International Nuclear Information System (INIS)
Groeneveld, D.C.; Vasic, A.Z.; Leung, L.K.H.; Durmayaz, A.; Shan, J.Q.; Yang, J.; Cheng, S.C.
2005-01-01
Full text of publication follows: CHF Look-up tables have been used widely for the prediction of the Critical Heat Flux (CHF) The CHF look-up table is basically a normalized data bank. The first CHF look-up table was constructed by Doroshchuk et al. (1975), using a limited database of 5 000 data points. This table, and all subsequent tables, contain normalized CHF values for a vertical 8 mm water-cooled tube for various pressures, mass fluxes and qualities. The CHF table development work has since been in progress at various institutions (e.g. CENG-Grenoble, University of Ottawa (UO), Ottawa, IPPE, Obninsk, and AECL, Chalk River) using an ever increasing data base. The 1995 CHF look-up table employs a data base containing about 30 000 CHF points and provides CHF values for an 8 mm ID, water-cooled tube, for 19 pressures, 20 mass fluxes, and 23 qualities. covering the full range of conditions of practical interest. The 2005 CHF LUT is an update to the 1995 LUT and addresses several concerns raised in the literature. The major improvements made are: - enhancement of the quality of the data base of the CHF look-up table (identify outliers, improve screening procedures); - increase in the data base by adding recently obtained data; - employment of greater subdivision of the look-up table by using smaller intervals in the independent parameters (pressure, mass flux and quality) at conditions where the variation in CHF is significant; - improvement of the smoothness of the CHF look-up table. This was done by the use of logarithmic functions for CHF, using optimum Spline functions etc. A discussion of the impact of these changes on the prediction accuracy and table smoothness is presented. It will be shown that the 2005 CHF look-up table is characterized by a significant improvement in accuracy and smoothness. [1] D. Groeneveld is the corresponding author. He is an Adjunct Professor at the University of Ottawa. (authors)
Finite perturbation studies of magnetic susceptibility and shielding with GIAO
International Nuclear Information System (INIS)
Zaucer, M.; Pumpernik, D.; Hladnik, M.; Azman, A.
1977-01-01
The magnetic susceptibility tensor and proton and fluorine magnetic shielding tensors are calculated for F 2 and (FHF) - using an ab initio finite perturbation method with gauge-invariant atomic orbitals (GIAO). The discussion of the basis set deficiency shows that the calculated values for the susceptibilities are reliable. Simple additivity (Pascal rule) for the susceptibility is confirmed. (orig.) [de
International Nuclear Information System (INIS)
Iguchi, Tadashi; Anoda, Yoshinari
2002-02-01
Authors performed post-CHF experiments under wider pressure ranges of 2 MPa - 18 MPa, wider mass flux ranges of 33 kg/m 2 s - 1651 kg/m 2 s and wider superheat of heaters up to 500 K in comparison to experimental ranges at previous post-CHF experiments. Data on boiling transition, critical heat flux and post-CHF heat transfer coefficient were obtained. Used test section was 4x4-rod bundle with heaters, which diameter and length were the same as those of BWR nuclear fuels. As the result of the experiments, it was found that the boiling transition occurred just below several grid spacers, and that the fronts of the boiling transition region proceeded lower with increase of heated power. Heat transfer was due to nucleate boiling above grid spacers, while it was due to film boiling below grid spacers. Consequently, critical heat flux is affected on the distance from the grid spacers. Critical heat flux above the grid spacers was about 15% higher than that below the grid spacers, by comparing them under the same local condition. Heat transfer by steam turbulent flow was dominant to post-CHF heat transfer, when superheat of heaters was sufficiently high. Then, post-CHF heat transfer coefficient was predicted with heat transfer correlations for single-phase flow. On the other hand, when superhead of heaters was not sufficiently high, post-CHF heat transfer coefficient was higher than the prediction with heat transfer correlations for single-phase flow. Mass flux effect on post-CHF heat transfer coefficient was described by standardization of post-CHF heat transfer coefficient with the prediction for single-phase flow. However, pressure effect, superheat effect and effect of position were not described. Authors clarified that those effects could be described with functions of heater temperature and position. Post-CHF heat transfer coefficient was lowest just blow the grid spacers, and it increased with the lower positions. It increased by about 30% in one span of the grid
Energy Technology Data Exchange (ETDEWEB)
Iguchi, Tadashi; Anoda, Yoshinari [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Iwaki, Chikako [Toshiba Corp., Tokyo (Japan)
2002-02-01
Authors performed post-CHF experiments under wider pressure ranges of 2 MPa - 18 MPa, wider mass flux ranges of 33 kg/m{sup 2}s - 1651 kg/m{sup 2}s and wider superheat of heaters up to 500 K in comparison to experimental ranges at previous post-CHF experiments. Data on boiling transition, critical heat flux and post-CHF heat transfer coefficient were obtained. Used test section was 4x4-rod bundle with heaters, which diameter and length were the same as those of BWR nuclear fuels. As the result of the experiments, it was found that the boiling transition occurred just below several grid spacers, and that the fronts of the boiling transition region proceeded lower with increase of heated power. Heat transfer was due to nucleate boiling above grid spacers, while it was due to film boiling below grid spacers. Consequently, critical heat flux is affected on the distance from the grid spacers. Critical heat flux above the grid spacers was about 15% higher than that below the grid spacers, by comparing them under the same local condition. Heat transfer by steam turbulent flow was dominant to post-CHF heat transfer, when superheat of heaters was sufficiently high. Then, post-CHF heat transfer coefficient was predicted with heat transfer correlations for single-phase flow. On the other hand, when superhead of heaters was not sufficiently high, post-CHF heat transfer coefficient was higher than the prediction with heat transfer correlations for single-phase flow. Mass flux effect on post-CHF heat transfer coefficient was described by standardization of post-CHF heat transfer coefficient with the prediction for single-phase flow. However, pressure effect, superheat effect and effect of position were not described. Authors clarified that those effects could be described with functions of heater temperature and position. Post-CHF heat transfer coefficient was lowest just blow the grid spacers, and it increased with the lower positions. It increased by about 30% in one span of
Lifescience Database Archive (English)
Full Text Available CH (Link to library) CHF177 (Link to dictyBase) - - - Contig-U11892-1 - (Link to Or...iginal site) - - CHF177Z 395 - - - - Show CHF177 Library CH (Link to library) Clone ID CHF177 (Link to dicty...Base) Atlas ID - NBRP ID - dictyBase ID - Link to Contig Contig-U11892-1 Original site URL http://dictycdb.b...LLLWDVQGFPCXFAVEG GQCIDPSSLKVGGKYSFIAFSTCRXKFDNQKIHDCDWIIQGPTTPSXCANCGKICTSKCT TNYCDRDXQT Translated Amino A...XKFDNQKIHDCDWIIQGPTTPSXCANCGKICTSKCT TNYCDRDXQT Homology vs CSM-cDNA Score E Sequences producing significant
Counter-current flow limited CHF in thin rectangular channels
International Nuclear Information System (INIS)
Cheng, L.Y.
1990-01-01
An analytical expression for counter-current-flow-limitation (CCFL) was used to predict critical heat flux (CHF) for downward flow in thin vertical rectangular channels which are prototypes of coolant channels in test and research nuclear reactors. Top flooding is the mechanism for counter-current flow limited CHF. The CCFL correlation also was used to determine the circulation and flooding-limited CHF. Good agreements were observed between the period the model predictions and data on the CHF for downflow. The minimum CHF for downflow is lower than the flooding-limited CHF and it is predicted to occur at a liquid flow rate higher than that at the flooding limit. 17 refs., 7 figs
Effect of axial heat flux distribution on CHF
Energy Technology Data Exchange (ETDEWEB)
Park, Cheol
2000-10-01
Previous investigations for the effect of axial heat flux distributions on CHF and the prediction methods are reviewed and summarized. A total of 856 CHF data in a tube with a non-uniform axial heat flux distribution has been compiled from the articles and analyzed using the 1995 Groeneveld look-up table. The results showed that two representative correction factors, K5 of the look-up table and Tongs F factor, can be applied to describe the axial heat flux distribution effect on CHF. However, they overpredict slightly the measured CHF, depending on the quality and flux peak shape. Hence, a corrected K5 factor, which accounts for the axial heat flux distribution effect is suggested to correct these trends. It predicted the CHF power for the compiled data with an average error of 1.5% and a standard deviation of 10.3%, and also provides a reasonable prediction of CHF locations.
MODEL DE PREZENTARE A FLUXURILOR DE NUMERAR DEZVOLTAT PRIN METODA INDIRECTĂ
Daniel BRÎNDESCU – OLARIU
2014-01-01
Cu toate că în baza reglementărilor contabile în vigoare întreprinderile mici și mijlocii nu au obligativitatea întocmirii situației fluxurilor de numerar, aceasta poate fi utilă tuturor stakeholderilor. În lipsa unor module specifice în cadrul aplicațiilor informatice de evidență contabilă, elaborarea post-factum a situației fluxurilor de numerar prin metoda directă este extrem de dificilă. Modelele dezvoltate prin metoda indirectă rămân în aceste condiții o opțiune viabilă. Un număr ridicat...
A CHF Model in Narrow Gaps under Saturated Boiling
International Nuclear Information System (INIS)
Park, Suki; Kim, Hyeonil; Park, Cheol
2014-01-01
Many researchers have paid a great attention to the CHF in narrow gaps due to enormous industrial applications. Especially, a great number of researches on the CHF have been carried out in relation to nuclear safety issues such as in-vessel retention for nuclear power plants during a severe accident. Analytical studies to predict the CHF in narrow gaps have been also reported. Yu et al. (2012) developed an analytical model to predict the CHF on downward facing and inclined heaters based on the model of Kandlikar et al. (2001) for an upward facing heater. A new theoretical model is developed to predict the CHF in narrow gaps under saturated pool boiling. This model is applicable when one side of coolant channels or both sides are heated including the effects of heater orientation. The present model is compared with the experimental CHF data obtained in narrow gaps. A new analytical CHF model is proposed to predict CHF for narrow gaps under saturated pool boiling. This model can be applied to one-side or two-sides heating surface and also consider the effects of heater orientation on CHF. The present model is compared with the experimental data obtained in narrow gaps with one heater. The comparisons indicate that the present model shows a good agreement with the experimental CHF data in the horizontal annular tubes. However, it generally under-predicts the experimental data in the narrow rectangular gaps except the data obtained in the gap thickness of 10 mm and the horizontal downward facing heater
Mechanisms and predictions for subcooled flow boiling CHF
International Nuclear Information System (INIS)
Liu, Wei; Nariai, Hideki; Inasaka, Fujio
2000-01-01
Corresponding to the two kinds of flow pattern reported in literature for subcooled flow boiling, two kinds of CHF triggering mechanism are considered existing with working in different working scope. On the base of a criterion proposed recently by the present authors, subcooled flow boiling data firstly are categorized into two groups by judging whether the first kind or the second kind of flow pattern is established. Possible CHF triggering mechanisms and prediction methods for the two kinds of flow pattern condition are discussed. By considering both the flow pattern development and CHF triggering mechanism, a detailed data categorization is carried out. The corresponding CHF occurrence properties in different data groups are summarized. Parametric trends are reviewed for the first and second kind of data group working condition respectively. Mass flux, pressure, inlet subcooling and inner diameter show almost same effects in the two different working conditions, while the ratio of heated length to diameter's effects on CHF show to be different. Research for the L/D effect on the CHF transverse the interface of the different data groups is carried out. (author)
A Validation of Subchannel Based CHF Prediction Model for Rod Bundles
International Nuclear Information System (INIS)
Hwang, Dae-Hyun; Kim, Seong-Jin
2015-01-01
A large number of CHF data base were procured from various sources which included square and non-square lattice test bundles. CHF prediction accuracy was evaluated for various models including CHF lookup table method, empirical correlations, and phenomenological DNB models. The parametric effect of the mass velocity and unheated wall has been investigated from the experimental result, and incorporated into the development of local parameter CHF correlation applicable to APWR conditions. According to the CHF design criterion, the CHF should not occur at the hottest rod in the reactor core during normal operation and anticipated operational occurrences with at least a 95% probability at a 95% confidence level. This is accomplished by assuring that the minimum DNBR (Departure from Nucleate Boiling Ratio) in the reactor core is greater than the limit DNBR which accounts for the accuracy of CHF prediction model. The limit DNBR can be determined from the inverse of the lower tolerance limit of M/P that is evaluated from the measured-to-predicted CHF ratios for the relevant CHF data base. It is important to evaluate an adequacy of the CHF prediction model for application to the actual reactor core conditions. Validation of CHF prediction model provides the degree of accuracy inferred from the comparison of solution and data. To achieve a required accuracy for the CHF prediction model, it may be necessary to calibrate the model parameters by employing the validation results. If the accuracy of the model is acceptable, then it is applied to the real complex system with the inferred accuracy of the model. In a conventional approach, the accuracy of CHF prediction model was evaluated from the M/P statistics for relevant CHF data base, which was evaluated by comparing the nominal values of the predicted and measured CHFs. The experimental uncertainty for the CHF data was not considered in this approach to determine the limit DNBR. When a subchannel based CHF prediction model
Assessment of TRACE code against CHF experiments
International Nuclear Information System (INIS)
Audrius Jasiulevicius; Rafael Macian-Juan; Paul Coddington
2005-01-01
Full text of publication follows: This paper reports on the validation of the USNRC 'consolidate' code TRACE with data obtained during Critical Heat Flux (CHF) experiments in single channels and round and annular tubes. CHF is one of the key reactor safety parameters, because it determines the conditions for the onset of transition boiling in the core rod bundles, leading to the low heat transfer rates characteristics of the post-CHF heat transfer regime. In the context of the participation of PSI in the the International Programme for uncertainty analysis BEMUSE, we have carried out extensive work for the validation of some important TRACE models. The present work is aimed at assessing the range of validity for the CHF correlations and post-CHF heat transfer models currently included in TRACE. The heat transfer experiments selected for the assessment were performed at the Royal Institute of Technology (RIT) in Stockholm, Sweden and at the Atomic Energy Establishment in Winfrith, UK. The experimental investigations of the CHF and post-CHF heat transfer at RIT for flow of water in vertical tubes and annulus were performed at pressures ranging from 1 to 20 MPa and coolant mass fluxes from 500 to 3000 kg/m 2 s. The liquid was subcooled by 10 deg. C and 40 deg. C at the inlet of the test section. The experiments were performed on two different types of test sections. Experiments with uniformly heated single 7.0 m long tubes were carried out with three different inner tube diameters of 10, 14.9 and 24.7 mm. A series of experiments with non-uniform axial power distribution were also conducted in order to study the effect of the axial heat flux distribution on the CHF conditions in both 7.0 m long single tubes and 3.65 long annulus. Several different axial power profiles were employed with bottom, middle and top power peaks as well as the double-humped axial power profiles. In total more than 100 experiments with uniform axial heat flux distribution and several hundreds
MODEL DE PREZENTARE A FLUXURILOR DE NUMERAR DEZVOLTAT PRIN METODA INDIRECTĂ
Directory of Open Access Journals (Sweden)
Daniel BRÎNDESCU – OLARIU
2014-04-01
Full Text Available Cu toate că în baza reglementărilor contabile în vigoare întreprinderile mici și mijlocii nu au obligativitatea întocmirii situației fluxurilor de numerar, aceasta poate fi utilă tuturor stakeholderilor. În lipsa unor module specifice în cadrul aplicațiilor informatice de evidență contabilă, elaborarea post-factum a situației fluxurilor de numerar prin metoda directă este extrem de dificilă. Modelele dezvoltate prin metoda indirectă rămân în aceste condiții o opțiune viabilă. Un număr ridicat de astfel de modele prezintă însă deficiențe în materie de detaliere, omisiuni ale unor fluxuri importante sau erori conceptuale. Prezentul studiu propune un model de tablou al fluxurilor de numerar dezvoltat prin metoda indirectă. Acesta poate fi elaborat folosind exclusiv informațiile furnizate de bilanțul contabil și contul de profit și pierdere, oferind atât gradul ridicat de detaliere necesar în abordările post-factum, cât și acuratețea perfectă în explicarea variației trezoreriei de activ necesară în abordările previzionale.
Development and Assessment of a Bundle Correction Method for CHF
International Nuclear Information System (INIS)
Hwang, Dae Hyun; Chang, Soon Heung
1993-01-01
A bundle correction method, based on the conservation laws of mass, energy, and momentum in an open subchannel, is proposed for the prediction of the critical heat flux (CHF) in rod bundles from round tube CHF correlations without detailed subchannel analysis. It takes into account the effects of the enthalpy and mass velocity distributions at subchannel level using the first dericatives of CHF with respect to the independent parameters. Three different CHF correlations for tubes (Groeneveld's CHF table, Katto correlation, and Biasi correlation) have been examined with uniformly heated bundle CHF data collected from various sources. A limited number of GHE data from a non-uniformly heated rod bundle are also evaluated with the aid of Tong's F-factor. The proposed method shows satisfactory CHF predictions for rod bundles both uniform and non-uniform power distributions. (Author)
Fundamental approach to TRIGA steady-state thermal-hydraulic CHF analysis
International Nuclear Information System (INIS)
Feldman, E.
2008-01-01
Methods are investigated for predicting the power at which critical heat flux (CHF) occurs in TRIGA reactors that rely on natural convection for primary flow. For a representative TRIGA reactor, two sets of functions are created. For the first set, the General Atomics STAT code and the more widely-used RELAP5-3D code are each employed to obtain reactor flow rate as a function of power. For the second set, the Bernath correlation, the 2006 Groeneveld table, the Hall and Mudawar outlet correlation, and each of the four PG-CHF correlations for rod bundles are used to predict the power at which CHF occurs as a function of channel flow rate. The two sets of functions are combined to yield predictions of the power at which CHF occurs in the reactor. A combination of the RELAP5-3D code and the 2006 Groeneveld table predicts 67% more CHF power than does a combination of the STAT code and the Bernath correlation. Replacing the 2006 Groeneveld table with the Bernath CHF correlation (while using the RELAP5-3D code flow solution) causes the increase to be 23% instead of 67%. Additional RELAP5-3D flow-versus-power solutions obtained from Reference 1 and presented in Appendix B for four specific TRIGA reactors further demonstrates that the Bernath correlation predicts CHF to occur at considerably lower power levels than does the 2006 Groeneveld table. Because of the lack of measured CHF data in the region of interest to TRIGA reactors, none of the CHF correlations considered can be assumed to provide the definitive CHF power. It is recommended, however, to compare the power levels of the potential limiting rods with the power levels at which the Bernath and 2006 Groeneveld CHF correlations predict CHF to occur
The CHF enhancement on pool boiling using nano-fluids
International Nuclear Information System (INIS)
Chang, Won Joon; Jeong, Yong Hoon
2009-01-01
A increase of CHF was observed with nano-fluid. The addition of nano-particle helped to increase the wettability. This happens with the decrease in bubble diameter, breakup of bubbles and avoidance of bubble coalescence. CHF increase or decrease depends upon competition between high wettability and high instability. An optimum nano-fluid concentration is needed which must have high crystalline content. When the concentration reaches at a critical value, CHF will tend to a constant value. Deposition of nano-particles increasing the wettability and the rewetting are cause of CHF enhancement. It delay the growth of dry patch by increasing of wettability and lead to CHF enhancement. Now, we must define the wettability of nano-fluids. At case of nano-fluids using metallic particle, the explanation using contact angle using was reasonable. But, at case of nan-fluids using hydrophobic CNT, this explanation can't be acceptable. Moreover, at case of surfactant solution, contact angle was very low. But CHF enhancement was not great. So, wettability about nano-fluids must be defined anew for explanation of CHF enhancement. I suggest the extension of micro layer are acceptable concept for increasing wettability using nano-fluids
Pool Boiling CHF in Inclined Narrow Annuli
International Nuclear Information System (INIS)
Kang, Myeong Gie
2010-01-01
Pool boiling heat transfer has been studied extensively since it is frequently encountered in various heat transfer equipment. Recently, it has been widely investigated in nuclear power plants for application to the advanced light water reactors designs. Through the review on the published results it can be concluded that knowledge on the combined effects of the surface orientation and a confined space on pool boiling heat transfer is of great practical importance and also of great academic interest. Fujita et al. investigated pool boiling heat transfer, from boiling inception to the critical heat flux (CHF, q' CHF ), in a confined narrow space between heated and unheated parallel rectangular plates. They identified that both the confined space and the surface orientation changed heat transfer much. Kim and Suh changed the surface orientation angles of a downward heating rectangular channel having a narrow gap from the downward-facing position (180 .deg.) to the vertical position (90 .deg.). They observed that the CHF generally decreased as the inclination angle (θ ) increased. Yao and Chang studied pool boiling heat transfer in a confined heat transfer for vertical narrow annuli with closed bottoms. They observed that when the gap size ( s ) of the annulus was decreased the effect of space confinement to boiling heat transfer increased. The CHF was occurred at much lower value for the confined space comparing to the unconfined pool boiling. Pool boiling heat transfer in narrow horizontal annular crevices was studied by Hung and Yao. They concluded that the CHF decreased with decreasing gap size of the annuli and described the importance of the thin film evaporation to explain the lower CHF of narrow crevices. The effect of the inclination angle on the CHF on countercurrent boiling in an inclined uniformly heated tube with closed bottoms was also studied by Liu et al. They concluded that the CHF reduced with the inclination angle decrease. A study was carried out
Experimental Study on CHF in a Hemispherical Narrow Gap
International Nuclear Information System (INIS)
Jeong, J.H.; Park, R.J.; Kang, K.H.; Kim, S.B.; Kim, H.D.
1999-01-01
As a part of the SONATA-IV program, KAERI is conducting an experimental investigation of critical heat flux(CHF) in hemispherical narrow gaps. A visualization experiment, VISU-II, was done as the first step to get a visual observation of the flow behaviour inside a hemispherical gap and to understand the CHF-triggering mechanism. It was observed that the counter-current flow limitation (CCFL) phenomenon prevented water from wetting the heater surface and induced CHF. The CHFG (Critical Heat Flux in Gap) test is now being performed to measure the CHF and to investigate the inherent cooling mechanism in hemispherical narrow gaps. Temperature measurements over the heater surface show that the two-phase flow behaviour inside the gaps could be quite different from the other usual CHF experiments. The measured CHF points are lower than the predictions by existing empirical correlations based on the data measured with small-scale horizontal plates and vertical annulus. (authors)
Theoretical prediction method of subcooled flow boiling CHF
Energy Technology Data Exchange (ETDEWEB)
Kwon, Young Min; Chang, Soon Heung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
1999-12-31
A theoretical critical heat flux (CHF ) model, based on lateral bubble coalescence on the heated wall, is proposed to predict the subcooled flow boiling CHF in a uniformly heated vertical tube. The model is based on the concept that a single layer of bubbles contacted to the heated wall prevents a bulk liquid from reaching the wall at near CHF condition. Comparisons between the model predictions and experimental data result in satisfactory agreement within less than 9.73% root-mean-square error by the appropriate choice of the critical void fraction in the bubbly layer. The present model shows comparable performance with the CHF look-up table of Groeneveld et al.. 28 refs., 11 figs., 1 tab. (Author)
Theoretical prediction method of subcooled flow boiling CHF
Energy Technology Data Exchange (ETDEWEB)
Kwon, Young Min; Chang, Soon Heung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
1998-12-31
A theoretical critical heat flux (CHF ) model, based on lateral bubble coalescence on the heated wall, is proposed to predict the subcooled flow boiling CHF in a uniformly heated vertical tube. The model is based on the concept that a single layer of bubbles contacted to the heated wall prevents a bulk liquid from reaching the wall at near CHF condition. Comparisons between the model predictions and experimental data result in satisfactory agreement within less than 9.73% root-mean-square error by the appropriate choice of the critical void fraction in the bubbly layer. The present model shows comparable performance with the CHF look-up table of Groeneveld et al.. 28 refs., 11 figs., 1 tab. (Author)
Influence of stiffness on CHF for horizontal tubes under LPLF conditions
Energy Technology Data Exchange (ETDEWEB)
Baburajan, P.K. [Nuclear Safety Analysis Division, AERB, Niyamak Bhavan, 400094 (India); Bisht, Govind Singh [Department of Mechanical Engineering, IIT Bombay, 400076 (India); Gaikwad, Avinash J. [Nuclear Safety Analysis Division, AERB, Niyamak Bhavan, 400094 (India); Prabhu, S.V., E-mail: svprabhu@iitb.ac.in [Department of Mechanical Engineering, IIT Bombay, 400076 (India)
2014-10-01
Highlights: • Effect of stiffness on the CHF in horizontal tube under LPLF conditions is studied. • CHF increases with the increase in stiffness. • Correlation for the prediction of CHF as a function of stiffness is developed. • Correlation for mass flux at CHF in terms of stiffness and initial mass flux is given. • RELAP5 is capable of predicting the effect of stiffness on CHF. - Abstract: Studies reported in the past on critical heat flux (CHF) are mostly limited to vertical flow, large channel diameter, high pressure and high mass flux. Since horizontal flow is commonly encountered in boiler tubes, refrigerating equipments and nuclear reactor fuel channels (PHWR), there is a need to understand horizontal flow CHF, generate sufficient experimental database and to develop reliable predictive method. Few studies are reported on the effect of upstream flow restrictions on flow instabilities and CHF. The present work investigates the effect of upstream flow restriction on CHF in horizontal flow at near atmospheric pressure conditions. In the present study, stiffness is defined as the ratio of upstream flow restriction pressure drop to the test section pressure drop. The classification of a flow boiling system as soft or stiff on the basis of quantification of the stiffness is attempted. Experimental data shows an increase in the CHF with the increase in the stiffness for a given initial mass flux. A correlation for the prediction of CHF under various stiffness conditions is developed. A correlation is suggested to predict the mass flux at CHF as a function of stiffness and initial mass flux. Modeling and transient analysis of the stiffness effect on CHF is carried out using the thermal hydraulic system code RELAP5. The predicted phenomena are in agreement with the experimental observations.
Assessment of CHF characteristics at subcooled conditions for the CANFLEX bundle
International Nuclear Information System (INIS)
Onder, E.N.; Leung, L.K.H.
2013-01-01
Boiling-Length-Average (BLA) Critical Heat Flux (CHF) values for the CANFLEX bundle at cross-sectional average subcooled conditions have been evaluated using the ASSERT-PV subchannel code. The predicted BLA CHF values supplement experimental BLA CHF values obtained with full-scale bundle simulators at saturated conditions in developing a BLA CHF correlation applicable over the interested range of cross-sectional average thermodynamic quality in regional overpower protection (ROP) trip and safety analyses. The BLA CHF correlation exhibits similar characteristics to those observed in tubes at subcooled and saturated conditions. Applying this correlation has led to similar prediction accuracy in dryout power to that using the BLA CHF-data-based correlation at saturated conditions. However, it provides improved prediction accuracy in dryout power at dryout conditions near saturation compared to the BLA CHF-data-based correlation (which tends to underpredict the dryout power)
Neurohumoral blockade in CHF management
Directory of Open Access Journals (Sweden)
Roland Willenbrock
2000-03-01
Full Text Available Is heart failure an endocrine disease? Historically, congestive heart failure (CHF has often been regarded as a mechanical and haemodynamic condition. However, there is now strong evidence that the activation of neuroendocrine systems, like the renin-angiotensin-aldosterone system (RAAS and sympathetic nervous system, as well as the activation of natriuretic peptides, endothelin and vasopressin, play key roles in the progression of CHF. In this context, agents targeting neurohormones offer a highly rational approach to CHF management, with ACE inhibitors, aldosterone antagonists and beta-adrenergic blockade improving the prognosis for many patients. Although relevant improvements in clinical status and survival can be achieved with these drug classes, mortality rates for patients with CHF are still very high. Moreover, most patients do not receive these proven life-prolonging drugs, partially due to fear of adverse events, such as hypotension (with ACE inhibitors, gynaecomastia (with spironolactone and fatigue (with beta-blockers.New agents that combine efficacy with better tolerability are therefore needed. The angiotensin II type 1 (AT1-receptor blockers have the potential to fulfil both these requirements, by blocking the deleterious cardiovascular and haemodynamic effects of angiotensin II while offering placebo-like tolerability. As shown with candesartan, AT1-receptor blockers also modulate the levels of other neurohormones, including aldosterone and atrial natriuretic peptide (ANP. Combined with its tight, long-lasting binding to AT1-receptors, this characteristic gives candesartan the potential for complete blockade of the RAAS-neurohormonal axis, along with the great potential to improve clinical outcomes.
Accuracy improvement of SPACE code using the optimization for CHF subroutine
International Nuclear Information System (INIS)
Yang, Chang Keun; Kim, Yo Han; Park, Jong Eun; Ha, Sang Jun
2010-01-01
Typically, a subroutine to calculate the CHF (Critical Heat Flux) is loaded in code for safety analysis of nuclear power plant. CHF subroutine calculates CHF phenomenon using arbitrary condition (Temperature, pressure, flow rate, power, etc). When safety analysis for nuclear power plant is performed using major factor, CHF parameter is one of the most important factor. But the subroutines used in most codes, such as Biasi method, etc., estimate some different values from experimental data. Most CHF subroutines in the codes could predict only in their specification area, such as pressure, mass flow, void fraction, etc. Even though the most accurate CHF subroutine is used in the high quality nuclear safety analysis code, it is not assured that the valued predicted values by the subroutine are acceptable out of their application area. To overcome this hardship, various approaches to estimate the CHF have been examined during the code developing stage of SPACE. And the six sigma technique was adopted for the examination as mentioned this study. The objective of this study is to improvement of CHF prediction accuracy for nuclear power plant safety analysis code using the CHF database and Six Sigma technique. Through the study, it was concluded that the six sigma technique was useful to quantify the deviation of prediction values to experimental data and the implemented CHF prediction method in SPACE code had well-predict capabilities compared with those from other methods
Theoretical and experimental investigations of CHF in round tubes and rod bundles
International Nuclear Information System (INIS)
Hwang, Dae Hyun
1994-02-01
A knowledge of the condition leading to critical heat flux (CHF) is of great importance in the design of nuclear reactors. Although many efforts have been devoted to the subject of CHF during the last few decades, information on the burnout phenomenon at low velocity condition is very limited. Furthermore, in most cases, the applicable range of a bundle CHF correlation is restricted to a narrow region mainly due to the limitation of the CHF data base used in the correlation development. In view of these points, theoretical and experimental investigations are performed in this study for round tubes and rod bundles. A CHF prediction model for low velocity conditions is proposed throughout the assessment of CHF data from various sources with mass velocities less than 500 kg/m 2 s. The CHF data base is classified into seven groups with respect to the flow pattern characteristics at CHF conditions. CHF data for each group is analyzed by several CHF prediction models including; the flooding correlations, the flow regime transition criteria, the complete evaporation model, and the empirical correlations. At zero inlet flow or extremely low mass velocity conditions, the flooding correlation can be used for predicting CHF employing appropriate constant. In the slug or churn-turbulent flow regime, CHF seems to occur at the annular flow transition conditions. When CHF occurs at the annular flow region, the empirical correlation such as AECL CHF lookup table gives accurate predictions except for the ranges where density-wave instability is expected. A phenomenological model for the prediction of dryout locations under flooding-limited CHF condition is developed based on the liquid film dryout model and the two-phase mixture level theory. The mass and energy conservation equations are applicable to the liquid film considering no entrainment of liquid droplets from the film region. The variation of the two-phase mixture level after the onset of flooding is calculated based on
Comparison of BIASI and Columbia CHF correlations using BODYFIT-2PE
International Nuclear Information System (INIS)
Chen, B.C.J.; Chien, T.H.; Sha, W.T.; Kim, J.H.
1984-01-01
This paper compares the BIASI critical heat flux (CHF) correlation with the Columbia CHF correlation by using both the homogeneous equilibrium two-phase model with algebraic slip and the drift flux model in BODYFIT-2PE. All calculations were compared with the GE 3 x 3 CHF experiment. This comparison serves as a qualification process for the CHF correlations in the framework of BODYFIT-2PE
Post CHF heat transfer and quenching
International Nuclear Information System (INIS)
Nelson, R.A.; Condie, K.G.
1980-01-01
This paper describes quantitatively new mechanisms in the post-CHF regime which provide understanding and predictive capability for several current two-phase forced convective heat transfer problems. These mechanisms are important in predicting rod temperature turnaround and quenching during the reflood phase of either a hypothetical loss-of-coolant accident (LOCA) or the FLECHT and Semiscale experiments. The mechanisms are also important to the blowdown phase of a LOCA or the recent Loss-of-Fluid Test (LOFT) experiments L2-2 and L2-3, which were 200% cold leg break transients. These LOFT experiments experienced total core quenching in the early part of the blowdown phase at high (1000 psia) pressures. The mechanisms are also important to certain pressurized water reactor (PWR) operational transients where the reactor may operate in the post-CHF regime for short periods of time. Accurate prediction of the post-CHF heat transfer including core quench during these transients is of prime importance to limit maximum cladding temperatures and prevent cladding deformation
International Nuclear Information System (INIS)
Hall, D.D.; Mudawar, I.
1996-01-01
A simple methodology for assessing the predictive ability of critical heat flux (CHF) correlations applicable to subcooled flow boiling in a uniformly heated vertical tube was developed. Popular correlations published in handbooks and review articles as well as the most recent correlations were analyzed with a database compiled by the authors. The PU-BTPFL CHF Database, which contains 29,718 CHF data points, is the largest collection of CHF data ever cited in the world literature. The parametric ranges of the CHF database are diameters from 0.3 to 45 mm, length-to-diameter ratios from 2 to 2484, mass velocities from 0.01 x 10 3 to 138 x 10 3 kg m -2 s -1 , pressures from 1 to 223 bars, inlet subcoolings from 0 to 347 C, inlet qualities from -2.63 to 0.00, outlet subcoolings from 0 to 305 C, outlet qualities from -2.13 to 1.00, and critical heat fluxes from 0.05 x 10 6 to 276 x 10 6 W m -2 . The database contained 4357 data points having a subcooled outlet condition at CHF. The correlation published in Caira et al. (1993) was the most accurate in both low and high mass velocity regions having been developed with a larger database than most correlations. In general, CHF correlations developed from data covering a limited range of flow conditions can not be extended to other flow conditions without much uncertainty. Subcooled flow boiling has great potential for accommodating the high heat fluxes in such diverse applications as fusion and fission reactors, manufacturing and materials processing, advanced space thermal management systems, accelerator targets, avionic cold plates, X-ray anodes, and high-density multi-chip modules in supercomputers and other modular electronics
Establishment and assessment of CHF data base for square-lattice rod bundles
International Nuclear Information System (INIS)
Hwang, Dae Hyun; Seo, K. W.; Kim, K. K.; Zee, S. Q.
2002-02-01
A CHF data base is constructed for square-lattice rod bundles, and assessed with various existing CHF prediction models. The CHF data base consists of 10725 data points obtained from 147 test bundles with uniform axial power distributions and 29 test bundles with non-uniform axial power distributions. The local thermal-hydraulic conditions in the subchannels are calculated by employing a subchannel analysis code MATRA. The influence of turbulent mixing parameter on CHF is evaluated quantitatively for selected test bundles with representative cross sectional configurations. The performance of various CHF prediction models including empirical correlations for round tubes or rod bundles, theoretical DNB models such as sublayer dryout model and bubble crowding model, and CHF lookup table for round tubes, are assessed for the localized rod bundle CHF data base. In view of the analysis result, it reveals that the 1995 AECL-IPPE CHF lookup table method is one of promising models in the aspect of the prediction accuracy and the applicable range. As the result of analysis employing the CHF lookup table for 9113 data points with uniform axial heat profile, the mean and the standard deviation of P/M are calculated as 1.003 and 0.115 by HBM, 1.022 and 0.319 by DSM respectively
Development of CHF models for inner and outer RPV gaps in a meltdown severe accident
International Nuclear Information System (INIS)
Wang, J.; Tian, W.X.; Feng, K.; Yu, H.X.; Zhang, Y.P.; Su, G.H.; Qiu, S.Z.
2013-01-01
Highlights: • A CHF model was developed to predict the CHF in hemispherical narrow gap. • The computed result was validated by the test data of Park and Köhler. • An analytical CHF model was developed to predict the CHF on the outer surface of the lower head. • The predicted CHF was compared with the experimental data of ULPU-V. • Two CHF models developed for the inner and outer CHF predict the CHF well. - Abstract: During a severe accident, the core melt relocates in the lower head and a hemispherical narrow gap may appear between the crust and the lower head because of the different material expansion ratio. The existence of this gap is very important to the integrity of the lower head. Based on the counter current flow limitation (CCFL) between the vapor phase and the liquid phase, a CHF model was developed to predict the CHF in hemispherical narrow gap. The CHF model developed was validated by the test data of Park and Köhler. The effect of key parameters, including the system pressure, radius of melt, and gap size, on the CHF were investigated. And the TMI-2 accident was also calculated by using the CHF formula. Moreover, based on the interface separation model, an analytical CHF model was developed to predict the CHF on the outer surface of the lower head. The predicted CHF was compared with the experimental data of ULPU-V. It indicated that the CHF models developed for the inner and outer CHF could predict the CHF well
Fundamental approach to TRIGA steady-state thermal-hydraulic CHF analysis
International Nuclear Information System (INIS)
Feldman, E.E.
2008-01-01
Methods are investigated for predicting the power at which critical heat flux (CHF) occurs in TRIGA reactors that rely on natural convection for primary flow. For a representative TRIGA reactor, two sets of functions are created. For the first set, the General Atomics STAT code and the more widely-used RELAP5-3D code are each employed to obtain reactor flow rate as a function of power. For the second set, the Bernath correlation, the 2006 Groeneveld table, the Hall and Mudawar outlet correlation, and each of the four PG-CHF correlations for rod bundles are used to predict the power at which CHF occurs as a function of channel flow rate. The two sets of functions are combined to yield predictions of the power at which CHF occurs in the reactor. A combination of the RELAP5-3D code and the 2006 Groeneveld table predicts 67% more CHF power than does a combination of the STAT code and the Bernath correlation. (author)
Prediction of critical heat flux in fuel assemblies using a CHF table method
Energy Technology Data Exchange (ETDEWEB)
Chun, Tae Hyun; Hwang, Dae Hyun; Bang, Je Geon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Baek, Won Pil; Chang, Soon Heung [Korea Advance Institute of Science and Technology, Taejon (Korea, Republic of)
1998-12-31
A CHF table method has been assessed in this study for rod bundle CHF predictions. At the conceptual design stage for a new reactor, a general critical heat flux (CHF) prediction method with a wide applicable range and reasonable accuracy is essential to the thermal-hydraulic design and safety analysis. In many aspects, a CHF table method (i.e., the use of a round tube CHF table with appropriate bundle correction factors) can be a promising way to fulfill this need. So the assessment of the CHF table method has been performed with the bundle CHF data relevant to pressurized water reactors (PWRs). For comparison purposes, W-3R and EPRI-1 were also applied to the same data base. Data analysis has been conducted with the subchannel code COBRA-IV-I. The CHF table method shows the best predictions based on the direct substitution method. Improvements of the bundle correction factors, especially for the spacer grid and cold wall effects, are desirable for better predictions. Though the present assessment is somewhat limited in both fuel geometries and operating conditions, the CHF table method clearly shows potential to be a general CHF predictor. 8 refs., 3 figs., 3 tabs. (Author)
Prediction of critical heat flux in fuel assemblies using a CHF table method
Energy Technology Data Exchange (ETDEWEB)
Chun, Tae Hyun; Hwang, Dae Hyun; Bang, Je Geon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Baek, Won Pil; Chang, Soon Heung [Korea Advance Institute of Science and Technology, Taejon (Korea, Republic of)
1997-12-31
A CHF table method has been assessed in this study for rod bundle CHF predictions. At the conceptual design stage for a new reactor, a general critical heat flux (CHF) prediction method with a wide applicable range and reasonable accuracy is essential to the thermal-hydraulic design and safety analysis. In many aspects, a CHF table method (i.e., the use of a round tube CHF table with appropriate bundle correction factors) can be a promising way to fulfill this need. So the assessment of the CHF table method has been performed with the bundle CHF data relevant to pressurized water reactors (PWRs). For comparison purposes, W-3R and EPRI-1 were also applied to the same data base. Data analysis has been conducted with the subchannel code COBRA-IV-I. The CHF table method shows the best predictions based on the direct substitution method. Improvements of the bundle correction factors, especially for the spacer grid and cold wall effects, are desirable for better predictions. Though the present assessment is somewhat limited in both fuel geometries and operating conditions, the CHF table method clearly shows potential to be a general CHF predictor. 8 refs., 3 figs., 3 tabs. (Author)
CHF Enhancement by Surface Patterning based on Hydrodynamic Instability Model
Energy Technology Data Exchange (ETDEWEB)
Seo, Han; Bang, In Cheol [UNIST, Ulsan (Korea, Republic of)
2015-05-15
If the power density of a device exceeds the CHF point, bubbles and vapor films will be covered on the whole heater surface. Because vapor films have much lower heat transfer capabilities compared to the liquid layer, the temperature of the heater surface will increase rapidly, and the device could be damaged due to the heater burnout. Therefore, the prediction and the enhancement of the CHF are essential to maximizing the efficient heat removal region. Numerous studies have been conducted to describe the CHF phenomenon, such as hydrodynamic instability theory, macrolayer dryout theory, hot/dry spot theory, and bubble interaction theory. The hydrodynamic instability model, proposed by Zuber, is the predominant CHF model that Helmholtz instability attributed to the CHF. Zuber assumed that the Rayleigh-Taylor (RT) instability wavelength is related to the Helmholtz wavelength. Lienhard and Dhir proposed a CHF model that Helmholtz instability wavelength is equal to the most dangerous RT wavelength. In addition, they showed the heater size effect using various heater surfaces. Lu et al. proposed a modified hydrodynamic theory that the Helmholtz instability was assumed to be the heater size and the area of the vapor column was used as a fitting factor. The modified hydrodynamic theories were based on the change of Helmholtz wavelength related to the RT instability wavelength. In the present study, the change of the RT instability wavelength, based on the heater surface modification, was conducted to show the CHF enhancement based on the heater surface patterning in a plate pool boiling. Sapphire glass was used as a base heater substrate, and the Pt film was used as a heating source. The patterning surface was based on the change of RT instability wavelength. In the present work the study of the CHF was conducted using bare Pt and patterned heating surfaces.
Conformational analysis of capsaicin using 13C, 15N MAS NMR, GIAO DFT and GA calculations
Siudem, Paweł; Paradowska, Katarzyna; Bukowicki, Jarosław
2017-10-01
Capsaicin produced by plants from genus Capsicum exerts multiple pharmacological effects and has found applications in food and pharmaceutical industry. The alkaloid was studied by a combined approach: solid-state NMR, GA conformational search and GIAO DFT methods. The 13C CPMAS NMR spectra were recorded using variable contact time and dipolar dephasing experiments. The results of cross-polarization (CP) kinetics, such as TCP values and long T1ρH (100-200 ms), indicated that the capsaicin molecule is fairly mobile, especially at the end of the aliphatic chain. The15N MAS NMR spectrum showed one narrow signal at -255 ppm. Genetic algorithm (GA) search with multi modal optimization was used to find low-energy conformations of capsaicin. Theoretical GIAO DFT calculations were performed using different basis sets to characterize five selected conformations. 13C CPMAS NMR was used as a validation method and the experimental chemical shifts were compared with those calculated for selected stable conformers. Conformational analysis suggests that the side chain can be bent or extended. A comparison of the experimental and the calculated chemical shifts indicates that solid capsaicin does not have the same structure as those established by PWXRD.
Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli
Energy Technology Data Exchange (ETDEWEB)
Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki
2001-09-01
Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions.
Experimental study on the CHF in uniformly and non-uniformly heated vertical annuli
International Nuclear Information System (INIS)
Chun, Se Young; Moon, Sang Ki; Chung, Heung June; Park, Jong Kuk; Kim, Bok Deuk; Youn, Young Jung; Chung, Moon Ki
2001-09-01
Up to now, KAERI has performed critical heat flux experiments in water under zero-flow and low-flow conditions using a RCS CHF loop facility with uniformly and non-uniformly heated vertical annulus. Since the existing CHF experiments were mainly performed under low-pressure conditions, we performed the CHF experiment to investigate the pressure effect on the CHF under zero-flow and low-flow conditions for a wide range of system pressures. Also, two vertical annuli with the same geometry have been used to investigate the axial heat flux distributions on the CHF. This report summarizes the experimental results and provides the CHF data that can be used for the development for CHF correlation and a thermal hydraulic analysis code. The CHF data have been collected for system pressures ranging from 0.57 to 15.15 MPa, mass flux 0 and from 200 to 650 kg/m2s, inlet subcooling from 75 to 360 kJ/kg and exit quality from 0.07 to 0.57. At low-flow conditions, the total number of data are 242 and 290 with uniformly heated- and non-uniformly heated test sections, respectively. 41 and 94 CHF data are generated with uniformly heated- and non-uniformly heated test sections, respectively, in zero-flow CHF experiments that are performed by blocking test section bottoms. The CHF experiment result shows that the effects of system pressure, mass flux and inlet subcooling are consistent with conventional understandings and similar to those for round tubes. The behavior of the CHF is relatively complex at low pressures. Also, the effects of axial heat flux profile are large at low-pressure conditions
Pool boiling CHF enhancement by micro/nanoscale modification of zircaloy-4 surface
International Nuclear Information System (INIS)
Ahn, Ho Seon; Lee, Chan; Kim, Hyungdae; Jo, HangJin; Kang, SoonHo; Kim, Joonwon; Shin, Jeongseob; Kim, Moo Hwan
2010-01-01
Consideration of the critical heat flux (CHF) requires difficult compromises between economy and safety in many types of thermal systems, including nuclear power plants. Much research has been directed towards enhancing the CHF, and many recent studies have revealed that the significant CHF enhancement in nanofluids is due to surface deposition of nanoparticles. The surface deposition of nanoparticles influenced various surface characteristics. This fact indicated that the surface wettability is a key parameter for CHF enhancement and so is the surface morphology. In this study, surface wettability of zircaloy-4 used as cladding material of fuel rods in nuclear power plants was modified using surface treatment technique (i.e. anodization). Pool boiling experiments of distilled water on the prepared surfaces was conducted at atmospheric and saturated conditions to examine effects of the surface modification on CHF. The experimental results showed that CHF of zircaloy-4 can be significantly enhanced by the improvement in surface wettability using the surface modification, but only the wettability effect cannot explain the CHF increase on the treated zircaloy-4 surfaces completely. It was found that below a critical value of contact angle (10 o ), micro/nanostructures created by the surface treatment increased spreadability of liquid on the surface, which could lead to further increase in CHF even beyond the prediction caused only by the wettability improvement. These micro/nanostructures with multiscale on heated surface induced more significant CHF enhancement than it based on the wettability effect, due to liquid spreadability.
Assessment of CHF characteristics at subcooled conditions for the CANDU CANFLEX bundle
International Nuclear Information System (INIS)
Onder, E.N.; Leung, L.K.H.
2011-01-01
An analysis has been performed to assess the Critical Heat Flux (CHF) characteristics for the CANFLEX bundle at subcooled conditions. CHF characteristics for CANDU bundles have been established from experiments using full-scale bundle simulators. These experiments covered flow conditions of interest to normal operation and postulated loss-of-flow and small break loss-of-coolant accidents. Experimental CHF values obtained from these experiments were applied to develop correlations for analyses of regional overpower protection and safety trips. These correlations are applicable to the saturated region in the reference uncrept channel and the slightly subcooled region in postulated high-creep channels. Expanding the CHF data to subcooled conditions facilitates the evaluation of the margin to dryout at upstream bundle locations, even though dryout occurrences are not anticipated there. In view of the lack of experimental data, the ASSERT-PV subchannel code has been applied to establish CHF values at low qualities and high subcoolings (thermodynamic qualities corresponding to -25%). These CHF values have been applied to extend the CHF correlation to the highly subcooled conditions. (author)
Autosomal recessive polycystic kidney disease and congenital hepatic fibrosis (ARPKD/CHF)
Energy Technology Data Exchange (ETDEWEB)
Turkbey, Baris; Choyke, Peter L. [National Institutes of Health, Molecular Imaging Program, National Cancer Institute, Bethesda, MD (United States); Ocak, Iclal [National Institutes of Health, Molecular Imaging Program, National Cancer Institute, Bethesda, MD (United States); University of Pittsburgh Medical Center, Department of Radiology, Pittsburgh, PA (United States); Daryanani, Kailash [National Institutes of Health, Clinical Center, Department of Radiology, Bethesda, MD (United States); Font-Montgomery, Esperanza; Lukose, Linda; Bryant, Joy; Tuchman, Maya; Gahl, William A. [National Institutes of Health, National Human Genome Research Institute, Medical Genetics Branch, Bethesda, MD (United States); Mohan, Parvathi [George Washington University, Department of Pediatric Gastroenterology, Washington, DC (United States); Heller, Theo [National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD (United States); Gunay-Aygun, Meral [National Institutes of Health, National Human Genome Research Institute, Medical Genetics Branch, Bethesda, MD (United States); National Institutes of Health, Intramural Program, Office of Rare Diseases, Office of the Directors, Bethesda, MD (United States)
2009-02-15
ARPKD/CHF is an inherited disease characterized by non-obstructive fusiform dilatation of the renal collecting ducts leading to enlarged spongiform kidneys and ductal plate malformation of the liver resulting in congenital hepatic fibrosis. ARPKD/CHF has a broad spectrum of clinical presentations involving the kidney and liver. Imaging plays an important role in the diagnosis and follow-up of ARPKD/CHF. Combined use of conventional and high-resolution US with MR cholangiography in ARPKD/CHF patients allows detailed definition of the extent of kidney and hepatobiliary manifestations without requiring ionizing radiation and contrast agents. (orig.)
A theoretical model for flow boiling CHF from short concave heaters
International Nuclear Information System (INIS)
Galloway, J.E.; Mudawar, I.
1995-01-01
Experiments were performed to enable the development of a new theoretical mode for the enhancement in CHF commonly observed with flow boiling on concave heater as compared to straight heaters. High-speed video imaging and photomicrography were employed to capture the trigger mechanism for CHF each type heater. A wavy vapor layer was observed to engulf the heater surface in each case, permitting liquid access to the surface only in regions where depressions (troughs) in the liquid vapor interface made contact with the surface. CHF in each case occurred when the pressure force exerted upon the wavy vapor-liquid inter ace in the contact region could no longer overcome the momentum of the vapor produced in these regional. Shorter interfacial wavelengths with greater curvature were measured on the curve, heater than on the straight heater, promoting a greater pressure force on the wave interface and a corresponding increase in CHF for the curved heater. A theoretics. CHF model is developed from these observations, based upon a new theory for hydrodynamic instability, along a curved interface. CHF data are predicted with good accuracy for both heaters. 23 refs., 9 figs
International Nuclear Information System (INIS)
Chun, S. Y.; Mun, S. K.; Park, J. K.; Yang, S. K.; Jung, M. K.
1999-01-01
The relationship between the boiling length and the CHF in annulus geometry with uniformly heated rod has been studied. In this study the CHF data under pressure of 0.57∼15.01 MPa, flow rate of 200∼650 kg/m 2 s, inlet subcooling of 85∼353 kJ/kg and exit quality of 0.106∼0.536 have been applied. As a result of examining the flow pattern over the heated section, all of the CHF data were the dryout type CHF in annular flow and the locations of the churn to annular flow transition moved down stream of the heated section with increasing the pressure. The effect of pressure on the boiling length under the CHF conditions showed the trends similar to the effect of pressure on the CHF. The relationship between the non-dimensional CHF, q CHF and mass flux taking into account of the boiling length, G ( L h / L B ) indicated the linear relationship without scatter and regardless of pressure and inlet subcooling. The CHF calculated by using the relationship between the non-dimensionless CHF, q CHF and mass flux, G ( L h / L B ) predicted very well the experimental CHF data with the pressure dependence
ESTIMASI ALIRAN AIR LINDI TPA BANTAR GEBANG BEKASI MENGGUNAKAN METODA SP
Directory of Open Access Journals (Sweden)
Syamsu Rosid
2012-02-01
Full Text Available Air lindi merupakan limbah sampah organik yang biasanya diproduksi dari sampah rumah tangga. Pencemaran air tanah (groundwater oleh air lindi menjadi ancaman yang serius bagi masyarakat. Penduduk Bantar Gebang, Bekasi merasa terancam kehidupannya dengan adanya tempat pembuangan akhir (TPA sampah yang dikirim dari DKI Jakarta. Beberapa penduduk di sekitar TPA mengeluhkan bahwa air sumurnya agak bau dan tidak lagi terasa segar. Untuk mengetahui seperti apa polusi air lindi yang terjadi, ke arah mana dan sudah sejauh mana sebarannya, dan memetakan daerah resiko tinggi terkena polusi maka telah dilakukan pengukuran geolistrik metoda self potential (SP di sebelah Tenggara dan Selatan daerah TPA Bantar Gebang, Bekasi. Dari data SP diketahui bahwa aliran air tanah bawah permukaan di daerah tersebut berarah Selatan ke Utara. Meskipun lokasi TPA berada di Utara daerah penelitian, limbah air lindi diduga telah mencemari air tanah bawah permukaan hingga radius ratusan meter dari lokasi TPA. Penyebaran air limbah ini diperkirakan melalui proses osmosis, mekanisme kapilaritas dan proses elektrokinetik.  Kata kunci: air lindi, metoda SP, TPA Bantar Gebang.
Post-CHF heat transfer during steady-state and transient conditions
International Nuclear Information System (INIS)
Fung, K.K.
1978-06-01
This review extends previous reviews of steady-state post-CHF literature by Groeneveld, Gardiner, and Fung by including more recent data. A review of the literature on transient post-CHF data is also included by extending the work of Yadigaroglu
A study on the CHF enhancement of pool boiling using nano-fluids
International Nuclear Information System (INIS)
Chang, Won Joon
2009-02-01
The understanding of CHF phenomenon and an accurate prediction of the CHF condition are important for safe and economic design of many heat transfer units including nuclear reactors, fossil fuel boilers, fusion reactors, electronic chips, etc. The phenomenon has been investigated extensively over the world since Nukiyama (1934) first characterized it. In particular, a large amount of significant work has been done during the last four decades with the development of water cooled nuclear reactors. The wettability of the heated surface under pool boiling of surfactant solutions and nano-fluids has been investigated. Tri-sodium phosphate (TSP, Na 3 PO 4 ) solutions and Aluminum oxide nano-fluids were prepared for experiments. Contact angles of pure water and the solutions on the quenched surface and fresh surface were measured. Surfaces deposited TSP and nano-particle could affect surface energy of the strips and enhance hydrophilicity of the surfaces. Several implications of the experimental results on the pool boiling CHF model and CHF enhancement using TSP and NF were discussed. A increase of CHF was observed with nano-fluid. The addition of nano-particle helped to increase the wettability by reducing the surface tension. This happens with the decrease in bubble diameter, breakup of bubbles and avoidance of bubble coalescence. CHF increase or decrease depends upon competition between high wettability and high instability. An optimum nano-fluid concentration is needed which must have high crystalline content. When the concentration reaches at a critical value, CHF will tend to a constant value. As the results of previous study, surface tension effect the results of CHF. And it is same to nano-fluids, because surface tension change the dynamics of mixture fluids at two phase and means the instability of thermal hydraulics. Contact angle which be in the limelight at recent research means wettability of heated surface. However, in case of nano-fluids, both are
Application of artificial neural networks in analysis of CHF experimental data in round tubes
International Nuclear Information System (INIS)
Huang Yanping; Chen Bingde; Lang Xuemei; Wang Xiaojun; Shan Jianqiang; Jia Dounan
2004-01-01
Artificial neural networks (ANNs) are applied successfully to analyze the critical heat flux (CHF) experimental data from some round tubes in this paper. A set of software adopting artificial neural network method for predicting CHF in round tube and a set of CHF database are gotten. Comparing with common CHF correlations and CHF look-up table, ANN method has stronger ability of allow-wrong and nice robustness. The CHF predicting software adopting artificial neural network technology can improve the predicting accuracy in a wider parameter range, and is easier to update and to use. The artificial neural network method used in this paper can be applied to some similar physical problems. (authors)
Prediction of sodium critical heat flux (CHF) in annular channel using grey systems theory
International Nuclear Information System (INIS)
Zhou Tao; Su Guanghui; Zhang Weizhong; Qiu Suizheng; Jia Dounan
2001-01-01
Using grey systems theory and experimental data obtained from sodium boiling test loop in China, the grey mutual analysis of some parameters influencing sodium CHF is carried out, and the CHF values are predicted by GM(1, 1) model. The GM(1, h) model is established for CHF prediction, and the predicted CHF values are good agreement with the experimental data
Simulation of CHF Condition using an Electroplating System
Energy Technology Data Exchange (ETDEWEB)
Ohk, Seung-Min; Park, Hae-Kyun; Chung, Bum-Jin [Kyung Hee University, Yongin (Korea, Republic of)
2016-10-15
Heat transfer is enhanced when the bubbles are generated on the heated surface at the nucleate boiling regime since vigorous mixing of the liquid occurs near the heated surface due to the buoyancy force of the bubbles. As this phenomenon intensified, vapor film can be formed on the heated surface and it impairs heat transfer disturbing the heat exchange between the surface and the bulk liquid. And thus, the heat flux has the certain maximum value. This maximum value, Critical Heat Flux (CHF) is generally exhibits in the pool boiling condition in non-film boiling mode. Actually, the higher heat flux could be generated at the film boiling mode with extremely high surface temperature, which may unendurable for the system structure. CHF phenomena is simulated by hydrogen gas using electroplating system in mass transfer experiment. Vapor behavior on mass transfer experiment was visualized, and it was similar to that of on the heat transfer. CHF value was simulated by hydrogen gas with isovolumetric concept. Thus, virtual heat flux was estimated by mass flux, which is a non-heating process. Difference of gas density from heat transfer and mass transfer systems were considered and revised for the simulated heat flux. Despite of the simple parametric analysis, estimated CHF value of this study was 6.6 times smaller than Zuber's.
An experimental study of flow boiling chf with porous surface coatings and surfactant solutions
International Nuclear Information System (INIS)
Sarwar, Mohammad Sohail
2007-02-01
The boiling crisis or critical heat flux (CHF) phenomenon is an enormously studied topic of the boiling heat transfer. The great interest in the CHF is due to practical motives, since it is desirable to design an equipment (heat exchanger or boiler, etc) to operate at as high a heat flux as possible with optimum heat transfer rates but without the risk of physical burnout. This study consists of two parts of flow boiling CHF experiment: with porous surface coated tubes and by using surfactant solutions as working fluid. In first part, the effect of micro- and nano-porous inside surface coated vertical tubes on the CHF was determined for flow boiling of water in vertical round tubes at atmospheric pressure. CHF was measured for a smooth and three different coated tubes, at mass fluxes of 100∼300 kg/m 2 s and two inlet subcooling temperatures (50 .deg. C and 75 .deg. C). Greater CHF enhancement was found with microporous coatings. Al 2 O 3 microporous coatings with particle size <10 μm and coating thickness of 50 μm showed the best CHF enhancement. The maximum increase in the CHF was about 25% for microporous Al 2 O 3 . A wettability test was performed to study the physical mechanism of increase of CHF with microporous coated surfaces and contact angle was measured for smooth and coated surfaces. Pressure drop measurements were also performed across the coated tubes using the DP-cell apparatus. In second part, surfactant effect on the CHF was determined for water flow boiling at atmospheric pressure in a closed loop filled with solution of tri-sodium phosphate (TSP, Na 3 PO 4 ·12H 2 O). The TSP is usually added to the containment sump water to adjust pH level during accident in nuclear power plants. The CHF was measured for four different surfactant solutions of water in vertical tubes, at different mass fluxes (100 ∼ 500 kg/m 2 s) and two inlet subcooling temperatures (50 .deg. C and 75 .deg. C). Surfactant solutions in the range of 0.05%∼0.2% at low mass
Critical heat flux (CHF) phenomenon on a downward facing curved surface
Energy Technology Data Exchange (ETDEWEB)
Cheung, F.B.; Haddad, K.H.; Liu, Y.C. [Pennsylvania State Univ., University Park, PA (United States). Dept. of Mechanical Engineering
1997-06-01
This report describes a theoretical and experimental study of the boundary layer boiling and critical heat flux phenomena on a downward facing curved heating surface, including both hemispherical and toroidal surfaces. A subscale boundary layer boiling (SBLB) test facility was developed to measure the spatial variation of the critical heat flux and observe the underlying mechanisms. Transient quenching and steady-state boiling experiments were performed in the SBLB facility under both saturated and subcooled conditions to obtain a complete database on the critical heat flux. To complement the experimental effort, an advanced hydrodynamic CHF model was developed from the conservation laws along with sound physical arguments. The model provides a clear physical explanation for the spatial variation of the CHF observed in the SBLB experiments and for the weak dependence of the CHF data on the physical size of the vessel. Based upon the CHF model, a scaling law was established for estimating the local critical heat flux on the outer surface of a heated hemispherical vessel that is fully submerged in water. The scaling law, which compares favorably with all the available local CHF data obtained for various vessel sizes, can be used to predict the local CHF limits on large commercial-size vessels. This technical information represents one of the essential elements that is needed in assessing the efficacy of external cooling of core melt by cavity flooding as a severe accident management strategy. 83 figs., 3 tabs.
Critical heat flux (CHF) phenomenon on a downward facing curved surface
International Nuclear Information System (INIS)
Cheung, F.B.; Haddad, K.H.; Liu, Y.C.
1997-06-01
This report describes a theoretical and experimental study of the boundary layer boiling and critical heat flux phenomena on a downward facing curved heating surface, including both hemispherical and toroidal surfaces. A subscale boundary layer boiling (SBLB) test facility was developed to measure the spatial variation of the critical heat flux and observe the underlying mechanisms. Transient quenching and steady-state boiling experiments were performed in the SBLB facility under both saturated and subcooled conditions to obtain a complete database on the critical heat flux. To complement the experimental effort, an advanced hydrodynamic CHF model was developed from the conservation laws along with sound physical arguments. The model provides a clear physical explanation for the spatial variation of the CHF observed in the SBLB experiments and for the weak dependence of the CHF data on the physical size of the vessel. Based upon the CHF model, a scaling law was established for estimating the local critical heat flux on the outer surface of a heated hemispherical vessel that is fully submerged in water. The scaling law, which compares favorably with all the available local CHF data obtained for various vessel sizes, can be used to predict the local CHF limits on large commercial-size vessels. This technical information represents one of the essential elements that is needed in assessing the efficacy of external cooling of core melt by cavity flooding as a severe accident management strategy. 83 figs., 3 tabs
A study on the effect of the CHF correlations to the LOCA analysis
International Nuclear Information System (INIS)
Kim, Ho Kee
1998-02-01
The critical heat flux (CHF) is a major parameter which determines the cooling performance and therefore the prediction of CHF is of importance for the design and safety analysis in boiling systems; such as nuclear reactors, conventional boilers, and other various two-phase flow systems. Until now, many CHF correlations have been developed and for the actual design a correlation has been selected in consideration of its characteristics. For the analysis of Loss of Coolant Accident (LOCA) in a Nuclear Power Plant, which shows the drastic parameters change during the system transient, a correlation having a reasonable degree of accuracy over a wide range is preferred, rather than that having accuracy for a specific range. It is required to have tangible insight about the effects of the CHF correlation to the LOCA analysis for the purpose of computer code development and nuclear regulation. The related research is further recommended. The purpose of this research is to obtain an insight and/or intuition about the above effect and to evaluate the selected CHF correlations. To achieve these purposes LOCA is analysed for the UL-JIN 3 and 4 nuclear power plant, the Korea Standard Type Nuclear Power Plant and the Loss of Flow Test (LOFT) L2-5 experiment is simulated using the RELAP5/MOD3.1 computer code for each selected CHF correlation. The selected correlations are the AECL-UO Lookup Table, adapted in RELAP5 code; the K110 CHF correlation, developed by KAERI; and the original W-3 CHF correlation, developed by L.S. Tong. LOFT is also simulated using the AECL-UO Lookup Table having the CHF multiplication factors 0.5 and 1.5, and then compared with the result of the original Lookup Table and the experiment result. In the LOCA analysis, the CHF correlations affect the magnitude of peak cladding temperatures, but does not seriously affect the occurrence points of time. The effect of each CHF correlation to the fuel cladding temperature behavior becomes apparent at the end of
CHF correlations related to the core cooling of a research reactor
International Nuclear Information System (INIS)
Mishima, K.; Nishihara, H.; Shibata, T.
1984-01-01
Critical heat flux (CHF) at low flow condition can become important in a research reactor under a number of accident conditions. Regardless of the initial stages of these accidents, a similar condition, which is basically the decay heat removal by natural convection boiling, can develop. Under such conditions, burnout may occur even at a very low heat flux. In view of this, the low-flow CHF has been studied to provide a better understanding of the dryout behavior. The experimental results under atmospheric pressure indicate that a CHF can occur at much lower heat flux than pool-boiling CHF or than predicted by the conventional correlations. This fact indicates that a special care should be taken in analyzing the boiling phenomenon which occurs when the coolant flow is very low in a low pressure system. (author)
Atmospheric chemistry of CH3CHF2 (HFC-152a)
DEFF Research Database (Denmark)
Taketani, Fumikazu; Nakayama, Tomoki; Takahashi, Kenshi
2005-01-01
Smog chamber/Fourier transform infrared (FTIR) and laser-induced fluorescence (LIF) spectroscopic techniques were used to study the atmospheric degradation of CH3CHF2. The kinetics and products of the Cl(2P(3/2)) (denoted Cl) atom- and the OH radical-initiated oxidation of CH3CHF2 in 700 Torr of ...
Tutoring szkolny jako koncepcja i metoda wsparcia rozwoju ucznia
Drozd, Ewa; Zembrzuska, Agnieszka
2013-01-01
Celem artykułu jest dokonanie opisu koncepcji i metody tutoringu szkolnego w odniesieniu do kilkuletnich doświadczeń programu Kolegium Tutorów realizowanego przy wsparciu lokalnych władz oświatowych. Tutoring ma korzenie akademickie jako zindywidualizowana metoda pracy studenta z profesorem, jego istotą jest otwarcie na potrzeby drugiego człowieka i wspieranie w rozwoju. Można wskazać kilka źródeł filozoficznych, które dookreślają czym współcześnie jest tutoring (sokratejski dialog, filozofia...
Audit calculation and comments on a new CHF correlation
Energy Technology Data Exchange (ETDEWEB)
Auh, Geun Sun [Korea Institute of Nuclear Safety, Daejon (Korea, Republic of); Hwang, Dae Hyun [Korea Atomic Energy Research Institute, Daejon (Korea, Republic of)
2008-10-15
An audit calculation was conducted for a local parameter CHF correlation which was intended for the thermal hydraulic design calculations of a new type of fuel assembly, named 17x17 type ACE7. The proposed empirical correlation calculates the CHF as a function of local conditions in a rod bundle which were evaluated by the subchannel analysis code THINC. The CHF data base for this correlation consisted of 4 test bundles with a total of 295 data points. Independent audit calculation was performed in order to substantiate the analyses results for the proposed correlation. Total 295 calculations were performed with a subchannel code MATRA and the results were compared with the results of THINC calculations. A new feature of the proposed correlation is a correction factor for axially non uniform power shapes. The proposed correction factor model contends a decrease of upstream memory effect with a decrease of the grid spacing. The physical background as well as the CHF data base supporting the magnitude of the correction factor was closely investigated. From the results of the investigation, the applicability limitations such as 3.5% penalty factor on the DNBR and 17x17 type ACE7 fuel assembly application only were self imposed on the proposed correlation.
Directory of Open Access Journals (Sweden)
Armasastra Bahar
2015-10-01
Full Text Available Gingivitis sebagai salah satu kelainan jaringan penyangga gigi telah diketahui disebabkan karena kebersihan mulut yang tidak baik dan berkaitan dengan kebiasaan dan cara menyikat gigi yang tidak memadai. Di samping itu telah banyak pula laporan yang mengatakan bahwa terjadinya gingivitis juga berhubungan dengan peningkatan hormon kelamin steroid darah seperti pada kehamilan, menstruasi dan pada pengguna kontrasepsi hormonal.Dalam pemeriksaan yang dilakukan pada beberapa wanita pengguna kontrasepsi oral di Puskesmas Serpong ditemukan kelainan gingivitis.Pada penderita tersebut dilakukan pemeriksaan intraoral dan Occult Blood Test untuk memperkuat pemeriksaan apakah keadaan gingivitisnya memerlukan terapi lebih lanjut. Setelah dilakukan penambalan gigi yang merupakan keluhan utama penderita datang ke BKIA, dilakukan usaha untuk menanggulangi gingivitis yang ada berupa penerangan tentang faktor-faktor yang menjadi penyebab gingivitis dan instruksi cara menyikat gigi dengan metoda "Toothpick brushing". Evaluasi yang dilakukan pada minggu II dan III, memperlihatkan hasil yang baik, nilai PI, PBI dan OBT menurun dibandingkan dengan nilai awal yang telah dilakukan.Pada kunjungan pada minggu III dilakukan pembersihan karang gigi. Menyikat gigi dengan metoda "Toothpick brushing" memperlihatkan hasil yang baik dalam memperbaiki kelainan gingivitis.
Experimental study on CHF characteristics of water-TiO2 nano-fluids
International Nuclear Information System (INIS)
Kim, Hyung Dae; Kim Moo Hwan; Kim, Jeong Bae
2006-01-01
CHF characteristics of nano-fluids were investigated with different volumetric concentrations of TiO 2 nanoparticles. Pool boiling experiments indicated that the application of nano-fluids, instead of pure water, as a cooling liquid significantly increased the CHF. SEM (Scanning Electron Microscope) observations subsequent to the pool boiling experiments revealed that nanoparticles were coated on the heating surface during pool boiling of nano-fluids. In order to investigate the roles of nanoparticles in CHF enhancement of nano-fluids, pool boiling experiments were performed using (a) a nanoparticle-coated heater, prepared by pool boiling of nano-fluids, immersed in pure water and (b) a nanoparticle-coated heater immersed in nano-fluids. The results demonstrated two different roles of nanoparticles in CHF enhancement using nano-fluids: the effect of nanoparticles coated on the heater surface and the effect of nanoparticles suspended in nano-fluids
Energy Technology Data Exchange (ETDEWEB)
Choi, Young Jae; Kam, Dong Hoon; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)
2015-10-15
This study may give overall trends of CHF enhancement in the subcooled boiling region. In our experiment, subcooled flow boiling CHF enhancement phenomena in water and nano-coated surface was investigated in mass flux from 1000 to 5000 kg/m{sup 2}s. CHF enhancement of nanoparticles coated tube in DI water increased as exit quality get bigger at same massflux. Various methods to improve CHF characteristics are introduced, especially nanofluids are used for enhancing the CHF. Nanofluids is a colloidal suspension that nanoparticles are mixed with basic fluid. Normally the use of nanofluids as working fluid improves the flow boiling CHF characteristics. Lee et al. already researched the CHF characteristics using nanofluids. As exit quality increased from 0.07 to 0.74, CHF enhancement gradually decreased and approached zero. CHF enhancement was observed when exit quality was low and a DNB-like thermal crisis occurred. But CHF enhancement didn't occur for high exit quality, but LFD-type thermal crisis occurred. Because LFD phenomena are nearly unaffected by the surface conditions, CHF enhancement is not expected for annular flow with high exit quality. Kim et al. performed flow boiling CHF enhancement at subcooled region using alumina-water, zinc-oxide-water and diamond-water nanofluids. The CHF was enhanced by increasing wettability from nanoparticle deposition. CHF enhancement occurred in high mass flux (2000-2500 kg/m{sup 2}s), but CHF enhancement didn't occur in low mass flux (1500 kg/m{sup 2}s). The amount of nanoparticle deposition on each tube can be different during experiments by the several conditions such as deposition time, mass flux and heat flux. So, before the nanofluid experiment conducted, all tube are deposited in same condition of heat flux, concentration and time.
CHF enhancement through Pressurized Intermediate Layer in IVR-ERVC Strategy
International Nuclear Information System (INIS)
Park, Seong Dae; Bang, In Cheol
2014-01-01
The molten fuel is sequentially relocated to bottom of reactor vessel. In-vessel retention through the external reactor vessel cooling (IVR-ERVC) strategy has been adapted to some reactors at this situation in order to prevent the progression of an accident. The limitation of IVR-ERVC strategy is CHF phenomenon on the outer wall of reactor vessel. The boiling is main heat transfer mode to remove decay heat between the reactor vessel and the coolant surrounding the reactor vessel. Heated molten radioactive material is leaked. The fuel coolant interaction (FCI) phenomenon could cause the steam explosion in a state of fully flooding condition. Therefore, the CHF should be enhanced in order to be a successful IVR-ERVC strategy. Related studies were performed to confirm the CHF limit with UPLU, SBLB, KAIST and UNIST test facilities The recommendations to increase CHF include coating some materials on the vessel outer surface, increasing the reactor cavity flood level and streamlining the gap between the vessel and the vessel insulation. Recently, flooding the liquid metal is proposed to prevent the boiling itself. In this work, the effects of pressurized liquid layer inserted between the reactor vessel and flooded coolant was studied. Suitable reactor geometry was also presented to apple this concept. Generally, CHF is increased as high pressure was applied until about 1/3 of critical pressure. The limit of IVR-ERVC strategy could overcome by using pressurized intermediate layer. The CFD analysis was performed to confirm the feasibility of pressurized IVR-ERVC system. There are enough thermal margins for due to the enlarged heat transfer area and the convection heat transfer
CHF enhancement through Pressurized Intermediate Layer in IVR-ERVC Strategy
Energy Technology Data Exchange (ETDEWEB)
Park, Seong Dae; Bang, In Cheol [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)
2014-05-15
The molten fuel is sequentially relocated to bottom of reactor vessel. In-vessel retention through the external reactor vessel cooling (IVR-ERVC) strategy has been adapted to some reactors at this situation in order to prevent the progression of an accident. The limitation of IVR-ERVC strategy is CHF phenomenon on the outer wall of reactor vessel. The boiling is main heat transfer mode to remove decay heat between the reactor vessel and the coolant surrounding the reactor vessel. Heated molten radioactive material is leaked. The fuel coolant interaction (FCI) phenomenon could cause the steam explosion in a state of fully flooding condition. Therefore, the CHF should be enhanced in order to be a successful IVR-ERVC strategy. Related studies were performed to confirm the CHF limit with UPLU, SBLB, KAIST and UNIST test facilities The recommendations to increase CHF include coating some materials on the vessel outer surface, increasing the reactor cavity flood level and streamlining the gap between the vessel and the vessel insulation. Recently, flooding the liquid metal is proposed to prevent the boiling itself. In this work, the effects of pressurized liquid layer inserted between the reactor vessel and flooded coolant was studied. Suitable reactor geometry was also presented to apple this concept. Generally, CHF is increased as high pressure was applied until about 1/3 of critical pressure. The limit of IVR-ERVC strategy could overcome by using pressurized intermediate layer. The CFD analysis was performed to confirm the feasibility of pressurized IVR-ERVC system. There are enough thermal margins for due to the enlarged heat transfer area and the convection heat transfer.
Enhanced CHF with Bubble Cutter and Artificial Flow in Nuclear Plants
International Nuclear Information System (INIS)
Jung, Chan Hee; Suh, Kune Y.
