WorldWideScience

Sample records for x-ray fluorescence determination

  1. X-ray fluorescence spectroscopic determination of heavy metals and ...

    African Journals Online (AJOL)

    Purpose: To determine the heavy metal and trace element composition of the powdered aerial parts of Origanum sipyleum L. and its water extract. Methods: The heavy metal and trace elements content of the powdered plant material and 2 % aqueous extract were evaluated by x-ray fluorescence spectroscopy with silicon ...

  2. Use of X-Ray Fluorescence Spectrometry to Determine Trace ...

    African Journals Online (AJOL)

    This paper deals with application of X-ray fluorescence spectrometry for the detection of trace elements in graphic. An X-ray spectrometer was constructed and used to carry out measurements on graphite spheres impregnated with different chemical elements. The intensities of the lines of these trace elements, as function of ...

  3. Blood selenium content determination by X-ray fluorescence

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    1987-01-01

    The presence of some elements in small amounts (traces) in the human body is of foremost importance for the prevention and treatment of several diseases. It has been recently shown that traces of selenium in blood are closely related to the occurrence of miotonic distrophy, a muscular disease that is affecting a significant percentage of the population. This work describes a simple procedure to determine selenium in human blood serum by energy dispersive X-ray fluorescence analysis. Final quantification is achieved through the addition of titanium as an internal standard. (Author) [es

  4. Determination of technetium by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bermudez, J.I.; Greaves, E.D.; Nemeth, P.

    2000-01-01

    We describe a technique using total reflection x-ray fluorescence (TXRF) for determination of Technetium produced by elution of chromatography generators with physiological saline solutions. The analysis with the 18.41 keV K α line of Technetium was accomplished with monochromatized K α radiation from a silver anode x-ray tube operated at 45 keV and 20 mA. This radiation at 22.104 keV is efficiently coupled to the 21.054 keV absorption edge of Tc. It is also of advantage in the direct analysis of organic and saline properties of the Tc-bearing samples. Quantification was accomplished by internal standard addition of Ga and using an interpolated value of the sensitivity for Tc between Molybdenum and Rhenium. Data processing was carried out with the QXAS-AXIL software package. System sensitivity was found adequate for direct Tc determination of eluted saline solutions. The interest and advantages of the use of the technique as an auxiliary in the synthesis and characterization of Tc-labeled radiopharmaceuticals used for diagnosis in nuclear medicine are discussed. Detection limits in the matrices analyzed are reported. (author)

  5. Sensitivity of in vivo X-ray fluorescence determination of skeletal lead stores

    International Nuclear Information System (INIS)

    Sokas, R.K.; Besarab, A.; McDiarmid, M.A.; Shapiro, I.M.; Bloch, P.

    1990-01-01

    Eighteen patients with known past occupational lead exposure underwent parenteral diagnostic chelation with ethylenediaminetetraacetic acid and x-ray fluorescent determination of in vivo skeletal lead stores at the distal styloid process of the ulna and at the temporal base bone using a cobalt 57 source and measuring lead Ka x-rays. X-ray fluorescent lead measurements in both locations correlated with results of diagnostic chelation. Using a post-chelation urinary excretion of greater than 600 micrograms lead/24 h as the definition of high-lead stores, sensitivity of x-ray fluorescence at the wrist and temple was 56% and 39%, respectively

  6. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  7. Simultaneous determination of actinides by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Cohen, V.H.

    1990-01-01

    The x-ray spectrometric simultaneous determination of uranium and plutonium in simulated Purex Process solutions is described. The method is accomplished by intensity measurements of the L α sub(1) lines. The thin film technique for sample preparation and thorium as an internal standard had been used. An evaporation technique had been also tested for low concentration uranium solutions. In the measurement range 0,05 - 130 U g/L, 0,5 - 20 Pu g/L linear calibration curves were effected. The standard deviation in the concentration range 10 to 130 g/L was 3,5%, 4% in the 1 to 10 g/L and 13% in 0,05 to 1 g/L for uranium determination and 4% for plutonium determination in the range of 1 to 20 g/L. The sensitivity of the method was about 3,62 μg to U and 3,95 μg to Pu. Uranium and plutonium do not reciprocally interfere with one another until U/Pu ≅ 90 m/m. The fission product as interfering elements were also verified. Finally, uranium and plutonium were determined in simulated Purex Process solutions within the requested accuracy for control method. (author)

  8. Determination of chlorine in coal by X-ray fluorescence spectrometry method

    Energy Technology Data Exchange (ETDEWEB)

    Marek, S.; Bojarska, K. [Central Mining Institute, Katowice (Poland). Dept. of Environmental Monitoring

    1997-12-31

    Determination of chlorine contents in coal is essential for both environmental protection and its technological use. The existing method of chlorine determination in coal are titration methods which have considerable errors particularly in the low concentration range. The elaborated method with the use of X-ray fluorescence spectrometry in a comparison to the other methods is much faster and has better precision and accuracy. The principle of the method lies in the measurement of X-ray fluorescence radiation intensity which is emitted by chlorine in a sample and its comparison with standards. The calibration of the elaborated XRF method is based on natural coals having various concentrations of chlorine within the whole range of its occurrence in Polish coals. Concentrations for the calibration purpose were obtained by the determination of chlorine contents in selected coals by atomic absorption spectrometry method. The procedure of sample preparation for direct X-ray measurements, instrumental measuring conditions and the way of calibration curve preparation are described in the paper. All X-ray measurements were done with a Phillips sequential X-ray fluorescence spectrometer. A double anode Cr-Au X-ray tube with maximum power 3000 MW was used as the excitation source. 5 figs., 4 tabs.

  9. Choice of excitation source for determination of rare earth elements with radioisotope excited X ray fluorescence

    International Nuclear Information System (INIS)

    Zhang Quanshi; Chang Yongfu

    2000-01-01

    The comparisons of two radioisotope source ( 241 Am and 238 Pu) which are the most available in the radioisotope excited X Ray Fluorescence (XRF) analysis technique and two characteristic X ray series (KX and LX) analyzed for the determination of the rare-earth (RE) elements were investigated in detail. According to the principle of emission and detection of X ray , the relative excitation efficiencies were calculated by the some fundamental physical parameters including the photoelectric mass attenuation coefficient, the fluorescent yield, the absorption jump factor, the emission probability of the detected fluorescent line with reference to other liens of the same series etc., The advantages and disadvantages of the two conditions are discussed. These results may determine the optimal excitation and detection conditions for different rare-earth elements. The experimental results with nine rare-earth elements (Ce, Nd, Sm, Tb, Tm, Ho, Er, Yb and Lu) are in agreement with the results of theoretical calculations

  10. X-Ray fluorescence determination of the mobile forms of toxic elements in meadow chernozems

    International Nuclear Information System (INIS)

    Belikov, K.N.; Blank, A.B.; Shevtsov, N.I.

    1997-01-01

    An X-ray fluorescence method for determining mobile forms of Mn, V, Cr, Co, Ni, Zn, and Pb in meadow chernozems was developed. It is based on the extraction of analytes with an acetate-ammonia buffer solution and the evaporation of the obtained filtrate with carbon powder followed by the X-ray fluorescence analysis of the dry residue. The effect of concomitants on the analytical signals of elements under determination was examined. It was suggested to spike samples with barium in order to decrease analytical errors. (author)

  11. X-ray fluorescence determination of cobalt in iron-manganese oceanic concretions

    International Nuclear Information System (INIS)

    Ivanenko, V.V.; Kustov, V.N.; Metelev, A.Yu.; Rakita, K.A.

    1989-01-01

    A method was developed for resolution of weak analytical lines for elements determined by radionuclide-excited X-ray fluorescence multi-element analysis. The method was used aboart for determining cobalt and some other commercially valuable elements in iron-manganese concretions of Pacific ocean 109 Cd was used as an ionizing radiation source

  12. Some applications of x-ray fluorescence spectrography to the determination of uranium and thorium

    International Nuclear Information System (INIS)

    Jones, R.W.

    1959-04-01

    Several methods for the determination of uranium and thorium by X-ray fluorescence spectrography are described. In pure solutions the sensitivity for these elements is 5-10 ppm. For solutions containing gross concentrations of impurities, strontium is added as an internal standard. Precision and accuracy of the determinations are about 1% when working in the optimum concentration range. (author)

  13. The X-ray fluorescent method for determination of total sulphur in bituminous coals

    International Nuclear Information System (INIS)

    Widowska-Kusmierska, J.; Siess, K.

    1979-01-01

    The X-ray fluorescent technique for the determination of total sulphur covering concentrations from 0,1 to 10% has been applied for bituminous coals showing a great variability in qualitative and quantitative composition of mineral matter (ash). The described method is a quick one giving results during one hour. The obtained good accuracy of determinations gives prospects for wide industrial application. (author)

  14. Determination of Fe and Zn in healing plants by radionuclide X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Harangozo, M.; Toelgyessy, J.; Tomecek, O.; Ruzicka, I.; Cejpek, K.

    1999-01-01

    Radionuclide X-ray fluorescence method was used for the determination of Fe and Zn in healing plants (Sage, Peppermint, Stinging, Common Agrimony, Milfoil, Ribwort, Tansy, White Dead-Nettle). 238 Pu exciting source and Si/Li semiconductor detector were used for the determination. (author)

  15. Rapid extraction and x-ray fluorescence determination of gold in rock

    International Nuclear Information System (INIS)

    Lobanov, F.I.; Logunova, S.A.; Popov, A.M.; Krasnopevtseva, E.V.

    1994-01-01

    The optimal conditions for gold extractional recovery by melts of aliphatic monocarboxylic acids mixtures (C ≥ 16) with additions of di-2-ethylhexyldithiophosphoric acid, di-n-oxtylsulfide and alkylaniline were determined. A rapid method of extraction and X-ray fluorescence detection of gold in the presence of considerable amounts of Fe, Cu, Pb, Cd, Zn and Bi was developed

  16. Determination of rhenium in molybdenite by X-ray fluorescence: A combined chemical-spectrometric technique.

    Science.gov (United States)

    Solt, M W; Wahlberg, J S; Myers, A T

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

  17. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    Science.gov (United States)

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  18. X-ray fluorescence analysis for trace element determination in foodstuff chemistry

    International Nuclear Information System (INIS)

    Wildanger, W.

    The physical fundamentals of X-ray fluorescence analysis are given and the routine spectrometers described. The basic principles are given of analytical methods used in qualitative and quantitative fluorescence analyses. Examples are given of the use of the method in a number of fields and the possibility and usefulness is discussed for the determination of trace elements in foodstuffs. The preparation of samples, preliminary concentration of components and calibration methods are discussed. (M.K.)

  19. Determination of Ti, Cr, Cu and Ta in niobium oxide by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Dixit, R.M.; Deshpande, S.S.

    1986-01-01

    An x-ray fluorescence method for the determination of Ti, Cr, Cu and Ta in niobium oxide has been developed. Samples/standards in powder form are mixed with boric acid in the proportion of 1:1 (400 mg. each). Double layer pellets are prepared by pressing this mixture over a primary boric acid pellet. Philips PW-1220, a semiautomatic x-ray spectrometer with tungsten target x-ray tube for excitation and LiF (200) crystal for dispersion have been used. The determination range is from 0.005 to 0.1per cent for Ti and Cr, 0.01 to 0.1per cent for Cu and 0.05 to 1per cent for Ta. (author)

  20. Radionuclide X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Cechak, T.

    1994-01-01

    The author's achievements in the title field are summarized and discussed. The following topics are dealt with: (i) principles of radionuclide X-ray fluorescence analysis; (ii) mathematical methods in X-ray fluorescence analysis; (iii) Ross differential filters; (iv) application of radionuclide X-ray fluorescence analysis in the coal industry (with emphasis on the determination of the ash content, sulfur content, and arsenic content of coal); and (v) evaluation of the X-ray fluorescence analyzer from the radiological safety point of view. (P.A.)

  1. Determination of plutonium in nitric acid solutions using energy dispersive L X-ray fluorescence with a low power X-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Py, J. [Laboratoire Chrono-Environnement, UMR CNRS 6249, Université de Franche-Comté, 16 route de Gray, F-25030 Besançon (France); Commissariat à l’Énergie Atomique, Centre de Valduc, F-21120 Is-sur-Tille (France); Groetz, J.-E., E-mail: jegroetz@univ-fcomte.fr [Laboratoire Chrono-Environnement, UMR CNRS 6249, Université de Franche-Comté, 16 route de Gray, F-25030 Besançon (France); Hubinois, J.-C.; Cardona, D. [Commissariat à l’Énergie Atomique, Centre de Valduc, F-21120 Is-sur-Tille (France)

    2015-04-21

    This work presents the development of an in-line energy dispersive L X-ray fluorescence spectrometer set-up, with a low power X-ray generator and a secondary target, for the determination of plutonium concentration in nitric acid solutions. The intensity of the L X-rays from the internal conversion and gamma rays emitted by the daughter nuclei from plutonium is minimized and corrected, in order to eliminate the interferences with the L X-ray fluorescence spectrum. The matrix effects are then corrected by the Compton peak method. A calibration plot for plutonium solutions within the range 0.1–20 g L{sup −1} is given.

  2. Determination of low concentrations of thorium in geological materials by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Bayon, A.

    1981-01-01

    An X-ray fluorescence method for the determination of thorium in geological samples down to 2 ppm ThO 2 has been developed. To achieve this determination limit an exposed area of the sample 42.5 mm in diameter is used, working with a molybdenum target tube operated at 90 kV and 30 m A. Corrections for background and line interference of the Rb Kα radiation have been carefully considered and empirical correction coefficients calculated. (Author) 3 refs

  3. Quantitative determination of uranium in organic solution by X-ray fluorescence

    International Nuclear Information System (INIS)

    Leyt, D.V. de; Colangelo, C.H.

    1987-01-01

    An X-ray fluorescent method for the determination of uranium in tributilphosphate-kerosene-nitriacid solution has been developed. Chemical properties of the matrix elements were studied in order to select a convenient procedure to determine samples and standards on the same way. The method avoids the destruction of the organic material and has proved to be very useful for the fast control of uranium concentration. (Author) [es

  4. Determination of small amounts of aluminum in iron and steel by x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Ito, Minao; Sato, Shoki; Narita, Masanao

    1981-01-01

    The accuracy of X-ray fluorescence analysis for determining aluminum in steel is generally poor when the aluminum content is below 0.1%. In this study, it is confirmed that the existence of inhomogeneous acid-insoluble aluminum causes the poor accuracy of X-ray fluorescence analysis. The accuracy can be improved by adding granular ferro-zirconium to molten steel when sampling. By using this method, the accuracy of determining aluminum was 0.0024% for low alloy steels and 0.0022% for stainless steels as the standard deviation obtained for a series of differences between an analytical result and a standard value. Corrections for overlapping of the chromium spectrum, and for absorption and enhancement effects of co-existent elements are not necessary for the analysis of low alloy steels, whereas these corrections are necessary for the analysis of stainless steels. (author)

  5. Zinc content determination in rice and other agriproducts by X-ray fluorescence

    International Nuclear Information System (INIS)

    Denis Alpizar, Otoniel; Diaz Rizo, Oscar

    2009-01-01

    The Zn content in regular consumption foodstuff (rice, some vegetables and roots) in Cuba is reported. Concentrations are determined by X-Ray Fluorescence analysis using a set of organic standards doped with Zn. The accuracy of the analytical procedure was validated using the Certified Reference Materials IAEA 393 and y MA-B-3/TM. The obtained results show rice as the major Zn bioaccumulator of the studied agriproducts and the main Zn source in Cuban human diet. (author)

  6. Zinc content determination in rice and other agricultural products by X-ray fluorescence

    International Nuclear Information System (INIS)

    Denis Alpizar, Otoniel; Diaz Rizo, Oscar

    2010-01-01

    The Zn content in regular consumption foodstuff (rice, some vegetables and roots) in Cuba is reported. Concentrations are determined by X-Ray Fluorescence analysis using a set of organic standards doped with Zn. The accuracy of the analytical procedure was validated using the Certified Reference Materials IAEA 393 and y MA-B-3/TM. The obtained results show rice as the major Zn bioaccumulator of the studied agricultural products and the main Zn source in Cuban human diet. (author)

  7. Development of unified X-ray fluorescent analysis to determine rhenium content in multicomponent oxide compositions

    International Nuclear Information System (INIS)

    Drobot, D.V.; Belyaev, A.V.; Kutvitskij, V.A.; Rysev, A.P.

    1999-01-01

    A procedure to prepare rhenium-containing glass-like specimens on the basis of bismuth and boron oxides is proposed. The glasses produced are studied by X-ray fluorescent analysis and routine spectrometric thiocyanate analysis. The results make it possible to determine rhenium in oxide mixtures in the range of its content 0.01 - 10% with S r = 0.03 [ru

  8. Determination of calcium and iron in limestone by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Sovtsova, M.K.

    1977-01-01

    The results of determining calcium and iron content in limestone by X-ray fluorescence method are described. The 109 Cd isotape was chosen as a source for excitation, as it permited to reduce the concentration degeneration in the range of large Ca contents due to the larger energy of the primary radiation. The root-mean-square deviation from the data of chemical analysis was +-0.02%FeO and +-0.22%CaO

  9. Determination of potassium concentration in organic samples by means of x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Soto Moran, R.L.; Szgedi, S.

    1993-01-01

    By means of x-ray fluorescence analysis and the inner standard method using KH 2 PO 4 as the added chemical compound, potassium concentration of roots, stems , leaf, flowers and grains from Quinua (Chenopodium Quinoa Willd). which was previously treated with a nitrogen ed fertilizers has been determined taking into account the increasing effect the average atomic number due to used standard. Experimental errors are lower than 10 %

  10. Trace elements determination in red and white wines using total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Anjos, M.J.; Lopes, R.T.; Jesus, E.F.O. de; Moreira, S.; Barroso, R.C.; Castro, C.R.F.

    2003-01-01

    Several wines produced in different regions from south of Brazil and available in markets in Rio de Janeiro were analyzed for their contents of elements such as: P, S, Cl, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Multi-element analysis was possible with simple sample preparation and subsequent analysis by total-reflection X-ray fluorescence using synchrotron radiation. The measurement was carried at the X-ray fluorescence beamline in the Synchrotron Light Source Laboratory in Campinas, Brazil. The levels of the various elements obtained were lower in the Brazilian wines than the values generally found in the literature. The present study indicates the capability of multi-element analysis for determining the contents of various elements present in wines coming from Brazil vineyards by using a simple, sensitive and precise method

  11. Determination of copper in geological materials by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Bayon, A.

    1981-01-01

    X-ray fluorescence has been applied to the determination of copper content of geological materials in the concentration range of 0.01 to % CuO. A molybdenum target tube Is used, samples being presented in finely-ground powder form. Various methods for the correction for background and Instrumental copper interferences have been considered. To correct for matrix effects different tube scattered primary radiations have been tested as references or internal standards. MoK(41 - (C) provides the most suitable results. The use of influence empirical coefficients for the effect of iron on copper and of mass absorption coefficients has also been considered. For samples with a high content of lead, several procedures to correct for I t s influence have been investigated. Comparison between data obtained by X-ray fluorescence and wet-chemical techniques indicated good agreement. (Author) 6 refs

  12. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  13. Determination of rare-earth elements in rocks by isotope-excited X-ray fluorescence spectrometry

    DEFF Research Database (Denmark)

    Kunzendorf, Helmar; Wollenberg, H.A.

    1970-01-01

    Isotope-excited X-ray fluorescence spectrometry furnishes a rapid determination of rare-earth elements in unprepared rock samples. The samples are excited by 241Am γ-rays, generating X-ray spectra on a multichannel pulse-height analyser. Gaussian peaks of the Kα and Kβ X-ray energies are treated ......-ray spectrometric scan of a longitudinally sliced drill core showed a close correlation between rare-earth abundances and appropriate minerals.......Isotope-excited X-ray fluorescence spectrometry furnishes a rapid determination of rare-earth elements in unprepared rock samples. The samples are excited by 241Am γ-rays, generating X-ray spectra on a multichannel pulse-height analyser. Gaussian peaks of the Kα and Kβ X-ray energies are treated...

  14. Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

    Science.gov (United States)

    Srivastava, Anjali; Heisinger, Brianne J.; Sinha, Vaibhav; Lee, Hyong-Koo; Liu, Xin; Qu, Mingliang; Duan, Xinhui; Leng, Shuai; McCollough, Cynthia H.

    2014-03-01

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. In particular, x-ray fluorescence (XRF) can be very useful for the determination of minor and trace materials in the kidney stone. The X-ray fluorescence measurements were performed at the Radiation Measurements and Spectroscopy Laboratory (RMSL) of department of nuclear engineering of Missouri University of Science and Technology and different kidney stones were acquired from the Mayo Clinic, Rochester, Minnesota. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. A new type of experimental set-up was developed and utilized for XRF analysis of the kidney stone. The correlation of applied radiation source intensity, emission of X-ray spectrum from involving elements and absorption coefficient characteristics were analyzed. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF technique. The elements which were identified from this techniques are Silver (Ag), Arsenic (As), Bromine (Br), Chromium (Cr), Copper (Cu), Gallium (Ga), Germanium (Ge), Molybdenum (Mo), Niobium (Nb), Rubidium (Rb), Selenium (Se), Strontium (Sr), Yttrium (Y), Zirconium (Zr). This paper presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF instrumental activation analysis technique.

  15. Determination of low concentrations of thorium in granites using X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Shigematsu, H.M.; Sato, I.M.; Iyer, S.S.

    1981-03-01

    An analytical method for the accurate determination of low concentrations of thorium in rocks using X-ray fluorescence technique, was developed. A tungsten tube was utilized for the production of X-rays. The samples were prepared in the form of double layer pressed pellets using boric acid as a binding agent. The concentration of thorium was determined by measuring the intensity of the characteristic first order Th L α line. The calibration was carried out with USGS rock standards AGV-1, GSP-1 and G-2. Seven granite rocks samples from Granite Mountains of Wyoming, USA, supplied by Dr. Stuckless. Also were analysed. The results obtained were compared with values obtained in others laboratories using different analytical methods. The analyses show that the thorium is concentrated in accessory minerals and presented a non-uniform distribution, making sampling an important factor in the analysis of thorium. A discussion of the precision and accuracy of the method is presented. (Author) [pt

  16. Determination of rare-earth elements in rocks by isotope-excited X-ray fluorescence spectrometry

    DEFF Research Database (Denmark)

    Kunzendorf, Helmar; Wollenberg, H.A.

    1970-01-01

    Isotope-excited X-ray fluorescence spectrometry furnishes a rapid determination of rare-earth elements in unprepared rock samples. The samples are excited by 241Am γ-rays, generating X-ray spectra on a multichannel pulse-height analyser. Gaussian peaks of the Kα and Kβ X-ray energies are treated......-ray spectrometric scan of a longitudinally sliced drill core showed a close correlation between rare-earth abundances and appropriate minerals....

  17. Application of X-ray fluorescence (WDXRF): thickness and chemical composition determination of thin films

    International Nuclear Information System (INIS)

    Scapin, Valdirene de Oliveira.

    2004-01-01

    In this work a procedure is described for thickness and quantitative chemical composition of thin films by wavelength dispersion X-ray fluorescence (WDXRF) using Fundamental Parameters method. This method was validated according to quality assurance standard and applied sample Al, Cr, TiO2, Ni, ZrO2 (single thickness) and Ni/Cr (double thickness) on glass; Ni on steel and metallic zinc and TiO2 on metallic iron (single thickness), all the sample were prepared for physical deposition of vapor (PVD). The thickness had been compared with Absorption (FRX-A) and Rutherford Backscattering Spectrometry (RBS) methods; the result showed good efficiency of the fundamental parameters method. Sample structural characteristics analyzed by X ray diffraction (XRD) showed any influence in the thickness determinations. (author)

  18. Metals determination in wood treated by synchrotron radiation X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de; Medeiros, Jean Gabriel da Silva; Tomazello Filho, Mario

    2005-01-01

    The paper describes the use of X-Ray fluorescence analysis for distribution and quantification of metals in the hardwood (Eucalyptus sp) and softwood (Pinus sp) treated with CCA (copper-chromium-arsenic). The sapwood/heartwood for hardwood sample and the growth-rings for softwood sample were analyzed. The samples were scanned in 320 mm steps in the vertical direction. For excitation of the elements a white beam synchrotron radiation of ∼ 320 x 180 mm was employed and for the X-ray detection a Si(Li) semiconductor detector. The elements K, Ca, Cr, Mn, Cu, Zn and As were determined. Fundamental parameters were used to quantify the elements concentrations. (author)

  19. Thin coating thickness determination using radioisotope-excited x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Del Castillo, Lorena A.; Calix, Virginia S.

    2001-01-01

    Three different approaches on thin coating thickness determination using a radioisotope-excited x-ray fluorescence spectrometry were demonstrated and results were compared. A standard of thin layer of gold (Au) on a nickel (Ni) substrate from the US National Bureau of Standards (with a nominal thickness of 0.300505 microns of at least 99.9% Au electrodeposited over 2 nils of Ni) on low carbon steel (1010) was analyzed using a Cd 109-excited XRF system. Au thickness computations were done using the (a) thin standard approach, (b) thick standard approach, and (c) x-ray absorption method (ASTM A754-79 1982). These three methods yielded results within the limit set by the American Society for Testing Materials (ASTM), which is +/-3%. Of the three methods, the thick standard yielded the best result with 0.124% error. (Author)

  20. Metals determination in wood treated by synchrotron radiation X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Silva, Richard Maximiliano da Cunha [Centro de Energia Nuclear na Agricultura, Piracicaba, SP (Brazil)]. E-mail: maxcunha@cena.usp.br; Medeiros, Jean Gabriel da Silva; Tomazello Filho, Mario [Sao Paulo Univ., Piracicaba, SP (Brazil). Escola Superior de Agricultura Luiz de Queiroz]. E-mail: jeangm@esalq.usp.br; mtomazel@esalq.usp.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Barroso, Regina Cely [Universidade do Estado, Rio de Janeiro, RJ (Brazil)]. E-mail: cely@uerj.br

    2005-07-01

    The paper describes the use of X-Ray fluorescence analysis for distribution and quantification of metals in the hardwood (Eucalyptus sp) and softwood (Pinus sp) treated with CCA (copper-chromium-arsenic). The sapwood/heartwood for hardwood sample and the growth-rings for softwood sample were analyzed. The samples were scanned in 320 mm steps in the vertical direction. For excitation of the elements a white beam synchrotron radiation of {approx} 320 x 180 mm was employed and for the X-ray detection a Si(Li) semiconductor detector. The elements K, Ca, Cr, Mn, Cu, Zn and As were determined. Fundamental parameters were used to quantify the elements concentrations. (author)

  1. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  2. use of x-ray fluorescence spectrometry to determine trace elements ...

    African Journals Online (AJOL)

    NIJOTECH

    Abstract. This paper deals with application of X-ray fluorescence spectrometry for the detection of trace elements in graphic. An X-ray spectrometer was constructed and used to carry out measurements on graphite spheres impregnated with different chemical elements. The intensities of the lines of these trace elements, ...

  3. The determination, by x-ray-fluorescence spectrometry, of gold in activated charcoal

    International Nuclear Information System (INIS)

    Austen, C.E.

    1977-01-01

    A rapid method is described for the determination of gold in activated charcoal by X-ray-fluorescence spectrometry. Compensation for matrix effects is achieved by means of platinum that is added for use as an internal standard. Calibration is achieved by use of a series of synthetic standards that are made by the spiking of barren charcoal with gold and platinum. The limit of determination is about 8 p.p.m. of gold, and the relative standard deviation is 1,2 per cent at a concentration level of 2300 p.p.m

  4. Thorium determination by X-ray Fluorescence Spectrometry in simulated thorex process solutions

    International Nuclear Information System (INIS)

    Yamaura, M.; Matsuda, H.T.

    1989-01-01

    The X-ray fluorescence method for thorium determination in aqueous and organic (TBP-n-dodecane) solutions is described. The thin film-technique for sample preparation and a suitable internal standard have been used. Some parameters as analytical line, internal standard, filter paper, paper geometry, sample volume and measurement conditions were studied. Uranium, fission products, corrosion products and thorex reagent components were studied as interfering elements in the thorium analysis, as well as the matrix effect by using the thorex process simulated solutions the method to thorium determination in irradiated thorium solutions was applied. (M.J.C.) [pt

  5. Total reflection X-ray Fluorescence determination of interfering elements rubidium and uranium by profile fitting

    Science.gov (United States)

    Dhara, Sangita; Khooha, Ajay; Singh, Ajit Kumar; Tiwari, M. K.; Misra, N. L.

    2018-06-01

    Systematic studies to assess the analytical parameters obtained in the total reflection X-ray fluorescence (TXRF) determinations of interfering elements Rb and U using profile fitting are reported in the present manuscript. The X-ray lines Rb Kα and U Lα having serious spectral interference (ΔE = 218 eV), have been used as analytical lines. The intensities of these X-ray lines have been assessed using profile fitting. In order to compare the analytical results of Rb determinations in presence of U, with and without U excitation, synchrotron radiation was tuned to energy just above and below the U Labs edge. This approach shall excite both Rb Kα and U Lα simultaneously and Rb Kα selectively. Finally, the samples were also analyzed with a laboratory based TXRF spectrometer. The analytical results obtained in all these conditions were comparable. The authenticity of the results was assessed by analyzing U with respect to Rb in Rb2U(SO4)3, a standard reference material for U. The average precision obtained for TXRF determinations was below 3% (RSD, n = 3, 1σ) and the percent deviation of TXRF values from the expected values calculated on the basis of sample preparation was within 3%.

  6. Determination of coal ash content by the combined x-ray fluorescence and scattering spectrum

    Science.gov (United States)

    Mikhailov, I. F.; Baturin, A. A.; Mikhailov, A. I.; Borisova, S. S.; Fomina, L. P.

    2018-02-01

    An alternative method is proposed for the determination of the inorganic constituent mass fraction (ash) in solid fuel by the ratio of Compton and Rayleigh X-ray scattering peaks IC/IR subject to the iron fluorescence intensity. An original X-ray optical scheme with a Ti/Mo (or Sc/Cu) double-layer secondary radiator allows registration of the combined fluorescence-and-scattering spectrum at the specified scattering angle. An algorithm for linear calibration of the Compton-to-Rayleigh IC/IR ratio is proposed which uses standard samples with two certified characteristics: mass fractions of ash (Ad) and iron oxide (WFe2O3). Ash mass fractions have been determined for coals of different deposits in the wide range of Ad from 9.4% to 52.7% mass and WFe2O3 from 0.3% to 4.95% mass. Due to the high penetrability of the probing radiation with energy E > 17 keV, the sample preparation procedure is rather simplified in comparison with the traditional method of Ad determination by the sum of fluorescence intensities of all constituent elements.

  7. Determination of silver in ancient coins by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Pairatana, C.

    1976-01-01

    45 coins of late Ayudhaya and Bangkok periods was analyzed quantitatively by x-ray fluorescence technique using radioisotopic sources Pm - 147/A1 and Am - 241. The fluorescence x-rays were detected by Lithium drifted silicon detector and 1024 channels pulse height analyzer. The procedure was laid a stress on non-destructive methods which could be utilized for analysing various kinds of antiquities and work of arts such as metals, alloys, pottery, ceramics, paper, textile, wood etc

  8. X-ray fluorescence diffractionless analyzer for determining light element content in iron ore mixtures

    International Nuclear Information System (INIS)

    Yuksa, L.K.; Kochmola, N.M.; Bondarenko, V.P.; Bogdanov, V.K.

    1986-01-01

    Diffractionless X-ray fluorescence analyzer for detecting calcium oxide and silicon dioxide contents in dry iron ore materials has been developed. The analyzer includes a charging unit, sample-conveying device, spectrometric units for detecting calcium and silicon, computing racks and sample-removing device. Results of calcium oxide and silicon dioxide analyses in iron ore mixtures are presented. Errors are evaluated. It is shown that the analyzer provides high accuracy of one-time determinations, as well as reading constancy for a long time

  9. Use of X-ray fluorescence for metal determination in polymers

    International Nuclear Information System (INIS)

    Guidorizzi, Lorenza

    1996-01-01

    X-Ray fluorescence spectrometry was used to determine metals and non-metals in polyester polymers. The greatest advantage of this technique over others like Atomic Absorption or Plasma Emission is that no sample previous treatment (like calcination or acid digestion) is required. Other advantage of this method is its fastness allowing a complete analysis in just few minutes. On the other hand, this method requires metals higher than 15 ppm. Below those values there is a loss of the analysis' precision. Another advantage of this technique is the possibility of making qualitative metal analysis, scanning unknown samples and identifying the found peaks automatically. (author)

  10. Determination of low concentrations of uranium in granite samples by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Diaz-Guerra, J.P.

    1981-01-01

    An x-ray fluorescence method for the determination of uranium in granite samples for concentrations ranging from 3 to 100 ppm U 3 O 8 has been developed. To this purpose a sample holder, specially designed, allowing the irradiation of sample surfaces 42.5 mm in diameter and a molybdenum tube operating with a power of 2700 W (90 kV, 30 mA) are used. The background influence and the spectral interferences from rubidium and strontium have been taken into account and specific correction coefficients have been computed. A Basic program facilitates the report of the analytical results. (author)

  11. Sample preparation of waste water to determine metallic contaminants by X-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gonzalez Olivos, Javier.

    1987-01-01

    Trace X-ray fluorescence spectroscopy analysis in liquid samples is preceded by sample preparation, which usually consists in the precipitation of the metallic ions and concentration over a thin cellulose filter. The samples preparation of waste water by this method is not efficient, due to the great amount of organic and insoluble matter that they contain. The purpose of this work was to determine the optimal value of pH in order to adsorbe all the insoluble matter contained in a waste water sample in the activated charcoal, so that the metallic ions could be precipitated and concentrated on a thin filter and determinated by X-ray fluorescence spectroscopy. A survey about the adsorption of some ions in activated charcoal in function of the pH was made for the following: Cr 3+ , Fe 3+ , Ni 2+ , Cu 2+ , Zn 2+ , Se 2+ , Hg 2+ , and Pb 2+ . It was observed that at pH 0, the ions are not adsorbed, but Cu 2+ and Zn 2+ are adsorbed in small amount; at pH 14, the ions are adsorbed, excluding Se, which is not adsorbed at any value of pH. If a waste water sample is treated at pH 0 with activated charcoal to adsorbe the organic and insoluble matter, most of the metallic ions are not adsorbed by the activated charcoal and could be precipitated with APDC (ammonium 1-pirrolidine dithio carbamate salt) and concentrated on a thin filter. The analysis of the metallic ions contained on the filter and those adsorbed in the activated charcoal by X-ray fluorescence spectroscopy, gave the total amount of the ions in the sample. (author)

  12. The determination, by x-ray-fluorescence spectrometry, of gold and uranium on resin

    International Nuclear Information System (INIS)

    Jacobs, J.J.; Balaes, A.M.E.

    1983-01-01

    The problems encountered in the determination of gold and uranium that are present simultaneously in a sample of resin were considered, and new background positions, as well as correction factors for background lift and partial spectral overlap, were determined for use in the X-ray-fluorescence measurement of these elements. The agreement between the results obtained by the use of the X-ray-fluorescence method and those obtained by atomic-absorption spectrophotometry were found to be satisfactory. The relative standard deviation in the former measurements is 0,005 at a concentration of 1000 p.p.m., and the working range of the calibrations is 15 to 1000 p.p.m. These limits can be extended by further dilution of the sample. The limits of determination are 6 p.p.m. in the briquette prepared from a sample of resin and 18 p.p.m. in the sample when the maximum mass of the sample is 3 g. The procedure is intended primarily for use in the rapid determination of gold and uranium when no analyses for other elements are required. The time taken for the analysis is 2 hours for 10 samples when 6 standards are used. A computer programme that was developed for the processing of the data is appended as part of a laboratory method

  13. Chlorine determination in (U, Pu)C fuel by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Misra, Nand Lal; Dhara, Sangita; Mudher, Khush Dev Singh; Aggarwal, Suresh K.; Thakur, Uday Kumar; Shah, Dipti; Sawant, R.M.; Ramakumar, K.L.

    2007-01-01

    A Total Reflection X-ray Fluorescence (TXRF) method for the determination of chlorine in (U,Pu)C has been developed. The method involves calibration of the instrument with standard solutions and validation of TXRF determination of chlorine using synthetic standard solutions. Cl K α line excited with W L α source was used for TXRF determinations of chlorine. Chlorine present in trace amounts in (U,Pu)C samples was first separated by pyro hydrolysis. The evolved chlorine, in form of HCl, was collected in 5 mM NaOH solution. This solution was analyzed for chlorine by Total Reflection X-ray Fluorescence Spectrometry using cobalt as an internal standard. The TXRF detection limit of chlorine was found to be 3.6 pg with sample size of 30 μL. In order to assess the applicability of TXRF method for chlorine determinations in other nuclear materials, one U 3 O 8 trace element standard was also analyzed for chlorine in similar way. The precision of the method was found to be 25% (1 σ) at ng level in most of the cases. (author)

  14. X-ray fluorescence in geology

    International Nuclear Information System (INIS)

    Dutra, C.V.; Gomes, C.B.

    1990-01-01

    This work is about the X-ray fluorescence aplication in geology. It's showing the X-ray origin and excitation. About the instrumentation this work shows the following: X-ray tubes, colimators, analysers crystals, detectors, amplifiers, pulse height selector, and others electronic components. By X-ray fluorescente are done quantitative and qualitative geological analysis and this work shows this analysis and its detection limits. The problems determination is the example. In this work was done yet the comparative analysis of the various instrumental methods in geochemistry. (C.G.) [pt

  15. [Simultaneous determination of multiple elements in airborne particulate samples by X-ray fluorescence spectrometry].

    Science.gov (United States)

    Takada, T; Hitosugi, M; Kadowaki, T; Kudo, M

    1983-07-01

    An energy dispersive X-ray fluorescence spectrometer (EDX) has been applied to determine multielements in the workplace air. The standards for X-ray fluorescence analysis were prepared by the chelate precipitation method on polyvinyl chloride (PVC) membrane filter. And, the specimens were prepared to deposit various metal compounds of different chemical forms by the suspension method on PVC membrane filter, and they were determined with EDX and atomic absorption spectrometer (AAS). The results obtained were as follows. Though there is a difference by each element, an amount less than 3 microgram/cm2 per unit area makes it possible to undergo multielement analysis, that is, is has no influence on fine particle effect (particle size; under 5 microns). Then, effects of the X-ray intensity by different chemical forms are negligible. At the presence the neighboring element and other elements this technique showed greater precision by carrying out on corrective treatment, etc. The coefficient of variation of this technique was in the range of 2.5-6.5% at DDTC-Cu of 0.5-5.0 micrograms/cm2, with the limit of detection for As : 0.002 microgram/cm2, Zn : 0.003 microgram/cm2, Pb : 0.003 microgram/cm2, Cu : 0.004 microgram/cm2, Ni : 0.003 microgram/cm2, Fe : 0.005 microgram/cm2, Mn : 0.008 microgram/cm2, Cr : 0.013 microgram/cm2, respectively. Aerosols collected at the workplace were analyzed with EDX and AAS, and the obtained results showed good agreement with such regression line as y = 1.04 chi + 0.04, the coefficient of correlation being r = 0.995. From these results, this technique was found to be a very excellent method for monitoring of multielements in the workplace air.

  16. The determination of lanthanum and lanthanide elements by means of X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kuelcue, N.

    1982-01-01

    The quantitative analysis of all lanthanide elements (except Pm) was carried out concurrently using X-ray fluorescence analysis. By choice of suitable preparative methods (thin layer samples prepared by pipetting solutions onto filter paper) and use of an internal standard (Sr) it was possible to obtain linear calibration curves up to high concentrations in the solution (85 g/l) and to suppress disturbances caused by absorption and secondary fluorescence. A correction procedure was developed for reflection superimpositions in the L-spectra of the lanthanide elements which, through selection of the most favourable reflections for analysis, permitted concurrent determination of all 14 elements. Main and secondary constitutents can be analysed whereas enrichment is required for trace analysis. Under routine usage the actual limits of detection range from 3 to 17 μg/cm 2 or alternatively 0.3 to 1.7 mg/ml. (orig.) [de

  17. Determination of ultratrace concentrations of uranium and thorium in natural waters by x-ray fluorescence

    International Nuclear Information System (INIS)

    Stewart, J.H. Jr.; Brooksbank, R.D.

    1981-01-01

    An x-ray fluorescence method for the simultaneous determination of uranium and thorium at the less than 1 ppM level in natural waters is described. Uranium and thorium are coprecipitated with an internal standard, yttrium, and incorporated into an iron-aluminum hydroxide carrier. The hydroxide precipitate is filtered, and the filter disk is analyzed by the energy-dispersive x-ray fluorescence technique. Matrix interferences caused by the presence of unpredictable anions and cations are compensated for by the internal standard. The U/Y and Th/Y ratios are linear over the 5- to 100-μg range of interest, and the detection limit of each element on the filter disk is 2 μg (3 sigma). Relative standard deviation was 17% at the 15-μg and 4% at the 100-μg level for thorium and 11% at the 11-μg and 2% at the 100-μg level for uranium. Analysis of spiked solutions showed a recovery of 19.6 +- 0.3 μg for uranium and 19.8 +- 0.3 μg for thorium at the 20-μg level, and the normal lower reporting limit is 5 μg. Fifty disks can be routinely measured during a normal working day

  18. Determination of rubidium and strontium in geological materials by X-Ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Roca, M.

    1979-01-01

    In order to determine whole-rock ages by the Rb/Sr procedure, an X-ray fluorescence spectrometry method for the determination of both elements has been developed. The samples are pressed into boric acid backed and ringed pellets with this material as a binding agent. Matrix corrections are made following the determination od the mass absorption coefficients, based on the intensity of the Compton-scattered peak of MoKα. or MoKβ 1 .3. The U. S. Geological Survey granodiorite GSP-1 is used as a reference standard. Spectral-line interferences have been carefully studied and the empirical correction factors determined. A BASIC language program for calculating the Rb and Sr concentrations and the Rb/Sr ratios has been written. (Author) 7 refs

  19. The determination of trace elements in uranium ores by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De Villiers, W. van Z.

    1983-11-01

    The determination of 17 trace elements (As, Ba, Co, Cr, Cu, Mo, Nb, Ni, Pb, Rb, Sr, Th, U, V, Y, Zn and Zr) in uranium ores by x-ray fluorescence spectrometry was investigated in this study. The determination of major elements was also necessary for the calculation of mass absorption coefficients. Initially a method was developed for the determination of the elements of interest in unmineralised silicates. Correction for absorption of radiation by the sample were made by means of mass absorption coefficients which were obtained from the relation between the inverse of the mass absorption coefficient and the intensity of the Compton scattering peak. The Feather and Willis method was used for determining the background intensity at the peak positions as well as for mass absorption coefficients. It was observed that the background intensity in the region of the uranium lines increases with increasing uranium content of the sample

  20. X-ray fluorescence analyzer arrangement

    International Nuclear Information System (INIS)

    Vatai, Endre; Ando, Laszlo; Gal, Janos.

    1981-01-01

    An x-ray fluorescence analyzer for the quantitative determination of one or more elements of complex samples is reported. The novelties of the invention are the excitation of the samples by x-rays or γ-radiation, the application of a balanced filter pair as energy selector, and the measurement of the current or ion charge of ionization detectors used as sensors. Due to the increased sensitivity and accuracy, the novel design can extend the application fields of x-ray fluorescence analyzers. (A.L.)

  1. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ovari, M.; Streli, C.; Wobrauschek, P.; Zaray, Gy.

    2009-01-01

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  2. Determination of carbon in natural freshwater biofilms with total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovari, M. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)], E-mail: ovari@chem.elte.hu; Streli, C.; Wobrauschek, P. [Atominstitut of the Austrian Universities, TU-Wien, Stadionallee 2, A-1020, Wien (Austria); Zaray, Gy. [Department of Analytical Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary); Cooperative Research Centre of Environmental Chemistry, Eoetvoes University, Budapest, H-1117, Budapest, Pazmany Peter stny. 1/a. (Hungary)

    2009-08-15

    There is a growing interest in determination of low Z elements, i.e., carbon to phosphorus, in biological samples. Total reflection X-ray fluorescence spectrometry (TXRF) has been already established as suitable trace element analytical method with low sample demand and quite good quantification limits. Recently, the determinable element range was extended towards Z = 6 (carbon). Biofilms can be used for biomonioring purposes in the aquatic environment. Besides the trace metals, especially the determination of the carbon content is important for the better understanding of the early stage of biofilm formation. For this, an ATI low Z spectrometer equipped with Cr-anode X-ray tube, multilayer monochromator, vacuum chamber, and a Si(Li) detector with ultra thin window was used. Biofilms were grown on two different artificial supports (granite and plexiglass), freeze dried, suspended in high purity water and analyzed. As an internal standard the natural titanium content of the biofilms was used. The accuracy of the method was checked by total carbon measurement using a combusting carbon analyzer.

  3. Determination of fission products in irradiated fuel by X-ray fluorescence

    International Nuclear Information System (INIS)

    Mogensen, M.; Als-Nielsen, J.; Hessel Andersen, N.

    1986-08-01

    X-ray fluorescence is a well established analytical tool for measuring elemental composition of fairly large (approximately 5 cm 2 ) ''cold'' samples. A version of this technique has been developed for analysis of radial distribution of fission products Xe, Cs and Ba in irradiated UO 2 fuel samples. About 0.1 mm thin slices of fuel pellets (full cross sections) are irradiated by 50 keV X-rays. The intensity of the Xe (Cs, Ba) K α fluorescence radiation generated is measured by means of a Ge detector fitted with a collimator. The slit is 0.5 mm wide in the scanning direction and 2 mm long. The measured Xe K α X-ray intensities are converted to absolute concentrations by comparing to the intensity from a Xe gas standard. In the case of Cs and Ba solid standards may be used. The X-ray fluorescence analysis is compared to other techniques used to obtain radial fission product profiles. It is shown how a combination of X-ray fluorescence and electron probe micro analysis is able to reveal the amount of Xe in the grain boundary porosities. (author)

  4. X-ray fluorescence holography.

    Science.gov (United States)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu, Wen; Matsushita, Tomohiro

    2012-03-07

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy.

  5. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya; Hu Wen; Matsushita, Tomohiro

    2012-01-01

    X-ray fluorescence holography (XFH) is a method of atomic resolution holography which utilizes fluorescing atoms as a wave source or a monitor of the interference field within a crystal sample. It provides three-dimensional atomic images around a specified element and has a range of up to a few nm in real space. Because of this feature, XFH is expected to be used for medium-range local structural analysis, which cannot be performed by x-ray diffraction or x-ray absorption fine structure analysis. In this article, we explain the theory of XFH including solutions to the twin-image problem, an advanced measuring system, and data processing for the reconstruction of atomic images. Then, we briefly introduce our recent applications of this technique to the analysis of local lattice distortions in mixed crystals and nanometer-size clusters appearing in the low-temperature phase of a shape-memory alloy. (topical review)

  6. Use of X-ray fluorescence analysis for the determination of hafnium in zircalloys

    International Nuclear Information System (INIS)

    Sato, I.M.; Salvador, V.L.R.; Lordello, A.R.

    1985-01-01

    The determination of hafnium at trace levels (ppm) in the presence of zirconium by X-ray fluorescence technique is presented. The samples were prepared in the form of double-layer pellets, with boric acid as the binding material. The most sensitive first order line of hafnium HfLα (0.157 nm), which is used analyticaly, has approximately 67% overlapping with second order line of zirconium ZrKα 1 , (0.079 nm). As the excitation potencial of zirconium is larger than hafnium, the best condition was selected, so that the interference of zirconium intensity would not be significant in hafnium analytical line. The method allowed the determination of hafnium above 5.0 ppm (LLd = 1.5 ppm) with an accuracy of less than 10%. (Author) [pt

  7. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vries, J.L. de.

    1976-01-01

    The seventh edition of Philips' Review of Literature on x-ray fluorescence spectrometry starts with a list of conference proceedings on the subject, organised by the Philips organisation at regular intervals in various European countries. It is followed by a list of bulletins. The bibliography is subdivided according to spectra, equipment, applications and absorption analysis

  8. X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ray, N.B.

    1977-01-01

    The principle, instrument and procedure of X-ray fluorescence spectrometry are described. It is a rapid, simple and sensitive method for the trace analysis of elements from sodium to uranium in powder, liquid or metal samples. (M.G.B.)

  9. Determination of 40K radioactivity in the soil using energy dispersive X ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Lu Weiwei; Song Fuxiang; Zeng Liping; Lu Hongning

    2012-01-01

    The 40 K radioactive of' the pressed powder sample was determined by Epsilon 5 high-energy polarized energy dispersive X ray fluorescence (EDXRF) spectrometer. The correlation coefficient of the standard curve method was 0.9910, the precision was 2.98% and the relative deviation of the measurement standard samples was up to 6.40%, which showed that the precision and accuracy of the method were also good. Simultaneous measurement of seven soil samples using this method and γ-spectrometer were carried, the results of two analytical methods were compared using a paired t-test by SPSS program, which showed that there was no significant difference in the two sets of data, P>0.05. It indicated that EDXRF could be a potential simple method for analyzing 40 K radioactive in soil samples. (authors)

  10. Impurities determination in uranium eluates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Bellavigna, Horacio J.; Eppis, Maria R.; Ramella, Jose L.

    1999-01-01

    The chemical control of impurities in nuclear materials is indispensable in order to assure an efficient operation of the reactors. The maximum concentration admitted depends of the elements and in most cases are in the parts per billion range. Conventional analytical methods require a pre-concentration treatment of the sample and a previous separation of the matrix (uranium). This paper investigates the use of the total reflection X-ray fluorescence as an alternative methodology for the determination of impurities in nuclear materials, namely K, Ca, Ti, Cr, Mn, Fe, Ni, Cu and As. The detection limits obtained were in the range of 0.1 to 20 ng/ml for a 1000 seconds counting time. (author)

  11. X-Ray Fluorescence to Determine Zn in Bolivian Children using Hair Samples

    International Nuclear Information System (INIS)

    Tellería Narvaez, C.A.; Fernández Alcázar, S.; Barrientos Zamora, F.G.; Chungara Castro, J.; Luna Lauracia, I.; Mamani Tola, H.; Mita Peralta, E.; Muñoz Gosálvez, A.O.; Romero Bolaños, L.E.; Ramírez Ávila, G.M.

    2014-01-01

    As a first step in the evaluation of nutritional levels in Bolivian children (8–13 years-old), we carried out X-Ray Fluorescence measurements in hair samples of children belonging to different social classes and living either in rural areas or in cities. The aim of this study is to contribute to health policies tending to improve the global health of children and consequently avoid malnutrition. Our method intends to have maximum reliability and at the same time be as simple as possible from an experimental point of view. Additionally, we use this method to determine some other elements such as Fe, Cu, Pb, As and Hg, the latter three considered as contaminants that could be present in children living in areas which neighbor mines and industries. This work will be complemented by some biological and medical tests

  12. Determining sulfur in metallurgical coke by the X-ray fluorescent method

    Energy Technology Data Exchange (ETDEWEB)

    Sofilic, T.; Kesic-Racan, M.; Sindler, M.; Sokolean, D.

    1979-01-01

    A method is described of X-ray fluorescent analysis for current determination of sulfur in the concentration range of 0.5-1.16% in metallurgical coke. To do this, the analyzed material (coke) is ground to a particle size of 200 mu and mixed in a 1:1 ratio with an organic binder (soluble starch). The mixture is briquetted in meshes of a certain size under a pressure of 25 tons/cm/sub 2/. The tablets obtained are analyzed in a Phillips spectrometer with a Cr anticathode. The presence is noted of a linear dependence between the S content and the instrument reading; the correlation factor is 0.91; the mean detection error, 0.0596.

  13. X-Ray Fluorescence to Determine Zn in Bolivian Children using Hair Samples

    Energy Technology Data Exchange (ETDEWEB)

    Tellería Narvaez, C.A.; Fernández Alcázar, S.; Barrientos Zamora, F.G.; Chungara Castro, J.; Luna Lauracia, I.; Mamani Tola, H.; Mita Peralta, E.; Muñoz Gosálvez, A.O. [Centro de Investigaciones y Aplicaciones Nucleares (CIAN-Viacha), Viacha (Bolivia, Plurinational State of); Romero Bolaños, L.E. [Instituto Boliviano de Ciencia y Tecnología Nuclear Av. 6 de Agosto 2905, La Paz (Bolivia, Plurinational State of); Ramírez Ávila, G.M., E-mail: gramirez@ulb.ac.be [Instituto de Investigaciones Físicas, Universidad Mayor de San Andrés, Campus Universitario Cota Cota, Casilla 8635, La Paz (Bolivia, Plurinational State of)

    2014-06-15

    As a first step in the evaluation of nutritional levels in Bolivian children (8–13 years-old), we carried out X-Ray Fluorescence measurements in hair samples of children belonging to different social classes and living either in rural areas or in cities. The aim of this study is to contribute to health policies tending to improve the global health of children and consequently avoid malnutrition. Our method intends to have maximum reliability and at the same time be as simple as possible from an experimental point of view. Additionally, we use this method to determine some other elements such as Fe, Cu, Pb, As and Hg, the latter three considered as contaminants that could be present in children living in areas which neighbor mines and industries. This work will be complemented by some biological and medical tests.

  14. Determination of impurities in magnesium and aluminium by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Roca, M.; Diaz-Guerra, J.P.

    1979-01-01

    The determination of traces of Al, Cr, Cu, Fe, Mn, Ni, Pb, Si and of Bi, Cr, Cu, Fe, Ga, Mg, Mn, Ni, Pb, Si, Sn, Ti, V and Zn in samples of magnesium and aluminium, respectively, by means of X-ray fluorescence spectrometry, are studied. An automatic sequential spectrometer with an on-line computer for the treatment of data has been employed. The most suitable measurement parameters have been chosen for each element in order to achieve detection limits to a few p.p.m. For magnesium in the form of drillings the analyses are performed with satisfactory results for most impurities by pressing the samples into briquettes and employing metallic discs as standards. Correction methods for the spectral interferences of Ti on V, and V on Cr have been applied. (author)

  15. Determination of trace metals in nuclear-grade uranium dioxide by X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Salvador, V.L.R.; Imakuma, K.

    1988-04-01

    A method is described for the simultaneous determination of low concentrations of Ca, Cr, Cu, Fe, Mn and Ni in nuclear-grade uranium dioxide by X-ray fluorescence spectrometry, without the use of chemical treatment. The lower limits of detection range from 2 μg g -1 for nickel and manganese to 5 μg g -1 for copper. Samples are prepared in the form of double-layer pellets with boric acid as a binding agent. Standards are prepared in a U 3 O 8 matrix, which is more chemically stable than UO 2 and has similar matrix behaviour. The correlation coefficients for calibration curves are better than 0.999. Erros range from 2.4 % for chromium to 6.8 % for nickel. (author) [pt

  16. X-Ray Fluorescence Spectrometry. II. Determination of Uranium in ores

    International Nuclear Information System (INIS)

    Bermudez Polonio, J.; Crus Castillo, F. de la; Fernandez Cellini, R.

