sind kaum qualitaetsgesichert und werden u.a. aus wirtschaftlichen Erwaegungen nur in Ausnahmefaellen eingesetzt. Das Programmsystem METRAS{sup +} setzt sich aus vier Programmkomponenten zusammen, die der Vorbereitung, Durchfuehrung und Qualitaetssicherung mesoskaliger Modellrechnungen dienen. Alle Programmkomponenten laufen unter einer gemeinsamen, anwenderfreundlichen Windowsoberflaeche. Um die breite Anwendung qualifizierter Untersuchungsmethoden im Umweltconsulting zu foerdern, ist geplant, METRAS{sup +} nicht kommerziell zu vertreiben und das Programmsystem interessierten Anwendern gegen einen geringen Kostenbeitrag zur Verfuegung zu stellen. Vertrieb und Oeffentlichkeitsarbeit sollen vom Meteorologischen Institut der Universitaet Hamburg geleistet werden. (orig.)

  7. Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, D [KEMA-IEV GmbH, Dresden (Germany); Brossmann, E; Wetzel, H [VEAG Berlin (Germany)

    1997-12-01

    The geothermal heat exchanger transfers heat geothermal heat through the metal wall of the outer pipe to the circulating water. The clean water heats up on its way down and is then pumped up again through the insulated inner riser pipe. The heated water is used for district heating. Drilling started on 26 March 1994, and the system was commissioned on 10 November 1994. Today, it supplies heat and warm water to about 1100 apartments. During its first year of operation the Prenzlau geothermal heat exchanger, which is 2800 m deep, covered more than 20 % of the heat demand of the Prenzlau-West district heating grid. The seasonal performance factor in continuous operation of the 500 kW system is between 8 and 12 % of the weather-dependent peak load, with hourly peaks of more than 700 kW. (orig./AKF) [Deutsch] Die Erdwaermetiefensonde nutzt die Waermeuebertragung vom warmen Erdreich durch die Metallwand des Aussenrohrs zum darin zirkulierenden Wasser. Das eingeleitete saubere Wasser erwaermt sich an der aeusseren Rohrwandung auf dem Weg nach unten und wird dann im inneren waermeisolierten Steigrohr an die Oberflaeche befoerdert. Das erwaermte Waser wird in Prenzlau ueber eine Waermepumpe zu Fernwaermezwecken benutzt. Am 26.3.1994 begannen die Bohrarbeiten, und am 10.11.1994 ging die gesamte Anlage in Betrieb, die heute ca. 1100 Wohnungen mit Waerme und Warmwasser versorgt. Die Erdwaermetiefensonde Prenzlau mit einer Tiefe von 2800 m deckte in den ersten beiden Betriebsjahren ueber 20 % des Waermebedarfs des Fernwaermenetzes Prenzlau-West. Die Jahresdauerleistung der Erdwaermetiefensonde mit 500 kW liegt bei 8-12 % der witterungsbedingten Jahreshoechstlast. Die Sonde gestattet Spitzenleistungen im Stundenbereich von mehr als 700 kW. (orig./AKF)

  8. CONFERENCE What happened at AMCO 7?

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1985-01-15

    The 7th International Conference on Atomic Masses and Fundamental Constants (AMCO-7), organized by the Gesellschaft fur Schwerionenforschung (GSI) and Technische Hochschule Darmstadt, was held in September at Seeheim, near Darmstadt. 150 participants from 19 countries met to discuss the progress in the field of measuring and calculating atomic masses as well as in related fields.

  9. CONFERENCE What happened at AMCO 7?

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The 7th International Conference on Atomic Masses and Fundamental Constants (AMCO-7), organized by the Gesellschaft fur Schwerionenforschung (GSI) and Technische Hochschule Darmstadt, was held in September at Seeheim, near Darmstadt. 150 participants from 19 countries met to discuss the progress in the field of measuring and calculating atomic masses as well as in related fields

  10. Meer proeven nodig om effect van hogere F-scatterwaarde te achterhalen : diffuus glas komt in de fase van fine-tuning (interview met Silke Hemming en Tom Dueck)

    OpenAIRE

    Kierkels, T.; Hemming, S.; Dueck, T.A.

    2014-01-01

    Diffuus glas is over vijftien jaar de standaard. Wie nu nieuw bouwt, heeft veel goede redenen om voor diffuus te kiezen en vrijwel geen om het te laten, zeggen Silke Hemming en Tom Dueck van Wageningen UR Glastuinbouw. De inzichten in het nut van diffuus licht én de technische ontwikkelingen schrijden nog elk jaar voort. Een update.

  11. Comparison of natural and synthetic diamond X-ray detectors

    International Nuclear Information System (INIS)

    Lansley, S. P.; Betzel, G.T.; Meyer, J.; Metcalf, P.; Reinisch, L.

    2010-01-01

    , the synthetic diamond detector performed well in comparison to the natural dia mond detector. Keywords X-ray detector Synthetic diamond Natural diamond Energy dependence Dose linearity . Dose-rate dependence X-ray detectors fabricated from diamond have been co sidered for many years, e.g. [1-5], for reasons including the near-tissue equivalence and high radiation tolerance of diamond, and low leakage current (which helps improve signal-noise ratio) due to high intrinsic resistivity. It is worth noting that, while diamond is described as near-tis sue equivalent because of its atomic number (Z = 6), the mass density of diamond (3.51 g/cm3) is much higher than water (1.00 g/cm/ muscle (1.06 g/cm3) [6] or fat (0.92 gl cm3) [7]. Natural diamond-based detectors for use in high-energy photon and electron beams are only commercially-avai able from Physikalisch- Technische Werkstatten GmbH (PTW, Freiburg, Germany) [8]; they were developed in cooperation with the IPTP Institute in Riga, Latvia. These detectors have a small sensitive volume (1-6 mm3) and hence are marketed as being especially well suited for

  12. Internet discussion forums as part of a student-centred teaching concept of pharmacology.

    Science.gov (United States)

    Sucha, Michael; Engelhardt, Stefan; Sarikas, Antonio

    2013-01-01

    The world wide web opens up new opportunities to interconnect electronic and classroom teaching and to promote active student participation. In this project article we describe the use of internet discussion forums as part of a student-centred teaching concept of pharmacology and discuss its advantages and disadvantages based on evaluation data and current literature. Final year medical students at the Technische Universität München (Munich, Germany) with the elective pharmacology moderated an internet forum that allowed all students to discuss pharmacology-related questions. Evaluation results of forum participants and elective students demonstrated a learning benefit of internet forums in pharmacology teaching. Internet discussion forums offer an easy-to-implement and effective way to actively engage students and increase the learning benefit of electronic and classroom teaching in pharmacology.

  13. Solid argon as a possible substrate for quasi-freestanding silicene

    KAUST Repository

    Sattar, Shahid; Hoffmann, R.; Schwingenschlö gl, Udo

    2014-01-01

    We study the structural and electronic properties of silicene on solid Ar(111) substrate using ab initio calculations. We demonstrate that due to weak interaction, quasi-freestanding silicene is realized in this system. The small binding energy of only meV per Si atom also indicates the possibility to separate silicene from the solid Ar(111) substrate. In addition, a band gap of 11 meV and a significant splitting of the energy levels due to spin-orbit coupling are observed. 2014 IOP Publishing Ltd and Deutsche Physikalische Gesellschaft.

  14. Solid argon as a possible substrate for quasi-freestanding silicene

    KAUST Repository

    Sattar, Shahid

    2014-06-03

    We study the structural and electronic properties of silicene on solid Ar(111) substrate using ab initio calculations. We demonstrate that due to weak interaction, quasi-freestanding silicene is realized in this system. The small binding energy of only meV per Si atom also indicates the possibility to separate silicene from the solid Ar(111) substrate. In addition, a band gap of 11 meV and a significant splitting of the energy levels due to spin-orbit coupling are observed. 2014 IOP Publishing Ltd and Deutsche Physikalische Gesellschaft.

  15. Neustart des LHC die Teilchenphysik hinter der Weltmaschine anschaulich erklärt

    CERN Document Server

    Knochel, Alexander

    2016-01-01

    In diesem essential gibt Alexander Knochel einen Überblick über aktuelle Probleme und offene Fragen der Teilchenphysik und Kosmologie und erläutert, wie der Large Hadron Collider zu ihrer Klärung beitragen kann. Dazu nimmt der Autor den Leser mit auf einen Streifzug durch neue physikalische Phänomene, die Grenzen unserer bisherigen Theorien und theoretische Überlegungen, was uns bei diesen bisher im Labor unerreichten Energieskalen erwarten könnte. Es wird spannend, denn der leistungsfähigste Teilchenbeschleuniger der Welt, der Large Hadron Collider, läuft wieder mit Rekordenergie!

  16. Technologien rund um orthopädische Implantate: Vortrag gehalten bei Prosthesia Meet & Match; Innovate in Orthopedic Implants; Innovez dans les Implants Orthopediques; Orthopaidsche Implantate: entwickeln wir sie weiter; Thursday, March 29th 2012, Illkirch

    OpenAIRE

    Schneider, Urs

    2012-01-01

    Die Innovationstreiber alternde Gesellschaft, dynamsiche Veränderungen in der Gesundheitspolitik der Zielländer, spezielle Marktveränderungen im Gesundheitswesen, Technologietrends und Fortentwicklung orthopädischer Therapieverfahren werden diskutiert. Im Forschungsfeld neuer Materialien hat die Welt der orthopädischen Implantate mittlerweile alle anderen Medizintechnikfelder hinter sich gelassen. Neue technische Lösungen des Fraunhofer IPA und der Fraunhofer Gesellschaft werden vorgestellt....

  17. Grundlagen der zeichnerischen Darstellung

    Science.gov (United States)

    Döring, Peter

    Eine Technische Zeichnung muss nach DIN 6774 Teil 1 in der Weise angefertigt werden, dass sie übersichtlich, unmissverständlich, auch in verkleinertem Maßstab lesbar bleibt, kostengünstig reproduzierbar und dauerhaft archivierbar ist. Zu dem Zweck benötigt man entsprechendes Papier und angepasstes Zeichengerät. Heute ist die Anfertigung mit entsprechenden Rechnerprogrammen möglich.

  18. Verletzungen und Fehlbeanspruchungen im leistungsorientierten Rudersport

    OpenAIRE

    Bussian, Marc Robert

    2004-01-01

    Die Stellung der Breitensportart Rudern als gesundheitsfördernde Sportform ist in der Literatur gleichlautend positiv beschrieben. Im leistungsorientierten Rudersport müssen neben den Verletzungen und Fehlbeanspruchungen der eigentlichen Sportart die unabdingbaren Nebentrainingsformen berücksichtigt werden. In den neunziger Jahren vollzog sich ein trainingsmethodischer Wandel, die Einführung eines erschwinglichen Rudersimulators und eine technische Weiterentwicklung im Boots- und Ruderbau. Ei...

  19. First performance results of two novel spectroradiometers developed for fast scanning of solar spectra UV irradiance

    Science.gov (United States)

    Feister, Uwe; Kaifel, Anton K.; Grewe, Rolf-Dieter; Kaptur, Jasmine; Reutter, Oliver; Wohlfart, Michael; Gericke, Klaus

    2003-11-01

    time of the SPECTRO 320D was 23 s. The two spectroradiometers, which both have been absolutely calibrated in the DWD lab using FEL 1000 W halogen lamps traceable to the German Physikalisch-Technische Bundesanstalt (PTB), were used in a field campaign at Izana (Tenerife Island) at a height of 2409 m to compare measured spectral and integral values of solar irradiance. Results of that comparison and the instruments" characteristics revealed under those special field conditions will be discussed.

  20. Development of a lauric acid/albumin hybrid iron oxide nanoparticle system with improved biocompatibility

    Directory of Open Access Journals (Sweden)

    Zaloga J

    2014-10-01

    Full Text Available Jan Zaloga,1 Christina Janko,1 Johannes Nowak,2 Jasmin Matuszak,1 Sabine Knaup,1 Dietmar Eberbeck,3 Rainer Tietze,1 Harald Unterweger,1 Ralf P Friedrich,1 Stephan Duerr,1 Ralph Heimke-Brinck,4 Eva Baum,4 Iwona Cicha,1 Frank Dörje,4 Stefan Odenbach,2 Stefan Lyer,1 Geoffrey Lee,5 Christoph Alexiou1 1Department of Otorhinolaryngology, Head and Neck Surgery, Section for Experimental Oncology and Nanomedicine (SEON, Else Kröner-Fresenius-Stiftung-Professorship, University Hospital Erlangen, Erlangen, Germany; 2Measuring and Automation Technology, Technical University Dresden, Dresden, Germany; 3Physikalisch-Technische-Bundesanstalt, Berlin, Germany; 4Pharmacy Department, University Hospital Erlangen, Erlangen, Germany; 5Division of Pharmaceutics, Friedrich Alexander University Erlangen-Nuremberg, Erlangen, Germany Abstract: The promising potential of superparamagnetic iron oxide nanoparticles (SPIONs in various nanomedical applications has been frequently reported. However, although many different synthesis methods, coatings, and functionalization techniques have been described, not many core-shell SPION drug delivery systems are available for clinicians at the moment. Here, bovine serum albumin was adsorbed onto lauric acid-stabilized SPIONs. The agglomeration behavior, zeta potential, and their dependence on the synthesis conditions were characterized with dynamic light scattering. The existence and composition of the core-shell-matrix structure was investigated by transmission electron microscopy, Fourier transform infrared spectroscopy, and zeta potential measurements. We showed that the iron oxide cores form agglomerates in the range of 80 nm. Moreover, despite their remarkably low tendency to aggregate even in a complex media like whole blood, the SPIONs still maintained their magnetic properties and were well attractable with a magnet. The magnetic properties were quantified by vibrating sample magnetometry and a superconducting quantum

  1. Concepts for `superior process control` in the energy industry; Konzepte fuer die uebergeordnete Prozessfuehrung in der Energiewirtschaft

    Energy Technology Data Exchange (ETDEWEB)

    Doellen, U.C. von

    1996-12-01

    The work concerns the task of control described as dispatching of extensive energy supply and distribution networks. Due to the special contractual situation, there are special long-term targets in firms, which must be achieved in addition to the extensive operational tasks of control and monitoring of the networks. The concepts introduced in the work offer a framework for a target-orientated design of computer-aided menus for this superior process control in the energy industry. (orig./GL) [Deutsch] Die Arbeit betrachtet die als Dispatching bezeichnete Aufgabe der Fuehrung ausgedehnter Energieversorgungs- und verteilungsnetze. Aus den speziellen Vertragssituationen ergeben sich in den Unternehmen besondere, langfristige Zielvorgaben an die mit der Betriebsfuehrung beauftragen Operateure, die zusaetzlich zu den umfangreichen operativen Aufgaben der Fuehrung und Ueberwachung der Netze zu erreichen sind. Die in der Arbeit vorgestellten Konzepte bieten den Rahmen fuer einen zielgerichteten Entwurf rechnergestuetzter Hilfsmittel fuer diese uebergeordnete Prozessfuehrung in der Energiewirtschaft. Das erstellte Gesamtsystem wird abschliessend zur Loesung einer konkreten, energiewirtschaftlichen Problemstellung eingesetzt. Die entwickelte Anwendungsloesung wird als Hilfsmittel fuer die technische und vertragliche Optimierung im Dispatching eingesetzt. Wesentliche Zielsetzung ist ein technisch und wirtschaftlich optimaler Einsatz von Energiespeichern zur Deckung von Spitzenlasten. (orig./GL)

  2. Technical measurement of pressure and force; 2. new rev. and enl. ed.; Technische Druck- und Kraftmessung

    Energy Technology Data Exchange (ETDEWEB)

    Bonfig, K.W. [Siegen Univ. (Gesamthochschule) (Germany). Inst. fuer Messtechnik; Bill, B. [Kistler Instrumente AG, Winterhthur (Switzerland); Haase, H.J. [Siemens AG, Karlsruhe (Germany); Kloucek, F.; Martini, K.H. [Kistler Instrumente AG, Winterhthur (Switzerland); Mueller, R. [Schenck (C.) AG, Darmstadt (Germany); Paetow, J. [Hottinger Baldwin Messtechnik GmbH, Darmstadt (Germany)

    1995-12-31

    The methods used in the field of technical measurement of pressure and force which employ an electric, pressure-proportional output signal have been increasingly applied over the last years. Methods with inductive and capacitative transducers or wire strain gauge transducers have been continuously further developed and perfected. Transducers which use piezoelectrical or piezoresistive methods are also widely applied. This book describes a large number of typical applications and solutions to problems in the fields of research, development, manufacturing and project development. (orig./GL). 135 figs, 3 tabs., 126 refs. [Deutsch] Auf dem Gebiet der technischen Druck- und Kraftmessung haben die Verfahren, bei denen ein elektrisches, druckproportionales Ausgangssignal abgegeben wird, in den letzten Jahren eine staendig zunehmende Anwendung gefunden. So sind die Verfahren mit induktiven und kapazitiven Aufnehmern ebenso wie die mit Dehnungsmessstreifen-Aufnehmern staendig weiterentwickelt und vervollkommnet worden. Daneben haben auch die Messwertaufnehmer, die nach dem piezoelektrischen oder dem piezoresistiven Verfahren arbeiten, starke Verbreitung gefunden. Ausserdem werden Ausfuehrungen fuer spezielle industrielle Einsatzfaelle dargestellt. Besonderes Gewicht wird bei den einzelnen Beitraegen auf die Darstellung von typischen Anwendungsbeispielen und Problemloesungen in Forschung, Entwicklung, Fertigung und Projektierung gelegt. (orig./GL)

  3. Communication of technical building systems. Fundamentals; Kommunikation technischer Gebaeudesysteme. Grundlagen

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    In chapter 17 of the anthology about building control the communication between and with technical building systems is described. The following aspects are discussed: From the matrix cable to the standard bus, data transmission, communication terms, components of communication systems, type of data transmission, types of connection, networks, protocols, the ISO/OSI reference model, application of automation in the field of communication, services and profiles, communication objects. (BWI) [Deutsch] Kapitel 17 des Sammelbandes ueber Building Control ist dem Thema der Kommunikation zwischen und mit technischen Gebaeudesystemen gewidmet. In diesem Zusammenhang werden folgende Themen angesprochen: Vom Matrixkabel zum Standard-Bus; Daten-Transport; Kommunikations-Begriffe; Komponenten der Kommunikations-Systeme; Art der Datenuebertragung; Verbindungsarten, Netze, Protokolle; Das ISO/OSI Referenzmodell; Automation als Anwendung in der Kommunikation; Dienste und Profile; Kommunikationsobjekte. (BWI)

  4. Derivation of the Photosynthetically Available Radiation from METEOSAT data

    Energy Technology Data Exchange (ETDEWEB)

    Schiller, K. [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. fuer Hydrophysik

    2001-07-01

    Two different models, a Physical Model and a Neural Net, are used for the derivation of the photosynthetically available radiation (PAR) from METEOSAT data in the German Bight. Both models are constructed for the calculation of PAR in the German Bight in terms of an easily accessible time series of PAR fields; advantages and disadvantages of both models are discussed. A software package was generated in IDL for the realisation on the computer, its structure is motivated and physic background informations are given. With slight modifications all programs can be applied for the calculation of PAR for arbitary regions (but not over land). A zip file containing all programs and classes used, the technical html documentation and this report can be obtained from http://gfesunl.gkss.de/software/meteosat2par. (orig.) [German] Zur Ableitung der zur Photosynthese zur Verfuegung stehenden Strahlung (PAR) in der Deutschen Bucht aus METEOSAT-Daten werden zwei verschiedene Modelle, ein Physikalisches Modell und ein Neuranales Netz, benutzt. Beide Modelle sind darauf ausgelegt, PAR in der Deutschen Bucht in Form einer einfach zugaenglichen Zeitreihe von PAR-Feldern zu berechnen; Vor- und Nachteile beider Modelle werden diskutiert. Zur Realisierung auf dem Computer wurde ein Programmpaket in IDL erstellt, dessen Struktur motiviert wird und physikalische Hintergruende erlaeutert werden. Alle Programme sind so angelegt, dass sie sich durch geringfuegige Modifikationen eignen, PAR auch fuer andere Gebiete (aber nicht ueber Land) zu berechnen. Ein Zip-File aller benutzter Programme, Klassen, der technischen Html-Dokumentation und dieses Berichtes kann bei http://gfesunl.gkss.de/software/meteosat2par bezogen werden. (orig.)