2013-01-01
The main goal of this paper is to body out the notions of forced convection system for enhanced local streams and air bubbles cutting (and/or pushing, breaking) system to explain how CHF can be improved and how those bubble cutter systems are applicable to NPPs. In this paper, the bubble cutter system and an artificial flow system which can cut (and/or push and break) air bubbles is bodied out to drag bubbles. It also make the surface wet condition of heated surfaces and improve heat transfer and prevent on creation of bubbles on the heated surfaces or heat exchangers or reactor cores. Namely, concepts and application methods to increase CHF are presented for NPPs. Enhanced critical heat flux (CHF) is one of our prospective aims for nuclear power plants (NPPs). Previous work has studied the flow boiling CHF enhancement with surfactant solutions under atmospheric pressure because surfactant solutions or surface conditions have an effect on the behavior of occurrence air bubbles on a heated surface. Another possible improvement is to improve efficiency of heat transfer or to body out some types of bubble breaking (and/or pushing, breaking) systems or an artificial flow of fluid that can tear off air bubbles or push hot liquid and bubbles on a surface of heater. During this study, it will be observed that those possible structures can elicit increased CHF by means of maintenance of contact with a coolant such as water
Interval and continuous exercise enhances aerobic capacity and hemodynamic function in CHF rats
Directory of Open Access Journals (Sweden)
Ramiro B. Nunes
2015-08-01
Full Text Available OBJECTIVE: The aim of the present study was to compare the effects of continuous versus interval aerobic exercise training on hemodynamic parameters, cardiac remodeling, and maximal exercise capacity (MEC in chronic heart failure (CHF rats.METHOD: Twenty-four male Wistar rats were subjected to myocardial infarction (MI surgery. Five weeks post MI, the animals were assigned to one of three groups: sedentary group (CHF-Sed, n=8, aerobic continuous training group (CHF-ACT, n=8, and aerobic interval training group (CHF-AIT, n=8. Treadmill training was performed five times a week for 8 weeks (ACT: 50 min/day at 15 m/min and AIT: 40 min/day with 8 min of warm-up at 10 m/min and exercise at 15 m/min 4×4 min interspersed with 4×4 min at 23 m/min. MEC was evaluated pre and post exercise program.RESULTS: Left ventricular end-diastolic pressure (LVEDP, left ventricular mass/body mass ratio (LVM:BM, and total collagen volume fraction were lower in the trained groups compared with the sedentary group, but no difference was found between the trained groups. Systolic ventricular pressure (SVP and maximum positive derivative of LV pressure (+dP/dtmax were higher in the trained groups, but CHF-ACT showed higher +dP/dtmax compared to CHF-AIT. Both training regimens were able to increase MEC. However, the aerobic interval training was superior for improving MEC.CONCLUSION: Aerobic training is an important intervention to improve cardiac function and remodeling and physical capacity in CHF rats. Interval training is a potential strategy to maximize the results, but exercise type and intensity are still topics to be explored.
CHF enhancement in pool boiling of nanofluid : effect of nanoparticle-coating on heating surface
International Nuclear Information System (INIS)
Kim, Hyung Dae; Kim, Moo Hwan
2005-01-01
Recently researches to enhance CHF using the nanofluid, a new kind of heat transfer fluid in which nano-particles are uniformly and stably dispersed, were attempted. You showed that nanofluid, containing only 0.005 g/l of alumina nanoparticle, make the dramatic increase (∼200%) in CHF in pool boiling at the pressure of 2.89 psia (Tsat=60 .deg. C). They concluded that the abnormal CHF enhancement of nanofluid cannot be explained with any existing models of CHF. Vassallo performed the experimental studies on pool boiling heat transfer in water-SiO 2 nanofluid under atmospheric pressure. They showed a remarkable increase in CHF for nanofluid and also found that the stable film boiling at temperatures close to the melting point of the boiling surface are achievable with the nanofluid. After the experiments, they observed that the formation of the thin silica coating on the wire heater was occurred. This paper focuses on the experimental study of the effect of nanoparticle-coating on CHF enhancement in pool boiling of nanofluid. In this regard, pool boiling CHF values are measured and compared (a) from bare heater immersed in nanofluid and (b) from nanoparticle-coated heater, which is generated by deposition of suspended nanoparticles during pool boiling of nanofluid, immersed in pure water, and (c) from nanoparticle-coated heater immersed in nanofluid. And the microstructure of each heating surface is investigated from photography taken using SEM
Analytical prediction of CHF by FIDAS code based on three-fluid and film-dryout model
International Nuclear Information System (INIS)
Sugawara, Satoru
1990-01-01
Analytical prediction model of critical heat flux (CHF) has been developed on the basis of film dryout criterion due to droplets deposition and entrainment in annular mist flow. Critical heat flux in round tubes were analyzed by the Film Dryout Analysis Code in Subchannels (FIDAS) which is based on the three-fluid, three-field and newly developed film dryout model. Predictions by FIDAS were compared with the world-wide experimental data on CHF obtained in water and Freon for uniformly and non-uniformly heated tubes under vertical upward flow condition. Furthermore, CHF prediction capability of FIDAS was compared with those of other film dryout models for annular flow and Katto's CHF correlation. The predictions of FIDAS are in sufficient agreement with the experimental CHF data, and indicate better agreement than the other film dryout models and empirical correlation of Katto. (author)
Evaluation of CHF experimental data for non-square lattice 7-rod bundles
Energy Technology Data Exchange (ETDEWEB)
Hwang, Dae Hyun; Yoo, Y. J.; Kim, K. K.; Zee, S. Q
2001-01-01
A series of CHF experiments are conducted for 7-rod hexagonal test bundles in order to investigate the CHF characteristics of self-sustained square finned (SSF) rod bundles. The experiments are performed in the freon-loop and water-loop located at IPPE in Russia, and 609 data of freon-12 and 229 data of water are obtained from 7 kinds of test bundles classified by the combination of heated length and axial/radial power distributions. As the result of the evaluation of four representative CHF correlations, the EPRI-1 correlation reveals good prediction capability for SSF test bundles. The inlet parameter CHF correlation suggested by IPPE calculates the mean and the standard deviation of P/M for uniformly heated test bundles as 1.002 and 0.049, respectively. In spite of its excellent accuracy, the correlation has a discontinuity point at the boundary between the low velocity and high velocity conditions. KAERI's inlet parameter correlation eliminates this defect by introducing the complete evaporation model at low velocity condition, and calculates the mean and standard deviation of P/M as 0.095 and 0.062 for uniformly heated 496 data points, respectively. The mean/standard deviation of local parameter CHF correlations suggested by IPPE and KAERI are evaluated as 1.023/0.178 and 1.002/0.158, respectively. The inlet parameter correlation developed from uniformly heated test bundles tends to under-predict CHF about 3% for axially non-uniformly heated test bundles. On the other hand, the local parameter correlation reveals large scattering of P/M, and requires re-optimization of the correlation for non-uniform axial power distributions. As the result of the analysis of experimental data, it reveals that the correction model of axial power shapes suggested by IPPE is applicable to the inlet parameter correlations. For the test bundle of radial non-uniform power distribution, the physically unexpected results are obtained at some experimental conditions. In addition
An experimental study of forced convective flow boiling CHF in nanofluid
International Nuclear Information System (INIS)
Ahn, Hoseon; Kim, Seontae; Jo, Hangjin; Kim, Dongeok; Kang, Soonho; Kim, Moohwan
2008-01-01
Recently the enhancement of CHF (critical heat flux) in nanofluids under the pool boiling condition is known as a result of nanoparticle deposition on the heating surface. The deposition phenomenon of nanoparticles on the heating surface is induced dominantly by the vigorous boiling on the heating surface. Considering the importance of flow boiling conditions in various practical heat transfer applications, an experimental study was performed to verify whether or not the enhancement of CHF in nanofluids exists in a forced convective flow boiling condition. The nanofluid used in this research was Al 2 O 3 -water dispersed by the ultra-sonic vibration method in very low concentration (0.01% Vol). A heater specimen was made of a copper block easily detachable to look into the surface condition after the experiment. The heating method was a thermal-heating made with a conductive material. The flow channel took a rectangular type (10mm x 10mm) and had a length of 1.2 m to assure a hydrodynamically fully-developed region. In result, CHF in the nanofluid under the forced convective flow boiling condition has been enhanced distinctively along with the effect of flow rates. To reason the CHF increase in the nanofluids, the boiling surface was investigated thoroughly with the SEM image. (author)
International Nuclear Information System (INIS)
Mejia-Urueta, Rafael; Mestre-Quintero, Kleyber; Vivas-Reyes, Ricardo
2011-01-01
Perfluorinated organic compounds (POCs), such as perfluorooctanesulfonate (PFOS) and perfluoroalkylsulfonamide (PFASA) are compounds that have recently attracted considerable attention worldwide because of its high persistence and wide distribution in the environment. Among the spectroscopic methods used to study the PFASA, 19 F nuclear magnetic resonance (NMR 19 F) is very effective, due to its ability to determine concentrations of PFASA in biological samples and measure pollution in water samples. For this reason, a theoretical study of the properties of 19 F NMR was performed. In this study we have determined the shielding constant (σ) for different fluorine nucleus of the 18 molecules under study, using density functional theory (DFT) and GIAO method with the B3PW91/6-31+G(d,p) level of calculation. The σ calculations were made at vacuum and in presence of a solvent. The values of chemical shifts (δ), were also calculated in a different level of theory. The best results were obtained with the level of calculation DFT-GIAO/B3PW91/6-31+G(d,p) by considering the solvent such as dimethylsulfoxide (DMSO), chloroform (CHCl 3 ), acetone (CH 3 COCH 3 ) and methanol (CH 3 OH). The results were interpreted in terms of calculated hardness at DFT/B3PW91/6-31+G(d, p) level. The behaviour of the hardness was higher in the molecules of four carbons PFASA than eight carbons. This explain theoretically resistance of four carbons PFAS to be transformed into perfluorobutanesulfonate (PFBS). (author)
Impact of the New Generation Reconstituted Surfactant CHF5633 on Human CD4+ Lymphocytes.
Directory of Open Access Journals (Sweden)
Markus Fehrholz
Full Text Available Natural surfactant preparations, commonly isolated from porcine or bovine lungs, are used to treat respiratory distress syndrome in preterm infants. Besides biophysical effectiveness, several studies have documented additional immunomodulatory properties. Within the near future, synthetic surfactant preparations may be a promising alternative. CHF5633 is a new generation reconstituted synthetic surfactant preparation with defined composition, containing dipalmitoyl-phosphatidylcholine, palmitoyl-oleoyl-phosphatidylglycerol and synthetic analogs of surfactant protein (SP- B and SP-C. While its biophysical effectiveness has been demonstrated in vitro and in vivo, possible immunomodulatory abilities are currently unknown.The aim of the current study was to define a potential impact of CHF5633 and its single components on pro- and anti-inflammatory cytokine responses in human CD4+ lymphocytes.Purified human CD4+ T cells were activated using anti CD3/CD28 antibodies and exposed to CHF5633, its components, or to the well-known animal-derived surfactant Poractant alfa (Curosurf®. Proliferative response and cell viability were assessed using flow cytometry and a methylthiazolyldiphenyltetrazolium bromide colorimetric assay. The mRNA expression of IFNγ, IL-2, IL-17A, IL-22, IL-4, and IL-10 was measured by quantitative PCR, while intracellular protein expression was assessed by means of flow cytometry.Neither CHF5633 nor any of its phospholipid components with or without SP-B or SP-C analogs had any influence on proliferative ability and viability of CD4+ lymphocytes under the given conditions. IFNγ, IL-2, IL-17A, IL-22, IL-4, and IL-10 mRNA as well as IFNγ, IL-2, IL-4 and IL-10 protein levels were unaffected in both non-activated and activated CD4+ lymphocytes after exposure to CHF5633 or its constituents compared to non-exposed controls. However, in comparison to Curosurf®, expression levels of anti-inflammatory IL-4 and IL-10 mRNA were
CHF considerations for highly moderated 100% MOX fuels PWRs
Energy Technology Data Exchange (ETDEWEB)
Saphier, D.; Raymond, P. [CEA Saclay, DMT/SERMA/LETR, Gif-sur-Yvette (France)
1995-09-01
A feasibility study on using 100% MOX fuel in a PWR with increased moderating ratio, RMA, was initiated. In the proposed design all the parameters were chosen identical to the French 1450MW PWR, except the fuel pin diameter which was reduced to achieve higher moderating ratios, V{sub M}/V{sub F}, where V{sub M} and V{sub F} are the moderator and fuel volume respectively. Moderating ratios from 2 to 4 were considered. In the present study the thermal-hydraulic feasibility of using fuel assemblies with smaller diameter fuel pins was investigated. The major design constrain in this study was the critical heat flux (CHF). In order to maintain the fuel pin integrity under nominal operating and transient conditions, the minimum DNBR, (Departure from Nucleate Boiling Ratio given by CHF/q{close_quotes}{sub local}, where q{close_quotes}{sub local} is the local heat flux), has to be above a given value. The limitations of the existing CHF correlations for the present study are outlined. Two designs based on the conventional 17x17 fuel assembly and on the advanced 19x19 assembly meeting the MDNBR criteria and satisfying the control margin requirements, are proposed.
CHF multiplier of subcooled flow boiling for non-uniform heating conditions in swirl tube
International Nuclear Information System (INIS)
Inasaka, F.; Nariai, H.
1994-01-01
The high heat flux components of fusion reactors, such as divertor plates and beam dumps of neutral beam injectors, are estimated to be subjected to very high heat loads more than 10 MW/m 2 . Critical heat flux (CHF), which determines the upper limit of heat removal, is one of the most important problems in designing cooling systems. For practical applications in cooling systems, subcooled flow boiling in water combined with swirl-flow in tubes with internal twisted tape is thought to be the most superior for CHF characteristics in fusion reactor components, heat by irradiation comes in from one side of the wall, and cooling channel is then under circumferentially non-uniform heating condition. Authors have conducted the experiments on the CHF with internal twisted tapes under circumferentially non-uniform heating conditions and showed that when the intensity of non-uniformity increased, q cH (peak heat flux at burnout under nonuniform heating condition) in tube with internal twisted tape increased above the q c,unif (CHF under uniform heating condition), though the average qualities were the same for both cases. They also showed that this CHF enhancement was not seen in smooth tubes without tape under the same average qualities
Energy Technology Data Exchange (ETDEWEB)
Mejia-Urueta, Rafael; Mestre-Quintero, Kleyber; Vivas-Reyes, Ricardo, E-mail: rvivasr@unicartagena.edu.co [Grupo de Quimica Cuantica y Teorica, Facultad de Ciencias Exactas y Naturales, Universidad de Cartagena, Cartagena (Colombia)
2011-09-15
Perfluorinated organic compounds (POCs), such as perfluorooctanesulfonate (PFOS) and perfluoroalkylsulfonamide (PFASA) are compounds that have recently attracted considerable attention worldwide because of its high persistence and wide distribution in the environment. Among the spectroscopic methods used to study the PFASA, {sup 19}F nuclear magnetic resonance (NMR {sup 19}F) is very effective, due to its ability to determine concentrations of PFASA in biological samples and measure pollution in water samples. For this reason, a theoretical study of the properties of {sup 19}F NMR was performed. In this study we have determined the shielding constant ({sigma}) for different fluorine nucleus of the 18 molecules under study, using density functional theory (DFT) and GIAO method with the B3PW91/6-31+G(d,p) level of calculation. The {sigma} calculations were made at vacuum and in presence of a solvent. The values of chemical shifts ({delta}), were also calculated in a different level of theory. The best results were obtained with the level of calculation DFT-GIAO/B3PW91/6-31+G(d,p) by considering the solvent such as dimethylsulfoxide (DMSO), chloroform (CHCl{sub 3}), acetone (CH{sub 3}COCH{sub 3}) and methanol (CH{sup 3}OH). The results were interpreted in terms of calculated hardness at DFT/B3PW91/6-31+G(d, p) level. The behaviour of the hardness was higher in the molecules of four carbons PFASA than eight carbons. This explain theoretically resistance of four carbons PFAS to be transformed into perfluorobutanesulfonate (PFBS). (author)
International Nuclear Information System (INIS)
Green, W.J.
1982-03-01
An examination of more than 5000 sets of experimental data for critical heat flux (CHF) in uniformly heated vertical tubes internally cooled by high pressure water has shown that the CHF correlation proposed in Part 1 of this work is accurate for water at pressures up to approximately 17 MPa, provided that minor modifications are made to the Prandtl number index, and the saturation boiling length function. For pressures greater than 17 MPa, CHF values calculated from the correlation are increasingly lower than the experimental data, particularly at low saturation boiling length ratios ( -1 m -2 or thermal equilibrium exit qualities are less than 0.1
Implementation of the Westinghouse WRB-2 CHF correlation in VIPRE
International Nuclear Information System (INIS)
Klasmier, L.K.; Haksoo Kim
1992-01-01
As part of the reload transient and thermal-hydraulic methods development effort within Commonwealth Edison Company (CECo), the WRB-2 critical heat flux (CHF) correlation has been implemented into the VIPRE-01 thermal-hydraulic analysis code to support Westinghouse 17X17 Vantage 5 fuel. CECo is in the process of switching from Westinghouse optimized fuel assembly (OFA) fuel to Vantage 5 fuel at CECo's six pressurized water reactors. CECo performs the neutronic portion of the reload analysis using Westinghouse's ANC/PHOENIX. The transient and thermal-hydraulic analysis will be performed using the RETRAN and VIPRE codes once the Nuclear Regulatory Commission has completed their review of CECo methodology. Previously, CECo had implemented and received NRC approval to use the Westinghouse WRB-1 CHF correlation in the VIPRE-01 code to support 15X15 and 17X17 OFA fuel designs. Since the WRB-1 CHF correlation is not applicable for 17X17 Vantage 5 fuel, it was necessary to implement the WRB-2 CHF correlation in the VIPRE code. The WRB-2 correlation was developed by Westinghouse using a database applicable to 17X17 OFA and Vantage 5 fuel and the THINC thermal-hydraulic analysis code. At CECo, the WRB-2 correlation had been implemented into VIPRE-01/MOD-02. The results produced at CECo have been statistically compared to those produced by Westinghouse. Owen's method was used to determine the VIPRE/WRB-02 thermal limit. The thermal limit for 17X17 OFA and Vantage 5 fuel use in VIPRE/WRB-2 is in excellent agreement with the value calculated by Westinghouse using THINC/WRB-2
International Nuclear Information System (INIS)
Mishima, K.; Nishihara, H.
1985-01-01
Critical heat flow (CHF) at low flow condition can become important in an MTR-type research reactor under a number of accident conditions. Regardless of the initial stages of these accidents, a condition which is basically the decay heat removal by natural convention boiling can develop. Under such conditions, burnout may occur even at a very low heat flow. In view of this, the CHF at low-flow-rate and low-pressure conditions has been studied for water flowing in thin rectangular channels. Experiments were carried out with two types of rectangular test sections, namely, the one heated from one wide side and the other heated from two opposite sides. In order to observe the effects of gravity, CHF was measured both in upflow and downflow. The CHF at complete bottom blockage was also studied. The results indicate that burnout can occur at a much lower heat flux than pool-boiling CHF or than predicted by the conventional correlations. There was observed a minimum CHF at complete bottom blockage and at very low downflow. The low CHF at very low downflow appears to be due to the stagnation of the bubble in the heated section. This fact indicates that special care should be taken in analyzing the boiling phenomenon which occurs when the coolant flow is very low in a low pressure system. (author)
Energy Technology Data Exchange (ETDEWEB)
Park, Seong Dae; Bang, In Cheol, E-mail: icbang@unist.ac.kr
2013-12-15
Highlights: • We investigate CHF limits of graphene oxide nanofluid for IVR-ERVC. • Graphene oxide nanofluid enhanced CHF up to about 20%. • CHF enhancement can be explained by the improved thermal activity. - Abstract: External reactor vessel cooling for in-vessel retention of corium is an important concept to mitigate the consequences of a severe accident by flooding the reactor cavity. Although this system has some merits, it is restricted by the capacity of heat removal through the nucleate boiling on the outer surface of the reactor. In this study, the graphene oxide (GO) nanofluid at 0.0001 vol% was used to enhance the critical heat flux (CHF). The CHF tests were conducted with a closed-loop facility. Test section simulated the reactor vessel of APR-1400 with a small scale. The test results show about ∼20% enhancement of CHF at 50 and 100 kg/m{sup 2} s under a 10 K subcooling condition. It means that the additional thermal margin could be acquired by just adding the GO nanoparticles to the flooding water without severe economic concerns. It is also found that this CHF enhancement is caused by coating the graphene oxide nanoparticles on the heated surface. However, the sessile drop tests on the coated heater surface show that the wettability of GO coated surface is not improved. The results of IR thermography show that one of the promising reasons is the change of thermal activity due to the coated GO nanoparticles on the heated surface.
International Nuclear Information System (INIS)
Park, Seong Dae; Bang, In Cheol
2013-01-01
Highlights: • We investigate CHF limits of graphene oxide nanofluid for IVR-ERVC. • Graphene oxide nanofluid enhanced CHF up to about 20%. • CHF enhancement can be explained by the improved thermal activity. - Abstract: External reactor vessel cooling for in-vessel retention of corium is an important concept to mitigate the consequences of a severe accident by flooding the reactor cavity. Although this system has some merits, it is restricted by the capacity of heat removal through the nucleate boiling on the outer surface of the reactor. In this study, the graphene oxide (GO) nanofluid at 0.0001 vol% was used to enhance the critical heat flux (CHF). The CHF tests were conducted with a closed-loop facility. Test section simulated the reactor vessel of APR-1400 with a small scale. The test results show about ∼20% enhancement of CHF at 50 and 100 kg/m 2 s under a 10 K subcooling condition. It means that the additional thermal margin could be acquired by just adding the GO nanoparticles to the flooding water without severe economic concerns. It is also found that this CHF enhancement is caused by coating the graphene oxide nanoparticles on the heated surface. However, the sessile drop tests on the coated heater surface show that the wettability of GO coated surface is not improved. The results of IR thermography show that one of the promising reasons is the change of thermal activity due to the coated GO nanoparticles on the heated surface
Energy Technology Data Exchange (ETDEWEB)
Zhang, Haibin, E-mail: hb-zhang@xjtu.edu.cn [School of Chemical Engineering and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Department of Chemical Engineering, Imperial College, London SW7 2BY (United Kingdom); Hewitt, G.F., E-mail: g.hewitt@imperial.ac.uk [Department of Chemical Engineering, Imperial College, London SW7 2BY (United Kingdom)
2016-08-15
Highlights: • A phenomenological model to predict the CHF for flows in annuli is described. • New correlations of droplet entrainment and deposition are used. • The present model has good predictive capability in predicting CHF in annuli. - Abstract: In this paper, we present a phenomenological model to predict the CHF (critical heat flux) for upward annular flow in heated vertical annuli. In present model, a new set of correlations of droplet deposition and entrainment in annuli was used which were verified by comparison with the data of Moeck (1970) for developing liquid films in adiabatic annuli. In the results presented here, these new correlations have been used to predict 2249 independent data on critical heat flux (CHF) obtained both regarding internal heating of the rod as well as simultaneous heating of the rod and the outer tube in six heated vertical annuli under various mass flow rate, pressure and inlet quality and where the conditions were such that (as is most common) the CHF condition occurred in the annular flow regime. The comparisons between the calculated and measured CHFs showed that the present model has good predictive capability in predicting CHF.
Reversal of OFI and CHF in Research Reactors Operating at 1 to 50 Bar. Version 1.0
Energy Technology Data Exchange (ETDEWEB)
Kalimullah, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Olson, A. P. [Argonne National Lab. (ANL), Argonne, IL (United States); Dionne, B. [Argonne National Lab. (ANL), Argonne, IL (United States); Feldman, E. E. [Argonne National Lab. (ANL), Argonne, IL (United States); Matos, J. E. [Argonne National Lab. (ANL), Argonne, IL (United States)
2014-02-28
The conditions at which the critical heat flux (CHF) and the heat flux at the onset of Ledinegg flow instability (OFI) are equal, are determined for a coolant channel with uniform heat flux as a function of five independent parameters: the channel exit pressure (P), heated length (Lh) , heated diameter (Dh), inlet temperature (Tin), and mass flux (G). A diagram is made by plotting the mass flux and heat flux at the OFI-CHF intersection (reversal from CHF > OFI to CHF < OFI as G increases) as a function of P (1 to 50 bar), for 36 combinations of the remaining three parameters (Lh , Dh , Tin): Lh = 0.28, 0.61, 1.18 m; Dh = 3, 4, 6, 8 mm; Tin = 30, 50, 70 °C. The use of the diagram to scope whether a research reactor is OFI-limited (below the curve) or CHF-limited based on the five parameters of its coolant channel is described. Justification for application of the diagram to research reactors with axially non-uniform heat flux is provided. Due to its limitations (uncertainties not included), the diagram cannot replace the detailed thermal-hydraulic analysis required for a reactor safety analysis. In order to make the OFI-CHF intersection diagram, two world-class CHF prediction methods (the Hall-Mudawar correlation and the extended Groeneveld 2006 table) are compared for 216 combinations of the five independent parameters. The two widely used OFI correlations (the Saha- Zuber and the Whittle-Forgan with η = 32.5) are also compared for the same combinations of the five parameters. The extended Groeneveld table and the Whittle-Forgan OFI correlation are selected for use in making the diagram. Using the above five design parameters, a research reactor can be represented by a point on the reversal diagram, and the diagram can be used to scope, without a thermal-hydraulic calculation, whether the OFI will occur before the CHF, or the CHF will occur before the OFI when the reactor power is increased keeping the five parameters fixed.
Directory of Open Access Journals (Sweden)
Bianca Beghé
Full Text Available Chronic obstructive pulmonary disease (COPD and chronic heart failure (CHF may coexist in elderly patients with a history of smoking. Low-grade systemic inflammation induced by smoking may represent the link between these 2 conditions. In this study, we investigated left ventricular dysfunction in patients primarily diagnosed with COPD, and nonreversible airflow limitation in patients primarily diagnosed with CHF. The levels of circulating high-sensitive C-reactive protein (Hs-CRP, pentraxin 3 (PTX3, interleukin-1β (IL-1 β, and soluble type II receptor of IL-1 (sIL-1RII were also measured as markers of systemic inflammation in these 2 cohorts. Patients aged ≥ 50 years and with ≥ 10 pack years of cigarette smoking who presented with a diagnosis of stable COPD (n=70 or stable CHF (n=124 were recruited. All patients underwent echocardiography, N-terminal pro-hormone of brain natriuretic peptide measurements, and post-bronchodilator spirometry. Plasma levels of Hs-CRP, PTX3, IL-1 β, and sIL-1RII were determined by using a sandwich enzyme-linked immuno-sorbent assay in all patients and in 24 healthy smokers (control subjects. Although we were unable to find a single COPD patient with left ventricular dysfunction, we found nonreversible airflow limitation in 34% of patients with CHF. On the other hand, COPD patients had higher plasma levels of Hs-CRP, IL1 β, and sIL-1RII compared with CHF patients and control subjects (p < 0.05. None of the inflammatory biomarkers was different between CHF patients and control subjects. In conclusion, although the COPD patients had no evidence of CHF, up to one third of patients with CHF had airflow limitation, suggesting that routine spirometry is warranted in patients with CHF, whereas echocardiography is not required in well characterized patients with COPD. Only smokers with COPD seem to have evidence of systemic inflammation.
International Nuclear Information System (INIS)
Le Corre, J.M.
2009-01-01
The current achievements and needs toward the investigation, understanding and mechanistic prediction of the Critical Heat Flux (CHF) event, under PWR and BWR core conditions, are addressed in this paper. It is shown that, even when using advanced 3-D CFD simulation tools, the current approach to CHF mechanistic modeling has serious limitations. This is mainly due to the lack of information regarding the relevant two-phase flow pattern(s) (in particular near the heated wall) and associated mechanisms (at the meso and micro-scale) leading to the CHF event. Areas of current experimental needs are identified in order to address these shortcomings. In addition, the use of 1-D and 3-D numerical tools to mechanistically predict the CHF is discussed. It is shown that 3-D two-phase CFD codes may not be superior to 1-D codes without proper consideration of relevant constitutive relations. (author)
Thermal electron attachment to CHF2CL in mixtures with CO2 and N2
International Nuclear Information System (INIS)
Szamrej, I.; Jowko, J.; Forys, M.
1996-01-01
Electron attachment to CHF 2 Cl in mixtures with nitrogen and carbon dioxide has been investigated using an electron swarm method. The attachment mechanism involving both two-body process and electron capture by van der Waals complexes ((CHF 2 Cl x N 2 ) and CHF 2 Cl) was found. The corresponding rate constants are equal to (1.1 ± 0.1) x 10- 13 cm 3 molec -1 s -1 , (2.0 ± 0.1) x 10 -33 cm 6 ) molec -2 s -1 and (1.1 ± 0.1) x 10- 50 cm 9 molec -3 ) s -1 , respectively. (Author)
The PDE4 inhibitor CHF-6001 and LAMAs inhibit bronchoconstriction-induced remodeling in lung slices.
Kistemaker, Loes E M; Oenema, Tjitske A; Baarsma, Hoeke A; Bos, I Sophie T; Schmidt, Martina; Facchinetti, Fabrizio; Civelli, Maurizio; Villetti, Gino; Gosens, Reinoud
2017-09-01
Combination therapy of PDE4 inhibitors and anticholinergics induces bronchoprotection in COPD. Mechanical forces that arise during bronchoconstriction may contribute to airway remodeling. Therefore, we investigated the impact of PDE4 inhibitors and anticholinergics on bronchoconstriction-induced remodeling. Because of the different mechanism of action of PDE4 inhibitors and anticholinergics, we hypothesized functional interactions of these two drug classes. Guinea pig precision-cut lung slices were preincubated with the PDE4 inhibitors CHF-6001 or roflumilast and/or the anticholinergics tiotropium or glycopyorrolate, followed by stimulation with methacholine (10 μM) or TGF-β 1 (2 ng/ml) for 48 h. The inhibitory effects on airway smooth muscle remodeling, airway contraction, and TGF-β release were investigated. Methacholine-induced protein expression of smooth muscle-myosin was fully inhibited by CHF-6001 (0.3-100 nM), whereas roflumilast (1 µM) had smaller effects. Tiotropium and glycopyrrolate fully inhibited methacholine-induced airway remodeling (0.1-30 nM). The combination of CHF-6001 and tiotropium or glycopyrrolate, in concentrations partially effective by themselves, fully inhibited methacholine-induced remodeling in combination. CHF-6001 did not affect airway closure and had limited effects on TGF-β 1 -induced remodeling, but rather, it inhibited methacholine-induced TGF-β release. The PDE4 inhibitor CHF-6001, and to a lesser extent roflumilast, and the LAMAs tiotropium and glycopyrrolate inhibit bronchoconstriction-induced remodeling. The combination of CHF-6001 and anticholinergics was more effective than the individual compounds. This cooperativity might be explained by the distinct mechanisms of action inhibiting TGF-β release and bronchoconstriction. Copyright © 2017 the American Physiological Society.
CHF-KFK-3: A critical heat flux correlation for triangular arrays of rods with tight lattices
International Nuclear Information System (INIS)
Dalle Donne, M.
1991-02-01
High converting PWR's (HCPWR or APWR) are based on fuel elements with rods placed in a tight lattice triangular array. The CHF correlation development previously at KfK for such geometry (CHF-KFK-2 correlation) has been tested against recently performed experiments. The comparison with the Siemens-KWU experiments with rod clusters with spacer grid and six integral spiral ribs supports has allowed to improve and extended the previous correlation. A new correlation, called CHF-KFK-3, which accounts for these improvements, is presented in the paper. (orig.) [de
International Nuclear Information System (INIS)
Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.
1993-01-01
The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of prediting CHF at these local conditions, makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries
Intelligent data analysis: the best approach for chronic heart failure (CHF) follow up management.
Mohammadzadeh, Niloofar; Safdari, Reza; Baraani, Alireza; Mohammadzadeh, Farshid
2014-08-01
Intelligent data analysis has ability to prepare and present complex relations between symptoms and diseases, medical and treatment consequences and definitely has significant role in improving follow-up management of chronic heart failure (CHF) patients, increasing speed and accuracy in diagnosis and treatments; reducing costs, designing and implementation of clinical guidelines. The aim of this article is to describe intelligent data analysis methods in order to improve patient monitoring in follow and treatment of chronic heart failure patients as the best approach for CHF follow up management. Minimum data set (MDS) requirements for monitoring and follow up of CHF patient designed in checklist with six main parts. All CHF patients that discharged in 2013 from Tehran heart center have been selected. The MDS for monitoring CHF patient status were collected during 5 months in three different times of follow up. Gathered data was imported in RAPIDMINER 5 software. Modeling was based on decision trees methods such as C4.5, CHAID, ID3 and k-Nearest Neighbors algorithm (K-NN) with k=1. Final analysis was based on voting method. Decision trees and K-NN evaluate according to Cross-Validation. Creating and using standard terminologies and databases consistent with these terminologies help to meet the challenges related to data collection from various places and data application in intelligent data analysis. It should be noted that intelligent analysis of health data and intelligent system can never replace cardiologists. It can only act as a helpful tool for the cardiologist's decisions making.
Experimental evidence for the blue-shifted hydrogen-bonded complexes of CHF3 with π-electron donors.
Gopi, R; Ramanathan, N; Sundararajan, K
2017-06-15
Blue-shifted hydrogen-bonded complexes of fluoroform (CHF 3 ) with benzene (C 6 H 6 ) and acetylene (C 2 H 2 ) have been investigated using matrix isolation infrared spectroscopy and ab initio computations. For CHF 3 -C 6 H 6 complex, calculations performed at the B3LYP and MP2 levels of theory using 6-311++G (d,p) and aug-cc-pVDZ basis sets discerned two minima corresponding to a 1:1 hydrogen-bonded complex. The global minimum correlated to a structure, where the interaction is between the hydrogen of CHF 3 and the π-electrons of C 6 H 6 and a weak local minimum was stabilized through H…F interaction. For the CHF 3 -C 2 H 2 complex, computation performed at MP2/aug-cc-pVDZ level of theory yielded two minima, corresponding to the cyclic C-H…π complex A (global) and a linear C-H…F (n-σ) complex B (local). Experimentally a blue-shift of 32.3cm -1 and 7.7cm -1 was observed in the ν 1 C-H stretching mode of CHF 3 sub-molecule in Ar matrix for the 1:1 C-H…π complexes of CHF 3 with C 6 H 6 and C 2 H 2 respectively. Natural bond orbital (NBO), Atoms-in-molecule (AIM) and energy decomposition (EDA) analyses were carried out to explain the blue-shifting and the nature of the interaction in these complexes. Copyright © 2017 Elsevier B.V. All rights reserved.
Directory of Open Access Journals (Sweden)
D. Bestion
2009-01-01
Full Text Available The NURESIM Project of the 6th European Framework Program initiated the development of a new-generation common European Standard Software Platform for nuclear reactor simulation. The thermal-hydraulic subproject aims at improving the understanding and the predictive capabilities of the simulation tools for key two-phase flow thermal-hydraulic processes such as the critical heat flux (CHF. As part of a multi-scale analysis of reactor thermal-hydraulics, a two-phase CFD tool is developed to allow zooming on local processes. Current industrial methods for CHF mainly use the sub-channel analysis and empirical CHF correlations based on large scale experiments having the real geometry of a reactor assembly. Two-phase CFD is used here for understanding some boiling flow processes, for helping new fuel assembly design, and for developing better CHF predictions in both PWR and BWR. This paper presents a review of experimental data which can be used for validation of the two-phase CFD application to CHF investigations. The phenomenology of DNB and Dry-Out are detailed identifying all basic flow processes which require a specific modeling in CFD tool. The resulting modeling program of work is given and the current state-of-the-art of the modeling within the NURESIM project is presented.
Energy Technology Data Exchange (ETDEWEB)
Marshall, T.D. [Rensselaer Polytechnic Institute, Troy, NY (United States); Watson, R.D.; McDonald, J.M. [Sandia National Lab., Albuquerque, NM (United States)] [and others
1995-09-01
In an off-normal event, water-cooled copper divertor plates in the International Thermonuclear Experimental Reactor (ITER) may either experience heat loads beyond their design basis, or the normal heat loads may be accompanied by low coolant pressure and velocity. The purpose of this experiment was to illustrate that during one-sided heating, as in ITER, a copper divertor plate with the proper side wall thickness, at low system pressure and velocity can absorb without failing an incident heat flux, q{sub i}, that significantly exceed the value, q{sub i}{sup CHF}, which is associated with local CHF at the wall of the coolant channel. The experiment was performed using a 30 kW electron beam test system for heating of a square cross-section divertor heat sink with a smooth circular channel of 7.63 mm diameter. The heated width, length, and wall thickness were 16, 40, and 3 mm, respectively. Stable surface temperatures were observed at incident heat fluxes greater than the local CHF point, presumably due to circumferential conduction around the thick tube walls when q{sub i}{sup CHF} was exceeded. The Post-CHF enhancement factor, {eta}, is defined as the ratio of the incident burnout heat flux, q{sub i}{sup BO}, to q{sub i}{sup CHF}. For this experiment with water at inlet conditions of 70{degrees}C, 1 m/s, and 1 MPa, q{sub i}{sup CHF} and q{sub i}{sup BO} were 600 and 1100 W/cm{sup 2}, respectively, which gave an {eta} of 1.8.
New models of droplet deposition and entrainment for prediction of CHF in cylindrical rod bundles
Energy Technology Data Exchange (ETDEWEB)
Zhang, Haibin, E-mail: hb-zhang@xjtu.edu.cn [School of Chemical Engineering and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Department of Chemical Engineering, Imperial College, London SW7 2BY (United Kingdom); Hewitt, G.F. [Department of Chemical Engineering, Imperial College, London SW7 2BY (United Kingdom)
2016-08-15
Highlights: • New models of droplet deposition and entrainment in rod bundles is developed. • A new phenomenological model to predict the CHF in rod bundles is described. • The present model is well able to predict CHF in rod bundles. - Abstract: In this paper, we present a new set of model of droplet deposition and entrainment in cylindrical rod bundles based on the previously proposed model for annuli (effectively a “one-rod” bundle) (2016a). These models make it possible to evaluate the differences of the rates of droplet deposition and entrainment for the respective rods and for the outer tube by taking into account the geometrical characteristics of the rod bundles. Using these models, a phenomenological model to predict the CHF (critical heat flux) for upward annular flow in vertical rod bundles is described. The performance of the model is tested against the experimental data of Becker et al. (1964) for CHF in 3-rod and 7-rod bundles. These data include tests in which only the rods were heated and data for simultaneous uniform and non-uniform heating of the rods and the outer tube. It was shown that the predicted CHFs by the present model agree well with the experimental data and with the experimental observation that dryout occurred first on the outer rods in 7-rod bundles. It is expected that the methodology used will be generally applicable in the prediction of CHF in rod bundles.
CRT-D Therapy in Patients with Decompensated NYHA Class-Four CHF
Directory of Open Access Journals (Sweden)
Faisal Zaeem
2012-01-01
Full Text Available Background. ACC-HRS Guidelines for Cardiac Resynchronization Therapy ICD implantation (CRT-D do not include patients with advanced nonambulatory NYHA class-four CHF due to an expectation of limited survival. There is little data available from these large multicenter randomized studies to support or refute this claim. Purpose. We evaluated the outcomes of patients with advanced nonambulatory NYHA class-four CHF who received CRT-D devices as an attempt to improve the clinical status and promote hospital discharge. Methods. Sixteen (of our six hundred and seventy CRT-D patients were classified as advanced nonambulatory NYHA Class four inotrope/vasodilator/diuretic-dependent patients. These patients were analyzed retrospectively for weaning success to oral medications, hospital discharge, hemodynamic stability, and survival over eighteen months. Results. Thirteen of sixteen patients were discharged to home within two weeks of implantation. The survival to hospital discharge, as well as at six, twelve, and eighteen months was positive (ninety-four percent, seventy-five percent, sixty-nine percent, sixty-nine percent, resp.. The groups showed significant improvements in systolic blood pressure, renal function, left ventricular ejection fraction, and CHF class. Conclusion. CRT-D in advanced nonambulatory NYHA four patients proved feasible and beneficial. These findings suggest that the strategy merits further study.
Energy Technology Data Exchange (ETDEWEB)
Hwang, Won Ki; Lee, Yun Seok; Lim, Dong Young; Song, Sub Lee; Lee, Jae Young; Lee, Kwon Yeong [Hanyang Global University, Pohang (Korea, Republic of); Hwang, Dong Soo [POSTECH, Pohang (Korea, Republic of)
2016-05-15
Critical heat flux (CHF) is enhancement of a boiling system will make more compact and effective cooling systems, for examples, nuclear reactors, and air conditioning units. For decades, researchers have been trying to develop more efficient working fluid for heat transfer. This is where nano-fluid could play a key role. There have been a lot of researches for CHF enhancements in nucleate boiling by using nano-fluid which are composed of metal such as copper, Al{sub 2}O{sub 3} and ceramic. And a critical factor of the enhancement is deposition of nano-particles on heating surface, although some results of recent studies are contrary. Also, previous nano-fluid are expensive and have a problem in mass production, so they are difficult to apply to practical industries. Therefore we chose a new material, cellulose nano fiber (CNF) as a solution. CNF can be applied to real situation because it has some advantages which are cost-effectiveness, easiness to get and to make it in nano scale. CHF performance of CNF fluid was different from that of distilled water. Compared to CHF of distilled water, CHF of the CNF fluid which had 0.001V%, 0.01V%, and 0.1V% volumetric concentrations were enhanced to 1%, 104%, and 13% respectively. Likewise other nano-fluid, deposition phenomena was observed in this CNF fluid boiling experiment.
International Nuclear Information System (INIS)
Hwang, Won Ki; Lee, Yun Seok; Lim, Dong Young; Song, Sub Lee; Lee, Jae Young; Lee, Kwon Yeong; Hwang, Dong Soo
2016-01-01
Critical heat flux (CHF) is enhancement of a boiling system will make more compact and effective cooling systems, for examples, nuclear reactors, and air conditioning units. For decades, researchers have been trying to develop more efficient working fluid for heat transfer. This is where nano-fluid could play a key role. There have been a lot of researches for CHF enhancements in nucleate boiling by using nano-fluid which are composed of metal such as copper, Al_2O_3 and ceramic. And a critical factor of the enhancement is deposition of nano-particles on heating surface, although some results of recent studies are contrary. Also, previous nano-fluid are expensive and have a problem in mass production, so they are difficult to apply to practical industries. Therefore we chose a new material, cellulose nano fiber (CNF) as a solution. CNF can be applied to real situation because it has some advantages which are cost-effectiveness, easiness to get and to make it in nano scale. CHF performance of CNF fluid was different from that of distilled water. Compared to CHF of distilled water, CHF of the CNF fluid which had 0.001V%, 0.01V%, and 0.1V% volumetric concentrations were enhanced to 1%, 104%, and 13% respectively. Likewise other nano-fluid, deposition phenomena was observed in this CNF fluid boiling experiment.
CHF Enhancement in Flow Boiling using Al2O3 Nano-Fluid and Al2O3 Nano-Particle Deposited Tube
International Nuclear Information System (INIS)
Kim, Tae Il; Chun, T. H.; Chang, S. H.
2010-01-01
Nano-fluids are considered to have strong ability to enhance CHF. Most CHF experiments using nano-fluids were conducted in pool boiling conditions. However there are very few CHF experiments with nano-fluids in flow boiling condition. In the present study, flow boiling CHF experiments using bare round tube with Al 2 O 3 nano-fluid and Al 2 O 3 nano-particle deposited tube with DI water were conducted under atmospheric pressure. CHFs were enhanced up to ∼ 80% with Al 2 O 3 nano-fluid and CHFs with Al 2 O 3 nano-particle deposited tube were also enhanced up to ∼ 80%. Inner surface of test section tube were observed by SEM and AFM after CHF experiments
Assessment of a non-uniform heat flux correction model to predicting CHF in PWR rod bundles
International Nuclear Information System (INIS)
Dae-Hyun, Hwang; Sung-Quun, Zee
2001-01-01
The full text follows. The prediction of CHF (critical heat flux) has been, in most cases, based on the empirical correlation. For PWR fuel assemblies the local parameter correlation requires the local thermal-hydraulic conditions usually calculated by a subchannel analysis code. The cross-sectional averaged fluid conditions of the subchannel, however, are not sufficient for determining CHF, especially for the cases of non-uniform axial heat flux distributions. Many investigators have studied the effect of the upstream heat flux on the CHF. In terms of the upstream memory effect, two different approaches have been considered as the limiting cases. The 'local conditions' hypothesis assumes that there is a unique relationship between the CHF and the local thermal-hydraulic conditions, and consequently there is no memory effect. In the 'overall power' hypothesis, on the other hand, it is assumed that the total power which can be fed into the tube with nonuniform heating will be the same as that for a uniformly heated tube of the same heated length with the same inlet conditions. Thus the CHF is totally influenced by the upstream heat flux distribution. In view of some experimental investigations such as the DeBortoli's test, it revealed that the two approaches are inadequate in general. It means that the local critical heat flux may be affected to some extent by the heat flux distribution upstream of the CHF location. Some correction-factor models have been suggested to take into account the upstream memory effect. Typically, Tong devised a correction factor on the basis of the heat balance of the superheated liquid layer that is spread underneath a highly viscous bubbly layer along the heated surface. His physical model suggested that the fluid enthalpy obtained from an energy balance of the superheated liquid layer is a representative quantity for the onset of DNB (departure nucleate boiling). A theoretically based correction factor model has been proposed by the
Glaser, Kirsten; Fehrholz, Markus; Henrich, Birgit; Claus, Heike; Papsdorf, Michael; Speer, Christian P
2017-02-01
Synthetic surfactants represent a promising alternative to animal-derived preparations in the treatment of neonatal respiratory distress syndrome. The synthetic surfactant CHF5633 has proven biophysical effectiveness and, moreover, demonstrated anti-inflammatory effects in LPS-stimulated monocytes. With ureaplasmas being relevant pathogens in preterm lung inflammation, the present study addressed immunomodulatory features on Ureaplasma-induced monocyte cytokine responses. Ureaplasma parvum-stimulated monocytes were exposed to CHF5633. TNF-α, IL-1β, IL-8, IL-10, TLR2 and TLR4 expression were analyzed using qPCR and flow cytometry. CHF5633 did not induce pro-inflammation, and did not aggravate Ureaplasma-induced pro-inflammatory cytokine responses. It suppressed U. parvum-induced intracellular TNF-α (p Ureaplasma-induced TNF-α mRNA (p Ureaplasma-modulated IL-8, IL-10, TLR2 and TLR4 were unaffected. CHF5633 does neither act pro-apoptotic nor pro-inflammatory in native and Ureaplasma-infected monocytes. Suppression of Ureaplasma-induced TNF-α and IL-1β underlines anti-inflammatory features of CHF5633.
Evaluation of mechanistic DNB models using HCLWR CHF data
International Nuclear Information System (INIS)
Iwamura, Takamichi; Watanabe, Hironori; Okubo, Tsutomu; Araya, Fumimasa; Murao, Yoshio.
1992-03-01
An onset of departure from nucleate boiling (DNB) in light water reactor (LWR) has been generally predicted with empirical correlations. Since these correlations have less physical bases and contain adjustable empirical constants determined by best fitting of test data, applicable geometries and flow conditions are limited within the original experiment ranges. In order to obtain more universal prediction method, several mechanistic DNB models based on physical approaches have been proposed in recent years. However, the predictive capabilities of mechanistic DNB models have not been verified successfully especially for advanced LWR design purposes. In this report, typical DNB mechanistic models are reviewed and compared with critical heat flux (CHF) data for high conversion light water reactor (HCLWR). The experiments were performed using triangular 7-rods array with non-uniform axial heat flux distribution. Test pressure was 16 MPa, mass velocities ranged from 800 t0 3100 kg/s·m 2 and exit qualities from -0.07 to 0.19. The evaluated models are: 1) Wisman-Pei, 2) Chang-Lee, 3) Lee-Mudawwar, 4) Lin-Lee-Pei, and 5) Katto. The first two models are based on near-wall bubble crowding model and the other three models on sublayer dryout model. The comparison with experimental data indicated that the Weisman-Pei model agreed relatively well with the CHF data. Effects of empirical constants in each model on CHF calculation were clarified by sensitivity studies. It was also found that the magnitudes of physical quantities obtained in the course of calculation were significantly different for each model. Therefore, microscopic observation of the onset of DNB on heated surface is essential to clarify the DNB mechanism and establish a general DNB mechanistic model based on physical phenomenon. (author)
International Nuclear Information System (INIS)
Yang, R.C.; Shi, D.Q.; Lu, Z.Q.; Zheng, R.C.; Wang, Y.
1996-01-01
Experimental study has been performed to investigate flow instability and critical heat flux (CHF) in a natural circulation system with subcooled boiling. In the experiments three kinds of heated sections were used. Freon-12 was used as the working medium. The experiments show which one of the two phenomena, flow instability and CHF condition, may first occur in the system depends on not only the heat input power to the heated section and the parameters of the working medium, but also the construction of the heated section. The occurrence of the flow instability mainly depends on the total heat input power to the heated section and the CHF condition is mainly caused by the local heat flux of the heated section. In the experiments two kinds of flow instability, flow instability with high frequency and flow instability with low frequency, were found. But they all belong to density wave instability. The influence of the parameters of the working medium on the onset of the flow instability and CHF condition in the system were investigated. The stability boundaries were determined through the experiments. By means of dimensional analysis of integral equations, a common correlation describing the threshold condition of onset of the flow instability was obtained
Atmospheric Lifetime of CHF2Br, a Proposed Substitute for Halons.
Talukdar, R; Mellouki, A; Gierczak, T; Burkholder, J B; McKeen, S A; Ravishankara, A R
1991-05-03
The rate coefficients, k(1), for the reaction of OH with CHF(2)Br have been measured using pulsed photolysis and discharge flow techniques at temperatures (T) between 233 and 432 K to be k(1), = (7.4 +/- 1.6) x 10(-13) exp[-(1300 +/- 100)/T] cubic centimeters per molecule per second. The ultraviolet absorption cross sections, sigma, of this molecule between 190 and 280 nanometers were measured at 296 K. The k(1), and sigma values were used in a one-dimensional model to obtain an atmospheric lifetime of approximately 7 years for CHF(2)Br. This lifetime is shorter by approximately factors of 10 and 2 than those for CF(3)Br and CF(2)ClBr, respectively. The ozone depletion potentials of the three compounds will reflect these lifetimes.
CHF: circulatory homeostasis gone awry.
Weber, Karl T; Burlew, Brad S; Davis, Richard C; Newman, Kevin P; D'Cruz, Ivan A; Hawkins, Ralph G; Wall, Barry M; Parker, Robert B
2002-01-01
The role of the renin-angiotensin-aldosterone system (RAAS) is integral to salt and water retention, particularly by the kidneys. Over time, positive sodium balance leads first to intra- and then to extravascular volume expansion, with subsequent symptomatic heart failure. This report examines the role of the RAAS in regulating a less well recognized component essential to circulatory homeostasis--central blood volume. The regulation of central blood volume draws on integrative cardiorenal physiology and a key role played by the RAAS in its regulation. In presenting insights into the role of the RAAS in regulating central blood volume, this review also addresses other sodium-retaining states with a predisposition to edema formation, such as cirrhosis and nephrosis. (c)2002 CHF, Inc
International Nuclear Information System (INIS)
Lee, M.
2000-01-01
The critical heat flux (CHF) approach using CHF look-up tables has become a widely accepted CHF prediction technique. In these approaches, the CHF tables are developed based mostly on the data bank for flow in circular tubes. A set of correction factors was proposed by Groeneveld et al. [Groeneveld, D.C., Cheng, S.C., Doan, T. (1986)] to extend the application of the CHF table to other flow situations including flow in rod bundles. The proposed correction factors are based on a limited amount of data not specified in the original paper. The CHF approach of Groeneveld and co-workers is extensively used in the thermal hydraulic analysis of nuclear reactors. In 1996, Groeneveld et al. proposed a new CHF table to predict CHF in circular tubes [Groeneveld, D.C., et al., 1996. The 1995 look-up table for Critical Heat Flux. Nucl. Eng. Des. 163(1), 23]. In the present study, a set of correction factors is developed to extend the applicability of the new CHF table to flow in rod bundles of square array. The correction factors are developed by minimizing the statistical parameters of the ratio of the measured and predicted bundle CHF data from the Heat Transfer Research Facility. The proposed correction factors include: the hydraulic diameter factor (K hy ), the bundle factor (K bf ), the heated length factor (K hl ), the grid spacer factor (K sp ), the axial flux distribution factors (K nu ), the cold wall factor (K cw ) and the radial power distribution factor (K rp ). The value of constants in these correction factors is different when the heat balance method (HBM) and direct substitution method (DSM) are adopted to predict the experimental results of HTRF. With the 1995 Groeneveld CHF Table and the proposed correction factors, the average relative error is 0.1 and 0.0% for HBM and DSM, respectively, and the root mean square (RMS) error is 31.7% in DSM and 17.7% in HBM for 9852 square array data points of HTRF. (orig.)
Benteşen Yakut, Yurdagül; Sünter, Sedat; Özdemir, Mehmet
2017-01-01
U ovom je radu predstavljena metoda upravljanja pogonom dva sinhrona motora s paralelno povezanim trajnim magnetom, napajana jednim pretvaračem. Ovdje primijenjeni matrični konverter omogućuje ac-ac konverziju u jednom stupnju. Model matričnog konvertera i d-q model dvostrukih PMSMs izvode se u Matlab/Simulink-u. U industrijskim primjenama s dvostrukim motorima napajanim iz jedinstvenog pretvarača, smanjuje se volumen i težina pogonskog sustava, reduciraju se energetsko elektronički prekidači...
DEFF Research Database (Denmark)
Carrington, Melinda J; Stewart, Simon; de Courten, Barbora
2010-01-01
AIMS: The primary objective of the Nurse-led Intervention for Less Chronic Heart Failure (NIL-CHF) Study is to develop a programme of care that cost-effectively prevents the development of chronic heart failure (CHF). Methods NIL-CHF is a randomized controlled trial of a hybrid, home- and clinic-...
International Nuclear Information System (INIS)
Juarsa, Mulya; Putra, Nandy; Septiadi, Wayan Nata; Antariksawan, Anhar Riza
2014-01-01
Highlights: • Quenching in narrow rectangular channel with gap sizes variation was investigated. • The mechanism of counter-current flow depends on gap sizes variation. • The results confirmed the existence of CCFL in narrow rectangular channels. • CHF and mass flux gradient in the quenching was about 0.22 times than steady state. • Modification of CHF and mass flow rate dimensionless correlation was established. - Abstract: The quenching process has become an important thermal management study to intensify the safety margin for the integrity of the reactor vessel under the core meltdown condition. The boiling heat transfer mechanism in the channel is one aspect that needs further examination. The present study aimed to investigate the effect of the differences in channel gap size to counter-current flow limitation (CCFL) and critical heat flux (CHF) during transient cooling in atmospheric pressure and quenching using two vertical plates with 1 mm, 2 mm, and 3 mm gap sizes and heated length of 1100 mm. The initial temperature of the plate was set at 600 °C. Cooling water mass flow rate and sib-cooled temperature were set at about 0.089 kg/s and 90 °C, respectively. Calculations were performed to obtain the CHF value through the boiling curve using transient temperature data. Non-dimensional correlations from other research study was used in this research. The influence of gap sizes on CCFL and CHF resulted in an increased value of CHF relative to gap size; additionally, the CHF for gap sizes of 2 mm and 3 mm increased about 34.4% and 140.5%, respectively, compared to the CHF for the 1 mm gap size. In this research, a curve map of the relationship between non-dimensional CHF and non-dimensional mass flux of water flowing downward shows that the correlation of this experimental study has a gradient number of about 0.22 similar to Mishima and Nishihara correlation. The results confirmed the existence of CCFL in the vertical narrow rectangular channels due
International Nuclear Information System (INIS)
Kiteley, J.C.; Carver, M.B.; Zhou, Q.N.
1993-01-01
The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of CANDU PHWR fuel channels, and to provide a detailed prediction of critical heat flux distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting critical heat flux (CHF) at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental data base. In particular, ASSERT is the only tool available to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. This paper discusses the numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology. The evolutionary validation plan is discussed, and early validation exercises are summarized. The paper concentrates, however, on more recent validation exercises in standard and non-standard geometries. 28 refs., 12 figs
An assessment of prediction methods of CHF in tubes with a large experimental data bank
International Nuclear Information System (INIS)
Leung, L.K.H.; Groeneveld, D.C.
1993-01-01
An assessment of prediction methods of CHF in tubes has been carried out using an expanded CHF data bank at Chalk River Laboratories (CRL). It includes eight different CHF look-up tables (two AECL versions and six USSR (or Russian) versions) and three empirical correlations. These prediction methods were developed from relatively large data bases and therefore have a wide range of application. Some limitations, however, were imposed in this study, to avoid any invalid predictions due to extrapolation of these methods. Therefore, these comparisons are limited to the specific data base that is tailored to suit the range of an individual method. This has resulted in a different number of data used in each case. The comparison of predictions against the experimental data is based on the constant inlet-condition approach (i.e., the pressure, mass flux, inlet fluid temperature and tube geometry are the primary parameters). Overall, the AECL tables have the widest range of application. They are assessed with 21 771 data points and the root-mean-square error is only 8.3%. About 60% of these data were used in the development of the AECL tables. The best version of the USSR/Russian CHF table is valid for 13 300 data points with a root-mean-square error of 8.8%. The USSR/Russian table that has the widest range of application covers a total of 18 800 data points, but the error increases to 9.3%. The range of application for empirical correlations, however, are generally much narrower than those covered by the CHF tables. The number of data used to assess these correlations is therefore further limited. Among the tested correlations, the Becker and Persson correlation covers the least amount of data (only 7 499 data points), but has the best accuracy (with a root-mean-square error of 9.71%). 33 refs., 2 figs., 3 tabs
A Preliminary Experimental Study on Flow Boiling CHF Characteristics of Ballooned Channel
International Nuclear Information System (INIS)
Kim, Yong Jin; Song, Sub Lee; Chang, Soon Heung; Moon, Sang Ki
2013-01-01
The purpose of this research is to measure heat transfer characteristics experimentally and to develop correlation based on experimental data. Experiments are in progress. The result of preliminary experimental test of ballooned channel was reported. The trends of CHF value for deformed channel is not usual as normal smooth tube. The spot of CHF was moved by changing different experimental cases. The transition of flow pattern at neck of deformation is considered as main factor of changing CHF trends. More cases are under operation and analysis based on flow dynamics are developing. Cladding is one of the most important parts in nuclear power plant because it is second barrier of radiation leakage from nuclear fuel. Originally, cladding keeps its integrity in 1200 .deg. C and 150bar, which is normal operation state of nuclear power plant. However, integrity of cladding can be deformed by more severe conditions caused by accident. In case of LOCA, high temperature, oxidation and thermal shock induced by safety injection can deform cladding. Main problem of deformed cladding is blockage of cooled to prevent core melt accident. Change of flow path by blockage affects flow of safety coolant, heat transfer coefficient and critical heat flux of rod bundles. Until now, there are insufficient heat transfer data for deformed flow path compared to normal flow path. In order to enhance safety of nuclear power plant after accident, it should be clarified that how deformed cladding affects heat transfer
Kinetics and mechanisms of reactions of CF, CHF, and CF2 radicals
International Nuclear Information System (INIS)
Hsu, D.S.Y.; Umstead, M.E.; Lin, M.C.
1978-01-01
This chapter reviews briefly methods for the production of CF, CHF and CF 2 , and inmore detail, the reactions of these interesting and important radicals. Although a considerable, but not extensive, amount of work has been done on the reactions of CF 2 , little of the chemistry of CF and CHF is known. This chapter also includes the preliminary results of some experiments carried out in this Laboratory on the dynamics of some of the reactions involving these radicals. These results were largely arrived at through investigations of the degree of vibrational excitation of the HF and CO reaction products, determined by HF and CO laser emission and CO laser resonance absorption measurements. The coverage of this review is restricted to the gas phase chemistry of these radicals, and does not include their addition reactions to olefins
DEFF Research Database (Denmark)
Nielsen, O.J.; Ellermann, T.; Bartkiewicz, E.
1992-01-01
The ultraviolet-absorption spectrum and the self-reaction of CHF2O2 radicals have been studied in the gas phase at 298 K using the pulse radiolysis technique and long-pathlength Fourier transform infrared spectroscopy. Absorption cross sections were quantified over the wavelength range 220-280 nm....... The measured cross section near the absorption maximum was sigma(CHF2O2)(240 nm) = (2.66 +/- 0.46) x 10(-18) cm2 molecule-1. The absorption cross section data were used to derive the observed self-reaction rate constant for the reaction CHF2O2 + CHF2O2 --> products, defined as d[R]/dt = 2k(1obs)[CHF2O2]2, k(1......obs) = (5.0 +/- 0.7) x 10(-12) cm3 molecule-1 s-1 (+/- 2-sigma). The only carbon-containing product observed by FTIR spectroscopy was FC(O)F. These results are discussed with respect to previous studies of peroxy radicals....
Using text mining techniques to extract phenotypic information from the PhenoCHF corpus.
Alnazzawi, Noha; Thompson, Paul; Batista-Navarro, Riza; Ananiadou, Sophia
2015-01-01
Phenotypic information locked away in unstructured narrative text presents significant barriers to information accessibility, both for clinical practitioners and for computerised applications used for clinical research purposes. Text mining (TM) techniques have previously been applied successfully to extract different types of information from text in the biomedical domain. They have the potential to be extended to allow the extraction of information relating to phenotypes from free text. To stimulate the development of TM systems that are able to extract phenotypic information from text, we have created a new corpus (PhenoCHF) that is annotated by domain experts with several types of phenotypic information relating to congestive heart failure. To ensure that systems developed using the corpus are robust to multiple text types, it integrates text from heterogeneous sources, i.e., electronic health records (EHRs) and scientific articles from the literature. We have developed several different phenotype extraction methods to demonstrate the utility of the corpus, and tested these methods on a further corpus, i.e., ShARe/CLEF 2013. Evaluation of our automated methods showed that PhenoCHF can facilitate the training of reliable phenotype extraction systems, which are robust to variations in text type. These results have been reinforced by evaluating our trained systems on the ShARe/CLEF corpus, which contains clinical records of various types. Like other studies within the biomedical domain, we found that solutions based on conditional random fields produced the best results, when coupled with a rich feature set. PhenoCHF is the first annotated corpus aimed at encoding detailed phenotypic information. The unique heterogeneous composition of the corpus has been shown to be advantageous in the training of systems that can accurately extract phenotypic information from a range of different text types. Although the scope of our annotation is currently limited to a single
International Nuclear Information System (INIS)
Carneiro, J. Walkimar de M.; Dias, Jacques F.; Seidl, Peter R.; Tostes, J. Glauco R.
2002-01-01
Our previous DFT/GIAO calculations on different types of alcohols reveal that the rotation of the hydroxyl group can affect the chemical shift of carbons and hydrogens close to the substituent in different ways. Besides the steric and electrostatic effects that have been widely studied, hyperconjugation with the lone pairs on oxygen of the hydroxyl group leads to changes in bond lengths and angles as well as to different charge distributions. As all three of these factors also affect chemical shifts, we undertook a systematic investigation of their relative contributions to the chemical shifts of ethanol, a molecule in which there is minimum interference among these factors. Calculations by the B3LYP method at the 6-31G(d) level for ethanol conformers corresponding to a rotation around the carbon-oxygen bond at 30 dec increments are used to show how relative contributions vary with the dihedral angle formed between the carbon-carbon and oxygen-hydrogen bonds (C-C-O-H). Largest contributions to carbon chemical shifts can be attributed to changes in bond lengths while for hydrogen chemical shifts also contribute significantly differences in charge distribution. (author)
CHF prediction in rod bundles using round tube data
Energy Technology Data Exchange (ETDEWEB)
Souza, Wallen F.; Veloso, Maria A.F.; Pereira, Cláubia; Costa, Antonella L., E-mail: wallenfds@yahoo.com.br, E-mail: mdora@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear
2017-07-01
The present work concerns the use of 1995 CHF table for uniformly heated round tubes, developed jointly by Canadian and Russian researchers, for the prediction of critical heat fluxes in rod bundles geometries. Comparisons between measured and calculated critical heat fluxes indicate that this table could be applied to rod bundles provided that a suitable correction factor is employed. The tolerance limits associated with the departure from nucleate boiling ratio (DNBR) are evaluated by using statistical analysis. (author)
Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research
International Nuclear Information System (INIS)
Iguchi, Tadashi; Itoh, Hideo; Kiuchi, Toshio; Watanabe, Hironori; Kimura, Mamoru; Anoda, Yoshinari
2001-03-01
JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to discuss the effect of axial position on thermal-hydraulics, while previous works usually discuss the thermal-hydraulics at the position where the first heat-up occurs. This data report describes test procedure, test condition and major experimental data of post-CHF tests. (author)
International Nuclear Information System (INIS)
Hall, D.D.; Mudawar, I.
1997-01-01
A simple methodology for assessing the predictive ability of critical heat flux (CHF) correlations applicable to subcooled flow boiling in a uniformly heated vertical tube is developed. Popular correlations published in handbooks and review articles as well as the most recent correlations are analyzed with the PU-BTPFL CHF database, which contains 29,718 CHF data points. This database is the largest collection of CHF data (vertical upflow of water in a uniformly heated round tube) ever cited in the world literature. The parametric ranges of the CHF database are diameters from 0.3 to 45 mm, length-to-diameter ratios from 2 to 2484, mass velocities from 0.01 x 10 3 to 138 x 10 3 kg/m 2 ·s, pressures from 1 to 223 bars, inlet subcoolings from 0 to 347 C, inlet qualities from -2.63 to 0.00, outlet subcoolings from 0 to 305 C, outlet qualities from -2.13 to 1.00, and CHFs from 0.05 x 10 6 to 276 x 10 6 W/m 2 . The database contains 4,357 data points having a subcooled outlet condition at CHF. A correlation published elsewhere is the most accurate in both low- and high-mass velocity regions, having been developed with a larger database than most correlations. In general, CHF correlations developed from data covering a limited range of flow conditions cannot be extended to other flow conditions without much uncertainty
Directory of Open Access Journals (Sweden)
Mayron F. Oliveira
2015-01-01
Full Text Available Impairment in oxygen (O2 delivery to the central nervous system (brain and skeletal locomotor muscle during exercise has been associated with central and peripheral neuromuscular fatigue in healthy humans. From a clinical perspective, impaired tissue O2 transport is a key pathophysiological mechanism shared by cardiopulmonary diseases, such as chronic obstructive pulmonary disease (COPD and chronic heart failure (CHF. In addition to arterial hypoxemic conditions in COPD, there is growing evidence that cerebral and muscle blood flow and oxygenation can be reduced during exercise in both isolated COPD and CHF. Compromised cardiac output due to impaired cardiopulmonary function/interactions and blood flow redistribution to the overloaded respiratory muscles (i.e., ↑work of breathing may underpin these abnormalities. Unfortunately, COPD and CHF coexist in almost a third of elderly patients making these mechanisms potentially more relevant to exercise intolerance. In this context, it remains unknown whether decreased O2 delivery accentuates neuromuscular manifestations of central and peripheral fatigue in coexistent COPD-CHF. If this holds true, it is conceivable that delivering a low-density gas mixture (heliox through non-invasive positive pressure ventilation could ameliorate cardiopulmonary function/interactions and reduce the work of breathing during exercise in these patients. The major consequence would be increased O2 delivery to the brain and active muscles with potential benefits to exercise capacity (i.e., ↓central and peripheral neuromuscular fatigue, respectively. We therefore hypothesize that patients with coexistent COPD-CHF stop exercising prematurely due to impaired central motor drive and muscle contractility as the cardiorespiratory system fails to deliver sufficient O2 to simultaneously attend the metabolic demands of the brain and the active limb muscles.
Effect of the Aligned Flow Obstacles on Downward-Facing CHF in an Inclined Rectangular Channel
Energy Technology Data Exchange (ETDEWEB)
Jeong, Ui ju; Son, Hong Hyun; Seo, Gwang Hyeok; Jeun, Gyoo Dong; Kim, Sung Joong [Hanyang, Seoul (Korea, Republic of)
2016-05-15
The cooling channel consists of the inclined (10 .deg. ) portion of the downward facing heating channel and vertical portion of the heating channel. Features unique to flow boiling with the downward-facing heater surface in the inclined cooling channel where the studs are installed have drawn a considerable attention. That's because prior studies on boiling crisis indicate the orientation of the heated wall can exert substantial influence on CHF. Especially, the concentration of the vapor near the downward facing heater surface makes this region susceptible to premature boiling crisis when compared to vertical or upward-facing heated wall. Also, the installed studs could cause a partial flow blockage, and distort the flow streamline. Due to the distortion, stagnation points may occur in the cooling channel, promoting the concentration of the vapor near the heated wall. Then, the locally degraded heat transfer around the points may result in the formation of vapor pocket. The primary objective of this study is to make available experimental data on the CHF values varying the shape of studs and to improve understanding of the mechanism of flow boiling crisis associated with the aligned flow obstructions by means of visual experimental study. This study presents experimental data for subcooled flow boiling of water at atmospheric pressure and low mass flux conditions. The major outcomes from this investigation can be summarized as follows: (1) The CHF value from bare test section is -320kW/m{sup 2} , significantly lower than the values from the existing correlations even considering the uncertainty in the experiments. (2) The CHF value is remarkably decreased as columnar structures are installed in the channel. It is confirmed that formation and extinction of local dryout occurs repeatedly just behind the first stud at heat flux of -160 kW/m{sup 2}.
DEFF Research Database (Denmark)
Nilsson, Elna Johanna Kristina; Nielsen, Ole John; Johnson, Matthew Stanley
2009-01-01
Long path length FTIR-smog chamber techniques were used to measure k(OH + cis-CF3CH@CHF) = (1.20 ± 0.14) 1012 and k(O3 + cis-CF3CH@CHF) = (1.65 ± 0.16) 1021 cm3 molecule 1 s1 in 700 Torr of N2/O2 diluent at 296 K. The OH initiated oxidation of cis-CF3CH@CHF gives CF3CHO and HCOF in molar yields w...
Mechanistic modeling of CHF in forced-convection subcooled boiling
International Nuclear Information System (INIS)
Podowski, M.Z.; Alajbegovic, A.; Kurul, N.; Drew, D.A.; Lahey, R.T. Jr.
1997-05-01
Because of the complexity of phenomena governing boiling heat transfer, the approach to solve practical problems has traditionally been based on experimental correlations rather than mechanistic models. The recent progress in computational fluid dynamics (CFD), combined with improved experimental techniques in two-phase flow and heat transfer, makes the use of rigorous physically-based models a realistic alternative to the current simplistic phenomenological approach. The objective of this paper is to present a new CFD model for critical heat flux (CHF) in low quality (in particular, in subcooled boiling) forced-convection flows in heated channels
International Nuclear Information System (INIS)
Banner, D.; Crecy, F. de.
1993-07-01
Comparison of CHF predictors has been performed by using the same Critical Heat Flux (CHF) databases but by deriving local thermal-hydraulic conditions from different codes (THYC-V3 and FLICA-3M). Predictions have been obtained by the pseudo-cubic Spline method (PCSM). It is shown that the two codes yield similar results provided that equivalent turbulent mixing coefficients are chosen. (author), 6 figs., 5 refs
Assessment of correlations and models for prediction of CHF in subcooled flow boiling
International Nuclear Information System (INIS)
Celata, G.P.; Mariani, A.; Cumo, M.
1992-01-01
This paper provides an analysis of available correlations and models for the prediction of Critical Heat Flux (CHF) in subcooled flow boiling in the ranges of interest of fusion reactor thermal-hydraulic conditions, i.e., high inlet liquid subcooling and velocity and small channel diameter and length. The aim of the study was to establish the limits of validity of present predictive tools (most of them were proposed with reference to LWR thermal-hydraulic studies) in the above conditions. The reference data-set represents most of available data covering wide ranges of operating conditions in the framework of present interest (0.1 s ub, in < 230 K). Among the tens of predictive tools available in literature, four correlations (Levy, Westinghouse, modified-Tong and Tong-75) and three models (Weisman and Ileslamlou Lee and Mudawar and Katto) were selected. The modified-Tong correlation and the Katto model seem to be reliable predictive tools for the calculation of the CHF in subcooled flow boiling
Munasinghe, Pradeep Chaminda; Khanal, Samir Kumar
2012-10-01
In this study, the volumetric mass transfer coefficients (Ka) for CO were examined in a composite hollow fiber (CHF) membrane bioreactor. The mass transfer experiments were conducted at various inlet gas pressures (from 5 to 30 psig (34.5-206.8 kPa(g))) and recirculation flow rates (300, 600, 900, 1200 and 1500 mL/min) through CHF module. The highest Ka value of 946.6 1/h was observed at a recirculation rate of 1500 mL/min and at an inlet gas pressure of 30 psig(206.8 kPa(g)). The findings of this study confirm that the use of CHF membranes is effective and improves the efficiency CO mass transfer into the aqueous phase. Copyright © 2012 Elsevier Ltd. All rights reserved.
Impact of bundle deformation on CHF: ASSERT-PV assessment of extended burnup Bruce B bundle G85159W
International Nuclear Information System (INIS)
Rao, Y.F.; Manzer, A.M.
2005-01-01
This paper presents a subchannel thermalhydraulic analysis of the effect on critical heat flux (CHF) of bundle deformation such as element bow and diametral creep. The bundle geometry is based on the post-irradiation examination (PIE) data of a single bundle from the Bruce B Nuclear Generating Station, Bruce B bundle G85159W, which was irradiated for more than two years in the core during reactor commissioning. The subchannel code ASSERT-PV IST is used to assess changes in CHF and dryout power due to bundle deformation, compared to the reference, undeformed bundle. (author)
Directory of Open Access Journals (Sweden)
Marzia Rigolli
2011-01-01
Full Text Available Background. Neurohormonal systems play an important role in chronic heart failure (CHF. Due to interindividual heterogeneity in the benefits of therapy, it may be hypothesized that polymorphisms of neurohormonal systems may affect left ventricular (LV remodelling and systolic function. We aimed to assess whether genetic background of maximally treated CHF patients predicts variations in LV systolic function and volumes. Methods and Results. We prospectively studied 131 CHF outpatients on optimal treatment for at least six months. Echocardiographic evaluations were performed at baseline and after 12 months. Genotype analysis for ACE I/D, β1adrenergic receptor (AR Arg389Gly, β2AR Arg16Gly, and β2AR Gln27Glu polymorphisms was performed. No differences in baseline characteristics were detected among subgroups. ACE II was a significant predictor of improvement of LV end-diastolic and end-systolic volume (=.003 and =.002, respectively but not of LV ejection fraction (LVEF; β1AR389 GlyGly was related to improvement of LVEF (=.02 and LV end-systolic volume (=.01. The predictive value of polymorphisms remained after adjustment for other clinically significant predictors (<.05 for all. Conclusions. ACE I/D and β1AR Arg389Gly polymorphisms are independent predictors of reverse remodeling and systolic function recovery in CHF patients under optimal treatment.
International Nuclear Information System (INIS)
Mudawar, I.; Galloway, J.E.; Gersey, C.O.