    1961-01-01

    A method of analysis of uranium in ores by X-ray spectrometry was developed, using the internal standard technique. Strontium was found to be the most suitable internal standard for general use. A Norelco Philips X-ray fluorescent spectrometer was used in this work, equipped with a lithium fluoride crystal acting as a diffraction grating analyzer. The intensity of the uranium-L α 1 spectral line is calculated and related to corresponding strontium-K α spectral line, both detected with a Scintillation Counter. (Author) 31 refs

  17. Optimization of a spectrometry for energy-dispersive x-ray fluorescence analysis by x-ray tube in combination with secondary target for multielements determination of sediment samples

    International Nuclear Information System (INIS)

    Zaidi Embong; Husin Wagiran

    1997-01-01

    The design of an energy-dispersive X-ray fluorescence spectrometer equipped with a conventional X-ray tube and secondary target is described. The spectrometer system constructed in our laboratory consists of a semiconductor detector system, irradiation chamber and X-ray tube. Primary source from X-ray tube was used to produced secondary X-ray from selenium, molybdenum and cadmium targets. The fluorescence X-ray from the sample was detected using Si(Li) detector with resolution of 0. 175 keV (Mn-K(x). The spectrometer was used for determination of multi-elements with atomic number between 20 to 44 in river sediment samples. The X-ray spectrum, from the samples were analysed using computer software which was developed based on Marquardt method. Optimal conditions and detection limits are determined experimentally by variation of excitation parameters for each combination of secondary target and tube voltage

  18. Determination of Fission Products in Irradiated Fuel by X-Ray Fluorescence

    DEFF Research Database (Denmark)

    Mogensen, Mogens Bjerg; Als-Nielsen, Jens Aage; Andersen, Niels Hessel

    X-ray fluorescence i s a well e s t a b l i s h e d analytical tool for measuring elemental composition of fairly large (~ 5 cm2) "cold" samples. A version of t h i s technique has been developed for a n a l y s i s of radial d i s t r i b u t i o n of f i s s i o n products Xe, Cs and Ba...... in the scanning d i rection and 2 mm long. The measured Xe Ko x-ray i n t e n s i t i e s are converted to absolute concentrations by comparing to the intens i t y from a Xe gas standard. In the case of Cs and Ba s o l id standards may be used. The X-ray fluorescence analysis i s compared to other techniques used...... to obtain radial f i s s i o n product profiles, i t i s shown how a combination of X-ray fluorescence and electron probe micro a n a l y s i s i s able to reveal the amount of Xe in the grain boundary porosities....

  19. X-ray emission spectroscopy. X-ray fluorescence

    International Nuclear Information System (INIS)

    Despujols, J.

    1992-01-01

    Principles of X-ray emission spectrometry are first recalled, then wave-length dispersive and energy dispersive X-ray fluorescence spectrometer are described. They are essentially designed for qualitative and quantitative analysis of elements (Z>10). Sample preparation, calibration, corrections, interferences, accuracy are reviewed. Examples of use in different industries are given. (71 refs.)

  20. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  1. Determination of non-ionic surfactants in technologic liquors and effluents by X-ray fluorescent spectrometry

    International Nuclear Information System (INIS)

    Dankowski, P.; Majda, J.

    1977-01-01

    The method has been worked out for determination of non-ionic surfactants in technological liquors and effluents, based on the X-ray fluorescent spectrometry with an initial concentration by means of the phosphomolybdic acid. The method is suitable for a quantitative determination of ethylene oxide adducts in a wide range of applicable concentrations, the trace-ones included. (M.Z.)

  2. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-01-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples

  3. Application of the Total Reflection X-ray Fluorescence technique to trace elements determination in tobacco

    Science.gov (United States)

    Martinez, T.; Lartigue, J.; Zarazua, G.; Avila-Perez, P.; Navarrete, M.; Tejeda, S.

    2008-12-01

    Many studies have identified an important number of toxic elements along with organic carcinogen molecules and radioactive isotopes in tobacco. In this work we have analyzed by Total Reflection X-Ray Fluorescence 9 brands of cigarettes being manufactured and distributed in the Mexican market. Two National Institute of Standards and Technology standards and a blank were equally treated at the same time. Results show the presence of some toxic elements such as Pb and Ni. These results are compared with available data for some foreign brands, while their implications for health are discussed. It can be confirmed that the Total Reflection X-Ray Fluorescence method provides precise (reproducible) and accuracy (trueness) data for 15 elements concentration in tobacco samples.

  4. Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Racz, L.; Bumbalova, A.; Harangozo, M.; Toelgyessy, J.; Tomecek, O.

    2000-01-01

    Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

  5. Determination of multi-element profiles of soil using energy dispersive X-ray fluorescence (EDXRF)

    International Nuclear Information System (INIS)

    Yu, K.N.; Yeung, Z.L.L.; Lee, L.Y.L.; Stokes, M.J.; Kwok, R.C.W.

    2002-01-01

    The source profile for soil in Hong Kong is important both for determination of the main air pollutant source in Hong Kong and for assessment of the impact of Asian dust storms on Hong Kong. Soil associated with different rock types have been sampled, and the concentrations of 19 chemical elements, Na, Al, Si, Ti, V, Cr, Mn, Fe, Co, K, Ca, Ni, Cu, Zn, Pb, Rb, Sr, Y and Zr, have been determined using energy dispersive X-ray fluorescence. A profile for the average soil for Hong Kong has been determined by taking average values for the different soil categories. The values for the Hong Kong soil are commensurate with values for rural soil derived by other workers, except that Hong Kong soil has much lower Fe and Ca concentrations. The abundance of Al, Ca and Fe in the average Hong Kong soil are 9.23%, 0.11% and 0.85%. We conclude that Ca provides a good marker element for identifying dust episodes in Hong Kong while Al does not

  6. Thorium determination by x-ray fluorescence spectrometry in simulated thorex process solutions

    International Nuclear Information System (INIS)

    Yamaura, M.; Matsuda, H.T.

    1991-11-01

    The X-ray fluorescence method for thorium determination in aqueous and organic (TBP/n-dodecane) solutions is described. The thin film technique for sample preparation and a suitable internal standard had been used. The best conditions for Thorium determination had been established studying some parameters as analytical line, internal standard, filter paper, paper geometry, sample volume and measurement conditions. With the established conditions, thorium was concentration range of to 200 g Th/L and in organic solutions (2-63g Th/L) with 1,5% of precision. The accuracy of the proposed method was 3% in aqueous and organic phases. The detection limit was 1,2μg thorium for aqueous solutions and 1,4μg for organic solutions. Uranium, fission products, corrosion products and Thorex reagent components were studied as interfering elements in the thorium analysis. The matrix effect was also studied using the Thorex process simulated solutions. Finally, the method was applied to thorium determination in irradiated thorium solutions with satisfactory results. (author)

  7. Determination of Ca/P molar ratio in hydroxyapatite (HA) by X-ray fluorescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Scapin, Marcos A.; Guilhen, Sabine N.; Cotrim, Marycel E.B.; Pires, Maria Ap. F., E-mail: mascapin@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Hydroxyapatite (HA) is a mineral composed of calcium phosphate employed for endodontics, restorative dentistry and other applications in orthopedics and prosthesis. Additionally, this biomaterial is an inexpensive but efficient adsorbent for the removal of heavy metals and other unwanted species of contaminated liquid effluents. This is especially interesting when low-cost effective remediation is required. A Ca / P molar ratio of 1.667 is consistent with the theoretical Ca / P ratio for calcium hydroxyapatite with a compositional formula of Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}, which properties are well discussed in the literature. The aim of this work was to implement and validate a methodology for simultaneous determination of major and minor constituents in the hydroxyapatite (HA) as well as providing the Ca / P molar ratio. To accomplish these achievements, wavelength dispersive X-ray fluorescence spectroscopy (WDXRF) was applied. This is a non-destructive technique that requires no chemical treatment, enabling fast chemical analysis in a wide variety of samples, with no hazardous waste being generated as a result of the process of determination. A standard reference material from NIST (SRM 1400 – Bone Ash) was used to validate the methodology for the determination of magnesium, phosphorus, potassium, calcium, iron, zinc, strontium and the Ca / P ratio in HA samples by WDXRF. The Z-score test was applied as a statistical tool and showed that the calculated values were of less than 1.8 for all the measured analytes. (author)

  8. Determination of Ca/P molar ratio in hydroxyapatite (HA) by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Scapin, Marcos A.; Guilhen, Sabine N.; Cotrim, Marycel E.B.; Pires, Maria Ap. F.

    2015-01-01

    Hydroxyapatite (HA) is a mineral composed of calcium phosphate employed for endodontics, restorative dentistry and other applications in orthopedics and prosthesis. Additionally, this biomaterial is an inexpensive but efficient adsorbent for the removal of heavy metals and other unwanted species of contaminated liquid effluents. This is especially interesting when low-cost effective remediation is required. A Ca / P molar ratio of 1.667 is consistent with the theoretical Ca / P ratio for calcium hydroxyapatite with a compositional formula of Ca 10 (PO 4 ) 6 (OH) 2 , which properties are well discussed in the literature. The aim of this work was to implement and validate a methodology for simultaneous determination of major and minor constituents in the hydroxyapatite (HA) as well as providing the Ca / P molar ratio. To accomplish these achievements, wavelength dispersive X-ray fluorescence spectroscopy (WDXRF) was applied. This is a non-destructive technique that requires no chemical treatment, enabling fast chemical analysis in a wide variety of samples, with no hazardous waste being generated as a result of the process of determination. A standard reference material from NIST (SRM 1400 – Bone Ash) was used to validate the methodology for the determination of magnesium, phosphorus, potassium, calcium, iron, zinc, strontium and the Ca / P ratio in HA samples by WDXRF. The Z-score test was applied as a statistical tool and showed that the calculated values were of less than 1.8 for all the measured analytes. (author)

  9. Silver content determination in mining and ore dressing using radionuclide-excited X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Koerner, B.; George, R.; Ratnikow, W.

    1989-01-01

    A laborsaving method based on radionuclide-excited X-ray fluorescence is described for the determination of silver in mining and ore dressing. Detection limits reached under operation conditions and measuring errors are discussed and compared with results from chemical analyses

  10. Characterization of airborne particulate matter in Santiago, Chile. Part 5: non-destructive determination by x-ray fluorescence

    International Nuclear Information System (INIS)

    Poblete, V.H.; Hurtado, O.; Toro, P.

    1995-01-01

    A procedure for non-destructive analysis of airborne particular matter using X ray fluorescence is presented. The elements Fe, Pb and Zn were determined and their concentration compared with the results reported by other techniques. The homogeneity of the distribution of Fe in the samples was investigated. (author). 4 refs, 5 figs

  11. Moessbauer spectroscopy and X-ray fluorescence analysis in studies for determinate the sources of several prehispanic objects

    International Nuclear Information System (INIS)

    Arriola S, H.; Ramos R, P.; Castro V, P.; Jimenez R, A.; Flores D, F.; Garcia Moreno C, C.

    1980-01-01

    A study by the Moessbauer effect and X-ray fluorescence analysis of the mexican prehispanic ceramic specimens is presented. Several iron compounds of the ceramics are determined, the different iron compounds indicate different sources of the clays, and different forms of ovens used with them, this compounds are identified by the differents oxidation states of the magnetic iron Fe 3+ , Fe 2+ . (author)

  12. Determination of trace elements and heavy metals in sediment using x-ray fluorescence

    International Nuclear Information System (INIS)

    Sidahmed, Muataz Ahmed Ibrahem

    2014-01-01

    In this study, 30 sediment samples were taken randomly from the area of Suba south of Khartoum state. Trace elements and heavy metal were determined in sediments samples using x-ray fluoresce spectroscopy (X RF). K, Ca, Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, and Zr were determined by X RF. Standard Reference Material (SRM) from international Atomic Energy Agency (IAEA-Soil-7) has been used to achieve accuracy of X RF method. Measured values were found in agreements with certified values. The average elemental concentrations of K, Ca, Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, and Zr were 5882.7, 20703.3, 6264.3, 460.97, 26713.3, 7.7, 43.4, 18.6, 28.6, 144.8, and 173.06, respectively. Correlation between elements was performed also cluster analysis was used to check the similarly between the samples result. The result of study were compared with previous studies and the concentrations of some elements found to be similar.(Author)

  13. Determination of uranium and thorium by X-ray fluorescence analysis in ores and derivatives

    International Nuclear Information System (INIS)

    Sato, I.M.

    1979-01-01

    A method to determinate the elements thorium and uranium by X-rays fluorescence in ores and derivatives is presented. The chosen samples are ores from Morro do Agostinho, Pocos de Caldas, Minas Gerais and monazite concentrated from Nucleomon which has the feature of being complex, and which is a type of material frequently found in nuclear technology. The method of fusion is chosen to prepare the samples, in which they are fused in borax in its natural form thus, proposing analyses of those elements without any previous chemical treatment. In the analyses of uranium, the effect of absorption of iron existing in the distinctive line ULα (n=2) of second order is mathematically corrected, instead of baing eliminated by chemical separation. The determination of thorium is made through the method of double-dilution in which several reasons have shown the advantages of its employment. The precision in function the coefficient of variation in percentage and the accuracy of the method proposed are discussed [pt

  14. The determination of molybdenum and tungsten in resin by x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Eddy, B.T.

    1985-01-01

    This report describes a method using X-ray-fluorescence spectrometry for the determination of molybdenum and tungsten in ion-exchange resins. The dried resin is milled with sand, binder, and an internal-standard mixture before being briquetted. Niobium and zinc are used as the internal standards for molybdenum and tungsten respectively. Intensity measurements are made with the gold anode tube. Corrections are made for the interference of the Mo Kα analytical line on the background intensities used for the Mo Kα and Nb Kα lines. The precision of the analysis for molybdenum ranges from a relative standard deviation 0,02 at 5 mg/g to 0.045 at 55μg/g; for tungsten, the relative standard deviation ranges from 0,04 at 5 mg/g to 0,055 at 55μg/g. The limits of determination in the original resin sample were found to be 40μg/g for molybdenum and 80μg/g for tungsten. The laboratory method is given in an appendix

  15. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    Energy Technology Data Exchange (ETDEWEB)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J., E-mail: rc.nardes@gmail.com, E-mail: ramonziosp@yahoo.com.br, E-mail: francissanches@gmail.com, E-mail: hamiltongamafilho@hotmail.com, E-mail: davi.oliveira@uerj.br, E-mail: marcelin@uerj.br [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Instituto de Fisica. Departamento de Fisica Aplicada e Termodinamica

    2015-07-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  16. Determination of metals in air samples using X-Ray fluorescence associated the APDC preconcentration technique

    International Nuclear Information System (INIS)

    Nardes, Raysa C.; Santos, Ramon S.; Sanches, Francis A.C.R.A.; Gama Filho, Hamilton S.; Oliveira, Davi F.; Anjos, Marcelino J.

    2015-01-01

    Air pollution has become one of the leading quality degradation factors of life for people in large urban centers. Studies indicate that the suspended particulate matter in the atmosphere is directly associated with risks to public health, in addition, it can cause damage to fauna, flora and public / cultural patrimonies. The inhalable particulate materials can cause the emergence and / or worsening of chronic diseases related to respiratory system and other diseases, such as reduced physical strength. In this study, we propose a new method to measure the concentration of total suspended particulate matter (TSP) in the air using an impinger as an air cleaning apparatus, preconcentration with APDC and Total Reflection X-ray Fluorescence technique (TXRF) to analyze the heavy metals present in the air. The samples were collected from five random points in the city of Rio de Janeiro/Brazil. Analyses of TXRF were performed at the Brazilian Synchrotron Light Laboratory (LNLS). The technique proved viable because it was able to detect five important metallic elements to environmental studies: Cr, Fe, Ni, Cu and Zn. This technique presented substantial efficiency in determining the elementary concentration of air pollutants, in addition to low cost. It can be concluded that the metals analysis technique in air samples using an impinger as sample collection instrument associated with a complexing agent (APDC) was viable because it is a low-cost technique, moreover, it was possible the detection of five important metal elements in environmental studies associated with industrial emissions and urban traffic. (author)

  17. Quantitative determination of Sulfur and Chlorine in Crude Oils by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Ayala Jimenez, R.E.

    1986-01-01

    Given the importance of sulfur and chlorine content in crude petroleum, and that the actual methods used in the country to its determination are slow and cumbersome, the present work consisted in applying a new method, based on X-ray fluorescence spectrometry, to make this analysis as fast as possible with greater sensibility and precision. Samples of crude petroleum were analyzed using two different quantitative methods: a) through calibration curves elaborated with standard aqueous solutions of inorganic salts of S and Cl and b) through standard addition method using CS 2 as standard for S and CCl 4 for Cl. The measuring system consisted of Fe-55 radioactive source (10 mCi), Si-Li semiconductor detector, spectrum amplifier, multichannel analyzer and a DIGITAL Computer. The peak areas and their deviations were obtained through AXIL software. The values of area and deviation joined to weight of sample and amount of standard added were used to calculate the concentration of the analite and its deviation. In conclusion, calibration curves enable only semiquantitative analysis. However, the standard addition method has advantages over ASTM methods D 129-64 and D 808-63 for sulfur and chlorine respectively. The main advantage is the great speed with which an analysis is made: 20 minutes, while ASTM methods need approximately 16 hours. Likewise it was obtained: sensibility 0.05%; accuracy: maximum 0.02%, minimum 10%; and precision: maximum 2%, minimum 10%. (author)

  18. Methodology for determination of inorganic elements in vitamin supplements by X-ray fluorescence

    International Nuclear Information System (INIS)

    Endo, Lucas Y.; Portezan Filho, Otavio; Perreira, Paulo S.; Lopes, Fabio; Appoloni, Carlos R.; Melquiades, Fabio L.

    2009-01-01

    A methodology is present for qualification of inorganic elements in alimentary supplements, using a portable system of low power X-ray, in the analysis of two commercial products, both found as pills. The PXRF (Portable X-ray Fluorescence) is a X-ray mini tube, Ag filter at tube exit, a Si-Pin semiconductor and a Ag collimator at the detector entry, specific circuitry for this type of system and a microcomputer for the data acquisition and analysis. Samples and standards were diluted in boric acid, and the samples were prepared in a 1:10 rate, and the standards vary of 1:2, 1;5, 1:10. 1:15 and 1:100. Results were obtained for Ca, Ti, Mn, Fe, Cu e Zn, with values varying from 0.14 to 8.45 for the sample A, and from 0.17 to 17.94 for the sample B. The PXRF portable system demonstrated to be a multi elementary analysis tool with high analytical speed, and can be applied in situ no only for quality control but also for monitoring of inspection organism

  19. Extraction X-ray fluorescence determination of gold in natural samples

    International Nuclear Information System (INIS)

    Dmitriev, S.N.; Shishkina, T.V.; Zhuravleva, E.L.; Chimehg, Zh.

    1990-01-01

    The behaviour of gold and other elements impeding its X-ray fluorescence (XRF) determination, namely, of zinc, lead, and arsenic, has been studied during their extraction by TBP from hydrochloric, nitric, and aqua regia solutions using solid extractant (SE(TBP)). Gold extraction from pulps after aqua regia leaching, with the gold distribution coefficient (D) being equal to about 10 4 , was observed as the most favourable one for the quantitative and selective recovery of gold. For extraction from hydrochloric solutions the D Au value does not depend on the gold content of initial solutions (10 -8 - 10 -4 M), but it decreases substantially with increasing extraction temperature (from 5x10 5 at 20 deg C to 9x10 3 at 70 deg C). An anomalously high distribution coefficient of lead (D Pb =10 3 ) was observed during extraction from hydrochloric solutions in the presence of chlorine. This fact could be explained by the formation of the chlorocomplexes of lead (IV). The XRF method of gold determination in natural samples has been developed, which includes the aqua regia decomposition of the samples, recovery of gold from the pulp after its leaching by SE(TBP) and back - extraction using a 0.025 M hot thiourea solution providing a thin sample film for secondary XRF spectrometry. For 25 g of the sample material the limit of determination is set at 0.01 g per ton (10 -6 %). The accuracy of the technique has been checked on different reference materials. The results agree within 10%. 16 refs.; 5 figs.; 1 tab

  20. Determination of heavy metals in Damascus drinking water using total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Bakraji, E. H.; Karajo, J.

    2000-01-01

    Total reflection x-ray fluorescence spectrometry and chemical preconcentration have applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 μg/l. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines. (author)

  1. Capacity of X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wobrauschek, P.; Kregsamer, P.

    1997-01-01

    X-Ray fluorescence analysis (XRF) is a powerful analytical tool for the qualitative and quantitative determination of chemical elements in a sample. Two different detection principles are accepted widely: wavelength dispersive and energy dispersive. Various sources for XRF are discussed: X-ray tubes, accelerators for particle induced XRF, radioactive isotopes, and the use of synchrotron radiation. Applications include environmental, technical, medical, fine art, and forensic studies. Due to the demands of research and application special techniques like total reflection XRF (TXRF) were developed with ultimately achievable detection limits in the femtogram region. The elements detectable by XRF range from Be to U. (author)

  2. Cr and Yb markers determination in animal feces by energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Almeida, Eduardo de; Senicato, Luis A; Nascimento Filho, Virgilio F.; Gomide, Catarina A.

    2007-01-01

    Chromium and Ytterbium elements are utilized in animal nutritional studies as markers. This paper describes an analytical method for Cr and Yb determination in solid buffalo feces sample using standard addition method and energy dispersive X-ray spectrometry (EDXRF) technique. One gram dried sample was pressed manually in an XRF sample cup with Mylar film (6.3 μm thickness) in the bottom. The experimental conditions were: Mo target X-ray tube with Zr filter, operated at 25 kV/10 mA, and 500 s of acquisition time. The limits of detection for Cr and Yb were 16.6 and 11.4 mg/kg, respectively. This methodology has showed appropriated for simultaneous Cr and Yb determination as marker in animal feces. (author)

  3. Cr and Yb markers determination in animal feces by energy dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Eduardo de; Senicato, Luis A; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear (LIN)]. E-mail: edualm@usp.br; Gomide, Catarina A. [Universidade de Sao Paulo (USP), Pirassununga, SP (Brazil). Faculdade de Zootecnia e Engenharia de Alimentos (FZEA). Dept. de Zootecnia]. E-mail: cbgomide@usp.br

    2007-07-01

    Chromium and Ytterbium elements are utilized in animal nutritional studies as markers. This paper describes an analytical method for Cr and Yb determination in solid buffalo feces sample using standard addition method and energy dispersive X-ray spectrometry (EDXRF) technique. One gram dried sample was pressed manually in an XRF sample cup with Mylar film (6.3 {mu}m thickness) in the bottom. The experimental conditions were: Mo target X-ray tube with Zr filter, operated at 25 kV/10 mA, and 500 s of acquisition time. The limits of detection for Cr and Yb were 16.6 and 11.4 mg/kg, respectively. This methodology has showed appropriated for simultaneous Cr and Yb determination as marker in animal feces. (author)

  4. Applications of X-ray fluorescence holography to determine local lattice distortions

    International Nuclear Information System (INIS)

    Hayashi, Kouichi; Happo, Naohisa; Hosokawa, Shinya

    2014-01-01

    Highlights: • We summarized topics of X-ray fluorescence holography focused on the local lattice distortions. • We found details of behaviors of nearest neighbor atoms around dopants. • We found the average distributions of the atoms at the individual sites in mixed crystals. • Distorted and undistorted sires sometimes coexist in a same mixed crystal. - Abstract: X-ray fluorescence holography (XFH) is a method for investigating atomic order up to the medium ranges, and can provide 3D atomic images around specific elements within a radius of nm order. In addition to these characteristics, XFH is sensitive to positional fluctuations of atoms, and therefore it is useful for characterizing the local lattice distortions around specific elements. We have applied XFH to dopants and mixed crystals. We found interesting features in local lattice distortions, such as the displacements of first-neighbor atoms around dopants, far-sighted views of the atomistic fluctuations in mixed crystals, and the coexistence of distorted/undistorted sites in the same material

  5. X-ray Fluorescence Holography: Principles, Apparatus, and Applications

    Science.gov (United States)

    Hayashi, Kouichi; Korecki, Pawel

    2018-06-01

    X-ray fluorescence holography (XFH) is an atomic structure determination technique that combines the capabilities of X-ray diffraction and X-ray fluorescence spectroscopy. It provides a unique means of gaining fully three-dimensional information about the local atomic structure and lattice site positions of selected elements inside compound samples. In this work, we discuss experimental and theoretical aspects that are essential for the efficient recording and analysis of X-ray fluorescence holograms and review the most recent advances in XFH. We describe experiments performed with brilliant synchrotron radiation as well as with tabletop setups that employ conventional X-ray tubes.

  6. X-Ray Fluorescence Spectrometry. I. Determination of thorium in ores

    International Nuclear Information System (INIS)

    Bermudez Polonio, J.; Crus Castillo, F. de la; Fernandez Cellini, R.

    1961-01-01

    A X-ray spectrometric method has been developed for analysis of thorium in ores in the range of concentration from 0.01 to 0.5 percent ThO 2 , using selenium as a internal standard. The concentration of thorium is determined in a working curve prepared by plotting the percentage of ThO 2 against the ratio intensity of the Th Lα 1 line to Sek β 1 line. (Author) 17 refs

  7. The application of X-ray fluorescence (XRF) method for the determination chemical composition of glass bath raw materials

    International Nuclear Information System (INIS)

    Werfel, Z.

    1974-01-01

    The estimation of determination accuracy of glass sand, limestone and dolomite compositions by the means of X-ray fluorescence method has been made. The most important advantage of XRF method application is short time of analysis. The preparation time of sample is not longer than 20 minutes, the analysis of single sample is about 1,5 minutes. The comparison of results of determinations by the means of XRF and complexometric methods have been given. (author)

  8. Determination of zinc in ammoniacal ore leaching solutions by X-ray fluorescence spectrometry using a radioactive source

    International Nuclear Information System (INIS)

    Cornejo, N.; Afailal, A.; Garcia, F.; Palacios, M.

    1994-01-01

    A method was developed for the fast determination of zinc in leaching solutions by radioisotope energy-dispersive X-ray fluorescence (EDXRF) spectrometry. The measured intensities were used to develop regression models for estimating the zinc concentration. The primary radiation was provided by the 244 Cm radioisotope. Several experimental parameters including the saturation thickness and detection limit were determined. The advantages of the utilization of conditioning agents with elements of low atomic number such as nitric acid were established. (orig.)

  9. Co marker determination in rumen liquid sample by energy dispersive X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Eduardo de; Nascimento Filho, Virgilio F.; Massoni, Paulo R. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear (LIN)]. E-mail: edualm@usp.br; Leite, Laudi C.; Lanna, Dante P.D. [Escola Superior de Agricultura ' Luiz de Queiroz' (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Zootecnia. Lab. de Anatomia e Fisiologia Animal (LAFA)]. E-mail: lcleite@ciagri.usp.br

    2007-07-01

    The Co element is used in nutritional studies as marker. This paper describes an analytical methodology for Co determination in rumen liquid sample using energy dispersive X-ray spectrometry (EDXRF). 200 {mu}L of the sample were dried at 60 deg C on 6.35 {mu}m Mylar film. Ga was used as internal standard. The excitation was carried out utilizing Mo target X-ray tube (Zr filter) at 30 kV / 20 mA. The acquisition time was 200 s. The accuracy of this methodology was assessed through standard addition method, the recovery obtained was 98.7 % for Co. The detection limit was 0.15 mg / L for this element. (author)

  10. Co marker determination in rumen liquid sample by energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Almeida, Eduardo de; Nascimento Filho, Virgilio F.; Massoni, Paulo R.; Leite, Laudi C.; Lanna, Dante P.D.

    2007-01-01

    The Co element is used in nutritional studies as marker. This paper describes an analytical methodology for Co determination in rumen liquid sample using energy dispersive X-ray spectrometry (EDXRF). 200 μL of the sample were dried at 60 deg C on 6.35 μm Mylar film. Ga was used as internal standard. The excitation was carried out utilizing Mo target X-ray tube (Zr filter) at 30 kV / 20 mA. The acquisition time was 200 s. The accuracy of this methodology was assessed through standard addition method, the recovery obtained was 98.7 % for Co. The detection limit was 0.15 mg / L for this element. (author)

  11. Determination of trace elements in tea by wavelength dispersive X-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gong Chunhui; Zeng Guoqiang; Ge Liangquan; Li Jun; Wen Ziqiang

    2013-01-01

    Background: Measuring trace elements in tea can determine its nutritional value, verify the authenticity and place of origin, and detect the poisonous and harmful elements remaining in tea due to the application of chemical fertilizers and pesticides. Purpose: In order to reduce the time for sample preparation and the costs of equipment maintenance, wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy was used to determine the trace elements in tea which is rapid, non-destructive and accurate. The contents of more than 20 elements can be measured simultaneously. Methods: Sample pieces were made by the sample preparation method of boric acid rebasing. To avoid the exogenous environmental pollution subjected in the growth of tea, we removed the residual dust of the tea by cleaning it. According to the principle that the standard samples should be similar types with the samples to be analyzed to select standard samples. The curves were built by SuperQ, which contained compiling the measurement conditions, establishing the measurement conditions, checking the angles, determining the measurement times, checking PHD and adding the contents and the names of sample pieces. The accuracy of the method can be obtained by comparing the measured values with the trace element contents of standard samples. The contents of trace elements in tea determined by WDXRF can be used to classify the tea attribution and the tea species through cluster analysis of SPSS software. Results: (1) The results show that the biggest relative standard deviation is 0.43% of Pb, and the precision is very good. (2) Five kinds of tea are taken separately in Fujian and Yunnan, measured three times with the established working curves. And tree diagram of cluster analysis can be obtained with SPSS software to analyze the measured average values with cluster analysis, coupling method between groups and Minkowski distance measurement techniques. It can be seen that in the tree diagram, when the

  12. On stream radioisotope X-ray fluorescence analyser and a method for the determination of copper in slurry

    International Nuclear Information System (INIS)

    Holynska, B.; Lankosz, M.; Lacki, E.; Ostachowicz, J.; Baran, W.; Owsiak, T.

    1975-01-01

    The paper presents an ''on stream'' analyser and a radioisotope X-ray fluorescence method for the continuous determination of copper content in feed 0.5-2.5% Cu, concentrates 15-25% Cu and tailings 0.01-0.03% Cu. The analyser consists essentially of a radioisotope X-ray fluorescence measuring head, γ-density gauge, electronic unit, analog processor and recorders. The method is based on the measurement of the characteristic radiation of Cu series, selected by nickel-cobalt filters. The total relative error (1s) of the determination of copper in feed is 6-8%, in concentrates 5-7% and in tailings about 18%. The ''on stream'' analyser has been succesfully operated in a pilot plant. (author)

  13. Determination of solid surface composition by the X-ray fluorescence method under total external reflection with angular scanning

    International Nuclear Information System (INIS)

    Krasnolutskij, V.P.

    2000-01-01

    Possibilities of determination of composition of surface layers by X-ray fluorescence analysis under total reflection of incident radiation with angular scanning of a target are investigated. For the case of the GaAs target it is shown that the sensibility of this method is sufficient for a control of element composition in layer of thickness 1 nm. A simple method for solution of inverse task of analysis of a two component medium is considered [ru

  14. Determination of nickel in chloralkali electrolysis brines by X-ray fluorescence spectrometry on a membrane filter

    International Nuclear Information System (INIS)

    Andrade, L.L.; Minzl, E.

    1984-01-01

    X-ray fluorescence spectrometry after ammonium pyrrolidinedithiocarbamate (APDC) preconcentration is proposed for the determination of nickel in chloralkali electrolysis brines. The optimum conditions for the precipitation target tube, peak intensity, background, analysing crystal, counters and exposure time were investigated. The method was applied to chloralkali brines of evaporite salts (halite, sylvinite, carnallite and tachhydrite), sodium, potassium and magnesium salts, explored in Sergipe (Brazil), by Petrobras-Mineracao S.A.(Author) [pt

  15. Determination of gold accumulation in human tissues caused by gold therapy using x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Bacso, J.; Uzonyi, I.; Dezsoe, B.

    1986-08-01

    Human autopsy tissues from five patients with rheumatoid arthritis treated earlier with aqueous solution of gold and those from untreated control with the same disease were analyzed by x-ray fluorescence spectrometry using a conventional Si(Li) detection system. The gold and zinc concentrations of tissues were determined and compared with literature data. Correlation was found between Zn and Au concentrations in heart, lung, kidney and liver tissues. (author)

  16. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Vives, Ana Elisa Sirito de

    2005-01-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g -1 (Rb), respectively. (author)

  17. Metals determination in coffee sample by total reflection X-ray fluorescence analysis (TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: Silvana@fec.unicamp.br; Brienza, Sandra Maria Boscolo [ Universidade Metodista de Piracicaba (UNIMEP), Piracicaba, SP (Brazil). Faculdade de Ciencias Matematicas, da Natureza e de Tecnologia da Informacao]. E-mail: sbrienza@unimep.br; Zucchi, Orgheda Luiza Araujo Domingues [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas]. E-mail: olzucchi@fcfrp.usp.br; Nascimento Filho, Virgilio Franco do [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: virgilio@cena.usp.br

    2005-07-01

    The objective of this study was to evaluate the inorganic concentration in five brands of coffee, three of them nationally marketed and the others of an exportation kind. The samples were prepared by infusion with deionized water. To carry out the calibration, standard solutions were prepared with different concentrations of Al, Si, K, Ca, Ti, Cr, Fe, Ni, Zn and Se. The measurements were carried out using a white beam of synchrotron radiation for excitation and a Si (Li) semiconductor detector for detection. By employing Synchrotron Radiation Total Reflection X-Ray Fluorescence Analysis (SR-TXRF) it was possible to evaluate the concentrations of P, S, Cl, K, Ca, Mn, Fe, Cu, Zn, Rb and Ba. The detection limits for 300 s counting time were in the range of 0.03 (Ca) to 30 ng.g{sup -1} (Rb), respectively. (author)

  18. X-Ray Fluorescence Determination of the Surface Density of Chromium Nanolayers

    Science.gov (United States)

    Mashin, N. I.; Chernjaeva, E. A.; Tumanova, A. N.; Ershov, A. A.

    2014-01-01

    An auxiliary system consisting of thin-film layers of chromium deposited on a polymer film substrate is used to construct calibration curves for the relative intensities of the K α lines of chromium on bulk substrates of different elements as functions of the chromium surface density in the reference samples. Correction coefficients are calculated to take into account the absorption of primary radiation from an x-ray tube and analytical lines of the constituent elements of the substrate. A method is developed for determining the surface density of thin films of chromium when test and calibration samples are deposited on substrates of different materials.

  19. Energy dispersive X-ray fluorescence determination of cadmium in uranium matrix using Cd Kα line excited by continuum

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Aggarwal, S.K.; Venugopal, V.

    2010-01-01

    An energy dispersive X-ray fluorescence method for determination of cadmium (Cd) in uranium (U) matrix using continuum source of excitation was developed. Calibration and sample solutions of cadmium, with and without uranium were prepared by mixing different volumes of standard solutions of cadmium and uranyl nitrate, both prepared in suprapure nitric acid. The concentration of Cd in calibration solutions and samples was in the range of 6 to 90 μg/mL whereas the concentration of Cd with respect to U ranged from 90 to 700 μg/g of U. From the calibration solutions and samples containing uranium, the major matrix uranium was selectively extracted using 30% tri-n-butyl phosphate in dodecane. Fixed volumes (1.5 mL) of aqueous phases thus obtained were taken directly in specially designed in-house fabricated leak proof Perspex sample cells for the energy dispersive X-ray fluorescence measurements and calibration plots were made by plotting Cd Kα intensity against respective Cd concentration. For the calibration solutions not having uranium, the energy dispersive X-ray fluorescence spectra were measured without any extraction and Cd calibration plots were made accordingly. The results obtained showed a precision of 2% (1σ) and the results deviated from the expected values by < 4% on average.

  20. Cu,Cr and As determination in preserved woods (Eucalyptus ssp.) by X-ray fluorescence spectrometries

    International Nuclear Information System (INIS)

    Pereira Junior, Sergio Matias

    2014-01-01

    Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined. (author)

  1. Determination of trace element levels in leaves of Nerium oleander using X-Ray Fluorescence

    International Nuclear Information System (INIS)

    Santos, Ramon S.; Sanches, Francis A.C.R.A.; Neves, Arthur O.P.; Oliveira, Luis F.; Oliveira, Davi F.; Anjos, Marcelino J.

    2013-01-01

    The environmental pollution by human activity has been one of the most concerns in the last years, principally due to rapid urban growth in the cities and the industrialization process. The air pollution can be increased due to several different kinds of emissions: urban traffic, industrial activities, burning fuel, civil industry of construction/demolition, fires and natural phenomena. Many of these emissions move from long distances due to convections currents and finally tend to deposit mainly in the plants leaves and in the soil. Thus, the plants leaves works as a natural sampler by the emissions deposit in these ones. In this study Nerium oleander leaves were used to measure the environmental pollutions levels in different sampling urban regions in the city of Rio de Janeiro/RJ: Andarai, Benfica, Bonsucesso, Caju, Engenho de Dentro, Engenho Novo, Estacio, Grajau, Inhauma, Lins, Maracana, Maria da Graca, Meier, Praca da Bandeira, Riachuelo, Rio Comprido, Sao Cristovao, Tijuca, Vila Isabel and city Center. The control samples were collected in Campo Grande near of Parque Nacional da Pedra Branca/RJ (National Park of Pedra Branca/RJ). The leaves were collected from adult plants and after the collection the samples were cleaned and placed in the greenhouse for drying, then were mashed and pressed into tablets forms. The analyses were performed using the energy dispersion X-ray fluorescence (EDXRF), developed on the own laboratory and based in a SiPIN detector and a mini X ray tube. It was possible to detect 16 elements in the analyzed samples: K, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb. The results shows that, in the studied areas, the analysis of the Nerium oleander plant shows a low-cost option and with a substantial efficiency as an environmental pollution biomonitor. (author)

  2. Determination of trace element levels in leaves of Nerium oleander using X-Ray Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Ramon S.; Sanches, Francis A.C.R.A.; Neves, Arthur O.P.; Oliveira, Luis F.; Oliveira, Davi F.; Anjos, Marcelino J. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica Armando Dias Tavares. Dept. de Fisica Aplicada e Termodinamica

    2013-07-01

    The environmental pollution by human activity has been one of the most concerns in the last years, principally due to rapid urban growth in the cities and the industrialization process. The air pollution can be increased due to several different kinds of emissions: urban traffic, industrial activities, burning fuel, civil industry of construction/demolition, fires and natural phenomena. Many of these emissions move from long distances due to convections currents and finally tend to deposit mainly in the plants leaves and in the soil. Thus, the plants leaves works as a natural sampler by the emissions deposit in these ones. In this study Nerium oleander leaves were used to measure the environmental pollutions levels in different sampling urban regions in the city of Rio de Janeiro/RJ: Andarai, Benfica, Bonsucesso, Caju, Engenho de Dentro, Engenho Novo, Estacio, Grajau, Inhauma, Lins, Maracana, Maria da Graca, Meier, Praca da Bandeira, Riachuelo, Rio Comprido, Sao Cristovao, Tijuca, Vila Isabel and city Center. The control samples were collected in Campo Grande near of Parque Nacional da Pedra Branca/RJ (National Park of Pedra Branca/RJ). The leaves were collected from adult plants and after the collection the samples were cleaned and placed in the greenhouse for drying, then were mashed and pressed into tablets forms. The analyses were performed using the energy dispersion X-ray fluorescence (EDXRF), developed on the own laboratory and based in a SiPIN detector and a mini X ray tube. It was possible to detect 16 elements in the analyzed samples: K, Ca, Cr, Mn, Fe, Cu, Zn, Br, Rb, Sr, Ba and Pb. The results shows that, in the studied areas, the analysis of the Nerium oleander plant shows a low-cost option and with a substantial efficiency as an environmental pollution biomonitor. (author)

  3. Fundamental quantification procedure for total reflection X-ray fluorescence spectra analysis and elements determination

    International Nuclear Information System (INIS)

    Wegrzynek, D.; Holynska, B.

    1997-01-01

    A method for the determination of the concentrations of elements in particulate-like samples measured in total reflection geometry is proposed. In the proposed method the fundamental parameters are utilized for calculating the sensitivities of elements and an internal standard is used to account for the unknown mass per unit area of a sample and geometrical constant of the spectrometer. The modification of the primary excitation spectrum on its way to a sample has been taken into consideration. The concentrations of the elements to be determined are calculated simultaneously with the spectra deconvolution procedure. In the process of quantitative analysis the intensities of all X-ray peaks corresponding to K and L-series lines present in the analyzed spectrum are taken into account. (Author)

  4. A method for thickness determination of thin films of amalgamable metals by total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Bennun, L.; Greaves, E.D.; Barros, H.; Diaz-Valdes, J.

    2009-01-01

    A method for thickness determination of thin amalgamable metallic films by total-reflection X-ray fluorescence (TXRF) is presented. The peak's intensity in TXRF spectra are directly related to the surface density of the sample, i.e. to its thickness in a homogeneous film. Performing a traditional TXRF analysis on a thin film of an amalgamated metal, and determining the relative peak intensity of a specific metal line, the layer thickness can be precisely obtained. In the case of gold thickness determination, mercury and gold peaks overlap, hence we have developed a general data processing scheme to achieve the most precise results.

  5. Preconcentrate of thorium in solid phase and its direct determination by X-ray fluorescence in natural waters

    International Nuclear Information System (INIS)

    Carvalho, Marcelo S. de; Domingues, Maria de Lourdes F.; Mantovano, Jose Luiz; Cunha, Jose Waldemar S.D. da

    2000-01-01

    This paper describe a methodology to pre concentrate thorium from natural water samples by using solid phase extraction (SPE) before its direct determination by X-ray fluorescence. Polyurethane foam supporting 2- ethyl hexyl phosfonic acid was used as SPE. The extraction was maximum at 0.25 mol/L in hydrochloric acid, for 30 minutes of shaking time. At least 8 mg/L thorium could be determined what allowed us to apply this methodology successfully for determination of thorium in natural water reference samples. (author)

  6. Stratospheric particles: Synchrotron x-ray fluorescence determination of trace element contents

    International Nuclear Information System (INIS)

    Sutton, S.R.; Flynn, G.J.

    1987-01-01

    The first trace element analyses on stratospheric particles using synchrotron x-ray fluorescence (SXRF) are reported. Cr, Mn, Fe, Ni, Cu, Zn, Ga, Ge, Se and Br were detected. Concentrations for chondritic particle U2022G1 are within a factor of 1.7 of CI for all elements detected with the exception of Br which is 37 times CI. Chondritic particle W7029*A27 is also near CI for Cr, Mn, Fe, Ni, Cu, Zn and Ge but enriched in Ga, Se, and Br by factors of 5.8, 3.5 and 8.4, respectively. The third particle of the cosmic dust class also showed high Br enriched relative to CI by a factor of 28. Br was also detected at a high level in an aluminum-rich particle classified as probable artificial terrestrial contamination but exhibiting a chondritic Fe/Ni ratio. Br was not detected in a fifth particle also classified terrestrial and exhibiting a crustal Fe/Ni ratio. If the high Br has a pre-terrestrial origin, the ubiquity of the effect suggests that a large fraction of the chondritic interplanetary dust particles derive from a parent body (bodies) not sampled in the meteorite collection. 26 refs., 3 figs., 3 tabs

  7. Nondestructive determination of lead, cadmium, tin, antimony, and barium in ceramic glazes by radioisotope X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Anderson, D.L.; Cunningham, W.C.

    1996-01-01

    Quantitation capabilities of radioisotope X-ray fluorescence spectrometry (RXRFS) for determining lead, cadmium, tin, antimony, and barium in ceramic glazes were investigated. Twenty-one air-dried glazes and 85 fired glazes on test tiles were analyzed by using 109 Cd and 57 Co excitation sources. Accurate Pb determinations, with limits of detection (LODs) of about 0.3 mg/cm 2 for 5 min counting times, were achieved by using the 75 keV Κ α1 X-ray photopeak and a Pb foil calibration procedure. Cd, Sn, Sb, and Ba concentrations were determined with LODs from about 0.5 to 1.5 mg/cm 2 . For Pb and Ba, results obtained by using absorption corrections based only on element concentrations determined by RXRFS and an iterative approach led to analytical biases of ≤4% relative to results obtained by using corrections based on known total element compositions. Biases were more severe for Cd, Sn, and Sb because lower X-ray energies were involved and sensitivities varied as a function of matrix Pb content. Pb concentrations were above LODs (1.3-40 mg/cm 2 ) in 39 of 47 fired open-quotes food-safeclose quotes glazes and in 33 of the other 38 fired glazes (0.4-39 mg/cm 2 ). 15 refs., 9 figs., 9 tabs

  8. Determination of Fe in blood using portable X-ray fluorescence spectrometry: an alternative for sports medicine

    International Nuclear Information System (INIS)

    Zamboni, C.B.; Metairon, S.; Kovacs, L.; Macedo, D.V.; Rizzutto, M.A.

    2016-01-01

    An alternate methodology based on a portable X-ray fluorescence spectrometry (PXRFS) for determination of Fe in blood was evaluated. The iron concentrations was determined in whole blood of 18 male amateur athletes (runners) using this portable XRF spectrometer and compared with a control group (54 male donors at the same age but not involved with physical activities) obtained by XRF and NAA techniques. The Fe concentration in the blood of runners is an important factor in sports medicine contributing to the performance of endurance athletes as well as for proposing new protocols of clinical evaluation. (author)

  9. Background estimation in short-wave region during determination of total sample composition by x-ray fluorescence method

    International Nuclear Information System (INIS)

    Simakov, V.A.; Kordyukov, S.V.; Petrov, E.N.

    1988-01-01

    Method of background estimation in short-wave spectral region during determination of total sample composition by X-ray fluorescence method is described. 13 types of different rocks with considerable variations of base composition and Zr, Nb, Th, U content below 7x10 -3 % are investigated. The suggested method of background accounting provides for a less statistical error of the background estimation than direct isolated measurement and reliability of its determination in a short-wave region independent on the sample base. Possibilities of suggested method for artificial mixtures conforming by the content of main component to technological concemtrates - niobium, zirconium, tantalum are estimated

  10. An X-ray fluorescence method for the determination of Ba, Sr, Mo and Bi in thorium oxide

    International Nuclear Information System (INIS)

    Dixit, R.M.; Deshpande, S.S.

    1988-01-01

    A simple and rapid X-ray fluorescence method for the determination of Ba, Sr, Mo and Bi in thoria is described. Thorium oxide samples are dry-mixed thoroughly with pure boric acid in the ratio of 9:1. One gram of mixture is pressed as a double layer over a primary boric acid pellet. The precision and accuracy of the method have been determined. The power limits of detection are found to be around 20 ppm for most analytes. (author). 5 tables

  11. Determination of some main elements and traces by x-ray fluorescence analysis in silicate rocks: a comparative study of two analytical techniques

    International Nuclear Information System (INIS)

    Andrade, M.D. de.

    1977-01-01

    The determinations of silicon, magnesium, iron, potassium, calcium, titanium, manganese, barium, strontium, rubidium, zirconium and scandium in felsic and mafic rocks, by X ray fluorescence analysis are presented. (author)

  12. An X-ray fluorescence method for the determination of small quantities of elements collected on filters

    International Nuclear Information System (INIS)

    Bayon, A.; Diaz-Guerra, J.P.

    1981-01-01

    An X-ray fluorescence method for the determination of As, Ba, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, U, V and Zn collected on P.V.C. filters in concentration ranges from 0,6 to 1000 μg, depending on the element, is described. A sequential automatic spectrometer with a chromium tube is used for the Ba determination, while As, Hg, Pb, Se and U are better determined with a molybdenum one. For the rest of the elements a tungsten target is prefered. The interferences between AsKαsub(1,2) - PbLαsub(1,2) and CrKαsub(1,2) - Vkβsub(1,3) lines are corrected by applyng specific coefficients. The radial variation of the primary X-ray beam intensity on the irradiated surface has been specially studied with chromium, gold, molybdenum and tungsten tubes. For that purpose different X-ray wavelengths in the range 9,89 A to 0,56 A have been selected. The curves obtained show a rather high heterogeneity for the excitation source. This conclusion implies the need for an homogeneous distribution of elements on the filter. (author)

  13. An X-ray fluorescence method for the determination of small quantities el elements collected on filters

    International Nuclear Information System (INIS)

    Diaz-Guerra, J.P.; Bayon, A.

    1981-01-01

    An X-ray fluorescence method for the determination of As, Ba, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, U, V and Zn collected on P.V.C. filters in concentration ranges from 0,6 to 1000μg, depending on the element, is described. A sequential automatic spectrometer with a chromium tube is used for tho Ba determination, while As, Hg, Pb, Se and U are bottler determined with a molybdenum one. For the rest of the elements a tungsten target is preferred. The interferences between AsK α 1 ,2- PbL α 1 ,2 and CrK α 1 ,2-Vkβ 1 ,3 lines are corrected by applying specific coefficients. The radial variation of the primary X-ray beam intensity on the irradiated surface has been specially studied with chromium, gold, molybdenum and tungsten tubes. For that purpose different x-ray wavelengths in the range 9,89 A to 0,56 A have been selected. The curves obtained show a rather high heterogeneity for the excitation source. This conclusion implies the need for an homogeneous distribution of elements on the filter. (Author) 7 refs

  14. Determination of total iron in iron ore by x-ray fluorescence analysis using the Compton effect: comparison with others analytical techniques

    International Nuclear Information System (INIS)

    Castilho, M.V. de; Oliveira, R.C.

    1991-01-01

    Total iron in iron ores is determines by X-ray fluorescence analysis method using the compton effect. The Bragg angle is determined for compton no-coherent scattering related to K alpha of Rhodium. This measurement procedure can be used for best fitting of analytical results in X-ray fluorescence, when compared with others methods used for results corrections. (M.V.M.)

  15. Automated x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    O'Connell, A.M.

    1977-01-01

    A fully automated x-ray fluorescence analytical system is described. The hardware is based on a Philips PW1220 sequential x-ray spectrometer. Software for on-line analysis of a wide range of sample types has been developed for the Hewlett-Packard 9810A programmable calculator. Routines to test the system hardware are also described. (Author)

  16. Study of an X-ray fluorescence thin film method for the determination of uranium in low activity solutions

    International Nuclear Information System (INIS)

    Diaz-Guerra, J. P.

    1980-01-01

    The application of the X-ray fluorescence thin film technique to the uranium determination in nitric solutions for a concentration range from 1 g/l to 100 g/l and activity levels under 5 mCi/ml is studied. The most suited excitation and measurement conditions are also studied and the uranium matrix effect correction, which is performed through the double dilution, α U U interaction coefficient calculation and internal standard methods, is discussed. The specimen preparation is satisfactorily accomplished by using P.V.C. filters fixed on aluminium supports. (Author) 18 refs

  17. Determination of Cu, Cr, and As in preserved wood (Eucalyptus sp.) using x-ray fluorescent spectrometry techniques

    International Nuclear Information System (INIS)

    Sergio Matias Pereira Junior; Vera Akiko Maihara; Edson Goncalves Moreira; Vera Lucia Ribeiro Salvador; Ivone Mulako Sato

    2016-01-01

    Energy dispersive (EDXRF) and Portable (PXRF) X-ray fluorescence techniques are proposed for wood treatment control process and wood waste assortment. In this study, different retentions of chromated copper arsenate preservative were applied to Eucalyptus sp. sapwood samples. Cu, Cr and As were determined by XRF techniques in treated sapwood massive blocks and treated sapwood sawdust samples were analyzed by FAAS spectrometry (Flame Atomic Absorption) and INAA (Instrumental Neutron Activation Analysis). Cu, Cr and As mean values, obtained by FAASS and INAA, showed to be statically equal; however, XRF analysis showed considerable deviations, presenting the absorption and the enhancement effects in analytical lines. (author)

  18. Determination of iron and titanium in kaolins by the method of non-dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Bialy, N.; Kierzek, J.; Parus, J.

    1976-01-01

    The possibility of application of the radioactive source excited X-ray fluorescence analysis for titanium and iron determination in kaolins to the routine test of the refinement process has been studied. The iron content can be determined with a simple counting system using a single-channel pulse height analyser, argon filled proportional counter and 109 Cd source of 3 mCi for the excitation of K Fe rays. The samples were analyzed both as pellets and powders. The iron content ranged from 0.2-2.5% and titanium from 0.1-0.64%. The best values of precision and determination limit have been achieved for iron with 238 Pu and for titanium with 55 Fe. The precision and accuracy of the X-ray fluorescence method of iron and titanium determination in kaolins are comparable to those of the chemical method. For the simultaneous iron and titanium determination in the discussed region of concentration it is the most advantageous to use the plutonium source with the activity of several tens of mCi and Si(Li) detector with a moderate resolution (250-300 eV for 5.9 keV). The time of the analysis carried out by the described method is several times shorter than the chemical method. The apparatus used in this method is relatively simple, the sample preparation does not require any chemical treatment and the cost of labour of the sample preparation is minimal. (T.G.)

  19. Electroadsorption-assisted direct determination of trace arsenic without interference using transmission X-ray fluorescence spectroscopy.

    Science.gov (United States)

    Jiang, Tian-Jia; Guo, Zheng; Liu, Jin-Huai; Huang, Xing-Jiu

    2015-08-18

    An analytical technique based on electroadsorption and transmission X-ray fluorescence (XRF) for the quantitative determination of arsenic in aqueous solution with ppb-level limits of detection (LOD) is proposed. The approach uses electroadsorption to enhance the sensitivity and LOD of the arsenic XRF response. Amine-functionalized carbonaceous microspheres (NH2-CMSs) are found to be the ideal materials for both the quantitative adsorption of arsenic and XRF analysis due to the basic amine sites on the surface and their noninterference in the XRF spectrum. In electroadsorptive X-ray fluorescence (EA-XRF), arsenic is preconcentrated by a conventional three-electrode system with a positive electricity field around the adsorbents. Then, the quantification of arsenic on the adsorbents is achieved using XRF. The electroadsorption preconcentration can realize the fast transfer of arsenic from the solution to the adsorbents and improve the LOD of conventional XRF compared with directly determining arsenic solution by XRF alone. The sensitivity of 0.09 cnt ppb(-1) is obtained without the interferences from coexisted metal ions in the determination of arsenic, and the LOD is found to be 7 ppb, which is lower than the arsenic guideline value of 10 ppb given by the World Health Organization (WHO). These results demonstrated that XRF coupled with electroadsorption was able to determine trace arsenic in real water sample.

  20. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Science.gov (United States)

    Conti, C. C.; Anjos, M. J.; Salgado, C. M.

    2014-09-01

    X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br.

  1. X-ray Microprobe for Fluorescence and Diffraction Analysis

    International Nuclear Information System (INIS)

    Ice, G.E.

    2005-01-01

    X-ray diffraction (see unit 1.1) and x-ray excited fluorescence analysis are powerful techniques for the nondestructive measurement of crystal structure and chemical composition. X-ray fluorescence analysis is inherently nondestructive with orders of magnitude lower power deposited for the same detectable limit as with fluorescence excited by charged particle probes (Sparks, 1980). X-ray diffraction analysis is sensitive to crystal structure with orders-of-magnitude greater sensitivity to crystallographic strain than electron probes (Rebonato, et al. 1989). When a small-area x-ray microbeam is used as the probe, chemical composition (Z>14), crystal structure, crystalline texture, and crystalline strain distributions can be determined. These distributions can be studied both at the surface of the sample and deep within the sample (Fig. 1). Current state-of-the-art can achieve an ∼1 mm-D x-ray microprobe and an ∼0.1 mm-D x-ray microprobe has been demonstrated (Bilderback, et al., 1994). Despite their great chemical and crystallographic sensitivities, x-ray microprobe techniques have until recently been restricted by inefficient x-ray focusing optics and weak x-ray sources; x-ray microbeam analysis was largely superseded by electron techniques in the 50's. However, interest in x-ray microprobe techniques has now been revived (Howells, et al., 1983; Ice and Sparks, 1984; Chevallier, et al., 1997; Riekel 1992; Thompson, el al., 1992; and Making and Using... 1997) by the development of efficient x-ray focusing optics and ultra-high intensity synchrotron x-ray sources (Buras and Tazzari, 1984; Shenoy, et al., 1988). These advances have increased the achievable microbeam flux by more than 11 orders of magnitude (Fig. 2) (Ice, 1997); the flux in a tunable 1 mm-D beam on a 'so called' 3rd-generation synchrotron source such as the APS can exceed the flux in a fixed-energy mm2 beam on a conventional source. These advances make x-ray microfluorescence and x-ray

  2. An X-ray fluorescence method for the determination of metals thicknesses

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Leyt, D.V. de; Riveros, J.A.