  5. Urban regeneration featuring environmental quality, the management of resources and social cohesion

    Directory of Open Access Journals (Sweden)

    Alessandra Battisti

    2015-11-01

    Full Text Available This scientific project – developed over the past two years by Sapienza University’s PDTA in Rome, in partnership with the Technische Universität München, funded by the German DAAD – took as its starting point the differences between the buildings found in the consolidated/ historic city’s districts and the city’s continually evolving environmental, energy, technological, functional and social needs, creating urban situations where it becomes clear that it is not enough to regenerate individual buildings in environments that are gradually changing; rather it is necessary to take action on districts and widespread city clusters. The pilot case studied was the regeneration of two districts that were part of consolidated, yet neglected, areas in the city of Rome, the result was mainly geared towards determining the level of transferability of the results of this experiment. 

  6. Künstliche Menschen? Körpergeschichte zwischen Wissenschafts- und Technikgeschichte Artificial Humans? The History of the Body between the History of Science and of Technology

    Directory of Open Access Journals (Sweden)

    Pascal Eitler

    2006-11-01

    Full Text Available Der vorliegende von Barbara Orland herausgegebene Sammelband steht in einer Reihe von Untersuchungen, in denen seit rund zehn Jahren der menschliche Körper in seiner Historizität als Ergebnis wissenschaftlicher und technischer Konstruktionsprozesse betrachtet wird. In dreizehn Beiträgen wird mittels unterschiedlicher Zugriffe und auf durchweg hohem Niveau ein denkbar breites Feld der artifiziellen Gestaltung menschlicher Körper seit dem 18. Jahrhundert erschlossen.The collected volume at hand, edited by Barbara Orland, is one of a series of studies on the human body in the past ten years that examines its historicity on the basis of scientific and technical processes of construction. In its thirteen contributions, which use various approaches and which display consistently high standards, the collection opens up the considerably wide field of the artificial construction of the human body since the eighteenth century.

  7. Construction of the CMS Tracker End-Caps and an Impact Study on Defects

    CERN Document Server

    Linn, Alexander

    2008-01-01

    The CMS experiment at the LHC accelerator at the research center CERN close to Geneva will study proton proton collisions at up to now unprecedented centre of mass energies from the year 2008 on. To discover theoretically predicted elementary particles, CMS was equipped with the largest silicon tracker so far with a sensitive area of 198m2. Partitioned into more than 15.000 silicon strip modules, the construction and test of the tracker was a huge challenge for the involved institutes. The III. Physikalisches Institut B of the RWTH Aachen had a leading role in the construction and test of substructures, so called petals, for the end caps of the tracker. The petals were assembled in a clean room and underwent first basic tests to ensure the general operationability of each component. Failures detected during the assembly are described and improvements of the silicon strip modules are discussed. After the assembly the petals underwent a cold test for several days. For the first time all readout components of th...

  8. Activities of the TUV experts during the period of construction and commissioning of a nuclear power plant ordered by the licensing authorities of the FRG

    International Nuclear Information System (INIS)

    Dommke, J.; Fendler, H.

    1977-01-01

    The inspection organisations in the Federal Republic of Germany (Technische Uberwachungs-Vereine) are independent systems grouped on a regional basis. The competent licensing authorities of the various Lander consult them concerning assessments for site selection and the design, construction, commissioning and operation of nuclear power plants. Furthermore the TUV experts inspect the manufacture of components in the suppliers' facilities and on site. (NEA) [fr

  9. Die Invariantendarstellung in der Satellitengradiometrie : theoretische Betrachtungen und numerische Realisierung anhand der Fallstudie GOCE

    OpenAIRE

    Baur, Oliver

    2007-01-01

    Die Satellitengradiometrie (Satellite Gravity Gradiometry, SGG) ist die derzeit modernste Technik zur Bestimmung und Modellierung hochauflösender Gravitationsfelder. Sie gründet auf der Beobachtung zweiter Ableitungen des Gravitationspotenzials, welche als Gravitationsgradienten (GG) bezeichnet werden und deren Gesamtheit im Gravitationstensor (oder Eötvös-Tensor) zusammen gefasst ist. Letzterer zeichnet sich durch Symmetrie und Spurfreiheit aus. Technisch realisiert wird die Gradiometrie übe...

  10. Authenticiteit en contracteren omtrent kunst : een rechtsvergelijkende analyse.

    OpenAIRE

    Demarsin, Bert

    2008-01-01

    JURIDISCH-TECHNISCHE TOELICHTING Dit proefschrift is opgebouwd in drie delen. Deel I biedt een interdisciplinair onderzoek naar het authenticiteitsbegrip dat niet alleen vanuit juridisch, maar ook vanuit kunsthistorisch en filosofisch oogpunt ontleed wordt. Delen II en III bouwen vervolgens verder op het aldus ontwikkelde begrippenapparaat. Deel II richt zich op de authenticiteitsproblematiek in de rechtstreekse verhouding tussen de koper en de verkoper van een kunstvoorwerp. De analyse ...

  11. Thermal analysis of electric power generation with solar collectors at how low temperature; Analisis termico de plantas de generacion de energia electrica con la integraacion de colectores solares trabajando a bajas temperaturas

    Energy Technology Data Exchange (ETDEWEB)

    Monne, C.; Salina, P.; Leithner, R.; Aronis, N.

    2004-07-01

    The main focus of this article is how low temperature heat sources can be used for electric power generation. The paper will focus on solar energy in particular. The article shows simulation of five different cycles, with solar energy integration, by means ENBIPRO program (ENergie-BIlanz-PROgramm), that at the moment it is being developed by Institut Warme und Brennstofftechnik, Technische Universitat Braunschweig (Germany). (Author)

  12. A domain specific language for the automatic generation of parsers classes for text protocols

    OpenAIRE

    Kistel, Thomas; Vandenhouten, Ralf

    2014-01-01

    ABNF ist eine Sprache zur Definition einer formalen Syntax für technische Spezifikationen und wird häufig zur Beschreibung textueller Nachrichten von Internetprotokollen eingesetzt. Die Möglichkeiten der automatischen Generierung von Parser-Klassen aus ABNF-Spezifikationen sind derzeit sehr begrenzt, da ABNF lediglich die Transfersyntax und Produktionsregeln von Textnachrichten beschreibt. Die fehlende Definition von Variablennamen innerhalb einer ABNF-Spezifikation ermöglicht es nicht, sinnv...

  13. The Bgo-Od Experiment at Elsa

    Science.gov (United States)

    Bantes, B.; Bayadilov, D.; Beck, R.; Becker, M.; Bella, A.; Bieling, J.; Böse, S.; Braglieri, A.; Brinkmann, K.; Burdeynyi, D.; Curciarello, F.; de Leo, V.; di Salvo, R.; Dutz, H.; Elsner, D.; Fantini, A.; Frese, T.; Friedrick, S.; Frommberger, F.; Ganenko, V.; Gervino, G.; Ghio, F.; Giardina, G.; Girolami, B.; Glazier, D.; Goertz, S.; Gridnev, A.; Gutz, E.; Hammann, D.; Hannappel, J.; Hillert, W.; Ignatov, A.; Jahn, O.; Jahn, R.; Joosten, R.; Jude, T. C.; Klein, F.; Koop, K.; Krusche, B.; Lapik, A.; Levi Sandri, P.; Lopatin, I.; Mandaglio, G.; Messi, F.; Messi, R.; Metag, V.; Moricciani, D.; Nanova, M.; Nedorezov, V.; Noviskiy, D.; Pedroni, P.; Romaniuk, M.; Rostomyan, T.; Schaerf, C.; Schmieden, H.; Sumachev, V.; Tarakonov, V.; Vegna, V.; Vlasov, P.; Walther, D.; Watts, D.; Zaunick, H.-G.; Zimmermann, T.

    2014-01-01

    Meson photoproduction is a key tool for the experimental investigation of the nucleon excitation spectrum. To disentangle the specific couplings of resonances, in addition to the rather well measured pion and eta photoproduction channels it is mandatory to obtain information on channels involving strange and vector mesons and higher mass pseudoscalar mesons, and the associated multi-particle final states with both charged and neutral particles. In this respect, the new BGO-OD experiment at the ELSA accelerator of the University of Bonn's Physikalisches Institut provides unique instrumentation. We describe the experiment, present its status and the initial program of measurements.

  14. Automation of a gamma spectrometric analysis method for naturally occuring radionuclides in different materials (NORM)

    International Nuclear Information System (INIS)

    Marzocchi, Olaf

    2009-06-01

    This work presents an improvement over the standard analysis routine used in the Physikalisches Messlabor to detect gamma peaks in spectra from naturally occurring radioactive materials (NORM). The new routine introduces the use of custom libraries of known gamma peaks, in order to ease the work of the software than can therefore detect more peaks. As final result, the user performing the analysis has less chances of making errors and can also analyse more spectra in the same amount of time. A new software, with an optimised interface able to further enhance the productivity of the user, is developed and validated. (orig.)

  15. Implementation of new concepts for space HVAC systems in domestic buildings in consideration of cost, consumption and user comfort. Final report; Umsetzung neuer Konzepte der technischen Gebaeudeausruestung im Wohnungsbau unter Beruecksichtigung von Kosten, Verbraeuchen und Nutzerkomfort. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, F.; Sucic, D.; Wendler, M.

    1998-03-01

    The goal of this project was the development of a set of tools for the selection of optimal concepts for HVAC-systems in housing buildings. Several factors are considered. They include technical feasibility, costs for investment, maintenance and operation, energy concumption, environmental impacts and user comfort. It is intended with the help of these tools to identify the most important factors which influence energy consumption and to suggest simple and cost effective measures to reduce energy consumption. Measures include improvements of the envelope, changes in the HVAC-system and its operation according to the needs to the inhabitants of the building. This report describes these components of this tool set which were developed in the frame of the project WohnKomfort. It lists data and rules chosen. In addition we report experiences which we gained with an prototypical implementation. This implementation allows load calculations for more than 60.000 different buildings applying EN 802 (only one zone model) as calculation method. It also supports selection of heating systems for such buildings by offering an evaluation according to user specified criteria including cost, environment and comfort. (orig./MM) [Deutsch] Ziel des Vorhabens war die Entwicklung eines Instrumentariums zur Auswahl optimaler Konzepte fuer technische Anlagen in Wohngebaeuden unter Beruecksichtigung der Faktoren technische Machbarkeit, Erstellungs-, Betriebskosten, Energieverbrauch, Umweltbelastung und Nutzerkomfort. Mit Hilfe dieses Instrumentariums soll es moeglich werden, die Haupteinflussfaktoren fuer den Energieverbrauch anzugeben und Vorschlaege fuer einfache und kostenguenstige Massnahmen zu seiner Reduzierung auf der Seite des Gebaeudes (bauliche Massnahmen) und der Anlage (technische Massnahmen, Nutzerverhalten) anzugeben. In diesem Bericht beschreiben wir die im Vorhaben entwickelten Komponenten des Instrumentariums, die zugrundeliegenden Daten und Regeln sowie Erfahrungen, die

  16. PLANNING IN ARTIFICIAL INTELLIGENCE AND ROBOTICS (PAIR

    Directory of Open Access Journals (Sweden)

    Editorial, Foreword

    2016-11-01

    Full Text Available September 18th, 2016Deggendorf, Germanyhttp://robotics.fel.cvut.cz/pair16/Organized by: Artificial Intelligence Center Department of Computer Science Faculty of Electrical Engineering Czech Technical University in PragueTechnicka 2, Prague 6, 166 27, Czech RepublicGuest editors:Jan Faigl (Artificial Intelligence Center, Department of Computer Science, Faculty of Electrical Engineering, Czech Technical University in PragueJiří Vokřínek (Artificial Intelligence Center, Department of Computer Science, Faculty of Electrical Engineering, Czech Technical University in PragueScientific comittee:D. Belter (Poznań University of Technology, PolandW. Dorner (Technische Hochschule Deggendorf, GermanyJ. Faigl (Czech Technical University in PragueT. Krajník (University of Lincoln, United KingdomA. Komenda (Czech Technical University in PragueG. Kupris (Technische Hochschule Deggendorf, GermanyM. Rollo (Czech Technical University in PragueM. Saska (Czech Technical University in PragueJ. Vokřínek (Czech Technical University in PragueV. Vonásek (Czech Technical University in PragueK. Walas (Poznań University of Technology, Poland Foreword:The third year of the student conference on “Planning in Artificial Intelligence and Robotics” (PAIR continues in joining young researchers and students interested in robotics and artificial intelligence. In 2016, we follow the schema of the last year as a joint event with the RoboTour competition in Deggendorf, Germany. Thanks to the great collaboration with Gerald Kupris and Wolfgang Donner from Technische Hochschule Deggendorf and support from Czech Technical University under project No. SVK 26/16/F3 and Bayerisches Staatsministerium der Finanzen, für Landesentwicklung und Heimat, we have been able to provide accommodations and travel support to participants and an invited speaker. Fourteen papers have accepted and listed in the conference program. The papers have been authored by students from Central Europe

  17. Normzahlen, Toleranzen, Passungen

    Science.gov (United States)

    Böge, Gert; Böge, Wolfgang

    Vor allem wegen der Kosten ist es sinnvoll, sich beim Festlegen von Maßen aller Art auf Vorzugszahlen zu beschränken (Baugrößen, Drehzahlen, Drehmomente, Leistungen, Drücke usw.). Man verwendet dazu eine geometrisch gestufte Zahlenfolge (siehe Teil Mathematik). Abb. 40.1 zeigt, dass bei der geometrischen Stufung die Werte im unteren Bereich fein, im oberen grob gestuft sind. Das ist nicht nur technisch sinnvoll.

  18. Integrative Lifecourse and Genetic Analysis of Military Working Dogs

    Science.gov (United States)

    2015-12-01

    Multhoff, Technische Universitaet Muenchen, GERMANY Received: July 22, 2015 Accepted: October 15, 2015 Published: November 11, 2015 Copyright: © 2015...MO) were used. For the monolayer model, cells were plated in 96-well black flat-clear bottom plates (Greiner Bio-One GmbH, Frickenhausen, Germany ...and oncogenic determinants of metastasis have been reported and appear to be similar in both species. Comparative analysis of deregulated gene sets or

  19. Eindhoven trendsetter with Smart Light Grid; Eindhoven voorloper met Slim Light-Grid

    Energy Technology Data Exchange (ETDEWEB)

    Van Lieshout, M.

    2013-07-15

    The municipality of Eindhoven in the Netherlands asked the Intelligent Lighting Institute of the Technical University of Eindhoven to develop a vision and a roadmap for urban lighting for 2030 in cooperation with private partners [Dutch] De gemeente Eindhoven heeft het Intelligent Lighting Institute van de Technische Universiteit Eindhoven gevraagd een visie en een roadmap te ontwikkelen voor stedelijke verlichting voor 2030. Samen met private partners moet dit worden uitgevoerd.

  20. Utilisation of service water and rainwater: New technologies for rainwater management; Betriebs- und Regenwassernutzung: neue Wege im Umgang mit Regenwasser

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, E.

    2005-04-01

    The new 'Holocaust Memorial' in Berlin near the Brandenburg gate has specially developed, unusual technical solutions for service water and rainwater management. Details are presented in the contribution. (orig.) [German] Nur wenige Minuten vom Brandenburger Tor entsteht in Berlin das 'Denkmal fuer die ermordeten Juden in Europa'. Fuer die Betriebswasserver- und -entsorgung wurden spezielle und aussergewoehnliche technische Loesungen gefordert, die nachfolgend naeher beschrieben werden. (orig.)

  1. Mediengestaltung im interkulturellen Vergleich. Eine Studie zu Mikroaspekten der Globalisierung

    OpenAIRE

    Vera-Stahl, Gilda

    2017-01-01

    Die vorliegende Arbeit befasst sich mit dem interkulturellen Vergleich von lokalen Werbespots aus Deutschland und Ecuador. Im Zentrum des Interesses steht die implizite Dimension der technisch gebundenen audiovisuellen Kommunikation, d.h. die Art und Weise, wie die Kommunikationsmedien – das Bild, die Sprache und die Musik – bei der Gestaltung der Spots verwendet werden. Ausgangspunkt der Untersuchung bildet der Ansatz von Nothnagel/Vera (2004, 2005), dass Habitusformen der Face-to-Face-...