1995-01-01
Pool boiling and flow boiling were examined for near-saturated bulk conditions in order to determine the critical heat flux (CHF) trigger mechanism for each. Photographic studies of the wall region revealed features common to both situations. At fluxes below CHF, the vapor coalesces into a wavy layer which permits wetting only in wetting fronts, the portions of the liquid-vapor interface which contact the wall as a result of the interfacial waviness. Close examination of the interfacial features revealed the waves are generated from the lower edge of the heater in pool boiling and the heater's upstream region in flow boiling. Wavelengths follow predictions based upon the Kelvin-Helmholtz instability criterion. Critical heat flux in both cases occurs when the pressure force exerted upon the interface due to interfacial curvature, which tends to preserve interfacial contact with the wall prior to CHF, is overcome by the momentum of vapor at the site of the first wetting front, causing the interface to lift away from the wall. It is shown this interfacial lift-off criterion facilitates accurate theoretical modeling of CHF in pool boiling and in flow boiling in both straight and curved channels
Energy Technology Data Exchange (ETDEWEB)
Mudawar, I.; Galloway, J.E.; Gersey, C.O. [Purdue Univ., West Lafayette, IN (United States)] [and others
1995-12-31
Pool boiling and flow boiling were examined for near-saturated bulk conditions in order to determine the critical heat flux (CHF) trigger mechanism for each. Photographic studies of the wall region revealed features common to both situations. At fluxes below CHF, the vapor coalesces into a wavy layer which permits wetting only in wetting fronts, the portions of the liquid-vapor interface which contact the wall as a result of the interfacial waviness. Close examination of the interfacial features revealed the waves are generated from the lower edge of the heater in pool boiling and the heater`s upstream region in flow boiling. Wavelengths follow predictions based upon the Kelvin-Helmholtz instability criterion. Critical heat flux in both cases occurs when the pressure force exerted upon the interface due to interfacial curvature, which tends to preserve interfacial contact with the wall prior to CHF, is overcome by the momentum of vapor at the site of the first wetting front, causing the interface to lift away from the wall. It is shown this interfacial lift-off criterion facilitates accurate theoretical modeling of CHF in pool boiling and in flow boiling in both straight and curved channels.
An improved liquid film model to predict the CHF based on the influence of churn flow
International Nuclear Information System (INIS)
Wang, Ke; Bai, Bofeng; Ma, Weimin
2014-01-01
The critical heat flux (CHF) for boiling crisis is one of the most important parameters in thermal management and safe operation of many engineering systems. Traditionally, the liquid film flow model for “dryout” mechanism shows a good prediction in heated annular two-phase flow. However, a general assumption that the initial entrained fraction at the onset of annular flow shows a lack of reasonable physical interpretation. Since the droplets have great momentum and the length of churn flow is short, the droplets in churn flow show an inevitable effect on the downstream annular flow. To address this, we considered the effect of churn flow and developed the original liquid film flow model in vertical upward flow by suggesting that calculation starts from the onset of churn flow rather than annular flow. The results indicated satisfactory predictions with the experimental data and the developed model provided a better understanding about the effect of flow pattern on the CHF prediction. - Highlights: •The general assumption of initial entrained fraction is unreasonable. •The droplets in churn flow show an inevitable effect on downstream annular flow. •The original liquid film flow model for prediction of CHF was developed. •The integration process was modified to start from the onset of churn flow
Directory of Open Access Journals (Sweden)
Ngo, AT.
2016-01-01
Full Text Available Embedded in a package of climate change adaptation, researchers and farmers tested the melon hybrid variety, Kim Hoang Hau (KHH, for yield and disease resistance during the spring-summer season from March to June 2015 in Giao Thuy district, Nam Dinh province. The results were analysed and subsequently discussed with local farmers in focused groups. Analysis showed that the KHH was suitable to local soil conditions. The farmers preferred this new variety over the local melon, because not only did KHH give higher yield and pest resistance, it also showed less vulnerability to climatic stressors. Farmers decided to grow KHH based on the prevailing good market price at that time. However, farmers only shifted away from the old melon when they could anticipate the possibility of selling the new product. Those who did not continue with the KHH had difficulty in actively accessing the market for this new product. This study suggests that the market information does not solely drive the process of the adaptation itself, but it also provides relevant stimuli to farmers enabling them to successfully shift to new crop varieties. This study also implies that such process-based understanding is crucial in formulating strategies that increase the farmer's capacity to adapt to climate change.
Energy Technology Data Exchange (ETDEWEB)
Jiao, Bo; Yang, Dongyu [Department of Mechanical Engineering, Rongcheng Campus, Harbin University of Science and Technology, Rongcheng 264300, Shandong (China); Gan, Zhihua, E-mail: gan_zhihua@zju.edu.cn [Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou (China); Key Laboratory of Refrigeration and Cryogenic Technology of Zhejiang Province, Hangzhou (China); National Quality Inspection Center of Refrigeration Equipment (Henan), Minquan (China)
2017-06-15
Highlights: • A parallel look-up table for the entrainment fraction at annular point was developed. • A correlation was given based on the selected database from 2006 CHF look-up table. • Its reliability on the other conditions in the look-up table was discussed. - Abstract: The critical heat flux (CHF) of gas-liquid flow plays an important role in the safety of industrial equipment. At present, the liquid film dryout model is widely used for predicting CHF in gas-liquid annular flow. Most parameters in this model can be determined by some empirical correlations which are valid under different conditions. However, up to now, the entrainment fraction at the onset of annular flow is always assumed due to the lack of relevant experimental data. In this paper, the normalized data of the 2006 CHF look-up table (LUT) which has been adopted widely, especially in the nuclear industry, were used. Firstly, the empirical correlations, provided for the onset of annular flow and the limiting quality, were employed. In the valid pressure and mass flux range of these correlations, the selected database from LUT was confirmed. Secondly, the liquid film model was built. The entrainment fraction at the onset of annular flow was obtained when the calculated CHF by the model agreed with the corresponding value in LUT. A parallel look-up table for it was developed. Its correlation including the Weber and the liquid Reynolds number at outlet was proposed. The errors are mostly within ±30%. Finally, its reliability on the other conditions in LUT, which are beyond the valid range of the empirical correlations used for determining the database, was discussed. All the conditions whose errors are outside ±30% of the predictions by the provided correlation were marked in the tables.
Risteski, Ice B.
2010-01-01
In this article, the author discovers a paradox of balancing chemical equations. The many counterexamples illustrate that the considered procedure of balancing chemical equations given in the paper1 is inconsistent. A new complex vector method for paradox resolution is given too. V članku avtor opisuje paradoks pri uravnoteženju kemijskih reakcij. Več primerov dokazuje, da je procedura uravnoteženja kemijskih reakcij v viru1 inkonsistentna. Predstavljena je nova kompleksna vektorska metoda...
A scaling law for the local CHF on the external bottom side of a fully submerged reactor vessel
International Nuclear Information System (INIS)
Cheung, F.B.; Haddad, K.H.; Liu, Y.C.
1997-01-01
A scaling law for estimating the local critical heat flux on the outer surface of a heated hemispherical vessel that is fully submerged in water has been developed from the results of an advanced hydrodynamic CHF model for pool boiling on a downward facing curved heating surface. The scaling law accounts for the effects of the size of the vessel, the level of liquid subcooling, the intrinsic properties of the fluid, and the spatial variation of the local critical heat flux along the heating surface. It is found that for vessels with diameters considerably larger than the characteristic size of the vapor masses, the size effect on the local critical heat flux is limited almost entirely to the effect of subcooling associated with the local liquid head. When the subcooling effect is accounted for separately, the local CHF limit is nearly independent of the vessel size. Based upon the scaling law developed in this work, it is possible to merge, within the experimental uncertainties, all the available local CHF data obtained for various vessel sizes under both saturated and subcooled boiling conditions into a single curve. Applications of the scaling law to commercial-size vessels have been made for various system pressures and water levels above the heated vessel. Over the range of conditions explored in this study, the local CHF limit is found to increase by a factor of two or more from the bottom center to the upper edge of the vessel. Meanwhile, the critical heat flux at a given angular position of the heated vessel is also found to increase appreciably with the system pressure and the water level
International Nuclear Information System (INIS)
Lee, Kwi Lim; Chang, Soon Heung
2009-01-01
An experimental study was performed in the post-CHF condition using R-134a to investigate the effect of spacer grids on post-CHF heat transfer in an annulus channel. The experiments were conducted under the outlet pressures of 1.1 - 2.0 MPa, the mass fluxes of 100 - 400 kg/m 2 s and the inlet temperatures of 25 - 51degC. About 300 data of post-CHF data were obtained in the annular geometry without spacer grids and compared with several post-CHF correlations. The results showed the large prediction uncertainty mainly caused by the cold wall effect, so the empirical correlation for an annulus geometry without spacer grids was developed with the present experimental results. The heat transfer coefficient was calculated based on the heater rod temperature and the saturated vapor property. The average and root-mean-square(RMS) errors of the predictions were 0.17 % and 3.4 %, respectively. The experiments related to the spacer grid effects were performed with an I-type spacer grid and split-swirl mixing vane (with blockage-area ratios of 4.0 and 5.8 %). The spacer grid and mixing vane test results showed the enhancing effect on the heat transfer at the downstream location of the spacers. The experimental results from the spilt-swirl-type grid tests were more effective than the I-type grid tests. This was attributed to enhance the turbulence and increase the heat transfer caused by the mixing vane. (author)
Prognostic impact of peakVO2-changes in stable CHF on chronic beta-blocker treatment.
Frankenstein, L; Nelles, M; Hallerbach, M; Dukic, D; Fluegel, A; Schellberg, D; Katus, H A; Remppis, A; Zugck, C
2007-11-15
Peak oxygen uptake (pVO2) is used for risk stratification in chronic heart failure (CHF), but little is known about the prognostic impact of pVO2-changes in patients on chronic beta-blocker (BBL) therapy. We therefore prospectively evaluated individual pVO2-changes at a 6-month interval in patients all receiving BBL. 194 patients with stable CHF on stable medication were included (V1) and underwent clinical evaluation and exercise testing. Testing was repeated (V2) at 5.7+/-1.5 months after V1 and patients were followed >12 months after V2. Death or hospitalisation due to cardiac reasons was the predefined EP (EPP, end-point positive; n=62; EPN, end-point negative; n=113). Initial characteristics did not differ between EPP and EPN. Multivariate cox regression analysis revealed that change of pVO2 (EPP: -0.6+/-2.6 ml/kg min; EPN: +2.5+/-3.3 ml/kg min; p<0.001) was independent to pVO2, LVEF, NTproBNP and NYHA at V2 for prediction of the combined end-point during follow-up. An increase of pVO2 by 10% was identified as an adequate cut-off value for risk stratification and ROC-analysis showed the significant incremental prognostic value of the determination of pVO2 changes in combination with pVO2. Serial measurements of pVO2 yield additional information for risk stratification in clinically homogenous CHF patients receiving BBL. This is the first study demonstrating this fact within a narrow predefined interval with all patients on BBL.
Dynamic CO₂ inhalation: a novel treatment for CSR-CSA associated with CHF.
Wan, Zhi Hui; Wen, Fang Jing; Hu, Ke
2013-05-01
Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) is very common in patients with chronic congestive heart failure (CHF). A current concept of the key pathophysiological mechanism leading to CSR-CSA is a fluctuation of PaCO2 below and above the apneic threshold. A number of therapeutic approaches for CSR-CSA have been proposed-all with varying success, some of which include various modes of positive airway pressure among other strategies. However, CO2 oscillations seen in CSR-CSA have yet to be looked at as a specific therapeutic target by current treatments. Previous studies have shown that delivery of constant CO2 is efficacious in eliminating CSR-CSA by raising PaCO2, but there are serious concerns about the potential side effects, such as unwanted elevations in ventilation, work of breathing, and sympathetic nerve activity (SNA), and consequently CO2 inhalation therapy has not been recommended as a routine option for therapy. However, recent new studies into CO2 inhalation therapy have been made that may reshape its role as therapeutic. In this review, we will focus on the recent developments of administration of dynamic CO2 in the management of CSR-CSA in CHF patients.
Directory of Open Access Journals (Sweden)
Desimir Vučić
2004-05-01
Full Text Available Sve veća zastupljenost savremenih tehnika digitalnih komunikacija koje primenjuju signale sa malom verovatnoćom presretanja, kao što su signali sa frekvencijskim skakanjem, nameće razvoj novih metoda i algoritama za njihovo izviđanje radi formiranja elektronske slike bojišta. U ovom radu razmatraju se principi i dostignuća u razvoju novih metoda u detekciji, karakterizaciji identifikaciji i eksploataciji ovih sofisticiranih komunikacionih signala u kontekstu elektronskog rata. / The extensive use of modern low probability-of-intercept digital communication signals, such as frequency hopping signals, requires development of new theory and algorithms for their reconnaissance for the purpose of constructing an electronic order of battle. This paper presents some principles and advances in signal processing and analysis technology for the signal interception, characterization, identification and exploitation in the context of electronic warfare.
Effect of CHF3 Plasma Treatment on the Characteristics of SiCOH Low-k Film
International Nuclear Information System (INIS)
Xing Zhenyu; Ye Chao; Yuan Jing; Xu Yijun; Ning Zhaoyuan
2009-01-01
The characteristics of SiCOH low dielectric constant film treated by a trifluromethane (CHF 3 ) electron cyclotron resonance (ECR) plasma was investigated. The flat-band voltage V FB and leakage current of the Cu/SiCOH/Si structure, and the hydrophobic property of the SiCOH film were obtained by the measurements of capacitance-voltage, current-voltage and water contact angle. The structures of the SiCOH film were also analyzed by Fourier transform infrared spectroscopy and atomic force microscopy. The CHF 3 plasma treatment of the SiCOH film led to a reduction in both the flat-band voltage V FB shift and leakage current of the Cu/SiCOH/Si structure, a decrease in surface roughness, and a deterioration of the hydrophobic property. The changes in the film's characteristics were related to the formation of Si-F bond, the increase in Si-OH bond, and the C:F deposition at the surface of the SiCOH film.
International Nuclear Information System (INIS)
Czop, V.; Herer, C.; Souyri, A.; Garnier, J.
1993-09-01
In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l'Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs
Where Would the EUR/CHF Exchange Rate be Without the SNB's Minimum Exchange Rate Policy?
DEFF Research Database (Denmark)
Hanke, Michael; Poulsen, Rolf; Weissensteiner, Alex
2015-01-01
Since its announcement made on September 6, 2011, the Swiss National Bank (SNB) has been pursuing the goal of a minimum EUR/CHF exchange rate of 1.20, promising to intervene on currency markets to prevent the exchange rate from falling below this level.We use a compound option pricing approach...
Forced convective post CHF heat transfer and quenching
International Nuclear Information System (INIS)
Nelson, R.A.
1980-01-01
This paper discusses mechanisms in the post-CHF region which provide understanding and qualitative prediction capability for several current forced convective heat transfer problems. In the area of nuclear reactor safety, the mechanisms are important in the prediction of fuel rod quenches for the reflood phase, blowdown phase, and possibly some operational transients with dryout. Results using the mechanisms to investigate forced convective quenching are presented. Data reduction of quenching experiments is discussed, and the way in which the quenching transient may affect the results of different types of quenching experiments is investigated. This investigation provides an explanation of how minimum wall superheats greater than the homogeneous nucleation temperature result, as well as how these may appear to be either hydrodynamically or thermodynamically controlled. Finally, the results of a parametric study of the effects of the mechanisms upon the LOFT L2-3 hotpin calculation are presented
International Nuclear Information System (INIS)
Hassan, Y.A.
1987-01-01
To date there is only very limited data for non-equilibrium convective film boiling in rod bundle geometries. A recent nine (3 x 3) rod bundle post-critical-flux (CHF) test from the Lehigh University test facility was simulated using RELAP5/MOD2, to assess its capabilities in predicting the overall convective mechanisms in post-CHF heat transfer in rod bundle geometries. The code calculations were compared with experimental data. The code predicted low vapor superheats and void fraction oscillations. A new interfacial heat transfer between the droplet/steam resulted in a reasonable prediction of vapor superheats. A revised dispersed flow film boiling correlation which accounts for the enhancement of steam convective cooling by droplet-induced turbulence was incorporated in the code. Comparison with the data showed a fair agreement
Directory of Open Access Journals (Sweden)
Hendro Nugroho
2014-04-01
Full Text Available Salah satu penelitian ilmu kebumian yang perlu dilakukan untuk membantu upaya mitigasi bencana gempabumi adalah menentukan pusat gempa dengan presisi tinggi. Dalam hal ini ketelitian sangat diperlukan oleh karena adanya heterogenitas materi bumi yang dilewati gelombang gempa dari hiposenter ke stasiun pencatat. Oleh karena itu dengan bantuan model geotomografi (model struktur 3D kecepatan rambat gelombang gempa diharapkan akan dapat diperoleh posisi sumber gempa yang lebih baik. Untuk studi ini daerah penelitian yang diambil adalah Jawa dan sekitarnya, yaitu : 7° LS - 11° LS dan 105° BT - 114° BT. Data yang digunakan adalah waktu tiba gelombang P dari seismogram yang direkam pada seismograf broadband di Indonesia. Penentuan hiposenter menggunakan metoda guided grid search dengan model kecepatan 3D untuk busur Sunda. Hasil penentuan hiposenter gempa dengan pendekatan ini memberikan tingkat kesalahan yang lebih kecil dibandingkan dengan jika digunakan model kecepatan 1D.
Paškov Dugandžija, Gordana
2008-01-01
EEG polisomnografija je značajna metoda za dijagnozu i prognozu oštećenja mozga u nedonošene i donošene novorođenčadi i dojenčadi. Sadrži slijedeće elemente: EEG(elektroencefalografija), EOG( elektrookulografija) , EMG( elektromiografija), EKG (elektrokardiografija), respiracija i video monitoriranje. Primjenjujemo polisomnografsku montažu. To je specifično modificiran način postavljanja elektroda. Koristimo posrebrene pločaste elektrode sa 1 metar savitljivim silikonskim odvodima u šest razl...
Penerapan Metoda Serial Peripheral Interface (SPI pada Rancang Bangun Data Logger berbasis SD card
Directory of Open Access Journals (Sweden)
RATNA SUSANA
2018-03-01
Full Text Available ABSTRAK Serial Peripheral Interface (SPI adalah protokol komunikasi yang dapat digunakan sebagai interface komunikasi antara mikrokontroler dengan SD Card. Dengan menerapkan metoda SPI pada data logger berbasis SD Card, maka dapat diketahui karakteristik protokol komunikasi SPI antara mikrokontroler dengan SD Card. SD Card diformat dengan tipe FAT 16, dan data di dalam SD Card berupa sekumpulan paket data sensor yang diambil secara periodik dan disimpan dalam bentuk file dengan format.csv. Berdasarkan format paket data sensor yang dibuat, dapat dihitungwaktu perekaman data yang diperlukan agar kapasitas SD Card terisi penuh oleh data sensor. Hasil penelitian menunjukkan,bahwa metoda SPI yang diterapkan pada penelitian ini memiliki sifat akan melakukan pemeriksaan berulang pada pin MISO terhadap command yang dikirimkan oleh mikrokontroler melalui pin MOSI. Proses read/write data pada SD Card data logger memiliki keberhasilan 100%, karena SD Card telah terinisialisasi dalam mode SPI melalui perintah reset dan init SD Card. Komunikasi ini dapat dilakukan dengan menggunakan crystal 4 Mhz – 20 Mhz. Untuk pengujian konfigurasi SPI, hanya Independent Slave Configuration yang dapat digunakan pada komunikasi SPI dengan 2 SD card sebagai slave. Kata kunci: Serial Peripheral Interface (SPI, Data Logger, SD card, FAT16 ABSTRACT Serial Peripheral Interface (SPI is a communication protocol that can be applied as a communication interface between microcontroller to SD Card. By implementing the SPI method to a data logger based on SD Card, it can be known the characteristics of the SPI communications protocol between microcontroller to SD Card. SD Card formatted in FAT 16 type, and data on the SD Card is the form of sensor data packets collection which be captured periodically and saved in .csv format file. Based on the sensor data packet format is created, it can be calculated recording time data required so that the SD Card capacity completely filled by the
Primjena spektrometrijskih metoda u analizi metalurških uzoraka
Directory of Open Access Journals (Sweden)
Anita Štrkalj
2016-07-01
Full Text Available Instrumentalne metode analize nezamjenjive su u znanstvenim istraživanjima, a sve više i u praksi gdje se zahtijeva što brže dobivanje rezultata, kao i što veća točnost. U metalurškoj praksi već se dulji niz godina primjenjuju spektrometrijske metode analize i to najčešće optička emisijska spektrometrija s izravnim očitanjem. Međutim koncentracija pojedinih legirnih elemenata u suvremenim metalnim materijalima vrlo je niska, često niža od granice detekcije optičkih emisijskih spektrometara s izravnim očitanjem. U ovom radu određivana je koncentracija bora u nodularnom lijevu primjenom optičke emisijske spektrometrije s izravnim očitanjem (OES, optičke emisijske spektrometrije s induktivno spregnutom plazmom (ICP-OES te atomske apsorpcijske spektrometrije s grafitnom tehnikom (AAS-GF. Dobiveni rezultati pokazali su da se optička emisijska spektrometrija s izravnim očitanjem i optička emisijska spektrometrija s induktivno spregnutom plazmom mogu primijeniti za određivanje bora u ispitivanim uzorcima (tablica 1. Ako se zahtijeva vrlo točna analiza, a posebno ako se radi o vrlo niskim koncentracijama, optička emisijska spektrometrija s induktivno spregnutom plazmom pogodnija je metoda, uz uvjet da su uzorci pravilno pripremljeni. Atomska apsorpcijska spektrometrija s grafitnom tehnikom nije pogodna za određivanje bora u uzorcima ovog tipa. Tijekom provođenja analize dodatna pažnja usmjerena je na eliminaciju negativnog utjecaja grafitne kivete na rezultat analize. Osim toga, u radu je praćen utjecaj načina otapanja uzoraka na rezultate analize bora spomenutim metodama. Rezultati su pokazali da pažljiva priprema uzoraka u zatvorenom sustavu pridonosi točnijem rezultatu analize.
International Nuclear Information System (INIS)
Rui Shibao; Xia Chaohoung; Cheng Guanghua
2009-01-01
Objective: To study the changes of plasma levels of endothelin (ET), calcitonin gene related peptide (CGRP), neuropeptide Y (NPY) and adrenomedullin (ADM) both before and after treatment in patients with CHF. Methods: Plasma levels of ET, CGRP, NPY and ADM were determined with RIA both before and after treatment in 79 patients with CHF and once in 31 controls. The 79 patients were of two groups: Group A cardiac function Grade III or better, n=45, Group B, cardiac function Grade IV, n=34 with 3 deaths. Results: Before treatment, the plasma levels of ET and CGRP were significantly higher in both groups of patients than those in controls, with higher values in more severe cases. After treatment,the levels dropped markedly but remained significantly higher than those in controls. Most remarkably was that in the three deaths: the CGRP levels before treatment, though higher than those in the controls, were significantly lower than the mean value in Group B patients as a whole, and dropped furthur to below those in controls as the patients deteriorated. With NPY and ADM, before treatment the plasma levels in both groups of patients were also significantly higher than those in controls. The levels also dropped markedly after treatment, but still remained significantly higher than those in controls. Again, in the 3 deaths, the plasma levels of ADM were significantly lower than the mean value of Group B patients and were not much different from those in controls (P>0.05) and dropped furthur to even below the levels of controls as the patients deteriorated. Conclusion: Changes of plasma levels of ET and NPY might reflect the severity of the disease process of CHF while changes of plasma CGRP and ADM levels might even be of prognostic value. (authors)
Olah, George A; Surya Prakash, G K; Rasul, Golam
2008-07-16
The structures and energies of the carbocations C 4H 7 (+) and C 5H 9 (+) were calculated using the ab initio method. The (13)C NMR chemical shifts of the carbocations were calculated using the GIAO-CCSD(T) method. The pisigma-delocalized bisected cyclopropylcarbinyl cation, 1 and nonclassical bicyclobutonium ion, 2 were found to be the minima for C 4H 7 (+) at the MP2/cc-pVTZ level. At the MP4(SDTQ)/cc-pVTZ//MP2/cc-pVTZ + ZPE level the structure 2 is 0.4 kcal/mol more stable than the structure 1. The (13)C NMR chemical shifts of 1 and 2 were calculated by the GIAO-CCSD(T) method. Based on relative energies and (13)C NMR chemical shift calculations, an equilibrium involving the 1 and 2 in superacid solutions is most likely responsible for the experimentally observed (13)C NMR chemical shifts, with the latter as the predominant equilibrating species. The alpha-methylcyclopropylcarbinyl cation, 4, and nonclassical bicyclobutonium ion, 5, were found to be the minima for C 5H 9 (+) at the MP2/cc-pVTZ level. At the MP4(SDTQ)/cc-pVTZ//MP2/cc-pVTZ + ZPE level ion 5 is 5.9 kcal/mol more stable than the structure 4. The calculated (13)C NMR chemical shifts of 5 agree rather well with the experimental values of C 5H 9 (+).
A.S. Grustam (Andrija); Vrijhoef, H.J.M. (Hubertus J. M.); R. Koymans (Ron); Hukal, P. (Philipp); J.L. Severens (Hans)
2017-01-01
textabstractBackground: The purpose of this study is to assess the Business-to-Consumer (B2C) model for telemonitoring patients with Chronic Heart Failure (CHF) by analysing the value it creates, both for organizations or ventures that provide telemonitoring services based on it, and for society.
Assessment of correlations and models for the prediction of CHF in water subcooled flow boiling
Celata, G. P.; Cumo, M.; Mariani, A.
1994-01-01
The present paper provides an analysis of available correlations and models for the prediction of Critical Heat Flux (CHF) in subcooled flow boiling in the range of interest of fusion reactors thermal-hydraulic conditions, i.e. high inlet liquid subcooling and velocity and small channel diameter and length. The aim of the study was to establish the limits of validity of present predictive tools (most of them were proposed with reference to light water reactors (LWR) thermal-hydraulic studies) in the above conditions. The reference dataset represents almost all available data (1865 data points) covering wide ranges of operating conditions in the frame of present interest (0.1 less than p less than 8.4 MPa; 0.3 less than D less than 25.4 mm; 0.1 less than L less than 0.61 m; 2 less than G less than 90.0 Mg/sq m/s; 90 less than delta T(sub sub,in) less than 230 K). Among the tens of predictive tools available in literature four correlations (Levy, Westinghouse, modified-Tong and Tong-75) and three models (Weisman and Ileslamlou, Lee and Mudawar and Katto) were selected. The modified-Tong correlation and the Katto model seem to be reliable predictive tools for the calculation of the CHF in subcooled flow boiling.
Kapologwe, Ntuli A; Kagaruki, Gibson B; Kalolo, Albino; Ally, Mariam; Shao, Amani; Meshack, Manoris; Stoermer, Manfred; Briet, Amena; Wiedenmayer, Karin; Hoffman, Axel
2017-04-27
Introduction of a health insurance scheme is one of the ways to enhance access to health care services and to protect individuals from catastrophic health expenditures. Little is known on the influence of socio-demographic and social marketing strategies on enrollment and re-enrollment in the Community Health Fund/Tiba Kwa Kadi (CHF/TIKA) in Tanzania. This cross-sectional study employed quantitative methods for data collection between November 2014 and March 2015 in Singida and Shinyanga regions. Relationship between variables was obtained through Chi-square test and multivariate logistic regression. We recruited 496 participants in the study. Majority (92.7%) of participants consented to participate, with 229 (49.8%) and 231 (50.2%) members and non members of CHF/TIKA respectively. Majority (90.9%) were aware of CHF/TIKA. Majority of CHF/TIKA members and non-members (90% and 68.3% respectively) reported health facility-based sensitization as the most common social marketing approach employed to market the CHF/TIKA. The most popular marketing strategies in the country including traditional dances, football games, radio, television, news papers, and mosques/church were reported by few CHF and non CHF members. Multivariate Logistic regression models revealed no significant association between social marketing strategies and enrollment, but only socio-demographics; including marital status (AOR = 2.0, 95% CI 1.1-3.8) and family size (household with ≥ 6 members) (AOR = 1.5, 95% CI 1.0-2.5), were significant factors associated with enrollment/re-enrollment rate. This study indicated that low level of utilization of available social marketing strategies and socio-demographic factors are the barriers for attracting members to join the schemes. There is a need for applying various social marketing strategies and considering different facilitating and impending socio-demographic factors for the growth and sustainability of the scheme as we move towards
International Nuclear Information System (INIS)
Sturgis, J.C.; Mudawar, I.
1999-01-01
An experimental study was undertaken to examine the enhancement in critical heat flux (CHF) provided by streamwise curvature. Curved and straight rectangular flow channels were fabricated with identical 5.0 x 2.5 mm cross sections and heated lengths of 101.6 mm in which the heat was applied to only one wall--the concave wall (32.3 mm radius) in the curved channel and a side wall in the straight. Tests were conducted using FC-72 liquid with mean inlet velocity and outlet subcooling of 0.25 to 10 m s -1 and 3 to 29 C, respectively. Centripetal acceleration for curved flow reached 315 times earth's gravitational acceleration. Critical heat flux was enhanced due to flow curvature at all conditions but the enhancement decreased with increasing subcooling. For near-saturated conditions, the enhancement was approximately 60% while for highly subcooled flow it was only 20%. The causes for the enhancement were identified as (1) increased pressure on the liquid-vapor interface at wetting fronts, (2) buoyancy forces and (3) increased subcooling at the concave wall. Flow visualization tests were conducted in transparent channels to explore the role of buoyancy forces in enhancing the critical heat flux. These forces were observed to remove vapor from the concave wall and distribute it throughout the cross section. Vapor removal was only effective at near-saturated conditions, yielding the observed substantial enhancement in CHF relative to the straight channel
Papadimitriou, Vassileios C; Lazarou, Yannis G; Talukdar, Ranajit K; Burkholder, James B
2011-01-20
Rate coefficients, k, for the gas-phase reactions of Cl atoms and NO(3) radicals with 2,3,3,3-tetrafluoropropene, CF(3)CF═CH(2) (HFO-1234yf), and 1,2,3,3,3-pentafluoropropene, (Z)-CF(3)CF═CHF (HFO-1225ye), are reported. Cl-atom rate coefficients were measured in the fall-off region as a function of temperature (220-380 K) and pressure (50-630 Torr; N(2), O(2), and synthetic air) using a relative rate method. The measured rate coefficients are well represented by the fall-off parameters k(0)(T) = 6.5 × 10(-28) (T/300)(-6.9) cm(6) molecule(-2) s(-1) and k(∞)(T) = 7.7 × 10(-11) (T/300)(-0.65) cm(3) molecule(-1) s(-1) for CF(3)CF═CH(2) and k(0)(T) = 3 × 10(-27) (T/300)(-6.5) cm(6) molecule(-2) s(-1) and k(∞)(T) = 4.15 × 10(-11) (T/300)(-0.5) cm(3) molecule(-1) s(-1) for (Z)-CF(3)C═CHF with F(c) = 0.6. Reaction product yields were measured in the presence of O(2) to be (98 ± 7)% for CF(3)C(O)F and (61 ± 4)% for HC(O)Cl in the CF(3)CF═CH(2) reaction and (108 ± 8)% for CF(3)C(O)F and (112 ± 8)% for HC(O)F in the (Z)-CF(3)CF═CHF reaction, where the quoted uncertainties are 2σ (95% confidence level) and include estimated systematic errors. NO(3) reaction rate coefficients were determined using absolute and relative rate methods. Absolute measurements yielded upper limits for both reactions between 233 and 353 K, while the relative rate measurements yielded k(3)(295 K) = (2.6 ± 0.25) × 10(-17) cm(3) molecule(-1) s(-1) and k(4)(295 K) = (4.2 ± 0.5) × 10(-18) cm(3) molecule(-1) s(-1) for CF(3)CF═CH(2) and (Z)-CF(3)CF═CHF, respectively. The Cl-atom reaction with CF(3)CF═CH(2) and (Z)-CF(3)CF═CHF leads to decreases in their atmospheric lifetimes and global warming potentials and formation of a chlorine-containing product, HC(O)Cl, for CF(3)CF═CH(2). The NO(3) reaction has been shown to have a negligible impact on the atmospheric lifetimes of CF(3)CF═CH(2) and (Z)-CF(3)CF═CHF. The energetics for the reaction of Cl, NO(3), and OH with CF
Electron and Negative Ion Densities in C2F6 and CHF3 Containing Inductively Coupled Discharges
International Nuclear Information System (INIS)
HEBNER, GREGORY A.; MILLER, PAUL A.
1999-01-01
Electron and negative ion densities have been measured in inductively coupled discharges containing C 2 F 6 and CHF 3 . Line integrated electron density was determined using a microwave interferometer, negative ion densities were inferred using laser photodetachment spectroscopy, and electron temperature was determined using a Langmuir probe. For the range of induction powers, pressures and bias power investigated, the electron density peaked at 9 x 10 12 cm -2 (line-integrated) or approximately 9 x 10 11 cm -3 . The negative ion density peaked at approximately 1.3 x 10 11 cm -3 . A maximum in the negative ion density as a function of induction coil power was observed. The maximum is attributed to a power dependent change in the density of one or more of the potential negative ion precursor species since the electron temperature did not depend strongly on power. The variation of photodetachment with laser wavelength indicated that the dominant negative ion was F - . Measurement of the decay of the negative ion density in the afterglow of a pulse modulated discharge was used to determine the ion-ion recombination rate for CF 4 , C 2 F 6 and CHF 3 discharges
CHF during flow rate, pressure and power transients in heated channels
International Nuclear Information System (INIS)
Celata, G.P.; Cumo, M.
1987-01-01
The behaviour of forced two-phase flows following inlet flow rate, pressure and power transients is presented here with reference to experiments performed with a R-12 loop. A circular duct, vertical test section (L = 2300 mm; D = 7.5 mm) instrumented with fluid (six) and wall (twelve) thermocouples has been employed. Transients have been carried out performing several values of flow decays (exponential decrease), depressurization rates (exponential decrease) and power inputs (step-wise increase). Experimental data have shown the complete inadequacy of steady-state critical heat flux correlations in predicting the onset of boiling crisis during fast transients. Data analysis for a better theoretical prediction of CHF occurrence during transient conditions has been accomplished, and design correlations for critical heat flux and time-to-crisis predictions have been proposed for the different types of transients
An independent assessment of Groeneveld et al.'s 1995 CHF look-up table
International Nuclear Information System (INIS)
Baek, W.-P.; Kim, H.-C.; Heung Chang, S.
1997-01-01
The prediction capability of the 1995 CHF look-up table (Groeneveld D.C., et al., Nucl. Eng. Des. 163 (1996) 1-23) is independently assessed based on the KAIST data base consisting of 10822 data for uniformly-heated, vertical, round tubes. This confirms the error statistics for the heat balance method reported by Groeneveld et al. and shows overall average and RMS errors of 4.2 and 36.7%, respectively, for the direct substitution method. The new 1995 table shows better prediction capability than the 1986 AECL-UO table (Groeneveld et al., 1986), especially for the low-pressure, low-flow region. The error analysis indicates the length effect even for significantly long tubes. (orig.)
Albert, S.; Bauerecker, S.; Bekhtereva, E. S.; Bolotova, I. B.; Hollenstein, H.; Quack, M.; Ulenikov, O. N.
2018-05-01
We report high-resolution (? 0.001 cm-1) Fourier Transform Infrared spectra of fluoroform (CHF3) including the pure rotational (far infrared or THz) range (28-65 cm-1), the ν3 fundamental (? = 700.099 cm-1), as well as the associated "hot' band 2ν3 - ν3 (? = 699.295 cm-1) and the 'atmospheric window' range 1100-1250 cm-1 containing the strongly coupled polyad of the levels ν2, ν5 and ν3 + ν6, at room temperature and at 120 K using the collisional cooling cell coupled to our Bruker IFS 125 HR prototype (ZP2001) spectrometer and Bruker IFS 125 HR ETH-SLS prototype at the Swiss Light Source providing intense synchrotron radiation. The pure rotational spectra provide new information about the vibrational ground state of CHF3, which is useful for further analysis of excited vibrational states. The ν3 fundamental band is re-investigated together with the corresponding 'hot' band 2ν3 - ν3 leading to an extension of the existing line lists up to 4430 transitions with ? = 66 for ν3 and 1040 transitions with ? = 43 for 2ν3 - ν3. About 6000 transitions were assigned to rovibrational levels in the polyad ν2/ν5/ν3 + ν6 with ? = 63 for ν2 (? = 1141.457 cm-1), ? = 63 for ν5 (? = 1157.335 cm-1) and ? = 59 for ν3 + ν6 (? = 1208.771 cm-1)(? = ? in each case). The resonance interactions between the ν2, ν5 and ν3 + ν6 states have been taken into account providing an accurate set of effective hamiltonian parameters, which reproduce the experimental results with an accuracy close to the experimental uncertainties (with a root mean square deviation drms = 0.00025 cm-1). The analysis is further extended to the ν4 fundamental (? = 1377.847 cm-1) interacting with 2ν3 (? = 1399.394 cm-1). The results are discussed in relation to the importance of understanding the spectra of CHF3 as a greenhouse gas and as part of our large effort to measure and understand the complete spectrum of CHF3 from the far-infrared to the near-infrared as a prototype for intramolecular
International Nuclear Information System (INIS)
Kam, Dong Hoon; Park, Hae Min; Choi, Young Jae; Jeong, Yong Hoon
2015-01-01
Heat transfer performance of downward-facing conditions are important especially in severe accident mitigation strategy (IVR-ERVC and Core-catcher). Heat transfer limit, in other word, critical heat flux (CHF) is important value in this basis to guarantee the integrity of the system. For the application point of view in nuclear power plant, carbon steel surface should also be considered since reactor pressure vessel (RPV) in IVR-ERVC strategy consists of carbon steel, and core-catcher in EU-APR1400 is also composed of carbon steel. In this perspective, carbon steel surface was used in previous studies. In this study, CHF of both stainless steel and carbon steel material were measured under pool boiling condition with various inclination angles and dimensions. There was a width effect as angle increases, but it disappeared as approached to horizontally downward condition. Besides, there was almost no length effect for both of the width since the size of coalesced bubble was far smaller than the length of short test section (100 mm). SA 508 showed enhanced results at high angles for 40 mm-width case even though no oxidation occurred on the surface during the experiments
Energy Technology Data Exchange (ETDEWEB)
Kam, Dong Hoon; Park, Hae Min; Choi, Young Jae; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)
2015-05-15
Heat transfer performance of downward-facing conditions are important especially in severe accident mitigation strategy (IVR-ERVC and Core-catcher). Heat transfer limit, in other word, critical heat flux (CHF) is important value in this basis to guarantee the integrity of the system. For the application point of view in nuclear power plant, carbon steel surface should also be considered since reactor pressure vessel (RPV) in IVR-ERVC strategy consists of carbon steel, and core-catcher in EU-APR1400 is also composed of carbon steel. In this perspective, carbon steel surface was used in previous studies. In this study, CHF of both stainless steel and carbon steel material were measured under pool boiling condition with various inclination angles and dimensions. There was a width effect as angle increases, but it disappeared as approached to horizontally downward condition. Besides, there was almost no length effect for both of the width since the size of coalesced bubble was far smaller than the length of short test section (100 mm). SA 508 showed enhanced results at high angles for 40 mm-width case even though no oxidation occurred on the surface during the experiments.
Computer Security: Do you have 30 kCHF pocket money?
Stefan Lueders, Computer Security Team
2015-01-01
I am not kidding. Do you have 30,000 CHF to spare? Give it to me, so that I can lose it. It won’t even be well invested. We will just give it away by mistake. An easy mistake, some think. A “gentlemen’s” blunder. Unimportant and, really, not at all a big deal. But, of course, that's wrong - and expensive. Here is my story. Recently, a student working at CERN was supposed to make a sophisticated simulation of thermal conductivity within a metallic structure, the resulting mechanic stress and the electromagnetic field variations within it. All of his teammates were using a commercial simulation package named - for the sake of brevity - “AllSIM”. But our student failed to download AllSIM from DFS onto his office PC, since that wasn’t where he wanted to use it. He wanted to install it on his laptop so that he could work on his simulation while travelling. However, the CERN AllSIM installation would not allow for this,...
CHF predictor derived from a 3D thermal-hydraulic code and an advanced statistical method
International Nuclear Information System (INIS)
Banner, D.; Aubry, S.
2004-01-01
A rod bundle CHF predictor has been determined by using a 3D code (THYC) to compute local thermal-hydraulic conditions at the boiling crisis location. These local parameters have been correlated to the critical heat flux by using an advanced statistical method based on spline functions. The main characteristics of the predictor are presented in conjunction with a detailed analysis of predictions (P/M ratio) in order to prove that the usual safety methodology can be applied with such a predictor. A thermal-hydraulic design criterion is obtained (1.13) and the predictor is compared with the WRB-1 correlation. (author)
Energy Technology Data Exchange (ETDEWEB)
Jeon, M. H.; Kang, S. K.; Park, J. Y.; Yeom, G. Y. [Sungkyunkwan University, Suwon (Korea, Republic of)
2011-11-15
Nanoscale SiO{sub 2} contact holes were etched by using C{sub 4}F{sub 8}/CHF{sub 3}/O{sub 2}/Ar gas mixtures in dual frequency capacitively coupled plasmas (DF-CCPs) where a 60-MHz source power was applied to the top electrode while a 2-MHz bias power was applied to the bottom electrode. The initial increase in the CHF{sub 3} gas flow rate at a fixed CHF{sub 3}+O{sub 2} flow rate increased the SiO{sub 2} etch rate as well as SiO{sub 2} etch selectivity over that of the amorphous carbon layer (ACL). When the high-frequency (HF) power was increased both SiO{sub 2} etch rate and the etch selectivity over ACL were increased. For a 300 W/500 W power ratio of 60-MHz HF power/ 2-MHz low-freqeuncy (LF) and a gas mixture of Ar (140 sccm) /C{sub 4}F{sub 8} (30 sccm) /CHF{sub 3} (25 sccm) /O{sub 2} (5 sccm) while maintaining 20 mTorr, an anisotropic etch profile with an SiO{sub 2} etch rate of 3350 A/min and an etch selectivity of higher than 6 over ACL could be obtained.
Energy Technology Data Exchange (ETDEWEB)
Ito, Tomoko; Karahashi, Kazuhiro; Fukasawa, Masanaga; Tatsumi, Tetsuya; Hamaguchi, Satoshi [Center for Atomic and Molecular Technologies, Osaka University, Osaka 565-0871 (Japan); Semiconductor Technology Development Division, SBG, CPDG, Sony Corporation, Atsugi, Kanagawa 243-0014 (Japan); Center for Atomic and Molecular Technologies, Osaka University, Osaka 565-0871 (Japan)
2011-09-15
Hydrogen in hydrofluorocarbon plasmas plays an important role in silicon nitride (Si{sub 3}N{sub 4}) reactive ion etching. This study focuses on the elementary reactions of energetic CHF{sub 2}{sup +} and CH{sub 2}F{sup +} ions with Si{sub 3}N{sub 4} surfaces. In the experiments, Si{sub 3}N{sub 4} surfaces were irradiated by monoenergetic (500-1500 eV) beams of CHF{sub 2}{sup +} and CH{sub 2}F{sup +} ions as well as hydrogen-free CF{sub 2}{sup +} and CF{sup +} ions generated by a mass-selected ion beam system and their etching yields and surface properties were examined. It has been found that, when etching takes place, the etching rates of Si{sub 3}N{sub 4} by hydrofluorocarbon ions, i.e., CHF{sub 2}{sup +} and CH{sub 2}F{sup +}, are higher than those by the corresponding fluorocarbon ions, i.e., CF{sub 2}{sup +} and CF{sup +}, respectively. When carbon film deposition takes place, it has been found that hydrogen of incident hydrofluorocarbon ions tends to scavenge fluorine of the deposited film, reducing its fluorine content.
Application of ANNS in tube CHF prediction: effect on neuron number in hidden layer
International Nuclear Information System (INIS)
Han, L.; Shan, J.; Zhang, B.
2004-01-01
Prediction of the Critical Heat Flux (CHF) for upward flow of water in uniformly heated vertical round tube is studied with Artificial Neuron Networks (ANNs) method utilizing different neuron number in hidden layers. This study is based on thermal equilibrium conditions. The neuron number in hidden layers is chosen to vary from 5 to 30 with the step of 5. The effect due to the variety of the neuron number in hidden layers is analyzed. The analysis shows that the neuron number in hidden layers should be appropriate, too less will affect the prediction accuracy and too much may result in abnormal parametric trends. It is concluded that the appropriate neuron number in two hidden layers should be [15 15]. (authors)
UTILITATEA ANALIZEI RELAŢIEI COST-VOLUM-PROFIT ÎN METODA DIRECT-COSTING PENTRU PROCESUL DECIZIONAL
Directory of Open Access Journals (Sweden)
Nelea CHIRILOV
2016-12-01
Full Text Available În acest articol este analizată relaţia cost-volum-profit în scopul optimizării profitului şi fundamentării unor decizii economice optime. Sunt prezentate studii de caz metodologice menite să evidenţieze necesitatea indicatorilor: pragul de rentabilitate, marja de contribuţie, rezerva stabilităţii financiare, volumul vânzărilor necesar obţinerii profitului dorit, preţul marginal. Rezultatele obţinute sunt prezentate şi analizate de autori. Articolul se încheie cu concluziile autorilor privind avantajele oferite de calculele şi analizele ce pot fi efectuate pe baza relaţiei cost-volum-profit în metoda direct-costing pentru procesul decizional.THE UTILITY OF ANALYZING COST-VOLUME-PROFIT RELATIONSHIP THROUGH THE DIRECT-COSTING METHOD FOR DECISION MAKING PROCESSIn this article it is analyzed the cost-volume-profit relationship with the aim of profit optimization and elaboration of optimum economic decisions. The statement also reflects methodological case studies which highlight the necessity of the following indicators: break-even point, contribution margin, reserve of financial stability, sales volume required for obtaining target profit, marginal price. The results are presented and are analyzed by authors. The article ends up with the conclusions of the authors with regards to advantages provided by the calculations and analysis which can be performed on the basis of cost-volume-profit relationship through the direct-costing method for decision making process.
Directory of Open Access Journals (Sweden)
Dušan Rajić
2009-07-01
Full Text Available Na primeru izabranih sredstava lične NHB zaštite demonstrirana je primena metode procene kompatibilnosti, kao vrlo bitne taktičko-tehničke karakteristike za svako novouvedeno sredstvo naoružanja i vojne opreme (NVO u Vojsci Srbije. Utvrđeno je da zaštitno filtrirajuće odelo, zaštitni laki ogrtač i zaštitne rukavice ispunjavaju postavljene kriterijume kompatibilnosti. Opisana metoda provere kompatibilnosti može da se primenjuje i na druga sredstva NVO u fazama razvoja, proizvodnje i eksploatacije. / The selected personal NBC protection devices have served as an example for demonstrating the application of the compatibility evaluation method as a very important tactical-technical characteristic of each newly introduced item of weapon and military equipment in the Serbian army. It has been determined that a filtering protective suit, a light protective coat and protective gloves meet the required criteria of compatibility. The described method of testing compatibility can be also applied to other weapons and military equipment in stages of development, production and exploitation.
International Nuclear Information System (INIS)
Watson-Wright, W.M.; Wilkinson, M.
1987-01-01
The authors utilized a muscle slice technique to compare the ontogeny of cell surface β-adrenergic receptor binding in soleus and extensor digitorum longus (EDL) muscles of male Golden Syrian (GS) and Canadian Hybrid Farms 147 (CHF 147) dystrophic hamsters. Binding of the β-adrenergic antagonist, [ 3 H] CGP-12177 (CGP), to GS muscle slices was reversible, saturable, stereospecific and of high affinity. Bmax was higher in the soleus (2.57+/-.12 fmol/mg wet wt) than in the EDL (1.61+/-.17 fmol/mg wet wt) of adult animals while affinities were similar (0.35+/-.06 and 0.24+/-.04 nM respectively). No differences in binding characteristics were seen in EDL of GS compared to CHF 147 animals. In soleus slices from GS hamsters, Bmax was highest at 16 days of age (5.72+/-0.26 fmol/mg), decreased between 16 and 29 days and remained constant until 300 days (2.51+/-0.52 fmol/mg). In dystrophic soleus slices, Bmax was also higher at 16 days than at any other age but receptor number decreased gradually, remaining higher than in GS until 90 days of age (p<0.05). The failure of β-adrenergic receptor number to decrease at a normal rate may be implicated in the pathogenesis of hamster polymyopathy. 21 references, 5 figures, 1 table
Grustam, Andrija S; Vrijhoef, Hubertus J M; Koymans, Ron; Hukal, Philipp; Severens, Johan L
2017-10-11
The purpose of this study is to assess the Business-to-Consumer (B2C) model for telemonitoring patients with Chronic Heart Failure (CHF) by analysing the value it creates, both for organizations or ventures that provide telemonitoring services based on it, and for society. The business model assessment was based on the following categories: caveats, venture type, six-factor alignment, strategic market assessment, financial viability, valuation analysis, sustainability, societal impact, and technology assessment. The venture valuation was performed for three jurisdictions (countries) - Singapore, the Netherlands and the United States - in order to show the opportunities in a small, medium-sized, and large country (i.e. population). The business model assessment revealed that B2C telemonitoring is viable and profitable in the Innovating in Healthcare Framework. Analysis of the ecosystem revealed an average-to-excellent fit with the six factors. The structure and financing fit was average, public policy and technology alignment was good, while consumer alignment and accountability fit was deemed excellent. The financial prognosis revealed that the venture is viable and profitable in Singapore and the Netherlands but not in the United States due to relatively high salary inputs. The B2C model in telemonitoring CHF potentially creates value for patients, shareholders of the service provider, and society. However, the validity of the results could be improved, for instance by using a peer-reviewed framework, a systematic literature search, case-based cost/efficiency inputs, and varied scenario inputs.
A comparison of the CHF between tubes and annuli under PWR thermal-hydraulic conditions
Energy Technology Data Exchange (ETDEWEB)
Herer, C. [RRAMATOME EP/TC, Paris (France); Souyri, A. [EdF DER/RNE/TTA, Chatou (France); Garnier, J. [CEA DRN/DTP/STR/LETC, Grenoble (France)
1995-09-01
Critical Heat Flux (CHF) tests were carried out in three tubes with inside diameters of 8, 13, and 19.2 mm and in two annuli with an inner tube of 9.5 mm and an outer tube of 13 or 19.2 mm. All axial heat flux distributions in the test sections were uniform. The coolant fluid was Refrigerant 12 (Freon-12) under PWR thermal-hydraulic conditions (equivalent water conditions - Pressure: 7 to 20 MPa, Mass Velocity: 1000 to 6000 kg/m2/s, Local Quality: -75% to +45%). The effect of tube diameter is correlated for qualities under 15%. The change from the tube to the annulus configuration is correctly taken into account by the equivalent hydraulic diameter. Useful information is also provided concerning the effect of a cold wall in an annulus.
Directory of Open Access Journals (Sweden)
Rahma Yulia
2016-07-01
Full Text Available Telah dilakukan penelitian analisis kadar kofein kopi luwak dengan variasi jenis kopi, spesies luwak dan cara pengolahan dengan metoda TLC Scanner. Analisis dilakukan dengan menggunakan 8 sampel kopi luwak R.Ab.K ; R.Ab.B ; R.Ph.K ; R.Ph.B ; A.Ab.K ; A.Ab.B ; A.Ph.K ; A.Ph.B yang diekstraksi dengan pelarut diklorometana ( DCM . Pemisahan dengan KLT dilakukan dengan fasa diam plat silika gel GF254 dan fasa gerak campuran diklorometana : metanol ( 9,5 : 0,5 . Kadar kofein dihitung dengan menggunakan persamaan regresi y = 2715,112 + 4,389x dan memberikan persentase kadar berturut-turut 1,91 ; 2,04 ; 1,30 ; 1,89 ; 1,29 ; 1,45 ; 1,25 ; 1,42 %. Kadar kofein paling tinggi diberikan oleh kopi robusta yang diberikan pada luwak A. binturong dan diolah secara basah dengan persentase 2,04 %. Sedangkan kadar kofein paling rendah diberikan oleh kopi arabika yang diberikan pada luwak P. hermophroditus dengan persentase 1,25 %. Pengolahan data dengan statistik anova tiga jalan SPSS 21 menunjukkan hasil bahwa jenis kopi, variasi luwak dan cara pengolahan memberikan pengaruh yang signifikan terhadap kadar kofein dengan p < 0,05.
Zielińska, Agnieszka; Paradowska, Katarzyna; Jakowski, Jacek; Wawer, Iwona
2008-02-01
13C CP MAS NMR spectra of the flavonoids: morin, kaempferol, 3,7-dihydroxyflavone, tricin and isoflavones: genistein and formononetin were recorded to characterize solid-state conformations. Intramolecular hydrogen bonds forming five-, six- and seven-membered rings are present in the two morin molecules in the crystals - their 13C resonances have been assigned with the aid of the calculated shielding constants. Linear relationships between the calculated shielding constants σDFT (ppm) and chemical shifts ( δCPMAS, ppm) were obtained for all studied compounds. Higher correlation coefficients suggest that the conformation with "clockwise" orientation of both OH groups is more probable in the solid 3,7-dihydroxyflavone, whereas in the solid formononetin the OH and OCH 3 substituents are directed "anticlockwise". The barrier to the rotation of phenyl ring B decreases in the order: morin (2'-OH, 3-OH) > kaempferol (3-OH) > tricin.
Directory of Open Access Journals (Sweden)
Havva Aksu
2008-01-01
Full Text Available Six novel 3-alkyl(aryl-4-(p-nitrobenzoylamino-4,5-dihydro-1H-1,2,4-triazol-5- ones (2a-f were synthesized by the reactions of 3-alkyl(aryl-4-amino-4,5-dihydro-1H- 1,2,4-triazol-5-ones (1a-f with p-nitrobenzoyl chloride and characterized by elemental analyses and IR, 1H-NMR, 13C-NMR and UV spectral data. The newly synthesized compounds 2 were titrated potentiometrically with tetrabutylammonium hydroxide in four non-aqueous solvents such as acetone, isopropyl alcohol, tert-butyl alcohol and N,Ndimethylformamide, and the half-neutralization potential values and the corresponding pKa values were determined for all cases. Thus, the effects of solvents and molecular structure upon acidity were investigated. In addition, isotropic 1H and 13C nuclear magnetic shielding constants of compounds 2 were obtained by the gauge-including-atomic-orbital (GIAO method at the B3LYP density functional level. The geometry of each compound has been optimized using the 6-311G basis set. Theoretical values were compared to the experimental data. Furthermore, these new compounds and five recently reported 3-alkyl-4-(2- furoylamino-4,5-dihydro-1H-1,2,4-triazol-5-ones (3a-c,e,f were screened for their antioxidant activities.
Spontaneous condensation of CHF2Cl vapour at high reduced pressures
International Nuclear Information System (INIS)
Bier, K.; Ehrler, F.; Kissau, G.; Lippig, V.; Schorsch, R.
1977-01-01
Spontaneous condensation at high reduced pressures was investigated in stationary jets of difluoromonochlormethane vapour (refrigerant R 22) expanding within an annular Laval nozzle. The onset of condensation in the so-called Wilson point was determined by measuring the static pressure along the nozzle axis. For 33 expansions carried out with the same nozzle geometry at different stagnation conditions - with dew points ranging from 32 to 64 per cent of the critical pressure - the Wilson points can be represented by a common Wilson line, which can be extended to the critical point. Considering the real gas properties of the supersaturated vapour, one obtains nucleation rates for the states on the measured Wilson line, which are considerably lower than those resulting from the usual ideal-gas calculation, the difference amounting from 4 to 9 orders of magnitude in the investigated region. A comparison with the collision rate of single molecules shows that the nucleation rates calculated for the real gas according to the classical Volmer-Frenkel thoery are plausible. An adequate interpretation of the experimental results on CHF 2 Cl with the Lothe-Pound theory, however, seems not possible, since the nucleation rate due to that theory would nearly attain and - at higher densities - even exceed the molecular collision rate. (orig.) [de
Directory of Open Access Journals (Sweden)
Rodrigo P. Franco
2011-09-01
Full Text Available Degenerative myxomatous mitral valve (DMMV is a heart disease of high incidence in small animal clinical medicine, affecting mainly older dogs and small breeds. Thus, a scientific investigation was performed in order to evaluate the clinical use of the medicines furosemide and enalapril maleate in dogs with this disease in CHF functional class Ib before and after the treatment was established. For this purpose 16 dogs with the given valve disease were used, separated into two groups: the first received furosemide (n=8 and the second received enalapril maleate (n=8 throughout 56 days. The dogs were evaluated in four stages (T0, T14, T28 and T56 day in relation to clinical signs, hematological, biochemical and serum assessment, which included serum angiotensin converting enzyme (ACE and aldosterone, as well as radiography, electrocardiography, Doppler-echocardiography and blood pressure. The results regarding the clinical, hematological and serum chemistry evaluations revealed no significant changes in both groups, but significant reductions in the values of ACE and aldosterone in the group receiving enalapril maleate were verified. The radiographic examination revealed reductions of VHS values and variable Pms wave of the electrocardiogram in both groups, but no changes in blood pressure values were identified. The echocardiogram showed a significant decrease of the variables LVDd/s in the studied groups and the FS% in animals that received only enalapril. Therefore, analysis of results showed that monotherapy based on enalapril maleate showed better efficiency of symptoms control in patients with CHF functional class Ib.
Effect of spacer grids on CHF in tube bundles
International Nuclear Information System (INIS)
Jayanti, Sreenivas; Valette, Michel
2004-01-01
Spacers grids are used to support tube bundles in steam generators and in nuclear reactor fuel assemblies. These grids interface with the flow and heat transfer in a number of ways and their effect has been studied by a number of researchers. It is known that generally they have a beneficial effect on critical heat flux (CHF) in typical nuclear reactor assemblies. However, the enhancement obtained depends on the geometric characteristics of the spacer grids as well as on the parameter range in terms of pressure, local mass velocity and quality. In the present study, the problem is approached in the context of a one-dimensional three-field model. Unlike in previous approaches, no specific modeling of the constitutive laws is made to account for spacer effects and only the geometric details such as the reduction in the cross-sectional area and the hydraulic diameter are included in the calculation which is otherwise the same as that for flow through a single tube. It is shown by comparison with literature data that this approach leads to satisfactory prediction of the thermal-hydraulic effects of spacers and that the beneficial effects of spacers on dry out can be manifested only when the entrainment rate is neither too high nor too low. Their effect on reducing the post-dry out wall temperature is also limited to certain cases. The present work has been performed as part of the EDF-CEA Neptune project also supported by the Institut de Radioprotection et de Surete Nucleaire (IRSN, France) and FRAMATOME-ANP. NEPTUNE is a new set of two phase thermalhydraulic computer codes devoted to safety analysis of nuclear power plants. (author)
THE STORY OF CHF OR HOW TO LOSE YOUR SLEEP AND MONEY BY IGNORING THE FOREIGN CURRENCY RISK
Directory of Open Access Journals (Sweden)
Laurentiu-Mihai Treapat
2015-05-01
Full Text Available This paper represents an empiric research how The Central Bank of Switzerland gave up on sustaining the minimum exchange rate for CHF, as a result of a dramatic movement in the history of the FX market. The decision has equally affected companies or families that got loans (usually in another currency than their incomes. Due to the troubles that reached social dimensions in some ECE countries, we decided that it is worth making an academic X-ray upon the way the specialists succeeded in transmitting their experiences to the others. The lessons from history should be learnt, it is the scientists’ duty to use their ability to get into the essence of the phenomena and to reveal the conclusions to the ones around.
Olah, George A; Prakash, G K Surya; Rasul, Golam
2016-01-05
The rearrangement pathways of the equilibrating tertiary carbocations, 2,3-dimethyl-2-butyl cation (C6H13(+), 1), 2,3,3-trimethyl-2-butyl cation (C7H15(+), 5) and 2,3-dimethyl-2-pentyl cation (C7H15(+), 8 and 9) were investigated using the ab initio/GIAO-CCSD(T) (13)C NMR method. Comparing the calculated and experimental (13)C NMR chemical shifts of a series of carbocations indicates that excellent prediction of δ(13)C could be achieved through scaling. In the case of symmetrical equilibrating cations (1 and 5) the Wagner-Meerwein 1,2-hydride and 1,2-methide shifts, respectively, produce the same structure. This indicates that the overall (13)C NMR chemical shifts are conserved and independent of temperature. However, in the case of unsymmetrical equilibrating cations (8 and 9) the Wagner-Meerwein shift produces different tertiary structures, which have slightly different thermodynamic stabilities and, thus, different spectra. At the MP4(SDTQ)/cc-pVTZ//MP2/cc-pVTZ + ZPE level structure 8 is only 90 calories/mol more stable than structure 9. Based on computed (13)C NMR chemical shift calculations, mole fractions of these isomers were determined by assuming the observed chemical shifts are due to the weighted average of the chemical shifts of the static ions. © 2015 Wiley Periodicals, Inc.
Energy Technology Data Exchange (ETDEWEB)
Czop, V; Herer, C; Souyri, A; Garnier, J
1993-09-01
In order to progress on the comprehensive modelling of the boiling crisis phenomenon, Electricite de France (EDF), Commissariat a l`Energie Atomique (CEA) and FRAMATOME have set up experimental programs involving in-R12 tests: the EDF APHRODITE program and the CEA-EDF-FRAMATOME DEBORA program. The first phase in these programs aims to acquire critical heat flux (CHF) data banks, within large thermal-hydraulic parameter ranges, both in cylindrical and annular configurations, and with different hydraulic diameters and heating lengths. Actually, three data banks have been considered in the analysis, all of them concerning in-R12 round tube tests: - the APHRODITE data bank, obtained at EDF with a 13 mn inside diameter, - the DEBORA data bank, obtained at CEA with a 19.2 mm inside diameter, - the KRISTA data bank, obtained at KfK with a 8 mm inside diameter. The analysis was conducted using CHF correlations and with the help of an advanced mathematical tool using pseudo-cubic thin plate type Spline functions. Two conclusions were drawn: -no influence of the heating length on our CHF results, - the influence of the diameter on the CHF cannot be simply expressed by an exponential function of this parameter, as thermal-hydraulic parameters also have an influence. Some calculations with Weisman and Pei theoretical boiling crisis model have been compared to experimental values: fairly good agreement was obtained, but further study must focus on improving the modelling of the influence of pressure and mass velocity. (authors). 12 figs., 4 tabs., 21 refs.
The Aphrodite boiling crisis program. Analysis of CHF tests performed on a vertical tube
International Nuclear Information System (INIS)
Souyri, A.; Conan, S.; Portesse, A.; Tremblay, D.
1992-09-01
In order to develop a comprehensive modelling of the boiling crisis phenomenon, the APHRODITE experimental program has been set up at ELECTRICITE DE FRANCE. Aiming at a better mechanistic understanding of this phenomenon, this program will investigate the influence of the experimental conditions (among which the mockup geometry and the boundary conditions) and the two-phase flow patterns via void fraction distributions. It has involved the construction of a R12 test loop, which can deliver a large thermal-hydraulic parameter ranges, and the development of a gamma-ray tomograph. The first experiments have been carried out on a vertical Inconel tube, 6 meters long with a bore diameter of 13 mm and a thickness of 0.5 mm. This electrically heated test section is heavily instrumented with 168 thermocouples welded along the tube, on its outer surface. After a refined calibration of the experimental procedure, a critical heat flux data bank has been collected within large pressure, mass velocity and critical steam quality ranges. These results are firstly compared with other CHF data obtained in similar conditions. Then several empirical correlations and a theoretical model for similar prediction in tubes are tested against these data
International Nuclear Information System (INIS)
Unal, C.; Nelson, R.
1991-01-01
After completing the thermal-hydraulic model developed in a companion paper, we performed assessment calculations of the model using steady-state and transient post-critical heat flux (CHF) data. This paper discusses the results of those calculations. The hot-patch model, in conjunction with the other thermal-hydraulic models, was capable of modeling the Winfrith post-CHF hot-patch experiments. The hot-patch model kept the wall temperatures at the specified levels in the hot-patch regions and did not allow any quench-front propagation from either the bottom or the top of the test section. Among the four Winfrith runs selected to assess the hot-patch model, the average deviation in hot-patch power predictions was 15.4%, indicating reasonable predictions of the amount of energy transferred to the fluid by the hot patch. The interfacial heat-transfer model tended to slightly under-predict the vapor temperatures. The maximum difference between calculated and measured vapor superheats was 20%, with a 10% difference for the remainder of the runs considered. The wall-to-fluid heat transfer was predicted reasonably well, and the predicted wall superheats were in reasonable agreement with measured data with a maximum relative error of less than 13%. The effects of pressure, test section power, and flow rate on the axial variation of tube wall temperature are predicted reasonably well for a large range of operating parameters. A comparison of the predicted and measured local wall. The thermal-hydraulic model in TRAC/PF1-MOD2 was used to predict the axial variation of void fraction as measured in Winfrith post-CHF tests. The predictions for reflood calculations were reasonable. The model correctly predicted the trends in void fraction as a result of the effect of pressure and power, with the effect of pressure being more apparent than that of power. 13 refs
Prinn, Ronald G.
2015-01-01
High frequency, in situ observations from 11 globally distributed sites for the period 1994–2014 and archived air measurements dating from 1978 onward have been used to determine the global growth rate of 1,1-difluoroethane (HFC-152a, CH[subscript 3]CHF[subscript 2]). These observations have been combined with a range of atmospheric transport models to derive global emission estimates in a top-down approach. HFC-152a is a greenhouse gas with a short atmospheric lifetime of about 1.5 years. Si...
Analysis of relations for heat transfer at the post-CHF regime
Energy Technology Data Exchange (ETDEWEB)
Dorokhovich, S. L. [Obninsk State Techical Univ., Obninsk (Russian Federation); Kirillov, P. L. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)
2003-07-01
Information about heat transfer rates in two-fluid flow at the post-CHF regime is important for analysis of accidents of water-cooled nuclear reactors as well as calculations of steam generators (liquid metal-water). It is complicate to create analytical methods because there is a variety of two-fluid flow regimes dictated by channel size, pressure, mass flow rate, heat flux, droplet spectrum, flow quality, other factors and, finally, by crisis type. At crisis in subcooled liquid or low quality two-phase flows Inverted Annular Film Boiling (IAFB) takes place when liquid flow is separated from the wall by a thin superheated vapor film. For dispersed flow crisis is usually related to drying a liquid film moving along the heated surface (wall). In both cases two-phase flow is thermodynamically nonequilibrium since the temperatures of phases (liquid and vapor) are different. The mean (at the rate of heat content) flow temperature is not the determining parameter. Different boundary conditions of experiment s uniform heat fluxes or 'hot' spots, are able to lead to different relations for the heat transfer coefficient. Last years the great number of semiempirical models were elaborated, that become more and more complicate. It is difficult to examine many parameters of the models. An agreement between final results and separate experimental data is not yet the evidence for the verity of extension while prerequisites taken in the models are often doubtful and hardly examined. Thus the correlations obtained from experimental data, for example, are used in practice. The analysis of relations for heat transfer at the Deteriorated Heat Transfer (DHT) regime, the comparison of relations with the data of look up tables made on the basis of the Institute of Physics and Power Engineering and Chalk River Laboratories experimental data banks are the objective of current report.
Analysis of relations for heat transfer at the post-CHF regime
International Nuclear Information System (INIS)
Dorokhovich, S. L.; Kirillov, P. L.
2003-01-01
Information about heat transfer rates in two-fluid flow at the post-CHF regime is important for analysis of accidents of water-cooled nuclear reactors as well as calculations of steam generators (liquid metal-water). It is complicate to create analytical methods because there is a variety of two-fluid flow regimes dictated by channel size, pressure, mass flow rate, heat flux, droplet spectrum, flow quality, other factors and, finally, by crisis type. At crisis in subcooled liquid or low quality two-phase flows Inverted Annular Film Boiling (IAFB) takes place when liquid flow is separated from the wall by a thin superheated vapor film. For dispersed flow crisis is usually related to drying a liquid film moving along the heated surface (wall). In both cases two-phase flow is thermodynamically nonequilibrium since the temperatures of phases (liquid and vapor) are different. The mean (at the rate of heat content) flow temperature is not the determining parameter. Different boundary conditions of experiment s uniform heat fluxes or 'hot' spots, are able to lead to different relations for the heat transfer coefficient. Last years the great number of semiempirical models were elaborated, that become more and more complicate. It is difficult to examine many parameters of the models. An agreement between final results and separate experimental data is not yet the evidence for the verity of extension while prerequisites taken in the models are often doubtful and hardly examined. Thus the correlations obtained from experimental data, for example, are used in practice. The analysis of relations for heat transfer at the Deteriorated Heat Transfer (DHT) regime, the comparison of relations with the data of look up tables made on the basis of the Institute of Physics and Power Engineering and Chalk River Laboratories experimental data banks are the objective of current report
International Nuclear Information System (INIS)
Johannsen, K.; Meinen, W.
1984-01-01
An experimental investigation of low-void heat transfer of water has been performed in the range of CHF and the minimum stable film boiling temperature. The heat transfer system used consists of a vertically mounted copper tube of 1 cm I.D. and 5 cm length with surface-temperature controlled, indirect Joule heating. Results are presented for upflowing water at inverted annular flow conditions in the inlet subcooling range of 2.5 - 40 0 C and mass flux range of 137-600 kg/m 2 s in terms of boiling curves and heat transfer coefficients versus wall temperature. Heat transfer in the stationary rewetting front, which occurs within the test section during operation in the transition boiling mode, is also dealt with. At high mass flux, occurrence of an inverse rewetting front has been observed. It is also noted that, at fixed location, minimum heat flux observed is usually not associated with the minimum stable film boiling temperature
Energy Technology Data Exchange (ETDEWEB)
Metzler, Dominik; Oehrlein, Gottlieb S., E-mail: oehrlein@umd.edu [Department of Materials Science and Engineering, and Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, Maryland 20740 (United States); Li, Chen [Department of Physics, and Institute for Research in Electronics and Applied Physics, University of Maryland, College Park, Maryland 20740 (United States); Engelmann, Sebastian; Bruce, Robert L.; Joseph, Eric A. [IBM T. J. Watson Research Center, Yorktown Heights, New York 10598 (United States)
2016-01-15
The need for atomic layer etching (ALE) is steadily increasing as smaller critical dimensions and pitches are required in device patterning. A flux-control based cyclic Ar/C{sub 4}F{sub 8} ALE based on steady-state Ar plasma in conjunction with periodic, precise C{sub 4}F{sub 8} injection and synchronized plasma-based low energy Ar{sup +} ion bombardment has been established for SiO{sub 2} [Metzler et al., J. Vac. Sci. Technol. A 32, 020603 (2014)]. In this work, the cyclic process is further characterized and extended to ALE of silicon under similar process conditions. The use of CHF{sub 3} as a precursor is examined and compared to C{sub 4}F{sub 8}. CHF{sub 3} is shown to enable selective SiO{sub 2}/Si etching using a fluorocarbon (FC) film build up. Other critical process parameters investigated are the FC film thickness deposited per cycle, the ion energy, and the etch step length. Etching behavior and mechanisms are studied using in situ real time ellipsometry and x-ray photoelectron spectroscopy. Silicon ALE shows less self-limitation than silicon oxide due to higher physical sputtering rates for the maximum ion energies used in this work, ranged from 20 to 30 eV. The surface chemistry is found to contain fluorinated silicon oxide during the etching of silicon. Plasma parameters during ALE are studied using a Langmuir probe and establish the impact of precursor addition on plasma properties.
Napovedovanje prodaje izolacijskega stekla v podjetju Reflex Gornja Radgona d.o.o.
Kebler, Andreja
2015-01-01
V projektni nalogi je predstavljeno napovedovanje prodaje v podjetjih, kvantitativne metode za napovedovanje ter kazalci za preveritev točnosti napovedi. Glavni cilj te projektne naloge je bil napovedati prihodke od prodaje ter količino izdelanega izolacijskega stekla v podjetju Reflex Gornja Radgona d.o.o. z naslednjimi kvantitativnimi metodami napovedovanja: metoda drsečih aritmetičnih sredin, tehtana aritmetična sredina, metoda eksponentnega izravnavanja, metoda izboljšanega eksponentne...
A preliminary study on the etching behavior of SiO sub 2 aerogel film with CHF sub 3 gas
Wang, S J; Yeom, G Y
1998-01-01
Etching behavior of SiO sub 2 aerogel film has been investigated in order to examine the feasibility of its application to an interlevel dielectric material. Low dielectric property of SiO sub 2 aerogel film is simply originated from its highly porous structure, but interconnected particles are covered with surface chemical bondings (-OH, -OC sub 2 H sub 5 , etc). Etching experiments have been performed with high density inductively coupled CHF sub 3 plasma. The effects of porous structure and surface chemical bondings on the etching of SiO sub 2 aerogel film have been analyzed. The changes of surface morphology were observed using scanning electron microscopy. X-ray photoelectron spectroscopic analyses revealed compositions and chemical bonding states of reaction layer. From the analyses, 3-dimensional etching was not feasible macroscopically in SiO sub 2 aerogel film even with its porous nature because network structure was maintained through the etching process. Internal surface chemicals seemed to act an ...
Directory of Open Access Journals (Sweden)
D. Hindle
2012-09-01
Full Text Available Sebagian besar daripada keputusan-keputusan yang penting dalam bidang pelayanan kesehatan harus didasarkan kepada pendapat individu yang subyektif, oleh karena data-data yang tepat dan model-model analitis tidak cukup tersedia. Metoda Delphi dapat digunakan maka data-data subyektif dapat dikumpulkan dan dianalisa secara sistematis, walaupun metoda tersebut sangat murah digunakan dan mudah dimengerti. Satu contoh daripada penggunaan metoda Delphi diberikan dalam naskah ini, mengenai persiapan-persiapan Pelita 3 Kesehatan di Kalimantan Tengah.
Konstam, Varda; Gregory, Douglas; Chen, Jie; Weintraub, Andrew; Patel, Ayan; Levine, Daniel; Venesy, David; Perry, Kathleen; Delano, Christine; Konstam, Marvin A
2011-02-01
Although disease management programs have been shown to provide a number of clinical benefits to patients with heart failure (HF), the incremental impact of an automated home monitoring (AHM) system on health-related quality of life (HRQL) is unknown. We performed a prospective randomized investigation, examining the additive value of AHM to a previously described nurse-directed HF disease management program (SPAN-CHF), with attention to HRQL, in patients with a recent history of decompensated HF. A total of 188 patients were randomized to receive the SPAN-CHF intervention for 90 days, either with (AHM group) or without (NAHM, standard-care group) AHM, with a 1:1 randomization ratio after HF-related hospitalization. HRQL, measured by the Minnesota Living With Heart Failure Questionnaire (MLHFQ) (Physical, Emotional, and Total scores on MLHFQ) was assessed at 3 time points: baseline, 45 days, and 90 days. Although both treatments (AHM and NAHM) improved HRQL at 45 and 90 days compared with baseline with respect to Physical, Emotional, and Total domain scales, no significant difference emerged between AHM and NAHM groups. AHM and NAHM treatments demonstrated improved HRQL scores at 45 and 90 days after baseline assessment. When comparing 2 state-of the-art disease management programs regarding HRQL outcomes, our results did not support the added value of AHM. Copyright © 2011. Published by Elsevier Inc.