    1987-01-01

    An absolute method for the determination of the thickness of a metal film deposited on a metallic substrate is described. The method is based on the measurement of fluorescent intensity ratios for two lines from the substrate element. Additionally, the proposed method can be employed to determine the density of the deposited material or the incident angle of primary radiation and take off angle, if the metal film thickness is known. (Author) [es

  3. Radioactivation and X-ray fluorescence methods of determination of some elements in atmospheric air and waters

    International Nuclear Information System (INIS)

    Kulmatov, R.A.; Kist, A.A.; Karimov, I.I.; Pulatov, D.D.; Kamil'dzhanov, A.Kh.

    1981-01-01

    Possibilities of instrumental radioactivation and X-ray fluorescence method of determining certain elements in aerosols and waters in the region of metallurgic production location and around it are considered. For conducting instrumental radioactivation analysis the samples have been irradiated on filter during 20h in the thermal neutron flux f=10 13 neutr/cm 2 xs of nuclear reactor-WWR-SM INP ASUzSSR. Measurement of induced activity has been conducted after 7 and 15-day cooling by means of Ge(Li) detectors. Averaged results of instrumental radioactivation and X-ray fluorescence analysis of element (Cu, Zn, Fe, Pb) composifion of some samples are presented. Content of such elements as copper, zinc, lead in the industrial region several times exceeds usual background content that is caused by industrial releases. Toxic effect, rate of aerosol release from atmosphere and radius of harmful effect of industrial enterprises on environment much depends on dispersion. A set of filter materials differing from one another by pore diameter have been used for conducting dispersion analysis of aerosals [ru

  4. Determinations of silicon and phosphorus in rice planted on a district of high incidence of amyotrophic lateral sclerosis by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Ishikawa, Teruumi; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1989-01-01

    Silicon and phosphorus contents in polished and unpolished rice planted on a district of high incidence of amyotrophic lateral sclerosis (ALS) have been determined by neutron activation and X-ray fluorescence methods, and compared with those from control areas. In the neutron activation analysis, β-ray spectra of 32 P produced by the 31 P(n, γ) 32 P reaction on polished and unpolished rice were measured with a low background β-ray spectrometer. In the X-ray fluorescence analysis, characteristic X-ray were analyzed with a wavelength dispersive X-ray fluorescence spectrometer. Silicon contents in polished and unpolished rice from the ALS area are 42 μg.g -1 and 370 μg.g -1 , respectively, and the corresponding phosphorus contents are 1210 μg.g -1 , and 3370 μg.g -1 , respectively. The data for ALS area are equal to those for the control area within atandard deviation. (author)

  5. Portable X-ray fluorescence analyzer of high sensitivity using X-ray tube excitation

    International Nuclear Information System (INIS)

    Vatai, E.; Ando, L.

    1982-01-01

    A review of the three main methods of X-ray fluorescence analysis and their problems is given. The attainable accuracy and effectiveness of each method are discussed. The main properties of portable X-ray analyzers required by the industry are described. The results and experiences of R and D activities in ATOMKI (Debrecen, Hungary) for developing portable X-ray analyzers are presented. The only way for increasing the accuracy and decreasing the measuring time is the application of X-ray tube excitation instead of radioactive sources. The new ATOMKI equipment presently under construction and patenting uses X-ray tube excitation; it will increase the accuracy of concentration determination by one order of magnitude. (D.Gy.)

  6. Energy dispersive x-ray fluorescence spectrometric determination of phosphorus, calcium, iron, zinc, and strontium in human bones

    International Nuclear Information System (INIS)

    Ohta, Akishige; Matsubayashi, Takashi; Itoman, Moritoshi

    1981-01-01

    Phosphorus, calcium, iron, zinc and strontium in a human bone extracted by surgery were determined by energy dispersive X-ray fluorescence spectrometry. The bone was decomposed with nitric acid, then diluted with water. A specific quantity of the solution was naturally dried on polyethylene film, and subjected to X-ray analysis. For determining the calibration curves in a mixture of phosphorus, calcium, iron, zinc and strontium, for the analysis of phosphorus and calcium, germanium was used as the secondary target and aluminum as the filter; and for the analysis of iron, zinc and strontium, molybdenum and molybdenum-aluminum were used, respectively. Consequently, the calibration curves were able to be obtained with high precision in the ranges from 5 to 500 μg of phosphorus, from 1 to 50 μg of calcium and from 0.1 to 1.0 μg of iron, zinc and strontium. In this way, in 1 mg of the human bone by wet weight, phosphorus, calcium, iron, zinc and strontium were able to be determined. (J.P.N.)

  7. Radionuclide X-ray fluorescence determination of Mn, Fe, Cu, Zn and Pb in wastewaters and sludges from wastewater treatment plants in Bratislava (SR)

    International Nuclear Information System (INIS)

    Harangozo, M.; Toelgyessy, J.

    1997-01-01

    Radiometric X-ray fluorescence analysis was used for the determination of Mn, Fe, Cu, Zn and Pb in wastewater and sludges from three wastewater treatment plants in Bratislava (SR). Metals were determined in wastewaters after preconcentration by 8-hydroxyquinoline and in sludges by drying and pressing to pellets. 238 Pu and 109 Cd was used for excitation of fluorescence radiation. (author)

  8. X-ray fluorescence analysis of Fe - Ni - Mo systems

    International Nuclear Information System (INIS)

    Belyaev, E.E.; Ershov, A.V.; Mashin, A.I.; Mashin, N.I.; Rudnevskij, N.K.

    1998-01-01

    Procedures for the X-ray fluorescence determination of the composition and thickness of Fe - Ni - Mo thin films and the concentration of elements in thick films of the Fe - Ni - Mo alloy are developed [ru

  9. Determination of arsenic in geological materials by x-ray fluorescence spectrometry after solvent extraction and deposition on a filter

    Science.gov (United States)

    Hubert, A.E.

    1983-01-01

    Rock, soil, or sediment samples are decomposed with a mixture of nitric and sulphuric adds. After reduction from arsenic(V) with ammonium thiosulphate, arsenic(III) is extracted as the chlorocomplex into benzene from a sulphuric-hydrochloric acid medium. The benzene solution is transferred onto a filter-paper disc impregnated with a solution of sodium bicarbonate and potassium sodium tartrate, and the benzene allowed to evaporate. The arsenic present is determined by X-ray fluorescence. In a 0.5-g sample, 1-1000 ppm of arsenic can be determined. The close proximity of the lead L?? peak (2?? 48.73??), to the arsenic K?? peak (2?? 48.83??) does not cause any interference, because lead is not extracted under the experimental conditions. Arsenic values obtained are in agreement with those reported for various reference samples. ?? 1983.

  10. Major constituent quantitative determination in uranium alloys by coupled plasma atomic emission spectrometry and X ray fluorescence wavelength dispersive spectrometry

    International Nuclear Information System (INIS)

    Oliveira, Luis Claudio de; Silva, Adriana Mascarenhas Martins da; Gomide, Ricardo Goncalves; Silva, Ieda de Souza

    2013-01-01

    A wavelength-dispersive X-ray fluorescence (WD-XRF) spectrometric method for determination of major constituents elements (Zr, Nb, Mo) in Uranium/Zirconium/Niobium and Uranium/Molybdenum alloy samples were developed. The methods use samples taken in the form of chips that were dissolved in hot nitric acid and precipitate particles melted with lithium tetraborate and dissolved in hot nitric acid and finally analyzed as a solution. Studies on the determination by inductively coupled plasma optic emission spectrometry (ICP OES) using matched matrix in calibration curve were developed. The same samples solution were analyzed in both methods. The limits of detection (LOD), linearity of the calibrations curves, recovery study, accuracy and precision of the both techniques were carried out. The results were compared. (author)

  11. Determination of copper, iron and zinc in spirituous beverages by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Capote, T.; Marcó, L. M.; Alvarado, J.; Greaves, E. D.

    1999-10-01

    The concentration of copper in traditional homemade alcoholic distillates produced in Venezuela (Cocuy de Penca) were determined by total reflection X-ray fluorescence (TXRF) using vanadium as internal standard. The results were compared to those obtained by flame atomic absorption spectrometry (FAAS). Three preparative methods of addition of vanadium were compared: classical internal standard addition, 'layer on layer' internal standard addition and in situ addition of internal standard. The TXRF procedures were accurate and the precision was comparable to that obtained by the FAAS technique. Copper levels were above the maximum allowed limits for similar beverages. Zinc and iron in commercial and homemade distilled beverages were also analyzed by TXRF with in situ addition of internal standard demonstrating the usefulness of this technique for trace metal determination in distillates.

  12. Determination of rare earth oxides in Li{sub 2}CO{sub 3} by x-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mengfu, Wei; Xinmian, Xu [Sichuan Inst. of Material and Technology (China)

    1994-07-01

    The mechanism of light elements incoherent scatter has been studied. By combining the incoherent scatter intensity with character line intensity to calculate the appearance concentration, the Lucas-Tooth and Pyne intensity correction model is corrected. By using this model and least-square method of regression of linear equations, the x-ray fluorescence analysis method is used for determining Sc{sub 2}O{sub 3}, Y{sub 2}O{sub 3}, La{sub 2}O{sub 3}, Tm{sub 2}O{sub 3} and Lu{sub 2}O{sub 3} in Li{sub 2}CO{sub 3} which are standard samples in the laboratory. The precision of the method is better than 4.0%, and the best is up to 1.4%. Advantages of the method are accurate, easy to control, fast and various elements can be simultaneously determined.

  13. Preparation of specimens for analysis by: X-ray diffraction and X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Banos L, L.

    2004-01-01

    Specimen preparation is one of the most important requirements in the analysis of samples by X-ray Diffraction and X-ray Fluorescence. This statement is especially true for samples containing different types of materials. There are many forms of specimen suitable for X-ray analysis and the type of the sample as received will generally determine the method of pretreatment. It is convenient to refer to the material received for analysis as the sample, and that, which is actually analyzed as the specimen. The powder Diffraction method assumes that the particles in the specimen are ideally random orientation and that there are enough crystallites in the specimen to achieve a representative intensity distribution for these crystallites. X ray Fluorescence is essentially a comparative method of analysis, it is vital that all standards and unknowns be presented to the spectrometer in a reproducible and identical manner. (Author) 3 refs., 6 figs

  14. Determination of fluorine concentrations using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry to analyze fluoride precipitates.

    Science.gov (United States)

    Lee, H. A.; Lee, J.; Kwon, E.; Kim, D.; Yoon, H. O.

    2015-12-01

    In recent times, fluorine has been receiving increasing attention due to the possibility for chemical (HF) leakage accidents and its high toxicity to human and environment. In this respect, a novel approach for the determination of fluorine concentrations in water samples using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry was investigated in this study. The main disadvantage of WDXRF technique for fluorine analysis is low analytical sensitivity for light elements with atomic number (Z) less than 15. To overcome this problem, we employed the precipitation reaction which fluoride is reacted with cation such as Al3+ and/or Ca2+ prior to WDXRF analysis because of their high analytical sensitivity. The cation was added in fluoride solutions to form precipitate (AlF3 and/or CaF2) and then the solution was filtered through Whatman filter. After drying at 60 °C for 5 min, the filter was coated with X-ray film and directly analyzed using WDXRF spectrometry. Consequently, we analyzed the cation on filter and subsequently fluorine concentration was calculated inversely based on chemical form of precipitate. This method can improve the analytical sensitivity of WDXRF technique for fluorine analysis and be applicable to various elements that can make precipitate.

  15. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Energy Technology Data Exchange (ETDEWEB)

    Conti, C.C., E-mail: ccconti@ird.gov.br [Institute for Radioprotection and Dosimetry – IRD/CNEN, Rio de Janeiro (Brazil); Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Anjos, M.J. [Physics Institute, State University of Rio de Janeiro – UERJ, Rio de Janeiro (Brazil); Salgado, C.M. [Nuclear Engineering Institute – IEN/CNEN, Rio de Janeiro (Brazil)

    2014-09-15

    Highlights: •This work describes a procedure for sample self-absorption correction. •The use of Monte Carlo simulation to calculate the mass attenuation coefficients curve was effective. •No need for transmission measurement, saving time, financial resources and effort. •This article provides de curves for the 90° scattering angle. •Calculation on-line at (www.macx.net.br). -- Abstract: X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at (www.macx.net.br)

  16. Determination of mercury in seawater by total reflection x-ray fluorescence spectrometry after an electrochemical preconcentration method

    International Nuclear Information System (INIS)

    Ritschel, A.; Chinea Cano, E.; Wobrauschek, P.; Kuntner, C.; Durakbasa, M.N.

    2000-01-01

    A new combined method of electrodeposition of trace elements on metallic plates with subsequent total-reflection x-ray fluorescence spectrometry (TXRF) is proposed for the determination of trace metals in natural waters. The elements of interest are electroplated on highly polished niobium discs which are used as sample carriers for the TXRF measurement. The electrochemical preconcentration is performed in a flow cell under a controlled working electrode potential. The preconcentration step involves only very little manipulation which minimizes the risk of contamination of the sample. The method was investigated by analyzing inorganic mercury in sea water. A detection limit of 7 ngl -1 could be achieved for mercury in a 40 ml sea water sample. (author)

  17. Determination of sulfur and chlorine in fodder by X-ray fluorescence spectral analysis and comparison with other analytical methods

    Science.gov (United States)

    Nečemer, Marijan; Kump, Peter; Rajčevič, Marija; Jačimović, Radojko; Budič, Bojan; Ponikvar, Maja

    2003-07-01

    Sulfur and chlorine are essential elements in the metabolic processes of ruminants, and correct planning strategy of ruminant nutrition should provide a sufficient content of S and Cl in the animal's body. S and Cl can be found in various types of animal fodder in the form of organic compounds and minerals. In this work, the Cl and S content in forage was determined by X-ray fluorescence spectrometry (XRF), and its performance was then compared in parallel analyses by instrumental neutron activation analysis (INAA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and potentiometric methods. The results were compared and critically evaluated in order to assess the performance and capability of the XRF technique in analysis of animal fodder.

  18. Determination of sulfur and chlorine in fodder by X-ray fluorescence spectral analysis and comparison with other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Necemer, Marijan; Kump, Peter; Rajcevic, Marija; Jacimovic, Radojko; Budic, Bojan; Ponikvar, Maja

    2003-07-18

    Sulfur and chlorine are essential elements in the metabolic processes of ruminants, and correct planning strategy of ruminant nutrition should provide a sufficient content of S and Cl in the animal's body. S and Cl can be found in various types of animal fodder in the form of organic compounds and minerals. In this work, the Cl and S content in forage was determined by X-ray fluorescence spectrometry (XRF), and its performance was then compared in parallel analyses by instrumental neutron activation analysis (INAA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and potentiometric methods. The results were compared and critically evaluated in order to assess the performance and capability of the XRF technique in analysis of animal fodder.

  19. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    Energy Technology Data Exchange (ETDEWEB)

    Pessanha, Sofia [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Carvalho, Maria Luisa, E-mail: luisa@cii.fc.ul.p [Centro Fisica Atomica, Departamento de Fisica, Faculdade de Ciencias, Universidade de Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa (Portugal); Becker, Maria; Bohlen, Alex von [Institute for analytical Sciences, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund (Germany)

    2010-06-15

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  20. Quantitative determination on heavy metals in different stages of wine production by Total Reflection X-ray Fluorescence and Energy Dispersive X-ray Fluorescence: Comparison on two vineyards

    International Nuclear Information System (INIS)

    Pessanha, Sofia; Carvalho, Maria Luisa; Becker, Maria; Bohlen, Alex von

    2010-01-01

    The purpose of this study is to determine the elemental content, namely heavy metals, of samples of vine-leaves, grapes must and wine. In order to assess the influence of the vineyard age on the elemental content throughout the several stages of wine production, elemental determinations of trace elements were made on products obtained from two vineyards aged 6 and 14 years from Douro region. The elemental content of vine-leaves and grapes was determined by Energy Dispersive X-Ray Fluorescence (EDXRF), while analysis of the must and wine was performed by Total Reflection X-ray Fluorescence (TXRF). Almost all elements present in wine and must samples did not exceed the recommended values found in literature for wine. Bromine was present in the 6 years old wine in a concentration 1 order of magnitude greater than what is usually detected. The Cu content in vine-leaves from the older vineyard was found to be extremely high probably due to excessive use of Cu-based fungicides to control vine downy mildew. Higher Cu content was also detected in grapes although not so pronounced. Concerning the wine a slightly higher level was detected on the older vineyard, even so not exceeding the recommended value.

  1. Trace elements determination in Syrian honey using x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Khuder, A.; Ahmad, M.; Saour, G.

    2009-05-01

    Major and trace elements of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr in 27 Syrian honey samples, which collected from different areas in the country, in addition to 3 imported honey samples, were determined by dry ashing method for XRF analysis. The samples were diluted and homogenized with a binder made from cellulose powder. The analyzed elements were divided into three groups, relating to the secondary targets used for X-ray excitation. The internal standard method for XRF analysis with a Mo secondary target was used for the determination of the first group of elements: Sr, Rb, Se, As, Zn, Cu, Ni, and Fe. While, the external standard method for XRF analysis with Cu and Ti secondary targets was used for the determination of the second: Mn, Cr, Ti, Ca, K, and third: Cl, and S group of elements, respectively. The results were accurate with a relative standard error less than 4.2 %. The problem of element loss was overcome by the complete drying of honey samples before their ashing. The moisture content was obtained using mass loss and refractive index methods. As a result, the lower limits of detection (LLD) obtained by Mo-XRF was in the range from 0.011 μg Sr/g to 0.064 μg Fe/g, resulting for samples containing 0.1 % ash and collecting live time 1000 s; while, LLD obtained by Cu-XRF was in the range 0.014 μg Mn/g to 0.057 μg K/g. LLD for S and Cl using Ti secondary target was with values of 0.503 μg/g and 1.96 μg/g, respectively. The enhancement factor obtained by drying method for XRF was in the range from 147 to 1667. Normal concentration of elements in Syrian honey was obtained. The concentration of elements was comparable to those obtained by other workers for honeys in different countries. Elements of K, Ca, and Cl were predominantly distributed in all Syrian honey samples. Elements of Sr, Zn, Cu, Fe, Ti, and S were well distributed in all honey samples. While, the concentrations of Rb, Ni, Mn, Cr elements in some honey samples were below the

  2. The determination, by x-ray-fluorescence spectrometry, of gold, silver, and base metals on activated carbon

    International Nuclear Information System (INIS)

    Wall, G.; Jacobs, J.J.; Dixon, K.

    1980-01-01

    The method proposed involves ashing of the sample at a low temperature in a muffle furnace, mixing of the ash with alumina and boric acid in a Siebtechnik mill, and briquetting of the mixture. The elements are measured in the briquette by the use of x-ray fluorescence spectrometry. The detailed laboratory method is given in an appendix [af

  3. [Rapid determination of major and trace elements in the salt lake clay minerals by X-ray fluorescence spectrometry].

    Science.gov (United States)

    Wang, Xiao-Huan; Meng, Qing-Fen; Dong, Ya-Ping; Chen, Mei-Da; Li, Wu

    2010-03-01

    A rapid multi-element analysis method for clay mineral samples was described. This method utilized a polarized wave-length dispersive X-ray fluorescence spectrometer--Axios PW4400, which had a maximum tube power of 4 000 watts. The method was developed for the determination of As, Mn, Co, Cu, Cr, Dy, Ga, Mo, P, Pb, Rb, S, Sr, Ni, ,Cs, Ta, Th, Ti, U, V, Y, Zn, Zr, MgO, K2O, Na2O, CaO, Fe2O3, Al2O3, SiO2 and so on. Thirty elements in clay mineral species were measured by X-ray fluorescence spectrometry with pressed powder pellets. Spectral interferences, in particular the indirect interferences of each element, were studied. A method to distinguish the interference between each other periodic elements in element periodic table was put forward. The measuring conditions and existence were mainly investigated, and the selected background position as well as corrected spectral overlap for the trace elements were also discussed. It was found that the indirect spectral overlap line was the same important as direct spectral overlap line. Due to inducing the effect of indirect spectral overlap, some elements jlike Bi, Sn, W which do not need analysis were also added to the elements channel. The relative standard deviation (RSD) was in the range of 0.01% to 5.45% except three elements Mo, Cs and Ta. The detection limits, precisions and accuracies for most elements using this method can meet the requirements of sample analysis in clay mineral species.

  4. Advanced in X-ray fluorescence holography

    CERN Document Server

    Hayashi, K

    2002-01-01

    X-ray fluorescence holography (XFH) can resolve 'phase problem' in crystal diffraction and therefore it provides 3D atomic images around specific elements. Since first demonstration of the XFH in 1996, view of atoms has been improved rapidly with the refinement of the hologram data collection method. The present performance of the XFH makes it possible to apply to impurity, thin film and quasicrystal, and opens a way to practical tool for determination of local structure. In this paper, theory including solutions for twin image problem, advanced experimental systems and application to Si sub 0 sub . sub 9 sub 9 sub 9 Ge sub 0 sub . sub 0 sub 0 sub 1 are discussed. (author)

  5. L X-ray fluorescence cross sections experimentally determined for elements with 45

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, Edgardo V., E-mail: bonzie@famaf.unc.edu.ar [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Badiger, Nagappa M. [Departments of Physics, Karnatak University, Dharwad 580 003, Karnataka (India); Grad, Gabriela B. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria-5010, Cordoba (Argentina); Barrea, Raul A. [The Biophysics Collaborative Access Team (BioCAT), Dept of Biological Chemical, and Physical Sciences, Illinois Institute of Technology, Chicago, IL 60616 (United States); Figueroa, Rodolo G. [Departamento de Cs. Fisicas, Universidad de La Frontera, Temuco (Chile)

    2012-04-15

    Experimental determination of L fluorescence cross-sections for elements with 45determined at 9 keV using Synchrotron radiation. This work is part of an investigation we did at low energies in the same group of elements. The individual L X-ray photons, Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} produced in the target were measured using a Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross sections obtained in this work were compared with data calculated using coefficients from , , and Scofield and Puri et al. (1993, 1995) - Highlights: Black-Right-Pointing-Pointer Experimental data of L fluorescence cross-sections with 45determined at 9 keV by Synchrotron radiation. Black-Right-Pointing-Pointer The cross sections Ll, L{alpha}, L{beta}{sub I}, L{beta}{sub II}, L{gamma}{sub {Iota}} and L{gamma}{sub {Iota}{Iota}} obtained, were compared with calculated data. Black-Right-Pointing-Pointer The Hypermet function was used to fit the data, because it considers a tail on the left side of the peak. Black-Right-Pointing-Pointer The tail is relevant when a small peak has another one on the right side with a big area.

  6. Synchrotron x-ray fluorescence and extended x-ray absorption fine structure analysis

    International Nuclear Information System (INIS)

    Chen, J.R.; Gordon, B.M.; Hanson, A.L.; Jones, K.W.; Kraner, H.W.; Chao, E.C.T.; Minkin, J.A.

    1984-01-01

    The advent of dedicated synchrotron radiation sources has led to a significant increase in activity in many areas of science dealing with the interaction of x-rays with matter. Synchrotron radiation provides intense, linearly polarized, naturally collimated, continuously tunable photon beams, which are used to determine not only the elemental composition of a complex, polyatomic, dilute material but also the chemical form of the elements with improved accuracy. Examples of the application of synchrotron radiation include experiments in synchrotron x-ray fluorescence (SXRF) analysis and extended x-ray absorption fine structure (EXAFS) analysis. New synchrotron radiation x-ray microprobes for elemental analysis in the parts per billion range are under construction at several laboratories. 76 references, 24 figures

  7. Escape probabilities for fluorescent x-rays

    International Nuclear Information System (INIS)

    Dance, D.R.; Day, G.J.

    1985-01-01

    Computation of the energy absorption efficiency of an x-ray photon detector involves consideration of the histories of the secondary particles produced in any initial or secondary interaction which may occur within the detector. In particular, the K or higher shell fluorescent x-rays which may be emitted following a photoelectric interaction can carry away a large fraction of the energy of the incident photon, especially if this energy is just above an absorption edge. The effects of such photons cannot be ignored and a correction term, depending upon the probability that the fluorescent x-rays will escape from the detector, must be applied to the energy absorption efficiency. For detectors such as x-ray intensifying screens, it has been usual to calculate this probability by numerical integration. In this note analytic expressions are derived for the escape probability of fluorescent photons from planar detectors in terms of exponential integral functions. Rational approximations for these functions are readily available and these analytic expressions therefore facilitate the computation of photon absorption efficiencies. A table is presented which should obviate the need for calculating the escape probability for most cases of interest. (author)

  8. Development of confocal micro X-ray fluorescence instrument using two X-ray beams

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Nakano, Kazuhiko; Ding Xunliang

    2007-01-01

    A new confocal micro X-ray fluorescence instrument was developed. This instrument has two independent micro X-ray tubes with Mo targets. A full polycapillary X-ray lens was attached to each X-ray tube. Another half polycapillary lens was attached to a silicon drift X-ray detector (SDD). The focal spots of the three lenses were adjusted to a common position. The effects of the excitation of two X-ray beams were investigated. The instrument enabled highly sensitive three-dimensional X-ray fluorescence analysis. We confirmed that the X-ray fluorescence intensity from the sample increased by applying the two independent X-ray tubes in confocal configuration. Elemental depth profiling of black wheat was demonstrated with the result that each element in the surface coat of a wheat grain showed unique distribution

  9. Millianalyser by x-ray fluorescence

    International Nuclear Information System (INIS)

    Kawamoto, A.; Hirao, O.; Kashiwakura, J.; Gohshi, Y.

    1976-01-01

    Research on the possibility of mm-size nondestructive analysis was carried out by the fluorescent x-ray method. With 0.2 mm pin-hole slit, source x-rays from a Cu target diffraction tube were collimated to a spot smaller than 1 mm phi at a slide stage placed about 5 cm distant from the pin-hole slit. Resultant x-rays from a sample placed on the slide stage, which is excited by the collimated x-ray, were detected with a head-on-type 6 mm SSD, placed so that its 12.5 micron Be window was about 5 cm beneath the stage. X-ray intensities sufficient for analysis (500 to 5000 CPS) could be obtained for various metallic samples with up to 40 kV-10 mA excitation. This instrument proved to be useful for mm-size qualitative analysis in measurements of tiny samples. Furthermore, the possibility of distribution analysis is expected based on the result of an investigation on c.a. 0.1 percent Cr in LiNbO 3 , where the ratios of Cr-Kα intensity to scattered Cu-Kα intensity varied between 0.094 and 0.19, with deviations of less than 7.5 percent at five successive points located at 2 mm intervals along the direction of growth

  10. X-ray fluorescence determination of composition of the high temperature superconductors by the fundamental parameter method

    International Nuclear Information System (INIS)

    Mao Zhenwei; Shi Lei; Chen Shuyu; Zhou Guien

    2001-01-01

    Y, Pr, Ba and Cu compositions of the series of the Y 1-x Pr x Ba 2 Cu 3 O y samples have been determined by using X-ray fluorescence (XRF) fundamental parameter method in a non-destruction state. The composition is given by an atomic fraction. The determined compositions of the samples show a difference from their nominal compositions. One of the reasons why the exact shape of T c vs x varies is different from group to group, as reported, is the difference of the real and the nominal compositions. The relation of T c vs x is not a simple quadric curve. The results agree well with those obtained by the inductively coupled plasma atomic emission spectrometer (ICP-AES), which indicates that the method is appropriate for the determination of the compositions of the high temperature superconductors. In addition, the influence of oxygen on analytical elements is discussed. The fraction of the matrix total mass absorption, which is associated with oxygen for each analytical line, is less than 3.41%

  11. Synchrotron x-ray microbeam characteristics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Iida, Atsuo; Noma, Takashi

    1995-01-01

    X-ray fluorescence analysis using a synchrotron x-ray microprobe has become an indispensable technique for non-destructive micro-analysis. One of the most important parameters that characterize the x-ray microbeam system for x-ray fluorescence analysis is the beam size. For practical analysis, however, the photon flux, the energy resolution and the available energy range are also crucial. Three types of x-ray microbeam systems, including monochromatic and continuum excitation systems, were compared with reference to the sensitivity, the minimum detection limit and the applicability to various types of x-ray spectroscopic analysis. 16 refs., 5 figs

  12. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  13. Determination of Mn, Fe, Ni, Cu, Zn and Pb contents in samples in samples of apple trees by radionuclide X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Bumbalova, A.; Havranek, E.; Harangozo, M.

    1982-01-01

    The applicability of the radionuclide X-ray fluorescence analysis (RXFA) for qualitative and quantitative evaluation of environmental plant samples is discussed and examples of determination of Mn, Fe, Ni, Cu, Zn, Pb in samples of apple trees are given. The instrumentation, the standard and sample preparation are also presented. (author)

  14. The determination of major and some minor constituents in lead zirconate-titanate compositions by x-ray fluorescence and atomic absorption spectrometry

    NARCIS (Netherlands)

    van Willigen, J.H.H.G.; Kruidhof, H.; Dahmen, E.A.M.F.

    1972-01-01

    An accurate X-ray fluorescence spectrometric method is described for the determination of lead, zirconium and titanium in lead zirconate-titanate ceramics. Careful matching of samples and standards by a borax fusion method resulted in a relative standard deviation of about 0.2% for the major

  15. Total reflection X-ray fluorescence as a convenient tool for determination of trace elements in microscale gasoline and diesel

    Science.gov (United States)

    Zhang, Airui; Jin, Axiang; Wang, Hai; Wang, Xiaokang; Zha, Pengfei; Wang, Meiling; Song, Xiaoping; Gao, Sitian

    2018-03-01

    Quantitative determination of trace elements like S, Fe, Cu, Mn and Pb in gasoline and S in diesel is of great importance due to the growing concerns over air pollution, human health and engine failure caused by utilization of gasoline and diesel with these harmful elements. A method of total reflection X-ray fluorescence (TXRF) was developed to measure these harmful trace elements in gasoline and diesel. A variety of factors to affect measurement results, including TXRF parameters, microwave-assisted digestion conditions and internal standard element and its addition, were examined to optimize these experimental procedures. The hydrophobic treatment of the surface of quartz reflectors to support the analyte with neutral silicone solutions could prepare thin films of gasoline and diesel digestion solutions for subsequent TXRF analysis. The proposed method shows good potential and reliability to determine the content of harmful trace elements in gasoline and diesel with high sensitivity and accuracy without drawing different standard calibration curves, and can be easily employed to screen gasoline and diesel in routine quality control and assurance.

  16. The Determination of Composite Elements in Zircaloy-2 by X-Ray Fluorescence and Emission Spectrometry Method

    International Nuclear Information System (INIS)

    Dian Anggraini; Rosika Kriswarini; Yusuf N

    2007-01-01

    Analysis of composing elements in zircaloy-2 has been done by Emission Spectrometry method and X-Ray Fluorescence (XRF). The aim of the analysis is to verify conformity between composing elements in zircaloy-2 and the material certificate. Spectrometry Emission method has higher sensitivity in element determination of a material than that of XRF method, so can be estimated that emission spectrometry method has higher accuracy than that of XRF method. The result of qualitative analysis by Emission Spectrometry indicate that the composing elements in zircaloy-2 were Sn, Cr and Ni. However, the qualitative analysis result by XRF method indicated that the composing elements in zircaloy 2 were Sn, Cr, Ni and Fe. Fe element can not be analysed by Emission Spectrometry method because Emission Spectrometer did not equipped with Fe detector. The quantitative analysis result of the composing elements in the material with both methods showed that Sn, Cr and Ni concentration of zircaloy 2 existed in concentration ranges of the material certificate. Result of statistical test (F and t-test) of analysis result of both methods can be used for analyzing composing elements in zircaloy 2. Emission Spectrometry method was more sensitive and accurate for determining Cr and Ni element in zircaloy 2 than that of emission Spectrometry method but both methods had same accuracy. The precision of measurement of Sn, Cr and Ni element using XRF method was better than that of Emission spectrometry method. (author)

  17. DETERMINATION OF MINERAL COMPOSITION OF ORGANIC AND CONVENTIONAL BEVERAGES BY DISPERSIVE ENERGY X-RAY FLUORESCENCE SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    L. CONSOLI

    2012-11-01

    Full Text Available Fruits are natural sources of minerals whose ingestion is recommended in a balanced diet. The increasing consumption of fruit-based beverages demands the development of rapid methods to evaluate their quality parameters. X-ray fluorescence spectrometry is an analytical-nuclear technique that is gaining space in the environmental and geological fields, and has been explored modestly in the food field. The main objective of this work was to develop a methodology to determine the mineral content of fruit-based beverages by applying this technique. Beverages manufactured from organic and conventional fruit varieties were evaluated, aiming to compare their nutritional value. The research was divided into three steps: in the first step, a direct measurement of the samples was made, that is, without prior preparation; in the second, standard curves were prepared with the elements of calcium and potassium, based on the category of ‘fine samples’. Lastly, these curves were used to determine concentrations of calcium and potassium in the samples of juices and pulps prepared as ‘fine samples’. The fine sample measurements showed results more exact compared to that obtained from the direct measurements. From the data evaluated, it was not possible to attribute better nutritional quality to either the organic or conventional samples.

  18. X-ray fluorescence determination of Sn, Sb, Pb in lead-based bearing alloys using a solution technique

    Science.gov (United States)

    Tian, Lunfu; Wang, Lili; Gao, Wei; Weng, Xiaodong; Liu, Jianhui; Zou, Deshuang; Dai, Yichun; Huang, Shuke

    2018-03-01

    For the quantitative analysis of the principal elements in lead-antimony-tin alloys, directly X-ray fluorescence (XRF) method using solid metal disks introduces considerable errors due to the microstructure inhomogeneity. To solve this problem, an aqueous solution XRF method is proposed for determining major amounts of Sb, Sn, Pb in lead-based bearing alloys. The alloy samples were dissolved by a mixture of nitric acid and tartaric acid to eliminated the effects of microstructure of these alloys on the XRF analysis. Rh Compton scattering was used as internal standard for Sb and Sn, and Bi was added as internal standard for Pb, to correct for matrix effects, instrumental and operational variations. High-purity lead, antimony and tin were used to prepare synthetic standards. Using these standards, calibration curves were constructed for the three elements after optimizing the spectrometer parameters. The method has been successfully applied to the analysis of lead-based bearing alloys and is more rapid than classical titration methods normally used. The determination results are consistent with certified values or those obtained by titrations.

  19. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Haydn [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of); Marco Parra, Lue-Meru, E-mail: luemerumarco@yahoo.e [Universidad Centroccidental Lisandro Alvarado, Dpto. Quimica y Suelos, Decanato de Agronomia, Tarabana, Cabudare, Edo.Lara (Venezuela, Bolivarian Republic of); Bennun, Leonardo [Universidad de Concepcion, Concepcion (Chile); Greaves, Eduardo D. [Laboratorio de Fisica Nuclear, Dpto. De Fisica, Universidad Simon Bolivar, Sartenejas, Baruta (Venezuela, Bolivarian Republic of)

    2010-06-15

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-K{alpha} and Co-K{alpha} lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 {mu}gL{sup -1}. The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  20. Determination of arsenic in water samples by Total Reflection X-Ray Fluorescence using pre-concentration with alumina

    International Nuclear Information System (INIS)

    Barros, Haydn; Marco Parra, Lue-Meru; Bennun, Leonardo; Greaves, Eduardo D.

    2010-01-01

    The determination of arsenic in water samples requires techniques of high sensitivity. Total Reflection X-Ray Fluorescence (TXRF) allows the determination but a prior separation and pre-concentration procedure is necessary. Alumina is a suitable substrate for the selective separation of the analytes. A method for separation and pre-concentration in alumina, followed by direct analysis of the alumina is evaluated. Quantification was performed using the Al-Kα and Co-Kα lines as internal standard in samples prepared on an alumina matrix, and compared to a calibration with aqueous standards. Artificial water samples of As (III) and As (V) were analyzed after the treatment. Fifty milliliters of the sample at ppb concentration levels were mixed with 10 mg of alumina. The pH, time and temperature were controlled. The alumina was separated from the slurry by centrifugation, washed with de-ionized water and analyzed directly on the sample holder. A pre-concentration factor of 100 was found, with detection limit of 0.7 μgL -1 . The percentage of recovery was 98% for As (III) and 95% for As (V) demonstrating the suitability of the procedure.

  1. The determination of iron, chromium, titanium, and tungsten by x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Austen, C.E.

    1977-01-01

    An accurate and precise method is described for the determination of iron and chromium in chromite, iron and titanium in ilmenite, and tungsten in tungsten ores. Samples are prepared for analysis by fusion with sodium peroxide or sodium tetraborate and leaching of the melt in a solution of tartaric or hydrochloric acid. Matrix correction and calibration are achieved by means of the single-standard calibration method with reference solutions prepared from compounds of the elements determined

  2. Thickness determination of thin solid films by angle-resolved X-ray fluorescence spectrometry using monochromatized synchrotron radiation

    Science.gov (United States)

    Schmitt, W.; Drotbohm, P.; Rothe, J.; Hormes, J.; Ottermann, C. R.; Bange, K.

    1995-05-01

    Thickness measurements by the method of angle-resolved, self-ratio X-ray fluorescence spectrometry (AR/SR/XFS) have been carried out on thin solid films using monochromatized synchrotron radiation at the Bonn storage ring ELSA. Synchrotron radiation was monochromatized by means of a double-crystal monochromator and fluorescence radiation was detected by a Si(Li) semiconductor detector. The results for sample systems consisting of Au on Si, Cr on SiO2 and TiO2 on alkali-free glass are very satisfactory and agree well with results obtained by other methods.

  3. Instrumental parameters' determination in a fluorescences X-ray Philips PW 1400 equipment

    International Nuclear Information System (INIS)

    Martinez, J.M.; Fasio, I.; Baronio, N.; Viola, M.

    1987-01-01

    The instrumental parameters of a Philips PW 1400 equipment wavelengths dispersive are determined; fundamentally, those related to the equipment's accuracy (stability at a very short, short and long term drift) as well as to those related to the detection system (dead time, detector's cleaning and detection limit). (S.M.) [es

  4. Trace metal determinations by total-reflection x-ray fluorescence analysis in the open Atlantic Ocean

    International Nuclear Information System (INIS)

    Schmidt, D.; Gerwinski, W.; Radke, I.

    1993-01-01

    The Intergovernmental Oceanographic Commission (IOC), as a major component of its programme ''Global Investigation of Pollution in the Marine Environment'' (GIPME), maintains a long-standing project on ''Open Ocean Baseline Studies of Trace Contaminants''. Initially, the Atlantic Ocean and trace metals were selected. Four deep-water stations in the Cape Basin, Angola Basin, Cape Verde Abyssal Plain and Seine Abyssal Plain were regularly sampled for at least 36 depths. Additional samples were taken between stations. Samples were distributed to participants and a similar number of additional laboratories. As a central part of our own contribution to the project, we determined the trace heavy metals manganese, nickel, copper, zinc and lead and the lighter selenium by total-reflection X-ray fluorescence analysis. For the TXRF, the pre-enrichment of the trace metals and the separation from the salt matrix were performed by complexation with sodium dibenzyldithiocarbamate and reverse-phase chromatography. Generally, very low levels of trace elements were found in filtered and unfiltered water samples from these remote areas of the open Atlantic Ocean. Typical examples of the distributions of trace metal concentrations on depth profiles from the four deep-water stations as well as intercomparisons between the stations are presented. (author)

  5. Determination of sulfur dioxide in ambient air and in industrial stack using X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Sumitra, T.; Chankow, N.; Punnachaiya, S.; Laopaibul, R.

    1988-01-01

    Sulfur dioxide is a major air pollutant of concern. The gas has to be monitored both in ambient air and in industrial stacks. There are several methods of measuring sulfur dioxide. Standard methods adopted for Thailand are based on chemical methods. These are normally sensitive to light and temperature changes. Therefore a method of collecting air sample and determination of SO 2 by X-ray fluorescence technique was developed. Air sampling was done by an in-house low cost air sampler using automobile battery, dependency on a.c. source was thus avoided. The air pump has a flow rate between 0.2-1.5 liters/minute and draw about 0.6 A from a 12 V battery. SO 2 was collected on 37 mm filters impregnated with 5% sodium carbonate. This method could detect SO 2 from 10 μg up. The method has been checked by interlaboratory comparison. Field test has also been performed at some tobacco curing plants in Amphoe Sansai, Changwat Chiengmai, both in ambient air and in stacks. The results were found to be satisfactory and comparable with the standard methods

  6. Element determination in natural biofilms of mine drainage water by total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mages, Margarete; Tuempling, Wolf von Jr.; Veen, Andrea van der; Baborowski, Martina

    2006-01-01

    Human impacts like mining activities lead to higher element concentration in surface waters. For different pollution levels, the consequences for aquatic organisms are not yet investigated in detail. Therefore, the aim of this investigation is to determine the influence of mining affected surface waters on biofilms. Elements like heavy metals can be absorbed on cell walls and on polymeric substances or enter the cytoplasm of the cells. Thus, they are important for the optimization of industrial biotechnological processes and the environmental biotechnology. Beyond this, biofilms can also play an important role in wastewater treatment processes and serve as bioindicators in the aquatic environment. The presented total reflection X-ray fluorescence spectroscopic investigation was performed to compare the element accumulation behavior of biofilms grown on natural or on artificial materials of drainage water affected by former copper mining activities. A high salt and heavy metal pollution is characteristic for the drainage water. For an assessment of these results, samples from stream Schlenze upstream the confluence with the drainage water, a small tributary of the Saale River in central Germany, were analyzed, too

  7. Separation and determination of arsenic and selenium in natural water samples by energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Moreira, Silvana; Gregorio, Mauricio Abud

    2002-01-01

    This work had as main objective to study a method for separation and determination of Arsenic (III) and (V), and Selenium (IV) and (VI) present in aqueous solutions at trace level. For this purpose a preconcentration method based on the adsorption of the elements in activated charcoal loaded with zirconium (ZrC * ) was used. The ion As (III) was better absorbed onto 200 mg ZrC * in pH 8, while, the ion As (V) presented better results when the absorption was carried out onto 100 mg ZrC * with the pH adjusted for 2. The ions Se (IV) and Se (VI) presented a better absorption when the solutions were adjusted for pH 4, but with different masses of ZrC * , 200 mg for Se (IV) and for Se (VI) just 100 mg. The detection limits obtained by the X-ray fluorescence were 0.050 mg.L -1 and 0.009 mg.L -1 for As (III) and As (V), respectively. In the case of selenium the limits were 0.011 mg.L -1 and 0.016 mg.L -1 for Se (IV) and (VI) species, respectively. The errors obtained by this methodology were smaller than 2% for the ion As (III) and smaller than 1% for As (V), Se (IV) and Se (VI). (author)

  8. Determination of Vanadium and Titanium in oil using aqueous calibration curves by X-ray fluorescence

    International Nuclear Information System (INIS)

    Ayala, R.E.; Letona, S.M.

    1989-10-01

    It is shown that the determination of minor elements in oil can be realized with high accuracy and precision using standard aqueous solutions. The relationship Ii/(Ia-Io)=KCi must be used, where Ii concentration Ci, Ia is the intensity of the scattered radiation of 5.894 keV from a Fe-55 radioisotope source and K is a constant. Io is calculated through the equation Ii/K(Ia-Io)=Ji/K(Ja-Io), where Ii and Ia are measured from the spectrum of an aqueous standard; Ji and Ja are measured from the spectrum of an oil sample, which has a concentration of the element i equal to that in the aqueous solution. The relationship Ii/Ia=KCi, used in previous work, does not include the term Io, therefore it must be used only for semi-quantitative analysis. An experiment on the determination of vanadium and titanium in standard oils (CONOSTAN S-12 and CONOSTAN S-21) confirmed this derivation. Reproducibility equal or below 5 and accuracy of 7 were achieved. (author)

  9. X-ray microtome by fluorescence tomography

    CERN Document Server

    Simionovici, A S; Guenzler, F; Schrör, C; Snigirev, A; Snigireva, I; Tümmler, J; Weitkamp, T

    2001-01-01

    The X-ray fluorescence microtomography method is presented, which is capable of virtually slicing samples to obtain cross-sections of their inner structure. High precision experimental results of fluo-tomography in 'pencil-beam' geometry with up to 1.2 mu m resolution are described. Image reconstructions are based on either a simplified algebraic reconstruction method (ART) or the filtered back-projection method (FBP). Phantoms of inhomogeneous test objects as well as biological samples are successfully analyzed.

  10. Polarized X-ray excitation for scatter reduction in X-ray fluorescence computed tomography.

    Science.gov (United States)

    Vernekohl, Don; Tzoumas, Stratis; Zhao, Wei; Xing, Lei

    2018-05-25

    X-ray fluorescence computer tomography (XFCT) is a new molecular imaging modality which uses X-ray excitation to stimulate the emission of fluorescent photons in high atomic number contrast agents. Scatter contamination is one of the main challenges in XFCT imaging which limits the molecular sensitivity. When polarized X-rays are used, it is possible to reduce the scatter contamination significantly by placing detectors perpendicular to the polarization direction. This study quantifies scatter contamination for polarized and unpolarized X-ray excitation and determines the advantages of scatter reduction. The amount of scatter in preclinical XFCT is quantified in Monte Carlo simulations. The fluorescent X-rays are emitted isotropically, while scattered X-rays propagate in polarization direction. The magnitude of scatter contamination is studied in XFCT simulations of a mouse phantom. In this study, the contrast agent gold is examined as an example but a scatter reduction from polarized excitation is also expected for other elements. The scatter reduction capability is examined for different polarization intensities with a monoenergetic X-ray excitation energy of 82 keV. The study evaluates two different geometrical shapes of CZT detectors which are modeled with an energy resolution of 1 keV FWHM at an X-ray energy of 80 keV. Benefits of a detector placement perpendicular to the polarization direction are shown in iterative and analytic image reconstruction including scatter correction. The contrast to noise ratio (CNR) and the normalized mean square error (NMSE) are analyzed and compared for the reconstructed images. A substantial scatter reduction for common detector sizes was achieved for 100% and 80% linear polarization while lower polarization intensities provide a decreased scatter reduction. By placing the detector perpendicular to the polarization direction, a scatter reduction by factor up to 5.5 can be achieved for common detector sizes. The image

  11. Determination of Nb in ZrO2 matrix using Wavelength Dispersive X-Ray Fluorescence (WDXRF) technique

    International Nuclear Information System (INIS)

    Jha, S.N.; Kapoor, S.K.; Malhotra, S.K.; Kaimal, R.; Kamat, M.J.; Sehra, J.C.

    1998-09-01

    A Wavelength Dispersive X-Ray Fluorescence (WDXRF) method is described for the estimation of niobium in ZrO 2 matrix in the concentration range of 0.5 to 35%. Analysis of Nb is desired during the reclamation of zirconium from Zr-2.5% Nb scrap. Zr-2.5% Nb is used in water cooled nuclear power reactors on account of high creep resistance and strength. For the reclamation of these metals from the scrap, chlorination is done to produce mixed chloride. The mixed chloride is treated to obtain individual chloride for eventually converting to respective metal. Analysis is required to ascertain purity of these metals reclaimed from the scrap. Primary x-rays from gold target x-ray tube were used to excite the K lines of Nb. A linear relation has been found between the intensity of Nb-Kα 1,2 line and concentration in the above range and the detection limit was 0.03% for 10 seconds counting time. (author)

  12. X-ray fluorescence (XRF) set-up with a low power X-ray tube

    International Nuclear Information System (INIS)

    Gupta, Sheenu; Deep, Kanan; Jain, Lalita; Ansari, M.A.; Mittal, Vijay Kumar; Mittal, Raj

    2010-01-01

    The X-ray fluorescence set-up with a 100 W X-ray tube comprises a computer controlled system developed for remote operation and monitoring of tube and an adjustable stable 3D arrangement to procure variable excitation energies with low scattered background. The system was tested at different filament currents/anode voltages. The MDL of the set-up at 0.05-1.00 mA/4-12 kV is found ∼(1-100) ppm for K and L excitations and ∼(200-700) ppm for M excitations of elements and improves with filament current and anode voltage. Moreover, L measurements for Sm and Eu at five K X-ray energies of elements(Z=29-40) and analytical determination in some synthetic samples were undertaken.

  13. Determination of elements in bone of tuberculous-arthritis patients by radioisotope X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Akyuez, T.; Bassari, A.; Akyuez, S.

    1998-01-01

    The quantitative analysis of the human femoral bone of 17 tuberculosis-arthritis (Koch-arthritis) patients (9 males and 8 females) in the age range of 45-65, for Ca, P, Zn, Sr, Ba, La and Ce were performed by using radioisotope energy dispersive X-ray fluorescence (EDXRF) and the results were compared with those of 12 healthy control groups (8 males and 4 females) in the range of 37-58. The results indicate that the concentrations of P, Ca and Sr in the control group are higher than those in the patient group, while the concentrations of Zn, Ba, La and Ce are not significantly different. (author)

  14. Total reflection X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Michaelis, W.; Prange, A.

    1987-01-01

    In the past few years, total reflection X-ray flourescence analysis (TXRF) has found an increasing number of assignments and applications. Experience of trace element analysis using TXRF and examples of applications are already widespread. Therefore, users of TXRF had the opportunity of an intensive exchange of their experience at the 1st workshop on total reflection X-ray fluorescence analysis which took place on May 27th and 28th 1986 at the GKSS Research Centre at Geesthacht. In a series of lectures and discussions dealing with the analytical principle itself, sample preparation techniques and applications as well as comuter programs for spectrum evaluation, the present state of development and the range of applications were outlined. 3 studies out of a total of 14 were included separately in the INIS and ENERGY databases. With 61 figs., 12 tabs [de

  15. Silicon lithium detector for x ray fluorescence

    International Nuclear Information System (INIS)

    Rodriguez Cabal, A. E.; Diaz Garcia, A.; Noriega Scull, C.; Martinez Munoz, O.; Diaz Cepeda, R.

    1997-01-01

    The Silicon Lithium detector is the system for the detection of nuclear radiation. It transforms the charge that was produced inside of Silicon material as a result of the incidence of particles and X rays, in voltage pulses at the output of the preamplifier. In this work was made the adjustment of the technological process of manufacture of the detector. Also was made the design and construction of the cryostat and preamplifier and then the validation of the system in a Cuban Dewar. The system, which was made for the first time in our country, has an energy resolution of 185 eV for the Fe-55 source (E=5.9 KeV), which has permitted its implementation in energy dispersive X ray fluorescence. (author) [es

  16. Determination of trace elements in freshwater rotifers and ciliates by total reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Woelfl, S.; Óvári, M.; Nimptsch, J.; Neu, T. R.; Mages, M.

    2016-02-01

    Element determination in plankton is important for the assessment of metal contamination of aquatic environments. Until recently, it has been difficult to determine elemental content in rotifers or ciliates derived from natural plankton samples because of the difficulty in handling and separation of these fragile organisms. The aim of this study was to evaluate methods for separation of rotifers and large ciliates from natural plankton samples (μg range dry weight) and subsequent analysis of their elemental content using total-reflection X-ray fluorescence spectrometry (TXRF). Plankton samples were collected from different aquatic environments (three lakes, one river) in Chile, Argentina and Hungary. From one to eighty specimens of five rotifer species (Brachionus calyciflorus, Brachionus falcatus, Asplanchna sieboldii, Asplanchna sp., Philodina sp.) and four to twelve specimens of one large ciliate (Stentor amethystinus) were prepared according to the dry method originally developed for microcrustaceans, and analysed by TRXF following in situ microdigestion. Our results demonstrated that it possible to process these small and fragile organisms (individual dry mass: 0.17-9.39 μg ind- 1) via careful washing and preparation procedures. We found species-dependent differences of the element mass fractions for some of the elements studied (Cr, Mn, Fe, Ni, Cu, Zn, As, Pb), especially for Cu, Fe and Mn. One large rotifer species (A. sieboldii) also showed a negative correlation between individual dry weight and the element content for Pb, Ni and Cr. We conclude that our application of the in situ microdigestion-TRXF method is suitable even for rotifers and ciliates, greatly expanding the possibilities for use of plankton in biomonitoring of metal contamination in aquatic environments.

  17. Determination of trace element and heavy metal in black tea and tea leaves using x-ray fluorescence

    International Nuclear Information System (INIS)

    Salih, Mohamed Abualgasim Abdalhakam

    2016-08-01

    The aim of this study was to provide information about the trace element and heavy metals concentrations in black tea and tea leaves. 23 different samples were collected from the Sudanese local market. The collected samples were characterized as the most common used items in Sudan. The concentration of trace and heavy elements were determined using x-ray fluorescence (X RF) technique. The standard reference materials (IAEA-V-10) and hay (powder) were used to evaluate the accuracy of the analytical result. The measured values were found in agreement with the certified values. The elements determined were K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb, and Sr. The average concentration of the elements is black tea were 2277.43, 7245.71, 1.11, 1025.29, 334.29, 6.88, 11.24, 9.47, 1.02, 7.08, 97.4 and 63.21 respectively while the average concentration of the elements in leaves tea were 2644.44, 8805.56, 1.02, 571.81, 295.44, 6.19, 10.69, 9.26, 0.91, 13.42, 63.03 and 67.14 respectively. The results showed an increase in the concentration of some elements such as calcium, chromium, manganese, iron, nickel, copper, zinc, bromine, rubidium and strontium (22500, 6.75, 48.9, 194, 4.37, 9,77, 24.9, 8.23, 7.79, 40,9) ppm respectively compared to certified values. Correlation between concentration of certain element and cluster analysis were preformed and the results compared with values of literature and the concentrations of some elements found to be similar.(Author)

  18. Development of an absolute x-ray fluorescence technique and high accuracy analytical methods for the determination of metals in catalytic materials

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Parker, W.C.

    1982-09-01

    A technique to produce characteristic x-rays by direct beta excitation for x-ray fluorescence analysis is presented. This is carried out by the introduction of 100 uCi of Pm-147 or Ni-63 to a small sample, which is placed directly in the window of a modified Si(Li) semiconductor. Corrected intensities are only given at 300 seconds for synthetic standards oscillating within the range 22 3 was used, to which the radioisotope was directly added. Preliminary results of the determination of eleven different radionuclides by means of an elementary x-ray analysis by using a new analytical technique, are discussed. In this technique the radioisotope and the sample are directly mixed, then this source-sample in the detector window and is protected from contamination with a thin plastic film. Future and possible applications of this technique are presented

  19. Determinations of silicon and phosphorus in rice planted on a district of high incidence of amyotrophic lateral sclerosis by neutron activation and X-ray fluorescence analyses

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, Yoshihiko; Ishikawa, Teruumi; Kusakabe, Toshio; Katsurayama, Kousuke (Kinki Univ., Higashi-Osaka, Osaka (Japan)); Iwata, Shiro

    1989-12-01

    Silicon and phosphorus contents in polished and unpolished rice planted on a district of high incidence of amyotrophic lateral sclerosis (ALS) have been determined by neutron activation and X-ray fluorescence methods, and compared with those from control areas. In the neutron activation analysis, {beta}-ray spectra of {sup 32}P produced by the {sup 31}P(n, {gamma}){sup 32}P reaction on polished and unpolished rice were measured with a low background {beta}-ray spectrometer. In the X-ray fluorescence analysis, characteristic X-ray were analyzed with a wavelength dispersive X-ray fluorescence spectrometer. Silicon contents in polished and unpolished rice from the ALS area are 42 {mu}g.g{sup -1} and 370 {mu}g.g{sup -1}, respectively, and the corresponding phosphorus contents are 1210 {mu}g.g{sup -1}, and 3370 {mu}g.g{sup -1}, respectively. The data for ALS area are equal to those for the control area within atandard deviation. (author).

  20. Application of X-ray fluorescence analysis in environmental research

    International Nuclear Information System (INIS)

    Kliment, V.; Kliman, J.; Turzo, I.

    1978-01-01

    A description is presented of the X-ray fluorescence analysis principles and of its possibilities in the study of environmental pollution impact. Experiments with X-ray fluorescence analysis using 241-Am and a Ge(Li) semiconductor detector are discussed. The reproducibility of determinations in dependence on the sample preparation and the evaluation of peak surfaces of characteristic radiation is shown. The dependence of the peak surface on the elemental contents in the sample was linear. Detection limits of the investigated elements ranged in tenths of μg for 300 s measurement. (author)

  1. X-ray fluorescence microtomography analyzing prostate tissues

    International Nuclear Information System (INIS)

    Pereira, Gabriela R.; Rocha, Henrique S.; Calza, Cristiane; Lopes, Ricardo T.