  2. Graph Structure Theory: Proceedings of a Joint Summer Research Conference on Graph Minors Held June 22 to July 5, 1991, at the University of Washington, Seattle. Contemporary Mathematics 147

    Science.gov (United States)

    1991-01-01

    Rudolf Miiller, A combinatorial approach to obtain bounds for stochastic project neworka, Tech. report, Technische Universitit Berlin, 1991. [Pou851 M...appear). 600 ANDRZEJ PROSKUROWSKI [201 J.A. Wald and C.J. Colbourn, Steiner trees, partial 2-trees, and minimum IFI networks, Networks 13 (1983), 159-167...Colbourn, Steiner trees, partial 2-trees and minimum IFI networks, Networks 13, (1983), 159-167. DEPARTMENT OF COMPUTER SCIENCE, UNIVERSITY OF

  3. Absolute Measurement of Radioactive Materials at the Physikalisch-Technische Bundesanstalt; Mesure absolue des substances radioactives a l'Institut federal de physique appliquee; Absolyutnoe izmerenie radioaktivnykh veshchestv v fiziko-tekhnicheskom federal'nom institute; Determinacion absoluta de la actividad de sustancias radiactivas en el Instituto Federal de Fisica Aplicada

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, H M [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1960-06-15

    A short report is given about the routine methods of standardization of radionuclides. The measurements are done by 4 {pi} {beta} proportional counters, 4 {pi} {beta}-{gamma} coincidence counting and for secondary standardization of {gamma} emitters by 4 {pi} {gamma} ionization chamber. The equipments used and the procedures of source preparation are described. (author) [French] L'auteur presente un rapport succinct sur les methodes courantes de normalisation des radionuclides. Les mesures sont effectuees au moyen de compteurs proportionnels 4 {pi} {beta}, par voie de comptage par coincidences 4 {pi}{beta}-{gamma} et, en ce qui concerne la normalisation secondaire des emetteurs de rayons {gamma}, au moyen d'une chambre d'ionisation 4 {pi} {gamma}. Le memoire contient une description du materiel utilise et des procedes employes pour la preparation des sources. (author) [Spanish] En la memoria se describen brevemente los metodos corrientes de calibracion de radionuclidos. Las mediciones a que se refiere se han efectuado con contadores proporcionales {beta} 4 {pi}, contadores de coincidencias {beta}-{gamma} 4{pi}l; para la calibracion secundaria de emisores {gamma} se ha utilizado una camara de ionizacion {gamma} 4 {pi}. Se describen los aparatos empleados y los procedimientos de preparacion de las fuentes. (author) [Russian] Privoditsya kratkij doklad po obychnym metodam standartizatsi i radioizotopov. Izmereniya osushchestvlyalis {beta}-proportsional'nym i schetchikami na 4 {pi}, schetchikami {beta}-{gamma} sovpadenij i {gamma}-ioniziruyushche j kameroj na 4 i dlya vtorichnoj standartizatsi i {gamma}-izluchatelej . Privoditsya opisanie, ispol'zuemogo oborudovaniya i protsedura podgotovki istochnika. (author)

  4. The light goes on in the bush. Solar energy for Senegal. Im Busch geht das Licht an. Solarenergie fuer den Senegal

    Energy Technology Data Exchange (ETDEWEB)

    Eckert, H.

    1990-08-01

    The article is about a joint project between Germany and Senegal for the 'testing and propagation of photovoltaic solar power systems', sponsored by Deutsche Gesellschaft fuer Technische Zusammenarbeit (GTZ). The project, scheduled at present for a duration of five years (1987-1991), receives grants of just under DM 21 million and is to demonstrate to the rural population of the Western African state of Senegal how to meet their basic electric power demand for lighting, radio and television, because only a fraction of the more than 13 000 Senegalese villages may expect to be connected to the national power grid during the decades to come. Distances are too long and consumption rates too small to erect a conventional power grid at reasonable cost in this large country covering 200 000 km{sup 2} and populated by just under 10 million inhabitants only. (orig./ORU).

  5. Service planning. Methods for quality assurance in manufacturing; Instandhaltungs-Planung. Methoden zur Qualitaetssicherung in der Fertigung

    Energy Technology Data Exchange (ETDEWEB)

    Lapp, H.

    1995-12-31

    Servicing is the generic term for inspection, maintenance and repair. It is largely carried out using quality-oriented methods as are laid down in DIN EN ISO 9000 ff. Service planning is an investment in the future which will become more important with growing automisation of production plants. Planned servicing reduces risks and protects against accidents, excessive downtime, and damage to movable property and buildings. The present book addresses servicemen from industry, craftsman`s establishments, and service planners who deal with the servicing of mchanical installations. It contains examples of planning which may serve the reader as a guide and stimulus for his or her own work. Rather than providing detailed solutions the examples offer hints and information on how to go about one`s own service planning. Tables containing technical terms and proposals for schedule and checklist forms and operating sheets offer guidance in setting up one`s own service planning. Planned servicing contributes to prolonging service life, increasing the value and ensuring maximum operability of an installation. Service planning includes the elaboration of schedules, codable operating sheets, material lists, test certificates, error reports, damage reports, and analyses of weak points. Operators of production plants can procure these planning tools also in the form of software. Coding of different types of maintenance work, damaged parts and damage patterns (terminology of defects) makes it possible to call for maintenance tenders from other companies. (orig.) [Deutsch] Instandhaltung ist der Oberbegriff fuer Inspektion, Wartung und Instandsetzung. Im Vordergrund stehen qualitaetsorientierte Methoden gemaess DIN EN ISO 9000 ff. Geplante Instandhaltung ist eine Investition fuer die Zukunft; sie wird mit der weiteren Automatisierung der Produktionsanlagen an Bedeutung gewinnen. Die geplante Instandhaltung reduziert das Risiko und schafft Sicherheit vor Unfaellen, Produktionsausfaellen, Sach- und Gebaeudeschaeden. Dieses Buch wendet sich an Instandhalter der Industrie und an Handwerksbetriebe sowie an Instandhalterplaner, die sich mit der Instandhaltung mechanischer Anlagen beschaeftigen. Es enthaelt Planungsbeispiele, die als Anleitung und Anregung fuer die eigene Arbeit gedacht sind. Die Beispiele sind keine Rezepte, sondern sollen Tips und Hinweise geben fuer eigene Ueberlegungen zur Planung der Instandhaltung. Tabellen mit Begriffen und Formularvorschlaegen zur Erstellung von Terminplaenen, Checklisten und Arbeitskarten geben Hilfestellung beim Aufbau einer eigenen Instandhalteplanung. Geplante Instandhaltung traegt dazu bei, dass die Nutungsdauer der Anlagen verlaengert, der Anlagenwert verbessert und die maximale Einsatzbereitschaft gewaehrleistet wird. Die Instandhalteplanung umfasst neben der Erstellung von Terminplaenen, codierbaren Arbeitskarten und Betriebsmittellisten auch Messprotokolle, Maengelberichte, Schadensmeldungen und Schwachstellenanalysen. Vorgenannte Planung kann auch den Betreibern von Fertigungsanlagen ueber EDV angeboten werden. Durch die Codierung der Instandhaltetaetigkeiten, Schadensteile und Schadensbilder (Maengelbegriffe) koennen auch Instandhalte-Angebote von Fremdfirmen eingeholt werden. (orig.)

  6. Dust precipitation nuisance in the Rhine lignite basin. Situation analysis, legal assessment and the use of compost recycling for emission-protection purposes; Die Staubniederschlagsbelastungen im Rheinischen Braunkohlenrevier. Situationsanalyse, rechtliche Bewertung und Verwertung von Kompost zu Immissionsschutzzwecken

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, P. [Bergamt Dueren (Germany)

    2004-03-01

    The paper describes the problem of dust precipitation in the Rhine lignite basin and presents a legal, scientific and technical assessment of how composting can be used for emission protection purposes, along with supporting measures such as the replanting of opencast mining sites. Also examines the benefits, and possible risks, associated with waste recycling projects of this kind. The results of the investigations show that compost recycling for emission-protection purposes can be used to support the emission-protection measures previously deployed at opencast mines in the Rhine lignite basin, including the grassing-over of former mine sites. Such measures are now considered to be technically feasible, environmentally compatible and lawful, and indeed are considered necessary in some circumstances. (orig.) [German] Die Arbeit beschreibt die Staubniederschlagsbelastungen im Rheinischen Braunkohlenrevier und bewertet in diesem Zusammenhang den Einsatz von Kompost zu Immissionsschutzzwecken einschliesslich einer unterstuetzenden Begruenung in den Tagebauen in rechtlicher sowie naturwissenschaftlich-technischer Hinsicht. Darueber hinaus wird die Nuetzlichkeit und Schadlosigkeit dieser Abfallverwertungsmassnahmen beurteilt. Nach den Ergebnissen dieser Arbeit ist eine Kompostverwertung zu Immissionsschutzzwecken zur Ergaenzung des bisherigen Immissionsschutzsystems in den Tagebauen des Rheinischen Braunkohlenreviers einschliesslich einer unterstuetzenden Begruenung technisch moeglich, umweltvertraeglich und rechtlich zulaessig sowie unter bestimmten Voraussetzungen erforderlich. (orig.)

  7. Solar-assisted district heating systems: The Solarthermie 2000-programme; Solarunterstuetzte Nahwaermeversorgung: Programm Solarthermie-2000

    Energy Technology Data Exchange (ETDEWEB)

    Lottner, V. [Forschungszentrum Juelich GmbH (Germany). Projekttraeger Biologie, Energie, Umwelt (BEO)

    1998-12-31

    In Germany, utilisation of solar energy for thermal energy supply has a considerable technical and economic potential in terms of substitution of fossil fuels and reduction of CO{sub 2} emission. If appropriate technologies are used, solar-assisted district heat supply systems can be a cost-efficient concept for thermal utilisation of solar energy. The BMBF -programme `Solarthermie 2000` supports a number of pilot and demonstration plants in order to test and develop the most promising systems and storage facilities under real conditions. Long-term measuring programmes generate reliable data on thermal performance and cost of the plant concepts and create a solid basis for a technical and economic evaluation. (orig.) [Deutsch] Die Nutzung von Solarenergie fuer die Waermeversorgung bietet in Deutschland ein grosses technisches und wirtschaftliches Potential zur Substitution fossiler Energietraeger und Reduzierung der CO{sub 2} Emissionen in die Atmosphaere. Solarunterstuetzte Nahwaermesysteme stellen unter guenstigen technischen Bedingungen ein kostenguenstiges Konzept der thermischen Nutzung der Solarenergie dar. In dem BMBF-Programm Solarthermie-2000 werden Pilot- und Demonstrationsanlagen gefoerdert, so dass die aussichtsreichsten System- und Speicherkonzepte in der Praxis erprobt und gezielt weiterentwickelt werden koennen. Mit Langzeit-Messprogrammen werden belastbare Werte der thermischen Leistung und Kosten der Anlagenkonzepte ermittelt und eine zuverlaessige Grundlage fuer die technisch-wirtschaftliche Bewertung geschaffen. (orig.)

  8. Electric power is not the same power. Why the energy transition can not succeed; Strom ist nicht gleich Strom. Warum die Energiewende nicht gelingen kann

    Energy Technology Data Exchange (ETDEWEB)

    Limburg, Michael; Mueller, Fred F.

    2015-07-01

    The energy transition - the conversion of our power supply to so-called ''Renewable Energy'' - will lead to disaster, economically as well as technically. Although the concept is not technically feasible, more than 500 billion Euros were spent for this purpose already. This money our economy will miss bitterly when it is needed it to go, sweep up the future shambles. Here explain two recognized experts why. ''The book, 'electric power is not the same power' pulled himself together again on a colossal effort. It dissects technically brilliant with the tools of logic, scientific reasoning a fatal mental aberration.''- Arnold Vaatz MP. [German] Die Energiewende - die Umstellung unserer Stromversorgung auf sogenannte ''Erneuerbare Energien'' - wird in eine Katastrophe fuehren, wirtschaftlich ebenso wie technisch. Obwohl das Konzept technisch nicht machbar ist, wurden hierfuer bereits mehr als 500 Milliarden Euro ausgegeben. Dieses Geld wird unserer Volkswirtschaft bitter fehlen, wenn sie darangehen muss, den kuenftigen Scherbenhaufen zusammenzukehren. Hier erklaeren zwei ausgewiesene Fachleute, warum. ''Das Buch 'Strom ist nicht gleich Strom' rafft sich noch einmal zu einer ungeheuren Kraftanstrengung auf. Es seziert handwerklich brillant mit den Mitteln der logischen, naturwissenschaftlichen Argumentation einen fatalen geistigen Irrweg.'' - Arnold Vaatz MdB.

  9. The World Optical Depth Research and Calibration Center (WORCC) quality assurance and quality control of GAW-PFR AOD measurements

    Science.gov (United States)

    Kazadzis, Stelios; Kouremeti, Natalia; Nyeki, Stephan; Gröbner, Julian; Wehrli, Christoph

    2018-02-01

    The World Optical Depth Research Calibration Center (WORCC) is a section within the World Radiation Center at Physikalisches-Meteorologisches Observatorium (PMOD/WRC), Davos, Switzerland, established after the recommendations of the World Meteorological Organization for calibration of aerosol optical depth (AOD)-related Sun photometers. WORCC is mandated to develop new methods for instrument calibration, to initiate homogenization activities among different AOD networks and to run a network (GAW-PFR) of Sun photometers. In this work we describe the calibration hierarchy and methods used under WORCC and the basic procedures, tests and processing techniques in order to ensure the quality assurance and quality control of the AOD-retrieved data.

  10. Kwaliteit van gemeentelijk groen buiten de bebouwde kom

    OpenAIRE

    Oosterbaan, A.; Hoogenboom, F.G.G.; Spijker, J.H.; Vries, de, E.A.

    2004-01-01

    Interactief met enkele gemeenten is een methodiek ontworpen om de kwaliteit van het gemeentelijk groen buiten de bebouwde kom in beeld te brengen. Gemeenten hebben behoefte om de kwaliteit van groen te bekijken op het niveau van landschap en element. De ontwikkeling van cultuurhistorische en ecologische waarde op landschapniveau kunnen worden afgemeten aan bestaande beleidsplannen. Daarnaast moeten in het veld het functioneren en de technische staat worden van de elementen worden beoordeeld. ...

  11. Collaborative Media Streaming

    OpenAIRE

    Kahmann, Verena

    2008-01-01

    Mit Hilfe der IP-Technologie erbrachte Multimedia-Dienste wie IPTV oder Video-on-Demand sind zur Zeit ein gefragtes Thema. Technisch werden solche Dienste unter dem Begriff "Streaming" eingeordnet. Ein Server sendet Mediendaten kontinuierlich an Empfänger, welche die Daten sofort weiterverarbeiten und anzeigen. Über einen Rückkanal hat der Kunde die Möglichkeit der Einflussnahme auf die Wiedergabe. Eine Weiterentwicklung dieser Streaming-Dienste ist die Möglichkeit, gemeinsam mit anderen dens...

  12. Modellierung modularer Materialfluss-Systeme mit Hilfe von künstlichen neuronalen Netzen

    OpenAIRE

    Markwardt, Ulf

    2004-01-01

    Materialfluss-Systeme für den Stückgut-Transport auf der Basis von Stetigförderern sind meist modular aufgebaut. Das Verhalten gleichartiger Materialfluss-Elemente unterscheidet sich durch technische Parameter (z.B. geometrische Größen) und durch unterschiedliche logistische Belastungen der Elemente im System. Durch die in der Arbeit getroffenen Modellannahmen werden für die Elemente nur lokale Steuerungsregeln zugelassen und für das System Blockierfreiheit vorausgesetzt. Das Verhalten eines ...

  13. Michael Polanyi: Patriarch of Chemical Dynamics and Tacit Knowing.

    Science.gov (United States)

    Herschbach, Dudley R

    2017-03-20

    Connecting Science and the Humanities was the title of the symposium on Michael Polanyi that took place at the Technische Universität Berlin (Technical University of Berlin) in October 2016. This essay, which appraises the scientific and philosophical contributions of Michael Polanyi, is based on the presentation given by Dr. Herschbach on this occasion. In the photograph: Polanyi in 1931. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Enterprise Portals und Enterprise Application Integration - Begriffsbestimmung und Integrationskonzeptionen

    OpenAIRE

    Schelp, Joachim; Winter, Robert

    2002-01-01

    Unter den Stichworten »Enterprise Portals« und »Enterprise Application Integration« werden neue Herausforderungen an die Applikationsarchitektur der Unternehmungen gestellt. Bei beiden spielt die Integration vorhandener und das Einfügen neuer Applikationen eine große Rolle. Beiden Themen ist gemein, dass sie die Diskussion bestimmter technischer Konzepte aus den vergangenen Jahren fortsetzen: Portale stellen das moderne Frontend dar, über das die verschiedenen E-Business-Konzepte umgesetzt we...

  15. Geometrische und stochastische Modelle zur Verarbeitung von 3D-Kameradaten am Beispiel menschlicher Bewegungsanalysen

    OpenAIRE

    Westfeld, Patrick

    2012-01-01

    Die dreidimensionale Erfassung der Form und Lage eines beliebigen Objekts durch die flexiblen Methoden und Verfahren der Photogrammetrie spielt für ein breites Spektrum technisch-industrieller und naturwissenschaftlicher Einsatzgebiete eine große Rolle. Die Anwendungsmöglichkeiten reichen von Messaufgaben im Automobil-, Maschinen- und Schiffbau über die Erstellung komplexer 3D-Modelle in Architektur, Archäologie und Denkmalpflege bis hin zu Bewegungsanalysen in Bereichen der Strömungsmesstech...

  16. De strijd om de richting van de Westerse cultuur

    OpenAIRE

    Schuurman, E.

    2010-01-01

    Herbert Marcuse is de belangrijkste vertegenwoordiger van de culturele revolutie van de twintigste eeuw. Hij vertegenwoordigt de weerstand in de Westerse cultuur tegen het wetenschappelijk-technisch ideaal van de Verlichting. Zijn vrijheidsideaal heeft niettemin dezelfde wortels. Sinds de Verlichting wordt de Westerse cultuur beheerst door de strijd tussen deze twee idealen. Om de strijd te verminderen en de spanning in de cultuur te laten afnemen, is een transformatie van de cultuur noodzake...

  17. Design of a liquid metal target loop for a high power spallation

    CERN Document Server

    Andreas Vetter (PSI)

    Diplomarbeit zur Erlangung des Grades Diplom-IngenieurTechnische Universität BerlinThis thesis shows the lay-out of the liquid metal loop, which is designed to evacuate 3.0 MW of thermal power. It describes the function and sizing of the piping and components. The thesis deals with the choice of the pump, the expansion tank/gas separator and the heat exchanger using water as cooling fluid as well as instrumentation.