Energy Technology Data Exchange (ETDEWEB)
Steyn, J [National Physical Research Laboratory, Pretoria (South Africa)
1960-06-15
The accuracy of the 4 {pi} liquid scintillation counting method of standardizing {beta} emitters was compared to 4 l{pi} {beta}-{gamma} coincidence counting for the nuclides Co{sup 60}, I{sup 131} and Au{sup 198}. For P{sup 32} the liquid counting results were compared to 4 {pi} proportional counting. The efficiency of the liquid scintillation counting method was found to be energy dependent, dropping to about 97.5% for Co{sup 60} which was the lowest energy {beta} emitter investigated. (author) [French] La precision de la methode de comptage 4 {pi} a scintillateurs liquides pour l'etalonnage des emetteurs {beta} a ete comparee au comptage par coincidences 4 {pi} {beta}-{gamma} pour le So{sup 60}, le I{sup 131} et le Au{sup 198}. Dans le cas du P{sup 32}, les resultats du comptage au liquide ont ete compares a ceux du comptage 4 {pi} proportionnel. On a constate que le rendement de la methode de comptage a scintillateurs liquides variait en fonction de l'energie emise et qu'il descendait a environ 97.5% pour le Co{sup 60} qui, de tous les emetteurs {beta} etudies, emet l'energie la plus faible. (author) [Spanish] El autor compara la precision del metodo de recuento con centelleador iquido 4 {pi} para normalizar emisores {beta} con la del metodo de coincidencias {beta}-{gamma} 4 {pi}, para los siguientes nuclidos: So{sup 60}, I{sup 131} y Au{sup 198}. En el caso del P{sup 32}, confronta los resultados del primer metodo con los obtenidos mediante el recuento proporcional 4 {pi}. Comprueba que la eficacia del metodo de recuento con centelleador liquido depende de la energia y desciende al 97.5%, aproximadamente, para el Co{sup 60}, que fue el emisor {beta} mas debil que se investigo. (author) [Russian] Tochnost' 4 {pi} zhidkogo stsintillyatsionnog o metoda podscheta standartiziruemogo {beta}-izluchatelya sravnivalas' s 4 {pi} {beta}-{gamma} metodom podscheta na sovpadeniyakh dlya izotopov So{sup 60}, I{sup 131} i Au{sup 198}. Dlya R{sup 32} rezultaty zhidkogo
Local Heat Transfer and CHF for Subcooled Flow Boiling - Annual Report 1993
International Nuclear Information System (INIS)
Boyd, Ronald D.
2000-01-01
Subcooled flow boiling in heated coolant channels is an important heat transfer enhancement technique in the development of fusion reactor components, where high heat fluxes must be accommodated. As energy fluxes increase in magnitude, additional emphasis must be devoted to enhancing techniques such as sub cooling and enhanced surfaces. In addition to subcooling, other high heat flux alternatives such as high velocity helium and liquid metal cooling have been considered as serious contenders. Each technique has its advantages and disadvantages [1], which must be weighed as to reliability and reduced cost of fusion reactor components. Previous studies [2] have set the stage for the present work, which will concentrate on fundamental thermal hydraulic issues associated with the h-international Thermonuclear Experimental Reactor (ITER) and the Engineering Design Activity (EDA). This proposed work is intended to increase our understanding of high heat flux removal alternatives as well as our present capabilities by: (1) including single-side heating effects in models for local predictions of heat transfer and critical heat flux; (2) inspection of the US, Japanese, and other possible data sources for single-side heating, with the aim of exploring possible correlations for both CHF and local heat transfer; and (3) assessing the viability of various high heat flux removal techniques. The latter task includes: (a) sub-cooled water flow boiling with enhancements such as twisted tapes, and hypervapotrons, (b) high velocity helium cooling, and (c) other potential techniques such as liquid metal cooling. This assessment will increase our understanding of: (1) hypervapotron heat transfer via fins, flow recirculation, and flow oscillation, and (2) swirl flow. This progress report contains selective examples of ongoing work. Section II contains an extended abstract, which is part of and evolving technical paper on single-side f heating. Section III describes additional details
Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory
International Nuclear Information System (INIS)
Zuniga-Gutierrez, Bernardo; Camacho-Gonzalez, Monica; Bendana-Castillo, Alfonso; Simon-Bastida, Patricia; Calaminici, Patrizia; Köster, Andreas M.
2015-01-01
The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H 12 C– 12 CH–DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated
Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory
Energy Technology Data Exchange (ETDEWEB)
Zuniga-Gutierrez, Bernardo, E-mail: bzuniga.51@gmail.com [Departamento de Ciencias Computacionales, Universidad de Guadalajara, Blvd. Marcelino García Barragán 1421, C.P. 44430 Guadalajara, Jalisco (Mexico); Camacho-Gonzalez, Monica [Universidad Tecnológica de Tecámac, División A2, Procesos Industriales, Carretera Federal México Pachuca Km 37.5, Col. Sierra Hermosa, C.P. 55740 Tecámac, Estado de México (Mexico); Bendana-Castillo, Alfonso [Universidad Tecnológica de Tecámac, División A3, Tecnologías de la Información y Comunicaciones, Carretera Federal México Pachuca Km 37.5, Col. Sierra Hermosa, C.P. 55740 Tecámac, Estado de México (Mexico); Simon-Bastida, Patricia [Universidad Tecnlógica de Tulancingo, División Electromecánica, Camino a Ahuehuetitla No. 301, Col. Las Presas, C.P. 43642 Tulancingo, Hidalgo (Mexico); Calaminici, Patrizia; Köster, Andreas M. [Departamento de Química, CINVESTAV, Avenida Instituto Politécnico Nacional 2508, A.P. 14-740, México D.F. 07000 (Mexico)
2015-09-14
The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H{sup 12}C–{sup 12}CH–DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated.
Efficient calculation of nuclear spin-rotation constants from auxiliary density functional theory.
Zuniga-Gutierrez, Bernardo; Camacho-Gonzalez, Monica; Bendana-Castillo, Alfonso; Simon-Bastida, Patricia; Calaminici, Patrizia; Köster, Andreas M
2015-09-14
The computation of the spin-rotation tensor within the framework of auxiliary density functional theory (ADFT) in combination with the gauge including atomic orbital (GIAO) scheme, to treat the gauge origin problem, is presented. For the spin-rotation tensor, the calculation of the magnetic shielding tensor represents the most demanding computational task. Employing the ADFT-GIAO methodology, the central processing unit time for the magnetic shielding tensor calculation can be dramatically reduced. In this work, the quality of spin-rotation constants obtained with the ADFT-GIAO methodology is compared with available experimental data as well as with other theoretical results at the Hartree-Fock and coupled-cluster level of theory. It is found that the agreement between the ADFT-GIAO results and the experiment is good and very similar to the ones obtained by the coupled-cluster single-doubles-perturbative triples-GIAO methodology. With the improved computational performance achieved, the computation of the spin-rotation tensors of large systems or along Born-Oppenheimer molecular dynamics trajectories becomes feasible in reasonable times. Three models of carbon fullerenes containing hundreds of atoms and thousands of basis functions are used for benchmarking the performance. Furthermore, a theoretical study of temperature effects on the structure and spin-rotation tensor of the H(12)C-(12)CH-DF complex is presented. Here, the temperature dependency of the spin-rotation tensor of the fluorine nucleus can be used to identify experimentally the so far unknown bent isomer of this complex. To the best of our knowledge this is the first time that temperature effects on the spin-rotation tensor are investigated.
Wymagania dotyczące przeglądów stanu technicznego budynków – studium przypadku
Directory of Open Access Journals (Sweden)
Krystyna Urbańska
2018-04-01
Full Text Available Celem artykułu jest zwrócenie uwagi na jakość wykonywanych w ostatnim czasie okresowych przeglądów stanu technicznego budynków oraz zasygnalizowanie zarządcom budynków potrzeby sprawdzania zawartości otrzymywanych opracowań. Zwłaszcza w przypadku znacznej ilości zleceń przyjmowanych w jednym terminie. Ocenę rzetelności sporządzanych okresowych przeglądów stanu technicznego przedstawiono na przykładzie budynku wielorodzinnego zlokalizowanego w Zielonej Górze.
Benchmarking quantum mechanical calculations with experimental NMR chemical shifts of 2-HADNT
Liu, Yuemin; Junk, Thomas; Liu, Yucheng; Tzeng, Nianfeng; Perkins, Richard
2015-04-01
In this study, both GIAO-DFT and GIAO-MP2 calculations of nuclear magnetic resonance (NMR) spectra were benchmarked with experimental chemical shifts. The experimental chemical shifts were determined experimentally for carbon-13 (C-13) of seven carbon atoms for the TNT degradation product 2-hydroxylamino-4,6-dinitrotoluene (2-HADNT). Quantum mechanics GIAO calculations were implemented using Becke-3-Lee-Yang-Parr (B3LYP) and other six hybrid DFT methods (Becke-1-Lee-Yang-Parr (B1LYP), Becke-half-and-half-Lee-Yang-Parr (BH and HLYP), Cohen-Handy-3-Lee-Yang-Parr (O3LYP), Coulomb-attenuating-B3LYP (CAM-B3LYP), modified-Perdew-Wang-91-Lee-Yang-Parr (mPW1LYP), and Xu-3-Lee-Yang-Parr (X3LYP)) which use the same correlation functional LYP. Calculation results showed that the GIAO-MP2 method gives the most accurate chemical shift values, and O3LYP method provides the best prediction of chemical shifts among the B3LYP and other five DFT methods. Three types of atomic partial charges, Mulliken (MK), electrostatic potential (ESP), and natural bond orbital (NBO), were also calculated using MP2/aug-cc-pVDZ method. A reasonable correlation was discovered between NBO partial charges and experimental chemical shifts of carbon-13 (C-13).
International Nuclear Information System (INIS)
Araya, Fumimasa; Nakatsuka, Toru; Yoritsune, Tsutomu
2002-10-01
In order to improve plutonium utilization, design studies of reduced moderation water reactors which have hard neutron energy spectrum have been carried out at Division of Energy System Research of Japan Atomic Energy Research Institute (JAERI). At present, triangle, tight pitch lattice cores with about 1 mm gap width between fuel rods have been focused in the neutronic core design. Since a degradation of the heat removal from the fuel rods is worried, an evaluation of heat removal capability i.e. critical heat flux becomes one of important evaluation items in the feasibility study. However, any of published data base, which can be applicable to the evaluation on such narrow gap width cores, does not exist. Therefore, in the present study, in order to accumulate applicable data and to confirm applicability of an evaluation methodology of critical heat flux, basic experiments on the critical heat flux were performed using the test sections consisted of 7 heater rods bundles with the gap widths of 1.5, 1.0 and 0.6 mm under the PWR pressure conditions. The present report describes the experimental apparatus, experimental conditions and accumulated data. Analysis results of the data and the applicability of the evaluation methodology used for the design work are also discussed in this report. As the results of the experiment, it was found that the critical heat flux increased as the mass flux and the inlet subcooling increased. In the region of the mass flux less than about 2,000 kg/m 2 /s, the critical heat flux decreased as the gap width decreased. In the larger mass flux region, obvious trend of effects of the gap width on critical heat flux were not observed due to data scatterings. The flow-area-averaged thermal-equilibrium quality at the CHF position was in the higher ranges from 0.3 to 0.8 in the cases of gap widths of 1.0 and 0.6 mm, and 0.1 to 0.3 in the 1.5 mm case. Based on the experimental results such that the CHFs occurred in the higher quality range and
Powerful Swirl Generation of Flow-driven Rotating Mixing Vane for Enhancing CHF
International Nuclear Information System (INIS)
Seo, Han; Seo, Seok Bin; Heo, Hyo; Bang, In Cheol
2014-01-01
Mixing vanes are utilized to improve CHF and heat transfer performance in the rod bundle during normal operation. Experimental measurement of the swirling flow from a split vane pair was conducted using particle image velocimetry (PIV) and boroscope. The lateral velocity fields show that the swirling flow was initially centered in the subchannel and the computational fluid dynamics (CFD) analysis was performed based on the experiment. To visualize flow patterns in the 5Χ5 subchannel using PIV, matching the refraction between the working fluid and the structure was considered and the experiment aimed to develop the experimental data for providing fundamental information of the CFD analysis. The fixed split vane is the main mixing inducer in the fuel assembly. In a heat exchanger research, propeller type swirl generates at several pitch ratios and different blades angles were used to enhance heat transfer rate. Significant improvements of the heat transfer rate using the propellers were confirmed due to creation of tangential flow. In the present study, the mixing effect of rotation vane which has a shape of propeller was studied using PIV. A split vane was considered in the experiment to show the effect of rotation vane. Vertical and horizontal flow analyses were conducted to show the possible use of rotation vane in a subchannel. In the present work, the study of flow visualization using three types of vanes is conducted to show the mixing effect. The vertical flow and the horizontal flow distributions were analyzed in the two experimental facilities. For the vertical flow facility, flow distributions, flow profiles, and the turbulence kinetic energy are analyzed at the centerline of the channel. The results show that the rotation vane has the highest flow and turbulence kinetic intensity at the centerline of the channel. For the horizontal flow facility, the results indicate that lateral flow of the rotation vane is generated and maintained along with the flow
Directory of Open Access Journals (Sweden)
Jiránková Eva
2012-09-01
Full Text Available Metoda hodnocení porušování pevného nadloží exploatovaných slojí je založena na současném hodnocení poklesů povrchu a seismické aktivity vzhledem k časoprostorovému postupu dobývání v závislosti na charakteru horského masivu a předchozí hornické činnosti. Pokud nedojde k prolomení pevných nadložních vrstev, je okolí vydobytého prostoru značně přitíženo a podstatně se zvyšuje nebezpečí vzniku anomálních geomechanických jevů. V článku je vysvětlen mechanismus porušování pevných nadložních vrstev v konkrétních podmínkách.
Papež, Jan
2008-01-01
This thesis describes the criss-cross method, which solves the tasks of linear programming and does not need primar or dual feasibility of the basis. At first, the single-phase simplex method, that needs primal feasibility, gets described. After that, we describe the dual simplex method, which needs dual feasibility. The criss-cross method combines both of these methods. All of mentioned methods are explained and demonstrated in several examples.
WHATSAPP FORENSICS PADA ANDROID SMARTPHONE : A SURVEY
Directory of Open Access Journals (Sweden)
Zulkarnaen Akbar
2016-12-01
Full Text Available Salah satu applikasi jejaring sosial yang sangat populer saat ini adalah WhatsApp. Hampir seluruh pengguna smartphone menggunakan applikasi ini sebagai media komunikasi. Berbagai macam perkembangan atau fitur baru telah banyak ditambahkan pengembang sebagai fasilitas yang dapat memanjakan para pengguna. Peranan sistem keamanan tentunya sangat penting untuk menunjang keamanan privasi para pengguna agar kerahasiaan tetap terjaga. Beberapa peneliti telah banyak melakukan experimen mobile forensics untuk mendapatkan berbagai informasi dari para pengguna WhatsApp. Pada paper ini membahas survey berbagai metoda dari berbagai para peneliti WhatsApp forensics. Dalam sebuah proses mobile metoda yang digunakan dalam proses forensics antara lain menggunakan internet protocol dan live memory. Untuk proses mobile forensics khususnya pada applikasi WhatsApp dapat dilakukan dengan menggunakan metoda tersebut untuk memperoleh data informasi yang dibutuhkan.
Energy Technology Data Exchange (ETDEWEB)
Chang, Soon Heung; Baek, Won Pil; Yang, Soo Hyung; No, Chang Hyun [Korea Advanced Institute of Science and Technology, Taejon (Korea)
2000-04-01
To acquire CHF data through the experiments and develop prediction models, research was conducted. Final objectives of research are as follows: 1) Production of tube CHF data for low and middle pressure and mass flux and Flow Boiling Visualization. 2) Modification and suggestion of tube CHF prediction models. 3) Development of fuel bundle CHF prediction methodology base on tube CHF prediction models. The major results of research are as follows: 1) Production of the CHF data for low and middle pressure and mass flux. - Acquisition of CHF data (764) for low and middle pressure and flow conditions - Analysis of CHF trends based on the CHF data - Assessment of existing CHF prediction methods with the CHF data 2) Modification and suggestion of tube CHF prediction models. - Development of a unified CHF model applicable for a wide parametric range - Development of a threshold length correlation - Improvement of CHF look-up table using the threshold length correlation 3) Development of fuel bundle CHF prediction methodology base on tube CHF prediction models. - Development of bundle CHF prediction methodology using correction factor. 11 refs., 134 figs., 25 tabs. (Author)
International Nuclear Information System (INIS)
Niceno, B.; Sato, Y.; Badillo, A.; Andreani, M.
2010-01-01
In this paper we describe current activities on the project Multi-Scale Modeling and Analysis of convective boiling (MSMA), conducted jointly by the Paul Scherrer Institute (PSI) and the Swiss Nuclear Utilities (Swissnuclear). The long-term aim of the MSMA project is to formulate improved closure laws for Computational Fluid Dynamics (CFD) simulations for prediction of convective boiling and eventually of the Critical Heat Flux (CHF). As boiling is controlled by the competition of numerous phenomena at various length and time scales, a multi-scale approach is employed to tackle the problem at different scales. In the MSMA project, the scales on which we focus range from the CFD scale (macro-scale), bubble size scale (meso-scale), liquid micro-layer and triple interline scale (micro-scale), and molecular scale (nano-scale). The current focus of the project is on micro- and meso- scales modeling. The numerical framework comprises a highly efficient, parallel DNS solver, the PSI-BOIL code. The code has incorporated an Immersed Boundary Method (IBM) to tackle complex geometries. For simulation of meso-scales (bubbles), we use the Constrained Interpolation Profile method: Conservative Semi-Lagrangian 2nd order (CIP-CSL2). The phase change is described either by applying conventional jump conditions at the interface, or by using the Phase Field (PF) approach. In this work, we present selected results for flows in complex geometry using the IBM, selected bubbly flow simulations using the CIP-CSL2 method and results for phase change using the PF approach. In the subsequent stage of the project, the importance of effects of nano-scale processes on the global boiling heat transfer will be evaluated. To validate the models, more experimental information will be needed in the future, so it is expected that the MSMA project will become the seed for a long-term, combined theoretical and experimental program
Staff Association
2013-01-01
Do not hesitate to benefit of our offers in our partners: Théâtre de Carouge Discount of 5 CHF for all shows (30 CHF instead of 35 CHF) and on season tickets « first performance » ( 132 CHF instead 162 CHF) and also on « classical » ( 150 CHF instead of 180 CHF) upon presentation of your Staff Association membership card before payment. Théâtre La Comédie de Genève 20% off on tickets (full price – also available for partner): from 24 to 32 CHF a ticket instead of 30 to 40 CHF depending on the shows. 40% off on annual subscriptions (access to the best seats, pick up tickets at the last minute): 200 CHF for 9 shows (about 22 CHF a ticket instead of 30 to 40 CHF. Discounted card: 60 CHF and single price ticket of 16 CHF.
Special discount to the members of the Staff Association
Association du personnel
2012-01-01
FNAC 5% discount on gifts card available in four Swiss shops without any restriction. Gifts card on sale to the Staff Association Secretariat. TPG 50 CHF discount on annual subscriptions. Subscription « tout Genève » for adult: 650 CHF; for junior: 400 CHF. On sale to the Staff Association Secretariat. Théâtre de Carouge Discount of 5.-CHF for all shows (30.– CHF instead of 35.-CHF) and on season tickets « first performance » ( 132.– CHF instead 162.– CHF) and also on « classical » ( 150.– CHF instead of 180.– CHF) upon presentation of your Staff Association membership card before payment. Aquaparc Discounted prices on admission of whole day. Children from 5 to 15 years: 30.-CHF instead of 39.-CHF; Adults from 16 years: 36.-CHF instead of 49.-CHF. Tickets on sale to the Staff Association Secretariat. Go Sport 15% off on all purchases in the whole shop upon present...
Staff Association
2011-01-01
Adults: 31 CHF instead of 42 CHF Children: 25 CHF instead of 34 CHF Aquaparc Les Caraïbes sur Léman 1807 Le Bouveret (VS) Tickets are valid for both the inside and outside areas. Les billets sont valables pour les espaces intérieurs et extérieurs Adultes : 31 CHF au lieu de 42 CHF Enfants : 25 CHF au lieu de 34 CHF
Felker, G Michael; Mentz, Robert J; Adams, Kirkwood F; Cole, Robert T; Egnaczyk, Gregory F; Patel, Chetan B; Fiuzat, Mona; Gregory, Douglas; Wedge, Patricia; O'Connor, Christopher M; Udelson, James E; Konstam, Marvin A
2015-09-01
Congestion is a primary reason for hospitalization in patients with acute heart failure (AHF). Despite inpatient diuretics and vasodilators targeting decongestion, persistent congestion is present in many AHF patients at discharge and more severe congestion is associated with increased morbidity and mortality. Moreover, hospitalized AHF patients may have renal insufficiency, hyponatremia, or an inadequate response to traditional diuretic therapy despite dose escalation. Current alternative treatment strategies to relieve congestion, such as ultrafiltration, may also result in renal dysfunction to a greater extent than medical therapy in certain AHF populations. Truly novel approaches to volume management would be advantageous to improve dyspnea and clinical outcomes while minimizing the risks of worsening renal function and electrolyte abnormalities. One effective new strategy may be utilization of aquaretic vasopressin antagonists. A member of this class, the oral vasopressin-2 receptor antagonist tolvaptan, provides benefits related to decongestion and symptom relief in AHF patients. Tolvaptan may allow for less intensification of loop diuretic therapy and a lower incidence of worsening renal function during decongestion. In this article, we summarize evidence for decongestion benefits with tolvaptan in AHF and describe the design of the Targeting Acute Congestion With Tolvaptan in Congestive Heart Failure Study (TACTICS) and Study to Evaluate Challenging Responses to Therapy in Congestive Heart Failure (SECRET of CHF) trials. © 2015 American Heart Association, Inc.
Directory of Open Access Journals (Sweden)
Siniša Borović
2004-01-01
Full Text Available U poslednjoj fazi procesa javne nabavke komisija se susreće sa problemom izbora naboljeg ponuđača, odnosno onog čija ponuda u najvećoj meri ispunjava zahteve i uslove koji su navedeni u konkursnoj dokumentaciji. Mora se doneti odluka uz uvažavanje više različitih, a često i protivrečnih kriterijuma. Za rešavanje ovakvih i sličnih problema razvijen je čitav niz metoda koje pripadaju oblasti višekriterijumske analize i rangiranja. Uzimajući u obzir karakteristike problema izbora ponuđača u procesu javne nabavke, iz skupa navedenih metoda izdvojena je metoda analitičkih hijerarhijskih procesa (AHP, kao osnovna metoda za rangiranje ponuđača. Za eventualnu kontrolu izvršenog rangiranja predlaže se familija metoda PROMETHEE I-II. / In the last phase of a tender process, the Commission has a problem with choosing the best bidder, i.e. the one whose offer meets the highest requirements in the Tender documentation. A decision has to be made taking into account many different, and very often contradictory, criteria. For solving this one as well as similar problems, numerous methods, belonging to the multicriteria analysis and ranking, are developed. Taking in to account the characteristics of a problem imposed by choosing the bidder in a Tender process, one of the mentioned methods, the method of analytical hierarchy process (AHP has been chosen as a basic method for ranking bidders. For the performed ranking control, the PROMETHEE I-II, method family is proposed.
Directory of Open Access Journals (Sweden)
Wrana B.
2011-03-01
Full Text Available Artykuł podejmuje zagadnienie analizy rozchodzenia sie fal naprezeniowych w gruncie w ujeciu metody elementów skonczonych bazujac na sformułowaniu rozwiazania ciagłego w przestrzeni i nieciagłego w dziedzinie czasu Galerkina (space and time-discontinous Galerkin TDG finite element method. W tym sformułowaniu zarówno przemieszczenia jak i predkosci sa wielkosciami nieznanymi wzajemnie niezaleznymi aproksymowanymi ciagłymi funkcjami kształtu w przestrzeni i nieciagłymi funkcjami kształtu w czasie. Do opisu zachowania sie gruntu w pełni nasyconego woda zastosowano sformułowanie u-p w ujeciu metody elementów skonczonych. Grunt traktowany jest, jako osrodek dwufazowy składajacy sie ze szkieletu i wody w porach. Zastosowane sformułowanie uwzglednia tłumienie osrodka przez uwzglednienie dyssypacji energii proporcjonalnej do predkosci wody wzgledem szkieletu. W artykule przedstawiono porównanie proponowanej metody rozwiazania numerycznego w dziedzinie czasu do metod obecnie stosowanych, takich jak: metoda róznicy centralnej, metoda Houbolta, Wilsona θ, HHT-α oraz najczesciej stosowanej metody Newmarka. Z porównania wynika, ze proponowana metoda jest metoda stabilna o małym błedzie numerycznego rozwiazania.
Pilewska, Wiesława; Pilewski, Robert; Żukow, Walery
2013-01-01
Zdaniem teoretyków sportu budowa ciała sportowców różni się zdecydowanie od budowy osób nie zajmujących się sportem, co ma istotne znaczenie w działalności sportowej. W wielu dyscyplinach sportowych określona budowa ciała osobników predestynuje do podejmowania określonej aktywności ruchowej. Stwierdzono, iż specyfika budowy somatycznej zawodników uzależniona jest od charakteru wykonywanej pracy a z punktu widzenia biomechaniki związana jest z efektywnością wykonywanych ćwiczeń. W pracy pod...
Energy Technology Data Exchange (ETDEWEB)
Liu, Xinke; He, Jiazhu; Tang, Dan; Jia, Fang; Lu, Youming, E-mail: ymlu@szu.edu.cn; Zhu, Deliang; Liu, Wenjun; Cao, Peijiang; Han, Sun [College of Materials Science and Engineering, Shenzhen Engineering Laboratory for Advanced Technology of Ceramics, Nanshan District Key Lab for Biopolymer and Safety Evaluation, Shenzhen University, 3688 Nanhai Ave, Shenzhen 518060 (China); Liu, Qiang; Wen, Jiao; Yu, Wenjie, E-mail: casan@mail.sim.ac.cn [State Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, CAS,865 Chang Ning Road, Shanghai 200050 (China); Pan, Jisheng [Institute of Materials Research and Engineering, Agency for Science Technology and Research, Singapore 117602 (Singapore); He, Zhubing [Department of Materials Science and Engineering, South University of Science and Technology of China, 1088 Xueyuan Road, Shenzhen 518055 (China); Ang, Kah-Wee [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117583 (Singapore)
2015-09-07
The energy band alignment between HfO{sub 2}/multilayer (ML)-MoS{sub 2} was characterized using high-resolution x-ray photoelectron spectroscopy. The HfO{sub 2} was deposited using an atomic layer deposition tool, and ML-MoS{sub 2} was grown by chemical vapor deposition. A valence band offset (VBO) of 1.98 eV and a conduction band offset (CBO) of 2.72 eV were obtained for the HfO{sub 2}/ML-MoS{sub 2} interface without any treatment. With CHF{sub 3} plasma treatment, a VBO and a CBO across the HfO{sub 2}/ML-MoS{sub 2} interface were found to be 2.47 eV and 2.23 eV, respectively. The band alignment difference is believed to be dominated by the down-shift in the core level of Hf 4d and up-shift in the core level of Mo 3d, or the interface dipoles, which caused by the interfacial layer in rich of F.
STATE OF THE ART IN PROTEOMICS FOR CANCER DETECTION
Directory of Open Access Journals (Sweden)
Syafrizayanti Syafrizayanti
2014-12-01
Full Text Available The earliest stages of cancer detection determine the successful of cancer treatment andtherapy. The existing cancer test or detection methods have been routinely used, but they arelack of sensitivity and specificity that are needed to avoid false positive or negative results. Thegenomic basedtechniques have been applied, although molecular understandings of cancerfar from complete, but few genomic platforms are becoming routine. Application of proteomicsbasedtechniques provide intriguing outcome, which is cancer detection at their earliest stages.Proteomics have exposed a new perspective into the phases of tumorigenesis and depictedmore detailed molecular network scheme, which made important contributions in the discoveryof biomarker of early diagnosis, prognosis and prediction outcome of cancer therapies.The noticeable proteomic platforms to achieve these goals are protein microarray, tissuemicroarray, mass spectrometry-based proteomic, and two-dimensionalgel electrophoresis (2-DE. The application of these techniques will be overviewed, providing a general review ofcurrent proteomic methods in cancer detection and subsequently improvement in prognosisand prediction of cancer therapies.Keywords: proteomics, protein microarrays, mass spectrometry, cancer biomarkerAbstrakDeteksi dini kanker sangat menentukan keberhasilan penanganan dan terapi kanker. Hinggasaat ini, telah banyak jenis metoda deteksi dan uji kanker yang sudah rutin digunakan, akantetapi metoda-metoda tersebut memiliki tingkat sensitifitas dan spesifikasi yang rendah,sehingga sering menyebabkan terjadi kesalahan hasil uji baik secara positif ataupun negatif.Bidang genomik telah banyak digunakan untuk lebih memahami kanker pada level molekuler,meskipun hasil yang diperoleh belum mendalam, akan tetapi beberapa metoda berbasiskangenomik telah mulai rutin digunakan. Bidang pioteomik mulai banyak diaplikasikan untukkeperluan deteksi kankersedini mungkin. Proteomik memberikan perspektif
Energy Technology Data Exchange (ETDEWEB)
Maglic, R [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)
1962-11-15
Reactivity of a reactor depends on production, absorption and leaking of neutrons. Change of absorption causes reactivity change, and this fact is used for determining the neutron absorption cross section for the sample inserted in the reactor core. Method for determining the absorption cross section based on reactivity change is called method of safety coefficient. Measurements of neutron absorption cross section for graphite was done in the RA reactor vertical experimental channel VK-5. taking into account the results obtained for five types of graphite this method is considered to be reliable for use. Comparison of nuclear properties of different types of graphite was done as well. Reaktivnost reaktora zavisi od proizvodnje neutrona, apsorpcije i isticanja neutrona. Promena apsorpcije izaziva promene reaktivnosti reaktora pa se ova osobina koristi za odedjivanje neutronskog apsorpcionog preseka uzorka koji se unosi u reaktor. Metoda merenja apsorpcionog preseka na bazi promene reaktivnosti nazvana je metodom koeficijenta opasnosti. Merenje apsorpcionog preseka grafita uradjeno je na reaktoru RA u vertikalnom eksperimentalnom kanalu VK-5. S obzirom na rezultate koji su dobijeni za pet vrsta grafita moze se smatrati da je opravdano koriscenje ove metode. Izvrseno je i poredjenje nuklearnih osobina pomenutih tipova grafita.
Critical heat flux correlation for thin rectangular channels
International Nuclear Information System (INIS)
Tanaka, Futoshi; Mishima, Kaichiro; Hibiki, Takashi
2007-01-01
The effect of heated length on Critical heat flux (CHF) in thin rectangular channels was studied based on CHF data obtained under atmospheric pressure. CHF in small channels has been widely studied in the past decades but most of the studies are related to CHF in round tubes. Although basic mechanisms of burnout in thin rectangular channels are similar to tubes, applicability of CHF correlations for tubes to rectangular channels are questionable since CHF in rectangular channels are affected by the existence of non-heated walls and the non-circular geometry of channel circumference. Several studies of CHF in thin rectangular channels have been reported in relation to thermal hydraulic design of research reactors and neutron source targets and CHF correlations have been proposed, but the studies mostly focus on CHFs under geometrical conditions of the application of interest. In his study, existing CHF data obtained in thin rectangular channels were collected and the effect of heated length on CHF was examined. Existing CHF correlations were verified with positive quality flow CHF data but none of the correlations successfully reproduced the CHF for a wide range of heated length. A new CHF correlation for qualify region applicable to a wide range of heated length was developed based on the collected data. (author)
Directory of Open Access Journals (Sweden)
Tomasz Ząbkowski
2010-12-01
Full Text Available Kruszenie kamieni falą generowaną pozaustrojowo (extracorporeal shock wave lithotripsy, ESWL należy do podstawowych metod leczenia kamicy nerkowej – zyskała ona szerokie zastosowanie jako metoda małoinwazyjna i skuteczna. Wraz ze wzrostem doświadczenia urologów wykonujących zabiegi litotrypsji oraz udoskonalaniem litotryptorów wzrasta skuteczność wykonywanych zabiegów. Autorzy przedstawiają niezmiernie rzadkie powikłanie po zabiegu ESWL pod postacią pęknięcia nerki i masywnego krwawienia do przestrzeni zaotrzewnowej. Siedemdziesięcioośmioletni pacjent z małopłytkowością, po zabiegu by-passów (coronary artery bypass graft, CABG, po implantacji układu stymulującego serca, z nadciśnieniem tętniczym i cukrzycą typu II, leczony doustnymi antykoagulantami został przyjęty do Kliniki Urologicznej 6 godzin po zabiegu ESWL w trybie pilnym z powodu pogarszającego się stanu ogólnego, narastających dolegliwości bólowych w lewej okolicy lędźwiowej i masywnego krwiomoczu. Po przeprowadzeniu badania podmiotowego, przedmiotowego i na podstawie wykonanych badań dodatkowych (tomografia komputerowa jamy brzusznej rozpoznano pęknięcie nerki z masywnym krwiakiem przestrzeni zaotrzewnowej. Chorego zakwalifikowano w trybie pilnym do leczenia operacyjnego. Śródoperacyjnie stwierdzono ogromny krwiak wypełniający przestrzeń zaotrzewnową wokół nerki lewej i schodzący do lewego dołu biodrowego oraz masywne krwawienie z całej powierzchni uszkodzonej nerki bez możliwości opanowania krwawienia. Wobec powyższego obrazu podjęto decyzję o wycięciu nerki lewej. Z uwagi na stwierdzone płaszczyznowe krwawienie w otaczających tkankach i brak pewności co do ostatecznej hemostazy zdecydowano wykonać packing – założono 6 serwet do przestrzeni zaotrzewnowej. We wczesnym okresie pooperacyjnym nie stwierdzono powikłań. Pacjent krążeniowo, oddechowo i nerkowo wydolny. W 3. dobie od zabiegu w trybie planowym usuni
Directory of Open Access Journals (Sweden)
Motyka Oldřich
2011-09-01
Full Text Available Za účelem validace byla pro biomonitoring v průmyslem ovlivněném regionu Ostravska použita metoda, která dosud v České republice nebyla aplikována. Transplantáty dvou druhů mechů Hylocomium splendens a Pleurozium schreberi byly vystaveny atmosférickému znečištění pomocí metody “irrigated moss bag” ve výšce jak 1 m, tak 2 m nad zemí. Vzorky byly poté analyzovány za účelem zjištění koncentrace stopových prvků Al, As, Cd, Cr, Cu, Fe, Hg, Pb, V a Zn. Celkový průběh bioakumulace ukazuje, že je Hylocomium splendens pro biomonitoring vhodnější, stejně tak jako výška 2 m nad zemí.
Exercise training attenuates chemoreflex-mediated reductions of renal blood flow in heart failure.
Marcus, Noah J; Pügge, Carolin; Mediratta, Jai; Schiller, Alicia M; Del Rio, Rodrigo; Zucker, Irving H; Schultz, Harold D
2015-07-15
In chronic heart failure (CHF), carotid body chemoreceptor (CBC) activity is increased and contributes to increased tonic and hypoxia-evoked elevation in renal sympathetic nerve activity (RSNA). Elevated RSNA and reduced renal perfusion may contribute to development of the cardio-renal syndrome in CHF. Exercise training (EXT) has been shown to abrogate CBC-mediated increases in RSNA in experimental heart failure; however, the effect of EXT on CBC control of renal blood flow (RBF) is undetermined. We hypothesized that CBCs contribute to tonic reductions in RBF in CHF, that stimulation of the CBC with hypoxia would result in exaggerated reductions in RBF, and that these responses would be attenuated with EXT. RBF was measured in CHF-sedentary (SED), CHF-EXT, CHF-carotid body denervation (CBD), and CHF-renal denervation (RDNX) groups. We measured RBF at rest and in response to hypoxia (FiO2 10%). All animals exhibited similar reductions in ejection fraction and fractional shortening as well as increases in ventricular systolic and diastolic volumes. Resting RBF was lower in CHF-SED (29 ± 2 ml/min) than in CHF-EXT animals (46 ± 2 ml/min, P < 0.05) or in CHF-CBD animals (42 ± 6 ml/min, P < 0.05). In CHF-SED, RBF decreased during hypoxia, and this was prevented in CHF-EXT animals. Both CBD and RDNX abolished the RBF response to hypoxia in CHF. Mean arterial pressure increased in response to hypoxia in CHF-SED, but was prevented by EXT, CBD, and RDNX. EXT is effective in attenuating chemoreflex-mediated tonic and hypoxia-evoked reductions in RBF in CHF. Copyright © 2015 the American Physiological Society.
Angular dependence of SiO2 etch rate at various bias voltages in a high density CHF3 plasma
International Nuclear Information System (INIS)
Lee, Gyeo-Re; Hwang, Sung-Wook; Min, Jae-Ho; Moon, Sang Heup
2002-01-01
The dependence of the SiO 2 etch rate on the angle of ions incident on the substrate surface was studied over a bias voltage range from -20 to -600 V in a high-density CHF 3 plasma using a Faraday cage to control the ion incident angle. The effect of the bottom plane on the sidewall etching was also examined. Differences in the characteristics of the etch rate as a function of the ion angle were observed for different bias voltage regions. When the absolute value of the bias voltage was smaller than 200 V, the normalized etch rate (NER) defined as the etch rate normalized by the rate on the horizontal surface, changed following a cosine curve with respect to the ion incident angle, defined as the angle between the ion direction and the normal of the substrate surface. When the magnitude of the bias voltage was larger than 200 V, the NER was deviated to higher values from those given by a cosine curve at ion angles between 30 deg. and 70 deg. , and then drastically decreased at angles higher than 70 deg. until a net deposition was observed at angles near 90 deg. . The characteristic etch-rate patterns at ion angles below 70 deg. were determined by the ion energy transferred to the surface, which affected the SiO 2 etch rate and, simultaneously, the rate of removal of a fluorocarbon polymer film formed on the substrate surface. At high ion angles, particles emitted from the bottom plane contributed to polymer formation on and affected the etching characteristics of the substrate
Investigation of Critical Heat Flux in Reduced Gravity Using Photomicrographic Techniques
Mudawar, Issam; Zhang, Hui
2003-01-01
Experiments were performed to examine the effects of body force on flow boiling critical heat flux (CHF). FC-72 was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface just prior to CHF. High-speed video imaging techniques were used to identify dominant CHF mechanisms corresponding to different flow orientations and liquid velocities. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed significant sensitivity to orientation for flow velocities below 0.2 m/s, where extremely low CHF values where measured, especially with downward-facing heated wall and downflow orientations. High flow velocities dampened the effects of orientation considerably. The CHF data were used to assess the suitability of previous CHF models and correlations. It is shown the Interfacial Lift-off Model is very effective at predicting CHF for high velocities at all orientations. The flooding limit, on the other hand, is useful at estimating CHF at low velocities and for downflow orientations. A new method consisting of three dimensionless criteria is developed for determining the minimum flow velocity required to overcome body force effects on near-saturated flow boiling CHF. Vertical upflow boiling experiments were performed in pursuit of identifying the trigger mechanism for subcooled flow boiling CHF. While virtually all prior studies on flow boiling CHF concern the prediction or measurement of conditions that lead to CHF, this study was focused on events that take place during the CHF transient. High-speed video imaging and photomicrographic techniques were used to record the transient behavior of interfacial features from the last steady-state power level before CHF until the moment of power cut-off following CHF. The video records show the development of a wavy vapor layer which propagates
Anomalies and other concerns related to the critical heat flux
International Nuclear Information System (INIS)
Groeneveld, D.C.
2009-01-01
This paper summarizes various unusual trends in the critical heat flux (CHF) that have been observed experimentally in tubes. They include the following: Occurrence of a minimum in the CHF vs. quality (X) curve at high flows - leading to an initial upstream CHF occurrence in uniformly heated tubes. This phenomenon has been observed at high flows in both water and Freon. Occurrence of a limiting quality region on the CHF vs. X curve where the CHF drops by 30 - 90% for a nearly constant quality. This is thought to correspond to the boundary between the entrainment-controlled and the deposition-controlled region and causes problems for prediction methods of the form CHF=f(X). Impact of flow obstructions on the occurrence of upstream CHF and the limiting quality region. The additional mixing by grid spacers or bundle appendages results in a more homogeneous phase distribution, thus diminishing the effects of flow regime/heat transfer regime transitions responsible for the above unusual CHF trends. This will lead to a more gradually decreasing CHF vs. X curve. Absence of a CHF temperature excursion at high flows and high qualities - this is found to be caused by a change in slope of the transition boiling part of the boiling curve from a negative value (usual trend that results in a dryout temperature excursion) to a positive slope. Gradual disappearance of the sharp temperature excursion at CHF when increasing the pressure towards and beyond the critical pressure - no drastic change is observed in the shape of the axial temperature distribution of a heated tube experiencing CHF or heat transfer deterioration, when, for constant mass flux and inlet temperature, the pressure is gradually increased from subcritical to supercritical. CHF fluid-to-fluid modeling: differences in CHF behavior at certain conditions between refrigerants and water at equivalent conditions. The mechanisms responsible for these trends and the implications for predicting CHF for bundle geometries
Isothermal vapour-liquid equilibrium data for the binary systems of (CHF3 or C2F6) and n-heptane
International Nuclear Information System (INIS)
Williams-Wynn, Mark D.; Naidoo, Paramespri; Ramjugernath, Deresh
2016-01-01
Highlights: • Isothermal static-analytic and static-synthetic phase equilibrium measurements. • Binary VLE data for (CHF3 or C 2 F 6 ) + n-heptane. • Thermodynamic models were fitted to the experimental data. • Critical locus estimation for the systems. - Abstract: Isothermal vapour-liquid equilibrium (VLE) values for two binary systems; trifluoromethane and n-heptane at temperatures between T = (272.9 and 313.2) K, and hexafluoroethane and n-heptane at temperatures between T = (293.0 and 313.2) K were measured with a static-analytic apparatus. Bubble pressures at temperatures between T = (293.0 and 313.2) K, at several compositions, were also measured with a variable-volume static-synthetic apparatus. Vapour-liquid-liquid equilibrium (VLLE) was found to occur for certain isotherms for both of the systems. The PR EOS, with the Mathias-Copeman (MC) alpha function, combined with either the classical mixing rule or the Wong-Sandler (WS) mixing rule was used to correlate the experimental results. Either the NRTL or the UNIQUAC activity coefficient model was used within the WS mixing rule. The indirect extended scaling laws of Ungerer et al. were used to extrapolate critical loci from the experimental coexistence data, and the calculation procedure of Heidemann and Khalil was employed to calculate the mixture critical locus curves at temperatures close to the refrigerant critical temperatures. At lower temperatures on the mixture critical curve, gas-liquid critical points occurred, whereas, at higher temperatures, the critical points occurred along a liquid-liquid locus curve. The two systems were categorised according to the van Konynenburg and Scott classification.
Smith, Caleb A; Gillespie, Blanton R; Heard, George L; Setser, D W; Holmes, Bert E
2017-11-22
The recombination of CF 3 and CHF 2 radicals in a room-temperature bath gas was used to prepare vibrationally excited CF 3 CHF 2 * molecules with 101 kcal mol -1 of vibrational energy. The subsequent 1,2-H atom transfer and 1,1-HF and 1,2-HF elimination reactions were observed as a function of bath gas pressure by following the CHF 3 , CF 3 (F)C: and C 2 F 4 product concentrations by gas chromatography using a mass spectrometer as the detector. The singlet CF 3 (F)C: concentration was measured by trapping the carbene with trans-2-butene. The experimental rate constants are 3.6 × 10 4 , 4.7 × 10 4 , and 1.1 × 10 4 s -1 for the 1,2-H atom transfer and 1,1-HF and 1,2-HF elimination reactions, respectively. These experimental rate constants were matched to statistical RRKM calculated rate constants to assign threshold energies (E 0 ) of 88 ± 2, 88 ± 2, and 87 ± 2 kcal mol -1 to the three reactions. Pentafluoroethane is the only fluoroethane that has a competitive H atom transfer decomposition reaction, and it is the only example with 1,1-HF elimination being more important than 1,2-HF elimination. The trend of increasing threshold energies for both 1,1-HF and 1,2-HF processes with the number of F atoms in the fluoroethane molecule is summarized and investigated with electronic-structure calculations. Examination of the intrinsic reaction coordinate associated with the 1,1-HF elimination reaction found an adduct between CF 3 (F)C: and HF in the exit channel with a dissociation energy of ∼5 kcal mol -1 . Hydrogen-bonded complexes between HF and the H atom migration transition state of CH 3 (F)C: and the F atom migration transition state of CF 3 (F)C: also were found by the calculations. The role that these carbene-HF complexes could play in 1,1-HF elimination reactions is discussed.
A comparison of critical heat flux in tubes and bilaterally heated annuli
Energy Technology Data Exchange (ETDEWEB)
Doerffer, S.; Groeneveld, D.C.; Cheng, S.C. [Univ. of Ottawa (Canada)
1995-09-01
This paper examines the critical heat flux (CHF) behaviour for annular flow in bilaterally heated annuli and compares it to that in tubes and unilaterally heated annuli. It was found that the differences in CHF between bilaterally and unilaterally heated annuli or tubes strongly depend on pressure and quality. the CHF in bilaterally heated annuli can be predicted by tube CHF prediction methods for the simultaneous CHF occurrence at both surfaces, and the following flow conditions: pressure 7-10 MPa, mass flux 0.5-4.0 Mg/m{sup 2}s and critical quality 0.23-0.9. The effect on CHF of the outer-to-inner surface heat flux ratio, was also examined. The prediction of CHF for bilaterally heated annuli was based on the droplet-diffusion model proposed by Kirillov and Smogalev. While their model refers only to CHF occurrence at the inner surface, we extended it to cases where CHF occurs at the outer surface, and simultaneously at both surfaces, thus covering all cases of CHF occurrence in bilaterally heated annuli. From the annuli CHF data of Becker and Letzter, we derived empirical functions required by the model. the proposed equations provide good accuracy for the CHF data used in this study. Moreover, the equations can predict conditions at which CHF occurs simultaneously at both surfaces. Also, this method can be used for cases with only one heated surface.
International Nuclear Information System (INIS)
Lee, Kwang-Won; Baik, Se-Jin; Ro, Tae-Sun
2000-01-01
From a theoretical assessment of extensive critical heat flux (CHF) data under low pressure and low velocity (LPLV) conditions, it was found out that lots of CHF data would not be well predicted by a normal annular film dryout (AFD) mechanism, although their flow patterns were identified as annular-mist flow. To predict these CHF data, a liquid sublayer dryout (LSD) mechanism has been newly utilized in developing the mechanistic CHF model based on each identified CHF mechanism. This mechanism postulates that the CHF occurrence is caused by dryout of the thin liquid sublayer resulting from the annular film separation or breaking down due to nucleate boiling in annular film or hydrodynamic fluctuation. In principle, this mechanism well supports the experimental evidence of residual film flow rate at the CHF location, which can not be explained by the AFD mechanism. For a comparative assessment of each mechanism, the CHF model based on the LSD mechanism is developed together with that based on the AFD mechanism. The validation of these models is performed on the 1406 CHF data points ranging over P=0.1-2 MPa, G=4-499 kg m -2 s -1 , L/D=4-402. This model validation shows that 1055 and 231 CHF data are predicted within ±30 error bound by the LSD mechanism and the AFD mechanism, respectively. However, some CHF data whose critical qualities are <0.4 or whose tube length-to-diameter ratios are <70 are considerably overestimated by the CHF model based on the LSD mechanism. These overestimations seem to be caused by an inadequate CHF mechanism classification and an insufficient consideration of the flow instability effect on CHF. Further studies for a new classification criterion screening the CHF data affected by flow instabilities as well as a new bubble detachment model for LPLV conditions, are needed to improve the model accuracy.
International Nuclear Information System (INIS)
Moon, Sang Ki
1995-02-01
This thesis applies new information techniques, artificial neural networks, (ANNs) and fuzzy theory, to the investigation of the critical heat flux (CHF) phenomenon for water flow in vertical round tubes. The work performed are (a) classification and prediction of CHF based on fuzzy clustering and ANN, (b) prediction and parametric trends analysis of CHF using ANN with the introduction of dimensionless parameters, and (c) detection of CHF occurrence using fuzzy rule and spatiotemporal neural network (STN). Fuzzy clustering and ANN are used for classification and prediction of the CHF using primary system parameters. The fuzzy clustering classifies the experimental CHF data into a few data clusters (data groups) according to the data characteristics. After classification of the experimental data, the characteristics of the resulted clusters are discussed with emphasis on the distribution of the experimental conditions and physical mechanisms. The CHF data in each group are trained in an artificial neural network to predict the CHF. The artificial neural network adjusts the weight so as to minimize the prediction error within the corresponding cluster. Application of the proposed method to the KAIST CHF data bank shows good prediction capability of the CHF, better than other existing methods. Parametric trends of the CHF are analyzed by applying artificial neural networks to a CHF data base for water flow in uniformly heated vertical round tubes. The analyses are performed from three viewpoints, i.e., for fixed inlet conditions, for fixed exit conditions, and based on local conditions hypothesis. In order to remove the necessity of data classification, Katto and Groeneveld et al.'s dimensionless parameters are introduced in training the ANNs with the experimental CHF data. The trained ANNs predict the CHF better than any other conventional correlations, showing RMS error of 8.9%, 13.1%, and 19.3% for fixed inlet conditions, for fixed exit conditions, and for local
Anomalies and other concerns related to the critical heat flux
Energy Technology Data Exchange (ETDEWEB)
Groeneveld, D.C., E-mail: thermal@magma.ca [Researcher Emeritus, Chalk River Laboratories, Atomic Energy of Canada Ltd, Chalk River (Canada) and University of Ottawa, Department of Mechanical Engineering, Ottawa (Canada)
2011-11-15
This paper summarizes various unusual trends in the critical heat flux (CHF) that have been observed experimentally in tubes or bundle subassemblies. They include the following: Bullet Occurrence of a minimum in the CHF vs. quality (X) curve at high flows - leading to an initial upstream CHF occurrence in uniformly heated channels. This phenomenon has been observed at high flows in both water and Freon. Bullet Occurrence of a limiting quality region on the CHF vs. X curve where the CHF drops by 30-90% for a nearly constant quality. This is thought to correspond to the boundary between the entrainment controlled and the deposition controlled region and causes problems for prediction methods of the form CHF = f(X). Bullet Impact of flow obstructions on the occurrence of upstream CHF and the limiting quality region. The additional mixing by grid spacers or bundle appendages results in a more homogeneous phase distribution, and diminishes the effects of flow regime/heat transfer regime transitions responsible for some of the unusual CHF trends, and results in a more gradually decreasing CHF vs. X curve. Bullet Absence of a CHF temperature excursion at high flows and high qualities - this is found to be caused by a change in slope of the transition boiling part of the boiling curve from a negative value (usual trend that results in a temperature excursion) to a positive slope. Bullet Gradual disappearance of the sharp temperature excursion at CHF when increasing the pressure towards and beyond the critical pressure - no drastic change is observed in the axial temperature distribution of a heated tube experiencing CHF when, for constant mass flux and inlet temperature, the pressure is gradually increased from subcritical to supercritical. Bullet CHF fluid-to-fluid modelling: differences in CHF trends at certain conditions between refrigerants and water at equivalent conditions. The mechanisms responsible for these trends and the implications for bundle geometries are
Staff Association
2013-01-01
The « Théâtre de Carouge » offers a 5.- CHF discount for all shows (30.- CHF instead of 35.- CHF) and for the season tickets "Premières représentations" (132.- CHF instead of 162.- CHF) and "Classique" (150.- CHF instead of 180.- CHF). Please send your reservation by email to smills@tcag.ch via your professional email address. Please indicate the date of your reservation, your name and firstname and your telephone number A confirmation will be sent by email. Your membership card will be asked when you collect the tickets. More information on www.tcag.ch and www.tcag.ch/blog/
17O NMR parameters of some substituted benzyl ethers components: Ab initio study
Directory of Open Access Journals (Sweden)
Mahdi Rezaei Sameti
2016-09-01
Full Text Available The 17O NMR chemical shielding tensors and chemical shift for a set of substituted benzyl ethers derivatives containing (methyl, ethyl, isopropyl, t-butyl, brome and lithium have been calculated. The molecular structures were fully optimized using B3LYP/6-31G(d,p. The calculation of the 17O shielding tensors employed the GAUSSIAN 98 implementation of the gauge-including atomic orbital (GIAO and continuous set of gauge transformations (CSGT by using 6-31G (d,p, 6-31++G(d,p and 6-311++G(d,p basis set methods at density functional levels of theories (DFT. The values determined using the GIAO and CSGT were found to give a good agreement with the experimental chemical shielding.
Zhang, Dongze; Tu, Huiyin; Wang, Chaojun; Cao, Liang; Muelleman, Robert L; Wadman, Michael C; Li, Yu-Long
2017-01-01
Introduction: Ventricular arrhythmia is a major cause of sudden cardiac death in patients with chronic heart failure (CHF). Our recent study demonstrates that N-type Ca 2+ currents in intracardiac ganglionic neurons are reduced in the late stage of CHF rats. Rat intracardiac ganglia are divided into the atrioventricular ganglion (AVG) and sinoatrial ganglion. Only AVG nerve terminals innervate the ventricular myocardium. In this study, we tested the correlation of electrical remodeling in AVG neurons with ventricular arrhythmogenesis in CHF rats. Methods and Results: CHF was induced in male Sprague-Dawley rats by surgical ligation of the left coronary artery. The data from 24-h continuous radiotelemetry ECG recording in conscious rats showed that ventricular tachycardia/fibrillation (VT/VF) occurred in 3 and 14-week CHF rats but not 8-week CHF rats. Additionally, as an index for vagal control of ventricular function, changes of left ventricular systolic pressure (LVSP) and the maximum rate of left ventricular pressure rise (LV dP/dt max ) in response to vagal efferent nerve stimulation were blunted in 14-week CHF rats but not 3 or 8-week CHF rats. Results from whole-cell patch clamp recording demonstrated that N-type Ca 2+ currents in AVG neurons began to decrease in 8-week CHF rats, and that there was also a significant decrease in 14-week CHF rats. Correlation analysis revealed that N-type Ca 2+ currents in AVG neurons negatively correlated with the cumulative duration of VT/VF in 14-week CHF rats, whereas there was no correlation between N-type Ca 2+ currents in AVG neurons and the cumulative duration of VT/VF in 3-week CHF. Conclusion: Malignant ventricular arrhythmias mainly occur in the early and late stages of CHF. Electrical remodeling of AVG neurons highly correlates with the occurrence of ventricular arrhythmias in the late stage of CHF.
Chitin Fiber and Chitosan 3D Composite Rods
International Nuclear Information System (INIS)
Wang, Z.; Hu, Q.; Cai, L.
2010-01-01
Chitin fiber (CHF) and chitosan (CS) 3D composite rods with layer-by-layer structure were constructed by in situ precipitation method. CHF could not be dissolved in acetic acid aqueous solution, but CS could be dissolved due to the different deacetylation degree (D.D) between CHF and CS. CHF with undulate surfaces could be observed using SEM to demonstrate that the sufficiently rough surfaces and edges of the fiber could enhance the mechanical combining stress between fiber and matrix. XRD indicated that the crystallinity of CHF/CS composites decreased and CS crystal plane d-spacing of CHF/CS composites became larger than that of pure CS rod. TG analysis showed that mixing a little amount of CHF could enhance thermal stability of CS rod, but when the content of CHF was higher than the optimum amount, its thermal stability decreased. When 0.5% CHF was added into CS matrix, the bending strength and bending modulus of the composite rods arrived at 114.2 MPa and 5.2 GPa, respectively, increased by 23.6% and 26.8% compared with pure CS rods, indicating that CHF/CS composite rods could be a better candidate for bone fracture internal fixation.
On the look-up tables for the critical heat flux in tubes (history and problems)
Energy Technology Data Exchange (ETDEWEB)
Kirillov, P.L.; Smogalev, I.P. [Institute of Physics and Power Engineering, Kaluga (Russian Federation)
1995-09-01
The complication of critical heat flux (CHF) problem for boiling in channels is caused by the large number of variable factors and the variety of two-phase flows. The existence of several hundreds of correlations for the prediction of CHF demonstrates the unsatisfactory state of this problem. The phenomenological CHF models can provide only the qualitative predictions of CHF primarily in annular-dispersed flow. The CHF look-up tables covered the results of numerous experiments received more recognition in the last 15 years. These tables are based on the statistical averaging of CHF values for each range of pressure, mass flux and quality. The CHF values for regions, where no experimental data is available, are obtained by extrapolation. The correction of these tables to account for the diameter effect is a complicated problem. There are ranges of conditions where the simple correlations cannot produce the reliable results. Therefore, diameter effect on CHF needs additional study. The modification of look-up table data for CHF in tubes to predict CHF in rod bundles must include a method which to take into account the nonuniformity of quality in a rod bundle cross section.
International Nuclear Information System (INIS)
Robinson, H.L.; Lamoreux, W.F.
1976-01-01
Cells from three strains of Kimber Farms chickens, K16, K18, and K28, have been characterized for the expression of endogenous avian C-type virus (ALV) antigens and for susceptibility to subgroup E ALV. In K16 the coordinate dominant expression of chick helper factor (chf ), the type specific antigen of endogenous subgroup E ALV, and the group specific (gs) antigen of ALV was observed. The expression of chf and gs antigen in K16 chf + gs + cells was similar to that observed in SPAFAS and H and N gs + cells. In K18 chf but not gs antigen was expressed. The expression of chf in K18 chf + gs + cells was distinct from that observed for the chf + gs + pedigrees but similar to that found in SPAFAS chf + gs - helper extremely high (h/sub E/) cells. Cells from K16 and K18 chickens were uniformly resistant to subgroup E ALV. In cells from K28 chickens, susceptibility to subgroup B virus correlated with susceptibility to subgroup E virus. The efficiency of plating of subgroup E virus on susceptible K28 cells with 10 3 --10 4 -fold lower on chf + cells than on chf - cells
On the look-up tables for the critical heat flux in tubes (history and problems)
International Nuclear Information System (INIS)
Kirillov, P.L.; Smogalev, I.P.
1995-01-01
The complication of critical heat flux (CHF) problem for boiling in channels is caused by the large number of variable factors and the variety of two-phase flows. The existence of several hundreds of correlations for the prediction of CHF demonstrates the unsatisfactory state of this problem. The phenomenological CHF models can provide only the qualitative predictions of CHF primarily in annular-dispersed flow. The CHF look-up tables covered the results of numerous experiments received more recognition in the last 15 years. These tables are based on the statistical averaging of CHF values for each range of pressure, mass flux and quality. The CHF values for regions, where no experimental data is available, are obtained by extrapolation. The correction of these tables to account for the diameter effect is a complicated problem. There are ranges of conditions where the simple correlations cannot produce the reliable results. Therefore, diameter effect on CHF needs additional study. The modification of look-up table data for CHF in tubes to predict CHF in rod bundles must include a method which to take into account the nonuniformity of quality in a rod bundle cross section
Staff Association
2013-01-01
The warm weather arrives, it's time to take advantage of our offers Walibi and Aquapark! Walibi : Tickets "Zone terrestre": 21 € instead of 26 € Access to Aqualibi: 5 € instead of 8 € on presentation of your SA member ticket. Free for children (3-11 years old) before 12 h 00. Free for children under 3, with limited access to the attractions. Car park free. * * * * * Aquaparc : Half-day ticket (5 hours): – Children: 26 CHF instead of 35 CHF – Adults : 32 CHF instead of 43 CHF Day ticket: – Children: 30 CHF instead of 39 CHF – Adults : 36 CHF instead of 49 CHF Free for children under 5.
Gomes-Santos, Igor Lucas; Fernandes, Tiago; Couto, Gisele Kruger; Ferreira-Filho, Julio César Ayres; Salemi, Vera Maria Cury; Fernandes, Fernanda Barrinha; Casarini, Dulce Elena; Brum, Patricia Chakur; Rossoni, Luciana Venturini; de Oliveira, Edilamar Menezes; Negrao, Carlos Eduardo
2014-01-01
Accumulated evidence shows that the ACE-AngII-AT1 axis of the renin-angiotensin system (RAS) is markedly activated in chronic heart failure (CHF). Recent studies provide information that Angiotensin (Ang)-(1-7), a metabolite of AngII, counteracts the effects of AngII. However, this balance between AngII and Ang-(1-7) is still little understood in CHF. We investigated the effects of exercise training on circulating and skeletal muscle RAS in the ischemic model of CHF. Male Wistar rats underwent left coronary artery ligation or a Sham operation. They were divided into four groups: 1) Sedentary Sham (Sham-S), 2) exercise-trained Sham (Sham-Ex), sedentary CHF (CHF-S), and exercise-trained CHF (CHF-Ex). Angiotensin concentrations and ACE and ACE2 activity in the circulation and skeletal muscle (soleus and plantaris) were quantified. Skeletal muscle ACE and ACE2 protein expression, and AT1, AT2, and Mas receptor gene expression were also evaluated. CHF reduced ACE2 serum activity. Exercise training restored ACE2 and reduced ACE activity in CHF. Exercise training reduced plasma AngII concentration in both Sham and CHF rats and increased the Ang-(1-7)/AngII ratio in CHF rats. CHF and exercise training did not change skeletal muscle ACE and ACE2 activity and protein expression. CHF increased AngII levels in both soleus and plantaris muscle, and exercise training normalized them. Exercise training increased Ang-(1-7) in the plantaris muscle of CHF rats. The AT1 receptor was only increased in the soleus muscle of CHF rats, and exercise training normalized it. Exercise training increased the expression of the Mas receptor in the soleus muscle of both exercise-trained groups, and normalized it in plantaris muscle. Exercise training causes a shift in RAS towards the Ang-(1-7)-Mas axis in skeletal muscle, which can be influenced by skeletal muscle metabolic characteristics. The changes in RAS circulation do not necessarily reflect the changes occurring in the RAS of skeletal
Premature and stable critical heat flux for downward flow in a narrow rectangular channel
International Nuclear Information System (INIS)
Lee, Juhyung; Chang, Soon Heung; Jeong, Yong Hoon; Jo, Daeseong
2014-01-01
It has been recommended that RRs and MTRs be designed to have sufficient margins for CHF and the onset of FI as well, since unstable flow could leads to premature CHF under very low wall heat flux in comparison to stable CHF. Even the fact and previous studies, however, the understanding of relationship among FI, premature CHF and stable CHF is not sufficient to date. In this regards, subcooled flow boiling in a vertical rectangular channel was experimentally investigated to enhance the understanding of the CHF and the effect of the two-phase flow instability on it under low pressure conditions, especially for downward flow which was adopted for Jordan Research and Training Reactor (JRTR) and Kijang research reactor (KJRR) to achieve easier fuel and irradiation rig loading. In this study, CHF for downward flow of water under low pressure in narrow rectangular channel was experimentally investigated. For conditions such as downward flow, narrow rectangular channel and low pressure, it has been deduced from literature that flow instability could largely influence on triggering CHF at lower heat flux, i. e. premature CHF. Total 54 CHF data, which includes premature and stable data was obtained for various fluid conditions and system configurations including inlet stiffness. The upper and lower boundaries of CHF were newly proposed based on the experiment
International Nuclear Information System (INIS)
Jean-Marie Le Corre; Cristina H Amon; Shi-Chune Yao
2005-01-01
Full text of publication follows: The prediction of the Critical Heat Flux (CHF) in a heat flux controlled boiling heat exchanger is important to assess the maximal thermal capability of the system. In the case of a nuclear reactor, CHF margin gain (using improved mixing vane grid design, for instance) can allow power up-rate and enhanced operating flexibility. In general, current nuclear core design procedures use quasi-1D approach to model the coolant thermal-hydraulic conditions within the fuel bundles coupled with fully empirical CHF prediction methods. In addition, several CHF mechanistic models have been developed in the past and coupled with 1D and quasi-1D thermal-hydraulic codes. These mechanistic models have demonstrated reasonable CHF prediction characteristics and, more remarkably, correct parametric trends over wide range of fluid conditions. However, since the phenomena leading to CHF are localized near the heater, models are needed to relate local quantities of interest to area-averaged quantities. As a consequence, large CHF prediction uncertainties may be introduced and 3D fluid characteristics (such as swirling flow) cannot be accounted properly. Therefore, a fully mechanistic approach to CHF prediction is, in general, not possible using the current approach. The development of CHF-enhanced fuel assembly designs requires the use of more advanced 3D coolant properties computations coupled with a CHF mechanistic modeling. In the present work, the commercial CFD code CFX-5 is used to compute 3D coolant conditions in a vertical heated tube with upward flow. Several CHF mechanistic models at low quality available in the literature are coupled with the CFD code by developing adequate models between local coolant properties and local parameters of interest to predict CHF. The prediction performances of these models are assessed using CHF databases available in the open literature and the 1995 CHF look-up table. Since CFD can reasonably capture 3D fluid
Energy Technology Data Exchange (ETDEWEB)
Oi, Takao; Mitome, Ryota; Yanase, Satoshi [Sophia Univ., Tokyo (Japan). Faculty of Science and Technology
2017-06-01
H/D and {sup 12}C/{sup 13}C vapour pressure isotope effects (VPIEs) in liquid fluoroform (CHF{sub 3}) were studied at the MPW1PW91/6-31 ++ G(d) level of theory. The CHF{sub 3} monomer and CHF{sub 3} molecules surrounded by other CHF{sub 3} molecules in every direction in CHF{sub 3} clusters were used as model molecules of vapour and liquid CHF{sub 3}. Although experimental results in which the vapour pressure of liquid {sup 12}CHF{sub 3} is higher than that of liquid {sup 12}CDF{sub 3} and the vapour pressure of liquid {sup 13}CHF{sub 3} is higher than that of liquid {sup 12}CHF{sub 3} between 125 and 212 K were qualitatively reproduced, the present calculations overestimated the H/D VPIE and underestimated the {sup 12}C/{sup 13}C VPIE. Temperature-dependent intermolecular interactions between hydrogen and fluorine atoms of neighbouring molecules were required to explain the temperature dependences of both H/D and {sup 12}C/{sup 13}C VPIEs.
Staff Association
2011-01-01
Aquaparc Adults: 31 CHF instead of 42 CHF Children: 25 CHF instead of 34 CHF Aquaparc Les Caraïbes sur Léman 1807 Le Bouveret (VS) Tickets are valid for both the inside and outside areas.
Exercise training in older patients with systolic heart failure
DEFF Research Database (Denmark)
Prescott, Eva; Hjardem-Hansen, Rasmus; Dela, Flemming
2009-01-01
Training improves exercise capacity in patients with heart failure (CHF) but most evidence is on selected younger patients with systolic CHF.......Training improves exercise capacity in patients with heart failure (CHF) but most evidence is on selected younger patients with systolic CHF....
The film boiling look-up table: an improvement in predicting post-chf temperatures
International Nuclear Information System (INIS)
Groeneveld, D.C.; Leung, L.K.H.; Vasic, A.Z.; Guo, Y.J.; El Nakla, M.; Cheng, S.C.
2002-01-01
During the past 50 years more than 60 film boiling prediction methods have been proposed (Groeneveld and Leung, 2000). These prediction methods generally are applicable over limited ranges of flow conditions and do not provide reasonable predictions when extrapolated well outside the range of their respective database. Leung et al. (1996, 1997) and Kirillov et al. (1996) have proposed the use of a film-boiling look-up table as an alternative to the many models, equations and correlations for the inverted annular film boiling (IAFB) and the dispersed flow film-boiling (DFFB) regime. The film-boiling look-up table is a logical follow-up to the development of the successful CHF look-up table (Groeneveld et al., 1996). It is basically a normalized data bank of heat-transfer coefficients for discrete values of pressure, mass flux, quality and heat flux or surface-temperature. The look-up table proposed by Leung et al. (1996, 1997), and referred to as PDO-LW-96, was based on 14,687 data and predicted the surface temperature with an average error of 1.2% and an rms error of 6.73%. The heat-transfer coefficient was predicted with an average error of -4.93% and an rms error of 16.87%. Leung et al. clearly showed that the look-up table approach, as a general predictive tool for film-boiling heat transfer, was superior to the correlation or model approach. Error statistics were not provided for the look-up table proposed by Kirillov et al. (1996). This paper reviews the look-up table approach and describes improvements to the derivation of the film-boiling look-up table. These improvements include: (i) a larger data base, (ii) a wider range of thermodynamic qualities, (iii) use of the wall temperature instead of the heat flux as an independent parameter, (iv) employment of fully-developed film-boiling data only for the derivation of the look-up table, (v) a finer subdivision and thus more table entries, (vi) smoother table, and (vii) use of the best of five prediction methods
International Nuclear Information System (INIS)
Min Lee
1994-01-01
Critical heat flux (CHF) bundle data from the Heat Transfer Research Facility of Columbia University are used to check the validity of the CHF approaches used in thermal-hydraulic system analysis codes for light water reactors. The CHF approaches assessed include the Biasi et al. correlation of TRAC, the Groeneveld et al. CHF table lookup approach of RELAP5/MOD3, the CHF table lookup approach of CATHARE, and the CHF approach of RETRAN. Depending on system pressure, RETRAN uses the B and W2, Barnett, and modified Barnett correlations and a linear interpolation scheme to predict CHF. Results show that among these CHF approaches, the Groeneveld et al. approach has the best prediction accuracy and the smallest uncertainty in the estimation of the HTRF bundle data. On the average, the Groeneveld et al. approach overpredicts the uniform axial heat flux distribution by 3.6% and the nonuniform axial heat flux distribution by 0.9%. The performance of the RETRAN approach is comparable with that of the Groenevel et al. Approach for uniform axial heat flux. In general, the accuracy and the uncertainty of all the approaches, except that of CATHARE, are worse under a nonuniform axial heat distribution than under a uniform axial heat distribution. All the CHF approaches assessed have a tendency to overpredict the HTRF bundle data at low pressure, low measured CHF, and high CHF quality. The performance of the Groenevel et al. approach is improved through a CHF table update and modification of the bundle correction factor using the HTRF bundle data
Staff Association
2010-01-01
For members of the Staff Association Aquaparc is celebrating its 10th anniversary We have a limited number of Aquaparc tickets valid for the whole day at the following prices: adult: 28 CHF instead of 46 CHF child: 23 CHF instead of 38 CHF
Critical heat flux of water in vertical tubes with an upper plenum and a closed bottom
International Nuclear Information System (INIS)
Kim, Hong Chae; Baek, Won Pil; Chang, Soon Heung
2000-01-01
An experimental study is conducted for vertical round tubes with an upper plenum and a closed bottom to investigate CHF behavior and CHF onset location under the counter-current condition. The measured CHF values are well predicted by general Wallis type flooding correlations. A 1-D steady state analytical flooding model for thermosyphon by El-Genk and Saber was assessed with the data and the liquid film thickness at the liquid entrance was calculated. The CHF onset position becomes different with L/D and D, and liquid entrance geometry affects only CHF values not CHF onset positions
Staff Association
2014-01-01
Passeport Gourmand Are you dying for a nice meal? The “Passeport Gourmand” offers discounted prices to the members of the Staff Association (available until April 2015 and on sale in the Staff Association Secretariat): Passeport gourmand Ain / Savoie/ Haute Savoie: 56 CHF instead of 79 CHF. Passeport gourmand Geneva / neighbouring France:72 CHF instead of 95 CHF. To the members of the Staff Association: Benefit of reduced tickets: CHF 10 (instead of 18 CHF at the desk) on sale to the secretariat of the Staff Association, Building 510-R010 (in front of the Printshop).
Chitin Fiber and Chitosan 3D Composite Rods
Directory of Open Access Journals (Sweden)
Zhengke Wang
2010-01-01
Full Text Available Chitin fiber (CHF and chitosan (CS 3D composite rods with layer-by-layer structure were constructed by in situ precipitation method. CHF could not be dissolved in acetic acid aqueous solution, but CS could be dissolved due to the different deacetylation degree (D.D between CHF and CS. CHF with undulate surfaces could be observed using SEM to demonstrate that the sufficiently rough surfaces and edges of the fiber could enhance the mechanical combining stress between fiber and matrix. XRD indicated that the crystallinity of CHF/CS composites decreased and CS crystal plane d-spacing of CHF/CS composites became larger than that of pure CS rod. TG analysis showed that mixing a little amount of CHF could enhance thermal stability of CS rod, but when the content of CHF was higher than the optimum amount, its thermal stability decreased. When 0.5% CHF was added into CS matrix, the bending strength and bending modulus of the composite rods arrived at 114.2 MPa and 5.2 GPa, respectively, increased by 23.6% and 26.8% compared with pure CS rods, indicating that CHF/CS composite rods could be a better candidate for bone fracture internal fixation.
International Nuclear Information System (INIS)
Park, Sung Seek; Kim, Yong Hwan; Kim, Nam Jin
2013-01-01
The results of this experiment were that the CHF of the two nanofluids increased along with the volumetric fraction until 0.001 vol%, and the two types of nanofluids are the highest CHF at 0.001 vol%. Also, the results show clearly that the rate of CHF increase of the CM-100 MWCNT nanofluid with longer-length nanoparticles is higher than that of the CM-95 MWNCT nanofluid. These results indicate that the length of carbon nanotube influences the pool boiling CHF of carbon nanotube nanofluid and that long-length MWCNT, as above-noted, offers a superior effect in this regard. Boiling heat transfer is used in a variety of industrial processes and applications, such as refrigeration, power generation, heat exchangers, cooling of high-power electronics components and cooling of nuclear reactors. The critical heat flux (CHF) phenomenon is the thermal limit during a boiling heat transfer phase change; at the CHF point the heat transfer is maximised, followed by a drastic degradation after the CHF point. The consequence is a substantial increase in wall temperature which may result in physical failure phenomenon of heat transfer systems. Therefore, the CHF is important being considered in the cooling device design, such as nuclear reactor and nuclear fuels, steam generators, high-density electronic component, etc. And, CHF enhancement is essential for safety of heat transfer system. Recently, CHF reported increased when applied to the nanofluids, with its high (higher-than-base-fluid) thermal characteristic in the nuclear power plant system. Therefore, in this study, carried out the pool boiling CHF experiments by the particle length using carbon nanotube nanofluids, and the results are compared and analyzed for the CHF enhancement. The pool boiling CHF of experiments of carbon nanotube nanofluids carried out by the length of particles and the various concentrations
International Nuclear Information System (INIS)
Kim, Seol Ha; Kang, Jun Young; Lee, Gi Chol; Kiyofumia, Moriyama; Kim, Moo Hwan; Park, Hyun Sun
2015-01-01
In general, the evaluation of the boiling performance mainly focuses on two physical parameters: boiling heat transfer (BHT) and critical heat flux (CHF). In the nuclear power plants, both BHT and CHF contribute the nuclear system efficiency and safety, respectively. In this study, BHT and CHF of the pool boiling on well-organized fabricated structured (micro scaled) surface has been evaluated. As a results, BHT change on microstructured surface shows strongly dependent on Pin-fin effect analysis. In terms of CHF, critical size of micro structure for CHF enhancement has been observed and analyzed based on the capillary wicking effect. In this study, BHT and CHF of the pool boiling on well-organized fabricated structured (micro scaled) surface has been evaluated. As a results, BHT change on microstructured surface shows strongly dependent on the roughness ratio. The extended heat transfer area contributes the boiling heat transfer increase on the structured surface, and its quantitative analysis has been performed. In terms of CHF, the critical size of micro structure for CHF enhancement has been observed and analyzed based on the capillary wicking effect. We suggested a capillary limit to CHF delay for modeling capillary induced liquid inflow through microstructured surfaces. The critical size of the capillary limit on the prepared structured surface, determined by a model, could be reasonable explanation points for the experimental results (optimal size for CHF delay). The present experimental results also showed clearly the critical size (10 - 20 μm) for CHF delay, predicted by capillary limit analysis. This study provides fundamental insight into BHT and CHF enhancement of structured surfaces, and an optimal design guide for the required CHF and boiling heat-transfer performance. Finally, this study can contribute the basic understanding of the boiling on designed microstructure surface, and it also suggest the optimal micro scaled structured surface of boiling
Integrated CAD/CAE for nuclear power plants
International Nuclear Information System (INIS)
Lecoq, P.; Lachat, J.C.