    2009-01-01

    The objective of this work is to determine the elemental distribution map in reference samples and prostate tissue samples using X-Ray Fluorescence Microtomography (XRFCT) in order to verify concentrations of certain elements correlated with characteristics observed by the transmission microtomography. The experiments were performed at the X-Ray Fluorescence Facility of the Brazilian Synchrotron Light Laboratory. A quasi-monochromatic beam produced by a multilayer monochromator was used as an incident beam. The transmission CT images were reconstructed using filtered-back-projection algorithm, and the XRFCT images were reconstructed using filtered-back-projection algorithm with absorption corrections. (author)

  2. Limestone rocks analysis by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Izquierdo M, G.; Ponce R, R.; Vazquez J, J.

    1996-01-01

    By request of a private company, employing basically X-ray fluorescence analysis (X RF), was established a fast and accurate method for the analysis of the major elements in limestone rocks. Additionally, for complementing analysis was determined by ion chromatography, the chlorides appearance and by atomic absorption of sodium. By gravimetry, was determined the losses by ignition and the alpha quartz. (Author)

  3. Determination of As concentration in earthworm coelomic fluid extracts by total-reflection X-ray fluorescence spectrometry

    Science.gov (United States)

    Allegretta, Ignazio; Porfido, Carlo; Panzarino, Onofrio; Fontanella, Maria Chiara; Beone, Gian Maria; Spagnuolo, Matteo; Terzano, Roberto

    2017-04-01

    Earthworms are often used as sentinel organisms to study As bioavailability in polluted soils. Arsenic in earthworms is mainly sequestrated in the coelomic fluids whose As content can therefore be used to asses As bioavalability. In this work, a method for determining As concentration in coelomic fluid extracts using total-reflection X-ray fluorescence spectrometry (TXRF) is presented. For this purpose coelomic fluid extracts from earthworms living in three polluted soils and one non-polluted (control) soil have been collected and analysed. A very simple sample preparation was implemented, consisting of a dilution of the extracts with polyvinyl alcohol (PVA) using a 1:8 ratio and dropwise deposition of the sample on the reflector. A detection limit of 0.2 μg/l and quantification limit of 0.6 μg/l was obtained in the diluted samples, corresponding to 2 μg/l and 6 μg/l in the coelomic fluid extracts, respectively. This allowed to quantify As concentration in coelomic fluids extracted from earthworms living in soils polluted with As at concentrations higher than 20 mg/kg (considered as a pollution threshold for agricultural soils). The TXRF method has been validated by comparison with As concentrations in standards and by analysing the same samples by ICP-MS, after acid digestion of the sample. The low limit of detection, the proven reliability of the method and the little sample preparation make TXRF a suitable, cost-efficient and "green" technique for the analysis of As in earthworm coelomic fluid extracts for bioavailability studies.

  4. Correction for the interference of strontium in the determination of uranium in geologic samples by X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Bayon, A.

    1981-01-01

    A suitable empirical algorithm for the correction for the spectral interference of the SrKα on the ULα line has been derived. It works successfully for SrO concentrations up to 8% with a minimum detectable limit of 20 ppm U 3 O 8 . X-ray spectrometry procedure allows also the determination of the SrO contents of the samples. A program in BASIC language for data reduction has been written. (Author) 3 refs

  5. Effect of Electric Voltage and Current of X-ray Chamber on the Element inthe Zirconium Alloy Analysis X-ray by X-ray Fluorescence

    International Nuclear Information System (INIS)

    Yusuf-Nampira; Narko-Wibowo, L; Rosika-Krisnawati; Nudia-Barenzani

    2000-01-01

    The using of x-ray fluorescence in the chemical analysis depend heavilyon the parameters of x-ray chamber, for examples : electric voltage andelectric current. That parameter give effect in the result of determine ofSn, Cr, Fe and Ni in the zirconium alloy. 20 kV electric voltages are used onthe Mo x-ray chamber shall product x-ray of zirconium in the sample materialcan give effect in the stability of the analysis result (deviation more than5%). The result of analysis of elements in the zirconium alloy shall givedeviation less than 5% when using of electric voltage of the x-ray chamberless than 19 kV. The sensitivity of analysis can be reached by step upelectric current of x-ray chamber. (author)

  6. Establishment of an analytical procedure for the determination of niobium and tantalum in minerals containing these elements using X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Nguyen Xuan Chien

    2003-01-01

    The study of determination of niobium, tantalum in mineral and tin slags using X-ray fluorescence spectrometry was carried out. Analytical samples of powder and pellet were prepared. the interference of the major accompanied elements in sample with the determination of niobium and tantalum was also studied. The analysis of niobium and tantalum in mineral and in tin slags samples was given in this work. (author)

  7. Submicron, soft x-ray fluorescence imaging

    International Nuclear Information System (INIS)

    La Fontaine, B.; MacDowell, A.A.; Tan, Z.; White, D.L.; Taylor, G.N.; Wood, O.R. II; Bjorkholm, J.E.; Tennant, D.M.; Hulbert, S.L.

    1995-01-01

    Submicron fluorescence imaging of soft x-ray aerial images, using a high resolution fluorescent crystal is reported. Features as small as 0.1 μm were observed using a commercially available single-crystal phosphor, STI-F10G (Star Tech Instruments Inc. P. O. Box 2536, Danbury, CT 06813-2536), excited with 139 A light. Its quantum efficiency was estimated to be 5--10 times that of sodium salicylate and to be constant over a broad spectral range from 30 to 400 A. A comparison with a terbium-activated yttrium orthosilicate fluorescent crystal is also presented. Several applications, such as the characterization of the aerial images produced by deep ultraviolet or extreme ultraviolet lithographic exposure tools, are envisaged

  8. Rapid qualitative determination of main components in archeological samples by radioisotope-excited X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Shenberg, C.; Boazi, M.

    1975-01-01

    Archeological specimen were examined by the radioisotope-excited X-ray method to determine their chemical composition. Individual K and L X-rays of Fe, Ni, Cu, Zn, Pb, Mo, Ag, In, Sn and Ba were induced by using 241 Am - I and 241 Am- Tm source- target assemblies. A lithium drifted silicone diode coupled to a 400-channel analyzer was used for detection. No sample preparation was required and all the elements were measured simultaneously in 40 min counting time. The use of different targets coupled with only one primary source makes this technique simple, versatile and economical. The target materials are suitable for exciting K and L X-rayd from potassium to uranium. In addition, the targets, as monoenergetic secondary sources, minimize the background effect. (T.G.)

  9. Study of the experimental parameters for the determination of Ca, Cr, Cu, Fe, Mn and Ni on nuclear grade UO2 by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Salvador, V.L.R.

    1982-01-01

    An analytical method for the simultaneous determinations of low concentrations of Ca, Cr, Cu, Fe, Mn and Ni on the nuclear grade UO 2 by X-ray fluorescence technique, without the use of chemical treatment, is described. The optimization of the experimental conditions was established on the X-ray fluorescence spectrometer and a low limit of detection (4 - 7 μg/gU) was achieved which satisfies the requirement in the nuclear fuel specification. The samples were prepared in the form of double layer pressed pellets using boric acid as a binding agent. The characteristic first order K sub(α) line intensity of each minor component was measured and the values of its concentrations were deduced using respective standard calibrations curves. The precision, accuracy and acceptability of the method were determined for all elements. The values of the precision are in the range of 2 - 10% and the accuracy are lower than 7%. (Author) [pt

  10. X-ray fluorescence method for trace analysis and imaging

    International Nuclear Information System (INIS)

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide tace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and instruments for trace characterization with a scanning x-ray microprobe are described. (author)

  11. Inorganic elements determination in human and animal whole blood samples by X-ray fluorescence technique (EDXRF)

    International Nuclear Information System (INIS)

    Redigolo, Marcelo Miyada

    2011-01-01

    Blood is a suspension of cells contained in a complex liquid called plasma. The term 'whole blood' refers to samples with both solid and liquid parts. Inorganic elements are responsible for essential functions, such as osmotic regulation, cardiac frequency and contractibility, blood clotting and neuromuscular excitability. The determination of inorganic elements in corporeal fluids such as blood, serum, plasma, tissue and urine is used as a monitor for a part or the whole organism. In this work, the X-Ray fluorescence technique (EDXRF) was used for the determination of inorganic elements in whole blood samples from humans and animals (golden hamsters, Mesocricetus auratus and crioula breed horses, Equus caballus). The reference intervals of Na (1788 - 1826 μg g'- 1 ), Mg (63 - 75 μg g -1 ), P (602 - 676 μg g -1 ), S (1519 - 1718 μg g -1 ), Cl (2743 - 2867 μg g -1 ), K (1508 - 1630 μg g -1 ), Ca (214 - 228 μg g'- 1 ), Cu (4 -6 μg g -1 ) e Zn (1 - 3 μg g'- 1 ) were determined for human blood. The reference intervals, for golden hamster blood were found to be: Na (1714 - 1819 μg g -1 ), Mg (51 - 79 μg g -1 ), P (970 - 1080 μg g -1 ), S (1231 - 1739 μg g -1 ), Cl (2775 - 2865 μg g -1 ), K (1968 - 2248 μg g -1 ), Ca (209 - 257 μg g-1), Cu (4 - 6 μg g -1 ) e Zn (3 - 5 μg g -1 ). The reference intervals, for crioula breed horse blood, showed to be: Na (1955 - 2013 μg g -1 ), Mg (51 - 75 μg g -1 ), P (443 - 476 μg g -1 ), S (1038 - 1140 μg g - '1), Cl (2388 - 2574 μg g -1 ), K (1678 - 1753 μg g -1 ), Ca (202 - 213 μg g -1 ), Cu (4,1 - 4,5 μg g -1 ) e Zn (2,0 - 2,2 μg g -1 ). Comparative study between NAA and EDXRF, both techniques showed the same performance for the analyses of biological matrices. The results contribute for the establishment of reference intervals for the Brazilian healthy population and the referred animal species. (author)

  12. Simultaneous determination of Hg, Pb, As, Cu, Zn and Ni in natural waters (with humic material) by energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Morales S, E.A.; Zepeda L, E.

    1988-05-01

    Standardization of a method for simultaneous quantification of Hg, Pb, As, Cu, Zn and Ni in natural waters with humic acid contents was carried out. APDC for complexing free ions and silica gel as adsorber of metallic humates and further filtration were employed. X-ray fluorescence analysis was performed on filters. Good results were found for silica-gel as adsorber. Detection limits of 4 nanograms/milliliter were determined. (author)

  13. Preparatory studies for the on-line determination of zinc content in zinc ore slurries by radioisotope excited X-ray fluorescence

    International Nuclear Information System (INIS)

    Donhoffer, D.K.

    1977-01-01

    Laboratory tests were carried out to prove the feasibility of determination of Zn-content in zinc ore slurries by isotope excited x-ray fluorescence. Matrix effects were investigated on dry samples. A slurry testloop was built and measurements on slurries were made. The results indicated that the measurement on Zn in ore slurries can be made with a precision of 0,05% Zn. A working equation for interpretation of the measurements is derived. (author)

  14. In vivo X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Ahlgren, L.

    1980-02-01

    Measurements on five occupationally exposed persons have shown that it is possible to use X-ray fluorescence analysis for in vivo measurements of lead in the skeleton. The technique for calibrating in vivo X-ray fluorescence measurements of lead in bone tissue has been studied in detail and a two-component phantom simulating the bone and the soft tissue parts of the finger constructed. The technique has been used for in vivo measurements on 22 occupationally exposed persons. The minimum detectable concentration of lead in fingerbones was found to be around 20 μg x g -1 . The lead concentrations in their skeletons and blood were compared: the correlation was poor. The variations in lead concentrations in the skeleton have been studied in occupationally exposed persons and in samples from archaeological skeletons. The sensitivity and the minimum detectable concentration of cadmium in the kidney cortex in in vivo measurements has been studied by measurements on kidney models. The minimum detectable concentration was 20 μg x g -1 at a skin-kidney distance of 30 mm and 40 μg x g -1 at 40 mm. Five persons occupationally exposed were studied. (Author)

  15. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Amberger, Martin A.; Hoeltig, Michael; Broekaert, Jose A.C.

    2010-01-01

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL -1 . As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL -1 of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 μg g -1 for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al 2 O 3 , powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective samples over a

  16. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  17. Determination of copper in geological materials by X-ray fluorescence; Determinacion de cobre en materiales geologicos mediante fluorescencia de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M; Bayon, A

    1981-07-01

    X-ray fluorescence has been applied to the determination of copper content of geological materials in the concentration range of 0.01 to % CuO. A molybdenum target tube Is used, samples being presented in finely-ground powder form. Various methods for the correction for background and Instrumental copper interferences have been considered. To correct for matrix effects different tube scattered primary radiations have been tested as references or internal standards. MoK(41 - (C) provides the most suitable results. The use of influence empirical coefficients for the effect of iron on copper and of mass absorption coefficients has also been considered. For samples with a high content of lead, several procedures to correct for I t s influence have been investigated. Comparison between data obtained by X-ray fluorescence and wet-chemical techniques indicated good agreement. (Author) 6 refs.

  18. Determination of trace metals in sea waters of the albanian coast by energy-dispersive x-ray fluorescence

    International Nuclear Information System (INIS)

    Civici, N.

    1994-01-01

    Preconcentration of trace transition and heavy metal ions by precipitation with APDC has been combined with energy-dispersive X-ray fluorescence for environmental sea water analysis. The preconcentration procedure implies adding of 500 μg Mo ion and 10 ml of 1 % water solution of APDC to a 500 ml water sample at pH 4, filtering off on a Millipore filter and analyzing after drying. Realistic detection limits are at 1 μg * l -1 level and precision varies between 10 - 25% at about 5 μg * l -1 level, depending on the element. Eleven sea water samples, covering Albanian Adriatic and Ionian coast, are analyzed for trace metal ions. (author) 8 refs.; 2 figs.; 5 tabs

  19. Determination of heavy metals at traces level in leached samples by energy dispersive x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Simabuco, Silvana M.; Nascimento Filho, Virgilio F. do; Inacio, Graziela R.; Navarro, Angela N.

    1996-01-01

    In landfill solid residues are disposed in the soil. When made based on technical criteria and specifically operation patterns a safe confinement is warranted according to environmental and public health protection. However, when the disposal is made by a random and unsuitable way serious problems can be caused as groundwater and superficial water contamination through leach action, indicating the usefulness of monitoring landfills. In this way energy dispersive X-ray fluorescence analysis with radioisotopic excitation was applied to evaluate the concentrations of heavy metals at trace levels in leached samples from the Americana City Landfill with pre-concentration of the elements by a non-specific precipitating agent, called ammonium pyrrolidine dithiocarbamate (APDC). (author)

  20. Study of the effect of some of the experimental parameters on the x-ray fluorescence determination of traces of hafnia in high purity zirconia

    International Nuclear Information System (INIS)

    Qurbani, J.M.; Khanna, P.P.; Agrawal, R.M.

    1974-01-01

    The effect of the following parameters : (i) analytical lines HfLsub(αsub(1)) or HfLsub(βsub(1,6)) or HfLsub(βsub(2)) (ii) detectors - scintillation or gas flow proportional (iii) collimators - fine or coarse (iv) x-ray tube voltage, current and power (v) order of diffraction : I or II of analysing crystal LiF (200), on the precision of the results and the sensitivity of the method in the x-ray fluorescence determination of traces of hafnia in high purity zirconia, has been studied. Philips semiautomatic x-ray spectrometer PW 1220 with associated equipment has been used. Synthetic standards containing HfO 2 in the range 20 ppm to 1 % in ZrO 2 , presented as double layer pellets have been used. LiF (200) analysing crystal, tungsten target x-ray tube, automatic pulse height selection and pulse height discrimination were used in all the cases. The set - 'HfLsub(βsub(1,6)) analytical line, fine collimator and gas flow proportional counter detector' - gave the best performance. (author)

  1. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    Science.gov (United States)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  2. Determination of Cr2O3 in chrome-tanned leather by radionuclide-excited X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Melich, M.; Palagyi, S.; Kern, M.

    1989-01-01

    Preliminary results on the determination of Cr 2 O 3 in chrome-tanned leather by measuring the content of Cr by means of radionuclide-excited XRF analysis are reported. For excitation a 3.7 GBq 238 Pu source was used and the characteristic K X-rays of Cr were detected with a planar Si(Li) detector. Both smooth and rough sides of the leather were analyzed directly or with a pair of V/Ti balanced filters. A fairly good correlation was found between Cr Kx counts of the rough side and the Cr 2 O 3 concentrations determined chemically in the range of 3.5 to 6.0% Cr 2 O 3 . The method renders possible a rapid and non-destructive determination of Cr 2 O 3 in various leather samples. (author)

  3. Review of X-ray Tomography and X-ray Fluorescence Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Shear, Trevor A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    This literature review will focus on both laboratory and synchrotron based X-ray tomography of materials and highlight the inner workings of these instruments. X-ray fluorescence spectroscopy will also be reviewed and applications of the tandem use of these techniques will be explored. The real world application of these techniques during the internship will also be discussed.

  4. In situ determination of K, Ca, S and Si in fresh sugar cane leaves by handheld Energy Dispersive X-Ray Fluorescence Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Marcelo B.B.; Adame, Andressa; Almeida, Eduardo de; Brasil, Marcos A.S.; Krug, Francisco J., E-mail: fjkrug@cena.usp.br [Centro de Energia Nuclear na Agricultura, Piracicaba, SP (Brazil); Schaefer, Carlos E.G.R. [Departamento de Solos, Universidade Federal de Viçosa, MG (Brazil)

    2018-05-01

    A portable energy dispersive X-ray fluorescence spectrometer was evaluated in the in situ analysis of fresh sugar cane leaves for real time plant nutrition diagnosis. Fresh leaf fragments (n = 10 sugar cane varieties; 20 fragments per leaf; 2 measurement sites per fragment) were irradiated and the averaged data from X-ray characteristic emission lines intensities (for K, Ca, S and Si Kα lines) were in close agreement with mass fraction data obtained by a validated comparative method. The linear correlation coefficients (r) ranged from 0.9575 for Ca to 0.9851 for Si. The obtained limits of detection were at least two-fold lower than the critical nutrient levels. Manganese can also be properly determined, but validation still requires more robust calibration models. The proposed method is a straightforward approach towards the fast evaluation of the nutritional profile of plants avoiding time-consuming steps, which involve drying, grinding, weighing, and acid digestion. (author)

  5. Method and device for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Jagoutz, E.; Palme, C.

    1978-01-01

    In the x-ray fluorescence analyzer the useful signal can be completely separated from the spurious signals, and especially the pulse can be determined. For this purpose the output of the radiation detector is connected with a multichannel pulse height discriminator. The measured signal determined in the pulse heigth discriminator may be indicated by a visual display or processed by a computer (coincidence circuits). (DG) [de

  6. X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation

    International Nuclear Information System (INIS)

    Hodoroaba, V.-D.; Radtke, M.; Vincze, L.; Rackwitz, V.; Reuter, D.

    2010-01-01

    X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses.

  7. Worldwide proficiency test for X ray fluorescence laboratories PTXRFIAEA/05 determination of minor and trace elements in marine sediment

    International Nuclear Information System (INIS)

    2009-01-01

    The proficiency test (code PTXRFIAEA05) was the fifth worldwide exercise organized by the IAEA Seibersdorf Laboratories in order to assist X ray fluorescence laboratories in assessment and improvement of their analytical performance. The test was carried out within the IAEA Project 1.4.3.4 (D.3.03) on Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of the project was to enhance capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health, agriculture, and in monitoring and evaluation of environmental pollution. Marine sediment test samples with established homogeneity and well characterized known target values of the mass fractions of analytes were distributed to participating laboratories. The laboratories were requested to analyze the sample using established techniques following their analytical procedures. Based on the results of the proficiency test presented in the report each participating laboratory should assess its analytical performance results by using the specified criteria and, if appropriate, to identify discrepancies, and to correct relevant analytical procedures. The next proficiency test exercise will be executed in 2009

  8. Standard test method for determination of low concentrations of uranium in oils and organic liquids by X-ray fluorescence

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers the steps necessary for the preparation and analysis by X-ray fluorescence (XRF) of oils and organic solutions containing uranium. Two different preparation techniques are described. 1.2 The procedure is valid for those solutions containing 20 to 2000 μg uranium per mL as presented to the spectrometer for the solution technique and 200 to 50 000 μg uranium per g for the pellet technique. 1.3 This test method requires the use of an appropriate internal standard. Care must be taken to ascertain that samples analyzed by this test method do not contain the internal standard or that this contamination, whenever present, has been corrected for mathematically. Such corrections are not addressed in this procedure. Care must be taken that the internal standard and sample medium are compatible; that is, samples must be miscible with tri-n-butyl phosphate (TBP) and must not remove the internal standard from solution. Alternatively, a scatter line may be used as the internal standard. 1....

  9. Detection and quantitative determination of heavy metals in electronic cigarette refill liquids using Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Kamilari, Eleni; Farsalinos, Konstantinos; Poulas, Konstantinos; Kontoyannis, Christos G; Orkoula, Malvina G

    2018-06-01

    Electronic cigarettes are considered healthier alternatives to conventional cigarettes containing tobacco. They produce vapor through heating of the refill liquids (e-liquids) which consist of propylene glycol, vegetable glycerin, nicotine (in various concentrations), water and flavoring agents. Heavy metals may enter the refill liquid during the production, posing a risk for consumer's health due to their toxicity. The objective of the present study was the development of a methodology for the detection and quantitative analysis of cadmium (Cd), lead (Pb), nickel (Ni), copper (Cu), arsenic (As) and chromium (Cr), employing Total Reflection X-Ray Fluorescence Spectroscopy (TXRF) as an alternative technique to ICP-MS or ICP-OES commonly used for this type of analysis. TXRF was chosen due to its advantages, which include short analysis time, promptness, simultaneous multi-element analysis capability and minimum sample preparation, low purchase and operational cost. The proposed methodology was applied to a large number of electronic cigarette liquids commercially available, as well as their constituents, in order to evaluate their safety. TXRF may be a valuable tool for probing heavy metals in electronic cigarette refill liquids to serve for the protection of human health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Multielement determination in river-water of Sepetiba Bay tributaries (Brazil) by total reflection X-ray fluorescence using synchrotron radiation

    International Nuclear Information System (INIS)

    Costa, A.C.M.; Castro, C.R.F.; Lopes, R.T.; Anjos, M.J.; Rio de Janeiro State Univ.

    2006-01-01

    Trace elements were determined in the surface waters of tributaries of the Sepetiba Bay, Brazil (Piraque, Ita, Sao Francisco, Guarda, Guandu Mirim, Vala do Sangue and Engenho Novo rivers) by total reflection X-ray fluorescence using synchrotron radiation (SRTXRF). Eighteen trace elements could be determined in the dissolved and the suspended particulate phases: Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr and Pb. The elemental concentration values were compared to the values recommended by the Brazilian legislation. (author)

  11. Determination of low concentrations of thorium in geological materials by X-ray fluorescence; Determinacion de bajas concentraciones de torio en materiales geologicos mediante fluorescencia de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M.; Bayon, A.

    1981-07-01

    An X-ray fluorescence method for the determination of thorium in geological samples down to 2 ppm ThO{sub 2} has been developed. To achieve this determination limit an exposed area of the sample 42.5 mm in diameter is used, working with a molybdenum target tube operated at 90 kV and 30 m A. Corrections for background and line interference of the Rb K{alpha} radiation have been carefully considered and empirical correction coefficients calculated. (Author) 3 refs.

  12. Application of synchrotron radiation to x-ray fluorescence analysis of trace elements

    International Nuclear Information System (INIS)

    Gordon, B.M.; Jones, K.W.; Hanson, A.L.

    1986-08-01

    The development of synchrotron radiation x-ray sources has provided the means to greatly extend the capabilities of x-ray fluorescence analysis for determinations of trace element concentrations. A brief description of synchrotron radiation properties provides a background for a discussion of the improved detection limits compared to existing x-ray fluorescence techniques. Calculated detection limits for x-ray microprobes with micrometer spatial resolutions are described and compared with experimental results beginning to appear from a number of laboratories. The current activities and future plans for a dedicated x-ray microprobe beam line at the National Synchrotron Light Source (NSLS) of Brookhaven National Laboratory are presented

  13. Fluorescent scanning x-ray tomography with synchrotron radiation

    Science.gov (United States)

    Takeda, Tohoru; Maeda, Toshikazu; Yuasa, Tetsuya; Akatsuka, Takao; Ito, Tatsuo; Kishi, Kenichi; Wu, Jin; Kazama, Masahiro; Hyodo, Kazuyuki; Itai, Yuji

    1995-02-01

    Fluorescent scanning (FS) x-ray tomography was developed to detect nonradioactive tracer materials (iodine and gadolinium) in a living object. FS x-ray tomography consists of a silicon (111) channel cut monochromator, an x-ray shutter, an x-ray slit system and a collimator for detection, a scanning table for the target organ, and an x-ray detector with pure germanium. The minimal detectable dose of iodine in this experiment was 100 ng in a volume of 2 mm3 and a linear relationship was shown between the photon counts of a fluorescent x ray and the concentration of iodine contrast material. A FS x-ray tomographic image was clearly obtained with a phantom.

  14. A library for X-ray-matter interaction cross sections for X-ray fluorescence applications

    Energy Technology Data Exchange (ETDEWEB)

    Brunetti, A. [Istituto di Matematica e Fisica, Universita di Sassari, via Vienna 2, 07100 Sassari (Italy) and INFN, Sezione di Cagliari (Italy)]. E-mail: brunetti@uniss.it; Sanchez del Rio, M. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, 38043 Grenoble Cedex (France); Golosio, B. [INFN, Sezione di Cagliari (Italy); European Synchrotron Radiation Facility, 6 rue Jules Horowitz, 38043 Grenoble Cedex (France); Simionovici, A. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, 38043 Grenoble Cedex (France); Laboratoire de Sciences de la Terre, Ecole Normale Superieure, Lyon, F-69364 (France); Somogyi, A. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, 38043 Grenoble Cedex (France)

    2004-10-08

    Quantitative estimate of elemental composition by spectroscopic and imaging techniques using X-ray fluorescence requires the availability of accurate data of X-ray interaction with matter. Although a wide number of computer codes and data sets are reported in literature, none of them is presented in the form of freely available library functions which can be easily included in software applications for X-ray fluorescence. This work presents a compilation of data sets from different published works and an xraylib interface in the form of callable functions. Although the target applications are on X-ray fluorescence, cross sections of interactions like photoionization, coherent scattering and Compton scattering, as well as form factors and anomalous scattering functions, are also available.

  15. Advanced of X-ray fluorescence logging technique in China

    International Nuclear Information System (INIS)

    Zhou Sichun; Ge Liangquan; Lai Wanchang; Yang Qiang

    2010-01-01

    The paper discuses principle of X-ray fluorescence logging, and introduces advanced of X-ray fluorescence logging technique in China. By 2009, third generation XRF logging instrument has been developed in China, and good logging result has been obtained in Lala copper mine. (authors)

  16. Determination of some elements along the length of pine needles by means of the scanning energy dispersive x-ray fluorescence (EDXRF) method

    International Nuclear Information System (INIS)

    Viksna, A.; Katkevics, J.; Nulle, S.

    1998-01-01

    The scanning energy dispersive X-ray fluorescence (EDXDF) is used to measure the distribution of trace elements along the length of single pine needles. The current set up allows simultaneous determination up to 15 trace elements. The pilot experiments showed that the distribution of some elements varied along length of the pine needle. Concentration variations of trace elements with the needle age and needle position within the foliage crown were also observed. This could be one way of studying the annual physiological cycle of needles. The scanning EDXRF method was compared with graphite furnace atomic absorption spectrometry (GFAAS). (authors)

  17. A coumarin-based "turn-on" fluorescent sensor for the determination of Al3+: single crystal X-ray structure and cell staining properties.

    Science.gov (United States)

    Guha, Subarna; Lohar, Sisir; Sahana, Animesh; Banerjee, Arnab; Safin, Damir A; Babashkina, Maria G; Mitoraj, Mariusz P; Bolte, Michael; Garcia, Yann; Mukhopadhyay, Subhra Kanti; Das, Debasis

    2013-07-28

    An efficient Al(3+) receptor, 6-(2-hydroxybenzylideneamino)-2H-chromen-2-one (HBC), has been synthesized by condensing salicylaldehyde with 6-aminocoumarin. The molecular structure of HBC has been determined by a single crystal X-ray analysis. It was established that in the presence of Al(3+), HBC shows 25 fold enhancement of fluorescence intensity which might be attributed to the chelation-enhanced fluorescence (CHEF) process. HBC binds Al(NO3)3 in a 1 : 1 stoichiometry with a binding constant (K) of 7.9 × 10(4) M(-1). Fe(3+) and Mn(2+) quench the emission intensity of the [HBC + Al(3+)] system to an insignificant extent at a concentration 10 times higher compared to that of Al(3+). HBC is highly efficient in the detection of intracellular Al(3+) under a fluorescence microscope.

  18. Quantitative analysis with energy dispersive X-ray fluorescence analyser

    International Nuclear Information System (INIS)

    Kataria, S.K.; Kapoor, S.S.; Lal, M.; Rao, B.V.N.

    1977-01-01

    Quantitative analysis of samples using radioisotope excited energy dispersive x-ray fluorescence system is described. The complete set-up is built around a locally made Si(Li) detector x-ray spectrometer with an energy resolution of 220 eV at 5.94 KeV. The photopeaks observed in the x-ray fluorescence spectra are fitted with a Gaussian function and the intensities of the characteristic x-ray lines are extracted, which in turn are used for calculating the elemental concentrations. The results for a few typical cases are presented. (author)

  19. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  20. Trace element determination in presolar SiC grains by synchrotron x-ray fluorescence: Commencement of a coordinated multimethod study

    International Nuclear Information System (INIS)

    Knight, K.B.; Sutton, S.R.; Newville, M.; Davis, A.M.; Dauphas, N.; Lewis, R.S.; Amari, S.; Steele, I.M.; Savina, M.R.; Pellin, M.J.

    2008-01-01

    We determined trace element compositions of individual ∼1-3 ?m presolar SiC grains from 6 KJG grains and 26 additionally cleaned KJG grains from the Murchison CM chondrite using nondestructive synchrotron X-ray fluorescence (SXRF). Presolar SiC grains are robust remnants of stellar matter ejected from stars. They survived processing in the early solar system and retain the nucleosynthetic fingerprints of their stellar progenitors. As such, they represent unique physical probes of the interiors of stars. Presolar SiC grains are commonly analyzed by mass spectrometric techniques that determine isotopic compositions and, to some degree, elemental concentrations. These techniques, however, are destructive, and can be subject to matrix effects. Elemental composition data on presolar grains remain scarce and affected by contamination and analytical artifacts. In addition, contamination has plagued isotopic characterization of some elements such as Mo and Ba. We determined trace element compositions of individual ∼1-3 (micro)m presolar SiC grains from the Murchison CM chondrite using nondestructive synchrotron X-ray fluorescence (SXRF). Samples included the KJG fraction, and a second KJG fraction that underwent additional cleaning. As every cleaning step results in some grain loss, one goal of this study was to justify additional cleaning of grains. Six KJG grains and 26 additionally cleaned KJG grains were analyzed, with location and identities of individual grains noted for future correlated isotopic study.

  1. Quantitative x-ray fluorescent analysis using fundamental parameters

    International Nuclear Information System (INIS)

    Sparks, C.J. Jr.

    1976-01-01

    A monochromatic source of x-rays for sample excitation permits the use of pure elemental standards and relatively simple calculations to convert the measured fluorescent intensities to an absolute basis of weight per unit weight of sample. Only the mass absorption coefficients of the sample for the exciting and the fluorescent radiation need be determined. Besides the direct measurement of these absorption coefficients in the sample, other techniques are considered which require fewer sample manipulations and measurements. These fundamental parameters methods permit quantitative analysis without recourse to the time-consuming process of preparing nearly identical standards

  2. Sulfur content measurement in coal by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Cechak, T.; Thinova, L.

    2001-01-01

    X-ray fluorescence, using backscattering, was employed in the determination of sulfur content and ash content measurement in coal. The results of the methods are given to illustrate the differences between the chemical analysis and X-ray fluorescence method.

  3. Dispersive X-ray fluorescence applications in energy in environmental problems diagnostic

    International Nuclear Information System (INIS)

    Odino, R.; Souto, B.; Roca, S.; Campomar, W.

    1994-01-01

    X-ray fluorescence energy was used to detect the grade of contamination due to a Portland cement factory. X-ray fluorescence was used to determine the incidence of a Portland cement plant in the quality of air in its surroundings. Many contaminants (Cu, Pb, Ni, Br) do not come from the Portland cement industry but other industries in the zone

  4. Milli X-Ray Fluorescence Spectrometer

    Data.gov (United States)

    Federal Laboratory Consortium — The Eagle III Micro XRF unit is similar to a traditional XRF unit, with the primary difference being that the X-rays are focused by a polycapillary optic into a spot...

  5. Simple simultaneous determination of soluble and insoluble trace metal components in sea salts by a combined coprecipitation/X-ray fluorescence method

    International Nuclear Information System (INIS)

    Iwatsuki, Masaaki; Ali, Muhammad; Kyotani, Tomohiro; Fukasawa, Tsutomu

    1996-01-01

    An X-ray fluorescence method using the coprecipitation-preconcentration technique has been developed for simple determination of both acid-soluble and insoluble trace metal components, such as manganese, iron, nickel, copper and zinc in sea salts. A salt sample is dissolved in a nitric acid solution, and the residue is filtered off onto a membrane filter. After the pH is adjusted to 7-8, the filtrate is boiled, followed by addition of aluminum carrier, oxine and thionalide solutions. The solution is re-adjusted to pH 9, and kept at 80-85degC for 60 min. The precipitates are filtered off onto another membrane filter. X-Ray fluorescence intensities from two filters loaded with the residue and precipitates are measured and the concentrations of the elements are determined simultaneously using the calibration curves. Detection limits were 0.01 μg g -1 for manganese and copper, 0.04 μg g -1 for nickel and zinc, and 0.05 μg g -1 for iron, regardless of the soluble and the insoluble components. The present method was successfully applied to the analysis of sea salt samples. (author)

  6. A study on the determination of Ca/P molar ratio in calcium-hydroxyapatite by alpha excited x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Iwata, Shiro.

    1979-01-01

    Nondestructive powdery calcium-hydroxyapatite (HAp) target was prepared by electrodeposition method. The powdery HAp was deposited on the copper electrode plate of cathode in the electrodeposition solution such as ethyl alcohol, methyl alcohol, etc. The experiments were carried out as functions of different electrodeposition solution, ethyl alcohol concentration, distance between anode and cathode, electrodeposition time and HAp amount added in bath, and distribution of HAp on the copper electrode plate obtained from each experiment was investigated by alpha excited X-ray fluorescence analysis. Ca/P molar ratio of thin HAp target prepared with this method was determined by alpha excited X-ray fluorescence spectrometry. The nondestructive HAp targets of thickness in the range of 5 mu g/cm 2 to 10 mg/cm 2 were easily prepared with comparatively simple apparatus. The HAp on the copper electrode plate was uniform thickness over 15 x 20 mm copper plate within 5%. The Ca/P molar ratio of HAp was 1.64 +- 0.05, which agreed well with stoichiometric value of 1.67 in HAp within standard deviation. (author)

  7. X-ray fluorescence analysis of praseodymium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Mohile, A.N.

    1976-01-01

    A method for the determination of lanthanum, cerium, neodymium and samarium oxides in praseodymium oxide is described. The sample in the oxalate form is mixed with boric acid binder in the weight ratio of 1:1 and pressed into a pellet. The pellet is irradiated by X-rays from a tungsten tube and fluorescent X-rays are dispersed by a LiF (200) crystal in a Philips semiautomatic X-ray fluorescence spectrometer. The intensity of the characteristic X-rays of the impurity elements is measured by a flow proportional counter at selected 20 angles. The minium determination limit is 0.01% for all impurities. (author)

  8. Absorption correction factor in X-ray fluorescent quantitative analysis

    International Nuclear Information System (INIS)

    Pimjun, S.

    1994-01-01

    An experiment on absorption correction factor in X-ray fluorescent quantitative analysis were carried out. Standard samples were prepared from the mixture of Fe 2 O 3 and tapioca flour at various concentration of Fe 2 O 3 ranging from 5% to 25%. Unknown samples were kaolin containing 3.5% to-50% of Fe 2 O 3 Kaolin samples were diluted with tapioca flour in order to reduce the absorption of FeK α and make them easy to prepare. Pressed samples with 0.150 /cm 2 and 2.76 cm in diameter, were used in the experiment. Absorption correction factor is related to total mass absorption coefficient (χ) which varied with sample composition. In known sample, χ can be calculated by conveniently the formula. However in unknown sample, χ can be determined by Emission-Transmission method. It was found that the relationship between corrected FeK α intensity and contents of Fe 2 O 3 in these samples was linear. This result indicate that this correction factor can be used to adjust the accuracy of X-ray intensity. Therefore, this correction factor is essential in quantitative analysis of elements comprising in any sample by X-ray fluorescent technique

  9. Determination of organic compounds in medicinal plants, commercialized in capsulated forms and 'in natura' by wavelength dispersive X-ray fluorescence spectrometry (WDXRF). Determination of quantitative inorganic profiles

    International Nuclear Information System (INIS)

    Ferreira, Manuel Octavio M.; Sato, Ivone Mulako; Salvador, Vera Lucia R.

    2005-01-01

    X-ray fluorescence technique was used to determine major and trace elements for five Brazilian commercial medicinal plants. The bromobutane (Barbatimao), Ginkgo folium (Ginkgo biloba), Echinodorus macrophyllus (Chapeu de couro), Valeriana officinalis (Valeriana), Cordia salicifolia (Porangaba) samples were collected from three to six different commercial suppliers. The species were collected 'in natura' (leaves, flowers, barks and roots) and capsulated forms. The samples were grinded in liquid N 2 atmosphere and double layer pressed pellet were prepared. The elements Na, Mg, P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, Rb e Sr concentrations were determined by individual calibration curves. The precision and accuracy of method were evaluated by certified reference material, NIST 1547 - Peach Leaves and the Chauvenet, Cochrane, ANOVA and Z-score statistical tests were applied. Each specimen presented a distinct inorganic profile and a great variation in its composition was observed. The inorganic profile will contribute for the elaboration of a quality and security guide to assure the phytotherapics commercialization. Moreover, these profiles could be used as complementary data to active farmaco compounds profiles for specimen's ratification. (author)

  10. Fission products determination in high activity waste solution by wavelength dispersive X-ray fluorescence spectral interference correction by intensity ratio

    International Nuclear Information System (INIS)

    Sato, I.M.

    1988-01-01

    Fission products Se, Rb, Y, Zr, Mo, Ru, Rh, Pd, Te, Cd, Cs, Ba, La, Ce, Pr, Nd, Sm, Eu and Gd were determined in simulated high activity radioactive waste solution by wavelength dispersive X-ray fluorescence spectrometry without chemical separation. Thin layer technique was employed for the sample preparation. For the L spectral lines, the absorption effect was verified by Rasberry-Heinrich, Lucas Tooth-Pyne and Lachance-Trail relations. This effect was quantified and corrected accordingly. The spectral interferences of Kα and/or Lα lines of Y, Zr, Mo, La, Ce, Pr, Nd, Sm, Eu and Gd elements were eliminated by the intensity ratio method. The overlapping of up to three analytical lines was corrected by applying this method. The concentration influence of the interfering element on the intensity ratio values as well the efficiency of the correction method were investigated in order to assure that no systematic or residual error, resulting from the correction, affect the actual fluorescent intensity determination. The results is compared with the data obtained from measurements of free lines of spectral interference and also with those obtained by the linear equation system. Fission products determination presented a precision in the range of 0.1 to 5.0% and an accuracy of up to ± 7.0% the results are compared with those obtained by neutron activation analysis and inductively coupled plasma - atomic emission spectrometry. Leaching data, when radioactive waste is incorporated in cement matrix, were attempted by X-ray fluorescence technique. For two years leaching period, leaching rate and diffusion coefficient data of cesium were determined. The results obtained agree with those obtained by γ-spectromety. (author) [pt

  11. Modern X-ray spectroscopy 3. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi

    2008-01-01

    X-ray fluorescence holography (XFH) provides three dimensional atomic images around specified elements. The XFH uses atoms as a wave source or monitor of interference field within a crystal sample, and therefore it can record both intensity and phase of scattered X-rays. Its current performance makes it possible to apply to ultra thin film, impurity and quasicrystal. In this article, I show the theory including solutions for twin image problem, advanced measuring system, data processing for reconstruction of the atomic images and for obtaining accurate atomic positions, applications using resonant X-ray scattering and X-ray excited optical luminescence, and an example of XFH result on the local structure around copper in silicon steal. (author)

  12. Rare earth aerosol analysis by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Citron, I.M.; Mausner, L.F.

    1982-01-01

    An analytical method for the determination of four lanthanides in air filter samples is described. The method involves simultaneous quantitative determinations of La, Ce, Pr, and Nd at the microgram level by x-ray fluorescence spectrometry without chemical separation of these rare earths and without serious interferences from the dust matrices on the filters. The method has been used successfully to analyze some air filter samples collected at a rare earth processing refinery in Illinois. A description of the development of the method is given as well as the results obtained by using this method on the air filter samples. The reproducibility of the results was generally +-5%

  13. A gravimetric and an X-ray fluorescence method for the determination of rubidium in Rb2U(SO4)3

    International Nuclear Information System (INIS)

    Mudher, K.D.S.; Krishnan, K.; Jayadevan, N.C.

    1993-01-01

    Chemical characterization of rubidium uranium(IV) trisulfate, RB 2 U(SO 4 ) 3 , a new chemical assay standard for uranium requires accurate analysis of rubidium. A gravimetric and an X-ray fluorescence method (XRF) for the determination of rubidium in this compound are described. In the gravimetric method, rubidium is determined as Rb 2 Na[Co(NO 2 ) 6 ].H 2 O without separating uranium with a precision of the order of ±0.5%. In the XRF method, the concentration ratio of rubidium to uranium, C Rb /C U , is determined in the solid samples by the binary ratio method using calibration between intensity ratios (I Rb /I U ) and concentration ratios (C Rb /C U ). (author) 6 refs.; 2 figs.; 3 tabs

  14. Energy dispersive X-Ray fluorescence spectrometric study of ...

    African Journals Online (AJOL)

    Energy dispersive X-Ray fluorescence spectrometric study of compositional differences in trace elements in dried Moringa oleifera leaves grown in two different agro-ecological locations in Ebonyi State, Nigeria.

  15. Determination of indium content of GaAs/(In,Ga)As/(GaAs) core-shell(-shell) nanowires by x-ray diffraction and nano x-ray fluorescence

    Science.gov (United States)

    Al Hassan, Ali; Lewis, R. B.; Küpers, H.; Lin, W.-H.; Bahrami, D.; Krause, T.; Salomon, D.; Tahraoui, A.; Hanke, M.; Geelhaar, L.; Pietsch, U.

    2018-01-01

    We present two complementary approaches to investigate the In content in GaAs/(In,Ga)As/(GaAs) core-shell-(shell) nanowire (NW) heterostructures using synchrotron radiation. The key advantage of our methodology is that NWs are characterized in their as-grown configuration, i.e., perpendicularly standing on a substrate. First, we determine the mean In content of the (In,Ga)As shell by high-resolution x-ray diffraction (XRD) from NW ensembles. In particular, we disentangle the influence of In content and shell thickness on XRD by measuring and analyzing two reflections with diffraction vector parallel and perpendicular to the growth axis, respectively. Second, we study the In distribution within individual NWs by nano x-ray fluorescence. Both the NW (111) basal plane, that is parallel to the surface of the substrate, and the {10-1} sidewall plane were scanned with an incident nanobeam of 50 nm width. We investigate three samples with different nominal In content of the (In,Ga)As shell. In all samples, the average In content of the shell determined by XRD is in good agreement with the nominal value. For a nominal In content of 15%, the In distribution is fairly uniform between all six sidewall facets. In contrast, in NWs with nominally 25% In content, different sidewall facets of the same NW exhibit different In contents. This effect is attributed to shadowing during growth by molecular beam epitaxy. At the same time, along the NW axis the In distribution is still fairly homogeneous. In NWs with 60% nominal In content and no outer GaAs shell, the In content varies significantly both between different sidewall facets and along the NW axis. This fluctuation is explained by the formation of (In,Ga)As mounds that grow simultaneously with a thinner (In,Ga)As shell. The methodology presented here may be applied also to other core-shell NWs with a ternary shell and paves the way to correlating NW structure with functional properties that depend on the as-grown configuration

  16. Multielemental analysis of osseous remains by x-ray fluorescence to determine types of diets from the Cultura Lima (II B.C. - VIII A.C)

    International Nuclear Information System (INIS)

    Montalvo B, A.

    1997-01-01

    The multielemental analysis of 29 human bone samples and sediments from the Lima Culture (III c. BC to IX c. AC) were analyzed by x-ray fluorescence technique with Cd-109 excitation source Si(Li) detector, Canberra associated electronic and PCA-II nucleus multichannel card, in order to determine to determine the diet type of these antique inhabitant. The elements found in bone rests were Ca, Sr, Zn, Mn, Fe, Ni, Cu, Rb, Zn and Pb, and As in one of the clavicles. In sediment samples we obtained a major quantity of elements. According to the Sr an Zn obtained values in osseous rest and the developed regression model, we can conclude that the ancient inhabitants of Lima Culture had an omnivorous feeding with a carnivore tendency due to its geographic location. (author). 35 refs., 9 figs., 10 tabs., 6 ills

  17. Anodic electrode position of cyanometallates as sample preparation for the determination of transition metals from water samples using X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Wundt, K.; Duschner, H.; Starke, K.

    1978-01-01

    The anodic separation of cyanometallates of propanol -2/Water mixtures at high electrical field strengths was developed as new technique for sample preparation. The optimization of the parameters of the system (high voltage applied, current density, separation time and composition of the solution) resulted in quantitative precipitation of the metallates of Fe, Co, Ni, Cu, Zn, Cd and Ag in homogeneous, thin and strong-adhering layer with mass densities of between 1 nmol cm -2 and 1 μmol cm -2 on high-purity aluminium foils. Metals not forming anionic complexes remain in solution with simualtaneous quantitative multielement separation. The described technique is part of a method to determine heavy metal traces in water samples. It comprises the nonspecific sorption on cation exchangers, the elution of the transition metals as cyanometallates, their electrode position on aluminium foil and the determination by X-ray fluorescence analysis. Model experiments illustrate the possible applications of the method. (orig.) [de

  18. Determination of lead associated with airborne particulate matter by flame atomic absorption and wave-length dispersive x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Talebi, S.M.

    1997-01-01

    The lead content of airborne particulate matter was determined by flame atomic absorption spectrometry (FAAS) following digestion with a mixture of nitric acid and hydrogen peroxide and also by wave-length dispersive x-ray fluorescence (WDXRF). The extraction procedure was checked by analyzing a standard reference material of airborne particulate matter (NIST, SRM -1648). It was concluded that lead can quantitatively (98%) be extracted from airborne particulate matter by the leaching process. A five-stage sequential extraction was performed to assess the potential mobility of lead associated with airborne particulate matter. Comparison of the airborne particulate lead measured by WDXRF to that measured by FAAS showed good agreement. The WDXRF method requires no time-consuming sample preparation or use of environmentally unfriendly solvents. The technique is suggested for direct determination of lead in airborne particulate matter in air pollution studies. (author)

  19. System for Gamma an X rays fluorescence spectrometric

    International Nuclear Information System (INIS)

    Alonso Abad, D.; Arista Romeu, E.; Bolanos Perez, L. and others

    1997-01-01

    A system for spectrometry of gamma or fluorescence X rays is presented. It sis composed by a Si(Li) semiconductors detector, a charge sensitive preamplifier, a high voltage power supply, a spectrometric amplifier and a monolithic 1024 channels multichannel analyzers or an IBM compatible 4096 channels add - on- card multichannel analyzer. The system can be configured as a 1024 or 4096 channels gamma or fluorescent X rays spectrometer

  20. Fluorescent intensifying screens: contribution of secondary X-rays

    International Nuclear Information System (INIS)

    Barroso, R.C.; Goncalves, O.D.; Eichler, J.; Lopes, R.T.; Cardoso, S.C.

    1996-01-01

    The counting rate and angular distribution of secondary X-rays produced by fluorescent intensifying screens are studied. A source of 241 Am - gamma radiation of 59.54 keV - is used. Fluorescent intensifying screens reduce the radiation dose in radiology since they produce visible light which increases the efficiency of the film. In addition, secondary X-rays arise due to the photoelectric effect, elastic (Rayleigh) and inelastic (Compton) scattering

  1. Studying atomic-resolution by X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Gao Hongyi; Chen Jianwen; Xie Honglan; Zhu Huafeng; Li Ruxin; Xu Zhizhan

    2005-01-01

    In this work, the results of numerical simulations of X-ray fluorescence holograms and the reconstructed atomic images for Fe single crystal are given. The influences of the recording angles ranges and the polarization effect on the reconstruction of the atomic images are discussed. The process for removing twin images by multiple energy fluorescence holography and expanding the energy range of the incident X-rays to improve the resolution of the reconstructed images is presented

  2. X-ray fluorescent elemental analysis. Ch. 16

    International Nuclear Information System (INIS)

    Baryshev, V.; Kulipanov, G.; Skrinsky, A.

    1991-01-01

    X-ray fluorescence analysis (XFA) is used worldwide to define a quantitative content of the elements as well as to visualize the distribution of elements in different regions (element mapping). Utilization of synchrotron radiation (SR) to excite X-ray fluorescence enables the XFA method to be qualitatively improved. This chapter reviews the experimental work in especially the last decade (author). 71 refs.; 24 figs.; 3 tabs

  3. X-ray fluorescence imaging with synchrotron radiation

    International Nuclear Information System (INIS)

    Rivers, M.L.

    1987-01-01

    The micro-distribution of trace elements is of great interest in fields such as geochemistry, biology and material science. The synchrotron x-ray fluorescence microprobe provides a technique to quantitatively measure trace element compositions at individual points and to construct semiquantitative two dimensional maps of trace element compositions. This paper describes an x-ray fluorescence system used at the National Synchrotron Light Source

  4. X-ray fluorescence cross sections for K and L x rays of the elements

    International Nuclear Information System (INIS)

    Krause, M.O.; Nestor, C.W. Jr.; Sparks, C.J. Jr.; Ricci, E.

    1978-06-01

    X-ray fluorescence cross sections are calculated for the major x rays of the K series 5 less than or equal to Z less than or equal to 101, and the three L series 12 less than or equal to Z less than or equal to 101 in the energy range 1 to 200 keV. This calculation uses Scofield's theoretical partical photoionization cross sections, Krause's evaluation of fluorescence and Coster-Kronig yields, and Scofield's theoretical radiative rates. Values are presented in table and graph format, and an estimate of their accuracy is made. The following x rays are considered: Kα 1 , Kα 1 , 2 , Kβ 1 , Kβ 1 , 3 , Lα 1 , Lα 1 , 2 , Lβ 1 , Lβ 2 , 15 , Lβ 3 , Ll, Lγ 1 , Lγ 4 , and L 1 → L 2 , 3 . For use in x-ray fluorescence analysis, Kα and Lα fluorescence cross sections are presented at specific energies: TiK identical with 4.55 keV, CrK identical with 5.46 keV, CoK identical with 7.00 keV, CuK identical with 8.13 keV, MoKα identical with 17.44 keV, AgK identical with 22.5 keV, DyK identical with 47.0 keV, and 241 Am identical with 59.54 keV. Supplementary material includes fluorescence and Coster--Kronig yields, fractional radiative rates, fractional fluorescence yields, total L-shell fluorescence cross sections, fluorescence and Coster-Kronig yields in condensed matter, effective fluorescence yields, average L-shell fluorescence yield, L-subshell photoionization cross section ratios, and conversion factors from barns per atom to square centimeters per gram

  5. Studies of some alloys using x-ray fluorescence

    International Nuclear Information System (INIS)

    Elmahi, Elamin Musaid

    1997-01-01

    In this project an attempt has been made for the study of alloys commonly used using x-ray fluorescence ( XRF ) technique. The alloys selected for the study included gold jewellery, steels, brasses and coins. The XRF method proved to be simple, fast, non-destructive and reliable as compared to chemical methods. The results showed that most of the gold jewellery used in this country have carat value of 18 and 21. Also most coins used in different countries are alloys of Cu and Ni. A simple spark method was used for the determination of C in steels, since C is not possible to analyze by XRF. ( Author )

  6. X-ray fluorescence in IAEA Member States: Spain

    International Nuclear Information System (INIS)

    Roldan, C.; Ferrero, J.L.

    2004-01-01

    Full text: Instrumental facilities of the ICMUV include: a Total-reflection X-Ray Fluorescence (TXRF), laboratory and portable Energy Dispersive X-Ray Fluorescence (EDXRF) spectrometers. These equipments are employed in the field of the art and archaeometry. Current projects are: EDXRF analysis of blue pigments used in Valencian ceramics. EDXRF analyses of cobalt-blue pigments were made on 73 pieces of Valencian ceramics from the beginning of the 14th century up to 20th century. These ceramic samples have the pigment decoration applied together with a tin opacified lead glaze cover on the clay body. The comparison between EDXRF spectra from coloured and non-coloured areas provides information about the pigment composition. The following elements: Mn, Fe, Co, Ni, Cu, Zn and As are identified as characteristics of the blue pigments. Different association of these elements as well as correlation with the chronology of the samples were found. These results can be used for identifying the different types of cobalt ores employed in the manufacture of the blue pigments to study their provenance. Non-destructive analysis of paper supports used in prints: In paper based works of art it is not possible to separate the support from the work of the author. Then, the maximum knowledge of the support in this kind of works is desirable. In this work, Energy Dispersive X-Ray Fluorescence (EDXRF) was used to determine the elemental composition of a set of European and Oriental papers from the 20th century and an Arabian paper from the 14th century. These papers were manufactured with different production techniques and used as support for writing, drawing and printing. Normalised fluorescence yields of the elements to the weight of the paper show that there are some correlations between its elemental composition and the type of paper, provenance and use. Therefore, the Energy Dispersive X-Ray Fluorescence (EDXRF) technique could be used for a better characterization and

  7. Determination of bromine in selected polymer materials by a wavelength-dispersive X-ray fluorescence spectrometric method - Critical thickness problem and solutions

    Science.gov (United States)

    Gorewoda, Tadeusz; Mzyk, Zofia; Anyszkiewicz, Jacek; Charasińska, Jadwiga

    2015-04-01

    The purpose of this study was to develop an accurate method for the determination of bromine in polymer materials using X-ray fluorescence spectrometry when the thickness of the sample is less than the bromine critical thickness (tc) value. This is particularly important for analyzing compliance with the Restriction of Hazardous Substances Directive. Mathematically and experimentally estimated tc values in polyethylene and cellulose matrixes were up to several millimeters. Four methods were developed to obtain an accurate result. These methods include the addition of an element with a high mass absorption coefficient, the measurement of the total bromine contained in a defined volume of the sample, the exploitation of tube-Rayleigh line intensities and using the Br-Lβ line.

  8. Determination of metals by total reflection X-ray fluorescence and evaluation of toxicity of a river impacted by coal mining in the south of Brazil.

    Science.gov (United States)

    Lattuada, R M; Menezes, C T B; Pavei, P T; Peralba, M C R; Dos Santos, J H Z

    2009-04-30

    Metal (Fe, Mn, Zn, Ni, Cd, and Pb) concentrations in the region of Criciuma (Brazil), a region impacted by coal mining, were determined in water and sediments using total reflection X-ray fluorescence (TXRF) spectroscopy. Samples were collected from the Mãe Luzia River (south Brazil) at five different stations, from the source down to the river mouth (Ararangua estuary). Water and sediment toxicity were also evaluated using bioassays with Daphnia magna as the bioindicator. The metal present in the highest concentrations both in water (1.3-11 mg L(-1)) and in sediments (34-142 mg L(-1)) was iron. Results suggest an influence of coal mining on the aquatic receptors, showing a clear relationship between metal content (mostly Fe) and ecotoxicity.