  18. Technische analyse houtskeletbouw: aanzet, horizontale en verticale stabiliteit, funderingsvoordelen en EPB

    OpenAIRE

    Kilic, Oguz; Kilic, Cengizhan

    2014-01-01

    In drie delen wordt in deze thesis enerzijds de lezer meer informatie verschaft over de methodes en manieren van funderingsaanzet van houtskeletbouw en anderzijds ook een idee gegeven van de impact van het kleiner eigengewicht van deze constructie. Hiertoe worden in deel 1 de mogelijke manieren en materialen van het aanzetten van HSB elementen besproken. Dit wordt gedaan aan de hand van wrijvingsproeven, uittrekproeven en berekeningen. Ook wordt gecontroleerd of de bouwknopen EPB-aanvaard zij...

  19. A safer road environment for cyclists. Proefschrift Technische Universiteit Delft TUD.

    NARCIS (Netherlands)

    Schepers, P.

    2013-01-01

    This thesis focuses on the question of how the road environment (road design and network characteristics) affects road safety for cyclists through effects on risk and exposure to risk. In this thesis, the term ‘road design’ is used to denote the location level (e.g. intersection design) while the

  20. Begetting machinery II – Evolutionärer Algorithmus und technische Evolution

    Directory of Open Access Journals (Sweden)

    Rothenhäusler, Andie

    2011-10-01

    Full Text Available In the 1970s and 1980s two new approaches to an evolutionary explanation of technology emerged: While a new generation of sociobiologists increasingly started to view animal and human artifacts as an ,extended phenotype’ of humankind historians and sociologists of technology found in an evolutionary genesis of technology a third way between technological determinism and a social construction of technology. This evolution of technology seemed able to explain multi-causal coherences in the genesis of technology applicably by using allegedly simple rules.

  1. Energy conservation by technical means: the control systems matter.; Energiesparen durch technische Hilfsmittel: auf die Regelkreise kommt es an.

    Energy Technology Data Exchange (ETDEWEB)

    Benecke, J. [Verein Deutscher Ingenieure (VDI), Muenchen (Germany)

    2000-07-01

    The new German regulation on energy conservation in buildings (draft) offers certain flexibility for choosing the quality of the building envelope (thermal resistance and air tightness) and of the HV equipment (AC not considered) in order to balance and minimize the yearly heating-energy demand. Up to now, there was little consideration given to control systems which are able to assist the inhabitants in using heating and ventilation efficiently. The performance of such systems is being discussed. (orig.) [German] In Deutschland betraegt der Anteil der Raumheizenergie am Endenergieverbrauch rund 35%; ihr Anteil am Endenergieverbrauch der Haushalte und Kleinverbraucher betraegt rund 76%. Die Vorgaben der bisherigen Waermeschutzverordnungen und der geplanten Energieeinsparverordnung veranschaulichen das Energieeinsparpotential, das durch effizientere Energienutzung im Gebaeudebereich erschlossen werden kann. (orig.)

  2. Interlaboratory comparison of environmental relevant nuclides with spinach powder as sample medium; Vergleichspruefung mit Spinatpulver als Probenart fuer umweltrelevante Nuklide

    Energy Technology Data Exchange (ETDEWEB)

    Roos, N.; Tait, D. [Max Rubner-Institut, Kiel (Germany). Leitstelle fuer Boden, Bewuchs, Futtermittel und Nahrungsmittel pflanzlicher und tierischer Herkunft

    2014-01-20

    Spinach is cited as a representative medium for leafy vegetables in the Integrated Measurement and Information System for the surveillance of environmental radioactivity (IMIS) in Germany. Fresh spinach, however, is not suitable in interlaboratory comparisons on the determination of spiked radionuclides because of the difficulties in homogeneously distributing the radionuclides and attaining a known specific activity in the samples. In contrast, spinach powder is finely milled, so that homogeneous distribution and known specific activities of the nuclides are more readily achievable. For this interlaboratory comparison spinach powder was mixed with the pure beta emitter Sr-90 and the gamma-emitting nuclides I-131, Cs-134 and Cs-137. After homogenization samples were dispatched to 77 laboratories from Germany and other European countries (59 in Germany, 5 in Switzerland, 4 each in the UK and Austria, and one each in France, Italy, the Netherlands, Ireland and Luxembourg). In addition to the added nuclides participants had to determine the natural radionuclide K-40. The participants were instructed to use a fast method for the determination of dry matter (DM). To check the homogeneity of the nuclide distribution 14 samples of the labeled spinach powder were randomly selected and analyzed in the Coordinating Laboratory for the Surveillance of Radioactivity in the Environment of the Max Rubner-Institute (MRI). According to DIN 13528:2005 the samples showed sufficient homogeneity of the added nuclides. For the evaluation of the interlaboratory comparison the Physikalisch-Technische Bundesanstalt (PTB) determined reference values for the the specific activities (Bq per kg DM) of the gamma emitters. The values with the expanded uncertainties (k = 2) were as follows: I-131: 181 ± 6 Bq/kg; Cs-134: 34.4 ± 1.1 Bq/kg; Cs-137: 11.1 ± 0.4 Bq/kg; K-40: 1240 ± 40 Bq/kg. Since a reference value of the PTB for the specific activity of Sr-90 was not available the general average

  3. Development and characterization of magnetic iron oxide nanoparticles with a cisplatin-bearing polymer coating for targeted drug delivery

    Directory of Open Access Journals (Sweden)

    Unterweger H

    2014-08-01

    Full Text Available Harald Unterweger,1 Rainer Tietze,1 Christina Janko,1 Jan Zaloga,1 Stefan Lyer,1 Stephan Dürr,1 Nicola Taccardi,2 Ourania-Menti Goudouri,3 Alexander Hoppe,3 Dietmar Eberbeck,4 Dirk W Schubert,5 Aldo R Boccaccini,3 Christoph Alexiou1 1ENT Department, Section of Experimental Oncology and Nanomedicine (SEON, Else Kroener-Fresenius-Stiftung-Professorship, University Hospital Erlangen, 2Chair of Chemical Engineering I (Reaction Engineering, 3Institute of Biomaterials, Department of Materials Science and Engineering, University Erlangen-Nuremberg, Erlangen, 4Physikalisch-Technische Bundesanstalt, Berlin, 5Institute of Polymer Materials, Department of Materials Science and Engineering, University Erlangen-Nuremberg, Erlangen, Germany Abstract: A highly selective and efficient cancer therapy can be achieved using magnetically directed superparamagnetic iron oxide nanoparticles (SPIONs bearing a sufficient amount of the therapeutic agent. In this project, SPIONs with a dextran and cisplatin-bearing hyaluronic acid coating were successfully synthesized as a novel cisplatin drug delivery system. Transmission electron microscopy images as well as X-ray diffraction analysis showed that the individual magnetite particles were around 4.5 nm in size and monocrystalline. The small crystallite sizes led to the superparamagnetic behavior of the particles, which was exemplified in their magnetization curves, acquired using superconducting quantum interference device measurements. Hyaluronic acid was bound to the initially dextran-coated SPIONs by esterification. The resulting amide bond linkage was verified using Fourier transform infrared spectroscopy. The additional polymer layer increased the vehicle size from 22 nm to 56 nm, with a hyaluronic acid to dextran to magnetite weight ratio of 51:29:20. A maximum payload of 330 µg cisplatin/mL nanoparticle suspension was achieved, thus the particle size was further increased to around 77 nm with a zeta

  4. Digitalisierung in der Energiewirtschaft - empirische Untersuchung und Wertschöpfungskette

    Science.gov (United States)

    Dell, Timo

    Die Energiewirtschaft nutzt seit je her digitale Strukturen zur Umsetzung ihrer Prozesse. Durch den (neuen) verabschiedeten politischen Ordnungsrahmen - dem Gesetz zur Digitalisierung der Energiewende - und durch die rasante Fortentwicklung technologischer Strukturen ergeben sich jedoch die Wertschöpfungsstufen erweiternde, diversifizierende und innovative Möglichkeiten für Energieversorger (EVU) Geschäftsfelder auszubauen bzw. neue zu erschließen. Dabei ist die digitale (R)Evolution keine rein technische Umsetzung, sondern insbesondere auch eine unternehmensinterne, strategische und intern-kulturelle Herausforderung.

  5. Der "Mere-Exposure-Effekt" in der Mensch-Technik-Interaktion und seine Auswirkungen auf das Nutzererleben

    OpenAIRE

    Vogel, Marlene

    2016-01-01

    Der Umgang mit interaktiven Schnittstellen technischer Geräte gehört heute zum Alltag vieler Menschen. Diese Schnittstellen werden durch die zunehmende Funktionalität der Geräte komplexer. Beispielsweise sind die heutigen Mobiltelefone, sogenannte Smartphones, mit ihrer unterstützenden und umfangreichen Funktionalität nicht mehr aus dem Leben vieler Menschen wegzudenken. Dabei ist es nicht nur der effiziente Umgang mit der Technik, der u. a. für die Kaufentscheidung eine Bedeutung hat. Vielme...

  6. Zusammenarbeit, Sichtbarkeit, Einbindung und Effizienz : Fallstudie zur Verwendung interaktiver Whiteboards an einem Gymnasium in Deutschland

    OpenAIRE

    Passey, Donald

    2017-01-01

    Dieser Bericht bietet einen Überblick über die Ergebnisse einer einjährigen Studie, die an einer deutschen Schule (Gymnasium) in einer Stadt in Nordrhein-Westfalen (NRW) durchgeführt wurde. Während ein Forschungsschwerpunkt auf dem Thema „Zusammenarbeit“ lag, erforderte auch die Planung und Durchführung der Studie gemeinsame Anstrengungen: Die Schule hatte ihren Anteil an der Implementation interaktiver Whiteboards; SMART Technologies stellte Ausrüstung und technische Unterstützung zur Verfüg...

  7. Mechanical-biological waste treatment with thermal processing of partial fractions; Mechanisch-biologische Restabfallbehandlung unter Einbindung thermischer Verfahren fuer Teilfraktionen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    Technologies for mechanical-biological treatment of waste in the Land of Hessen were compared including thermal processes like combustion and gasification. The new and more rigid limiting values specified in the Technical Guide for Municipal Waste Treatment (Technische Anleitung Siedlungsabfall - TASI) get a special mention. [Deutsch] Verschiedene Technologien der mechanisch-biologischen Restabfallbehandlung im Raum Hessen wurden unter Einbezug thermischer Verfahren (Verbrennung, Vergasung) miteinander verglichen. Dabei wurden besonders auf die verschaerften Grenzwerte der Technischen Anleitung Siedlungsabfall (TASI) eingegangen. (ABI)

  8. Talk | The impact of fundamental Physics on Medicine by Ugo Amaldi | 10 April

    CERN Multimedia

    2014-01-01

    The impact of fundamental Physics on Medicine, by Ugo Amaldi, TERA Foundation and Technische Universität München.   Thursday 10 April 2014, at 7.30 p.m. Globe of Science and Innovation Route de Meyrin, 1211 Genève Talk in English with French translation. Abstract: It is clear to anybody who visits a hospital that Physics applications are everywhere. Medical doctors use Physics when they measure blood pressure, when they perform an ultrasound scan to determine the sex of an unborn child, when they take a radiography or a CT scan. Fundamental physics, which aims at understanding how particles and forces act in the subatomic world and are organized to form everything we observe around us, has numerous medical applications.  Everything started in 1895 with the discovery of X-rays by Röntgen, who was using the best particle accelerator of the time. In the lecture the theme of the title will be presented by following the 120 years long story of par...

  9. Closing remarks at the symposium in honour of Daniel Bellus. Pharmacenter, University of Basel, February 6, 2009.

    Science.gov (United States)

    Ganter, Camille

    2010-01-01

    In the Closing Remarks at the Symposium on 'Frontiers in Bioorganic Chemistry' (Friday, February 6, 2009, Pharmacenter, University of Basel) in honour of Daniel Bellus, his arrival in Zürich in fall 1967 and especially his postdoctoral work at the Laboratorium für Organische Chemie at the Eidgenössische Technische Hochschule (ETH) in Zürich throughout the year 1967/68 were mentioned. In his most remarkable paper (published in 1969 in Helv. Chim. Acta), the photochemistry of the alpha,beta-unsaturated cyclohexenones O-acetyl-testosterone and 10-methy-delta1,9-octalon-(2) is described in detail. Change of solvent leads to lowering or increasing of the n,pi*- and (pi,pi*)-triplet energies, resulting in a crossing of the two energy levels. Personal remarks on Daniel Bellus and warmest thanks to him, to Profs. Beat Ernst and Bernd Giese (the organizers of the symposium) and to all the speakers concluded this most special event.

  10. Measuring technology using holography and interferometry. HOLOMETEC. Pamphlet for the concluding presentation; Holografisch-interferometrische Messtechnik. HOLOMETEC. Broschuere zur Abschlusspraesentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The German Federal Ministry of Education, Science, Research and Technology (BMBF) provided funds to the focal item of research, `Laser science and laser technology`, for the development of measuring and testing methods based on holography and interferometry, for applications such as quality assurance and experimental stress analysis. The main objective of research activities with collaborators from science and industry was to develop the holographic and interferometric techniques to a contactless measuring technology fit for applications in industry. The BMBF contributed for the R and D programme financial support amounting to DM 6.6 million, in a total budget of DM 9.6 million. The concluding presentation was intended to summarize and demonstrate the work performed and results achieved. (orig./MM) [Deutsch] Das Bundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie foerderte im Foerderschwerpunkt ``Laserforschung und Lasertechnik`` die Erarbeitung von Verfahrensgrundlagen zur holografisch-interferometrischen Messtechnik fuer die Qualitaetssicherung und experimentelle Spannungsanalyse. Wesentliches Ziel der Forschungsarbeiten, an denen sich Partner aus Wissenschaft und Wirtschaft beteiligten, war es, die holografisch-interferometrische Messtechnik als beruehrungsloses Mess- und Pruefverfahren fuer die industrielle Anwendung tauglich zu machen. Das BMBF unterstuetzte die F und E-Arbeiten mit insgesamt 6.6 Mio DM bei einem Gesamtaufwand von 9.6 Mio DM. Mit der Abschlusspraesentation sollen der Fachoeffentlichkeit die nun vorliegenden Ergebnisse der Forschungsarbeiten vorgestellt werden. (orig./MM)

  11. Einstein und Heisenberg Begründer der modernen Physik

    CERN Document Server

    Kleinknecht, Konrad

    2017-01-01

    Dieses Buch erzählt die spannende Geschichte der großartigen Entdeckungen des 20. Jahrhunderts: der Einsteinschen Relativitätstheorie und der Heisenbergschen Quantenmechanik. Diese Entdeckungen legten die Grundlagen der heutigen Physik, ohne die unsere digitalisierte Welt der Computer, Satelliten und neuen Werkstoffe nicht möglich wäre. Konrad Kleinknecht versteht es, komplizierte physikalische Zusammenhänge verständlich zu schildern und verbindet die Geschichte der modernen Physik mit den Lebensläufen der beiden außergewöhnlichen Physiker. Er beschreibt in dieser Doppelbiographie die Gemeinsamkeiten und Gegensätze der beiden Koryphäen und zeigt, wie ihr Wirken das 20. Jahrhundert zum Jahrhundert der Physik formte.

  12. Update in breast MRT. Standards and quality management; Update in der Mamma-MRT-Technik. Untersuchungsstandards und Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Claudia [Kantonsspital Luzern, Lucerne (Switzerland). Inst. fuer Radiologie

    2013-06-15

    Meanwhile breast MRI has emerged to an important tool for breast diagnostics, with a broad spectrum of technical requirements and interpretation guidelines. The use of breast MRI is reasonable and helpful, provided that an appropriate application and optimal technical conditions are fulfilled, otherwise unnecessary follow-up examinations or biopsies might be initiated. This article gives an overview about planning and performing the examination, describes the physical background for optimal acquisition protocols, gives support for post-processing and image interpretation and also refers to possible misinterpretations. (orig.)

  13. Elektrische Energieversorgung

    Science.gov (United States)

    Schulz, Detlef

    Nur mit einer zuverlässigen und wirtschaftlichen elektrischen Energieversorgung ist eine nachhaltige gesellschaftliche Entwicklung von Industrienationen möglich. Gleichzeitig muss diese selbst so nachhaltig, d. h. umweltverträglich gestaltet werden, dass auch zukünftige Generationen nicht in ihrer Entfaltung behindert werden. Eine versorgungssichere, wirtschaftliche und umweltverträgliche Energiebereitstellung ergibt sich nicht zwingend allein aus einer technisch evolutionären Entwicklung und ist auch bis heute nicht ausschließlich nur mit einer der bekannten Wandlungstechnologien nachweislich realisierbar.

  14. Emergency Power Supply Control. The weakest link or the strongest trump; Noodstroombesturing. De zwakste schakel of de sterkste troef

    Energy Technology Data Exchange (ETDEWEB)

    Van Deursen, R.; Jansen, G. [Royal Haskoning Nederland, Nijmegen (Netherlands)

    2008-12-15

    This article addresses reliable electrical energy supply in health care. Beside technical aspects, operational aspects also play an important role in this sector in the selection for emergency power management. Will tailor-made solutions be sought or standard management concepts? [mk]. [Dutch] In dit artikel aandacht voor een betrouwbare elektrische energievoorziening in de gezondheidszorg. Naast technische aspecten spelen in deze sector ook de operationele aspecten een belangrijke rol in de selectie voor noodstroombesturing. Wordt het maatwerk of een standaard besturingsconcept.

  15. Bewertung von Fahrzeuggeräuschen

    Science.gov (United States)

    Genuit, Klaus; Schulte-Fortkamp, Brigitte; Fiebig, André; Haverkamp, Michael

    Bei der Wahrnehmung und Beurteilung eines Automobils sind unzählige Merkmale und Eigenschaften von Bedeutung. Dabei können Merkmale objektiv-technisch beschrieben werden, wie Angaben zur Motorisierung, Höchstgeschwindigkeit, Drehmoment, zulässige Zuladung, Verbrauch usw. Daneben sind weitere Eigenschaften von Bedeutung, die sich einer einfachen objektiv-technischen Beschreibung entziehen. Hier sind Begriffe zu nennen, wie Sicherheit, allgemeine Qualitätsanmutung, Design, Ergonomie, Komfort, Haptik, Fahrdynamik, Zuverlässigkeit, die deutlich schwieriger objektiv erfassbar und beschreibbar sind (Abb. 4.1).