1987-01-01
The size of the French nuclear power program has led both EDF and Framatome to equip themselves progressively with management software, computer-assisted design (CAD) systems, and computer-assisted engineering (CAE) systems. The nature of the projects and of the respective activities of EDF and Framatome determined the essential specifications of these computerized systems. EDF and Framatome have pooled their CAD/CAE efforts in a joint venture (Groupement d'Interet Economique) called GIAO, set up in 1985 by EDF and Aquitaine Systeme (a subsidiary of Framatome and Elf Aquitaine). GIAO's ambition is to become a pole of French CAD/CAE efforts and to foster progress in integrated computer-assisted engineering, by enlarging the synergy of EDF and Framatome in this field to other enterprises that participate in design and construction of complex industrial plants
The effects of transient conditions on the onset of intermittent dryout during blowdown
Energy Technology Data Exchange (ETDEWEB)
Statham, B.A., E-mail: stathaba@mcmaster.ca; Novog, D.R., E-mail: novog@mcmaster.ca
2017-06-15
Highlights: • This papers presents the results of an experimental investigation of transient critical heat flux in high quality and intermediate pressure water. • In existing literature conclusions vary from those showing no effect of transient conditions to results which show 30–40% improvement in CHF. • Along with new CHF data points in the liquid film dominated flow regime, the authors provide a methodology for producing bias free estimates of CHF based on existing correlations. • With these bias free CHF estimates, comparisons are made between transient and steady-state CHF at comparable local conditions. • The work concludes that based on consistently collected and analyzed data that quasi-steady CHF experiments adequately predict transient CHF using the same local thermalhydraulic conditions. - Abstract: For a given set of conditions in a boiling system the point of liquid film dryout or departure from nucleate boiling corresponds to the change from convective or nucleate boiling to transition or film boiling. This change is associated with a rapid deterioration of the heat transfer coefficient and the heat flux at this transition is denoted the critical heat flux (CHF). Computer models used to predict station transients and CHF rely heavily on empirical correlations to predict the CHF. Liquid film CHF data are usually obtained using a quasi-steady method wherein the heat flux is incremented in small steps with each step being allowed to reach a new equilibrium until an abnormal temperature increase is detected on the experimental surfaces. In applying a correlation derived from steady-state experiments to transient analyses these codes implicitly assume that dryout will occur for the same local conditions during transients as during steady state conditions. There is some disagreement in literature as to the validity of this hypothesis. This paper provides new steady-state and transient experimental data for CHF in water at intermediate pressures
Mordi, Natalie A; Mordi, Ify R; Singh, Jagdeep S; Baig, Fatima; Choy, Anna-Maria; McCrimmon, Rory J; Struthers, Allan D; Lang, Chim C
2017-01-01
Introduction Type 2 diabetes (T2D) and heart failure (HF) are a frequent combination, where treatment options remain limited. There has been increasing interest around the sodium–glucose cotransporter 2 (SGLT2) inhibitors and their use in patients with HF. Data on the effect of SGLT2 inhibitor use with diuretics are limited. We hypothesise that SGLT2 inhibition may augment the effects of loop diuretics and the benefits of SGLT2 inhibitors may extend beyond those of their metabolic (glycaemic parameters and weight loss) and haemodynamic parameters. The effects of SGLT2 inhibitors as an osmotic diuretic and on natriuresis may underlie the cardiovascular and renal benefits demonstrated in the recent EMPA-REG study. Methods and analysis To assess the effect of SGLT2 inhibitors when used in combination with a loop diuretic, the RECEDE-CHF (Renal and Cardiovascular Effects of SGLT2 inhibition in combination with loop Diuretics in diabetic patients with Chronic Heart Failure) trial is a single-centre, randomised, double-blind, placebo-controlled, cross-over trial conducted in a secondary care setting within NHS Tayside, Scotland. 34 eligible participants, aged between 18 and 80 years, with stable T2D and CHF will be recruited. Renal physiological testing will be performed at two points (week 1 and week 6) on each arm to assess the effect of 25 mg empagliflozin, on the primary and secondary outcomes. Participants will be enrolled in the trial for a total period between 14 and 16 weeks. The primary outcome will assess the effect of empagliflozin versus placebo on urine output. The secondary outcomes are to assess the effect of empagliflozin on glomerular filtration rate, cystatin C, urinary sodium excretion, urinary protein/creatinine ratio and urinary albumin/creatinine ratio when compared with placebo. Ethics and dissemination Ethics approval was obtained by the East of Scotland Research Ethics Service. Results of the trial will be submitted for publication in a peer
International Nuclear Information System (INIS)
Yuan, Lan Qin; Yang, Jun; Harrison, Noel
2014-01-01
Fuel irradiation experiments to study fuel behaviors have been performed in the experimental loops of the National Research Universal (NRU) Reactor at Atomic Energy of Canada Limited (AECL) Chalk River Laboratories (CRL) in support of the development of new fuel technologies. Before initiating a fuel irradiation experiment, the experimental proposal must be approved to ensure that the test fuel strings put into the NRU loops meet safety margin requirements in critical heat flux (CHF). The fuel strings in irradiation experiments can have varying degrees of fuel enrichment and burnup, resulting in large variations in radial heat flux distribution (RFD). CHF experiments performed in Freon flow at CRL for full-scale bundle strings with a number of RFDs showed a strong effect of RFD on CHF. A prediction method was derived based on experimental CHF data to account for the RFD effect on CHF. It provides good CHF predictions for various RFDs as compared to the data. However, the range of the tested RFDs in the CHF experiments is not as wide as that required in the fuel irradiation experiments. The applicability of the prediction method needs to be examined for the RFDs beyond the range tested by the CHF experiments. The Canadian subchannel code ASSERT-PV was employed to simulate the CHF behavior for RFDs that would be encountered in fuel irradiation experiments. The CHF predictions using the derived method were compared with the ASSERT simulations. It was observed that the CHF predictions agree well with the ASSERT simulations in terms of CHF, confirming the applicability of the prediction method in fuel irradiation experiments. (author)
AB INITIO STUDY, INVESTIGATION OF NMR SHIELDING ...
African Journals Online (AJOL)
Preferred Customer
invariant atomic orbital (GIAO) method was employed to calculate isotropic atomic .... 298 K in order to obtain entropy (S) and free energy (G) variation for the considered process. ... well as epoxides, organic halides and activated alkenes.
International Nuclear Information System (INIS)
Moon, S.K.; Chun, S.Y.; Choi, K.Y.; Yang, S.K.
2001-01-01
An experimental study on transient critical heat flux (CHF) under flow coast-down has been performed for water flow in a non-uniformly heated vertical annulus under low flow and a wide range of pressure conditions. The objectives of this study are to systematically investigate the effect of the flow transient on the CHF and to compare the transient CHF with steady state CHF. The transient CHF experiments have been performed for three kinds of flow transient modes based on the coast-down data of the Kori 3/4 nuclear power plant reactor coolant pump. Most of the CHFs occurred in the annular-mist flow regime. Thus, it means that the possible CHF mechanism might be the liquid film dryout in the annular-mist flow regime. For flow transient mode with the smallest flow reduction rate, the time-to-CHF is the largest. At the same inlet subcooling, system pressure and heat flux, the effect of the initial mass flux on the critical mass flux can be negligible. However, the effect of the initial mass flux on the time-to-CHF becomes large as the heat flux decreases. Usually, the critical mass flux is large for slow flow reduction. There is a pressure effect on the ratio of the transient CHF data to steady state CHF data. Some conventional correlations show relatively better CHF prediction results for high system pressure, high quality and slow transient modes than for low system pressure, low quality and fast transient modes. (author)
Directory of Open Access Journals (Sweden)
Anna eFrey
2014-10-01
Full Text Available Background-Depression and anxiety are common and independent outcome predictors in patients with chronic heart failure (CHF. However, it is unclear whether CHF causes depression. Thus, we investigated whether mice develop anxiety- and depression-like behavior after induction of ischemic CHF by myocardial infarction (MI.Methods and Results- In order to assess depression-like behavior, anhedonia was investigated by repeatedly testing sucrose preference for 8 weeks after coronary artery ligation or sham operation. Mice with large MI and increased left ventricular dimensions on echocardiography (termed CHF mice showed reduced preference for sucrose, indicating depression-like behavior. 6 weeks after MI, mice were tested for exploratory activity, anxiety-like behavior and cognitive function using the elevated plus maze (EPM, light-dark box (LDB, open field (OF and object recognition (OR tests. In the EPM and OF, CHF mice exhibited diminished exploratory behavior and motivation despite similar movement capability. In the OR, CHF mice had reduced preference for novelty and impaired short-term memory. On histology, CHF mice had unaltered overall cerebral morphology. However, analysis of gene expression by RNA-sequencing in prefrontal cortical, hippocampal, and left ventricular tissue revealed changes in genes related to inflammation and cofactors of neuronal signal transduction in CHF mice, with Nr4a1 being dysregulated both in prefrontal cortex and myocardium after MI. Conclusions-After induction of ischemic CHF, mice exhibited anhedonic behavior, decreased exploratory activity and interest in novelty, and cognitive impairment. Thus, ischemic CHF leads to distinct behavioral changes in mice analogous to symptoms observed in humans with CHF and comorbid depression.
Development of the Heated Length Correction Factor
International Nuclear Information System (INIS)
Park, Ho-Young; Kim, Kang-Hoon; Nahm, Kee-Yil; Jung, Yil-Sup; Park, Eung-Jun
2008-01-01
The Critical Heat Flux (CHF) on a nuclear fuel is defined by the function of flow channel geometry and flow condition. According to the selection of the explanatory variable, there are three hypotheses to explain CHF at uniformly heated vertical rod (inlet condition hypothesis, exit condition hypothesis, local condition hypothesis). For inlet condition hypothesis, CHF is characterized by function of system pressure, rod diameter, rod length, mass flow and inlet subcooling. For exit condition hypothesis, exit quality substitutes for inlet subcooling. Generally the heated length effect on CHF in exit condition hypothesis is smaller than that of other variables. Heated length is usually excluded in local condition hypothesis to describe the CHF with only local fluid conditions. Most of commercial plants currently use the empirical CHF correlation based on local condition hypothesis. Empirical CHF correlation is developed by the method of fitting the selected sensitive local variables to CHF test data using the multiple non-linear regression. Because this kind of method can not explain physical meaning, it is difficult to reflect the proper effect of complex geometry. So the recent CHF correlation development strategy of nuclear fuel vendor is making the basic CHF correlation which consists of basic flow variables (local fluid conditions) at first, and then the geometrical correction factors are compensated additionally. Because the functional forms of correction factors are determined from the independent test data which represent the corresponding geometry separately, it can be applied to other CHF correlation directly only with minor coefficient modification
Critical heat flux tests for self-spaced square finned 7 fuel rod bundle
International Nuclear Information System (INIS)
Moon, Sang Ki; Chun, Se Young; Choi, Ki Young; Park, Jong Kuk; Hwang, Dae Hyun; Zee, Sung Quun; Kim, Keung Koo
2001-09-01
Now, KAERI is developing a new advanced reactor aimed at achieving highly enhanced safety and reliability, and improved economics. SSF (Self-Spaced Square Finned) fuel rod bundle is considered as a suitable one for the new advanced reactor. The SSF fuel rods have rectangular shapes and four fins at the corners, and are arranged in triangular geometry. While the SSF fuel rod bundle is considered to have enhanced cooling efficiency, the correlations used for commercial PWR might be able to be applied. The application results of some conventional correlations show that the SSF fuel rod bundle show an enhanced CHF performance about 10 to 40 %. When some conventional CHF correlations are applied to CHF data with a similar geometry to the SSF fuel rod bundle, conventional CHF correlations including a correlation developed in Russia are judged not to be suitable for the development of SSF fuel rod bundle and for the use in a safety analysis code. From CHF experiments for SSF 7 fuel rod bundle performed in KAERI, the following results are obtained: the CHF increases with increasing mass flux, and the CHF increasing rate decreases at high mass flux conditions. The exit quality decreases with increasing mass flux. The overall effect of the mass flux on the CHF and exit quality coincides with previous understanding. Compared to the CHF data of IPPE with the same system pressure and inlet temperature, the CHF data of KAERI show the similar values. Thus, the reliability of IPPE CHF data can be confirmed indirectly
Directory of Open Access Journals (Sweden)
Kristin Dawson
Full Text Available Fibroblasts are important in the atrial fibrillation (AF substrate resulting from congestive heart failure (CHF. We previously noted changes in in vivo indices of fibroblast function in a CHF dog model, but could not detect changes in isolated cells. This study assessed CHF-induced changes in the phenotype of fibroblasts freshly isolated from control versus CHF dogs, and examined effects of cell culture on these differences.Left-atrial fibroblasts were isolated from control and CHF dogs (ventricular tachypacing 240 bpm × 2 weeks. Freshly-isolated fibroblasts were compared to fibroblasts in primary culture. Extracellular-matrix (ECM gene-expression was assessed by qPCR, protein by Western blot, fibroblast morphology with immunocytochemistry, and K(+-current with patch-clamp. Freshly-isolated CHF fibroblasts had increased expression-levels of collagen-1 (10-fold, collagen-3 (5-fold, and fibronectin-1 (3-fold vs. control, along with increased cell diameter (13.4 ± 0.4 µm vs control 8.4 ± 0.3 µm and cell spreading (shape factor 0.81 ± 0.02 vs. control 0.87 ± 0.02, consistent with an activated phenotype. Freshly-isolated control fibroblasts displayed robust tetraethylammonium (TEA-sensitive K(+-currents that were strongly downregulated in CHF. The TEA-sensitive K(+-current differences between control and CHF fibroblasts were attenuated after 2-day culture and eliminated after 7 days. Similarly, cell-culture eliminated the ECM protein-expression and shape differences between control and CHF fibroblasts.Freshly-isolated CHF and control atrial fibroblasts display distinct ECM-gene and morphological differences consistent with in vivo pathology. Culture for as little as 48 hours activates fibroblasts and obscures the effects of CHF. These results demonstrate potentially-important atrial-fibroblast phenotype changes in CHF and emphasize the need for caution in relating properties of cultured fibroblasts to in vivo systems.
GRACE score predicts heart failure admission following acute coronary syndrome.
McAllister, David A; Halbesma, Nynke; Carruthers, Kathryn; Denvir, Martin; Fox, Keith A
2015-04-01
Congestive heart failure (CHF) is a common and preventable complication of acute coronary syndrome (ACS). Nevertheless, ACS risk scores have not been shown to predict CHF risk. We investigated whether the at-discharge Global Registry of Acute Coronary Events (GRACE) score predicts heart failure admission following ACS. Five-year mortality and hospitalization data were obtained for patients admitted with ACS from June 1999 to September 2009 to a single centre of the GRACE registry. CHF was defined as any admission assigned WHO International Classification of Diseases 10 diagnostic code I50. The hazard ratio (HR) for CHF according to GRACE score was estimated in Cox models adjusting for age, gender and the presence of CHF on index admission. Among 1,956 patients, CHF was recorded on index admission in 141 patients (7%), and 243 (12%) were admitted with CHF over 3.8 median years of follow-up. Compared to the lowest quintile, patients in the highest GRACE score quintile had more CHF admissions (116 vs 17) and a shorter time to first admission (1.2 vs 2.0 years, HR 9.87, 95% CI 5.93-16.43). Per standard deviation increment in GRACE score, the instantaneous risk was more than two-fold higher (HR 2.28; 95% CI 2.02-2.57), including after adjustment for CHF on index admission, age and gender (HR 2.49; 95% CI 2.06-3.02). The C-statistic for CHF admission at 1-year was 0.74 (95% CI 0.70-0.79). The GRACE score predicts CHF admission, and may therefore be used to target ACS patients at high risk of CHF with clinical monitoring and therapies. © The European Society of Cardiology 2014.
Dynamic Response of Plant Chlorophyll Fluorescence to Light, Water and Nutrient Availability
Cendrero Mateo, M. D. P.; Moran, S. M.; Porcar-Castell, A.; Carmo-Silva, A. E.; Papuga, S. A.; Matveeva, M.; Wieneke, S.; Rascher, U.
2014-12-01
Photosynthesis is the most important exchange process of CO2 between the atmosphere and the land-surface. Spatial and temporal patterns of photosynthesis depend on dynamic plant-specific adaptation strategies to highly variable environmental conditions e.g. light, water, and nutrient availability. Chlorophyll fluorescence (ChF) has been proposed as a direct indicator of photosynthesis, and several studies have demonstrated its relationship with vegetation functioning at leaf and canopy level. In this study, two overarching questions about ChF were addressed: Q1) How water, nutrient and ambient light conditions determine the relationships between photosynthesis and ChF? Which is the optimum irradiance level for detecting water and nutrient deficit conditions with ChF?; Q2) What is the seasonal relationship between photosynthesis and ChF when nitrogen is the limiting factor? The results of this study indicated that when the differences between treatments (water or nitrogen) drive the relationship between photosynthesis and ChF, ChF has a direct relationship with photosynthesis. This study demonstrates that the light level at which plants were grown was optimum for detecting water and nutrient deficit with ChF. Further, the seasonal relation between photosynthesis and ChF with nitrogen stress was not a simple linear function due to the complex physiological relation between photosynthesis and ChF. Our study showed that at times in the season when nitrogen was sufficient and photosynthesis was highest, ChF decreased because these two processes compete for available energy. The results from this study demonstrated that ChF is a reliable indicator of plant stress and has great potential as a tool for better understand where, when, and how CO2 is exchanged between the land and atmosphere.
Staff Association
2017-01-01
The “La Comédie” theatre unveiled its programme for the season 2017–2018. We are delighted to share this brand new, rich and varied programme with you. The “La Comédie” theatre has various discounts for our members Buy 2 subscriptions for the price of 1 : 2 cards “Libertà” for CHF 240.- instead of CHF 480.- Cruise freely through the season with an 8-entry card valid for the shows of your choice. These cards are transferable and can be shared with one or more accompanying persons. 2 cards “Piccolo” for CHF 120 instead of CHF 240.- This card lets you discover 4 shows which are suitable for all audiences (offers valid while stock lasts) Benefit from a reduction of 20 % on a full price ticket during all the season: from CHF 40.- to CHF 24.- ticket instead of CHF 50.- to CHF 30.- depending on the show (Also valid for one accompanying person). Interested in one of these offers? Create an ac...
Staff Association
2015-01-01
New season 2015-2016 The new season was revealed in May, and was warmly welcomed by the press, which is especially enthusiastic about the exceptional arrival of Fanny Ardand in September in the framework of Cassandre show. Discover the programme 2015-2016. The theatre La Comédie proposes different offers to our members Benefit from a reduction of 20 % on a full price ticket during all the season: from 38 CHF to 23 CHF ticket instead of 50 CHF to 30 CHF depending on the show. Buy two seasonal tickets at the price of one (offers valid upon availability, and until 30 september 2015) 2 Cards Libertà for 240 CHF instead of 480 CHF. Cruise freely through the season with 8 perfomances of your choice per season. These cards are transferrable, and can be shared with one or more accompanying persons. 2 Abo Piccolo for 120 CHF instead of 240 CHF. Let yourself be surprised a theatre performance with our discovery seasonal tickets, which includes 4 flagship perfomances for the season. ...
Directory of Open Access Journals (Sweden)
B. U. Mardanov
2016-01-01
Full Text Available This review is devoted to the study of issues relating to the features of associated course of chronic heart failure (CHF and diabetes mellitus (DM. The modern views on the epidemiology, pathogenesis of DM and CHF are systematized. The pathogenesis of diabetic cardiomyopathy is described in details. The results of the well-known studies that show the negative impact of DM on CHF prognosis are presented. The principles of CHF pathogenetic therapy in patients with DM including the role of neurohormonal modulators are analyzed. The results of multicenter studies in patients with CHF and concomitant DM type 2 show that almost all first-line drugs recommended for CHF treatment are effective in patients with DM.
Staff Association
2013-01-01
SPECIAL OFFER FOR OUR MEMBERS Prices Spring and Summer 2013 Day ticket: same price weekends, public holidays and weekdays: Children from 5 to 15 years old: 30 CHF instead of 39 CHF Adults from 16 years old: 36 CHF instead of 49 CHF Bonus! Free for children under 5 Tickets available at the Staff Association Secretariat.
Association du personnel
2013-01-01
SPECIAL OFFER FOR OUR MEMBERS Prices Spring and Summer 2013 Day ticket: same price weekends, public holidays and weekdays: – Children from 5 to 15 years old: 30 CHF instead of 39 CHF – Adults from 16 years old: 36 CHF instead of 49 CHF – Bonus! Free for children under 5 Tickets available at the Staff Association Secretariat.
TREATMENT OF CHRONIC HEART FAILURE: FOCUS ON METOPROLOL SUCCINATE
Directory of Open Access Journals (Sweden)
O. D. Ostroumova
2012-01-01
Full Text Available Advantages of metoprolol succinate in patients with chronic heart failure (CHF are covered. Results of MERIT-HF study are taken as the main evidences. Patterns of the metoprolol succinate use in the treatment of different categories of patients with CHF (women, the elderly , severe CHF forms, CHF with concomitant hypertension or diabetes are considered.
TREATMENT OF CHRONIC HEART FAILURE: FOCUS ON METOPROLOL SUCCINATE
Directory of Open Access Journals (Sweden)
O. D. Ostroumova
2015-12-01
Full Text Available Advantages of metoprolol succinate in patients with chronic heart failure (CHF are covered. Results of MERIT-HF study are taken as the main evidences. Patterns of the metoprolol succinate use in the treatment of different categories of patients with CHF (women, the elderly , severe CHF forms, CHF with concomitant hypertension or diabetes are considered.
Abassi, Zaid A; Barac, Yaron D; Kostin, Sawa; Roguin, Ariel; Ovcharenko, Elena; Awad, Hoda; Blank, Ayelet; Bar-Am, Orit; Amit, Tamar; Schaper, Jutta; Youdim, Moussa; Binah, Ofer
2011-07-01
Despite the availability of many pharmacological and mechanical therapies, the mortality rate among patients with congestive heart failure (CHF) remains high. We tested the hypothesis that TVP1022 (the S-isomer of rasagiline; Azilect), a neuroprotective and cytoprotective molecule, is also cardioprotective in the settings of experimental CHF in rats. In rats with volume overload-induced CHF, we investigated the therapeutic efficacy of TVP1022 (7.5 mg/kg) on cardiac function, structure, biomarkers, and kidney function. Treatment with TVP1022 for 7 days before CHF induction prevented the increase in left ventricular end-diastolic area and end-systolic area, and the decrease in fractional shortening measured 14 days after CHF induction. Additionally, TVP1022 pretreatment attenuated CHF-induced cardiomyocyte hypertrophy, fibrosis, plasma and ventricular B-type natriuretic peptide levels, and reactive oxygen species expression. Further, in CHF rats, TVP1022 decreased cytochrome c and caspase 3 expression, thereby contributing to the cardioprotective efficacy of the drug. TVP1022 also enhanced the urinary Na(+) excretion and improved the glomerular filtration rate. Similar cardioprotective effects were obtained when TVP1022 was given to rats after CHF induction. TVP1022 attenuated the adverse functional, structural, and molecular alterations in CHF, rendering this drug a promising candidate for improving cardiac and renal function in this disease state.
Prediction of critical heat flux in narrow rectangular channels using an artificial neural network
International Nuclear Information System (INIS)
Zhou Lei; Yan Xiao; Huang Yanping; Xiao Zejun; Yu Jiyang
2011-01-01
The concept of Critical heat flux (CHF) and its importance are introduced and the meaning to research CHF in narrow rectangular channels independently is emphasized. This paper is the first effort to predict CHF in NRCs using aritificial neural network. The mathematical structure of the artificial neural network and the error back-propagation algorithm are introduced. To predict CHF, the four dimensionless groups are inputted to the neural network and the output is the dimensionless CHF. As the hidden nodes increased, the training error decreases while the testing error decreases firstly and then transition occurs. Based on this, the hidden nodes are set as 5 and the trained network predicts all of the training and testing data points with RMS=0.0016 and μ=1.0003, which is better than several well-known existing correlations. Based on the trained network, the effect of several parameters on CHF are simulated and discussed. CHF increases almost linearly as the inlet subcooling increases. And larger mass flux enhances the effect of the inlet subcooling. CHF increases with the mass flux increasing. And the effect seems to be a little stronger for relatively low system pressure. CHF decreases almost linearly as the system pressure increases for the fixed inlet condition. The slope of the curve also increases with higher mass flux. This observation is limited to the ranges of the experimental database. CHF decreases as the heated length is increased and the gradients of the curves become very sharp for relatively short channel. CHF increases slightly with the diameter increasing with the variance of the gap limited within 1 to 3 mm. For relatively low mass flux, the effect of the equivalent diameter on CHF is insignificant. As the width of the channel is large enough, the effect of the gap is quite the same as that of the equivalent diameter. A BPNN is successfully trained based on near 500 CHF data points in NRCs, which has much better performances than the
2013-01-01
Do you have last-minute gifts to get? Stuck for ideas? The CERN Shop and the ATLAS and CMS secretariats have some wonderfully unique gifts and stocking-fillers for sale this year - perfect for the physics fanatics in your life. Let's take a look... 1. CERN Notebook, 10 CHF - 2. CERN Pop-up book, 30 CHF - 3. USB Stick 8GB, 25 CHF - 4. CERN Tumbler, 12 CHF 5. ATLAS 3D Viewer, 5 CHF - 6. ATLAS Puzzle, 15 CHF - 7. CMS Umbrella, 25 CHF These gifts are all available at the CERN Shop, with the exception of the ATLAS 3D Viewer and the CMS umbrella, which are only available from the respective secretariats. Don’t forget! If you’re from CERN, you still have time to take advantage of a 10% off discount at the CERN shop. Offer ends 20 December.
DEFF Research Database (Denmark)
Køber, L; Torp-Pedersen, C; Pedersen, O D
1996-01-01
or persistent. Wall motion index and CHF are correlated. Furthermore, there is an interaction between wall motion index and CHF. The prognostic importance of wall motion index depends on whether patients have CHF or not: the risk ratio associated with decreasing 1 wall motion index unit is 3.0 (2.6 to 3......Left ventricular (LV) systolic function and congestive heart failure (CHF) are important predictors of long-term mortality after acute myocardial infarction. The importance of transient CHF and the interaction of CHF and LV function on prognosis has not been studied in detail previously....... In the TRAndolapril Cardiac Evaluation Study, 6,676 consecutive patients with acute myocardial infarction 1 to 6 days earlier had LV systolic function quantified as wall motion index (echocardiography), which is closely correlated to LV ejection fraction. To study the interaction of CHF and wall motion index on long...
Critical heat flux in tubes and tight hexagonal rod lattices
International Nuclear Information System (INIS)
Erbacher, F.J.; Cheng Xu; Zeggel, W.
1994-01-01
The critical heat flux (CHF) in small-diameter tubes and in tight hexagonal 7-rod and 37-rod bundles was investigated in the KRISTA test facility, using Freon 12 as the working fluid. The measurements in tubes showed that the influence of the tube diameter on CHF cannot be described as suggested by earlier publications with sufficient accuracy. CHF in bundles is lower than in tubes under comparable conditions. The influence of spacers (grid spacers, wire wraps) on CHF was found to be governed by local steam qualities. A comparison of the test results with some CHF prediction methods showed that the look-up table method reproduces the test results in circular tubes most accurately. Combined with CHF look-up tables, subchannel analysis and Ahmad's fluid-to-fluid scaling law, Freon experiments have proven to be a suitable tool for CHF prediction in water-cooled rod bundles. (orig.) [de
EXPERIMENTAL AND THEORETICAL NMR STUDY OF 4-(1 ...
African Journals Online (AJOL)
Preferred Customer
density functional theory (GIAO/DFT) approach is widely used for various types of compounds [12-. 20]. DFT calculations are hardly expensive and provide accurate results for chemical shifts and coupling constant on systems such as large organic ...
Directory of Open Access Journals (Sweden)
Lilis Retnaningsih
2016-06-01
Full Text Available Pada penelitian ini telah dilakukan sintesis antara serbuk partikel nano TiO2 dan serbuk partikel nano ZnO menjadi pasta yang akan diaplikasikan sebagai elektroda pada dye-sensitized solar cell (DSSC. Elektroda pada DSSC ini bekerja berdasarkan adsorbsi foton oleh pewarna, elektron yang tereksitasi ditransfer ke TiO2/ZnO yang mempunyai perbandingan berbeda. Dimensi material partikel nano TiO2/ZnO sebagai elektroda sangat penting untuk menghasilkan efisiensi yang lebih tinggi pada DSSC. Sifat ini sangat dipengaruh oleh metoda pabrikasi elektroda TiO2/ZnO dan parameternya. Pada penelitian ini digunakan metoda doctor blade untuk pabrikasi DSSC dan larutan dyes (Z907 sebagai zat pewarna. Tujuan penelitian ini adalah untuk mengetahui pengaruh pencampuran serbuk TiO2 dan serbuk ZnO sebagai elektroda. Teknik pembuatan pasta TiO2/ZnO sebagai elektroda sangat penting untuk menghasilkan efisiensi tinggi pada DSSC. Teknik ini sangat terkait dengan material TiO2/ZnO, metoda pabrikasi, dan parameter pengukurannya. Dalam penelitian ini dibahas hasil karakterisasi XRD pada kedua serbuk TiO2 dan ZnO, hasil SEM pada pencampuran kedua material, hasil pengujian IPCE serta hasil pengukuran effisiensi pada pengujian I - V.
International Nuclear Information System (INIS)
Denten, J.G.; Ishii, M.
1988-11-01
A visual study of film boiling using still photographic and high- speed motion picture methods was carried out in order to analyze the post-CHF hydrodynamics for steady-state inlet pre-CHF two-phase flow regimes. Pre-CHF two-phase flow regimes were established by introducing Freon 113 liquid and nitrogen gas into a jet core injection nozzle. An idealized, post-CHF two-phase core initial flow geometry (cylindrical multiphase jet core surrounded by a coaxial annulus of gas) was established at the nozzle exit by introducing nitrogen gas into the annular gap between the jet nozzle two-phase effluent and the heated test section inlet. For the present study three basic post-CHF flow regimes have been observed: the rough wavy regime (inverted annular flow preliminary break down), the agitated regime (transition between inverted annular and dispersed droplet flow), and the dispersed ligament/droplet regime. For pre-CHF bubbly flow in the jet nozzle, the post-CHF flow (beginning from jet nozzle exit/heated test section inlet) consists of the rough wavy regime, followed by the agitated and then the dispersed ligament/droplet regime. In the same way, for pre-CHF slug flow in the jet core, the post-CHF flow is comprised of the agitated regime at the nozzle exit, followed by the dispersed regime. Pre-CHF annular jet core flow results in a small, depleted post-CHF agitated flow regime at the nozzle exit, immediately followed by the dispersed ligament/droplet regime. Observed post dryout hydrodynamic behavior is reported, with particular attention given to the transition flow pattern between inverted annular and dispersed droplet flow. 43 refs., 20 figs., 5 tabs
Hemodynamic and neurochemical determinates of renal function in chronic heart failure.
Gilbert, Cameron; Cherney, David Z I; Parker, Andrea B; Mak, Susanna; Floras, John S; Al-Hesayen, Abdul; Parker, John D
2016-01-15
Abnormal renal function is common in acute and chronic congestive heart failure (CHF) and is related to the severity of congestion. However, treatment of congestion often leads to worsening renal function. Our objective was to explore basal determinants of renal function and their response to hemodynamic interventions. Thirty-seven patients without CHF and 59 patients with chronic CHF (ejection fraction; 23 ± 8%) underwent right heart catheterization, measurements of glomerular filtration rate (GFR; inulin) and renal plasma flow (RPF; para-aminohippurate), and radiotracer estimates of renal sympathetic activity. A subset (26 without, 36 with CHF) underwent acute pharmacological intervention with dobutamine or nitroprusside. We explored the relationship between baseline and drug-induced hemodynamic changes and changes in renal function. In CHF, there was an inverse relationship among right atrial mean pressure (RAM) pressure, RPF, and GFR. By contrast, mean arterial pressure (MAP), cardiac index (CI), and measures of renal sympathetic activity were not significant predictors. In those with CHF there was also an inverse relationship among the drug-induced changes in RAM as well as pulmonary artery mean pressure and the change in GFR. Changes in MAP and CI did not predict the change in GFR in those with CHF. Baseline values and changes in RAM pressure did not correlate with GFR in those without CHF. In the CHF group there was a positive correlation between RAM pressure and renal sympathetic activity. There was also an inverse relationship among RAM pressure, GFR, and RPF in patients with chronic CHF. The observation that acute reductions in RAM pressure is associated with an increase in GFR in patients with CHF has important clinical implications. Copyright © 2016 the American Physiological Society.
IMPLEMENTASI METODE HISTOGRAM EQUALIZATION UNTUK MENINGKATKAN KUALITAS CITRA DIGITAL
Directory of Open Access Journals (Sweden)
Isa Akhlis
2012-02-01
Full Text Available Radiografi dapat digunakan untuk membantu mendiagnosis penyakit dalam bidang medis. Umumnya citra radiograf masih tampak kabur sehingga memerlukan pengolahan untuk menghilangkan atau mengurangi kekaburan tersebut. Tujuan penelitian ini adalah mendesain perangkat lunak untuk meningkatkan kualitas citra digital foto Roentgen yaitu dengan meningkatkan kontras citra tersebut. Salah satu metode untuk meningkatkan kontras citra digital adalah dengan menggunakan metode histogram equalization. Metoda tersebut membuat tingkat keabuan citra tersebar merata pada semua tingkat keabuan. Hasil penelitian menunjukkan bahwa metoda histogram equalization dapat digunakan untuk meningkatkan kontras citra. Hal ini dapat langsung dilihat pada layar monitor.  Kata kunci: citra radiograf, histogram equalization
International Nuclear Information System (INIS)
Moon, Sang Ki; Chang, Soon Heung
1994-01-01
A new method to predict the critical heat flux (CHF) is proposed, based on the fuzzy clustering and artificial neural network. The fuzzy clustering classifies the experimental CHF data into a few data clusters (data groups) according to the data characteristics. After classification of the experimental data, the characteristics of the resulting clusters are discussed with emphasis on the distribution of the experimental conditions and physical mechanism. The CHF data in each group are trained in an artificial neural network to predict the CHF. The artificial neural network adjusts the weight so as to minimize the prediction error within the corresponding cluster. Application of the proposed method to the KAIST CHF data bank shows good prediction capability of the CHF, better than other existing methods. ((orig.))
Energy Technology Data Exchange (ETDEWEB)
Monde, M.; Mitsutake, Y. [Saga University, Saga (Japan). Faculty of Science and Engineering
2000-02-25
An experiment has been carried out to elucidate the critical heat flux (CHF) of an open two-phase thermosyphon with a bottom heated chamber in which heat is absorbed by evaporation of liquid. Another objective is to enhance the CHF using a concentric-tube by which counter-current flow of vapor and liquid in the throat of the chamber can be controlled well. The CHF data are measured for the saturated liquid of R 113 at a different pressure and different configuration of concentric tubes. The CHF data without the inner tube are in good agreement with the existing correlation and analytical result. The CHF increases by as much as several times of the CHF without the inner tube with an increase in the inner tube diameter up to a certain diameter of the inner tube and then decreases continuously as the inner tube diameter approaches the outer tube diameter. The optimum diameter of inner tube exists at which the CHF is maximum. (author)
DEFF Research Database (Denmark)
Christensen, Heidi Marie; Kistorp, Caroline Michaela Nervil; Schou, Morten
2012-01-01
The prevalence of cardiac cachexia has previously been estimated to 8-42 %. However, novel treatment strategies for chronic heart failure (CHF) have improved and decreased morbidity and mortality. Therefore, we aimed to reassess the prevalence of cachexia in an outpatient CHF clinic...... and to characterize a CHF population with and without cachexia with respect to body composition and related biomarkers. From 2008 to 2011, we screened 238 optimally treated, non-diabetic CHF patients for cardiac cachexia, defined as unintentional non-oedematous weight loss of >5 % over ≥6 months. CHF patients (LVEF...... 45 % (n = 19). The groups were matched for age, sex, and kidney function. Body composition was assessed by dual energy X-ray absorptiometry. The prevalence of cachexia was 10.5 %. Abdominal fat ± SD (%) was reduced in cachectic CHF: 27.4 ± 10.0 versus 37.5 ± 10.6 % (CHF, no cachexia) and 40...
Critical heat flux of water in vertical round tubes at low-pressure and low-flow conditions
International Nuclear Information System (INIS)
Park, Jae-Wook; Kim, Hong-Chae; Beak, Won-Pil; Chang, Soon Heung
1997-01-01
A series of critical heat flux (CHF) tests have been performed to provide a reliable set of CHF data for water flow in vertical round tubes at low pressure and low flow (LPLF) conditions. The range of experimental conditions is as follows: diameter 8, 10 mm; heated length 0.5, 1 m; pressure 2-9 bar, mass flux 50-200 kg/m 2 s; inlet subcooling 350, 450 kJ/kg. The observed parametric trends are generally consistent with the previous understanding except for the effects of system pressure and tube diameter. The pressure effect is small but very complicated; existing CHF correlations do not represent this parametric trend properly. CHF increases with the increase in diameter at fixed exit conditions, contrary to the general understanding. The artificial neural networks are applied to the round tube CHF data base at LPLF (P = 110-1100 kPa, G = 0-500 kg/m 2 s) conditions. The trained backpropagation networks (BPNs) predict CHF better than any other CHF correlations. Parametric trends of CHF based on the BPN for fixed inlet conditions generally agree well with our experimental results. (author)
Suggestions for Christmas gifts.
Connie Potter; Markus Nordberg
Have you been working long hours lately? Stuck in meetings too long to make it in time before the shops close? No need to worry. The ATLAS secretariat has plenty of items that will make great Christmas gifts for friends and family. Here are some of the items in stock. Note that you can negotiate a good price for bulk order. ATLAS caps (new item), 12 chf ATLAS t-shirts designed by Alan Alda, 20 chf ATLAS fleece jackets in several sizes and colors, 30 chf grey or dark blue in men's sizes pale blue for women's sizes (limited quantity) red for children (limited quantity) ATLAS puzzles with 500 pieces made by the Ravensburger company 15 chf for 1 box (price is less when purchasing more boxes) 50 chf for 5 boxes or more can also be purchased in boxes of 24, ready to ship to your institute ATLAS 3-D viewers, 5 chf ATLAS DVD, 5 chf CERN playing cards, 2 chf Make sure to get several boxes of the ATLAS puzzle for Christmas gifts. Offer hours of entertainement to friends and family! We tak...
Bartlett, Yvonne K; Haywood, Annette; Bentley, Claire L; Parker, Jack; Hawley, Mark S; Mountain, Gail A; Mawson, Susan
2014-11-25
Technology has the potential to provide support for self-management to people with congestive heart failure (CHF). This paper describes the results of a realist evaluation of the SMART Personalised Self-Management System (PSMS) for CHF. The PSMS was used, at home, by seven people with CHF. Data describing system usage and usability as well as questionnaire and interview data were evaluated in terms of the context, mechanism and outcome hypotheses (CMOs) integral to realist evaluation. The CHF PSMS improved heart failure related knowledge in those with low levels of knowledge at baseline, through providing information and quizzes. Furthermore, participants perceived the self-regulatory aspects of the CHF PSMS as being useful in encouraging daily walking. The CMOs were revised to describe the context of use, and how this influences both the mechanisms and the outcomes. Participants with CHF engaged with the PSMS despite some technological problems. Some positive effects on knowledge were observed as well as the potential to assist with changing physical activity behaviour. Knowledge of CHF and physical activity behaviour change are important self-management targets for CHF, and this study provides evidence to direct the further development of a technology to support these targets.
A heuristic application of critical power ratio to pressurized water reactor core design
International Nuclear Information System (INIS)
Ahn, Seung Hoon; Jeun, Gyoo Dong
2002-01-01
The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR correlation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large
Fitness Club
2010-01-01
Nordic Walking Nordic Walking Outings/Sorties Nordic Walking Mondays/Les lundis (1 hour/heure) RDV 12.20 parking des baraques, départ/departure 12.30 les 3, 10, 17 et 31 mai les 7, 14, 21 et 28 juin Saturdays/Les samedis (2 hours/heures) RDV 13.30 Mont Mourex, départ/departure 14.00 1er et 22 mai Nordic Walking Classes/Cours Nordic Walking Thursdays/Les jeudis (1 hour/heure) RDV 12.20 parking des baraques, depart/departure 12.30 Session 2 = 29.04, 06.05, 20.05, 27.05 Session 3 = 10.06, 17.06, 24.06, 01.07 Saturdays/les samedis cours (2 hours/heures) Session 4 = 08.05. + 15.05. Session 5 = 05.06. + 12.06. Prix Nordic walking outings/Les sorties nordic walking: 15 chf for 5 outings of 1 hour + 10 chf club membership 15 chf pour 5 sorties de 1 heure + 10 chf pour l’adhésion club. Nordic Walking Classes/Cours 1 session 40 chf + 10 chf pour l’adhésion club. 1 session 40 chf + 10 chf club membership Subscr...
International Nuclear Information System (INIS)
Weihsiao Ho; Kuanchywan Tu; Baushei Pei; Chinjang Chang
1993-01-01
The critical heat flux (CHF) is the maximum heat flux just before a boiling crisis; its importance as a measurement of nuclear reactor power capability design as well as in the safety of reactors has been recognized. With emphasis on CHF behavior under subcooled and low-quality (i.e., 2 ·s), an improved model that uses the sublayer dry out theory has been developed. Based on experimental observations of CHF, the model assumes that CHF under such conditions is of the departure from nucleate boiling type. Based on the postulation that CHF is triggered by Helmholtz instability in the sublayer steam-liquid system, the model was developed by a simple energy balance of liquid sublayer evaporation as the vapor blanket tends to disturb the balance between the buoyancy force and the drag force exerted upon it. The model is compared with the well-known Biasi et al. correlation as well as the Atomic Energy of Canada Limited lookup table against 102 uniformly heated round tube CHF data and 34 nonuniformly heated round tube CHF data. The comparison shows that the model provides better accuracy and a reasonable agreement between the predicted values and experimental CHF data
Vyshedskiy, Andrey; Ishikawa, Sadamu; Murphy, Raymond L H
2011-06-01
To determine the variability of crackle pitch and crackle rate during a single automated-auscultation session with a computerized 16-channel lung-sound analyzer. Forty-nine patients with pneumonia, 52 with congestive heart failure (CHF), and 18 with interstitial pulmonary fibrosis (IPF) performed breathing maneuvers in the following sequence: normal breathing, deep breathing, cough several times; deep breathing, vital-capacity maneuver, and deep breathing. From the auscultation recordings we measured the crackle pitch and crackle rate. Crackle pitch variability, expressed as a percentage of the average crackle pitch, was small in all patients and in all maneuvers: pneumonia 11%, CHF 11%, pulmonary fibrosis 7%. Crackle rate variability was also small: pneumonia 31%, CHF 32%, IPF 24%. Compared to the first deep-breathing maneuver (100%), the average crackle pitch did not significantly change following coughing (pneumonia 100%, CHF 103%, IPF 100%), the vital-capacity maneuver (pneumonia 100%, CHF 92%, IPF 104%), or during quiet breathing (pneumonia 97%, CHF 100%, IPF 104%). Similarly, the average crackle rate did not change significantly following coughing (pneumonia 105%, CHF 110%, IPF 90%) or the vital-capacity maneuver (pneumonia 102%, CHF 101%, IPF 99%). However, during normal breathing the crackle rate was significantly lower in the patients with pneumonia (74%, P auscultation session suggests that crackle rate can be used to follow the course of cardiopulmonary illnesses such as pneumonia, IPF, and CHF.
Urinary Proteolytic Activation of Renal Epithelial Na+ Channels in Chronic Heart Failure.
Zheng, Hong; Liu, Xuefei; Sharma, Neeru M; Li, Yulong; Pliquett, Rainer U; Patel, Kaushik P
2016-01-01
One of the key mechanisms involved in renal Na(+) retention in chronic heart failure (CHF) is activation of epithelial Na(+) channels (ENaC) in collecting tubules. Proteolytic cleavage has an important role in activating ENaC. We hypothesized that enhanced levels of proteases in renal tubular fluid activate ENaC, resulting in renal Na(+) retention in rats with CHF. CHF was produced by left coronary artery ligation in rats. By immunoblotting, we found that several urinary serine proteases were significantly increased in CHF rats compared with sham rats (fold increases: furin 6.7, prostasin 23.6, plasminogen 2.06, and plasmin 3.57 versus sham). Similar increases were observed in urinary samples from patients with CHF. Whole-cell patch clamp was conducted in cultured renal collecting duct M-1 cells to record Na(+) currents. Protease-rich urine (from rats and patients with CHF) significantly increased the Na(+) inward current in M-1 cells. Two weeks of protease inhibitor treatment significantly abrogated the enhanced diuretic and natriuretic responses to ENaC inhibitor benzamil in rats with CHF. Increased podocyte lesions were observed in the kidneys of rats with CHF by transmission electron microscopy. Consistent with these results, podocyte damage markers desmin and podocin expressions were also increased in rats with CHF (increased ≈2-folds). These findings suggest that podocyte damage may lead to increased proteases in the tubular fluid, which in turn contributes to the enhanced renal ENaC activity, providing a novel mechanistic insight for Na(+) retention commonly observed in CHF. © 2015 American Heart Association, Inc.
Urinary proteolytic activation of renal epithelial Na+ channels in chronic heart failure
Zheng, Hong; Liu, Xuefei; Sharma, Neeru M.; Li, Yulong; Pliquett, Rainer U; Patel, Kaushik P.
2015-01-01
One of the key mechanisms involved in renal Na+ retention in chronic heart failure (CHF) is activation of epithelial Na+ channels (ENaC) in collecting tubules. Proteolytic cleavage has an important role in activating ENaC. We hypothesized that enhanced levels of proteases in renal tubular fluid activate ENaC resulting in renal Na+ retention in rats with CHF. CHF was produced by left coronary artery ligation in rats. By immunoblotting, we found that several urinary serine proteases were significantly increased in CHF rats compared to sham rats (fold increases: furin 6.7, prostasin 23.6, plasminogen 2.06 and plasmin 3.57 vs. sham). Similar increases were observed in urinary samples from patients with CHF. Whole-cell patch-clamp was conducted in cultured renal collecting duct M-1 cells to record Na+ currents. Protease-rich urine (from rats and patients with CHF) significantly increased the Na+ inward current in M-1 cells. Two weeks of protease inhibitor treatment significantly abrogated the enhanced diuretic and natriuretic responses to ENaC inhibitor benzamil in rats with CHF. Increased podocyte lesions were observed in the kidneys of rats with CHF by transmission electron microscopy. Consistent with these results, podocyte damage markers desmin and podocin expressions were also increased in rats with CHF (increased ~2 folds). These findings suggest that podocyte damage may lead to increased proteases in the tubular fluid which in turn contributes to the enhanced renal ENaC activity, providing a novel mechanistic insight for Na+ retention commonly observed in CHF. PMID:26628676
Staff Association
2012-01-01
SPECIAL OFFER FOR OUR MEMBERS Prices Spring and Summer 2012 Half-day ticket: 5 hours, same price weekends, public holidays and weekdays. Children from 5 to 15 years old: 26 CHF instead of 35 CHF Adults from 16 years old: 32 CHF instead of 43 CHF Bonus! Free for children under 5. Aquaparc Les Caraïbes sur Léman 1807 Le Bouveret (VS)
Prediction of Critical Heat Flux under Rolling Motion
Energy Technology Data Exchange (ETDEWEB)
Hwang, Jinseok; Lee, Yeongun; Park, Gooncherl [Seoul National Univ., Seoul (Korea, Republic of)
2013-05-15
The aim to this paper may be summarized as follows: identify the flow regime compare with existing void-quality relationship and void fraction at OAF derived from the vapor superficial velocity obtained by the churn-to annular flow criterion, develop and evaluate the correlation for accurate prediction of CHF ratio under rolling motion. Experimentally measured CHF results from the previous study were not well-predicted by existing CHF correlations developed for wide range of pressure under rolling motion in vertical tube. Specifically, existing correlations do not account for the dynamic motion parameter, such as tangential and centrifugal force. This study reviewed some existing correlation and experimental studies related to reduction and enhancement of CHF and heat transfer and flow behavior under heaving and rolling motion, and developed a CHF ratio correlation for upward flow vertical tube under rolling motion. Based upon dimensionless groups, equations and interpolation factor, an empirical CHF correlation has been developed which is consistent with experimental data for uniformly heated tubes internally cooled by R-134 under rolling motion. Flow regime was determined through the prediction method for annular flow. Non-dimensional number and function were decided by CHF mechanism of each region. Interaction of LFD and DNB regions is taken into account by means of power interpolation which is reflected void fraction at OAF. The suggested correlation predicted the CHF Ratio with reasonable accuracy, showing an average error of -0.59 and 2.51% for RMS. Rolling motion can affect bubble motion and liquid film behavior complexly by combination of tangential and centrifugal forces and mass flow than heaving motion. Through a search of literature and a comparison of previous CHF ratio results, this work can contribute to the study of boiling heat transfer and CHF for the purpose of enhancement or reduction the CHF of dynamic motion system, such as marine reactor.
Improvement of critical heat flux correlation for research reactors using plate-type fuel
International Nuclear Information System (INIS)
Kaminaga, Masanori; Yamamoto, Kazuyoshi; Sudo, Yukio
1998-01-01
In research reactors, plate-type fuel elements are generally adopted so as to produce high power densities and are cooled by a downward flow. A core flow reversal from a steady-state forced downward flow to an upward flow due to natural convection should occur during operational transients such as Loss of the primary coolant flow'. Therefore, in the thermal hydraulic design of research reactors, critical heat flux (CHF) under a counter-current flow limitation (CCFL) or a flooding condition are important to determine safety margins of fuel against CHF during a core flow reversal. The authors have proposed a CHF correlation scheme for the thermal hydraulic design of research reactors, based on CHF experiments for both upward and downward flows including CCFL condition. When the CHF correlation scheme was proposed, a subcooling effect for CHF correlation under CCFL condition had not been considered because of a conservative evaluation and a lack of enough CHF data to determine the subcooling effect on CHF. A too conservative evaluation is not appropriate for the design of research reactors because of construction costs etc. Also, conservativeness of the design must be determined precisely. In this study, therefore, the subcooling effect on CHF under the CCFL conditions in vertical rectangular channels heated from both sides were investigated quantitatively based on CHF experimental results obtained under uniform and non-uniform heat flux conditions. As a result, it was made clear that CHF in this region increase linearly with an increase of the channel inlet subcooling and a new CHF correlation including the effect of channel inlet subcooling was proposed. The new correlation could be adopted under the conditions of the atmospheric pressure, the inlet subcooling less than 78K, the channel gap size between 2.25 to 5.0mm, the axial peaking factor between 1.0 to 1.6 and L/De between 71 to 174 which were the ranges investigated in this study. (author)
International Nuclear Information System (INIS)
Lee, Yong Bum
1994-02-01
The critical heat flux (CHF) phenomenon in the two-phase convective flows has been an important issue in the fields of design and safety analysis of light water reactor (LWR) as well as sodium cooled liquid metal fast breeder reactor (LMFBR). Especially in the LWR application many physical aspects of the CHF phenomenon are understood and reliable correlations and mechanistic models to predict the CHF condition have been proposed. However, there are few correlations and models which are applicable to liquid metals. Compared with water, liquid metals show a divergent picture for boiling pattern. Therefore, the CHF conditions obtained from investigations with water cannot be applied to liquid metals. In this work a mechanistic model to predict the CHF of water and a correlation for liquid metals are developed. First, a mechanistic model to predict the CHF in flow boiling at low quality was developed based on the liquid sublayer dryout mechanism. In this approach the CHF is assumed to occur when a vapor blanket isolates the liquid sublayer from bulk liquid and then the liquid entering the sublayer falls short of balancing the rate of sublayer dryout by vaporization. Therefore, the vapor blanket velocity is the key parameter. In this work the vapor blanket velocity is theoretically determined based on mass, energy, and momentum balance and finally the mechanistic model to predict the CHF in flow boiling at low quality is developed. The accuracy of the present model is evaluated by comparing model predictions with the experimental data and tabular data of look-up tables. The predictions of the present model agree well with extensive CHF data. In the latter part a correlation to predict the CHF for liquid metals is developed based on the flow excursion mechanism. By using Baroczy two-phase frictional pressure drop correlation and Ledinegg instability criterion, the relationship between the CHF of liquid metals and the principal parameters is derived and finally the
Chlorophyll fluorescence response to water and nitrogen deficit
Cendrero Mateo, Maria del Pilar
The increasing food demand as well as the need to predict the impact of warming climate on vegetation makes it critical to find the best tools to assess crop production and carbon dioxide (CO2) exchange between the land and atmosphere. Photosynthesis is a good indicator of crop production and CO2 exchange. Chlorophyll fluorescence (ChF) is directly related to photosynthesis. ChF can be measured at leaf-scale using active techniques and at field-scales using passive techniques. The measurement principles of both techniques are different. In this study, three overarching questions about ChF were addressed: Q1) How water, nutrient and ambient light conditions determine the relationships between photosynthesis and ChF? Which is the optimum irradiance level for detecting water and nutrient deficit conditions with ChF? ; Q2) which are the limits within which active and passive techniques are comparable?; and Q3) What is the seasonal relationship between photosynthesis and ChF when nitrogen is the limiting factor? To address these questions, two main experiments were conducted: Exp1) Concurrent photosynthesis and ChF light-response curves were measured in camelina and wheat plants growing under (i) intermediate-light and (ii) high-light conditions respectively. Plant stress was induced by (i) withdrawing water, and (ii) applying different nitrogen levels; and Exp2) coincident active and passive ChF measurements were made in a wheat field under different nitrogen treatments. The results indicated ChF has a direct relationship with photosynthesis when water or nitrogen drives the relationship. This study demonstrates that the light level at which plants were grown was optimum for detecting water and nutrient deficit with ChF. Also, the results showed that for leaf-average-values, active measurements can be used to better understand the daily and seasonal behavior of passive ChF. Further, the seasonal relation between photosynthesis and ChF with nitrogen stress was not a
Caldentey, Guillem; Khairy, Paul; Roy, Denis; Leduc, Hugues; Talajic, Mario; Racine, Normand; White, Michel; O'Meara, Eileen; Guertin, Marie-Claude; Rouleau, Jean L; Ducharme, Anique
2014-02-01
This study sought to assess the prognostic value of physical examination in a modern treated heart failure population. The physical examination is the cornerstone of the evaluation and monitoring of patients with heart failure. Yet, the prognostic value of congestive signs (i.e., peripheral edema, jugular venous distension, a third heart sound, and pulmonary rales) has not been assessed in the current era. A post-hoc analysis was conducted on all 1,376 patients, 81% male, mean age 67 ± 11 years, with symptomatic left ventricular systolic dysfunction enrolled in the AF-CHF (Atrial Fibrillation and Congestive Heart Failure) trial. The prognostic value of baseline physical examination findings was assessed in univariate and multivariate Cox regression analyses. Peripheral edema was observed in 425 (30.9%), jugular venous distension in 297 (21.6%), a third heart sound in 207 (15.0%), and pulmonary rales in 178 (12.9%) patients. Death from cardiovascular causes occurred in 357 (25.9%) patients over a mean follow-up of 37 ± 19 months. All 4 physical examination findings were associated with cardiovascular mortality in univariate analyses (all p values examination (i.e., peripheral edema, jugular venous distension, a third heart sound, and pulmonary rales) continue to provide important prognostic information in patients with congestive heart failure. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Assessment of ASSERT-PV for prediction of critical heat flux in CANDU bundles
International Nuclear Information System (INIS)
Rao, Y.F.; Cheng, Z.; Waddington, G.M.
2014-01-01
Highlights: • Assessment of the new Canadian subchannel code ASSERT-PV 3.2 for CHF prediction. • CANDU 28-, 37- and 43-element bundle CHF experiments. • Prediction improvement of ASSERT-PV 3.2 over previous code versions. • Sensitivity study of the effect of CHF model options. - Abstract: Atomic Energy of Canada Limited (AECL) has developed the subchannel thermalhydraulics code ASSERT-PV for the Canadian nuclear industry. The recently released ASSERT-PV 3.2 provides enhanced models for improved predictions of flow distribution, critical heat flux (CHF), and post-dryout (PDO) heat transfer in horizontal CANDU fuel channels. This paper presents results of an assessment of the new code version against five full-scale CANDU bundle experiments conducted in 1990s and in 2009 by Stern Laboratories (SL), using 28-, 37- and 43-element (CANFLEX) bundles. A total of 15 CHF test series with varying pressure-tube creep and/or bearing-pad height were analyzed. The SL experiments encompassed the bundle geometries and range of flow conditions for the intended ASSERT-PV applications for CANDU reactors. Code predictions of channel dryout power and axial and radial CHF locations were compared against measurements from the SL CHF tests to quantify the code prediction accuracy. The prediction statistics using the recommended model set of ASSERT-PV 3.2 were compared to those from previous code versions. Furthermore, the sensitivity studies evaluated the contribution of each CHF model change or enhancement to the improvement in CHF prediction. Overall, the assessment demonstrated significant improvement in prediction of channel dryout power and axial and radial CHF locations in horizontal fuel channels containing CANDU bundles
Zhang, Dongze; Liu, Jinxu; Zheng, Hong; Tu, Huiyin; Muelleman, Robert L; Li, Yu-Long
2015-07-01
Impairment of arterial baroreflex sensitivity is associated with mortality in patients with chronic heart failure (CHF). Elevation of plasma angiotension II (Ang II) contributes to arterial baroreflex dysfunction in CHF. A reduced number of voltage-gated sodium (Nav) channels in aortic baroreceptor neurons are involved in CHF-blunted arterial baroreflex. In this study, we investigated acute effect of Ang II on Nav currents in the aortic baroreceptor neuron and on arterial baroreflex in sham and coronary artery ligation-induced CHF rats. Using Ang II I radioimmunoassay, real-time reverse transcription-PCR and western blot, we found that Ang II levels, and mRNA and protein expression of angiotension II type 1 receptor in nodose ganglia from CHF rats were higher than that from sham rats. Local microinjection of Ang II (0.2 nmol) into the nodose ganglia decreased the arterial baroreflex sensitivity in sham rats, whereas losartan (1 nmol, an angiotension II type 1 receptor antagonist) improved the arterial baroreflex sensitivity in CHF rats. Data from patch-clamp recording showed that Ang II (100 nmol/l) acutely inhibited Nav currents in the aortic baroreceptor neurons from sham and CHF rats. In particular, inhibitory effect of Ang II on Nav currents in the aortic baroreceptor neurons was larger in CHF rats than that in sham rats. Losartan (1 μmol/l) totally abolished the inhibitory effect of Ang II on Nav currents in sham and CHF aortic baroreceptor neurons. These results suggest that elevation of endogenous Ang II in the nodose ganglia contributes to impairment of the arterial baroreflex function in CHF rats through inhibiting Nav channels.
International Nuclear Information System (INIS)
Lee, Kwang-Won; Yang, Jae-Young; Baik, Se-Jin
1997-01-01
Based on several experimental evidences for nucleate boiling in annular film and the existence of residual liquid film flow rate at the critical heat flux (CHF) location, the liquid sublayer dryout (LSD) mechanism under annular film is firstly introduced to evaluate the CHF data at low pressure and low velocity (LPLV) conditions, which would not be predicted by a normal annular film dryout (AFD) model. In this study, the CHF occurrence due to annular film separation or breaking down is phenomenologically modelled by applying the LSD mechanism to this situation. In this LSD mechanism, the liquid sublayer thickness, the incoming liquid velocity to the liquid sublayer, and the axial distance from the onset of annular flow to the CHF location are used as the phenomena-controlling parameters. From the model validation on the 1406 CHF data points ranging over P = 0.1 - 2 MPa, G = 4 - 499 kg/m 2 s, L/D = 4 - 402, most of CHF data (more than 1000 points) are predicted within ±30% error bounds by the LSD mechanism. However, some calculation results that critical qualities are less than 0.4 are considerably overestimated by this mechanism. These overpredictions seem to be caused by inadequate CHF mechanism classification criteria and an insufficient consideration of the flow instability effect on CHF. Further studies for a new classification criterion screening the CHF data affected by flow instabilities and a new bubble detachment model for LPLV conditions are needed to improve the model accuracy. (author)
International Nuclear Information System (INIS)
Vishnoi, A.K.; Dasgupta, A.; Chandraker, D.K.; Nayak, A.K.; Vijayan, P.K.
2015-01-01
Two-phase natural circulation loops have extensive applications in nuclear and process industries. One of the major concerns with natural circulation is the occurrence of the various types of flow instabilities, which can cause premature boiling crisis due to flow and power oscillations. In this work a transient computer code COPCOS (Code for Prediction of CHF under Oscillating flow and power condition) has been developed to predict the premature occurrence of CHF (critical heat flux) under oscillating flow and power. The code incorporates conduction equation of the fuel and coolant energy equation. For CHF prediction, CHF look-up table developed by Groeneveld is used. A facility named CHF and Instability Loop (CHIL) has been set up to study the effect of oscillatory flow on CHF. CHF and Instability Loop (CHIL) is a simple rectangular loop having a 10.5 mm ID and 1.2 m long test section. The flow through the test section is controlled by a canned motor pump using a Variable Frequency Drive (VFD). This leads to the ability of having a very precise control over flow oscillations which can be induced in the test section. The effect of frequency and amplitude of flow oscillation on occurrence of premature CHF has been investigated in this facility using COPCOS. Full paper covers details of COPCOS code, description of the facility and effect of frequency and the effect of oscillatory flow on CHF in the facility. (author)
The Sensitivity Analysis of Axial Pressure Tube Creep Profile for Dryout Power in PHWR
Energy Technology Data Exchange (ETDEWEB)
Ryu, Euiseung; Kim, Youngae [KHNP CRI, Daejeon (Korea, Republic of)
2016-10-15
The Stern Laboratory performed the CHF tests with only one axial pressure tube creep profile per 3.3%, 5.1% peak crept channel and made CHF correlation including creep factor from the CHF test results. Wolsong nuclear power plants also have utilized the same CHF correlation derived by CNL. Pressure tube diameter creep rate is function of fast neutron, coolant temperature, and coolant pressure in a channel. It means that various axial pressure tube creep profiles exist in PHWR due to the history of operating conditions. Usually, CHF correlation is used during ROP(Regional Overpower Protection) Trip Setpoint Analysis or Safety Analysis in PHWR. The sensitivity analysis for CHF effects using various creep profiles is needed. This paper summarizes the comparison results of dryout power between CHF test creep profile and estimated creep profiles of Wolsong units. The effect of axial pressure tube creep profile for dryout power in fuel channel is evaluated by using Stern Lab. CHF test creep profile and 380 channel creep profiles of Wolsong. The dryout powers at 3.3% and 5.1% test conditions are slightly smaller when using 380 Wolsong channels creep profiles. These also show that the simulated dryout powers maintain consistency regardless of flow conditions.
Niewinski, Piotr; Engelman, Zoar J; Fudim, Marat; Tubek, Stanislaw; Paleczny, Bartlomiej; Jankowska, Ewa A; Banasiak, Waldemar; Sobotka, Paul A; Ponikowski, Piotr
2013-06-01
Augmented peripheral chemoreflex response is an important mechanism in the pathophysiology of chronic heart failure (CHF). This study characterizes prevalence and clinical predictors of this phenomenon in optimally managed male CHF patients, and seeks to describe the hemodynamic consequences of chemoreceptor hypersensitivity. Thirty-four optimally managed CHF patients and 16 control subjects were prospectively studied. Hypoxic ventilatory response (HVR)-a measure of peripheral chemosensitivity-was calculated with the use of short nitrogen gas administrations. Systolic blood pressure (SBP) and heart rate (HR) following transient hypoxic challenges were recorded with a Nexfin monitor. Hemodynamic responses to hypoxia were expressed by the linear slopes between oxygen saturation (%) and SBP (mm Hg) or HR (beats/min). Elevated HVR was present in 15 (44%) of the CHF patients. Patients with elevated HVR exhibited higher levels of N-terminal pro-B-type natriuretic peptide, lower left ventricular ejection fraction, and higher prevalence of atrial fibrillation. CHF patients with elevated HVR had significantly greater SBP and HR responses to hypoxia than CHF patients with normal HVR. Despite comprehensive pharmacotherapy, elevated HVR is prevalent in CHF patients, related to severity of the disease and associated with augmented hemodynamic responses to hypoxia. CHF patients with elevated HVR may be prone to unfavorable hemodynamic changes. Copyright © 2013 Elsevier Inc. All rights reserved.
Development of low flow critical heat flux correlation for HANARO
International Nuclear Information System (INIS)
Park, Cheol; Chae, Hee Taek; Hang, Gee Yang.
1997-07-01
A low flow CHF correlation was developed for the safe operation of HANARO during the natural circulation cooling and the assessment of safety during the low flow condition of accident. The analytical model was applied to estimate the heat flux and the temperature distributions along the periphery of the fin at CHF conditions, and the predicted wall temperature at the sheath between the fins by the model agreed well with the measured one. The parametric trends of the CHF data for the finned geometry agreed with the general understanding from the previous studies for the unfinned annulus or tube geometries. It is revealed that the fin does not affect the CHF for low flow condition, although it increase the critical power due to larger heat transfer area. As the existing CHF correlation is proposed to predict the CHF for both finned and unfinned geometries at low flow and low pressure conditions. The developed correlation predicts the experimental CHF data with RMS errors of 13.7 %. (author). 19 refs., 3 tabs., 23 figs
Development of low flow critical heat flux correlation for HANARO
Energy Technology Data Exchange (ETDEWEB)
Park, Cheol; Chae, Hee Taek; Hang, Gee Yang
1997-07-01
A low flow CHF correlation was developed for the safe operation of HANARO during the natural circulation cooling and the assessment of safety during the low flow condition of accident. The analytical model was applied to estimate the heat flux and the temperature distributions along the periphery of the fin at CHF conditions, and the predicted wall temperature at the sheath between the fins by the model agreed well with the measured one. The parametric trends of the CHF data for the finned geometry agreed with the general understanding from the previous studies for the unfinned annulus or tube geometries. It is revealed that the fin does not affect the CHF for low flow condition, although it increase the critical power due to larger heat transfer area. As the existing CHF correlation is proposed to predict the CHF for both finned and unfinned geometries at low flow and low pressure conditions. The developed correlation predicts the experimental CHF data with RMS errors of 13.7 %. (author). 19 refs., 3 tabs., 23 figs.
International Nuclear Information System (INIS)
Vaziri, Nima; Hojabri, Alireza; Erfani, Ali; Monsefi, Mehrdad; Nilforooshan, Behnam
2007-01-01
Critical heat flux (CHF) is an important parameter for the design of nuclear reactors. Although many experimental and theoretical researches have been performed, there is not a single correlation to predict CHF because it is influenced by many parameters. These parameters are based on fixed inlet, local and fixed outlet conditions. Artificial neural networks (ANNs) have been applied to a wide variety of different areas such as prediction, approximation, modeling and classification. In this study, two types of neural networks, radial basis function (RBF) and multilayer perceptron (MLP), are trained with the experimental CHF data and their performances are compared. RBF predicts CHF with root mean square (RMS) errors of 0.24%, 7.9%, 0.16% and MLP predicts CHF with RMS errors of 1.29%, 8.31% and 2.71%, in fixed inlet conditions, local conditions and fixed outlet conditions, respectively. The results show that neural networks with RBF structure have superior performance in CHF data prediction over MLP neural networks. The parametric trends of CHF obtained by the trained ANNs are also evaluated and results reported
Supplementary contribution payable to the Health Insurance Scheme for spouses
HR Department
2008-01-01
Staff members, fellows and pensioners are reminded that any change in their marital status, as well as any change in their spouse or registered partner’s income or health insurance cover, must be reported to CERN in writing within 30 calendar days, in accordance with Articles III 6.01 to 6.03 of the Rules of the CERN Health Insurance Scheme (CHIS). Such changes may affect the conditions of the spouse or registered partner’s membership of the CHIS or the payment of the supplementary contribution to it for the spouse or registered partner’s insurance cover. For more information see: http://cern.ch/chis/contribsupp.asp From 1.1.2008, the indexed amounts of the supplementary monthly contribution for the different monthly income brackets are as follows, expressed in Swiss francs: more than 2500 CHF and up to 4250 CHF: 134.- more than 4250 CHF and up to 7500 CHF: 234.- more than 7500 CHF and up to 10,000 CHF: 369.- more than 10,000 CHF: 470.- It is in the member of the ...
CHRONIC HEART FAILURE AND IRON-DEFICIENT ANEMIA
Directory of Open Access Journals (Sweden)
M. V. Melnik
2015-12-01
Full Text Available 62 chronic heart failure (CHF patients with iron-deficient anemia (IDA were studied. Standard CHF therapy (angiotensin converting enzyme inhibitors, β-blockers, diuretics, cardiac glycosides was accompanied with the correction of iron deficiency by intravenous injection of Venofer and subsequent Ferro-Folgamma prescription (average daily dose of iron 137,75±5mg. After treatment serum iron level increased by 95,5% and hemoglobin level – by 9,8%. Left ventricular ejection fraction increased by 32,2% and physical activity tolerance – by 47,6%. Before treatment 32 CHF patients with IDA (51,6% had III functional class (FC of CHF according to NYHA and 16 patients (25,8% – IV FC. After treatment I FC was observed in 18 CHF patients (29%, II FC – in 26 patients and only 18 patients demonstrated III FC of CHF.
CHRONIC HEART FAILURE AND IRON-DEFICIENT ANEMIA
Directory of Open Access Journals (Sweden)
M. V. Melnik
2007-01-01
Full Text Available 62 chronic heart failure (CHF patients with iron-deficient anemia (IDA were studied. Standard CHF therapy (angiotensin converting enzyme inhibitors, β-blockers, diuretics, cardiac glycosides was accompanied with the correction of iron deficiency by intravenous injection of Venofer and subsequent Ferro-Folgamma prescription (average daily dose of iron 137,75±5mg. After treatment serum iron level increased by 95,5% and hemoglobin level – by 9,8%. Left ventricular ejection fraction increased by 32,2% and physical activity tolerance – by 47,6%. Before treatment 32 CHF patients with IDA (51,6% had III functional class (FC of CHF according to NYHA and 16 patients (25,8% – IV FC. After treatment I FC was observed in 18 CHF patients (29%, II FC – in 26 patients and only 18 patients demonstrated III FC of CHF.
Validation of film dryout model in a three-fluid code FIDAS
International Nuclear Information System (INIS)
Sugawara, Satoru
1989-11-01
Analytical prediction model of critical heat flux (CHF) has been developed on the basis of film dryout criterion due to droplets deposition and entrainment in annular mist flow. CHF in round tubes were analyzed by the Film Dryout Analysis Code in Subchannels, FIDAS, which is based on the three-fluid, three-field and newly developed film dryout model. Predictions by FIDAS were compared with the world-wide experimental data on CHF obtained in water and Freon for uniformly and non-uniformly heated tubes under vertical upward flow condition. Furthermore, CHF prediction capability of FIDAS was compared with those of other film dryout models for annular flow and Katto's CHF correlation. The predictions of FIDAS are in sufficient agreement with the experimental CHF data, and indicate better agreement than the other film dryout models and empirical correlation of Katto. (author)
Analyses of bundle experiment data using MATRA-h
Energy Technology Data Exchange (ETDEWEB)
Lim, In Cheol; Chea, Hee Taek [Korea Atomic Energy Research Institute, Taejon (Korea)
1998-06-01
When the construction and operation license for HANARO was renewed in 1995, 25% of CHF penalty was imposed. The reason for this was that the validation work related to the CHF design calculation was not enough for the assurance of CHF margin. As a part of the works to recover this CHF penalty, MATRA-h was developed by implementing the new correlations for the heat transfer, CHF prediction, subcooled void to the MATRA-a, which is the modified version of COBRA-IV-I done by KAERI. Using MATRA-h, the subchannel analyses for the bundle experiment data were performed. The comparison of the code predictions with the experimental results, it was found that the code would give the conservative predictions as far as the CHF in the bundle geometry is concerned. (author). 12 refs., 25 figs., 16 tabs.
Development of local TDC model in core thermal hydraulic analysis
International Nuclear Information System (INIS)
Kwon, H.S.; Park, J.R.; Hwang, D.H.; Lee, S.K.