  9. Optimization of methodology by X-ray fluorescence for the metals determination in aquatic plants of the high course of the Lerma river

    International Nuclear Information System (INIS)

    Albino P, E.

    2015-01-01

    The high course of the Lerma river has a pollution problem in its hydrological system due to discharges of urban wastewater and industrial areas; the pollutants that affect the hydrological system are metals, which are absorbed by living organisms and probably incorporated into the food chain. For this reason in this work the technique of X-ray fluorescence total reflection was applied in six species of aquatic plants that grow in the high course of the Lerma river: Arroyo Mezapa (Eichhornia crassipes, Juncus efusus, Hydrocotyle, Schoenoplectus validus) Ameyalco river (Lemna gibba) and Atarasquillo river (Berula erecta) in order to evaluate the metals concentration (Cr, Mn, Fe, Ni, Cu, Zn and Pb) as well as the translocation factor and bioaccumulation factor for each aquatic species. According to the results, was observed that the highest concentration of metals is located in the deeper parts; metals which present a significant concentration are Mn and Fe in the six species of aquatic plants. According to the translocation factor the species having a higher translocation of metals are: Juncus efusus in Mn (1.19 mg/L) and Zn (1.31 mg/L), Hydrocotyle (1.14 mg/L), the species Eichhornia crassipes not show translocation. For bioaccumulation factor, was observed that the most bioaccumulation of metals is found in the soluble fraction of the six species of aquatic plants, especially Fe followed of Cu and Zn. Also was considered that the Berula erecta plant had a higher bioaccumulation of metals such as Cr, Mn, Fe, Cu and Zn so it can be considered as a hyper-accumulating species of these elements. With the results can be considered that the technique of X-ray fluorescence total reflection is 95% reliable to determine the concentration of metals within the structures of the aquatic plants used for this study. (Author)

  10. The Mapping X-ray Fluorescence Spectrometer (MapX)

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  11. X-ray Free Electron Laser Determination of Crystal Structures of Dark and Light States of a Reversibly Photoswitching Fluorescent Protein at Room Temperature

    Directory of Open Access Journals (Sweden)

    Christopher D. M. Hutchison

    2017-09-01

    Full Text Available The photochromic fluorescent protein Skylan-NS (Nonlinear Structured illumination variant mEos3.1H62L is a reversibly photoswitchable fluorescent protein which has an unilluminated/ground state with an anionic and cis chromophore conformation and high fluorescence quantum yield. Photo-conversion with illumination at 515 nm generates a meta-stable intermediate with neutral trans-chromophore structure that has a 4 h lifetime. We present X-ray crystal structures of the cis (on state at 1.9 Angstrom resolution and the trans (off state at a limiting resolution of 1.55 Angstrom from serial femtosecond crystallography experiments conducted at SPring-8 Angstrom Compact Free Electron Laser (SACLA at 7.0 keV and 10.5 keV, and at Linac Coherent Light Source (LCLS at 9.5 keV. We present a comparison of the data reduction and structure determination statistics for the two facilities which differ in flux, beam characteristics and detector technologies. Furthermore, a comparison of droplet on demand, grease injection and Gas Dynamic Virtual Nozzle (GDVN injection shows no significant differences in limiting resolution. The photoconversion of the on- to the off-state includes both internal and surface exposed protein structural changes, occurring in regions that lack crystal contacts in the orthorhombic crystal form.

  12. Total reflection x-ray fluorescence - an approach to nanoanalysis

    International Nuclear Information System (INIS)

    Klockenkaemper, R.

    2000-01-01

    X-ray fluorescence analysis (XRFA) is a powerful tool used for industrial production, geological prospecting and for environmental control. However, the method suffers from a lack of sensitivity so that analyses are restricted to microanalytical investigations. That means: the sample amount needed for analysis is above some 10 micrograms, concentrations to be determined have to be on the μg/ml level, and thin layers to be characterized must be of micrometer thickness. In contrast to conventional XRFA, total-reflection X-ray fluorescence (TXRF) is extremely sensitive and even allows nano-analytical investigations. Three different ways can be taken: (i) use of minute sample amounts of only 10 nano-grams, (ii) determination of extreme traces below ng/ml and (iii) surface analysis and depth profiling of shallow layers with nano-meter thickness. In this lecture, the basic physical phenomena of total reflection and standing waves are outlined. The experimental equipment for TXRF is sketched out and commercially available instruments of different manufacturers are compared. Furthermore, examples are given for the three kinds of nano-analytical applications: ultra-micro, analysis, ultra trace analysis and mono- and thin-layer analysis. (author)

  13. Total-reflection x-ray fluorescence with a brillant undulator x-ray source

    International Nuclear Information System (INIS)

    Sakurai, K.; Eba, H.; Numako, C.; Suzuki, M.; Inoue, K.; Yagi, N.

    2000-01-01

    Total-reflection x-ray fluorescence (TXRF) is a highly sensitive technique for analyzing trace elements, because of the very low background from the sample support. Use of third-generation synchrotron x-ray source could further enhance the detection power. However, while such high sensitivity permits the detection of signals from trace elements of interest, it also means that one can observe weak parasitic x-rays as well. If the sample surface becomes even slightly contaminated, owing to air particulates near the beamline, x-ray fluorescence lines of iron, zinc, copper, nickel, chromium, and titanium can be observed even for a blank sample. Another critical problem is the low-energy-side tail of the scattering x-rays, which ultimately restricts the detection capability of the technique using a TXRF spectrometer based on a Si(Li) detector. The present paper describes our experiments with brilliant undulator x-ray beams at BL39XU and BL40XU, at the SPring-8, Harima, Japan. The emphasis is on the development of instruments to analyze a droplet of 0.1 μl containing trace elements of ppb level. Although the beamline is not a clean room, we have employed equipment for preparing a clean sample and also for avoiding contamination during transferring the sample into the spectrometer. We will report on the successful detection of the peak from 0.8 ppb selenium in a droplet (absolute amount 80 fg). We will also present the results of recent experiments obtained from a Johansson spectrometer rather than a Si(Li) detector. (author)

  14. X-Ray Fluorescence Spectrometry. II Determination of Uranium in ores; Espectrometria de fluorescencia de Rayos X. II-Aplicacion a la determinacion de uranio en minerales

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez Polonio, J; Crus Castillo, F. de la; Fernandez Cellini, R

    1961-07-01

    A method of analysis of uranium in ores by X-ray spectrometry was developed, using the internal standard technique. Strontium was found to be the most suitable internal standard for general use. A Norelco Philips X-ray fluorescent spectrometer was used in this work, equipped with a lithium fluoride crystal acting as a diffraction grating analyzer. The intensity of the uranium-L {alpha}{sub 1} spectral line is calculated and related to corresponding strontium-K{sub {alpha}} spectral line, both detected with a Scintillation Counter. (Author) 31 refs.

  15. Certification of reference materials by energy-dispersive x-ray fluorescence spectrometry?

    DEFF Research Database (Denmark)

    Christensen, Leif Højslet; Heydorn, Kaj

    1985-01-01

    This paper studies the precision and accuracy that can be achieved using energy-dispersive x-ray fluorescence spectrometry for the determination of total sulphur content in BCR 38 Fly Ash issued by the European Community Bureau of Reference.......This paper studies the precision and accuracy that can be achieved using energy-dispersive x-ray fluorescence spectrometry for the determination of total sulphur content in BCR 38 Fly Ash issued by the European Community Bureau of Reference....

  16. Use of X-ray fluorescence energy dispersive technique in the lead determination and other metals in excrements of otters (Lontra longicaudis)

    International Nuclear Information System (INIS)

    Moraes, Liz Mary B.; Silva, Richard M.C.; Nascimento Filho, Virgilio F.; Ferreira, Carla Josef; Adriano, Leonardo R.; Ferreira, Jose Roberto

    2005-01-01

    This work had for objective to evaluate the contamination for Pb and other metals (Ti, Mn, Fe, Ni, Cu and Zn) in excrement samples of a neotropical otter population specie, found in river Betari, Alto Vale do Ribeira basin, Southeast Sao Paulo State. This river is a tributary of the Ribeira de Iguape river and part of its passage meets inside of the Parque Estadual Turistico do Alto Ribeira, one of the most conserved area of Brazilian Atlantic Forest. As the diet of these animals is based in fishes, it is an environmental interest in the determination of Pb in its excrements, since that is accumulating on the tropical chain path and in this region (in the decade of 1970) had the implanted a Pb extraction from galena mining. The analysis of the samples requires frequently the chemical digestion, with the disadvantages of being weak and expense. Aiming at to eliminate these disadvantages, the objective of the work was to use the X-ray fluorescence energy dispersive technique (EDXRF), for demanding a minimum preparation of the sample. Six excrement samples had been frozen, lyophilized and cryogenically milled, and after analyzed as pellet form, using a X-ray tube (target Mo, Zr filter, 25 kV/10 mA) and Si(Li) semiconductor spectrometer. The concentration was varied from 5.0 to 15.4 μg g -1 and it was possible also quantified other metals, showing maximum concentrations: Ti - 308, Mn - 38, Fe - 1131, Ni - 44, Cu . 2.8 and Zn . 92.4 μg g -1 . (author)

  17. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy; Determinacion de plomo en esmaltado de barro por Fluorescencia de rayos X en reflexion total y Microscopia Electronica de Barrido

    Energy Technology Data Exchange (ETDEWEB)

    Zarazua O, G.; Carapia M, L. [Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  18. Application of multivariate calibration for simultaneous determination of major and minor constituents in U3Si2 by X-ray fluorescence

    International Nuclear Information System (INIS)

    Scapin, Marcos A.; Silva, Clayton P.; Cotrim, Marycel E.B.; Pires, Maria Aparecida F.

    2013-01-01

    The aim of this work is to establish and validate a methodology for a nondestructive quantitative chemical analysis method for simultaneous determination of the major constituents (U total and Si) and impurities (B, Mg, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, Cd,etc.) present in U 3 Si 2 . The method must also meet the needs of nuclear reactors for the nuclear fuel qualification type,MTR, with low cost and analysis time, while also minimizing waste generation. For this purpose, an X-ray fluorescence technique will be applied. The technique is nondestructive,aside from sample preparation procedures that do not require previous chemical treatments (dissolving, digesting), and allows for fast chemical analysis. The fundamental parameters (FP) method was applied to corrections for spectral and matrix effects. The calibration model was obtained via principal component analysis using orthogonal decomposition by the singular value decomposition method (SVD) in U 3 O 8 and U 3 Si 2 samples. The results were compared by means of statistical tests in accordance with ISO 17025 on CRMs of U 3 O 8 from New Brunswick Laboratory (NBL) and 16 U 3 Si 2 samples provided by CCN of IPEN/CNEN-SP. Multivariate calibration is a promising method for determination of major and minor constituents inU 3 Si 2 and U 3 O 8 nuclear fuel, because the precision and accuracy are statistically equivalent to volumetric analysis (U total determination), gravimetric analysis (Si determination), and ICP-OES methods (impurities determination). (author)

  19. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    International Nuclear Information System (INIS)

    Dhara, Sangita; Misra, N.L.; Maind, S.D.; Kumar, Sanjukta A.; Chattopadhyay, N.; Aggarwal, S.K.

    2010-01-01

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 μL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO 3 /HClO 4 , mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1σ) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  20. Forensic application of total reflection X-ray fluorescence spectrometry for elemental characterization of ink samples

    Energy Technology Data Exchange (ETDEWEB)

    Dhara, Sangita [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Misra, N.L., E-mail: nlmisra@barc.gov.i [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Maind, S.D. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Kumar, Sanjukta A. [Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Chattopadhyay, N. [NAA Unit of Central Forensic Science Laboratory Hyderabad at Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India); Aggarwal, S.K. [Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085 (India)

    2010-02-15

    The possibility of applying Total Reflection X-ray Fluorescence for qualitative and quantitative differentiation of documents printed with rare earth tagged and untagged inks has been explored in this paper. For qualitative differentiation, a very small amount of ink was loosened from the printed documents by smoothly rubbing with a new clean blade without destroying the manuscript. 50 muL of Milli-Q water was put on this loose powder, on the manuscript, and was agitated by sucking and releasing the suspension two to three times with the help of a micropipette. The resultant dispersion was deposited on quartz sample support for Total Reflection X-ray Fluorescence measurements. The Total Reflection X-ray Fluorescence spectrum of tagged and untagged inks could be clearly differentiated. In order to see the applicability of Total Reflection X-ray Fluorescence for quantitative determinations of rare earths and also to countercheck such determinations in ink samples, the amounts of rare earth in painted papers with single rare earth tagged inks were determined by digesting the painted paper in HNO{sub 3}/HClO{sub 4}, mixing this solution with the internal standard and recording their Total Reflection X-ray Fluorescence spectra after calibration of the instrument. The results thus obtained were compared with those obtained by Inductively Coupled Plasma Mass Spectrometry and were found in good agreement. The average precision of the Total Reflection X-ray Fluorescence determinations was 5.5% (1sigma) and the average deviation of Total Reflection X-ray Fluorescence determined values with that of Inductively Coupled Plasma Mass Spectrometry was 7.3%. These studies have shown that Total Reflection X-ray Fluorescence offers a promising and potential application in forensic work of this nature.

  1. Characterization of a pulsed x-ray source for fluorescent lifetime measurements

    International Nuclear Information System (INIS)

    Blankespoor, S.C.; Derenzo, S.E.; Moses, W.W.; Rossington, C.S.; Ito, M.; Oba, K.

    1994-01-01

    To search for new, fast, inorganic scintillators, the authors have developed a bench-top pulsed x-ray source for determining fluorescent lifetimes and wavelengths of compounds in crystal or powdered form. This source uses a light-excited x-ray tube which produces x-rays when light from a laser diode strikes its photocathode. The x-ray tube has a tungsten anode, a beryllium exit window, a 30 kV maximum tube bias, and a 50 μA maximum average cathode current. The laser produces 3 x 10 7 photons at 650 nm per ∼100 ps pulse, with up to 10 7 pulses/sec. The time spread for the laser diode, x-ray tube, and a microchannel plate photomultiplier tube is less than 120 ps fwhm. The mean x-ray energy at tube biases of 20, 25, and 30 kV is 9.4, 10.3, and 11.1 keV, respectively. The authors measured 140, 230, and 330 x-ray photons per laser diode pulse per steradian, at tube biases of 20, 25, and 30 kV, respectively. Background x-rays due to dark current occur at a rate of 1 x 10 6 and 3 x 10 6 photons/sec/steradian at biases of 25 and 30 kV, respectively. Data characterizing the x-ray output with an aluminum filter in the x-ray beam are also presented

  2. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Czech Academy of Sciences Publication Activity Database

    Bártová, H.; Kučera, Jan; Musílek, L.; Trojek, T.

    2014-01-01

    Roč. 104, NOV (2014), s. 393-397 ISSN 0969-806X. [1st International Conference on Dosimetry and its Applications (ICDA). Prague, 23.6.2013-28.6.2013] R&D Projects: GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : Alpha coutning * neutron activation analysis * X-ray fluorescence * thermoluminescence dating * dose rate Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.380, year: 2014

  3. Device for the determination of concentrations of fissile and/or fertile materials by means of x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Von Baeckmann, A.; Neuber, J.

    1975-01-01

    In analyzing fissile and/or fertile materials in the thorium, uranium, neptunium, plutonium, americium and curium group, time and accuracy are significant factors. An automated system for rapidly analyzing these materials includes: sample preparation device in which aliquots of sample are weighed and mixed with known amounts of solution; x-ray fluorescence spectrometer; and, a central control system for controlling the operation and analyzing the data. (auth)

  4. Uranium concentrate analysis by X-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Diaz-Guerra, J.P.; Bayon, A.; Roca, R.

    1978-01-01

    The determination of As, Ca, Fe, Mo, P, S, Si. Th, V and U in uranium concentrates by X-ray fluorescence spectroscopy has been studied. As and U are determined in nitric solutions and for the rest of elements analysis is performed by a bead fusion technique using Li 2 B 4 O 7 and Li 2 CO 3 as fluxes. Although the uranium matrix minimizes the absorption and enhancement effects, because of the content variations of this element it is advisable to operate at a constant level of U 3 O 8 . Despite the high matrix absorption and the large dilution of the samples, sensitivity and speed are found to be satisfactory as the result of the use of a high sensitivity automatic spectrometer. The spectral interferences of Mo on S and P, and of Pb on As have been particularly considered. (author) [es

  5. Compositional analysis of steels by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Kutty, K.V.G.; Rajagopalan, S.; Ananthakrishnan, S.K.; Asuvatharaman, R.

    1988-01-01

    The x-ray fluorescence spectrometric method of determining Ni, Cr, Mn, Mo, T i, Si and Co in austenitic, ferritic, titanium-stabilised and low alloy steels is described. Samples in the bulk solid form (25-50 mm diameter and upto 50 mm height) or very small samples having a flat surface at least 5 mm in diameter are analysed as received after a brief surface treatment. The complex matrix effects affecting the determination of the various elements are discussed. The direct calibration method as well as the mathematical method of empirical coefficients of overcoming the matrix effects is described. The precision and accuracy of the analyses are discussed. (author). 10 refs

  6. Simultaneous analysis of gaseous and particulate sulphur in the atmosphere by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Matsuda, Yatsuka; Mamuro, Tetsuo

    1975-01-01

    An analytical technique for the simultaneous measurements of the atmospheric concentrations of SO 2 gas and sulphur absorbed by aerosol particles has been developed. Aerosol particles are collected on membrane filter and at the same time SO 2 gas is captured on alkali impregnated filter. The sulphur content in each filter is measured by an energy dispersive X -ray fluorescence spectrometer consisting of a Si(Li) semiconductor detector connected to a multi-channel pulse height analyzer and an excitation source of 55 Fe. Two methods are acceptable for the determination of the sulphur content in impregnated filter by X-ray fluorescence analysis. In the first method X-ray fluorescence analysis is made after the collected sulphur gas diffused and distributed uniformly enough throughout the filter, and in the second method X-ray fluorescence analysis gas to be finished before the diffusion of the collected sulphur becomes appreciable. (author)

  7. Rapid determination of trace phosphorus, sulfur, chlorine, bromine and iodine by energy dispersive X-ray fluorescence analysis with monochromatic excitations

    International Nuclear Information System (INIS)

    Wakisaka, Tatsushi; Morita, Naoki; Hirabayashi, Tadashi; Nakahara, Taketoshi

    1998-01-01

    A useful and rapid procedure is described for the determination of trace phosphorus, sulfur, chlorine, bromine, and iodine by means of an energy dispersive X-ray fluorescence spectrometer (EDXRF) with monochromatic excitations. Using monochromatic excitations, the detection limits for phosphorus, sulfur, chlorine (Cr-Kα, 5.41 keV), bromine (Mo-Kα, 17.44 keV), and iodine (W-continuum, 40 keV) were found to be 4.6, 1.7, 0.7, 0.09 and 0.5 μg g -1 , respectively. The relative standard deviations in five replicate measurements were 0.9-1.3%. The proposed method was applied to the direct determination of sulfur in the NIST Residual Fuel Oil, and others. The results obtained by the proposed method were in good agreement with the certified values. Bromine in a seawater sample, as well as iodine and bromine in a brine sample were determined by the proposed method. The obtained results were in good agreement with those obtained by ion chromatography. (author)

  8. [Method of fused sample preparation after nitrify-determination of primary and minor elements in manganese ore by X-ray fluorescence spectrometry].

    Science.gov (United States)

    Song, Yi; Guo, Fen; Gu, Song-hai

    2007-02-01

    Eight components, i. e. Mn, SiO2, Fe, P, Al2O3, CaO, MgO and S, in manganese ore were determined by X-ray fluorescence spectrometer. Because manganese ore sample releases a lot of air bubbles during fusion which effect accuracy and reproducibility of determination, nitric acid was added to the sample to destroy organic matter before fusion by the mixture flux at 1000 degrees C. This method solved the problem that the flux splashed during fusion because organic matter volatilized brought out a lot of air bubbles, eliminated particle size effects and mineral effect, while solved the problem of volatilization of sulfur during fusion. The experiments for the selection of the sample preparation conditions, i. e. fusion flux, fusion time and volume of HNO3, were carried out. The matrix effects on absorption and enhancement were corrected by variable theoretical alpha coefficient to expand the range of determination. Moreover, the precision and accuracy experiments were performed. In comparison with chemical analysis method, the quantitative analytical results for each component are satisfactory. The method has proven rapid, precise and simple.

  9. Design and construction of a detection system for the determination of lead in blood using x-ray fluorescence analysis. Progress report, August 1, 1974--July 31, 1975

    International Nuclear Information System (INIS)

    Laurer, G.R.; Kneip, T.J.

    1975-01-01

    Intercomparison difficulties between x-ray fluorescence (XRF) and atomic absorption (AA) measurements of blood lead were due to weight variations in the samples which are correlated to the hemoglobin content. Correction factors were developed to account for changes in background and sensitivity due to weight and hence hemoglobin content variations. Good agreement was achieved in comparisons of XRF and AA determinations on baboon blood, and a preliminary intercomparison with the New York City Health Department demonstrated that the corrected XRF values are accurate for children's blood. The XRF system can accurately determine blood lead concentrations in the range of 0.1 to 3.0 ppM. The difference in the content of zinc in the urine of two individuals undergoing chelation therapy was determined, using XRF analysis, on samples taken before and after treatment. The ratio of the count rate under the Zn K/sub alpha/ peak for one of these persons after treatment was 250 : 1, compared to before chelation. (U.S.)

  10. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    Science.gov (United States)

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  11. X-ray fluorescence and the study of microcirculation

    International Nuclear Information System (INIS)

    Muthuvelu, P.; Hugtenburg, R.P.; Bradley, D.A.; Winlove, C.P.

    2004-01-01

    The feasibility of using K-shell X-ray fluorescence (XRF) technique for study of subchondral bone microcirculation in ex vivo samples is examined. Studies have been carried out at the Daresbury Laboratory Synchrotron Radiation Source (SRS) ultra-dilute extended X-ray absorption fine structure beamline. Initial investigations were made on fine-bore capillaries with diameters of either 500 or 200 μm, attenuated by up to 2 mm of Perspex and containing dilute iodine-based contrast media. This allowed comparison to be made with the capabilities of angiographic imaging systems, also allowing definition of suitable XRF set-up parameters for subsequent microcirculation studies. Measurements were obtained in 30 s run times, for concentrations of iodine (K ab 33.164 keV) down to 2 /(ml saline). Intensities were linear up to 3.7 mg/ml, self-absorption becoming significant for concentrations beyond this. To determine detection limits, preliminary studies of subchondral bone microcirculation were made on bone sections which were known to be poorly infused with silver-coated (K ab 25.517 keV) 30 μm diameter microspheres. For a 2 mm slice of bone, the presence of small numbers of silver-coated microspheres were detected in the first 2 mm layer from the surface, at a level equivalent to ∼1 ppm of silver solution

  12. Method for determination of Fe, Co, Ni, Cu, Zn and Pb in sea water using X-ray fluorescence analysis, after concentration step of these elements by coprecipitation with APDC

    International Nuclear Information System (INIS)

    Lam, P.; Estevez Alvarez, J.R.; Pupo Gonzalez, I.; Ramirez, M.; Rivera, N.

    1998-01-01

    In this work an analytical procedure has been applied to the to the determination of Fe, Co, Ni, Cu, Zn y Pb in seawater, that includes a coprecipitation step applied of these metals with APDC. The final analysis is carried out by X-Ray Fluorescence Analysis thin layer absolute method

  13. In vivo x-ray fluorescence of lead and other toxic trace elements

    International Nuclear Information System (INIS)

    Chettle, D.R.

    1995-01-01

    The first in vivo x-ray fluorescence measurements of lead in bone used y-rays from a 57 Co source to excite Pb K x-rays. Later systems used γ-rays from 109 Cd to excite Pb K x-rays or polarized x-rays to excite Ph L x-rays. All three approaches involve an extremely low effective dose to the subject. Of the two K x-ray techniques, 109 Cd is more precise and more flexible in choice of measurement site. Pb L x-ray fluorescence (L-XRF) effectively samples lead at bone surfaces, whereas Ph K x-ray fluorescence (K-XRF) samples through the bulk of a bone. Both the polarized L-XRF and 109 Cd K-XRF achieve similar precision. Renal mercury has recently been determined using a polarized x-ray source, Both renal and hepatic cadmium can be measured using polarized x-rays in conjunction with a Si(Li) detector. Platinum and gold have been measured both by radioisotopic source excitation and by using polarized x-rays, but the latter is to be preferred. Applications of Pb K-XRF have shown that measured bone lead relates strongly to cumulative lead exposure. Secondly, biological half lives of lead in different bone types have been estimated from limited longitudinal data sets and from some cross sectional surveys. Thirdly, the effect of bone lead as an endogenous source of lead has been demonstrated and it has been shown that a majority of circulating blood lead can be mobilized from bone, rather than deriving from new exposure, in some retired lead workers. 35 refs., 5 tabs

  14. Preliminary Study to Test the Feasibility of Sex Identification of Human (Homo sapiens) Bones Based on Differences in Elemental Profiles Determined by Handheld X-ray Fluorescence.

    Science.gov (United States)

    Nganvongpanit, Korakot; Buddhachat, Kittisak; Brown, Janine L; Klinhom, Sarisa; Pitakarnnop, Tanita; Mahakkanukrauh, Pasuk

    2016-09-01

    Sex assignment of human remains is a crucial step in forensic anthropological studies. The aim of this study was to examine elemental differences between male and female bones using X-ray fluorescence (XRF) and determine if elemental profiling could be used for sex discrimination. Cranium, humerus, and os coxae of 60 skeletons (30 male, 30 female) from the Chiang Mai University Skeletal Collection were scanned by XRF and differences in elemental profiles between male and female bones determined using discriminant analysis. In the cranium, three elements (S, Ca, Pb) were significantly higher in males and five elements (Si, Mn, Fe, Zn, Ag) plus light elements (atomic number lower than 12) were higher in females. In humerus and os coxae, nine elements were significantly higher in male and one element was higher in female samples. The accuracy rate for sex estimation was 60, 63, and 61 % for cranium, humerus, and os coxae, respectively, and 67 % when data for all three bones were combined. We conclude that there are sex differences in bone elemental profiles; however, the accuracy of XRF analyses for discriminating between male and female samples was low compared to standard morphometric and molecular methods. XRF could be used on small samples that cannot be sexed by traditional morphological methods, but more work is needed to increase the power of this technique for gender assignment.

  15. Evaluation of field-portable X-ray fluorescence spectrometry for the determination of lead contamination on small-arms firing ranges

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.F.; Taylor, J.D.; Bass, D.A.; Zellmer, D. [Argonne National Lab., IL (United States); Rieck, M. [U.S. Army, Grafenwoehr Training Area (Germany)

    1995-02-01

    Field analytical methods for the characterization of lead contamination in soil are being developed. In this study, the usefulness of a commercially available, field-portable energy-dispersive X-ray fluorescence spectrometer (XRF) is evaluated for determining the extent of lead contamination in soils on small-arms firing ranges at a military installation. This field screening technique provides significant time and cost savings for the study of sites with lead-contaminated soil. Data obtained with the XRF unit in the field are compared with data obtained from soil samples analyzed in an analytical laboratory by inductively coupled plasma atomic emission spectroscopy. Results indicate that the field-portable XRF unit evaluated in this study provides data that are useful in determining the extent and relative magnitude of lead contamination. For the commercial unit used in this study, improvements in the spectral resolution and in the limit of detection would be required to make the unit more than just a screening tool.

  16. Applicability of X-ray fluorescence spectroscopy as method to determine thickness and composition of stacks of metal thin films: A comparison with imaging and profilometry

    International Nuclear Information System (INIS)

    Vrielink, J.A.M.; Tiggelaar, R.M.; Gardeniers, J.G.E.; Lefferts, L.

    2012-01-01

    In this work the applicability of X-ray fluorescence spectroscopy (XRF) for fast, accurate and non-destructive determination of the thickness of a variety of single-layer and multi-layer metal thin films deposited on glass and silicon is investigated. Data obtained with XRF is compared with information from profilometry and images from scanning electron microscopy (SEM). Whereas thickness determinations based on profilometry and cross-sectional SEM-imaging have restrictions with respect to thickness of metal stacks or hardness of the metals, XRF has no such limitations. Moreover, XRF can discriminate between sublayers in a multi-layer film, and can also be utilized for compositional analysis and density estimations. Good agreement between thickness data obtained with XRF, profilometry and SEM-images is found, under the justifiable assumption that the density of sputter-deposited and evaporated thin films is ca. 5% below that of bulk metals. Similar XRF-results are found for non-patterned areas (64 mm 2 metal) as well as lithographically patterned areas containing a series of small metal lines (total metal surface ca. 8 mm 2 ). As a consequence, it is concluded that XRF is a versatile technique for analysis, verification, control or evaluation of the thickness, density or (elemental) composition of thin metal film line-patterns, during their fabrication as well as prior or post to applications.

  17. Determination of inorganic nutrients in wheat flour by laser-induced breakdown spectroscopy and energy dispersive X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Peruchi, Lidiane Cristina; Nunes, Lidiane Cristina; Gustinelli Arantes de Carvalho, Gabriel; Guerra, Marcelo Braga Bueno; Almeida, Eduardo de; Rufini, Iolanda Aparecida [NAPTISA Research Support Center “Technology and Innovation for a Sustainable Agriculture”, Center for Nuclear Energy in Agriculture, University of São Paulo, Av. Centenário 303, 13416-000, Piracicaba SP (Brazil); Santos, Dário [Federal University of São Paulo, R. Prof. Artur Riedel 275, 09972-270, Diadema SP (Brazil); Krug, Francisco José, E-mail: fjkrug@cena.usp.br [NAPTISA Research Support Center “Technology and Innovation for a Sustainable Agriculture”, Center for Nuclear Energy in Agriculture, University of São Paulo, Av. Centenário 303, 13416-000, Piracicaba SP (Brazil)

    2014-10-01

    Laser-induced breakdown spectroscopy (LIBS) and energy dispersive X-ray fluorescence spectrometry (EDXRF) were evaluated for the determination of P, K, Ca, Mg, S, Fe, Cu, Mn and Zn in pressed pellets of wheat flours. EDXRF and LIBS calibration models were built with analytes mass fractions determined by inductively coupled plasma optical emission spectrometry after microwave-assisted acid digestion in a set of 25 wheat flour laboratory samples. Test samples consisted of pressed pellets prepared from wheat flour mixed with 30% mm{sup −1} cellulose binder. Experiments were carried out with a LIBS setup consisted of a Q-switched Nd:YAG laser and a spectrometer with Echelle optics and ICCD, and a benchtop EDXRF system fitted with a Rh target X-ray tube and a Si(Li) semiconductor detector. The correlation coefficients from the linear calibration models of P, K, Ca, Mg, S, Fe, Mn and Zn determined by LIBS and/or EDXRF varied from 0.9705 for Zn to 0.9990 for Mg by LIBS, and from 0.9306 for S to 0.9974 for K by EDXRF. The coefficients of variation of measurements varied from 1.2 to 20% for LIBS, and from 0.3 to 24% for EDXRF. The predictive capabilities based on RMSEP (root mean square error of prediction) values were appropriate for the determination of P, Ca, Mg, Fe, Mn and Zn by LIBS, and for P, K, S, Ca, Fe, and Zn by EDXRF. In general, results from the analysis of NIST SRM 1567a Wheat flour by LIBS and EDXRF were in agreement with their certified mass fractions. - Highlights: • Combination of LIBS and EDXRF for quantitative analysis of wheat flour. • Validation performed for determination of P, K, Ca, Mg, S, Fe, Cu, Mn and Zn. • Same test samples can be used for both methods. • Appropriate limits of detection for all tested analytes. • Methods are simple and provide fast and accurate results for routine analysis.

  18. Quantitative X ray analysis system. User's manual and guide to X ray fluorescence technique

    International Nuclear Information System (INIS)

    2009-01-01

    This guide covers trimmed and re-arranged version 3.6 of the Quantitative X ray Analysis System (QXAS) software package that includes the most frequently used methods of quantitative analysis. QXAS is a comprehensive quantitative analysis package that has been developed by the IAEA through research and technical contracts. Additional development has also been carried out in the IAEA Laboratories in Seibersdorf where QXAS was extensively tested. New in this version of the manual are the descriptions of the Voigt-profile peak fitting, the backscatter fundamental parameters' and emission-transmission methods of chemical composition analysis, an expanded chapter on the X ray fluorescence physics, and completely revised and increased number of practical examples of utilization of the QXAS software package. The analytical data accompanying this manual were collected in the IAEA Seibersdorf Laboratories in the years 2006/2007

  19. The determination, by x-ray-fluorescence spectrometry, of noble and base metals in matte-leach residues

    International Nuclear Information System (INIS)

    Austen, C.E.

    1977-01-01

    An accurate and precise method is described for the determination of noble and base metals in matte-leach residues. Preparation of the samples essentially involves fusion with sodium peroxide in a zirconium crucible and leaching with hydrochloric and nitric acids. Matrix correction and calibration are achieved by use of the single-standard calibration method with reference solutions prepared from pure metals or from compounds of the element to be determined

  20. Analysis of solar blocker through portable X-ray fluorescence

    International Nuclear Information System (INIS)

    Ferreira, Diego de Dio; Melquiades, Fabio Luiz; Appoloni, Carlos Roberto; Lopes, Fabio; Lonni, Audrey Stinghen G.; Oliveira, Frederico Minardi de; Duarte, Jose C.

    2009-01-01

    This paper estimates the concentration of TiO 2 by Energy Dispersion X-ray fluorescence (EDXRF) viewing t obtain the FPS due to the physical barrier in the composition of solar blockers, and identifies possible present metals in the samples. A portable EDXRF equipment was used and 27 commercial of different brands and solar protection factors were analysed. Also, three formulations (A, B and C) were prepared and measured estimated in FPS-30 using 5% or TiO 2 . The quantification was performed through calibration curves with 1% to 30% standards of TiO 2 . As result, it was possible to determine the contribution to physical protection in the FPS, associated to the Ti concentration present in some solar blocker samples available in the market. Also, it was possible to detect the presence of various metals in solar protectors, such as Fe, Zn, Br and Sr, and identify chemical elements which were not mentioned and their formulation as well

  1. Submicron hard X-ray fluorescence imaging of synthetic elements.

    Science.gov (United States)

    Jensen, Mark P; Aryal, Baikuntha P; Gorman-Lewis, Drew; Paunesku, Tatjana; Lai, Barry; Vogt, Stefan; Woloschak, Gayle E

    2012-04-13

    Synchrotron-based X-ray fluorescence microscopy (XFM) using hard X-rays focused into sub-micron spots is a powerful technique for elemental quantification and mapping, as well as microspectroscopic measurements such as μ-XANES (X-ray absorption near edge structure). We have used XFM to image and simultaneously quantify the transuranic element plutonium at the L(3) or L(2)-edge as well as Th and lighter biologically essential elements in individual rat pheochromocytoma (PC12) cells after exposure to the long-lived plutonium isotope (242)Pu. Elemental maps demonstrate that plutonium localizes principally in the cytoplasm of the cells and avoids the cell nucleus, which is marked by the highest concentrations of phosphorus and zinc, under the conditions of our experiments. The minimum detection limit under typical acquisition conditions with an incident X-ray energy of 18 keV for an average 202 μm(2) cell is 1.4 fg Pu or 2.9×10(-20) moles Pu μm(-2), which is similar to the detection limit of K-edge XFM of transition metals at 10 keV. Copper electron microscopy grids were used to avoid interference from gold X-ray emissions, but traces of strontium present in naturally occurring calcium can still interfere with plutonium detection using its L(α) X-ray emission. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Study of granitic biotites by X-ray fluorescence analysis: determination of iron, manganese, titanium, calcium, potassium, silicon and aluminium

    International Nuclear Information System (INIS)

    Toubes, R. O.; Bermudez Polonio, J.

    1968-01-01

    A method for the quantitative determination of iron, manganese, titanium, calcium potassium, silicon, and aluminium, is reported, Sample preparation is carried out by the miniature flux technique, and rubidium is used as internal standard for silicon and aluminium. (Author) 5 refs

  3. Development of a technique for the determination of lead and bromine in atmospheric particles by X-ray fluorescence

    Science.gov (United States)

    Sturges, W. T.; Harrison, Roy M.; Dams, R.

    A methodology has been developed for determining the lead and bromine content of atmospheric particles collected on membrane filters. In a novel calibration procedure, standards were prepared by drying fine precipitates of lead molybdate and silver bromide on to filters. Such standards were evidently free from bromine loss during analysis and storage, and more accurately represent real samples than conventional solution-impregnated filters. Elemental loadings in the range 0.1-10μg could be measured. Inhomogeneous efficiency of detection across the surface of samples was noted, and was accounted for by applying correction factors obtained from an intercomparison of XRF and atomic absorption analyses. Good comparability between Br determinations by XRF and neutron activation analysis was found. Problems of noncomparability between standards and samples of low concentration were noted in some cases.

  4. X-ray fluorescence application in the determination of insoluble components in precipitation water at subtropical continental region

    International Nuclear Information System (INIS)

    Solci, Maria Cristina; Pelicho, Alescio Fachim; Aragao, Pedro Henrique Arruda; Nascimento Filho, Virgilio Franco do

    2002-01-01

    Wet and bulk rainwater samples were collected during the year 2001 at Londrina, Brazil. Two phases were analysed, the soluble fraction was obtained with a 0,8 μm filtration and the insoluble particulate material was collected on the cellulose membrane filter. pH and major ions (NO 3 - and SO 4 = ) were determined by ion chromatography. Elemental composition of the filtration residues was conveniently determined by EDXRF technique. The correlation coefficients between some metals in wet and bulk deposition sample were calculated in order to reveal common sources. The metals Fe, Ti and Mn were well correlated indicating their crustal origin. Pb, Zn and Br had high correlations indicating anthropogenic local emissions. (author)

  5. Passive-X-ray fluorescence determination of the plutonium and uranium ratio in burnt-up fuel

    International Nuclear Information System (INIS)

    Zhelev, Z.

    1983-05-01

    This non-destructive method was proposed for comparatively simple and not labour-intensive determination of the Pu and U ratio in WWER-440 (PWR type) reactor spent fuel. For this purpose the mini-tablets (2mm and length 5mm) were irradiated for 65 and 130 days in dry channel of the WWER-440 reactor passed through its active core. The ratio of Pu and U and ratio of the isotopes 134 Cs and 137 Cs were determined by means of KX-rays and gamma-scanning analyses correspondingly. It was shown that there was a simple functional dependance between the ratio of Pu and U and the ratio of Cs isotopes

  6. X-ray fluorescence determination of Au, Pd and Pt from chloride solutions after preconcentration on cellulose filters

    International Nuclear Information System (INIS)

    Gordeeva, V.P.; Glazkova, S.V.; Tsysin, G.I.; Ivanov, V.M.; Zolotov, Yu. A.

    2003-01-01

    The aim of this work was synthesis of new sorption cellulose filters for dynamic preconcentration of Au, Pd and Pt from chloride solutions and subsequent XRF determination of these elements on the filters. New filters were prepared by impregnation of a filter paper with solution of tri-n-octylamine and paraffin in hexane (TOA-filters). The effect of paraffin and TOA concentration in hexane on a content of nitrogen in a filter was studied. It was found that Au(III), Pd(II) and Pt(IV) were quantitatively recovered on the TOA-filters (filtering surface diameter of 23 mm, thickness of 0.15 mm) from 0.5 - 1 M HCl at a flow rates of 2-5 ml min-1 from 10-100 ml of solution. The mathematical model of sorption dynamics was offered for the estimation of potential possibilities of new impregnated sorbents and for the evaluation of optimum dynamic conditions allowing to achieve of maximum concentration efficiency (CE max ). The elements were determined directly on the filters by XRF spectrometer. Palladium was also determined on the TOA-filters after formation of coloured compounds of metal with 4-(2-pyridylazo)resorcinol (PAR) by diffuse reflectance spectroscopy with the calculation of calorimetric characteristics and using test-scale. (authors)

  7. Determination of total As in onion plants growing in contaminated substrates by total reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Lue-Meru Marco Parra

    2011-01-01

    The onion (Allium cepa L.) is one of the most important cultivars in the world and its production level occupies the second place in Venezuela. It becomes important to develop analytical procedures for arsenic determination and to study the effect of this element on the cultures, as well the absorption, transport and translocation processes. A TXRF method for As determination in onions was developed. Two treatments were applied to the onion plants, As contaminated and control. The contaminant was added to the plants to an amount of 100 μg, in a single time 3 weeks after the transplant of plantlets. The green leaves bulbs, and roots together with the stems were separated 45 days after transplant and analyzed by TXRF and HG-AAS for total Arsenic determination. A good agreement was found between these two techniques, demonstrating the accuracy of the TXRF procedure. It was found that the highest concentration corresponded to the root and stems (37 ± 31 μg g -1 ), followed by the bulbs (11 ± 7 μg g -1 ), being the smallest level found in the green leaves (4 ± 3 μg g -1 ). At low As contamination levels of 0.25 μg g -1 , a risk for translocation of the toxic element to the edible parts of the onion plants exists. At this level the normal development of the plant is not affected, being the only exception the root length, which is significantly higher in the contaminated treatment. (author)

  8. A rapid method for the determination of uranium in ores and carbonaceous materials by x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Tolmay, R.T.; Jacobs, J.J.

    1980-01-01

    The determination of uranium by a non-fusion method in a wide range of uranium-bearing materials, e.g. ores, coals, and resins, is described. Matrix effects are corrected for by dilution and fine grinding of the sample with coarse river sand and application of a technique for background correction. The linear calibration range is up to 1000 p.p.m. of U 3 O 8 . It was found that the suitable dilution of resins with river sand and fine grinding makes it possible for up to 6 per cent U 3 O 8 to be determined. Ten samples can be analysed in two-and-a-half hours. The precision and accuracy is 5 and 2 per cent at U 3 O 8 concentrations of 500 and 2000 p.p.m. respectively. The laboratory method, a listing of the computer programme required for the calibration and calculation of the U 3 O 8 concentrations, and instructions for the calculation of the error in the determination are given in the appendices [af

  9. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  10. Preliminary determination of calcium, phosphorus, and the calcium/phosphorus ratio in cortical bone of Chinstrap penguin using synchrotron X-ray fluorescence analysis

    Institute of Scientific and Technical Information of China (English)

    Xie Zhouqing; Cheng Bangbo; Sun Liguang; Huang Yuying; He Wei; Zhao Sanping

    2006-01-01

    Synchrotron radiation X-ray fluorescence (SR-XRF) approach was applied to analyzing of Chinstrap penguin (Pygoscelis Antarctica) cortical bone. The method enabled the in situ determination of Ca and P concentrations and the Ca/P ratio in cortical bone. The preliminary results show that: (1) there is the bone site-related difference for Ca and P concentrations. The mean values for the investigated parameters ( on a dry-weight basis) are: 30.7% (Ca) and 14.9% (P) for the femoral cortical bone, 21.4% (Ca) and 11.5% (P) for wing cortical bone. (2) The variation for the Ca/P ratio in cortical bone is lower than those for Ca and P separately.This is in agreement with the previous report that the specificity of the Ca/P ratio is better than that of Ca and P concentrations and is more reliable for the diagnosis of bone disorders. The authors suggest that further studies be conducted to establish normal values of Ca, P and Ca/P ratio for polar animals and provide a basis for the diagnosis of bone disorders.

  11. Determination of calcium, potassium, manganese, iron, copper and zinc levels in representative samples of two onion cultivars using total reflection X-ray fluorescence and ultrasound extraction procedure

    International Nuclear Information System (INIS)

    Alvarez, J.; Marco, L.M.; Arroyo, J.; Greaves, E.D.; Rivas, R.

    2003-01-01

    The chemical characterization of onion cultivar samples is an important tool for the enhancement of their productivity due to the fact that chemical composition is closed related to the quality of the products. A new sample preparation procedure for elemental characterization is proposed, involving the acid extraction of the analytes from crude samples by means of an ultrasonic bath, avoiding the required digestion of samples in vegetable tissue analysis. The technique of total reflection X-ray fluorescence (TXRF) was successfully applied for the simultaneous determination of the elements Ca, K, Mn, Fe, Cu and Zn. The procedure was compared with the wet ashing and dry ashing procedures for all the elements using multivariate analysis and the Scheffe test. The technique of flame atomic absorption spectrometry (FAAS) was employed for comparison purposes and accuracy evaluation of the proposed analysis method. A good agreement between the two techniques was found when using the dry ashing and ultrasound leaching procedures. The levels of each element found for representative samples of two onion cultivars (Yellow Granex PRR 502 and 438 Granex) were also compared by the same method. Levels of K, Mn and Zn were significantly higher in the 438 Granex cultivar, while levels of Ca, Fe and Cu were significantly higher in the Yellow Granex PRR 502 cultivar

  12. Determination of demineralization depth in tooth enamel exposed to abusive use of whitening gel using micro-Energy Dispersive X ray Fluorescence

    Science.gov (United States)

    Pessanha, Sofia; Coutinho, Sara; Carvalho, Maria Luisa; Silveira, João Miguel; Mata, António

    2017-12-01

    In this work, we present a methodology for the determination of the depth of demineralization in dental enamel caused by extended use of an Over-The-Counter (OTC) whitening product. Teeth whitening is a very common practice in Dentistry, but concerns have been raised regarding the invasiveness of the treatment, especially regarding OTC products, that can be used without medical supervision and sometimes with concentrations of active agent that exceed the allowed regulations. In this work, we studied tooth enamel samples, treated with a whitening product during an extended period of time, both directly on the enamel surface and in the cross-section. Specimens were analyzed using microbeam X-Ray Fluorescence (micro-XRF) using polycapillary optics to obtain a spot down to 25 μm. Due to the relatively large spot size of our setup point analysis of the cross-sections would be inadequate. This way, line scans were performed instead, before and after whitening, and using appropriate data treatment the depth of demineralization was inferred. The used methodology indicated an average demineralization depth of 25 μm, the same order of magnitude as the aprismatic enamel layer.

  13. Energy Dispersive X-Ray Fluorescence Spectrometric Study of ...

    African Journals Online (AJOL)

    MBI

    2017-06-11

    Jun 11, 2017 ... Compositional Differences in Trace Elements in Dried Moringa oleifera ... Ti, Cu, Mo, Fe, Zn, Ni, Re, Eu and Pb using Energy Dispersive X-ray fluorescence ... Africa, Southeast Asia (Valdez-Solana et al., 2015). ... vegetable in many countries, including Nigeria .... of other elements in environmental samples.

  14. X-ray fluorescence spectrometry applied to soil analysis

    International Nuclear Information System (INIS)

    Salvador, Vera Lucia Ribeiro; Sato, Ivone Mulako; Scapin Junior, Wilson Santo; Scapin, Marcos Antonio; Imakima, Kengo

    1997-01-01

    This paper studies the X-ray fluorescence spectrometry applied to the soil analysis. A comparative study of the WD-XRFS and ED-XRFS techniques was carried out by using the following soil samples: SL-1, SOIL-7 and marine sediment SD-M-2/TM, from IAEA, and clay, JG-1a from Geological Survey of Japan (GSJ)

  15. X-ray fluorescence spectrometry - an introduction course

    International Nuclear Information System (INIS)

    Salvador, V.L.R.

    1989-01-01

    The theoretical and experimental principles of the X-ray fluorescence spectrometry, is presented the text is a synthesis of the most important literature in this area. The authors included are: E.P. Bertin, R. Jenkins, J.L. Devries, R. Muller, R. Tertian, F. Claisse e K.L. Willians. (author)

  16. A portable tube exciting X-ray fluorescence analysis system

    International Nuclear Information System (INIS)

    Yang Qiang; Lai Wanchang; Ge Liangquan

    2009-01-01

    Article introduced a portable tube exciting X-ray fluorescence analysis system which is based on arm architecture. Also, we designed Tube control circuit and finished preliminary application. The energy and the intensity of the photon can be adjusted continuously by using the tube. Experiments show that high excitation efficiency obtained by setting the appropriate parameters of the tube for the various elements. (authors)

  17. Research Note: Energy dispersive x-ray fluorescence analysis ...

    African Journals Online (AJOL)

    Energy Dispersive X-Ray fluorescence (EDXRF) technique for the analysis of geological, biological and environmental samples is described. The technique has been applied in the analysis of 10 (geological, biological, environmental) standard reference materials. The accuracy and precision of the technique were attested ...

  18. Worldwide Open Proficiency Test for X ray Fluorescence Laboratories PTXRFIAEA08: Determination of Minor and Trace Elements in Natural Soil

    International Nuclear Information System (INIS)

    2014-01-01

    The IAEA assists Member State laboratories to maintain their readiness by producing reference materials, developing standardized analytical methods, and conducting interlaboratory comparisons and proficiency tests as tools for quality control. To ensure a reliable, worldwide, rapid and consistent response, the IAEA Nuclear Spectrometry and Applications Laboratory organizes tests for Member State laboratories. This publication presents the results of the worldwide proficiency test PTXRFIAEA08 on the determination of minor and trace elements in natural soil. Methodologies, a data evaluation approach, a summary evaluation of each element and individual evaluation reports for each laboratory are also described. The test was carried out within the IAEA project Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of the project was to enhance the capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health and agriculture, and in monitoring and evaluating environmental pollution. This proficiency test was designed to identify analytical problems and to support Member State laboratories in improving the quality of their analytical results, maintaining their accreditation and providing a regular forum for discussion and technology transfer in this area. The type of sample and the concentration levels of the analytes were designed to enable the identification of potential analytical problems

  19. Worldwide Open Proficiency Test for X Ray Fluorescence Laboratories PTXRFIAEA/06: Determination of Minor and Trace Elements in Grass Mixture

    International Nuclear Information System (INIS)

    2011-01-01

    The IAEA assists its Member States laboratories to maintain their readiness by producing reference materials, by developing standardized analytical methods, and by conducting interlaboratory comparisons and proficiency tests as tools for quality control. To ensure a reliable worldwide, rapid and consistent response, the IAEA Nuclear Spectrometry and Applications Laboratory in Seibersdorf, Austria organises tests. This summary report presents the results of the worldwide proficiency test IAEA-PTXRF-06 on the determination of minor and trace elements in a grass mixture. Methodologies, data evaluation approach, summary evaluation of each element and individual evaluation reports for each laboratory are also described. The test was carried out under IAEA Project 1.4.3.4 (D.3.03), Nuclear Spectrometry for Analytical Applications, under the Nuclear Science Programme. The main objective of this project is to enhance the capability of interested Member States in effective utilization of nuclear spectrometries and analytical services in industry, human health, agriculture, and in monitoring and evaluation of environmental pollution. This proficiency test was designed to identify analytical problems, to support IAEA Member States laboratories to improve the quality of their analytical results, to maintain their accreditation and to provide a regular forum for discussion and technology transfer in this area. The type of sample and the concentration levels of the analytes were designed in a way to enable identification of potential analytical problems. The next proficiency test exercise is expected to be organized in 2010

  20. The determination of molybdenum, by x-ray-fluorescence spectrometry, in ores, residues, and concentrates of tin and tungsten

    International Nuclear Information System (INIS)

    Spimpolo, G.F.

    1985-01-01

    Three methods were investigated that would minimize or possibly eliminate the matrix variations in the analysis of molybdenum, and possibly simplify the existing method for the analysis of tin and tungsten, which often occur together with molybdenum. The three methods involve the use of back-scattered radiation in the determination of the mass-absorption coefficient of unknown samples, the use of a background ratio with an exponent that minimizes the effect of matrix variations, and the use of an internal standard that shows the same matrix variation as the analyte. In the first two approaches, the sample preparation and analysis are much simpler than in the third, but, for the great variety of mass absorptions encountered, the internal-standard method proved to be the most successful. The precision of analysis for molybdenum by that method ranges from a relative standard deviation of 0,06 at 50μg/g to 0,02 at 1 000 μg/g. The lower limit of detection is 4 μg/g. The recommended laboratory procedure for the method using internal standards is detailed in an appendix

  1. Measuring and interpreting X-ray fluorescence from planetary surfaces.

    Science.gov (United States)

    Owens, Alan; Beckhoff, Burkhard; Fraser, George; Kolbe, Michael; Krumrey, Michael; Mantero, Alfonso; Mantler, Michael; Peacock, Anthony; Pia, Maria-Grazia; Pullan, Derek; Schneider, Uwe G; Ulm, Gerhard

    2008-11-15

    As part of a comprehensive study of X-ray emission from planetary surfaces and in particular the planet Mercury, we have measured fluorescent radiation from a number of planetary analog rock samples using monochromatized synchrotron radiation provided by the BESSY II electron storage ring. The experiments were carried out using a purpose built X-ray fluorescence (XRF) spectrometer chamber developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The XRF instrumentation is absolutely calibrated and allows for reference-free quantitation of rock sample composition, taking into account secondary photon- and electron-induced enhancement effects. The fluorescence data, in turn, have been used to validate a planetary fluorescence simulation tool based on the GEANT4 transport code. This simulation can be used as a mission analysis tool to predict the time-dependent orbital XRF spectral distributions from planetary surfaces throughout the mapping phase.

  2. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  3. Investigation of Pink Tourmalines by X-ray Fluorescent Technique

    International Nuclear Information System (INIS)

    Sangariyavanich, A.; Na Songkhla, S.; Pimjum, S.

    1998-01-01

    X-ray fluorescent technique has been employed in the study of trace elements in six samples of gamma irradiated pink tourmalines, namely, red-pink (rubellite), light-pink, orange-pink, brownish orange-pink, purple red and purple orange-pink. The analysis of their characteristic X-ray indicated the existence of manganese in all samples. Trace amounts of iron, zinc, lead, bismuth or gallium were also investigated in certain samples. Since these elements were not present in red-pink tourmaline, therefore, we believed that manganese is the major cause of pink color in tourmaline while other elements produce various types of pink color

  4. X-ray fluorescence analysis of neodymium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Mohile, A.N.

    1977-01-01

    An X-ray fluorescence method for the determination of cesium, praseodymium, samarium, europium and gadolinium in pure neodymium oxide and oxalate is described. The oxide sample is converted to oxalate and mixed with a binder (boric acid) to obtain a pressed circular pellet. The amount of sample needed for analysis is reduced by making use of the double layer pellet technique. A tungsten target X-ray tube is employed to irradiate the sample and a Philips PW 1220 semiautomatic X-ray spectrometer with a LiF (200) crystal is used to analyse the fluorescent X-rays. The minimum determination limit is 0.01 percent for all rare earths determined except for europium for which the limit is 0.005 percent. Three sigma detection limits have been calculated. (author)

  5. Two different preparation techniques for trace element determination of single Daphnia specimen using total reflection x-ray fluorescence analysis (TXRF)

    International Nuclear Information System (INIS)

    Woelfl, S.; Mages, M.