  16. Eine praktische Anwendung von CMC-Flächen in der Bionik

    OpenAIRE

    Apeltauer, Christian

    2011-01-01

    Die vorliegende Arbeit beschäftigt sich mit den theoretischen Grundlagen für die Entwicklung von Oberflächen, die unter Wasser möglichst lange eine Luftschicht an sich halten können. Ein natürliches Vorbild für solche Oberflächen ist die Pflanze Salvinia molesta; technisch interessieren solche Oberflächen zur Verringerung des Wasserwiderstandes von Schiffen und als Schutz vor Besiedlung durch Wasserorganismen. Wichtigste Gleichung bei der Entwicklung solcher Oberflächen ist...

  17. Prognostic factors in glioblastoma multiforme. 10 years experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Hulshof, M C.C.M.; Schimmel, E C; Gonzalez, D G [Amsterdam Univ. (Netherlands). Dept. of Radiotherapy; Koot, R W; Bosch, D A [Amsterdam Univ. (Netherlands). Dept. of Neurosurgery; Dekker, F [Amsterdam Univ. (Netherlands). Dept. of Epidemiology

    2001-06-01

    Background: To analyze prognostic factors in patients with a glioblastoma multiforme treated in an academic institute over the last 10 years. Patients and method: From 1988 to 1998, 198 patients with pathologically confirmed glioblastoma multiforme were analyzed. Five radiation schedules were used mainly based on pretreatment selection criteria: 1. 60 Gy in 30 fractions followed by an interstitial iridium-192 (Ir-192) boost for selected patients with a good performance and a small circumscribed tumor, 2. 66 Gy in 33 fractions for good performance patients, 3. 40 Gy in eight fractions or 4. 28 Gy in four fractions for poor prognostic patients and 5. no irradiation. Results: Median survival was 16 months, 7 months, 5.6 months, 6.6 months and 1.8 months for the groups treated with Ir-192, 66 Gy, 40 Gy, 28 Gy and the group without treatment, respectively. No significant improvement in survival was encountered over the last 10 years. At multivariate analysis patients treated with a hypofractionated scheme showed a similar survival probability and duration of palliative effect compared to the conventionally fractionated group. The poor prognostic groups receiving radiotherapy had a highly significant better survival compared to the no-treatment group. Patients treated with an Ir-192 boost had a better median survival compared to a historical group matched on selection criteria but without boost treatment (16 vs 9.7 months, n.s.). However, survival at 2 years was similar. Analysis on pretreatment characteristics at multivariate analysis revealed age, neurological performance, addition of radiotherapy, total resection, tumor size post surgery and deterioration before start of radiotherapy (borderline) as significant prognostic factors for survival. Conclusion: Despite technical developments in surgery and radiotherapy over the last 10 years, survival of patients with a glioblastoma multiforme has not improved in our institution. The analysis of prognostic factors

  18. Effects of a complex intervention on fall risk in the general practitioner setting: a cluster randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Freiberger E

    2013-08-01

    Full Text Available Ellen Freiberger,1 Wolfgang A Blank,2 Johannes Salb,1 Barbara Geilhof,3 Christian Hentschke,1 Peter Landendoerfer,2 Martin Halle,3 Monika Siegrist31Institute of Sport Science and Sport Universität Erlangen-Nürnberg, Nuremberg, Germany; 2Institute of General Practice, Technische Universität München, Munich, Germany; 3Department of Prevention, Rehabilitation and Sports Medicine, Technische Universität München, Munich, GermanyPurpose: To study the feasibility of first, reaching functionally declined, but still independent older persons at risk of falls through their general practitioner (GP and second, to reduce their physiological and psychological fall risk factors with a complex exercise intervention. We investigated the effects of a 16-week exercise intervention on physiological (function, strength, and balance and psychological (fear of falling outcomes in community-dwelling older persons in comparison with usual care. In addition, we obtained data on adherence of the participants to the exercise program.Methods: Tests on physical and psychological fall risk were conducted at study inclusion, and after the 16-week intervention period in the GP office setting. The 16-week intervention included progressive and challenging balance, gait, and strength exercise as well as changes to behavioral aspects. To account for the hierarchical structure in the chosen study design, with patients nested in GPs and measurements nested in patients, a three-level linear mixed effects model was determined for analysis.Results: In total, 33 GPs recruited 378 participants (75.4% females. The mean age of the participants was 78.1 years (standard deviation 5.9 years. Patients in the intervention group showed an improvement in the Timed-Up-and-Go-test (TUG that was 1.5 seconds greater than that showed by the control group, equivalent to a small to moderate effect. For balance, a relative improvement of 0.8 seconds was accomplished, and anxiety about falls was

  19. Technical bio-oils. Fundamentals - products - framework conditions; Technische Biooele. Grundlagen - Produkte - Rahmenbedingungen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-03-27

    The Fachagentur Nachwachsende Rohstoffe e.V. (Guelzow-Pruezen, Federal Republic of Germany) and the Federal Ministry of Food, Agriculture and Consumer Protection (Bonn, Federal Republic of Germany) report on technical bio-oils. The contribution under consideration consists of the following chapters: Fundamentals, technical properties, applications, environmental aspects, legal framework conditions, funding measures; market of biological lubricants, economic operation with biological lubricants.

  20. Biochar. Production and technical fields of application; Biokohle. Erzeugung und technische Einsatzmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Quicker, Peter; Schulten, Marc [RWTH Aachen (Germany). Lehr- und Forschungsgebiet Technologie der Energierohstoffe TEER

    2012-09-15

    Although it is a familiar subject, biochar is highly topical. The reasons are climate protection measures and the security of resources. Both the energy-intensive primary industries, such as steel, cement- and lime plants, as well as the operators of fossil-fueled power plants, particularly coal-fired power stations, have a fundamental and economically motivated interest in climate-neutral and competitively priced energy resources. For economical causes and in relevance to the climate, the focus of biochar production should be on the use of biogenic waste material. In principle, two different methods are applied to produce biochar. One is through pyrolysis, meaning heating and devolatilization of the material under the exclusion of air, and the other one is through hydrothermal treatment of biomasses in aqueous phase under high pressure and elevated temperatures. Basically, biochar with high carbon content and a low amount of volatile matter is suitable for almost every industrial process, in which coal or coke are used as reducing agents, e.g. metallurgical processes, such as iron and steel production. In order to use biochar as a fuel, a lower level of quality is sufficient. In this case, the main aim of the thermal treatment is to increase the energy density of biomass.

  1. The contribution of wind energy to electric power generation; Der Beitrag der Windenergie zur Stromerzeugung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    The conference discussed the following five subjects: (1) Status and perspectives of wind power in Germany and Japan; (2) Grid connection of wind power systems; (3) Wind power and electric power supply; (4) Future fields of application, technical perspectives; (5) Panel discussion. [German] Der Tagungsband beinhaltet Beitraege in fuenf Bloecken, die die folgenden Ueberschriften haben: (1) Stand und Perspektiven der Windenergienutzung in Deutschland und Japan; (2) Netzintegration von Windenergieanlagen; (3) Windenergie in der elektrischen Energieversorgung; (4) zukuenftige Anwendungsfelder, technische Perspektiven sowie (5) Paneldiskussion. (AKF)

  2. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  3. 2003-2004 ACADEMIC TRAINING PROGRAMME: H. QUACK

    CERN Multimedia

    Françoise Benz

    2004-01-01

    ACADEMIC TRAINING Françoise Benz tel. 73127 academic.training@cern.ch LECTURE SERIES 8 and 12 March, from 11.00-12.00 hrs Main Auditorium 9 March, from 11.00-12.00 hrs TH Auditorium* 11 March, from 10.00-12.00 hrs** Main Auditorium Introduction to Cryogenic Engineering H. QUACK, Technische Univ. Dresden, D • Properties of materials • History of cryogenics • Refrigeration processes and machines • Cooling methods • Applications of cryogenics * Please note unusual place. ** Please note unusual time.

  4. Technical analysis of a 400 W{sub p} solar Stirling plant; Technische Analyse einer 400 W{sub p} Solar-Stirling-Anlage

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Reinhard; Rackwitz, Axel [Hochschule fuer Technik, Wirtschaft und Kultur Leipzig (HTWK), Markkleeberg (DE). Fakultaet Maschinenbau und Energietechnik (Montenegro)

    2012-07-01

    It is advisable to analyse different alternatives of the generation and supply of electrical energy and thermoelectricity with renewable forms of energy, because the demand of fuels (e.g. coal and oil) and the energy costs rise continuously. Technical optimization and cost-effectiveness of the different alternatives are the most important points of tests. This was the reason why at the Department of Mechanical and Energy Engineering of the Leipzig University of Applied Science a test ground ''renewable forms of energy'' has been built up step by step for thirteen years including two photovoltaic systems with different tracking systems, two wind-mills, an air-water-heat-pump and a dish-stirling-system. (orig.)

  5. Ecobalances of technical options for the supply and utilization of bioenergy; Oekobilanzen technischer Optionen zur Bioenergiebereitstellung und -nutzung

    Energy Technology Data Exchange (ETDEWEB)

    Dunkelberg, Elisa; Aretz, Astrid

    2013-05-15

    In Germany bioenergy production and consumption are promoted and encouraged by means of the Renewable Energy Law, which has as its objectives transforming the energy system and preventing climate change. In recent years several forms of bioenergy have been criticized as leading to ecological and socioeconomic risks. This study presents life cycle assessments (LCA) for existing bioenergy processes. The LCAs were conducted as a part of the Project ''Renewable Energy Regions: Socio-Ecology of Self-Sufficiency''; the objective was to assess the ecological impact of the selected bioenergy processes in order to calculate the overall ecological impact of existing bioenergy plants. The results prove that the usage of agricultural biomass such as corn and wheat for biogas production leads to negative ecological impacts such as eutrophication and acidification. If greenhouse gas emissions from land-use change are included, the net effect in comparison to the usage of fossil energies will only be small or even negative; however, when residues such as manure or materials from landscape management are used as substrates for biogas production they lead to several positive ecological impacts. Residual forest wood or wood from short-rotation coppices used in co-generation show the highest greenhouse gas reduction potential among the investigated processes. It must, however, be assumed that the potential of residual forest wood in Germany is already largely being tapped. Regions that have made bioenergy a priority thus should limit the usage of agricultural biomass for energy production to specific crops such as short-rotation coppices and floral and herbaceous perennials. Additionally, future challenges will require strategies to improve cascade utilization and gathering and efficient usage of residues.

  6. Single atom anisotropic magnetoresistance on a topological insulator surface

    KAUST Repository

    Narayan, Awadhesh

    2015-03-12

    © 2015 IOP Publishing Ltd and Deutsche Physikalische Gesellschaft. We demonstrate single atom anisotropic magnetoresistance on the surface of a topological insulator, arising from the interplay between the helical spin-momentum-locked surface electronic structure and the hybridization of the magnetic adatom states. Our first-principles quantum transport calculations based on density functional theory for Mn on Bi2Se3 elucidate the underlying mechanism. We complement our findings with a two dimensional model valid for both single adatoms and magnetic clusters, which leads to a proposed device setup for experimental realization. Our results provide an explanation for the conflicting scattering experiments on magnetic adatoms on topological insulator surfaces, and reveal the real space spin texture around the magnetic impurity.

  7. Advances in Solid State Physics

    CERN Document Server

    Haug, Rolf

    2007-01-01

    The present volume 46 of Advances in Solid State Physics contains the written versions of selected invited lectures from the spring meeting of the Arbeitskreis Festkörperphysik of the Deutsche Physikalische Gesellschaft which was held from 27 to 31 March 2006 in Dresden, Germany. Many topical talks given at the numerous symposia are included. Most of these were organized collaboratively by several of the divisions of the Arbeitskreis. The topis range from zero-dimensional physics in quantum dots, molecules and nanoparticles over one-dimensional physics in nanowires and 1d systems to more applied subjects like optoelectronics and materials science in thin films. The contributions span the whole width of solid-state physics from truly basic science to applications.

  8. What you can realize with bindled energy; Wat je met gebundelde energie kunt bereiken

    Energy Technology Data Exchange (ETDEWEB)

    Priester, J. [Yacht, Randstad, Diemen (Netherlands)

    2011-04-15

    Building Brains has been set up by TNO as a cooperative and started September 21, 2009. The aim of the project was to answer the question how the energy consumption in the Netherlands can be reduced by 50% up to 2030 or how the built environment can be made energy-neutral. This issue of the magazine is dedicated to Building Brains project. Within the Building Brains consortium the group Smart Energy has developed technical solutions for energy-neutral buildings. The collaboration between the companies was far from easy but has produced interesting results and insights. Energy neutral buildings are not only about saving energy. Comfort, costs and use of sustainable energy sources is just as important. An effort is made in smart solutions for building design, indoor-climate, lighting, electrical energy and user interface. Technical automation is a contribution to human centred solutions. [Dutch] Building Brains is een door TNO opgezet samenwerkingsproject dat op 21 september 2009 van start ging. Het doel van het project is antwoord te geven op de vraag hoe tot 2030 het energiegebruik in Nederland kan worden gehalveerd of hoe de gebouwde omgeving energieneutraal kan worden gemaakt. Deze aflevering van het tijdschrift TVVL is vrijwel geheel gewijd aan het Building Brains project. Binnen Building Brains heeft de groep Smart Energy gewerkt aan technische oplossingen voor energieneutrale gebouwen. Er is gekeken naar slimme oplossingen voor gebouwontwerp, binnenklimaat, verlichting, elektrische energie en de gebruikersinterface. Technische automatisering draagt bij aan oplossingen waarin de mens centraal staat.

  9. Economic and technical aspects the decarbonisation of the heat sector; Wirtschaftliche und technische Aspekte der Dekarbonisierung des Waermesektors

    Energy Technology Data Exchange (ETDEWEB)

    Rohrig, Kurt; Hoffmann, Clemens; Gerhardt, Norman [Fraunhofer IWES, Kassel (Germany); Schmidt, Dietrich; Schumacher, Patrick [Fraunhofer IBP, Stuttgart (Germany); Henning, Hans Martin; Palzer, Andreas [Fraunhofer ISE, Freiburg (Germany); Lechtenboehmer, Stefan [Wuppertal Institut fuer Klima, Umwelt, Energie GmbH, Wuppertal (Germany)

    2016-05-15

    The transformation of the energy system to a de-carbonized energy supply requires a coordinated interaction between the sectors electricity, heat and transport. Thereby, the coupling of the electricity sector with the heating sector is one of the key measures in the transformation. The inclusion of wind and solar energy in the grid can be optimized by exact feed in forecasts, the coupling to the heat sector by means of heat pumps and power-to-heat (heater) allows more flexibilisation of the demand side. This interaction is made possible by intelligent solutions of systems engineering and power management. The development of appropriate incentives, market mechanisms and business models is also required, to make this coupling also economic successful. The contribution present die 80% scenario for the year 2050 created in the research project ''Interaction RES electricity, heat and transport'' and gives examples of future requirements and developments on this topic. [German] Die Transformation des Energieversorgungssystems zu einer de-karbonisierten Energiebereitstellung bedingt ein koordiniertes Zusammenspiel der Sektoren Strom, Waerme und Verkehr. Dabei ist die Kopplung des Stromsektors mit dem Waermesektor eine der entscheidenden Massnahmen bei der Transformation. Die Aufnahme von Wind- und Sonnenenergie in das Netz kann durch genaue Einspeiseprognosen optimiert werden, die Kopplung zum Waermesektor mittels Waermepumpen und Power-to-Heat (Heizstab) ermoeglicht die weitere Flexibilisierung der Nachfrageseite. Diese Interaktion wird durch intelligente Loesungen der Systemtechnik fuer das Energie- und Netzmanagement ermoeglicht. Die Entwicklung von entsprechenden Anreizsystemen, Marktmechanismen und Geschaeftsmodellen ist ebenfalls erforderlich, um diese Kopplung auch wirtschaftlich erfolgreich zu gestalten. Der Beitrag stellt das im Forschungsvorhaben ''Interaktion EE-Strom, Waerme und Verkehr'' erstellte 80 %-Szenario fuer das

  10. Investigations of the applicability of a model-supported friction coefficient prediction model in a moving vehicle; Untersuchungen zum Einsatz eines modellunterstuetzten Reibwertvorhersagemodells im fahrenden Fahrzeug

    Energy Technology Data Exchange (ETDEWEB)

    Klempau, F. [TU Darmstadt, Fachgebiet Fahrzeugtechnik (Germany)

    2000-07-01

    In recent years driving-stability- and driver-assistance systems have become more and more common in new cars. Along with this development there is a growing demand for a system predicting the actual friction potential in the tyre contact patch. Within the European research project VERT (VEhicle Road Tyre Interaction) a big number of friction measurements were carried out to define the main influencing parameters of the tyre-road-friction-process. With the help of empirical and physical models it was possible to describe the effect of these main influencing parameters on friction values. The aim of the research work in this project is to implement these models in driving simulations as well as to consider the feasibility to implement them into real cars. This paper presents the possibilities developing a friction prediction model for implementation in a moving vehicle. (orig.) [German] U.a. wegen der zunehmenden Verbreitung von Fahrdynamik- und Fahrerassistenz - Systemen wird der Wunsch nach Kenntnis des Reibwertpotentials zwischen Reifen und Fahrbahn immer dringender. Zur Bestimmung der Einfluesse auf den Reibwert wurden im Rahmen des europaeischen Forschungsprojekts VERT, dessen Partner fzd ist, eine Vielzahl von Messungen durchgefuehrt. Ihre Auswertung ermoeglichte die Bestimmung von Haupteinflussgroessen und die Beschreibung ihrer Auswirkungen auf den Reibwert mittels empirischer und physikalischer (orig.)

  11. Quality assurance and management in radiation protection - burden and benefit; Qualitaetssicherung und -management im Strahlenschutz - Last und Nutzen

    Energy Technology Data Exchange (ETDEWEB)

    Baehrle, H.G.; Butterweck, G.; Habegger, R.; Schuler, C.; Wyser, U. [Paul Scherrer Inst., Villigen PSI (CH). Abt. Strahlenschutz und Sicherheit (ASI); Beck, T. [Bundesamt fuer Strahlenschutz, Berlin (Germany). Inst. fuer Angewandten Strahlenschutz; Buchholz, W. [Bundesamt fuer Strahlenschutz, Oberschleissheim (Germany). AG-SG 2.4 - Inkorporationsueberwachung; Kuehne, J.; Tesch, J. [Landesamt fuer Umwelt, Naturschutz und Geologie Mecklenburg-Vorpommern, Stralsund (Germany). Abt. Umweltanalytik und Strahlenschutz; Valbuena, A. [DAP Deutsches Akkreditierungssystem Pruefwesen GmbH, Berlin (Germany)

    2008-07-01

    Measurements of radiation for the purpose of Radiation Protection and Health Physics demand a high degree of quality and accuracy. Selected topics of quality management and control are presented. They vary from practical aspects of analytical quality control, from traceability and uncertainty of measurement results to quality of intralaboratory communication. Changes in the German system of accreditation due to European harmonization are also presented. Certification and accreditation of testing laboratories are being increasingly expected and have already been laid down by certain federal regulations. (orig.)