2004-01-01
The local TDC model consisting of natural mixing and forced mixing part was developed to obtain more realistic local fluid properties in the core subchannel analysis. To evaluate the performance of local TDC model, the CHF prediction capability was tested with the various CHF correlations and local fluid properties at CHF location which are based on the local TDC model. The results show that the standard deviation of measured to predicted CHF ratio (M/P) based on local TDC model can be reduced by about 7% compared to those based on global TDC model when the CHF correlation has no term to account for distance from the spacer grid. (author)
Metaiodobenzylguanidine and heart rate variability in heart failure
International Nuclear Information System (INIS)
Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko
1998-01-01
It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)
Metaiodobenzylguanidine and heart rate variability in heart failure
Energy Technology Data Exchange (ETDEWEB)
Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko
1998-10-01
It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)
A study on the critical heat flux for annuli and round tubes under low pressure conditions
International Nuclear Information System (INIS)
Park, Jae Wook
1997-02-01
This study aims to reveal the characteristics of the critical heat flux (CHF) of internally heated concentric annuli and vertical round tubes in low-pressure and low-flow (LPLF) conditions. Although many efforts have been devote to the subject of the CHF during the last forty years, the information on the CHF phenomenon for LPLF conditions is still very limited. The applicable ranges of the CHF correlations for annuli and round tubes are concentrate on the operating conditions of nuclear power plant (NPP), namely high-pressure and high-flow (HPHF) conditions. these facts promoted to collect the reliable CHF data for LPLF conditions for both annuli and round tubes. The critical heat flux data for vertical flow boiling of water in annuli and round tubes at low pressures and low mass fluxes show the following trends: The observed CHF mechanism for annuli was changed in the order of flooding, churn-to-annular flow transition, and local dryout under a large bubble in churn flow as the flow rate was increased from zero to higher values. The observed parametric trends for annuli are consistent with the previous understanding except that the CHF for downward flow is considerably lower (up to 40%) than that for upward flow. The critical quality is much lower than that for round tubes at the same inlet conditions. The observed parametric trends for round tubes are generally consistent with the previous understanding except for system pressure an tube diameter effect. For the system pressure effect, it is observed that the pressure effect is complicated but not so large, whereas the existing CHF correlations do not present the parametric trend exactly. For tube diameter effect, the decreasing trends of CHF with respect to tube diameter was the general understanding so far, but in this region the CHF show a increasing trend of tube diameter. The prediction and the parametric trend analyses are performed by two view points, I.e., for fixed inlet conditions and for local
A study on the flow induced vibration in two phase flow under heating and non-heating conditions
International Nuclear Information System (INIS)
Kim, Dae Hun
2007-02-01
Critical heat flux (CHF) enhancement devices, like a spacer grid with mixing vane, cause flow-induced vibration (FIV) due to turbulence made by structural resistance. CHF enhancement and FIV reduction are usually studied separately. The main purpose of this article is to investigate the relationship between CHF and FIV. Information of flow-induced vibration due to wire coil design, is experimentally presented in this study by detecting flow-induced vibration under the two-phase flow condition with wire coil inserts. CHF experiments were performed in an upward vertical annulus tube under controlled vibration conditions to determine the effect of vibration on CHF. FIV was measured in an upward vertical tube with various wire coil inserts using air-water as flow material. CHF experiments were performed at one atmosphere with mechanically controlled vibration. A quartz tube (inner diameter of 17 mm, thickness of 2mm and length of 0.72 m) was used for outer tube and a SUS-304 tube (outer diameter of 6.35 mm, thickness of 0.89 mm and length of 0.7 m) was used for the inner heater. Vibration of the heater tube with an amplitude range of 0.1 mm to 0.5 mm and a frequency range of 10 Hz to 50 Hz was carried out at a mass flux of 115 kg/m 2 s and 215 kg/m 2 s. CHF was enhanced by vibration with a maximum ratio of 16.4 %. CHF was increased with increased amplitude and quality. The CHF correlation was developed with R (coefficient of correlation) of 0.903. FIV measuring experiments were performed at one atmosphere by changing the inserted wire coil type. An acrylic tube was used for the test section with inner diameter of 25 mm, thickness of 10 mm and length of 0.5 m. Four types of wire coil, which have a thickness of between 2 mm and 3 mm and pitch length of between 25 mm and 50 mm, were used. FIV and dynamic pressure were detected in water mass flux range of 100 ∼ 3060 kg/m 2 s and air mass flux range of 5.02 ∼ 60.3 kg/m 2 s. Vibration increased along with mass flux and
Flow regimes and mechanistic modeling of critical heat flux under subcooled flow boiling conditions
Le Corre, Jean-Marie
Thermal performance of heat flux controlled boiling heat exchangers are usually limited by the Critical Heat Flux (CHF) above which the heat transfer degrades quickly, possibly leading to heater overheating and destruction. In an effort to better understand the phenomena, a literature review of CHF experimental visualizations under subcooled flow boiling conditions was performed and systematically analyzed. Three major types of CHF flow regimes were identified (bubbly, vapor clot and slug flow regime) and a CHF flow regime map was developed, based on a dimensional analysis of the phenomena and available data. It was found that for similar geometric characteristics and pressure, a Weber number (We)/thermodynamic quality (x) map can be used to predict the CHF flow regime. Based on the experimental observations and the review of the available CHF mechanistic models under subcooled flow boiling conditions, hypothetical CHF mechanisms were selected for each CHF flow regime, all based on a concept of wall dry spot overheating, rewetting prevention and subsequent dry spot spreading. It is postulated that a high local wall superheat occurs locally in a dry area of the heated wall, due to a cyclical event inherent to the considered CHF two-phase flow regime, preventing rewetting (Leidenfrost effect). The selected modeling concept has the potential to span the CHF conditions from highly subcooled bubbly flow to early stage of annular flow. A numerical model using a two-dimensional transient thermal analysis of the heater undergoing nucleation was developed to mechanistically predict CHF in the case of a bubbly flow regime. In this type of CHF two-phase flow regime, the high local wall superheat occurs underneath a nucleating bubble at the time of bubble departure. The model simulates the spatial and temporal heater temperature variations during nucleation at the wall, accounting for the stochastic nature of the boiling phenomena. The model has also the potential to evaluate
Ryanodine Receptor Calcium Leak in Circulating B-Lymphocytes as a Biomarker in Heart Failure.
Kushnir, Alexander; Santulli, Gaetano; Reiken, Steven R; Coromilas, Ellie; Godfrey, Sarah J; Brunjes, Danielle L; Colombo, Paolo C; Yuzefpolskaya, Melana; Sokol, Seth I; Kitsis, Richard N; Marks, Andrew R
2018-03-28
Background -Advances in congestive heart failure (CHF) management depend on biomarkers for monitoring disease progression and therapeutic response. During systole, intracellular Ca2 + is released from the sarcoplasmic reticulum (SR) into the cytoplasm through type 2 ryanodine receptor/Ca2 + release channels (RyR2). In CHF, chronically elevated circulating catecholamine levels cause pathologic remodeling of RyR2 resulting in diastolic SR Ca2 + leak, and decreased myocardial contractility. Similarly, skeletal muscle contraction requires SR Ca2 + release through type-1 ryanodine receptors (RyR1), and chronically elevated catecholamine levels in CHF cause RyR1 mediated SR Ca2 + leak, contributing to myopathy and weakness. Circulating B-lymphocytes express RyR1 and catecholamine responsive signaling cascades, making them a potential surrogate for defects in intracellular Ca2 + handling due to leaky RyR channels in CHF. Methods -Whole blood was collected from patients with CHF, CHF status-post left-ventricular assist devices (LVAD), and controls. Blood was also collected from mice with ischemic CHF, ischemic CHF + S107 (a drug that specifically reduces RyR channel Ca2 + leak), and WT controls. Channel macromolecular complex was assessed by immunostaining RyR1 immunoprecipitated from lymphocyte enriched preparations. RyR1 Ca2 + leak was assessed using flow cytometry to measure Ca2 + fluorescence in B-lymphocytes, in the absence and presence of RyR1 agonists that empty RyR1 Ca2 + stores within the endoplasmic reticulum (ER). Results -Circulating B-lymphocytes from humans and mice with CHF exhibited remodeled RyR1 and decreased ER Ca2 + stores, consistent with chronic intracellular Ca2 + leak. This Ca2 + leak correlated with circulating catecholamine levels. The intracellular Ca2 + leak was significantly reduced in mice treated with the Rycal S107. CHF patients treated with LVAD exhibited a heterogeneous response. Conclusions -In CHF, B-lymphocytes exhibit remodeled leaky
Increasing Healthcare Burden of Chronic Liver Disease Compared to Other Chronic Diseases, 2004-2013.
Asrani, Sumeet K; Kouznetsova, Maria; Ogola, Gerald; Taylor, Thomas; Masica, Andrew; Pope, Brandon; Trotter, James; Kamath, Patrick; Kanwal, Fasiha
2018-05-23
Chronic liver disease (CLD) is a common and expensive condition, and studies of CLD-related hospitalizations have underestimated the true burden of disease. We analyzed data from a large diverse healthcare system to compare time trends in CLD-related hospitalizations with those of congestive heart failure (CHF) or chronic obstructive pulmonary disease (COPD). We collected data from a large healthcare system in Texas on hospitalizations related to CLD (n=27,783), CHF (n=60,415), and COPD (n=34,199) from January 1, 2004 through December 31, 2013. We calculated annual hospitalization rates (per 100,000) and compared hospital course, inpatient mortality, ancillary services and re-admissions. Compared to patients with CHF (median age, 71 years) or COPD (median age 69 years), patients with CLD were significantly younger (median age 57 years; PCLD were uninsured (11.7% vs 5.4% for CHF and 5.4% for COPD; PCLD vs 9.3% for CHF and 5.0% for COPD; PCLD had Medicare (41.5% vs 68.6% with CHF and 70.1% with COPD; PCLD-related hospitalization increased by 92% (from 1295/100,000 to 2490/100,000), compared to 6.7% for CHF (from 3843/100,000 to 4103/100,000) and 48.8% for COPD (from 1775/100,000 to 2642/100,000). During this time period, CLD-related hospitalizations covered by Medicare increased from 31.8% to 41.5%, whereas hospitalizations covered by Medicare did not change for CHF (remained at 70%) or COPD (remained at 70%). Patients with CLD had longer hospital stays (7.3 days vs 6.2 days for CHF or 5.9 days for COPD; PCLD died or were discharged to hospice (14.2% vs 11.5% of patients with CHF and 9.3% of patients with COPD PCLD were readmitted to the hospital within 30 days (25% vs 21.9% of patients with CHF and 20.6% with COPD; PCLD. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
STRUCTURAL STUDY AND INVESTIGATION OF NMR TENSORS ...
African Journals Online (AJOL)
NBO studies were performed to the second-order and perturbative estimates of donor-acceptor interaction have been done. The procedures of gauge-invariant atomic orbital (GIAO) and continuous-set-of-gauge-transformation (CSGT) were employed to calculate isotropic shielding, chemical shifts anisotropy and chemical ...
Lee, C W; Lee, J H; Kim, J J; Park, S W; Hong, M K; Kim, S T; Lim, T H; Park, S J
1999-04-01
Using proton magnetic resonance spectroscopy, we investigated cerebral metabolism and its determinants in congestive heart failure (CHF), and the effects of cardiac transplantation on these measurements. Few data are available about cerebral metabolism in CHF. Fifty patients with CHF (ejection fraction OGM) and parietal white matter (PWM). Absolute levels of the metabolites (N-acetylaspartate, creatine, choline, myo-inositol) were calculated. In PWM only creatine level was significantly lower in CHF than in control subjects, but in OGM all four metabolite levels were decreased in CHF. The creatine level was independently correlated with half-recovery time and duration of heart failure symptoms in PWM (r = -0.56, p OGM (r = 0.58, p < 0.05). Cerebral metabolic abnormalities were improved after successful cardiac transplantation. This study shows that cerebral metabolism is abnormally deranged in advanced CHF and it may serve as a potential marker of the disease severity.
Measurements of Critical Heat Flux using Mass Transfer System
Energy Technology Data Exchange (ETDEWEB)
Hong, Seung Hyun; Chung Bum Jin [Kyunghee University, Yongin (Korea, Republic of)
2016-05-15
In a severe accident, the reactor vessel is heated by the decay heat from core melts and the outer surface of reactor vessel is cooled by the natural convection of water pool. When the heat flux increases, boiling will start. Further increase of the heat flux may result in the CHF, which is generated by the bubble combinations. The CHF means that the reactor vessel was separated with coolant and wall temperature is raised rapidly. It may damage the reactor vessel. Also the CHF indicates the maximum cooling capability of the system. Therefore, the CHF has been used as a criterion for the regulatory and licensing. Mechanism of hydrogen vapor bubbles generated and combined can be simulated water bubbles mechanism. And also the both heat and mass transfer mechanism of CHF can be identified in the same methods. Therefore, the CHF phenomena can be simulated enough by mass transfer.
Review of Critical Heat Flux Correlations for Upward Flow in a Vertical Thin Rectangular Channel
International Nuclear Information System (INIS)
Choi, Gil Sik; Chang, Soon Heung
2014-01-01
From the view point of safety, this type of fuel has higher resistance to earthquake and external impact. The cross section of coolant flow channel in the reactor core composed with the plate fuel is a thin rectangular shape. Thermal-hydraulic characteristics of this thin rectangular channel are different with those of general circular rod fuel bundle flow channel. Accordingly it could be thought that the CHF correlation in a thin rectangular channel is different with that in a circular channel, for which a large number of researches on CHF prediction have been carried out. The objective of this paper is to review previous researches on CHF in a thin rectangular channel, summarize the important conclusion and propose the new simple CHF correlation, which is based on the data set under high pressure and high flow rate condition. The researches on CHF in rectangular channel have been partially carried out according to the pressure, heated surface number, heated surface wettability effect, flow driving force and flow direction conditions. From the literature researches on CHF for upward flow in a vertical thin rectangular channel, some CHF prediction methods were reviewed and compared. There is no universal correlation which can predict CHF at all conditions, but generally, Katto empirical correlation is known to be useful at high pressure and high flow rate. The new simple correlation was developed from the restricted data set, the CHF prediction capacity of which is better than that of Katto. Even though the prediction consistency of the new simple correlation is lower, MAE and RMS error decreased quite. For the more development of the new simple CHF correlation, the more advanced regression analysis method and theoretical analysis should be studied in future
DIAGNOSTIC VALUE OF GALECTIN-3 LEVEL IN PATIENTS WITH CHRONIC HEART FAILURE AND TYPE 2 DIABETES
Directory of Open Access Journals (Sweden)
A. A. Snetkova
2015-09-01
Full Text Available Currently, a greater emphasis is placed on the search for additional biomarkers of chronic heart failure (CHF. Galectin-3, a marker of fibrosis and inflammation, has shown himself as a biomarker of CHF in many studies, but the dynamics of its levels in patients with concomitant diabetes mellitus (DM type 2 is not well-studied.Aim. To identify diagnostic significance of galectin-3 plasma level evaluation and its correlations with echocardiographic criteria for patients with CHF and DM type 2.Material and methods. The study included 33 patients with ischemic CHF (all patients had a history of myocardial infarction and DM type 2. The patients were divided into two groups according to the left ventricle (LV ejection fraction (EF: a group with CHF and preserved ejection fraction (PEF (EF≥50% and with CHF and reduced ejection fraction (EF<50%. Patients underwent clinical laboratory tests and Doppler echocardiography; moreover, the levels of brain natriuretic peptide (BNP and galeсtin-3 were measured.Results. The mean level of galectin-3 in blood plasma in the group with CHF and PEF was significantly higher than in the group with CHF and reduced EF (p=0.007. In the group with CHF and PEF a positive correlation between the level of galectin-3 and diastolic LV function E/E' was found (r=0.620, p=0.01. A significant correlation between galectin-3 level and LV systolic function was stated in the group with reduced EF (r=0.53; p<0.05, while in the group with PEF, the correlation was not significant (p=0.225. In the group of patients with reduced EF a negative correlation between galectin-3 and the volume of left atrium was revealed (r=-0.53; p<0.05.Conclusion. Galectin-3 can be used as a diagnostic biomarker primarily in patients with CHF and PEF.
Review of Critical Heat Flux Correlations for Upward Flow in a Vertical Thin Rectangular Channel
Energy Technology Data Exchange (ETDEWEB)
Choi, Gil Sik; Chang, Soon Heung [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)
2014-05-15
From the view point of safety, this type of fuel has higher resistance to earthquake and external impact. The cross section of coolant flow channel in the reactor core composed with the plate fuel is a thin rectangular shape. Thermal-hydraulic characteristics of this thin rectangular channel are different with those of general circular rod fuel bundle flow channel. Accordingly it could be thought that the CHF correlation in a thin rectangular channel is different with that in a circular channel, for which a large number of researches on CHF prediction have been carried out. The objective of this paper is to review previous researches on CHF in a thin rectangular channel, summarize the important conclusion and propose the new simple CHF correlation, which is based on the data set under high pressure and high flow rate condition. The researches on CHF in rectangular channel have been partially carried out according to the pressure, heated surface number, heated surface wettability effect, flow driving force and flow direction conditions. From the literature researches on CHF for upward flow in a vertical thin rectangular channel, some CHF prediction methods were reviewed and compared. There is no universal correlation which can predict CHF at all conditions, but generally, Katto empirical correlation is known to be useful at high pressure and high flow rate. The new simple correlation was developed from the restricted data set, the CHF prediction capacity of which is better than that of Katto. Even though the prediction consistency of the new simple correlation is lower, MAE and RMS error decreased quite. For the more development of the new simple CHF correlation, the more advanced regression analysis method and theoretical analysis should be studied in future.
[Treatment motivation in patients with chronic cardiorenal syndrome].
Efremova, E V; Shutov, A M; Borodulina, E O
2015-01-01
To study treatment motivation in patients with chronic heart failure (CHF) and in those with CHF concurrent with chronic kidney disease (CKD). A total of 203 patients (130 men and 73 women; mean age, 61.8±9.6 years) with CHF diagnosed and assessed in accordance with the National Guidelines of the All-Russian Research Society of Cardiology and the Heart Failure Society for the diagnosis and treatment of CHF (third edition, 2009) were examined. CKD was diagnosed according to the 2012 National Guidelines of the Research Nephrology Society of Russia. A group of patients with chronic cardiorenal syndrome (CRS) included those with CHF and CKD with a glomerular filtration rate (GFR) of motivation for non-drug and drug treatments were assessed in patients with chronic CRS. CFR was 67.7±17.2 ml/min/1.73 m2; chronic CRS was observed in 89 (44%) patients. Psychological functioning assessment showed that the patients with chronic CRS as compared with those with CHF without CKD had high anxiety and maladaptive disease attitudes. CHF treatment motivation (compliance with lifestyle modification and medication) was proved inadequate and detected only in 31 (15.3%) patients with CHF regardless of the presence of CKD. The specific features of psychological functioning, which affected treatment motivation, were seen in patients with chronic CRS: those who were lowly motivated had a euphoric attitude towards their disease (p=0.03); those who were satisfactorily motivated showed an emotive accentuation of character (p=0.002). The presence of CKD aggravates the clinical course of CHF and negatively affects the psychological functioning of patients with CHF. The patients with chronic CRS are characterized by a low level of motivation for both drug and non-drug treatments, which should be taken into account when managing this cohort of patients.
Energy Technology Data Exchange (ETDEWEB)
Kim, Jae Seung; Kim, Jae Joong; Lim, Ki Chun; Lee, Hee Kyung; Moon, Dae Hyuk [Ulsan University College of Medicine, Seoul (Korea, Republic of)
2002-07-01
Recent reports revealed that cerebral metabolism in CHF was abnormally deranged and proposed as a potential marker of disease severity. Since deranged cerebral metabolism in CHF may result from compromised cerebral perfusion, quantification of CHF may be useful for accurate risk stratification of CHF. Therefore, we investigated whether CHF in patients with CHF is compromised and correlated with clinical parameters. Fifteen patients (M/F:11/5, 45{+-}9yr) with CHF (LVEF<40%) and 7 healthy controls (M/F:5/2, 41{+-}8yr) were prospectively studied. All patients underwent radionuclide angiography including cerebral hemispheres and aortic arch using {sup 99m}Tc-ECD. Global CBF was measured non-invasively by the application of Patlak graphical plot analysis. All patients were also evaluated using a standardized protocol that included echocardiography and clinical evaluation. Global CBF (40.3{+-}5.2 ml/min/100g) of the patients with CHF were significantly lower than those (49.7{+-}2.4 ml/min/100g) of controls (p<0.01). Global CBF were correlated with NYHA functional class (r=-0.617, p=0.43), but not correlated with other clinical parameters such as age (r=-0.463, p=0.082), duration (r=0.237, p>0.1), systolic BP (r=-0.063, p>0.5), LVEF (r=-0.13, p>0.1), LV dimension(r=0.139, p>0.5), and PV pressure gradients (r=0.072, p>0.5). Cerebral perfusion of the patients with CHF was compromised and not correlated with cardiopulmonary hemodynamic parameters.
Energy Technology Data Exchange (ETDEWEB)
Terng, Nilton; Carajilescov, Pedro, E-mail: Nil.terng@gmail.com, E-mail: pedro.carajilescov@ufabc.edu.br [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil). Centro de Engenharia, Modelagem e Ciencias Sociais
2015-07-01
The critical heat flux (CHF) is one of the principal thermal hydraulic limits of PWR type nuclear reactors. The present work consists in the development of an artificial neural network (ANN) to estimate the CHF, based on Look Up Table CHF data, published by Groeneveld (2006). Three parameters were considered in the development of the ANN: the pressure in the range of 1 to 21 MPa, the mass flux in the range of 50 to 8000 kg m{sup -2} s{sup -1} and the thermodynamic quality in the range of - 0.5 to 0.9. The ANN model considered was a multi feed forward net, which have two feedforward ANN. The first one, called main neural network, is used to calculate the result of CHF, and the second, denominated spacenet, is responsible to modify the main neural network according to the input. Comparing the ANN predictions with the data of the Look Up Table, it was observed an average of the ratio of 0.993 and a root mean square error of 13.3%. With the developed ANN, a parametric study of CHF was performed to observe the influence of each parameter in the CHF. It was possible to note that the CHF decreases with the increase of pressure and thermodynamic quality, while CHF increases with the mass flow rate, as expected. However, some erratic trends were also observed which can be attributed to either unknown aspect of the CHF phenomenon or uncertainties in the data. (author)
Effect of pressure on critical heat flux for water in an internally heated annulus
International Nuclear Information System (INIS)
Mishima, Kaichiro; Hibiki, Takashi; Nishihara, Hideaki
2004-01-01
It was pointed out earlier that existing CHF correlations based upon data for annuli at high pressures did not reproduce CHF very well at the atmospheric pressure. It appears to be necessary to investigate CHF at intermediate pressures to interpret the apparent discrepancy between CHFs at high and low pressures. In view of this an experiment was performed to obtain more information on CHF at intermediate pressures and the effect of pressure was discussed in the present study. It was revealed from this study that the effect of pressure on the CHF in the range from 0.1 to 1 MPa could be explained by the annular flow boundary and the critical quality. (author)
DEFF Research Database (Denmark)
Christensen, Heidi Marie; Kistorp, Caroline Michaela Nervil; Schou, Morten
2012-01-01
and to characterize a CHF population with and without cachexia with respect to body composition and related biomarkers. From 2008 to 2011, we screened 238 optimally treated, non-diabetic CHF patients for cardiac cachexia, defined as unintentional non-oedematous weight loss of >5 % over ≥6 months. CHF patients (LVEF...... 45 % (n = 19). The groups were matched for age, sex, and kidney function. Body composition was assessed by dual energy X-ray absorptiometry. The prevalence of cachexia was 10.5 %. Abdominal fat ± SD (%) was reduced in cachectic CHF: 27.4 ± 10.0 versus 37.5 ± 10.6 % (CHF, no cachexia) and 40...
A review of critical heat flux prediction technique and its application in CANDU reactor
International Nuclear Information System (INIS)
Park, Jee Won; Roh, Gyu Hong
1997-09-01
The CHF prediction method being used for CANDU reactor have been critically reviewed. The AECL's CHF prediction totally depends on the look-up table which has been developed from many CHF databank. These databanks include not only the water-cooled bundle-CHF data but also the freon-cooled bundle-CHF data. The CHF look-up tables have been developed by smoothing and interpolating (with some extrapolations) the experimental data to construct a practically useful CHF table. Therefore, the table look-up method has advantages of accuracy, consistency in a wide range of thermal-hydraulic parameters. It seems, however, that since the existing look-up table is constructed by many steps of modification of the original experimental data (e.g., the look-up table is constructed not only using the horizontal flow data but also the vertical flow data), one should be very careful when one try to generate a look-up table for other fuel geometries. In other words, a reliable look-up table can be constructed by performing experiments for new fuel geometry. Finally, it should be noted that the modifications to the original experimental data has simple form with many modification parameters for taking into account of different geometrical effects. This report presents the backbone and the validity of AECL CHF look-up table. (author). 22 refs., 2 tabs., 2 figs
A Randomized Trial Examining Housing First in Congregate and Scattered Site Formats.
Directory of Open Access Journals (Sweden)
Julian M Somers
Full Text Available No previous experimental trials have investigated Housing First (HF in both scattered site (SHF and congregate (CHF formats. We hypothesized that CHF and SHF would be associated with a greater percentage of time stably housed as well as superior health and psychosocial outcomes over 24 months compared to treatment as usual (TAU.Inclusion criteria were homelessness, mental illness, and high need for support. Participants were randomised to SHF, CHF, or TAU. SHF consisted of market rental apartments with support provided by Assertive Community Treatment (ACT. CHF consisted of a single building with supports equivalent to ACT. TAU included existing services and supports.Of 800 people screened, 297 were randomly assigned to CHF (107, SHF (90, or TAU (100. The percentage of time in stable housing over 24 months was 26.3% in TAU (reference; 95% confidence interval (CI = 20.5, 32.0, compared to 74.3% in CHF (95% CI = 69.3, 79.3, p<0.001 and 74.5% in SHF (95% CI = 69.2, 79.7, p<0.001. Secondary outcomes favoured CHF but not SHF compared to TAU.HF in scattered and congregate formats is capable of achieving housing stability among people experiencing major mental illness and chronic homelessness. Only CHF was associated with improvement on select secondary outcomes.Current Controlled Trials: ISRCTN57595077.
Directory of Open Access Journals (Sweden)
Roberto Aquilani
2014-01-01
Full Text Available Exercise intolerance remains problematic in subjects with chronic heart failure (CHF and/or chronic obstructive pulmonary disease (COPD. Recent studies show that supplemented essential amino acids (EAAs may exert beneficial effects on CHF/COPD physical capacity. The results from 3 investigations (2 conducted on CHF and 1 on COPD subjects served as the basis for this paper. The 3 studies consistently showed that elderly CHF and COPD improved exercise intolerance after 1–3 months of EAA supplementation (8 g/d. In CHF exercise capacity increased 18.7% to 23% (watts; bicycle test, and 12% to 22% (meters in 6 min walking test. Moreover, patients reduced their resting plasma lactate levels (by 25% and improved tissue insulin sensitivity by 16% (HOMA index. COPD subjects enjoyed similar benefits as CHF ones. They increased physical autonomy by 78.6% steps/day and decreased resting plasma lactate concentrations by 23%. EAA mechanisms explaining improved exercise intolerance could be increases in muscle aerobic metabolism, mass and function, and improvement of tissue insulin sensitivity (the latter only for the CHF population. These mechanisms could be accounted for by EAA’s intrinsic physiological activity which increases myofibrils and mitochondria genesis in skeletal muscle and myocardium and glucose control. Supplemented EAAs can improve the physical autonomy of subjects with CHF/COPD.
The renal nerves in chronic heart failure: efferent and afferent mechanisms
Schiller, Alicia M.; Pellegrino, Peter R.; Zucker, Irving H.
2015-01-01
The function of the renal nerves has been an area of scientific and medical interest for many years. The recent advent of a minimally invasive catheter-based method of renal denervation has renewed excitement in understanding the afferent and efferent actions of the renal nerves in multiple diseases. While hypertension has been the focus of much this work, less attention has been given to the role of the renal nerves in the development of chronic heart failure (CHF). Recent studies from our laboratory and those of others implicate an essential role for the renal nerves in the development and progression of CHF. Using a rabbit tachycardia model of CHF and surgical unilateral renal denervation, we provide evidence for both renal efferent and afferent mechanisms in the pathogenesis of CHF. Renal denervation prevented the decrease in renal blood flow observed in CHF while also preventing increases in Angiotensin-II receptor protein in the microvasculature of the renal cortex. Renal denervation in CHF also reduced physiological markers of autonomic dysfunction including an improvement in arterial baroreflex function, heart rate variability, and decreased resting cardiac sympathetic tone. Taken together, the renal sympathetic nerves are necessary in the pathogenesis of CHF via both efferent and afferent mechanisms. Additional investigation is warranted to fully understand the role of these nerves and their role as a therapeutic target in CHF. PMID:26300788
Directory of Open Access Journals (Sweden)
Fritzenwanger M
2009-03-01
Full Text Available Abstract Background Endothelial progenitor cells (EPC which are characterised by the simulateous expression of CD34, CD133 and vascular endothelial growth receptor 2 (VEGF 2 are involved in the pathophysiology of congestive heart failure (CHF and their number and function is reduced in CHF. But so far our knowledge about the number of circulating hematopoietic stem/progenitor cells (CPC expressing the early hematopoietic marker CD133 and CD34 in CHF is spares and therefore we determined their number and correlated them with New York Heart Association (NYHA functional class. Methods CD34 and CD133 surface expression was quantified by flow cytometry in the peripheral venous blood of 41 healthy adults and 101 patients with various degrees of CHF. Results CD34+, CD133+ and CD34+/CD133+ cells correlated inversely with age. Both the number of CD34+ and of CD34+/CD133+ cells inversely correlated with NYHA functional class. The number of CD133+ cells was not affected by NYHA class. Furthermore the number of CD133+ cells did not differ between control and CHF patients. Conclusion In CHF the release of CD34+, CD133+ and CD34+/CD133+ cells from the bone marrow seems to be regulated differently. Modulating the releasing process in CHF may be a tool in CHF treatment.
HR Department
2009-01-01
Staff members, fellows and pensioners are reminded that they must notify CERN of any change in their marital status and any change in the income or health insurance cover of their spouse or registered partner, in writing and within 30 calendar days of the change, in accordance with Articles III 6.01 to 6.03 of the Rules of the CERN Health Insurance Scheme (CHIS). Such changes may affect the conditions of the spouse or registered partner’s membership of the CHIS or the payment of the supplementary contribution to the CHIS. For more information see: http://cern.ch/chis/contribsupp.asp From 1.1.2009 onwards, the following indexed monthly supplementary contributions, expressed in Swiss francs, are payable for the various monthly income brackets: •\tmore than 2’500 CHF and up to 4’250 CHF: 134.- •\tmore than 4’250 CHF and up to 7’500 CHF: 234.- •\tmore than 7’500 CHF and up to 10’000 CHF: 369.- •\tmore than 10’000 CHF: 485.- It is in the member of...
2003-01-01
Staff Members, Fellows and Pensioners are reminded that any change in the marital status of members of the personnel, as well as any change in the spouse's income or health insurance cover, shall be notified in writing to CERN, within 30 calendar days of the change, in accordance with Article R IV 1.17 of the Staff Regulations. Such changes may have consequences on the conditions of the spouse's affiliation to the CERN Health Insurance Scheme (CHIS) or on the payment of the supplementary contribution to the CHIS for the coverage of the spouse. In 2003, for the following income brackets, the indexed amounts in Swiss francs of the supplementary contribution are : - more than 30'000 CHF and up to 50'000 CHF: 134.- - more than 50'000 CHF and up to 90'000 CHF: 234.- - more than 90'000 CHF and up to 130'000 CHF: 369.- - more than 130'000 CHF: 468.- It is in the member of the personnel's interest to declare as soon as possible a change in the annual income of his spouse in order that the contribution is adjusted w...
Supplementary contribution payable to the health insurance scheme for the spouse's coverage
Human Resources Department
2005-01-01
Staff Members, Fellows and Pensioners are reminded that any change in the marital status of members of the personnel, as well as any change in the spouse's income or health insurance cover, shall be notified in writing to CERN, within 30 calendar days of the change, in accordance with Article R IV 1.17 of the Staff Regulations. Such changes may have consequences on the conditions of the spouse's affiliation to the CERN Health Insurance Scheme (CHIS) or on the payment of the supplementary contribution to the CHIS for the coverage of the spouse. Changes to the rules and simplification to the system are currently being prepared and should be operational by mid-2005. Meanwhile from 1.1.2005, for the following income brackets, the indexed amounts in Swiss francs of the monthly supplementary contribution are: more than 30'000 CHF and up to 50'000 CHF: 134.- more than 50'000 CHF and up to 90'000 CHF: 234.- more than 90'000 CHF and up to 130'000 CHF: 369.- more than 130'000 CHF: 459.- It is in the member o...
Supplementary contribution payable to the health insurance scheme for the spouse's coverage
HR Department
2007-01-01
Staff Members, Fellows and Pensioners are reminded that any change in their marital status, as well as any change in the spouse or registered partner's income or health insurance cover, shall be notified in writing to CERN, within 30 calendar days of the change, in accordance with Articles III 6.01 to 6.03 of the Rules of the CERN Health Insurance Scheme. Such changes may have consequences on the conditions of the spouse or registered partner's affiliation to the CERN Health Insurance Scheme (CHIS) or on the payment of the supplementary contribution to the CHIS for the coverage of the spouse or registered partner. From 1.1.2007, for the following monthly income brackets, the indexed amounts in Swiss francs of the monthly supplementary contribution are: more than 2'500 CHF and up to 4'250 CHF: 134.- more than 4'250 CHF and up to 7'500 CHF: 234.- more than 7'500 CHF and up to 10'000 CHF: 369.- more than 10'000 CHF: 461.- It is in the member of the personnel's interest to declare a change in the annual ...
Human Resources Division
2002-01-01
Staff members, fellows and pensioners are reminded that any change in the marital status of members of the personnel, as well as any change in the spouse's income or health insurance cover, shall be notified in writing to CERN, within 30 calendar days of the change, in accordance with Article R IV 1.17 of the Staff Regulations. Such changes may have consequences on the affiliation of the spouse to the CERN Health Insurance Scheme (CHIS) or on the payment of the supplementary contribution to the CHIS for the coverage of the spouse. In 2002, for the following income brackets, the indexed amounts in Swiss francs of the supplementary contribution are: more than 30'000 CHF and up to 50'000 CHF: 134.- more than 50'000 CHF and up to 90'000 CHF: 234.- more than 90'000 CHF and up to 130'000 CHF: 369.- more than 130'000 CHF: 461.- It is in the member of the personnel's interest to declare a change in the annual income of his/her spouse as soon as possible in order to adjust contributions with the m...
International Nuclear Information System (INIS)
Cheng Yu; Hong Liquan; Chen Zhaojun
2009-01-01
Objective: To investigate the relationship between brain natriuretic peptide (BNP), angiotensin (AT-II), and aldosterone (ALD) levels in patients with congestive heart failure (CHF). Methods: Plasma levels of BNP (with CLIA) and Angiotensin II (AT-II), aldosterone (ALD) (with RIA) were measured in 98 patients with CHF, 76 cardiac patients without heart faclure, and 86 controls. Results: The plasma levels of BNP, AT-II and ALD in patients (with RIA) CHF were significantly higher than those in the controls. The levels of BNP, AT-II and ALD, CHF patients after therapy were markedly dropped and were significantly lower than those patients before therapy (P<0.01). BNP levels were positively correlated with AT-II and ALD in levels CHF (P<0.05). Conclusion: The over activity of RAA systems may be one of the mechanisms of heart failure. Dynamic observation of changes of BNP, AT-II and ALD may be very useful in assessment of severity and prognosis of patients with CHF. (authors)
International Nuclear Information System (INIS)
Chen Jianxiong; Li Zhuocheng; Tu Hong
2010-01-01
Objective: To evaluate the clinical value of determination of plasma brain natriuretic peptide (BNP) levels in patients with chronic congestive heart failure(CHF). Methods: The levels of plasma BNP were measured with fluorescence immunoassay in 341 patients with chronic CHF and 55 controls. Left ventricular ejection fraction (LVEF), left ventricular end systolic diameter (LVESD) and left ventricular end diastolic diameter (LVEDD) were determined with color doppler ultrasonography in CHF patients. Results: Plasma levels of BNP were significantly increased in patients with CHF as compared with those in controls (P<0.01). There were also significant differences in plasma levels of CHF patients of different clinical stages (P<0.01). There was obvious correlation between plasma levels of BNP and the values of LVEF, LVESD and LVEDD (r was-0.62, +0.54 and +0.60 respectively, P<0.01). Conclusion: Plasma level of BNP is a sensitive indicator for assessment of ventricle function in CHF patients. (authors)
Cardiac asthma in elderly patients: incidence, clinical presentation and outcome
Directory of Open Access Journals (Sweden)
Ray Patrick
2007-05-01
Full Text Available Abstract Background Cardiac asthma is common, but has been poorly investigated. The objective was to compare the characteristics and outcome of cardiac asthma with that of classical congestive heart failure (CHF in elderly patients. Methods Prospective study in an 1,800-bed teaching hospital. Results Two hundred and twelve consecutive patients aged ≥ 65 years presenting with dyspnea due to CHF (mean age of 82 ± 8 years were included. Findings of cardiac echocardiography and natriuretic peptides levels were used to confirm CHF. Cardiac asthma patients were defined as a patient with CHF and wheezing reported by attending physician upon admission to the emergency department. The CHF group (n = 137 and the cardiac asthma group (n = 75, differed for tobacco use (34% vs. 59%, p 2 (47 ± 15 vs. 41 ± 11 mmHg, p Conclusion Patients with cardiac asthma represented one third of CHF in elderly patients. They were more hypercapnic and experienced more distal airway obstruction. However, outcomes were similar.
An Experimental study of Fullerene (C60) Nano-fluids on Pool Boiling Conditions
International Nuclear Information System (INIS)
Melani, Ai; Shin, Byoong Su; Chang, Soon Heung
2009-01-01
Critical heat flux (CHF) is directly related to the performance of the system since CHF limits the heat transfer of a heat transfer system. Significant enhancement of CHF allows reliable operation of equipment with more margins to operational limit and more economic cost saving. The previous results show that the nano-fluids significantly enhanced pool boiling CHF compared to pure water. It was supposed that CHF enhancement was due to increased thermal conductivity of fluids, change of bubble shape and behavior, and nano-particle coating of the boiling surface. The previous researches also show that mainly the pool boiling experiment was employed metal particles. Fullerene (C 60 ) is a novel carbon allotrope that was first discovered in 1985 by a winner noble 'Sir Harold W.Kroto, Richard E. Smalley and Robert F.Curl Jr'. In this study we report the first CHF experiment in pool boiling conditions using Fullerene (C 60 ) nanofluids
Study on tube critical heat flux data treatment with artificial neural networks
International Nuclear Information System (INIS)
Han Lang; Shan Jianqiang
2005-01-01
Prediction of the Critical Heat Flux (CHF) are analyzed by Artificial Neural Networks (ANN) to a CHF database for upward flow of water in uniformly heated vertical round tubes. The analysis is performed with three viewpoints hypothesis, i.e. for fixed inlet condition, fixed exit condition and local condition. Half of 6941 from CHF database data is trained through ANN, the trained ANN predicts the total CHF data better than any other conventional correlations, showing RMS error of 6.6%, 10.39% and 21.39%, respectively. (author)
International Nuclear Information System (INIS)
Fulfs, H.; Katsaounis, A.; Kreubig, M.; Minden, C. von; Orlowski, R.
1980-01-01
The results will be described in exemplary presentations completely and concluding. The experimental examination of the steady state simularity of critical heat flux (CHF) in freon 12 and water at identical PWR-5 x 15-rod bundles will show that hot rod/hot channels position as well as CHF can be transformed from model to original fluid with good accuracy. The investigated mass flow and power transients (only in freon 12) point out a definite influence of initial and boundary conditions on CHF and CHF time delay at changing rates higher than 10 to 20%/s. On the contrary simulation of primary pump failure (LOFA) shows no or only small improvement in CHF behaviour while a coupled Scram prevents from reaching the boiling crisis. (orig.) [de
Tu, Huiyin; Liu, Jinxu; Zhang, Dongze; Zheng, Hong; Patel, Kaushik P; Cornish, Kurtis G; Wang, Wei-Zhong; Muelleman, Robert L; Li, Yu-Long
2014-01-15
Chronic heart failure (CHF) is characterized by decreased cardiac parasympathetic and increased cardiac sympathetic nerve activity. This autonomic imbalance increases the risk of arrhythmias and sudden death in patients with CHF. We hypothesized that the molecular and cellular alterations of cardiac postganglionic parasympathetic (CPP) neurons located in the intracardiac ganglia and sympathetic (CPS) neurons located in the stellate ganglia (SG) possibly link to the cardiac autonomic imbalance in CHF. Rat CHF was induced by left coronary artery ligation. Single-cell real-time PCR and immunofluorescent data showed that L (Ca(v)1.2 and Ca(v)1.3), P/Q (Ca(v)2.1), N (Ca(v)2.2), and R (Ca(v)2.3) types of Ca2+ channels were expressed in CPP and CPS neurons, but CHF decreased the mRNA and protein expression of only the N-type Ca2+ channels in CPP neurons, and it did not affect mRNA and protein expression of all Ca2+ channel subtypes in the CPS neurons. Patch-clamp recording confirmed that CHF reduced N-type Ca2+ currents and cell excitability in the CPP neurons and enhanced N-type Ca2+ currents and cell excitability in the CPS neurons. N-type Ca2+ channel blocker (1 μM ω-conotoxin GVIA) lowered Ca2+ currents and cell excitability in the CPP and CPS neurons from sham-operated and CHF rats. These results suggest that CHF reduces the N-type Ca2+ channel currents and cell excitability in the CPP neurons and enhances the N-type Ca2+ currents and cell excitability in the CPS neurons, which may contribute to the cardiac autonomic imbalance in CHF.
De Smedt, R.H.E.; Denig, P.; Haaijer-Ruskamp, F.M.; Jaarsma, T.
Data on medication adverse effects (AEs) in chronic heart failure (CHF) are primarily based on results from clinical trials. Little is known about AEs perceived by CHF patients in daily practice and how patients deal with these subjective AEs. To describe the scope and nature of perceived AEs of CHF
Critical heat flux predictions for the Sandia Annular Core Research Reactor
International Nuclear Information System (INIS)
Rao, D.V.; El-Genk, M.S.
1994-08-01
This study provides best estimate predictions of the Critical Heat Flux (CHF) and the Critical Heat Flux Ratio (CHFR) to support the proposed upgrade of the Annual Core Research Reactor (ACRR) at Sandia National Laboratories (SNL) from its present value of 2 MWt to 4 MWt. These predictions are based on the University of New Mexico (UNM) - CHF correlation, originally developed for uniformly heated vertical annuli. The UNM-CHF correlation is applicable to low-flow and low-pressure conditions, which are typical of those in the ACRR. The three hypotheses that examined the effect of the nonuniform axial heat flux distribution in the ACRR core are (1) the local conditions hypotheses, (2) the total power hypothesis, and (3) the global conditions hypothesis. These hypotheses, in conjunction with the UNM-CHF correlation, are used to estimate the CHF and CHFR in the ACRR. Because the total power hypothesis predictions of power per rod at CHF are approximately 15%-20% lower than those corresponding to saturation exit conditions, it can be concluded that the total power hypothesis considerably underestimates the CHF for nonuniformly heated geometries. This conclusion is in agreement with previous experimental results. The global conditions hypothesis, which is more conservative and more accurate of the other two, provides the most reliable predictions of CHF/CHFR for the ACRR. The global conditions hypothesis predictions of CHFR varied between 2.1 and 3.9, with the higher value corresponding to the lower water inlet temperature of 20 degrees C
Liu, Hui; Tian, Yaohua; Song, Jing; Cao, Yaying; Xiang, Xiao; Huang, Chao; Li, Man; Hu, Yonghua
2018-03-01
There is growing interest in the association between ambient air pollution and congestive heart failure (CHF), but research data from developing countries are very limited. The primary aim of this study was to examine the association between short-term exposure to air pollution and hospital admission for CHF in China. A time-stratified case-crossover study was conducted between 2014 and 2015 in 26 large Chinese cities among 105,501 CHF hospitalizations. Conditional logistic regression models were applied to estimate the percentage changes in CHF admissions in relation to per interquartile range increases in air pollutant concentrations. Air pollution was positively associated with CHF hospitalizations. An interquartile range increase in fine particulate, particulate matter less than 10 µm in aerodynamic diameter, sulfur dioxide, nitrogen dioxide, carbon monoxide, and ozone concentrations on the current day corresponded to 1.2% (95% confidence interval [CI] 0.5%, 1.8%), 1.3% (95% CI 0.5%, 2.0%), 1.0% (95% CI 0.2%, 1.7%), 1.6% (95% CI 0.6%, 2.5%), 1.2% (95% CI 0.5%, 1.9%), and 0.4% (95% CI -0.9%, 1.7%) increases in CHF admissions, respectively. In conclusion, our findings contribute to the limited scientific literature concerning the effects of air pollution on CHF risk for high-exposure settings typical in developing countries, which may have significant public health implications for prevention of CHF in China. Copyright © 2017 Elsevier Inc. All rights reserved.
Investigation of Body Force Effects on Flow Boiling Critical Heat Flux
Zhang, Hui; Mudawar, Issam; Hasan, Mohammad M.
2002-01-01
The bubble coalescence and interfacial instabilities that are important to modeling critical heat flux (CHF) in reduced-gravity systems can be sensitive to even minute body forces. Understanding these complex phenomena is vital to the design and safe implementation of two-phase thermal management loops proposed for space and planetary-based thermal systems. While reduced gravity conditions cannot be accurately simulated in 1g ground-based experiments, such experiments can help isolate the effects of the various forces (body force, surface tension force and inertia) which influence flow boiling CHF. In this project, the effects of the component of body force perpendicular to a heated wall were examined by conducting 1g flow boiling experiments at different orientations. FC-72 liquid was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface at conditions approaching CHF. High-speed video imaging was employed to capture dominant CHF mechanisms. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed great sensitivity to orientation for flow velocities below 0.2 m/s, where very small CHF values where measured, especially with downflow and downward-facing heated wall orientations. High flow velocities dampened the effects of orientation considerably. Figure I shows representative images for the different CHF regimes. The Wavy Vapor Layer regime was dominant for all high velocities and most orientations, while all other regimes were encountered at low velocities, in the downflow and/or downward-facing heated wall orientations. The Interfacial Lift-off model was modified to predict the effects of orientation on CHF for the dominant Wavy Vapor Layer regime. The photographic study captured a fairly continuous wavy vapor layer travelling along the heated wall while permitting liquid
International Nuclear Information System (INIS)
Williams, C.L.; Beus, S.G.
1980-05-01
Experiments were performed to establish the critical heat flux (CHF) characteristics of heavy water and light water. Testing was performed with the up-flow of heavy and of light water within a 0.3744 inch inside diameter circular tube with 72.3 inches of heated length. Comparisons were made between heavy water and light water critical heat flux levels for the same local equilibrium quality at CHF, operating pressure, and nominal mass velocity. Results showed that heavy water CHF values were, on the average, 8 percent below the light water CHF values
STRUCTURAL STUDY AND INVESTIGATION OF NMR TENSORS ...
African Journals Online (AJOL)
theory. The structural and vibrational properties of dopamine-4-N7GUA and ... There is evidence, however, that DA is involved in the ... spectra to the results of ab initio gauge-invariant atomic orbital (GIAO) [14-17] and continuous- ..... Nicholls, G. Proteins, transmitter & synapses, Blackwell Scientific Publication: Scotland;.
The button effect of CANFLEX bundle on the critical heat flux and critical channel power
Energy Technology Data Exchange (ETDEWEB)
Park, Joo Hwan; Jun, Jisu; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Dimmick, G R; Bullock, D E; Inch, W [Atomic Energy of Canada Limited, Ontario (Canada)
1998-12-31
A CANFLEX (CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5 mm) to reduce maximum element power rating and buttons to enhance the critical heat flux (CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant R-134a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power (CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF`s for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only for high pressure conditions. It indicates that the button is a useful design for CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions. 5 refs., 11 figs. (Author)
The button effect of CANFLEX bundle on the critical heat flux and critical channel power
Energy Technology Data Exchange (ETDEWEB)
Park, Joo Hwan; Jun, Jisu; Suk, Ho Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Dimmick, G. R.; Bullock, D. E.; Inch, W. [Atomic Energy of Canada Limited, Ontario (Canada)
1997-12-31
A CANFLEX (CANdu FLEXible fuelling) 43-element bundle has developed for a CANDU-6 reactor as an alternative of 37-element fuel bundle. The design has two diameter elements (11.5 and 13.5 mm) to reduce maximum element power rating and buttons to enhance the critical heat flux (CHF), compared with the standard 37-element bundle. The freon CHF experiments have performed for two series of CANFLEX bundles with and without buttons with a modelling fluid as refrigerant R-134a and axial uniform heat flux condition. Evaluating the effects of buttons of CANFLEX bundle on CHF and Critical Channel Power (CCP) with the experimental results, it is shown that the buttons enhance CCP as well as CHF. All the CHF`s for both the CANFLEX bundles are occurred at the end of fuel channel with the high dryout quality conditions. The CHF enhancement ratio are increased with increase of dryout quality for all flow conditions and also with increase of mass flux only for high pressure conditions. It indicates that the button is a useful design for CANDU operating condition because most CHF flow conditions for CANDU fuel bundle are ranged to high dryout quality conditions. 5 refs., 11 figs. (Author)
The Renal Nerves in Chronic Heart Failure: Afferent and Efferent Mechanisms
Directory of Open Access Journals (Sweden)
Alicia Marie Schiller
2015-08-01
Full Text Available The function of the renal nerves has been an area of scientific and medical interest for many years. The recent advent of a minimally invasive catheter-based method of renal denervation has renewed excitement in understanding the afferent and efferent actions of the renal nerves in multiple diseases. While hypertension has been the focus of much this work, less attention has been given to the role of the renal nerves in the development of chronic heart failure (CHF. Recent studies from our laboratory and those of others implicate an essential role for the renal nerves in the development and progression of CHF. Using a rabbit tachycardia model of CHF and surgical unilateral renal denervation, we provide evidence for both renal efferent and afferent mechanisms in the pathogenesis of CHF. Renal denervation prevented the decrease in renal blood flow observed in CHF while also preventing increases in Angiotensin-II receptor protein in the microvasculature of the renal cortex. Renal denervation in CHF also reduced physiological markers of autonomic dysfunction including an improvement in arterial baroreflex function, heart rate variability, and decreased resting cardiac sympathetic tone. Taken together, the renal sympathetic nerves are necessary in the pathogenesis of CHF via both efferent and afferent
Directory of Open Access Journals (Sweden)
Arun K. Verma
2012-02-01
Full Text Available While attempting to develop low salt, low fat and high fibre chicken nuggets, the effect of partial (40% common salt substitution and incorporation of chickpea hull flour (CHF at three different levels viz., 5, 7.5 and 10% (Treatments in pre-standardized low fat chicken nuggets (Control were observed. Common salt replacement with salt substitute blend led to a significant decrease in pH, emulsion stability, moisture, ash, hardness, cohesiveness, gumminess and chewiness values while incorporation of CHF in low salt, low fat products resulted in decreased emulsion stability, cooking yield, moisture, protein, ash, color values, however dietary fibre and textural properties were increased (p<0.01. Lipid profile revealed a decrease in total cholesterol and glycolipid contents with the incorporation of CHF (p<0.01. All the sensory attributes except appearance and flavor, remained unaffected with salt replacement, while addition of CHF resulted in lower sensory scores (p<0.01. Among low salt, low fat chicken nuggets with CHF, incorporation CHF at 5% level was found optimum having sensory ratings close to very good. Thus most acceptable low salt, low fat and high fibre chicken nuggets could be developed by a salt replacement blend and addition of 5% CHF.
International Nuclear Information System (INIS)
Jiang, B.T.; Zhao, F.Y.
2013-01-01
Highlights: ► CHF data are collected from the published literature. ► Less training data are used to train the LSSVR model. ► PSO is adopted to optimize the key parameters to improve the model precision. ► The reliability of LSSVR is proved through parametric trends analysis. - Abstract: In view of practical importance of critical heat flux (CHF) for design and safety of nuclear reactors, accurate prediction of CHF is of utmost significance. This paper presents a novel approach using least squares support vector regression (LSSVR) and particle swarm optimization (PSO) to predict CHF. Two available published datasets are used to train and test the proposed algorithm, in which PSO is employed to search for the best parameters involved in LSSVR model. The CHF values obtained by the LSSVR model are compared with the corresponding experimental values and those of a previous method, adaptive neuro fuzzy inference system (ANFIS). This comparison is also carried out in the investigation of parametric trends of CHF. It is found that the proposed method can achieve the desired performance and yields a more satisfactory fit with experimental results than ANFIS. Therefore, LSSVR method is likely to be suitable for other parameters processing such as CHF
Organizational structure for chronic heart failure and chronic obstructive pulmonary disease.
Rinne, Seppo T; Liu, Chuan-Fen; Wong, Edwin S; Hebert, Paul L; Heidenreich, Paul; Bastian, Lori A; Au, David H
2016-03-01
In contrast to chronic heart failure (CHF), measures of quality of care for chronic obstructive pulmonary disease (COPD) are poor. Our objective was to examine differences in organizational structure available to support quality of care for patients with CHF and COPD. We performed 2 nationwide surveys exploring organizational structure for the management of CHF and COPD. We surveyed the chief of medicine and the chief of cardiology and pulmonary medicine at 120 Veterans Affairs facilities in the United States. Analogous questions about organizational structure that enhanced adherence to guideline-based care were compared between CHF and COPD surveys. We found large and notable differences in the organizational structure for disease management, with systematically less attention given to COPD than CHF. These differences were evident in multiple processes of care. Key differences included fewer facilities: having COPD clinics than CHF clinics (12.7% vs 50.8%; P organizational structure existed for COPD than CHF. Lack of organizational structure for COPD likely impedes an organization's abilities to encourage high-quality care and avoid recently implemented hospital readmission penalties. Our results suggest the need to develop a systematic approach for healthcare systems to provide essential organizational structure based on the burden of disease in the population.
Ameliorative effect of Draba nemorosa extract on chronic heart ...
African Journals Online (AJOL)
Purpose: To evaluate the effect of Draba nemorosa extract (DNE) on oxidative stress and hemodynamics in rats with chronic congestive heart failure (CHF). Methods: Adriamycin was used to establish CHF in Sprague Dawley (SD) rat model. Six groups of SD rats were used in this study: control group, CHF group, captopril ...
International Nuclear Information System (INIS)
Monde, Masanori; Mitsutake, Yuichi; Ishida, Kenji; Hino, Ryutaro
2003-03-01
An ultra high critical heat flux (CHF) has been challenged with a highly subcooled water jet impinging on a small rectangular heated surface. Major objective of the study is to achieve an ultra high heat flux cooling as large as 100 MW/m 2 and to establish an accurate estimation method of the CHF. The experiments were carried out over the experimental range; a fixed jet diameter of 2 mm, jet velocity of 5 - 35 m/s, degree of subcooling of 80 - 170 K and system pressure of 0.1 - 1.0 MPa. The rectangular heated surface with a thin nickel foil of 0.03 - 0.3 mm in thickness, 5 and 10 mm in length, and 4 mm in width and heated by a direct current. Effects of thickness of heater wall, jet velocity and subcooling on the CHF were experimentally elucidated. The experimental results show that the CHF decreases about 50% as the heater thickness, namely heat capacity of heater decreases. Characteristics of the CHF with heater length of 10 mm are correlated within ±20% by the generalized correlation of subcooled CHF proposed by the authors. However, the CHF with the shorter heater length of 5 mm shows large deviation of -40% especially at lower subcooling and higher velocity. The maximum CHF of 212 MW/m 2 was achieved at the subcooling of 151 K, the jet velocity of 35 m/s and system pressure of 0.5 MPa. The maximum CHF under atmospheric pressure approaches to 48% of the ultimate maximum heat flux given by the assumptions that vapor molecules leave a liquid-vapor interface at the average speed of a Boltzman-Maxwellian gas and any molecules returning to the interface are not permitted. The ratio of the CHF and ultimate maximum heat flux was considerably enhanced from the existing record of 30%. This study can give the feasibility of ultra high heat flux removal facing in a development of components such as a diverter of a fusion reactor. (author)
An analytic model of pool boiling critical heat flux on an immerged downward facing curved surface
International Nuclear Information System (INIS)
He, Hui; Pan, Liang-ming; Wu, Yao; Chen, De-qi
2015-01-01
Highlights: • Thin liquid film and supplement of liquid contribute to the CHF. • CHF increases from the bottom to the upper of the lowerhead. • Evaporation of thin liquid film is dominant nearby bottom region. • The subcooling has significant effects on the CHF. - Abstract: In this paper, an analytical model of the critical heat flux (CHF) on the downward facing curved surface for pool boiling has been proposed, which hypothesizes that the CHF on the downward facing curved is composed of two parts, i.e. the evaporation of the thin liquid film underneath the elongated bubble adhering to the lower head outer surface and the depletion of supplement of liquid due to the relative motion of vapor bubbles along with the downward facing curved. The former adopts the Kelvin–Helmholtz instability analysis of vapor–liquid interface of the vapor jets which penetrating in the thin liquid film. When the heat flux closing to the CHF point, the vapor–liquid interface becomes highly distorted, which block liquid to feed the thin liquid film and the thin liquid film will dry out gradually. While the latter considers that the vapor bubbles move along with the downward facing curved surface, and the liquid in two-phase boundary layer enter the liquid film that will be exhausted when the CHF occurs. Based on the aforementioned mechanism and the energy balance between the thin liquid film evaporation and water feeding, and taking the subcooling of the bulk water into account, the mathematic model about the downward facing curved surface CHF has been proposed. The CHF of the downward facing curved surface for pool boiling increases along with the downward facing orientation except in the vicinity of bottom center region, because in this region the vapor bubble almost stagnates and the evaporation of the thin liquid film is dominant. In addition, the subcooling has significant effect on the CHF. Comparing the result of this model with the published experimental results show
Zhu, Yujie; Hanafy, Mohamed A; Killingsworth, Cheryl R; Walcott, Gregory P; Young, Martin E; Pogwizd, Steven M
2014-01-01
Patients with chronic heart failure (CHF) exhibit a morning surge in ventricular arrhythmias, but the underlying cause remains unknown. The aim of this study was to determine if heart rate dynamics, autonomic input (assessed by heart rate variability (HRV)) and nonlinear dynamics as well as their abnormal time-of-day-dependent oscillations in a newly developed arrhythmogenic canine heart failure model are associated with a morning surge in ventricular arrhythmias. CHF was induced in dogs by aortic insufficiency & aortic constriction, and assessed by echocardiography. Holter monitoring was performed to study time-of-day-dependent variation in ventricular arrhythmias (PVCs, VT), traditional HRV measures, and nonlinear dynamics (including detrended fluctuations analysis α1 and α2 (DFAα1 & DFAα2), correlation dimension (CD), and Shannon entropy (SE)) at baseline, as well as 240 days (240 d) and 720 days (720 d) following CHF induction. LV fractional shortening was decreased at both 240 d and 720 d. Both PVCs and VT increased with CHF duration and showed a morning rise (2.5-fold & 1.8-fold increase at 6 AM-noon vs midnight-6 AM) during CHF. The morning rise in HR at baseline was significantly attenuated by 52% with development of CHF (at both 240 d & 720 d). Morning rise in the ratio of low frequency to high frequency (LF/HF) HRV at baseline was markedly attenuated with CHF. DFAα1, DFAα2, CD and SE all decreased with CHF by 31, 17, 34 and 7%, respectively. Time-of-day-dependent variations in LF/HF, CD, DFA α1 and SE, observed at baseline, were lost during CHF. Thus in this new arrhythmogenic canine CHF model, attenuated morning HR rise, blunted autonomic oscillation, decreased cardiac chaos and complexity of heart rate, as well as aberrant time-of-day-dependent variations in many of these parameters were associated with a morning surge of ventricular arrhythmias.
Directory of Open Access Journals (Sweden)
Yujie Zhu
Full Text Available Patients with chronic heart failure (CHF exhibit a morning surge in ventricular arrhythmias, but the underlying cause remains unknown. The aim of this study was to determine if heart rate dynamics, autonomic input (assessed by heart rate variability (HRV and nonlinear dynamics as well as their abnormal time-of-day-dependent oscillations in a newly developed arrhythmogenic canine heart failure model are associated with a morning surge in ventricular arrhythmias. CHF was induced in dogs by aortic insufficiency & aortic constriction, and assessed by echocardiography. Holter monitoring was performed to study time-of-day-dependent variation in ventricular arrhythmias (PVCs, VT, traditional HRV measures, and nonlinear dynamics (including detrended fluctuations analysis α1 and α2 (DFAα1 & DFAα2, correlation dimension (CD, and Shannon entropy (SE at baseline, as well as 240 days (240 d and 720 days (720 d following CHF induction. LV fractional shortening was decreased at both 240 d and 720 d. Both PVCs and VT increased with CHF duration and showed a morning rise (2.5-fold & 1.8-fold increase at 6 AM-noon vs midnight-6 AM during CHF. The morning rise in HR at baseline was significantly attenuated by 52% with development of CHF (at both 240 d & 720 d. Morning rise in the ratio of low frequency to high frequency (LF/HF HRV at baseline was markedly attenuated with CHF. DFAα1, DFAα2, CD and SE all decreased with CHF by 31, 17, 34 and 7%, respectively. Time-of-day-dependent variations in LF/HF, CD, DFA α1 and SE, observed at baseline, were lost during CHF. Thus in this new arrhythmogenic canine CHF model, attenuated morning HR rise, blunted autonomic oscillation, decreased cardiac chaos and complexity of heart rate, as well as aberrant time-of-day-dependent variations in many of these parameters were associated with a morning surge of ventricular arrhythmias.
Energy Technology Data Exchange (ETDEWEB)
Tsukamoto, Masaki; Kato, Shuji; Okamoto, Akio; Kawasaki, Tatsuya; Yamamoto, Teruyuki; Yoneyama, Satoshi; Tatsukawa, Hirotaka; Ida, Kazunori [Asahi Univ., Hozumi, Gifu (Japan). Murakami Memorial Hospital; Terada, Koji
1997-11-01
The subjects were 32 patients who had undergone hemodialysis treatment for an average of 17 yr. MIBG myocardial scintigraphy was obtained from SPECT and anterior planar images at 15 min and 4 hr after MIBG injection. Myocardial MIBG uptake was quantified by the heart-to-mediastinum uptake ratio on delayed planar images (H/M) and the mean myocardial MIBG washout rate at 4 hr was calculated by using the Bull`s eye map (MC). The mean lung MIBG washout rate at 4 hr was also obtained from planar images (LC). The left ventricular end diastolic dimension (LVDd), percent fractional shortening (%FS), wall thickness and the ratio of peak velocity of early rapid filling to peak velocity of inflow due to the atrial contraction (E/A) were measured by echocardiography. The patients were divided according to the severity of congestive heart failure (CHF): NYHA classification grade I or II vs. grade III or IV. The severe CHF group showed decreased H/M, LC and dilatation of LVDd. Twenty-two patients were clinically followed up for one and a half years. Seven had acute worsening of CHF and required admission to a hospital. The other 15 patients did not require admission. H/M and LC were decreased, and E/A was increased in the former group. Eighteen of the 24 patients with mild CHF were followed up and classified according to the clinical course whether or not they had acute worsening of CHF. In the acute worsening group, H/M and LC were decreased, and E/A was increased compared with the non-acute worsening group. Thus, H/M and LC indicate the severity and the prognosis of chronic hemodialysis patients with CHF. Dilatation of LVDd reflects the severity of CHF, but it cannot predict the clinical course, because LVDd is always reduced by the medication for CHF. Increased E/A was found in the acute worsening CHF group, but many factors influence the E/A value and increased E/A alone cannot be prognostic for the clinical course of CHF. (K.H.)
Hemostatic biomarkers in dogs with chronic congestive heart failure
DEFF Research Database (Denmark)
Tarnow, Inge; Falk, Torkel; Tidholm, Anna
2007-01-01
Background: Chronic congestive heart failure (CHF) in humans is associated with abnormal hemostasis, and abnormalities in hemostatic biomarkers carry a poor prognosis. Alterations in hemostatic pathways can be involved in the pathogenesis of CHF in dogs, and microthrombosis in the myocardium could...... contribute to increased mortality. Hypothesis: That plasma concentration or activity of hemostatic biomarkers is altered in dogs with CHF and that these factors predict mortality. Animals: Thirty-four dogs with CHF caused by either dilated cardiomyopathy (DCM, n = 14) or degenerative valvular disease (CDVD......, n = 20) compared with 23 healthy age-matched control dogs were included in this study. Dogs with CHF were recruited from 2 referral cardiology clinics, and control dogs were owned by friends or colleagues of the investigators. Methods: Clinical examination and echocardiography were performed in all...
Critical heat flux of forced convection boiling in an oscilating acceleration field. Pt. 1
International Nuclear Information System (INIS)
Otsuji, T.; Kurosawa, A.
1982-01-01
The influence of periodically varying acceleration on critical heat flux (CHF) of Freon-113 flowing upward in a uniformly heated vertical annular channel has been studied experimentally. The freon loop was oscillated vertically to determine the ratio of CHF in the oscillating acceleration field to the corresponding stationary value. The amplitude of inlet flow oscillation induced by variation of acceleration, which causes early CHF, is proportional to the acceleration amplitude. The dependence of inlet flow rate on the oscillating acceleration decreases with increasing inlet subcooling, and no oscillation of inlet flow is observed in the case of negative exit quality (subcooled boiling). Nevertheless the degradation of CHF is more remarkable in the low quality region. This result suggests the necessity to introduce an other mechanism of early CHF than flow oscillation. (orig.)
Review of issues relating to enhancement of critical heat flux in nuclear reactors - 15220
International Nuclear Information System (INIS)
Hasan, S.M.K.; Chowdhury, M.A.Z.; Sarkar, M.A.R.
2015-01-01
Critical heat flux (CHF) is manifested by sharp reduction in heat transfer coefficient and a drastic rise in fuel rod surface temperature, which may lead to failure of the fuel cladding and is of immense importance in reactor design and operation. In this paper, the existing literature on CHF is studied and analyzed. Different modeling techniques such as geometry modeling and fluid modeling are highlighted. CHF enhancement techniques such as swirl flow, porous coating, nano-fluids or mechanical vibrations are analyzed and their suitability for different applications is discussed. The advances in prediction methods for tubes and rod bundles are also presented. CHF correlations and their applications have been compiled to estimate the CHF for fluids other than water or other geometries. Finally, future research needs are identified and presented. (authors)
Ranasinghe, Isuru; Naoum, Chris; Aliprandi-Costa, Bernadette; Sindone, Andrew P; Steg, P Gabriel; Elliott, John; McGarity, Bruce; Lefkovits, Jeffrey; Brieger, David
2012-05-01
The outcome of patients with chronic heart failure (CHF) following an ischaemic event is poorly understood. We evaluated the management and outcomes of CHF patients presenting with an acute coronary syndrome (ACS) and explored changes in outcomes over time. A total of 5556 patients enrolled in the Australia-New Zealand population of the Global Registry of Acute Coronary Events (GRACE) between 1999 and 2007 were included. Patients with CHF (n = 609) were compared with those without CHF (n = 4947). Patients with CHF were on average 10 years older, were more likely to be female, had more co-morbidities and cardiac risk factors, and were more likely to have a prior history of angina, myocardial infarction, and revascularization by coronary artery bypass graft (CABG) when compared with those without CHF. CHF was associated with a substantial increase in in-hospital renal failure [odds ratio (OR) 1.76, 95% confidence interval (CI) 1.15-2.71], readmission post-discharge (OR 1.47, 95% CI 1.17-1.90), and 6-month mortality (OR 2.25, 95% CI 1.55-3.27). Over the 9 year study period, in-hospital and 6 month mortality in those with CHF declined by absolute rates of 7.5% and 14%, respectively. This was temporally associated with an increase in prescription of thienopyridines, beta-blockers, statins, and angiotensin II receptor blockers, increased rates of coronary angiography, and 31.8% absolute increase in referral rates for cardiac rehabilitation. Acute coronary syndrome patients with pre-existing CHF are a very high risk group and carry a disproportionate mortality burden. Encouragingly, there was a marked temporal improvement in outcomes over a 9 year period with an increase in evidence-based treatments and secondary preventative measures.
Speicher, Paul J; Ganapathi, Asvin M; Englum, Brian R; Vaslef, Steven N
2014-08-01
Over the past 2 decades, laparoscopy has been established as a superior technique in many general surgery procedures. Few studies, however, have examined the impact of the use of a laparoscopic approach in patients with symptomatic congestive heart failure (CHF). Because pneumoperitoneum has known effects on cardiopulmonary physiology, patients with CHF may be at increased risk. This study examines current trends in approaches to patients with CHF and effects on perioperative outcomes. The 2005-2011 National Surgical Quality Improvement Program Participant User File was used to identify patients who underwent the following general surgery procedures: Appendectomy, segmental colectomy, small bowel resection, ventral hernia repair, and splenectomy. Included for analysis were those with newly diagnosed CHF or chronic CHF with new signs or symptoms. Trends of use of laparoscopy were assessed across procedure types. The primary endpoint was 30-day mortality. The independent effect of laparoscopy in CHF was estimated with a multiple logistic regression model. A total of 265,198 patients were included for analysis, of whom 2,219 were identified as having new or recently worsened CHF. Of these patients, there were 1,300 (58.6%) colectomies, 486 (21.9%) small bowel resections, 216 (9.7%) ventral hernia repairs, 141 (6.4%) appendectomies, and 76 (3.4%) splenectomies. Laparoscopy was used less frequently in patients with CHF compared with their non-CHF counterparts, particularly for nonelective procedures. Baseline characteristics were similar for laparoscopy versus open procedures with the notable exception of urgent/emergent case status (36.4% vs 71.3%; P surgery procedures, particularly in urgent/emergent cases. Despite these patterns and apparent preferences, laparoscopy seems to offer a safe alternative in appropriately selected patients. Because morbidity and mortality were considerable regardless of approach, further understanding of appropriate management in this
Heart Failure and Exercise: A Narrative Review of the Role of Self-Efficacy.
Ha, Francis J; Hare, David L; Cameron, James D; Toukhsati, Samia R
2018-01-01
Chronic heart failure (CHF) is a common, debilitating condition associated with significant health and economic burden. CHF management is multidisciplinary, however, achieving better health relies on a collaborative effort and patient engagement in self-care. Despite the importance of self-care in CHF, many patients have poor adherence to their medical and lifestyle regimens, in particular with regards to engaging in physical exercise. The patient's confidence in their ability, otherwise known as self-efficacy, is an important determinant of CHF health outcomes, most likely due to its effect on the uptake of CHF self-care activities especially exercise initiation and maintenance. Self-efficacy is responsive to experience such as exercise training, however the critical components of exercise interventions to improve self-efficacy have yet to be determined. This narrative review provides an overview of the role of self-efficacy in exercise adherence in CHF. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Self-care and depression in patients with chronic heart failure.
Holzapfel, Nicole; Löwe, Bernd; Wild, Beate; Schellberg, Dieter; Zugck, Christian; Remppis, Andrew; Katus, Hugo A; Haass, Markus; Rauch, Bernhard; Jünger, Jana; Herzog, Wolfgang; Müller-Tasch, Thomas
2009-01-01
Although chronic heart failure (CHF) is often complicated by comorbid depression and poor self-care, little is known about their specific association in patients with CHF. To investigate self-care behavior among patients with CHF with different degrees of depression severity. A total of 287 patients with documented CHF, New York Heart Association functional class II to IV, completed the European Heart Failure Self-Care Behavior Scale. The Structured Clinical Interview for DSM (SCID) IV served as the criterion standard for the presence of a depressive disorder. Analyses of covariance and linear regression analyses revealed that patients with CHF with minor depression reported significantly lower levels of self-care than patients with major depression (P = .003) and nondepressed patients (P = .014). In addition to minor depression, age (P < or = .001), multimorbidity (P = .01), left ventricular ejection fraction (P = .001), and family status (P = .01) were determinants of self-care. Our results demonstrate that patients with CHF with minor depression and not major depression are at higher risk for poor self-care and its resulting consequences, such as symptom deterioration and frequent hospitalization.
Experimental investigation on premature occurrence of critical heat flux under oscillatory flow
International Nuclear Information System (INIS)
Vishnoi, A.K.; Dasgupta, A.; Chandraker, D.K.; Nayak, A.K.; Rama Rao, A.; Hegde, Nandan D.
2016-01-01
Two-phase natural circulation loops have extensive applications in nuclear and process industries. One of the major concerns with natural circulation is the occurrence of the various types of flow instabilities, which can cause premature boiling crisis due to flow and power oscillations. In this work, experimental investigation on CHF under oscillatory flow was carried out in a facility named CHF and Instability Loop (CHIL). CHIL is a simple rectangular loop having a 10.5 mm ID and 1.1 m long test section. The flow through the test section is controlled by a canned motor pump using a Variable Frequency Drive (VFD). The effect of frequency and amplitude of flow oscillation on occurrence of premature CHF has been investigated for this facility using a transient computer code COPCOS (Code for Prediction of CHF under Oscillating flow and power condition). The code incorporates conduction equation of the fuel and coolant energy equation. For CHF prediction, CHF look-up table developed by Groeneveld is used. Full paper covers description of the facility, experimental procedure, experimental results and data analysis using COPCOS. (author)
Directory of Open Access Journals (Sweden)
Renato De Vecchis
2016-10-01
Full Text Available In the congestive heart failure (CHF setting, chronic hyponatremia is very common. The present review aims at addressing topics relevant to the pathophysiology of hyponatremia in the course of CHF as well as its optimal treatment, including the main advantages and the limitations resulting from the use of the available dietary and pharmacological measures approved for the treatment of this electrolytic trouble. A narrative review is carried out in order to represent the main modalities of therapy for chronic hyponatremia that frequently complicates CHF. The limits of usual therapies implemented for CHF-related chronic hyponatremia are outlined, while an original analysis of the main advancements achieved with the use of vasopressin receptor antagonists (VRAs is also executed. The European regulatory restrictions that currently limit the use of VRAs in the management of CHF are substantially caused by financial concerns, i.e., the high costs of VRA therapy. A thoughtful reworking of current restrictions would be warranted in order to enable VRAs to be usefully associated to loop diuretics for decongestive treatment of CHF patients with hyponatremia.
Association du personnel
2012-01-01
Special discount to the members of the Staff Association Aquaparc Discounted prices on admission of whole day. Children from 5 to 15 years: 26.– CHF instead of 35.– CHF; Adults from 16 years: 32.– CHF instead of 43.– CHF.Tickets on sale to the Staff Association Secretariat. BCGE Account management on salary account and annual subscription to credit cards free of charge. Other benefits on mortgage loan and financial planning. Comédie de Genève 20% off on full price tickets (also available for partner): from 24 to 32 CHF a ticket instead of 30 to 40 CHF depending on the shows. Ezee Suisse 15% off on the range of electric bikes upon presentation of your Staff Association membership card before payment. FNAC 5% discount on gifts card available in four Swiss shops without any restriction. Gifts card on sale to the Staff Association Secretariat. FutureKids 15% off for the Staff Association members who enrol their children of 5 to 16 years old in ...
Energy Technology Data Exchange (ETDEWEB)
Corradini, Michael [Univ. of Wisconsin, Madison, WI (United States); Wu, Qiao [Oregon State Univ., Corvallis, OR (United States)
2015-04-30
This report is a preliminary document presenting an overview of the Critical Heat Flux (CHF) phenomenon, the High Pressure Critical Heat Flux facility (HPCHF), preliminary CHF data acquired, and the future direction of the research. The HPCHF facility has been designed and built to study CHF at high pressure and low mass flux ranges in a rod bundle prototypical of conceptual Small Modular Reactor (SMR) designs. The rod bundle is comprised of four electrically heated rods in a 2x2 square rod bundle with a prototypic chopped-cosine axial power profile and equipped with thermocouples at various axial and circumferential positions embedded in each rod for CHF detection. Experimental test parameters for CHF detection range from pressures of ~80 – 160 bar, mass fluxes of ~400 – 1500 kg/m2s, and inlet water subcooling from ~30 – 70°C. The preliminary data base established will be further extended in the future along with comparisons to existing CHF correlations, models, etc. whose application ranges may be applicable to the conditions of SMRs.
Modeling and forecasting foreign exchange daily closing prices with normal inverse Gaussian
Teneng, Dean
2013-09-01
We fit the normal inverse Gaussian(NIG) distribution to foreign exchange closing prices using the open software package R and select best models by Käärik and Umbleja (2011) proposed strategy. We observe that daily closing prices (12/04/2008 - 07/08/2012) of CHF/JPY, AUD/JPY, GBP/JPY, NZD/USD, QAR/CHF, QAR/EUR, SAR/CHF, SAR/EUR, TND/CHF and TND/EUR are excellent fits while EGP/EUR and EUR/GBP are good fits with a Kolmogorov-Smirnov test p-value of 0.062 and 0.08 respectively. It was impossible to estimate normal inverse Gaussian parameters (by maximum likelihood; computational problem) for JPY/CHF but CHF/JPY was an excellent fit. Thus, while the stochastic properties of an exchange rate can be completely modeled with a probability distribution in one direction, it may be impossible the other way around. We also demonstrate that foreign exchange closing prices can be forecasted with the normal inverse Gaussian (NIG) Lévy process, both in cases where the daily closing prices can and cannot be modeled by NIG distribution.