    2000-01-01

    Bio accumulation gives first information about the bio-availability of elements in waters and becomes more and more important for the characterization of the water quality. The use of common analytical techniques like ICP-MS and AAS requires large quantities of biologic sample material. Single preparation for example of Daphnia, a common species for bio-test experiments, are hardly possible with these procedures. Therefore alternatively quantitative TXRF element determination of individually prepared Daphnia was developed. Two preparation techniques for single freshwater crustacean specimen from a eutrophic branch of the river Elbe in the 'Rothehorn Park', Magdeburg (Daphnia: dry weight: 10 - 50 μg individuum -1 ) had been tested: (1) Wet preparation: the single Daphnia specimen had been washed with 0.45 μm filtered lake water and put onto quartz sample carriers. After air drying, the body length were determined in order to calculate the dry weight according to previously established body lengths-dry weight relationships. (2) Dry preparation: after collection specimen were washed with 0.45 μm filtered lake water and frozen in liquid nitrogen. The individual lyophilisated dried Daphnia were weighted using an ultrafine micro-balance and put onto quartz sample carriers. After preparation, addition of some μl Gallium standard solution and air drying the individual Daphnia were digested at the quartz sample carriers with 10 μl HNO 3 on a hot plate and dried once more. Finally the element concentrations were determined using a EXTRA IIA total-reflection x-ray fluorescence spectrometer. As a result of these investigations we can conclude that both, the 'dry' and 'wet' preparation method can be used for the element determination in small single crustaceans using TXRF spectrometry. It seems that the 'dry' method yields more precise results, but the wet method is easier to handle in field when samples cannot be fixed with liquid nitrogen. (author)

  6. The use of x-ray fluorescence technique (XRF) in the determination of trace elements in environmental study: a case study for sediments and soils

    International Nuclear Information System (INIS)

    Hamzah Mohamad

    1997-01-01

    A specific X-ray fluorescence technique (XRF) was developed to determine the concentrations of nine common and significant trace elements in sediments and soils, i.e. two of the common materials used in environmental studies. The elements are Ba, Cr, Cu, Fe, Mn, Ni, Pb, V and Zn. A total of 22 international reference materials of rocks, soils, minerals, ores and sediments were employed to construct nine calibration curves, all of which depict linear correlation of concentration-intensity, with correlation coefficients of 0.9 or better. The accuracy of determination is implied from the relative differences between the observed and suggested values in four reference materials: USGS SCO-1, shale; CCRMP SO-1, soil; CCRMP CO-2, soil; and SARM 42, soil. The determinations of four elements are considered as accurate, with relative errors of smaller than 10%; they are Fe (5%), Mn (6%), Cr (8%), and Cu (9%). Only a moderate accuracy has been achieved in the determinations of Ba (13%), Zn (18%) and V (21 %). Ni and Ph results are associated with larger errors. The developed technique is considered rapid, whereby nine elements in 30 samples in the form of pressed powder briquettes can be analysed in 8 hours. Without extrapolating the calibration curves, the method is suitable to analyse elements in soils and sediments in the following ranges of concentrations: Ba, 0-1500 ppm; Cr, 0-3000 ppm; Cu, 0-300 ppm; Fe, 0.7%; Mn, 0-1000 ppm; Ni, 0-300 ppm; Pb, 0-70 ppm; V, 0-300 ppm and Zn, 0-270 ppm

  7. Background approximation in automatic qualitative X-ray-fluorescent analysis

    International Nuclear Information System (INIS)

    Jordanov, J.; Tsanov, T.; Stefanov, R.; Jordanov, N.; Paunov, M.

    1982-01-01

    An empirical method of finding the dependence of the background intensity (Isub(bg) on the wavelength is proposed, based on the approximation of the experimentally found values for the background in the course of an automatic qualitative X-ray fluorescent analysis with pre-set curve. It is assumed that the dependence I(lambda) will be well approximated by a curve of the type Isub(bg)=(lambda-lambda sub(o)sup(fsub(1)(lambda))exp[fsub(2)(lambda)] where fsub(1) (lambda) and f 2 (lambda) are linear functions with respect to the sought parameters. This assumption was checked out on a ''pure'' starch background, in which it is not known beforehand which points belong to the background. It was assumed that the dependence I(lambda) can be found from all minima in the spectrum. Three types of minima has been distinguished: 1. the lowest point between two well-solved X-ray lines; 2. a minimum obtained as a result of statistical fluctuations of the measured signal; 3. the lowest point between two overlapped lines. The minima strongly deviating from the background are removed from the obtained set. The sum-total of the remaining minima serves as a base for the approximation of the dependence I(lambda). The unknown parameters are determined by means of the LSM. The approximated curve obtained by this method is closer to the real background than the background determined by the method described by Kigaki Denki, as the effect of all recorded minima is taken into account. As an example the PbTe spectrum recorded with crystal LiF 220 is shown graphically. The curve well describes the background of the spectrum even in the regions in which there are no minima belonging to the background. (authors)

  8. X-ray fluorescence analysis of erbium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Thomas, A.

    1981-01-01

    A method for the determination of Tb, Dy, Ho, Tm, Yb, Lu and Y oxides in Er 2 O 3 is described. 450 mg sample in the oxalate form is mixed with 150 mg boric acid binding material and pressed into a 1.25 inch diameter pellet over a supporting pellet of boric acid. The sample is then irradiated by X-rays from a tungsten tube and the fluorescent X-rays are dispersed by a LiF (200) crystal in a Philips PW 1220 semiautomatic X-ray fluorescence spectrometer. The intensities of characteristic X-rays of the impurity elements are measured by a flow proportional counter for all elements except yttrium for which the intensities are measured by a scintillation counter. The lowest determination limit is 0.005% for all impurities except for Yb for which it is 0.01%. Calculations for theoretical detection limit are given. (author)

  9. X-ray fluorescence analysis of ytterbium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Thomas, A.

    1982-01-01

    An XRF method for the determination of Ho, Er, Tm, Lu and Y oxides in Yb 2 O 3 is described. 450 mg sample in the oxalate form is mixed with 150 mg boric acid binding material and pressed into 1.25 inch diameter pellet over a supporting pellet of boric acid. The sample is irradiated by X-rays from a tungsten tube and the fluorescent X-rays are dispersed by a LiF(200) crystal in a Philips PW 1220 semiautomatic X-ray fluorescence spectrometer. The intensities of characteristic X-rays of the impurity elements are measured by a flow proportional counter or a scintillation counter. The lowest determination limit is 0.005% for Ho, Er, Tm and Y and 0.01% for Lu. Calculations for theoretical detection limit, standard deviation and uncertainty are done and presented. (author)

  10. Determination of ultra trace contaminants on silicon wafer surfaces using total-reflection X-ray fluorescence TXRF 'state-of-the-art'

    Science.gov (United States)

    Pahlke, S.; Fabry, L.; Kotz, L.; Mantler, C.; Ehmann, T.

    2001-11-01

    In a well balanced system of highly motivated, well trained personnel and automated equipment, pure reagents and bulk media, cleanrooms and integrated data management, total-reflection X-ray fluorescence (TXRF) can and must contribute to quality assurance and process stability, support and canalize creative engineering by continuous learning about materials and processes. TXRF has the advantage of controlled one-point calibration, a linear dynamic range of three orders of magnitude, high grade of automation in operation and data management, high up-time, and a simple control of data plausibility.

  11. Energy dispersion X-ray fluorescence techniques in water pollution analysis

    International Nuclear Information System (INIS)

    Holynska, B.

    1980-01-01

    Advantages and limitations of energy dispersion X-ray fluorescence methods for analysis of pollutants in water are discussed. The necessary equipment for X-ray measurement of insoluble and dissolved trace metals in water is described. Different techniques of enrichment of trace metals are presented: ion exchange on selective Chelex-100 exchanger, precipitation with chelating agents DDTC and APDC, and adsorption on activated carbon. Some results obtained using different preconcentration methods for trace metals determination in different waters are presented. (author)

  12. Elemental analysis of air particulate samples in Jakarta area by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Yumiarti; Yusuf, M.; Mellawati, June; Menry, Yulizon; Surtipanti S

    1998-01-01

    Determination of elements in air particulate samples collected from Jakarta, especially from industrial area Pulo Gadung, also from residence, office, and recreation sites had been carried out. The samples collected periodically from August through December 1996. The elements were analyzed by X-ray fluorescence spectrometry method. Quantitative and qualitative analyses were done using QXAS AXIL (Quantitative X-ray Analysis System of x-ray Spectra by Iterative Least squares fitting) and QAES (Quantitative Analyses of Environmental Samples) package program. Results of the analyses showed that the content of heavy metal elements in air particulate samples from all areas studied were still below the maximum permissible concentration. (authors)

  13. X-ray fluorescence in some medium-Z elements excited by 59.5 keV photons

    International Nuclear Information System (INIS)

    Han, I.; Shahin, M.; Demir, L.; Narmanli, E.

    2010-01-01

    K X-ray fluorescence parameters cross sections and average shell fluorescence yields) for selected ten elements in the atomic range 42 ≤ Z ≤ 66 have been experimentally determined at photon excitation energy of 59.5 keV. K X-rays emitted from the samples have been counted by a Si (Li) detector. The K spectra for investigated elements have been derived from the measured K shell X-ray spectra by peak fitting process. Experimental results of K X-ray fluorescence parameters have been compared with theory. In general there is an agreement within the standard uncertainties of the experimental and theoretical values

  14. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  15. Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lens

    International Nuclear Information System (INIS)

    Emoto, T.; Sato, Y.; Konishi, Y.; Ding, X.; Tsuji, K.

    2004-01-01

    A polycapillary X-ray lens is an effective optics to obtain a μm-size X-ray beam for micro-X-ray fluorescence spectrometry (μ-XRF). We developed a μ-XRF instrument using a polycapillary X-ray lens, which also enabled us to perform Grazing Exit μ-XRF (GE-μ-XRF). The evaluated diameter of the primary X-ray beam was 48 μm at the focal distance of the X-ray lens. Use of this instrument enabled two-dimensional mapping of the elemental distributions during growth of the plant 'Quinoa'. The results of the mapping revealed elemental transition during growth. In addition, a small region of thin film was analyzed by GE-μ-XRF. We expect that GE-μ-XRF will become an effective method of estimating the film thickness of a small region

  16. Development and applications of grazing exit micro X-ray fluorescence instrument using a polycapillary X-ray lens

    Energy Technology Data Exchange (ETDEWEB)

    Emoto, T.; Sato, Y.; Konishi, Y.; Ding, X.; Tsuji, K. E-mail: tsuji@a-chem.eng.osaka-cu.ac.jp

    2004-08-31

    A polycapillary X-ray lens is an effective optics to obtain a {mu}m-size X-ray beam for micro-X-ray fluorescence spectrometry ({mu}-XRF). We developed a {mu}-XRF instrument using a polycapillary X-ray lens, which also enabled us to perform Grazing Exit {mu}-XRF (GE-{mu}-XRF). The evaluated diameter of the primary X-ray beam was 48 {mu}m at the focal distance of the X-ray lens. Use of this instrument enabled two-dimensional mapping of the elemental distributions during growth of the plant 'Quinoa'. The results of the mapping revealed elemental transition during growth. In addition, a small region of thin film was analyzed by GE-{mu}-XRF. We expect that GE-{mu}-XRF will become an effective method of estimating the film thickness of a small region.

  17. X-ray fluorescence in Member States (Italy): Full field X-ray fluorescence imaging with high-energy and high-spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Romano, F. P.; Masini, N.; Pappalardo, L., E-mail: romanop@lns.infn.it [IBAM, CNR, Via Biblioteca 4, 95124 Catania (Italy); Cosentino, L.; Gammino, S.; Mascali, D.; Rizzo, F. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy)

    2014-02-15

    A full field X-ray camera for the X-Ray Fluorescence imaging of materials with high-energy and high-spatial resolution was designed and developed. The system was realized by coupling a pinhole collimator with a positionsensitive CCD detector. X-Ray fluorescence is induced on the samples by irradiation with an external X-ray tube. The characteristic X-ray spectra of the investigated materials are obtained by using a multi-frames acquisition in single-photon counting. The energy resolution measured at the Fe-Kα line was 157 eV. The spatial resolution of the system was determined by the analysis of a sharp-edge at different magnification values; it was estimated to be 90 μm at a magnification value of 3.2x and 190 μm at 0.8x. The present set-up of the system is suited to analyze samples with dimensions up to 5x4 cm{sup 2}. Typical measurement time is in the range between 1h to 4 h. (author)

  18. Monitoring body iron burden using X-ray fluorescence (XRF)

    International Nuclear Information System (INIS)

    Farquharson, M.J.; Bagshaw, A.P.

    2001-01-01

    X-ray fluorescence, using Cu K alpha and K beta radiation, has been used to measure the Fe content of skin of two groups of rats, one Fe overloaded and one control group. These skin Fe levels were compared to the liver and heart Fe levels measured using colorimetry. Correlation coefficients of 0.86 and 0.88 respectively were found indicating that skin Fe levels may be a potential marker for body iron burden.

  19. Analysis of eight argonne premium coal samples by X-ray fluorescence spectrometry

    Science.gov (United States)

    Evans, J.R.; Sellers, G.A.; Johnson, R.G.; Vivit, D.V.; Kent, J.

    1990-01-01

    X-ray fluorescence spectrometric methods were used in the analysis of eight Argonne Premium Coal Samples. Trace elements (Cr, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb, Ba, La, and Ce) in coal ash were determined by energy-dispersive X-ray fluorescence spectrometry; major elements (Na, Mg, Al, Si, P, S, K, Ca, Ti, Mn, and Fe) in coal ash and trace elements (Cl and P) in whole coal were determined by wavelength-dispersive X-ray fluorescence spectrometry. The results of this study will be used in a geochemical database compiled for these materials from various analytical techniques. The experimental XRF methods and procedures used to determine these major and trace elements are described.

  20. Portable x-ray fluorescence spectrometer for Works of art

    International Nuclear Information System (INIS)

    Mendoza, A.; Griesser, A.

    2001-01-01

    X-ray fluorescence is an analytical technique of prier importance in archaeometry, for restoration and art history investigation; it is because of non-destructive and multi-elemental character of the analysis simplicity and high speed of operation, ability to produce immediate analytical results for the objects, which can neither be sampled nor removed to the laboratory Recent advances in X-ray tubes, X-ray detectors and electronic provided an opportunity to produce portable high resolution XRF spectrometers characterized by a good reliability and analytical performance; in this paper a prototype portable XRF spectrometer based on a small size, low power X-ray tube and a thermometrically cooled Si-Pin detector is described. The spectrometer provides a possibility for direct and secondary target excitation geometry use of proper secondary target and filter and size adjustment of the primary photon bean by using a set of different beam collimators; the portable XRF spectrometer was successfully applied to study art objects in the Art History Museum in Vienna, including such objects as old master paintings bronze and brass alloys of antique as well as Renaissance objects and silver/copper coins produced at different locations. Quantitative and Quantitative analysis were amedee depending of the curator questions and discussed from the point of view of art History. The importance of the results for restoration and authentification of the art objects is also emphasized

  1. Renal function measured by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Boijsen, M.; Jacobsson, L.; Tylen, U.; Sahlgrenska Sjukhuset, Goeteborg

    1987-01-01

    In twenty-six patients injected with metrizoate during urography, plasma was analyzed for iodine concentration using X-ray fluorescence analysis, and total plasma clearance of contrast medium was calculated. Total plasma clearance of 51 Cr-EDTA was also determined, but not simultaneously, in order to find out if the urographic procedure would influence the kidneys to such an extent that the contrast medium clearance value would differ much from the 51 Cr-EDTA clearance value. The errors in the method were assessed and the total error of the contrast medium clearance determination was calculated. When comparing 51 Cr-EDTA and metrizoate clearance a correlation of 0.94 and a mean ratio of 1.046 (SD 0.138) was found. The assessable errors cannot fully explain the standard deviation, which might indicate a transient change in kidney function related to elements of the urographic procedure such as laxation with possible dehydration and/or the contrast medium dose. (orig.)

  2. Investigation of elemental distribution in lung samples by X-ray fluorescence microtomography

    International Nuclear Information System (INIS)

    Pereira, Gabriela R.; Rocha, Henrique S.; Lopes, Ricardo T.

    2007-01-01

    X-Ray Fluorescence Microtomography (XRFCT) is a suitable technique to find elemental distributions in heterogeneous samples. While x-ray transmission microtomography provides information about the linear attenuation coefficient distribution, XRFCT allows one to map the most important elements in the sample. The x-ray fluorescence tomography is based on the use of the X-ray fluorescence emitted from the elements contained in a sample so as to give additional information to characterize the object under study. In this work a rat lung and two human lung tissue samples have been investigated in order to verify the efficiency of the system in determination of the internal distribution of detected elements in these kinds of samples and to compare the elemental distribution in the lung tissue of an old human and a fetus. The experiments were performed at the X-Ray Fluorescence beamline (XRF) of the Brazilian Synchrotron Light Source (LNLS), Campinas, Brazil. A white beam was used for the excitation of the elements and the fluorescence photons have been detected by a HPGe detector. All the tomographies have been reconstructed using a filtered-back projection algorithm. It was possible to visualize the distribution of high atomic number elements on both, artificial and tissues samples. It was compared the quantity of Zn, Cu and Fe for the lung human tissue samples and verify that these elements have a higher concentration on the fetus tissue sample than the adult tissue sample. (author)

  3. Relative probabilities of the uranium isotopes for thorium x-ray emission and fluorescence of uranium x-rays

    International Nuclear Information System (INIS)

    Parker, J.L.

    1991-01-01

    Both thorium x-rays from decaying uranium isotopes and self-fluoresced uranium x-rays are prominent in high-resolution gamma-ray spectra of uranium-bearing materials. Useful application of the information carried by those x-rays has been curtailed because the probabilities of the uranium isotopes for thorium x-ray emission and for uranium x-ray fluorescence have not been known. By analyzing enrichment-meter geometry spectra from uranium oxide standards whose enrichments ranged from 0.7% to 91%, relative values, primarily, have been obtained for the probabilities of both processes. Thorium x-ray emission is very heavily dominated by 235 U. In all ordinarily occurring uranium isotopic distributions, thorium x-rays may be used as a valid 235 U signature. The probability for a thorium K α1 x-ray to be emitted in the decay of a 235 U atom is 0.048 ±0.002. In infinitely thick uranium oxide materials, the relative ratios of effectiveness for self-fluorescence, on a per unit mass basis, are approximately 234 U : 235 U : 236 U : 238 U = 1.13 : 1.00 : 0.52 : 0.028. on a per decay basis, the approximate ratios are 0.00039 : 1.00 : 0.017 : 0.18. These results imply that, contrary to what has often been stated, gamma rays are far more important than alpha particles in the self-fluorescence of uranium. Because of the importance of gamma-ray self-fluorescence, the uranium x-ray yield will be somewhat influenced by the size, shape, and composition of the materials. 4 refs., 1 fig

  4. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Innis, Vallerie Ann A.

    2006-01-01

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  5. Trends in environmental science using microscopic X-ray fluorescence

    International Nuclear Information System (INIS)

    Fittschen, Ursula Elisabeth Adriane; Falkenberg, Gerald

    2011-01-01

    Microscopic X-ray fluorescence (micro-XRF) is a versatile tool in environmental analysis. We review work done in this field from 2008 to 2010 and highlight new aspects. Overall, there is a strong trend to combine fluorescence data with other data like diffraction or absorption spectroscopy. Also, the use of laboratory based instrumentation has become wide spread as more commercial instruments are available. At laboratories and synchrotron sites the trend towards higher spatial resolution is still persistent hitting sub micrometer values in case of synchrotron set ups.

  6. Trends in environmental science using microscopic X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, Ursula Elisabeth Adriane, E-mail: ursula.fittschen@chemie.uni-hamburg.de [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Falkenberg, Gerald [Deutsches Elektronen-Synchrotron, Notkestr. 85, 22603 Hamburg (Germany)

    2011-08-15

    Microscopic X-ray fluorescence (micro-XRF) is a versatile tool in environmental analysis. We review work done in this field from 2008 to 2010 and highlight new aspects. Overall, there is a strong trend to combine fluorescence data with other data like diffraction or absorption spectroscopy. Also, the use of laboratory based instrumentation has become wide spread as more commercial instruments are available. At laboratories and synchrotron sites the trend towards higher spatial resolution is still persistent hitting sub micrometer values in case of synchrotron set ups.

  7. X-ray fluorescence analysis of bimetallic complexes on the basis of tantalocene trihydride

    International Nuclear Information System (INIS)

    Shurupova, T.I.; Sokolova, T.A.

    1989-01-01

    Methods of X-ray fluorescence determination of metals in tantalocene trihydride complexes of Cp 2 TaH 3 ·nMeHalm composition where Me=Cu, Mg, Hal=Cl, I, n=1 or 2, m=1 or 2 are developed. To obtain the form, stable in relation to the air oxygen and water vapours, the complexes were burut off up to metal oxides. Possibility of direct X-ray fluorescent determination is tested taking the most stable iodide copper-containing complex as an example

  8. A new X-ray pinhole camera for energy dispersive X-ray fluorescence imaging with high-energy and high-spatial resolution

    Energy Technology Data Exchange (ETDEWEB)

    Romano, F.P., E-mail: romanop@lns.infn.it [IBAM, CNR, Via Biblioteca 4, 95124 Catania (Italy); INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Altana, C. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy); Cosentino, L.; Celona, L.; Gammino, S.; Mascali, D. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Pappalardo, L. [IBAM, CNR, Via Biblioteca 4, 95124 Catania (Italy); INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Rizzo, F. [INFN-LNS, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Fisica e Astronomia, Università di Catania, Via S. Sofia 64, 95123 Catania (Italy)

    2013-08-01

    A new X-ray pinhole camera for the Energy Dispersive X-ray Fluorescence (ED-XRF) imaging of materials with high-energy and high-spatial resolution, was designed and developed. It consists of a back-illuminated and deep depleted CCD detector (composed of 1024 × 1024 pixels with a lateral size of 13 μm) coupled to a 70 μm laser-drilled pinhole-collimator, positioned between the sample under analysis and the CCD. The X-ray pinhole camera works in a coaxial geometry allowing a wide range of magnification values. The characteristic X-ray fluorescence is induced on the samples by irradiation with an external X-ray tube working at a maximum power of 100 W (50 kV and 2 mA operating conditions). The spectroscopic capabilities of the X-ray pinhole camera were accurately investigated. Energy response and energy calibration of the CCD detector were determined by irradiating pure target-materials emitting characteristic X-rays in the energy working-domain of the system (between 3 keV and 30 keV). Measurements were performed by using a multi-frame acquisition in single-photon counting. The characteristic X-ray spectra were obtained by an automated processing of the acquired images. The energy resolution measured at the Fe–Kα line is 157 eV. The use of the X-ray pinhole camera for the 2D resolved elemental analysis was investigated by using reference-patterns of different materials and geometries. The possibility of the elemental mapping of samples up to an area of 3 × 3 cm{sup 2} was demonstrated. Finally, the spatial resolution of the pinhole camera was measured by analyzing the profile function of a sharp-edge. The spatial resolution determined at the magnification values of 3.2 × and 0.8 × (used as testing values) is about 90 μm and 190 μm respectively. - Highlights: • We developed an X-ray pinhole camera for the 2D X-ray fluorescence imaging. • X-ray spectra are obtained by a multi-frame acquisition in single photon mode. • The energy resolution in the X-ray

  9. Development of glancing-incidence and glancing-take-off X-ray fluorescence apparatus for surface and thin-film analyses

    International Nuclear Information System (INIS)

    Tsuji, Kouichi; Wagatsuma, Kazuaki; Yamada, Takashi; Utaka, Tadashi

    1997-01-01

    We have studied X-ray fluorescence analysis under glancing incidence and glancing take-off conditions. Recently, we have developed a third apparatus for detecting glancing-incidence and take-off X-ray fluorescence, which makes it possible to measure the incident-angle dependence, the take-off-angle dependence. X-ray reflectivity, and X-ray diffraction. Primarily, we have measured the take-off angular dependence of X-ray fluorescence using this apparatus. Glancing take-off X-ray fluorescence has some advantages in comparison with glancing-incidence X-ray fluorescence. The surface density and the absolute angles were determined by analysing the take-off angle dependence of the fluorescent X-rays emitted from identical atoms with the aid of the reciprocity theorem. (Author)

  10. A Brazilian tree collection analyzed by X ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, H; Fernandes, E A.N.; Ferraz, E S.B. [Centro de Energia Nuclear na Agricultura, Universidade de Sao Paulo, Laboratorio de Radioisotopos, Piracicaba (Brazil); Haselberger, N; Markowicz, A [International Atomic Energy Agency, Seibersdorf (Austria)

    2000-06-01

    The analysis of the inorganic components of wood is of great interest for several reasons, including the acquisition of basic data creating a data base of values for individual species. Knowing the wide variability in matrix composition (lignin, oil, resin, silica) and densities (0.39-1.09 g cm{sup -3}), 40 species of trees were analysed by X ray fluorescence (XRF) to determine the concentrations of Br, Ca, Cu, K, Mn, Pb, Rb, Sr, and A. This technique is widely used because of its accuracy and simplicity of sample preparation, normally complex for this type of biological material. This multi-elemental analysis has proven suitable for wood, a material in which a wide range for each element was encountered in the different species studied: 0.3-5.2 for Br, 126-9074 for Ca, 2.2-11 for Cu, 108-5873 for K, 3.1-134 for Mn, 0.5-4.7 for Pb, 0.3-20 for Rb, 1.2-120 for Sr, and 1.1-20 for Zn (values given in {mu}g g{sup -1}). (author)

  11. A Brazilian tree collection analyzed by X ray fluorescence

    International Nuclear Information System (INIS)

    Oliveira, H.; Fernandes, E.A.N.; Ferraz, E.S.B.; Haselberger, N.; Markowicz, A.

    2000-01-01

    The analysis of the inorganic components of wood is of great interest for several reasons, including the acquisition of basic data creating a data base of values for individual species. Knowing the wide variability in matrix composition (lignin, oil, resin, silica) and densities (0.39-1.09 g cm -3 ), 40 species of trees were analysed by X ray fluorescence (XRF) to determine the concentrations of Br, Ca, Cu, K, Mn, Pb, Rb, Sr, and A. This technique is widely used because of its accuracy and simplicity of sample preparation, normally complex for this type of biological material. This multi-elemental analysis has proven suitable for wood, a material in which a wide range for each element was encountered in the different species studied: 0.3-5.2 for Br, 126-9074 for Ca, 2.2-11 for Cu, 108-5873 for K, 3.1-134 for Mn, 0.5-4.7 for Pb, 0.3-20 for Rb, 1.2-120 for Sr, and 1.1-20 for Zn (values given in μg g -1 ). (author)

  12. The determination of Fe, Mn and Ca in sintered iron and blast-furnace slag by X-ray fluorescent analyses of energy and wave dispersion-comparison of results

    International Nuclear Information System (INIS)

    Dworak, B.; Gajek, Sz.

    1980-01-01

    The results of sintered iron and of blast-furnace slag examination obtained by X-ray fluorescent analyses of energy and of wave dispersion are compared. They show that the methods are comparable for such elements as Ca and Fe, whereas for Mn (in sinter) the X-ray fluorescent analysis of wave dispersion is less precise. (author)

  13. Gaseous detectors for energy dispersive X-ray fluorescence analysis

    Science.gov (United States)

    Veloso, J. F. C. A.; Silva, A. L. M.

    2018-01-01

    The energy resolution capability of gaseous detectors is being used in the last years to perform studies on the detection of characteristic X-ray lines emitted by elements when excited by external radiation sources. One of the most successful techniques is the Energy Dispersive X-ray Fluorescence (EDXRF) analysis. Recent developments in the new generation of micropatterned gaseous detectors (MPGDs), triggered the possibility not only of recording the photon energy, but also of providing position information, extending their application to EDXRF imaging. The relevant features and strategies to be applied in gaseous detectors in order to better fit the requirements for EDXRF imaging will be reviewed and discussed, and some application examples will be presented.

  14. Quantitative analysis by computer controlled X-ray fluorescence spectrometer

    International Nuclear Information System (INIS)

    Balasubramanian, T.V.; Angelo, P.C.

    1981-01-01

    X-ray fluorescence spectroscopy has become a widely accepted method in the metallurgical field for analysis of both minor and major elements. As encountered in many other analytical techniques, the problem of matrix effect generally known as the interelemental effects is to be dealt with effectively in order to make the analysis accurate. There are several methods by which the effects of matrix on the analyte are minimised or corrected for and the mathematical correction is one among them. In this method the characteristic secondary X-ray intensities are measured from standard samples and correction coefficients. If any, for interelemental effects are evaluated by mathematical calculations. This paper describes attempts to evaluate the correction coefficients for interelemental effects by multiple linear regression programmes using a computer for the quantitative analysis of stainless steel and a nickel base cast alloy. The quantitative results obtained using this method for a standard stainless steel sample are compared with the given certified values. (author)

  15. Determination of U, Th and K in bricks by gamma-ray spectrometry, X-ray fluorescence analysis and neutron activation analysis

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.; Gregorová, E.

    2017-11-01

    Knowledge of the content of natural radionuclides in bricks can be important in some cases in dosimetry and application of ionizing radiation. Dosimetry of naturally occurring radionuclides in matter (NORM) in general is one of them, the other one, related to radiation protection, is radon exposure evaluation, and finally, it is needed for the thermoluminescence (TL) dating method. The internal dose rate inside bricks is caused mostly by contributions of the natural radionuclides 238U, 232Th, radionuclides of their decay chains, and 40K. The decay chain of 235U is usually much less important. The concentrations of 238U, 232Th and 40K were measured by various methods, namely by gamma-ray spectrometry, X-ray fluorescence analysis (XRF), and neutron activation analysis (NAA) which was used as a reference method. These methods were compared from the point of view of accuracy, limit of detection (LOD), amount of sample needed and sample handling, time demands, and instrument availability.

  16. The determination of gold in activated charcoal by use of a loose-powder technique and x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Balaes, A.M.E.

    1984-01-01

    The method of analysis described is applicable to samples of activated charcoal with a gold concentration of 15g/t and higher. The use of a loose-powder technique minimizes the time taken for the preparation of samples. A platinum internal standard is used for the correction for matrix effects and for differences that could be caused by the packing of the loose charcoal into liquid-sample cups. The precision of the method ranges from a relative standard deviation of 0,085 to 0,016 for concentrations of gold from 67 to 3800g/t respectively. The agreement between the recommended values for a set of reference samples and the values obtained by the X-ray-fluorescence method is better than 3 per cent. The overall time required for the analysis of ten samples and standards is approximately 1 hour. A detailed laboratory method and a computer programme for the calculations are given as appendices

  17. Fluorescence versus X-ray cholangiography during laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Lehrskov, Lars Lang; Larsen, Søren S; Kristensen, Billy B

    2016-01-01

    INTRODUCTION: Intraoperative fluorescent cholangiography is a novel non-invasive imaging technique to visualise the extrahepatic biliary tract during laparoscopic cholecystectomy. It has been proven feasible, fast and cost effective. Never-theless, there is only sparse data on the capacity...... of fluorescent cholangiography to visualise the biliary anatomy. METHODS: Based on a non-inferiority design, patients with complicated gallstone disease are randomised to either -intraoperative conventional X-ray cholangiography (reference group, n = 60) or intraoperative fluorescent cholangiography (n = 60......). The primary outcome is visualisation of the junction between the cystic duct, the common hepatic duct and the common bile duct. CONCLUSION: The present study may show that fluorescent cholangiography is as valid for visualisation of important structures of the extrahepatic biliary tract as conventional X...

  18. Analysis of fresco paintings by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Musilek, L.; Kopecka, I.

    2000-01-01

    In this work we present the application of X-ray fluorescence analysis (XRFA) to examine fresco paintings from the Karlstejn castle. The X-ray fluorescence apparatus built and operated in the Laboratory of Quantitative Methods in Research of Ancient Monuments was used for the purpose of fresco paintings measurements. The X-ray sources (radionuclides) generate the characteristic X-ray photons from the sample. The Si(Li) detector measures numbers and energies of photons emitted from the specimen. The energy and number of photons detected can be converted into kind and amount of measured atoms. These results give data for qualitative and quantitative analysis of samples. XRFA is relatively simple and non-destructive method. Capability of in-situ measurement is one of big advantages of this method. The radionuclide sources of exciting radiation (e.g. 55 Fe enables the excitation of elements with Z up to 23, 238 Pu is used in interval of Z from 20 to 39 etc.) were used. An Si(Li) semiconductor detector with a 5 l Dewar vessel and portable spectroscopy system enable the in situ measurement. Narrow collimation of the exciting beam makes it possible to select the measured area of fresco painting. The valuable fresco paintings from the Karlstejn castle were investigated in this way. The measurements were carried out in collaboration with the Analytical Laboratory of the State Institute for the Preservation of Historic Monuments. A suitable analysis of paintings makes it possible to detect the kind of colours and evaluate changes in the surface colour of paintings and suggest useful and timely procedures for their conservation and restoration. (author)

  19. Application of x-ray fluorescence to the measurement of additives in paper

    International Nuclear Information System (INIS)

    Buchnea, A.; McNelles, L.A.; Sinclair, A.H.; Hewitt, J.S.

    1976-01-01

    Titanium dioxide content in paper was measured by x-ray fluorescence analysis using an 55 Fe source and an x-ray proportional counter to determine the feasibility of an on-line instrument. X-ray calibration curves for 60- and 100-g/m 2 paper samples were obtained using neutron activation to measure the titanium dioxide concentration. The predictions of a simple model were in good agreement with the experimental calibration curves. The measurements and calculations were extended to investigate the effects of clay and moisture. The presence of clay has a significant effect on the x-ray fluorescence determination of the titanium dioxide concentration; however, this can be well accounted for by the model. The calculations indicated that the effect of typical moisture levels on the titanium dioxide determination was small and can be ignored. It is not possible to measure the clay content by x-ray fluorescence; however, preliminary results for the determination of calcium carbonate concentration are promising

  20. X-ray fluorescence analysis of thulium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.

    1986-01-01

    An X-ray fluorescence spectrometric method for the analysis of thulium oxide is described. For the analysis, the sample in oxalate form is mixed with boric acid binding material and pressed into a pellet over a supporting pellet of boric acid. A wavelength dispersive Philips PW 1220 X-ray fluorescence spectrometer is used for the experiments; the minimum determination limits are 0.002per cent for Ho, Lu and Y, 0.005per cent for Dy and Er and 0.01per cent for Yb. Calculations for theoretical minimum detection limits and percent standard deviation at each concentration of the standard are carried out. (author)

  1. X-ray fluorescence analysis of lutetium oxide/oxalate for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.

    1985-01-01

    An X-ray fluorescence spectrometric method for the analysis of lutetium oxide is described. The sample in the oxalate form is mixed with boric acid binding material and pressed into a pellet over supporting pellet of boric acid. A Philips PW 1220 wavelength dispersive semiautomatic X-ray fluorescence spectrometer is used for the analysis. The minimum determination limit is 0.002 percent for Y, Er and Yb and 0.005 percent for Tm. Calculations for theoretical minimum detection limits and percent standard deviations at each concentration of the standard are carried out. (author)

  2. X-ray fluorescence analysis and optical emission spectrometry of an roman mirror from Tomis, Romania

    International Nuclear Information System (INIS)

    Belc, M.; Bogoi, M.; Ionescu, D.; Guita, D.; Caiteanu, S.; Caiteanu, D.

    2000-01-01

    The miscellaneous population of Roman Empire, their diverse cultural tradition, their ability to assimilate the roman civilization spirits, had determined a permanent reassessment superimposed upon the roman contribution. Analysis was undertaken using optical emission spectrometry and non-destructive X-ray fluorescence. X-ray fluorescence analysis is a well-established method and is often used in archaeometry and other work dealing with valuable objects pertaining to the history of art and civilization. Roman mirror analysed has been found not to be made of speculum (a high tin bronze). (authors)

  3. Analysis of selected elements in tobacco by wavelength dispersive X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Martin, J.M.

    1988-01-01

    A rapid method for the determination of 16 elements in tobacco by wavelength dispersive X-ray fluorescence spectrometry has been developed. The method is accurate and precise, and requires only 9 min per sample for quantitation. Sample preparation consists of placing a portion of dried, ground tobacco in a sample cup, and pressing at 25 tons pressure to make a compressed pellet. This pellet is then automatically analyzed by X-ray fluorescence for 16 elements. The results are stored on a computer disk for future recall and report generation. The elements are: Al, Br, Ca, Cl, Cu, Fe, K, Mg, Mn, Na, P, S, Si, Sr, Ti and Zn

  4. Determination of the Mass Absorption Coefficient in Two-Layer Ti/V and V/Ti Thin Film Systems by the X-Ray Fluorescence Method

    Science.gov (United States)

    Mashin, N. I.; Chernyaeva, E. A.; Tumanova, A. N.; Gafarova, L. M.

    2016-03-01

    A new XRF procedure for the determination of the mass absorption coefficient in thin film Ti/V and V/Ti two-layer systems has been proposed. The procedure uses easy-to-make thin-film layers of sputtered titanium and vanadium on a polymer film substrate. Correction coefficients have been calculated that take into account attenuation of primary radiation of the X-ray tube, as well as attenuation of the spectral line of the bottom layer element in the top layer.

  5. X-Ray Fluorescence Spectrometry. I.- Determination of thorium in ores; Espectrometria de fluorescencia de rayos X. A.- Aplicacion a la determinacion de torio en minerales

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez Polonio, J; Crus Castillo, F. de la; Fernandez Cellini, R

    1961-07-01

    A X-ray spectrometric method has been developed for analysis of thorium in ores in the range of concentration from 0.01 to 0.5 percent ThO{sub 2}, using selenium as a internal standard. The concentration of thorium is determined in a working curve prepared by plotting the percentage of ThO{sub 2} against the ratio intensity of the Th L{alpha}{sub 1} line to Sek{sub {beta}}1 line. (Author) 17 refs.

  6. X-ray Peltier cooled detectors for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Loupilov, A.; Sokolov, A.; Gostilo, V.

    2001-01-01

    The recent results on development of X-ray Si(Li), Si-planar and CdTe p-i-n detectors cooled by Peltier coolers for fabrication of laboratory and portable XRF analysers for different applications are discussed. Low detection limits of XRF analysers are provided by increasing of detectors sensitive surface; improvement of their spectrometrical characteristics; decreasing of front-end-electronics noise level; Peltier coolers and vacuum chambers cooling modes optimization. Solution of all mentioned tasks allowed to develop Peltier cooled detectors with the following performances: (1.) Si(Li) detectors: S=20 mm 2 , thickness=3.5 mm, 175 eV (5.9 keV), 430 eV (59.6 keV); S=100 mm 2 ; thickness=4.5 mm, 270 eV (5.9 keV), 485 eV (59.6 keV). (2.) Si-planar detector: S=10 mm 2 , thickness=0.4 mm, 230 eV (5.9 keV), 460 eV (59.6 keV). (3.) CdTe p-i-n detectors: S=16 mm 2 , thickness=0.5 mm, 350 eV (5.9 keV), 585 eV (59.6 keV). S=16 mm 2 , thickness=1.2 mm, 310 eV (5.9 keV), 600 eV (59.6 keV). Advantages and disadvantages of all types of detectors for X-ray fluorescence analysis are compared. Spectra are presented. Application of different XRF analysers based on developed detectors in medicine, environmental science, industry, cryminalistics and history of art are demonstrated

  7. X-ray Peltier cooled detectors for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Loupilov, A.; Sokolov, A.; Gostilo, V.

    2000-01-01

    The recent results on development of X-ray Si(Li), Si-planar and CdTe p-i- n detectors cooled by Peltier coolers for fabrication of laboratory and portable XRF analysers for different applications are discussed. Low detection limits of XRF analysers are provided by increasing of detectors sensitive surface; improvement of their spectrometrical characteristics; decreasing of front-end-electronics noise level; Peltier coolers and vacuum chambers cooling modes optimization. Solution of all mentioned tasks allowed to develop Peltier cooled detectors with the following performances: (1) Si(Li) detectors: S = 20 mm 2 , thickness = 3.5 mm, 175 eV (5.9 keV), 430 eV (59.6 keV); S = 100 mm 2 ; thickness = 4.5 mm, 270 eV (5.9 keV), 485 eV (59,6 keV). (2) Si-planar detector: S = 10 mm 2 , thickness = 0.4 mm, 230 eV (5.9 keV), 460 eV (59.6 keV). (3) CdTe p-i-n detectors: S = 16 mm 2 , thickness 0.5 mm, 350 eV (5.9 keV), 585 eV (59.6 keV). S = 16 mm 2 , thickness = 1.2 mm, 310 eV (5.9 keV), 600 eV (59.6 keV). Advantages and disadvantages of all types of detectors for X-ray fluorescence analysis are compared. Spectra are presented. Application of different XRF analysers based on developed detectors in medicine, environmental science, industry, criminalistics and history of art are demonstrated. (author)

  8. Simulation and application of micro X-ray fluorescence based on an ellipsoidal capillary

    Science.gov (United States)

    Yang, Jing; Li, Yude; Wang, Xingyi; Zhang, Xiaoyun; Lin, Xiaoyan

    2017-06-01

    A micro X-ray fluorescence setup was presented, based on an ellipsoidal capillary and a traditional laboratorial X-ray source. Using Ray-tracing principle, we have simulated the transmission path of X-ray beam in the ellipsoidal capillary and designed the optimal parameters of the ellipsoidal capillary for the micro X-ray fluorescence setup. We demonstrate that ellipsoidal capillary is well suited as condenser for the micro X-ray fluorescence based on traditional laboratorial X-ray source. Furthermore, we obtain the 2D mapping image of the leaf blade sample by using the ellipsoidal capillary we designed.

  9. Structure determination by X-ray crystallography

    CERN Document Server

    Ladd, M F C

    1977-01-01

    Crystallography may be described as the science of the structure of materi­ als, using this word in its widest sense, and its ramifications are apparent over a broad front of current scientific endeavor. It is not surprising, therefore, to find that most universities offer some aspects of crystallography in their undergraduate courses in the physical sciences. It is the principal aim of this book to present an introduction to structure determination by X-ray crystal­ lography that is appropriate mainly to both final-year undergraduate studies in crystallography, chemistry, and chemical physics, and introductory post­ graduate work in this area of crystallography. We believe that the book will be of interest in other disciplines, such as physics, metallurgy, biochemistry, and geology, where crystallography has an important part to play. In the space of one book, it is not possible either to cover all aspects of crystallography or to treat all the subject matter completely rigorously. In particular, certain ...

  10. Calculating the X-Ray Fluorescence from the Planet Mercury Due to High-Energy Electrons

    Science.gov (United States)

    Burbine, T. H.; Trombka, J. I.; Bergstrom, P. M., Jr.; Christon, S. P.

    2005-01-01

    The least-studied terrestrial planet is Mercury due to its proximity to the Sun, which makes telescopic observations and spacecraft encounters difficult. Our lack of knowledge about Mercury should change in the near future due to the recent launching of MESSENGER, a Mercury orbiter. Another mission (BepiColombo) is currently being planned. The x-ray spectrometer on MESSENGER (and planned for BepiColombo) can characterize the elemental composition of a planetary surface by measuring emitted fluorescent x-rays. If electrons are ejected from an atom s inner shell by interaction with energetic particles such as photons, electrons, or ions, electrons from an outer shell can transfer to the inner shell. Characteristic x-rays are then emitted with energies that are the difference between the binding energy of the ion in its excited state and that of the ion in its ground state. Because each element has a unique set of energy levels, each element emits x-rays at a unique set of energies. Electrons and ions usually do not have the needed flux at high energies to cause significant x-ray fluorescence on most planetary bodies. This is not the case for Mercury where high-energy particles were detected during the Mariner 10 flybys. Mercury has an intrinsic magnetic field that deflects the solar wind, resulting in a bow shock in the solar wind and a magnetospheric cavity. Electrons and ions accelerated in the magnetosphere tend to follow its magnetic field lines and can impact the surface on Mercury s dark side Modeling has been done to determine if x-ray fluorescence resulting from the impact of high-energy electrons accelerated in Mercury's magnetosphere can be detected by MESSENGER. Our goal is to understand how much bulk chemical information can be obtained from x-ray fluorescence measurements on the dark side of Mercury.

  11. Cu,Cr and As determination in preserved woods (Eucalyptus ssp.) by X-ray fluorescence spectrometries; Determinacao de cobre, cromo e arsenio em madeira preservada (Eucalyptus sp.) pelas espectrometrias de fluorescencia de raios X

    Energy Technology Data Exchange (ETDEWEB)

    Pereira Junior, Sergio Matias

    2014-07-01

    Brazil produces around 2.2 millions of cubic meters of treated wood to meet the annual demand of railway, electric, rural and construction sectors. The most used wood species are eucalyptus (Eucalyptus ssp.) and pine (Pinus ssp.).The treated woods used for poles, sleepers, fence posts and plywoods should be according to Brazilian norms requirements. The most usual wood preservative products used in Brazil are CCA (chromated copper arsenate) and CCB (copper chromium and boron salt). The analytical methods, such as flame atomic absorption spectrometry (FAAS), plasma inductively coupled optical emission spectrometry (ICPOES) and X-ray fluorescence spectrometry (XRFS) have been used for the analytical control of those treatment processes. In this work, the eucalyptus trees (Eucalyptus ssp) samples was obtained from Minas Gerais State, Brazil, cut plantation areas. Under pressure, eucalyptus wood samples were submitted to different concentration of CCA solution reaching 3.9, 6.7, 9.1, 12.4 and 14.0 kg of CCA by m-³ sapwood retentions. Samples in cylinders and sawdust forms were obtained from treated wood samples. Copper, chromium and arsenic determination was performed using the energy dispersive X-ray fluorescence spectrometry (EDXRFS), portable X-ray fluorescence spectrometry (PXRFS), flame atomic absorption spectrometry (FAAS) and instrumental neutron activation analysis. In this work, the method of analysis, sensitivity, precision and accuracy performances of the related techniques were outlined. (author)

  12. High resolution projection X-ray microscope equipped with fluorescent X-ray analyzer and its applications

    International Nuclear Information System (INIS)

    Minami, K; Saito, Y; Kai, H; Shirota, K; Yada, K

    2009-01-01

    We have newly developed an open type fine-focus X-ray tube 'TX-510' to realize a spatial resolution of 50nm and to radiate low energy characteristic X-rays for giving high absorption contrast to images of microscopic organisms. The 'TX-510' employs a ZrO/W(100) Schottky emitter and an 'In-Lens Field Emission Gun'. The key points of the improvements are (1) reduced spherical aberration coefficient of magnetic objective lens, (2) easy and accurate focusing, (3) newly designed astigmatism compensator, (4) segmented thin film target for interchanging the target materials by electron beam shift and (5) fluorescent X-ray analysis system.

  13. The application of a microstrip gas counter to energy-dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Veloso, J.F.C.A.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    Performance characteristics of a microstrip gas counter operated as a x-ray fluorescence spectrometer are reported. Gas amplification as a function of microstrip anode-cathode voltage was measured, and the breakdown threshold voltage was determined in pure xenon. The detector temporal stability and the effect of gas purity were assessed. Energy resolution and linearity, detection efficiency, and uniformity of spatial response in the 2- to 60-keV x-ray energy range were determined from the pulse-height distributions of the fluorescence x-ray spectra induced in a variety of single- and multi-element sample materials. Energy resolution similar to conventional proportional counters was achieved at 6 keV

  14. X-ray fluorescence holography and multiple-energy x-ray holography: A critical comparison of atomic images

    International Nuclear Information System (INIS)

    Len, P.M.; Gog, T.; Fadley, C.S.; Materlik, G.

    1997-01-01

    We compare x-ray fluorescence holography (XFH) and multiple-energy x-ray holography (MEXH), two techniques that have recently been used to obtain experimental three-dimensional atomic images. For single-energy holograms, these methods are equivalent by virtue of the optical reciprocity theorem. However, XFH can only record holographic information at the characteristic fluorescence energies of the emitting species, while MEXH can record holographic information at any energy above the fluorescent edge of the emitter, thus enabling the suppression of real-twin overlaps and other aberrations and artifacts in atomic images. copyright 1997 The American Physical Society

  15. Improved fluorescent X-ray image intensifying screen

    International Nuclear Information System (INIS)

    Landeghem, W.K. van; Suys, A.R.

    1981-01-01

    An X-ray image intensifying screen is described, which includes at least one fluorescent layer comprising phosphor particles dispersed in a binder and on top of such layer a protective layer containing a crosslinked polymer mass obtained by an acid-catalyzed reaction of a polymer or mixture of polymers containing reactive hydrogen atoms and a cross-linking agent, the cross-linking agent being an organic compound containing a plurality of etherified N-methylol groups. Examples are given of appropriate polymers and cross-linking agents. (author)

  16. X-ray fluorescence analysis of welding fume particles

    International Nuclear Information System (INIS)

    Carsey, T.P.

    1982-01-01

    A commercial standard filter set and two laboratory-made standard filter sets are compared via the analysis of generated welding fume samples by X-ray fluorescence. The latter standards are made by (1) hydrophobic-edge membrane filters spiked with prepared metal ion solutions, and (2) filters through which a dispersion of metal oxide powder in isopropanol has been drawn. The results are presented in table form. Precision (Pre) is the relative standard deviation of the six samples. Four main conclusions are enumerated

  17. Sensitometric curve of radiographic films by X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, E.A.S., E-mail: elicardo.goncalves@ifrj.edu.br [Instituto Federal do Rio de Janeiro (IFRJ), RJ (Brazil); Oliveira, D.F.; Anjos, M.J. dos; Oliveira, L.F. de [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Lopes, R.T. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Radiographic film exposure is traditionally measured by the transmittance of a beam of light through the film. There are many mathematical and computational models to characterize the curve behavior and its properties, but almost none of them considers the limitations caused by the equipment used. As long as exposure in film increases, light intensity measured after the film decreases in a way that from a certain exposure, light could not be distinguished from any kind of noise. This work aims to propose x-ray fluorescence as a solution for better measure high exposed films and show how it could be modeled mathematically. (author)

  18. Quantification procedures in micro X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kanngiesser, Birgit

    2003-01-01

    For the quantification in micro X-ray fluorescence analysis standardfree quantification procedures have become especially important. An introduction to the basic concepts of these quantification procedures is given, followed by a short survey of the procedures which are available now and what kind of experimental situations and analytical problems are addressed. The last point is extended by the description of an own development for the fundamental parameter method, which renders the inclusion of nonparallel beam geometries possible. Finally, open problems for the quantification procedures are discussed

  19. Analysis of kiwi fruit (Accented deliciosa) by energy dispersive X-ray fluorescence spectra

    International Nuclear Information System (INIS)

    Oliveira, Ana Claudia S.; Oliveira, Marcia L. de; Silva, Lucia C.A.S.; Arthur, Valter; Almeida, Eduardo

    2011-01-01

    The search for a healthy life has led consumers to eat fruits and vegetables in place of manufactured products, however, the demand for minimally processed products has evolved rapidly. The kiwi has at least eight nutrients beneficial to health: calcium, magnesium, manganese, phosphorus, iron, potassium, sodium and has also high vitamin C, which has wide acceptance in consumer markets. Energy dispersive spectroscopy X-ray (EDX) is the analytical technique used for elemental analysis or chemical characterization of a sample. It is a variant of fluorescence spectroscopy X-ray based on the sample through an investigation of interactions between electromagnetic radiation and matter, analyzing X-rays emitted by matter in response to being struck by charged particles. The aim of this study were to determine potassium, calcium, iron and bromine (K, Ca, Fe and Br, respectively) present in kiwifruit using the technique of fluorescence X-ray energy dispersive (EDXRF). Kiwifruit were peeled, washed and cut into slices and freeze-dried. After drying the sample was held digestion and subsequent reading of the same equipment in the X-ray fluorescence energy dispersive (EDXRF). The results indicated that the contents of potassium, calcium, iron and bromine are present in kiwifruit as expected when compared to Brazilian Table of Food Composition. (author)

  20. Analysis of River sediments from the Tigre river (Venezuela) by radioisotope excited x-ray fluorescence

    International Nuclear Information System (INIS)

    LaBrecque, J.J.; Rosales, P.A.; Schorin, H.

    1985-01-01

    This paper describes qualitative elemental scans by both energy dispersive (radioisotope excited) and conventional wavelength dispersive x-ray fluorescence of different grain size fractions of river sediments. An internal standard thin-film technique was used. The precision of Rb, Sr, Y and Zr determination for SY-3 standard reference rock and one real sample for five independently prepared samples is demonstrated

  1. Confirmation of molecular formulas of metallic complexes through X-ray fluorescence quantitative analysis

    International Nuclear Information System (INIS)

    Filgueiras, C.A.L.; Marques, E.V.; Machado, R.M.

    1984-01-01

    X-ray fluorescence spectrophotometry was employed to determined the metal content in a series of five transition element complexes (Mn, Ti, Zn, V). The results confirmed the molecular formulas of these complexes, already proposed on the basis of elemental microanalysis, solution condutimetry and other analytical methods. (C.L.B.) [pt

  2. SAVLOC, computer program for automatic control and analysis of X-ray fluorescence experiments

    Science.gov (United States)

    Leonard, R. F.

    1977-01-01

    A program for a PDP-15 computer is presented which provides for control and analysis of trace element determinations by using X-ray fluorescence. The program simultaneously handles data accumulation for one sample and analysis of data from previous samples. Data accumulation consists of sample changing, timing, and data storage. Analysis requires the locating of peaks in X-ray spectra, determination of intensities of peaks, identification of origins of peaks, and determination of a real density of the element responsible for each peak. The program may be run in either a manual (supervised) mode or an automatic (unsupervised) mode.

  3. Total-reflection X-ray fluorescence analysis of Austrian wine

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, X. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Kregsamer, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Wobrauschek, P. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria); Streli, C. [Atominstitut der Osterreichischen Universitaeten, 1020 Vienna (Austria)]. E-mail: streli@ati.ac.at

    2006-11-15

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 {mu}l of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines.

  4. Total-reflection X-ray fluorescence analysis of Austrian wine

    International Nuclear Information System (INIS)

    Gruber, X.; Kregsamer, P.; Wobrauschek, P.; Streli, C.

    2006-01-01

    The concentration of major, minor and trace elements in Austrian wine was determined by total-reflection X-ray fluorescence using gallium as internal standard. A multi-elemental analysis was possible by pipetting 6 μl of wine directly on the reflector and drying. Total-reflection X-ray fluorescence analysis was performed with Atomika EXTRA II A (Cameca) X-rays from a Mo tube with a high-energy cut-off at 20 keV in total-reflection geometry. The results showed that it was possible to identify only by the elemental analysis as fingerprint the vineyards and year of vintage among 11 different wines

  5. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop LUNA, a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for mineralogical analysis of regolith, rock...

  6. X-Ray Diffraction and Fluorescence Instrument for Mineralogical Analysis at the Lunar Surface, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact and lightweight X-Ray Diffraction (XRD) / X-Ray Fluorescence (XRF) instrument for analysis of mineralogical composition of regolith,...

  7. A low power x-ray tube for use in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Kataria, S.K.; Govil, Rekha; Lal, M.

    1980-01-01

    A low power X-ray tube with thin molybdenum transmission target for use in energy dispersive X-ray fluorescence (ENDXRF) element analysis has been indigenously built, along with its power supply. The X-ray tube has been in operation since August 1979, and it has been operated upto maximum target voltage of 35 KV and tube current upto 200 μA which is more than sufficient for trace element analysis. This X-ray tube has been used alongwith the indigenously built Si(Li) detector X-ray spectrometer with an energy resolution of 200 eV at 5.9 Kev MnKsub(α) X-ray peak for ENDXRF analysis. A simple procedure of calibration has been developed for thin samples based on the cellulose diluted, thin multielement standard pellets. Analytical sensitivities of the order of a few p.p.m. have been obtained with the experimental setup for elements with 20 < = Z < = 38 and 60 < = Z < = 90. A number of X-ray spectra for samples of environmental, biological, agricultural, industrial and metallurgical interest are presented to demonstrate the salient features of the experimental sep up. (auth.)