  12. Radiological information systems: improvements in service, economy, and quality control?; Radiologische Informationssysteme: Verbesserung von Leistungserfassung, Wirtschaftlichkeit und Qualitaetssicherung?

    Energy Technology Data Exchange (ETDEWEB)

    Gross-Fengels, W. [Abt. fuer Klinische Radiologie, AK Harburg (Germany); Weber, M. [Abt. fuer Klinische Radiologie, AK Harburg (Germany)

    1997-03-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient`s history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [Deutsch] Radiologische Informationssysteme fuehren ueber komplette Leistungserfassungen und standardisierte Abrechnungsverfahren eindeutig zu einer Ergebnisverbesserung. Sie stellen die Voraussetzungen fuer den Aufbau erweiterter Netzstrukturen dar und erlauben Quervergleiche mit aehnlichen Institutionen. Die Qualitaet der Patientenversorgung laesst sich verbessern, da z.B. die `Produktionszeit` von der Anforderung bis hin zur Befundausgabe kuerzer wird. Der Zugriff zu Patienten- und Befunddaten ist unmittelbar von mehreren Stellen aus moeglich. Vorbefunde sind sofort einsehbar. Die Patientenhistorie ist jederzeit fuer autorisierte Anwender verfuegbar. Die exakte Reproduzierbarkeit und Zuordnung der Leistungen fuehrt zu einer hohen Transparenz. Durch die Informationen, die ueber das RIS zu erhalten sind, koennen rasche Anpassungsprozesse vorgenommen werden. Die Anlagen unterstuetzen den Anwender, den Anforderungen der GSG nachzukommen. Die vorgenannten Zusammenhaenge verdeutlichen, dass diese radiologischen EDV-Anlagen bei Aerzten, MTAs und Verwaltungsmitarbeitern eine hohe Akzeptanz aufweisen und fuer die angestrebten Problemloesungen ein unverzichtbares Hilfsmittel darstellen. (orig.)

  13. Altheim geothermal plant. Power generation by means of an ORC turbogenerator; Geothermieanlagen Altheim. Stromerzeugung mittels Organic-Rankine-Cycle Turbogenerator

    Energy Technology Data Exchange (ETDEWEB)

    Pernecker, G [Marktgemeindeamt Altheim (Austria)

    1997-12-01

    The report describes the project of the Austrian market town of Altheim to generate electricity by means of an ORC turbogenerator using low-temperature thermal water. The project is to improve the technical and economic situation of the existing industrial-scale geothermal project. (orig.) [Deutsch] Der Bericht beschreibt das Vorhaben der Marktgemeinde Altheim in Oberoesterreich, Strom mittels eines Organic-Rankine-Cycle-Turbogenerators unter Verwendung niedrig temperierten Thermalwassers zu produzieren. Ziel bzw. der Zweck des Projektes ist es, die technische und wirtschaftliche Situation der bestehenden Grossthermieanlage zu verbessern. (orig.)

  14. A simulation-powered approach to ventilation, lighting and shading systems control

    Energy Technology Data Exchange (ETDEWEB)

    Schuss, Matthias; Proeglhoef, Claus; Orehounig, Kristina; Mahdavi, Ardeshir [Department of Building Physics and Building Ecology, Vienna University of Technology (Austria)

    2010-12-15

    This paper reports on ongoing work toward implementing a predictive control approach for buildings systems for ventilation, lighting, and shading. The main objective of this method is the optimized control of multiple devices toward usage of passive cooling and natural lighting. In this way, control options (various opening positions of windows, shades, etc.) are generated and computationally assessed using a combination of option space navigation via genetic algorithms and numeric simulation. (Copyright copyright 2010 Ernst and Sohn Verlag fuer Architektur und technische Wissenschaften GmbH and Co. KG, Berlin)

  15. Fuels and Combustion Technology for Advanced Aircraft Engines (Les Propergols et les Systemes de Combustion pour les Moteurs d’Aeronefs)

    Science.gov (United States)

    1993-09-01

    Fachgebiet Flugantriebe Ingenieria y Sistemas S.A. 20133 Milano Technische Hochschule Darmstadt Pza. Manuel Gomez Moreno Italy Petersenstrasse 30 Edificio...coilsie lred. dlie toC e’quilibcriumu expressions and ’onise-rvat ion~ of at omnic element, at complete determinallit ion of the ’he’nle’al state is...distribution with 10 & 20 degree injection angles 21-1(’ 60 ~0150’"GAP S40o 0O100’GAPS30-" .05 ’ [ " 20- 0 180 360 Deorees from TOC of svirier Fig. 19

  16. DAISY, the best way to author sign language publications

    CSIR Research Space (South Africa)

    Olivrin, G

    2009-09-01

    Full Text Available /detail.shtml?i=41 Eberius, Wolfram (2008): Multimodale Erwiterung Und Distribution Von Digital Talking Books. Germany: Technische universität Dresden. Fédération Internationale de Football Association (2008): Laws of the Game 2008/2009. Switzerland: FIFA... are further discussed that will influence the design of future DAISY standards. 2.1 Creation of Sign Language Content To create a full-text/full-audio and full-text/full-video DAISY test-book, the original content of “Laws of the Game 2008/2009” (FIFA...

  17. Bundesanstalt fuer Martialforschung und -pruefung (BAM). Annual report 2001; Bundesanstalt fuer Materialforschung und -pruefung (BAM). Jahresbericht 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The volume reports the activities of the BAM, (Federal Office for Materials Research and Testing), and its departments for Analytical Chemistry/Reference Materials, Chemical Safety Engineering, Hazardous Materials Containment, Environmental Compatibility of Materials, Technology of Structural Materials, Polymers, Structural Stability and Safety, Materials Protection/Nondestructive Testing, and for Scientific-Technical Interdisciplinary Activities. (MM) [German] Der vorliegende Band berichtet ueber die Aktivitaeten der Bundesanstalt fuer Materialforschung und -pruefung und ihrer Abteilungen Analytische Chemie/Referenzmaterialien, Chemische Sicherheitstechnik, Gefahrgutumschliessungen, Umweltvertraeglichkeit von Materialien, Werkstofftechnik der Konstruktionswerkstoffe, Funktion von Polymeren, Bauwerkssicherheit, Materialschutz/Zerstoerungsfreie Pruefung und Technisch-wissenschaftliche Querschnittsfunktionen. (MM)

  18. Viewpoint – The Role of the German Development Cooperation in Promoting Sustainable Hydropower

    Directory of Open Access Journals (Sweden)

    Cathleen Seeger

    2010-06-01

    Germany’s engagement in the promotion of participatory processes on dam-related issues is building on the WCD and follow-up processes, as outlined in this article. On the global level, BMZ, represented by the Deutsche Gesellschaft für Technische Zusammenarbeit (GTZ, is currently part of the Hydropower Sustainability Assessment Forum (HSAF. On the national level, one example of support is the contribution to and interaction with the Ghana Dam Dialogue, which is facilitated through two local partners: the International Water Management Institute (IWMI and the Volta Basin Development Foundation (VBDF.

  19. Feasibility study on the use of waste heat in mushroom cultivation; Haalbaarheid benutting restwarmte in de paddenstoelenteelt

    Energy Technology Data Exchange (ETDEWEB)

    Gielen, J.H. [DLV Plant, Horst (Netherlands)

    2011-03-15

    This study has examined the technical as well as the economic feasibility of waste heat utilization in a standard cultivation business [Dutch] In dit onderzoek zijn zowel de technische als ook de economische haalbaarheid van toepassingen voor het hergebruik van restwarmte in een standaard teeltbedrijf onderzocht. Gebruikte informatiebronnen voor dit onderzoek waren praktijkervaringen, literatuur en ontwikkelingen in andere sectoren. Behalve de mogelijkheden in de huidige teeltsystemen zijn er mogelijk ook toepassingen denkbaar in de recente ontwikkelingen op het vlak van bedkoeling en bedverwarming. In een dergelijk systeem zal laagwaardige warmte naar verwachting makkelijker inzetbaar zijn.

  20. High speed photography of the plasma flow and the projectiles in the T.U.M. hypervelocity accelerator

    International Nuclear Information System (INIS)

    Igenbergs, E.; Kuczera, H.; Schroeder, B.

    1979-01-01

    The hypervelocity accelerator at the Technische Universitaet Muenchen, FRG, accelerates small projectiles (0.1 to 1.0 mm diameter) to velocities around 20 km/s. The photographic equipment consists of two Cordin single-frame image converter cameras and one TRW image converter camera with streak units and multiple-frame units. They are used for plasma flow diagnostics and the measurement of the position and the velocity of the projectiles. The single-frame cameras are triggered with a Laser light bar and the photographic measurement of the projectile velocity will be compared with Doppler-Radar. (author)

  1. AgroSun. Outline of the prospect of solar PV as a structural chance for the agricultural sector [in the Netherlands]. Phase 1. Inventory, cost effectiveness and benchmark; AgroSun. Verkenning van de kansrijkheid van zon PV als structurele kans voor de agrarische sector. Fase 1. Inventarisatie, rentabiliteit en benchmark

    Energy Technology Data Exchange (ETDEWEB)

    Lemmens, P. [Arvalis Projecten, Roermond (Netherlands); Buiter, W. [ZLTO Advies, Den Bosch (Netherlands); Veefkind, W. [Projecten LTO Noord, Zwolle (Netherlands)

    2011-12-15

    An overview is given of the opportunities of solar PV for the agricultural sector. Attention is paid to the technology, the market, technical indicators, economic aspects of solar panels, policy frameworks and subsidies, practical applications, future prospects, and alternative financing. Also conclusions and recommendations are given for the follow-up phase [Dutch] Dit rapport inventariseert de kansen die zon-pv biedt aan de agrarische sector. Achtereenvolgens: de technologie, de markt, technische kengetallen, economische aspecten van zonnepanelen, beleidsmatige kaders en subsidieregelingen, praktijktoepassingen, het toekomstperspectief en alternatieve financiering. Met conclusies en aanbevelingen voor een vervolgfase.

  2. Microhydrodynamics and complex fluids

    CERN Document Server

    Barthès-Biesel, Dominique

    2012-01-01

    ""In view of the good choice of highly topical subject matter, the book will be of interest to a wide readership, not only among pure scientists. It will be useful to technicians, medical scientists and pharmaceutical chemists as a source of detailed information on advanced flow processes. ... [The chapters] are written in such a way that the reader can quickly absorb the essential information. The articles are of a high scientific standard and include interesting examples from many different areas of rheology."" -Prof. Dr. Heinz Rehage, Institute of Physical Chemistry, Technische Universität

  3. 47{sup th} Annual meeting on nuclear technology (AMNT 2016). Key Topic / Outstanding know-how and sustainable excellence. Workshop: Preserving competence in nuclear technology

    Energy Technology Data Exchange (ETDEWEB)

    Steinwarz, Wolfgang

    2016-10-15

    On the 18{sup th} workshop Preserving Competence in Nuclear Technology 24 young scientists presented the scientific results from their work covering a broad spectrum of technical areas. This demonstrated again the strong engagement of the younger generation as part of the German nuclear society. Prof.Dr.-Ing. Eckart Laurin, Prof.Dr.-Ing. Marco K. Koch, Dr. Katharina Stummeyer, and Dr.-Ing. Wolfgang Steinwarz as members of the jury assessed the written compacts and the oral presentations to award the Siempelkamp Competence Price 2016 to Andreas Wanninger from Technische Universitaet Muenchen.

  4. Dimethylether. Diesel alternative for the future?; Dimethylether. Dieselalternative der Zukunft?

    Energy Technology Data Exchange (ETDEWEB)

    Werner, Martin; Wachtmeister, Georg [Technische Univ. Muenchen (Germany). Lehrstuhl fuer Verbrennungskraftmaschinen

    2010-07-15

    Due to dwindling resources, heavy price volatility and the unilateral dependency on crude oil, the demand for alternatives to diesel and gas fuels is increasing. Dimethylether (DME) seems to present a promising option. Early 2009, within the framework of a six month FVV project (keyword 'DME - Alternative Fuels', purpose No. 1005), a potential analysis of DME as a fuel was carried out at the Chair of Combustion Engines (LVK) at the Technische Universitaet Muenchen (TUM). This paper concludes important information about DME from the point of view of heavy duty engine development. (orig.)

  5. Assessment of PCM in building climate systems; Beoordeling PCM in gebouwklimatisering

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, H. [Verwol Klimatplafonds, Delft (Netherlands)

    2005-09-01

    Insight is given into the impact of phase change materials on the indoor climate in two different types of public buildings (circus tent and a theatre) [Dutch] Organisatoren van 'een dag van autarkische systemen' vragen zich af of deze technische bijeenkomst in een geisoleerde (mobiele) circustent of een monumentaal (statisch) theater moet worden gehouden en of deze dag 's zomers of 's winters moet plaatshebben. De beantwoording vraagt om inzicht in de dimensionering van het vermogen en de capaciteit en het jaarlijks energiegebruik met en zonder PCM (phase change materials)

  6. Antonio Sánchez-Bayón, Sistema de Derecho Comparado y global: de las familias jurídicas mundiales al nuevo Derecho común, Tirant lo Blanch, Valencia, 2012, 161 págs.

    Directory of Open Access Journals (Sweden)

    Natalia del Barrio

    2013-03-01

    Full Text Available Dr. Sánchez-Bayón untersucht in dieser Studie die Notwendigkeit, das Konzept des Vergleichenden Rechts in Zeiten der Globalisierung neu zu überdenken. Die kulturellen, politischen und soziologischen Wechsel müssen an die neue Weltlage angepasst werden. Die juristischen Lösungen müssen verglichen werden, so dass die Spielregeln und der professionelle technische Sprachgebrauch angeglichen werden können; nur so können die Antworten auf die Konsolidierung des gemeinschaftlichen Rechts gefunden werden. Der Autor stellt den formalistischen Positivismus des Staates in Frage.

  7. Neutron scattering (Progress-Report) January - December 1992

    International Nuclear Information System (INIS)

    1993-02-01

    The Laboratory for Neutron Scattering (LNS) is a joint venture between the Eidgenoessische Technische Hochschule Zurich (ETHZ) and the Paul Scherrer Institut Wuerenlingen/Villigen (PSI). The present report summarizes the laboratory's activities in 1992 as well as the work performed by external users at the reactor Saphir. It is intended as an interim description of ongoing research projects and as such may not contain the final conclusions of the analysis. However, the number and quality of the reports reflects very well the standard of experiments performed at the LNS. (author) figs., tabs., refs

  8. Databases on Demand (DBoD)

    OpenAIRE

    Poley, Christoph

    2009-01-01

    In einer der letzten Ausgaben haben wir ausführlich über das Projekt DBoD berichtet. Darin wurde detailliert auf den Inhalt von DBoD, die Benutzergruppen an den Hochschulen, auf technische Details und die Verknüpfung it dem Datenbank-Informationssystem (DBIS) eingegangen. DBoD wird von der Europäischen Union im Rahmen des Europäischen Fonds für regionale Entwicklung (EFRE) gefördert. Seitdem ist ein halbes Jahr vergangen. Zeit, in der sich DBoD von einem Projekt in den Startlöchern hin zu ein...

  9. 47th Annual meeting on nuclear technology (AMNT 2016). Key Topic / Outstanding know-how and sustainable excellence. Workshop: Preserving competence in nuclear technology

    International Nuclear Information System (INIS)

    Steinwarz, Wolfgang

    2016-01-01

    On the 18 th workshop Preserving Competence in Nuclear Technology 24 young scientists presented the scientific results from their work covering a broad spectrum of technical areas. This demonstrated again the strong engagement of the younger generation as part of the German nuclear society. Prof.Dr.-Ing. Eckart Laurin, Prof.Dr.-Ing. Marco K. Koch, Dr. Katharina Stummeyer, and Dr.-Ing. Wolfgang Steinwarz as members of the jury assessed the written compacts and the oral presentations to award the Siempelkamp Competence Price 2016 to Andreas Wanninger from Technische Universitaet Muenchen.

  10. Energy as a technology: Thermodynamics, energy engineering, environment, renewable energy, rational energy use. 2. rev. ed.; Technologie Energie: Thermodynamik, Energietechnik, Umwelt, regenerative Energien, rationeller Energieeinsatz

    Energy Technology Data Exchange (ETDEWEB)

    Schuberth, R.

    2000-07-01

    The book discusses the technical and scientific fundamentals and the ecological consequences of anthropogenic energy conversion. The information is to make the public energy discussion more rational and less emotional. [German] Trotz oder gerade wegen der duesteren Zukunftsaussichten sind sachliche und fundierte Informationen ueber die Zusammenhaenge zu diesem Thema erforderlich. In diesem Buch werden schwerpunktmaessig die technisch-naturwissenschaftlichen Sachverhalte und die oekologischen Folgeerscheinungen, die im Zusammenhang mit der anthropogenen Energieumwandlung auftreten, dagestellt. Diese Kenntnisse sollten auch zu einer Versachlichung der Energiediskussion und einer rationaleren Beurteilung der Situation fuehren koennen. (orig.)

  11. Medical radiology terminology. French - English - German. Woerterbuch der physikalisch-technischen Begriffe der medizinischen Radiologie. Franzoesisch - Englisch - Deutsch

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    Standardization achievements in the field of radiology induced the IEC to compile the terminology used in its safety and application standards and present it in publication 788 (1984 issue), entitled 'Medical radiology terminology'. The objective pursued is to foster the use of standard terminology in the radiology standards. The value of publication 788 lies in the fact that it presents definitions of terms used in the French and English versions of IEC standards in the field of radiology, and thus facilitates adequate translation of these terms into other languages. In the glossary in hand, German-language definitions have been adopted from the DIN standards in cases where the French or English versions of definitions are identical with the German wording or meaning. The numbers of DIN standards or sections are then given without brackets, ahead of the text of the definition. In cases where correspondance of the various texts is not so good, or reference should be made to a term in a DIN standard, the numbers are given in brackets.