Directory of Open Access Journals (Sweden)
Guang-ming CHEN
2011-08-01
Full Text Available Objective To explore the effect of continuous hemofiltration(CHF on internal environment and survival rate of severe heatstroke dogs with shock.Methods Sixteen healthy male dogs were randomly divided into heatshock group(HS group,n=8 and continuous hemofiltration group(CHF group,n=8.Severe heatstroke model was established by applying high temperature to whole body,and then the animals were removed from the heating cabin as soon as they presented manifestations of shock.Dogs of HS group were put into an ordinary environment,while dogs of CHF group received CHF treatment.The core temperature(Tc,mean arterial pressure(MAP,blood gas analysis,serum electrolytes and survival rate of dogs in two groups were observed.Results The time from heat exposure to shock was 107.0±28.5min and 111.4±22.2min in HS group and CHF group respectively(t=-0.354,P=0.729.The Tc in CHF group declined to normal level 15 to 30 minitues after CHF treatment,while the Tc in HS group remained at a level higher than that before heat exposure at 90min after shock.The Tc of two groups showed significant difference at each time point after shock(P < 0.01.The MAP of both groups was obviously lowered than that before heatstroke.The MAP of CHF group raised gradually 30 min after treatment,while the MAP of HS group rose very slowly,and it was significantly lower than that of CHF group at each time point after 45min(P < 0.05,P < 0.01.All the dogs in both groups manifested hyperventilation and respiratory alkalosis when shock appeared.After shock,respiratory alkalosis in HS group gradually became metabolic acidosis,with some animals manifested combined metabolic and respiratory acidosis because of respiratory decompensation,while the blood gas levels in CHF group recovered to normal gradually.The blood gas levels of two groups showed significant difference at each time point after shock(P < 0.05,P < 0.01.Hypernatremia,hyperchloraemia and hyperpotassaemia were found in all animals of both
Elephantiasis Nostras Verrucosa (ENV): a complication of congestive heart failure and obesity.
Baird, Drew; Bode, David; Akers, Troy; Deyoung, Zachariah
2010-01-01
Congestive heart failure (CHF) and obesity are common medical conditions that have many complications and an increasing incidence in the United States. Presented here is a case of a disfiguring skin condition that visually highlights the dermatologic consequences of poorly controlled CHF and obesity. This condition will probably become more common as CHF and obesity increase in the US.
Energy Technology Data Exchange (ETDEWEB)
Greenwood, M.S., E-mail: 1greenwoodms@ornl.gov; Duarte, J.P.; Corradini, M.
2017-06-15
Highlights: • Low mass flux and moderate to high pressure CHF experimental results are presented. • Facility uses chopped-cosine heater profile in a 2 × 2 square bundle geometry. • The EPRI, CISE-GE, and W-3 CHF correlations provide reasonable average CHF prediction. • Neural network analysis predicts experimental data and demonstrates utility of method. - Abstract: The critical heat flux (CHF) is a two-phase flow phenomenon which rapidly decreases the efficiency of the heat transfer performance at a heated surface. This phenomenon is one of the limiting criteria in the design and operation of light water reactors. Deviations of operating parameters greatly alters the CHF condition and must be experimentally determined for any new parameters such as those proposed in small modular reactors (SMR) (e.g. moderate to high pressure and low mass fluxes). Current open literature provides too little data for functional use at the proposed conditions of prototypical SMRs. This paper presents a brief summary of CHF data acquired from an experimental facility at the University of Wisconsin-Madison designed and built to study CHF at high pressure and low mass flux ranges in a 2 × 2 chopped cosine rod bundle prototypical of conceptual SMR designs. The experimental CHF test inlet conditions range from pressures of 8–16 MPa, mass fluxes of 500–1600 kg/m2 s, and inlet water subcooling from 250 to 650 kJ/kg. The experimental data is also compared against several accepted prediction methods whose application ranges are most similar to the test conditions.
Improvement of boiling heat transfer by radiation induced boiling enhancement
International Nuclear Information System (INIS)
Imai, Yasuyuki; Okamoto, Koji; Madarame, Haruki; Takamasa, Tomoji
2003-01-01
For nuclear reactor systems, the critical heat flux (CHF) data is very important because it limits reactor efficiency. Improvement of CHF requires that the cooling liquid can contact the heating surface, or a high-wettability, highly hydrophilic heating surface, even if a vapor bubble layer is generated on the surface. In our previous study, we confirmed that the surface wettability changed significantly or that highly hydrophilic conditions were achieved, after irradiation of 60 Co gamma ray, by the Radiation Induced Surface Activation (RISA) phenomenon. To delineate the effect of RISA on boiling phenomena, surface wettability in a high-temperature environment and critical heat flux (CHF) of metal oxides irradiated by gamma rays were investigated. A CHF experiment in the pool boiling condition was carried out under atmospheric pressure. The heating test section made of titanium was 0.2 mm in thickness, 3 mm in height, and 60 mm in length. Oxidation of the surface was carried out by plasma jetting for 40 seconds. The test section was irradiated by 60 Co gamma ray with predetermined radiation intensity and period. The CHF of oxidized titanium was improved up to 100 percent after 800 kGy 60 Co gamma ray irradiation. We call this effect Radiation Induced Boiling Enhancement (RIBE). Before we conducted the CHF experiment, contact angles of the test pieces were measured to show the relationship between wettability and CHF. The CHF in the present experiment increases will surface wettability in the same manner as shown by Liaw and Dhir's results. (author)
Improvement of boiling heat transfer by radiation induced boiling enhancement
International Nuclear Information System (INIS)
Imai, Y.; Okamoto, K.; Madarame, H.; Takamasa, T.
2003-01-01
For nuclear reactor systems, the Critical Heat Flux (CHF) data is very important because it limits reactor efficiency. Improvement of CHF requires that the cooling liquid can contact the heating surface, or a high-wettability, highly hydrophilic heating surface, even if a vapor bubble layer is generated on the surface. In our previous study, we confirmed that the surface wettability changed significantly or that highly hydrophilic conditions were achieved, after irradiation of 60Co gamma ray, by the Radiation Induced Surface Activation (RISA) phenomenon. To delineate the effect of RISA on boiling phenomena, surface wettability in a high-temperature environment and Critical Heat Flux (CHF) of metal oxides irradiated by gamma rays were investigated. A CHF experiment in the pool boiling condition was carried out under atmospheric pressure. The heating test section made of titanium was 0.2mm in thickness, 3mm in height, and 60mm in length. Oxidation of the surfaces was carried out by plasma jetting for 40 seconds. The test section was irradiated by 60Co gamma ray with predetermined radiation intensity and period. The CHF of oxidized titanium was improved up to 100 percent after 800kGy 60Co gamma ray irradiation. We call this effect Radiation Induced Boiling Enhancement (RIBE). Before we conducted the CHF experiment, contact angles of the test pieces were measured to show the relationship between wettability and CHF. The CHF in the present experiment increases with surface wettability in the same manner as shown by Liaw and Dhir's results
Critical heat flux in a vertical annulus under low upward flow and near atmospheric pressure
International Nuclear Information System (INIS)
Schoesse, T.; Aritomi, Masanori; Lee, Sang-Ryoul; Kataoka, Yoshiaki; Yoshioka, Yuzuru; Chung, Moon-Ki.
1997-01-01
As future boiling water reactors (BWR), concepts of evolutional ABWR (ABWR-IER) and natural circulation BWR (JSBWR) have been investigated in order to reduce their construction cost and simplify their maintenance and inspection procedures. One of the promised features of the design of the evolutional ABWR is to reduce the number of internal pumps and to remove the Motor Generation (MG) sets. These design changes may induce boiling transition in the fuel rods of reactor core during a pump trip transient due to the more rapid flow coastdown characteristics than these of the present design. In addition, the understanding of critical heat flux (CHF) is one important subject to grasp safety margin during the start-up for the natural circulation BWR and to establish the rational start-up procedure in which thermo-hydraulic instabilities can be suppressed. The present study is to clarify CHF characteristics under low velocity conditions. CHF measurements were conducted in a vertical upward annulus channel composed of an inner heated rod and an outer tube made of glass. CHF data were obtained repeatedly under the condition of stable inlet flow to examine statistically their reproducibility. The flow regime was investigated from flow observation and measurement of differential pressure fluctuation. The CHF data are correlated with the flow regime transition. It was clear from the obtained flow pattern and the CHF data that the CHF behavior could be classified into specified regions by the mass flux and inlet subcooling conditions. A CHF correlation was developed and agreed with other researchers' data within acceptable error. (author)
AGXT2 rs37369 polymorphism predicts the renal function in patients with chronic heart failure.
Hu, Xiao-Lei; Zeng, Wen-Jing; Li, Mu-Peng; Yang, Yong-Long; Kuang, Da-Bin; Li, He; Zhang, Yan-Jiao; Jiang, Chun; Peng, Li-Ming; Qi, Hong; Zhang, Ke; Chen, Xiao-Ping
2017-12-30
Patients with chronic heart failure (CHF) are often accompanied with varying degrees of renal diseases. The purpose of this study was to identify rs37369 polymorphism of AGXT2 specific to the renal function of CHF patients. A total of 1012 southern Chinese participants, including 487 CHF patients without history of renal diseases and 525 healthy volunteers, were recruited for this study. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) was used to determine the genotypes of AGXT2 rs37369 polymorphism. Levels of blood urea nitrogen (BUN) and serum creatinine (SCr) were detected to indicate the renal function of the participants. BUN level was significantly higher in CHF patients without history of renal diseases compared with healthy volunteers (p=0.000). And the similar result was also obtained for SCr (p=0.000). Besides, our results indicated that the level of BUN correlated significantly with SCr in both the CHF patients without renal diseases (r=0.4533, prenal diseases (p=0.036, AA+AG vs GG). Patients with rs37369 GG genotype showed a significantly reduced level of BUN compared to those with the AA genotype (p=0.024), and the significant difference was still observed in the smokers of CHF patients without renal diseases (p=0.023). In conclusion, we found that CHF might induce the impairment of kidney and cause deterioration of renal function. AGXT2 rs37369 polymorphism might affect the renal function of CHF patients free from renal diseases, especially in patients with cigarette smoking. Copyright © 2017. Published by Elsevier B.V.
An update to the multitasking thermalhydraulics evaluation package
Energy Technology Data Exchange (ETDEWEB)
Guo, Y.; Leung, L.K.H.; Vasic, A. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)
2007-07-01
An update of the multitasking Thermalhydraulics Evaluation Package (TEP) was implemented to improve the prediction accuracy of critical heat flux (CHF) and post-dryout (PDO) heat transfer for 37-element fuel bundles. The improvement of prediction accuracy was achieved using the latest correlations for CHF and PDO heat transfer derived from fullscale bundle tests. The predictions of TEP were assessed against experimental data and good agreement has been observed. In addition to the improvement, the prediction capability of the package has been expanded to capture the effect of radial power profile on CHF for 37-element bundles. A correlation for the radial power profile effect on CHF has been implemented. It accounts for the deviation in CHF between the bundle of radial power profile of interest and the equivalent bundle of the natural uranium profile. (author)
Diameter effect on critical heat flux
International Nuclear Information System (INIS)
Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.
2009-01-01
The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods
Varadarajan, Padmini; Gandhi, Siddharth; Sharma, Sanjay; Umakanthan, Branavan; Pai, Ramdas G
2006-10-01
Previous studies have shown low hemoglobin (Hb) to have an adverse effect on survival in patients with congestive heart failure (CHF) and reduced left ventricular (LV) ejection fraction (EF); but its effect on survival in patients with CHF and normal EF is not known. This study sought to determine whether low Hb has an effect on survival in patients with both CHF and normal EF. Detailed chart reviews were performed by medical residents on 2,246 patients (48% with normal EF) with a discharge diagnosis of CHF in a large tertiary care hospital from 1990 to 1999. The CHF diagnosis was validated using the Framingham criteria. Mortality data were obtained from the National Death Index. Survival analysis was performed using Kaplan-Meier and Cox regression models. By Kaplan-Meier analysis, low Hb (< 12 gm/dl) compared with normal hemoglobin was associated with a lower 5-year survival in patients with CHF and both normal (38 vs. 50%, p = 0.0008) and reduced (35 vs. 48%, p = 0.0009) EF. Using the Cox regression model, low Hb was an independent predictor of mortality after adjusting for age, gender, renal dysfunction, diabetes mellitus, hypertension, and EF in both groups of patients. Low Hb has an independent adverse effect on survival in patients with CHF and both normal and reduced EF in both groups of patients.
Pügge, Carolin; Mediratta, Jai; Marcus, Noah J; Schultz, Harold D; Schiller, Alicia M; Zucker, Irving H
2016-02-01
Recent data suggest that exercise training (ExT) is beneficial in chronic heart failure (CHF) because it improves autonomic and peripheral vascular function. In this study, we hypothesized that ExT in the CHF state ameliorates the renal vasoconstrictor responses to hypoxia and that this beneficial effect is mediated by changes in α1-adrenergic receptor activation. CHF was induced in rabbits. Renal blood flow (RBF) and renal vascular conductance (RVC) responses to 6 min of 5% isocapnic hypoxia were assessed in the conscious state in sedentary (SED) and ExT rabbits with CHF with and without α1-adrenergic blockade. α1-adrenergic receptor expression in the kidney cortex was also evaluated. A significant decline in baseline RBF and RVC and an exaggerated renal vasoconstriction during acute hypoxia occurred in CHF-SED rabbits compared with the prepaced state (P renal denervation (DnX) blocked the hypoxia-induced renal vasoconstriction in CHF-SED rabbits. α1-adrenergic protein in the renal cortex of animals with CHF was increased in SED animals and normalized after ExT. These data provide evidence that the acute decline in RBF during hypoxia is caused entirely by the renal nerves but is only partially mediated by α1-adrenergic receptors. Nonetheless, α1-adrenergic receptors play an important role in the beneficial effects of ExT in the kidney. Copyright © 2016 the American Physiological Society.
Tu, Huiyin; Liu, Jinxu; Zhu, Zhen; Zhang, Libin; Pipinos, Iraklis I; Li, Yu-Long
2012-01-01
Our previous study has shown that chronic heart failure (CHF) reduces expression and activation of voltage-gated sodium (Na(v)) channels in baroreceptor neurons, which are involved in the blunted baroreceptor neuron excitability and contribute to the impairment of baroreflex in the CHF state. The present study examined the role of mitochondria-derived superoxide in the reduced Na(v) channel function in coronary artery ligation-induced CHF rats. CHF decreased the protein expression and activity of mitochondrial complex enzymes and manganese SOD (MnSOD) and elevated the mitochondria-derived superoxide level in the nodose neurons compared with those in sham nodose neurons. Adenoviral MnSOD (Ad.MnSOD) gene transfection (50 multiplicity of infection) into the nodose neurons normalized the MnSOD expression and reduced the elevation of mitochondrial superoxide in the nodose neurons from CHF rats. Ad.MnSOD also partially reversed the reduced protein expression and current density of the Na(v) channels and the suppressed cell excitability (the number of action potential and the current threshold for inducing action potential) in aortic baroreceptor neurons from CHF rats. Data from the present study indicate that mitochondrial dysfunction, including decreased protein expression and activity of mitochondrial complex enzymes and MnSOD and elevated mitochondria-derived superoxide, contributes to the reduced Na(v) channel activation and cell excitability in the aortic baroreceptor neurons in CHF rats.
Muus, Kyle J; Knudson, Alana; Klug, Marilyn G; Gokun, Jane; Sarrazin, Mary; Kaboli, Peter
2010-01-01
Hospital re-admissions for patients with congestive heart failure (CHF) are relatively common and costly occurrences within the US health infrastructure, including the Veterans Affairs (VA) healthcare system. Little is known about CHF re-admissions among rural veteran patients, including the effects of socio-demographics and follow-up outpatient visits on these re-admissions. To examine socio-demographics of US veterans with CHF who had 30 day potentially preventable re-admissions and compare the effect of 30 day VA post-discharge service use on these re-admissions for rural- and urban-dwelling veterans. The 2005-2007 VA data were analyzed to examine patient characteristics and hospital admissions for 36 566 veterans with CHF. The CHF patients who were and were not re-admitted to a VA hospital within 30 days of discharge were identified. Logistic regression was used to examine and compare the effect of VA post-acute service use on re-admissions between rural- and urban-dwelling veterans. Re-admitted veterans tended to be older (p=.002), had disability status (p=.024) and had longer hospital stays (precovery and good health among hospitalized veterans with CHF, regardless of their rural or urban residence. Older, rural veterans with CHF are in need of special attention for VA discharge planning and follow up with primary care providers.
An analysis of critical heat flux on the external surface of the reactor vessel lower head
International Nuclear Information System (INIS)
Yang, Soo Hyung; Baek, Won Pil; Chang, Soon Heung
1999-01-01
CHF (Critical heat flux) on the external surface of the reactor vessel lower head is major key in the evaluation on the feasibility of IVR-EVC (In-Vessel Retention through External Vessel Cooling) concept. To identify the CHF on the external surface, considerable works have been performed. Through the review on the previous works related to the CHF on the external surface, liquid subcooling, induced flow along the external surface, ICI (In-Core Instrument) nozzle and minimum gap are identified as major parameters. According to the present analysis, the effects of the ICI nozzle and minimum gap on CHF are pronounced at the upstream of test vessel: on the other hand, the induced flow considerably affects the CHF at downstream of test vessel. In addition, the subcooling effect is shown at all of test vessel, and decreases with the increase in the elevation of test vessel. In the real application of the IVR-EVC concept, vertical position is known as a limiting position, at which thermal margin is the minimum. So, it is very important to precisely predict the CHF at vertical position in a viewpoint of gaining more thermal margins. However, the effects of the liquid subcooling and induced flow do not seem to be adequately included in the CHF correlations suggested by previous works, especially at the downstream positions
van Lieshout, Jan; Steenkamer, Betty; Knippenberg, Marjan; Wensing, Michel
2011-03-25
Many patients with chronic heart failure (CHF), a common condition with high morbidity and mortality rates, receive treatment in primary care. To improve the management of CHF in primary care, we developed an implementation programme comprised of educational and organisational components, with support by a practice visitor and focus both on drug treatment and lifestyle advice, and on organisation of care within the practice and collaboration with other healthcare providers. Tailoring has been shown to improve the success of implementation programmes, but little is known about what would be best methods for tailoring, specifically with respect to CHF in primary care. We describe the study protocol of a cluster randomised controlled trial to examine the effectiveness of tailoring a CHF implementation programme to general practices compared to a standardised way of delivering a programme. The study population will consist of 60 general practitioners (GPs) and the CHF patients they include. GPs are randomised in blocks of four, stratified according to practice size. With a tailored implementation programme GPs prioritise the issues that will form the bases of the support for the practice visits. These may comprise several issues, both educational and organizational.The primary outcome measures are patient's experience of receiving structured primary care for CHF (PACIC, a questionnaire related to the Chronic Care Model), patients' health-related utilities (EQ-5D), and drugs prescriptions using the guideline adherence index. Patients being clustered in practices, multilevel regression analyses will be used to explore the effect of practice size and type of intervention programme. In addition we will examine both changes within groups and differences at follow-up between groups with respect to drug dosages and advice on lifestyle issues. Furthermore, in interviews the feasibility of the programme and goal attainment, organisational changes in CHF care, and formalised
Directory of Open Access Journals (Sweden)
Wensing Michel
2011-03-01
Full Text Available Abstract Background Many patients with chronic heart failure (CHF, a common condition with high morbidity and mortality rates, receive treatment in primary care. To improve the management of CHF in primary care, we developed an implementation programme comprised of educational and organisational components, with support by a practice visitor and focus both on drug treatment and lifestyle advice, and on organisation of care within the practice and collaboration with other healthcare providers. Tailoring has been shown to improve the success of implementation programmes, but little is known about what would be best methods for tailoring, specifically with respect to CHF in primary care. Methods/design We describe the study protocol of a cluster randomised controlled trial to examine the effectiveness of tailoring a CHF implementation programme to general practices compared to a standardised way of delivering a programme. The study population will consist of 60 general practitioners (GPs and the CHF patients they include. GPs are randomised in blocks of four, stratified according to practice size. With a tailored implementation programme GPs prioritise the issues that will form the bases of the support for the practice visits. These may comprise several issues, both educational and organizational. The primary outcome measures are patient's experience of receiving structured primary care for CHF (PACIC, a questionnaire related to the Chronic Care Model, patients' health-related utilities (EQ-5D, and drugs prescriptions using the guideline adherence index. Patients being clustered in practices, multilevel regression analyses will be used to explore the effect of practice size and type of intervention programme. In addition we will examine both changes within groups and differences at follow-up between groups with respect to drug dosages and advice on lifestyle issues. Furthermore, in interviews the feasibility of the programme and goal attainment
Franchising jako metoda vstupu na trh
Smejkal, Martin
2011-01-01
This bachelor thesis focuses on franchising as a form of market entry.The aim of this thesis is to describe franchising as a efficient way of cooperating on theoretical and practical basis. The first chapter describes franchising as a form of cooperation and what are the basic principles of the relation between franchisor and franchisee. History and basic types of franchising are described as well. The second chapter describes a process of forming particular franchise business and what is the...
PRIMENA PLIOMETRIJSKOG METODA TRENINGA U ODBOJCI
Directory of Open Access Journals (Sweden)
Vladan Milić
2011-09-01
Full Text Available Knowledge in various fields of science and the profession is gained from different written information sources today. Their quality is directly dependent on ability to further educate the reader and therefore improve the existing level of knowledge about certain phenomena. The study presents a systematic review and analysis of previous studies, published in the last twenty years, on the application of plyometric training method in volleyball. A descriptive and historical methods are used, and data source are different electronic articles appropriate to the topic, as well as printed literature. Plyometric method and its application in practice, even today, causes a lot of controversy among experts and researchers, and therefore cannot make a unique conclusion. However, experts have agreed that the application of plyometric training method in volleyball can achieve the effects of applying this method, primarily to improve the vertical jump and vertical jump in volleyball.
Franchising jako metoda vstupu na trh
Grešlová, Denisa
2011-01-01
Purpose of entered final thesis is to explain function of franchising, describe main principls, advantages and disadvantages. From summarized basic information to analyze specific case of franchising concept "Potrefená husa" from brewery Pivovary Staropramen a.s.
Franchising jako metoda vstupu na trh
Knapová, Monika
2011-01-01
This bachelor thesis describes franchising as an method of entry to the market. The first part defines basic terms, the history of franchising, advantages and disadvantages of franchising, it describes the way how to start franchising business and its development in the Czech Republic. The second part describes a banking system UniCredit Bank.
Franchising jako metoda vstupu na trh
Tichá, Alice
2011-01-01
There are several alternatives to entering a new business market. This bachelor thesis focuses on franchising as one form of market entry. Both the theoretical and practical aspects of franchising will be discussed. The theoretical section encompasses the basic principles of franchising, its history and conception. All aspects of franchising, including the advantages and disadvantages for both franchisor and franchisee, will be reviewed. The practical section focuses on franchising applied to...
Wenchi Jin; Hong S. He; Frank R. Thompson; Wen J. Wang; Jacob S. Fraser; Stephen R. Shifley; Brice B. Hanberry; William D. Dijak
2017-01-01
The Central Hardwood Forest (CHF) in the United States is currently a major carbon sink, there are uncertainties in how long the current carbon sink will persist and if the CHF will eventually become a carbon source. We used a multi-model ensemble to investigate aboveground carbon density of the CHF from 2010 to 2300 under current climate. Simulations were done using...
International Nuclear Information System (INIS)
Zhou Tao; Su Guanghui; Liao Yixiang; Zhang Weizhong; Qiu Suizheng; Jia Dounan
1999-12-01
Using grey systems theory and experimental data obtained from sodium boiling test loop in China, grey mutual analysis is done to some parameters influencing sodium CHF. The results of CHF are predicted by using GM (1,1) model. The GM(1,h) model is made up for creating CHF model. The results are in good agreement with the experimental data
Correlation of critical heat flux data for uniform tubes
Energy Technology Data Exchange (ETDEWEB)
Jafri, T.; Dougherty, T.J.; Yang, B.W. [Columbia Univ., New York, NY (United States)
1995-09-01
A data base of more than 10,000 critical heat flux (CHF) data points has been compiled and analyzed. Two regimes of CHF are observed which will be referred to as the high CHF regime and the low CHF regime. In the high CHF regime, for pressures less than 110 bar, CHF (q{sub c}) is a determined by local conditions and is adequately represented by q{sub c} = (1.2/D{sup 1/2}) exp[-{gamma}(GX{sub t}){sup 1/2}] where the parameter {gamma} is an increasing function of pressure only, X{sub t} the true mass fraction of steam, and all units are metric but the heat flux is in MWm{sup -2}. A simple kinetic model has been developed to estimate X{sub t} as a function of G, X, X{sub i}, and X{sub O}, where X{sub i} is the inlet quality and X{sub O} represents the quality at the Onset of Significant Vaporization (OSV) which is estimated from the Saha-Zuber (S-Z) correlation. The model is based on a rate equation for vaporization suggested by, and consistent with, the S-Z correlation and contains no adjustable parameters. When X{sub i}
Wang, Han-Jun; Cahoon, Rebecca; Cahoon, Edgar B; Zheng, Hong; Patel, Kaushik P; Zucker, Irving H
2015-03-01
Excitatory amino acids (e.g., glutamate) released by contraction-activated skeletal muscle afferents into the dorsal horn of the spinal cord initiate the central component of the exercise pressor reflex (EPR) in physiological conditions. However, the role of glutamate and glutamate receptors in mediating the exaggerated EPR in the chronic heart failure (CHF) state remains to be determined. In the present study, we performed microinjection of glutamate receptor antagonists into ipisilateral L4/L5 dorsal horns to investigate their effects on the pressor response to static contraction induced by stimulation of the peripheral end of L4/L5 ventral roots in decerebrate sham-operated (sham) and CHF rats. Microinjection of glutamate (10 mM, 100 nl) into the L4 or L5 dorsal horn caused a greater pressor response in CHF rats compared with sham rats. Furthermore, microinjection of either the broad-spectrum glutamate receptor antagonist kynurenate (10 mM, 100 nl) or the N-methyl-d-aspartate (NMDA) receptor antagonist dl-2-amino-5-phosphonovalerate (50 mM, 100 nl) or the non-NMDA-sensitive receptor antagonist 6-cyano-7-nitroquinoxaline-2,3-dione (5 mM, 100 nl) into L4/5 dorsal horns decreased the pressor response to static contraction in CHF rats to a greater extent than in sham rats. Molecular evidence showed that the protein expression of glutamate receptors (both non-NMDA and NMDA) was elevated in the dorsal horn of the lumbar spinal cord in CHF rats. In addition, data from microdialysis experiments demonstrated that although basal glutamate release at the dorsal horn at rest was similar between sham and CHF rats (225 ± 50 vs. 260 ± 63 nM in sham vs. CHF rats, n = 4, P > 0.05), CHF rats exhibit greater glutamate release into the dorsal horn during muscle contraction compared with sham rats (549 ± 60 vs. 980 ± 65 nM in sham vs. CHF rats, n = 4, P < 0.01). These data indicate that the spinal glutamate system contributes to the exaggerated EPR in the CHF state. Copyright
Directory of Open Access Journals (Sweden)
Р. P. Bidzilya
2016-08-01
Full Text Available Recently clinical studies demonstrated reciprocal association between traditional cardiovascular risk factors, in particular, hyperlipidemia and obesity, with worse clinical outcomes in CHF. Unlike ischemic heart disease (IHD, where high levels of atherogenic and low of antiatherogenic lipids fraction traditionally associated with worsening of prognosis and course of disease, in conditions of the CHF proven negative impact of the reduction of lipid levels and body mass index. Demonstrated the phenomena called "cholesterol paradox" and "obesity paradox". Aim. To study the features of lipid metabolism in CHF of different genesis with concomitant overweight and obesity. Materials and methods. 240 patients with I–III functional class (FC of the disease with concomitant overweight and abdominal obesity I–III degree were examined. FC of the disease was established according to the classification of New York Heart Association (NYHA.Normal, overweight and the degree of abdominal obesity was identified by calculating the body mass index. Etiologic factors of CHF were chronic forms of IHD, arterial hypertension, and/or a combination of both. With the help of biochemical blood tests lipid metabolism were assessed. Results. The maximum values as atherogenic and antiatherogenic lipid indicators are investigated in non-ischemic (hypertensive CHF. Patients with CHF of ischemic genesis are characterized by minimal values of atherogenic fractions of lipids. Patients with combined etiology of CHF occupy the intermediate position of atherogenic fractions content, while they demonstrate the minimum value in the antiatherogenic HDL-cholesterol. Conclusion. Changes of lipid metabolism are varied depending on the etiology of CHF in patients with concomitant overweight and obesity and the most unfavorable in ischemic form of the disease.
Mehra, Tarun; Koljonen, Virve; Seifert, Burkhardt; Volbracht, Jörk; Giovanoli, Pietro; Plock, Jan; Moos, Rudolf Maria
2015-01-01
Reimbursement systems have difficulties depicting the actual cost of burn treatment, leaving care providers with a significant financial burden. Our aim was to establish a simple and accurate reimbursement model compatible with prospective payment systems. A total of 370 966 electronic medical records of patients discharged in 2012 to 2013 from Swiss university hospitals were reviewed. A total of 828 cases of burns including 109 cases of severe burns were retained. Costs, revenues and earnings for severe and nonsevere burns were analysed and a linear regression model predicting total inpatient treatment costs was established. The median total costs per case for severe burns was tenfold higher than for nonsevere burns (179 949 CHF [167 353 EUR] vs 11 312 CHF [10 520 EUR], interquartile ranges 96 782-328 618 CHF vs 4 874-27 783 CHF, p <0.001). The median of earnings per case for nonsevere burns was 588 CHF (547 EUR) (interquartile range -6 720 - 5 354 CHF) whereas severe burns incurred a large financial loss to care providers, with median earnings of -33 178 CHF (30 856 EUR) (interquartile range -95 533 - 23 662 CHF). Differences were highly significant (p <0.001). Our linear regression model predicting total costs per case with length of stay (LOS) as independent variable had an adjusted R2 of 0.67 (p <0.001 for LOS). Severe burns are systematically underfunded within the Swiss reimbursement system. Flat-rate DRG-based refunds poorly reflect the actual treatment costs. In conclusion, we suggest a reimbursement model based on a per diem rate for treatment of severe burns.
Two-phase flow regimes and mechanisms of critical heat flux under subcooled flow boiling conditions
International Nuclear Information System (INIS)
Le Corre, Jean-Marie; Yao, Shi-Chune; Amon, Cristina H.
2010-01-01
A literature review of critical heat flux (CHF) experimental visualizations under subcooled flow boiling conditions was performed and systematically analyzed. Three major types of CHF flow regimes were identified (bubbly, vapor clot and slug flow regime) and a CHF flow regime map was developed, based on a dimensional analysis of the phenomena and available experimental information. It was found that for similar geometric characteristics and pressure, a Weber number (We)/thermodynamic quality (x) map can be used to predict the CHF flow regime. Based on the experimental observations and the review of the available CHF mechanistic models under subcooled flow boiling conditions, hypothetical CHF mechanisms were selected for each CHF flow regime, all based on a concept of wall dry spot overheating, rewetting prevention and subsequent dry spot spreading. Even though the selected concept has not received much attention (in term or theoretical developments and applications) as compared to other more popular DNB models, its basis have often been cited by experimental investigators and is considered by the authors as the 'most-likely' mechanism based on the literature review and analysis performed in this work. The selected modeling concept has the potential to span the CHF conditions from highly subcooled bubbly flow to early stage of annular flow and has been numerically implemented and validated in bubbly flow and coupled with one- and three-dimensional (CFD) two-phase flow codes, in a companion paper. [Le Corre, J.M., Yao, S.C., Amon, C.H., in this issue. A mechanistic model of critical heat flux under subcooled flow boiling conditions for application to one and three-dimensional computer codes. Nucl. Eng. Des.].
Silverberg, Donald S
2011-11-01
Anemia is common in Congestive Heart Failure (CHF) and is associated with an increased mortality, morbidity and progressive renal failure. The most common causes of the anemia in CHF are (1) the associated Chronic Kidney Disease (CKD), which causes depression of erythropoietin (EPO) production in the kidney, and (2) excessive cytokine production in CHF, which can cause both depression of erythropoietin production in the kidney and depression of erythropoietin response in the bone marrow. The cytokines can also induce iron deficiency by increasing hepcidin production from the liver, which both reduces gastrointestinal iron absorption and reduces iron release from iron stores located in the macrophages and hepatocytes. It appears that iron deficiency is very common in CHF and is rarely recognized or treated. The iron deficiency can cause a thrombocytosis that might contribute to cardiovascular complications in both CHF and CKD and is reversible with iron treatment. Thus, attempts to control this anemia in CHF will have to take into consideration both the use of both Erythropoiesis Stimulating Agents (ESA) such as EPO and oral and, probably more importantly, intravenous (IV) iron. Many studies of anemia in CHF with ESA and oral or IV iron and even with IV iron without ESA have shown a positive effect on hospitalization, New York Heart Association functional class, cardiac and renal function, quality of life, exercise capacity and reduced Beta Natriuretic Peptide and have not demonstrated an increase in cardiovascular damage related to the therapy. However, adequately powered long-term placebo-controlled studies of ESA and of IV iron in CHF are still needed and are currently being carried out.
CFD simulation on critical heat flux of flow boiling in IVR-ERVC of a nuclear reactor
Energy Technology Data Exchange (ETDEWEB)
Zhang, Xiang, E-mail: zhangxiang3@snptc.com.cn [State Nuclear Power Technology Research & Development Center, South Area, Future Science and Technology Park, Chang Ping District, Beijing 102209 (China); Hu, Teng [State Nuclear Power Technology Research & Development Center, South Area, Future Science and Technology Park, Chang Ping District, Beijing 102209 (China); Chen, Deqi, E-mail: chendeqi@cqu.edu.cn [Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, 400044 (China); Zhong, Yunke; Gao, Hong [Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University, 400044 (China)
2016-08-01
Highlights: • CFD simulation on CHF of boiling two-phase flow in ERVC is proposed. • CFD simulation result of CHF agrees well with that of experimental result. • The characteristics of boiling two-phase flow and boiling crisis are analyzed. - Abstract: The effectiveness of in-vessel retention (IVR) by external reactor vessel cooling (ERVC) strongly depends on the critical heat flux (CHF). As long as the local CHF does not exceed the local heat flux, the lower head of the pressure vessel can be cooled sufficiently to prevent from failure. In this paper, a CFD simulation is carried out to investigate the CHF of ERVC. This simulation is performed by a CFD code fluent couple with a boiling model by UDF (User-Defined Function). The experimental CHF of ERVC obtained by State Nuclear Power Technology Research and Development Center (SNPTRD) is used to validate this CFD simulation, and it is found that the simulation result agrees well with the experimental result. Based on the CFD simulation, detailed analysis focusing on the pressure distribution, velocity distribution, void fraction distribution, heating wall temperature distribution are proposed in this paper.
Directory of Open Access Journals (Sweden)
I.I. Vyshnyvetskyy
2016-03-01
Full Text Available Aim. To evaluate the impact of comorbid chronic heart failure (CHF on the severity of symptoms and correctness of chronic obstructive pulmonary disease (COPD classification. Materials and methods. Cross-sectional study included 177 patients with COPD and concomitant cardiovascular diseases. All patients were undergone spirometry, chest radiography, echocardiography, validated questionnaires (COPD assessment test (CAT, Hospital anxiety and depression scale (HADS. Multiple regression was used to establish adjusted impact of CHF presence on CAT scores and COPD severity misclassification. Results. It was established that the presence of comorbid CHF increases CAT score by 3.29, 95% CI [1.71–5.02] points. In the overall cohort of COPD patients CAT scores adjustment for the presence of CHF has resulted in reclassification of 15.5% of patients from group B to group A, and 4.3% of patients from group D to group C. Among selective patients with COPD and CHF the rate of revised classification constituted 32.1% and 7.9%, respectively. Conclusion. The presence of comorbid CHF is able to significantly change the correct assessment of the intensity of COPD symptoms, disease-specific health status and classification of COPD severity.
GPCR-autoantibodies in chronic heart failure.
Boivin-Jahns, Valerie; Jahns, Roland
2018-06-01
Chronic heart failure (CHF) is a syndrome characterized by shortness of breath, fluid retention, and a progressive reduction in cardiac function. More than 60% of the cases are ischemic in origin (i.e., due to myo-cardial infarction) and about 30% are caused by non-ischemic myocardial damage (i.e., due to genetic or non-genetic causes like myocardial inflammation). Because of alterations in both cellular and humoral immunity patients with non-ischemic CHF often develop abnormal or misled immune responses, including cross-reacting antibodies and/or autoantibodies to various cardiac anti-gens. Non-ischemic myo-cardial damage was found to progress to CHF particularly, when associated (a) with the generation of autoantibodies directed against distinct myocyte membrane proteins critically involved in cardiac function - like G-protein coup-led membrane receptors (GPCRs), or (b) with virus persistence in the myocardium. This article will review current knowledge on the pathophysiological relevance of GPCR-autoreactivity in CHF by giving an overview on the so far available evidence from pre-clinical, clinical and epidemiological studies on the CHF-inducing potential of GPCR-autoantibodies and thereon based novel therapeutic approaches in GPCR autoantibody-associated CHF.
Per3 VNTR polymorphism and chronic heart failure.
Lipkova, Jolana; Bienertova-Vasku, Julie Anna; Spinarova, Lenka; Bienert, Petr; Hlavna, Marian; Pavkova Goldbergova, Monika; Parenica, Jiri; Spinar, Jindrich; Vasku, Anna
2014-01-01
The aim of this study was to investigate the relationship between gene Period3 (Per3) variable number tandem repeat (VNTR) polymorphism and chronic heart failure (CHF). The study subjects (372 patients of Caucasian origin with CHF and 332 healthy controls) were genotyped for Per3 VNTR polymorphism using an allele-specific PCR. No significant differences in genotype or Per3 VNTR allele frequencies were found between CHF cases and controls (Pg=0.30, Pa=0.52). No significant differences were uncovered either between CHF cases according to etiology (DCMP vs. IHD; Pg=0.87, Pa=0.91). In the multivariate regression modeling, no predictive function of VNTR Per3 polymorphism on ejection fraction or NYHA class, hyperlipidaemia or type II diabetes risk was found. Per3 VNTR polymorphism is not a major risk factor for chronic heart failure or a factor modulating the severity of the CHF in this population.
nmr spectroscopic study and dft calculations of giao nmr shieldings
African Journals Online (AJOL)
Preferred Customer
3Department of Physics, Arts and Science Faculty, Dumlupinar University, Kütahya, ... 1H, 13C NMR chemical shifts and 1JCH coupling constants of .... then estimated using the corresponding TMS shieldings calculated in advance at the same.
Directory of Open Access Journals (Sweden)
Shinta Rahmalia Irawan
2017-08-01
Full Text Available Cakung-Cilincing Jakarta National Road Section has very rapid traffic load for rigid pavement. The purpose of this study are determining overlay thickness and choosing suitable method for implementation. AASHTO 1993 and AUSTROADS 2011 method are used in this study and using on Falling Weight Deflectometer (FWD data. This study shows that value of Concrete Elasticity Modulus less than 3 million, then this rigid pavement is severely damaged. Based on AASHTO 1993 Method analysis, it needs 11 cm for flexible overlay and 12 cm for rigid overlay on lane 1 with 59% remaining life and lane 2 with 53% remaining life. AUSTROADS 2011 Methods use only FWD data and for overlay thickness determination is use new pavement analysis. Analysis using AUSTROADS 2011 Methods shows that flexible overlay requirement is 24 cm and rigid overlay requirement is 18.50 cm. Comparation between these two methods shows that AASHTO 1993 Method Analysis produce less overlay thickness than AUSTROADS 2011 Methods.
Congestive Heart Failure and Central Sleep Apnea.
Sands, Scott A; Owens, Robert L
2016-03-01
Congestive heart failure (CHF) is among the most common causes of admission to hospitals in the United States, especially in those over age 65. Few data exist regarding the prevalence CHF of Cheyne-Stokes respiration (CSR) owing to congestive heart failure in the intensive care unit (ICU). Nevertheless, CSR is expected to be highly prevalent among those with CHF. Treatment should focus on the underlying mechanisms by which CHF increases loop gain and promotes unstable breathing. Few data are available to determine prevalence of CSR in the ICU, or how CSR might affect clinical management and weaning from mechanical ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.
An experimental study of hypervapotron structure in external reactor vessel cooling
Energy Technology Data Exchange (ETDEWEB)
Zhao, Yufeng; Zhang, Ming [State Nuclear Power Technology R& D Center (Beijing), Beijing (China); Hou, Fangxin [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing (China); Gao, Tianfang [State Nuclear Power Technology R& D Center (Beijing), Beijing (China); Chen, Peipei, E-mail: chenpeipei@snptc.com.cn [State Power Investment Group Corporation, Beijing (China)
2016-07-15
Highlights: • Experiments are performed to study the application of hypervapotron in ERVC design. • CHF experiments on two surfaces are conducted under different flow conditions. • Hypervapotron improves CHF performance by 40–60% compared with smooth surface. • Visualization shows fin structure removes vapor mushroom for better liquid supply. - Abstract: In vessel retention (IVR) is one of the key strategies for many advanced LWR designs to mitigate postulated severe accidents. The success of IVR substantially relies on external reactor vessel cooling (ERVC) by which the decay heat is removed from the melt core in the reactor vessel lower head. The main challenge of IVR is to provide an adequate safety margin of ERVC against critical heat flux (CHF) of subcooled flow boiling in the reactor lower head flow channel. Due to uncertainties in corium melt pool configuration, large CHF margin of ERVC is usually required by regulatory authorities to demonstrate reliability of severe accident mitigation methods. Various CHF enhancement designs have been proposed and studied in literature. In this paper, an experimental study of hypervapotron structure as a novel design to improve CHF performance of ERVC is conducted. Hypervapotron is chosen as one of the potential engineering options for International Thermonuclear Experimental Reactor (ITER) program as a divertor structure to remove highly intense heat from fusion chamber. This study is to conduct CHF experiments at typical PWR ERVC working conditions. The CHF experiments are performed in a 30 mm by 61 mm rectangular flow channel with a 200 mm long heated surface along the flow direction. Both smooth and hypervapotron surface are tested at various inclination angles of the test section to simulate various positions of the reactor lower head. The hypervapotron is found to have a 40–60% CHF improvement compared with the smooth surface. The high speed visualization indicates that hypervapotron is able to
Energy Technology Data Exchange (ETDEWEB)
Hou, Fangxin [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing (China); Chang, Huajian [Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing (China); State Nuclear Power Technology R& D Center (Beijing), Beijing (China); Zhao, Yufeng, E-mail: zhaoyufeng@snptc.com.cn [State Nuclear Power Technology R& D Center (Beijing), Beijing (China); Zhang, Ming; Gao, Tianfang [State Nuclear Power Technology R& D Center (Beijing), Beijing (China); Chen, Peipei [State Power Investment Corporation, Beijing (China)
2017-05-15
Highlights: • Natural circulation tests are performed to study the effect of hypervapotron on CHF. • Hypervapotron structure improves CHF under natural circulation conditions. • Visualization data illustrate vapor blanket behavior under subcooled flow conditions. - Abstract: The enhancement of critical heat flux with a hypervapotron structure under natural circulation conditions is investigated in this study. Subcooled flow boiling CHF experiments are performed using smooth and hypervapotron surfaces at different inclination angles under natural circulation conditions. The experimental facility, TESEC (Test of External Vessel Surface with Enhanced Cooling), is designed to conduct CHF experiments in a 30 mm by 61 mm rectangular flow channel with a 200 mm long heated surface along the flow direction. The two-phase flow of subcooled flow boiling on both smooth and hypervapotron heating plates is observed and analyzed by the high-speed visualization technology. The results show that both smooth surface and hypervapotron surface CHF data exhibit a similar trend against inclination angles compared with the CHF results under forced flow condition on the same facility in earlier studies. However, the CHF enhancement of the hypervapotron structure is evidently more significant than the one under forced flow conditions. The experiments also indicate that the natural flow rates are higher with hypervapotron structure. The initiation of CHF is analyzed under transient subcooling and flow rate conditions for both smooth and hypervapotron heating surfaces. An explanation is given for the significant enhancement effect caused by the hypervapotron surface under natural circulation conditions. The visualization data are exhibited to demonstrate the behavior of the vapor blanket at various inclination angles and on different surfaces. The geometric data of the vapor blanket are quantified by an image post-processing method. It is found that the thickness of the vapor blanket
Durand, Eric; Doutriaux, Maxime; Bettinger, Nicolas; Tron, Christophe; Fauvel, Charles; Bauer, Fabrice; Dacher, Jean-Nicolas; Bouhzam, Najime; Litzler, Pierre-Yves; Cribier, Alain; Eltchaninoff, Hélène
2017-12-11
The aim of this study was to assess the incidence, prognostic impact, and predictive factors of readmission for congestive heart failure (CHF) in patients with severe aortic stenosis treated by transcatheter aortic valve replacement (TAVR). TAVR is indicated in patients with severe symptomatic aortic stenosis in whom surgery is considered high risk or is contraindicated. Readmission for CHF after TAVR remains a challenge, and data on prognostic and predictive factors are lacking. All patients who underwent TAVR from January 2010 to December 2014 were included. Follow-up was achieved for at least 1 year and included clinical and echocardiographic data. Readmission for CHF was analyzed retrospectively. This study included 546 patients, 534 (97.8%) of whom were implanted with balloon-expandable valves preferentially via the transfemoral approach in 87.8% of cases. After 1 year, 285 patients (52.2%) had been readmitted at least once, 132 (24.1%) for CHF. Patients readmitted for CHF had an increased risk for death (p < 0.0001) and cardiac death (p < 0.0001) compared with those not readmitted for CHF. On multivariate analysis, aortic mean gradient (hazard ratio [HR]: 0.88; 95% confidence interval [CI]: 0.79 to 0.99; p = 0.03), post-procedural blood transfusion (HR: 2.27; 95% CI: 1.13 to 5.56; p = 0.009), severe post-procedural pulmonary hypertension (HR: 1.04; 95% CI: 1.00 to 1.07; p < 0.0001), and left atrial diameter (HR: 1.47; 95% CI: 1.08 to 2.01; p = 0.02) were independently associated with CHF readmission at 1 year. Readmission for CHF after TAVR was frequent and was strongly associated with 1-year mortality. Low gradient, persistent pulmonary hypertension, left atrial dilatation, and transfusions were predictive of readmission for CHF. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Critical heat flux for flow boiling of water in mini-channels
International Nuclear Information System (INIS)
Zhang, Weizhong; Mishima, Kaichiro; Hibiki, Takashi
2007-01-01
Critical heat flux (CHF) is a limiting factor when flow boiling is applied to dissipate high heat flux in mini-channels. In view of practical importance of critical heat flux correlations in engineering design and prediction, this study presents an evaluation of existing CHF correlations for flow boiling of water with available databases taken from small-diameter tubes, and then develops a new, simple CHF correlation for flow boiling in mini-channel. Three correlations by Bowring, Katto and Shah are evaluated with available CHF data in the literature for saturated flow boiling, and three correlations by Inasaka-Nariai, Celata et al. and Hall-Mudawar evaluated with the CHF data for subcooled flow boiling. The Hall-Mudawar correlation and the Shah correlation appear to be the most reliable tools for CHF prediction in the subcooled and saturated flow boiling regions, respectively. In order to avoid the defect of predictive discontinuities often encountered when applying previous correlations, a simple, nondimensional, inlet conditions dependent CHF correlation for saturated flow boiling has been formulated. Its functional form is determined by application of the artificial neural network and parametric trend analyses to the collected database. Superiority of this new correlation has been verified by the collected database. It has a mean deviation of 16.8% for this collected databank, smallest among all tested correlations. Compared to many inordinately complex correlations, this new correlation consists only of one single equation. (author)
Directory of Open Access Journals (Sweden)
Jiang-rong Zhou
2015-01-01
Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.
Standing Concertation Committee - Ordinary Meeting on 3 September 2008
HR Department
2008-01-01
The main items discussed at the meeting of the Standing Concertation Committee on 3 September 2008 included: Education fees: Indexation of the amounts for accommodation and meals The Committee approved the indexation calculations for accommodation and meals for the academic year 2008-2009. With the indexation of the lump sum payments, accommodation costs for the academic year 2007-2008 will be reimbursed at 529 CHF per month (previously CHF 500). Meals will be reimbursed at 17.50 CHF per meal (unchanged). The ceiling for school transport has been increased from 600 CHF to 622 CHF. Administrative Circular No. 26 (Rev. 8) The Committee took note of the modifications to Administrative Circular No. 26 (Rev. 8) ‘Recognition of merit of staff members’, concerning provision for the award of exceptional advancement outside the annual advancement exercise to recognize, for example, the completion of a major project. HR Survey The Committee took note of the Head of HR Department...
Critical heat-flux experiments under low-flow conditions in a vertical annulus
International Nuclear Information System (INIS)
Mishima, K.; Ishii, M.
1982-03-01
An experimental study was performed on critical heat flux (CHF) at low flow conditions for low pressure steam-water upward flow in an annulus. The test section was transparent, therefore, visual observations of dryout as well as various instrumentations were made. The data indicated that a premature CHF occurred due to flow regime transition from churn-turbulent to annular flow. It is shown that the critical heat flux observed in the experiment is essentially similar to a flooding-limited burnout and the critical heat flux can be well reproduced by a nondimensional correlation derived from the previously obtained criterion for flow regime transition. The observed CHF values are much smaller than the standard high quality CHF criteria at low flow, corresponding to the annular flow film dryout. This result is very significant, because the coolability of a heater surface at low flow rates can be drastically reduced by the occurrence of this mode of CHF
Voss, Andreas; Schroeder, Rico; Caminal Magrans, Pere; Vallverdú Ferrer, Montserrat; Brunel, Helena; Cygankiewicz, I.; Vázquez, Rafael; Bayes de Luna, Antonio
2010-01-01
Chronic heart failure (CHF) is recognized as major and escalating public health problem. Approximately 69% of CHF patients suffer from cardiac death within 5 years after the initial diagnosis. Until now, no generally accepted ECG risk predictors in CHF patients are available. The objective of this study was to investigate the suitability of the new developed non-linear method segmented symbolic dynamics (SSD) for risk stratification in patients with ischemic cardiomyop...
Jaffuel, Dany; Molinari, Nicolas; Berdague, Philippe; Pathak, Atul; Galinier, Michel; Dupuis, Marion; Ricci, Jean-Etienne; Mallet, Jean-Pierre; Bourdin, Arnaud; Roubille, François
2018-06-01
Sleep-disordered breathing (SDB) is a highly prevalent co-morbidity in patients with chronic heart failure (CHF) and can play a detrimental role in the pathophysiology course of CHF. However, the best way to manage SDB in CHF remains a matter of debate. Sacubitril-valsartan has been included in the 2016 European Society of Cardiology guidelines as an alternative to angiotensin-converting enzyme inhibitors to further reduce the risk of progression of CHF, CHF hospitalization, and death in ambulatory patients. Sacubitril and valsartan are good candidates for correcting SDB of CHF patients because their known mechanisms of action are likely to counteract the pathophysiology of SDB in CHF. The ENTRESTO-SAS trial is a 3-month, multicentric, prospective, open-label real-life cohort study. Patients eligible for sacubitril-valsartan treatment (i.e. adults with left ventricular ejection fraction ≤35%, who remain symptomatic despite optimal treatment with an angiotensin-converting enzyme inhibitor, a beta-blocker, and a mineralocorticoid receptor antagonist) will be evaluated before and after 3 months of treatment (nocturnal ventilatory polygraphy, echocardiography, laboratory testing, and quality-of-life and SDB questionnaires). The primary outcome is the change in the Apnoea-Hypopnoea Index, before and after 3 months of treatment. One hundred twenty patients are required to detect a significant 20% improvement of the Apnoea-Hypopnoea Index with a power of 90% at an alpha risk of 5%. In the context of the SERVE-HF study, physicians are waiting for new trials and alternative therapies. We sought to assess in the ENTRESTO-SAS trial whether sacubitril-valsartan could improve the outcome of SDB in CHF patients. © 2018 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.
Compromised Global and Regional Cerebral Blood Flow in Congestive Heart Failure
Energy Technology Data Exchange (ETDEWEB)
Kim, J. S.; Kim, J. J.; Im, K. C.; Moon, D. H. [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of)
2003-07-01
It has been known that cerebral perfusion is maintained in patients with congestive heart failure (CHF) by a complex series of compensatory mechanisms. However cognitive impairment is a common problem experienced by patients with CHF and may result from deranged cerebral perfusion. We prospectively investigated the global and regional CBF of patients with CHF and compared the results with that of normal controls. Thirty two patients (M/F: 22/10, 4211 yr) with CHF (LVEF=218.1%) and 10 healthy controls (M/F: 6/4, 398 yr) were prospectively studied. No patients had cerebrovascular disease or other disease affecting cognitive function. All patients and normal controls underwent radionuclide angiography including cerebral hemispheres and aortic arch, and brain perfusion SPECT using Tc-99m ECD. Global CBF was measured non-invasively by the application of Patlak plot graphical analysis. Quantitative rCBF images were obtained from SPECT image using global CBF values, regional/global count ratios, and Lassen's linearization correction algorithm. Difference of regional CBF between CHF and normal control were assessed using a SPM99 without global count normalization (uncorrected p<0.0001, extent threshold>100 voxels). Global CBF (41.54.7 ml/min/100g) of the patients with CHF were significantly lower than those (49.15.7 ml/min/100g) of controls (p<0.001). Regional CBF was significantly decreased in frontal, temporal and parietal neocortex of both cerebral hemispheres compared to normal controls. Regional rCBF of basal ganglia, thalamus, and brain stem were preserved, even though global CBF was variably compromised. Our study show that global CBF is significantly decreased in CHF and regional CBF of frontal, parietal and temporal neocortex is compromised preferentially. Further studies would be needed to investigate the relationship of rCBF change and cognitive impairment in patients with CHF.
Energy Technology Data Exchange (ETDEWEB)
Brown, Nicholas R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wysocki, Aaron J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Terrani, Kurt A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ali, Amir [Univ. of New Mexico, Albuquerque, NM (United States); Liu, Maolong [Univ. of New Mexico, Albuquerque, NM (United States); Blandford, Edward [Univ. of New Mexico, Albuquerque, NM (United States)
2016-06-01
The U.S. Department of Energy Office of Nuclear Energy (DOE-NE) Advanced Fuels Campaign (AFC) is working closely with the nuclear industry to develop fuel and cladding candidates with potentially enhanced accident tolerance, also known as accident tolerant fuel (ATF). Thermal-fluids characteristics are a vital element of a holistic engineering evaluation of ATF concepts. One vital characteristic related to boiling heat transfer is the critical heat flux (CHF). CHF plays a vital role in determining safety margins during normal operation and also in the progression of potential transient or accident scenarios. This deliverable is a scoping survey of thermal-fluids evaluation and confirmatory experimental validation requirements of accident tolerant cladding concepts with a focus on boiling heat transfer characteristics. The key takeaway messages of this report are: 1. CHF prediction accuracy is important and the correlations may have significant uncertainty. 2. Surface conditions are important factors for CHF, primarily the wettability that is characterized by contact angle. Smaller contact angle indicates greater wettability, which increases the CHF. Surface roughness also impacts wettability. Results in the literature for pool boiling experiments indicate changes in CHF by up to 60% for several ATF cladding candidates. 3. The measured wettability of FeCrAl (i.e., contact angle and roughness) indicates that CHF should be investigated further through pool boiling and flow boiling experiments. 4. Initial measurements of static advancing contact angle and surface roughness indicate that FeCrAl is expected to have a higher CHF than Zircaloy. The measured contact angle of different FeCrAl alloy samples depends on oxide layer thickness and composition. The static advancing contact angle tends to decrease as the oxide layer thickness increases.
International Nuclear Information System (INIS)
Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuogl u, B.
2007-01-01
Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF
Energy Technology Data Exchange (ETDEWEB)
Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuoglu, B. (Radiology Dept. and Cardiology Dept., Kocaeli Univ. School of Medicine, Kocaeli (Turkey))
2007-11-15
Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P = 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF
Influence of heart failure on resting lung volumes in patients with COPD
de Souza, Aline Soares; Sperandio, Priscila Abreu; Mazzuco, Adriana; Alencar, Maria Clara; Arbex, Flávio Ferlin; de Oliveira, Mayron Faria; O'Donnell, Denis Eunan; Neder, José Alberto
2016-01-01
ABSTRACT Objective: To evaluate the influence of chronic heart failure (CHF) on resting lung volumes in patients with COPD, i.e., inspiratory fraction-inspiratory capacity (IC)/TLC-and relative inspiratory reserve-[1 − (end-inspiratory lung volume/TLC)]. Methods: This was a prospective study involving 56 patients with COPD-24 (23 males/1 female) with COPD+CHF and 32 (28 males/4 females) with COPD only-who, after careful clinical stabilization, underwent spirometry (with forced and slow maneuvers) and whole-body plethysmography. Results: Although FEV1, as well as the FEV1/FVC and FEV1/slow vital capacity ratios, were higher in the COPD+CHF group than in the COPD group, all major "static" volumes-RV, functional residual capacity (FRC), and TLC-were lower in the former group (p < 0.05). There was a greater reduction in FRC than in RV, resulting in the expiratory reserve volume being lower in the COPD+CHF group than in the COPD group. There were relatively proportional reductions in FRC and TLC in the two groups; therefore, IC was also comparable. Consequently, the inspiratory fraction was higher in the COPD+CHF group than in the COPD group (0.42 ± 0.10 vs. 0.36 ± 0.10; p < 0.05). Although the tidal volume/IC ratio was higher in the COPD+CHF group, the relative inspiratory reserve was remarkably similar between the two groups (0.35 ± 0.09 vs. 0.44 ± 0.14; p < 0.05). Conclusions: Despite the restrictive effects of CHF, patients with COPD+CHF have relatively higher inspiratory limits (a greater inspiratory fraction). However, those patients use only a part of those limits, probably in order to avoid critical reductions in inspiratory reserve and increases in elastic recoil. PMID:27832235
Multidisciplinary management of chronic heart failure: principles and future trends.
Davidson, Patricia M; Newton, Phillip J; Tankumpuan, Thitipong; Paull, G; Dennison-Himmelfarb, Cheryl
2015-10-01
Globally, the management of chronic heart failure (CHF) challenges health systems. The high burden of disease and the costs associated with hospitalization adversely affect individuals, families, and society. Improved quality, access, efficiency, and equity of CHF care can be achieved by using multidisciplinary care approaches if there is adherence and fidelity to the program's elements. The goal of this article was to summarize evidence and make recommendations for advancing practice, education, research, and policy in the multidisciplinary management of patients with CHF. Essential elements of multidisciplinary management of CHF were identified from meta-analyses and clinical practice guidelines. The study factors were discussed from the perspective of the health care system, providers, patients, and their caregivers. Identified gaps in evidence were used to identify areas for future focus in CHF multidisciplinary management. Although there is high-level evidence (including several meta-analyses) for the efficacy of management programs for CHF, less evidence exists to determine the benefit attributable to individual program components or to identify the specific content of effective components and the manner of their delivery. Health care system, provider, and patient factors influence health care models and the effective management of CHF and require focus and attention. Extrapolating trial findings to clinical practice settings is limited by the heterogeneity of study populations and the implementation of models of intervention beyond academic health centers, where practice environments differ considerably. Ensuring that individual programs are both developed and assessed that consider these factors is integral to ensuring adherence and fidelity with the core dimensions of disease management necessary to optimize patient and organizational outcomes. Recognizing the complexity of the multidisciplinary CHF interventions will be important in advancing the design
Flooding correlations in narrow channel
International Nuclear Information System (INIS)
Kim, S. H.; Baek, W. P.; Chang, S. H.
1999-01-01
Heat transfer in narrow gap is considered as important phenomena in severe accidents in nuclear power plants. Also in heat removal of electric chip. Critical heat flux(CHF) in narrow gap limits the maximum heat transfer rate in narrow channel. In case of closed bottom channel, flooding limited CHF occurrence is observed. Flooding correlations will be helpful to predict the CHF in closed bottom channel. In present study, flooding data for narrow channel geometry were collected and the work to recognize the effect of the span, w and gap size, s were performed. And new flooding correlations were suggested for high-aspect-ratio geometry. Also, flooding correlation was applied to flooding limited CHF data
Association du personnel
2010-01-01
THEATRE FORUM DE MEYRIN 1, place des Cinq-Continents 1217 Meyrin Special offer for members of the Staff Association: Reduced ticket prices for the play Love is my sin (in English) from 15 to 17 March at 8.30pm http://www.forum-meyrin.ch/main.php?page=119&s=12 First category: 37 CHF instead of 46 CHF Second category (seats towards the sides): 30 CHF instead of 38 CHF Please present your CERN card and your Staff Association membership card at the ticket office. Ticket reservation: tel. 022 989 34 34 (from Monday to Friday 2pm to 6pm) or e-mail : billetterie@forum-meyrin.ch
Prediction of critical heat flux in vertical pipe flow
International Nuclear Information System (INIS)
Levy, S.; Healzer, J.M.; Abdollahian, D.
1981-01-01
A previously developed semi-empirical model for adiabatic two-phase annular flow ix extended to predict the critical heat flux (CHF) in a vertical pipe. The model exhibits a sharply declining curve of CHF versus steam quality (X) at low X, and is relatively independent of the heat flux distribution. In this region, vaporization of the liquid film controls. At high X, net deposition upon the liquid film becomes important and CHF versus X flattens considerably. In this zone, CHF is dependent upon the heat flux distribution. Model predictions are compared to test data and an empirical correlation. The agreement is generally good if one employs previously reported mass transfer coefficients. (orig.)
Biotransformation of Stypotriol triacetate by Aspergillus niger
Areche, Carlos; Vaca, Inmaculada; Labbe, Pamela; Soto-Delgado, Jorge; Astudillo, Luis; Silva, Mario; Rovirosa, Juana; San-Martin, Aurelio
2011-07-01
Biological transformation of the meroditerpenoid, stypotriol triacetate ( 1) by the fungi Aspergillus niger, Cunninghamella elegans, Gibberella fujikuroi and Mucor plumbeus was studied. The incubation of 1 with A. niger yielded the new compound 6',14-diacetoxy-stypol-4,5-dione ( 2) whose structure was established by 1H, 13C and 2D NMR and supported by DFT/GIAO.
He-3 NMR: from free gas to its encapsulation in fullerene
Czech Academy of Sciences Publication Activity Database
Kupka, T.; Stachów, M.; Stobinski, L.; Kaminský, Jakub
2013-01-01
Roč. 51, č. 8 (2013), s. 463-468 ISSN 0749-1581 R&D Projects: GA ČR GAP208/11/0105 Grant - others:AV ČR(CZ) M200551205 Institutional support: RVO:61388963 Keywords : He-3 NMR * GIAO * molecular modeling * ab initio * fullerene * SWCNT Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.559, year: 2013
An Investigation of Emotion Recognition and Theory of Mind in People with Chronic Heart Failure
Habota, Tina; McLennan, Skye N.; Cameron, Jan; Ski, Chantal F.; Thompson, David R.; Rendell, Peter G.
2015-01-01
Objectives Cognitive deficits are common in patients with chronic heart failure (CHF), but no study has investigated whether these deficits extend to social cognition. The present study provided the first empirical assessment of emotion recognition and theory of mind (ToM) in patients with CHF. In addition, it assessed whether each of these social cognitive constructs was associated with more general cognitive impairment. Methods A group comparison design was used, with 31 CHF patients compared to 38 demographically matched controls. The Ekman Faces test was used to assess emotion recognition, and the Mind in the Eyes test to measure ToM. Measures assessing global cognition, executive functions, and verbal memory were also administered. Results There were no differences between groups on emotion recognition or ToM. The CHF group’s performance was poorer on some executive measures, but memory was relatively preserved. In the CHF group, both emotion recognition performance and ToM ability correlated moderately with global cognition (r = .38, p = .034; r = .49, p = .005, respectively), but not with executive function or verbal memory. Conclusion CHF patients with lower cognitive ability were more likely to have difficulty recognizing emotions and inferring the mental states of others. Clinical implications of these findings are discussed. PMID:26529409
Review of the critical heat flux correlations for liquid metals
International Nuclear Information System (INIS)
Lee, Yong Bum; Han, H. D.; Chang, W. P.; Kwon, Y. M.
1999-09-01
The CHF phenomenon in the two-phase convective flows has been an important issue in the fields of design and safety analysis of light water reactor (LWR) as well as sodium cooled liquid metal reactor (LMR). Especially in the LWR application, many physical aspects of the CHF phenomenon are understood and reliable correlations and mechanistic models to predict the CHF condition have been proposed over the past three decades. Most of the existing CHF correlations have been developed for light water reactor core applications. Compared with water, liquid metals show a divergent picture of boiling pattern. This can be attributed to the consequence that special CHF conditions obtained from investigations with water cannot be applied to liquid metals. Numerous liquid metal boiling heat transfer and two-phase flow studies have put emphasis on development of models and understanding of the mechanism for improving the CHF predictions. Thus far, no overall analytical solution method has been obtained and the reliable prediction method has remained empirical. The principal objectives of the present report are to review the state of the art in connection with liquid metal critical heat flux under low pressure and low flow conditions and to discuss the basic mechanisms. (author)
Flow induced vibration characteristics in 2X3 bundle critical heat flux experiment
International Nuclear Information System (INIS)
Kim, Dae Hun; Chang, Soon Heung
2005-01-01
Above a certain heat flux, the liquid can no longer permanently wet the heater surface. This situation leads to an inordinate decrease in the surface heat transfer. This heat flux is commonly referred to as the critical heat flux (CHF). The CHF in nuclear reactors is one of the important thermal hydraulic parameters limiting the available power. Flow induced vibration (FIV) is the vibration caused by a fluid flowing around a body. In the fluid flowing system, FIV occurred by structures and flow condition. Many structures in nuclear power plant system are designed to prevent from structure failure due to FIV. Recently, Hibiki and Ishii (1998) carried out an experimental investigation on the effect of flow-induced vibration (FIV) on two-phase flow structure in vertical tube and reported that the FIV drastically changed the void fraction profiles. The void fraction profiles is one of the important parameter for determining CHF. Therefore, the investigation on the effect of FIV on CHF are needed. The research on FIV characteristics detection during CHF experiment in 2X3 bundle using R-134a has been carried out in KAIST. Using the results new FIV correlation in 2-pahse turbulent flow are suggested after finding out relation between CHF and dynamic pressure fluctuation value
Dschietzig, Thomas B; Boschann, Felix; Ruppert, Jana; Armbruster, Franz P; Meinitzer, Andreas; Bankovic, Dragic; Mitrovic, Veselin; Melzer, Christoph
2016-12-01
The tight junction regulator zonulin has attracted clinical attention as a biomarker of increased gastrointestinal permeability. Recent work also suggests zonulin to represent a general regulator of tissue barriers and a player in metabolic inflammation. Here, we investigated the associations of zonulin with chronic heart failure (CHF), kidney function, and metabolic inflammation. Using multiple linear regression (Generalized Linear Model), this study determined the association of plasma zonulin with different laboratory and clinical parameters in 225 patients carrying automatic implantable cardioverters/defibrillators (AICD) for primary or secondary prevention. In another 115 patients with diastolic or systolic CHF, we investigated a possible relationship between zonulin and CHF severity. In the AICD cohort, zonulin associated inversely with serum creatinine (p = 0.013), carboxymethyl-lysine calprotectin (p zonulin increased significantly with high-sensitivity CRP (p = 0.014). In the CHF cohort, we found a highly significant rise of NT-proBNP, but not of zonulin with NYHA functional classes I-IV or other parameters of CHF severity. The inverse associations of zonulin with creatinine and markers of cardio-vascular risk (high CMLcalprotectin and kynurenine, low homoarginine) are novel findings that need further experimental and clinical clarification. Our study indicates zonulin involvement in metabolic inflammation in T2D, but no association with disease status in CHF.
Critical heat flux tests for a 12 finned-element assembly
Energy Technology Data Exchange (ETDEWEB)
Yang, J., E-mail: Jun.Yang@cnl.ca; Groeneveld, D.C.; Yuan, L.Q.
2017-03-15
Highlights: • CHF tests for a 12 finned-fuel-element assembly at highly subcooled conditions. • Test approach to maximize experimental information and minimize heater failures. • Three series of tests were completed in vertical upward light water flow. • Bundle simulators of two axial power profiles and three heated lengths were tested. • Results confirm that the prediction method predicts lower CHF values than measured. - Abstract: An experimental study was undertaken to provide relevant data to validate the current critical heat flux (CHF) prediction method of the NRU driver fuel for safety analysis, i.e., to confirm no CHF occurrence below the predicted values. The NRU driver fuel assembly consists of twelve finned fuel elements arranged in two rings – three in the inner ring and nine in the outer ring. To satisfy the experimental objective tests at very high heat fluxes, very high mass velocities, and high subcoolings were conducted where the CHF mechanism is the departure from nucleate boiling (DNB). Such a CHF experiment can be very difficult, costly and time consuming since failure of the heating surface due to rupture or melting (physical burnout) is expected when the DNB type of CHF is reached. A novel experimental approach has been developed to maximize the amount of relevant experimental information on safe operating conditions in the tests, and to minimize any possible heater failures that inherently accompany the CHF occurrence at these conditions. Three series of tests using electrically heated NRU driver fuel simulators with three heated lengths and two axial power profiles (or axial heat flux distribution (AFD)) were completed in vertical upward light water flow. Each series of tests covered two mass flow rates, several heat flux levels, and local subcoolings that bound the ranges of interest for the analysis of postulated slow loss-of-regulation accident (LORA) and loss-of-flow accident (LOFA) scenarios. Tests for each mass flow rate of
DEFF Research Database (Denmark)
Falk, Bo Torkel; Jönsson, Lennart; Olsen, Lisbeth Høier
2010-01-01
The objective of this study was to correlate defined pathological features with clinical findings in dogs with naturally occurring congestive heart failure (CHF). Fifty-eight dogs with CHF were examined clinically and using echocardiography and electrocardiography. Detailed cardiac post...... such as MMVD, myocardial atrophy and fibrosis, and by arteriosclerosis. Further, more extensive research will be required to establish cause-effect relationships between these cardiac lesions and the pathophysiology of CHF in dogs....
Staff Association
2017-01-01
Summer is here, enjoy our offers for the aquatic parcs! Walibi : Tickets "Zone terrestre": 24 € instead of 30 €. Access to Aqualibi: 5 € instead of 6 € on presentation of your SA member ticket. Free for children under 100 cm. Car park free. * * * * * Aquaparc : Day ticket: – Children: 33 CHF instead of 39 CHF – Adults : 33 CHF instead of 49 CHF Bonus! Free for children under 5.
Staff Association
2017-01-01
Summer is coming, enjoy our offers for the aquatic parcs! Walibi : Tickets "Zone terrestre": 24 € instead of 30 €. Access to Aqualibi: 5 € instead of 6 € on presentation of your SA member ticket. Free for children under 100 cm. Car park free. * * * * * Aquaparc : Day ticket: – Children: 33 CHF instead of 39 CHF – Adults : 33 CHF instead of 49 CHF Bonus! Free for children under 5.
Ha, Minseok; Graham, Samuel
2017-08-01
Experimental studies have shown that microporous surfaces induce one of the highest enhancements in critical heat flux (CHF) during pool boiling. However, microporous surfaces may also induce a very large surface superheat (>100 °C) which is not desirable for applications such as microelectronics cooling. While the understanding of the CHF mechanism is the key to enhancing boiling heat transfer, a comprehensive understanding is not yet available. So far, three different theories for the CHF of microporous surfaces have been suggested: viscous-capillary model, hydrodynamic instability model, and dryout of the porous coatings. In general, all three theories account for some aspects of boiling phenomena. In this study, the theories are examined through their correlations with experimental data on microporous surfaces during pool boiling using deionized (DI) water. It was found that the modulation of the vapor-jet through the pore network enables a higher CHF than that of a flat surface based on the hydrodynamic instability theory. In addition, it was found that as the heat flux increases, a vapor layer grows in the porous coatings described by a simple thermal resistance model which is responsible for the large surface superheat. Once the vapor layer grows to fill the microporous structure, transition to film boiling occurs and CHF is reached. By disrupting the formation of this vapor layer through the fabrication of channels to allow vapor escape, an enhancement in the CHF and heat transfer coefficient was observed, allowing CHF greater than 3500 kW/m2 at a superheat less than 50 °C.
Yokota, Junichi; Ogawa, Yoshiko; Yamanaka, Shinsuke; Takahashi, Yoshimi; Fujita, Hiroshi; Yamaguchi, Nobuhiro; Onoue, Noriko; Ishizuka, Takeshi; Shinozaki, Tsuyoshi; Kohzuki, Masahiro
2016-01-01
Early detection and intervention for dysphagia is important in patients with congestive heart failure (CHF). However, previous studies have focused on how many patients with dysphagia develop CHF. Studies focusing on the comorbidity of dysphagia in patients with CHF are rare. Additionally, risk factors for dysphagia in patients with CHF are unclear. Thus, the aim of this study was to clarify risk factors for dysphagia in patients with acute exacerbation of CHF. A total of 105 patients, who were admitted with acute exacerbation of CHF, were enrolled. Clinical interviews, blood chemistry analysis, electrocardiography, echocardiography, Mini-Mental State Examination (MMSE), exercise tolerance tests, phonatory function tests, and evaluation of activities of daily living (ADL) and nutrition were conducted on admission. After attending physicians permitted the drinking of water, swallowing screening tests were performed. Patients were divided into a dysphagia group (DG) or a non-dysphagia group (non-DG) based on Functional Oral Intake Scale level. Among the 105 patients, 38 had dysphagia. A greater number of patients had history of aspiration pneumonia and dementia, and there was a higher age, N-terminal pro-B-type natriuretic peptide level in the DG compared with the non-DG. MMSE scores, exercise tolerance, phonatory function, status of ADL, nutrition, albumin, and transthyretin were lower in the DG compared with the non-DG. In multivariate analysis, after adjusting for age and sex, MMSE, BI score, and transthyretin was independently associated with dysphagia. Comorbidity of dysphagia was 36.1% in patients with acute exacerbation of CHF, and cognitive dysfunction and malnutrition may be an independent predictor of dysphagia.
Directory of Open Access Journals (Sweden)
Tam H Ho
Full Text Available OBJECTIVE: To assess the impact of individualised, reconciled evidence-based recommendations (IRERs and multidisciplinary care in patients with chronic heart failure (CHF on clinical guideline compliance for CHF and common comorbid conditions. DESIGN AND SETTING: A retrospective hospital clinical audit conducted between 1st July 2006 and February 2011. PARTICIPANTS: A total of 255 patients with a diagnosis of CHF who attended the Multidisciplinary Ambulatory Consulting Services (MACS clinics, at the Royal Adelaide Hospital, were included. MAIN OUTCOME MEASURES: Compliance with Australian clinical guideline recommendations for CHF, atrial fibrillation, diabetes mellitus and ischaemic heart disease. RESULTS: Study participants had a median of eight medical conditions (IQR 6-10 and were on an average of 10 (±4 unique medications. Compliance with clinical guideline recommendations for pharmacological therapy for CHF, comorbid atrial fibrillation, diabetes or ischaemic heart disease was high, ranging from 86% for lipid lowering therapy to 98% anti-platelet agents. For all conditions, compliance with lifestyle recommendations was lower than pharmacological therapy, ranging from no podiatry reviews for CHF patients with comorbid diabetes to 75% for heart failure education. Concordance with many guideline recommendations was significantly associated if the patient had IRERs determined, a greater number of recommendations, more clinic visits or if patients participated in a heart failure program. CONCLUSIONS: Despite the high number of comorbid conditions and resulting complexity of the management, high compliance to clinical guideline recommendations was associated with IRER determination in older patients with CHF. Importantly these recommendations need to be communicated to the patient's general practitioner, regularly monitored and adjusted at clinic visits.