  8. Preparation of tissue samples for X-ray fluorescence microscopy

    International Nuclear Information System (INIS)

    Chwiej, Joanna; Szczerbowska-Boruchowska, Magdalena; Lankosz, Marek; Wojcik, Slawomir; Falkenberg, Gerald; Stegowski, Zdzislaw; Setkowicz, Zuzanna

    2005-01-01

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain

  9. Preparation of tissue samples for X-ray fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chwiej, Joanna [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)]. E-mail: jchwiej@novell.ftj.agh.edu.pl; Szczerbowska-Boruchowska, Magdalena [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Lankosz, Marek [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Wojcik, Slawomir [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Falkenberg, Gerald [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron, Notkestr. 85, Hamburg (Germany); Stegowski, Zdzislaw [Faculty of Physics and Applied Computer Science, AGH-University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Setkowicz, Zuzanna [Department of Neuroanatomy, Institute of Zoology, Jagiellonian University, Ingardena 6, 30-060 Cracow (Poland)

    2005-12-15

    As is well-known, trace elements, especially metals, play an important role in the pathogenesis of many disorders. The topographic and quantitative elemental analysis of pathologically changed tissues may shed some new light on processes leading to the degeneration of cells in the case of selected diseases. An ideal and powerful tool for such purpose is the Synchrotron Microbeam X-ray Fluorescence technique. It enables the carrying out of investigations of the elemental composition of tissues even at the single cell level. The tissue samples for histopathological investigations are routinely fixed and embedded in paraffin. The authors try to verify the usefulness of such prepared tissue sections for elemental analysis with the use of X-ray fluorescence microscopy. Studies were performed on rat brain samples. Changes in elemental composition caused by fixation in formalin or paraformaldehyde and embedding in paraffin were examined. Measurements were carried out at the bending magnet beamline L of the Hamburger Synchrotronstrahlungslabor HASYLAB in Hamburg. The decrease in mass per unit area of K, Br and the increase in P, S, Fe, Cu and Zn in the tissue were observed as a result of the fixation. For the samples embedded in paraffin, a lower level of most elements was observed. Additionally, for these samples, changes in the composition of some elements were not uniform for different analyzed areas of rat brain.

  10. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, U.E.A. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: ursula.fittschen@chemie.uni-hamburg.de; Meirer, F. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: fmeirer@ati.ac.at; Streli, C. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: streli@ati.ac.at; Wobrauschek, P. [Atominstitut, Vienna University of Technology, Stadionallee 2, 1020 Wien (Austria)], E-mail: wobi@ati.ac.at; Thiele, J. [Department of Chemistry, University of Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)], E-mail: Julian.Thiele@gmx.de; Falkenberg, G. [Hamburger Synchrotronstrahlungslabor at Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22603 Hamburg (Germany)], E-mail: falkenbe@mail.desy.de; Pepponi, G. [ITC-irst, Via Sommarive 18, 38050 Povo (Trento) (Italy)], E-mail: pepponi@itc.it

    2008-12-15

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 {mu}m, 8.0-2.0 {mu}m, 2.0-0.13 {mu}m 0.13-0.015 {mu}m (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 {mu}m, 1-2 {mu}m, 2-4 {mu}m, 4-8 {mu}m, 8-16 {mu}m. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in

  11. Characterization of atmospheric aerosols using Synchroton radiation total reflection X-ray fluorescence and Fe K-edge total reflection X-ray fluorescence-X-ray absorption near-edge structure

    International Nuclear Information System (INIS)

    Fittschen, U.E.A.; Meirer, F.; Streli, C.; Wobrauschek, P.; Thiele, J.; Falkenberg, G.; Pepponi, G.

    2008-01-01

    In this study a new procedure using Synchrotron total reflection X-ray fluorescence (SR-TXRF) to characterize elemental amounts in atmospheric aerosols down to particle sizes of 0.015 um is presented. The procedure was thoroughly evaluated regarding bounce off effects and blank values. Additionally the potential of total reflection X-ray fluorescence-X-ray absorption near edge structure (SR-TXRF-XANES) for speciation of FeII/III down to amounts of 34 pg in aerosols which were collected for 1 h is shown. The aerosols were collected in the city of Hamburg with a low pressure Berner impactor on Si carriers covered with silicone over time periods of 60 and 20 min each. The particles were collected in four and ten size fractions of 10.0-8.0 μm, 8.0-2.0 μm, 2.0-0.13 μm 0.13-0.015 μm (aerodynamic particle size) and 15-30 nm, 30-60 nm, 60-130 nm, 130-250 nm, 250-500 nm, 0.5-1 μm, 1-2 μm, 2-4 μm, 4-8 μm, 8-16 μm. Prior to the sampling 'bounce off' effects on Silicone and Vaseline coated Si carriers were studied with total reflection X-ray fluorescence. According to the results silicone coated carriers were chosen for the analysis. Additionally, blank levels originating from the sampling device and the calibration procedure were studied. Blank levels of Fe corresponded to 1-10% of Fe in the aerosol samples. Blank levels stemming from the internal standard were found to be negligible. The results from the Synchroton radiation total reflection X-ray fluorescence analysis of the aerosols showed that 20 min of sampling time gave still enough sample material for elemental determination of most elements. For the determination of the oxidation state of Fe in the aerosols different Fe salts were prepared as a reference from suspensions in isopropanol. The results from the Fe K-edge Synchroton radiation total reflection X-ray fluorescence-X-ray absorption near-edge structure analysis of the aerosol samples showed that mainly Fe(III) was present in all particle size fractions

  12. Romanian medieval earring analysis by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Therese, Laurent; Guillot, Philippe; Muja, Cristina

    2011-01-01

    Full text: Several instrumental techniques of elemental analysis are now used for the characterization of archaeological materials. The combination between archaeological and analytical information can provide significant knowledge on the constituting material origin, heritage authentication and restoration, provenance, migration, social interaction and exchange. Surface mapping techniques such as X-Ray Fluorescence have become a powerful tool for obtaining qualitative and semi-quantitative information about the chemical composition of cultural heritage materials, including metallic archaeological objects. In this study, the material comes from the Middle Age cemetery of Feldioara (Romania). The excavation of the site located between the evangelical church and the parsonage led to the discovery of several funeral artifacts in 18 graves among a total of 127 excavated. Even if the inventory was quite poor, some of the objects helped in establishing the chronology. Six anonymous Hungarian denarii (silver coins) were attributed to Geza II (1141-1161) and Stefan III (1162-1172), placing the cemetery in the second half of the XII century. This period was also confirmed by three loop shaped earrings with the end in 'S' form (one small and two large earrings). The small earring was found during the excavation in grave number 86, while the two others were discovered together in grave number 113. The anthropological study shown that skeletons excavated from graves 86 and 113 belonged respectively to a child (1 individual, medium level preservation, 9 months +/- 3 months) and to an adult (1 individual). In this work, elemental mapping were obtained by X-ray fluorescence (XRF) technique from Jobin Yvon Horiba XGT-5000 instrument offering detailed elemental images with a spatial resolution of 100μm. The analysis revealed that the earrings were composed of copper, zinc and tin as major elements. Minor elements were also determined. The comparison between the two large earrings

  13. Romanian medieval earring analysis by X-ray fluorescence technique

    Energy Technology Data Exchange (ETDEWEB)

    Therese, Laurent; Guillot, Philippe, E-mail: philippe.guillot@univ-jfc.fr [Laboratoire Diagnostics des Plasmas, CUFR J.F.C, Albi (France); Muja, Cristina [Laboratoire Diagnostics des Plasmas, CUFR J.F.C, Albi (France); Faculty of Biology, University of Bucharest (Romania); Vasile Parvan Institute of Archaeology, Bucharest, (Romania)

    2011-07-01

    Full text: Several instrumental techniques of elemental analysis are now used for the characterization of archaeological materials. The combination between archaeological and analytical information can provide significant knowledge on the constituting material origin, heritage authentication and restoration, provenance, migration, social interaction and exchange. Surface mapping techniques such as X-Ray Fluorescence have become a powerful tool for obtaining qualitative and semi-quantitative information about the chemical composition of cultural heritage materials, including metallic archaeological objects. In this study, the material comes from the Middle Age cemetery of Feldioara (Romania). The excavation of the site located between the evangelical church and the parsonage led to the discovery of several funeral artifacts in 18 graves among a total of 127 excavated. Even if the inventory was quite poor, some of the objects helped in establishing the chronology. Six anonymous Hungarian denarii (silver coins) were attributed to Geza II (1141-1161) and Stefan III (1162-1172), placing the cemetery in the second half of the XII century. This period was also confirmed by three loop shaped earrings with the end in 'S' form (one small and two large earrings). The small earring was found during the excavation in grave number 86, while the two others were discovered together in grave number 113. The anthropological study shown that skeletons excavated from graves 86 and 113 belonged respectively to a child (1 individual, medium level preservation, 9 months +/- 3 months) and to an adult (1 individual). In this work, elemental mapping were obtained by X-ray fluorescence (XRF) technique from Jobin Yvon Horiba XGT-5000 instrument offering detailed elemental images with a spatial resolution of 100{mu}m. The analysis revealed that the earrings were composed of copper, zinc and tin as major elements. Minor elements were also determined. The comparison between the two

  14. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    Science.gov (United States)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

  15. Study of the elemental composition of Chenopodium Quinoa Willd by fast neutron activation analysis and X ray fluorescence analysis

    International Nuclear Information System (INIS)

    Soto Moran, R.L.; Szegedi, S.; Llopiz, J.L.

    1996-01-01

    By means of x-ray fluorescence and fast neutron activation analysis the nitrogen content has been determined in samples of roots, stems, leaf, flowers and grains from Quinua (Chenopodium Quinoa Willd), which was previously treated with fertilizer

  16. Laboratory evaluation of a field-portable sealed source X-ray fluorescence spectrometer for determination of metals in air filter samples.

    Science.gov (United States)

    Lawryk, Nicholas J; Feng, H Amy; Chen, Bean T

    2009-07-01

    Recent advances in field-portable X-ray fluorescence (FP XRF) spectrometer technology have made it a potentially valuable screening tool for the industrial hygienist to estimate worker exposures to airborne metals. Although recent studies have shown that FP XRF technology may be better suited for qualitative or semiquantitative analysis of airborne lead in the workplace, these studies have not extensively addressed its ability to measure other elements. This study involved a laboratory-based evaluation of a representative model FP XRF spectrometer to measure elements commonly encountered in workplace settings that may be collected on air sample filter media, including chromium, copper, iron, manganese, nickel, lead, and zinc. The evaluation included assessments of (1) response intensity with respect to location on the probe window, (2) limits of detection for five different filter media, (3) limits of detection as a function of analysis time, and (4) bias, precision, and accuracy estimates. Teflon, polyvinyl chloride, polypropylene, and mixed cellulose ester filter media all had similarly low limits of detection for the set of elements examined. Limits of detection, bias, and precision generally improved with increasing analysis time. Bias, precision, and accuracy estimates generally improved with increasing element concentration. Accuracy estimates met the National Institute for Occupational Safety and Health criterion for nearly all the element and concentration combinations. Based on these results, FP XRF spectrometry shows potential to be useful in the assessment of worker inhalation exposures to other metals in addition to lead.

  17. Seasonal determination of trace and ultra-trace content in Macrocystis pyrifera from San Jorge Gulf (Patagonia) by Total Reflection X-ray Fluorescence

    Science.gov (United States)

    Salomone, Vanesa N.; Riera, Marina; Cerchietti, Luciana; Custo, Graciela; Muniain, Claudia

    2017-05-01

    Seaweed have a great capacity to accumulate heavy metals in their tissues. The chemical characterization of seaweed is important due to their use in environmental monitoring and human or animal food. The aim of the present study was to evaluate the multi-elemental composition of seaweed from San Jorge Gulf (Patagonia, Argentina) by Total Reflection X-ray Fluorescence (TXRF). The elements As, Br, Cu, Cr, Fe, Mn, Ni, Pb, Rb, Sr, V and Zn were seasonally analyzed and quantified in blades of Macrocystis pyrifera. TXRF showed to be a suitable technique for simultaneous multi-element analysis in this kind of samples. The results revealed seasonal variations in the chemical content for some elements; arsenic content was maximum in summer and autumn, iron concentration increased to the winter and zinc concentration was maximum in autumn. The sum of principal micronutrients (Fe + Zn + Mn + Cu) varied between 114 and 171 mg k- 1 g dw. The total As concentration ranged between 36 and 66 mg kg- 1. Lead, nickel and copper were not detected.

  18. The potential for portable X-ray fluorescence determination of soil copper at ancient metallurgy sites, and considerations beyond measurements of total concentrations.

    Science.gov (United States)

    Tighe, M; Rogan, G; Wilson, S C; Grave, P; Kealhofer, L; Yukongdi, P

    2018-01-15

    Copper (Cu) at ancient metallurgy sites represents the earliest instance of anthropogenically generated metal pollution. Such sites are spread across a wide range of environments from Eurasia to South America, and provide a unique opportunity to investigate the past and present extent and impact of metalworking contamination. Establishing the concentration and extent of soil Cu at archaeometallurgy sites can enhance archaeological interpretations of site use but can also, more fundamentally, provide an initial indication of contamination risk from such sites. Systematic evaluations of total soil Cu concentrations at ancient metalworking sites have not been conducted, due in part to the limitations of conventional laboratory-based protocols. In this paper, we first review what is known about Cu soil concentrations at ancient metallurgy sites. We then assess the benefits and challenges of portable X-ray fluorescence spectrometry (pXRF) as an alternative, rapid technique for the assessment of background and contaminant levels of Cu in soils. We conclude that pXRF is an effective tool for identifying potential contamination. Finally, we provide an overview of some major considerations beyond total Cu concentrations, such as bioavailability assessments, that will need to be considered at such sites to move toward a complete assessment of environmental and human risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The determination of lead, zinc, and magnesium in dolomite and its benefication products by use of x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Jacobs, J.J.

    1985-01-01

    An investigation was undertaken on the development of fast, simple, and accurate methods of analysis for lead and zinc in tailings and middlings from dolomite, and for lead, zinc, and magnesium in concentrates obtained from dolomite. A pressed-powder technique and X-ray-fluorescence spectrometry (XRFS) were used. Good agreement was found between the XRFS values for lead and zinc in low concentrations and the values obtained by other techniques of analysis when the calibration for the XRFS method was effected by the use of synthetic standards comprising lead and zinc oxides in a dolomite matrix. For high concentrations of the analytes, all the oxides and sulphides of lead and zinc in the samples had to be converted to the sulphate form, and a matrix correction had to be applied to the assigned values of the oxide calibration standards. The lower limits of detection for lead, zinc, and magnesium were 0,004, 0,003, and 0,18 per cent respectively. The recommended methods are detailed in two appendices

  20. Feasibility study for the in vivo measurement of lead in bone using L-x-ray fluorescence

    International Nuclear Information System (INIS)

    Wielopolski, L.; Slatkin, D.N.; Vartsky, D.; Ellis, K.J.; Cohn, S.H.

    1980-01-01

    Lead deposits in bone were detected by x-ray fluorescence using x-rays from either a 125 I or a 109 Cd source. Measurements were taken from tibia in intact human legs, post-mortem. On the basis of preliminary measurements, it was concluded that an exposure of one rad is adequate for determination of lead in bone. Both the advantages and the disadvantages of L-x-rays, used in the technique developed for this study, are compared with those of K-x-rays

  1. Analysis of Precious Stones Deposited in Various Rock Samples of Mogok Region by energy dispersive X-ray Fluorescence Spectrometry

    International Nuclear Information System (INIS)

    Kyi Kyi San; Soe Lwin; Win Win Thar; Sein Htoon

    2004-06-01

    The analysis of precious stones deposited in various rock samples of Mogok region were investigated by the energy dispersive x-ray fluorescence technique. The x-ray machine with Rh target was used to excite the characteristic x-ray from the sample. X-rays emitted from the sample were measured by a high resolution, cooled Si (Li) detector. The calibration was made by the measurement of minerals which composed in each kind of precious stones. The kind of precious stone deposited in the rocks sample was determined by the measurement of minerals from the rock samples compared with those obtained from each kind of precious stones

  2. X-ray fluorescence analysis of terbium oxide for rare earth impurities

    International Nuclear Information System (INIS)

    Chandola, L.C.; Machado, I.J.; Mohile, A.N.

    1975-01-01

    A method for the determination of Sm 2 O 3 , Eu 2 O 3 , Gd 2 O 3 , Dy 2 O 3 , Ho 2 O 3 and Y 2 O 3 in terbium oxide is described. The sample is converted to terbium oxalate, mixed with boric acid binder in the ratio 2:1, pelleted at a pressure of 20 tons over a boric acid backing pellet and irradiated with x-rays from a tungsten tube operated by Philips PW 1140 generator. The secondary x-rays thus generated are analysed by a LiF (200) crystal in Philips PW 1220 x-ray fluorescence spectrometer using suitable detectors. The minimum determination limit (MDL) is 0.01% for all rare earth oxides determined except for Y 2 O 3 for which it is 0.005%. (author)

  3. Monitoring the mass of UF6 gas and uranium deposits in aluminium pipes using X-ray fluorescence and X-ray transmission gauges

    International Nuclear Information System (INIS)

    Packer, T.W.; Smith, S.M.

    1984-12-01

    In order to determine the enrichment of UF 6 gas in centrifuge plant pipework it is necessary to measure the mass of the gas (pressure) and the mass per unit area of any uranium deposited on the pipe. This paper shows that it is possible to determine the pressure of the UF 6 gas in pipes 120 mm in diameter using an energy-dispersive X-ray fluorescence spectrometer. Results are also given of transmission measurements made using a low power X-ray generator operated at two different applied voltages. A method of using the two measurements to determine the mass per unit area of deposited uranium is described. (author)

  4. MCNP calculation for calibration curve of X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Tan Chunming; Wu Zhifang; Guo Xiaojing; Xing Guilai; Wang Zhentao

    2011-01-01

    Due to the compositional variation of the sample, linear relationship between the element concentration and fluorescent intensity will not be well maintained in most X-ray fluorescence analysis. To overcome this, we use MCNP program to simulate fluorescent intensity of Fe (0∼100% concentration range) within binary mixture of Cr and O which represent typical strong absorption and weak absorption conditions respectively. The theoretic calculation shows that the relationship can be described as a curve determined by parameter p and value of p can be obtained with given absorption coefficient of substrate elements and element under detection. MCNP simulation results are consistent with theoretic calculation. Our research reveals that MCNP program can calculate the Calibration Curve of X-ray fluorescence very well. (authors)

  5. An X-ray fluorescence method for the determination of small quantities el elements collected on filters; Determinacion de pequenas concentraciones de elementos en filtros por espectrometria de fluorescencia de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Guerra, J. P.; Bayon, A.

    1981-07-01

    An X-ray fluorescence method for the determination of As, Ba, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se, U, V and Zn collected on P.V.C. filters in concentration ranges from 0,6 to 1000{mu}g, depending on the element, is described. A sequential automatic spectrometer with a chromium tube is used for tho Ba determination, while As, Hg, Pb, Se and U are bottler determined with a molybdenum one. For the rest of the elements a tungsten target is preferred. The interferences between AsK{sup {alpha}}{sub 1},2- PbL{sup {alpha}}{sub 1},2 and CrK{sup {alpha}}{sub 1},2-Vk{beta}{sub 1},3 lines are corrected by applying specific coefficients. The radial variation of the primary X-ray beam intensity on the irradiated surface has been specially studied with chromium, gold, molybdenum and tungsten tubes. For that purpose different x-ray wavelengths in the range 9,89 A to 0,56 A have been selected. The curves obtained show a rather high heterogeneity for the excitation source. This conclusion implies the need for an homogeneous distribution of elements on the filter. (Author) 7 refs.

  6. Analysis of siliceous geologic materials by energy-dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Roca, M.; Bayon, A.

    1987-01-01

    The determination of the elements Al, Si, K, Ca, Ti, Cr, Mn and Fe in siliceous geologic samples by energy-dispersive X-ray fluorescence is investigated using the most adequate excitation conditions: direct excitation mode (rhodium anode X-ray tube) for the former two elements, and the secondary targets titanium for K and Ca, and germanium for Ti, Cr, Mn and Fe. For the correction of matrix effects the use of ratio methods has been tested. Procedure files have been defined allowing the automatic simultaneous acquisition and processing of spectra. (author)

  7. A comparative study on total reflection X-ray fluorescence determination of low atomic number elements in air, helium and vacuum atmospheres using different excitation sources

    Science.gov (United States)

    Misra, N. L.; Kanrar, Buddhadev; Aggarwal, S. K.; Wobrauschek, Peter; Rauwolf, M.; Streli, Christina

    2014-09-01

    A comparison of trace element determinations of low atomic number (Z) elements Na, Mg, Al, P, K and Ca in air, helium and vacuum atmospheres using W Lβ1, Mo Kα and Cr Kα excitations has been made. For Mo Kα and W Lβ1 excitations a Si (Li) detector with beryllium window was used and measurements were performed in air and helium atmospheres. For Cr Kα excitation, a Si (Li) detector with an ultra thin polymer window (UTW) was used and measurements were made in vacuum and air atmospheres. The sensitivities of the elemental X-ray lines were determined using TXRF spectra of standard solutions and processing them by IAEA QXAS program. The elemental concentrations of the elements in other solutions were determined using their TXRF spectra and pre-determined sensitivity values. The study suggests that, using the above experimental set up, Mo Kα excitation is not suited for trace determination of low atomic number element. Excitation by WLβ1 and helium atmosphere, the spectrometer can be used for the determination of elements with Z = 15 (P) and above with fairly good detection limits whereas Cr Kα excitation with ultra thin polymer window and vacuum atmosphere is good for the elements having Z = 11 (Na) and above. The detection limits using this set up vary from 7048 pg for Na to 83 pg for Ti.

  8. Automating X-ray Fluorescence Analysis for Rapid Astrobiology Surveys.

    Science.gov (United States)

    Thompson, David R; Flannery, David T; Lanka, Ravi; Allwood, Abigail C; Bue, Brian D; Clark, Benton C; Elam, W Timothy; Estlin, Tara A; Hodyss, Robert P; Hurowitz, Joel A; Liu, Yang; Wade, Lawrence A

    2015-11-01

    A new generation of planetary rover instruments, such as PIXL (Planetary Instrument for X-ray Lithochemistry) and SHERLOC (Scanning Habitable Environments with Raman Luminescence for Organics and Chemicals) selected for the Mars 2020 mission rover payload, aim to map mineralogical and elemental composition in situ at microscopic scales. These instruments will produce large spectral cubes with thousands of channels acquired over thousands of spatial locations, a large potential science yield limited mainly by the time required to acquire a measurement after placement. A secondary bottleneck also faces mission planners after downlink; analysts must interpret the complex data products quickly to inform tactical planning for the next command cycle. This study demonstrates operational approaches to overcome these bottlenecks by specialized early-stage science data processing. Onboard, simple real-time systems can perform a basic compositional assessment, recognizing specific features of interest and optimizing sensor integration time to characterize anomalies. On the ground, statistically motivated visualization can make raw uncalibrated data products more interpretable for tactical decision making. Techniques such as manifold dimensionality reduction can help operators comprehend large databases at a glance, identifying trends and anomalies in data. These onboard and ground-side analyses can complement a quantitative interpretation. We evaluate system performance for the case study of PIXL, an X-ray fluorescence spectrometer. Experiments on three representative samples demonstrate improved methods for onboard and ground-side automation and illustrate new astrobiological science capabilities unavailable in previous planetary instruments. Dimensionality reduction-Planetary science-Visualization.

  9. X-ray fluorescence spectrometry and related techniques an introduction

    CERN Document Server

    Margui, Eva

    2013-01-01

    X-ray fluorescence spectrometry (XRF) is a well-established analytical technique for qualitative and quantitative elemental analysis of a wide variety of routine quality control and research samples. Among its many desirable features, it delivers true multi-element character analysis, acceptable speed and economy, easy of automation, and the capacity to analyze solid samples. This remarkable contribution to this field provides a comprehensive and up-to-date account of basic principles, recent developments, instrumentation, sample preparation procedures, and applications of XRF analysis. If you are a professional in materials science, analytic chemistry, or physics, you will benefit from not only the review of basics, but also the newly developed technologies with XRF. Those recent technological advances, including the design of low-power micro- focus tubes and novel X-ray optics and detectors, have made it possible to extend XRF to the analysis of low-Z elements and to obtain 2D or 3D information on a microme...

  10. Dosage of silicon in a soluble silicate using an x-ray-fluorescence radioisotopic method

    International Nuclear Information System (INIS)

    Wasilewska, M.; Robert, A.

    1969-01-01

    A description is given of a spectrometer for X ray fluorescence analysis having a radio active excitation source. It has been applied to the analysis of the silicon contained in an industrial soluble silicate. A theoretical study has been made for this analysis of the operational conditions such as: the effect of the particle size, the dilution of the sample, the sensitivity as a function of the X ray excitation energy. It is possible to obtain a relative accuracy of 0,87 per cent for the silicon determination, for one standard deviation. A comparison is made of the sensitivity obtained using this apparatus for the Si determination with that which can be obtained using a conventional apparatus fitted with an X ray tube. (author) [fr

  11. Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation

    Science.gov (United States)

    Takeda, Tohoru; Yu, Quanwen; Yashiro, Toru; Yuasa, Tetsuya; Hasegawa, Yasuo; Itai, Yuji; Akatsuka, Takao

    1999-09-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT system consists of a silicon (111) channel cut monochromator, an x-ray slit and a collimator for fluorescent x ray detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the fluorescent K(alpha) line, incident monochromatic x-ray was set at 37 keV. The FXCT clearly imaged a human thyroid gland and iodine content was estimated quantitatively. In a case of hyperthyroidism, the two-dimensional distribution of iodine content was not uniform, and thyroid cancer had a small amount of iodine. FXCT can be used to detect iodine within thyroid gland quantitatively and to delineate its distribution.

  12. Simulation and application of micro X-ray fluorescence based on an ellipsoidal capillary

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jing; Li, Yude; Wang, Xingyi; Zhang, Xiaoyun; Lin, Xiaoyan, E-mail: yangjing_928@126.com

    2017-06-15

    Highlights: • A micro X-ray fluorescence setup based on an ellipsoidal capillary was presented. • The optimal parameters of ellipsoidal capillary were designed. • The 2D mapping image of biological sample was obtained. - Abstract: A micro X-ray fluorescence setup was presented, based on an ellipsoidal capillary and a traditional laboratorial X-ray source. Using Ray-tracing principle, we have simulated the transmission path of X-ray beam in the ellipsoidal capillary and designed the optimal parameters of the ellipsoidal capillary for the micro X-ray fluorescence setup. We demonstrate that ellipsoidal capillary is well suited as condenser for the micro X-ray fluorescence based on traditional laboratorial X-ray source. Furthermore, we obtain the 2D mapping image of the leaf blade sample by using the ellipsoidal capillary we designed.

  13. Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Gailhanou, M.; Walter, P.; Schyns, E.; Marchis, F.; Thompson, K.; Bristow, T.

    2016-01-01

    Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100µm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

  14. X-ray fluorescent scanning of the thyroid

    International Nuclear Information System (INIS)

    Jonckheer, M.H.; Deconinck, F.

    1983-01-01

    The main emphasis of the technical chapters of this monograph lies on the aspects which are of direct importance to thyroid scanning: the general principles of X-ray fluorescence, the choice and characteristics of appropriate sources and detectors, a stationary system, quantification problems, and the pitfalls in the interpretation of the intrathyroidal iodine imaging and quantification. The clinical part of the monograph consists of chapters on the role of stable iodine and the thyroid function, on endemic non-toxic goiter, on hyperthyroidism as a result of iodine overload, on feasibility of dynamic studies, on stable iodine stores in thyroiditis, and on a general review of the clinical usefulness of XRF in thyroid disease. (Auth.)

  15. X-ray fluorescence in research on Czech cultural monuments

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Kopecka, I.; Musilek, L.

    2004-01-01

    Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work

  16. Environmental studies in Khartoum area using x-ray fluorescence

    International Nuclear Information System (INIS)

    Abdel Elmagid, Suliman Alamin

    1996-06-01

    In the present work an attempt has been made for the analysis of some soil, plant, sediments and fish samples of relevance to environmental pollution in Khartoum area. These samples have been collected from different places in residential areas, so as to cover industrial areas, agricultural and residential areas, as well as Tuti Island as control area. Special attention has been dedicated to the analysis of lead concentrations resulting from automobile-emissions in soils and to other toxic metals such as Cr in some industries. The samples were analysed by x-ray fluorescence (XRF) technique. The results obtained using XRF measurements and computer software called QXAS for data analysis. The concentrations of lead and some heavy metals such as Cr in soils from certain locations were alarming and may create pollution problems in the near future. The results obtained from different countries. The results are generally lower than the international limits. (Author)

  17. Handbook of practical X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Beckhoff, B.; Wedell, R.; Wolff, H.

    2006-01-01

    X-ray fluorescence analysis (XRF) is a reliable multi-elemental and nondestructive analytical method widely used in research and industrial applications. This practical handbook provides self-contained modules featuring XRF instrumentation, quantification methods, and most of the current applications. The broad spectrum of topics is due to the efforts of a large number of authors from a variety of different types of institutions such as universities, research institutes, and companies. The book gives a survey of the theoretical fundamentals, analytical instrumentation, software for data processing, various excitation regimes including gracing incidents and microfocus measurements, quantitative analysis, applications in routine and micro analysis, mineralogy, biology, medicine, criminal investigations, archeology, metallurgy, abrasion, microelectronics, environmental air and water analysis. It gives the basic knowledge on this technique, information on analytical equipment and guides the reader to the various applications. This practical handbook is intended as a resource for graduate students, research scientists, and industrial users. (orig.)

  18. Handbook of practical X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Beckhoff, B. [Physikalisch-Technische Bundesanstalt, Berlin (Germany). X-ray Spectrometry; Kanngiesser, B. [Technische Univ. Berlin (Germany). Inst. fuer Atomare Physik und Fachdidaktik; Langhoff, N. [IfG-Institute for Scientific Instruments GmbH, Berlin (Germany); Wedell, R.; Wolff, H. (eds.) [Institut fuer Angewandte Photonik e.V., Berlin (Germany)

    2006-07-01

    X-ray fluorescence analysis (XRF) is a reliable multi-elemental and nondestructive analytical method widely used in research and industrial applications. This practical handbook provides self-contained modules featuring XRF instrumentation, quantification methods, and most of the current applications. The broad spectrum of topics is due to the efforts of a large number of authors from a variety of different types of institutions such as universities, research institutes, and companies. The book gives a survey of the theoretical fundamentals, analytical instrumentation, software for data processing, various excitation regimes including gracing incidents and microfocus measurements, quantitative analysis, applications in routine and micro analysis, mineralogy, biology, medicine, criminal investigations, archeology, metallurgy, abrasion, microelectronics, environmental air and water analysis. It gives the basic knowledge on this technique, information on analytical equipment and guides the reader to the various applications. This practical handbook is intended as a resource for graduate students, research scientists, and industrial users. (orig.)

  19. Determination of heavy metals concentrations in airborne particulates matter (APM) from Manjung district, Perak using energy dispersive X-ray fluorescence (EDXRF) spectrometer

    Science.gov (United States)

    Arshad, Nursyairah; Hamzah, Zaini; Wood, Ab. Khalik; Saat, Ahmad; Alias, Masitah

    2015-04-01

    Airborne particulates trace metals are considered as public health concern as it can enter human lungs through respiratory system. Generally, any substance that has been introduced to the atmosphere that can cause severe effects to living things and the environment is considered air pollution. Manjung, Perak is one of the development districts that is active with industrial activities. There are many industrial activities surrounding Manjung District area such as coal fired power plant, quarries and iron smelting which may contribute to the air pollution into the environment. This study was done to measure the concentrations of Hg, U, Th, K, Cu, Fe, Cr, Zn, As, Se, Pb and Cd in the Airborne Particulate Matter (APM) collected at nine locations in Manjung District area within 15 km radius towards three directions (North, North-East and South-East) in 5 km intervals. The samples were collected using mini volume air sampler with cellulose filter through total suspended particulate (TSP). The sampler was set up for eight hours with the flow rate of 5 L/min. The filter was weighed before and after sample collection using microbalance, to get the amount of APM and kept in desiccator before analyzing. The measurement was done using calibrated Energy Dispersive X-Ray Fluorescence (EDXRF) Spectrometer. The air particulate concentrations were found below the Malaysia Air Quality Guidelines for TSP (260 µg/m3). All of the metals concentrations were also lower than the guidelines set by World Health Organization (WHO), Ontario Ministry of the Environment and Argonne National Laboratory, USA NCRP (1975). From the concentrations, the enrichment factor were calculated.

  20. The determination of copper and nickel in iron- and chromium-bearing materials by a pressed-powder technique and x-ray-fluorescence spectrometry

    International Nuclear Information System (INIS)

    Balaes, A.M.E.; Dixon, K.

    1984-01-01

    A method was developed that is suitable for the determination of copper and nickel in ores such as those from the Merensky and UG-2 Reefs. The sample was ground finely and diluted with river sand so that matrix variations were avoided as much as possible. After the addition of a wax-polystyrene binder, the material was pelletized. The matrix effects of iron and chromium, and the effects of their mutual interferences on the determination of copper and nickel, were then investigated. Equations were derived for the corrected copper and nickel Kα intensities, and were applied to the analyses of head, concentrate, middling, and tailing samples. Comparative values obtained by atomic-absorption spectrophotometry were found to be in reasonable agreement with the X-ray values; the average deviation was +0,3 per cent for copper and -1,6 per cent for nickel relative to the AAS values. The limits of detection of the method for copper and nickel are 31 and 40μg/g respectively; the limit of determination for copper is 92μg/g and for nickel is 119μg/g. The relative standard deviation at 900 and 2400μg of copper and nickel per gram is 0,02

  1. Hyper-filter-fluorescer spectrometer for fusion x-ray diagnostics

    International Nuclear Information System (INIS)

    Wang, C.L.

    1981-01-01

    The filter-fluorescer spectrometer (FFS) is a powerful tool for measuring x-ray spectrum from high fluence x-ray sources. However, this technique is limited to energies less than 120 keV, because there are no practical absorption edges available above this energy. In this paper, we present a new method of utilizing the filter-fluorescer system for x-ray spectral measurement above 120 keV. The new apparatus is called hyper-filter-fluorescer spectrometer

  2. X-ray fluorescence beamline at LNLS: components and some associated techniques

    International Nuclear Information System (INIS)

    Perez, CArlos A.; Radtke, Martin; Perez, Carlos; Tolentino, Helio; Vicentin, Flavio; Sanchez, Hector Jorge; Perez, Roberto D.

    1997-01-01

    Full text. In this work a general description of the Total Reflection X-Ray Fluorescence (TXRF) and the X-Ray Fluorescence Microprobe (XRFM) is presented. Components, equipment and experimental stations for the x-ray fluorescence beamline are described, regarding to the techniques mentioned above. Results from the simulations of a pair bended mirrors in a Kirkpatrick-Baez configuration, are shown. The simulations were performed with Shadow program. (author)

  3. Direct comparison of soft x-ray images of organelles with optical fluorescence images

    International Nuclear Information System (INIS)

    Ishino, Masahiko; Kado, Masataka; Kishimoto, Maki; Nishikino, Masaharu; Ohba, Toshiyuki; Kaihori, Takeshi; Kawachi, Tetsuya; Tamotsu, Satoshi; Yasuda, Keiko; Mikata, Yuji; Shinohara, Kunio

    2011-01-01

    Soft x-ray microscopes operating in the water window region are capable of imaging living hydrated cells. Up to now, we have been able to take some soft x-ray images of living cells by the use of a contact x-ray microscope system with laser produced plasma soft x-ray source. Since the soft x-ray images are different from the optical images obtained with an ordinary microscope, it is very important to identify what is seen in the x-ray images. Hence, we have demonstrated the direct comparison between the images of organelles obtained with a fluorescence microscope and those with a soft x-ray microscope. Comparing the soft x-ray images to the fluorescence images, the fine structures of the organelles could be identified and observed. (author)

  4. Anomalous scattering, transport, and spatial distribution of X-ray fluorescence at the exit of polycapillary structures

    Energy Technology Data Exchange (ETDEWEB)

    Mazuritskiy, M. I., E-mail: mazurmik@gmail.com; Lerer, A. M.; Makhno, P. V. [Southern Federal University (Russian Federation)

    2016-12-15

    The angular distribution of the X-ray intensity at the exit of microchannel plates at grazing incidence of monochromatic radiation on the walls of microcapillaries has been investigated. The angles and energies of the primary radiation quanta at which the synchrotron beam excites X-ray fluorescence propagating inside polycapillary structures have been determined. The angular dependences of the intensity distribution of X-rays transmitted through the microcapillaries have been studied theoretically and experimentally for energies corresponding to the region of anomalous dispersion near the L{sub 2,3} absorption edges of silicon. The propagation of waves in hollow polycapillary waveguides, the excitation of X-ray fluorescence, and the X-ray diffraction at the exit of microchannel plates have been modeled mathematically. The mathematical model takes into account the presence of a transition layer on the microchannel surface.

  5. Analysis of sodium metal by X-ray fluorescence spectrometry (I). Determination of Hf, Mo, Nb, Ta, Ti, V and Zr

    International Nuclear Information System (INIS)

    Diaz-Guerra, J. P.

    1981-01-01

    A method allowing the determination of trace quantities of Hf, Mo, Nb, Ta, Ti, Vi and Zr in sodium metal previous transformation into Na 2 S0 4 is described. The enrichment of the impurities is performed through a coprecipitation technique in sulfuric medium by using Fe 3 + as a collector and cupferron or phenyfluorone as the precipitating reagent. The matrix influence and the best concentration of the collector (10/μ/ml), adequate pH (1,3 or 4, respectively) and optimum filter type (Millipore BSWP02500 or BDWP04700, respectively) have been studied, as well as the precipitation recoveries corresponding to the reagent above. It has been demonstrated the batter efficiency of the cupferron for determining all the Impurities. Detection limits range from 0.01 to 0.2 ppm., depending on the element, for samples 4 g in weight. An automatic spectrometer attached to a 16 K minicomputer and X-ray tube with a gold anode (2250-2700 W) are used. The Interferences between the lines ZrKα (2 n d order) - HfLα and TiKβ - VK α have been studied and the respective correction coefficients have been deduced. (Author) 8 refs

  6. Use of fluorescent-metal intensifying screens with RT-type films for X-ray radiography using pulse devices

    International Nuclear Information System (INIS)

    Morgovskij, L.Ya.; Khakim'yanov, R.R.

    1985-01-01

    A study was made on characteristics of combination of fluorescent-metal Kyokko SMP-308 (Japan) and RCF (Agfa-Gevert) screens with domestic X-ray RT-1, RT-2, RT-5 films. Pulse X-ray MIRA-3D and NORA devices at 200 kV voltage amplitude in X-ray tube were used as radiation source. Testing was conducted for steel samples of 5-40 mm thickness. Comparative exposures for various film combinations with fluorescent-metal screens, fluorescent VP-2 screens and lead foils of 27 μm thickness were determined at that. It is shown that fluorescent-metal screens can be successfully applied with domestic X-ray technical films. They enable to decrease exposure by one order with insignificant deterioration of sensitivity. It is important for testing of pipeline welds

  7. Simultaneous analyses of gaseous and particulate sulphur compounds in the atmosphere by x-ray fluorescence spectrometry, (1)

    International Nuclear Information System (INIS)

    Matsuda, Yatsuka; Mamuro, Tetsuo

    1974-01-01

    An analytical technique for the simultaneous measurements of the atmospheric concentrations of SO 2 gas and sulphur absorbed by aerosol particles has been developed. Aerosol particles are collected on membrane filter and at the same time SO 2 gas is captured on alkali impregnated filter. The sulphur content in each filter is measured by an energy dispersive X-ray fluorescence spectrometer consisting of a Si(Li) semiconductor detector connected to a multichannel pulse hight analyzer and an excitation source of 55 Fe. Two methods are acceptable for the determination of the sulphur content in impregnated filter by X-ray fluorescence analysis. In the first method X-ray fluorescence analysis is made after the collected sulphur has diffused and distributed uniformly enough throughout filter, and in the second method X-ray fluorescence analysis has to be finished before the diffusion of the collected sulphur becomes appreciable. (auth.)

  8. The comparative study of contents of zinc and lead in ore samples of Namtu-Bawdwin Mine by wet analysis, X-ray fluorescence and X-ray diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Kyaw-Soe,

    1990-05-01

    Lead-zinc ores taken from Namtu-Bawdwin area had been analyzed by wet processes in the Department of Chemistry, 1984. These ore samples have been analyzed by energy dispersive X-ray fluorescence method in the Department of Physics and X-ray diffraction method is also used to determine elements of lead and zinc compounds in these ore samples in the University`s Research Centre. In brief, we study comparatively the contents of lead and zinc and their compounds using the methods of wet processes, X-ray fluorescence and X-ray diffraction. (author).

  9. Study of properties of chemically modified samples of halloysite mineral with X-ray fluorescence and X-ray powder diffraction methods

    International Nuclear Information System (INIS)

    Banaś, D.; Kubala-Kukuś, A.; Braziewicz, J.; Majewska, U.; Pajek, M.; Wudarczyk-Moćko, J.; Czech, K.; Garnuszek, M.; Słomkiewicz, P.; Szczepanik, B.

    2013-01-01

    Elemental and chemical composition of raw and activated samples of halloysite mineral using wavelength dispersive X-ray fluorescence (WDXRF), total reflection X-ray fluorescence (TXRF) and X-ray powder diffraction (XRPD) methods were determined. As the result, it has been shown that application of the complementary X-ray spectrometry techniques allows very precise observation of changes in composition of halloysite mineral samples caused by its chemical modifications. Sample preparation procedure and usability of the research methods applied are described in details. Procedure of activation of raw halloysite mineral samples by etching them in sulfuric acid of various concentrations has been described and discussed. The ability of the samples to adsorb lead from intentionally contaminated water was tested and confirmed. - Author-Highlights: • We measured elemental and chemical composition of raw and activated halloysite mineral samples. • We showed that X-ray techniques allow precise study of changes in the sample composition. • We describe procedure of activation of the samples by etching them in sulfuric acid. • We tested ability of halloysite mineral to absorb lead from contaminated water

  10. Structure determination by X-ray crystallography

    CERN Document Server

    Ladd, M F C

    1995-01-01

    X-ray crystallography provides us with the most accurate picture we can get of atomic and molecular structures in crystals. It provides a hard bedrock of structural results in chemistry and in mineralogy. In biology, where the structures are not fully crystalline, it can still provide valuable results and, indeed, the impact here has been revolutionary. It is still an immense field for young workers, and no doubt will provide yet more striking develop­ ments of a major character. It does, however, require a wide range of intellectual application, and a considerable ability in many fields. This book will provide much help. It is a very straightforward and thorough guide to every aspect of the subject. The authors are experienced both as research workers themselves and as teachers of standing, and this is shown in their clarity of exposition. There are plenty of iliustrations and worked examples to aid the student to obtain a real grasp of the subject.

  11. Determination of elemental distribution in green micro-algae using synchrotron radiation nano X-ray fluorescence (SR-nXRF) and electron microscopy techniques--subcellular localization and quantitative imaging of silver and cobalt uptake by Coccomyxa actinabiotis.

    Science.gov (United States)

    Leonardo, T; Farhi, E; Boisson, A-M; Vial, J; Cloetens, P; Bohic, S; Rivasseau, C

    2014-02-01

    The newly discovered unicellular micro-alga Coccomyxa actinabiotis proves to be highly radio-tolerant and strongly concentrates radionuclides, as well as large amounts of toxic metals. This study helps in the understanding of the mechanisms involved in the accumulation and detoxification of silver and cobalt. Elemental distribution inside Coccomyxa actinabiotis cells was determined using synchrotron nano X-ray fluorescence spectroscopy at the ID22 nano fluorescence imaging beamline of the European Synchrotron Radiation Facility. The high resolution and high sensitivity of this technique enabled the assessment of elemental associations and exclusions in subcellular micro-algae compartments. A quantitative treatment of the scans was implemented to yield absolute concentrations of each endogenous and exogenous element with a spatial resolution of 100 nm and compared to the macroscopic content in cobalt and silver determined using inductively coupled plasma-mass spectrometry. The nano X-ray fluorescence imaging was complemented by transmission electron microscopy coupled to X-ray microanalysis (TEM-EDS), yielding differential silver distribution in the cell wall, cytosol, nucleus, chloroplast and mitochondria with unique resolution. The analysis of endogenous elements in control cells revealed that iron had a unique distribution; zinc, potassium, manganese, molybdenum, and phosphate had their maxima co-localized in the same area; and sulfur, copper and chlorine were almost homogeneously distributed among the whole cell. The subcellular distribution and quantification of cobalt and silver in micro-alga, assessed after controlled exposure to various concentrations, revealed that exogenous metals were mainly sequestered inside the cell rather than on mucilage or the cell wall, with preferential compartmentalization. Cobalt was homogeneously distributed outside of the chloroplast. Silver was localized in the cytosol at low concentration and in the whole cell excluding the

  12. Abundance and Charge State of Implanted Solar Wind Transition Metals in Individual Apollo 16 and 17 Lunar Soil Plagioclase Grains Determined In Situ Using Synchrotron X-ray Fluorescence

    International Nuclear Information System (INIS)

    Kitts, K.; Sutton, S.; Newville, M.

    2007-01-01

    We report (1) a new method for determining the relative abundances in situ of Cr, Mn, Fe and Ni in implanted solar wind in individual Apollo 16 and 17 lunar plagioclases via synchrotron X-ray fluorescence and (2) the charge states of these metals. By virture of its mass alone, the Sun provides a representative composition of the solar system and can be used as a background against which to gauge excesses or deficiencies of specific components. One way of sampling the Sun is by measuring solar wind implanted ions in lunar soil grains. Such measurements are valuable because of their long exposure ages which compliment shorter time scale collections, such as those obtained by the Genesis spacecraft. Kitts et al. sought to determine the isotopic composition of solar Cr by analyzing the solar wind implanted into plagioclase grains from Apollo 16 lunar soils. The isotopic composition of the solar wind bearing fraction was anomalous and did not match any other known Cr isotopic signature. This could only be explained by either (1) an enrichment in the solar wind of heavy Cr due to spallation in the solar atmosphere or (2) that the Earth and the various parent bodies of the meteorites are distinct from the Sun and must have formed from slightly different mixes of presolar materials. To help resolve this issue, we have developed a wholly independent method for determining the relative abundances of transition metals in the solar wind implanted in individual lunar soil grains. This method is based on in situ abundance measurements by microbeam x-ray fluorescence in both the implantation zone and bulk grains using the synchrotron x-ray microprobe at the Advanced Photon Source (GSECARS sector 13) at Argonne National Laboratory. Here, we report results for Apollo 16 and 17 plagioclase grains. Additionally, a micro-XANES technique was used to determine charge states of the implanted Cr, Mn, Fe and Ni.

  13. Synthesis, characterization, single crystal X-ray determination, fluorescence and electrochemical studies of new dinuclear nickel(II) and oxovanadium(IV) complexes containing double Schiff base ligands

    Science.gov (United States)

    Shafaatian, Bita; Ozbakzaei, Zahra; Notash, Behrouz; Rezvani, S. Ahmad

    2015-04-01

    A series of new bimetallic complexes of nickel(II) and vanadium(IV) have been synthesized by the reaction of the new double bidentate Schiff base ligands with nickel acetate and vanadyl acetylacetonate in 1:1 M ratio. In nickel and also vanadyl complexes the ligands were coordinated to the metals via the imine N and enolic O atoms. The complexes have been found to possess 1:1 metals to ligands stoichiometry and the molar conductance data revealed that the metal complexes were non-electrolytes. The nickel and vanadyl complexes exhibited distorted square planar and square pyramidal coordination geometries, respectively. The emission spectra of the ligands and their complexes were studied in methanol. Electrochemical properties of the ligands and their metal complexes were also investigated in DMSO solvent at 150 mV s-1 scan rate. The ligands and metal complexes showed both quasi-reversible and irreversible processes at this scan rate. The Schiff bases and their complexes have been characterized by FT-IR, 1H NMR, UV/Vis spectroscopies, elemental analysis and conductometry. The crystal structure of the nickel complex has been determined by single crystal X-ray diffraction.

  14. Development of portable X-ray diffractometer equipped with X-ray fluorescence spectrometer and its application to archaeology

    International Nuclear Information System (INIS)

    Yamashita, Daisuke; Ishizaki, Atsushi; Uda, Masayuki

    2009-01-01

    A portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer was improved so as to obtain a diffraction pattern and a fluorescence spectrum in air from one and the same small area of a specimen. The reason why the portable XRD with an XRF spectrometer was specially designed for archaeology may be understood from the following facts: (1) some objects exhibited in museums are not allowed to be transferred from the open air to a vacuum, even if their volumes are small; (2) some objects are very difficult to move from their original sites; (3) some parts of exhibits are extremely fragile and cannot be examined in a vacuum; and (4) information on the chemical composition and structure from the same area of an object offers a better understanding of the constitutive materials of the object. Some examples of the use of a portable X-ray diffractometer equipped with an X-ray fluorescence spectrometer in the field are also introduced. Experimental results of Sho-kannon, Snew's mask and Tutankhamun's golden mask are shown here. (author)

  15. Application of X-ray fluorescence analytical techniques in phytoremediation and plant biology studies

    International Nuclear Information System (INIS)

    Necemer, Marijan; Kump, Peter; Scancar, Janez; Jacimovic, Radojko; Simcic, Jurij; Pelicon, Primoz; Budnar, Milos; Jeran, Zvonka; Pongrac, Paula; Regvar, Marjana; Vogel-Mikus, Katarina

    2008-01-01

    Phytoremediation is an emerging technology that employs the use of higher plants for the clean-up of contaminated environments. Progress in the field is however handicapped by limited knowledge of the biological processes involved in plant metal uptake, translocation, tolerance and plant-microbe-soil interactions; therefore a better understanding of the basic biological mechanisms involved in plant/microbe/soil/contaminant interactions would allow further optimization of phytoremediation technologies. In view of the needs of global environmental protection, it is important that in phytoremediation and plant biology studies the analytical procedures for elemental determination in plant tissues and soil should be fast and cheap, with simple sample preparation, and of adequate accuracy and reproducibility. The aim of this study was therefore to present the main characteristics, sample preparation protocols and applications of X-ray fluorescence-based analytical techniques (energy dispersive X-ray fluorescence spectrometry-EDXRF, total reflection X-ray fluorescence spectrometry-TXRF and micro-proton induced X-ray emission-micro-PIXE). Element concentrations in plant leaves from metal polluted and non-polluted sites, as well as standard reference materials, were analyzed by the mentioned techniques, and additionally by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). The results were compared and critically evaluated in order to assess the performance and capability of X-ray fluorescence-based techniques in phytoremediation and plant biology studies. It is the EDXRF, which is recommended as suitable to be used in the analyses of a large number of samples, because it is multi-elemental, requires only simple preparation of sample material, and it is analytically comparable to the most frequently used instrumental chemical techniques. The TXRF is compatible to FAAS in sample preparation, but relative to AAS it is fast, sensitive and

  16. Energy-dispersive X-ray fluorescence analysis of cerium in ferrosilicon

    International Nuclear Information System (INIS)

    Marbec, E.R.

    1987-01-01

    The cerium was determined in ferrosilicon samples by energy-dispersive X-ray fluorescence techniques (XRF) techniques, with a secondary target of gadolinium. The methods employed were: comparison and linear regression with reference materials with cerium concentration between 0.4 and 1.0%. The samples were prepared in the form of pellets and the analytical results are reported as an average of five determinations with a confidence limits at 95% probability. (Author) [es

  17. Characteristics of X-ray fluorescence of nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seunghoon; Kwak, Sung-Woo; Shin, Jung-Ki; Park, Uk-Rayng; Jung, Heejun [Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)

    2015-10-15

    LED is a technique of determination of uranium concentration as a continuous X-ray energy beams transmit a uranium liquid sample for safeguards. Compared to K-edge densitometer, due to relatively lower energy (L-edge energy is 17.17 keV) of Uranium L series energy than K-series energy, L-edge densitometer does not require high purity germanium detector with liquid nitride cooling. Therefore, the Ledge densitometer is appropriate for portable equipment for on-site nuclear material inspection and safeguards at facility sites. XRF combined with LED is a technique of finding of nuclear materials from reflected characteristic X-ray photons. In this study, characteristics of XRF of nuclear materials are simulated Monte Carlo method (Geant4) for feasibility of the system for determination of concentration of nuclear species. The analysis method of uranium concentration or minor actinides is applied using combination of linear extrapolation from jump of L-edge of sample and ratio between uranium and minor actinide from XRF measurement. In this study, The XRF ch aracteristics was simulated from Monte Carlo method. The peaks were obtained from nuclear material mixture. The estimated nuclear material concentration is low due to the volume effect of the sample. The correction factor or minimization of the effect is required.

  18. Fast x-ray fluorescence microtomography of hydrated biological samples.

    Directory of Open Access Journals (Sweden)

    Enzo Lombi

    Full Text Available Metals and metalloids play a key role in plant and other biological systems as some of them are essential to living organisms and all can be toxic at high concentrations. It is therefore important to understand how they are accumulated, complexed and transported within plants. In situ imaging of metal distribution at physiological relevant concentrations in highly hydrated biological systems is technically challenging. In the case of roots, this is mainly due to the possibility of artifacts arising during sample preparation such as cross sectioning. Synchrotron x-ray fluorescence microtomography has been used to obtain virtual cross sections of elemental distributions. However, traditionally this technique requires long data acquisition times. This has prohibited its application to highly hydrated biological samples which suffer both radiation damage and dehydration during extended analysis. However, recent advances in fast detectors coupled with powerful data acquisition approaches and suitable sample preparation methods can circumvent this problem. We demonstrate the heightened potential of this technique by imaging the distribution of nickel and zinc in hydrated plant roots. Although 3D tomography was still impeded by radiation damage, we successfully collected 2D tomograms of hydrated plant roots exposed to environmentally relevant metal concentrations for short periods of time. To our knowledge, this is the first published example of the possibilities offered by a new generation of fast fluorescence detectors to investigate metal and metalloid distribution in radiation-sensitive, biological samples.

  19. Layer thickness measurement using the X-ray fluorescence principle

    International Nuclear Information System (INIS)

    Mengelkamp, B.

    1980-01-01

    Curium 244 having a gamma energy of about 15.5 keV is used as excitation emitter for contactless and continuous measuring of the thickness of metallic layers on iron strip. Soft gamma radiation is absorbed in matter according to the photo effect, so that X-ray fluorescence radiation is generated in the matter, which depends on the element and is radiated to all sides. For instance, it amounts for iron 6.4 keV and is measured with a specific ionisation chamber for this energy range. With increasing atomic number of the elements, the energy of fluorescence radiation increases and hence also the emission signal of the detector. The prerequisite for a usable measuring effect is an element distance of at least two and the thickness of the layer to be measured being in an optimum range. A signal dependent on the thickness of the layer is produced either by absorption of iron radiation (absorption method - aluminium and tin) or by build-up radiation of the material of the layer (emission method - zinc and lead). (orig./GSCH) [de

  20. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: a Monte Carlo study.

    Science.gov (United States)

    Manohar, Nivedh; Jones, Bernard L; Cho, Sang Hyun

    2014-10-01

    To develop an accurate and comprehensive Monte Carlo (MC) model of an experimental benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) setup and apply this MC model to optimize incident x-ray spectrum for improving production/detection of x-ray fluorescence photons from gold nanoparticles (GNPs). A detailed MC model, based on an experimental XFCT system, was created using the Monte Carlo N-Particle (MCNP) transport code. The model was validated by comparing MC results including x-ray fluorescence (XRF) and scatter photon spectra with measured data obtained under identical conditions using 105 kVp cone-beam x-rays filtered by either 1 mm of lead (Pb) or 0.9 mm of tin (Sn). After validation, the model was used to investigate the effects of additional filtration of the incident beam with Pb and Sn. Supplementary incident x-ray spectra, representing heavier filtration (Pb: 2 and 3 mm; Sn: 1, 2, and 3 mm) were computationally generated and used with the model to obtain XRF/scatter spectra. Quasimonochromatic incident x-ray spectra (81, 85, 90, 95, and 100 keV with 10 keV full width at half maximum) were also investigated to determine the ideal energy for distinguishing gold XRF signal from the scatter background. Fluorescence signal-to-dose ratio (FSDR) and fluorescence-normalized scan time (FNST) were used as metrics to assess results. Calculated XRF/scatter spectra for 1-mm Pb and 0.9-mm Sn filters matched (r ≥ 0.996) experimental measurements. Calculated spectra representing additional filtration for both filter materials showed that the spectral hardening improved the FSDR at the expense of requiring a much longer FNST. In general, using Sn instead of Pb, at a given filter thickness, allowed an increase of up to 20% in FSDR, more prominent gold XRF peaks, and up to an order of magnitude decrease in FNST. Simulations using quasimonochromatic spectra suggested that increasing source x-ray energy, in the investigated range of 81-100 ke

  1. Characterization of energy response for photon-counting detectors using x-ray fluorescence

    International Nuclear Information System (INIS)

    Ding, Huanjun; Cho, Hyo-Min; Molloi, Sabee; Barber, William C.; Iwanczyk, Jan S.