  12. Simulation of a model predictive room temperature control by use of an ideal weather forecast; Simulation einer praediktiven Raumtemperaturregelung unter Verwendung einer idealen Wettervorhersage

    Energy Technology Data Exchange (ETDEWEB)

    Goertler, Gregor [Fachhochschulstudiengaenge Burgenland GesmbH, Pinkafeld (Austria). Kernkompetenzbereich Energie- und Umweltmanagement; Beigelboeck, Barbara

    2010-12-15

    Due to the use of MPC (Model Predictive Control) for room heating applications users and constructors expect nameable energy savings. By usage of a simulation for a special case the energy saving potential of predictive control algorithm for room temperature control in connection with an ideal weather forecast, in comparison to established algorithms (PI-control, two level controller) is estimated. The controlled system with the control variable room temperature is a room with floor heating which was modelled in TRNSYS. A linear state space model of the controlled system was derived with suitable identification methods. This model was used by the predictive control algorithm, which was programmed in MATLAB. The weather data was taken from the TRNSYS library and has been made available also for the control algorithm, so that an ideal weather forecast was established. For the example considered in this paper, the amount of energy saving was 10 % per year with the MPC-controller compared to a PI-controller. (Copyright copyright 2010 Ernst and Sohn Verlag fuer Architektur und technische Wissenschaften GmbH and Co. KG, Berlin)

  13. Quality assurance of in-situ-gammaspectrometry. International comparison measurement at the K-RISK-phantom 2015; Qualitaetssicherung der In-situ-Gammaspektrometrie. Internationale Vergleichsmessung an der K-RISK-Phantomwand 2015

    Energy Technology Data Exchange (ETDEWEB)

    Haas, G.; Schupfner, R. [Regensburg Univ. (Germany). ZRN-URA-Lab.; Buss, K. [Bayerisches Landesamt fuer Umwelt, Kulmbach (Germany)

    2016-07-01

    During the last years the collimated in-situ-gammaspectrometry established itself as a powerful mean for free- release of buildings, parts of buildings, walls and ground area. To accomplish a suitable possibility for quality assurance of in-situ-gammaspectrometry, the K-RISK-phantom wall was developed and built at the University of Regensburg on the authority of the state office for environmental protection, Kulmbach. The K-RISK-phantom is a large surface calibration wall made of concrete which allows simulating different realistic three-dimensional wall contaminations. Contrary to many other calibration phantoms the K-RISK phantom permits completely reversible three-dimensional activity distributions. The comparison measurement is a useful tool for quality assurance and allows the participants to review their measurements relating to measurement, calibration or analysis. 19 institutions (industry, surveyor, authorities) from Germany, Austria and Switzerland participated at the comparison measurement.

  14. A superconducting microcalorimeter for low-flux detection of near-infrared single photons

    Energy Technology Data Exchange (ETDEWEB)

    Dreyling-Eschweiler, Jan

    2014-07-15

    This thesis covers the development and the characterization of a single photon detector based on a superconducting microcalorimeter. The detector development is motivated by the Any Light Particle Search II (ALPS II) experiment at DESY in Hamburg, which searches for weakly interacting sub-eV particles (WISPs). Therefore, a detection of low-fluxes of 1064 nm light is required. The work is divided in three analyses: the characterization of a milli-kelvin (mK) cryostat, the characterization of superconducting sensors for single photon detection, and the determination of dark count rates concerning 1064 nm signals. Firstly, an adiabatic demagnetization refrigerator (ADR) is characterized, which allows to reach mK-temperatures. During commissioning, the ADR cryostat is optimized and prepared to stably cool superconducting sensors at 80 mK±25 μK. It is found that sensors can be continuously operated for ∝20 h before recharging the system in <2 h. Furthermore, the adiabatic system reaches a chance of success of ∝80 % for a recharge without technical problems. Secondly, superconducting sensors are analyzed. The focus is on microcalorimetric transition-edge sensors (TESs) based on 20 nm Tungsten (W) films fabricated by the U.S. National Institute of Standards and Technology (NIST). NIST TESs have a near unity detection efficiency for 1064 nm light (literature value). The energy resolution for 1064 nm signals is measured to be <8 %. The exponential falling time of a photon pulse is 1.5 μs. Furthermore, by determining TES parameters, it is found that the linear TES theory describes measured photon pulses well. The TES response is read out by a superconducting quantum interference device (SQUID) fabricated by Physikalisch-Technische Bundesanstalt (PTB). The system bandwidth is measured to be 0.9 MHz. Finally, the operation in the ADR cryostat as well as the ALPS II laboratory is optimized. This setup forms the ALPS TES detector. Thirdly, the background is measured to

  15. Solarthermische Kraftwerksentwicklung (STKE) - development of solar thermal power plants. Technical aspects. Final report; Solarthermische Kraftwerksentwicklung (STKE). Technischer Teil. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Pitz-Paal, R.

    2000-01-01

    This project started on 1 January 1996 with DM 3.7 million funds from the BMFT. Originally scheduled for three years, it was extended by a further 11 months for various reasons. Its intention was to reduce the cost of future solar thermal power plants. Particular emphasis was given to the parabolic trough technology asit is closest to commercialisation. Three strategies were involved: 1. Further development and qualification of components for the parabolic trough collector (WG PAREX); 2. Development of instruments for measuring radiation flux distribution in parabolic trough collectors (WG PARMESAN); 3. Development, verification and application of software tools for analysing the complex dynamic response of solar thermal power plants (WG SISTA). [German] Das hier dargestellte Projekt begann am 1.1.1996 und wurde vom Bundesministerium fuer Forschung und Technologie (BMFT) mit etwa 3,7 Mio. DM gefoerdert. Es hatte eine geplante Laufzeit von drei Jahren, wurde aber aufgrund von unterschiedlichen Verzoegerungen (Mitarbeiterwechsel, Defekte an Versuchsanlagen) kostenneutral um 11 Monate verlaengert. Gesamtziel des Projekts war es, zur Kostensenkung bei zukuenftigen solarthermischen Kraftwerken beizutragen. Dabei stand insbesondere die Parabolrinnentechnik im Vordergrund, da sie im Vergleich zu anderen solarthermischen Technologien einer weiteren kommerziellen Vermarktung derzeit am naechsten steht. Es wurden drei Schwerpunkte verfolgt: 1. Die Weiterentwicklung und Qualifizierung von Komponenten fuer den Parabolrinnenkollektor (Arbeitspaket 'Parabolrinnenexperimente', kurz PAREX) 2. Die Entwicklung von Messtechnik zur Bestimmung von Strahlungsflussverteilung bei Parabolrinnenkollektoren (AP 'Parabolrinnen-Messanlage', kurz PARMESAN) 3. Die Erstellung, Verifikation und Anwendung von Softwarewerkzeugen zur Analyse des komplexen dynamischen Verhaltens von solarthermischen Kraftwerken (AP 'Simulation solarthermischer Anlagen', kurz SISTA) (orig.)

  16. Petal Integration for the CMS Tracker End Caps

    CERN Document Server

    Bergauer, Thomas; Friedl, Markus; Hansel, S; Hrubec, Josef; Krammer, Manfred; Pernicka, Manfred; Beaumont, Willem; De Wolf, Eddi A; Bouhali, Othmane; Clerbaux, Barbara; Dewulf, Jean-Paul; De Lentdecker, Gilles; Mahmoud, Tariq; Neukermans, Lionel; Van der Velde, C; Vanlaer, Pascal; Wickens, John; D'Hondt, Jorgen; Goorens, Robert; Heyninck, Jan; Tavernier, Stefaan; Udo, Fred; Van Lancker, Luc; Bonnet, Jean-Luc; De Callatay, Bernard; Delaere, Christophe; Florins, Benoit; Grégoire, Ghislain; Keutgen, Thomas; Lemaître, Vincent; Michotte, Daniel; Militaru, Otilia; Piotrzkowski, Krzysztof; Rouby, Xavier; Teyssier, Daniel; Van der Donckt, M; Ageron, Michel; Baulieu, Guillaume; Bonnevaux, Alain; Boudoul, Gaelle; Chabanat, Eric; Chabert, Eric Christian; Contardo, Didier; Della Negra, Rodolphe; Estre, Nicolas; Giraud, Noël; Haroutunian, Roger; Lumb, Nicholas; Mirabito, Laurent; Perriès, Stephane; Trocmé, Benjamin; Vanzetto, Sylvain; Agram, Jean-Laurent; Drouhin, Frédéric; Ernenwein, Jean-Pierre; Fontaine, Jean-Charles; Berst, Jean-Daniel; Brom, Jean-Marie; Didierjean, Francois; Hosselet, J; Goerlach, Ulrich; Graehling, Philippe; Gross, Laurent; Juillot, Pierre; Lounis, Abdenour; Maazouzi, Chaker; Ollivetto, C; Strub, Roger; Van Hove, Pierre; Adolphi, Roman; Brauer, Richard; Braunschweig, Wolfgang; Esser, Hans; Feld, Lutz; Karpinski, Waclaw; Klein, Katja; König, Stefan; Kosbow, M; Lübelsmeyer, Klaus; Olzem, Jan; Ostapchuk, Andrey; Pandoulas, Demetrios; Pierschel, Gerhard; Schael, Stefan; Schmitz, Stefan Antonius; Schultz von Dratzig, Arndt; Siedling, Rolf; Weber, Markus; Wittmer, Bruno; Wlochal, Michael; Beissel, Franz; Bock, E; Flossdorf, E; Flügge, Günter; Hermanns, Thomas; Heydhausen, Dirk; Jahn, Dieter; Kaussen, Gordon; Linn, Alexander; Poettgens, Michael; Pooth, Oliver; Stahl, Achim; Zoeller, Marc Henning; Butz, Erik; Flucke, Gero; Klanner, Robert; Pein, Uwe; Schirm, Norbert; Schleper, Peter; Steinbruck, G; Stoye, Markus; Van Staa, Rolf; Atz, Bernd; Blüm, Peter; de Boer, Wim; Bogelsbacher, F; Barvich, Tobias; Dehm, Philip; Dierlamm, Alexander; Dirkes, Guido; Fahrer, Manuel; Fernández, J; Frey, Martin; Furgeri, Alexander; Gregoriev, E; Hartmann, Frank; Heier, Stefan; Kaminski, Jochen; Ledermann, Bernhard; Muller, Th; Piaseki, C; Sabellek, Andreas; Simonis, Hans-Jürgen; Steck, Pia; Theel, Andreas; Weiler, Thomas; Weseler, Siegfried; Zhukov, Valery; Freudenreich, Klaus

    2008-01-01

    This note describes the assembly and testing of the 292 petals built for the CMS Tracker End Caps from the beginning of 2005 until the summer of 2006. Due to the large number of petals to be assembled and the need to reach a throughput of 10 to 15 petals per week, a distributed integration approach was chosen. This integration was carried out by the following institutes: I. and III. Physikalisches Institut - RWTH Aachen University; IIHE, ULB \\& VUB Universities, Brussels; Hamburg University; IEKP, Karlsruhe University; FYNU, Louvain University; IPN, Lyon University; and IPHC, Strasbourg University. Despite the large number of petals which needed to be reworked to cope with a late-discovered module issue, the quality of the petals is excellent with less than 0.2\\% bad channels.

  17. Synchrotron radiation laboratories at the Bonn electron accelerators. a status report

    Science.gov (United States)

    Hormes, J.

    1987-07-01

    At the Physikalisches Institut of the University in Bonn experiments with synchrotron radiation were carried out ever since 1962. At the moment (June 1986) all work takes place in the SR-laboratory at the 2.5 GeV synchrotron. A 3.5 GeV stretcher ring (ELSA) is under construction and will come into operation at the end of 1986. This accelerator will also run as a storage ring for synchrotron radiation experiments and a laboratory to be used at this machine is also under consideration. The SR experiments which are carried out in Bonn try to take advantage of the fact that we are still using a high energy synchrotron for our work. Besides basic research also applied work is done using synchrotron radiation even as a production tool for X-ray lithography.

  18. Design of a beam optic for the transfer channel between the LINAC 2 and the 2.5 GeV synchrotron

    International Nuclear Information System (INIS)

    Schneider, W.

    1992-10-01

    The accelerator facility at the Physikalisches Institut of Bonn University is being extended by a linear accelerator (LINAC 2) for the preacceleration of polarized electron beams to an energy level of 20 MeV. The beam optics of the transfer channel, which guides the electrons to the injection point of the 2.5 GeV-Synchrotron, has been designed. Because the emittance of the electron beam leaving the LINAC 2 is unknown at the movement, the beam optics and the aperture of the transfer channel has been layed out for a high transmission even for the worst case scenario. The quadrupol magnets needed for focusing and matching the beam has been constructed and tested. The integration of a system for beam diagnosis and position correction in the transfer channel is planned. (orig.) [de

  19. Technical safety ingas supply - prevention of manipulations; Technische Sicherheit in der Gasversorgung - Manipulationsabwehr

    Energy Technology Data Exchange (ETDEWEB)

    Guther, F. [Ingenieurbuero Guther, Hausham (Germany)

    2000-07-01

    Most accidents in gas supply are gas explosions wilfully caused for the purpose of suicide, killing, stealing gas, or causing damage to property. The gas industry attempts to minimize these manipulations by means of practicable technical, organisational and communicative measures. [German] Die vorsaetzliche Herbeifuehrung von Gasexplosionen mit der Absicht der Selbsttoetung, der Toetung Dritter, des Gasdiebstahls oder der Sachbeschaedigung stellt die schwerwiegendste Unfallursache in der oeffentlichen Gasversorgung dar. Dem Gasfach kommt damit noch staerker als bisher die Aufgabenstellung zu, mit praktikablen technischen und eventuell organisatorischen wie auch kommunikativen Moeglichkeiten diese Manipulationsfaelle auf ein Mindestmass zu reduzieren. (orig.)

  20. Über die Gefügeausbildung technischer Magnesiumlegierungen in industriellen Gießprozessen

    OpenAIRE

    Klaus, Gerald

    2011-01-01

    The demand for lightweight constructions and light weight materials is probably as old as the transportation of people and goods. The aspiration in gaining even better light weight materials with increased mechanical properties is an old, but still actual topic. At this point magnesium alloys can be applied to fullfill this demand. Actually available commercial alloys have to be improved regarding their mechanical properties, especially for increased temperatures. This work aims to gain a bet...

  1. Annual report on research and development 1980 of the Institut fuer Technische Physik

    International Nuclear Information System (INIS)

    1981-06-01

    Progress of the following working areas of the institute is reported: magnets for fusion technology (TESPE experiment, the Large Coil Task (LCT)); components and technology (development of high field superconductors (Nb 3 Sn, Nb 3 Al)), cooling techniques (HELITEX experiment); system studies on fusion reactor components; magnets for research and technology; basic research related to superconductivity; cryo-energy technology; the cryogenic engineering infrastructure of the institute. (GSCH)

  2. District heating service connections. Technical recommendations. 4. ed. Hausanschluesse an Fernwaermenetze. Technische Richtlinien

    Energy Technology Data Exchange (ETDEWEB)

    1986-01-01

    The fourth edition of the 'Technical regulations - district heating service connections' constitutes a completely revised version answering to the considerable developments and changes the house service sector experienced between 1975 and 1985. Analyses and practical experiences have proved to show that precision thermostats which, depending on the mode of lines and layout of the service system allow to spare central temperature control systems, still have a decisive influence on the design of district heating service stations. The revised chapter on steam line service connections focuses on problems concerning the metering of condensates and the connection of secondary water heating networks to steam lines. The reader finds an updated selection of diagrams as well as a revised appendix listing the AGFW codes of practice and recommendations, relevant DIN standards and relevant VDE/VDI recommendations.

  3. Vorming en aanpassingsvermogen van intersectorale technologisch georiënteerde onderzoeksconsortia : Analyse technische kokerview

    NARCIS (Netherlands)

    Cuijpers, Y.; Lokhorst, C.; Bos, A.P.

    2008-01-01

    ASG werkt samen met een breed scala aan partijen aan de ontwikkeling en toepassing van nieuwe generaties draadloze sensornetwerken. In de consortia LOFAR en WASP werken bedrijven, instituten en universiteiten samen in de toepassingsgebieden landbouw, ouderenzorg, automobielindustrie, astronomie en

  4. Kijken is grijpen : zelfbedieningswinkels, technische dynamiek en boodschappen doen in Nederland na 1945

    NARCIS (Netherlands)

    Sluijter, B.