Adlbrecht, Christopher; Hülsmann, Martin; Strunk, Guido; Berger, Rudolf; Mörtl, Deddo; Struck, Joachim; Morgenthaler, Nils G; Bergmann, Andreas; Jakowitsch, Johannes; Maurer, Gerald; Lang, Irene M; Pacher, Richard
2009-04-01
The identification of chronic heart failure (CHF) patients at high risk of adverse outcome remains a challenge. New peptides are emerging that may give additional information. In CHF patients, endothelin (ET) levels predict mortality risk. Adrenomedullin has been shown to predict mortality in ischaemic heart failure, but not in unselected or non-ischaemic CHF patients. Moreover, ADM and ET have never been assessed in one model. The aim of the present study was to assess the prognostic value of midregional-pro-adrenomedullin (MR-proADM) and C-terminal-pro-endothelin-1 (CT-proET-1) in outpatients with CHF. We measured plasma MR-proADM and CT-proET-1 levels in 786 consecutive CHF outpatients and compared them with B-type natriuretic peptide (BNP) levels. At 24-month follow-up, 233 patients had died. A stepwise forward Cox regression model with age, sex, estimated glomerular filtration rate, NYHA > II, left ventricular ejection fraction (LVEF), MR-proADM, CT-proET-1, and BNP as possible predictors revealed that MR-proADM levels [hazard ratio (HR) = 1.77, P II (HR = 1.86, P < 0.001) were predictors of death at 24 months. When the analysis was repeated dependent on NYHA-stage, MR-proADM (HR = 2.12, P < 0.001) and LVEF (HR = 0.96, P = 0.006) were significant markers, but only in patients with mild/moderate CHF. Our data suggest that MR-proADM may be an important prognostic humoral marker, especially in mild/moderately symptomatic and non-ischaemic CHF patients.
International Nuclear Information System (INIS)
Fong, R.W.L.; Nitheanandan, T.; Bullock, C.D.; Slater, L.F.; McRae, G.A.
2003-05-01
Glass-bead peening the outside surfaces of zirconium alloy tubes has been shown to increase the Critical Heat Flux (CHF) in pool boiling of water. The CHF is found to correlate with the fractal roughness of the metal tube surfaces. In this study on the effect of oxidation on glass-peened surfaces, test measurements for CHF, surface wettability and roughness have been evaluated using various glass-peened and oxidized zirconium alloy tubes. The results show that oxidation changes the solid-liquid contact angle (i.e., decreases wettability of the metal-oxide surface), but does not change the fractal surface roughness, appreciably. Thus, oxidation of the glass-peened surfaces of zirconium alloy tubes is not expected to degrade the CHF enhancement obtained by glass-bead peening. (author)
The Indian Consensus Document on cardiac biomarker
Directory of Open Access Journals (Sweden)
I. Satyamurthy
2014-01-01
Full Text Available Despite recent advances, the diagnosis and management of heart failure evades the clinicians. The etiology of congestive heart failure (CHF in the Indian scenario comprises of coronary artery disease, diabetes mellitus and hypertension. With better insights into the pathophysiology of CHF, biomarkers have evolved rapidly and received diagnostic and prognostic value. In CHF biomarkers prove as measures of the extent of pathophysiological derangement; examples include biomarkers of myocyte necrosis, myocardial remodeling, neurohormonal activation, etc. In CHF biomarkers act as indicators for the presence, degree of severity and prognosis of the disease, they may be employed in combination with the present conventional clinical assessments. These make the biomarkers feasible options against the present expensive measurements and may provide clinical benefits.
International Nuclear Information System (INIS)
Hejzlar, P.; Todreas, N.E.
1996-01-01
The accurate prediction of the critical heat flux (CHF) margin which is a key design parameter in a variety of cooling and heating systems is of high importance. These margins are, for the low quality region, typically expressed in terms of critical heat flux ratios using the direct substitution method. Using a simple example of a heated tube, it is shown that CHF correlations of a certain type often used to predict CHF margins, expressed in this manner, may yield different results, strongly dependent on the correlation in use. It is argued that the application of the heat balance method to such correlations, which leads to expressing the CHF margins in terms of the critical power ratio, may be more appropriate. (orig.)
Consensus statement on management of chronic heart failure in India
Directory of Open Access Journals (Sweden)
Sandeep Seth
2015-01-01
Full Text Available Summary of the Consensus Statement: This statement has been prepared keeping Indian heart failure patients in mind. Optimal management of CHF improves quality of life, reduces hospitalization rates and prolongs survival for people with this condition. Echocardiography is the single most useful test in the evaluation of heart failure, and is necessary to confirm the diagnosis. Plasma B-natriuretic peptide (BNP measurements may be useful in excluding CHF but not mandatory in India. Educate people with CHF about lifestyle changes (e.g., increase physical activity levels, reduce salt intake and manage weight. Educate people with CHF about CHF symptoms and how to manage fluid load. Avoid prescribing drugs that exacerbate CHF. Prescribe angiotensin-converting enzyme inhibitors (ACEI at effective doses for people with all grades of systolic heart failure, and titrate to the highest recommended dose tolerated. Angiotensin II receptor antagonists (ARA may be used as alternatives in people who cannot tolerate ACEIs. Mineralocorticoid receptor antagonists (MRAs should also be used. For people with stabilised systolic heart failure, prescribe beta-blockers that have been shown to improve outcome in heart failure (e.g., bisoprolol, carvedilol, extended release metoprolol or nebivolol. Titrate to the highest recommended dose tolerated. Prescribe diuretics, digoxin and nitrates for people already using ACEIs and beta-blockers to manage symptoms as indicated. For people who have systolic heart failure (New York Heart Association (NYHA Class II-IV despite appropriate doses of ACEIs and diuretics, consider prescribing spironolactone. Eplerenone can be considered in certain setting especially post myocardial infarction though it is more expensive. Consider direct sinus node inhibition with ivabradine for people with CHF who have impaired systolic function, have had a recent heart failure hospitalisation and are in sinus rhythm with a heart rate >70 bpm despite
Staff Association
2018-01-01
Summer is coming, enjoy our offers for the aquatic parcs! Walibi : Tickets "Zone terrestre": 25 € instead of 31 €. Access to Aqualibi: 5 € instead of 8 € on presentation of your Staff Association member ticket. Free for children under 100 cm. Car park free. * * * * * Aquaparc : Day ticket: – Children: 33 CHF instead of 39 CHF – Adults : 33 CHF instead of 49 CHF Bonus! Free for children under 5.
Gunay-Aygun, Meral; Avner, Ellis D.; Bacallo, Robert L.; Choyke, Peter L.; Flynn, Joseph T.; Germino, Gregory G.; Guay-Woodford, Lisa; Harris, Peter; Heller, Theo; Ingelfinger, Julie; Kaskel, Frederick; Kleta, Robert; LaRusso, Nicholas F.; Mohan, Parvathi; Pazour, Gregory J.; Shneider, Benjamin L.; Torres, Vicente E.; Wilson, Patricia; Zak, Colleen; Zhou, Jing; Gahl, William A.
2010-01-01
Researchers and clinicians with expertise in autosomal recessive polycystic kidney disease and congenital hepatic fibrosis (ARPKD/CHF) and related fields met on May 5-6, 2005, on the National Institutes of Health (NIH) campus for a 1.5-day symposium sponsored by the NIH Office of Rare Diseases, the National Human Genome Research Institute (NHGRI), and in part by the ARPKD/CHF Alliance. The meeting addressed the present status and the future of ARPKD/CHF research. PMID:16887426
Fitness Club
2015-01-01
Four classes of one hour each are held on Tuesdays. RDV barracks parking at Entrance A, 10 minutes before class time. Spring Course 2015: 05.05/12.05/19.05/26.05 Prices 40 CHF per session + 10 CHF club membership 5 CHF/hour pole rental Check out our schedule and enroll at: https://espace.cern.ch/club-fitness/Lists/Nordic%20Walking/NewForm.aspx? Hope to see you among us! fitness.club@cern.ch
International Nuclear Information System (INIS)
Carver, M.B.; Kiteley, J.C.; Zhou, R.Q.N.; Junop, S.V.; Rowe, D.S.
1995-01-01
The ASSERT code has been developed to address the three-dimensional computation of flow and phase distribution and fuel element surface temperatures within the horizontal subchannels of Canada uranium deuterium (CANDU) pressurized heavy water reactor fuel channels and to provide a detailed prediction of critical heat flux (CHF) distribution throughout the bundle. The ASSERT subchannel code has been validated extensively against a wide repertoire of experiments; its combination of three-dimensional prediction of local flow conditions with a comprehensive method of predicting CHF at these local conditions makes it a unique tool for predicting CHF for situations outside the existing experimental database. In particular, ASSERT is an appropriate tool to systematically investigate CHF under conditions of local geometric variations, such as pressure tube creep and fuel element strain. The numerical methodology used in ASSERT, the constitutive relationships incorporated, and the CHF assessment methodology are discussed. The evolutionary validation plan is also discussed and early validation exercises are summarized. More recent validation exercises in standard and nonstandard geometries are emphasized
Liu, Hao; Shi, Hong; Yu, Jinming; Chen, Fang; Jiang, Qingwu; Hu, Dayi
2011-08-01
Obesity and decreased kidney function have been shown to be prevalent in Western patients with heart failure; however, whether this phenomenon exists in Chinese patients with chronic heart failure (CHF) is not known. One thousand and nine patients with CHF from the China Heart Survey were assessed. The prevalence of chronic kidney disease (CKD) was 34.2%, and there was a stepwise increase in the prevalence of CKD with New York Heart Association (NYHA) classes (P obesity and central obesity was 35.7% and 62.5%, respectively. Notably, there was a downward trend in the prevalence of obesity with advanced NYHA classes (trend test, P = 0.003). Multivariate analysis further supported the finding that obesity, but not central obesity, was inversely associated with the extent of CHF (OR = 0.72, 95% CI: 0.55-0.94, P = 0.017). Renal dysfunction is common in Chinese patients with CHF and is independently associated with advanced NYHA classes. Obesity was inversely associated with the extent of CHF, which further supports the notion that obesity confers improved prognosis in patients with heart failure.
International Nuclear Information System (INIS)
Nickerson, J.R.
1982-05-01
A 6-m, 37-element, electrically heated bundle with full end plate simulation, cooled by Freon-12, has been tested for CHF (critical heat flux) and post-CHF conditions in the MR-3 Freon loop. The bundle was tested in a horizontal attitude and had a uniform axial heat flux distribution and radial heat flux depression. A total of 110 CHF points have been collected over the following range of water equivalent conditions: exit pressure 8.27 - 11.03 MPa, mass flux 1.38 - 8.14 Mg.m -2 .s -1 , inlet subcooling 0 - 500 kJ.kg -1 , outlet quality 10% - 37%. The data have been correlated on both a systems and local conditions basis over a limited mass flux range to within 2.8% rms. Significant CHF increases over smooth bundle results have been observed along with significant CHF improvement over a two end plate bundle simulation in the lower mass flux ranges. A satisfactory axial drypatch spreading correlation has been determined and extensive drypatch wall superheat mapping has been performed
Prediction of critical heat flux using ANFIS
Energy Technology Data Exchange (ETDEWEB)
Zaferanlouei, Salman, E-mail: zaferanlouei@gmail.co [Nuclear Engineering and Physics Department, Faculty of Nuclear Engineering, Center of Excellence in Nuclear Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of); Rostamifard, Dariush; Setayeshi, Saeed [Nuclear Engineering and Physics Department, Faculty of Nuclear Engineering, Center of Excellence in Nuclear Engineering, Amirkabir University of Technology (Tehran Polytechnic), 424 Hafez Avenue, Tehran (Iran, Islamic Republic of)
2010-06-15
The prediction of Critical Heat Flux (CHF) is essential for water cooled nuclear reactors since it is an important parameter for the economic efficiency and safety of nuclear power plants. Therefore, in this study using Adaptive Neuro-Fuzzy Inference System (ANFIS), a new flexible tool is developed to predict CHF. The process of training and testing in this model is done by using a set of available published field data. The CHF values predicted by the ANFIS model are acceptable compared with the other prediction methods. We improve the ANN model that is proposed by to avoid overfitting. The obtained new ANN test errors are compared with ANFIS model test errors, subsequently. It is found that the ANFIS model with root mean square (RMS) test errors of 4.79%, 5.04% and 11.39%, in fixed inlet conditions and local conditions and fixed outlet conditions, respectively, has superior performance in predicting the CHF than the test error obtained from MLP Neural Network in fixed inlet and outlet conditions, however, ANFIS also has acceptable result to predict CHF in fixed local conditions.
Directory of Open Access Journals (Sweden)
P. P. Bidzilya
2015-10-01
Full Text Available According to different authors, the representation of women in the structure of chronic heart failure (CHF ranges from 50% to 60%, however, in clinical studies the number of participants in the female reaches only 20–30%. Aim. To study age-related changes in the structural parameters of the heart and myocardial remodeling in CHF. 216 women of different age groups who have had CHF I–III functional class on the background of normal, overweight and abdominal obesity I–III degree were examined. Methods and results. Structural parameters of the heart and the condition of cardiac remodeling were estimated with echocardiography. Found that in CHF in women with overweight and obesity with age increasing is a more significant dilatation of cardiac chambers, myocardial hypertrophy of the left ventricle and the calcination of valve apparatus. In most cases myocardial remodeling were presented by concentric hypertrophy of the left ventricle. Conclusion. This demonstrates negative impact of increasing age on the restructuring of the heart in conditions of CHF in women with overweight and obesity.
International Nuclear Information System (INIS)
Fong, R.W.L.; McRae, G.A.; Coleman, C.E.; Nitheanandan, T.; Sanderson, D.B.
1999-10-01
In CANDU fuel channels, Zircaloy calandria tubes isolate the hot pressure tubes from the cool heavy water moderator. The heavy-water moderator provides a backup heat sink during some postulated loss-of-coolant accidents. The decay heat from the fuel is transferred to the moderator to ensure fuel channel integrity during emergencies. Moderator temperature requirements are specified to ensure that the transfer of decay heat does not exceed the critical heat flux (CHF) on the outside surface of the calandria tube. An enhanced CHF provides increases in safety margin. Pool boiling experiments indicate the CHF is enhanced with glass-peening of the outside surface of the calandria tubes. The objective of this study was to evaluate the surface characteristics of glass-peened tubes and relate these characteristics to CHF. The micro-topologies of the tube surfaces were analysed using stereo-pair micrographs obtained from scanning electron microscopy (SEM) and photogrammetry techniques. A linear relationship correlated the CHF as a function of the 'fractal' surface roughness of the tubes. (author)
Critical heat flux concerns during the flow instability phase of a DEGB LOCA
International Nuclear Information System (INIS)
Shadday, M.A. Jr.
1990-08-01
Arguments are presented that support the proposal that a separate burnout risk analysis, for the Flow Instability (FI) phase of a LOCA, not be required for reactor restart. With expected reactor power limits, flow instability will occur before critical heat flux (CHF). Since FI power limits preclude the occurrence of flow instability in a bounding accident, a DEGB LOCA, the risk of CHF and attendant burnout is negligible. A review of RDAP data revealed that in the past reactor assemblies operated at flow and power conditions similar to those expected in a LOCA without burnout occurring. This is strong bounding empirical evidence, without the scaling concerns of laboratory experiments. A bounding analysis of the influences of assembly non-idealities on CHF, power tilts, and channel eccentricity, is included. The margin between operating heat fluxes, during the postulated LOCA, and CHF was quantified by scoping calculations. Based on measured azimuthal power variations, the local heat flux would have to be more than 20 standard deviations above the calculated mean heat flux for CHF to occur
Prediction of critical heat flux using ANFIS
International Nuclear Information System (INIS)
Zaferanlouei, Salman; Rostamifard, Dariush; Setayeshi, Saeed
2010-01-01
The prediction of Critical Heat Flux (CHF) is essential for water cooled nuclear reactors since it is an important parameter for the economic efficiency and safety of nuclear power plants. Therefore, in this study using Adaptive Neuro-Fuzzy Inference System (ANFIS), a new flexible tool is developed to predict CHF. The process of training and testing in this model is done by using a set of available published field data. The CHF values predicted by the ANFIS model are acceptable compared with the other prediction methods. We improve the ANN model that is proposed by to avoid overfitting. The obtained new ANN test errors are compared with ANFIS model test errors, subsequently. It is found that the ANFIS model with root mean square (RMS) test errors of 4.79%, 5.04% and 11.39%, in fixed inlet conditions and local conditions and fixed outlet conditions, respectively, has superior performance in predicting the CHF than the test error obtained from MLP Neural Network in fixed inlet and outlet conditions, however, ANFIS also has acceptable result to predict CHF in fixed local conditions.
Radiologic evaluation of adriamycin induced toxic cardiomyopathy in childhood leukemia
International Nuclear Information System (INIS)
Kim, Young Joo; Moon, Young Hee; Kang, Kyung Jin; Kim, Ok Hwa; Kim, Choon Yul; Bahk, Yong Whee
1992-01-01
The cardiomyopathy associated with Adriamycin is frequently fatal and full clinical recovery is uncommon. To evaluate the radiological manifestation and the outcome of Adriamycin induced cardiac toxicity, we retrospectively reviewed the serial chest X-ray films of children treated with Adriamycin. Among 154 children with leukemia, fourteen patients developed clinical and radiologic evidence of congestive heart failure (CHF). Six out of 14 (43%) died of CHF within 2 weeks after attack and eight children survived after their acute episodes of CHF, were controlled following digoxin and diuretic therapy. Despite the improving clinical evidence of heart failure, the follow-up chest roentgenograms of these 8 children showed definite cardiomegaly as compared with the pre-treatment chest X-ray. Three children among 8 had minimal cardiomegaly and the remaining five children showed persistent, marked cardiomegaly during the period of 9-25 months of follow up. In summary, when CHF develops during chemotherapy in leukemic children, the possibility of Adriamycin induced cardiac toxicity should be suspected. Our findings showed that persistence of cardiomegaly represented significant cardiomyopathy despite clinical improvement of CHF
Azimuthal critical heat flux in narrow rectangular channels
Energy Technology Data Exchange (ETDEWEB)
Kim, Yong Hoon; Noh, Sang Woo; Kim, Sung Joong; Suh, Kune Y. [Seoul National University, Seoul (Korea, Republic of)
2003-07-01
Tests were conducted to examine the critical heat flux (CHF) on the one-dimensional downward heating rectangular channel having a narrow gap by changing the orientation of the copper test heater assembly in a pool of saturated water under the atmospheric pressure. The test parameters include both the gap sizes of 1, 2, 5 and 10mm, and the surface orientation angles from the downward-facing position (180{sup o}) to the vertical position (90{sup o}), respectively. Also, the CHF experiments were performed for pool boiling with varying heater surface orientations in the unconfined space at the atmospheric pressure using the rectangular test section. It was observed that the CHF generally decreases as the surface inclination angle increases and as the gap size decreases. In consistency with several studies reported in the literature, it was found that there exists a transition angle above which the CHF changes with a rapid slope. An engineering correlation is developed for the CHF during natural convective boiling in the inclined, confined rectangular channels with the aid of dimensional analysis.
Parametric trends analysis of the critical heat flux based on artificial neural networks
International Nuclear Information System (INIS)
Moon, S.K.; Baek, W.P.; Chang, S.H.
1996-01-01
Parametric trends of the critical heat flux (CHF) are analyzed by applying artificial neural networks (ANNs) to a CHF data base for upward flow of water in uniformly heated vertical round tubes. The analyses are performed from three viewpoints, i.e., for fixed inlet conditions, for fixed exit conditions, and based on local conditions hypothesis. Katto's and Groeneveld et al. dimensionless parameters are used to train the ANNs with the experimental CHF data. The trained ANNs predict the CHF better than any other conventional correlations, showing RMS errors of 8.9%, 13.1% and 19.3% for fixed inlet conditions, for fixed exit conditions, and for local conditions hypothesis, respectively. The parametric trends of the CHF obtained from those trained ANNs show a general agreement with previous understanding. In addition, this study provides more comprehensive information and indicates interesting points for the effects of the tube diameter, the heated length, and the mass flux. It is expected that better understanding of the parametric trends is feasible with an extended data base. (orig.)
Analysis of N-terminal pro-brain natriuretic peptide levels in patients with chronic heart failure
International Nuclear Information System (INIS)
Fu Xiao; Zhang Xingping; Zhou Kejian
2011-01-01
To investigate the changes and its clinical significance of serum N-terminal pro-brain natriuretic peptide (NT-proBNP) levels in patients with chronic heart failure(CHF), 128 patients with decompensated CHF and 20 patients without structural heart disease were selected as CHF and control group. All subjects were evaluated heart function by New York Heart Association (NYHA) class. The serum NT-proBNP levels were assayed by electrochemiluminescence double antibody sandwich immunoassay. Left ventricular ejection fraction (LVEF) was detected by color Doppler ultrasound. The results showed that the NT-proBNP levels in CHF group were significantly higher than that of in the control group (P<0.05). Further, the NT-proBNP levels showed an increased tendency accompanied by the severity of heart failure (P<0.05) and lowering of LVEF (r=-0.595, P<0.05). The serum NT-proBNP levels can reflect the state of cardiac function in patients with decompensated DHF, and useful in the diagnosis and severity assessment of CHF. (authors)
Incici, Erol; Matuliene, Giedre; Hüsler, Jürg; Salvi, Giovanni E; Pjetursson, Bjarni; Brägger, Urs
2009-07-01
To assess retrospectively the cumulative costs for the long-term oral rehabilitation of patients with birth defects affecting the development of teeth. Patients with birth defects who had received fixed reconstructions on teeth and/or implants > or =5 years ago were asked to participate in a comprehensive clinical, radiographic and economic evaluation. From the 45 patients included, 18 were cases with a cleft lip and palate, five had amelogenesis/dentinogenesis imperfecta and 22 were cases with hypodontia/oligodontia. The initial costs for the first oral rehabilitation (before the age of 20) had been covered by the Swiss Insurance for Disability. The costs for the initial rehabilitation of the 45 cases amounted to 407,584 CHF (39% for laboratory fees). Linear regression analyses for the initial treatment costs per replaced tooth revealed the formula 731 CHF+(811 CHF x units) on teeth and 3369 CHF+(1183 CHF x units) for reconstructions on implants (Phealthy teeth, fewer tooth units need to be replaced and the cumulative long-term costs seem to be similar compared with cases restored on teeth.
An influence of physical rehabilitation on living standards of children with chronic heart failure
Directory of Open Access Journals (Sweden)
Maryana Chekhovska
2017-08-01
Full Text Available Purpose: to determine the impact of the developed program of physical rehabilitation on the quality of life of school-age children with chronic heart failure (CHF I–IIA stages. Material & Methods: analysis, generalization of scientific and methodological literature, Internet, survey method, methods of mathematical statistics. The study was conducted on the basis of the West-Ukrainian specialized children's medical center (Lviv. The experiment involved 34 school-age children with CHF I–IIA stages. Result: the evaluation of the quality of life of school age children with EH with CHF I–IIA stages showed a significant improvement in the four blocks. The physical functioning according to the parents' information had the greatest improvement. Despite the increase in the indicator of the functioning of the child in school, it remains low. Improving emotional and social functioning contributes to the social adaptation of children in society. The positive and negative dynamics of QoL of children of CHF for block indicators is not reliably confirmed. Conclusion: quality of life in children with CHF is an important integral indicator.
Downregulation of aquaporin-1 in alveolar microvessels in lungs adapted to chronic heart failure
DEFF Research Database (Denmark)
Müllertz, Katrine M; Strøm, Claes; Trautner, Simon
2011-01-01
The threshold pressure for lung edema formation is increased in severe chronic heart failure (CHF) due to reduced microvascular permeability. The water channel aquaporin-1 (AQP1) is present in the pulmonary microvascular endothelium, and a number of studies suggest the importance of AQP1 as a mol......The threshold pressure for lung edema formation is increased in severe chronic heart failure (CHF) due to reduced microvascular permeability. The water channel aquaporin-1 (AQP1) is present in the pulmonary microvascular endothelium, and a number of studies suggest the importance of AQP1...... as a molecular determinant of pulmonary microvascular water transport. The present study examined the abundance and localization of AQP1 in lungs from rats with CHF. We used two different models of CHF: ligation of the left anterior descending coronary artery (LAD ligation) and aorta-banding (AB). Sham......-operated rats served as controls. Echocardiographic verification of left ventricular dysfunction, enhanced left ventricular end-diastolic pressure, and right ventricular hypertrophy confirmed the presence of CHF. Western blotting of whole-lung homogenates revealed significant downregulation of AQP1 in LAD...
Kyrzopoulos, Stamos; Adamopoulos, Stamatis; Parissis, John T; Rassias, John; Kostakis, George; Iliodromitis, Efstathios; Degiannis, Dimitrios; Kremastinos, Dimitrios Th
2005-03-30
Plasma B-type natriuretic peptide (BNP) and interleukin 6 (IL-6) levels have recently been demonstrated as significant neurohormonal markers associated with the progression of chronic heart failure (CHF). Additionally, clinical studies have shown that the calcium sensitizer, levosimendan, beneficially affects the central hemodynamics of CHF patients and improves their long-term prognosis. This study investigates whether levosimendan-induced hemodynamic improvement of CHF patients is related to the respective changes of NT-proBNP and IL-6 levels. Circulating levels of NT-pro BNP and IL-6 were measured by enzyme-linked immunosorbent assay (ELISA) in 12 patients with decompensated advanced CHF at baseline, immediately after the end of a 24-h levosimendan infusion and 72 h after the initiation of treatment. Hemodynamic parameters of patients (pulmonary wedge and pulmonary artery pressure (PAP), systemic and pulmonary vascular resistance (PVR), stroke volume, and cardiac output and index) were also monitored during the same period. NT-proBNP and IL-6 levels were significantly reduced in severe CHF patients within 72 h after the initiation of levosimendan treatment (pNT-proBNP levels and the respective reduction of pulmonary wedge pressure (r(s)=0.65, pBNP and IL-6 levels may be useful biochemical markers related with the levosimendan-induced improvement in central hemodynamics and the clinical status of decompensated advanced CHF patients.
I farmaci per lo scompenso cardiaco: criteri di scelta razionale e costo-efficace
Directory of Open Access Journals (Sweden)
Francesco Vittorio Costa
2005-09-01
Full Text Available Chronic heart failure (CHF is the final phase of many common cardiovascular diseases. Consequently, it represents a frequent clinical condition: it’s estimated that in developed countries, Italy included, its prevalence exceeds 3%. CHF is also burdensome from an economical point of view, as it absorbs more than 2% of the Italian total health care budget. The main cost driver in CHF, accounting for approximately two thirds of its total expense, is represented by hospital admissions for relapse. The most frequent reason for relapse, in turn, is inadequate treatment, intended both as low patient compliance to prescribed drug regimens and as inappropriate prescribing. Evidence-based guidelines for the optimal pharmacological treatment of CHF have been developed and are constantly updated, and it’s demonstrated that the stricter the adherence to these recommendations, the better the clinical and economic outcomes. Pharmacoeconomic studies conducted on the use of ACE-inhibitors and beta-blockers, in particular, have shown that correct therapeutic strategies can be cost-saving in CHF management, besides providing important clinical benefits. The expansion of generic drug market has brought by a reduction in pharmaceutical prices, allowing to offer the benefits of these highly effective, and cost-effective, treatments for CHF to a larger number of patients, without increasing the global pharmaceutical expense, but probably reducing the total economical burden of the disease.
Critical heat flux and flow pattern for water flow in annular geometry
International Nuclear Information System (INIS)
Park, J.-W.; Baek, W.-P.; Chang, S.H.
1997-01-01
An experimental study on critical heat flux (CHF) and two-phase flow visualization has been performed for water flow in internally-heated, vertical, concentric annuli under near atmospheric pressure. Tests have been done under stable forced-circulation, upward and downward flow conditions with three test sections of relatively large gap widths (heated length = 0.6 m, inner diameter 19 mm, outer diameter = 29, 35 and 51 mm). The outer wall of the test section was made up of the transparent Pyrex tube to allow the observation of flow patterns near the CHF occurrence. The CHF mechanism was changed in the order of flooding, churn-to-annular flow transition and local dryout under a large bubble in churn flow as the flow rate was increased from zero to higher values. Observed parametric trends are consistent with the previous understanding except that the CHF for downward flow is considerably lower than that for the upward flow. In addition to the experiment, selected CHF correlations for annuli are assessed based on 1156 experimental data from various sources. The Doerffer et al. (1994); Barnett (1966); Jannsen and Kervinen (1963); Levitan and Lantsman (1977) correlations show reasonable predictions for wide parameter ranges, among which the Doerffer et al. (1994) correlation shows the widest parameter ranges and a possibility of further improvement. However, there is no correlation predicting the low-pressure, low-flow CHF satisfactorily. (orig.)
Directory of Open Access Journals (Sweden)
Machado Cristiano V
2011-06-01
Full Text Available Abstract Background Left ventricular ejection fraction (LVEF has been considered a major determinant of early outcome in acute myocardial infarction (AMI. Myocardial performance index (MPI has been associated to early evolution in AMI in a heterogeneous population, including non ST-elevation or previous AMI. Left atrial volume has been related with late evolution after AMI. We evaluated the independent role of clinical and echocardiographic variables including LVEF, MPI and left atrial volume in predicting early in-hospital congestive heart failure (CHF specifically in patients with a first isolated ST-elevation AMI. Methods Echocardiography was performed within 30 hours of chest pain in 95 patients with a first ST-elevation AMI followed during the first week of hospitalization. Several clinical and echocardiographic variables were analyzed. CHF was defined as Killip class ≥ II. Multivariate regression analysis was used to select independent predictor of in-hospital CHF. Results Early in-hospital CHF occurred in 29 (31% of patients. LVEF ≤ 0.45 was the single independent and highly significant predictor of early CHF among other clinical and echocardiographic variables (odds ratio 17.0; [95% CI 4.1 - 70.8]; p Conclusion For patients with first, isolated ST-elevation AMI, LVEF assessed by echocardiography still constitutes a strong and accurate independent predictor of early in-hospital CHF, superior to isolated MPI and left atrial volume in this particular subset of patients.
Directory of Open Access Journals (Sweden)
Shafazand Masoud
2012-03-01
Full Text Available Abstract Background Chronic heart failure (CHF is a major public health problem characterised by progressive deterioration with disabling symptoms and frequent hospital admissions. To influence hospitalisation rates it is crucial to identify precipitating factors. To characterise patients with CHF who seek an emergency department (ED because of worsening symptoms and signs and to explore the reasons why they are admitted to hospital. Method Patients (n = 2,648 seeking care for dyspnoea were identified at the ED, Sahlgrenska University Hospital/Östra. Out of 2,648 patients, 1,127 had a previous diagnosis of CHF, and of these, 786 were included in the present study with at least one sign and one symptom of worsening CHF. Results Although several of the patients wanted to go home after acute treatment in the ED, only 2% could be sent home. These patients were enrolled in an interventional study, which evaluated the acute care at home compared to the conventional, in hospital care. The remaining patients were admitted to hospital because of serious condition, including pneumonia/respiratory disease, myocardial infarction, pulmonary oedema, anaemia, the need to monitor cardiac rhythm, pathological blood chemistry and difficulties to communicate. Conclusion The vast majority of patients with worsening CHF seeking the ED required hospital care, predominantly because of co-morbidities. Patients with CHF with symptomatic deterioration may be admitted to hospital without additional emergency room investigations.
Critical Heat Flux Experiments on the Reactor Vessel Wall Using 2-D Slice Test Section
International Nuclear Information System (INIS)
Jeong, Yong Hoon; Chang, Soon Heung; Baek, Won-Pil
2005-01-01
The critical heat flux (CHF) on the reactor vessel outer wall was measured using the two-dimensional slice test section. The radius and the channel area of the test section were 2.5 m and 10 cm x 15 cm, respectively. The flow channel area and the heater width were smaller than those of the ULPU experiments, but the radius was greater than that of the ULPU. The CHF data under the inlet subcooling of 2 to 25 deg. C and the mass flux 0 to 300 kg/m 2 .s had been acquired. The measured CHF value was generally slightly lower than that of the ULPU. The difference possibly comes from the difference of the test section material and the thickness. However, the general trend of CHF according to the mass flux was similar with that of the ULPU. The experimental CHF data were compared with the predicted values by SULTAN correlation. The SULTAN correlation predicted well this study's data only for the mass flux higher than 200 kg/m 2 .s, and for the exit quality lower than 0.05. The local condition-based correlation was developed, and it showed good prediction capability for broad quality (-0.01 to 0.5) and mass flux ( 2 .s) conditions with a root-mean-square error of 2.4%. There were increases in the CHF with trisodium phosphate-added water
Experimental Investigation of Pool Boiling for Single and Double Heaters Using Printed Circuit Board
International Nuclear Information System (INIS)
Han, Won Seok; Lee, Jae Young
2012-01-01
Over the past several decades, a considerable number of studies have been conducted on boiling heat transfer in pool boiling. Boiling heat transfer is used in a variety of cooling applications, such as heat exchangers, high powered electronics, and nuclear reactors. Nucleate boiling is one of the most efficient heat transfer mechanisms in boiling regime, but it is imperative that the critical heat flux(CHF) should not be exceeded. CHF phenomenon leads to a dramatic rise in wall temperature, decreased heat transfer, and material failure. Although numerous attempts have been made by researchers to demonstrate the CHF, there is little agreement with the CHF mechanism. In recent years, many researchers have been focusing on surface condition using nanoparticles and surface enhancements, such as a micro structure and artificial cavities, due to enhancement of the CHF point. Cooke and Kandlikar used chips etched with microchannels to prove that these structure has the most enhancement effect. They found that the most efficient boiling surface is with a larger channel size and deep etch. The purpose of this paper is to evaluate the heat transfer and CHF of double heaters on printed circuit board(PCB) in pool boiling. In addition, bubble dynamics of nucleate boiling were observed with high speed observation on single and double heaters using PCB heater
Energy Technology Data Exchange (ETDEWEB)
Cho, Seok; Chun, Se Young; Moon, Sang Ki; Baek, Won Pil
2003-11-01
KAERI has performed an experimental study of water Critical Heat Flux (CHF) under zero flow conditions with a non-uniformly heated 3 by 3 rod bundle. Experimental conditions are in the range of a system pressure from 0.5 to 15.0 MPa and inlet water subcooling enthalpies from 67.5 to 351.5 kJ/kg. The test section used in the present experiments consisted of a vertical flow channel, upper and lower plenums, and a non-uniformly heated 3 by 3 rod bundle. The experimental results show that the CHFs in low-pressure conditions are somewhat scattered within a narrow range. As the system pressure increases, however, the CHFs show a consistent parametric trend. The CHFs occur in the upper region of the heated section, but the vertical distances of the detected CHFs from the bottom of the heated section are reduced as the system pressure increases. Even though the effects of the inlet water subcooling enthalpies and system pressure in the flooding CHF are relatively smaller than those of the flow boiling CHF, the CHF increases by increasing the inlet water subcooling enthalpies. Several existing correlations for the countercurrent flooding CHF based on Wallis's flooding correlation and Kutateladze's criterion for the onset of flooding are compared with the CHF data obtained in the present experiments to examine the applicability of the correlations.
Modeling Ne-21 NMR parameters for carbon nanosystems
Czech Academy of Sciences Publication Activity Database
Kupka, T.; Nieradka, M.; Kaminský, Jakub; Stobinski, L.
2013-01-01
Roč. 51, č. 10 (2013), s. 676-681 ISSN 0749-1581 R&D Projects: GA ČR GAP208/11/0105; GA MŠk(CZ) LH11033 Grant - others:AV ČR(CZ) M200551205 Institutional support: RVO:61388963 Keywords : Ne-21 NMR * GIAO NMR * molecular modeling * carbon nanostructures Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.559, year: 2013
Chronic heart failure modifies respiratory mechanics in rats: a randomized controlled trial
Directory of Open Access Journals (Sweden)
Deise M. Pacheco
2016-01-01
Full Text Available ABSTRACT Objective To analyze respiratory mechanics and hemodynamic alterations in an experimental model of chronic heart failure (CHF following myocardial infarction. Method Twenty-seven male adult Wistar rats were randomized to CHF group (n=12 or Sham group (n=15. Ten weeks after coronary ligation or sham surgery, the animals were anesthetized and submitted to respiratory mechanics and hemodynamic measurements. Pulmonary edema as well as cardiac remodeling were measured. Results The CHF rats showed pulmonary edema 26% higher than the Sham group. The respiratory system compliance (Crs and the total lung capacity (TLC were lower (40% and 27%, respectively in the CHF rats when compared to the Sham group (P<0.01. There was also an increase in tissue resistance (Gti and elastance (Hti (28% and 45%, respectively in the CHF group. Moreover, left ventricular end-diastolic pressure was higher (32 mmHg vs 4 mmHg, P<0.01, while the left ventricular systolic pressure was lower (118 mmHg vs 130 mmHg, P=0.02 in the CHF group when compared to the control. Pearson’s correlation coefficient showed a negative association between pulmonary edema and Crs (r=–0.70, P=0.0001 and between pulmonary edema and TLC (r=–0.67,P=0.0034. Pulmonary edema correlated positively with Gti (r=0.68, P=0.001 and Hti (r=0.68, P=0.001. Finally, there was a strong positive relationship between pulmonary edema and heart weight (r=0.80, P=0.001. Conclusion Rats with CHF present important changes in hemodynamic and respiratory mechanics, which may be associated with alterations in cardiopulmonary interactions.
Albackr, Hanan B; Alhabib, Khalid F; Ullah, Anhar; Alfaleh, Hussam; Hersi, Ahmad; Alshaer, Fayez; Alnemer, Khalid; Al Saif, Shukri; Taraben, Amir; Kashour, Tarek
2013-11-01
The aim of this study was to assess the prevalence, clinical features, and in-hospital outcomes of heart failure in patients with acute coronary syndrome (ACS). The Saudi Project for Assessment of Coronary Events recruited patients admitted with ACS from 17 hospitals in Saudi Arabia from 2005 to 2007. The outcomes of ACS patients with congestive heart failure (CHF) compared with those without CHF were analyzed. A total of 4523 patients with ACS were identified, of whom 905 (20%) had CHF. Compared with no CHF, patients with CHF were older (62±13.1 vs. 57±12.9 years; P=0.001), less likely to be men (70 vs. 79%; P=0.001), likely to present with non-ST-segment elevation myocardial infarction (48 vs. 36%; P=0.001), likely to have diabetes (71 vs. 54%; P=0.001), hypertension (64 vs. 54%; P=0.001) and previous history of coronary artery disease (53 vs. 43%; P=0.001), and likely to have significant left ventricular systolic dysfunction (left ventricular ejection fraction coronary intervention (19 vs. 50%; P=0.001). Adjusted in-hospital mortality and cardiogenic shock were higher in the CHF group (odds ratio 4.43, 95% confidence interval 2.52-7.78; and odds ratio 3.51, 95% confidence interval 2.23-5.52), respectively. ACS patients with CHF in the Saudi Project for Assessment of Coronary Events were older, more likely to have more cardiac risk factors, and less likely to be treated with optimum medical treatment on admission. These findings were associated with higher incidence of their in-hospital adverse outcomes. More aggressive treatment is warranted to improve prognosis.
[Matrix metalloproteinases and their inhibitors in lung cancer with malignant pleural effusion].
Moche, M; Hui, D S C; Huse, K; Chan, K S; Choy, D K L; Scholz, G H; Gosse, H; Winkler, J; Schauer, J; Sack, U; Hoheisel, G
2005-08-01
Matrix metalloproteinases (MMP) and tissue inhibitors of metalloproteinases (TIMP) play a crucial role in physiological and pathological matrix turnover. This study aimed to determine the occurrence of MMP and TIMP in lung cancer patients with malignant pleural effusions (CA). MMP-1, MMP-2, MMP-3, MMP-8, MMP-9, TIMP-1, and IMP-2 oncentrations were determined by ELISA and zymography in pleural effusions and plasma of 31 CA and 14 congestive heart failure (CHF) patients and in plasma of 18 healthy controls (CON). MMP-2, TIMP-1, and TIMP-2 ELISA-concentrations were increased in CA pleural fluid vs. CA plasma (p < 0.005, p < 0.005, p < 0.05), in contrast to MMP-9 being higher in plasma (p < 0.005). Pleural fluid MMP-1 and MMP-8 were increased in CA vs. CHF (p < 0.05, p < 0.005). MMP and TIMP plasma concentrations were not different in CA vs. CHF, but MMP-9, TIMP-1, and TIMP-2 were increased vs. CON (p < 0.005, each). Gelatine zymography MMP-9/MMP-2 ratios were increased in CA plasma vs. effusion fluid (p < 0.005), in CA vs. CHF plasma, CA vs. CHF effusions (p < 0.005 each), and in CA vs. CON plasma (p < 0.05). MMP-2, TIMP-1, and TIMP-2 accumulate in the pleural compartment in CA and CHF, probably reflecting an unspecific pleural reaction. MMP-1 and MMP-8 are increased in cellular rich CA pleural effusions only. The determination of MMP-9/MMP-2 ratios in pleural fluid may contribute to differentiate CHF from CA effusions.
Chen, Pingan; Li, Shaonan; Lei, Xiaoming; Liu, Zhen; Wu, Daihong; Luo, Yi; Xu, Dingli
2015-08-01
In chronic heart failure (CHF) patients with type 2 diabetes mellitus (T2DM), the role of thyroid hormone (TH) in predicting CHF severity and prognosis is unclear. The authors therefore investigated the role of TH in predicting CHF severity and prognosis in these specific patients. A total of 224 CHF patients (114 with T2DM) over a mean follow-up time of 6.56 ± 0.18 months were studied. TH, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and other parameters were measured. Free triiodothyronine (FT3) levels were lower in the T2DM group compared with the nondiabetes group (P = 0.026) and higher in the New York Heart Association (NYHA) I group than in the NYHA III and IV groups (both P < 0.05). Compared with the low NT-proBNP group, the high NT-proBNP group had lower FT3 levels (P < 0.01). NT-proBNP correlated with NYHA classes (r = 0.541, P < 0.001), and inversely correlated with left ventricular ejection fraction (r = -0.431, P < 0.001) and FT3 levels (r = -0.335, P < 0.001). In multiple linear regression analysis, NT-proBNP was significantly correlated with NYHA classes (P < 0.001), left ventricular ejection fraction (P < 0.001) and FT3 (P = 0.004). Kaplan-Meier curves showed that the low FT3 group had an increased rate of short-term adverse outcomes of CHF (log rank, χ = 9.794, P = 0.002). FT3 levels are associated with the severity of CHF and seem to reflect short-term outcomes in CHF patients with T2DM.
Dalla Libera, Luciano; Ravara, Barbara; Volterrani, Maurizio; Gobbo, Valerio; Della Barbera, Mila; Angelini, Annalisa; Danieli Betto, Daniela; Germinario, Elena; Vescovo, Giorgio
2004-01-01
Muscle atrophy is a determinant of exercise capacity in heart failure (CHF). Myocyte apoptosis, triggered by tumor necrosis factor-alpha (TNF-alpha) or its second messenger sphingosine (SPH), is one of the causes of atrophy. Growth hormone (GH) improves hemodynamic and cardiac trophism in several experimental models of CHF, but its effect on skeletal muscle in CHF is not yet clear. We tested the hypothesis that GH can prevent skeletal muscle apoptosis in rats with CHF. CHF was induced by injecting monocrotaline. After 2 wk, 2 groups of rats were treated with GH (0.2 mg.kg(-1).day(-1) and 1.0 mg.kg(-1).day(-1)) subcutaneously. A third group of controls had saline. After 2 additional weeks, rats were killed. Tibialis anterior cross-sectional area, myosin heavy chain (MHC) composition, and a study on myocyte apoptosis and serum levels of TNF-alpha and SPH were carried out. The number of apoptotic nuclei, muscle atrophy, and serum levels of TNF-alpha and SPH were decreased with GH at high but not at low doses compared with CHF rats. Bcl-2 was increased, whereas activated caspases and bax were decreased. The MHC pattern in GH-treated animals was similar to that of controls. Monocrotaline slowed down both contraction and relaxation but did not affect specific tetanic force, whereas absolute force was decreased. GH treatment restored contraction and relaxation to control values and brought muscle mass and absolute twitch and tetanic tension to normal levels. These findings may provide an insight into the therapeutic strategy of GH given to patients with CHF to improve exercise capacity.
Bidzilya, P. P.
2015-01-01
According to different authors, the representation of women in the structure of chronic heart failure (CHF) ranges from 50% to 60%, however, in clinical studies the number of participants in the female reaches only 20–30%. Aim. To study age-related changes in the structural parameters of the heart and myocardial remodeling in CHF. 216 women of different age groups who have had CHF I–III functional class on the background of normal, overweight and abdominal obesity I–III degree were examin...
International Nuclear Information System (INIS)
Narita, Michihiro; Kurihara, Tadashi; Sindoh, Takashi; Sawada, Yoshihiro; Honda, Minoru
1998-01-01
We performed 123 I-BMIPP (BMIPP) imaging in order to clarify the characteristics of fatty acid metabolism and its effect on prognosis in patients with congestive heart failure (CHF) without coronary artery disease. We studied 15 normal subjects and 42 patients with CHF (idiopathic dilated cardiomyopathy; 24, hypertensive heart disease; 12, valvular heart disease; 6). We obtained cardiac imaging with BMIPP and 201 Tl at rest on separate days before discharge. Using whole body imaging, the ratio of cardiac uptake of the isotope to total injected dose was calculated (%Uptake). We calculated the cardiac uptake ratio of BMIPP (%Uptake of BMIPP divided by %Uptake of 201 Tl), percent washout of BMIPP from the heart over 3 hours and unhomogeneity of myocardial distribution of BMIPP (coefficient of variation of BMIPP, CV) as scintigraphic parameters. Cardiac events were defined as cardiac death or deterioration of CHF which requiring readmission. Uptake ratio (CHF; 0.91±0.17, normal; 1.10±0.09, p=0.0000) and CV (CHF; 20±5, normal; 16±5, p=0.0385) were different significantly between CHF and normal subjects. During the follow-up period of 27.2±14.4 months (4.5-53.5 months) cardiac events developed in 15 patients (cardiac death; 8, deterioration of CHF; 7). In univariate analysis, % uptake of 201 Tl, uptake ratio, % FS, serum norepinephrine level and serum renin activity were different significantly between event and event-free groups. Cox proportional hazard analysis showed that the uptake ratio (p=0.0000) and age (p=0.018) were independent predictors of cardiac events. In patients with uptake ratio less than 0.88, relative risks of cardiac events was 23.7 times greater than in patients with uptake ratio more than 0.89. These data suggested that in patients with CHF fatty acid metabolism was deteriorated and cardiac uptake of BMIPP was a strong and independent predictor of long-term prognosis in patients with heart failure. (author)
Enhanced activation of RVLM-projecting PVN neurons in rats with chronic heart failure.
Xu, Bo; Zheng, Hong; Patel, Kaushik P
2012-04-15
Previous studies have indicated that there is increased activation of the paraventricular nucleus (PVN) in rats with chronic heart failure (CHF); however, it is not clear if the preautonomic neurons within the PVN are specifically overactive. Also, it is not known if these neurons have altered responses to baroreceptor or osmotic challenges. Experiments were conducted in rats with CHF (6-8 wk after coronary artery ligation). Spontaneously active neurons were recorded in the PVN, of which 36% were antidromically activated from the rostral ventrolateral medulla (RVLM). The baseline discharge rate in RVLM-projecting PVN (PVN-RVLM) neurons from CHF rats was significantly greater than in sham-operated (sham) rats (6.0 ± 0.6 vs. 2.6 ± 0.3 spikes/s, P neurons by 80% in CHF rats compared with 37% in sham rats. Fifty-two percent of spontaneously active PVN-RVLM neurons responded to changes in the mean arterial pressure (MAP). The changes in discharge rate in PVN-RVLM neurons after a reduction in MAP (+52 ± 7% vs. +184 ± 61%) or an increase in MAP (-42 ± 8% vs. -71 ± 6%) were significantly attenuated in rats with CHF compared with sham rats. Most PVN-RVLM neurons (63%), including all barosensitive PVN-RVLM neurons, were excited by an internal carotid artery injection of hypertonic NaCl (2.1 osmol/l), whereas a smaller number (7%) were inhibited. The increase in discharge rate in PVN-RVLM neurons to hypertonic stimulation was significantly enhanced in rats with CHF compared with sham rats (134 ± 15% vs. 92 ± 13%). Taken together, these data suggest that PVN-RVLM neurons are more active under basal conditions and this overactivation is mediated by an enhanced glutamatergic tone in rats with CHF. Furthermore, this enhanced activation of PVN-RVLM neurons may contribute to the altered responses to baroreceptor and osmotic challenges observed during CHF.
Directory of Open Access Journals (Sweden)
Laura A. León
2017-07-01
Full Text Available The role of serotonin (5-hydroxytryptamine [5-HT] and 5-HT2A receptors in anxiety has been extensively studied, mostly without considering individual differences in trait anxiety. Our laboratory developed two lines of animals that are bred for high and low freezing responses to contextual cues that are previously associated with footshock (Carioca High-conditioned Freezing [CHF] and Carioca Low-conditioned Freezing [CLF]. The present study investigated whether ketanserin, a preferential 5-HT2A receptor blocker, exerts distinct anxiety-like profiles in these two lines of animals. In the first experiment, the animals received a systemic injection of ketanserin and were exposed to the elevated plus maze (EPM. In the second experiment, these two lines of animals received microinjections of ketanserin in the infralimbic (IL and prelimbic (PL cortices and were exposed to either the EPM or a contextual fear conditioning paradigm. The two rat lines exhibited bidirectional effects on anxiety-like behavior in the EPM and opposite responses to ketanserin. Both systemic and intra-IL cortex injections of ketanserin exerted anxiolytic-like effects in CHF rats but anxiogenic-like effects in CLF rats. Microinjections of ketanserin in the PL cortex also exerted anxiolytic-like effects in CHF rats but had no effect in CLF rats. These results suggest that the behavioral effects of 5-HT2A receptor antagonism might depend on genetic variability associated with baseline reactions to threatening situations and 5-HT2A receptor expression in the IL and PL cortices.Highlights-CHF and CLF rats are two bidirectional lines that are based on contextual fear conditioning.-CHF rats have a more “anxious” phenotype than CLF rats in the EPM.-The 5-HT2A receptor antagonist ketanserin had opposite behavioral effects in CHF and CLF rats.-Systemic and IL injections either decreased (CHF or increased (CLF anxiety-like behavior.-PL injections either decreased (CHF anxiety
Energy Technology Data Exchange (ETDEWEB)
Narita, Michihiro; Kurihara, Tadashi; Sindoh, Takashi; Sawada, Yoshihiro; Honda, Minoru [Sumitomo Hospital, Osaka (Japan)
1998-04-01
We performed {sup 123}I-BMIPP (BMIPP) imaging in order to clarify the characteristics of fatty acid metabolism and its effect on prognosis in patients with congestive heart failure (CHF) without coronary artery disease. We studied 15 normal subjects and 42 patients with CHF (idiopathic dilated cardiomyopathy; 24, hypertensive heart disease; 12, valvular heart disease; 6). We obtained cardiac imaging with BMIPP and {sup 201}Tl at rest on separate days before discharge. Using whole body imaging, the ratio of cardiac uptake of the isotope to total injected dose was calculated (%Uptake). We calculated the cardiac uptake ratio of BMIPP (%Uptake of BMIPP divided by %Uptake of {sup 201}Tl), percent washout of BMIPP from the heart over 3 hours and unhomogeneity of myocardial distribution of BMIPP (coefficient of variation of BMIPP, CV) as scintigraphic parameters. Cardiac events were defined as cardiac death or deterioration of CHF which requiring readmission. Uptake ratio (CHF; 0.91{+-}0.17, normal; 1.10{+-}0.09, p=0.0000) and CV (CHF; 20{+-}5, normal; 16{+-}5, p=0.0385) were different significantly between CHF and normal subjects. During the follow-up period of 27.2{+-}14.4 months (4.5-53.5 months) cardiac events developed in 15 patients (cardiac death; 8, deterioration of CHF; 7). In univariate analysis, % uptake of {sup 201}Tl, uptake ratio, % FS, serum norepinephrine level and serum renin activity were different significantly between event and event-free groups. Cox proportional hazard analysis showed that the uptake ratio (p=0.0000) and age (p=0.018) were independent predictors of cardiac events. In patients with uptake ratio less than 0.88, relative risks of cardiac events was 23.7 times greater than in patients with uptake ratio more than 0.89. These data suggested that in patients with CHF fatty acid metabolism was deteriorated and cardiac uptake of BMIPP was a strong and independent predictor of long-term prognosis in patients with heart failure. (author)
Pengembangan Aplikasi @Webplan untuk Perhitungan Waktu Standar pada Proses Perakitan Manual
Directory of Open Access Journals (Sweden)
Agus Sutanto
2010-04-01
Full Text Available Karya tulis ini berkenaan dengan pengembangan perangkat lunak berbasiskan Web untuk perhitungan waktu kerja standar yang merupakan sebuah modul tambahan pada aplikasi perangkat lunak untuk perancangan sistem kerja berbasiskan Web atau yang diberi nama @WebPlan® yang sudah dikembangkan oleh penulis. @WebPlan ini merupakan integrasi dari beberapa modul untuk perancangan tataletak dan disain stasiun kerja secara virtual 3D. Beberapa modul sudah dirancang sebelumnya yaitu modul untuk visualisasi produk dan strukturnya sehingga dimungkinkan visualisasi yang interaktif untuk proses perakitannya. Sedangkan modul utama dalam @WebPlan ini adalah 3D Facilities Layout dan disain/layout stasiun kerja. Untuk tujuan ini juga sudah dibuat beberapa alat bantu yaitu model manusia 3D untuk beberapa persentil dan beberapa analisa dan checklist ergonomi. Pengembangan aplikasi @WebPlan ini untuk perhitungan waktu standar pada produksi serial merupakan suatu yang sangat diperlukan untuk menentukan waktu total yang diperlukan dalam memproduksi/merakit sebuah produk. Waktu total ini merupakan data penting dalam membuat konfigurasi stasiun kerja untuk pembuatan produk. Metoda Pengukuran waktu perakitan yang dipakai dalam hal ini adalah MTM-UAS (Universal Analysing System yang sangat cocok untuk perakitan manual. Hasil perhitungan waktu proses perakitan ini divalidasi dengan proses perakitan yang sebenarnya dan tidak menunjukkan perbedaan harga yang cukup signifikan. Beberapa kemudahan yang didapat pada metoda ini adalah MTM-UAS menggabungkan beberapa gerakan dan tidak terlalu detail dibandingkan metoda pengukuran waktu lainnya. Akan tetapi memiliki hasil yang cukup mendekati hasil yang sebenarnya. Modul aplikasi perhitungan waktu standar ini merupakan bagian yang diintergrasikan nantinya dalam perancangan tataletak dan stasiun kerja secara virtual 3D
A theoretical prediction of critical heat flux in saturated pool boiling during power transients
International Nuclear Information System (INIS)
Pasamehmetoglu, K.O.; Nelson, R.A.; Gunnerson, F.S.
1987-01-01
Understanding and predicting critical heat flux (CHF) behavior during steady-state and transient conditions is of fundamental interest in the design, operation, and safety of boiling and two-phase flow devices. Presented within this paper are the results of a comprehensive theoretical study specifically conducted to model transient CHF behavior in saturated pool boiling. Thermal energy conduction within a heating element and its influence on the CHF are also discussed. The resultant theory provides new insight into the basic physics of the CHF phenomenon and indicates favorable agreement with the experimental data from cylindrical heaters with small radii. However, the flat-ribbon heater data compared poorly with the present theory, although the general trend was predicted. Finally, various factors that affect the discrepency between the data and the theory are listed
Critical heat flux experimental facility using Freon R-134a fluid
Energy Technology Data Exchange (ETDEWEB)
Hong, Sung Deok; Chung, C. H.; Kim, B. D. [Korea Atomic Energy Research Institute, Taejeon (Korea)
2000-02-01
A CHF experimental loop using Freon R-134a as a working fluid has been designed and built to facilitate modeling of high pressure/temperature water CHF experiments. This loop was designed to operate at 4 MPa, 100 deg C with the maximum flow rate of 2.5 kg/s. The detailed technical specification and operating procedure of the loop are described together with comments on the performance and limitations of the loop. A series of CHF experiment was carried out in a vertical round tube and the fluid-to-fluid modeling techniques are applied for it's validity for the high temperature/pressure reactor conditions. The experimental range covered all the application ranges of CHF correlations developed for both PWR and PHWR. 28 refs., 9 figs., 5 tabs. (Author)
An Automated Approach for Ranking Journals to Help in Clinician Decision Support
Jonnalagadda, Siddhartha R.; Moosavinasab, Soheil; Nath, Chinmoy; Li, Dingcheng; Chute, Christopher G.; Liu, Hongfang
2014-01-01
Point of care access to knowledge from full text journal articles supports decision-making and decreases medical errors. However, it is an overwhelming task to search through full text journal articles and find quality information needed by clinicians. We developed a method to rate journals for a given clinical topic, Congestive Heart Failure (CHF). Our method enables filtering of journals and ranking of journal articles based on source journal in relation to CHF. We also obtained a journal priority score, which automatically rates any journal based on its importance to CHF. Comparing our ranking with data gathered by surveying 169 cardiologists, who publish on CHF, our best Multiple Linear Regression model showed a correlation of 0.880, based on five-fold cross validation. Our ranking system can be extended to other clinical topics. PMID:25954382
Hydrodynamics of post CHF region
International Nuclear Information System (INIS)
Ishii, M.; De Jarlais, G.
1984-04-01
Among various two-phase flow regimes, the inverted flow in the post-dryout region is relatively less well understood due to its special heat transfer conditions. The review of existing data indicates further research is needed in the areas of basic hydrodynamics related to liquid core disintegration mechanisms, slug and droplet formations, entrainment, and droplet size distributions. In view of this, the inverted flow is studied in detail both analytically and experimentally. Criteria for initial flow regimes in the post-dryout region are given. Preliminary models for subsequent flow regime transition criteria are derived together with correlations for a mean droplet diameter based on the adiabatic simulation data
Povijesni pregled implementacije matematike i statistike u ekonomiju
Crnjac Milić, Dominika; Martinović, Martina
2012-01-01
U ovom preglednom članku dat ćemo kratki povijesni pregled implementacije matematike i matematičkih disciplina u kvantitativnu ekonomiju. Kronološki ćemo pokazati razvoj matematičkih metoda i njihovu primjenu u ekonomiji. Posebnu ćemo pozornost posvetiti ekonometrijskom razvoju.
Staff Association
2014-01-01
New offers : Discover the theater Galpon in Geneva. The Staff Association is happy to offer to its members a discount of 8.00 CHF on a full-price ticket (tickets of 15.00 CHF instead of 22.00 CHF) so do not hesitate anymore (mandatory reservation by phone + 4122 321 21 76 as tickets are quickly sold out!). For further information, please see our website: http://staff-association.web.cern.ch/fr/content/th%C3%A9%C3%A2tre-du-galpon
Renal and cardiac function during alpha1-beta-blockade in congestive heart failure
DEFF Research Database (Denmark)
Heitmann, M; Davidsen, U; Stokholm, K H
2002-01-01
The kidney and the neurohormonal systems are essential in the pathogenesis of congestive heart failure (CHF) and the physiologic response. Routine treatment of moderate to severe CHF consists of diuretics, angiotensin-converting enzyme (ACE) inhibition and beta-blockade. The need for control...... of renal function during initiation of ACE-inhibition in patients with CHF is well known. The aim of this study was to investigate whether supplementation by a combined alpha1-beta-blockade to diuretics and ACE-inhibition might improve cardiac function without reducing renal function....
Directory of Open Access Journals (Sweden)
Samyshkin Y
2013-01-01
Full Text Available Yevgeniy Samyshkin,1 Michael Schlunegger,2 Susan Haefliger,3 Sabine Ledderhose,3 Matthew Radford11IMS Health, Health Economics and Outcomes Research, London, United Kingdom; 2Marketing Specialty Care, 3Medical Department, Takeda Pharma AG, Pfäffikon, SwitzerlandObjective: Chronic obstructive pulmonary disease (COPD represents a burden on patients and health systems. Roflumilast, an oral, selective phosphodiesterase-4-inhibitor reduces exacerbations and improves lung function in severe/very severe COPD patients with a history of exacerbations. This study aimed to estimate the lifetime cost and outcomes of roflumilast added-on to commonly used COPD regimens in Switzerland.Methods: A Markov cohort model was developed to simulate COPD progression in patients with disease states of severe, very severe COPD, and death. The exacerbation rate was assumed to be two per year in severe COPD. COPD progression rates were drawn from the published literature. Efficacy was expressed as relative ratios of exacerbation rates associated with roflumilast, derived from a mixed-treatment comparison. A cost-effectiveness analysis was conducted for roflumilast added to long-acting muscarinic antagonists (LAMA, long-acting ß2-agonist/inhaled corticosteroids (LABA/ICS, and LAMA + LABA/ICS. The analysis was conducted from the Swiss payer perspective, with costs and outcomes discounted at 2.5% annually. Parameter uncertainties were explored in one-way and probabilistic sensitivity analyses.Results: In each of the comparator regimens mean life expectancy was 9.28 years and quality-adjusted life years (QALYs gained were 6.19. Mean estimated lifetime costs per patient in the comparator arms were CHF 83,364 (LAMA, CHF 88,161 (LABA/ICS, and CHF 95,564 (LAMA + LABA/ICS respectively. Adding roflumilast resulted in a mean cost per patient per lifetime of CHF 86,754 (LAMA + roflumilast, CHF 91,470 (LABA/ICS + roflumilast, and CHF 99,364 (LAMA + LABA/ICS + roflumilast
Effects of Microencapsulated Phase Change Material (MPCM) on Critical Heat Flux in Pool Boiling
International Nuclear Information System (INIS)
Park, Sung Dae; Kim, Seong Man; Kang, Sarah; Lee, Seung Won; Seo, Han; Bang, In Cheol
2011-01-01
Thermal power is limited by critical heat flux (CHF) in the nuclear power plant. And the in-vessel retention by external reactor vessel cooling (IVR-ERVC) is applied in some nuclear power plants; AP600, AP1000, Loviisa and APR1400. The heat removal capacity of IVR-ERVC is also restricted by CHF. So, it is essential to get CHF margin to improve an economics and a safety of the plant. There are some typical approaches to enhance CHF: vibrating the heater or fluid, coating with porous media on the heater surface, applying an electric field. The recent study related to the CHF is focus on using the nanofluid. In this paper, the new approach was investigated by using the microencapsulated phase change material (MPCM). MPCM is the particles whose diameter is from 0.1μm to 1000μm. The MPCM consists of the core material and the shell material. The core material can be solid, liquid, gas or even the mixture. The solid paraffin is the best candidate as the core material due to its stable chemical and thermal properties. And the shell material is generally synthesized polymer of about several micrometers in thickness. The most interesting feature of the MPCM is that the latent heat associated with the solid-liquid phase change is related to the heat transfer. When the MPCM is dispersed into the carrier fluid, a kind of suspension named as microencapsulated phase change slurry (MPCS) is formed. The study on the MPCS was conducted in field of both the heat transfer fluids and energy storage media. It is inspired by the fact that the latent heat can serve distribution to the additional CHF margin. The purpose of this work is to confirm whether or not the CHF is enhanced
Energy Technology Data Exchange (ETDEWEB)
Suh, Kune Yull; Kim, Yong Hoon; Kim, Seong Joong; Lee, Seung Dong [Seoul National University, Seoul (Korea)
2002-03-01
Experiments were performed to measure the CHF and the critical power and to investigate the heat transfer mechanism in the narrow gap with 2D slice test sections. Test parameters in this study included the gap size of 1, 2, 5, and 10mm and the system pressure from 0.1 to 1.0 MPa. The CHF was measured for the distilled water. Results of this study may be summarized as follows. 1) In the narrow gap size of 1 and 2mm, the CHF occurs at the bottom and propagates upwards as the inclination angle relative to gravitational force increases. 2) Dryout is the limiting heat transfer mechanism in the 2D sliced experiments, and the CHF reaches 80-90% of the 3D CHFG value. 3) In the narrow gap size of 1 and 2mm the CHF values lie on the order of 104 kW/m2, while in the gap sizes of 5 and 10mm the CHF values have an order of 105 kW/m2. 4) The flow visualization study revealed that the shape of bubble is elliptic and the hydrodynamic bubble diameter exceeds the size of 20mm. 5) In analyzing the CHF with the inclination angle of the heated surface in the narrow gap size of 1 and 2mm, there exists a transition angle in the vicinity of 20-30 .deg.. From the region of the inclination angle of 0 .deg. C to 20 .deg. C or 30 .deg. C, the dryout mechanism may be directly applicable. On the contrary the transition angle is not conspicuously seen in the gap sizes of 5 and 10mm in which dominant mechanism is closer to pool boiling. 27 refs., 29 figs., 8 tabs. (Author)
Franchising, moderní metoda vstupu na trh
Ramsová, Iveta
2011-01-01
My work deals with the franchising as a modern method of market entry. My work is divided into two main parts. The first part is about the meaning of the word franchising and his different types and possible forms of expansion of franchising to foreing markets. I also analyze the possible advantages and disadvantages of a particular company Mistic. The second part shows the application of franchising to specific company Mistic. On this part is supplemented by advantages and disadvantages of t...
Influenza infection and heart failure-vaccination may change heart failure prognosis?
Kadoglou, Nikolaos P E; Bracke, Frank; Simmers, Tim; Tsiodras, Sotirios; Parissis, John
2017-05-01
The interaction of influenza infection with the pathogenesis of acute heart failure (AHF) and the worsening of chronic heart failure (CHF) is rather complex. The deleterious effects of influenza infection on AHF/CHF can be attenuated by specific immunization. Our review aimed to summarize the efficacy, effectiveness, safety, and dosage of anti-influenza vaccination in HF. In this literature review, we searched MEDLINE and EMBASE from January 1st 1966 to December 31st, 2016, for studies examining the association between AHF/CHF, influenza infections, and anti-influenza immunizations. We used broad criteria to increase the sensitivity of the search. HF was a prerequisite for our search. The search fields used included "heart failure," "vaccination," "influenza," "immunization" along with variants of these terms. No restrictions on the type of study design were applied. The most common clinical scenario is exacerbation of pre-existing CHF by influenza infection. Scarce evidence supports a potential positive association of influenza infection with AHF. Vaccinated patients with pre-existing CHF have reduced all-cause morbidity and mortality, but effects are not consistently documented. Immunization with higher antigen quantity may confer additional protection, but such aggressive approach has not been generally advocated. Further studies are needed to delineate the role of influenza infection on AHF/CHF pathogenesis and maintenance. Annual anti-influenza vaccination appears to be an effective measure for secondary prevention in HF. Better immunization strategies and more efficacious vaccines are urgently necessary.
Bubble induced flow field modulation for pool boiling enhancement over a tubular surface
Raghupathi, P. A.; Joshi, I. M.; Jaikumar, A.; Emery, T. S.; Kandlikar, S. G.
2017-06-01
We demonstrate the efficacy of using a strategically placed enhancement feature to modify the trajectory of bubbles nucleating on a horizontal tubular surface to increase both the critical heat flux (CHF) and the heat transfer coefficient (HTC). The CHF on a plain tube is shown to be triggered by a local dryout at the bottom of the tube due to vapor agglomeration. To mitigate this effect and delay CHF, the nucleating bubble trajectory is modified by incorporating a bubble diverter placed axially at the bottom of the tube. The nucleating bubble at the base of the diverter experiences a tangential evaporation momentum force (EMF) which causes the bubble to grow sideways away from the tube and avoid localized bubble patches that are responsible for CHF initiation. High speed imaging confirmed the lateral displacement of the bubbles away from the diverter closely matched with the theoretical predictions using EMF and buoyancy forces. Since the EMF is stronger at higher heat fluxes, bubble displacement increases with heat flux and results in the formation of separate liquid-vapor pathways wherein the liquid enters almost unobstructed at the bottom and the vapor bubble leaves sideways. Experimental results yielded CHF and HTC enhancements of ˜60% and ˜75%, respectively, with the diverter configuration when compared to a plain tube. This work can be used for guidance in developing enhancement strategies to effectively modulate the liquid-vapor flow around the heater surface at various locations to enhance HTC and CHF.
Directory of Open Access Journals (Sweden)
Yu. А. Bunin
2017-01-01
Full Text Available Atrial fibrillation (AF, being both a cause and a consequence of chronic heart failure (CHF, occurs with it significantly more often than in the general population. Prevention and treatment of AF in patients with CHF has its own specifics and presents certain difficulties for practical physicians of various specialties. The article presents a modern view of primary and secondary prevention of AF in patients with CHF and a critical analysis of international recommendations on the use of various antiarrhythmics and not antiarrhythmic drugs, anticoagulants and non-drug treatments in these patients. Based on the analysis of a number of studies, it has been shown that in patients with AF and CHF, the sinus rhythm control strategy has no advantages over the rate control strategy. The review also examines the possibilities of drug therapy in rate control strategy in CHF, depending on the size of the left ventricular ejection fraction, as well as indications for interventional prophylaxis of the AF paroxysms. At the same time, it discusses some questions about the choice of tactics for management of patients with AF and CHF, electrical and pharmacological cardioversion and prevention therapy, features of AF treatment in certain diseases and syndromes. The article also presents a critical evaluation of interventions in the treatment of AF, such as catheter ablation of AF, catheter ablation of additional routes and destruction of the AV node in combination with the pacemaker implantation.
Kane, P M; Murtagh, F E M; Ryan, K; Mahon, N G; McAdam, B; McQuillan, R; Ellis-Smith, C; Tracey, C; Howley, C; Raleigh, C; O'Gara, G; Higginson, I J; Daveson, B A
2015-11-01
Patient-centred care (PCC) is recommended in policy documents for chronic heart failure (CHF) service provision, yet it lacks an agreed definition. A systematic review was conducted to identify PCC interventions in CHF and to describe the PCC domains and outcomes. Medline, Embase, CINAHL, PsycINFO, ASSIA, the Cochrane database, clinicaltrials.gov, key journals and citations were searched for original studies on patients with CHF staged II-IV using the New York Heart Association (NYHA) classification. Included interventions actively supported patients to play informed, active roles in decision-making about their goals of care. Search terms included 'patient-centred care', 'quality of life' and 'shared decision making'. Of 13,944 screened citations, 15 articles regarding 10 studies were included involving 2540 CHF patients. Three studies were randomised controlled trials, and seven were non-randomised studies. PCC interventions focused on collaborative goal setting between patients and healthcare professionals regarding immediate clinical choices and future care. Core domains included healthcare professional-patient collaboration, identification of patient preferences, patient-identified goals and patient motivation. While the strength of evidence is poor, PCC has been shown to reduce symptom burden, improve health-related quality of life, reduce readmission rates and enhance patient engagement for patients with CHF. There is a small but growing body of evidence, which demonstrates the benefits of a PCC approach to care for CHF patients. Research is needed to identify the key components of effective PCC interventions before being able to deliver on policy recommendations.
Measurement of effective renal plasma flow in congestive heart failure
International Nuclear Information System (INIS)
Tauxe, W.N.; Dubovsky, E.V.; Mantle, J.A.; Dustan, H.P.; Logic, J.R.
1981-01-01
In the management of patients with congestive heart failure (CHF), it is often desirable to have precise knowledge of overall renal function, including the effective renal plasma flow (ERPF). It has long been recognized that ERPF is diminished in CHF. Since glomerular filtration rate is often decreased to a much lesser extent, other noninvasive procedures such as the measurement of creatinine clearances may not be entirely suitable. ERPF determination by the single plasma sampling (SPS) method affords a rapid, simple, noninvasive, and economical technique that is quite accurate and reproducible. A SPS method has been well-tested in patients following renal transplantation plus a wide variety of nephrological disorders. We have been concerned whether the SPS method would be valid in volume expanded patients. In 28 determinations of ERPF in patients with CHF, and in five patients who did not have CHF, we have found the SPS estimation of ERPF to yield results that are not clinically significantly different from those obtained by the detailed compartmental analysis method. The volumes of 131 I-orthoiodohippurate (OIH) distribution were found to be somewhat higher in CHF than in controls, but fractional rate constants were proportionately lower so that intercompartmental flow rates and OIH concentrations were not different from controls. Therefore, the SPS estimation of ERPF is valid in patients with CHF and may be useful in monitoring the renal effects of various hemodynamic and pharmacological interventions. (orig.)
Directory of Open Access Journals (Sweden)
F. Lari
2013-05-01
Full Text Available BACKGROUND Chronic Heart Failure (CHF represents worldwide a clinical condition with increasing prevalence, high social, economical and epidemiological impact. Even if new pharmacological and non-pharmacological approachs have been recently used, mortality remains high in general population and quality of life is poor in these patients. DISCUSSION The association between CHF and sleep disorders is frequent but still undervalued: sleep apnoeas in CHF produce negative effects on cardiovascular system and an aggravation of prognosis. CPAP (Continuous Positive Airway Pressure is commonly used to treat sleep apnoeas in patients without cardiac involvement and it is also used in first line treatment of acute cardiogenic pulmonary oedema thanks to its hemodynamic and ventilatory effects. The addition of nightly CPAP to standard aggressive medical therapy in patients with CHF and sleep apnoeas reduces the number of apnoeas, reduces the blood pressure, and the respiratory and cardiac rate, reduces the activation of sympathetic nervous system, the left ventricular volume and the hospitalization rate; besides CPAP increases the left ventricular ejection fraction, amd the oxygenation, it improves quality of life, tolerance to exercise and seems to reduce mortality in patients with a higher apnoeas suppression. CONCLUSIONS These implications suggest to investigate sleep apnoeas in patients with CHF in order to consider a possible treatment with CPAP. Further studies need to be developed to confirm the use of CPAP in patients with CHF without sleep disorders.
EFFECT OF MITRAL REGURGITATION ON CHRONIC HEART FAILURE COURSE AND STRUCTURE-FUNCTIONAL HEART STATE
Directory of Open Access Journals (Sweden)
V. N. Larina
2009-01-01
Full Text Available Aim. To evaluate chronic heart failure (CHF course, functional and structural heart changes in patients with functional mitral regurgitation (MR of various degrees.Material and methods. A total of 104 outpatients (60-85 y. o. with CHF of functional class II-IV by NYHA and functional MR of I-II degrees and MR of III-IV degrees were included into the study groups.Results: Patients in both groups were comparable in sex, age, CHF duration, body mass index, systolic and diastolic blood pressure, clinical state by the clinical state scale, quality of life, anxious and depressive status. The majority of patients with MR III had significant left ventricle (LV systolic dysfunction (p=0,029, severe CHF course (p=0,034, received furosemide (p=0.004 and digoxin (p=0,004. They had significant increase in end-diastolic dimension (p<0,001, end-systolic dimension (p<0,001, left atrium (p=0,004, end-diastolic volume (p<0,001, end-systolic volume (p<0,001, pulmonary artery pressure (p<0,001, decrease in LV relative wall thickness (p=0,021 and LV ejection fraction (p<0,001. Patients of this group were hospitalized because of CHF decompensation and ischemic heart disease exacerbation more often (p=0,045.Conclusion. MR can be considered as one of sensitive predictors of LV geometry and function alteration in CHF patients and play an important role in symptoms development.