    2014-01-01

    Purpose: To investigate the feasibility of characterizing a Si strip photon-counting detector using x-ray fluorescence. Methods: X-ray fluorescence was generated by using a pencil beam from a tungsten anode x-ray tube with 2 mm Al filtration. Spectra were acquired at 90° from the primary beam direction with an energy-resolved photon-counting detector based on an edge illuminated Si strip detector. The distances from the source to target and the target to detector were approximately 19 and 11 cm, respectively. Four different materials, containing silver (Ag), iodine (I), barium (Ba), and gadolinium (Gd), were placed in small plastic containers with a diameter of approximately 0.7 cm for x-ray fluorescence measurements. Linear regression analysis was performed to derive the gain and offset values for the correlation between the measured fluorescence peak center and the known fluorescence energies. The energy resolutions and charge-sharing fractions were also obtained from analytical fittings of the recorded fluorescence spectra. An analytical model, which employed four parameters that can be determined from the fluorescence calibration, was used to estimate the detector response function. Results: Strong fluorescence signals of all four target materials were recorded with the investigated geometry for the Si strip detector. The average gain and offset of all pixels for detector energy calibration were determined to be 6.95 mV/keV and −66.33 mV, respectively. The detector’s energy resolution remained at approximately 2.7 keV for low energies, and increased slightly at 45 keV. The average charge-sharing fraction was estimated to be 36% within the investigated energy range of 20–45 keV. The simulated detector output based on the proposed response function agreed well with the experimental measurement. Conclusions: The performance of a spectral imaging system using energy-resolved photon-counting detectors is very dependent on the energy calibration of the

  2. Multi-elemental analysis of marine sediments of Sorsogon Bay using x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gonzales, Ralph Roly A.; Quirit, Leni L.; Rosales, Colleen Marciel F.; Pabroa, Preciosa Corazon B.; Sta Maria, Efren J.

    2011-01-01

    Metal composition and nutrient loadings of our bodies of water, when uncontrolled, may cause harmful bacterial contamination and pose threats in aquatic and human life. Toxic and trace element inputs in Sorsogon Bay sediments were determined using nuclear analytical techniques, more specifically, x-ray fluorescence spectrometry, in this study. Pre-treated marine sediment samples from Sorsogon Bay were homogenized using SPEX # 8000 mixer/mill and agate mortar and pestle, pelletized into 31-mm flat discs using SPEX 3630 X-Press and analyzed using PAN Analytical Epsilon 5 EDX X-ray Fluorescence Spectrometer with the emission and transmission method using silver and germanium secondary targets. Spectrum fitting performed using AXIL (Analysis of X-ray Spectra by Iterative Least-Squares Fitting), a subprogram in Quantitative X-ray Analysis System developed by the International Atomic Energy Agency and Quantitative Analysis of Environmental Samples program, was used for quantification of results. Results indicate generally moderate to high metal enrichment, specifically manganese, lead, cadmium, zinc and copper. Mercury and iron level enrichment are found to be low, marking an improvement from previous studies indicating high enrichment of these metals. (author)

  3. Synchrotron radiation total reflection X-ray fluorescence (SR-TXRF) for evaluation of food contamination

    International Nuclear Information System (INIS)

    Vives, A.E.S.; Brienza, S.M.B.; Moreira, S.; Zucchi, O.L.A.; Nascimento Filho, V.F.

    2006-01-01

    The objective of this study was to use synchrotron radiation total reflection X-ray fluorescence analysis (SR-TXRF) for the determination of metals and other elements in food available to the population in commercial establishments, in order to evaluate the risks of contamination by these products. The analyzed species were vegetables, leafy vegetables, fruits, cereal and grain. The results indicated that some species were contaminated by Cr, Cu, Zn and Pb with concentrations much higher than the reference values. (author)

  4. Radioisotope induced X-ray fluorescence analysis of cereal grains and flour

    International Nuclear Information System (INIS)

    Toeroek, Sz.; Szoekefalvi-Nagy, Z.

    1982-06-01

    Radioisotope-induced X-ray fluorescence analysis is a rather simple and easy method for investigating ashed plant material. In order to reduce matrix effects thin samples of 2 mg/cm 2 are analysed to obtain a reasonable compromise between maximum sensitivity and the lowest possible absorption effects. Concentrations are determined by standard addition method. An accuracy of 6-8% can be achieved. As an application analytical results are given for whole grains of several sorts of wheat. (author)

  5. Ferro-metry and X-ray fluorescence to measure wear

    International Nuclear Information System (INIS)

    Catherin, J.Y.

    1997-01-01

    The determination of wear of metallic structures is carried out by measuring metallic particles in the lubricating oil. This method is routinely used by SNCF, the French railroad company to control the motors of the high speed trains (TGV). Four methods, plasma emission spectrometry, X-ray fluorescence analysis, ferro-metry and magnetometry are used. The field of application and advantage of each method is described. (C.B.)

  6. Application of instrumental neutron activation analysis and X-ray fluorescence analysis in art pieces investigation

    International Nuclear Information System (INIS)

    Panczyk, E.; Kierzek, J.; Walis, L.; Ligeza, M.

    1996-01-01

    The application of instrumental neutron activation analysis have been shown for the trace element identification in dyes of old painting and other art objects. The recognition of their composition is a important measure for attribution. Also the X-ray fluorescence analysis has been frequently used for examination of art objects. The age determination of the old chinese porcelain is a good example described in the paper. 20 refs, 4 figs

  7. Development of suitable plastic standards for X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mans, Christian [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: c.mans@fh-muenster.de; Hanning, Stephanie [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: hanning@fh-muenster.de; Simons, Christoph [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: simons@fh-muenster.de; Wegner, Anne [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: awegner@fh-muenster.de; Janssen, Anton [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: janssena@fh-muenster.de; Kreyenschmidt, Martin [University of Applied Sciences Muenster, Department of Chemical Engineering, Advanced Analytical Chemistry, Stegerwaldstr. 39, 48565 Steinfurt (Germany)], E-mail: martin.kreyenschmidt@fh-muenster.de

    2007-02-15

    For the adoption of the EU directive 'Restriction on use of certain Hazardous Substances' and 'Waste Electrical and Electronic Equipment' using X-ray fluorescence analysis suitable standard materials are required. Plastic standards based on acrylonitrile-butadiene-styrene terpolymer, containing the regulated elements Br, Cd, Cr, Hg and Pb were developed and produced as granulates and solid bodies. The calibration materials were not generated as a dilution from one master batch but rather the element concentrations were distributed over nine independent calibration samples. This was necessary to enable inter-elemental corrections and empirical constant mass absorption coefficients. The produced standard materials are characterized by a homogenous element distribution, which is more than sufficient for X-ray fluorescence analysis. Concentrations for all elements except for Br could be determined by Inductively Coupled Plasma Atomic Emission Spectroscopy after microwave assisted digestion. The concentration of Br was determined by use of Neutron Activation Analysis at Hahn-Meitner-Institute in Berlin, Germany. The correlation of the X-ray fluorescence analysis measurements with the values determined using Inductively Coupled Plasma Atomic Emission Spectroscopy and Neutron Activation Analysis showed a very good linearity.

  8. A set-up of micro-X-ray fluorescence system based on polycapillary X-ray optics and applications for archaeology

    International Nuclear Information System (INIS)

    Cheng Lin; Pan Qiuli; Ding Xunliang; Liu Zhiguo

    2008-01-01

    The paper concerns in the structures, performances and characteristics and applications for archaeology of a new micro-X-ray fluorescence system based on rotating anode X-ray generator and polycapillary X-ray optics. The polycapillary X-ray optics used here can focus the primary X-ray beam down to some tens of micrometers in diameters that allows for non-destructive and local analysis of sub-mm samples with minor/ trace level sensitivity. In order to prove the potentials of this instrument used in archaeology, a piece of Chinese ancient blue and white porcelain produced in Ming Dynasty was analyzed. The results show that intensities of Mn-Kα, Co-Kα are variable in agree with the thick of blue glaze. The correlation analysis indicates the Mn and Co have the best correlations. So, the concentrations or ratios of Mn and Co are crucial to determine the provenance and identify from a fake one of Chinese ancient blue and white porcelain. (authors)

  9. Results of improvement of simultaneous and sequential x-ray fluorescence equipment for quantitative routine analysis

    International Nuclear Information System (INIS)

    Zsamboky, Jozsef

    1985-01-01

    Two main types of x-ray fluorescence analyzers measuring sequentially and simultaneously, respectively, the intensities at given wave lengths are described. The main parts of an up to date x-ray fluorescence analyzer are surveyed in detail. The advantages and disadvantages of both methods are discussed. Some results on calibration and optimization are given. (D.Gy.)

  10. Rapid analysis of molybdenum contents in molybdenum master alloys by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Tongkong, P.

    1985-01-01

    Determination of molybdenum contents in molybdenum master alloy had been performed using energy dispersive x-ray fluorescence (EDX) technique where analysis were made via standard additions and calibration curves. Comparison of EDX technique with other analyzing techniques, i.e., wavelength dispersive x-ray fluorescence, neutron activation analysis and inductive coupled plasma spectrometry, showed consistency in the results. This technique was found to yield reliable results when molybdenum contents in master alloys were in the range of 13 to 50 percent using HPGe detector or proportional counter. When the required error was set at 1%, the minimum analyzing time was found to be 30 and 60 seconds for Fe-Mo master alloys with molybdenum content of 13.54 and 49.09 percent respectively. For Al-Mo master alloys, the minimum times required were 120 and 300 seconds with molybdenum content of 15.22 and 47.26 percent respectively

  11. Single particle transfer for quantitative analysis with total-reflection X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Esaka, Fumitaka; Esaka, Konomi T.; Magara, Masaaki; Sakurai, Satoshi; Usuda, Shigekazu; Watanabe, Kazuo

    2006-01-01

    The technique of single particle transfer was applied to quantitative analysis with total-reflection X-ray fluorescence (TXRF) spectrometry. The technique was evaluated by performing quantitative analysis of individual Cu particles with diameters between 3.9 and 13.2 μm. The direct quantitative analysis of the Cu particle transferred onto a Si carrier gave a discrepancy between measured and calculated Cu amounts due to the absorption effects of incident and fluorescent X-rays within the particle. By the correction for the absorption effects, the Cu amounts in individual particles could be determined with the deviation within 10.5%. When the Cu particles were dissolved with HNO 3 solution prior to the TXRF analysis, the deviation was improved to be within 3.8%. In this case, no correction for the absorption effects was needed for quantification

  12. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    International Nuclear Information System (INIS)

    Moreira, Silvana; Vives, Ana Elisa S. de; Nascimento Filho, Virgilio F.; Zucchi, Orgheda L.D.A.

    2005-01-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 μL of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1μg.L -1 for Mn and Fe to 15μg.L -1 for P. (author)

  13. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  14. Sample analysis using gamma ray induced fluorescent X-ray emission

    Energy Technology Data Exchange (ETDEWEB)

    Sood, B S; Allawadhi, K L; Gandhi, R; Batra, O P; Singh, N [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1983-01-01

    A non-destructive method for the analysis of materials using gamma ray-induced fluorescent x-ray emission has been developed. In this method, special preparation of very thin samples in which the absorption of the incident gamma rays and the emitted fluorescent x-rays is negligible, is not needed, and the absorption correction is determined experimentally. A suitable choice of the incident gamma ray energies is made to minimise enhancement effects through selective photoionization of the elements in the sample. The method is applied to the analysis of a typical sample of the soldering material using 279 keV and 59.5 keV gamma rays from /sup 203/Hg and /sup 241/Am radioactive sources respectively. The results of the analysis are found to agree well with those obtained from the chemical analysis.

  15. Beer analysis by synchrotron radiation total reflection X-ray fluorescence (SR-TXRF)

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Silvana [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo. Dept. de Recursos Hidricos]. E-mail: silvana@fec.unicamp.br; Vives, Ana Elisa S. de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br; Nascimento Filho, Virgilio F. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Lab. de Instrumentacao Nuclear]. E-mail: virgilio@cena.usp.br; Zucchi, Orgheda L.D.A. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Ciencias Farmaceuticas de Ribeirao Preto]. E-mail: olzucchi@fcfrp.usp.br

    2005-07-01

    In this work the concentrations of P, S, Cl, K, Ca, Mn, Fe, Zn and Br in twenty-nine brands of national and international beers were determined by Synchrotron Radiation Total Reflection X-Ray Fluorescence analysis (SR-TXRF). The results were compared with the limits established by the Brazilian Legislation and the nutritive values established by National Agricultural Library (NAL). The measurements were performed at the X-ray Fluorescence Beamline at Synchrotron Light Source Laboratory, in Campinas, Sao Paulo, Brazil, using a polychromatic beam for excitation. A small volume of 5 {mu}L of sample beers containing just an internal standard, used to correct geometry effects, were analyzed without any pre-treatment. The measuring time was 100 s and the detection limits obtained varied from 1{mu}g.L{sup -1} for Mn and Fe to 15{mu}g.L{sup -1} for P. (author)

  16. Determination of rubidium and strontium in geological materials by X-Ray fluorescence spectrometry; Determinacion de rubidio y estroncio en materiales geologicos mediante espectrometria de fluorescencia de rayos X

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M.

    1979-07-01

    In order to determine whole-rock ages by the Rb/Sr procedure, an X-ray fluorescence spectrometry method for the determination of both elements has been developed. The samples are pressed into boric acid backed and ringed pellets with this material as a binding agent. Matrix corrections are made following the determination od the mass absorption coefficients, based on the intensity of the Compton-scattered peak of MoK{alpha}. or MoK{beta}{sub 1}.3. The U. S. Geological Survey granodiorite GSP-1 is used as a reference standard. Spectral-line interferences have been carefully studied and the empirical correction factors determined. A BASIC language program for calculating the Rb and Sr concentrations and the Rb/Sr ratios has been written. (Author) 7 refs.

  17. Fluorescence x-ray analyzer for plating-bath solution

    International Nuclear Information System (INIS)

    Komatsu, Shigemi; Hato, Yoshio; Tono, Miki; Ishijima, Hiroshi

    1984-01-01

    This analyzer was developed for the analysis of plating solution composition and the measurement of plating thickness at the same time in the noble and base metal plating applied to electronic components. The analyzer operates on the principle of fluorescence X-ray measurement which features the capability of high accuracy, non-destructive and multi-element simultaneous analysis. In this paper, the principle of measurement, the configuration of a model SFA 875 analyzer and also the main specifications and measurement examples are described. As the measurement examples, it is described in detail that the model SFA 875 achieved the expansion of the range of application and the improvement of accuracy and the accuracy of simply repeated measurement by combining a digital filter with the linear method of least squares. The digital filter method is that for eliminating noise in data, smoothing spectra and subtracting background. The linear method of least squares is the method for separating the spectra with overlapping peaks into individual peaks. The combination of them allows the analyzer to perform various analyses even by using the spectra obtained with proportional counters. The analysis of the elements whose atomic numbers are close to each other is also possible. The accuracy of measurement of plating thickness is about 0.2 to 2.0 μm, and that of solution composition is about 0.4 to 0.7 g/l. (Wakatsuki, Y.)

  18. Radioisotope sources for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Leonowich, J.; Pandian, S.; Preiss, I.L.

    1977-01-01

    Problems involved in developing radioisotope sources and the characteristics of potentially useful radioisotopes for X-ray fluorescence analysis are presented. These include the following. The isotope must be evaluated for the physical and chemical forms available, purity, half-life, specific activity, toxicity, and cost. The radiation hazards of the source must be considered. The type and amount of radiation output of the source must be evaluated. The source construction must be planned. The source should also present an advance over those currently available in order to justify its development. Some of the isotopes, which are not in use but look very promising, are indicated, and their data are tabulated. A more or less ''perfect'' source within a given range of interest would exhibit the following characteristics. (1) Decay by an isometric transition with little or no internal conversion, (2) Have an intense gamma transition near the absorption edge of the element(s) of interest with no high energy gammas, (3) Have a sufficiently long half-life (in the order of years) for both economic and calibration reasons, (4) Have a sufficiently large cross-section for production in a reasonable amount of time. If there are competing reactions the interfering isotopes should be reasonably short-lived, or if not, be apt to be separated from the isotope chemically with a minimum of difficulty. (T.G.)

  19. Thin film characterization by total reflection x-ray fluorescence

    International Nuclear Information System (INIS)

    Danel, Adrien; Nolot, Emmanuel; Veillerot, Marc; Olivier, Segolene; Decorps, Tifenn; Calvo-Munoz, Maria-Luisa; Hartmann, Jean-Michel; Lhostis, Sandrine; Kohno, Hiroshi; Yamagami, Motoyuki; Geoffroy, Charles

    2008-01-01

    Sensitive and accurate characterization of films thinner than a few nm used in nanoelectronics represents a challenge for many conventional production metrology tools. With capabilities in the 10 10 at/cm 2 , methods usually dedicated to contamination analysis appear promising, especially Total-reflection X-Ray Fluorescence (TXRF). This study shows that under usual configuration for contamination analysis, with incident angle smaller than the critical angle of the substrate, TXRF signal saturation occurs very rapidly for dense films (below 0.5 nm for HfO 2 films on Si wafers using a 9.67 keV excitation at 0.5 deg.). Increasing the incident angle, the range of linear results can be extended, but on the other hand, the TXRF sensitivity is degraded because of a strong increase of the measurement dead time. On HfO 2 films grown on Si wafers, an incident angle of 0.32 deg. corresponding to a dead time of 95% was used to achieve linear analysis up to 2 nm. Composition analysis by TXRF, and especially the detection of minor elements into thin films, requires the use of a specific incident angle to optimize sensitivity. Although quantitative analyses might require specific calibration, this work shows on Co-based films that the ratio between minor elements (W, P, Mo) and Co taking into account their relative sensitivity factors is a good direct reading of the composition

  20. High-throughput screening with micro-x-ray fluorescence

    International Nuclear Information System (INIS)

    Havrilla, George J.; Miller, Thomasin C.

    2005-01-01

    Micro-x-ray fluorescence (MXRF) is a useful characterization tool for high-throughput screening of combinatorial libraries. Due to the increasing threat of use of chemical warfare (CW) agents both in military actions and against civilians by terrorist extremists, there is a strong push to improve existing methods and develop means for the detection of a broad spectrum of CW agents in a minimal amount of time to increase national security. This paper describes a combinatorial high-throughput screening technique for CW receptor discovery to aid in sensor development. MXRF can screen materials for elemental composition at the mesoscale level (tens to hundreds of micrometers). The key aspect of this work is the use of commercial MXRF instrumentation coupled with the inherent heteroatom elements within the target molecules of the combinatorial reaction to provide rapid and specific identification of lead species. The method is demonstrated by screening an 11-mer oligopeptide library for selective binding of the degradation products of the nerve agent VX. The identified oligopeptides can be used as selective molecular receptors for sensor development. The MXRF screening method is nondestructive, requires minimal sample preparation or special tags for analysis, and the screening time depends on the desired sensitivity

  1. Portable x-ray fluorescence spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    This report describes the application of portable X-ray fluorescence (XRF) spectrometry to characterize materials related to deactivation and decommissioning (D and D) of contaminated facilities. Two portable XRF instruments manufactured by TN Spectrace were used in a technology evaluation as part of the Large-Scale Demonstration Project (LSDP) held at the Chicago Pile-5 Research Reactor (CP-5) located at Argonne National Laboratory (ANL). The LSDP is sponsored by the US Department of Energy (DOE), Office of Science and Technology, Deactivation and Decommissioning Focus Are (DDFA). The objective of the LSDP is to demonstrate innovative technologies or technology applications potentially beneficial to the D and D of contaminated facilities. The portable XRF technology offers several potential benefits for rapid characterization of facility components and contaminants, including significant cost reduction, fast turnaround time,a nd virtually no secondary waste. Field work for the demonstration of the portable XRF technology was performed from August 28--September 3, 1996 and October 30--December 13, 1996

  2. Heavy element concentration determination by the x-ray fluorescence analysis using radioisotope {gamma}-ray sources; Dosage d'elements lourds par fluorescence X utilisant des radio-sources de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Enomoto, S [Commissariat a l' Energie Atomique, Dir. des Materiaux et des Combustibles Nucleaires, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    A theoretical and experimental study has been made on the fluorescence analysis of high atomic number element, using {gamma}-ray sources for excitation and characteristic K X-rays for the measurement. The choice of the proper {gamma}-ray energy according to the conditions of the determination is considered. The author has studied the usefulness of using the backscattered {gamma}-rays as a correction mean for matrix and grain-size effects. Sources of {sup 153}Gd, {sup 57}Co, {sup 137}Cs have been used for excitation using collimated geometries. Concentration measurements of tungsten in steel, tungsten and lead in aqueous solution, PbS in SiO{sub 2}-PbS powder mixtures have been done, as well as thickness evaluation of gold layers on copper. A precision of about 0.2 per cent (abs.) is obtained for lead determination in light matrixes. A probe design is proposed for the continuous determination of lead in aqueous solutions. (author) [French] On etudie de maniere theorique et experimentale l'analyse d'elements a nombre atomique eleve par fluorescence en utilisant des sources de rayons {gamma} pour l'excitation, et des rayons-X K caracteristiques pour la mesure. On considere le choix de l'energie appropriee des rayons {gamma} suivant les conditions experimentales. L'utilite d'employer les rayons {gamma} retrodiffuses pour corriger les effets de la matrice et de la dimension des grains est etudiee. Des sources de {sup 153}Gd, de {sup 57}Co et de {sup 137}Cs a geometrie collimatee ont ete utilisees pour l'excitation. Des mesures de la concentration du tungstene dans l'acier, du tungstene et du plomb en solutions aqueuses, et du PbS dans des melanges de poudre SiO{sub 2}-PbS ont ete entreprises ainsi que l'evaluation de l'epaisseur des couches d'or sur le cuivre. On obtient une precision d'environ 0,2 pour cent (en absolu) pour la determination du plomb dans des matrices legeres. On propose un modele de sonde pour la determination en continu du plomb en solution aqueuse

  3. 3D Synchrotron μ-x-ray fluorescence analysis on human bones

    International Nuclear Information System (INIS)

    Zoeger, N.; Wobrauschek, P.; Streli, C.; Chinea-Cano, E.; Wegrzynek, D.; Roschger, P.; Simon, R.; Staub, S.; Falkenberg, G.

    2004-01-01

    A comparison between μ-x-ray fluorescence tomography and confocal μ-x-ray fluorescence analysis (μ-XRF) will be presented. These techniques were used to study the three dimensional (3D) elemental distribution in human bone. Since bone shows very strong inhomogeneities in structure as well as in distribution of the chemical elements, two dimensional (2D) analysis (element mapping) of the samples always led to difficulties in interpreting the results and assigning elemental distributions to microscopic structures. Tomography scans in fluorescence and absorption mode have been carried out simultaneously at the fluo-topo beamline at ANKA, Karlsruhe, to determine the distribution of the elements over the depth of the previously prepared sample from human patella. A monochromatized x-ray beam (17 keV) from a bending magnet station focused by a compound refractive lens to a beamsize of 10 x 5 μm was used to perform the measurements. The transmitted beam signal measured with the SD detector was utilized to apply a simplified absorption correction to XRF tomographic images. Based on the XRF sinograms the elemental distribution within the object cross-section was reconstructed by means of filtered backprojection. The same section of human bone has been analyzed by confocal μ-XRF at HASYLAB, Hamburg, Germany beamline L. With this experiment two polycapillary half lenses were used; one for focusing the previously monochromatized primary x-ray beam onto the sample and the second half lens in front of a Si(Li) detector to get a small inspected area. By overlapping the two foci of the lenses a very well defined volume of investigation could be defined. Scanning the sample up- and downstream it was possible to determine the elemental distribution in depth of the sample. An absorption correction has been applied to get a corrected fluorescence image of the sample. Both methods showed consistent results and allowed a precise localization of the elements of interest. (author)

  4. A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Wu Di; Li Yuhua; Wong, Molly D.; Liu Hong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States)

    2013-05-15

    Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

  5. Application of the X-ray fluorescence analysis and X-ray diffraction in geochemical studies of the Pleistocene tills from Holy Cross Mountains

    International Nuclear Information System (INIS)

    Kubala-Kukuś, A.; Ludwikowska-Kedzia, M.; Banaś, D.; Braziewicz, J.; Majewska, U.; Pajek, M.; Wudarczyk-Moćko, J.

    2013-01-01

    X-ray fluorescence analysis methods (wavelength dispersive X-ray fluorescence analysis (WDXRF) and total reflection X-ray fluorescence (TXRF)) and X-ray powder diffraction (XRPD) have been applied in complementary geochemical studies of the Pleistocene till samples. The XRPD technique gave information about the mineral composition of the analyzed samples while the WDXRF and TXRF studies allowed the fast elemental analysis. The till samples were collected from different regions of Holy Cross Mountains (located in central Poland) which are still not unambiguously described in the context of the geochemical studies of the Quaternary sediments. The analysis was concentrated on the geochemical composition of the till samples both for materials occurring on the surface (characterized by continuous weathering processes) and for samples taken from core borehole. The overriding purpose of these studies is determination of the local lithotype of the tills and its lithologic and petrographic diagnostic properties, including the chemical composition of clay and minerals found in the clay. In the presented work the experimental sets up, sample preparation procedure and measurements programme will be discussed in details. Finally, the elemental and mineral compositions will be presented for studied different groups of the samples. - Highlights: • XRF analysis and X-ray diffraction used in studies of the till samples. • The till samples were collected from different regions of Holy Cross Mountains. • The analysis concentrates both on the samples from surface and from core borehole. • The purpose is determination of the local lithotype of the tills. • The experimental setup, sample preparation, measurements and results are discussed

  6. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  7. Determination of experimental conditions for the analysis of rare-earth elements by X-ray fluorescence spectrometry. Application to oxalates and potassium sulphate matrices

    International Nuclear Information System (INIS)

    Bayon Fuentes, A.; Bermudez Polonio, J.

    1969-01-01

    A previous theoretical and experimental study is carried out in order to analyze the rare earths elements by X-ray florescence spectrometry. All possible spectral interferences are considered. The working conditions for each element were selected, taking into account the peak/background ratio values for the following parameters: tungsten, molybdenum and chromium targets, current and voltage, analyzing crystals, and scintillation and flow proportional counters. Calibration curves were plotted showing the concentration of rare earths elements in oxalates and potassium sulphate matrices, and the theoretical detection limits for each element: are calculated. (Author) 8 refs

  8. Analysis of metals in organic compounds by energy dispersive X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Anjos, Marcelino J.; Lopes, Ricardo T.; Jesus, Edgar F.O. de

    2000-01-01

    Using energy dispersive X-ray fluorescence analysis with an X-ray tube filtered with Ti. It was possible to determine the concentration of the elements at ppm level of several elements: K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn As, Rb, Sr, Y, Zr, and Pb in two types of organic compound enough used in the agriculture: organic compound of urban garbage (Fertilurb) and aviary bed (birds manure). The experimental setup is composed of: x-ray tube (Oxford, 30 kV, 50 μA and W anode), an ORTEC Si-Li detector, with an energy resolution of about 180 eV at 5.9 keV and an ORTEC multichannel-analyser. The X-ray beam is quasi- monochromatic by using Ti filter. The samples were prepared in pellet form with superficial density in the range of 100 mg/cm 2 . The fundamental parameter method was used in order to verify the elemental concentration. The radiation transmission method was going used to the radiation absorption effects correction in the samples. (author)

  9. Quantum electrodynamics of the internal source x-ray holographies: Bremsstrahlung, fluorescence, and multiple-energy x-ray holography

    International Nuclear Information System (INIS)

    Miller, G.A.; Sorensen, L.B.

    1997-01-01

    Quantum electrodynamics (QED) is used to derive the differential cross sections measured in the three new experimental internal source ensemble x-ray holographies: bremsstrahlung (BXH), fluorescence (XFH), and multiple-energy (MEXH) x-ray holography. The polarization dependence of the BXH cross section is also obtained. For BXH, we study analytically and numerically the possible effects of the virtual photons and electrons which enter QED calculations in summing over the intermediate states. For the low photon and electron energies used in the current experiments, we show that the virtual intermediate states produce only very small effects. This is because the uncertainty principle limits the distance that the virtual particles can propagate to be much shorter than the separation between the regions of high electron density in the adjacent atoms. We also find that using the asymptotic form of the scattering wave function causes about a 5 10% error for near forward scattering. copyright 1997 The American Physical Society

  10. Evaluation of methods for mathematical corrections in the determination of niobium and zirconium contents in U-Nb and U-Zr alloys by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Salvador, V.L.R.; Sato, I.M.; Lordello, A.R.

    1985-01-01

    Methods for the determination of niobium and zirconium in U-Nb and U-Zr alloys with the X-ray fluorescence technique are described. The NbK sub(Ab) line, although not under the overlapping effect of the uranium lines as the NbK sub(β) line, although not under the overlapping effect of the uranium lines as the NbK sub(α) is, presents a more intensive absorption effect than this last one; on the other hand the ZrK sub(α) and ZrK sub(β) lines are under the overlapping effect of the uranium spectrum. Such interferences are mathematically corrected by means of relations between the intensities of the lines for the elements and those for the uranium. The technique for the preparation of the samples is the double layer pressed pellet. From the different corrections the best method has showed a precision of 5%. (Author) [pt

  11. Experimental determination of L X-ray fluorescence cross sections for elements with 45 < Z < 50 at 10 keV

    Directory of Open Access Journals (Sweden)

    Edgardo Bonzi

    2014-02-01

    Full Text Available Synchrotron radiation at 10 keV was used to experimentally determine the Ll, L, LI, LII, LI and LII fluorescence cross sections for elements with 45 < Z < 50, as part of an ongoing investigation at low energies. The measured data were compared with calculated values obtained using coefficients from Scofield, Krause and Puri et al. Received: 19 December 2013, Accepted: 20 January 2014; Reviewed by: J. P. Marques, Departamento de Física, Centro de Física Atómica, Fac. de Ciências, Universidade de Lisboa, Portugal.; Edited by: P. Weck; DOI: http://dx.doi.org/10.4279/PIP.060001 Cite as: E V Bonzi, G B Grad, R A Barrea, Papers in Physics 6, 060001 (2014

  12. Numerical simulation study for atomic-resolution x-ray fluorescence holography

    International Nuclear Information System (INIS)

    Xie Honglan; Gao Hongyi; Chen Jianwen; Xiong Shisheng; Xu Zhizhan; Wang Junyue; Zhu Peiping; Xian Dingchang

    2003-01-01

    Based on the principle of x-ray fluorescence holography, an iron single crystal model of a body-centred cubic lattice is numerically simulated. From the fluorescence hologram produced numerically, the Fe atomic images were reconstructed. The atomic images of the (001), (100), (010) crystallographic planes were consistent with the corresponding atomic positions of the model. The result indicates that one can obtain internal structure images of single crystals at atomic-resolution by using x-ray fluorescence holography

  13. X-ray fluorescence in IAEA Member States: Peru[X-ray fluorescence in the IAEA and its Member States

    Energy Technology Data Exchange (ETDEWEB)

    Olivera, P [Instituto Peruano de Energia Nuclear, Lab. de Fluorescencia de Rayos X, Lima (Peru)

    2005-12-15

    The application of the XRF technique performed in our laboratories in the field of archaeology began in 1994. It started with the analysis of different samples, as an incisive tooth, a fragment of occipital, a rib fragment, a segment of dorsal vertebra and small glasses found in the internal surface of a Nazca Culture mummy. In the paleopathological study performed by Dr. Guido Lombardi a {sup 109}Cd excitation source and an X ray spectrometry system were used. The elemental concentrations of Ca, Fe, Zn, and Sr were determined for the paleonutricion studies by using the relationships of Zn/Ca and Sr/Ca. The XRF technique also contributed to the mycobacterium tuberculosis detection in a mummy, supplementing other non destructive tests carried out previously. In recent years, 29 right clavicles belonging to mature individuals were analyzed out of 143 found in the Villa El Salvador area. Sr and Zn concentrations were used to determine the relative proportion of vegetable and animal foods in the population's diet under study. It was concluded that the old residents of this town manifested an omnivorous feeding with carnivorous tendency, due to consumption of products of marine origin. Ceramics have also been analyzed to determine the chemical composition of the paste which was used in the production process. 39 fragments of ceramic from the place called Lomo de Corvina of Villa El Salvador, low valley in Lurin town were analyzed. Thalysis of these samples was focused on quantitative determination of Ti, Fe, Rb, Sr, Y, Zr and Nb, to complement the results obtained by neutron activation analysis. Identification of the pigments used for production of art objects is of great importance for its characterization, authentication and/or restoration. For this reason, we are currently working on identification of pigments used in the decoration of archaeological ceramics. This work started from construction of a portable XRF spectrometer based on a small size, low power X ray

  14. X-ray fluorescence analyzers for investigating postmediaeval pottery from Southern Moravia

    International Nuclear Information System (INIS)

    Trojek, Tomas; Hlozek, Matin; Cechak, Tomas; Musilek, Ladislav

    2010-01-01

    This paper deals with an investigation of ceramic archaeological finds with the use of in-situ X-ray fluorescence analysis. Firstly, three configurations of X-ray fluorescence analyzers constructed and used at the Czech Technical University in Prague are described and compared for use in a non-destructive survey of siliceous materials. Detection limits, depth of analysis, the relation of the analyzed area, the homogeneity of the samples, and variations in the element concentrations are discussed. Secondly, many shards of postmediaeval pottery from Southern Moravia are analyzed with X-ray fluorescence analysis and some of them also with electron microprobe analysis. Selected results are described.

  15. A guide for approval of x-ray fluorescence analysis devices

    International Nuclear Information System (INIS)

    1990-01-01

    This guide has been written to assist manufacturers, distributors and users of x-ray fluorescence analysis devices in the preparation of a submission to the Atomic Energy Control Board (AECB) in support of a request for approval of an x-ray fluorescence analysis device. Prior to the issuance of a Radioisotope licence authorizing the use or possession of an x-ray fluorescence analysis device in Canada, the design and construction of the device must be approved by the AECB. The AECB assessment is limited to the radiation safety aspects of use and packaging for transportation

  16. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  17. Measurement of plutonium in spent nuclear fuel by self-induced x-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Andrew S [Los Alamos National Laboratory; Rudy, Cliff R [Los Alamos National Laboratory; Tobin, Steve J [Los Alamos National Laboratory; Charlton, William S [Los Alamos National Laboratory; Stafford, A [TEXAS A& M; Strohmeyer, D [TEXAS A& M; Saavadra, S [ORNL

    2009-01-01

    Direct measurement of the plutonium content in spent nuclear fuel is a challenging problem in non-destructive assay. The very high gamma-ray flux from fission product isotopes overwhelms the weaker gamma-ray emissions from plutonium and uranium, making passive gamma-ray measurements impossible. However, the intense fission product radiation is effective at exciting plutonium and uranium atoms, resulting in subsequent fluorescence X-ray emission. K-shell X-rays in the 100 keV energy range can escape the fuel and cladding, providing a direct signal from uranium and plutonium that can be measured with a standard germanium detector. The measured plutonium to uranium elemental ratio can be used to compute the plutonium content of the fuel. The technique can potentially provide a passive, non-destructive assay tool for determining plutonium content in spent fuel. In this paper, we discuss recent non-destructive measurements of plutonium X-ray fluorescence (XRF) signatures from pressurized water reactor spent fuel rods. We also discuss how emerging new technologies, like very high energy resolution microcalorimeter detectors, might be applied to XRF measurements.

  18. Microprocessor-based system for automatic X-ray diffraction and fluorescence

    International Nuclear Information System (INIS)

    Souza, A.M. de; Carmo, L.C.S. do; Pereira, V.J.E.; Soares, E.A.

    1984-01-01

    A data acquisition and processing device appropriate for X-ray analysis and goniometer control was built. The Z-80 based system as well as the whole architeture is described. The advantages and new possibilities of the automated instrument as compared to the traditional ones are listed. The X-ray diffraction and fluorescence techniques can take advantage of the automation. (Author) [pt

  19. Use of a 55Fe radioisotope for the determination of titanium in laterite samples via energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    La Brecque, J.J.

    1978-01-01

    A rapid method for the determination of titanium in geochemical samples using a 55 Fe radioisotope at the extraction source coupled to a Si(Li) detector and a PDP-11/05 computer is described. A representative sample of about 200 g is ground in a large mortar and pestle before it is passed through a 20 mesh sieve. The 20 mesh sample is mixed thoroughly and quartered, then a 5 g subsample is passed completely through a 150 mesh sieve. Both the sample and internal standard K 2 Cr 2 O 7 are dried at 105 deg C before a 250 mg portion of each is weighed and thoroughly mixed. Three 50-100 mg portions are placed in separate sample holders. The sample holder is a simple card with a 1.5 cm diameter opening in which the sample is inserted between two layers of Magic Scotch tape. The relative standard deviation for a thin sample about 100 mg in weight is less than 4% and it is achieved in a fluorescent time of 100 sec. Data are given for the use of two different internal standards, KBrO 2 and K 2 Cr 2 O 7 , the latter being more precise. The values for five international reference standards determined by this method are in agreement with the reported values. (T.G.)

  20. X-Ray Fluorescence Spectroscopy for Analysis of Explosive-Related Materials and Unknowns

    Science.gov (United States)

    2017-08-01

    instrument uses a 50 W X-ray tube with a Pd target and has a sample chamber with a six- sample turret. The maximum sample size is 44 mm in diameter by...absorbance of X-rays by the elements present, and the X-ray fluorescence following excitation from other X-rays produced by the sample . Qualitative data...CAN2 Big Approximately 7.6 g of weathered CAN, enough to fill a sample cup To investigate possible errors associated with small sample size

  1. X-ray fluorescence in IAEA Member States: Greece

    International Nuclear Information System (INIS)

    Karydas, A.

    2004-01-01

    The Laboratory of Material Analysis (LMA) of the Institute of Nuclear Physics (INP) at the National Center for Scientific Research (NCSR) 'Demokritos', has been involved very actively during the past few years in the development, evaluation and analytical application of portable X-Ray Fluorescence (XRF) instruments, applied in particular for the non-destructive analysis of cultural materials. The study, conservation and preservation of cultural materials are considered nowadays issues of main concern for countries and international cultural organizations. Due to the strong interest and motivation from archaeologists, conservators and archaeometrical scientists in Greece and elsewhere, a large network has been developed involving the LMA and archaeologists/conservator scientists from Museums (Benaki Museum in Athens), Cultural Foundations (Thera Foundation P. Nomikos), the Greek Ministry of Culture-Conservation Department, Foreign Schools in Greece (American School of Classical Studies, French School of Athens), Universities (Department of Conservation of Antiquities and Works of Art in the Technological Educational Institution of Athens, University of Cincinnatti, Universite de Paris I, Pantheon Sorbonne), private sectors (THETIS, Thetis Authentics - Science and Techniques for Art History Conservation Ltd) and Institutions (Centre de Recherche et de Rastauration des Musees de France, LNS-INFN, LANDIS group). A variety of cultural materials/artifacts have been examined so far, including ceramic vases with colored decoration, bronze artifacts, wall-painting pigments, traces of polychromy on marble sculptures, Gold and Silver ancient jewelry, Gemstones, Roman Coins. Our research and analytical applications of the in-situ XRF analysis have been focused so far on the following: 1) optimum selection and integration of portable XRF instrumentation for improving analytical and sensitivity range; 2) evaluation of the potential of in-situ XRF analysis to provide specific

  2. Elimination of matrix effect in quantitative analysis of elements using x-ray fluorescence

    International Nuclear Information System (INIS)

    Sampaio, R.V.

    1973-07-01

    The emission-transmission method of Leroux and Mahmud, an experimental technique for compensating matrix effects in photon excited X-ray fluorescence analysis, was used to determine the concentration of lead and antimony in pellets of galalith. The effect of interfering elements was studied by adding various concentrations of mercury and tin to the respective pellets. To illustrate possible environmental applications, a number of pellets was prepared from leaves of almond trees located in different regions of Rio de Janeiro. Lead concentrations were determined for the dried leaf material and showed values ranging from 50 to 145 parts per million [pt

  3. Quantitative determination of phases by X-ray diffraction

    International Nuclear Information System (INIS)

    Azevedo, A.L.T.

    1979-01-01

    The internal standard method for the quantitative determination of phases by X-ray diffraction is presented. The method is applicable to multi-phase materials which may be treated as powder. A discussion on sample preparation and some examples follow. (Author) [pt

  4. Residual cold-work determination by X-ray diffraction

    International Nuclear Information System (INIS)

    Pireau, A.; Vanderborck, Y.

    1990-01-01

    The determination of the cold-work level of materials for fast breeder reactors can be made by different techniques. The report compares different methods for an application on austenitic stainless steels and demonstrates that the X-ray diffraction procedure is a reliable technique. A round robin test has been performed between three laboratories; the results are presented and discussed

  5. Application of total reflection X-ray fluorescence spectrometry for ...

    Indian Academy of Sciences (India)

    Applicability of total reflection X-ray fluorescence (TXRF) spectrometry for trace elemental analysis of rainwater samples was studied. The study was used to develop these samples as rainwater standards by the National University of Singapore (NUS). Our laboratory was one of the participants to use TXRF for this study.

  6. Standard test methods for chemical analysis of ceramic whiteware materials using wavelength dispersive X-Ray fluorescence spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover the determination of ten major elements (SiO2, Al2O3, Fe2O3, MgO, CaO, Na2O, K2O, TiO2, P2O5, MnO, and LOI in ceramic whitewares clays and minerals using wavelength dispersive X-ray fluorescence spectrometry (WDXRF). The sample is first ignited, then fused with lithium tetraborate and the resultant glass disc is introduced into a wavelength dispersive X-ray spectrometer. The disc is irradiated with X-rays from an X-ray tube. X-ray photons emitted by the elements in the samples are counted and concentrations determined using previously prepared calibration standards. (1) In addition to 10 major elements, the method provides a gravimetric loss-on-ignition. Note 1—Much of the text of this test method is derived directly from Major element analysis by wavelength dispersive X-ray fluorescence spectrometry, included in Ref (1). 1.2 Interferences, with analysis by WDXRF, may result from mineralogical or other structural effects, line overlaps, and matrix effects. The structure of the...

  7. Fluorescent x-ray computed tomography to visualize specific material distribution

    Science.gov (United States)

    Takeda, Tohoru; Yuasa, Tetsuya; Hoshino, Atsunori; Akiba, Masahiro; Uchida, Akira; Kazama, Masahiro; Hyodo, Kazuyuki; Dilmanian, F. Avraham; Akatsuka, Takao; Itai, Yuji

    1997-10-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT systems consists of a silicon channel cut monochromator, an x-ray slit and a collimator for detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the K(alpha) line, incident monochromatic x-ray was set at 37 keV. At 37 keV Monte Carlo simulation showed almost complete separation between Compton scattering and the K(alpha) line. Actual experiments revealed small contamination of Compton scattering on the K(alpha) line. A clear FXCT image of a phantom was obtained. Using this system the minimal detectable dose of iodine was 30 ng in a volume of 1 mm3, and a linear relationship was demonstrated between photon counts of fluorescent x-rays and the concentration of iodine contrast material. The use of high incident x-ray energy allows an increase in the signal to noise ratio by reducing the Compton scattering on the K(alpha) line.

  8. A strategy for vitrification product assurance and control with X-ray fluorescence spectrometry (PACX)

    International Nuclear Information System (INIS)

    Resce, J.L.

    1995-01-01

    A product control strategy is proposed for the vitrification of low-level and/or mixed waste. This strategy is called Product Assurance and Control with X-ray fluorescence spectrometry (PACX). The strategy utilizes sequential wavelength dispersive x-ray fluorescence spectrometry and standardless fundamental parameters calculations to analyze both the melter feed and the glassy products. The melter feed is sampled prior to addition to the melt tank and then melted and cast into samples which should closely resemble the product from the vitrification process itself. The resulting sample disks are then analyzed by x-ray fluorescence spectrometry. All elements with atomic numbers down to sodium can be determined directly and then either boron or lithium can be determined by difference from the mass balance. The XRF intensities are converted into oxide compositions with the use of a novel standardless fundamental parameters program. Previous work has shown that there is an excellent correlation between the XRF results and the results from conventional wet chemical analyses, but the XRF results can be obtained within two to three hours of sampling. If compositional control limits for durability are available, the product acceptability can be determined prior to the batch being introduced into the melter. The durability could also be estimated from a model, if available, which predicts product durability from composition. If the predicted durability is estimated to be too low, the model can then be used to determine additives which will raise the durability of the final product to within acceptable limits. The additives can then be incorporated into the batch prior to addition into the melter. A similar XRF analysis can be carried out on the glass product from the melter which can then be used to predict and thus assure product acceptance

  9. Micro-beam X-ray fluorescence and absorption imaging techniques at the IAEA Laboratories

    International Nuclear Information System (INIS)

    Wegrzynek, Dariusz; Markowicz, A.; Bamford, S.; Chinea-Cano, E.; Bogovac, M.

    2005-01-01

    X-ray tube based, micro-beam X-ray fluorescence scanning spectrometer has been equipped with two energy dispersive X-ray detectors. The two-detector configuration allows for simultaneous collection of X-ray fluorescence (XRF) and transmitted X-ray beam signals with a spatial resolution in the range of 10-50 μm, depending on the X-ray focussing element in use. The XRF signal is collected with a standard, liquid nitrogen cooled Si(Li) detector. The X-ray beam transmitted through the sample is acquired with a thermoelectrically cooled, silicon drift (SD) detector. The data acquisition is carried out in a fully automatic way under control of the SPECTOR-LOCATOR software. The software controls the scanning procedure and X-ray spectra acquisition during the scan. The energy dispersive X-ray spectra collected at every 'pixel' are stored for off-line processing. For selected regions of interest (ROI's), the element maps are constructed and displayed on-line. The spectrometer has been used for mapping elemental distributions and for performing 2D- and 3D-tomograpic imaging of minute objects in X-ray absorption and in X-ray fluorescence mode. A unique feature of the described system is simultaneous utilization of the two detectors, Si(Li) and SD, which adds new options for quantitative analysis and data interpretation. Examples of elemental mapping and 3D tomographic imaging as well as the advanced features of the SPECTOR-LOCATOR measurement control and data acquisition software are presented in this work

  10. Sweeping total reflection X-ray fluorescence optimisation to monitor the metallic contamination into IC manufacturing

    International Nuclear Information System (INIS)

    Borde, Yannick; Danel, Adrien; Roche, Agnes; Veillerot, Marc

    2008-01-01

    Among the methods available on the market today to control as metallic contamination in integrated circuit manufacturing, Sweeping Total reflection X-ray Fluorescence mode appears a very good method, providing fast and entire wafer mapping. With the goal of a pertinent use of Sweeping Total reflection X-ray Fluorescence in advanced Integrated Circuit manufacturing this work discusses how acceptable levels of contamination specified by the production (low levels to be detected) can be taken into account. The relation between measurement results (surface coverage, throughput, low limit of detection, limit of quantification, quantification of localized contamination) and Sweeping Total reflection X-ray Fluorescence parameters (number of measurement points and integration time per point) is presented in details. In particular, a model is proposed to explain the mismatch between actual surface contamination in a localized spot on wafer and Total reflection X-ray Fluorescence reading. Both calibration and geometric issues have been taken into account

  11. Qualitative and quantitative determination of sediments phases in Chillon River by x-ray diffraction

    International Nuclear Information System (INIS)

    Miramira Tipula, Biviano; Zeballos Velasquez, Elvira; Chui Betancur, Heber; Valencia Salazar, Edilberto; Huaypar Vasquez, Yesena; Olivera de Lescano, Paula

    2008-01-01

    With this paper, we pretend to contribute with the recovery of Chillon River from a characterization of sediments. The objectives are the identification of pollution places along the bed of the Chillon River, from the Canta Province to Lima Province (Comas) and the determination of the preponderant factors of pollution. The qualitative and semi-quantitative determination of the sediments components have been carried out using the x-ray diffraction and x-ray fluorescence techniques, both of them will allow us to identify the pollute elements, for example the lead level in the Chillon River. (author)

  12. X-ray spectral determination by detection of radiation scattered at different angles

    International Nuclear Information System (INIS)

    Barrea, Raul; Mainardi, R.T.

    1987-01-01

    A precise knowledge of the spectral content of an X-ray beam is of fundamental importance in areas such as X-ray fluorescence analysis by absolute methods, radiodiagnosis, radiotherapy, computed tomography, etc. A simple practical method was developed to determine X-ray spectra emitted by X-ray tubes. It is based on the scattering of the beam on a solid target and detection of this radiation at different angles. This methodology can easily be adapted to the successive attenuation of the beam procedure. Numerical parameter values of a proposed analytical function for the energy spectrum are found measuring the radiation intensity with a suitable detector (ionization chamber or plastic scintillation detector) and equating it with the convolution integral of the proposed spectrum with the incoherent scattering function. This procedure of spectra determination is enclosed in the same group of those generically referred as successive modifications of the irradiation set up used in absolute methods of X-ray fluorescence analysis. (Author) [es

  13. Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera

    Energy Technology Data Exchange (ETDEWEB)

    Fittschen, Ursula Elisabeth Adriane, E-mail: ursula.fittschen@chemie.uni-hamburg.de [Institut für Anorganische und Angewandte Chemie, Universität Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Menzel, Magnus [Institut für Anorganische und Angewandte Chemie, Universität Hamburg, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Scharf, Oliver [IfG Institute for Scientific Instruments GmbH, Berlin (Germany); Radtke, Martin; Reinholz, Uwe; Buzanich, Günther [BAM Federal Institute of Materials Research and Testing, Berlin (Germany); Lopez, Velma M.; McIntosh, Kathryn [Los Alamos National Laboratory, Los Alamos, NM (United States); Streli, Christina [Atominstitut, TU Wien, Vienna (Austria); Havrilla, George Joseph [Los Alamos National Laboratory, Los Alamos, NM (United States)

    2014-09-01

    Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by “drop on demand” technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. - Highlights: • Use of a color X-ray camera and drop on demand printing to diagnose X-ray shading • Specimens were obtained uniform and well-defined in shape and concentration by printing. • Direct visualization and determination of shading in such specimens using the camera.

  14. Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera

    International Nuclear Information System (INIS)

    Fittschen, Ursula Elisabeth Adriane; Menzel, Magnus; Scharf, Oliver; Radtke, Martin; Reinholz, Uwe; Buzanich, Günther; Lopez, Velma M.; McIntosh, Kathryn; Streli, Christina; Havrilla, George Joseph

    2014-01-01

    Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by “drop on demand” technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. - Highlights: • Use of a color X-ray camera and drop on demand printing to diagnose X-ray shading • Specimens were obtained uniform and well-defined in shape and concentration by printing. • Direct visualization and determination of shading in such specimens using the camera

  15. Precision and accuracy of multi-element analysis of aerosols using energy-dispersive x-ray fluorescence

    International Nuclear Information System (INIS)

    Adams, F.; Van Espen, P.

    1976-01-01

    Measurements have been carried out for the determination of the inherent errors of energy-dispersive X-ray fluorescence and for the evaluation of its precision and accuracy. The accuracy of the method is confirmed by independent determinations on the same samples using other analytical methods

  16. Application of radionuclide sources for excitation in energy-dispersive X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Hoffmann, P.

    1986-01-01

    X-ray fluorescence (XRF) analysis is in broad application in many fields of science where elemental determinations are necessary. Solid and liquid samples are analyzed by this method. Solids are introduced in thin or thick samples as melted glass, pellets, powders or as original specimen. The excitation of X-ray spectra can be performed by specific and polychromic radiation of X-ray tubes, by protons, deuterons, α-particles, heavy ions and synchrotron radiation from accelerators and by α-particles, X- and γ-rays and by bremsstrahlung generated by β - -particles from radionuclide sources. The radionuclides are devided into groups with respect to their decay mode and the energy of the emitted radiation. The broad application of radionuclides in XRF excitation is shown in examples as semi-quantitative analysis of glasses, as quantitative analysis of coarse ceramics and as quantitative determination of heavy elements (mainly actinides) in solutions. The advantages and disadvantages of radionuclide excitation in XRF analysis are discussed. (orig.) [de

  17. Radionuclide X-ray fluorescence analysis of components of the environment

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Havranek, E.; Dejmkova, E.

    1983-12-01

    The physical foundations and methodology are described of radionuclide X-ray fluorescence analysis. The sources are listed of air, water and soil pollution, and the transfer of impurities into biological materials is described. A detailed description is presented of the sampling of air, soil and biological materials and their preparation for analysis. Greatest attention is devoted to radionuclide X-ray fluorescence analysis of the components of the environment. (ES)

  18. Uncertainty calculations for the measurement of in vivo bone lead by x-ray fluorescence

    International Nuclear Information System (INIS)

    O'Meara, J M; Fleming, D E B

    2009-01-01

    In order to quantify the bone lead concentration from an in vivo x-ray fluorescence measurement, typically two estimates of the lead concentration are determined by comparing the normalized x-ray peak amplitudes from the Kα 1 and Kβ 1 features to those of the calibration phantoms. In each case, the normalization consists of taking the ratio of the x-ray peak amplitude to the amplitude of the coherently scattered photon peak in the spectrum. These two Pb concentration estimates are then used to determine the weighted mean lead concentration of that sample. In calculating the uncertainties of these measurements, it is important to include any covariance terms where appropriate. When determining the uncertainty of the lead concentrations from each x-ray peak, the standard approach does not include covariance between the x-ray peaks and the coherently scattered feature. These spectral features originate from two distinct physical processes, and therefore no covariance between these features can exist. Through experimental and simulated data, we confirm that there is no observed covariance between the detected Pb x-ray peaks and the coherently scattered photon signal, as expected. This is in direct contrast to recent work published by Brito (2006 Phys. Med. Biol. 51 6125-39). There is, however, covariance introduced in the calculation of the weighted mean lead concentration due to the common coherent normalization. This must be accounted for in calculating the uncertainty of the weighted mean lead concentration, as is currently the case. We propose here an alternative approach to calculating the weighted mean lead concentration in such a way as to eliminate the covariance introduced by the common coherent normalization. It should be emphasized that this alternative approach will only apply in situations in which the calibration line intercept is not included in the calculation of the Pb concentration from the spectral data: when the source of the intercept is well

  19. LCLS in—photon out: fluorescence measurement of neon using soft x-rays

    Science.gov (United States)

    Obaid, Razib; Buth, Christian; Dakovski, Georgi L.; Beerwerth, Randolf; Holmes, Michael; Aldrich, Jeff; Lin, Ming-Fu; Minitti, Michael; Osipov, Timur; Schlotter, William; Cederbaum, Lorenz S.; Fritzsche, Stephan; Berrah, Nora

    2018-02-01

    We measured the fluorescence photon yield of neon upon soft x-ray ionization (∼1200 eV) from the x-ray free-electron laser at Linac Coherent Light Source, and demonstrated the usage of a grazing incidence spectrometer with a variable line spacing grating to perform x-ray fluorescence spectroscopy on a gas phase system. Our measurements also allowed us to estimate the focal size of the beam from the theoretical description developed, in terms of the rate equation approximation accounting for photoionization shake off of neutral neon and double auger decay of single core holes.

  20. The application of X-ray fluorescence spectrometry to prospecting potential gold deposits

    International Nuclear Information System (INIS)

    Shang Fengjun; Wang Haixia; Zhou Rongsheng

    2001-01-01

    The fieldwork high-sensitivity X-ray fluorescence analysis (FXFA) adopting miniaturized X-ray tube, Si-PIN detector with peltier cooler and notebook PC spectrometry is presented. Using this system, the authors carried out a preliminary research of its application to some gold mine in Sichuan. According to the close relationship between the high-grade element arsenic and gold in ore-forming components, X-ray fluorescence spectrometry can be used to reveal the existence of potential gold mineralization in fields rapidly. This is of great significance in guiding the field geological collection