    2007-01-01

    The history of food self-service shops in the Netherlands has only recently been linked explicitly to the field of history of technology. The main question posed in this research is how food self-service shops arose in the Netherlands, how they developed and what explanations could be given for

  5. Right, laws, regulations and technical building systems; Recht, Gesetze, Verordnungen und Technische Gebaeudesysteme

    Energy Technology Data Exchange (ETDEWEB)

    Kranz, H.R. [Siemens AG, Karlsruhe (Germany)

    1995-12-31

    Chapter 23 of the anthology about building control gives an overview of the laws and regulations in the field of technical building systems. The following fields are discussed: license regulations in the field of building trade, communication law, environmental responsibility law, building right, European directives, laws and regulations of the Federal Government and the Laender. (BWI) [Deutsch] Kapitel 23 des Sammelbandes ueber Building Control gibt einen Ueberblick ueber Recht, Gesetze und Verordnungen im Bereich der Technischen Gebaeudesysteme. In diesem Zusammenhang kommen folgende Bereiche in Frage: Lizenzrecht im Bauwesen; Fernmelderecht; Umwelthaftungsgesetz; Baurecht; Europaeische Richtlinien; Gesetze und Verordnungen des Bundes und der Laender. (BWI)

  6. Treatment of malignant biliary obstructions via the percutaneous approach; Interventionen bei malignen Gallenwegstenosen

    Energy Technology Data Exchange (ETDEWEB)

    Radeleff, B.A.; Lopez-Benitez, R.; Hallscheidt, P.; Grenacher, L.; Libicher, M.; Richter, G.M.; Kauffmann, G.W. [Radiologische Klinik der Ruprecht-Karls-Universitaet Heidelberg (Germany). Abteilung fuer Radiodiagnostik

    2005-11-01

    This paper gives an overview of experience and success of percutaneous transhepatic interventions in malignant biliary obstruction. Even after exhaustion of surgical and endoscopic therapy options, the percutaneously inserted stents provide effective palliation. The palliative treatment of malignant jaundice using a stent is an established procedure in clinical practice, particularly whenever the endoscopic, transpapillary approach is not possible due to high obstructions or previous surgery. The technical success rate is very high (about 95-100%), and the complication rate is about 10-30%. Since the patency rate of stents is higher than that of plastic endoprostheses, their primary use is justified despite higher costs, provided the patients are adequately selected. (orig.) [German] Vorgelegt wird eine Uebersicht ueber den gegenwaertigen Stellenwert radiologischer Interventionen bei malignen Gallenwegstenosen, die nur bei 10-20% der Patienten heilbar sind. Wenn ein endoskopisch transpapillaerer Zugang nicht moeglich ist, z. B. bei hohen Obstruktionen oder nach frueheren Eingriffen, ermoeglichen die perkutane transhepatische Punktion und Implantation von Metallendoprothesen eine gute Palliation. Die perkutane Gallengangdrainage und Stentplatzierung sind fuer den erfahrenen, interventionell taetigen Radiologen wenig kompliziert und mit einer Erfolgsrate von 95-100% dem endoskopischen Vorgehen deutlich ueberlegen. Morbiditaet und Mortalitaet der endoskopischen Verfahren waren in aelteren Arbeiten noch geringer als die der perkutanen Methoden. Aktuellen Studien zufolge sind beide Verfahren gleichwertig, wahrscheinlich aufgrund technischer Verbesserungen der perkutanen Interventionen. Die technische Erfolgsrate bei der Stentapplikation liegt ueber 95%. Mittels perkutaner transhepatischer biliaerer Drainageneinlage (PTCD) eingelegte Metallstents bleiben haeufiger und laenger offen als Plastikstents. Bei entsprechender Lebenserwartung des Patienten ist ihr Einsatz daher

  7. Research project ``Geoscientific, geotechnological and process-related research to optimize the available processes for geothermal energy utilisation under the aspect of long-term exploitation``; Forschungsprojekt ``Geowissenschaftliche, geotechnologische und verfahrenstechnische Forschungsarbeiten zur Vervollkommnung des Verfahrens der Nutzung geothermischer Ressourcen im Hinblick auf das Langzeitverhalten

    Energy Technology Data Exchange (ETDEWEB)

    Rohstock, B; Schneider, H [Geothermie Neubrandenburg GmbH (Germany)

    1997-12-01

    The research project was started with the objective of developing the essential geological-technical-technological parts of the utilisation of highly-mineralised thermal waters for heating. It is based on the findings from the drilling and testing of 29 deep geothermal wells, the erection and operation of Geothermal Heating Stations in Northeast Germany until 1990. The operation of the Waren (Mueritz) and Neubrandenburg Geothermal Heating Stations including their modernisation and the solution of problems which occurred sometimes give proof of the principal technical-technological implementability of thermal water utilisation for energetic purposes. Matter of concern is the recirculation of the thermal water after being used for balneological purposes to the main flow of water used for energetic purposes without affecting subsequent reinjection. The conditioning of the thermal water before and after use for bathing and balneo-therapeutic purposes is another problrm. The essential results are presented here. (orig.) [Deutsch] Das Forschungsvorhaben wurde mit dem Zeit der Vervollkommnung der wesentlichen geologisch-technisch-technologischen Teilbereiche der waermeseitigen Nutzung von hochmineralisierten Thermalwaessern aufgenommen. Die mit dem Niederbringen und Testen von 29 Geothermie-Tiefbohrungen, der Errichtung und dem Betrieb der Geothermischen Heizzentralen in Nordostdeutschland bis 1990 gewonnen Erkentnisse bildeten dabei die Grundlage. der seither fortgesetzte Betrieb der Geothermischen Heizzentralen in Waren (Mueritz) und Neubrandenburg einschliesslich deren Modernisierung sowie die zwischenzeitlich aufgetretenen und im positiven Sinne geloesten Probleme unterstreichen die grundsaetzlich geloeste technisch-technologisce Realisierbarkeit der waermetechnischen Thermalwassernutzung. Zu loesen ist die Problematik der Aufbereitung des stofflich zu nutzenden Thermalwassers vor und nach Einsatz im Bade- und medizinisch-therapeutischen Bereich. Im Vortrag werden die

  8. Alternative Antriebe für Automobile: Hybridsysteme, Brennstoffzellen, alternative Energieträger

    Science.gov (United States)

    Stan, Cornel

    Über die Realisierungsmöglichkeiten zukünftiger Antriebskonzepte - von Hybridsystemen Elektro-/Verbrennungsmotor über Brennstoffzellen bis zu alternativen Energieträgern wie Wasserstoff oder Alkohol - werden fundierte Kriterien der Qualität eines Antriebs entscheiden. Leistungsdichte, Drehmomentverlauf, Beschleunigungscharakteristik, spezifischer Energieverbrauch sowie Emission chemischer Stoffe und Geräusche sind dafür wichtige Merkmale zur Qualitätsbeurteilung. Die Verfügbarkeit und die Speicherfähigkeit vorgesehener Energieträger, die technische Komplexität, Kosten, Sicherheit, Infrastruktur und Service werden die Randbedingungen für die Einführung realisierbarer Konzepte alternativer Antriebe für Automobile stellen.

  9. Autonomy of industry - possibilities and limits in a pluralistic society

    International Nuclear Information System (INIS)

    Schoch, W.

    1976-01-01

    Examples of free enterprise acting on its own responsibility are given which relate to the state-independent area in which the state has no need to intervene, or to an area in which the state cooperates with the autonomous forces of society in solving tasks as one of the responsible partners. The examples are a) the Arbeitsgemeinschaft Druckbehaelter (AD), b) the Deutsches Institut fuer Normung (DIN), c) the Deutscher Dampfkessel-Ausschuss (DDA) and the Kerntechnischer Ausschuss (KTA) as the initiators of standards, and d) the Technische Ueberwachungs-Vereine (TUeV) as service organizations. (orig./HP) [de

  10. Visualisierung analoger Schaltungen durch 3-D Animation von transienten SPICE-Simulationen

    Directory of Open Access Journals (Sweden)

    J. Becker

    2007-06-01

    Full Text Available Für das Zeichnen analoger Schaltpläne wird oft versucht, die Potentialverteilung in der entsprechenden Schaltung auszunutzen, um eine Platzierung der Bauteile nach abfallendem Potential vorzunehmen. Mit Hilfe von Computerunterstützung gelingt es, eine verallgemeinerte dreidimensionale Platzierungsstrategie anzuwenden, die allein auf Grund der Potentialwerte einer Schaltung die automatische Generierung einer technisch exakten Potentialdarstellung erlaubt. Somit ist es möglich, die Ergebnisse von transienten SPICE-Simulationen in jedem Zeitschritt darzustellen und eine Animation des zeitlichen Verhaltens zu erzeugen. Die Umsetzung dieser Methode zur Einbettung in eine webbasierte Lern – und Arbeitsplattform wird im Folgenden erläutert.

  11. Visualisierung analoger Schaltungen durch 3-D Animation von transienten SPICE-Simulationen

    Science.gov (United States)

    Becker, J.; Manoli, Y.

    2007-06-01

    Für das Zeichnen analoger Schaltpläne wird oft versucht, die Potentialverteilung in der entsprechenden Schaltung auszunutzen, um eine Platzierung der Bauteile nach abfallendem Potential vorzunehmen. Mit Hilfe von Computerunterstützung gelingt es, eine verallgemeinerte dreidimensionale Platzierungsstrategie anzuwenden, die allein auf Grund der Potentialwerte einer Schaltung die automatische Generierung einer technisch exakten Potentialdarstellung erlaubt. Somit ist es möglich, die Ergebnisse von transienten SPICE-Simulationen in jedem Zeitschritt darzustellen und eine Animation des zeitlichen Verhaltens zu erzeugen. Die Umsetzung dieser Methode zur Einbettung in eine webbasierte Lern - und Arbeitsplattform wird im Folgenden erläutert.

  12. Hybride Lernarrangements in der universitären Weiterbildung. Das Beispiel Educational Media

    Directory of Open Access Journals (Sweden)

    Claudia de Witt

    2003-11-01

    Full Text Available Der Artikel beschreibt eine hybride Lernform, in der Online-Lernphasen mit Präsenzphasen kombiniert werden. "Educational Media" ist ein weiterbildender Masterstudiengang an der Universität Essen-Duisburg, der technische und didaktische Kenntnisse zur Medienerziehung vermittelt. Nach einer Bedarfs- und Zielgruppenanalyse wurde ein Curriculum entwickelt, das hier vorgestellt wird. Während in der Anfangszeit Präsenzphasen und Gruppenelemente (Chatforen besonders wichtig sind, steigt in späteren Phasen das Bedürfnis nach selbstgesteuerten Lernperioden. Eine intensive persönliche Betreuung durch Tutoren sowie die Anbindung an die Institution steigern die Motivation und verringern die Abbrecherquote.

  13. Informatische Pädagogik - pädagogische Informatik. Beispiele für fächerverbindende Projekte mit medienerzieherischem Anspruch

    Directory of Open Access Journals (Sweden)

    Michael Weigend

    2001-12-01

    Full Text Available Mit der Profilbildung der Schulen und mit der Entwicklung individueller schulinterner Lehrpläne, sind in zunehmendem Masse Kopplung von Oberstufenkursen und fächerverbindenes Unterrichten gefragt. In diesem Beitrag werden Projekte vorgestellt, die eine Kooperation der Fächer Informatik und Erziehungswissenschaft voraussetzen. Inhaltlich stellen die Neuen Medien den Bezugspunkt dar: multimediale und zum Teil interaktive Anwendungen, wie digitale Animationen, Spiele und Bildschirm-Experimente können von den Schüler/innen selbst entwickelt und als Medien eingesetzt werden, wobei technische und gesellschaftliche Fragen der Mediengestaltung und der Mediennutzung zu reflektieren sind.

  14. Implications of the Pressurized Equipment Directive of the EC for the German gas trade and industry; Die Bedeutung der EG-Druckgeraeterichtlinie fuer das deutsche Gasfach

    Energy Technology Data Exchange (ETDEWEB)

    Jannemann, T.B. [DVGW Deutsche Vereinigung des Gas- und Wasserfaches e.V., Bonn (Germany)

    2003-06-01

    The standards and requirements to be met by the equipment, components and materials manufactured and used in Germany are specified in the DVGW code, of which some parts and content will need amending and adjustment to the EC Pressurized Equipment Directive. The aim of this harmonization is to remove technical barriers to trade within the European Union. (orig./CB) [German] Die konkreten Anforderungen an Geraete, Bauteile und Materialien sind im DVGW-Regelwerk festgeschrieben. Im Rahmen der Realisierung des EU-Binnenmarktes wird das DVGW-Regelwerk teilweise europaeisch harmonisiert. Ziel ist die Beseitigung technischer Handelshemmnisse unter gleichzeitiger Beruecksichtigung des europaeisch relevanten Schutzniveaus. (orig.)

  15. Digital building planning - digital construction; Digitale Gebaeudeplanung - digitales Bauen

    Energy Technology Data Exchange (ETDEWEB)

    Friedrichs, K. [Karlsruhe Univ. (T.H.) (Germany). Fakultaet fuer Architektur

    1995-12-31

    In chapter 3 of the anthology about building control the following aspects are discussed: digital building planning and digital construction, which are characterised by an increasing complexity of planning, buildings, construction technology and construction processes. In this respect the digital-technical scenarios, passive and active objects as well as digital construction are described. (BWI) [Deutsch] Kapitel 3 des Sammelbandes ueber Building Control ist den Themen Digitale Gebaeudeplanung und Digitales Bauen gewidmet, die durch die zunehmende Komplexitaet von Planung, Gebaeuden, Bautechnologien und -prozessen bedingt sind. In diesem Zusammenhang werden folgende Themen angesprochen: Digitale technische Szenarien, passive und aktive Objekte sowie digitales Bauen. (BWI)

  16. Uterine fibroid embolization with spheric micro-particles using flow guiding: safety, technical success and clinical results; Uterusmyomembolisation mit sphaerischen Mikropartikeln unter Flusssteuerung: Sicherheit, technischer Erfolg und klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M.; Radeleff, B.; Kauffmann, G.W. [Ruprecht-Karls-Univ. Heidelberg, Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik (Germany); Rimbach, S. [Ruprecht-Karls-Univ. Heidelberg, Univ.-Frauenklinik (Germany); RWTH Aachen, Univ.-Frauenklinik (Germany)

    2004-11-01

    Materials and Methods: Twenty of the first 26 consecutive patients referred for potential UFE were enrolled in the study. Pre-interventional MRI was used to assess morphologic contraindication to UFE. The embolization procedures were performed from a unilateral femoral approach using 4F selective catheters in straight vessels, >2 mm in diameter, and micro-catheters in smaller and tortuous arteries. The endpoint of the 'flow guided' embolization was defined by reaching the angiography 'pruned tree' appearance and sluggish flow in the main stem of the uterine artery. Assessment of morphologic mid term success was done by MRI 10 days, 3 months, 6 months, 9 months and 1 year after UFE. The clinical mid term success was assessed by having questionaires completed for menstrual bleeding, retention of clinical (symptomatic) benefit and quality of life. Results: Technical success was 100%, with 8 minor (2 post-interventional collapses, 2 hematomas, 4 relevant post-embolizations syndromes, 1 spontaneous expulsion of a submucous myoma) and 3 major complications (1 hysterectomy because of vaginal bleeding for 5 weeks, 1 transient amenorrhea and 1 spontaneous expulsion of myoma with transient bleeding requiring admission). In 17 of 19 patients, MRI showed total fibroid devascularization throughout the entire follow-up. The average shrinkage of the dominant fibroid was 71.3% at one year. The menstrual bleeding record in the cohort group fell from an average of 501.6 before treatment to 76.2 points at one year. At the same time, the clinical symptoms significantly improved. The patient satisfaction with the applied therapy was >95% at 1 year. One patient with residual fibroid perfusion underwent a second procedure, which achieved complete devascularization and adequate clinical success at one year. The second patient with incomplete devascularization had a persistent clinical benefit. (orig.)

  17. Optimisation of small-scale hydropower using quality assurance methods - Preliminary project; Vorprojekt: Optimierung von Kleinwasserkraftwerken durch Qualitaetssicherung. Programm Kleinwasserkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, S.; Staubli, T.

    2006-11-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a preliminary project that examined how quality assurance methods can be used in the optimisation of small-scale hydropower projects. The aim of the project, to use existing know-how, experience and synergies, is examined. Discrepancies in quality and their effects on production prices were determined in interviews. The paper describes best-practice guidelines for the quality assurance of small-scale hydro schemes. A flow chart describes the various steps that have to be taken in the project and realisation work. Information collected from planners and from interviews made with them are presented along with further information obtained from literature. The results of interviews concerning planning work, putting to tender and the construction stages of these hydro schemes are presented and commented on. Similarly, the operational phase of such power plant is also examined, including questions on operation and guarantees. The aims of the follow-up main project - the definition of a tool and guidelines for ensuring quality - are briefly reviewed.

  18. From physics to metaphysics. Physical unification and string approach; Von der Physik zur Metaphysik. Physikalische Vereinheitlichung und Stringansatz

    Energy Technology Data Exchange (ETDEWEB)

    Hedrich, R.

    2007-07-01

    In spite the string approach as attempt of a nomologically unified comprehension of all interactions inclusively the gravitation exists already over three decades the physical principles on which it is based are yet completely unclear; and not the most unimportant empirically provable quantitative prediction exists. Without empirical data, which would be incompatible with the stablished theories - quantum-field theoretical standard model anf general relativity - only the conceptual incompatibility of both together with the unification idea yields a motivation for the string approach. By this however physics threatens to exceed under consequent continuation of their hitherto successful strategies the methodological framework of empirical sciences.

  19. More efficient resource utilization of geothermal plants. Technical possibilities and their assessment; Effizientere Ressourcenausnutzung geothermischer Anlagen. Technische Moeglichkeiten und deren Bewertung

    Energy Technology Data Exchange (ETDEWEB)

    Kock, Nils; Kaltschmitt, Martin [Technische Univ. Hamburg-Harburg, Hamburg (Germany). Inst. fuer Umwelttechnik und Energiewirtschaft

    2011-12-15

    The geological conditions in Germany allow maximum temperatures between 160 to 170 C free well head taking techno-economic constraint into consideration. This makes an electricity production for purely technical reasons possible, but only with low efficiencies due to physical constraints. That's why it assault big amounts of waste heat. For example, the existing geothermal power plants in Germany provide in average 18% of electricity and 82% of heat. This heat is use so far only to a very small degree. Even is a district heating system is operated to supply private households, this heat is used with less than 2.500 h per year. That's why the still hot thermal water is press back into the underground without any further utilization. For these reasons to achieve a technical and economic optimization it should be the aim to find different reasonable options to use this waste heat. One possibility is the coupling with a drying process at the location of the geothermal plant. Such options will be analyzed from a technical and economic point of view and some conclusions will be drawn. (orig.)

  20. Nuclear energy in the 21{sup st} century - free from nuclear danger myths

    Energy Technology Data Exchange (ETDEWEB)

    Akimoto, Yumi [Mitsubishi Materials Corp. (MMC), Tokyo (Japan)

    2002-01-01

    In the past year, 2000, the approx. 430 nuclear power plants worldwide covered some 16-17% of the electricity supply. This corresponds, e.g., to the energy equivalent of the aggregate oil production of Saudi Arabia and Iran over the same period of time. The first major steps towards the peaceful uses of nuclear energy in the world were initiated after the 'Atoms for Peace' speech by the then U.S. President, Dwight D. Eisenhower, before the United Nations on December 8, 1953. They were followed by two decades of intense reasearch and development work. The know-how obtained and developed further in this way made countries, such as France and Japan, greatly expand their nuclear power programs under the impact of the two oil price crises in the seventies. As a result, a powerful potential is now available for electricity supply - also in the European Union - which not only offers continuity of supply but also makes an important contribution to reducing emissions which affect our climate. Despite its technical and economic success, the peaceful use of nuclear power, like other technical developments, has become an object of societal criticism in many countries. Two major aspects in this regard are issues of proliferation and the evaluation of the risk of radiation. Although the proliferation risk has been settled technically for the light water reactor line, and can be practically excluded, this has not so far been put to use politically. As far as the effects of low radiation doses are concerned, the question must be answered to what extent the application of the linear dose-effect relationship is an adequate and meaningful reflection of biological reality, and how radiation effects can be evaluated effectively. In the light of the problems to be solved in the 21st century, nuclear power and its potential can and will make important contributions to supplying energy worldwide. (orig.) [German] In den vergangenen Jahren haben die ca. 430 Kernkrafte weltweit